- CHANGELOG: Unreleased -> v0.34.0 — 2026-11-04, with the release theme
and a Migration section (schema re-key + overnight backfill that moves
every Series-3 histogram time by one second; rehearsed twice on a copy
of prod's 2026-09-30 snapshot).
- pyproject.toml, CLAUDE.md, README: 0.34.0 (README gains its status
entry).
- TOOL_VERSION 0.34.0: the codec changed, so the backfill regenerates.
Verified on dev before this commit: the full decode checker matches
pre-parity dev on every verdict of all 70,112 DL2 events (47 of 88
fields), group D part 1 ran clean on its branch, and the suite has only
the 16 known failures (1,566 passed).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Everything by serial for both series, the audited changes (start/stop,
call-home, settings), the MiniMate wire fixes (#46, the 64 KB page, the
settings read as content), the legacy config write retired, the benches.
Operational: additive schema only (device_commands), no TOOL_VERSION bump,
no backfill from this branch.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Everything by serial for both series (identify, status, settings, events,
download, start/stop, call-home on/off, settings change), live downloads
stored as the watcher stores them, the legacy config write retired.
Phase 4 benched 2026-11-03, phase 5 benched 2026-11-04 on BE9441 and
UM20147.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Both protocol references, the spec's bench section and CLAUDE.md record
the bench: every settings change acknowledged, read back and confirmed on
the unit's screen, both units restored byte for byte; the escaped-
checksum stray byte (fixed); a MiniMate's open setup menu writes its
whole-block copy back on Cancel or Save, losing a remote change; the
alarm write at channel +38; [26:28] re-set by the unit while monitoring;
the first Micromate setup push with the unit's CRC equal to SFM's; the
Micromate scheduler switch in none of the blocks SFM reads.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
From the 2026-11-04 bench:
- A MiniMate settings preview warns that a change is lost if someone is in
the unit's setup menu: a write sent with the menu open was acknowledged
and read back, then lost on Cancel or Save -- the menu writes its own
copy of the whole block back (measured both ways on BE9441).
- The two bytes after the MiniMate settings block went out as 00 00 and
the unit took them; the preview note says so instead of 'unmeasured'.
- A Micromate call-home plan no longer warns about 0x00 / 0x01: UM20147
took both, each way, on 11-03 and 11-04, matching its menu.
- read_waveform_data_raw drops the escaped-checksum's stray 0x10, as the
settings read does (it failed closed: the write's block check refused
203 bytes).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
S3_ALARM_WRITE_MEASURED = True. At the bench on BE9441, with Brian's go,
the alarm went 1.0 -> 1.5 -> 1.0 in/s: each write acknowledged, read back
as sent, and shown in the unit's own setup menu. The write moved exactly
channel +39 of the three geophone blocks (the f32 at +38), where the
event files put it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Every printed acceleration in DL2 bounds Blastware's g; together they
leave [386.2236, 386.2240] in/s^2, and 386.2238 fits 19,475 / 19,479
values. The other 4 are one odd file (O117I1NK.R70W, whose peak times
are also off) and one sample mismatch. That is 9.81 m/s^2 (386.2205,
19,423) plus an unexplained offset, as with the mic's fitted dB offset.
The 59 values 9.81 left were all one last digit high.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Group D, part 1, measured on 400 DL2 waveforms (2026-11-04):
- time of peak = (first peak sample - pre-trigger samples) / sample
rate, per channel including the mic: 1,197 / 1,197 geophone values
- the vector sum's time, the same on sqrt(T^2 + V^2 + L^2): 398 / 399
- peak acceleration = the largest |v[i+1] - v[i]| x sample rate / g,
with Blastware's g = 9.81 m/s^2: 1,190 / 1,197 (the standard 9.80665
gives 1,073). Blastware's manuals: 'subtracts two velocity readings
and divides the result by the elapsed time between them'.
PeakValues gains *_time_of_peak, pvs_time and *_peak_accel_g, filled
for waveforms only. The checker reports them. Displacement (84% with
the manuals' half-cycle integral) and ZC frequency (46%) are not shipped
yet -- Blastware does something more there.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Bench 2026-11-04, BE9441 live: frame B of a 1A read arrived one byte long,
ending in a lone 0x10. When a frame's checksum byte is itself escaped
(02 / 03 / 04, about one frame in 85) the parser keeps the escape's 0x10
and strips only the byte after it. The 12 recorded reads never hit it,
so the assembled block was 2,091 bytes and SFM refused it as 'monitoring'.
