Commit Graph
265 Commits
Author SHA1 Message Date
serversdownandClaude Opus 5.5 ff705ebf87 merge: an escaped checksum is the checksum, not data (#58)
S3FrameParser kept the 10 of a checksum sent as `10 02/03/04` as the reply's
last data byte.  It now takes the pair: 7,747 / 7,747 recorded replies check,
272 of them with an escaped checksum.  Fixes the 1C battery/memory misread
(419.84 V on 12 of 760 recorded status replies) and the 2C call-home read; the
5A file builder's own compensation is removed with it, and pre-fix .a5.pkl
frames are converted on load (A5_PICKLE_VERSION 2).  checksum_valid now sums
the unescaped payload.

Conflict: the reference's changelog table (dev's own 2026-11-06 row); #58's
row kept as 2026-11-06 (2).  Suite on the merge: 1,693 passed, 0 failed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-12 15:27:00 -05:00
serversdownandClaude Opus 5.5 8c6cad681c test: the suite runs green -- fix the 16 long-standing 'known failures'
They were two stale tests, not broken code:
- tests/test_bw_ascii_report.py (15) read its Blastware ASCII reports
  from decode-re/5-8-26/ at the repo root, removed when the fixtures
  moved to tests/fixtures/decode-re-5-8-26/.  At the real path all 27 of
  its tests pass.  The same stale path made a report-pairing test in
  test_event_file_io.py skip silently; it now runs and passes.
- test_save_imported_bw_without_report_works_unchanged (1) expected a
  sample-less event's PPV to be 0.0.  Since fa9d3cd (2026-05-20) the
  decoder deliberately leaves peaks unknown (None) so a backfill never
  writes zeros over real peaks; the sidecar-level check now says so.
  Its main assertion -- no bw_report block without a report -- is
  unchanged and covered nowhere else.

Full suite: 1,620 passed, 0 failed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-11 14:54:16 -05:00
serversdownandClaude Opus 5.5 6818e3023e feat(checker): a histogram row printing one unit in both mic columns is the mixed-units case
The ~20 histograms with one mic interval off were Blastware printing
the same number in both mic columns of a row: I145HKWT.DY0H row 672
reads 95.92 under psi(L) and dB(L) (count 5: dB), S353K894.OE0H rows
106 and 608 read 0.000 under both (count 2: psi).  SFM's count agrees
with the neighbouring rows and with the other column.  mic-units-mixed
now covers the interval mic columns too; a column names its own unit.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-09 14:45:41 -05:00
serversdownandClaude Opus 5.5 0b6150adb5 feat(checker): read each mic value in the unit Blastware printed; carve out mixed columns
Blastware's dB(L) / psi(L) labels do not hold for the mic on every
report (DL2, 2026-11-09):
- the mic peak carries its own <Units>, which 7 reports set to dB under
  a psi Units line and 3 the reverse: the checker now reads the peak in
  its own unit;
- a mic sample table has no unit of its own and need not follow the
  line (S353JTHU.DT0W prints dB under psi): the checker reads it from
  its cells -- a mic dB value is never under 60, psi never over 1;
- some reports mix the two inside one column: K441L9IN.OT0W prints psi
  '0.000' for counts of 1 to 3 in a dB table.  Carve-out
  mic-units-mixed accepts a mic field when every cell SFM disagrees
  with is SFM's own value in the other unit: 19 DL2 events (14 sample
  tables, 5 peaks); a cell matching neither stays a mismatch.

Not a decoder change: SFM's mic data were right.  Checker run
20261109-141808: 78 of 88 fields, 0 regressions; no mic peak or mic
sample table mismatches left.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-09 14:44:11 -05:00
serversdownandClaude Opus 5.5 e21d23a3f2 fix(decode): the mic dB offset is 81.938216, fitted on every count Blastware printed
The 81.9384 offset came from a window fitted on histogram intervals,
[81.9383, 81.9385], which was too high.  Every count Blastware printed
in DL2 -- 1,704 in waveform sample tables, 520 in histogram intervals,
494 histogram peaks -- leaves [81.9382058, 81.9382266]: count 129
(124.2) bounds it from below, 463 (135.2; 81.9384 prints 135.3) and 677
(138.5) from above.  One offset serves all three printing paths; no
count prints two ways once range-1 mics and psi-formatted tables are
set aside.  Fixes the mic samples and peaks that sat one digit off at a
rounding edge.  The old window's comment is kept, retracted in place.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-09 14:04:55 -05:00
serversdownandClaude Opus 5.5 e25784d9db feat(decode): over range inside a histogram's intervals, as in the event
Inside an interval the rule is the event's: a peak past 2,000 units
(the mic in counts) is Blastware's OORANGE, and the interval's vector
sum is OORANGE when any geophone is.  DL2 (2026-11-09): numeric up to
1,846 (geophones) / 1,414 (mic), OORANGE from 2,001; vector sums 16 / 16
OORANGE with a geophone over, 2,862 / 2,862 numeric without.

event_file_io.over_full_scale(count, channel); the checker renders those
interval cells as OORANGE.  The saturation carve-out compares SFM's own
words properly (_differs): an OORANGE from SFM never counts as
saturation, and an OORANGE equal to Blastware's is not a difference.
Its interval tests run on the numeric values it used to see.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-09 13:35:08 -05:00
serversdownandClaude Opus 5.5 836c9e864b fix(decode): the mic's own range -- a range-1 mic reads an eighth
The mic's channel block carries a range byte at the geophones' offset
(label + 29, reference D.6.4).  At 1 each count is an eighth, 0.25 / 8
Pa: set on 7 DL2 events, all of them Blastware's values divided by 8,
and on none of the other 70,026 -- independently of the geophone range
(28 events have Sensitive geophones and a range-0 mic).  SFM read those
7 mics 8x high: K557J1XQ.GF0W is 79.4 dB(L), not 97.5.

