A fresh checkout of dev failed 10 tests, errored 3 and skipped 64: the
tests read 100 files that were only on the dev box. Recorded with an
audit hook over a full run: 100 files, 2.3 MB, out of 1.1 GB of
bridges/captures/ and 45 MB of histogram-extension-re/.
- Force-added in place: tests/fixtures/thor-idf (14), histogram-multi-
interval (2) and the one histogram-extension-re file read.
- Copied into tests/fixtures/example-events/ (10) and
tests/fixtures/captures/ (73, from bridges/captures/), and the tests
pointed there.
- The presence skips ('not on this machine', 'gitignored', 'fixture
missing') are gone: a missing fixture now fails instead of skipping.
The worktree now runs as the dev box does: 1,787 passed, 0 failed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
A fresh whole-branch review found four Important issues; three of its
Minors and one item it set aside were re-graded up. Each has a test that
failed first.
- A windowed timeline 500'd when a file came without its modified time
(Python 3.10 rejects the 'Z' of received_at). received_at is now
+00:00 and timeline times parse 'Z' too.
- On the clock-step day an event-triggered call-in moved the event into
the next session and lost the step. An event now joins the 'monitoring
started' record of its own file.
- A call-in whose records came first in another file (a cable download)
read 'nothing_new'. Each file now keeps its own call summary
(last_stop, no_file_stops) from when it arrived.
- Sessions and call-ins now carry record_ids / file_ids / file_id, the
shot report's proof (spec 5).
- A non-'started' record with no stop made the unit's timeline 500 for
good; it now opens a session whose end is unknown.
- A serial from a file's bytes (or a hint) could write outside the store;
only plain serials are used, and records with no serial are refused, not
dropped.
- Times with a UTC offset, an empty 'at', or a bad mtimes value gave 500s
(or stored half a request); they are now 400s, checked first.
- A missing call-in file made the gap after its Modem Exit read 'not
monitoring' for days. Files are numbered <serial><counter>; a gap
across a missing number is now 'records missing' (unknown). A long gap
after a call-in with no number missing is 'no restart after a call-in':
real outages on the DL2 data (BE6907 14 days from 2026-10-07; BE8081
over Labor Day 2019). Real fixtures BE6907 #899-#902 added.
- Docs: BE8081 did write one empty file (BE80811.MLG).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R9LdWawLzUxwewZGA1
scripts/import_mlg_dir.py imports every .MLG under a directory (files
with records first, then the empty ones, so each unit's serial is known
first; dry run writes nothing). scratch/check_mlg_vs_events.py matches
each Event Recorded record to an event file's footer (stop, flag word,
trigger source) in both directions, inside each unit's .MLG period.
Run on the dev box against DL2's 1,273 sample files (2026-11-13):
import: 1273 ok, 0 errors, 231 empty, 0 unresolved, 2180 records, 13 s
BE8081: 785 matched, 0 record-only, 0 file-only
BE6907: 6 matched, 5 record-only, 0 file-only
BE12844: 19 matched, 37 record-only, 0 file-only
every record-only one stops after 2026-08-25, where the DL2 copy ends;
the 4,303 footers of those three units' event files all pass their CRC.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R9LdWawLzUxwewZGA1
POST /db/import/mlg_file (per-file status; good files stored even when
another in the request is refused; each file's modified time as a JSON
form field), GET /db/units/{serial}/timeline (optionally windowed),
GET /db/units/{serial}/monitoring_at, GET /db/mlg_records, and
GET /db/mlg_files/{id} (the original, byte for byte, for printing).
Tested by calling the route functions directly: httpx is not in this
venv, so TestClient tests would skip silently.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R9LdWawLzUxwewZGA1
sfm/mlg_timeline.py builds, from a unit's stored records: sessions (with
how each ended, its events and its trigger level as logged), the gaps
between them and what each means (call-in, scheduled off, lost power,
stopped by a person, memory full), clock steps (a session starting
before the previous one stopped, as at the end of daylight saving), and
call-ins: delivered, no_file (a Modem Exit that left no file) and
nothing_new (an empty file). monitoring_at() answers monitoring /
not_monitoring / unknown, never claiming more than the records show.