read_compliance_content now passes the lengths it asked for (1024, 1024,
42) and that one stray byte is dropped; any other leftover still fails
is_compliance_content. The trimmed read decodes exactly as the old
decoder read the same reply.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Since #51 a waveform and a histogram recorded in the same second are two
events (UNIQUE(serial, timestamp, record_type)). persist_download's
'already stored?' checks matched any row at the second and any row under
the letterless Blastware name both twins share, so a live download of
one twin was skipped as stored. Both checks now hold to the download's
own type, read from its file (STRT[18]; IDFW / IDFH); an untyped row at
that second, or a download whose type does not read, still counts as
stored. find_event_by_blastware_name takes an optional record_type.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Brings the checker's file-only decode work onto the parity branch so the
phase-5 bench runs on the code that will ship. One conflict, the CRLF
Series-III reference changelog: both kept, phase 5's row numbered
'2026-11-03 (5)' above dev's (4)/(3)/(2). test_event_ingest's live-
histogram dedup test asserted the stored row sits a second off the 0C
time -- the #51 bug, fixed on dev -- so its premise now reads the event's
own second; the dedup it tests still holds.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
The reference gains D.6.10: the histogram's embedded event record (lead
00 28 05 00, source 04 00, marker fe f5, start, stop) and the interval
and peak-time rules, with 'histograms stay on ts1' retracted in place.
CLAUDE.md 'Where things stand' records the new events key -- any lookup
by event needs the type -- and 47 of 88; the README roadmap follows.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
From the whole-branch review of phase 5:
- The preview's revision now covers the changes asked for, so a live
change must be exactly what was previewed (any API caller, not only the
page). It covers what the preview showed -- the settings block (and a
Micromate's setup name) -- not the blocks a write only echoes, which are
re-read at send and sent as read (a MiniMate's trigger block byte 5
differs by session, #46).
- The units' limits hold on the block that would result: a range, rate or
mode change alone can no longer leave a held trigger, alarm or record
time over them.
- Every MiniMate block read is logical, so push_config_raw no longer
unescapes again (a job number of 4098, 10 02, was refused at Send); the
preview runs the write's own block check, so a block it would refuse is
shown as blocked.
- A MiniMate's monitoring refusal says a stop makes it call in (spec).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
The Config tab by serial is now the unit's edit form, headed 'On the
unit <serial> -- read HH:MM' and built from the server's editable
fields. Preview runs a dry run and shows old -> new, notes and anything
that blocks the change; Send (confirm) sends exactly what was previewed,
with its revision, then shows what the unit now holds and re-reads it.
An edit after a preview disables Send until the next preview. The
by-host form loses its write button; the read stays. Logic in
device_routing.js (Node-tested), glue in sfm_webapp.js, no inline JS.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
DeviceAccess.change_settings refuses before any I/O a request with no
changes, a live change without its preview's revision, or no audit log,
then dispatches the series' change (never retried). The route returns
the preview (fields old -> new, warnings, blocked, revision) or the
result (fields old/new/now), statuses as the other changes, and marks
the cached by-host config dirty after a live change.
/device/config and /device/config/project now answer 410 with a pointer.
Deleted with them: MiniMateClient.apply_config / set_project_info and
the raw-offset _encode_compliance_config (#46 found it wrong), the
lab script poc_set_project.py and experiments.py's EXP6, both of which
wrote a live unit through it. Git keeps them.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Series3Adapter.settings reads the 1A block assembled into its 2,090
logical bytes and decodes it with micromate.setup_fields (a monitoring
unit's device-info answer is refused with 'stop monitoring first').
change_settings runs the shared change core: read the four settings
blocks, patch the settings block's fields, send Blastware's sequence
through push_config_raw with the event index, trigger and waveform blocks
as read, re-read. Refused before sending: monitoring, a value the unit
does not allow, a stale preview. push_config_raw's pre-check now raises
ImageRefused, so a refused image is audited as nothing sent.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
s4_change_settings runs the shared change core with a read-back verdict
for its state (as asked / unchanged / differs). It reads the active
setup's name (unstripped), the preferences, trigger and setup blocks and
the schedule; patches the setup through micromate.setup_fields; sends
THOR's setup push (0xDA 68 73 82 83 71 72, now enableable) once; reads
the setup back. Refused before sending: a monitoring unit, a value the
unit does not allow (422), a stale preview (SettingsChanged, 409), and --
shown as 'blocked' in the preview -- the factory setup, a schedule that
loads another setup, an unreadable schedule, or a block SFM has not seen
(ChangeRefused, 409). s4_settings carries the editable fields.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
MicromateProtocol.read_file: 0x94 + path, then 0x48 pages to an
all-zero reply -- THOR's frames byte for byte (UM12947, 2026-09-24),
including params[3] = 1 on 0x94 and params[7] = 1 on the first 0x48.
micromate.schedule parses the 260-byte records (two- and five-entry
schedules from THOR's captures) and names the scheduled starts that
would load a setup other than the active one, ignoring case. The
client gains the raw (unstripped) active-setup name and the prefs /
trigger / setup content reads a setup push sends back.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
With the start right, the rest of Blastware's histogram timing follows,
measured on a 2,000-histogram DL2 sample:
- each interval's printed time is its end, start + (i + 1) x interval,
capped at the stop: 2,308,524 / 2,308,524 rows
(event_file_io.interval_times)
- each of Tran / Vert / Long / PVS / MicL's peak date and time is that of
the interval holding its first maximum: 2,000 / 2,000 each.
