Interval size (k - 40), the stop (footer ts2), frequency = (sample rate
/ 2) / half-period with Blastware's words for N/A, >100 / >200 and
<1.0, and each interval's vector sum with its OORANGE rule. The old
fixed-512 frequency formula is retracted in place. CLAUDE.md and the
README roadmap follow: 34 of 88.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Blastware prints OORANGE for an interval's vector sum when it exceeds
the range in an interval where Blastware also clamped a channel: 17 / 17
DL2 cells, SFM's sum 10.01 .. 17.33 in/s (sqrt 3 x 10.005). The
saturation carve-out now covers intervals.Geo PVS in/s with that rule,
per interval, as it already did for PeakVectorSum. The 4 other cells
left mismatching sit 4e-6 past a rounding boundary (Blastware's
arithmetic is a hair lower) and stay mismatches.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Group B of the file-only decode, measured on DL2 2026-11-03:
- Frequency = (sample rate / 2) / half-period: 527,915 / 527,915 cells
at 1024 sps and 1,725 / 1,725 at 2048. #50: half_period_to_hz took a
fixed 512 and halved every 2048-sps frequency; it now takes the rate
(default 1024). Blastware prints 'N/A' for a half-period of 0, '>100'
('>200' at 2048) at 5 samples or fewer, '<1.0' below 1 Hz.
- Each interval's vector sum, sqrt(PVS^2) at the event's range:
771,354 / 771,354.
- Interval size: uint16 seconds at k - 40 (Series IV [8:10]).
- Stop: the footer's (2,995 / 2,999 sampled; 4 print a second earlier).
Event gains histogram_interval_sec, interval_half_periods, interval_pvs
and stop_time; the .h5 gains /intervals/half_period/<ch>,
/intervals/pvs_ips and a histogram_interval_sec attr. The decoder walks
a histogram once (histogram_codec.channels_from_records) and takes the
event's PVS from the same records. The checker compares each interval
column, number or Blastware's word; the test that pinned Tran Freq Hz
as blank now pins the match.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Protocol reference:
- D.6.8 (new): the identity block (SUB FE's: serial, firmware, DSP version,
calibration date and 'by', model; battery), the trigger-source bitmask
in the embedded event record, and the trigger settings (sources, stop
mode, per-channel levels, mic type) with their DL2 counts. The
histogram 'terminal tail' 9c 06 00 42 looks like 9c 06 00 + the
serial's B (inferred).
- D.6.6: recorded data vs report units vs unit peaks, with the
MiniMate Plus (s3.9.7) and Blastware (s4) manual sections. Where the
unit stores its own Microphone Units is unmeasured; a keypad test is
proposed.
- D.6.9 (was D.6.7): refreshed, 28 of 88.
CLAUDE.md 'Where things stand' and the README roadmap follow.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Both settings are documented: the unit's Microphone Units (MiniMate Plus
manual s3.9.7, keypad Right Arrow + Setups: psi(L) / dB(L) / Pa(L)) and
Blastware's report preference (Blastware manual s4, Preferences > Units
and Channel). The report follows Blastware's, as DL2's fleet-wide
switches showed. Where the unit's own setting is stored is unmeasured.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
K441LA17.IN0W's report says Units 'in/s and psi(L)' yet prints
MicTriggerLevel '125.0 dB(L)'. The value states its own unit, so that
is the one compared; the report's Units is the fallback. It was the
only MicTriggerLevel mismatch in DL2 (SFM's 0.005158 psi is 125.0 dB).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Group A of the file-only decode, every field matched against every DL2
report (2026-11-03):
- Identity block before the setup name, what the live read gets from
SUB FE: serial k-202, firmware k-147, DSP version k-138, calibration
date k-132 + 'by' k-128, manufacturer k-94, model k-72, firmware
minor k-193. Event.device_info (DeviceInfo gains calibration_date /
calibrated_by). Serial, Version and Calibration 69,983 / 69,983.
- Battery: uint16 hundredths of a volt at k-190 (Event.battery_volts).
69,729 exact; the other 254 are Blastware rounding half up.
- Trigger source: the two bytes between the embedded event record's
lead and fe 80, a bitmask (0x01 Tran 0x02 Vert 0x04 Long 0x08 MicL
0x200 Manual): 6,493 / 6,493. Event.triggered_by.
- Trigger settings in Series IV's 0x1A layout: sources bitmask k-19,
stop mode k-31 (0 = Fixed), each channel's float32 level at
label+30 (geo in/s, mic psi), mic type code at MicL+4 (2 = Linear
Weighting). Geo level 6,447 / 6,447, mic 4,403 / 4,403; Blastware
prints a level when its channel is a trigger source and the event
was not Manual. The mic level's dB uses 6895 Pa/psi (4,272 / 4,272
against 4,271 at 6894.757).
- .h5 attrs for all of them (additive).
- Checker: SFM's side reports the ten fields; the mic trigger level
follows the report's dB/psi. Carve-out
units-is-a-display-preference: dB or psi is Blastware's PC setting
when it wrote the report -- DL2's reports switch fleet-wide in 61
clean runs by write time, and no byte of the file separates them.
Two tests that pinned BatteryLevel / Calibration as blank now pin the
match.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
CLAUDE.md 'Where things stand' now says plainly how prod uses a paired
Blastware ASCII report (save_imported_bw overlays its peaks, notes,
sample rate and record time onto SFM's decode), that only report-less
events run on the decoder alone, and that the overlay is scaffolding to
retire at step 3 of the plan. The checker status is brought up to dev:
18 of 88 fields, the remaining groups A-F in the proposed order.
README roadmap: the same framing and progress.
Protocol reference:
- D.3.3: the footer is the file's last 26 bytes; footer[18:24] is not
fixed (retracted).
- D.6.1: STRT[18] picks the codec.
- D.6.3: the job number.
- D.6.5: the PVS^2 high word is non-zero above 1.28 in/s (retracted
'reads 0000'); the peak/PVS consistency check; Blastware's Number of
Intervals is the monitoring time / the interval.
- D.6.7: refreshed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Brian's account: units come back from calibration with the internal
battery unplugged, so a comms-test trigger before the date is set
carries the default. DL2 holds 17 such events on 6 units, all within
1995-09-01 12:02 .. 09-03 11:24.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Every DL2 file ends in a valid footer: 0e 08 and two valid times on
70,041 / 70,041. The decoder took the first '0e 08 + plausible year'
instead, and 14 files also hold an earlier record, ~1.1 KB before the
end, with the stop time followed by zeros:
- a histogram started at its own stop -- a day late on BE9558's daily
histograms (K558L9XP.FK0H: 2025-10-08 19:10:01 for Blastware's
2025-10-07 19:14:08); T003LCYV.JD0H got no time at all;
- a waveform lost its stop, so the trigger was never computed and the
stop was stamped instead (K440I4LG.JK0W: 11:14:12 for 11:14:08).