Event.mic_range; the decoded mic peak (and so the .h5 mic samples, whose
scale is the peak's) and the checker's mic conversions follow it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-09 13:32:07 -05:00
serversdownandClaude Opus 5.5 af8dde5114 feat(decode): over range from the unit's own peaks -- Blastware's OORANGE
A channel is over range when the unit's own peak (its summary's min /
max) passes 2,000: 32,000 counts, full scale, on either geophone range;
the mic in counts.  Blastware prints OORANGE for that channel's peak,
for the vector sum when any geophone is over, and its "Out of Range"
line when the mic is (DL2, 2026-11-09): numeric up to 1,991 / 1,933,
OORANGE from 2,001; the vector sum is OORANGE on all 43 events with a
geophone over and on none of the 38 whose vector sum alone passes
10 in/s -- the open "vector sum alone" carve-out was never needed.

PeakValues gains tran/vert/long/mic/pvs_over_range.  The checker matches
OORANGE by the flag, and calls a flag against a printed number a
mismatch.  Clipped events that the saturation carve-out used to accept
now match outright; the carve-out stays as the fallback for a file
without the unit's summary, and its guards are tested that way.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-09 12:51:57 -05:00
serversdownandClaude Opus 5.5 b6309027b3 feat(decode): the monitor log line from the file's footer (group F)
Blastware prints one Monitor Log line per event: the footer's start and
stop, then words for the footer's flag word [18:20] -- 69,983 / 69,983
DL2 lines, character for character (2026-11-08):

  0x0001 Event Recorded       0x0010 Timer Stop
  0x0002 Keyboard Exit        0x0020 Modem Exit
  0x0004 Remote Exit          0x0200 Battery Low Exit
  0x0008 Selfcheck Passed     0x0800 Memory Full Exit

One line sets Modem and Timer and prints Modem, so the higher bit wins
(the order of the others is inferred).  Footer [20:22] is the event
record's trigger source again (69,983 / 69,983); [22:24] is zero; [24:26]
is not a common CRC-16 or sum.

Event.monitor_log: MonitorLogLine(start, stop, flags, description), read
only when the file's record chain is whole, which proves the footer.
The checker compares it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-08 03:43:05 -05:00
serversdownandClaude Opus 5.5 47da0ddef0 fix(framing): checksum_valid sums the reply's payload unescaped
S3FrameParser summed its payload with the kept `10` of each `10 02/03/04`
still in, so checksum_valid was False on about a third of good replies (the
old "S3 checksums frequently fail" belief).  SUM8 of the unescaped payload
is the unit's checksum on 7,747 of 7,747 recorded replies; the test pins it
on the 2,509 in the committed October fixtures (62 with an escaped checksum),
which also proves #58's split of data from checksum on real replies.

Nothing decides on checksum_valid; seismo_lab's display stops crying wolf.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-06 14:54:45 -05:00
serversdownandClaude Opus 5.5 89c5234ac0 fix(framing): an escaped checksum no longer leaves its 0x10 in a reply's data (#58)
A MiniMate sends a checksum of 02, 03 or 04 as `10 X`.  S3FrameParser kept
both bytes and _finalise took only the last as the checksum, so the frame's
data ended in a stray 0x10.  It now takes the pair.

Measured on every recorded reply (60 captures, March to October 2026): SUM8
of the unescaped payload is the checksum on 7,747 of 7,747; 272 arrived
escaped, all valid as an escape pair.

What the stray byte did:
- 1C status: battery and memory are counted from the end; 12 of 760 recorded
  status replies read 419.84 V / 251,654,656 bytes (6.76 V / 983,026).
- 2C call-home read: one byte long, refused as "monitoring".
- 1A, 09 reads: already trimmed (bench 2026-11-04); the trims stay as guards.
- 5A file builder: compensated in _frame_body_bytes; that pairing is removed,
  else a real 0x10 ending a chunk (one in ten do) would be dropped.

Stored .a5.pkl frames: A5_PICKLE_VERSION 2; load_a5 drops the stray 0x10
from version-1 frames.  All 28 pickles on this box rebuild byte-identical
to dev's build.

Operational consequence: none for prod's stored events (S3 events arrive
through save_imported_bw, which keeps no frames); no schema change, no
TOOL_VERSION bump, no backfill.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-06 14:52:50 -05:00
serversdownandClaude Opus 5.5 f222ea9e80 fix(sensor-check): a unit without a mic keeps its three geophone traces
The trace decoder required all four records 0x3c-0x3f, so BE16352 (no
mic: 0x3c-0x3e only, all 8 of its DL2 events) got no sensor-check traces
at all.  The three geophone records, chained by their length prefixes,
are now enough.  The .h5 writer already stores a three-channel set.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-06 13:00:16 -05:00
serversdownandClaude Opus 5.5 f7b310b130 feat(decode): sensor check results from the unit's own records (group E)
The record chain that starts with the embedded event record runs to the
file's end on all 70,041 DL2 files: the event record 0x05, the unit's
summary 0x32-0x35, its sensor checks 0x3c-0x3f, then the footer 0x0e
(no 0x35 / 0x3f on a unit without a mic, 8 files).  _record_chain walks
it and refuses a chain that does not end exactly at the file's end; the
unit's summary is now read from it too.