Tested on real files, including BE8081's weekend: Battery Low Exit
Saturday 10:47, back Monday 12:47, two calls that left no file.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R9LdWawLzUxwewZGA1
sfm/mlg_ingest.ingest_mlg() is shared by the import route and the bulk
script. A file that is not whole, or with any record failing its
checksum, stores nothing. The serial comes from the file; for an empty
file (no serial inside) from the caller's hint, else the longest known
serial its <serial><counter> name starts with, else unresolved.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R9LdWawLzUxwewZGA1
Two new tables, created on first start (no migration):
mlg_files (one row per file received, deduped by name + sha256) and
mlg_records (one row per log record, unique on serial, start, stop,
flag word and trigger source; COALESCE on the stop, since an open
record's NULL stop is distinct to a UNIQUE constraint). The text is not
part of a record's identity: Blastware writes it, and two copies of the
same records differ there. WaveformStore.save_mlg keeps the original
file byte for byte under <serial>/mlg/.
Operational consequence: two new tables on first start; no migration,
no backfill.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R9LdWawLzUxwewZGA1
mlg_bytes()/write_mlg() rebuild all 12 fixture files byte for byte:
little-endian times, length-led records, each record's checksum. The old
blastware_file writer (big-endian times, a zero CRC at the wrong end, 308-
byte header) and the read_mlg stub are removed; nothing called them. No
re-export: event_file_io imports blastware_file, and mlg_file imports
event_file_io.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R9LdWawLzUxwewZGA1
minimateplus/mlg_file.py parses the measured format: an 18-byte prefix,
then length-led 292-byte records, each with a CRC-16/AUG-CCITT over
[0:288] stored little-endian. A record that fails its checksum is
returned flagged, never silently dropped. One shared CRC function
(minimateplus/crc.py) replaces micromate/setup_block's copy.
Fixtures: 12 real .MLG files (DL2's ACH folder + 3 bench files) in
tests/fixtures/mlg-11-9-26/, force-added.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R9LdWawLzUxwewZGA1
5dff54b listed file types; a Dockerfile, .jsonl, .gitignore or any type not
yet invented had no rule. .gitattributes now defaults every file to
`text=auto eol=lf` (Terra-View's rule), marks the binaries, and keeps
tests/fixtures/** -text. Renormalizing under it changes no file.
tests/test_line_endings.py fails if a tracked file outside the fixtures is
stored CRLF, or if the rule stops covering new text types, fixtures or
binaries. Its CRLF detector, pointed at the fixtures, finds all 38.
Suite: 1,711 passed, 0 failed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
S3FrameParser kept the 10 of a checksum sent as `10 02/03/04` as the reply's
last data byte. It now takes the pair: 7,747 / 7,747 recorded replies check,
272 of them with an escaped checksum. Fixes the 1C battery/memory misread
(419.84 V on 12 of 760 recorded status replies) and the 2C call-home read; the
5A file builder's own compensation is removed with it, and pre-fix .a5.pkl
frames are converted on load (A5_PICKLE_VERSION 2). checksum_valid now sums
the unescaped payload.
Conflict: the reference's changelog table (dev's own 2026-11-06 row); #58's
row kept as 2026-11-06 (2). Suite on the merge: 1,693 passed, 0 failed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
They were two stale tests, not broken code:
- tests/test_bw_ascii_report.py (15) read its Blastware ASCII reports
from decode-re/5-8-26/ at the repo root, removed when the fixtures
moved to tests/fixtures/decode-re-5-8-26/. At the real path all 27 of
its tests pass. The same stale path made a report-pairing test in
test_event_file_io.py skip silently; it now runs and passes.
- test_save_imported_bw_without_report_works_unchanged (1) expected a
sample-less event's PPV to be 0.0. Since fa9d3cd (2026-05-20) the
decoder deliberately leaves peaks unknown (None) so a backfill never
writes zeros over real peaks; the sidecar-level check now says so.
Its main assertion -- no bw_report block without a report -- is
unchanged and covered nowhere else.