The last 26 bytes are now taken when they are a footer; otherwise the
old search stands unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Three causes behind the histograms the checker found decoding wrongly:
1. The file decoder tried the waveform codec first, whatever the record
type. It accepted BE9440 / BE9557 / BE17354's 2018 5 s histograms and
returned ~5x too many 'samples' (K440HDXX.XH0H: SFM 44,504, Blastware
6,976). The codec now follows STRT[18] (0x46 / 0x0A on 70,041 /
70,041 DL2 files); only an unknown type falls back to trial order, and a
chosen codec that fails is a decode problem rather than a silent switch.
2. The sub-minute layout check required each record's 'zero word' to be
0000. It is the high word of the interval's PVS squared, non-zero above
1.28 in/s, so a one-block histogram with a loud interval was not
recognised (T193KR5M.X90H, K440HA3C.JM0H, R352HFZ7.530H decoded to
nothing). The check is now the measured relation peak <= PVS <=
sqrt(3) * peak, which holds on 34,502,955 / 34,502,955 DL2 sub-minute
intervals. The no-terminal-tail trim uses the same test. Two test
builders wrote PVS bytes no real record has (one still in the retracted
little-endian layout); they now write peak^2 in the measured layout, and
the retraction test keeps a legacy builder of its own.
3. Checker carve-out interval-count-is-duration: Blastware's Number of
Intervals is (stop - start) / interval from the footer times, and its
own interval table lists one block fewer when the unit never wrote the
last minute. SFM matches the table (T193KSWP.FF0H: 2,880 vs 2,850).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The setup block has Series IV's 0x1A layout here too: report flags at
k - 9 (bit 0x02 = job number shown) and the number, uint16 BE, at k - 8,
kept while switched off. The flag matches Blastware's JobNumber on
2,997 / 2,997 DL2 events that print one and 66,986 / 66,986 that don't.
Every printed value is 1 and matches; hidden ones hold real numbers
(802, 1012, 1013, 622), so the value is only proven for 1.
- ProjectInfo.job_number_enabled / job_number, named as in
micromate.setup_block.
- write_event_hdf5 stores both as .h5 attrs when read (additive).
- The checker reports the number only when shown, and scores a number
only SFM shows as a mismatch. The old test that pinned JobNumber as
sfm_blank now checks only the ZC cases it also covered.
Not carried into the DB, the API or the PDF report yet (needs a column).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The pre-trigger float in an event file's setup block varies from event
to event on the same unit, often on the same day (BE18193: -0.25 and
-0.248 on 2026-08-21; 253-256 samples at 1024 sps, -0.002 to -0.249 s
at 4096 sps), and Blastware reports the same per-event value as
Pre-triggerLength. So it is the event's own pre-trigger, and the note
written earlier today overstated what the files say about #48: the live
1A holds the setting, so a missing anchor in a file says little about
whether the live read loses its anchor. #48 stays open.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
New Appendix D.6 records the bytes and DL2 verification for every field
SFM reads from a Blastware event file: record type STRT[18], the
recording-setup block (sample rate k-42, pre-trigger k-36, record time
k-30, the four notes), the geophone range (label+29), each histogram
interval's PVS^2, and the mic scale (0.25 Pa per count, dB offset
81.9384). None of these were written down outside code and issues.
Retracted in place:
- D.3.1's STRT[20] = record time: it is 00 on 70,041 / 70,041 DL2 files.
- the 2026-08-26 reading of sub-minute histogram records as little-
endian: big-endian from byte 5 since v0.32.0 (#47/#49), and the
'2-word tail' is the PVS^2. Also in CLAUDE.md.
Measured for #48 (files only): the 1A 'stable anchor' be 80 00 00 00 00
is the setup's pre-trigger -0.25 s plus 00 00. It is present only on
the 3,886 / 6,541 DL2 waveforms recorded at exactly -0.25 s, and on no
histogram. The live 1A read is still unmeasured.
CLAUDE.md: Where things stand reflects the range fix on dev (6,524 /
6,524 waveforms exact); the 8x sensitive-range item and the MicL dB
item are marked resolved in place.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
In the setup's channel blocks, the byte 29 after each geophone label is
the range: 0x00 Normal (10 in/s), 0x01 Sensitive (1.25 in/s). It matches
Blastware's GeoRange on 70,042 / 70,042 DL2 events, all three channels
agreeing on every one (35 Sensitive). SFM's live 1A has the same byte
at label+33. SFM assumed Normal, so every Sensitive event's peaks,
vector sum and .h5 samples read 8x high.
- Event.geo_range (0 / 1, None when not read -- channels disagreeing,
an unknown value or a missing block -- with a decode_problems entry).
- decode_blastware_bytes scales peaks and the histogram vector sum by it.
- event_hdf5.write_event_hdf5: geo_range defaults to None = the event's
own, else Normal; an explicit argument still wins.
- waveform_store.save_imported_bw and scripts/backfill_sidecars.py stop
forcing 'normal', so imports and the backfill store the file's range.
The waveform_store line was agreed with the parity session, which owns
that file; its own branch keeps a geo_range parameter, defaulting to
None at its next dev merge.
- The checker's SFM side converts at the event's range and reports
GeoRange; tests that pinned the old 8x gap now pin the fix, and the
saturation carve-out is still tested against an 8x value.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
A Blastware event that reaches SFM without its ASCII report -- every DL2
event before 2025, and every event SFM downloads itself -- now carries
its sample rate, record time, pre-trigger, notes and event type, the
histogram vector sum the unit stores, and a mic reading at one count =
0.25 Pa. The new decode checker proves each against Blastware's own
_XML.XML reports for 70,042 DL2 events.
- CHANGELOG: Unreleased -> v0.33.0 with theme and Migration.
- TOOL_VERSION 0.33.0 (gates the backfill regeneration).
- pyproject, CLAUDE.md and README versions; README status entry and
roadmap (the Series-III codec item was long done; the file-only goal
added); CLAUDE.md 'Where things stand' brought up to v0.33.0.
Deploy: back up seismo_relay.db, then backfill_sidecars.py and
backfill_event_shape.py (~2 h on the NAS). No schema change, no
migration, event times do not move.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The checker caught 280 regressions in the first mic fix: every one a dB
value at count 129, where 20 log10(129 x 0.25 Pa / 20 uPa) = 124.149997
rounds to 124.1 and Blastware prints 124.2. Blastware's dB offset sits in
[81.9383, 81.9385] -- any value there matches its dB(L) on 1,729,252 /
1,729,253 DL2 intervals (the last printed '0.000'); exact 81.93820 rounds
count 129 down, and the old 81.94 misses counts 119 and 132. Single
precision does not explain it. psi keeps 0.25 Pa per count, which
matches every interval.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
SFM converted mic counts to psi with a '~0.5 psi full-scale' guess
(0.0125 / 32768 psi per count). Measured against 1,729,253 DL2
histogram intervals' 'MicL Peak' columns: one count is exactly 0.25 Pa.
count x 0.25 Pa matches Blastware's psi(L) on every interval, and
20 log10(count x 0.25 Pa / 20 uPa) its dB(L) on all but 17 exact
half-way cases.
