Commit Graph
905 Commits
Author SHA1 Message Date
serversdownandClaude Opus 5.5 d0335dbbbd feat(micromate): read the schedule file (read-only)
MicromateProtocol.read_file: 0x94 + path, then 0x48 pages to an
all-zero reply -- THOR's frames byte for byte (UM12947, 2026-09-24),
including params[3] = 1 on 0x94 and params[7] = 1 on the first 0x48.
micromate.schedule parses the 260-byte records (two- and five-entry
schedules from THOR's captures) and names the scheduled starts that
would load a setup other than the active one, ignoring case.  The
client gains the raw (unstripped) active-setup name and the prefs /
trigger / setup content reads a setup push sends back.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:37:30 -05:00
serversdownandClaude Opus 5.5 9cfa82117b feat(decode): histogram interval times and peak times (#51 group C)
With the start right, the rest of Blastware's histogram timing follows,
measured on a 2,000-histogram DL2 sample:
- each interval's printed time is its end, start + (i + 1) x interval,
  capped at the stop: 2,308,524 / 2,308,524 rows
  (event_file_io.interval_times)
- each of Tran / Vert / Long / PVS / MicL's peak date and time is that of
  the interval holding its first maximum: 2,000 / 2,000 each.
The checker compares intervals.Time and the ten peak date/time fields.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 21:35:54 -05:00
serversdownandClaude Opus 5.5 a9bb9f08c0 fix(decode): a histogram's start and stop come from its own event record (#51)
The footer's start runs a second early on 97% of histograms.  Each
histogram carries an event record like a waveform's -- lead 00 28 05 00,
source 04 00, marker fe f5, then start and stop -- and it holds
Blastware's Histogram Start and Stop on 63,490 / 63,490 DL2 histograms.
On all 63,500 there is exactly one, its start 0 or 1 s after the
footer's and its stop 0 or 1 s before; that is the validation rule.
Without a validated record the footer's start stands, as a decode
problem.

Ships with the unit + time + type key (ea2dfc2), without which a
waveform and its histogram at the same second would collide.  Three
tests that pinned the old footer start (one said 'for now', pointing at
#51) now pin the record's, which equals the file's Blastware name.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 21:33:32 -05:00
serversdownandClaude Opus 5.5 5ba72740dd feat(codec): one settings codec for both series, on the shared layout
micromate/setup_fields.py: the fields an operator can change (record
mode, sample rate, interval, record time, geophone trigger, Series 3's
range and -- read-only until benched -- alarm, job number and its report
flag, the four notes by slot), the units' own limits from Instantel's
manuals, field-only byte patching (bit fields bit by bit; Series 3's
[26:28] as Blastware writes it; Series 4's CRC recomputed), the
read-back verdict compared by bytes, and the preview revision.

All 11 Blastware compliance writes reproduce from the block before them
(BE11529's first also shows Blastware re-rendering two mic levels
through its dB value; SFM echoes the unit's bytes); Series 4 keypad
fixtures reproduce pairwise.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:33:01 -05:00
serversdownandClaude Opus 5.5 e24e77bfd0 test: the estimate guard's neighbour is an event of the same type (#51)
Under the unit + time + type key, the test's untyped neighbour no longer
shared the imported waveform's key, so the waveform was stored as its
own row -- the neighbour untouched, which is what the test's name asks.
The guard's job is an estimate landing on another waveform's second, so
the neighbour is now a waveform.  A companion test pins the case the new
key allows: an estimate beside a histogram at its second is stored
alongside it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 21:30:51 -05:00
serversdownandClaude Opus 5.5 ea2dfc21b7 feat(db): events are identified by unit + time + type (#51)
The events table was UNIQUE(serial, timestamp): one event per unit per
second.  A unit records a waveform and a histogram in the same second
legitimately -- 209 times in prod's 2026-09-30 store once histograms
carry Blastware's start -- so the key is now (serial, timestamp,
record_type).  Agreed with Brian 2026-11-03.