Full suite: 1,620 passed, 0 failed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The ~20 histograms with one mic interval off were Blastware printing
the same number in both mic columns of a row: I145HKWT.DY0H row 672
reads 95.92 under psi(L) and dB(L) (count 5: dB), S353K894.OE0H rows
106 and 608 read 0.000 under both (count 2: psi). SFM's count agrees
with the neighbouring rows and with the other column. mic-units-mixed
now covers the interval mic columns too; a column names its own unit.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Blastware's dB(L) / psi(L) labels do not hold for the mic on every
report (DL2, 2026-11-09):
- the mic peak carries its own <Units>, which 7 reports set to dB under
a psi Units line and 3 the reverse: the checker now reads the peak in
its own unit;
- a mic sample table has no unit of its own and need not follow the
line (S353JTHU.DT0W prints dB under psi): the checker reads it from
its cells -- a mic dB value is never under 60, psi never over 1;
- some reports mix the two inside one column: K441L9IN.OT0W prints psi
'0.000' for counts of 1 to 3 in a dB table. Carve-out
mic-units-mixed accepts a mic field when every cell SFM disagrees
with is SFM's own value in the other unit: 19 DL2 events (14 sample
tables, 5 peaks); a cell matching neither stays a mismatch.
Not a decoder change: SFM's mic data were right. Checker run
20261109-141808: 78 of 88 fields, 0 regressions; no mic peak or mic
sample table mismatches left.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The 81.9384 offset came from a window fitted on histogram intervals,
[81.9383, 81.9385], which was too high. Every count Blastware printed
in DL2 -- 1,704 in waveform sample tables, 520 in histogram intervals,
494 histogram peaks -- leaves [81.9382058, 81.9382266]: count 129
(124.2) bounds it from below, 463 (135.2; 81.9384 prints 135.3) and 677
(138.5) from above. One offset serves all three printing paths; no
count prints two ways once range-1 mics and psi-formatted tables are
set aside. Fixes the mic samples and peaks that sat one digit off at a
rounding edge. The old window's comment is kept, retracted in place.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Inside an interval the rule is the event's: a peak past 2,000 units
(the mic in counts) is Blastware's OORANGE, and the interval's vector
sum is OORANGE when any geophone is. DL2 (2026-11-09): numeric up to
1,846 (geophones) / 1,414 (mic), OORANGE from 2,001; vector sums 16 / 16
OORANGE with a geophone over, 2,862 / 2,862 numeric without.
event_file_io.over_full_scale(count, channel); the checker renders those
interval cells as OORANGE. The saturation carve-out compares SFM's own
words properly (_differs): an OORANGE from SFM never counts as
saturation, and an OORANGE equal to Blastware's is not a difference.
Its interval tests run on the numeric values it used to see.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The mic's channel block carries a range byte at the geophones' offset
(label + 29, reference D.6.4). At 1 each count is an eighth, 0.25 / 8
Pa: set on 7 DL2 events, all of them Blastware's values divided by 8,
and on none of the other 70,026 -- independently of the geophone range
(28 events have Sensitive geophones and a range-0 mic). SFM read those
7 mics 8x high: K557J1XQ.GF0W is 79.4 dB(L), not 97.5.
Event.mic_range; the decoded mic peak (and so the .h5 mic samples, whose
scale is the peak's) and the checker's mic conversions follow it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
A channel is over range when the unit's own peak (its summary's min /
max) passes 2,000: 32,000 counts, full scale, on either geophone range;
the mic in counts. Blastware prints OORANGE for that channel's peak,
for the vector sum when any geophone is over, and its "Out of Range"
line when the mic is (DL2, 2026-11-09): numeric up to 1,991 / 1,933,
OORANGE from 2,001; the vector sum is OORANGE on all 43 events with a
geophone over and on none of the 38 whose vector sum alone passes
10 in/s -- the open "vector sum alone" carve-out was never needed.
PeakValues gains tran/vert/long/mic/pvs_over_range. The checker matches
OORANGE by the flag, and calls a flag against a printed number a
mismatch. Clipped events that the saturation carve-out used to accept
now match outright; the carve-out stays as the fallback for a file
without the unit's summary, and its guards are tested that way.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Blastware prints one Monitor Log line per event: the footer's start and
stop, then words for the footer's flag word [18:20] -- 69,983 / 69,983
DL2 lines, character for character (2026-11-08):
0x0001 Event Recorded 0x0010 Timer Stop
0x0002 Keyboard Exit 0x0020 Modem Exit
0x0004 Remote Exit 0x0200 Battery Low Exit
0x0008 Selfcheck Passed 0x0800 Memory Full Exit
One line sets Modem and Timer and prints Modem, so the higher bit wins
(the order of the others is inferred). Footer [20:22] is the event
record's trigger source again (69,983 / 69,983); [22:24] is zero; [24:26]
is not a common CRC-16 or sum.