Each sensor-check record's header holds the results (DL2, 2026-11-06):
[2] channel type (1 geophone, 2 mic, 0 disabled), [4] status (0 =
passed), [5:7] frequency x 10, [7:9] ratio x 10, [9:11] amplitude mV.
Blastware prints them as they are: 209,943 / 209,943 geophone
frequencies and ratios, 69,975 / 69,975 mic frequencies and amplitudes;
"Passed" on status 0, "Check" on every other (its bits not decoded:
a Check can sit inside every passing range), "Disabled" on type 0.

Event.sensor_check_results: channel -> SensorCheckResult (result,
status, freq_hz, ratio, amplitude_mv).  The checker compares them.
Behaviour change: an unknown id inside an intact chain now leaves only
that record unread (was: everything after it).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-06 12:58:31 -05:00
serversdownandClaude Opus 5.5 9091fe75a9 feat(decode): ZC frequency, peak displacement and times of peak from the unit's own event summary
After its embedded event record, every Blastware event file carries the
unit's own per-channel summary: a chain of [length][id][payload] records,
ids 0x32 Tran .. 0x35 MicL, each with min, max, peak sample,
half-period and a displacement integral; the event record itself holds
the vector-sum peak's sample.  Blastware prints these as they are
(measured on DL2, 2026-11-05):

- ZC frequency = (rate / 2) / half-period: 15,844 / 15,844 waveform and
  104,000 / 104,000 histogram values; every word too (">100" at <= 5
  samples, "N/A" at 0, "<1.0" beyond rate / 2).  Recomputing from the
  samples had reached 46%: the unit works at full resolution.
- peak displacement = half the integral x 16 counts x in/s per count /
  rate: 19,479 / 19,479 (84% recomputed).
- times of peak and the vector-sum time now come from the unit's peak
  samples.  They equal the samples' argmax on 25,962 / 25,966 channels;
  the 4 others are O117I1NK.R70W, whose stored samples wrap at the
  trigger (Blastware's own sample table has the same wrapped values).

The event-record readers return the validated record's offset, so the
summary is read from that spot only.  No summary: nothing is set, and
times of peak stay the samples'.

The checker reports ZC frequency and displacement, and reads the mic's
above-range flag under its real name (mic_zc_above_range).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-05 14:00:13 -05:00
serversdownandClaude Opus 5.5 401d83dc2c merge: a waveform's time of peak, vector-sum time and peak acceleration (group D, part 1)
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-04 17:54:56 -05:00
serversdownandClaude Opus 5.5 c790e20116 fix: bench follow-ups -- the setup-menu warning, observed call-home values, waveform read
From the 2026-11-04 bench:
- A MiniMate settings preview warns that a change is lost if someone is in
  the unit's setup menu: a write sent with the menu open was acknowledged
  and read back, then lost on Cancel or Save -- the menu writes its own
  copy of the whole block back (measured both ways on BE9441).
- The two bytes after the MiniMate settings block went out as 00 00 and
  the unit took them; the preview note says so instead of 'unmeasured'.
- A Micromate call-home plan no longer warns about 0x00 / 0x01: UM20147
  took both, each way, on 11-03 and 11-04, matching its menu.
- read_waveform_data_raw drops the escaped-checksum's stray 0x10, as the
  settings read does (it failed closed: the write's block check refused
  203 bytes).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-04 16:15:28 -05:00
serversdownandClaude Opus 5.5 55c7b7b5ae feat(codec): the MiniMate alarm level is writable (benched 2026-11-04)
S3_ALARM_WRITE_MEASURED = True.  At the bench on BE9441, with Brian's go,
the alarm went 1.0 -> 1.5 -> 1.0 in/s: each write acknowledged, read back
as sent, and shown in the unit's own setup menu.  The write moved exactly
channel +39 of the three geophone blocks (the f32 at +38), where the
event files put it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-04 16:12:58 -05:00
serversdownandClaude Opus 5.5 09f34c2c85 fix(decode): Blastware's g for peak acceleration, fitted to every DL2 value
Every printed acceleration in DL2 bounds Blastware's g; together they
leave [386.2236, 386.2240] in/s^2, and 386.2238 fits 19,475 / 19,479
values.  The other 4 are one odd file (O117I1NK.R70W, whose peak times
are also off) and one sample mismatch.  That is 9.81 m/s^2 (386.2205,
19,423) plus an unexplained offset, as with the mic's fitted dB offset.
The 59 values 9.81 left were all one last digit high.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-04 15:47:13 -05:00
serversdownandClaude Opus 5.5 233289d029 feat(decode): a waveform's time of peak, vector-sum time and peak acceleration
Group D, part 1, measured on 400 DL2 waveforms (2026-11-04):
- time of peak = (first peak sample - pre-trigger samples) / sample
  rate, per channel including the mic: 1,197 / 1,197 geophone values
- the vector sum's time, the same on sqrt(T^2 + V^2 + L^2): 398 / 399
- peak acceleration = the largest |v[i+1] - v[i]| x sample rate / g,
  with Blastware's g = 9.81 m/s^2: 1,190 / 1,197 (the standard 9.80665
  gives 1,073).  Blastware's manuals: 'subtracts two velocity readings
  and divides the result by the elapsed time between them'.