- Migration 3 rebuilds the table from its own current definition with
  only the key swapped, in one transaction: every column, row and id is
  kept (Terra-View reads rows by id) and the indexes are recreated.
  Migration 1's check no longer mistakes the new key for a missing one.
- The upsert, the estimate guard and the restamp match on the type too.
  The restamp also re-types a file's own row in place: before v0.33.0 a
  row's type came from the filename, and a re-import under the file's
  own type must not add a second row.
- An untyped event still refreshes the untyped row at its second (a
  UNIQUE key treats NULLs as distinct).
- scripts/repair_unknown_serials.py checks the new key.

No time changes yet: that is the next commit, and they ship together.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 21:29:46 -05:00
serversdownandClaude Opus 5.5 1bb15573fc feat(s3): assemble a settings read into the 2,090-byte block
Unescape each 1A data frame, take data[11:], drop the one non-content
byte that starts every frame but the last: 2,090 bytes headed by
N = 2090, Series IV's 0x1A layout.  Measured on BE9441's 10-26
recording (12 reads, both frame patterns); the read after each
Blastware write equals the image written.  read_compliance_content is
strict (a missing frame raises) and unjudged (a monitoring unit's
device-info answer comes back for the caller to recognise).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:28:04 -05:00
serversdownandClaude Opus 5.5 e3a77e421d docs(spec,plan): phase 5 -- the units' own limits, from Instantel's manuals
Brian: use the actual unit limits, not what has been used in the past.
Trigger 0.005-10 in/s in 0.001 steps (capped by the range), record time
1-90 s (Micromate) or the MiniMate manual's 1 MB table by sample rate
(13 s in Histogram Combo), job number 1-9999.  The read-back reports any
value a unit does not take.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 19:30:07 -05:00
serversdownandClaude Opus 5.5 71609e71ab docs(plan): phase 5 -- changing a unit's settings by serial
Seven tasks: the Series 3 read assembly, one settings codec for both
series, the Micromate schedule read, each series' audited change, the
route (and the legacy write retired), and the page.  Spans measured
from 75,958 Blastware reports.  Bench after the final review, Brian's
go per send.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 18:51:53 -05:00
serversdownandClaude Opus 5.5 dba891d504 docs(spec): phase 5 -- the Micromate schedule check; work hours is next
A scheduled start loads the setup it names, so a change to another
setup would be undone at the next start: read schedule.dat and refuse
that case.  Configurable work-hours recording, without THOR's scheduler
or setup files, is the agreed next project.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 18:35:29 -05:00
serversdownandClaude Opus 5.5 e8242aaadc docs(changelog): Unreleased -- group B in the protocol reference
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 18:30:08 -05:00
serversdownandClaude Opus 5.5 19719bdd96 merge: group B in the protocol reference (D.6.9), #50 retracted
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 18:29:54 -05:00
serversdownandClaude Opus 5.5 2c4ae8c4ef docs: group B in the protocol reference (D.6.9), #50 retracted
Interval size (k - 40), the stop (footer ts2), frequency = (sample rate
/ 2) / half-period with Blastware's words for N/A, >100 / >200 and
<1.0, and each interval's vector sum with its OORANGE rule.  The old
fixed-512 frequency formula is retracted in place.  CLAUDE.md and the
README roadmap follow: 34 of 88.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 18:29:53 -05:00
serversdownandClaude Opus 5.5 42933f76df docs(changelog): Unreleased -- histogram interval detail, #50
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 18:29:00 -05:00
serversdownandClaude Opus 5.5 31231d7e81 merge: a histogram's interval detail -- frequencies (#50), vector sums, interval size, stop (group B)
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 18:28:27 -05:00
serversdownandClaude Opus 5.5 0238e4d3f3 docs(spec): phase 5 -- changing a unit's settings by serial
Brian's intent (UM6047's trigger, notes typos, the backup unit), the
flow, the first-version fields, and what is measured: Series 3's
compliance block has Series 4's 0x1A layout; a whole 1A read assembles
to the 2,090 bytes Blastware writes back (exact on both 10-26 writes);
Blastware writes 00 00 at [26:28] and a per-unit constant after the
block.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 18:12:14 -05:00
serversdownandClaude Opus 5.5 13f2769736 feat(decode_check): an OORANGE interval vector sum is saturation
Blastware prints OORANGE for an interval's vector sum when it exceeds
the range in an interval where Blastware also clamped a channel: 17 / 17
DL2 cells, SFM's sum 10.01 .. 17.33 in/s (sqrt 3 x 10.005).  The
saturation carve-out now covers intervals.Geo PVS in/s with that rule,
per interval, as it already did for PeakVectorSum.  The 4 other cells
left mismatching sit 4e-6 past a rounding boundary (Blastware's
arithmetic is a hair lower) and stay mismatches.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 18:02:51 -05:00
serversdownandClaude Opus 5.5 2b698e74cf feat(decode): a histogram's interval detail -- frequencies (#50), vector sums, interval size, stop
Group B of the file-only decode, measured on DL2 2026-11-03:

- Frequency = (sample rate / 2) / half-period: 527,915 / 527,915 cells
  at 1024 sps and 1,725 / 1,725 at 2048.  #50: half_period_to_hz took a
  fixed 512 and halved every 2048-sps frequency; it now takes the rate
  (default 1024).  Blastware prints 'N/A' for a half-period of 0, '>100'
  ('>200' at 2048) at 5 samples or fewer, '<1.0' below 1 Hz.
- Each interval's vector sum, sqrt(PVS^2) at the event's range:
  771,354 / 771,354.
- Interval size: uint16 seconds at k - 40 (Series IV [8:10]).
- Stop: the footer's (2,995 / 2,999 sampled; 4 print a second earlier).

Event gains histogram_interval_sec, interval_half_periods, interval_pvs
and stop_time; the .h5 gains /intervals/half_period/<ch>,
/intervals/pvs_ips and a histogram_interval_sec attr.  The decoder walks
a histogram once (histogram_codec.channels_from_records) and takes the
event's PVS from the same records.  The checker compares each interval
column, number or Blastware's word; the test that pinned Tran Freq Hz
as blank now pins the match.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 17:34:27 -05:00
serversdownandClaude Opus 5.5 67b3ef8d0a docs(changelog): Unreleased -- group A in the protocol reference
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 17:24:40 -05:00
serversdownandClaude Opus 5.5 1309f93fa9 merge: group A in the protocol reference, and the three meanings of mic 'units'
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 17:24:29 -05:00
serversdownandClaude Opus 5.5 8f75be5f72 docs: group A in the protocol reference, and the three meanings of mic 'units'
Protocol reference:
- D.6.8 (new): the identity block (SUB FE's: serial, firmware, DSP version,
  calibration date and 'by', model; battery), the trigger-source bitmask
  in the embedded event record, and the trigger settings (sources, stop
  mode, per-channel levels, mic type) with their DL2 counts.  The
  histogram 'terminal tail' 9c 06 00 42 looks like 9c 06 00 + the
  serial's B (inferred).
- D.6.6: recorded data vs report units vs unit peaks, with the
  MiniMate Plus (s3.9.7) and Blastware (s4) manual sections.  Where the
  unit stores its own Microphone Units is unmeasured; a keypad test is
  proposed.
- D.6.9 (was D.6.7): refreshed, 28 of 88.