Event.monitor_log: MonitorLogLine(start, stop, flags, description), read
only when the file's record chain is whole, which proves the footer.
The checker compares it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
S3FrameParser summed its payload with the kept `10` of each `10 02/03/04`
still in, so checksum_valid was False on about a third of good replies (the
old "S3 checksums frequently fail" belief). SUM8 of the unescaped payload
is the unit's checksum on 7,747 of 7,747 recorded replies; the test pins it
on the 2,509 in the committed October fixtures (62 with an escaped checksum),
which also proves #58's split of data from checksum on real replies.
Nothing decides on checksum_valid; seismo_lab's display stops crying wolf.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
A MiniMate sends a checksum of 02, 03 or 04 as `10 X`. S3FrameParser kept
both bytes and _finalise took only the last as the checksum, so the frame's
data ended in a stray 0x10. It now takes the pair.
Measured on every recorded reply (60 captures, March to October 2026): SUM8
of the unescaped payload is the checksum on 7,747 of 7,747; 272 arrived
escaped, all valid as an escape pair.
What the stray byte did:
- 1C status: battery and memory are counted from the end; 12 of 760 recorded
status replies read 419.84 V / 251,654,656 bytes (6.76 V / 983,026).
- 2C call-home read: one byte long, refused as "monitoring".
- 1A, 09 reads: already trimmed (bench 2026-11-04); the trims stay as guards.
- 5A file builder: compensated in _frame_body_bytes; that pairing is removed,
else a real 0x10 ending a chunk (one in ten do) would be dropped.
Stored .a5.pkl frames: A5_PICKLE_VERSION 2; load_a5 drops the stray 0x10
from version-1 frames. All 28 pickles on this box rebuild byte-identical
to dev's build.
Operational consequence: none for prod's stored events (S3 events arrive
through save_imported_bw, which keeps no frames); no schema change, no
TOOL_VERSION bump, no backfill.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
The trace decoder required all four records 0x3c-0x3f, so BE16352 (no
mic: 0x3c-0x3e only, all 8 of its DL2 events) got no sensor-check traces
at all. The three geophone records, chained by their length prefixes,
are now enough. The .h5 writer already stores a three-channel set.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The record chain that starts with the embedded event record runs to the
file's end on all 70,041 DL2 files: the event record 0x05, the unit's
summary 0x32-0x35, its sensor checks 0x3c-0x3f, then the footer 0x0e
(no 0x35 / 0x3f on a unit without a mic, 8 files). _record_chain walks
it and refuses a chain that does not end exactly at the file's end; the
unit's summary is now read from it too.
Each sensor-check record's header holds the results (DL2, 2026-11-06):
[2] channel type (1 geophone, 2 mic, 0 disabled), [4] status (0 =
passed), [5:7] frequency x 10, [7:9] ratio x 10, [9:11] amplitude mV.
Blastware prints them as they are: 209,943 / 209,943 geophone
frequencies and ratios, 69,975 / 69,975 mic frequencies and amplitudes;
"Passed" on status 0, "Check" on every other (its bits not decoded:
a Check can sit inside every passing range), "Disabled" on type 0.
Event.sensor_check_results: channel -> SensorCheckResult (result,
status, freq_hz, ratio, amplitude_mv). The checker compares them.
Behaviour change: an unknown id inside an intact chain now leaves only
that record unread (was: everything after it).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
After its embedded event record, every Blastware event file carries the
unit's own per-channel summary: a chain of [length][id][payload] records,
ids 0x32 Tran .. 0x35 MicL, each with min, max, peak sample,
half-period and a displacement integral; the event record itself holds
the vector-sum peak's sample. Blastware prints these as they are
(measured on DL2, 2026-11-05):
- ZC frequency = (rate / 2) / half-period: 15,844 / 15,844 waveform and
104,000 / 104,000 histogram values; every word too (">100" at <= 5
samples, "N/A" at 0, "<1.0" beyond rate / 2). Recomputing from the
samples had reached 46%: the unit works at full resolution.