- event_file_io: _MIC_FS_PSI -> _MIC_PSI_PER_COUNT = 0.25 / 6894.757
(3.626e-5 psi per count, was 3.81e-7). The event's mic peak in psi,
and with it the .h5 mic trace (event_hdf5 back-solves its scale from
that peak), come right on events with no report.
- waveform_codec.mic_count_to_db: the offset is 20 log10(0.25 / 20e-6)
= 81.938, not 81.94 -- the old value missed 49 of those intervals at a
rounding edge (count 119 printed 123.4, 81.94 gave 123.451).
The decoded count was always right: count 16 on K441LTON.900 is
Blastware's 106.0 dB.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Every histogram interval carries its peak vector sum SQUARED, uint32 BE
in 0.005 in/s units: bytes [21:25] of a standard block (long documented
as 'constant 00 00' plus 'purpose unknown'), the last 4 bytes of a
sub-minute record (the undecoded 'meta_var'). sqrt(stored) x 0.005 is
the Geo PVS Blastware prints: 1,668,073 / 1,668,074 standard and 34.5 M
sub-minute DL2 intervals checked against the _XML.XML reports.
SFM computed the event's PVS from each channel's interval peak, which
can come from different moments, and read high on 86% of DL2's
histograms (T004JTRF.ME0H: 1.782 against Blastware's 1.358). It now
takes the largest stored interval value. histogram_codec.interval_pvs
returns the per-interval series; records gain 'pvs_sq'. Waveforms are
unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
STRT[18] is the record-type byte: 0x46 on every one of DL2's 6,577
waveform files, 0x0A on every one of its 63,535 histograms. The decoder
read the type from the filename's last letter, so an event with no
Blastware name -- SFM's own downloads, the call-in path -- or a manual
download ('.QZ0') came out 'Waveform' whatever it was.
The filename is now a cross-check that logs a disagreement; the bytes
win. An unknown byte (Manual / Event / Combo never occur in DL2) is
record_type None with a decode_problems entry, not a guess.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
- A matching event that now fails outright is a regression: compare_runs
walks the previous run's matching rows, so a check that collapses to
one error row no longer hides every field it used to match. Counts
moved are taken over the events both runs checked.
- The default baseline is the newest completed run (run.json written) of
the same scope; a 2,000-event sample is no baseline for a full run.
changes.md names the previous run's scope.
- The PVS saturation carve-out now needs Blastware's OORANGE, a channel
Blastware clamped at SFM's ceiling, and SFM's sum within three channels
at the ceiling -- an unclipped Sensitive-range channel read 8x can no
longer let an 8x sum through.
- 'Fields fully matching' needs a match: an always-empty element proves
nothing. Events without a report are a line of their own.
- CLAUDE.md: histogram PVS described correctly; 35 sub-minute histograms
plus 2 one-minute no-mic ones, not '~37 sub-minute'.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
First full run over DL2's 70,042 report-paired events (22 min, --jobs 4):
every expectation the spec set holds. Setup and notes match everywhere;
geophone samples are exact on 6,491/6,524 waveforms across 2016-2026,
the other 33 being the 1.250 in/s range read 8x on SFM's Normal
assumption; every histogram is typed as a waveform without its filename
(#41); the three #53 files are the only waveform time mismatches. New
findings: histogram PVS, mic psi, mic dB on ~1,000 events, ~37
sub-minute histograms, 26 histogram start dates.
The #53 note is corrected in place: those files decode as waveforms with
Blastware's full sample count; only their time falls back to the footer
start. scratch/verify_bw_fields_against_xml.py is retired -- the
checker replaces it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Each run is diffed against the previous one (--compare-to, or the newest
other run in ~/dl2-archive/checker-runs): changes.md lists every
(event, field) that matched before and no longer does, how many now
match, and how each field's counts moved; summary.md leads with the
regression count. --file NAME checks one event and prints its table,
writing no run folder.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
summary.md for Brian: per field, events per verdict, how many fields
fully match, non-matches by event year, carve-out counts. details.json
for Claude: each non-matching (field, verdict) with the attribute values
its failures concentrate in (>= 10% of the failures; concentrated at
>= 95% of compared events) and example events, each with a one-event
re-run command. On a 2,000-event sample the event-type mismatches group
as 'type = Full Histogram, 1815/1815' -- #41, named by the report.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
check_s3_decode.py pairs each Series 3 event file with its _XML.XML
report (deduped by basename -- Sent/ mirrors the root), checks each in a
process pool, and writes results.jsonl.gz and run.json to a run folder
outside the repo. A missing report or any failure is one row for that
event; the run goes on. Partial runs by serial, year, type, field
prefix or random sample.
Timing: --sample 2000 --jobs 4 took 35 s on tmi-dev (~20 min projected
for all 70,042).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
A mismatch becomes 'accepted' only through a written carve-out whose
evidence does not rest on SFM's output. Saturation: Blastware clamps a
clipped channel to the range maximum and prints OORANGE, while the file
holds counts past full scale. SFM's value must sit at the ceiling
(r - 0.0006 .. r * 1.01), so a Sensitive-range event read 8x high on
SFM's Normal assumption stays a mismatch; a vector sum is accepted when
a clipped channel under it is at the ceiling. series_pairs() is now the
one place waveform rows and interval columns are paired.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Every field the report carries (bar its format version and Blastware's
file name), the notes in order, the job number, the channel list, every
waveform sample and every histogram interval column. Numbers match at
Blastware's printed precision, halves rounding away from zero; N/A and
empty text are no_reference; >100 needs SFM's above-range flag; OORANGE
is a mismatch unless a carve-out says otherwise. Waveform rows pair
cells with the channels still running, so channels that end early
(T438HGTZ.B30W) match, and any row-length disagreement is counted.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
decode_blastware_bytes with no filename and no report: the values SFM
produces today in Blastware's field names, its notes, channels and raw
counts, with its Normal-range assumption kept.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The reference for the Series 3 decode checker: scalars and value units,
channels, the job number, the user notes in order under their
operator-edited labels, waveform rows as printed (ragged where channels
end at different lengths) and histogram intervals. Seven real DL2
events as fixtures, each covering a case the comparison must handle.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Eight tasks: the XML report parser, SFM's side from the bytes alone, the
field-by-field comparison, carve-outs (saturation first), the parallel
runner, the summary and grouped detail report, run-to-run changes with a
one-event view, and the first full run checked against what is known.