CLAUDE.md 'Where things stand' and the README roadmap follow.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 17:24:21 -05:00
serversdownandClaude Opus 5.5 06a4be9445 docs(changelog): Unreleased -- identity, battery and trigger settings from the file
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 17:23:07 -05:00
serversdownandClaude Opus 5.5 3ee9923f81 merge: a Blastware file's identity, battery and trigger settings (group A)
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 17:22:34 -05:00
serversdownandClaude Opus 5.5 6c2dbf0463 docs(decode_check): the units carve-out cites Instantel's manuals
Both settings are documented: the unit's Microphone Units (MiniMate Plus
manual s3.9.7, keypad Right Arrow + Setups: psi(L) / dB(L) / Pa(L)) and
Blastware's report preference (Blastware manual s4, Preferences > Units
and Channel).  The report follows Blastware's, as DL2's fleet-wide
switches showed.  Where the unit's own setting is stored is unmeasured.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 17:15:28 -05:00
serversdownandClaude Opus 5.5 cbce00f8e1 merge: dev into feat/series4-sfm-parity -- the decode checker's file-only fields (job number, codec by STRT[18], last-26-byte footer)
Brings be5bab4 and its history from the decode checker's branch: a Blastware
file's job number; decode_blastware_bytes choosing the codec by STRT[18] and the
histogram layout check by peak <= PVS <= sqrt(3) peak; the footer as the file's
last 26 bytes (no day-late histograms); docs (reference Appendix D.6, the
file-only status).

Conflicts, both kept whole:
- CLAUDE.md: this branch's 'Narrowed 2026-10-26' 5A block stays, followed by
  dev's 'Open, not blocking' line (the 8x sensitive-range item struck out --
  resolved by the file's range).
- docs/instantel_protocol_reference.md (CRLF, byte-safe): the change-log rows in
  date order -- dev's 2026-11-03 and 2026-11-02, this branch's 2026-11-03
  (call home), 2026-10-29 and 2026-10-27 (#46, this branch only).

Suite on the merged tree: 1399 passed, the 16 known failures.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 15:34:59 -05:00
serversdownandClaude Opus 5.5 2e1c2ba21f docs: phase 4 bench -- call-home on/off on both series, idle and monitoring
Benched 2026-11-03 on UM20147 and BE9441 (each on its own modem, one send per
go): idle, a no-op, off and on all acked, read back and confirmed on each unit's
menu; UM20147 accepts 0x00 at [5].  Monitoring, neither series takes a change: a
MiniMate answers 0x2C with its device-info block, a Micromate acks and ignores
('Feature disabled while monitoring').  Series 4 [118:120] is a function of the
block's content -- XOR 0x6D7D per bit-0 flip on two units, not a nonce.  A stop's
call-in reached THOR when the ring followed the ack.  UM20147's clock is an hour
ahead (DST).  Spec, both protocol references (Series III: a CRLF row), CLAUDE.md.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 15:32:51 -05:00
serversdownandClaude Opus 5.5 789e24be50 fix(sfm): the top bar names a Micromate's firmware line; a stale overlay comment
- The page's top bar Firmware read '—' for a Micromate: Batch 2 gave the Device
  tab's card firmwareLabel() but not populateDeviceBar.  Seen at the bench
  2026-11-03; checked in jsdom ('—' before, 'Thor line (version not read)' after).
- save_imported_bw's overlay comment said the waveform codec was undecoded and
  gave +-10 in/s; the overlay now stays because production keeps a paired
  Blastware report as the record until the file-only decode has no blanks
  (flagged by the decode-checker session).  Comment only.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 15:32:02 -05:00
serversdownandClaude Opus 5.5 f35845d403 fix(sfm): a Micromate's call-home is refused while monitoring, and only a real call-home block is ever edited
Measured at the bench 2026-11-03 (UM20147): monitoring, a Micromate returns its
real call-home block and ACKS a call-home write, but does not apply it -- three
read-backs unchanged, and its own menu says 'Feature disabled while monitoring'.
SFM now refuses up front (UnitStateUnknown, 409: '... is monitoring -- a Micromate
ignores call-home changes while monitoring ...; stop monitoring first -- nothing
sent'), dry run included, instead of sending a write the unit ignores.