- peak displacement = half the integral x 16 counts x in/s per count /
rate: 19,479 / 19,479 (84% recomputed).
- times of peak and the vector-sum time now come from the unit's peak
samples. They equal the samples' argmax on 25,962 / 25,966 channels;
the 4 others are O117I1NK.R70W, whose stored samples wrap at the
trigger (Blastware's own sample table has the same wrapped values).
The event-record readers return the validated record's offset, so the
summary is read from that spot only. No summary: nothing is set, and
times of peak stay the samples'.
The checker reports ZC frequency and displacement, and reads the mic's
above-range flag under its real name (mic_zc_above_range).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
From the 2026-11-04 bench:
- A MiniMate settings preview warns that a change is lost if someone is in
the unit's setup menu: a write sent with the menu open was acknowledged
and read back, then lost on Cancel or Save -- the menu writes its own
copy of the whole block back (measured both ways on BE9441).
- The two bytes after the MiniMate settings block went out as 00 00 and
the unit took them; the preview note says so instead of 'unmeasured'.
- A Micromate call-home plan no longer warns about 0x00 / 0x01: UM20147
took both, each way, on 11-03 and 11-04, matching its menu.
- read_waveform_data_raw drops the escaped-checksum's stray 0x10, as the
settings read does (it failed closed: the write's block check refused
203 bytes).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
S3_ALARM_WRITE_MEASURED = True. At the bench on BE9441, with Brian's go,
the alarm went 1.0 -> 1.5 -> 1.0 in/s: each write acknowledged, read back
as sent, and shown in the unit's own setup menu. The write moved exactly
channel +39 of the three geophone blocks (the f32 at +38), where the
event files put it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Every printed acceleration in DL2 bounds Blastware's g; together they
leave [386.2236, 386.2240] in/s^2, and 386.2238 fits 19,475 / 19,479
values. The other 4 are one odd file (O117I1NK.R70W, whose peak times
are also off) and one sample mismatch. That is 9.81 m/s^2 (386.2205,
19,423) plus an unexplained offset, as with the mic's fitted dB offset.
The 59 values 9.81 left were all one last digit high.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Group D, part 1, measured on 400 DL2 waveforms (2026-11-04):
- time of peak = (first peak sample - pre-trigger samples) / sample
rate, per channel including the mic: 1,197 / 1,197 geophone values
- the vector sum's time, the same on sqrt(T^2 + V^2 + L^2): 398 / 399
- peak acceleration = the largest |v[i+1] - v[i]| x sample rate / g,
with Blastware's g = 9.81 m/s^2: 1,190 / 1,197 (the standard 9.80665
gives 1,073). Blastware's manuals: 'subtracts two velocity readings
and divides the result by the elapsed time between them'.
PeakValues gains *_time_of_peak, pvs_time and *_peak_accel_g, filled
for waveforms only. The checker reports them. Displacement (84% with
the manuals' half-cycle integral) and ZC frequency (46%) are not shipped
yet -- Blastware does something more there.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Bench 2026-11-04, BE9441 live: frame B of a 1A read arrived one byte long,
ending in a lone 0x10. When a frame's checksum byte is itself escaped
(02 / 03 / 04, about one frame in 85) the parser keeps the escape's 0x10
and strips only the byte after it. The 12 recorded reads never hit it,
so the assembled block was 2,091 bytes and SFM refused it as 'monitoring'.