PeakValues gains *_time_of_peak, pvs_time and *_peak_accel_g, filled
for waveforms only.  The checker reports them.  Displacement (84% with
the manuals' half-cycle integral) and ZC frequency (46%) are not shipped
yet -- Blastware does something more there.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-04 15:19:53 -05:00
serversdownandClaude Opus 5.5 9992b25fde fix(s3): a settings read takes exactly what each frame was asked for
Bench 2026-11-04, BE9441 live: frame B of a 1A read arrived one byte long,
ending in a lone 0x10.  When a frame's checksum byte is itself escaped
(02 / 03 / 04, about one frame in 85) the parser keeps the escape's 0x10
and strips only the byte after it.  The 12 recorded reads never hit it,
so the assembled block was 2,091 bytes and SFM refused it as 'monitoring'.
read_compliance_content now passes the lengths it asked for (1024, 1024,
42) and that one stray byte is dropped; any other leftover still fails
is_compliance_content.  The trimmed read decodes exactly as the old
decoder read the same reply.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-04 13:11:32 -05:00
serversdownandClaude Opus 5.5 2d237be5ef fix(ingest): a live download is held to its record type (#51)
Since #51 a waveform and a histogram recorded in the same second are two
events (UNIQUE(serial, timestamp, record_type)).  persist_download's
'already stored?' checks matched any row at the second and any row under
the letterless Blastware name both twins share, so a live download of
one twin was skipped as stored.  Both checks now hold to the download's
own type, read from its file (STRT[18]; IDFW / IDFH); an untyped row at
that second, or a download whose type does not read, still counts as
stored.  find_event_by_blastware_name takes an optional record_type.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-04 12:34:46 -05:00
serversdownandClaude Opus 5.5 f24913189b merge: dev 9b458b5 into the parity branch (group A/B, #51 histogram timing)
Brings the checker's file-only decode work onto the parity branch so the
phase-5 bench runs on the code that will ship.  One conflict, the CRLF
Series-III reference changelog: both kept, phase 5's row numbered
'2026-11-03 (5)' above dev's (4)/(3)/(2).  test_event_ingest's live-
histogram dedup test asserted the stored row sits a second off the 0C
time -- the #51 bug, fixed on dev -- so its premise now reads the event's
own second; the dedup it tests still holds.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-04 12:31:21 -05:00
serversdownandClaude Opus 5.5 08d0a6c0d4 fix(settings): final-review fixes -- revision, resulting limits, logical writes
From the whole-branch review of phase 5:
- The preview's revision now covers the changes asked for, so a live
  change must be exactly what was previewed (any API caller, not only the
  page).  It covers what the preview showed -- the settings block (and a
  Micromate's setup name) -- not the blocks a write only echoes, which are
  re-read at send and sent as read (a MiniMate's trigger block byte 5
  differs by session, #46).
- The units' limits hold on the block that would result: a range, rate or
  mode change alone can no longer leave a held trigger, alarm or record
  time over them.
- Every MiniMate block read is logical, so push_config_raw no longer
  unescapes again (a job number of 4098, 10 02, was refused at Send); the
  preview runs the write's own block check, so a block it would refuse is
  shown as blocked.
- A MiniMate's monitoring refusal says a stop makes it call in (spec).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 22:10:49 -05:00
serversdownandClaude Opus 5.5 385716d8e1 feat(webapp): edit a unit's settings by serial: preview, send, read back
The Config tab by serial is now the unit's edit form, headed 'On the
unit <serial> -- read HH:MM' and built from the server's editable
fields.  Preview runs a dry run and shows old -> new, notes and anything
that blocks the change; Send (confirm) sends exactly what was previewed,
with its revision, then shows what the unit now holds and re-reads it.
An edit after a preview disables Send until the next preview.  The
by-host form loses its write button; the read stays.  Logic in
device_routing.js (Node-tested), glue in sfm_webapp.js, no inline JS.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:57:17 -05:00
serversdownandClaude Opus 5.5 e8eabee4a2 feat(sfm): POST /device/settings/change; retire the legacy config write
DeviceAccess.change_settings refuses before any I/O a request with no
changes, a live change without its preview's revision, or no audit log,
then dispatches the series' change (never retried).  The route returns
the preview (fields old -> new, warnings, blocked, revision) or the
result (fields old/new/now), statuses as the other changes, and marks
the cached by-host config dirty after a live change.

