Commit Graph
204 Commits
Author SHA1 Message Date
serversdownandClaude Opus 5.5 c3746a6a01 docs(spec): park event deletion with the future call-in receiver
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:38:05 -04:00
serversdownandClaude Opus 5.5 eecabc76eb docs(plan): phase 1c -- the webapp by serial, and the wrong-series safeguards
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-28 23:20:26 -04:00
serversdownandClaude Opus 5.5 02d8517ebd docs(spec): park the MiniMate speed-ups, measured -- after 1c
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-28 23:16:50 -04:00
serversdownandClaude Opus 5.5 20ea61e0e9 fix(minimateplus): push_config_raw checks every block before the first write goes out (#46 review)
Review of b5037b0 (measured on 12 recorded SFM compliance reads): the read
keeps three escape bytes from its reply headers, so every real config image is
refused by write_image -- correctly, but only after 68 and 73 had been sent,
with a message saying nothing was.  All four blocks are now checked first; the
test feeds the block exactly as SFM's read produces it and asserts no frame is
sent (two went out without the check).

Config push stays unusable on purpose: fixing that read alone would let the
compliance encoder write some fields to the wrong bytes (e.g. 4,096 sps as
4,112) while the image still passes.  The rework -- logical read, encoding at
measured offsets with #48, a diff check, N pinned per SUB, an idle check, the
start/stop safeguards on POST /device/config -- is recorded in the spec and on
#46.  Start/stop frames are unchanged (verified byte-identical by the review).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 03:17:34 -04:00
serversdownandClaude Opus 5.5 329f7f2abb docs: retract the MiniMate write-frame model in place (#46)
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 02:54:56 -04:00
serversdownandClaude Opus 5.5 a7f581f66a docs(spec): the persist_download alignment follows what v0.32.0 shipped -- event-record times, the estimate guard
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 00:20:54 -04:00
serversdownandClaude Opus 5.5 98def4aae0 docs(spec): a stop starts a call-home on a unit with auto-call-home -- unmeasured on Series 3
Brian: stopping by command or keypad with ACH enabled makes the unit call home
and upload events + MLG, which can take minutes.  Fits UM20147's 0x01 after a
stop (10-25).  Owed: measure a MiniMate stop with ACH on, through the bridge.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 00:17:29 -04:00
serversdownandClaude Opus 5.5 d7e65f5d15 docs: MiniMate start through SFM verified on BE9441 -- the start/stop bench check is complete
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 00:13:37 -04:00
serversdownandClaude Opus 5.5 6f2acc79e6 docs(spec): owe persist_download an alignment with dev's waveform-time restamp before the merge
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 19:16:25 -04:00
serversdownandClaude Opus 5.5 1da3083665 docs: the MiniMate histogram and stop checks are done; start is still owed
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 19:10:04 -04:00
serversdownandClaude Opus 5.5 8acb9512a9 fix(minimateplus): size the 5A chunk cap from STRT, refuse a misread STRT, TERM only a tail
Follow-ups from the review of 887e75d (verdict: keep, with fixes; no critical).

- The cap: a caller's max_chunks (client.py passes 128) now bounds only a walk
  whose end is unknown.  With STRT it cut every event past ~66 KB short --
  2,545 of 63,500 archived histograms are bigger (the review's count, DL2).
  Strict raised; legacy sent a TERM for most of the event, or a bare ValueError.
- A STRT claiming less than one 0x200 chunk, or more than 4 MiB (a sanity bound,
  not a measured limit), is refused as a misread, in both modes -- once a bare
  ValueError and a 500.
- TERM is sent only for a true tail (< 0x200).  After an early end the legacy
  walk returns what arrived and sends none.
- build_5a_request wraps build_bw_frame; the old 5A helpers are marked
  superseded (kept for tests/test_5a_protocol.py) and their imports dropped.

Tests: all 8 recorded events (were 4) walk exactly as Blastware and rebuild its
own files; an end key holding escaped bytes; a 300 KB event past a 128 cap; both
misread-STRT refusals; the 1A frames BE9441 answered post-fix; the checksum
vectors retargeted.  Mutants the review saw survive (no STRT un-escape; a
standard-request escape revert) and 3 new ones are each caught.