read_compliance_content now passes the lengths it asked for (1024, 1024,
42) and that one stray byte is dropped; any other leftover still fails
is_compliance_content. The trimmed read decodes exactly as the old
decoder read the same reply.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Since #51 a waveform and a histogram recorded in the same second are two
events (UNIQUE(serial, timestamp, record_type)). persist_download's
'already stored?' checks matched any row at the second and any row under
the letterless Blastware name both twins share, so a live download of
one twin was skipped as stored. Both checks now hold to the download's
own type, read from its file (STRT[18]; IDFW / IDFH); an untyped row at
that second, or a download whose type does not read, still counts as
stored. find_event_by_blastware_name takes an optional record_type.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Brings the checker's file-only decode work onto the parity branch so the
phase-5 bench runs on the code that will ship. One conflict, the CRLF
Series-III reference changelog: both kept, phase 5's row numbered
'2026-11-03 (5)' above dev's (4)/(3)/(2). test_event_ingest's live-
histogram dedup test asserted the stored row sits a second off the 0C
time -- the #51 bug, fixed on dev -- so its premise now reads the event's
own second; the dedup it tests still holds.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
From the whole-branch review of phase 5:
- The preview's revision now covers the changes asked for, so a live
change must be exactly what was previewed (any API caller, not only the
page). It covers what the preview showed -- the settings block (and a
Micromate's setup name) -- not the blocks a write only echoes, which are
re-read at send and sent as read (a MiniMate's trigger block byte 5
differs by session, #46).
- The units' limits hold on the block that would result: a range, rate or
mode change alone can no longer leave a held trigger, alarm or record
time over them.
- Every MiniMate block read is logical, so push_config_raw no longer
unescapes again (a job number of 4098, 10 02, was refused at Send); the
preview runs the write's own block check, so a block it would refuse is
shown as blocked.
- A MiniMate's monitoring refusal says a stop makes it call in (spec).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
The Config tab by serial is now the unit's edit form, headed 'On the
unit <serial> -- read HH:MM' and built from the server's editable
fields. Preview runs a dry run and shows old -> new, notes and anything
that blocks the change; Send (confirm) sends exactly what was previewed,
with its revision, then shows what the unit now holds and re-reads it.
An edit after a preview disables Send until the next preview. The
by-host form loses its write button; the read stays. Logic in
device_routing.js (Node-tested), glue in sfm_webapp.js, no inline JS.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
DeviceAccess.change_settings refuses before any I/O a request with no
changes, a live change without its preview's revision, or no audit log,
then dispatches the series' change (never retried). The route returns
the preview (fields old -> new, warnings, blocked, revision) or the
result (fields old/new/now), statuses as the other changes, and marks
the cached by-host config dirty after a live change.
/device/config and /device/config/project now answer 410 with a pointer.
Deleted with them: MiniMateClient.apply_config / set_project_info and
the raw-offset _encode_compliance_config (#46 found it wrong), the
lab script poc_set_project.py and experiments.py's EXP6, both of which
wrote a live unit through it. Git keeps them.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Series3Adapter.settings reads the 1A block assembled into its 2,090
logical bytes and decodes it with micromate.setup_fields (a monitoring
unit's device-info answer is refused with 'stop monitoring first').
change_settings runs the shared change core: read the four settings
blocks, patch the settings block's fields, send Blastware's sequence
through push_config_raw with the event index, trigger and waveform blocks
as read, re-read. Refused before sending: monitoring, a value the unit
does not allow, a stale preview. push_config_raw's pre-check now raises
ImageRefused, so a refused image is audited as nothing sent.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
s4_change_settings runs the shared change core with a read-back verdict
for its state (as asked / unchanged / differs). It reads the active
setup's name (unstripped), the preferences, trigger and setup blocks and
the schedule; patches the setup through micromate.setup_fields; sends
THOR's setup push (0xDA 68 73 82 83 71 72, now enableable) once; reads
the setup back. Refused before sending: a monitoring unit, a value the
unit does not allow (422), a stale preview (SettingsChanged, 409), and --
shown as 'blocked' in the preview -- the factory setup, a schedule that
loads another setup, an unreadable schedule, or a block SFM has not seen
(ChangeRefused, 409). s4_settings carries the editable fields.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
MicromateProtocol.read_file: 0x94 + path, then 0x48 pages to an
all-zero reply -- THOR's frames byte for byte (UM12947, 2026-09-24),
including params[3] = 1 on 0x94 and params[7] = 1 on the first 0x48.
micromate.schedule parses the 260-byte records (two- and five-entry
schedules from THOR's captures) and names the scheduled starts that
would load a setup other than the active one, ignoring case. The
client gains the raw (unstripped) active-setup name and the prefs /
trigger / setup content reads a setup push sends back.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
With the start right, the rest of Blastware's histogram timing follows,
measured on a 2,000-histogram DL2 sample:
- each interval's printed time is its end, start + (i + 1) x interval,
capped at the stop: 2,308,524 / 2,308,524 rows
(event_file_io.interval_times)
- each of Tran / Vert / Long / PVS / MicL's peak date and time is that of
the interval holding its first maximum: 2,000 / 2,000 each.