/device/config and /device/config/project now answer 410 with a pointer.
Deleted with them: MiniMateClient.apply_config / set_project_info and
the raw-offset _encode_compliance_config (#46 found it wrong), the
lab script poc_set_project.py and experiments.py's EXP6, both of which
wrote a live unit through it.  Git keeps them.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:51:20 -05:00
serversdownandClaude Opus 5.5 66bb29b9d4 feat(s3): change a MiniMate's settings by serial on the shared codec
Series3Adapter.settings reads the 1A block assembled into its 2,090
logical bytes and decodes it with micromate.setup_fields (a monitoring
unit's device-info answer is refused with 'stop monitoring first').
change_settings runs the shared change core: read the four settings
blocks, patch the settings block's fields, send Blastware's sequence
through push_config_raw with the event index, trigger and waveform blocks
as read, re-read.  Refused before sending: monitoring, a value the unit
does not allow, a stale preview.  push_config_raw's pre-check now raises
ImageRefused, so a refused image is audited as nothing sent.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:46:50 -05:00
serversdownandClaude Opus 5.5 c082f72d62 feat(s4): change a Micromate's settings by serial, audited, schedule-checked
s4_change_settings runs the shared change core with a read-back verdict
for its state (as asked / unchanged / differs).  It reads the active
setup's name (unstripped), the preferences, trigger and setup blocks and
the schedule; patches the setup through micromate.setup_fields; sends
THOR's setup push (0xDA 68 73 82 83 71 72, now enableable) once; reads
the setup back.  Refused before sending: a monitoring unit, a value the
unit does not allow (422), a stale preview (SettingsChanged, 409), and --
shown as 'blocked' in the preview -- the factory setup, a schedule that
loads another setup, an unreadable schedule, or a block SFM has not seen
(ChangeRefused, 409).  s4_settings carries the editable fields.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:43:03 -05:00
serversdownandClaude Opus 5.5 d0335dbbbd feat(micromate): read the schedule file (read-only)
MicromateProtocol.read_file: 0x94 + path, then 0x48 pages to an
all-zero reply -- THOR's frames byte for byte (UM12947, 2026-09-24),
including params[3] = 1 on 0x94 and params[7] = 1 on the first 0x48.
micromate.schedule parses the 260-byte records (two- and five-entry
schedules from THOR's captures) and names the scheduled starts that
would load a setup other than the active one, ignoring case.  The
client gains the raw (unstripped) active-setup name and the prefs /
trigger / setup content reads a setup push sends back.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:37:30 -05:00
serversdownandClaude Opus 5.5 9cfa82117b feat(decode): histogram interval times and peak times (#51 group C)
With the start right, the rest of Blastware's histogram timing follows,
measured on a 2,000-histogram DL2 sample:
- each interval's printed time is its end, start + (i + 1) x interval,
  capped at the stop: 2,308,524 / 2,308,524 rows
  (event_file_io.interval_times)
- each of Tran / Vert / Long / PVS / MicL's peak date and time is that of
  the interval holding its first maximum: 2,000 / 2,000 each.
The checker compares intervals.Time and the ten peak date/time fields.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 21:35:54 -05:00
serversdownandClaude Opus 5.5 a9bb9f08c0 fix(decode): a histogram's start and stop come from its own event record (#51)
The footer's start runs a second early on 97% of histograms.  Each
histogram carries an event record like a waveform's -- lead 00 28 05 00,
source 04 00, marker fe f5, then start and stop -- and it holds
Blastware's Histogram Start and Stop on 63,490 / 63,490 DL2 histograms.
On all 63,500 there is exactly one, its start 0 or 1 s after the
footer's and its stop 0 or 1 s before; that is the validation rule.
Without a validated record the footer's start stands, as a decode
problem.

Ships with the unit + time + type key (ea2dfc2), without which a
waveform and its histogram at the same second would collide.  Three
tests that pinned the old footer start (one said 'for now', pointing at
#51) now pin the record's, which equals the file's Blastware name.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 21:33:32 -05:00
serversdownandClaude Opus 5.5 5ba72740dd feat(codec): one settings codec for both series, on the shared layout
micromate/setup_fields.py: the fields an operator can change (record
mode, sample rate, interval, record time, geophone trigger, Series 3's
range and -- read-only until benched -- alarm, job number and its report
flag, the four notes by slot), the units' own limits from Instantel's
manuals, field-only byte patching (bit fields bit by bit; Series 3's
[26:28] as Blastware writes it; Series 4's CRC recomputed), the
read-back verdict compared by bytes, and the preview revision.

All 11 Blastware compliance writes reproduce from the block before them
(BE11529's first also shows Blastware re-rendering two mic levels
through its dB value; SFM echoes the unit's bytes); Series 4 keypad
fixtures reproduce pairwise.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:33:01 -05:00
serversdownandClaude Opus 5.5 e24e77bfd0 test: the estimate guard's neighbour is an event of the same type (#51)
Under the unit + time + type key, the test's untyped neighbour no longer
shared the imported waveform's key, so the waveform was stored as its
own row -- the neighbour untouched, which is what the test's name asks.
The guard's job is an estimate landing on another waveform's second, so
the neighbour is now a waveform.  A companion test pins the case the new
key allows: an estimate beside a histogram at its second is stored
alongside it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 21:30:51 -05:00
serversdownandClaude Opus 5.5 ea2dfc21b7 feat(db): events are identified by unit + time + type (#51)
The events table was UNIQUE(serial, timestamp): one event per unit per
second.  A unit records a waveform and a histogram in the same second
legitimately -- 209 times in prod's 2026-09-30 store once histograms
carry Blastware's start -- so the key is now (serial, timestamp,
record_type).  Agreed with Brian 2026-11-03.

- Migration 3 rebuilds the table from its own current definition with
  only the key swapped, in one transaction: every column, row and id is
  kept (Terra-View reads rows by id) and the indexes are recreated.
  Migration 1's check no longer mistakes the new key for a missing one.
- The upsert, the estimate guard and the restamp match on the type too.
  The restamp also re-types a file's own row in place: before v0.33.0 a
  row's type came from the filename, and a re-import under the file's
  own type must not add a second row.
- An untyped event still refreshes the untyped row at its second (a
  UNIQUE key treats NULLs as distinct).
- scripts/repair_unknown_serials.py checks the new key.