Measured on the way: a reply's checksum is SUM8 of its unescaped payload,
748/748.  The 'S3 checksums frequently fail' note was the parser summing its
own kept escape bytes; noted, parser unchanged.

Docs: the crossing count corrected to four (events 1, 3, 5, 7); the remaining
stale 5A sections in CLAUDE.md annotated; the write-frame suspicion recorded as
inferred only.  No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 15:16:10 -04:00
serversdownandClaude Opus 5.5 6f31eca366 docs: the 64 KB page bug is fixed; the 5A 'non-standard frame' model retracted in place
CLAUDE.md: the KNOWN BUG entry marked fixed (887e75d) with what settled it, and
retraction notes under the 5A sections that described the misreading (partial
stuffing, offset_hi 0x10 raw, 11-byte params, metadata pages 0x1002/0x1004).
Series-III reference: a 2026-10-26 (3) row.  Spec: the MiniMate check updated.
Code comments that called the page bug open, updated; the adapter's struct.error
mapping kept as a defence, its message and test no longer naming the old bug.

Verified live on BE9441 the same day: all 8 events downloaded by serial, the 4
that cross a 64 KB page included, each whole and matching the unit's own peaks.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 14:44:11 -04:00
serversdownandClaude Opus 5.5 465bc704dd test+docs: SFM's MiniMate downloads are byte-identical to Blastware's; the 64 KB bug narrowed
Brian's Blastware downloads of BE9441's 20 events give ground truth.  SFM's
re-run downloads of events 0, 1, 3, 4 and 10 are byte-identical to Blastware's
own files; imported first through the watcher route, the same events download
as already_stored (no duplicate rows -- the unit's 0C and Blastware's file agree
on serial + timestamp).  Fixtures: Blastware's P00/Q10 (now asserted equal to
SFM's builds) and QZ0/T80, the two page-crossing events, as byte-exact targets.