While pinning the plan's test values on real files: T438HGTZ.B30W, called
"3 samples short" by the setup-field harness, matches Blastware exactly.
Its Tran, Vert and MicL end 3 samples before Long, and Blastware's own
sample table does the same -- its last three rows carry only the Long cell.
The harness compared Tran's length with the table's row count. The spec
now says so, and the plan compares samples row by row by running channel.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The first of four pieces toward SFM producing everything Blastware reports
from the event file alone: compare every field, sample and histogram
interval with DL2's 70,042 _XML.XML reports (2016-2026), report what
matches, what doesn't and what SFM can't produce yet, grouped for
diagnosis, run after run.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
- README roadmap, Ingestion gaps: a bulk importer for event files on disk,
parked -- one of the four ways events should reach SFM.
- CLAUDE.md: the 14,338 ASCII pairs were described as "back to 2018"; they
are all 2025-26 events. Corrected in place. DL2's Sent/ _XML.XML files
are Blastware's full event reports, samples included, for 70,042 events
back to 2016 -- the reference for proving SFM's file-only decode.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
verify_bw_fields_against_xml.py decodes each Blastware event file the way
ingest does, without a report, and compares sample rate, record time,
pre-trigger, sample count, the four notes and the job number with the
event's _XML.XML report -- Blastware's full event report, which DL2 kept
for 70,042 events back to 2016 (ASCII reports exist only for 2025-26).
Every disagreement counts against SFM; there is no carve-out list yet.
The first piece of the decode checker.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Without a paired ASCII report, a Blastware import stored no sample rate,
the record-type byte as its record time (every waveform read "70 s"), a
pre-trigger and sample count read from STRT bytes that are neither, and
blank notes (the reader stopped at the NUL after each label).
- The recording-setup block is found by structure -- 1c 08, the setup
name, NUL -- not by the name "Standard Recording Setup", which 37% of
DL2's files do not use. One match in each of 70,041 archive files.
- Sample rate (uint16 BE, name-42), pre-trigger (f32 BE, name-36) and
record time (f32 BE, name-30). A waveform's sample count is the
decoded count. A histogram gets a sample rate only: Blastware reports
neither a record time nor a pre-trigger for one.
- The setup name and the four user notes by position, as bw_ascii_report
reads them: the labels are operator-editable ("Seis. Loc:",
"Location:", "Project: ").
- STRT now yields only the waveform key.
Verified against Blastware's own _XML.XML event reports for the 70,042
DL2 archive events that have one (2016-2026): sample rate 70,042/70,042,
record time 6,524/6,524, pre-trigger 6,484/6,484, notes 70,042/70,042,
sample count 6,523/6,524 (one waveform the decoder ends 3 samples short;
separate). Events imported with an ASCII report are unchanged -- the
report still overlays.
Not changed: the waveform-time estimate still finds the record time by
the marker; moving it would add a validation constraint for 37% of files
and is to be measured first. The job number is not read yet (2,997
archive events carry one).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
SFM is the whole seismograph module and "SDM" is retired; the codec
library stays pure; lab tools leave the production image and are ported
into sfm/ when they become production tools; the call-in server becomes
SFM's front door; the repo becomes `sfm` after the parity branch merges.
The old section stays in place below the banner as history.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
README: the intro no longer calls the Series-IV binary codec 'on the roadmap';
a v0.32.0 status entry; the ingest and Database sections describe the restamp
and estimate rules; the NULL-timestamp roadmap item points at #52.
CHANGELOG: v0.32.0 dated 2026-10-27, when its content was final.
TOOL_VERSION comment: times come from the event record, not the name.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
The release had not shipped, so its entries are corrected in place: the theme,
the time-source entry (the embedded event record, not the filename), the
estimate guard, and a note that the deploy rehearsal stands (record and filename
agree on all 1,394 prod waveforms).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
Brings fix/waveform-time-from-record (f91949b, 6cfcd04, and a docs pointer): the
trigger comes from the event record the unit sends in its 5A stream, validated
strictly; a filename is only a cross-check; no validated record means a
flagged estimate that never overwrites, merges or duplicates a row. Real data,
no names: 7,961/7,961 waveforms on the record, 0 disagreements. Suite vs dev:
the same 16 failures, byte-identical reasons.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
Brian: keep an event whose time is only an estimate (no validated embedded
event record) -- never discard a measurement for want of an exact timestamp --
but it must not silently cause an overwrite, merge or dedup collision.
insert_events, for timestamp_source 'estimate' (_estimate_guard):
- never restamps (moves) a row;
- if its file (a Blastware name) is already stored under another time, writes
nothing -- no second row, the stored time kept;
- if a different event already holds that second, writes nothing -- the old
upsert would have written this event over that one;
- otherwise stores it, or refreshes its own row at the same second, as before.
Each refusal is a WARNING naming both sides; the file and sidecar (which says
'estimate' and carries the decode problem) are already in the store. A generic
upload name ('imported.bw') is not taken as identity.
Tests: each rule, an estimate on a free second kept, generic names, and an
import end to end (a corrupted record next to a different event's second).
3 mutants, each caught. Suite vs clean origin/dev: the same 16 failing tests,
failure reasons byte-identical; 582 passed vs 553.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
Brian's requirements: the instrument's data is the only time source; a filename
is a cross-check, never a fallback (an event SFM receives itself has none).
The record (found by reading a seismo_lab Inspector dump; Series-III reference
§7.8.9): 00 28 05 00 ?? ?? | fe 80 | trigger | stop, times dd mm yyyy(BE) 00 hh
mm ss. Measured on 7,935 waveforms (DL2 + prod store): exactly one candidate
validates in every file; trigger = Blastware's report 1,320/1,320, = filename
7,935/7,935, = the unit's 0C record 10/10.
Provenance (requirement 6, measured): in Blastware's download of 8 BE9441
events the record -- with 24 B before and 22 after -- occurs exactly once in the
unit's own A5 reply payloads; SFM-only downloads (no Blastware) carry it too.
It is instrument data, not Blastware's.
- _embedded_event_record(): every fe 80 before the footer is a candidate; it
counts only with the lead bytes, two well-formed times (zero byte zero),
footer ts1 <= trigger <= stop, stop = footer ts2 or a second before, and a
length matching the record time. Exactly one must count; none or several is
a decode problem, never a guess.
- Without one: the footer estimate, timestamp_source 'estimate', a
decode_problems entry, a WARNING. No filename fallback.
- A filename that disagrees is logged; the decoded time is kept. A paired
report fills in only without a validated record (apply_report_to_event, the
sidecar dict overlay, event_to_sidecar_dict) and is logged when it disagrees.
- decode_blastware_bytes(raw, name=None): no file or name needed;
save_imported_bw uses it (no temp file). Event gains timestamp_source and
decode_problems; the sidecar records both.
- Histograms unchanged (#51): their record (fe f5) is noted, not used.