The checker compares intervals.Time and the ten peak date/time fields.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The footer's start runs a second early on 97% of histograms. Each
histogram carries an event record like a waveform's -- lead 00 28 05 00,
source 04 00, marker fe f5, then start and stop -- and it holds
Blastware's Histogram Start and Stop on 63,490 / 63,490 DL2 histograms.
On all 63,500 there is exactly one, its start 0 or 1 s after the
footer's and its stop 0 or 1 s before; that is the validation rule.
Without a validated record the footer's start stands, as a decode
problem.
Ships with the unit + time + type key (ea2dfc2), without which a
waveform and its histogram at the same second would collide. Three
tests that pinned the old footer start (one said 'for now', pointing at
#51) now pin the record's, which equals the file's Blastware name.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
micromate/setup_fields.py: the fields an operator can change (record
mode, sample rate, interval, record time, geophone trigger, Series 3's
range and -- read-only until benched -- alarm, job number and its report
flag, the four notes by slot), the units' own limits from Instantel's
manuals, field-only byte patching (bit fields bit by bit; Series 3's
[26:28] as Blastware writes it; Series 4's CRC recomputed), the
read-back verdict compared by bytes, and the preview revision.
All 11 Blastware compliance writes reproduce from the block before them
(BE11529's first also shows Blastware re-rendering two mic levels
through its dB value; SFM echoes the unit's bytes); Series 4 keypad
fixtures reproduce pairwise.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Under the unit + time + type key, the test's untyped neighbour no longer
shared the imported waveform's key, so the waveform was stored as its
own row -- the neighbour untouched, which is what the test's name asks.
The guard's job is an estimate landing on another waveform's second, so
the neighbour is now a waveform. A companion test pins the case the new
key allows: an estimate beside a histogram at its second is stored
alongside it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The events table was UNIQUE(serial, timestamp): one event per unit per
second. A unit records a waveform and a histogram in the same second
legitimately -- 209 times in prod's 2026-09-30 store once histograms
carry Blastware's start -- so the key is now (serial, timestamp,
record_type). Agreed with Brian 2026-11-03.
- Migration 3 rebuilds the table from its own current definition with
only the key swapped, in one transaction: every column, row and id is
kept (Terra-View reads rows by id) and the indexes are recreated.
Migration 1's check no longer mistakes the new key for a missing one.
- The upsert, the estimate guard and the restamp match on the type too.
The restamp also re-types a file's own row in place: before v0.33.0 a
row's type came from the filename, and a re-import under the file's
own type must not add a second row.
- An untyped event still refreshes the untyped row at its second (a
UNIQUE key treats NULLs as distinct).
- scripts/repair_unknown_serials.py checks the new key.
No time changes yet: that is the next commit, and they ship together.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Unescape each 1A data frame, take data[11:], drop the one non-content
byte that starts every frame but the last: 2,090 bytes headed by
N = 2090, Series IV's 0x1A layout. Measured on BE9441's 10-26
recording (12 reads, both frame patterns); the read after each
Blastware write equals the image written. read_compliance_content is
strict (a missing frame raises) and unjudged (a monitoring unit's
device-info answer comes back for the caller to recognise).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Blastware prints OORANGE for an interval's vector sum when it exceeds
the range in an interval where Blastware also clamped a channel: 17 / 17
DL2 cells, SFM's sum 10.01 .. 17.33 in/s (sqrt 3 x 10.005). The
saturation carve-out now covers intervals.Geo PVS in/s with that rule,
per interval, as it already did for PeakVectorSum. The 4 other cells
left mismatching sit 4e-6 past a rounding boundary (Blastware's
arithmetic is a hair lower) and stay mismatches.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Group B of the file-only decode, measured on DL2 2026-11-03:
- Frequency = (sample rate / 2) / half-period: 527,915 / 527,915 cells
at 1024 sps and 1,725 / 1,725 at 2048. #50: half_period_to_hz took a
fixed 512 and halved every 2048-sps frequency; it now takes the rate
(default 1024). Blastware prints 'N/A' for a half-period of 0, '>100'
('>200' at 2048) at 5 samples or fewer, '<1.0' below 1 Hz.