And the block must be the call-home block: micromate.writes.is_call_home_content
checks its header is its own length (00 7C, N = 124 -- 00 7C DC on every read,
UM12947 and UM20147).  plan_call_home_enabled refuses any other 126 bytes, the
change refuses before sending, and call_home_state says why (enabled = None).
At the bench this was checked by eye before the monitoring write.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 15:32:02 -05:00
serversdownandClaude Opus 5.5 5326e99ac2 fix(sfm): a monitoring MiniMate's call-home says 'stop monitoring first', not 'unknown(0x6E)'
Measured at the bench 2026-11-03 (BE9441): while monitoring, a MiniMate answers
the 0x2C call-home read with its DEVICE-INFO block ('Instantel', 'MiniMate Plus',
its serial) -- as it answers 1A -- and idle again, minutes later, the call-home
block.  SFM writes back only a block it just read, so a monitoring MiniMate's
call-home cannot be changed; the change core already refused (byte 5 read as
'unknown(0x6E)', nothing sent), but said so cryptically.

- minimateplus.protocol.is_call_home_block(raw): the block starts with its own
  length 0x7C and is N (or N + 2) bytes unescaped; the device-info block fails it.
- The Series-3 change raises UnitStateUnknown (409) with 'did not return its
  call-home settings -- a MiniMate answers the call-home read with its
  device-info block while monitoring; stop monitoring first ... nothing sent',
  for a dry run too.  call_home_state returns enabled = None with that reason.
- The page's callHomeRows shows the reason in place of 'Unknown (byte 5 = ...)'.

A blind write while monitoring stays untested on purpose.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 14:19:19 -05:00
serversdownandClaude Opus 5.5 8d5a9987c9 fix(decode_check): compare a mic level in the unit it is printed in
K441LA17.IN0W's report says Units 'in/s and psi(L)' yet prints
MicTriggerLevel '125.0 dB(L)'.  The value states its own unit, so that
is the one compared; the report's Units is the fallback.  It was the
only MicTriggerLevel mismatch in DL2 (SFM's 0.005158 psi is 125.0 dB).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 14:02:27 -05:00
serversdownandClaude Opus 5.5 6c2eda5f63 feat(decode): a Blastware file's identity, battery and trigger settings
Group A of the file-only decode, every field matched against every DL2
report (2026-11-03):

- Identity block before the setup name, what the live read gets from
  SUB FE: serial k-202, firmware k-147, DSP version k-138, calibration
  date k-132 + 'by' k-128, manufacturer k-94, model k-72, firmware
  minor k-193.  Event.device_info (DeviceInfo gains calibration_date /
  calibrated_by).  Serial, Version and Calibration 69,983 / 69,983.
- Battery: uint16 hundredths of a volt at k-190 (Event.battery_volts).
  69,729 exact; the other 254 are Blastware rounding half up.
- Trigger source: the two bytes between the embedded event record's
  lead and fe 80, a bitmask (0x01 Tran 0x02 Vert 0x04 Long 0x08 MicL
  0x200 Manual): 6,493 / 6,493.  Event.triggered_by.
- Trigger settings in Series IV's 0x1A layout: sources bitmask k-19,
  stop mode k-31 (0 = Fixed), each channel's float32 level at
  label+30 (geo in/s, mic psi), mic type code at MicL+4 (2 = Linear
  Weighting).  Geo level 6,447 / 6,447, mic 4,403 / 4,403; Blastware
  prints a level when its channel is a trigger source and the event
  was not Manual.  The mic level's dB uses 6895 Pa/psi (4,272 / 4,272
  against 4,271 at 6894.757).
- .h5 attrs for all of them (additive).
- Checker: SFM's side reports the ten fields; the mic trigger level
  follows the report's dB/psi.  Carve-out
  units-is-a-display-preference: dB or psi is Blastware's PC setting
  when it wrote the report -- DL2's reports switch fleet-wide in 61
  clean runs by write time, and no byte of the file separates them.
  Two tests that pinned BatteryLevel / Calibration as blank now pin the
  match.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 13:38:39 -05:00
serversdownandClaude Opus 5.5 be5bab4787 docs(changelog): Unreleased -- where file-only decoding stands
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 13:06:19 -05:00
serversdownandClaude Opus 5.5 fc7ce5df02 merge: where file-only decoding stands, and that prod's ASCII overlay is scaffolding
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 13:06:07 -05:00
serversdownandClaude Opus 5.5 5a089671e8 docs: where file-only decoding stands, and that prod's ASCII overlay is scaffolding
CLAUDE.md 'Where things stand' now says plainly how prod uses a paired
Blastware ASCII report (save_imported_bw overlays its peaks, notes,
sample rate and record time onto SFM's decode), that only report-less
events run on the decoder alone, and that the overlay is scaffolding to
retire at step 3 of the plan.  The checker status is brought up to dev:
18 of 88 fields, the remaining groups A-F in the proposed order.