No time changes yet: that is the next commit, and they ship together.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 21:29:46 -05:00
serversdownandClaude Opus 5.5 1bb15573fc feat(s3): assemble a settings read into the 2,090-byte block
Unescape each 1A data frame, take data[11:], drop the one non-content
byte that starts every frame but the last: 2,090 bytes headed by
N = 2090, Series IV's 0x1A layout.  Measured on BE9441's 10-26
recording (12 reads, both frame patterns); the read after each
Blastware write equals the image written.  read_compliance_content is
strict (a missing frame raises) and unjudged (a monitoring unit's
device-info answer comes back for the caller to recognise).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:28:04 -05:00
serversdownandClaude Opus 5.5 13f2769736 feat(decode_check): an OORANGE interval vector sum is saturation
Blastware prints OORANGE for an interval's vector sum when it exceeds
the range in an interval where Blastware also clamped a channel: 17 / 17
DL2 cells, SFM's sum 10.01 .. 17.33 in/s (sqrt 3 x 10.005).  The
saturation carve-out now covers intervals.Geo PVS in/s with that rule,
per interval, as it already did for PeakVectorSum.  The 4 other cells
left mismatching sit 4e-6 past a rounding boundary (Blastware's
arithmetic is a hair lower) and stay mismatches.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 18:02:51 -05:00
serversdownandClaude Opus 5.5 2b698e74cf feat(decode): a histogram's interval detail -- frequencies (#50), vector sums, interval size, stop
Group B of the file-only decode, measured on DL2 2026-11-03:

- Frequency = (sample rate / 2) / half-period: 527,915 / 527,915 cells
  at 1024 sps and 1,725 / 1,725 at 2048.  #50: half_period_to_hz took a
  fixed 512 and halved every 2048-sps frequency; it now takes the rate
  (default 1024).  Blastware prints 'N/A' for a half-period of 0, '>100'
  ('>200' at 2048) at 5 samples or fewer, '<1.0' below 1 Hz.
- Each interval's vector sum, sqrt(PVS^2) at the event's range:
  771,354 / 771,354.
- Interval size: uint16 seconds at k - 40 (Series IV [8:10]).
- Stop: the footer's (2,995 / 2,999 sampled; 4 print a second earlier).

Event gains histogram_interval_sec, interval_half_periods, interval_pvs
and stop_time; the .h5 gains /intervals/half_period/<ch>,
/intervals/pvs_ips and a histogram_interval_sec attr.  The decoder walks
a histogram once (histogram_codec.channels_from_records) and takes the
event's PVS from the same records.  The checker compares each interval
column, number or Blastware's word; the test that pinned Tran Freq Hz
as blank now pins the match.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 17:34:27 -05:00
serversdownandClaude Opus 5.5 cbce00f8e1 merge: dev into feat/series4-sfm-parity -- the decode checker's file-only fields (job number, codec by STRT[18], last-26-byte footer)
Brings be5bab4 and its history from the decode checker's branch: a Blastware
file's job number; decode_blastware_bytes choosing the codec by STRT[18] and the
histogram layout check by peak <= PVS <= sqrt(3) peak; the footer as the file's
last 26 bytes (no day-late histograms); docs (reference Appendix D.6, the
file-only status).

Conflicts, both kept whole:
- CLAUDE.md: this branch's 'Narrowed 2026-10-26' 5A block stays, followed by
  dev's 'Open, not blocking' line (the 8x sensitive-range item struck out --
  resolved by the file's range).
- docs/instantel_protocol_reference.md (CRLF, byte-safe): the change-log rows in
  date order -- dev's 2026-11-03 and 2026-11-02, this branch's 2026-11-03
  (call home), 2026-10-29 and 2026-10-27 (#46, this branch only).

Suite on the merged tree: 1399 passed, the 16 known failures.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 15:34:59 -05:00
serversdownandClaude Opus 5.5 f35845d403 fix(sfm): a Micromate's call-home is refused while monitoring, and only a real call-home block is ever edited
Measured at the bench 2026-11-03 (UM20147): monitoring, a Micromate returns its
real call-home block and ACKS a call-home write, but does not apply it -- three
read-backs unchanged, and its own menu says 'Feature disabled while monitoring'.
SFM now refuses up front (UnitStateUnknown, 409: '... is monitoring -- a Micromate
ignores call-home changes while monitoring ...; stop monitoring first -- nothing
sent'), dry run included, instead of sending a write the unit ignores.

And the block must be the call-home block: micromate.writes.is_call_home_content
checks its header is its own length (00 7C, N = 124 -- 00 7C DC on every read,
UM12947 and UM20147).  plan_call_home_enabled refuses any other 126 bytes, the
change refuses before sending, and call_home_state says why (enabled = None).
At the bench this was checked by eye before the monitoring write.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 15:32:02 -05:00
serversdownandClaude Opus 5.5 5326e99ac2 fix(sfm): a monitoring MiniMate's call-home says 'stop monitoring first', not 'unknown(0x6E)'
Measured at the bench 2026-11-03 (BE9441): while monitoring, a MiniMate answers
the 0x2C call-home read with its DEVICE-INFO block ('Instantel', 'MiniMate Plus',
its serial) -- as it answers 1A -- and idle again, minutes later, the call-home
block.  SFM writes back only a block it just read, so a monitoring MiniMate's
call-home cannot be changed; the change core already refused (byte 5 read as
'unknown(0x6E)', nothing sent), but said so cryptically.

- minimateplus.protocol.is_call_home_block(raw): the block starts with its own
  length 0x7C and is N (or N + 2) bytes unescaped; the device-info block fails it.
- The Series-3 change raises UnitStateUnknown (409) with 'did not return its
  call-home settings -- a MiniMate answers the call-home read with its
  device-info block while monitoring; stop monitoring first ... nothing sent',
  for a dry run too.  call_home_state returns enabled = None with that reason.
- The page's callHomeRows shows the reason in place of 'Unknown (byte 5 = ...)'.