Tests: raw bytes with no name (ZI0, 7 BE12844 oracles), a disagreeing name, each
validation rule alone, two valid candidates, no filename fallback, report
precedence, sidecar. 7 mutants, each caught. Real data, decoded with no name:
7,961/7,961 waveforms on the record, 0 disagreements with filename or report;
10,433/10,433 prod histograms unchanged. Suite: only the 16 known failures.
Open (reported, not changed): 3 DL2 files named as waveforms whose body the
waveform codec does not recognise keep the footer start, 4 s off, as on dev.
None in prod.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
Series-3 waveform times carry Blastware's own (from the filename), re-stored
events move their rows instead of duplicating, prod's ISO-dated reports are
read, mic-off / mic-on sub-minute histograms decode right (#47, #49), Micromate
.h5 samples are on Thor's own scale (#42). Plus the Series-4 live protocol,
read-only client and setup decode (no shipped code path yet) and the SFM
Diagnostics tab.
TOOL_VERSION 0.31.0 -> 0.32.0: the deploy owes backfill_sidecars.py --force
--reparse-txt, backfill_thor_events.py, backfill_event_shape.py (~2 h on the
NAS), rehearsed on prod's 2026-09-30 store snapshot -- see Migration.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
Brings fix/waveform-time-restamp (847900b, abb671a, 3948dc1): insert_events
restamps a re-stored event's row by its Blastware filename; a paired report's
ISO-dated event time is read and survives a backfill; a waveform's time comes
from its filename. Deploy rehearsal on prod's 2026-09-30 snapshot (11,827
files): waveforms 1,016 -> 1,394 of 1,394 on Blastware's exact time, every id
kept, no row lost or merged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
The review of this branch measured (and I re-measured) that the binary's
trigger -- ts2 minus the record time, from 1e76d08 -- is a second off on 260 of
prod's 1,394 waveforms (2026-09-30 snapshot): 199 late, 61 early. A Blastware
filename encodes Blastware's own time to the second: it equals the report's
Event Time on 81/81 prod and 1,249/1,249 DL2 report-paired waveforms.
The cost of the second was real, not cosmetic:
- events is unique on (serial, timestamp), and on BE9558 the 61 early
waveforms land on their histogram twin's second -- a fresh import wrote each
waveform over its histogram's row (888 files -> 827 rows on dev);
- the release backfill would have moved 161 prod rows that v0.31.0 already had
exactly right a second off.
Same-second collisions across all 11,827 prod-snapshot files: 61 with the
binary's times, 0 with waveform names. Histograms keep the binary's ts1: their
name is Blastware's start time too (13,089/13,089) and ts1 runs a second early
on 97% of them, but with both on Blastware's times a waveform and its
histogram share a second 209 times -- the key cannot hold that. Correcting
histogram times needs the key changed; not here.
- blastware_file.blastware_filename_time(): the inverse of
blastware_filename(), V10.72 'AB0' names only, None for anything else.
- read_blastware_file(path, *, name=None): a waveform takes the name's time;
save_imported_bw passes the upload's real name (it reads a temp file).
- insert_events' restamp matches only Blastware names (every unnamed upload is
'imported.bw', so two events could share it) and, of several copies, moves a
reviewed one with a time first (review items M1, M2).
Tests: the decoder (documented names, encoder round trip, other names), a
waveform's name time, a temp-named read, histograms unchanged, the twin
collision on BE9441's own ZI0 (binary 14:23:43, Blastware 14:23:42), and both
review items. 5 mutants, each caught. Suite: only the 16 known failures.
Codec-library change: TOOL_VERSION to be bumped at release. No schema change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
Measured 2026-10-26. A sub-minute histogram block is [00][segment][ctr LE][0a]
(5 bytes), then one record per interval of BIG-endian peak / half-period pairs
per channel, then 0000 and one more word, then a 7-byte trailer. A record is 20
bytes with the mic and 16 without (4 x channels + 4); the standard 32-byte block
is the same thing holding one record. The last block is short, not padded: it
holds only the intervals recorded and ends on 9c 06 00 42.
#47: a mic-off histogram (16-byte records) decoded to nothing, so a Blastware
import carried no histogram data and SFM's download check would refuse it.
BE9441's K441LTOK.QZ0 (2 s, 22 intervals; fixture) now matches its Blastware
export on 66/66 peaks and 66/66 frequencies.
#49: the old reader took the mic-on records as little-endian from byte 6 -- the
same bytes shifted by one, identical while every high byte is zero. It also
required byte 5 to be 0 (the first record's Tran peak high byte) and read the
last block at full stride, trimming what it overran.
Regression over every DL2 histogram with a Blastware ASCII export (13,089
files, interval counts + every geo peak, frequency and mic dB): old reader
13,087 exact, new 13,089. The two the old one got wrong were one interval each:
K440KZP4.560H #4764 (Long half-period 1 read as 257, mic peak 389 as 133) and
M462KZUD.6R0H #145 (mic peak 6 read as 262).
Walk: blocks follow by block_ctr + 1, or the next segment every 256 blocks; the
last block is bounded by its terminal tail; with no terminal tail the old
trimming rule remains as the fallback. Mic-off records give m_peak None and an
empty MicL channel, as a mic-off waveform does. Inferred, not yet seen in a
file: mic-off 1-minute (28-byte) and 15 s / 5 s mic-off strides.
Not fixed here, noted on #47: half_period_to_hz assumes 1024 sps (512/hp); the
2048-sps histogram's frequencies are 1024/hp.
Operational: a decoder change -- needs a TOOL_VERSION bump at release, then
backfill_sidecars.py + backfill_event_shape.py (~2 h on the NAS) to regenerate
stored histograms. No schema change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
The event-time fix makes a Blastware report's Event Time + Event Date
authoritative over the binary, which gives the trigger only to the second.
On prod's own data it never applied (measured on the 2026-09-30 store
snapshot, all 81 report-paired Series-3 waveforms):
- every one of those reports writes Event Date as ISO ('2026-08-14');
_parse_event_date read only 'August 14, 2026', so event_datetime was None
(Brian's own laptop writes the long form -- it follows the PC's settings);
- the sidecar's bw_report block never stored the event time, and
apply_bw_report_dict_to_event -- the backfill's overlay -- never set it.
The binary's trigger matched Blastware's printed time on 66 of the 81 and was
a second late on 15; 8 of those 15 hold the right time in prod today, so the
release backfill would have made them a second worse.
- _parse_event_date accepts ISO dates too (81/81 now parse to the time
Blastware printed; 0/81 before).
- _bw_report_to_dict stores event_datetime (additive key).
- apply_bw_report_dict_to_event applies it, as apply_report_to_event does.
Prod's sidecars were written by the old parser, so the deploy runs
backfill_sidecars.py with --reparse-txt to re-read the saved .TXTs.