README roadmap: the same framing and progress.

Protocol reference:
- D.3.3: the footer is the file's last 26 bytes; footer[18:24] is not
  fixed (retracted).
- D.6.1: STRT[18] picks the codec.
- D.6.3: the job number.
- D.6.5: the PVS^2 high word is non-zero above 1.28 in/s (retracted
  'reads 0000'); the peak/PVS consistency check; Blastware's Number of
  Intervals is the monitoring time / the interval.
- D.6.7: refreshed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 13:05:58 -05:00
serversdownandClaude Opus 5.5 fcacc8f28c docs(changelog): Unreleased -- the footer is the file's last 26 bytes
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 13:04:13 -05:00
serversdownandClaude Opus 5.5 e227448483 merge: a Blastware file's footer is its last 26 bytes -- no more day-late histograms
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 13:03:29 -05:00
serversdownandClaude Opus 5.5 e1e8a851c8 docs: where the 1995 default-clock events come from
Brian's account: units come back from calibration with the internal
battery unplugged, so a comms-test trigger before the date is set
carries the default.  DL2 holds 17 such events on 6 units, all within
1995-09-01 12:02 .. 09-03 11:24.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 12:12:02 -05:00
serversdownandClaude Opus 5.5 8a40eb638a fix(decode): a Blastware file's footer is its last 26 bytes -- no more day-late histograms
Every DL2 file ends in a valid footer: 0e 08 and two valid times on
70,041 / 70,041.  The decoder took the first '0e 08 + plausible year'
instead, and 14 files also hold an earlier record, ~1.1 KB before the
end, with the stop time followed by zeros:
- a histogram started at its own stop -- a day late on BE9558's daily
  histograms (K558L9XP.FK0H: 2025-10-08 19:10:01 for Blastware's
  2025-10-07 19:14:08); T003LCYV.JD0H got no time at all;
- a waveform lost its stop, so the trigger was never computed and the
  stop was stamped instead (K440I4LG.JK0W: 11:14:12 for 11:14:08).

The last 26 bytes are now taken when they are a footer; otherwise the
old search stands unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 12:10:44 -05:00
serversdownandClaude Opus 5.5 dd9f6dde7a docs(changelog): Unreleased -- histograms go to the histogram codec
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 11:32:57 -05:00
serversdownandClaude Opus 5.5 f768ec42f3 merge: histograms go to the histogram codec, and a loud interval no longer hides a short one
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 11:32:01 -05:00
serversdownandClaude Opus 5.5 9820a5389f docs(spec): phase 4's final review -- what it caught before the bench
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 17:24:13 -05:00
serversdownandClaude Opus 5.5 9e03b3f0ab fix(sfm): a Micromate in an unknown run state gets no call-home write, and a lost ack keeps its snapshot (phase-4 review)
- s4_change_call_home's read_state now returns an unknown(0xNN) run state as
  it is, so the change core refuses it (UnitStateUnknown, nothing sent), as
  start/stop already does; it checked only for calling_home.
- run_change records the snapshot on the lost-ack path too: after an ack is
  lost, what the unit now holds (and, on Series 4, whether [118:120] moved) is
  what tells whether the write landed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 17:23:59 -05:00
serversdownandClaude Opus 5.5 bdd76b8f74 fix(minimateplus): a built call-home image is framed once, never unescaped again (phase-4 review)
call_home_image returns the unescaped N + 2 image, but the send path handed it
to write_call_home_config, whose write_image unescapes again -- and unescaping
is not idempotent: a real 0x10 before 02/03/04 loses its 0x10.  A call-in time
of 16:02-16:04 (hour 0x10) is exactly that.  One such time made the send refuse
before the wire yet audited as 'sent, acknowledgement lost'; two made it send a
block shifted by two bytes from [101] (num_retries and the time fields wrong).
The Blastware-frame test could not see it: it checked the image builder, not
the bytes the protocol framed.