A blind write while monitoring stays untested on purpose.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 14:19:19 -05:00
serversdownandClaude Opus 5.5 8d5a9987c9 fix(decode_check): compare a mic level in the unit it is printed in
K441LA17.IN0W's report says Units 'in/s and psi(L)' yet prints
MicTriggerLevel '125.0 dB(L)'.  The value states its own unit, so that
is the one compared; the report's Units is the fallback.  It was the
only MicTriggerLevel mismatch in DL2 (SFM's 0.005158 psi is 125.0 dB).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 14:02:27 -05:00
serversdownandClaude Opus 5.5 6c2eda5f63 feat(decode): a Blastware file's identity, battery and trigger settings
Group A of the file-only decode, every field matched against every DL2
report (2026-11-03):

- Identity block before the setup name, what the live read gets from
  SUB FE: serial k-202, firmware k-147, DSP version k-138, calibration
  date k-132 + 'by' k-128, manufacturer k-94, model k-72, firmware
  minor k-193.  Event.device_info (DeviceInfo gains calibration_date /
  calibrated_by).  Serial, Version and Calibration 69,983 / 69,983.
- Battery: uint16 hundredths of a volt at k-190 (Event.battery_volts).
  69,729 exact; the other 254 are Blastware rounding half up.
- Trigger source: the two bytes between the embedded event record's
  lead and fe 80, a bitmask (0x01 Tran 0x02 Vert 0x04 Long 0x08 MicL
  0x200 Manual): 6,493 / 6,493.  Event.triggered_by.
- Trigger settings in Series IV's 0x1A layout: sources bitmask k-19,
  stop mode k-31 (0 = Fixed), each channel's float32 level at
  label+30 (geo in/s, mic psi), mic type code at MicL+4 (2 = Linear
  Weighting).  Geo level 6,447 / 6,447, mic 4,403 / 4,403; Blastware
  prints a level when its channel is a trigger source and the event
  was not Manual.  The mic level's dB uses 6895 Pa/psi (4,272 / 4,272
  against 4,271 at 6894.757).
- .h5 attrs for all of them (additive).
- Checker: SFM's side reports the ten fields; the mic trigger level
  follows the report's dB/psi.  Carve-out
  units-is-a-display-preference: dB or psi is Blastware's PC setting
  when it wrote the report -- DL2's reports switch fleet-wide in 61
  clean runs by write time, and no byte of the file separates them.
  Two tests that pinned BatteryLevel / Calibration as blank now pin the
  match.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 13:38:39 -05:00
serversdownandClaude Opus 5.5 8a40eb638a fix(decode): a Blastware file's footer is its last 26 bytes -- no more day-late histograms
Every DL2 file ends in a valid footer: 0e 08 and two valid times on
70,041 / 70,041.  The decoder took the first '0e 08 + plausible year'
instead, and 14 files also hold an earlier record, ~1.1 KB before the
end, with the stop time followed by zeros:
- a histogram started at its own stop -- a day late on BE9558's daily
  histograms (K558L9XP.FK0H: 2025-10-08 19:10:01 for Blastware's
  2025-10-07 19:14:08); T003LCYV.JD0H got no time at all;
- a waveform lost its stop, so the trigger was never computed and the
  stop was stamped instead (K440I4LG.JK0W: 11:14:12 for 11:14:08).

The last 26 bytes are now taken when they are a footer; otherwise the
old search stands unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 12:10:44 -05:00
serversdownandClaude Opus 5.5 9e03b3f0ab fix(sfm): a Micromate in an unknown run state gets no call-home write, and a lost ack keeps its snapshot (phase-4 review)
- s4_change_call_home's read_state now returns an unknown(0xNN) run state as
  it is, so the change core refuses it (UnitStateUnknown, nothing sent), as
  start/stop already does; it checked only for calling_home.
- run_change records the snapshot on the lost-ack path too: after an ack is
  lost, what the unit now holds (and, on Series 4, whether [118:120] moved) is
  what tells whether the write landed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 17:23:59 -05:00
serversdownandClaude Opus 5.5 bdd76b8f74 fix(minimateplus): a built call-home image is framed once, never unescaped again (phase-4 review)
call_home_image returns the unescaped N + 2 image, but the send path handed it
to write_call_home_config, whose write_image unescapes again -- and unescaping
is not idempotent: a real 0x10 before 02/03/04 loses its 0x10.  A call-in time
of 16:02-16:04 (hour 0x10) is exactly that.  One such time made the send refuse
before the wire yet audited as 'sent, acknowledgement lost'; two made it send a
block shifted by two bytes from [101] (num_retries and the time fields wrong).
The Blastware-frame test could not see it: it checked the image builder, not
the bytes the protocol framed.

- MiniMateProtocol.write_call_home_image(image) frames a built image once
  (0x7E, ack 0x81, 0x7F, ack 0x80), raising ImageRefused before any byte when
  it is not a whole block; write_call_home_config (the legacy multi-field path)
  is write_image once + that.  Its stale 127-byte docstring is gone.
- MiniMateClient.write_call_home_image uses it.
- The Series-3 change passes is_refusal=ImageRefused, so a pre-wire refusal is
  audited as nothing sent (sent = 0), not as a lost ack.