The checker compares intervals.Time and the ten peak date/time fields.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The footer's start runs a second early on 97% of histograms. Each
histogram carries an event record like a waveform's -- lead 00 28 05 00,
source 04 00, marker fe f5, then start and stop -- and it holds
Blastware's Histogram Start and Stop on 63,490 / 63,490 DL2 histograms.
On all 63,500 there is exactly one, its start 0 or 1 s after the
footer's and its stop 0 or 1 s before; that is the validation rule.
Without a validated record the footer's start stands, as a decode
problem.
Ships with the unit + time + type key (ea2dfc2), without which a
waveform and its histogram at the same second would collide. Three
tests that pinned the old footer start (one said 'for now', pointing at
#51) now pin the record's, which equals the file's Blastware name.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
micromate/setup_fields.py: the fields an operator can change (record
mode, sample rate, interval, record time, geophone trigger, Series 3's
range and -- read-only until benched -- alarm, job number and its report
flag, the four notes by slot), the units' own limits from Instantel's
manuals, field-only byte patching (bit fields bit by bit; Series 3's
[26:28] as Blastware writes it; Series 4's CRC recomputed), the
read-back verdict compared by bytes, and the preview revision.
All 11 Blastware compliance writes reproduce from the block before them
(BE11529's first also shows Blastware re-rendering two mic levels
through its dB value; SFM echoes the unit's bytes); Series 4 keypad
fixtures reproduce pairwise.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Under the unit + time + type key, the test's untyped neighbour no longer
shared the imported waveform's key, so the waveform was stored as its
own row -- the neighbour untouched, which is what the test's name asks.
The guard's job is an estimate landing on another waveform's second, so
the neighbour is now a waveform. A companion test pins the case the new
key allows: an estimate beside a histogram at its second is stored
alongside it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The events table was UNIQUE(serial, timestamp): one event per unit per
second. A unit records a waveform and a histogram in the same second
legitimately -- 209 times in prod's 2026-09-30 store once histograms
carry Blastware's start -- so the key is now (serial, timestamp,
record_type). Agreed with Brian 2026-11-03.
- Migration 3 rebuilds the table from its own current definition with
only the key swapped, in one transaction: every column, row and id is
kept (Terra-View reads rows by id) and the indexes are recreated.
Migration 1's check no longer mistakes the new key for a missing one.
- The upsert, the estimate guard and the restamp match on the type too.
The restamp also re-types a file's own row in place: before v0.33.0 a
row's type came from the filename, and a re-import under the file's
own type must not add a second row.
- An untyped event still refreshes the untyped row at its second (a
UNIQUE key treats NULLs as distinct).
- scripts/repair_unknown_serials.py checks the new key.
No time changes yet: that is the next commit, and they ship together.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Unescape each 1A data frame, take data[11:], drop the one non-content
byte that starts every frame but the last: 2,090 bytes headed by
N = 2090, Series IV's 0x1A layout. Measured on BE9441's 10-26
recording (12 reads, both frame patterns); the read after each
Blastware write equals the image written. read_compliance_content is
strict (a missing frame raises) and unjudged (a monitoring unit's
device-info answer comes back for the caller to recognise).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Brian: use the actual unit limits, not what has been used in the past.