- MiniMateProtocol.write_call_home_image(image) frames a built image once
  (0x7E, ack 0x81, 0x7F, ack 0x80), raising ImageRefused before any byte when
  it is not a whole block; write_call_home_config (the legacy multi-field path)
  is write_image once + that.  Its stale 127-byte docstring is gone.
- MiniMateClient.write_call_home_image uses it.
- The Series-3 change passes is_refusal=ImageRefused, so a pre-wire refusal is
  audited as nothing sent (sent = 0), not as a lost ack.

Tests drive the real client -> protocol over a stub answering with BE11529's
recorded acks: the unit's own read, a 16:02 time, and 16:03 + 16:04 all go out
exactly as built; a short image is refused with nothing written.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 17:23:59 -05:00
serversdownandClaude Opus 5.5 3e1d42e04b docs: phase 4 built -- call-home enable/disable by serial; bench questions
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 17:07:36 -05:00
serversdownandClaude Opus 5.5 51e7dddcb3 test(micromate): corpus counts are floors, and 0x71 is the over-the-ceiling example
Two test-side breaks, found by the full suite after phase-4 task 6:
- test_micromate_framing's three whole-session tests pinned exact counts of a
  gitignored corpus (bridges/captures/9-24-26 - micromate2, a symlink into the
  main checkout).  The full copy of the BW VM's captures on 2026-11-02 added
  sessions: 287 responses / 241 reads / 287 requests, every one passing the same
  per-frame checks.  The counts are now floors (>= 251 / 218 / 251), so a lost
  file still fails and a grown corpus does not.
- test_micromate_opcodes' beyond-the-ceiling permit took 0x7E, enableable since
  the call-home commit (eeb55ef); 0x71 (the setup write, phase 5) replaces it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 17:07:04 -05:00
serversdownandClaude Opus 5.5 84c142f36c feat(sfm): the page's Call Home tab by serial -- state and audited On / Off (phase 4)
device_routing.js (Node-tested): call_home_state / call_home_on / call_home_off
routes (serial required); controlsFor gains callHomeChange (by serial, a
confirmed Series 3 or 4) and callHomeRead now covers a Series 4 by serial;
serialPanes gains callHomeForm / callHomeBox; callHomeRows renders the switch
(On / Off / 'Unknown (byte 5 = 0xNN)'), dial string and series;
changeErrorText takes the whole label ('Start monitoring', 'Enable call-home').

sfm_webapp.js: by serial the Call Home tab hides the legacy multi-field form
(Series 3 by host only) and shows the unit's switch with On / Off.  Each asks
confirm(), sends one audited change, reports it with changeSummary /
changeErrorText, then re-reads quietly so the change's own result stays on
screen.  A different unit's switch is never left showing.  The new buttons are
wired with addEventListener, not onclick= (no inline JS).

Checked in jsdom against the real page: placeholder, read, Off (confirm, the
disable route, 'confirmed -- enabled -> disabled'), a serial edit clearing it,
legacy mode unchanged, no script errors.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 17:05:00 -05:00
serversdownandClaude Opus 5.5 06fa56db09 feat(sfm): call-home state and enable/disable by serial -- GET /device/call_home/state, POST /device/call_home/{enable,disable} (phase 4)
- DeviceAccess.call_home_state (a read) and set_call_home (change=True: never
  retried, audit required for a live change, dry run without one), routed by
  series like start/stop.  A config write is read back on its own window: up
  to 3 reads, 1 s apart, not the monitoring one.
- Routes, serial required (422 without), all three serial-aware: the state as
  a dict; enable / disable through _change_response, so their statuses are
  start/stop's and an unconfirmed change carries sent + audit_id.  The legacy
  GET / POST /device/call_home are unchanged (a Micromate serial is still
  refused there, 501).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 17:01:14 -05:00
serversdownandClaude Opus 5.5 453d42e32a test(s3): SFM's call-home write equals Blastware's, frame for frame -- opens the live send
Ground truth: Blastware changing BE11529's call-home settings on 2026-04-20
(Remote Access -> Setup Unit), paired raw files of what it sent and what the
unit answered: the read, the enable (read 0x00 -> wrote 0x01), the disable
(read 0x01 -> wrote 0x00).  From the unit's own read before each write, SFM's
0x7E frame (call_home_image + build_bw_write_frame) is Blastware's byte for
byte -- nothing but byte 5 differs from the read -- and the 0x7F confirm too.
Mutation-checked: inverting the byte SFM writes fails the test.

S3_CALL_HOME_FRAME_VERIFIED is now True; the gate stays tested shut by
monkeypatch, and a test pins that its comment names this proof.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 16:59:15 -05:00
serversdownandClaude Opus 5.5 8612cd9df7 feat(sfm): Series-3 call-home state and audited enable/disable, live send gated until its frame is verified (phase 4)
- minimateplus.protocol: call_home_enabled(raw) reads byte 5 of the UNESCAPED
  0x2C payload (0x01 on / 0x00 off, measured 2026-04-20; anything else None --
  bench finding #1's lesson: an escaped byte before it would move the raw
  index); call_home_image(raw, enabled) is write_image's N + 2 image with byte 5
  set and everything else as read, refusing a byte 5 never measured.
- MiniMateClient.read_call_home_raw() / write_call_home_image(image) (0x7E then
  0x7F, each ack checked, never retried).
- Series3Adapter.call_home_state (wake, then 0x2C; no serial read, like status)
  and change_call_home: the shared change core with a connect() identity check,
  state 'enabled' / 'disabled' / 'unknown(0xNN)' (unknown sends nothing), the
  plan showing both exact frames, a snapshot of both unescaped images.
- S3_CALL_HOME_FRAME_VERIFIED = False: a live change is refused (501) before any
  connection until the frame is reproduced from Blastware's (next commit).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 16:57:55 -05:00
serversdownandClaude Opus 5.5 eeb55effe9 feat(sfm): Series-4 call-home state and audited enable/disable (phase 4)
- micromate: ENABLEABLE_WRITES gains 0x7E/0x7F (the call-home write and its
  confirm; spec row 9, enable/disable only); MicromateClient.get_call_home_content()
  returns the 126-byte 0x2C content.
- sfm/device_access: CallHomeState (serial, series, enabled, dial_string, detail
  with byte5 and the whole block); s4_call_home_state reads bit 0 of [5] and the
  dial string at [6:46]; s4_change_call_home runs the shared change core with
  micromate.writes.plan_call_home_enabled -- built from the read run_change made
  just before, and that same plan is the one sent.  A unit calling home (run
  state 0x03) is refused, nothing sent.  The read-back judges the edited bit
  only; the snapshot records both blocks and every changed offset -- [118:120]
  is unit-maintained and always moves.
- The write-ceiling tests take 0x71 (the setup write, phase 5) as their
  over-the-ceiling example now that 0x7E is enableable.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 16:56:04 -05:00