Tests drive the real client -> protocol over a stub answering with BE11529's
recorded acks: the unit's own read, a 16:02 time, and 16:03 + 16:04 all go out
exactly as built; a short image is refused with nothing written.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 17:23:59 -05:00
serversdownandClaude Opus 5.5 51e7dddcb3 test(micromate): corpus counts are floors, and 0x71 is the over-the-ceiling example
Two test-side breaks, found by the full suite after phase-4 task 6:
- test_micromate_framing's three whole-session tests pinned exact counts of a
  gitignored corpus (bridges/captures/9-24-26 - micromate2, a symlink into the
  main checkout).  The full copy of the BW VM's captures on 2026-11-02 added
  sessions: 287 responses / 241 reads / 287 requests, every one passing the same
  per-frame checks.  The counts are now floors (>= 251 / 218 / 251), so a lost
  file still fails and a grown corpus does not.
- test_micromate_opcodes' beyond-the-ceiling permit took 0x7E, enableable since
  the call-home commit (eeb55ef); 0x71 (the setup write, phase 5) replaces it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 17:07:04 -05:00
serversdownandClaude Opus 5.5 84c142f36c feat(sfm): the page's Call Home tab by serial -- state and audited On / Off (phase 4)
device_routing.js (Node-tested): call_home_state / call_home_on / call_home_off
routes (serial required); controlsFor gains callHomeChange (by serial, a
confirmed Series 3 or 4) and callHomeRead now covers a Series 4 by serial;
serialPanes gains callHomeForm / callHomeBox; callHomeRows renders the switch
(On / Off / 'Unknown (byte 5 = 0xNN)'), dial string and series;
changeErrorText takes the whole label ('Start monitoring', 'Enable call-home').

sfm_webapp.js: by serial the Call Home tab hides the legacy multi-field form
(Series 3 by host only) and shows the unit's switch with On / Off.  Each asks
confirm(), sends one audited change, reports it with changeSummary /
changeErrorText, then re-reads quietly so the change's own result stays on
screen.  A different unit's switch is never left showing.  The new buttons are
wired with addEventListener, not onclick= (no inline JS).

Checked in jsdom against the real page: placeholder, read, Off (confirm, the
disable route, 'confirmed -- enabled -> disabled'), a serial edit clearing it,
legacy mode unchanged, no script errors.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 17:05:00 -05:00
serversdownandClaude Opus 5.5 06fa56db09 feat(sfm): call-home state and enable/disable by serial -- GET /device/call_home/state, POST /device/call_home/{enable,disable} (phase 4)
- DeviceAccess.call_home_state (a read) and set_call_home (change=True: never
  retried, audit required for a live change, dry run without one), routed by
  series like start/stop.  A config write is read back on its own window: up
  to 3 reads, 1 s apart, not the monitoring one.
- Routes, serial required (422 without), all three serial-aware: the state as
  a dict; enable / disable through _change_response, so their statuses are
  start/stop's and an unconfirmed change carries sent + audit_id.  The legacy
  GET / POST /device/call_home are unchanged (a Micromate serial is still
  refused there, 501).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 17:01:14 -05:00
serversdownandClaude Opus 5.5 453d42e32a test(s3): SFM's call-home write equals Blastware's, frame for frame -- opens the live send
Ground truth: Blastware changing BE11529's call-home settings on 2026-04-20
(Remote Access -> Setup Unit), paired raw files of what it sent and what the
unit answered: the read, the enable (read 0x00 -> wrote 0x01), the disable
(read 0x01 -> wrote 0x00).  From the unit's own read before each write, SFM's
0x7E frame (call_home_image + build_bw_write_frame) is Blastware's byte for
byte -- nothing but byte 5 differs from the read -- and the 0x7F confirm too.
Mutation-checked: inverting the byte SFM writes fails the test.

S3_CALL_HOME_FRAME_VERIFIED is now True; the gate stays tested shut by
monkeypatch, and a test pins that its comment names this proof.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 16:59:15 -05:00
serversdownandClaude Opus 5.5 8612cd9df7 feat(sfm): Series-3 call-home state and audited enable/disable, live send gated until its frame is verified (phase 4)
- minimateplus.protocol: call_home_enabled(raw) reads byte 5 of the UNESCAPED
  0x2C payload (0x01 on / 0x00 off, measured 2026-04-20; anything else None --
  bench finding #1's lesson: an escaped byte before it would move the raw
  index); call_home_image(raw, enabled) is write_image's N + 2 image with byte 5
  set and everything else as read, refusing a byte 5 never measured.
- MiniMateClient.read_call_home_raw() / write_call_home_image(image) (0x7E then
  0x7F, each ack checked, never retried).
- Series3Adapter.call_home_state (wake, then 0x2C; no serial read, like status)
  and change_call_home: the shared change core with a connect() identity check,
  state 'enabled' / 'disabled' / 'unknown(0xNN)' (unknown sends nothing), the
  plan showing both exact frames, a snapshot of both unescaped images.
- S3_CALL_HOME_FRAME_VERIFIED = False: a live change is refused (501) before any
  connection until the frame is reproduced from Blastware's (next commit).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 16:57:55 -05:00
serversdownandClaude Opus 5.5 eeb55effe9 feat(sfm): Series-4 call-home state and audited enable/disable (phase 4)
- micromate: ENABLEABLE_WRITES gains 0x7E/0x7F (the call-home write and its
  confirm; spec row 9, enable/disable only); MicromateClient.get_call_home_content()
  returns the 126-byte 0x2C content.
- sfm/device_access: CallHomeState (serial, series, enabled, dial_string, detail
  with byte5 and the whole block); s4_call_home_state reads bit 0 of [5] and the
  dial string at [6:46]; s4_change_call_home runs the shared change core with
  micromate.writes.plan_call_home_enabled -- built from the read run_change made
  just before, and that same plan is the one sent.  A unit calling home (run
  state 0x03) is refused, nothing sent.  The read-back judges the edited bit
  only; the snapshot records both blocks and every changed offset -- [118:120]
  is unit-maintained and always moves.
- The write-ceiling tests take 0x71 (the setup write, phase 5) as their
  over-the-ceiling example now that 0x7E is enableable.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 16:56:04 -05:00