- Each interval's vector sum, sqrt(PVS^2) at the event's range:
771,354 / 771,354.
- Interval size: uint16 seconds at k - 40 (Series IV [8:10]).
- Stop: the footer's (2,995 / 2,999 sampled; 4 print a second earlier).
Event gains histogram_interval_sec, interval_half_periods, interval_pvs
and stop_time; the .h5 gains /intervals/half_period/<ch>,
/intervals/pvs_ips and a histogram_interval_sec attr. The decoder walks
a histogram once (histogram_codec.channels_from_records) and takes the
event's PVS from the same records. The checker compares each interval
column, number or Blastware's word; the test that pinned Tran Freq Hz
as blank now pins the match.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Brings be5bab4 and its history from the decode checker's branch: a Blastware
file's job number; decode_blastware_bytes choosing the codec by STRT[18] and the
histogram layout check by peak <= PVS <= sqrt(3) peak; the footer as the file's
last 26 bytes (no day-late histograms); docs (reference Appendix D.6, the
file-only status).
Conflicts, both kept whole:
- CLAUDE.md: this branch's 'Narrowed 2026-10-26' 5A block stays, followed by
dev's 'Open, not blocking' line (the 8x sensitive-range item struck out --
resolved by the file's range).
- docs/instantel_protocol_reference.md (CRLF, byte-safe): the change-log rows in
date order -- dev's 2026-11-03 and 2026-11-02, this branch's 2026-11-03
(call home), 2026-10-29 and 2026-10-27 (#46, this branch only).
Suite on the merged tree: 1399 passed, the 16 known failures.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Measured at the bench 2026-11-03 (UM20147): monitoring, a Micromate returns its
real call-home block and ACKS a call-home write, but does not apply it -- three
read-backs unchanged, and its own menu says 'Feature disabled while monitoring'.
SFM now refuses up front (UnitStateUnknown, 409: '... is monitoring -- a Micromate
ignores call-home changes while monitoring ...; stop monitoring first -- nothing
sent'), dry run included, instead of sending a write the unit ignores.
And the block must be the call-home block: micromate.writes.is_call_home_content
checks its header is its own length (00 7C, N = 124 -- 00 7C DC on every read,
UM12947 and UM20147). plan_call_home_enabled refuses any other 126 bytes, the
change refuses before sending, and call_home_state says why (enabled = None).
At the bench this was checked by eye before the monitoring write.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Measured at the bench 2026-11-03 (BE9441): while monitoring, a MiniMate answers
the 0x2C call-home read with its DEVICE-INFO block ('Instantel', 'MiniMate Plus',
its serial) -- as it answers 1A -- and idle again, minutes later, the call-home
block. SFM writes back only a block it just read, so a monitoring MiniMate's
call-home cannot be changed; the change core already refused (byte 5 read as
'unknown(0x6E)', nothing sent), but said so cryptically.
- minimateplus.protocol.is_call_home_block(raw): the block starts with its own
length 0x7C and is N (or N + 2) bytes unescaped; the device-info block fails it.
- The Series-3 change raises UnitStateUnknown (409) with 'did not return its
call-home settings -- a MiniMate answers the call-home read with its
device-info block while monitoring; stop monitoring first ... nothing sent',
for a dry run too. call_home_state returns enabled = None with that reason.
- The page's callHomeRows shows the reason in place of 'Unknown (byte 5 = ...)'.
A blind write while monitoring stays untested on purpose.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
K441LA17.IN0W's report says Units 'in/s and psi(L)' yet prints
MicTriggerLevel '125.0 dB(L)'. The value states its own unit, so that
is the one compared; the report's Units is the fallback. It was the
only MicTriggerLevel mismatch in DL2 (SFM's 0.005158 psi is 125.0 dB).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9