The 64 KB page bug, narrowed by a read-only test walk: carrying the page byte
addresses the first chunk in page 0x12 (answered), but the next request carries
a raw 0x03 inside its params (counter 0x032c) and gets no reply.  Pages after
0x11 have such counters; 0x11 does not (event 1 skips 0x0000-0x05FF).  Needs a
Blastware wire capture of event 2 or 19 (recorded in CLAUDE.md, the Series-III
reference and the spec).  No code change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 12:15:50 -04:00
serversdownandClaude Opus 5.5 1ded70fcd9 docs: the MiniMate re-run -- every in-page event verifies; the 'reboot' was our bare 0x02 checksum
Series-III reference: a 2026-10-26 row (5A checksum escape, measured), and the
2026-10-25 row's guessed cause of the mid-download reboot (battery, firmware)
retracted in place -- it was our request.  CRLF kept.  Spec: the re-run, item
by item, and what is still owed.  CLAUDE.md: the phase-1b bullet brought up to
date.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 01:19:46 -04:00
serversdownandClaude Opus 5.5 f34f5c3376 test(minimateplus): pin the BE9441 bodies and files byte for byte, and the TERM's header skip
Re-review of 64273c0: nothing pinned the TERM skip -- a TERM cut one byte off
loses a byte after the END record, invisible to every decode and peak check.
Golden sha256 of both fixtures' bodies and written files (event 0's file is
byte-identical to the one SFM stored at the bench before any fix; event 1's is
the bench's 25,810 bytes plus the 2 recovered), and a TERM moved to 0x1002.
The clipped-blast test now sits two steps past full scale (32032 counts), so it
needs the carve-out.  Spec: the TOOL_VERSION reason corrected (no stored file
is affected); a MicL-only waveform is now refused -- failing safe, bench-check.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 19:01:36 -04:00
serversdownandClaude Opus 5.5 64273c07d3 docs(spec): the MiniMate fixes' review -- the changelog's operational note, a behaviour change, a bench-first item
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:52:42 -04:00
serversdownandClaude Opus 5.5 151782365b docs: restore the Series-III reference's CRLF line endings; the pre-trigger is 0.25 s
3898d03 rewrote docs/instantel_protocol_reference.md with LF endings (a 7,327-line
diff for 3 added lines).  CRLF restored; the file's real change is the 3 lines.
Also: BE9441's 21,504 samples are 5 s record + 0.25 s pre-trigger at 4096 sps,
not '+ 1 s' (reference row, fixture README, test comment).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:41:53 -04:00
serversdownandClaude Opus 5.5 3898d03236 docs: the first MiniMate bench run -- four bugs found, what remains of the check
Series-III reference: the 0x15 serial is a C string (BE9441's "BE9441\x00?"),
A5 replies echo their address at data[2:6] (metadata pages only on the
event-1 walk), the unit boots on serial-port open (banner ~3 s, answered 8.8 s
after a reboot's banner), one mid-download reboot, and 24 index entries vs 20
listed events (inferred: monitor-log entries).  Spec: the MiniMate check's
first run, item by item, and what is still owed.  CLAUDE.md: the phase-1b
"unproven" line retracted in place, with the four bugs and the re-run owed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:19:14 -04:00
serversdownandClaude Opus 5.5 5527fcd91f docs: correct today's overclaim -- the first *Micromate* commands, not the first ever
4b911b1 (and its subject line) called UM20147's start/stop "the first commands
this project originated".  The retracted CLAUDE.md line was always about Series
4: the minimateplus stack has sent Series-III writes (start/stop, config push,
erase, call-home config) since April 2026.  Narrowed in CLAUDE.md and the
Micromate reference.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 16:40:47 -04:00
serversdownandClaude Opus 5.5 4b911b1c0c docs: the first commands this project originated -- start/stop on UM20147
Bench, 2026-10-25, Brian's go per send: 0x96 acked in 464 ms and read back
monitoring at the first 2 s poll (during the sensor check); 0x97 acked in
116 ms, then 0x49 read a new value 0x01 for ~18 s (inferred: the unit's
call-home attempts after a stop) before idle; two stops to an idle unit acked
in 10 ms and changed nothing.  Retracts "no command has ever been originated"
in place in CLAUDE.md and the reference's untested list; answers the spec's
stop-while-stopped question.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 15:56:18 -04:00
serversdownandClaude Opus 5.5 b1c87ecccd docs(spec): what the phase 3 review left open, and why
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 19:36:36 -04:00
serversdownandClaude Opus 5.5 144d3779a1 docs(plan): phase 3 -- start/stop monitoring, the first live write, through the safety layer
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 00:47:12 -04:00
serversdownandClaude Opus 5.5 c6f7b5c031 docs(spec): the ring cool-down is test-first -- bench procedure for the ring path and retries
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 00:20:08 -04:00
serversdownandClaude Opus 5.5 75b7694983 docs(spec): phase-3 write preconditions and the measured Series-3 verdict
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 17:48:52 -04:00
serversdownandClaude Opus 5.5 36b6fada3f docs: say exactly what the phase-2 dry run and gate showed
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 17:48:35 -04:00
serversdownandClaude Opus 5.5 9ecf6e6a0c feat(bridges): mm_dry_run -- a write's planned frames from a live unit's reads; bench-checked on UM20147
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 17:29:00 -04:00
serversdownandClaude Opus 5.5 2a6acae259 docs(plan): Series-4 write path phase 2 -- encoder, opcode gate, write plans, dry run
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 00:14:30 -04:00
serversdownandClaude Opus 5.5 7a6c74266b docs: phase 1b re-review residuals -- bench scope gains the already-stored check, parked items corrected
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:59:25 -04:00
serversdownandClaude Opus 5.5 67a0fece34 docs(spec): park two more phase 1b items -- a lost 0C in a list, the walk retry
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:45:04 -04:00
serversdownandClaude Opus 5.5 a5ebe8d4b1 docs(spec): park the phase 1b review's open items; scope the owed MiniMate bench check
- New section "Left open by the phase 1b review (2026-10-21)", after the
  1a one: twelve one-line items, each naming the phase it matters to
  (retry re-running a whole download, last_used after a kept-line error,
  verified:null's two meanings, mic naming + the S4 0x0C mic denormal,
  500 detail text, the serial as a directory name, no server-level ring
  test, S3 stored record_type, a fresh S4 download's gaps, orphan files,
  same-second collisions, 423 Retry-After).
- The 1b bullets now give the owed MiniMate bench check's scope: a 3+
  event list (1F(browse) after 1E(arm) without 1F(arm)), a non-first
  event, a histogram (capture its 0C), an event past 64 KB (the named
  502), a stale id (no 5A), and a dropped reply via mm_link-style fault
  injection.
- The 1b "Download" bullet's "refreshes the row" is retracted in place:
  the final review changed it to "returns the row, writes nothing".