Trigger 0.005-10 in/s in 0.001 steps (capped by the range), record time
1-90 s (Micromate) or the MiniMate manual's 1 MB table by sample rate
(13 s in Histogram Combo), job number 1-9999. The read-back reports any
value a unit does not take.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Seven tasks: the Series 3 read assembly, one settings codec for both
series, the Micromate schedule read, each series' audited change, the
route (and the legacy write retired), and the page. Spans measured
from 75,958 Blastware reports. Bench after the final review, Brian's
go per send.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
A scheduled start loads the setup it names, so a change to another
setup would be undone at the next start: read schedule.dat and refuse
that case. Configurable work-hours recording, without THOR's scheduler
or setup files, is the agreed next project.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Interval size (k - 40), the stop (footer ts2), frequency = (sample rate
/ 2) / half-period with Blastware's words for N/A, >100 / >200 and
<1.0, and each interval's vector sum with its OORANGE rule. The old
fixed-512 frequency formula is retracted in place. CLAUDE.md and the
README roadmap follow: 34 of 88.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Brian's intent (UM6047's trigger, notes typos, the backup unit), the
flow, the first-version fields, and what is measured: Series 3's
compliance block has Series 4's 0x1A layout; a whole 1A read assembles
to the 2,090 bytes Blastware writes back (exact on both 10-26 writes);
Blastware writes 00 00 at [26:28] and a per-unit constant after the
block.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Blastware prints OORANGE for an interval's vector sum when it exceeds
the range in an interval where Blastware also clamped a channel: 17 / 17
DL2 cells, SFM's sum 10.01 .. 17.33 in/s (sqrt 3 x 10.005). The
saturation carve-out now covers intervals.Geo PVS in/s with that rule,
per interval, as it already did for PeakVectorSum. The 4 other cells
left mismatching sit 4e-6 past a rounding boundary (Blastware's
arithmetic is a hair lower) and stay mismatches.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Group B of the file-only decode, measured on DL2 2026-11-03:
- Frequency = (sample rate / 2) / half-period: 527,915 / 527,915 cells
at 1024 sps and 1,725 / 1,725 at 2048. #50: half_period_to_hz took a
fixed 512 and halved every 2048-sps frequency; it now takes the rate
(default 1024). Blastware prints 'N/A' for a half-period of 0, '>100'
('>200' at 2048) at 5 samples or fewer, '<1.0' below 1 Hz.
- Each interval's vector sum, sqrt(PVS^2) at the event's range:
771,354 / 771,354.
- Interval size: uint16 seconds at k - 40 (Series IV [8:10]).
- Stop: the footer's (2,995 / 2,999 sampled; 4 print a second earlier).
Event gains histogram_interval_sec, interval_half_periods, interval_pvs
and stop_time; the .h5 gains /intervals/half_period/<ch>,
/intervals/pvs_ips and a histogram_interval_sec attr. The decoder walks
a histogram once (histogram_codec.channels_from_records) and takes the
event's PVS from the same records. The checker compares each interval
column, number or Blastware's word; the test that pinned Tran Freq Hz
as blank now pins the match.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Protocol reference:
- D.6.8 (new): the identity block (SUB FE's: serial, firmware, DSP version,
calibration date and 'by', model; battery), the trigger-source bitmask
in the embedded event record, and the trigger settings (sources, stop
mode, per-channel levels, mic type) with their DL2 counts. The
histogram 'terminal tail' 9c 06 00 42 looks like 9c 06 00 + the
serial's B (inferred).
- D.6.6: recorded data vs report units vs unit peaks, with the
MiniMate Plus (s3.9.7) and Blastware (s4) manual sections. Where the
unit stores its own Microphone Units is unmeasured; a keypad test is
proposed.
- D.6.9 (was D.6.7): refreshed, 28 of 88.
CLAUDE.md 'Where things stand' and the README roadmap follow.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Both settings are documented: the unit's Microphone Units (MiniMate Plus
manual s3.9.7, keypad Right Arrow + Setups: psi(L) / dB(L) / Pa(L)) and
Blastware's report preference (Blastware manual s4, Preferences > Units
and Channel). The report follows Blastware's, as DL2's fleet-wide
switches showed. Where the unit's own setting is stored is unmeasured.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Brings be5bab4 and its history from the decode checker's branch: a Blastware
file's job number; decode_blastware_bytes choosing the codec by STRT[18] and the
histogram layout check by peak <= PVS <= sqrt(3) peak; the footer as the file's
last 26 bytes (no day-late histograms); docs (reference Appendix D.6, the
file-only status).
Conflicts, both kept whole:
- CLAUDE.md: this branch's 'Narrowed 2026-10-26' 5A block stays, followed by
dev's 'Open, not blocking' line (the 8x sensitive-range item struck out --
resolved by the file's range).
- docs/instantel_protocol_reference.md (CRLF, byte-safe): the change-log rows in
date order -- dev's 2026-11-03 and 2026-11-02, this branch's 2026-11-03
(call home), 2026-10-29 and 2026-10-27 (#46, this branch only).
Suite on the merged tree: 1399 passed, the 16 known failures.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Benched 2026-11-03 on UM20147 and BE9441 (each on its own modem, one send per
go): idle, a no-op, off and on all acked, read back and confirmed on each unit's
menu; UM20147 accepts 0x00 at [5]. Monitoring, neither series takes a change: a
MiniMate answers 0x2C with its device-info block, a Micromate acks and ignores
('Feature disabled while monitoring'). Series 4 [118:120] is a function of the
block's content -- XOR 0x6D7D per bit-0 flip on two units, not a nonce. A stop's
call-in reached THOR when the ring followed the ack. UM20147's clock is an hour
ahead (DST). Spec, both protocol references (Series III: a CRLF row), CLAUDE.md.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44