Tests: both date forms, the round trip through the saved block, a block with
no time, and the backfill (--force --reparse-txt) on a prod-shaped row.
Suite: only the 16 known fixture failures.
Codec-library change (report parser): TOOL_VERSION to be bumped at release.
No schema or DB migration.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
The waveform event-time fix (a84a46e / 1e76d08, on dev since 2026-09-20)
changed what time a Series-3 waveform decodes to: the trigger, where v0.31.0
stamped the monitoring-session start -- hours off. events is unique on
(serial, timestamp), so re-storing an old event at its corrected time matched
nothing and inserted it a second time.
Measured 2026-10-26: files stored with v0.31.0 (prod's code), then dev's
backfill_sidecars --force -- the release's own deploy step -- gave every
waveform two rows, one at each time. N844LQHB.ZT0W (BE12844): 06:00:13 and
10:33:29, its false-trigger mark only on the wrong-time copy. A Blastware
re-forward of an old event would do the same with no backfill at all. Prod
has not run the new decoder, so it holds no duplicates yet.
insert_events now matches a row by its stored file first (serial +
blastware_filename; a Blastware name encodes the serial and the second): one
under another time is moved to the new time in place -- same id, review kept --
and the usual refresh follows. When a different stored file already holds the
corrected second, nothing moves and nothing is written; the old upsert wrote
this event's file and peaks over that other event's row. Rows with no stored
file are matched on time alone, as before.
Tests: the move (id, review, refresh), a different file, no file, the
collision, a duplicate already at the new time, and the release backfill end
to end on a v0.31.0-shaped row. Re-checked across versions: v0.31.0 import,
then this branch's backfill -- 5 real files, every row corrected in place, no
duplicates. Suite: only the 16 known fixture failures.
No schema change, no migration, no codec change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
Every idf-import .h5 converted Thor's raw geo counts with the MiniMate
body-codec scale, full_scale / _GEO_INT16_FS. A Thor count is
0.000310308 in/s (micromate.idf_file._GEO_LSB_IPS), so the float samples
disagreed with the event's own peak by a constant:
10/32768 (until 686ab6e, 2026-08-25) samples -1.65%
10/32000 (since) samples +0.71%
v0.30.0's LSB fix (726c2ce) never reached this path. It corrected the
decoder's peaks, which were already right in the DB, sidecar and h5
peak attrs. The sample arrays go through the shared .h5 writer instead.
write_event_hdf5 now takes geo_ips_per_count. save_imported_idf and
backfill_thor_events (which replays the same bridge with its own write)
both pass _GEO_LSB_IPS. MiniMate callers are unchanged.
Measured: all 8 thor-idf fixtures (4 IDFW + 4 IDFH, 24 channels) go from
max|sample| / peak = 1.00706 to 1.00000 through the real ingest path.
Operational consequence: no schema change, no migration, TOOL_VERSION
not bumped here. Existing idf-import .h5 files keep the wrong scale
until regenerated: scripts/backfill_thor_events.py (--force, or bump
TOOL_VERSION at release), then backfill_event_shape.py, because the
offset detector reads these samples. Series-3 files are unaffected.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Folded into the existing Unreleased sections.
Added: MicromateClient.get_setup() (verified line by line against UM20147's
screen), micromate.setup_block.crc_ok() for 0x1A/0x08/0x2E, the config diff
harness, and the decoded setup in mm_client_check.
Changed: the 0x1A field map; channel blocks 4/5/6 are the active mic and two
stored mic setups; 0x1A reads the edit buffer and a load replaces it
byte-for-byte; the unit's own conversion constants (3.2808, 2.21); 0x08 is
preferences; the geophone scale confirmed from the unit's config; the 0x1C
sub-second tick; the never-write-modem-baud rule; two corrected 16-byte slips;
and the Series III anchor hypothesis, flagged inferred with no code change.
Fixed: the watcher overwriting previous sessions, and two stale bench-tool
labels.
Migration stays None -- additive modules only, no codec/store/DB change, no
TOOL_VERSION bump, no backfill.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Closes the gap the 10-13 recap named: config blocks were fetched but barely
read. Two keypad passes on UM20147 (10-17, 10-19), every byte that moved
attributed to a setting the operator named, then the map turned into code.
MicromateClient.get_setup() reads SUB 0x1A once and returns a MicromateSetup
-- record mode, sample rate, histogram interval, pre-trigger, stop mode,
record time, auto-stop, active sensors, trigger sources, trigger levels, mic
type and level, job number, scaled distance, notes. Measured fields only.
Every value matched UM20147's screen.
Findings that shape what comes next:
1. ONE CHECKSUM RULE (CRC-16/AUG-CCITT) covers 0x1A, 0x08 and 0x2E -- a free
integrity check on every config read. Thor's write omits it; the unit
computes it, so it is not a write obligation.
2. LOADING A SETUP REPLACES THE ACTIVE CONFIG BYTE-FOR-BYTE, and 0x1A reads
the keypad's edit buffer live. The name is the only link between a file
and its contents, and even its spelling varies (.MMB / .mmb).
3. THE SIX CHANNEL BLOCKS ARE 3 GEOPHONES + THE ACTIVE MIC + TWO STORED MIC
SETUPS. Read the mic from block 4 only.
4. THE UNIT CONVERTS UNITS WITH ITS OWN CONSTANTS (ft / 3.2808, lb / 2.21).
Convert back with them or 45 lb reads 44.89.
5. 0x08 IS THE PREFERENCES BLOCK; display units live there and never touch
the stored setup values.
6. NEVER WRITE MODEM BAUD OR MODEM TYPE REMOTELY -- the remote link is the
modem port.
INFERRED, Series III, no code changed: S3's 6-byte "stable anchor" sits where
Series IV keeps pre-trigger + stop mode, so an S3 unit in Auto stop mode may
lose it. One Blastware capture in Auto mode settles it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
MicromateClient.get_setup() reads SUB 0x1A once and returns a MicromateSetup:
record mode, sample rate, histogram interval, pre-trigger, stop mode, record
time, auto-stop, active sensors, trigger sources, the three geophone trigger
levels, mic type and (linear) mic trigger, job number, scaled distance, and
the four notes. MEASURED FIELDS ONLY -- everything graded inferred or
unknown in the reference stays in .raw.
micromate/setup_block.py holds the decode as pure functions (no I/O), plus
crc_ok(): one checksum rule for 0x1A, 0x08 and 0x2E. A failed checksum
raises SetupChecksumError (a ProtocolError) unless verify=False; a short
block raises either way.
Two things the decoder gets right that a naive one would not:
- the mic comes from channel block 4 (the ACTIVE mic), never blocks 5/6,
which hold the stored settings of whichever mic is NOT fitted;
- distance and charge weight convert back with the unit's own 3.2808 and
2.21, so 45 lb entered on the unit reads 45.0, not 44.89.