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:42:24 -04:00
serversdownandClaude Opus 5.5 ddb22d9624 docs(micromate): equal peaks across a histogram/waveform pair are real, not a list bug
Flagged in the phase 1b bench review; settled from the histogram file's own
interval data (5,021 counts vert = the waveform's 1.5581 in/s).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:13:41 -04:00
serversdownandClaude Opus 5.5 89a2a493fb docs: phase 1b bench-checked on UM20147 -- events by serial for both series
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:11:24 -04:00
serversdownandClaude Opus 5.5 ff7188a034 docs(plan): SFM device access phase 1b -- events for both series
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 16:45:50 -04:00
serversdownandClaude Opus 5.5 6b4161ddfb docs(spec): phase 1b decisions -- header-only MiniMate list, download stores, event_id
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 16:40:31 -04:00
serversdownandClaude Opus 5.5 89433c1fdb docs(spec): every phase lands on this branch; one merge to dev at the end
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 15:35:26 -04:00
serversdownandClaude Opus 5.5 e1af35e1d0 docs(spec): park the phase 1a review's minor findings in the spec
They were recorded only in the plan's scratch ledger, which is deleted
when the plan finishes.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:59:42 -04:00
serversdownandClaude Opus 5.5 080e8f4704 docs: serial parameter, settings/hangup endpoints, single-worker rule, cool-down prerequisite for 1c
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:45:33 -04:00
serversdownandClaude Opus 5.5 8eab5f9479 docs(plan): SFM device access phase 1a -- foundation plus identify/status/settings for both series
Ten tasks, test-first: the is_open fix, two client reads, core types, the
per-unit lock, both adapters, Series-4 sessions with ring safety,
DeviceAccess with the reaper and the contract tests, the endpoints, and a
read-only bench check on UM20147.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 19:10:15 -04:00
serversdownandClaude Opus 5.5 bbc6fe2a61 docs(spec): serial-less requests keep today's shapes; phase 1 splits into 1a/1b/1c
Nothing breaks between phases: the shared models apply when a request names
the unit by serial, and the legacy Series-3 path stays as it is until the
webapp (1c) and watch_unit.sh move over.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 19:03:03 -04:00
serversdownandClaude Opus 5.5 68cad4e2ab docs(spec): monitor logs are their own piece of work -- row 6 moves to the parking lot
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 18:54:24 -04:00
serversdownandClaude Opus 5.5 435c1978a0 docs(spec): park setup files and schedules as one open question
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 18:42:41 -04:00
serversdownandClaude Opus 5.5 90171996d6 docs(spec): say plainly what 'no PC-side setup library' means
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 18:38:56 -04:00
serversdownandClaude Opus 5.5 3215c17e37 docs(spec): one user experience for both series -- the guiding principle, applied
Brian's principle: talking to a Series 3 or a Series 4 unit is identical for
the user; only the serial prefix and each model's settings differ, and the
adapters absorb the rest.

Five places the draft broke it, now fixed: units are named the same way
(serial + address, no-serial kept only as a legacy Series-3 path); one set
of series-neutral response models with series-only fields under `detail`;
one opaque event_id for both; a uniform 501 "not supported for Series N
yet" instead of missing routes; and the webapp brought into scope with the
same screens for both.  Adds an adapter table, contract tests that keep the
two adapters honest, and notes that existing Series-3 response shapes move
to the shared models (the webapp updates with them; Terra-View does not
call /device/*).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 18:33:48 -04:00
serversdownandClaude Opus 5.5 1c6aa04687 docs(spec): SFM Series-4 parity and a device safety layer -- design for review
Parity of jobs with Series 3 for regular comms and settings (identify,
status, settings, events, download, monitor log, start/stop, call-home
enable/disable, setup push); Series-4 emergency tools deferred.  A single
device-access layer: series from the serial prefix, identity confirmed
before any write, a per-unit lock, an 0xA2 opcode guard, read-back
verification of every change, distinct error codes, and an audit table.
Series-4 sessions ("stay on the line") now; Series-3 sessions after a bench
test of MiniMate hangup/DCD behaviour.

Includes the fix list found in the 2026-10-19 inventory, the to-be-added
table, and the RX55 container idea as a parking-lot item.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 17:41:00 -04:00
serversdownandClaude Opus 5.5 a74d3c9b00 docs(series4): loading a setup is an exact replacement -- plus the prefs block, a checksum rule, and the firmware's own unit constants
23 more snapshots of UM20147, keypad-driven.

MEASURED: loading a .MMB replaces the active config byte-for-byte -- three
loads, each moving exactly the fields that differ, the loaded block identical
to the file's saved state, no load marker.  The setup name's spelling
(.MMB/.mmb) depends on whether it was saved or loaded.

MEASURED: job number [40:42], report flags [39] (0x02 job no., 0x08 scaled
distance; 0x01 unknown); distance [30:34] in metres and charge weight
[34:38] in kg, converted bit-exactly with ft / 3.2808 and lb / 2.21 -- the
firmware's own constants, not the textbook ones.  Scaled distance is not
stored.  Location confirmed at [144].

MEASURED: 0x08 is the preferences block (display units at content[31]),
not an event index; switching units moves nothing in 0x1A.  0x1A, 0x08 and
0x2E share one checksum rule (N = content[0:2]; CRC over [0:N-2] at
[N:N+2]); 0x2C has none.  0x2C session timeout is at [118:120], encoding
unknown; modem baud is in none of the six blocks.

CORRECTED IN PLACE: the 9-24 notes-label offset (0x8A -> 0x7A) and
channel-block start (0x06BC -> 0x06AC), both 16-byte slips.

RULE: never write modem baud or modem type remotely -- the remote link is
the modem port.

No codec, store or DB change; no backfill.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-19 17:30:37 -04:00
serversdownandClaude Opus 5.5 56b8aac4cb docs(series4): the 0x1A field map from a keypad pass -- a CRC, an edit buffer, and three mic blocks that are not channels
47 snapshots of UM20147 while settings were changed on its own keypad, one
at a time.  Every byte that moved is accounted for; nothing outside 0x1A
moved.

MEASURED (operator named setting + values): record mode [5] (01 Waveform,
02 Manual, 03 Histogram, 04 Combo -- S3's encoding, one byte later than the
S3 analogy put it), sample rate [6:8], histogram interval [8:10] s,
pre-trigger [12:16] f32 negative s (all four values), stop mode [17], record
time [18:22] f32, auto-stop [23], active-sensor and trigger-source bitmasks
[25]/[29], trigger level at channel +30 (geo in/s, mic psi).

MEASURED: the trailer is CRC-16/AUG-CCITT over content[0:2088] -- 47/47 and
a second unit.  Thor's write omits it, so it is read-side integrity, not a
write obligation.

MEASURED: blocks 1-3 are geophones, block 4 is the ACTIVE mic (a byte copy
of 5 or 6), 5 and 6 are the stored linear / SLM mic setups.  No separate
mic-type byte; block 4's +4:8 code is the type.  Promotes the 10-15 "+4
channel type" guess; retracts "+46:48 is a trigger-source flag" in place.

MEASURED: 0x1A reads the keypad's edit buffer live; discard reverts;
commit timing differs by widget (list / spinner / sub-window).

INFERRED, Series III: the 6-byte "stable anchor" sits exactly where Series
IV keeps pre-trigger (-0.25 s) + stop mode (Fixed).  An S3 unit in Auto
stop mode would lose it and decode no mode/rate/interval/record time.  Not
measured on S3; noted in instantel_protocol_reference.md, code untouched.

No codec, store or DB change; no backfill.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-17 02:22:00 -04:00
serversdownandClaude Opus 5 66171ffe36 docs(series4): the 0x1A channel blocks -- graded, because one of these is strong
and two are guesses

Six 48-byte channel blocks at content[1708], stride exactly 48: Tran, Vert,
Long, Mic, LMic, SMic.  (Mic is 3 chars, so a 4+-printable scan misses it and
the stride looks like 96 across that gap.)

RECORDED IN THREE EXPLICIT GRADES, because I wrote them in one voice first and
that is the failure mode this reference already carries retractions for -- the
0x0C float from a single sample, the cost model fitted to sub-1 KB responses,
offset detector v1.  All three were an interpretation presented with the
confidence of a measurement.

MEASURED, and the one worth having: channel+24 is a float32 BE reading
3.1030800342559814 on all three geo channels.  Divided by 10,000 that is
0.00031030800342559815 -- the documented _GEO_LSB_IPS to 1.1e-8.  It implies
10.0/3.10308 = 3.222605 V full scale, which at 10,000 counts/V gives 32226.05
counts, the documented figure exactly.

That is an INDEPENDENT confirmation of a number that until now rested purely on
statistical inference: _GEO_LSB_IPS was pinned by intersecting 991,415 rounding
constraints from Thor's own CSV exports.  The unit reports it directly.  Two
unrelated derivations agreeing to eight digits.  It is also almost exactly half
Series III's 6.206053 (ratio 1.99997, the residual being S3's rounded display
value).

Also measured: the units strings ("in."/"/s.", "psi"/"(L)", "dB"/"(A)") are
literal ASCII, and Tran/Vert/Long are byte-identical EXCEPT +47, which reads
0x01 on Tran and Vert and 0x00 on Long.

INFERRED (one setup, one unit): that +24 is the calibration constant rather than
another field holding the same number -- the arithmetic proves the number, not
the field's purpose; and that +47 is an enable or trigger-source flag.

GUESSED, explicitly flagged not to build on: +4 as a uint32 "channel type", from
six correlated observations in a single setup; and +8:24 as eight uint16 BE
values, where the split itself is an assumption.

TOOLING FIX in the same commit, from a real miss: the volatile baseline ran four
reads over eight seconds, so it never crossed a minute boundary and never saw
the minutes byte.  Five "changes" then came in a row that were just the clock.
Hours and the date would have slipped through identically.  An empirical noise
floor only catches what moves WHILE sampling, so 0x1C's known clock span
(content[2:10]) is now seeded regardless, and the report says which bytes were
observed versus seeded.  Memory-free is deliberately left unmasked -- it moves
only when the unit records, which is worth being told about.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-15 14:35:54 -04:00
serversdownandClaude Opus 5 711277131a feat(micromate): a config diff harness -- and the blocks turn out to be bit-stable
The Series III config map was built by changing one setting and seeing which
bytes moved.  Whether that method transfers to Series IV depended on an
unmeasured question: how much of a config block moves ON ITS OWN.  If a block
carries a clock or a counter, every diff arrives polluted and there is no way to
tell the real answer from the noise in a single pair.

MEASURED ON UM20147 (11.0BD), FOUR READS BACK TO BACK, NOTHING TOUCHED:

  0x1A compliance    2103 B    0 bytes moved
  0x2C call home      137 B    0
  0x2E trigger         39 B    0
  0x08 event index    101 B    0
  0x01 device info    163 B    0
  0x1C monitor status  59 B    2  (and those two are explained below)

Every config block held every byte still, so the method transfers directly and
needs no noise floor subtracted.  That was the open question.

scratch/mm_config_diff.py drives it: `volatile` establishes the floor, `snap`
saves a labelled read of all five blocks, `diff` reports changed runs with each
plausible field interpretation (u8/u16be/u32be/f32be) and reports any volatile
bytes separately rather than silently hiding them.

CORRECTION TO content[6] OF 0x1C, long recorded only as "NOT the hour": it is a
sub-second tick, ~4020 counts/second in steps of exactly 4, wrapping at 256 --
about a 64 ms period, consistent with the low 6 bits of a millisecond counter.
Consequence worth knowing: a 0x1C block is never byte-identical to itself, so
any "has the status block changed?" check answers yes ~15 times a second.
Compare named fields, never whole blocks.

I nearly recorded that byte wrong, and the trap is cheap enough to document:
sampled once per second it reads as a smooth monotonic counter at ~16/s with a
16-second wrap.  Twelve consecutive samples supported it.  It is aliasing -- a
64 ms counter read once a second is noise that happens to look tidy.  Measure a
counter back to back before trusting any rate from spaced samples.

Also: the settings do not have to be changed from THOR.  The unit's own keypad
works, which needs no Windows VM and does not contend for the modem's single
TCP session.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-15 12:28:40 -04:00
serversdownandClaude Opus 5 7645c91ae2 docs(series4): monitor-while-calling-home blocks erase, and THOR calls it success
Manual 11.4.4: a Micromate can call home WHILE IT CONTINUES TO MONITOR, or pause
monitoring and send.  UM12947 is on the former, which is why the captured session
logged "CANNOT DOWNLOAD MONITOR LOG" and "CANNOT DELETE ALL EVENTS -- The unit is
monitoring".

THOR REPORTS THAT SESSION AS "SESSION COMPLETED SECCESSFULLY" ANYWAY.  The
refusals are INFO lines.  From outside, a unit quietly accumulating looks
identical to one being managed correctly.

Correcting my own framing from earlier today: I flagged "Delete Events and Logs
from Unit = Yes" as a risk to the test data.  It is TMI's normal and necessary
fleet setting -- without it a unit fills up and re-offers every event on every
call.  A unit left on monitor-while-calling-home is the misconfigured one, and
drifts toward a full buffer by itself.

DESIGN CONSEQUENCE FOR SFM: a receiver cannot rely on erase to manage storage.
The erase can fail for a reason the unit considers normal, so the server-side
high-water mark is LOAD-BEARING rather than an optimisation -- it is the only
thing preventing a full re-download every session.  Series III's ach_state.json
(downloaded_keys / max_downloaded_key) is the pattern and has to carry over
deliberately.

Also a detectable fleet-health signal: "memory filling AND deletes refused" is
visible on every call from 0x06's event count and 0x1C's memory fields.  Worth
surfacing precisely because THOR calls it success.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-14 18:37:10 -04:00
serversdownandClaude Opus 5 08d2d31a09 docs(series4): a complete ACH session captured -- and 0xA2 is a loaded gun
MITM between UM12947's modem and THOR 1.5.0.29: 101 request frames, 101
responses, 0 bad checksums, 34,872 B of event data in 65 seconds.

EVERY COMMAND IN A REAL ACH SESSION IS ONE WE ALREADY IMPLEMENT -- POLL, SERIAL,
STORAGE_RANGE, MONITOR_STATUS, STATE, ARM_EVENT, EVENT_FIRST/NEXT, EVENT_RECORD,
BULK_DOWNLOAD -- except one.

SUB 0xA2 ENDS A CALL-HOME, AND COLLIDES WITH SERIES III'S ERASE.  The session's
final command is 0xA2 at offset 0xFFFF, answered 0x5D, and THOR's log at that
instant reads "StartMonitoringAfterCallhome / Switching unit back to monitoring".
So on series IV it means exit call-home and resume monitoring.

On SERIES III, 0xA2 -> 0x5D is CONFIRM ERASE -- the last step of
0xA3/0x1C/0x06/0xA2, after which the unit's memory is cleared.  Same opcode, same
response SUB, opposite consequence.  This is the most dangerous collision found
in this protocol: minimateplus and micromate already share a transport, and
sending 0xA2 to a MiniMate Plus to "end a session" erases it.  Any shared path
must dispatch on series before that byte goes near a wire.

It also corroborates the firmware string found by static analysis in September,
CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING.

TWO CORRECTIONS TO EARLIER ENTRIES OF MINE:

- 0x06 content[4:8] was recorded on 2026-10-01 as "9 on both units regardless of
  count -- a constant, not a count".  It reads 47 here, where THOR's log twelve
  minutes earlier reported "Monitor Log count: 45" on the same unit.  It is
  almost certainly the monitor-log count; both units reading 9 just meant both
  held 9 records.

- SUB 0x49 was recorded as 0x00 idle / 0x02 monitoring.  It reads 0x03 throughout
  this session, ten for ten -- a distinct in-call-home state.  Precisely why the
  rule is "test for non-zero": a client checking == 0x02 would call a unit
  mid-call-home idle.

Also softened the claim that mm_ach_server is "built on the wrong model".
ListenerAchTcp HAS now accepted a connection -- when nothing else holds the
modem's single session, the unit dials out and the listener takes it; when THOR
already holds a connection, the ring rides that instead.  Both paths are real.
The listener model is valid, it just loses the race against anything already
connected -- which explains every failed probe and relay attempt today as
contention rather than bugs.

And noted: THOR rewrites a unit's stored IP from the call-home source address, so
a relay silently poisons THOR's record of where that unit lives.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-14 18:35:38 -04:00