TESTS: 69 new. 15 real fixtures (2,103 B each) -- 14 UM20147 reads from the
10-17/10-19 keypad passes, chosen so every field takes at least two values,
plus UM12947's read from Thor's 9-24 capture (other firmware line).
Expected values are what the operator read off the unit's screen, never the
decoder's own output. Fixtures force-added, per the tests/fixtures/
convention. Full suite 541 passed; the 16 pre-existing failures
(test_bw_ascii_report.py 15, test_event_file_io.py 1) are unchanged.
VERIFIED ON HARDWARE: bridges/mm_client_check.py now prints the decoded
setup; against UM20147 every line matched the unit's screen (Brian, 10-19).
Also: the scratch harness uses the library checksum and checks all three
blocks; mm_client_check's stale labels fixed (0x06 content[4:8] is the
likely monitor-log count, not "unexplained"; 11.0BD is no longer "the first
one this code has met").
No codec, store or DB change; no backfill.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
23 more snapshots of UM20147, keypad-driven.
MEASURED: loading a .MMB replaces the active config byte-for-byte -- three
loads, each moving exactly the fields that differ, the loaded block identical
to the file's saved state, no load marker. The setup name's spelling
(.MMB/.mmb) depends on whether it was saved or loaded.
MEASURED: job number [40:42], report flags [39] (0x02 job no., 0x08 scaled
distance; 0x01 unknown); distance [30:34] in metres and charge weight
[34:38] in kg, converted bit-exactly with ft / 3.2808 and lb / 2.21 -- the
firmware's own constants, not the textbook ones. Scaled distance is not
stored. Location confirmed at [144].
MEASURED: 0x08 is the preferences block (display units at content[31]),
not an event index; switching units moves nothing in 0x1A. 0x1A, 0x08 and
0x2E share one checksum rule (N = content[0:2]; CRC over [0:N-2] at
[N:N+2]); 0x2C has none. 0x2C session timeout is at [118:120], encoding
unknown; modem baud is in none of the six blocks.
CORRECTED IN PLACE: the 9-24 notes-label offset (0x8A -> 0x7A) and
channel-block start (0x06BC -> 0x06AC), both 16-byte slips.
RULE: never write modem baud or modem type remotely -- the remote link is
the modem port.
No codec, store or DB change; no backfill.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Brian's hypothesis from the end of the 10-17 pass: selecting a .MMB
repopulates the active config, so a single load moves every field that
differs between two setups -- a check of the whole map in one step.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
47 snapshots of UM20147 while settings were changed on its own keypad, one
at a time. Every byte that moved is accounted for; nothing outside 0x1A
moved.
MEASURED (operator named setting + values): record mode [5] (01 Waveform,
02 Manual, 03 Histogram, 04 Combo -- S3's encoding, one byte later than the
S3 analogy put it), sample rate [6:8], histogram interval [8:10] s,
pre-trigger [12:16] f32 negative s (all four values), stop mode [17], record
time [18:22] f32, auto-stop [23], active-sensor and trigger-source bitmasks
[25]/[29], trigger level at channel +30 (geo in/s, mic psi).
MEASURED: the trailer is CRC-16/AUG-CCITT over content[0:2088] -- 47/47 and
a second unit. Thor's write omits it, so it is read-side integrity, not a
write obligation.
MEASURED: blocks 1-3 are geophones, block 4 is the ACTIVE mic (a byte copy
of 5 or 6), 5 and 6 are the stored linear / SLM mic setups. No separate
mic-type byte; block 4's +4:8 code is the type. Promotes the 10-15 "+4
channel type" guess; retracts "+46:48 is a trigger-source flag" in place.
MEASURED: 0x1A reads the keypad's edit buffer live; discard reverts;
commit timing differs by widget (list / spinner / sub-window).
INFERRED, Series III: the 6-byte "stable anchor" sits exactly where Series
IV keeps pre-trigger (-0.25 s) + stop mode (Fixed). An S3 unit in Auto
stop mode would lose it and decode no mode/rate/interval/record time. Not
measured on S3; noted in instantel_protocol_reference.md, code untouched.
No codec, store or DB change; no backfill.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
`watch` saved every session as `watch-000..NNN`, so each run silently
overwrote the last. Harmless while those snapshots were clock ticks; data
loss once they were findings. Labels now default to `watch-MMDD-HHMM-NNN`
(`--prefix` overrides).
Each 0x1A change also prints its trailer check: CRC-16/AUG-CCITT over
content[0:2088], stored BE at content[2090:2092]. Measured on 47/47
snapshots of UM20147 plus UM12947's 9-24 capture; a mismatch means a short
or corrupt read, or a layout this does not assume.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
"Where things stand" said config decoding "needs a bench session varying one
setting at a time -- not desk work", which was true when written and now sends a
reader off to build tooling that exists. This is the same staleness that had
the file claiming micromate/ had no live client.
What it now says, because these are the things that cost time to rediscover:
- The harness is scratch/mm_config_diff.py and the baseline is already captured.
- THE METHOD IS VERIFIED VIABLE: all five config blocks are bit-stable, so any
byte differing between two snapshots IS the setting. That was the open
question about whether the Series III approach transfers at all.
- Start with SAMPLE RATE. A large distinctive power of two pins endianness in
one shot; a boolean toggle moves one byte 0 -> 1 and teaches nothing.
- The keypad works. No Windows VM, no contending for the modem's single TCP
session.
- `sg dialout -c` is required to open /dev/ttyACM0, because the group membership
exists in /etc/group but not in shells started before it was added -- AND THE
FAILURE LOOKS LIKE A DEAD UNIT, which is worth a line on its own.
- watch-001..005 on disk are clock ticks, not findings.
- channel+24 = 3.1030800342559814, independently confirming _GEO_LSB_IPS to
1.1e-8 and 32,226.05 counts exactly.
- The rest of that channel map is GRADED and the grades are load-bearing: +4
"channel type" and the +8:24 uint16 split are single-setup guesses, recorded
as guesses on purpose.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
and two are guesses
Six 48-byte channel blocks at content[1708], stride exactly 48: Tran, Vert,
Long, Mic, LMic, SMic. (Mic is 3 chars, so a 4+-printable scan misses it and
the stride looks like 96 across that gap.)
RECORDED IN THREE EXPLICIT GRADES, because I wrote them in one voice first and
that is the failure mode this reference already carries retractions for -- the
0x0C float from a single sample, the cost model fitted to sub-1 KB responses,
offset detector v1. All three were an interpretation presented with the
confidence of a measurement.
MEASURED, and the one worth having: channel+24 is a float32 BE reading
3.1030800342559814 on all three geo channels. Divided by 10,000 that is
0.00031030800342559815 -- the documented _GEO_LSB_IPS to 1.1e-8. It implies
10.0/3.10308 = 3.222605 V full scale, which at 10,000 counts/V gives 32226.05
counts, the documented figure exactly.
That is an INDEPENDENT confirmation of a number that until now rested purely on
statistical inference: _GEO_LSB_IPS was pinned by intersecting 991,415 rounding
constraints from Thor's own CSV exports. The unit reports it directly. Two
unrelated derivations agreeing to eight digits. It is also almost exactly half
Series III's 6.206053 (ratio 1.99997, the residual being S3's rounded display
value).
Also measured: the units strings ("in."/"/s.", "psi"/"(L)", "dB"/"(A)") are
literal ASCII, and Tran/Vert/Long are byte-identical EXCEPT +47, which reads
0x01 on Tran and Vert and 0x00 on Long.
INFERRED (one setup, one unit): that +24 is the calibration constant rather than
another field holding the same number -- the arithmetic proves the number, not
the field's purpose; and that +47 is an enable or trigger-source flag.
GUESSED, explicitly flagged not to build on: +4 as a uint32 "channel type", from
six correlated observations in a single setup; and +8:24 as eight uint16 BE
values, where the split itself is an assumption.
TOOLING FIX in the same commit, from a real miss: the volatile baseline ran four
reads over eight seconds, so it never crossed a minute boundary and never saw
the minutes byte. Five "changes" then came in a row that were just the clock.
Hours and the date would have slipped through identically. An empirical noise
floor only catches what moves WHILE sampling, so 0x1C's known clock span
(content[2:10]) is now seeded regardless, and the report says which bytes were
observed versus seeded. Memory-free is deliberately left unmasked -- it moves
only when the unit records, which is worth being told about.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
The Series III config map was built by changing one setting and seeing which
bytes moved. Whether that method transfers to Series IV depended on an
unmeasured question: how much of a config block moves ON ITS OWN. If a block
carries a clock or a counter, every diff arrives polluted and there is no way to
tell the real answer from the noise in a single pair.
MEASURED ON UM20147 (11.0BD), FOUR READS BACK TO BACK, NOTHING TOUCHED:
0x1A compliance 2103 B 0 bytes moved
0x2C call home 137 B 0
0x2E trigger 39 B 0
0x08 event index 101 B 0
0x01 device info 163 B 0
0x1C monitor status 59 B 2 (and those two are explained below)
Every config block held every byte still, so the method transfers directly and
needs no noise floor subtracted. That was the open question.
scratch/mm_config_diff.py drives it: `volatile` establishes the floor, `snap`
saves a labelled read of all five blocks, `diff` reports changed runs with each
plausible field interpretation (u8/u16be/u32be/f32be) and reports any volatile
bytes separately rather than silently hiding them.
CORRECTION TO content[6] OF 0x1C, long recorded only as "NOT the hour": it is a
sub-second tick, ~4020 counts/second in steps of exactly 4, wrapping at 256 --
about a 64 ms period, consistent with the low 6 bits of a millisecond counter.
Consequence worth knowing: a 0x1C block is never byte-identical to itself, so
any "has the status block changed?" check answers yes ~15 times a second.
Compare named fields, never whole blocks.
I nearly recorded that byte wrong, and the trap is cheap enough to document:
sampled once per second it reads as a smooth monotonic counter at ~16/s with a
16-second wrap. Twelve consecutive samples supported it. It is aliasing -- a
64 ms counter read once a second is noise that happens to look tidy. Measure a
counter back to back before trusting any rate from spaced samples.
Also: the settings do not have to be changed from THOR. The unit's own keypad
works, which needs no Windows VM and does not contend for the modem's single
TCP session.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
Folded into the existing Unreleased sections.
Added: bridges/mm_ach_server.py, flagged as implementing the listener path only.
Changed: the captured ACH session (101 frames, every command already
implemented bar one); the two call-home paths and what decides between them; the
0xA2 collision with series III's CONFIRM ERASE; monitor-while-calling-home
blocking erase while THOR reports success; THOR rewriting unit IPs from the
call-home source; and the CLAUDE.md refresh.
Fixed: mm_client_check misreporting its own request count, the ACH server
buffering its output and leaving modem chatter as a hex dump, and .gitignore
missing capture artefacts beside tracked bridge source.
TWO ENTRIES CORRECT THIS FILE'S OWN EARLIER TEXT, which is the part worth
reading: 0x06 content[4:8] was recorded here as "a constant, 9 on both units"
and is the monitor-log count; SUB 0x49 was recorded as two states and has three.
Migration stays None -- no codec, store, DB or schema change and no TOOL_VERSION
bump -- but the note now says explicitly that THE 0xA2 COLLISION IS DOCUMENTATION
RATHER THAN A FIX. minimateplus can already send 0xA2 as the last step of its
erase sequence, and nothing yet stops a future shared path confusing the two
meanings. A guard is outstanding, and a reader deciding whether this release is
safe deserves to know that.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
Closes the last protocol unknown. A MITM between UM12947's modem and THOR
1.5.0.29 captured a complete working ACH session: 101 request frames, 101
responses, 0 bad checksums, 34,872 B of event data in 65 seconds.
EVERY COMMAND IN A REAL ACH SESSION IS ONE micromate/protocol.py ALREADY
IMPLEMENTS -- POLL, BULK_DOWNLOAD, STATE, EVENT_RECORD, EVENT_NEXT,
STORAGE_RANGE, MONITOR_STATUS, ARM_EVENT, SERIAL, EVENT_FIRST -- bar one.
Three findings that change how a receiver must be built:
1. CALL-HOME HAS TWO PATHS, decided by who holds the modem's single TCP
session. If something is already connected, the unit's RADIO RING travels up
THAT connection; if nothing is, the modem dials out to a listener. THOR's
UnitWatchDogTimer reconnects continuously, so THOR usually holds the slot --
which is why probes and relays saw "connected, no reply" all afternoon. That
was contention, not a fault.
2. SUB 0xA2 ENDS A CALL-HOME ON SERIES IV AND IS CONFIRM ERASE ON SERIES III.
Same opcode, same 0x5D response, opposite consequence. minimateplus and
micromate already share a transport, so any shared path must dispatch on
series before that byte reaches a wire. This is a hazard in code that
already ships, which is the main reason this merge should not wait.
3. "MONITOR WHILE CALLING HOME" SILENTLY BLOCKS ERASE, and THOR reports the
session successful anyway. A receiver therefore cannot rely on erase to
manage storage -- the server-side high-water mark is load-bearing, and the
condition is detectable from event count plus free memory on every call.
Two corrections to entries made earlier this month: 0x06 content[4:8] is the
monitor-log count rather than a constant, and SUB 0x49 has a third state (0x03,
in-call-home) which is why that flag is tested for non-zero.
bridges/mm_ach_server.py implements the LISTENER path only and says so; the
poller half -- holding outbound connections and watching for the ring -- is the
next piece of work.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL