Compare commits
62
Commits
No files matched your search
+345
-1
@@ -4,9 +4,125 @@ All notable changes to seismo-relay are documented here.
|
||||
|
||||
---
|
||||
|
||||
## Unreleased
|
||||
## v0.34.0 — 2026-11-04
|
||||
|
||||
**SFM reaches Series-4 parity, and reads most of Blastware's report from the
|
||||
event file alone.**
|
||||
|
||||
Two lines of work ship together.
|
||||
|
||||
**Series-4 parity** (`feat/series4-sfm-parity`). One device door, by serial,
|
||||
for both series. Each change is audited, identity-checked, sent once and read
|
||||
back. Benched on BE9441 and UM20147.
|
||||
- reads and downloads
|
||||
- start / stop monitoring
|
||||
- call-home on / off
|
||||
- settings changes (preview → send → read back)
|
||||
|
||||
It also fixes MiniMate request framing (#46) and the 5A walk across a 64 KB
|
||||
page.
|
||||
|
||||
**The file-only decode, groups A–D.** 47 of Blastware's 88 report fields now
|
||||
match on every DL2 event, about 6 before v0.33.0. Eight more match on all but
|
||||
one or two of 6,524 waveforms.
|
||||
- **Fixed:**
|
||||
- Sensitive-range events no longer read 8× high
|
||||
- histograms the waveform codec had claimed, and short histograms with a
|
||||
loud interval, now decode
|
||||
- histograms are no longer a day late
|
||||
- every histogram's start and stop are Blastware's own (#51), not a second
|
||||
early
|
||||
- interval frequencies follow the sample rate (#50)
|
||||
- **New from the file:**
|
||||
- the job number
|
||||
- the unit's serial, version, calibration date and battery
|
||||
- the trigger source and levels
|
||||
- each interval's frequencies, vector sum and time
|
||||
- the peak dates and times
|
||||
- a waveform's time of peak and peak acceleration
|
||||
- **Events are identified by unit + time + type:** a waveform and its histogram
|
||||
may share a second.
|
||||
|
||||
Prod still overlays a paired ASCII report onto the decode. That overlay is the
|
||||
plan's step 3 and is not part of this release.
|
||||
|
||||
⚠ **This release migrates the events table and owes a backfill that moves every
|
||||
Series-3 histogram's stored time by one second.** See *Migration*.
|
||||
|
||||
### Fixed
|
||||
- ✅ **MiniMate requests and config writes are framed as Blastware frames them
|
||||
(#46; `feat/series4-sfm-parity`).**
|
||||
- Every request escapes 02 / 03 / 04 / 10.
|
||||
- A config write is an ordinary escaped request carrying a whole block (as
|
||||
read, plus two bytes). All four blocks are checked before the first frame.
|
||||
- SFM's frames equal Blastware's in the 2026-04-20 and 2026-10-26 captures.
|
||||
Benched on BE9441 2026-11-04.
|
||||
- ✅ **The 5A walk crosses a unit's 64 KB page.** The walk is 32-bit linear
|
||||
(the CLAUDE.md "KNOWN BUG"); BE9441's page-crossing events rebuild Blastware's
|
||||
own files byte for byte.
|
||||
- A one-event download is whole or an error.
|
||||
- A non-first event's stream has no metadata pages.
|
||||
- **A MiniMate settings read is assembled as content** (measured at the bench
|
||||
2026-11-04).
|
||||
- Unescape each 1A frame and drop the one non-content byte that starts every
|
||||
frame but the last: 2,090 bytes headed by N = 2090.
|
||||
- The read takes exactly the length it asked for. When a reply's checksum
|
||||
byte is itself escaped (about 1 frame in 85), the parser leaves its 0x10 in
|
||||
the data. It hit the first live read; the recordings never had it. The
|
||||
waveform-data read now trims it too.
|
||||
- **A live download is held to its record type (#51):** a same-second
|
||||
waveform / histogram twin is no longer skipped as "already stored". An untyped
|
||||
row at that second still counts as stored.
|
||||
- Smaller wire fixes from the parity benches:
|
||||
- SUB 0x15's serial is cut at its first NUL.
|
||||
- 0x1C reads a histogram run as monitoring.
|
||||
- A MiniMate that boots on connect is waited for.
|
||||
- A start's read-back waits out the sensor check and wakes the unit.
|
||||
- A built call-home image is framed once.
|
||||
|
||||
- ✅ **#51: events are identified by unit + time + type, and histograms take
|
||||
Blastware's times.**
|
||||
- **The new key.** The events table was `UNIQUE(serial, timestamp)`, one
|
||||
event per unit per second. A waveform and its histogram share a second
|
||||
legitimately: 209 times in prod's 2026-09-30 store. The key is now
|
||||
`UNIQUE(serial, timestamp, record_type)` (agreed with Brian 2026-11-03).
|
||||
- **Migration 3** rebuilds the table from its own definition with only the
|
||||
key swapped, in one transaction. Every column, row and id is kept, and
|
||||
the indexes are recreated.
|
||||
- **Lookups:** the upsert, the estimate guard and the restamp match on
|
||||
type. The restamp also re-types a file's own row in place. An untyped
|
||||
event still dedups against an untyped row.
|
||||
- **Histogram times.** A histogram's start and stop now come from its own
|
||||
event record (lead `00 28 05 00`, source `04 00`, marker `fe f5`). That is
|
||||
Blastware's Histogram Start and Stop on 63,490 / 63,490 DL2 histograms; the
|
||||
footer's start was a second early on 97%. Without a validated record, the
|
||||
footer stands and the decoder logs a decode problem.
|
||||
- **Interval times and peak times follow:**
|
||||
- each interval's printed time is its end, start + (i + 1) × interval,
|
||||
capped at the stop (2,308,524 / 2,308,524 rows; `interval_times`)
|
||||
- each peak's date and time is its interval's
|
||||
- **Decode checker:** 760,410 comparisons fixed, 0 regressions, **47 of 88**
|
||||
fields fully match (was 34). Histogram start and stop times, interval
|
||||
times and the ten peak date/time fields match every DL2 histogram.
|
||||
- **Rehearsed on a copy of prod's 2026-09-30 snapshot (15,432 events):**
|
||||
- The migration kept every row identical, rebuilt the indexes and passed
|
||||
the integrity check, in 0.27 s.
|
||||
- `backfill_sidecars.py`: 11,944 files, 0 errors. 9,852 Series-3
|
||||
histograms moved +1 s in place, with no id lost and review state
|
||||
untouched. The 209 same-second pairs coexist, and 0 collisions were
|
||||
refused. (It also created 341 rows for store files that never had one:
|
||||
the known one-time behaviour, not duplicates.)
|
||||
- `backfill_event_shape.py`: exit 0, `cleared_stale` 0.
|
||||
- ⚠ **Schema migration + codec change.** SFM migrates the events table by
|
||||
itself on first start: back up `seismo_relay.db` first. The release
|
||||
backfill (`backfill_sidecars.py` then `backfill_event_shape.py`) moves
|
||||
every Series-3 histogram's stored time by one second, in place.
|
||||
- Terra-View pairs twins by peak values and reads rows by id: no change
|
||||
needed there.
|
||||
- Note for Terra-View's changelog: Series-3 histograms move forward one
|
||||
second, so an event can cross a deployment-window edge.
|
||||
- Three tests that pinned the old footer start now pin the record's. The
|
||||
estimate-guard test's neighbour is now the same type.
|
||||
- **A Blastware file's geophone range comes from its setup, so Sensitive
|
||||
events no longer read 8× high.**
|
||||
- **Where it is:** in the setup's channel blocks, the byte 29 after each
|
||||
@@ -92,6 +208,154 @@ All notable changes to seismo-relay are documented here.
|
||||
change.
|
||||
|
||||
### Added
|
||||
- **Series-4 parity in SFM: everything by serial, for both series**
|
||||
(`feat/series4-sfm-parity`, merged 2026-11-04; spec
|
||||
`docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md`).
|
||||
- **One door, `DeviceAccess`.**
|
||||
- A unit is addressed by its serial: UM is Series 4, BE / BA is Series 3.
|
||||
The unit's own answer is checked before anything is sent.
|
||||
- A Micromate's line is held between requests and released when idle or
|
||||
on RADIO RING.
|
||||
- One connection per unit; 423 while busy.
|
||||
- **Reads, both series:** `GET /device/info`, `/device/monitor/status`,
|
||||
`/device/settings`, `/device/events` and `POST /device/events/download`.
|
||||
- A download is stored as the watcher stores it, through the Blastware /
|
||||
IDF import path, typed.
|
||||
- It never overwrites a stored event.
|
||||
- SFM's MiniMate files carry Blastware's W/H type letter.
|
||||
- **Changes, both series, each audited** (a `device_commands` row per
|
||||
attempt), identity-checked, sent once, never retried, read back:
|
||||
- start / stop monitoring;
|
||||
- call-home on / off: `GET /device/call_home/state`,
|
||||
`POST /device/call_home/{enable,disable}`;
|
||||
- **settings**, `POST /device/settings/change`.
|
||||
- **Settings, in detail:**
|
||||
- A preview (dry run) shows old → new and returns a revision; a live
|
||||
change must carry it, covering the unit's block and the changes asked for.
|
||||
- Fields: record mode, sample rate, histogram interval, record time,
|
||||
geophone trigger, the four notes, job number and its report flag, and
|
||||
(MiniMate) range and alarm.
|
||||
- Limits are the units' own, from Instantel's manuals, checked on the
|
||||
block that would result.
|
||||
- Refused before anything is sent: a monitoring unit, a stale preview, a
|
||||
Micromate on its factory setup, or one whose schedule would load another
|
||||
setup. SFM reads `schedule.dat`, read-only.
|
||||
- **One settings codec for both series** (`micromate/setup_fields.py`): a
|
||||
MiniMate's settings block is Series IV's `0x1A` layout. All 11 Blastware
|
||||
compliance writes reproduce from the block before them.
|
||||
- **The page:**
|
||||
- units by serial, with the series badge from the unit's own answer;
|
||||
- the events list and download, start / stop, the Call Home tab;
|
||||
- the Config tab's Preview → Send → "the unit now holds";
|
||||
- page JavaScript in `sfm/static/`, tested through Node (no inline JS).
|
||||
- **Benched on BE9441 and UM20147:** phase 4 on 2026-11-03, phase 5 on
|
||||
2026-11-04. Every change was acknowledged, read back and confirmed on the
|
||||
unit's screen; both units were restored byte for byte.
|
||||
- ⚠ A MiniMate's open setup menu loses a remote change when the operator
|
||||
presses Cancel or Save (the menu writes its whole-block copy back). The
|
||||
preview warns.
|
||||
- ⚠ The Micromate scheduler switch is in no block SFM reads, so a leftover
|
||||
schedule blocks a change even with the scheduler Off.
|
||||
- ⚠ **Operational:** additive schema only. SFM creates `device_commands`, or
|
||||
adds `sent` / `states` to an older one, on first start; this branch does not
|
||||
touch `events`. No `TOOL_VERSION` bump and no backfill from this branch:
|
||||
event decoding is unchanged. Production ingest (the watchers) is untouched;
|
||||
the new device routes are used only from SFM's page and API.
|
||||
- **A waveform's time of peak, vector-sum time and peak acceleration** (group D,
|
||||
part 1 of the file-only decode). Measured on DL2 2026-11-04.
|
||||
- **Time of peak** = (first peak sample − pre-trigger samples) / sample rate,
|
||||
per channel including the mic.
|
||||
- **The vector sum's time**: the same, on √(T² + V² + L²).
|
||||
- **Peak acceleration** = the largest |v[i+1] − v[i]| × sample rate / g, which
|
||||
the manuals describe as "subtracts two velocity readings and divides the
|
||||
result by the elapsed time between them".
|
||||
- Blastware's g is fitted: every printed acceleration in DL2 bounds it, and
|
||||
together they leave [386.2236, 386.2240] in/s².
|
||||
- That is 9.81 m/s² (386.2205) plus an offset not explained, as with the
|
||||
mic's fitted dB offset. The standard 9.80665 m/s² fits 17,806 of
|
||||
19,479 values; the fitted value fits 19,475.
|
||||
- **`PeakValues` gains** `*_time_of_peak`, `pvs_time` and `*_peak_accel_g`,
|
||||
filled for waveforms only.
|
||||
- **Decode checker:** 52,177 comparisons fixed, 0 regressions. Times of peak
|
||||
are 6,523 / 6,524 on every channel, peak acceleration 6,522–6,523 / 6,524.
|
||||
Every miss is in two 2019 files (O117I1NK.R70W on all channels, S353I5PZ
|
||||
on Vert), not yet explained.
|
||||
- **Not shipped yet:** peak displacement and ZC frequency. They follow the
|
||||
manuals' methods (half the largest half-cycle integral; the half-cycle at
|
||||
the peak), but match only 84% and 46%, so Blastware does something more.
|
||||
- ⚠ **Codec change:** it rides this release's `TOOL_VERSION` bump and
|
||||
backfill. No schema change; the new values are not stored in the DB or
|
||||
the `.h5` yet.
|
||||
- **A histogram's interval detail: frequencies, vector sums, interval size and
|
||||
stop** (group B of the file-only decode). Measured on DL2 2026-11-03.
|
||||
- **Frequency** = (sample rate / 2) / half-period: 527,915 / 527,915 cells
|
||||
at 1024 sps and 1,725 / 1,725 at 2048.
|
||||
- ✅ **Fixes #50.** `half_period_to_hz` used a fixed 512 and halved every
|
||||
2048-sps frequency. It now takes the rate (default 1024).
|
||||
- Blastware prints "N/A" for a half-period of 0, ">100" (">200" at 2048)
|
||||
at 5 samples or fewer, and "<1.0" below 1 Hz.
|
||||
- **Each interval's vector sum**, √PVS² at the event's range.
|
||||
- **Interval size:** uint16 seconds at `k − 40` (Series IV `[8:10]`).
|
||||
- **Stop time:** the footer's.
|
||||
- **`Event` gains** `histogram_interval_sec`, `interval_half_periods`,
|
||||
`interval_pvs` and `stop_time`.
|
||||
- **The `.h5` gains** `/intervals/half_period/<ch>` and `/intervals/pvs_ips`,
|
||||
plus a `histogram_interval_sec` attribute.
|
||||
- **Decoder:** a histogram is now walked once
|
||||
(`histogram_codec.channels_from_records`).
|
||||
- **Decode checker:** 508,080 comparisons fixed, 0 regressions, 34 of 88
|
||||
fields fully match (was 28).
|
||||
- Frequencies on all four channels, interval size and stop date match
|
||||
every DL2 histogram.
|
||||
- Interval vector sum: 63,497 match, plus 17 clipped intervals now under
|
||||
the saturation carve-out. Blastware prints OORANGE when the sum exceeds
|
||||
the range in an interval where it clamped a channel (17 / 17).
|
||||
- 4 cells sit 4e-6 past a rounding boundary and stay mismatches.
|
||||
- 58 stop times are Blastware a second earlier, part of #51.
|
||||
- ⚠ **Codec change:** it rides the next release's `TOOL_VERSION` bump and
|
||||
backfill. The `.h5` additions are additive. No schema change.
|
||||
- **A Blastware file's identity, battery and trigger settings** (group A of the
|
||||
file-only decode). Every field is matched against every DL2 report
|
||||
(2026-11-03).
|
||||
- **Identity block** before the setup name: what the live read gets from
|
||||
SUB FE.
|
||||
- serial `k − 202`, firmware `k − 147`, DSP version `k − 138`, firmware
|
||||
minor `k − 193`
|
||||
- calibration date `k − 132` and "by" `k − 128`
|
||||
- manufacturer `k − 94`, model `k − 72`
|
||||
- Filled into `Event.device_info`; `DeviceInfo` gains `calibration_date` /
|
||||
`calibrated_by`.
|
||||
- Serial, Version and Calibration match 70,042 / 70,042.
|
||||
- **Battery:** uint16 hundredths of a volt at `k − 190`
|
||||
(`Event.battery_volts`), 70,042 / 70,042. Blastware rounds half up
|
||||
(6.25 → "6.3 Volts").
|
||||
- **Trigger source:** the two bytes between the embedded event record's lead
|
||||
and `fe 80`, a bitmask (`0x01` Tran, `0x02` Vert, `0x04` Long, `0x08`
|
||||
MicL, `0x200` Manual). 6,524 / 6,524 (`Event.triggered_by`).
|
||||
- **Trigger settings,** in Series IV's `0x1A` layout:
|
||||
- the sources bitmask at `k − 19`
|
||||
- the stop mode at `k − 31` (0 = Fixed)
|
||||
- each channel's float32 level at label + 30 (geo in/s, mic psi)
|
||||
- the mic type code at MicL + 4 (2 = Linear Weighting)
|
||||
|
||||
Blastware prints a level when its channel is a trigger source and the
|
||||
event wasn't Manual. Geo level 6,484 / 6,484, mic level 4,412 / 4,412
|
||||
(its dB uses 6895 Pa/psi).
|
||||
- **`.h5`:** all of them as attributes (additive).
|
||||
- **Decode checker:** 444,188 comparisons fixed, 0 regressions, 28 of 88
|
||||
fields fully match (was 18).
|
||||
- A mic level is now compared in the unit it is printed in: K441LA17.IN0W
|
||||
prints dB under psi Units.
|
||||
- New carve-out `units-is-a-display-preference` (3,532 events). dB or psi
|
||||
in a Blastware report is that PC's Blastware preference when it wrote the
|
||||
report (Blastware manual §4, Preferences → Units and Channel), not the
|
||||
unit's Microphone Units setting (MiniMate Plus manual §3.9.7). DL2's
|
||||
reports switch fleet-wide in 61 clean runs by write time, and no byte of
|
||||
the file separates them.
|
||||
- Single-value fields are proven for that value only: Version `10.72-8.17`,
|
||||
stop mode Fixed, mic type Linear.
|
||||
- ⚠ **Codec change:** it rides the next release's `TOOL_VERSION` bump and
|
||||
backfill. No schema change.
|
||||
- **A Blastware file's job number, and whether Blastware shows it.**
|
||||
- **Where it is:** the setup block has Series IV's `0x1A` layout here too.
|
||||
The report flags sit at 9 bytes before the setup name, with bit `0x02`
|
||||
@@ -113,7 +377,47 @@ All notable changes to seismo-relay are documented here.
|
||||
backfill (`backfill_sidecars.py` then `backfill_event_shape.py`). The new
|
||||
`.h5` attributes are additive. No schema change, no migration.
|
||||
|
||||
### Removed
|
||||
- **`POST /device/config` and `POST /device/config/project` answer 410**,
|
||||
pointing at `POST /device/settings/change`. Terra-View does not call them.
|
||||
Removed with them, because they wrote a live unit through the encoder #46
|
||||
found wrong:
|
||||
- `MiniMateClient.apply_config`, `set_project_info` and
|
||||
`_encode_compliance_config`;
|
||||
- `poc_set_project.py`, and `experiments.py`'s EXP6.
|
||||
|
||||
### Protocol / Documentation
|
||||
- **The parity benches in both protocol references:**
|
||||
- Series III: the settings write measured end to end, the escaped-checksum
|
||||
stray byte, the keypad menu writing its whole-block copy back, the alarm at
|
||||
channel +38, and `[26:28]` re-set while monitoring.
|
||||
- Series IV: the first setup push, with the unit's CRC equal to SFM's; the
|
||||
schedule read on a real unit; the scheduler switch in none of the blocks.
|
||||
- Spec and plan: `docs/superpowers/specs/2026-11-03-sfm-phase5-settings-design.md`,
|
||||
`docs/superpowers/plans/2026-11-03-sfm-phase5-settings.md`.
|
||||
- **Histogram timing in the protocol reference (D.6.10):**
|
||||
- the histogram's own event record
|
||||
- the interval-time and peak-time rules
|
||||
- "histograms stay on ts1" retracted in place
|
||||
- CLAUDE.md records the unit + time + type key
|
||||
- Docs only.
|
||||
- **Group B in the protocol reference (D.6.9):**
|
||||
- interval size, the stop, and per-interval frequency, with Blastware's
|
||||
words (`N/A`, `>100` / `>200`, `<1.0`)
|
||||
- each interval's vector sum, with its OORANGE rule
|
||||
- #50's fixed-512 formula is retracted in place
|
||||
- CLAUDE.md and the README roadmap follow
|
||||
- Docs only.
|
||||
- **Group A in the protocol reference, and the three meanings of mic
|
||||
"units".**
|
||||
- **D.6.8:** the identity block, the trigger-source bitmask and the trigger
|
||||
settings.
|
||||
- **D.6.6:** recorded data vs report units vs unit peaks, with the
|
||||
MiniMate Plus and Blastware manual sections. CLAUDE.md carries the same
|
||||
glossary.
|
||||
- 🔶 Inferred: the histogram "terminal tail" `9c 06 00 42` is `9c 06 00`
|
||||
plus the serial's `B`.
|
||||
- Docs only: no code change, no migration.
|
||||
- **Where file-only decoding stands, and that prod's ASCII overlay is
|
||||
scaffolding.**
|
||||
- **CLAUDE.md "Where things stand"** now says plainly that a paired
|
||||
@@ -155,6 +459,46 @@ All notable changes to seismo-relay are documented here.
|
||||
- **CLAUDE.md "Where things stand"** now reflects the range fix.
|
||||
- Docs only: no code change, no migration.
|
||||
|
||||
### Migration
|
||||
|
||||
⚠ **Schema migration and backfill.** Rehearsed twice on a copy of prod's
|
||||
2026-09-30 snapshot (15,432 events), before and after the parity merge, with
|
||||
identical results.
|
||||
|
||||
**Before you start:**
|
||||
- `TOOL_VERSION` is bumped to **0.34.0**, which gates the regeneration, so no
|
||||
`--force` is needed.
|
||||
- **Back up `seismo_relay.db` first.**
|
||||
|
||||
**Then:**
|
||||
1. **Deploy.** On first start SFM migrates the database by itself.
|
||||
- The events table is re-keyed `UNIQUE(serial, timestamp, record_type)`
|
||||
(Migration 3): every row and id is kept and the indexes are rebuilt.
|
||||
Rehearsal: 0.27 s, every row identical, integrity ok.
|
||||
- `device_commands` is created.
|
||||
2. **In the `sfm` container, `python scripts/backfill_sidecars.py`** re-decodes
|
||||
every event file. ⚠ **Plan an overnight run:** the store holds about 64,000
|
||||
events after the 2200-day watcher forward, at about 1.5 files/s on the NAS,
|
||||
so roughly 12 hours.
|
||||
- **Every Series-3 histogram's time moves forward one second, in place**,
|
||||
with id and review state kept. Rehearsal: 9,852 moved, 0 refused, no id
|
||||
lost.
|
||||
- **The same-second waveform/histogram pairs coexist** (209 in the
|
||||
snapshot).
|
||||
- It also creates a row for any store file that never had one (341 in the
|
||||
snapshot): the known one-time behaviour, not duplicates.
|
||||
- **Report-less events** pick up every new field. **Report-paired events**
|
||||
keep the report's overlaid peaks, notes, sample rate and record time.
|
||||
3. **`python scripts/backfill_event_shape.py --db-path bridges/captures/seismo_relay.db
|
||||
--store-root bridges/captures/waveforms`** recomputes shape and offset
|
||||
metrics. Rehearsal: exit 0, `cleared_stale` 0.
|
||||
|
||||
**Terra-View** needs no change: it pairs twins by peak values and reads rows by
|
||||
id. Moving a histogram forward one second can carry an event across a
|
||||
deployment-window edge.
|
||||
|
||||
**Series-4** event times do not move.
|
||||
|
||||
## v0.33.0 — 2026-11-01
|
||||
|
||||
**SFM reads Series-3 events from the file alone, and proves it against
|
||||
|
||||
@@ -2,7 +2,7 @@
|
||||
|
||||
Ground-up Python replacement for **Blastware**, Instantel's Windows-only software for
|
||||
managing MiniMate Plus seismographs. Connects over direct RS-232 or cellular modem
|
||||
(Sierra Wireless RV50 / RV55). Current version: **v0.33.0**.
|
||||
(Sierra Wireless RV50 / RV55). Current version: **v0.34.0**.
|
||||
|
||||
Stack-level context — which repo owns what, and how the three project versions
|
||||
pair — lives in `../terra-view/docs/tmi-stack.md`, which is also loaded as
|
||||
@@ -45,13 +45,40 @@ Read this first when picking the project back up.
|
||||
- **Byte layouts** of every field read from the file:
|
||||
`docs/instantel_protocol_reference.md` Appendix **D.6**.
|
||||
|
||||
**Where the decoder stands on `dev`** (2026-11-03, run `20261103-121047`):
|
||||
**18 of 88 fields match on every event**, up from about 6 before v0.33.0.
|
||||
The four `dev` fixes below share one release and one backfill.
|
||||
**Where the decoder stands on `dev`** (2026-11-03, run `20261103-213557`):
|
||||
**47 of 88 fields match on every event**, up from about 6 before v0.33.0.
|
||||
Everything below on `dev` shares one release and one backfill. Groups A, B
|
||||
and C are done, which also fixed #50 and #51.
|
||||
- 🔑 **Events are keyed unit + time + type:** `UNIQUE(serial, timestamp,
|
||||
record_type)` (#51, Migration 3 in `sfm/database.py`, `dev`).
|
||||
- A waveform and its histogram may share a second: 209 times in prod's
|
||||
2026-09-30 store.
|
||||
- Any lookup "by event" must include the type.
|
||||
- An untyped event still dedups against an untyped row.
|
||||
- Rehearsed on a copy of the prod snapshot: rows and ids kept, 9,852
|
||||
histograms moved +1 s in place.
|
||||
- ✅ **Match on every event:**
|
||||
- sample rate, record time, pre-trigger, notes and event type (v0.33.0)
|
||||
- geophone range, job number, event times (6,524 / 6,524) and histogram
|
||||
start dates (63,518 / 63,518) — `dev`
|
||||
- group A (`dev`, reference D.6.8): serial, version, calibration, battery,
|
||||
trigger source, geo and mic trigger levels, stop mode, mic type
|
||||
- group B (`dev`, D.6.9): interval frequencies, vector sums, size, stop
|
||||
- group C (`dev`, D.6.10): histogram start and stop from the histogram's
|
||||
own event record, interval times, and the peak dates and times
|
||||
- 🔑 **"Units" means three different things — keep them apart** (reference
|
||||
D.6.6):
|
||||
- **Recorded data:** the mic samples and interval peaks in the file, as
|
||||
raw counts with no unit.
|
||||
- **Report units:** dB(L) or psi(L) in a report.
|
||||
- A Blastware report uses that PC's Blastware preference at the moment
|
||||
it wrote the report; carve-out `units-is-a-display-preference`.
|
||||
- SFM's report uses SFM's own fixed choice.
|
||||
- **Unit peaks:** the unit's own summary, in its keypad Microphone Units
|
||||
setting. Shown on its screen, in Blastware's event list, and in the 0C
|
||||
record.
|
||||
- Where the unit stores that setting is not measured yet; a keypad test
|
||||
on a bench unit would show it.
|
||||
- ✅ **Geophone samples** are exact on **6,524 / 6,524** waveforms in every
|
||||
year (`dev`; v0.33.0 had 6,491, its 33 others being Sensitive-range events
|
||||
read 8× high).
|
||||
@@ -65,18 +92,14 @@ Read this first when picking the project back up.
|
||||
- ✅ **Histogram PVS** = the stored per-interval PVS²: 69,989 / 70,042.
|
||||
**Mic:** one count = 0.25 Pa, dB offset 81.9384; a few dozen stragglers.
|
||||
- ❌ **Open:**
|
||||
- histogram start times are 1 s early (#51; fixing it moves every stored
|
||||
histogram by 1 s, and the event key is (serial, time), so it needs a
|
||||
decision first)
|
||||
- the mic stragglers: ~20 one-minute histograms with an interval or two off
|
||||
- Blastware prints `OORANGE` when the vector sum alone exceeds the range
|
||||
(a carve-out to prove)
|
||||
- ⬜ **Not read yet, in the order proposed** (2026-11-03):
|
||||
- **A. Setup fields:** trigger source and levels, stop mode, mic type,
|
||||
display units, firmware version, serial number, calibration, battery.
|
||||
- **B. Histogram interval detail:** per-interval frequencies (#50: they
|
||||
assume 1024 sps), per-interval PVS, interval size, stop time.
|
||||
- **C. #51 timing:** start time, per-interval times, peak times.
|
||||
- ~~**A. Setup fields**~~ ✅ done on `dev`.
|
||||
- ~~**B. Histogram interval detail**~~ ✅ done on `dev`. Frequencies (#50),
|
||||
per-interval PVS, interval size, stop.
|
||||
- ~~**C. #51 timing**~~ ✅ done on `dev`.
|
||||
- **D. Blastware's waveform calculations:** ZC frequency, acceleration,
|
||||
displacement, time of peak.
|
||||
- **E. Sensor check results.**
|
||||
@@ -285,6 +308,28 @@ Read this first when picking the project back up.
|
||||
menu. ⚠ **Neither series takes a call-home change while monitoring:** a MiniMate
|
||||
returns its device-info block, and a Micromate acks the write and ignores it.
|
||||
SFM refuses both up front.
|
||||
**Phase 5 built 2026-11-03, benched 2026-11-04:** change a unit's settings by serial,
|
||||
both series (`POST /device/settings/change`; the Config tab's Preview, then Send).
|
||||
Spec `docs/superpowers/specs/2026-11-03-sfm-phase5-settings-design.md`.
|
||||
- 🔑 **A MiniMate's settings block IS Series IV's `0x1A` layout** (measured):
|
||||
the 1A read assembles to 2,090 bytes headed by N = 2090, and all 11
|
||||
Blastware compliance writes reproduce from the block before them. One codec
|
||||
serves both series: `micromate/setup_fields.py`.
|
||||
- Limits are the units' own, from Instantel's manuals (Brian). A live send
|
||||
needs its preview's revision; refused up front: monitoring, a Micromate on
|
||||
its factory setup or whose schedule would load another setup.
|
||||
- Retired: `/device/config` (410), `apply_config`, `_encode_compliance_config`.
|
||||
- **Benched 2026-11-04, both series:** every change acknowledged, read back,
|
||||
and confirmed on the unit's screen; both units restored byte for byte. The
|
||||
MiniMate alarm write is measured and now on.
|
||||
- ⚠ **A MiniMate's open setup menu wins:** a change sent while it is open is
|
||||
lost when the operator presses Cancel or Save (the menu writes its whole-block
|
||||
copy back). The preview warns; nobody in the menus while the office sends.
|
||||
- ⚠ An escaped checksum byte leaves a stray `0x10` in a Series-3 reply's data
|
||||
(about 1 frame in 85). The settings and waveform reads take exactly what they
|
||||
asked for; other reads are unaudited for it.
|
||||
- ⚠ The Micromate scheduler switch is not in any block SFM reads, so a leftover
|
||||
schedule blocks a change even with the scheduler Off.
|
||||
**Ring path measured the same night:** with THOR's watchdog off, a call-home
|
||||
reaches THOR when nobody holds the line, and **is lost when SFM holds it** --
|
||||
the unit takes SFM's connection for the call, times out and does not retry.
|
||||
|
||||
@@ -1,4 +1,4 @@
|
||||
# seismo-relay `v0.33.0`
|
||||
# seismo-relay `v0.34.0`
|
||||
|
||||
A ground-up replacement for **Blastware** — Instantel's aging Windows-only
|
||||
software for managing seismographs. Supports both the **MiniMate Plus
|
||||
@@ -95,6 +95,25 @@ over direct RS-232 or cellular modem (Sierra Wireless RV50 / RV55).
|
||||
>
|
||||
> ⚠ The deploy owes a backfill; it does not move event times. See the
|
||||
> changelog's *Migration*.
|
||||
>
|
||||
> **v0.34.0 (2026-11-04)** reaches Series-4 parity and reads most of
|
||||
> Blastware's report from the event file alone.
|
||||
> - **Series-4 parity:** one device door by serial for both series, with
|
||||
> reads, downloads, start/stop, call-home and settings changes, each audited
|
||||
> and read back. MiniMate request framing is fixed (#46).
|
||||
> - **The file-only decode:** 47 of Blastware's 88 report fields match on
|
||||
> every DL2 event, and 8 more on all but one or two.
|
||||
> - Sensitive-range events are no longer 8× high.
|
||||
> - Histograms decode correctly and carry Blastware's own times (#51).
|
||||
> - Interval frequencies follow the sample rate (#50).
|
||||
> - New from the file: the job number, serial, version, calibration,
|
||||
> battery, trigger source and levels, interval detail, peak times and
|
||||
> peak acceleration.
|
||||
> - **Events are identified by unit + time + type.**
|
||||
>
|
||||
> ⚠ The deploy migrates the events table and owes an overnight backfill that
|
||||
> moves every Series-3 histogram time by one second. See the changelog's
|
||||
> *Migration*.
|
||||
> See [CHANGELOG.md](CHANGELOG.md) for full version history.
|
||||
|
||||
---
|
||||
@@ -647,18 +666,19 @@ Implementation steps (concrete):
|
||||
3. flip ingest so reports are kept only for checking (retire the overlay)
|
||||
4. stop the watchers forwarding reports
|
||||
|
||||
**Done so far: 18 of 88 report fields match on every DL2 event.**
|
||||
**Done so far: 47 of 88 report fields match on every DL2 event.**
|
||||
- In v0.33.0: setup fields, notes, event type, histogram PVS, mic.
|
||||
- On `dev`:
|
||||
- the geophone range
|
||||
- the job number
|
||||
- histograms that decoded wrongly
|
||||
- the footer: no more day-late histograms; every waveform time exact
|
||||
- serial, version, calibration, battery, trigger source and levels, stop mode, mic type
|
||||
- histogram interval detail: frequencies (#50 fixed), per-interval PVS, interval size, stop
|
||||
- histogram start, stop, interval and peak times (#51 fixed); events keyed unit + time + type
|
||||
- A Blastware report's dB/psi is its PC's preference, not anything in the event file: a carve-out.
|
||||
|
||||
**Next:**
|
||||
- setup fields still unread: trigger, stop mode, units, serial, calibration, battery
|
||||
- histogram interval detail: frequencies (#50), per-interval PVS, interval size, stop time
|
||||
- histogram start times (#51)
|
||||
- the values Blastware computes itself: ZC frequency, acceleration, displacement, time of peak
|
||||
- the sensor check results
|
||||
- the monitor log
|
||||
|
||||
@@ -11,6 +11,11 @@
|
||||
|
||||
| Date | Section | Change |
|
||||
|---|---|---|
|
||||
| 2026-11-04 | SUB 1A / 09 reads, SUB 68–74 settings write, the keypad | **SFM's settings write, benched on BE9441 (Brian at the unit; ~12 writes, each with his go).** **Every write** -- trigger 0.04 ↔ 0.05, a note, several fields at once (Project, job number + its report flag, trigger), the alarm 1.0 ↔ 1.5, and a full restore -- was acknowledged on all nine steps (`97 8C 8E×5 8D 7D 7C 96 8B 8D`), read back as sent, and **confirmed on the unit's own screen**; the unit ended byte for byte as found. Moved bytes were exactly the field's: trigger f32 at each geophone channel +30 (`+31..+33` moved), **alarm f32 at channel +38** (`+39` moved; the first Series-3 alarm write), job number `[40:42]`, its report bit `[39]` `0x02`, a note's value window. **`[26:28]`** went `01 7f` → `00 00` on SFM's first write (Blastware's value) and the unit **set `01 7f` again during the next monitoring session**. The **two bytes after the block** went out as `00 00` (Blastware sends a per-unit constant) and were taken. **🔑 Escaped-checksum artifact:** when a reply's checksum byte is itself escaped (02 / 03 / 04, ~1 frame in 85), `S3FrameParser` keeps the escape's `0x10` and strips only the byte after it, so the frame's data gains one trailing `0x10`. It hit the first live 1A read (frame B 1,026 bytes after the header); the 12 recorded reads never had. SFM's settings read and waveform read now take exactly the length they asked for. **🔑 The keypad menu wins:** a write sent while the setup menu was open was acknowledged and read back, then **lost when the operator pressed Cancel or Save** -- the menu writes its own copy of the **whole** block back (both times the block returned byte for byte to its state when the menu was opened). A keypad Cancel with nothing pending leaves the block unchanged. **While monitoring**, the 1A read returns the device-info block (SFM refuses, nothing sent), and the opening poll was answered only intermittently (2 of 3 attempts timed out). Code: `minimateplus.protocol.read_compliance_content` / `read_waveform_data_raw`, `micromate.setup_fields`; notes `~/bench-logs/2026-11-04-sfm-settings/`. |
|
||||
| 2026-11-03 (5) | SUB 1A / 71 / 69 (settings read and write) | **The settings block, read and written as content (measured, BE9441's 10-26 recording and BE11529's 2026-04-20 captures).** **Read:** unescape each 1A data frame and take `data[11:]`; every frame but the last starts with one `00` that is not content; dropped, the frames join into **2,090 bytes headed by N = 2090: Series IV's `0x1A` content layout** (12 / 12 reads, Blastware's 4 × 512 + 42 and SFM's 1024 + 1024 + 42). The old "stable anchor" `be 80 00 00 00 00` is content `[12:18]` (pre-trigger −0.25 + stop mode Fixed). **Round trip:** the read after each of Blastware's two 10-26 writes equals the image it had just written, all 2,090 bytes (2 / 2). While monitoring, the read returns the device-info block (`0e 'BE9441' …`, 5 / 5). **`[26:28]`:** Blastware writes `00 00` on all 11 writes; the unit reads `01 7f` after a monitoring session (BE9441 10-26, BE11529 4-20 15:19) and sets it by itself; meaning unknown. **The two bytes after the block** (`[2090:2092]` of the 0x71 image) are Blastware's own per-unit constant -- `7c ea` on all nine of BE11529's writes, `0c e9` on both of BE9441's -- not the block's CRC-16/AUG, and in no reply of BE9441's three-hour session; SFM sends `00 00`. **`0x09` `[200:202]`:** Blastware echoed the unit's `8c 76` on all nine April writes; on 10-26 it read `17 17` and wrote `78 76` (read back so); meaning unknown. **Blastware re-renders the mic trigger level:** on BE11529's first write (4-20 15:19) the unit read 0.005 and 0.01 psi in its two `MicL` channel blocks (3 and 7; Series 3 carries 8 channel blocks of 48 bytes from `[1708]`, the second four prefixed `0x32`) and Blastware wrote 0.004983 and 0.010058 -- the same levels to its 0.1 dB; every other write left them alone. **Every one of the 11 Blastware writes reproduces** from the block before it with only the fields Blastware changed (plus that re-render and, on 10-26, the mic bit of `[25]`). Code: `minimateplus.protocol.assemble_compliance_content`, `read_compliance_content`, `micromate.setup_fields`; tests `tests/test_s3_settings_read.py`, `tests/test_setup_fields.py`. |
|
||||
| 2026-11-03 (4) | Appendix D.6.10 (NEW), D.6.11 | ✅ **Histogram timing from its own event record (#51).** `00 28 05 00` `04 00` `fe f5` [start][stop]: Blastware's Histogram Start and Stop on 63,490 / 63,490 each; exactly one per histogram, start 0–1 s after the footer's ts1. Interval time = its end (start + (i + 1) × interval, capped at the stop), 2,308,524 / 2,308,524 rows; a peak's date/time = its interval's. Retracted: "histograms stay on ts1" (it held only while SFM's events were unique on serial + time; now unit + time + type). 47 of 88 report fields match on every DL2 event. |
|
||||
| 2026-11-03 (3) | Appendix D.6.9 (NEW), D.6.10 | ✅ **Histogram interval detail.** Interval size = uint16 seconds at `k − 40`; stop = footer ts2. Frequency = (sample rate / 2) / half-period, 527,915 / 527,915 cells at 1024 sps and 1,725 / 1,725 at 2048 — **#50 retracted** (a fixed 512 halved 2048-sps frequencies). Blastware's words: `N/A` (half-period 0), `>100` / `>200` (≤ 5 samples), `<1.0`. Per-interval vector sum √PVS²: 63,497 histograms; `OORANGE` when over range with a clamped channel, 17 / 17. 34 of 88 report fields now match on every DL2 event. |
|
||||
| 2026-11-03 (2) | Appendix D.6.6, D.6.8 (NEW), D.6.9 | ✅ **Identity, battery and trigger, from the file.** **D.6.8:** the identity block before the setup name is SUB FE's (serial `k − 202`, firmware `k − 147`, DSP `k − 138`, calibration `k − 132` + by `k − 128`, model `k − 72`; battery uint16 /100 at `k − 190`); all 70,042 / 70,042. The embedded event record's two unknown bytes are the **trigger source** bitmask (6,524 / 6,524). Trigger sources `k − 19`, stop mode `k − 31`, per-channel trigger level float32 at label + 30, mic type at MicL + 4 (Series IV's code). **D.6.6:** recorded data vs report units vs unit peaks, with the manual sections; a Blastware report's dB/psi is the PC's preference. 🔶 `9c 06 00 42` (the histogram "terminal tail") looks like `9c 06 00` + the serial's `B`. 28 of 88 report fields now match on every DL2 event. |
|
||||
| 2026-11-03 | Appendix D.3.3, D.6.1, D.6.3, D.6.5, D.6.7, §8 | ✅ **File-only decode, second pass (on `dev`).** **D.3.3:** the footer is the file's last 26 bytes (70,041 / 70,041); an earlier stop-time record fooled the first-match search on 14 files, making histograms a day late. Its `[18:24]` is **not** fixed (retracted). **D.6.1:** STRT[18] now picks the codec; the waveform codec had claimed 2018 5 s histograms. **D.6.3:** the job number (flags `k − 9` bit `0x02`, uint16 at `k − 8`; 2,997 / 2,997). **D.6.5:** the PVS² high word is non-zero above 1.28 in/s (retracted "reads 0000"), so the layout check now uses peak ≤ PVS ≤ √3·peak (34,502,955 / 34,502,955); Blastware's "Number of Intervals" is the monitoring time ÷ the interval. **§8:** where the 1995 default-clock events come from. 18 of 88 report fields now match on every DL2 event. |
|
||||
| 2026-11-03 | call home (SUB 2C / 7E / 7F) | **SFM's call-home write, measured both ways.** SFM's 0x7E image (`write_image` of the 0x2C read with byte 5 set, framed ONCE) and its 0x7F confirm reproduce Blastware's 2026-04-20 enable and disable writes byte for byte (BE11529; `tests/test_s3_call_home_bw_frames.py`). Live on BE9441, idle: a no-op, on and off were all acked (0x81 / 0x80) and read back, and the unit's menu agreed. Only byte 5 changes: no unit-maintained field, unlike Series 4's `[118:120]`. Byte 5 is read from the UNESCAPED block. ⚠ Unescaping is not idempotent, so a built image must never pass through `write_image` again: a call-in time of 16:02-16:04 is `10 02`-`10 04` in the image. ⚠ **While monitoring, the unit answers the 0x2C read with its DEVICE-INFO block** ('Instantel', 'MiniMate Plus', its serial), as it answers 1A. Idle again, minutes later, it returns the call-home block. So a monitoring unit's call-home cannot be read-modify-written; SFM refuses with 'stop monitoring first'. A blind write while monitoring stays untested on purpose. |
|
||||
| 2026-11-02 | Appendix D.3.1, D.6 (NEW), §15 | ✅ **Event fields SFM reads from the file alone (v0.33.0, plus the range on `dev`).** New D.6 records the bytes and the DL2 verification for each field: the record type `STRT[18]`, the recording-setup block (sample rate, pre-trigger, record time, the four notes), the geophone range (label + 29 in the setup's channel blocks), each histogram interval's PVS², and the mic scale (one count = 0.25 Pa). **Retracted in place:** D.3.1's `STRT[20]` = record time (it is `00` on every DL2 file; the "70 s" SFM used to report was `STRT[18]`, the record-type byte), and the 2026-08-26 reading of sub-minute histogram records as little-endian (big-endian from byte 5 since v0.32.0, #47/#49). **For #48:** the file's copy of the block puts the pre-trigger where the 1A "stable anchor" `be 80 00 00 00 00` sits. In the file, though, it is each event's own pre-trigger, which varies on the same unit on the same day (253–256 samples at 1024 sps), and Blastware reports it per event. So the file says little about whether the live 1A loses its anchor, and #48 stays open. |
|
||||
@@ -3799,28 +3804,156 @@ Each interval stores its peak vector sum **squared**:
|
||||
- **Verified:** interval psi mismatches fell from 42,783 to 26, and mic peak mismatches from 345
|
||||
to 40.
|
||||
|
||||
#### D.6.7 Not read from the file yet
|
||||
**Three things share the word "units". Keep them apart** (2026-11-03):
|
||||
|
||||
*Updated 2026-11-03. 18 of 88 report fields now match on every DL2 event.*
|
||||
| Name | What it is | Its units are set by | Where it shows |
|
||||
|---|---|---|---|
|
||||
| **Recorded data** | the mic samples and interval peaks in the event file | nothing: they are raw counts | the event file |
|
||||
| **Report units** | dB(L) or psi(L) in a report | Blastware's report: the PC's preference (Blastware manual 714U0301 Rev 22 §4, Preferences → Units and Channel). SFM's report: SFM's own fixed choice (PDF PSPL in dB(L), plot in psi) | a Blastware report, an SFM report |
|
||||
| **Unit peaks** | the peaks the unit works out for its own summary | the unit's Microphone Units setting: psi(L), dB(L) or Pa(L), on the keypad (Right Arrow + Setups) or from Compliance Setup → Special Setups (MiniMate Plus manual 716U0101 Rev 15 §3.9.7) | the unit's screen, Blastware's event list, the 0C record on a live download |
|
||||
|
||||
- A Blastware report converts the recorded counts in its PC's preference. That is why DL2's
|
||||
reports flip dB ↔ psi fleet-wide, in 61 clean runs by report-write time. The decode checker's
|
||||
`units-is-a-display-preference` carve-out covers it.
|
||||
- 🔶 **Where the unit stores its own setting, and its unit peaks, is not measured.** Blastware's
|
||||
event list must read the unit peaks from somewhere, so they are probably in the event file,
|
||||
perhaps near the embedded event record.
|
||||
- **To settle it (proposed, not done):** on a bench unit, change Microphone Units on the keypad,
|
||||
then diff a read-only `1A` read and a short recorded event.
|
||||
|
||||
#### D.6.8 Identity, battery and trigger ✅ 2026-11-03
|
||||
|
||||
**The identity block** sits before the setup name. It is what the live read gets from SUB FE
|
||||
(`DeviceInfo`); offsets are from `k`:
|
||||
|
||||
| Offset | Content | DL2 |
|
||||
|---|---|---|
|
||||
| `k − 202` | serial number, NUL-terminated | 70,042 / 70,042 |
|
||||
| `k − 193` | firmware minor (`0x11` = 17), as SUB EA | — |
|
||||
| `k − 190` | battery, uint16 BE, hundredths of a volt | 70,042 / 70,042 (Blastware rounds half up: 6.25 → "6.3 Volts") |
|
||||
| `k − 147` | firmware, `"S338.17"` | |
|
||||
| `k − 138` | DSP version, `"10.72"` | Version 70,042 / 70,042 as `V {DSP}-{firmware after "S33"} {model}`; only `10.72-8.17` occurs, so the rule is proven for that alone |
|
||||
| `k − 132` | calibration date, `dd mm yyyy` (BE year) | Calibration 70,042 / 70,042 as `{Month} {d}, {yyyy} by {k − 128}` |
|
||||
| `k − 128` | calibrated by, `"Instantel"` | |
|
||||
| `k − 94` | manufacturer, `"Instantel"` | |
|
||||
| `k − 72` | model, `"MiniMate Plus"` / `"BlastMate III"` | |
|
||||
|
||||
- `k − 180 … k − 149` hold eight float32s (1.0, 8.0, then 1.0s). Not identified.
|
||||
- 🔶 **Inferred, not measured:** the three bytes before the serial are `9c 06 00`. With the
|
||||
serial's `B` (0x42) that makes `9c 06 00 42`, the histogram codec's "terminal tail". It looks
|
||||
like the start of this record rather than the end of a block. Every serial starts with B
|
||||
(BE… / BA…).
|
||||
|
||||
**The trigger source** is in the embedded event record (§7.8.9). The two bytes between its lead
|
||||
`00 28 05 00` and `fe 80`, a uint16 BE bitmask, were "unknown" until now:
|
||||
|
||||
| Value | Blastware's Trigger |
|
||||
|---|---|
|
||||
| `0x0001` | Tran |
|
||||
| `0x0002` | Vert |
|
||||
| `0x0004` | Long |
|
||||
| `0x0008` | MicL |
|
||||
| `0x0200` | Manual |
|
||||
|
||||
That holds on 6,524 / 6,524 waveforms.
|
||||
|
||||
**Trigger settings,** in Series IV's `0x1A` layout:
|
||||
|
||||
| Offset | Content | DL2 |
|
||||
|---|---|---|
|
||||
| `k − 19` | trigger sources: `0x07` geophones, `0x08` mic (`0x80` seen once, not identified) | — |
|
||||
| `k − 23` | active sensors, `0x0f` (all four) | 69,975, `0x07` on 8 mic-less files |
|
||||
| `k − 31` | stop mode: 0 = Fixed | 6,524 / 6,524, the only value in DL2 |
|
||||
| channel label + 30 | float32 trigger level: geophones in/s, mic psi | geo 6,484 / 6,484, mic 4,412 / 4,412 |
|
||||
| MicL + 4 | mic type code: 2 = Linear Weighting, as Series IV | 70,034 / 70,034, the only value |
|
||||
|
||||
- **Blastware prints a trigger level only when its channel is a trigger source** and the event
|
||||
was not Manual.
|
||||
- **For the mic level in dB, Blastware converts with 6895 Pa per psi.** That gives 4,272 / 4,272;
|
||||
the exact 6894.757 gives 4,271, failing one boundary case (0.01 psi → "130.8 dB(L)").
|
||||
- **The file's channel block is the 1A's, 4 bytes earlier.** Compare the 1A's scale constant at
|
||||
+28 and range at +33 with the file's +24 and +29.
|
||||
|
||||
#### D.6.9 Histogram interval detail ✅ 2026-11-03
|
||||
|
||||
**Interval size** is a uint16 count of seconds at `k − 40` (Series IV `[8:10]`): 2, 5, 15, 60 or
|
||||
300. It matches Blastware's IntervalSize ("1 minute", "5 seconds", …) on 63,518 / 63,518 DL2
|
||||
histograms. **The stop** is the footer's ts2: 63,460 / 63,518. The other 58 are Blastware a
|
||||
second earlier, the #51 family.
|
||||
|
||||
**Each interval's frequency** comes from its half-period in samples:
|
||||
`frequency = (sample rate / 2) / half-period`. That matches 527,915 / 527,915 printed cells at
|
||||
1024 sps and 1,725 / 1,725 at 2048.
|
||||
- ⚠ **RETRACTED (#50):** "frequency = 512 / half-period". 512 is half the sample rate at
|
||||
1024 sps only; at 2048 sps it halved every frequency.
|
||||
|
||||
Blastware prints these words instead of a number, on ~3.1 M DL2 cells:
|
||||
|
||||
| half-period / frequency | printed |
|
||||
|---|---|
|
||||
| half-period 0 | `N/A` |
|
||||
| half-period ≤ 5 samples | `>100` at 1024 sps, `>200` at 2048 |
|
||||
| below 1 Hz | `<1.0` |
|
||||
| below 10 Hz (20 at 2048) | one decimal |
|
||||
| otherwise | a whole number |
|
||||
|
||||
All four channels match every DL2 histogram.
|
||||
|
||||
**Each interval's vector sum** is √PVS² (D.6.5) at the event's range: 63,497 histograms match.
|
||||
- Blastware prints `OORANGE` for an interval's vector sum above the range when it also clamped
|
||||
a channel in that interval: 17 / 17 cells. The decode checker's saturation carve-out covers
|
||||
it.
|
||||
- 4 cells sit about 4e-6 past a rounding boundary. Blastware's arithmetic is a hair lower; they
|
||||
stay counted as mismatches.
|
||||
|
||||
#### D.6.10 Histogram timing — the histogram's own event record ✅ 2026-11-03 (#51)
|
||||
|
||||
**A histogram carries an embedded event record like a waveform's** (§7.8.9):
|
||||
|
||||
00 28 05 00 04 00 fe f5 [start 8 B] [stop 8 B]
|
||||
lead source marker dd mm yyyy 00 hh mm ss (as the footer)
|
||||
|
||||
- **Source `04 00`** sits where a waveform's trigger-source bitmask goes (D.6.8).
|
||||
- **The start is Blastware's Histogram Start Time** on 63,490 / 63,490 DL2 histograms, and the
|
||||
stop is its Stop Time on 63,490 / 63,490.
|
||||
- On all 63,500 there is exactly one such record. Its start is 0 or 1 s after the footer's ts1
|
||||
(1 s on 61,645), and its stop 0 or 1 s before the footer's ts2 (1 s on 57).
|
||||
- That makes the footer's start a second early on 97%. #51 had read it as SFM's error; it is
|
||||
the footer's own convention.
|
||||
|
||||
**What follows from the start:**
|
||||
|
||||
| Field | Blastware's rule | DL2 sample |
|
||||
|---|---|---|
|
||||
| Each interval's printed time | its end: start + (i + 1) × interval, capped at the stop | 2,308,524 / 2,308,524 rows |
|
||||
| Each peak's date and time (Tran, Vert, Long, vector sum, mic) | those of the interval holding its first maximum | 2,000 / 2,000 each |
|
||||
|
||||
> ⚠ **RETRACTED 2026-11-03:** "histograms stay on ts1". That held only while SFM's events
|
||||
> table was unique on (serial, timestamp). A waveform and its histogram share a second in
|
||||
> Blastware's timing (209 times in prod's 2026-09-30 store). SFM's events are now keyed on
|
||||
> unit + time + type.
|
||||
|
||||
#### D.6.11 Not read from the file yet
|
||||
|
||||
*Updated 2026-11-03. 47 of 88 report fields now match on every DL2 event.*
|
||||
- **Fields not read yet:**
|
||||
- trigger source and levels, stop mode, mic type, display units, firmware version, serial
|
||||
number, calibration, battery
|
||||
- per-interval frequencies (#50: they assume 1024 sps), per-interval PVS, interval size,
|
||||
histogram stop time
|
||||
- extended notes
|
||||
- the values Blastware computes: ZC frequency, acceleration, displacement, time of peak
|
||||
- sensor check results
|
||||
- monitor log
|
||||
- **Open cases:**
|
||||
- histogram start times are 1 s early (#51)
|
||||
- about 20 one-minute histograms with a mic peak an interval or two off
|
||||
- Blastware prints `OORANGE` when the vector sum alone exceeds the range (a carve-out still to
|
||||
prove)
|
||||
- Blastware prints `OORANGE` when an event's vector sum alone exceeds the range, with no
|
||||
clamped channel (a carve-out still to prove; the interval version is proven, D.6.9)
|
||||
- **Resolved on `dev`, 2026-11-02 → 03:**
|
||||
- the 37 histograms that decoded wrongly (D.6.1, D.6.5)
|
||||
- the 26 histogram start dates a day off (D.3.3; 17 of them were the same 5 s files, timed
|
||||
as waveforms)
|
||||
- the job number (D.6.3)
|
||||
- identity, battery, trigger source and trigger settings (D.6.8); Units is Blastware's
|
||||
preference (D.6.6)
|
||||
- histogram interval detail: frequencies (#50), vector sums, interval size, stop (D.6.9)
|
||||
- histogram start, stop, interval and peak times (#51, D.6.10)
|
||||
|
||||
---
|
||||
|
||||
|
||||
@@ -1925,6 +1925,15 @@ at `payload[3:5]`:
|
||||
| 2nd | `0x0002` | 535 B | the file body |
|
||||
| 3rd | `0x0000` | 11 B | all zeros = **end of file** |
|
||||
|
||||
✅ **SFM reads the schedule this way, read-only (2026-11-03, phase 5)** --
|
||||
`MicromateProtocol.read_file` / `MicromateClient.read_schedule`, frames equal to
|
||||
THOR's byte for byte (`tests/test_micromate_schedule.py`). Two details the table
|
||||
above leaves out: the `0x94` request carries **`params[3] = 1`**, and the **first**
|
||||
`0x48` carries **`params[7] = 1`** (the later ones all-zero params); both `0x48`
|
||||
offsets are `0xFFFF`. A long file is **written** in 1,024-byte `0x8E` pieces
|
||||
(the five-entry *actioncheck* schedule went as 1,024 + 280). ⚠ Unmeasured: what
|
||||
`0x94` / `0x48` return for a unit with no schedule file.
|
||||
|
||||
⚠ This is the single most consequential find of the session, because it is not
|
||||
specific to the scheduler. **`callhome.MMB` is a file too**, and the call-home
|
||||
config is the last unsolved piece of the project. Reading it should be a
|
||||
@@ -2736,6 +2745,39 @@ were wrong.
|
||||
established** — only one setting was varied. Series III's offsets are a starting
|
||||
hypothesis, not a transfer.
|
||||
|
||||
#### Bench 2026-11-04: SFM's first setup push (UM20147)
|
||||
|
||||
SFM's audited `POST /device/settings/change`, one send per go (Brian at the
|
||||
unit). Notes: `~/bench-logs/2026-11-04-sfm-settings/`.
|
||||
|
||||
**Measured:**
|
||||
- **The setup push works as THOR's.** Trigger 0.6 → 0.5, then a five-field
|
||||
change (Location, Client, job number + its report flag, record time), then a
|
||||
full restore. Each send was THOR's seven frames, acknowledged in THOR's order
|
||||
(`25 97 8C 7D 7C 8E 8D`), read back as sent, and confirmed in the unit's menu.
|
||||
The setup block ended byte for byte as found, CRC included.
|
||||
- **The unit's recomputed CRC equals SFM's** (`with_crc`): after the first push
|
||||
the stored block equalled SFM's computed image byte for byte, CRC `ea8d`
|
||||
included.
|
||||
- **`schedule.dat` read on a real unit** (`0x94` → `0x6B`; `0x48` → descriptor
|
||||
`04 00 … 01 … 01`, body, all-zero end). UM20147 holds a leftover THOR
|
||||
schedule: repeat on, 07:00, start monitoring with
|
||||
`Fay - Commercial Street - Irish Center.mmb`. The unit runs `test2.MMB`, so
|
||||
SFM blocked the change, as designed.
|
||||
- 🔑 **The scheduler On/Off switch is in none of the blocks SFM reads.** With
|
||||
the keypad switch Off, then On (saved), these were byte for byte identical:
|
||||
`0x08` prefs, `0x2E`, `0x1A`, `0x2C`, `0x41` and `schedule.dat`. The
|
||||
firmware's `SysPref.bMonitorScheduler` lives elsewhere. THOR's end-of-push
|
||||
`0x47` pair (`params[7]` 1 then 3; replies `04 00 … 0N … 00 01`) was only
|
||||
ever captured with the switch On. **Next:** a THOR bridge recording with the
|
||||
switch Off (parked for the work-hours project).
|
||||
- **While monitoring**, a settings preview and a live attempt were both refused
|
||||
on the run state before any block was read (409, nothing sent, 0 write frames).
|
||||
- **With call-home off, a stop goes straight to idle** (`monitoring` →
|
||||
`idle`): no calling-home state and no ring.
|
||||
- Call-home `0x01` ↔ `0x00` was taken again, both ways. The plan's
|
||||
"unobserved" warning is retired for those values.
|
||||
|
||||
## What the THOR manual settles about the ACH session (2026-09-24)
|
||||
|
||||
Source: `manuals/723U0201 THOR Operator Manual Rev 08.pdf` §6.2, §3.6.
|
||||
|
||||
@@ -0,0 +1,525 @@
|
||||
# Phase 5: Changing a Unit's Settings by Serial — Implementation Plan
|
||||
|
||||
> **For agentic workers:** REQUIRED SUB-SKILL: Use superpowers:subagent-driven-development (recommended) or superpowers:executing-plans to implement this plan task-by-task. Steps use checkbox (`- [ ]`) syntax for tracking.
|
||||
|
||||
**Goal:** An operator edits a unit's live settings in SFM, by serial, on either series: preview old → new, send once (audited), and see what the unit now holds.
|
||||
|
||||
**Architecture:**
|
||||
- **One pure settings codec for both series** (`micromate/setup_fields.py`), on the measured shared 2,090-byte layout.
|
||||
- **Each series' adapter supplies reads, the plan and the send** to the existing `run_change` core, unchanged.
|
||||
- Its "state" is a read-back verdict: `as asked` / `unchanged` / `differs`.
|
||||
- Series 3 sends through `push_config_raw`; Series 4 through `plan_setup_push`.
|
||||
- Series 4 also reads the unit's schedule, read-only, to refuse a change that a scheduled start would undo.
|
||||
- **One audited route**, `POST /device/settings/change`. The legacy by-host write is retired.
|
||||
|
||||
**Tech Stack:** Python 3 (FastAPI, pytest), vanilla JS tested in Node (`tests/test_webapp_device_routing.py`).
|
||||
|
||||
**Spec:** `docs/superpowers/specs/2026-11-03-sfm-phase5-settings-design.md` (approved by Brian 2026-11-03). Parent spec: `docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md`.
|
||||
|
||||
## Global Constraints
|
||||
|
||||
- **Worktree and branch:** work in `~/seismo-relay-parity` on `feat/series4-sfm-parity`. Check `git branch --show-current` before every commit; never commit to `main`; push every commit.
|
||||
- **Python:** `/home/serversdown/seismo-relay/.venv/bin/python -m pytest …` from the worktree root.
|
||||
- **The suite has 16 known failures.**
|
||||
- Run the full suite once before Task 1 and save the failure list in the plan workspace as `baseline-failures.txt`.
|
||||
- Before every commit, run the suite, read the failure list, and confirm it equals the baseline.
|
||||
- Commit in a separate call, never chained to the test run.
|
||||
- **No live device traffic** in any task. The bench is after the final review, with Brian's explicit go per send.
|
||||
- Never port 8200.
|
||||
- Never write modem baud or modem type.
|
||||
- Never send `0xA2`.
|
||||
- **`CHANGELOG.md` is not touched** on this branch; it is written on `dev` at the merge.
|
||||
- **No inline JavaScript.** New page logic goes in `sfm/static/device_routing.js` (DOM-free, Node-tested); glue goes in `sfm/static/sfm_webapp.js`.
|
||||
- **`docs/instantel_protocol_reference.md` is CRLF.** Edit it only with the Edit tool. Keep its rows in date order.
|
||||
- **Off-limits (the checker session's files):** `minimateplus/event_file_io.py`, `histogram_codec.py`, `waveform_codec.py`, `bw_xml_report.py`, `decode_check*.py`.
|
||||
- **`TOOL_VERSION` is unchanged:** nothing here changes event decoding. Operational consequence: none; no migration, no backfill.
|
||||
- **Grade every protocol claim** in comments and docs as measured or inferred.
|
||||
- **Mutation checks:** after a mutate/restore, delete the module's `__pycache__/*.pyc` before the confirming run.
|
||||
|
||||
## Review Focus
|
||||
|
||||
1. **A Micromate with no schedule file, or a schedule read that fails.**
|
||||
- A body with no records means no conflict, and the change proceeds.
|
||||
- A read that raises refuses the change in plain words.
|
||||
- Owner: Task 4; tests `test_no_schedule_records_is_no_conflict` and `test_an_unreadable_schedule_refuses`.
|
||||
2. **A float that is stored as f32.** 0.3 reads back as 0.30000001192.
|
||||
- The verdict compares bytes with the image written, never floats, so it reads `as asked`.
|
||||
- Owner: Task 2; test `test_f32_values_read_back_as_asked`.
|
||||
3. **A stale or foreign revision** after a keypad edit, or a preview of another unit.
|
||||
- The send is refused with 409, nothing is sent, and no audit row is written.
|
||||
- Owner: Tasks 4 and 5; tests `test_s4_stale_revision_sends_nothing` and `test_s3_stale_revision_sends_nothing`.
|
||||
4. **Range and trigger changed in one request.** The trigger is checked against the **new** range.
|
||||
- Owner: Task 2; test `test_trigger_checked_against_the_new_range`.
|
||||
5. **Notes at the edges.**
|
||||
- `""` clears a note.
|
||||
- 41 bytes is accepted; 42 is refused; non-ASCII is refused.
|
||||
- Labels are never written.
|
||||
- Owner: Task 2; tests `test_note_edges` and `test_note_labels_are_never_written`.
|
||||
|
||||
---
|
||||
|
||||
## File Structure
|
||||
|
||||
| file | responsibility |
|
||||
|---|---|
|
||||
| `minimateplus/protocol.py` | **Series 3 assembly:** `assemble_compliance_content`, `is_compliance_content`, `MiniMateProtocol.read_compliance_content`. **Writes:** `push_config_raw`'s pre-check raises `ImageRefused`. |
|
||||
| `minimateplus/client.py` | **Added:** `read_compliance_content()` and `read_settings_blocks()`. **Deleted:** `apply_config`, `set_project_info`, `_encode_compliance_config`. |
|
||||
| `micromate/setup_block.py` | **Added:** `with_crc(content)`. |
|
||||
| `micromate/setup_fields.py` (new) | **The shared, pure settings codec:** field registry, `editable_fields`, `check_changes`, `encode_setup`, `field_values`, `settings_state`, `revision`. |
|
||||
| `micromate/schedule.py` (new) | **Pure:** `parse_schedule`, `ScheduleEntry`, `schedule_conflicts`. |
|
||||
| `micromate/protocol.py` | **Added:** `read_file(path)`, using `0x94` then `0x48` pages. |
|
||||
| `micromate/client.py` | **Added:** `read_schedule()`, `get_active_setup_raw()`, `get_prefs_content()`, `get_trigger_content()`, `get_setup_content()`. |
|
||||
| `micromate/opcodes.py` | `ENABLEABLE_WRITES` gains the setup-push SUBs. |
|
||||
| `sfm/device_access/errors.py` | **Added:** `SettingsChanged` and `ChangeRefused`, both 409. |
|
||||
| `sfm/device_access/change.py` | **Added:** `settings_change()`. |
|
||||
| `sfm/device_access/s4.py` | `s4_settings` moves onto the codec. **Added:** `s4_change_settings`. |
|
||||
| `sfm/device_access/s3.py` | `Series3Adapter.settings` moves onto the codec. **Added:** `Series3Adapter.change_settings`. |
|
||||
| `sfm/device_access/access.py` | **Added:** `DeviceAccess.change_settings`. |
|
||||
| `sfm/server.py` | **Added:** `POST /device/settings/change`. `/device/config` and `/device/config/project` return 410. |
|
||||
| `sfm/static/device_routing.js`, `sfm/static/sfm_webapp.js`, `sfm/sfm_webapp.html` | The edit form. |
|
||||
| `tests/device_access_fakes.py` | The fakes gain settings blocks, a schedule, and writes. |
|
||||
|
||||
---
|
||||
|
||||
### Task 1: Series 3 — assemble a settings read into the logical block
|
||||
|
||||
**Measured basis (spec, 2026-11-03):** unescape each `1A` data frame and take `data[11:]`. Every frame but the last starts with one non-content `00` byte; drop it. The result is 2,090 bytes with `N = 2090` at `[0:2]`.
|
||||
|
||||
**Files:**
|
||||
- Modify: `minimateplus/protocol.py`, near `read_compliance_config` (≈ line 913)
|
||||
- Modify: `minimateplus/client.py`
|
||||
- Modify: `docs/instantel_protocol_reference.md` (one dated row, 2026-11-03)
|
||||
- Test: `tests/test_s3_settings_read.py` (new)
|
||||
|
||||
**Interfaces:**
|
||||
- Produces:
|
||||
- `assemble_compliance_content(frames: list[bytes]) -> bytes`. `frames` is each data reply's `frame.data`, escapes kept, in order.
|
||||
- `is_compliance_content(block: bytes) -> bool`: `len == 2090` and `int.from_bytes(block[0:2], "big") == 2090`.
|
||||
- `COMPLIANCE_CONTENT_LEN = 2090`.
|
||||
- `MiniMateProtocol.read_compliance_content() -> bytes`:
|
||||
- sends the same probe and B/C/D requests as `read_compliance_config`;
|
||||
- a missing data frame raises `ProtocolError` (no `continue`);
|
||||
- returns the assembled bytes **without** judging them, so a monitoring unit's device-info answer comes back for the caller to recognise.
|
||||
- `MiniMateClient.read_compliance_content() -> bytes`.
|
||||
- `MiniMateClient.read_settings_blocks() -> dict` with keys `event_index`, `compliance`, `trigger` and `waveform`. Each value is the bytes its existing read returns:
|
||||
- `event_index`: `proto.read_event_index()`
|
||||
- `compliance`: `read_compliance_content()`
|
||||
- `trigger`: `proto.read_trigger_config()`
|
||||
- `waveform`: `proto.read_waveform_data_raw()`
|
||||
|
||||
- [ ] **Step 1: Write the failing tests** in `tests/test_s3_settings_read.py`. Use `tests/fixtures/minimate-bench-10-26-26-histogram` (`unit_replies.bin` parsed with `S3FrameParser`). Group the `0xE5` frames into reads: a frame with `len(data) == 11` starts each read. Take the write images from `tests/test_minimate_write_frames.py` (`WRITES[0:13]`, `WRITES[13:26]`; the `0x71` payloads `[16:]` joined).
|
||||
|
||||
```python
|
||||
def test_reads_assemble_to_2090_bytes(): # all 12 reads, both frame patterns (5 and 3 frames)
|
||||
assert all(len(assemble_compliance_content(r)) == 2090 for r in READS)
|
||||
|
||||
def test_a_read_after_a_blastware_write_equals_the_write():
|
||||
assert assemble_compliance_content(READS[1]) == IMAGES[0][:2090]
|
||||
assert assemble_compliance_content(READS[2]) == IMAGES[1][:2090]
|
||||
|
||||
def test_a_monitoring_units_answer_is_not_settings(): # READS[3:8] start 0e 'BE9441'
|
||||
assert [is_compliance_content(assemble_compliance_content(r)) for r in READS[3:8]] == [False] * 5
|
||||
assert all(is_compliance_content(assemble_compliance_content(r)) for r in READS[:3] + READS[8:])
|
||||
|
||||
def test_read_compliance_content_refuses_a_missing_frame():
|
||||
... # a fake transport that answers the probe and frame B, then times out: ProtocolError, nothing assembled
|
||||
```
|
||||
|
||||
- [ ] **Step 2: Run them.** `…pytest tests/test_s3_settings_read.py -q`. Expected: FAIL (ImportError: `assemble_compliance_content`).
|
||||
- [ ] **Step 3: Implement** the Produces block in `protocol.py` and `client.py`. Use `unescape_reply` from `minimateplus.framing`. The docstring cites the measurement and its fixture.
|
||||
- [ ] **Step 4: Run them.** Expected: PASS (4 passed).
|
||||
- [ ] **Step 5: Add a reference row** to `docs/instantel_protocol_reference.md` (Edit tool; CRLF), dated 2026-11-03, measured. Cover:
|
||||
- the assembly rule;
|
||||
- the round trip (2 of 2);
|
||||
- `[26:28]`: Blastware writes `00 00` (11 of 11), and the unit sets `01 7f` after monitoring;
|
||||
- the trailing two bytes: a per-unit Blastware constant (`7c ea` BE11529 ×9, `0c e9` BE9441 ×2), not the CRC, and never in a reply;
|
||||
- `0x09 [200:202]`: echoed 9 of 9 in April; changed on 10-26 (`17 17` → `78 76`).
|
||||
- [ ] **Step 6: Run the full suite** and compare the failure list with the baseline. **Then commit** (separate call): `feat(s3): assemble a settings read into the 2,090-byte block`.
|
||||
|
||||
---
|
||||
|
||||
### Task 2: The shared settings codec
|
||||
|
||||
**Files:**
|
||||
- Create: `micromate/setup_fields.py`
|
||||
- Modify: `micromate/setup_block.py`: add `with_crc(content: bytes) -> bytes`, which returns the content with `CRC-16/AUG-CCITT` over `[0:N-2]` written BE at `[N:N+2]`.
|
||||
- Test: `tests/test_setup_fields.py` (new)
|
||||
|
||||
**Interfaces:**
|
||||
- Consumes: Task 1's `assemble_compliance_content`, used in tests only. The codec itself imports nothing from `minimateplus` and nothing from `sfm`.
|
||||
- Produces (all pure). Each `content` is the 2,090-byte (Series 3) or 2,092-byte (Series 4) block.
|
||||
- `editable_fields(content: bytes, series: int) -> list[dict]`. Each dict has `field`, `label`, `kind` (`"number"`, `"choice"`, `"text"` or `"bool"`) and `value`, plus as relevant `unit`, `min`, `max`, `choices` (a list of `{value, label}`) and `maxlength`.
|
||||
- `field_values(content: bytes, series: int) -> dict[str, Any]`: the same fields, values only.
|
||||
- `check_changes(content: bytes, series: int, changes: dict) -> dict`: returns the normalised changes, or raises `SettingsValueError(ValueError)` with a plain sentence. It has two kinds of check: static (names, types, choices, limits) and content-dependent (unit strings, the trigger against the range).
|
||||
- `encode_setup(content: bytes, series: int, changes: dict) -> bytes`:
|
||||
- same length as `content`;
|
||||
- only the changed fields' bytes move;
|
||||
- bit fields are patched bit by bit;
|
||||
- Series 3 also sets `[26:28] = 00 00` (`S3_BLASTWARE_FIXED`);
|
||||
- Series 4 returns `with_crc(...)`.
|
||||
- `settings_state(before: bytes, written: bytes, now: bytes, *, series: int) -> str`. It compares `[0:2090]`:
|
||||
- `"as asked"` if `now` equals `written` (Series 4 also needs `crc_ok(now)`);
|
||||
- else `"unchanged"` if `now` equals `before`;
|
||||
- else `"differs"`.
|
||||
- `revision(blocks: list[bytes]) -> str` = `hashlib.sha256(b"".join(blocks)).hexdigest()[:16]`.
|
||||
- `S3_ALARM_WRITE_MEASURED = False`. While False, `geo_alarm_ips` is shown (read-only, `kind` plus `"readonly": True`) and refused in `check_changes`.
|
||||
|
||||
**The field registry** (content offsets; channel `k` = `1708 + 48·k`, `k` = 0, 1, 2 for the geophones):
|
||||
|
||||
| field | series | bytes | values (exact) |
|
||||
|---|---|---|---|
|
||||
| `record_mode` | 3 | `[5]` | `single_shot`=0, `continuous`=1, `histogram`=3, `histogram_continuous`=4 |
|
||||
| `record_mode` | 4 | `[5]` | `waveform`=1, `manual`=2, `histogram`=3, `combo`=4 |
|
||||
| `sample_rate` | 3, 4 | `[6:8]` u16 BE | {1024, 2048, 4096} |
|
||||
| `histogram_interval_s` | 3, 4 | `[8:10]` u16 BE | {2, 5, 15, 60, 300, 900} |
|
||||
| `record_time_s` | 3 | `[18:22]` f32 BE | 1.0 ≤ v ≤ `S3_MAX_RECORD_S[sample_rate]` = {1024: 104, 2048: 52, 4096: 26}, and ≤ 13 when `record_mode` is `histogram_continuous` (the **new** mode and rate if they change too) |
|
||||
| `record_time_s` | 4 | `[18:22]` f32 BE | 1.0 ≤ v ≤ 90.0 |
|
||||
| `geo_trigger_ips` | 3, 4 | ch k `+30` f32 BE, all three | 0.005 ≤ v ≤ 10.0, a multiple of 0.001 (within 1e-9), and ≤ the (new) range's full scale (10.0 / 1.25) |
|
||||
| `geo_range` | 3 | ch k `+29` u8, all three | `normal`=0, `sensitive`=1 |
|
||||
| `geo_alarm_ips` | 3 (gated) | ch k `+38` f32 BE, all three | 0.005 ≤ v ≤ full scale |
|
||||
| `job_number` | 3, 4 | `[40:42]` u16 BE | 1 ≤ v ≤ 9999 |
|
||||
| `job_number_shown` | 3, 4 | `[39]` bit `0x02` | bool |
|
||||
| `note_1` … `note_4` | 3, 4 | value `[144+64n : 186+64n]`; label `[122+64n : 144+64n]` read only | printable ASCII 0x20–0x7E, ≤ 41 bytes, zero-filled to 42 |
|
||||
|
||||
The limits are **the units' own, from Instantel's manuals** (Brian, 2026-11-03), cited in the module as comments:
|
||||
- **Trigger** 0.005–10 in/s, steps of 0.001: MiniMate Plus manual 716U0101 Rev 15, Appendix *Series III Specifications*; Micromate manual 721U0201 Rev 06, *Geophone Trigger Level*.
|
||||
- **Record time:**
|
||||
- Micromate 1–90 s (*Record Time*).
|
||||
- MiniMate: §4.4's *Maximum Record Times*, 1 MB unit, channels 1–4; §3.8.9, 13 s in Histogram Combo.
|
||||
- **Job number** 1–9999: both manuals.
|
||||
|
||||
**A level write is refused** unless all three geophone channels' unit string, `ch +34:+38` with NULs and `.` stripped, equals `in`. Measured: `in.` and `in` both occur on UM20147. A unit set to Metric is unmeasured.
|
||||
|
||||
- [ ] **Step 1: Write the failing tests** in `tests/test_setup_fields.py`:
|
||||
|
||||
```python
|
||||
def test_s3_reproduces_every_blastware_write():
|
||||
# BE11529's 9 April images (bridges/captures/4-20-26/**/raw_bw_*.bin), in time order (the HHMMSS in
|
||||
# the name): before = the previous image; the first (151921) uses the assembled 1A read in its own
|
||||
# raw_s3 capture if that read is whole, else it is skipped (say so in the test). BE9441's 2 images:
|
||||
# before = the assembled READS[0], then image 1. changes = field_values(after) for every field whose
|
||||
# value differs. Assert encode_setup(before, 3, changes)[:2090] == after[:2090].
|
||||
# The 16:26 write also moves [25] (mic on): include `_sensors_mic` as a test-only patch helper,
|
||||
# not a registry field.
|
||||
|
||||
def test_s4_fixture_pairs_reproduce():
|
||||
# for every ordered pair (a, b) of tests/fixtures/micromate-setup/*.bin whose differing bytes outside
|
||||
# [2090:2092] all lie inside registry fields: encode_setup(a, 4, {f: field_values(b)[f] for differing f}) == b
|
||||
|
||||
def test_trigger_checked_against_the_new_range(): ... # Series 3: {"geo_range": "sensitive", "geo_trigger_ips": 2.0} refuses (above 1.25); 1.25 passes; {"geo_trigger_ips": 2.0} alone on Normal passes
|
||||
def test_limits_refuse_outside_values(): ... # 0.004 and 10.001 in/s; 0.3005 (not a 0.001 step); job 0 and 10000; S4 0.9 and 90.1 s;
|
||||
# S3 at 4096 sps: 26 ok, 26.1 refused; S3 histogram_continuous: 13 ok, 13.1 refused;
|
||||
# S3 {"sample_rate": 1024, "record_time_s": 100} passes from a 4096 sps block (the new rate counts);
|
||||
# sample rate 8192; interval 30
|
||||
def test_field_not_offered_for_the_series(): ... # geo_range on series 4 -> SettingsValueError naming the series
|
||||
def test_alarm_is_read_only_until_measured(): ... # Series 3 geo_alarm_ips -> SettingsValueError while S3_ALARM_WRITE_MEASURED is False
|
||||
def test_metric_unit_string_refuses_level_writes(): ... # ch +34 = b"mm\x00\x00" -> SettingsValueError; b"in.\x00" and b"in\x00\x00" pass
|
||||
def test_note_edges(): ... # "" clears; 41 bytes ok; 42 refused; "café" refused
|
||||
def test_note_labels_are_never_written(): ... # changing note_2 moves only [208:250]
|
||||
def test_bit_fields_keep_unknown_bits(): ... # [39] = 0x81: job_number_shown True -> 0x83, False -> 0x81
|
||||
def test_s3_fixed_bytes(): ... # any S3 encode sets [26:28] = 00 00
|
||||
def test_s4_encode_recomputes_the_crc(): ... # crc_ok(encode_setup(fixture, 4, {"job_number": 7}))
|
||||
def test_f32_values_read_back_as_asked(): ... # written = encode(0.3); settings_state(before, written, written) == "as asked"
|
||||
def test_settings_state(): ... # "as asked" / "unchanged" / "differs"; S4 with a bad CRC -> "differs"
|
||||
def test_revision_is_stable_and_content_sensitive(): ...
|
||||
```
|
||||
|
||||
- [ ] **Step 2: Run them.** Expected: FAIL (ModuleNotFoundError: `micromate.setup_fields`).
|
||||
- [ ] **Step 3: Implement** `micromate/setup_fields.py` and `with_crc`. Decode via the registry (not via `decode_setup`, whose notes are keyed by label). Note labels come from the unit and are display only.
|
||||
- [ ] **Step 4: Run them.** Expected: PASS. Then mutation-check `S3_BLASTWARE_FIXED` (remove it: the Blastware-write test fails), delete the `.pyc`, and restore.
|
||||
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(codec): one settings codec for both series, on the shared layout`.
|
||||
|
||||
---
|
||||
|
||||
### Task 3: Micromate — read the schedule file
|
||||
|
||||
**Measured basis:** reference *The scheduler, and a generic file transfer* and *The schedule record format*.
|
||||
- `0x94 <path>` opens a file for read; `offset` = the path's length, and the payload is the path, unpadded.
|
||||
- `0x48` reads the next page, repeated until an all-zero 11-byte response.
|
||||
- The file is 260-byte records. `[4]` is the half-hour slot. `[6]` is the action bitmask: 2 start-with-setup, 4 stop, 8 self-check, 16 ACH. `[7]` is the name length; `[8:260]` is the name.
|
||||
|
||||
**Files:**
|
||||
- Create: `micromate/schedule.py`
|
||||
- Modify: `micromate/protocol.py` (`read_file`), `micromate/client.py`
|
||||
- Modify: `docs/micromate_protocol_reference.md`: one line under the scheduler section saying SFM reads it (read-only) from 2026-11-03.
|
||||
- Test: `tests/test_micromate_schedule.py` (new)
|
||||
|
||||
**Interfaces:**
|
||||
- Produces:
|
||||
- `SCHEDULE_PATH = "\\system\\schedule\\schedule.dat"`.
|
||||
- `MicromateProtocol.read_file(path: str) -> bytes`: the concatenated content of each `0x48` page after the page-0 descriptor, stopping at the all-zero response; at most 64 pages, else `ProtocolError`.
|
||||
- `MicromateClient.read_schedule() -> bytes`.
|
||||
- `MicromateClient.get_active_setup_raw() -> str`: the `0x41` name up to its NUL, **not** stripped.
|
||||
- `MicromateClient.get_prefs_content() -> bytes` (`0x08`), `get_trigger_content() -> bytes` (`0x2E`) and `get_setup_content() -> bytes` (`0x1A`), each `_content(...)` of its read.
|
||||
- `@dataclass(frozen=True) class ScheduleEntry`: `index: int`, `time: str` (`"HH:MM"`), `day: int`, `action_bits: int`, `actions: tuple[str, ...]`, `setup: str`.
|
||||
- `parse_schedule(body: bytes) -> list[ScheduleEntry]`: 260-byte records; a record with `[4:8]` all zero and no name ends the list. `actions` names the bits 2/4/8/16 as `start_with_setup`, `stop`, `self_check` and `call_home`; any other bit becomes `unknown(0xNN)`.
|
||||
- `schedule_conflicts(entries, active_setup: str) -> list[ScheduleEntry]`: start entries whose setup, compared case-insensitively after `strip()`, is not the active setup.
|
||||
|
||||
- [ ] **Step 1: Write the failing tests.** Parse the bodies from `bridges/captures/9-24-26 - micromate2/raw_s3_20260924_191835_read_scheduler.bin` (frames 0–4), and from the two `raw_*_20260925_*` captures, with `MicromateFrameParser`.
|
||||
|
||||
```python
|
||||
def test_the_read_capture_parses(): # 2 records: start-with-setup 07:30 (40-char name), call_home 19:30 (no name)
|
||||
def test_the_five_entry_schedule_parses(): # 07:30 start TEST1.mmb, 08:00 stop, 08:30 self_check, 09:00 start test2.mmb, 19:30 call_home
|
||||
def test_conflicts_are_case_insensitive(): # active "test1.MMB" -> only the test2.mmb start conflicts
|
||||
def test_no_schedule_records_is_no_conflict(): assert schedule_conflicts(parse_schedule(bytes(524)), "x.mmb") == []
|
||||
def test_read_file_sends_the_path_unpadded_and_stops_at_zeros(): ... # a fake protocol: 0x94 offset 0x001D, then 0x48 until all-zero
|
||||
def test_get_active_setup_raw_keeps_spaces(): ... # " LOC 4 .mmb " survives
|
||||
```
|
||||
|
||||
- [ ] **Step 2: Run them.** Expected: FAIL (ModuleNotFoundError: `micromate.schedule`).
|
||||
- [ ] **Step 3: Implement** the Produces block. `read_file` builds `0x94` with `build_request(0x94, len(path), bytes(10), path.encode("ascii"))`. Both SUBs are already in `READ_SUBS`.
|
||||
- [ ] **Step 4: Run them.** Expected: PASS.
|
||||
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(micromate): read the schedule file (read-only)`.
|
||||
|
||||
---
|
||||
|
||||
### Task 4: Change-path pieces and the Series 4 settings change
|
||||
|
||||
**Files:**
|
||||
- Modify: `sfm/device_access/errors.py`, `sfm/device_access/change.py`, `micromate/opcodes.py`, `sfm/device_access/s4.py`, `tests/device_access_fakes.py`
|
||||
- Modify: `tests/test_micromate_execute.py`, `tests/test_micromate_opcodes.py`. Their over-ceiling example `0x71` becomes enableable here; use `0xA8` (delete one event) instead.
|
||||
- Test: `tests/test_device_access_s4_settings.py` (new)
|
||||
|
||||
**Interfaces:**
|
||||
- Consumes:
|
||||
- Task 2: `editable_fields`, `field_values`, `check_changes`, `encode_setup`, `settings_state`, `revision`.
|
||||
- Task 3: `read_schedule`, `parse_schedule`, `schedule_conflicts`, `get_active_setup_raw`, and the content getters.
|
||||
- `micromate.writes.plan_setup_push(prefs, trigger, setup, name)`.
|
||||
- Produces:
|
||||
- `class SettingsChanged(DeviceError)`, `http_status = 409`.
|
||||
- `class ChangeRefused(DeviceError)`, `http_status = 409`.
|
||||
- `settings_change() -> ChangeKind("change settings", "as asked", "applied")`.
|
||||
- `ENABLEABLE_WRITES = frozenset({0x96, 0x97, 0x7E, 0x7F, 0xDA, 0x68, 0x73, 0x82, 0x83, 0x71, 0x72})`.
|
||||
- `s4_settings(client, serial) -> UnitSettings`. It keeps every current field, plus `detail["editable"] = editable_fields(setup, 4)`. The revision comes only from a preview (dry run), never from this read.
|
||||
- `s4_change_settings(client, serial, *, changes: dict, revision: Optional[str], dry_run: bool, audit, address, caller, sleep, verify_timeout_s, verify_interval_s) -> ChangeResult`.
|
||||
|
||||
**`s4_change_settings` behaviour**, through `run_change` (`even_if_already=False`):
|
||||
|
||||
- **`read_state`, first call:**
|
||||
- Read the run state.
|
||||
- `calling_home` and `unknown*` are returned as they are.
|
||||
- `monitoring` raises `UnitStateUnknown(f"{serial} is monitoring -- stop it first (a stop makes it call in if call-home is on) -- nothing sent")`.
|
||||
- Read the name (raw), prefs, trigger and setup.
|
||||
- `check_changes` (a `SettingsValueError` becomes `BadRequest`).
|
||||
- When live, `revision([name.encode("ascii"), prefs, trigger, setup])` must equal the request's. Otherwise raise `SettingsChanged("the unit's settings changed since the preview -- preview again; nothing sent")`.
|
||||
- `image = encode_setup(setup, 4, changes)`.
|
||||
- Read the schedule; a read error is kept as a blocking reason.
|
||||
- Return `settings_state(setup, image, setup, series=4)`.
|
||||
- **Later calls:** read the setup and return `settings_state(before, image, now, series=4)`.
|
||||
- **`describe_plan`:**
|
||||
- `plan_setup_push(prefs, trigger, image, name).describe()`, plus `fields` = `{f: {label, old, new}}` for the changed fields, `revision`, `warnings` and `blocked`.
|
||||
- `warnings` always includes: "this reads the unit's keypad edit buffer: if someone is in its menu, their unsaved edits are sent too".
|
||||
- `blocked`:
|
||||
- the name is `factory.MMB` (case-insensitive): "this unit is running its factory setup; load any other setup on its keypad, then try again";
|
||||
- each schedule conflict: "this unit's schedule loads <setup> at <HH:MM>, which would replace this change";
|
||||
- a schedule read error: "could not read this unit's schedule (<error>) -- SFM will not change a unit whose schedule it cannot check";
|
||||
- `plan_setup_push` raising `ValueError` (a block size or header THOR's offsets were never seen at, or a failed checksum): "this unit's <message> -- SFM has not seen a block like it".
|
||||
- When `blocked` is non-empty, `steps` is `[]`, and a live call raises `ChangeRefused("; ".join(blocked) + " -- nothing sent")`.
|
||||
- When the schedule names the active setup, `warnings` adds: "the unit's schedule loads this setup at <HH:MM>; the change survives it".
|
||||
- **`send`:** `client.protocol.execute(plan)`, as `s4_change_call_home` does.
|
||||
- **`snapshot`:**
|
||||
- `fields`: `{f: {label, old, new, now}}`;
|
||||
- `before` / `after` hex of the setup;
|
||||
- `changed_offsets`;
|
||||
- `prefs` and `trigger`: before hex only.
|
||||
- **`is_refusal`**, **`is_ring`** and **`pre_send`**: as in `s4_change_call_home`.
|
||||
|
||||
**Validation order:** a live call without `revision` is refused before any I/O, in Task 6's `DeviceAccess` (not here).
|
||||
|
||||
- [ ] **Step 1: Write the failing tests.** Extend `FakeMicromateClient` with:
|
||||
- `setup` (default: `tests/fixtures/micromate-setup/um20147_baseline.bin`'s last 2,092 bytes);
|
||||
- `prefs`, `trigger` and `active_name` (default `"test2.mmb"`);
|
||||
- `schedule_body` (default `bytes(524)`) and `schedule_error`;
|
||||
- `execute` applies a setup-push plan's `0x71` data to `self.setup` (re-adding the CRC with `with_crc`), so a read-back sees it.
|
||||
|
||||
```python
|
||||
def test_s4_dry_run_previews_old_to_new_and_sends_nothing(): # fields == {"geo_trigger_ips": {"label": ..., "old": 0.5, "new": 0.3}}; revision present; fake.executed == []
|
||||
def test_s4_trigger_change_sends_the_push_and_verifies(): # subs [0xDA,0x68,0x73,0x82,0x83,0x71,0x72]; outcome sent/ok; state_after "as asked"
|
||||
def test_s4_stale_revision_sends_nothing(): # SettingsChanged; fake.executed == []; audit has no rows
|
||||
def test_s4_already_as_asked_is_skipped(): # outcome skipped, nothing executed
|
||||
def test_s4_monitoring_is_refused(dry_run in (True, False)): # "stop it first" and "nothing sent"
|
||||
def test_s4_factory_setup_is_refused_live_and_shown_in_preview():
|
||||
def test_s4_schedule_conflict_blocks(): # schedule starts "other.mmb" at 07:00 -> ChangeRefused naming other.mmb and 07:00
|
||||
def test_s4_schedule_on_the_active_setup_warns_only():
|
||||
def test_an_unreadable_schedule_refuses():
|
||||
def test_no_schedule_records_is_no_conflict(): # bytes(524) -> sent
|
||||
def test_s4_a_lost_ack_records_what_the_unit_holds(): # execute_error -> outcome failed, sent True, snapshot present
|
||||
def test_s4_unseen_block_size_is_blocked(): # prefs 91 B -> preview blocked; live ChangeRefused; nothing executed
|
||||
def test_setup_push_subs_are_now_enableable():
|
||||
```
|
||||
|
||||
- [ ] **Step 2: Run them.** Expected: FAIL (ImportError: `s4_change_settings`).
|
||||
- [ ] **Step 3: Implement** the Produces block and update `s4_settings`. In the two opcode tests, swap the over-ceiling example to `0xA8`.
|
||||
- [ ] **Step 4: Run them**, plus `tests/test_micromate_execute.py`, `tests/test_micromate_opcodes.py`, `tests/test_micromate_writes.py` (THOR's setup-push frames still reproduce) and `tests/test_device_access_s4_call_home.py`. Expected: PASS.
|
||||
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(s4): change a Micromate's settings by serial, audited, schedule-checked`.
|
||||
|
||||
---
|
||||
|
||||
### Task 5: The Series 3 settings change
|
||||
|
||||
**Files:**
|
||||
- Modify: `sfm/device_access/s3.py`, `minimateplus/client.py` (`push_config_raw` pre-check), `tests/device_access_fakes.py`
|
||||
- Test: `tests/test_device_access_s3_settings.py` (new)
|
||||
|
||||
**Interfaces:**
|
||||
- Consumes:
|
||||
- Task 1: `read_compliance_content`, `read_settings_blocks`, `is_compliance_content`.
|
||||
- Task 2: the codec.
|
||||
- Task 4: `settings_change`, `SettingsChanged`, `ChangeRefused`.
|
||||
- `MiniMateClient.push_config_raw(event_index, compliance, trigger, waveform)`.
|
||||
- Produces:
|
||||
- `push_config_raw` raises `ImageRefused` (from `minimateplus.protocol`) when its pre-check refuses a block, before any frame.
|
||||
- `Series3Adapter.settings(address, serial) -> UnitSettings`. It is built on `read_compliance_content` and the codec, with the same top-level fields as today, plus `detail["editable"]`. A non-settings answer raises `UnitStateUnknown(S3_SETTINGS_WHILE_MONITORING)`.
|
||||
- `S3_SETTINGS_WHILE_MONITORING = "did not return its settings -- a MiniMate answers this way while monitoring; stop monitoring first"`.
|
||||
- `Series3Adapter.change_settings(address, serial, *, changes, revision, dry_run, audit, caller, sleep, verify_timeout_s, verify_interval_s) -> ChangeResult`, through `run_change` and `self._run(address, op, retry=False)`:
|
||||
- `read_serial`: `client.connect().serial`.
|
||||
- **`read_state`, first call:**
|
||||
- Wake, then `read_settings_blocks()`.
|
||||
- A non-settings `compliance` raises `UnitStateUnknown(f"{serial} {S3_SETTINGS_WHILE_MONITORING} -- nothing sent")`.
|
||||
- `check_changes`, and the live revision check over `[event_index, compliance, trigger, waveform]`.
|
||||
- Compute `image = encode_setup(...)` and return `settings_state(...)`.
|
||||
- **Later calls:** wake, `read_compliance_content()`, then the verdict.
|
||||
- **`describe_plan`:**
|
||||
- `steps` in Blastware's order: 68 (event index, as read), 73, 71 (settings block, 2,092 B), 72, 82 (trigger, as read), 83, 69 (waveform data, as read), 74, 72. Each step has `sub`, `what` and `data_len`.
|
||||
- `fields`, `revision` and `warnings` as Series 4. The warning: "the two bytes after the settings block go out as 00 00 (Blastware sends its own constant; effect unmeasured)".
|
||||
- **`send`:** `client.push_config_raw(event_index, image, trigger, waveform)`.
|
||||
- **`is_refusal`:** `isinstance(e, ImageRefused)`.
|
||||
- **`snapshot`:** as Series 4, without prefs and trigger.
|
||||
|
||||
- [ ] **Step 1: Write the failing tests.** Extend `FakeMiniMateClient` with:
|
||||
- `settings_blocks`: the default compliance is BE9441's assembled 10-26 read 2; `event_index`, `trigger` and `waveform` are the `0x68`, `0x82` and `0x69` payloads (`[16:]`) of `WRITES[13:26]` in `tests/test_minimate_write_frames.py`, each minus its two trailing bytes (a write is the read plus two);
|
||||
- `push_config_raw` records its four arguments and makes the compliance the new `read_compliance_content`;
|
||||
- `monitoring_settings=True` returns a device-info-shaped block.
|
||||
|
||||
```python
|
||||
def test_s3_settings_read_uses_the_codec(): # editable includes geo_range; record_mode "histogram"; notes by slot with unit labels
|
||||
def test_s3_dry_run_previews_and_sends_nothing():
|
||||
def test_s3_trigger_change_sends_the_units_own_blocks(): # push args: event_index/trigger/waveform == the read blocks; compliance == encode_setup(...)
|
||||
def test_s3_change_verifies_by_read_back(): # outcome sent/ok, state_after "as asked", snapshot fields old/new/now
|
||||
def test_s3_stale_revision_sends_nothing():
|
||||
def test_s3_monitoring_is_refused(dry_run in (True, False)):
|
||||
def test_s3_a_refused_image_is_audited_as_nothing_sent(): # push_config_raw raises ImageRefused -> row sent 0, "refused before sending"
|
||||
def test_push_config_raw_precheck_raises_image_refused(): # a 2,089-byte compliance block -> ImageRefused, no frame written
|
||||
```
|
||||
|
||||
- [ ] **Step 2: Run them.** Expected: FAIL (AttributeError: `change_settings`).
|
||||
- [ ] **Step 3: Implement** the Produces block.
|
||||
- [ ] **Step 4: Run them**, plus `tests/test_s3_call_home.py`, `tests/test_minimate_write_frames.py` and `tests/test_device_access_*`. Expected: PASS, except the tests Task 6 deletes or rewrites. If one fails here only because it pins `apply_config`, leave it for Task 6 and note that in the ledger.
|
||||
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(s3): change a MiniMate's settings by serial on the shared codec`.
|
||||
|
||||
---
|
||||
|
||||
### Task 6: Device access, the route, and retiring the legacy write
|
||||
|
||||
**Files:**
|
||||
- Modify: `sfm/device_access/access.py`, `sfm/server.py`, `minimateplus/client.py`
|
||||
- Delete: `poc_set_project.py`. Remove `exp_compliance_only` (and its registration) from `experiments.py`.
|
||||
- **Ruling (spec: "the legacy write is retired"):** both write a live unit through the retired encoder, which #46 found wrong. Git keeps them.
|
||||
- Modify tests:
|
||||
- `tests/test_s3_compliance_anchor_fields.py`: remove its write-side tests (the encoder is gone).
|
||||
- `tests/test_minimate_write_frames.py`: `test_apply_config_writes_the_units_own_trigger_block` moves to Task 5's `test_s3_trigger_change_sends_the_units_own_blocks`; delete it here.
|
||||
- `tests/test_server_series3_guard.py`: drop `apply_config` from `WRITES` and its fake method.
|
||||
- `tests/test_server_device_access.py`: `/device/config` now 410.
|
||||
- Test: `tests/test_device_access_settings.py` (new), `tests/test_server_settings_change.py` (new)
|
||||
|
||||
**Interfaces:**
|
||||
- Consumes: Task 4's `s4_change_settings` and Task 5's `Series3Adapter.change_settings`.
|
||||
- Produces:
|
||||
- `DeviceAccess.change_settings(address, serial, *, changes: dict, revision: Optional[str], dry_run: bool = False, caller: str = "api") -> ChangeResult`:
|
||||
- `normalise_serial`, then `series_for_serial`;
|
||||
- `changes` must be a non-empty dict, else `BadRequest`;
|
||||
- a live call without `revision` raises `BadRequest("preview first: a live change needs the revision from its preview -- nothing sent")`;
|
||||
- a live call with no audit log raises `NotSupported` (as `set_call_home`);
|
||||
- `_dispatch(..., change=True)` with `verify_timeout_s=_SETTINGS_VERIFY_TIMEOUT_S = 2.0` and `verify_interval_s=_SETTINGS_VERIFY_INTERVAL_S = 1.0`.
|
||||
- `POST /device/settings/change`:
|
||||
- query: `serial` (required), `host`, `tcp_port`, `port`, `baud`, `dry_run`, `caller`;
|
||||
- JSON body `{"changes": {...}, "revision": "..."}`;
|
||||
- returns `_change_response(...)`;
|
||||
- added to `_SERIAL_AWARE_PATHS`.
|
||||
- `POST /device/config` and `POST /device/config/project` return **410** with `{"detail": "retired: change a unit's settings by serial with POST /device/settings/change (audited, previewed, read back)"}`. Remove the cache-dirty hooks that only these routes called; keep the read routes.
|
||||
- Delete `MiniMateClient.apply_config`, `set_project_info` and `_encode_compliance_config`, and any import left orphaned.
|
||||
|
||||
- [ ] **Step 1: Write the failing tests:**
|
||||
|
||||
```python
|
||||
def test_live_change_without_revision_is_refused_before_io(): # factory never called
|
||||
def test_empty_changes_is_a_bad_request():
|
||||
def test_change_settings_dispatches_by_series_with_change_true():
|
||||
def test_route_dry_run_returns_fields_and_revision(): # 200, body.plan.fields, body.plan.revision
|
||||
def test_route_verified_change_is_200_and_mismatch_409():
|
||||
def test_route_unconfirmed_carries_sent_and_audit_id():
|
||||
def test_route_refusal_is_409_with_reason(): # ChangeRefused / SettingsChanged / monitoring
|
||||
def test_legacy_config_routes_are_gone(): # both 410, nothing reaches a client factory
|
||||
def test_settings_change_is_serial_aware(): # in _SERIAL_AWARE_PATHS; a UM serial goes to the Series-4 path
|
||||
```
|
||||
|
||||
- [ ] **Step 2: Run them.** Expected: FAIL (404 / AttributeError).
|
||||
- [ ] **Step 3: Implement** the Produces block, the deletions, and the test updates listed under Files.
|
||||
- [ ] **Step 4: Run them**, plus `tests/test_server_*.py`. Expected: PASS. Check that `grep -rn "apply_config\|set_project_info\|_encode_compliance_config" --include=*.py .` finds only comments and history.
|
||||
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(sfm): POST /device/settings/change; retire the legacy config write`.
|
||||
|
||||
---
|
||||
|
||||
### Task 7: The page — edit, preview, send, "the unit now holds"
|
||||
|
||||
**Files:**
|
||||
- Modify: `sfm/static/device_routing.js`, `sfm/static/sfm_webapp.js`, `sfm/sfm_webapp.html`
|
||||
- Modify: `CLAUDE.md` (the "Where things stand" Series-4 parity line: phase 5 built, bench pending), and the spec's status line ("Built 2026-11-xx; bench pending").
|
||||
- Test: `tests/test_webapp_device_routing.py` (extend `EXPORTS` and cases), `tests/test_webapp_static.py`
|
||||
|
||||
**Interfaces:**
|
||||
- Consumes: `UnitSettings.detail.editable` / `.revision`, and the `ChangeResult` shapes from Tasks 4–6.
|
||||
- Produces (DOM-free, in `device_routing.js`):
|
||||
- `DEVICE_ROUTES.settings_change = ['POST', '/device/settings/change', true]`; remove `config_write`.
|
||||
- `controlsFor(unit)`: `configWrite: serialMode && (series === 3 || series === 4)`; `reasons.configWrite: 'By serial only: Preview, then Send (audited).'`
|
||||
- `settingsFormFields(st) -> Array<{field, label, kind, value, unit?, min?, max?, choices?, maxlength?, readonly?}>`: from `st.detail.editable`, in that order.
|
||||
- `settingsChanges(fields, edited) -> object`: only fields whose edited value differs. Numbers compare as numbers; read-only fields are ignored.
|
||||
- `settingsPreviewRows(body) -> Array<[label, old, new]>`, from `body.plan.fields`.
|
||||
- `settingsBlockedText(body) -> string`: `body.plan.blocked` joined; `''` if none.
|
||||
- `settingsResultRows(body) -> Array<[label, old, new, now]>`, from `body.detail.snapshot.fields`.
|
||||
- **Page behaviour** (`sfm_webapp.js` glue; HTML ids `cfg-edit`, `cfg-preview-btn`, `cfg-send-btn`, `cfg-preview`, `cfg-result`):
|
||||
- The serial-mode Config pane heading reads **"On the unit <SERIAL> — read <HH:MM>"**.
|
||||
- The form is built from `settingsFormFields`.
|
||||
- **Preview** POSTs a dry run and shows old → new, warnings and blocked reasons. It keeps `revision` and enables **Send** only when nothing is blocked and something changes.
|
||||
- **Send** asks `confirm()` naming the serial and the fields, then POSTs live with the kept revision and shows "the unit now holds" rows. Errors go through `changeErrorText`.
|
||||
- Editing any field after a preview disables **Send** until the next preview.
|
||||
- The by-host legacy form loses its write button. Its read stays.
|
||||
- No inline script; listeners via `addEventListener`.
|
||||
|
||||
- [ ] **Step 1: Write the failing Node-run cases** in `tests/test_webapp_device_routing.py`:
|
||||
- `controlsFor` gives `configWrite` true by serial for both series, and false by host;
|
||||
- `settingsChanges` returns only differing fields and compares `0.30` with `0.3` as equal;
|
||||
- `settingsPreviewRows` / `settingsResultRows` / `settingsBlockedText` on bodies shaped as Task 6 returns them;
|
||||
- `deviceUrl('settings_change', unit)` → `/device/settings/change?serial=…`;
|
||||
- `config_write` is no longer a route.
|
||||
|
||||
In `tests/test_webapp_static.py`, assert the page has no inline `<script>` body and loads both static files.
|
||||
- [ ] **Step 2: Run them.** `…pytest tests/test_webapp_device_routing.py tests/test_webapp_static.py -q`. Expected: FAIL (`settingsChanges` is not a function).
|
||||
- [ ] **Step 3: Implement** the Produces block and the page behaviour.
|
||||
- [ ] **Step 4: Run them.** Expected: PASS. Then run the page under the jsdom harness pattern from phase 4 (`smoke/page_files_load.js` in the scratchpad): the page loads with no console error, and a stubbed dry-run body renders the preview rows.
|
||||
- [ ] **Step 5: Update `CLAUDE.md`** and the spec status line. **Run the full suite** and compare with the baseline. **Commit:** `feat(webapp): edit a unit's settings by serial: preview, send, read back`.
|
||||
|
||||
---
|
||||
|
||||
## After the build: final review, then the bench
|
||||
|
||||
The bench is not a task: it runs after the whole-branch review and its fixes, with Brian at the units, and **each send needs his explicit go**. Run SFM with `ringkit/sfm_parity.py` (port 8299; never 8200). Order:
|
||||
|
||||
1. **Read-only, both units:**
|
||||
- `GET /device/settings` by serial; Brian matches it against each unit's screen.
|
||||
- UM20147: `read_schedule` (measure what a unit with no schedule answers, and whether `0x08` shows the scheduler switch).
|
||||
2. **Dry runs** of a trigger change on each unit. Read the preview with Brian.
|
||||
3. **One field per unit**, with Brian's go:
|
||||
- the trigger (UM20147 0.5 → 0.3; BE9441 0.04 → 0.05);
|
||||
- read back; Brian checks the unit's menu;
|
||||
- change it back, with another go.
|
||||
4. **A notes change** on each (go).
|
||||
5. **A several-field "backup unit" change** on each (go).
|
||||
6. **Refusals:**
|
||||
- a dry run while monitoring (expect the refusal);
|
||||
- UM20147 with a schedule naming another setup, if Brian sets one up in THOR (expect the block).
|
||||
7. **Alarm level (Series 3):**
|
||||
- one write with Brian's go, read back and checked on BE9441's menu;
|
||||
- only then flip `S3_ALARM_WRITE_MEASURED`, in its own commit naming the bench result.
|
||||
|
||||
Record everything in the spec's bench section and both protocol references (measured), then the devlog.
|
||||
@@ -0,0 +1,403 @@
|
||||
# Phase 5: changing a unit's settings by serial (design)
|
||||
|
||||
**Date:** 2026-11-03. **Status:** approved by Brian 2026-11-03; built 2026-11-03
|
||||
(plan `docs/superpowers/plans/2026-11-03-sfm-phase5-settings.md`); **benched 2026-11-04** on both
|
||||
series (results at the end). Phase 5 of
|
||||
`docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md` (row 10, "change
|
||||
recording settings"; build phase 5, "setup push: one field first, then several").
|
||||
**Branch:** `feat/series4-sfm-parity`.
|
||||
|
||||
## Intent (Brian, 2026-11-03)
|
||||
|
||||
Change **any** of a unit's settings from SFM, and make it as easy and reliable as
|
||||
possible. The goal is to fix what makes Blastware finicky. Three real cases:
|
||||
|
||||
- **One wrong number on a deployed unit.** UM6047 was out monitoring with its
|
||||
geophone trigger at 0.03 instead of 0.300. Brian remoted into the THOR PC,
|
||||
stopped it (it called in), changed the setup, made sure it was *sent*, then
|
||||
restarted monitoring.
|
||||
- **A typo in the notes.**
|
||||
- **A backup unit.** The unit set up at the office fails in the field, so a backup
|
||||
from the truck goes in with blank or stale notes and settings. There is no
|
||||
computer in the field, so the office re-does the whole setup remotely, by hand,
|
||||
while the person in the field stands by to press Start or power-cycle if the
|
||||
link breaks.
|
||||
|
||||
What is wrong with THOR, as Brian and his dad experience it:
|
||||
|
||||
- The same screen edits a setup on disk and views a unit's setup.
|
||||
- Setups get saved under random number strings.
|
||||
- Editing a setup does not change the unit; you verify separately that it was sent.
|
||||
|
||||
Saved setups as templates would be acceptable. Not knowing whether you are
|
||||
changing the unit or a file is not.
|
||||
|
||||
## Goals, non-goals, anti-goals
|
||||
|
||||
**Goals**
|
||||
|
||||
- Edit the unit's **live** settings, both series.
|
||||
- Show exactly what will change, **old → new**, before anything is sent.
|
||||
- After sending, **re-read the unit** and show what it now holds.
|
||||
- Make every refusal say why, in plain words.
|
||||
|
||||
**Non-goals (this phase)**
|
||||
|
||||
- Templates, saved setups, copying from another unit.
|
||||
- Restarting monitoring. **Brian presses Start**, as today; SFM never restarts on
|
||||
its own.
|
||||
- Setting the unit's clock. That is a later call-home receiver rule.
|
||||
- **Writing the Micromate scheduler.** Next project, agreed 2026-11-03:
|
||||
"record during work hours" as a plain, **configurable** setting on the unit's
|
||||
page, both series, no schedule library and no setup files. On the Micromate,
|
||||
it relies on the firmware's setup-less scheduler start (found in the firmware,
|
||||
never sent; one bench session). On the MiniMate, its own timer setting
|
||||
(undecoded). Brian's dad despises THOR's scheduler; Brian is willing to retire
|
||||
it in SFM.
|
||||
- Fields not yet decoded. "Any and all" grows as decoding grows.
|
||||
|
||||
**Anti-goals: things that would make it a failure even if it "works"**
|
||||
|
||||
- Any doubt about whether the unit changed.
|
||||
- A screen where a file and a unit look alike, or a name SFM made up.
|
||||
- Writing a byte SFM did not just read. Every byte SFM does not deliberately change
|
||||
goes back exactly as read. The one exception is a byte that Blastware's (or
|
||||
THOR's) own writes always set to a fixed value. Each such byte is named in the
|
||||
codec with its evidence (so far: Series 3 `[26:28]` → `00 00`; my call, below).
|
||||
- Sending to a monitoring unit.
|
||||
- A retry. A write is sent once; what happened is read back.
|
||||
|
||||
## Measured basis
|
||||
|
||||
**1. Series 4 (Micromate): the `0x1A` setup content map.** Measured from 47
|
||||
keypad snapshots on UM20147 and checksum-verified. `micromate/setup_block.py`
|
||||
(`decode_setup`) reads it, with 69 tests on 15 fixtures.
|
||||
|
||||
| content | field |
|
||||
|---|---|
|
||||
| `[5]` | record mode |
|
||||
| `[6:8]` | sample rate |
|
||||
| `[8:10]` | histogram interval |
|
||||
| `[12:16]` | pre-trigger, f32, negative |
|
||||
| `[17]` | stop mode |
|
||||
| `[18:22]` | record time, f32 |
|
||||
| `[23]` | auto-stop |
|
||||
| `[25]` | active sensors |
|
||||
| `[29]` | trigger sources |
|
||||
| `[30:34]` | distance |
|
||||
| `[34:38]` | charge |
|
||||
| `[39]` | report flags |
|
||||
| `[40:42]` | job number |
|
||||
| `[42:86]` | setup name |
|
||||
| `[122+64n]` / `[144+64n]` | notes (label / value) |
|
||||
| from `[1708]` | 48-byte channel blocks: sensor code `+4:8`, trigger `+30` (geo in/s, mic psi) |
|
||||
|
||||
The CRC-16/AUG-CCITT over `[0:2088]` is stored at `[2090:2092]`; THOR's write
|
||||
omits it and the unit recomputes it.
|
||||
|
||||
- **The push sequence (from THOR's captures)** is `0xDA` (name) → `0x68`/`0x73`
|
||||
(`0x08` preferences) → `0x82`/`0x83` (`0x2E` trigger) → `0x71`/`0x72` (`0x1A`
|
||||
setup). `micromate.writes.plan_setup_push` reproduces THOR's frames (phase 2).
|
||||
- **Not yet mapped on Series 4:** alarm level, geophone range, GPS, aux I/O, SLM
|
||||
options.
|
||||
|
||||
**2. Series 3 (MiniMate) uses the same layout. Measured 2026-11-03.** The
|
||||
compliance image as Blastware writes it is logical (unescaped), 2,092 bytes, with
|
||||
`N = 2090` at `[0:2]` and the channel block "Tran" at `[1708]`.
|
||||
`micromate.setup_block.decode_setup` reads it correctly:
|
||||
|
||||
- **BE9441's 10-26 write** (`tests/fixtures/minimate-bench-10-26-26-histogram`,
|
||||
two whole sends): name, mode, 4096 sps, interval, record time 20 s, trigger
|
||||
0.04 in/s, mic linear, job number and the notes all decode. Only the CRC fails
|
||||
(Series 3's tail goes out stale).
|
||||
- **BE11529's nine 2026-04-20 Blastware writes** (`bridges/captures/4-20-26/`,
|
||||
every one with a whole image) each changed exactly the expected bytes:
|
||||
|
||||
| Blastware changed | bytes that moved |
|
||||
|---|---|
|
||||
| histogram interval (×4) | `[8:10]` |
|
||||
| recording mode (×3) | `[5]` |
|
||||
| geophone range | `1737` / `1785` / `1833`, the range byte at each geophone channel label `+29` |
|
||||
|
||||
- **The live `SUB 1A` read starts the same block.** Measured on the first data
|
||||
frame of each of the four recorded reads (`_settings_replies` in
|
||||
`tests/test_s3_compliance_anchor_fields.py`): unescaped, each carries `N = 2090`
|
||||
12 bytes before the old "anchor", and content `[5]` reads 1 / 4 / 3 / 3. That
|
||||
anchor (`be 80 00 00 00 00`) is content `[12:18]`, pre-trigger −0.25 plus stop
|
||||
mode Fixed. So Series 3 can be read by content offset rather than by anchor
|
||||
search, which survives an Auto-stop unit (the open question of 2026-10-17).
|
||||
- **A whole `1A` read assembles to exactly the 2,090 content bytes** (measured
|
||||
2026-11-03 on BE9441's 10-26 recording, 12 reads). Unescape each data frame and
|
||||
take `data[11:]`. Every frame but the last then starts with one `00` byte that is
|
||||
not content; drop it. This holds for Blastware's read (four 512-byte frames plus
|
||||
42) and SFM's (two 1024-byte frames plus 42).
|
||||
- **The round trip is exact.** Blastware re-read the block after each of its two
|
||||
writes, and each re-read equals the image it had just written, all 2,090 bytes.
|
||||
- **While monitoring**, the read returns `0e 'BE9441' …` (the device-info block),
|
||||
as the 10-29 finding says. The unit was monitoring for 5 of the 12 reads.
|
||||
- **Bytes `[26:28]`: Blastware always writes `00 00`** (all 11 writes), though the
|
||||
unit reads `01 7f` after a monitoring session (BE9441 10-26, BE11529 4-20 15:19).
|
||||
The unit sets them again by itself. Meaning unknown.
|
||||
- **The two bytes after the block are Blastware's own.** Blastware sends a per-unit
|
||||
constant: `7c ea` on all nine of BE11529's writes, `0c e9` on both of BE9441's.
|
||||
It is not the block's CRC-16/AUG, and no reply in BE9441's three-hour session
|
||||
contains it. SFM's `write_image` sends `00 00` there. Since a read never returns
|
||||
those bytes, the read-back cannot show what the unit did with them.
|
||||
- **The mode byte is shared, but its codes are not.** Series 3: `00` Single Shot,
|
||||
`01` Continuous, `03` Histogram, `04` Histogram + Continuous. Series 4: `01`
|
||||
Waveform, `02` Manual, `03` Histogram, `04` Combo.
|
||||
- **Rules from the checker's file-side work** (seismo-relay-b6, 2026-11-03; it
|
||||
measured the same content offsets on 70,042 event files and found nothing that
|
||||
contradicts one shared map):
|
||||
- A bitmask byte is patched **bit by bit, never rebuilt**. The trigger-sources
|
||||
byte `[29]` showed an unidentified `0x80` bit on one unit.
|
||||
- On Series 3, stop mode (`0` Fixed) and mic type (`2` linear) are proven for
|
||||
one value each. They are not offered for writing.
|
||||
- An event file's `[12:16]` is that event's captured pre-trigger, not the
|
||||
setting. SFM writes only from a live read, so this matters only to anyone
|
||||
tempted to build a write from a file.
|
||||
- **Series-3-only fields** (measured on Series 3, not Series 4): the geophone range
|
||||
byte at channel `+29`; the alarm level at channel `+38` (checker-measured on
|
||||
event files; live raw `+42`).
|
||||
|
||||
**3. Series 3 write frames are measured (#46).** Writes use uniform escaping with
|
||||
a length field. The compliance image goes in 512-byte addressed chunks. `0x68` is
|
||||
written as read plus `02 00`, `0x82` plus `00 00`. The sequence is
|
||||
`68→73 | 71×n→72 | 82→83 | 69→74→72`. `push_config_raw` refuses any block that
|
||||
is not whole. `tests/test_minimate_write_frames.py` rebuilds Blastware's frames
|
||||
byte for byte.
|
||||
|
||||
**4. Monitoring.**
|
||||
|
||||
- **Series 3:** while monitoring, the unit answers `1A` (and `0x2C`) with its
|
||||
device-info block (measured 10-29 and 11-03).
|
||||
- **Series 4:** it refuses call-home setup while monitoring ("Feature disabled
|
||||
while monitoring", measured 11-03).
|
||||
- **A stop with call-home on makes the unit call in** (measured 10-25, 10-29,
|
||||
11-03).
|
||||
|
||||
**5. Series 4 specifics.**
|
||||
|
||||
- `0x1A` reads the keypad's edit buffer live: unsaved keypad edits show in the
|
||||
read, and a push would commit them.
|
||||
- Loading a `.MMB` replaces the active config byte for byte. The push writes
|
||||
under the active setup's name (`0xDA`).
|
||||
|
||||
## The flow
|
||||
|
||||
1. **Read.** `GET /device/settings?serial=…` (it exists) returns the unit's
|
||||
settings. The page shows them on the Config tab under **"On the unit BE9441 —
|
||||
read 14:03"**, never anything that looks like a file.
|
||||
2. **Edit and preview.** The operator changes fields, then **Preview**: a dry run.
|
||||
SFM re-reads the unit's blocks on the same line, builds the new blocks, and
|
||||
returns one row per field: **old → new**, plus any warnings. Nothing is sent.
|
||||
3. **Send.** The same request, live, is an audited change:
|
||||
- identity check, audit row, one send, never retried, read back;
|
||||
- **refused with "stop monitoring first"** if the unit is monitoring, noting
|
||||
that the stop makes it call in when call-home is on;
|
||||
- **refused** if the unit's settings changed since the preview. The preview
|
||||
carries a revision (a hash of the blocks read), and the live call must
|
||||
match it.
|
||||
4. **Verify.** Re-read the blocks. Every changed field must read its new value.
|
||||
Every other decoded field, and every byte SFM did not deliberately change, must
|
||||
read as before. The page shows **"the unit now holds"**: field, old, new, now.
|
||||
Known unit-maintained bytes (the Series-4 CRC) are compared as the unit's own
|
||||
checksum (`crc_ok`), not byte for byte.
|
||||
5. **Start** stays the operator's button.
|
||||
|
||||
## Fields in the first version (Brian approved the list)
|
||||
|
||||
| field | Series 3 | Series 4 |
|
||||
|---|---|---|
|
||||
| geophone trigger level | yes (channel `+30`) | yes (channel `+30`) |
|
||||
| alarm level | yes (channel `+38`; measure live) | not mapped, so not offered |
|
||||
| notes: the four note slots, by the unit's own labels | yes (`Project:`, `Client:`, `User Name:`, `Seis. Loc:` on BE9441) | yes (`Location`, `Client`, `Company`, `General Notes`) |
|
||||
| recording mode | yes (`[5]`; values as measured on Series 3) | yes (`[5]`; Series-4 codes) |
|
||||
| sample rate | yes | yes |
|
||||
| record time | yes | yes |
|
||||
| histogram interval | yes | yes |
|
||||
| geophone range | yes (channel `+29`) | not mapped, so not offered |
|
||||
| job number (+ shown on report) | yes | yes |
|
||||
|
||||
A field is offered only where it is measured for that series. Values are refused
|
||||
unless they are among the measured choices: sample rates 1024/2048/4096,
|
||||
intervals 2/5/15/60/300/900 s, and each series' measured mode codes.
|
||||
|
||||
- **Numbers: the units' own limits (Brian, 2026-11-03: "I want to use the actual
|
||||
unit limits, not just what we have done in the past").** From Instantel's
|
||||
operator manuals in `~/seismo-relay/manuals/`:
|
||||
- **Geophone trigger:** 0.005–10 in/s in steps of 0.001 (MiniMate Plus manual
|
||||
716U0101 Rev 15, Appendix *Series III Specifications*; Micromate manual
|
||||
721U0201 Rev 06, *Geophone Trigger Level*). It is also capped at the range's
|
||||
full scale (10 / 1.25 in/s). When range and trigger change in one request,
|
||||
check the trigger against the **new** range.
|
||||
- **Record time:**
|
||||
- Micromate: 1–90 s (*Record Time*).
|
||||
- MiniMate: from 1 s to the manual's §4.4 *Maximum Record Times* for a
|
||||
1 MB unit, four channels, at the chosen sample rate: 104 s at 1024 sps,
|
||||
52 s at 2048, 26 s at 4096. In Histogram Combo, 13 s (§3.8.9). The units
|
||||
measured report about 960 KB in total memory (BE11529: 983,026 bytes), the
|
||||
1 MB model.
|
||||
- **Job number:** 1–9999 (both manuals).
|
||||
- **The read-back is the safety net.** A unit that does not take a value (for
|
||||
instance, cuts a record time to what its memory allows) shows as not taken,
|
||||
with what it actually holds.
|
||||
- Values seen across 75,958 Blastware reports (2016–2026) sit well inside these
|
||||
limits: trigger 0.005–0.500 in/s, record time 1–10 s, job number 1.
|
||||
- **Units:** refuse a level write unless the channel's unit string reads the
|
||||
measured one (`in.` for a geophone). A unit set to Metric is unmeasured.
|
||||
- **Notes:** edited by slot, under the label the unit itself shows (labels can be
|
||||
renamed and are not identifiers). The value is at most its field width less
|
||||
one byte, printable ASCII.
|
||||
- Not in v1: Series 3's fifth slot, `Extended Notes` (value `\n` on BE9441).
|
||||
Blastware's extended notes are unmeasured and may live elsewhere.
|
||||
- Not in v1: Series 4's 16-byte field at content `[1064]` (`Loc 1` on
|
||||
UM12947), undecoded.
|
||||
|
||||
## Architecture
|
||||
|
||||
- **One setup-block codec for both series.** Keep `micromate/setup_block.py` as
|
||||
the field map and add `encode_setup(content, changes) -> content`: field patches
|
||||
only, every other byte as given. It stays a pure codec library: no I/O, no
|
||||
`sfm` imports, no import cycle with `minimateplus`. Series-specific fields (the
|
||||
Series-3 range and alarm) are marked by series.
|
||||
- **Series 3 read.** Assemble the `1A` read into the logical 2,090-byte block:
|
||||
unescape, strip the 12-byte reply prefix and the inter-frame headers
|
||||
(`read_compliance_config`). Decode it by content offset.
|
||||
- **Series 3 write.** The patched logical block plus the tail becomes the
|
||||
compliance image for `push_config_raw`. Event index (`0x08`), trigger (`0x2E`)
|
||||
and waveform data (`0x09`) are echoed as read, in Blastware's sequence.
|
||||
- On `0x09`, Blastware echoed the unit's bytes on all nine April writes
|
||||
(`[200:202]` = `8c 76` read and written). Only BE9441's 10-26 writes changed
|
||||
them (`17 17` read, `78 76` written, and read back so). The meaning is
|
||||
unknown, so SFM echoes.
|
||||
- **The raw-offset `_encode_compliance_config` is retired.**
|
||||
- **The legacy write (`/device/config`, `/device/config/project`) is retired (my
|
||||
call).** It retries a whole write on a TCP error, is not audited, does no
|
||||
read-back, does not refuse a monitoring unit, and needs no serial: every
|
||||
anti-goal at once. Its only user is the webapp's by-host Config form, and
|
||||
Terra-View does not call it. Its routes answer with a pointer to the by-serial
|
||||
change, and the by-host form becomes read-only.
|
||||
- **Series 4 write.** `plan_setup_push(prefs, trigger, patched_setup, name)`.
|
||||
- **No setup files in the operator's view (Brian, 2026-11-03).** "We treat the
|
||||
Micromate setups just like Minimate setups … the unit just has its settings,
|
||||
and we change it based on the job. We don't send setups to the unit." A
|
||||
backup unit is usually on whatever setup its previous job left. So SFM
|
||||
rewrites the setup the unit is running, in place, under its own name. It
|
||||
never asks for a file or a name, and never creates one. The name may show as
|
||||
a read-only detail, since the unit's screen shows it.
|
||||
- **The scheduler can undo a change (Brian, 2026-11-03, with THOR's Manage
|
||||
Schedules screen).** Work-hours Micromates run a THOR schedule, e.g. Start
|
||||
Monitoring 07:00 with setup `Mele-PWSA-Carroll -Loc 4`, stop 18:30, repeat
|
||||
daily. THOR sends the schedule with its setup, and each scheduled start loads
|
||||
the setup it names. So the preview and the send read `schedule.dat` (format
|
||||
decoded, reference *The schedule record format*), read-only. A start action
|
||||
naming a setup other than the one being changed blocks the send: "this unit's
|
||||
schedule loads <name> at 07:00, which would replace this change." When the
|
||||
schedule names the active setup (the usual case after a scheduled start), the
|
||||
change survives, and the preview says when the next scheduled start is.
|
||||
SFM never writes the schedule in this phase.
|
||||
- The name comes from the `0x41` read, unstripped.
|
||||
- Refuse `factory.MMB` and any target that is not the active setup (spec). The
|
||||
refusal says it plainly: "this unit is running its factory setup; load any
|
||||
other setup on its keypad, then try again." Brian says the team does not use
|
||||
the factory setup, so this should be rare.
|
||||
- `ENABLEABLE_WRITES` gains `0xDA 0x68 0x73 0x82 0x83 0x71 0x72`.
|
||||
- The keypad edit buffer: warn in the preview that a unit with someone in its
|
||||
menu would have those edits committed. The check the spec names, `0x1A`
|
||||
against the active `.MMB` via `0x94`/`0x48`, is a bench question first.
|
||||
- **The change path.** It keeps run_change's guarantees: identity, audit, one
|
||||
send, read back, `ChangeUnconfirmed` with `sent`/`audit_id`. The "state" is a
|
||||
set of fields, so either `run_change` takes a verify function or a sibling core
|
||||
shares its parts. The builder decides; the guarantees do not change. The audit
|
||||
row keeps the per-field changes, both blocks (hex) and the verdict.
|
||||
- **Routes.** `POST /device/settings/change?serial=…` (serial required) with body
|
||||
`{changes: {field: value}, revision}` and `dry_run`, `caller`. The response is
|
||||
per-field `old` / `new` / `now`, through `_change_response`. A dry run needs no
|
||||
revision and returns one. **A live call without the revision of a preview is
|
||||
refused** (my call): nothing reaches a unit unless someone saw old → new.
|
||||
- **Page.** The Config tab by serial becomes the unit's edit form: Preview → Send
|
||||
(confirm) → "the unit now holds". New logic goes in
|
||||
`sfm/static/device_routing.js` with Node tests, and glue in
|
||||
`sfm/static/sfm_webapp.js` (no inline JS).
|
||||
|
||||
## Verification
|
||||
|
||||
- **Series 3, byte for byte.** For each of the 11 Blastware compliance writes,
|
||||
apply the new encoder to the read before it (or the previous image), with the
|
||||
fields Blastware changed. It must reproduce Blastware's content `[0:2090]`. The
|
||||
two trailing bytes are compared separately, since they are Blastware's constant.
|
||||
Ten writes change one field. BE9441's 16:26 write changes five things: mode,
|
||||
sample rate 2048 → 4096, interval, the mic in the sensors byte `[25]`, and
|
||||
`[26:28]`. That one is tested with all of them, through the codec, though v1's
|
||||
page does not offer the sensors byte.
|
||||
The frames rebuild through `push_config_raw`'s path (the #46 tests).
|
||||
- **Series 3, read side.** The assembly rule above, pinned as a test on the 12
|
||||
reads of BE9441's 10-26 recording. Each read-back equals the write before it.
|
||||
- **Series 4.** THOR's setup-push captures still reproduce, with no field changed.
|
||||
Any capture where THOR changed a field becomes a byte-for-byte test.
|
||||
- **Bench, with Brian's go per send, per series:**
|
||||
1. A dry run of a trigger change, then send, read back, check the unit's menu,
|
||||
and change it back.
|
||||
2. A notes change.
|
||||
3. A several-field "backup unit" change.
|
||||
4. A dry run while monitoring, expecting the refusal.
|
||||
|
||||
## Bench 2026-11-04 (results)
|
||||
|
||||
Brian at BE9441 and UM20147, each on its own modem; every send with his go.
|
||||
Notes: `~/bench-logs/2026-11-04-sfm-settings/`.
|
||||
|
||||
- **Both series change correctly.** Each change was acknowledged, read back as
|
||||
sent, and confirmed on the unit's own screen; both units ended byte for byte as
|
||||
found.
|
||||
- BE9441: trigger each way, a note, several fields at once, the alarm, a full
|
||||
restore.
|
||||
- UM20147: trigger, several fields (two notes, job number and its flag, record
|
||||
time), a full restore. The unit's recomputed CRC equalled SFM's.
|
||||
- **Fixed at the bench (`9992b25`):** the first live MiniMate read came back one
|
||||
byte long. An escaped checksum byte leaves its `0x10` behind (about 1 frame in
|
||||
85; the recordings never had it). The read now takes exactly the lengths it
|
||||
asked for, and so does the waveform read (`c790e20`).
|
||||
- **🔑 The keypad menu wins.** A MiniMate change sent while its setup menu is
|
||||
open is acknowledged and read back, then lost when the operator presses Cancel
|
||||
or Save: the menu writes its copy of the whole block back. SFM cannot see this
|
||||
happen; the MiniMate preview now warns. Rule for the field-plus-office routine:
|
||||
nobody in the unit's menus while the office sends.
|
||||
- **The MiniMate alarm write is measured**, so it is now writable (`55c7b7b`).
|
||||
- **Refused while recording, both series, nothing sent.** A recording MiniMate
|
||||
sometimes leaves a preview at "no answer" rather than the refusal.
|
||||
- **The Micromate scheduler switch is in no block SFM reads.** UM20147 carries a
|
||||
leftover THOR schedule (Fay setup, 07:00 daily) with the switch Off; SFM blocks
|
||||
it, a false alarm here. The bench used a scratch-only override.
|
||||
- Next: a THOR bridge recording to find the switch (parked for work hours).
|
||||
- Meanwhile, worth considering: let the operator confirm "scheduler off" in the
|
||||
preview.
|
||||
|
||||
## Calls I made (Claude), for Brian to check
|
||||
|
||||
- **Series 3 `[26:28]` goes out as `00 00`, as Blastware writes it**, rather than
|
||||
the `01 7f` the unit may read. Measured beats inferred: Blastware's value is on
|
||||
11 accepted writes, and writing back `01 7f` has never been tried.
|
||||
- **The two bytes after the Series 3 block stay `00 00`**, as `write_image` sends
|
||||
them (a unit accepted that in the April 2026 test). Blastware's per-unit
|
||||
constant cannot be derived from anything SFM reads. The first bench write checks
|
||||
that the unit takes the block, and its menu shows the change.
|
||||
- **The `0x09` block is echoed as read**, as Blastware did on all nine April writes.
|
||||
- **Level writes are refused unless the channel's unit string is the measured
|
||||
`in.` / `in`** (a unit set to Metric is unmeasured).
|
||||
- **Notes are edited by slot under the unit's own labels**, four slots on each
|
||||
series. Series 3 extended notes and Series 4's separate location field wait.
|
||||
- **The legacy by-host write is retired**; the by-host form becomes read-only.
|
||||
- **A live send needs a preview's revision.**
|
||||
- **Preview re-reads the unit** rather than trusting the page's copy, and Send
|
||||
refuses if the unit changed since the preview.
|
||||
- **The edit form lives on the Config tab, by serial**, replacing the legacy
|
||||
read-modify-write form for units reached by serial.
|
||||
|
||||
## Left to the builder
|
||||
|
||||
- The module layout for the shared codec, within the no-cycle, pure-codec rule.
|
||||
- `run_change` generalised versus a sibling core.
|
||||
- The exact revision hash.
|
||||
- Page layout details.
|
||||
-107
@@ -60,7 +60,6 @@ from minimateplus.framing import build_bw_frame, SESSION_RESET
|
||||
from minimateplus.client import (
|
||||
MiniMateClient,
|
||||
_decode_compliance_config_into,
|
||||
_encode_compliance_config,
|
||||
)
|
||||
from minimateplus.models import DeviceInfo
|
||||
|
||||
@@ -462,111 +461,6 @@ def exp_fewer_polls(host: str, port: int) -> tuple[str, str, dict]:
|
||||
t.disconnect()
|
||||
|
||||
|
||||
# ══════════════════════════════════════════════════════════════════════════════
|
||||
# EXP6 — Compliance-only write (71×3→72), skip event index + trigger + waveform
|
||||
# ══════════════════════════════════════════════════════════════════════════════
|
||||
#
|
||||
# Blastware's full write sequence: 68→73 | 71×3→72 | 82→83 | 69→74→72
|
||||
# We want to know: can we write ONLY the compliance block (71×3→72)?
|
||||
#
|
||||
# Test procedure:
|
||||
# 1. Read current compliance config (SUB 1A)
|
||||
# 2. Patch the "notes" field to a test marker
|
||||
# 3. Write ONLY 71×3→72 (skip 68, 73, 82, 83, 69, 74, final 72)
|
||||
# 4. Read back (SUB 1A) and verify the change was written
|
||||
# 5. Restore original value
|
||||
#
|
||||
# If PASS: we can push individual config fields without touching event index,
|
||||
# trigger config, or waveform data — huge simplification.
|
||||
# If FAIL: the device needs the full write sequence (may reject partial write).
|
||||
#
|
||||
# SAFETY: We restore original data in a finally block. If the restore write
|
||||
# fails, the device will have the test marker in "notes" — harmless but visible.
|
||||
|
||||
_EXP6_MARKER = "[exp6-test]"
|
||||
|
||||
def exp_compliance_only(host: str, port: int) -> tuple[str, str, dict]:
|
||||
"""Write compliance block alone (71×3→72), verify, and restore."""
|
||||
client, info = connect_client(host, port)
|
||||
original_raw: Optional[bytes] = None
|
||||
try:
|
||||
proto = client._proto
|
||||
if proto is None:
|
||||
return "FAIL", "Could not get protocol handle from client", {}
|
||||
|
||||
# 1. Read current compliance
|
||||
print(" Reading current compliance config (SUB 1A)…")
|
||||
original_raw = proto.read_compliance_config()
|
||||
print(f" Got {len(original_raw)} bytes of compliance config")
|
||||
|
||||
# Find current notes value for display
|
||||
info_obj = DeviceInfo()
|
||||
_decode_compliance_config_into(original_raw, info_obj)
|
||||
cc = info_obj.compliance_config
|
||||
orig_notes = cc.notes if cc else "(unknown)"
|
||||
print(f" Current notes field: {orig_notes!r}")
|
||||
|
||||
# 2. Build modified payload with test marker in notes
|
||||
test_notes = _EXP6_MARKER
|
||||
modified_raw = _encode_compliance_config(
|
||||
original_raw,
|
||||
notes=test_notes,
|
||||
)
|
||||
print(f" Encoded modified compliance payload ({len(modified_raw)} bytes)")
|
||||
print(f" Patching notes: {orig_notes!r} → {test_notes!r}")
|
||||
|
||||
# 3. Write ONLY the compliance block: 71×3 → 72
|
||||
print(" Writing compliance ONLY (71×3→72) — skipping 68/73/82/83/69/74…")
|
||||
proto.write_compliance_config_raw(modified_raw)
|
||||
print(" Write complete — device acked 71×3→72")
|
||||
|
||||
# 4. Read back and verify
|
||||
print(" Reading back compliance config to verify…")
|
||||
readback_raw = proto.read_compliance_config()
|
||||
readback_info = DeviceInfo()
|
||||
_decode_compliance_config_into(readback_raw, readback_info)
|
||||
rb_cc = readback_info.compliance_config
|
||||
readback_notes = rb_cc.notes if rb_cc else "(decode failed)"
|
||||
print(f" Read-back notes: {readback_notes!r}")
|
||||
|
||||
write_worked = (readback_notes == test_notes)
|
||||
print(f" Write verified: {write_worked}")
|
||||
|
||||
details = {
|
||||
"original_notes": orig_notes,
|
||||
"written_notes": test_notes,
|
||||
"readback_notes": readback_notes,
|
||||
"write_verified": write_worked,
|
||||
}
|
||||
|
||||
if write_worked:
|
||||
return "PASS", "Compliance-only write works! No event index or trigger writes needed.", details
|
||||
else:
|
||||
return "FAIL", f"Write was not reflected in read-back (got {readback_notes!r})", details
|
||||
|
||||
except ProtocolError as exc:
|
||||
return "FAIL", f"Protocol error: {exc}", {}
|
||||
|
||||
finally:
|
||||
# Restore original compliance data regardless of outcome
|
||||
if original_raw is not None:
|
||||
print(" Restoring original compliance config…")
|
||||
try:
|
||||
proto2 = client._proto
|
||||
if proto2:
|
||||
proto2.write_compliance_config_raw(
|
||||
_encode_compliance_config(original_raw) # no-op patch = verbatim
|
||||
)
|
||||
print(" Restore complete")
|
||||
else:
|
||||
print(" WARNING: protocol handle gone — could not restore")
|
||||
except Exception as exc_r:
|
||||
print(f" WARNING: restore failed: {exc_r}")
|
||||
client.close()
|
||||
|
||||
|
||||
# ══════════════════════════════════════════════════════════════════════════════
|
||||
# Registry + main
|
||||
# ══════════════════════════════════════════════════════════════════════════════
|
||||
|
||||
EXPERIMENTS = {
|
||||
@@ -575,7 +469,6 @@ EXPERIMENTS = {
|
||||
"no_5a": ("EXP3", exp_no_5a, "Event record (0C) without bulk waveform (5A)"),
|
||||
"skip_1e": ("EXP4", exp_skip_1e, "0A/0C with cached key — skip initial 1E"),
|
||||
"fewer_polls": ("EXP5", exp_fewer_polls, "1 POLL before 5A instead of Blastware's 3"),
|
||||
"compliance_only": ("EXP6", exp_compliance_only, "Compliance-only write (71×3→72), no other blocks"),
|
||||
}
|
||||
|
||||
|
||||
|
||||
@@ -48,6 +48,7 @@ from .models import (
|
||||
MicromateState,
|
||||
)
|
||||
from .protocol import MicromateProtocol, ProtocolError
|
||||
from .schedule import SCHEDULE_PATH
|
||||
from .setup_block import decode_setup
|
||||
|
||||
log = logging.getLogger(__name__)
|
||||
@@ -333,6 +334,28 @@ class MicromateClient:
|
||||
"""`SUB 0x41` — the loaded `.MMB` file name, e.g. `TEST1.mmb`."""
|
||||
return _cstring(_content(self._proto.read_active_setup_name()))
|
||||
|
||||
def get_active_setup_raw(self) -> str:
|
||||
"""The `0x41` name exactly as stored, up to its NUL -- NOT stripped, so a
|
||||
setup push writes back the very name the unit holds."""
|
||||
return _content(self._proto.read_active_setup_name()).split(b"\x00")[0].decode("ascii", "replace")
|
||||
|
||||
def get_prefs_content(self) -> bytes:
|
||||
"""`SUB 0x08` -- the preferences block's content (a setup push sends it back)."""
|
||||
return _content(self._proto.read_event_index())
|
||||
|
||||
def get_trigger_content(self) -> bytes:
|
||||
"""`SUB 0x2E` -- the trigger block's content (a setup push sends it back)."""
|
||||
return _content(self._proto.read_trigger_config())
|
||||
|
||||
def get_setup_content(self) -> bytes:
|
||||
"""`SUB 0x1A` -- the setup block's content, undecoded (2,092 B, CRC last).
|
||||
⚠ The keypad's edit buffer: unsaved menu edits come back too."""
|
||||
return _content(self._proto.read_compliance_config())
|
||||
|
||||
def read_schedule(self) -> bytes:
|
||||
"""`schedule.dat`, read-only (`micromate.schedule.parse_schedule` reads it)."""
|
||||
return self._proto.read_file(SCHEDULE_PATH)
|
||||
|
||||
def get_setup(self, *, verify: bool = True) -> MicromateSetup:
|
||||
"""`SUB 0x1A` — what the unit is set to, decoded. One read.
|
||||
|
||||
|
||||
@@ -86,7 +86,10 @@ READ_SUBS: Mapping[int, str] = MappingProxyType(_READ_SUBS)
|
||||
# (0xA8/0xAA), raw file writes (0x8D/0x8E -- they could reach the modem
|
||||
# settings) and 0xA2 never belong here without one. Phase 4 (2026-11-02) added
|
||||
# the call-home write and its confirm (spec row 9: enable/disable only).
|
||||
ENABLEABLE_WRITES = frozenset({0x96, 0x97, 0x7E, 0x7F})
|
||||
# Phase 5 (2026-11-03) added the setup push -- name, preferences, trigger and setup
|
||||
# blocks with their confirms -- for changing a unit's settings by serial (spec row 10).
|
||||
ENABLEABLE_WRITES = frozenset({0x96, 0x97, 0x7E, 0x7F,
|
||||
0xDA, 0x68, 0x73, 0x82, 0x83, 0x71, 0x72}) # + the setup push (phase 5)
|
||||
|
||||
|
||||
class OpcodeRefused(RuntimeError):
|
||||
|
||||
@@ -93,6 +93,8 @@ SUB_STATE = 0x49
|
||||
SUB_BULK_DOWNLOAD = 0x5A
|
||||
SUB_POLL = 0x5B
|
||||
SUB_ARM_EVENT = 0x93
|
||||
SUB_FILE_READ_NEXT = 0x48 # file transfer: next page of the file opened by 0x94
|
||||
SUB_FILE_OPEN_READ = 0x94 # file transfer: open a file by path, for reading
|
||||
|
||||
# ⚠ Reads are SINGLE-STEP. Series III probes at offset 0 to learn the length,
|
||||
# then reads again at that length; a Micromate returns the whole block when
|
||||
@@ -102,6 +104,10 @@ READ_ALL = 0xFFFF
|
||||
|
||||
# The two commands that do NOT use READ_ALL, and the data length each returned
|
||||
# on UM12947 (firmware 11.0CB).
|
||||
_FILE_OPEN_PARAMS = bytes([0, 0, 0, 1, 0, 0, 0, 0, 0, 0])
|
||||
_FILE_FIRST_PAGE_PARAMS = bytes([0, 0, 0, 0, 0, 0, 0, 1, 0, 0])
|
||||
_MAX_FILE_PAGES = 64
|
||||
|
||||
_OFFSETS = {
|
||||
SUB_POLL: 0x0030, # 59 B — the one offset THOR treats as a constant
|
||||
SUB_SERIAL: 0x000A, # 21 B
|
||||
@@ -376,6 +382,31 @@ class MicromateProtocol:
|
||||
"""
|
||||
return self._read(SUB_SETUP_NEXT)
|
||||
|
||||
# ── Files, by path (read-only) ────────────────────────────────────────────
|
||||
|
||||
def read_file(self, path: str) -> bytes:
|
||||
"""A file off the unit, by full path: `0x94` + the path opens it, then
|
||||
`0x48` pages follow until an all-zero reply. The first `0x48` reply is a
|
||||
descriptor, not file content. Frames are THOR's exactly (UM12947 reading
|
||||
`schedule.dat`, 2026-09-24): `0x94` carries `params[3] = 1` and the path,
|
||||
unpadded, as data with offset = its length; the first `0x48` carries
|
||||
`params[7] = 1`, the rest none. Returns the content (each page's data
|
||||
after its 11-byte prefix), joined.
|
||||
"""
|
||||
raw = path.encode("ascii")
|
||||
self._request(build_request(SUB_FILE_OPEN_READ, len(raw), _FILE_OPEN_PARAMS, raw),
|
||||
0xFF - SUB_FILE_OPEN_READ)
|
||||
body = bytearray()
|
||||
for page in range(_MAX_FILE_PAGES):
|
||||
f = self._exchange(SUB_FILE_READ_NEXT,
|
||||
params=_FILE_FIRST_PAGE_PARAMS if page == 0 else bytes(10))
|
||||
if page == 0:
|
||||
continue # the descriptor
|
||||
if not any(f.data):
|
||||
return bytes(body)
|
||||
body += f.data[11:]
|
||||
raise ProtocolError(f"{path}: no end of file after {_MAX_FILE_PAGES} pages")
|
||||
|
||||
# ── Event chain ───────────────────────────────────────────────────────────
|
||||
|
||||
def arm_event(self) -> MicromateFrame:
|
||||
|
||||
@@ -0,0 +1,75 @@
|
||||
"""schedule.py -- a Micromate's schedule file, parsed. Pure; read-only by design.
|
||||
|
||||
THOR's scheduler lives in a file on the unit, `\\system\\schedule\\schedule.dat`,
|
||||
read by path (`MicromateProtocol.read_file`). The format is decoded in
|
||||
docs/micromate_protocol_reference.md, *The schedule record format* (measured on
|
||||
UM12947, 2026-09-24/25): 260-byte records,
|
||||
|
||||
[0] record 0 only: 3 = repeat on, 2 = repeat off
|
||||
[4] half-hour slot, 0-47
|
||||
[5] day (3 in every record seen -- undetermined)
|
||||
[6] action bitmask: 2 start monitoring with setup, 4 stop, 8 self-check,
|
||||
16 auto call home
|
||||
[7] setup-name length
|
||||
[8:260] setup name (empty for actions that take none)
|
||||
|
||||
Why SFM reads it (phase 5): each scheduled start LOADS the setup it names. A
|
||||
settings change to any other setup would be replaced at the next start, so SFM
|
||||
refuses that change -- `schedule_conflicts`. SFM never writes the schedule.
|
||||
"""
|
||||
from __future__ import annotations
|
||||
|
||||
from dataclasses import dataclass
|
||||
from typing import List, Tuple
|
||||
|
||||
SCHEDULE_PATH = "\\system\\schedule\\schedule.dat"
|
||||
|
||||
_RECORD = 260
|
||||
_NAME_MAX = _RECORD - 8
|
||||
_ACTIONS = ((0x02, "start_with_setup"), (0x04, "stop"), (0x08, "self_check"), (0x10, "call_home"))
|
||||
_KNOWN_BITS = sum(bit for bit, _ in _ACTIONS)
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class ScheduleEntry:
|
||||
index: int
|
||||
time: str # "HH:MM", from the half-hour slot
|
||||
day: int # the raw byte; undetermined
|
||||
action_bits: int
|
||||
actions: Tuple[str, ...] # named bits; any other set bit as "unknown(0xNN)"
|
||||
setup: str # "" when the action takes no setup
|
||||
|
||||
|
||||
def _actions(bits: int) -> Tuple[str, ...]:
|
||||
named = tuple(name for bit, name in _ACTIONS if bits & bit)
|
||||
unknown = tuple(f"unknown(0x{1 << i:02x})" for i in range(8)
|
||||
if bits & (1 << i) and not (1 << i) & _KNOWN_BITS)
|
||||
return named + unknown
|
||||
|
||||
|
||||
def parse_schedule(body: bytes) -> List[ScheduleEntry]:
|
||||
"""The entries in a schedule file body. A record with nothing in [4:8] and
|
||||
no name ends the list (the file is padded with zeros)."""
|
||||
out: List[ScheduleEntry] = []
|
||||
for i in range(len(body) // _RECORD):
|
||||
r = body[i * _RECORD:(i + 1) * _RECORD]
|
||||
n = min(r[7], _NAME_MAX)
|
||||
name = r[8:8 + n].decode("ascii", "replace") if n else ""
|
||||
if not any(r[4:8]) and not name:
|
||||
break
|
||||
slot = r[4]
|
||||
out.append(ScheduleEntry(index=i, time=f"{slot // 2:02d}:{(slot % 2) * 30:02d}", day=r[5],
|
||||
action_bits=r[6], actions=_actions(r[6]), setup=name))
|
||||
return out
|
||||
|
||||
|
||||
def _same_setup(a: str, b: str) -> bool:
|
||||
return a.strip().casefold() == b.strip().casefold()
|
||||
|
||||
|
||||
def schedule_conflicts(entries: List[ScheduleEntry], active_setup: str) -> List[ScheduleEntry]:
|
||||
"""The scheduled starts that would load a setup other than `active_setup`
|
||||
(compared ignoring case and surrounding spaces: THOR and the keypad disagree
|
||||
on case, e.g. `factory.MMB` / `test2.mmb`)."""
|
||||
return [e for e in entries
|
||||
if "start_with_setup" in e.actions and e.setup and not _same_setup(e.setup, active_setup)]
|
||||
@@ -88,6 +88,20 @@ def crc_ok(content: bytes) -> bool:
|
||||
return _crc16_aug_ccitt(content[: n - 2]) == int.from_bytes(content[n : n + 2], "big")
|
||||
|
||||
|
||||
def with_crc(content: bytes) -> bytes:
|
||||
"""`content` with its trailing checksum recomputed: CRC-16/AUG-CCITT over
|
||||
``[0:N-2]``, stored big-endian at ``[N:N+2]`` (the rule `crc_ok` checks).
|
||||
THOR's write omits the checksum and the unit computes its own; this keeps a
|
||||
patched block self-consistent so a plan's integrity check still means
|
||||
something."""
|
||||
n = int.from_bytes(content[0:2], "big")
|
||||
if n < 2 or len(content) < n + 2:
|
||||
raise ValueError(f"block header says {n} but the block is {len(content)} B")
|
||||
out = bytearray(content)
|
||||
out[n : n + 2] = _crc16_aug_ccitt(content[: n - 2]).to_bytes(2, "big")
|
||||
return bytes(out)
|
||||
|
||||
|
||||
def _f32(c: bytes, offset: int) -> float:
|
||||
return struct.unpack_from(">f", c, offset)[0]
|
||||
|
||||
|
||||
@@ -0,0 +1,439 @@
|
||||
"""setup_fields.py -- the settings an operator can change, for both series (phase 5).
|
||||
|
||||
Pure byte interpretation: no I/O, no device, no `sfm` and no `minimateplus`
|
||||
imports. Every offset is into the settings block's CONTENT:
|
||||
|
||||
* Series 4: the `0x1A` content, 2,092 bytes (N = 2090, then its CRC).
|
||||
* Series 3: the 1A read assembled by `minimateplus.protocol.
|
||||
assemble_compliance_content`, 2,090 bytes (N = 2090, no CRC in the read).
|
||||
|
||||
**One layout.** Measured 2026-11-03: Blastware's MiniMate compliance image IS
|
||||
Series IV's `0x1A` content layout (`decode_setup` reads it), and each of
|
||||
BE11529's nine 2026-04-20 Blastware writes moved exactly the bytes of the field
|
||||
it changed. Series 4's offsets are from the 47-snapshot keypad pass on UM20147
|
||||
(2026-10-17/19). Fields measured on one series only are offered on that series
|
||||
only.
|
||||
|
||||
**Limits are the units' own, from Instantel's manuals** (Brian, 2026-11-03: "I
|
||||
want to use the actual unit limits, not just what we have done in the past"):
|
||||
* geophone trigger 0.005-10 in/s in steps of 0.001 -- MiniMate Plus manual
|
||||
716U0101 Rev 15, Appendix *Series III Specifications*; Micromate manual
|
||||
721U0201 Rev 06, *Geophone Trigger Level* -- and at most the range's full
|
||||
scale;
|
||||
* record time: Micromate 1-90 s (*Record Time*); MiniMate up to §4.4's
|
||||
*Maximum Record Times* for a 1 MB unit, channels 1-4, at the sample rate,
|
||||
and 13 s in Histogram Combo (§3.8.9);
|
||||
* job number 1-9999 (both manuals).
|
||||
What a unit does not take, the read-back shows (`settings_state`).
|
||||
|
||||
tests/test_setup_fields.py holds this to Blastware's writes and the keypad
|
||||
fixtures byte for byte.
|
||||
"""
|
||||
from __future__ import annotations
|
||||
|
||||
import hashlib
|
||||
import math
|
||||
import struct
|
||||
from typing import Any, Dict, List, Optional, Set
|
||||
|
||||
from .setup_block import crc_ok, with_crc
|
||||
|
||||
|
||||
class SettingsValueError(ValueError):
|
||||
"""A requested change SFM will not make, said plainly. Nothing is sent."""
|
||||
|
||||
|
||||
# ── Layout ──────────────────────────────────────────────────────────────────
|
||||
|
||||
_MODE = 5
|
||||
_SAMPLE_RATE = slice(6, 8) # u16 BE
|
||||
_HIST_INTERVAL = slice(8, 10) # u16 BE seconds
|
||||
_RECORD_TIME = 18 # f32 BE seconds
|
||||
_REPORT_FLAGS = 39 # bit 0x02 = job number on the report (measured both series)
|
||||
_JOB_SHOWN = 0x02
|
||||
_JOB_NUMBER = slice(40, 42) # u16 BE
|
||||
|
||||
_NOTE_LABEL, _NOTE_VALUE, _NOTE_STRIDE, _NOTES = 122, 144, 64, 4
|
||||
_NOTE_LABEL_WIDTH, _NOTE_WIDTH = 22, 42
|
||||
NOTE_MAX = _NOTE_WIDTH - 1 # a NUL always ends the value
|
||||
|
||||
_CHANNELS, _CHANNEL_SIZE, _GEOPHONES = 1708, 48, (0, 1, 2)
|
||||
_CH_RANGE = 29 # u8: 0 Normal (10 in/s), 1 Sensitive (1.25 in/s) -- Series 3, measured
|
||||
_CH_TRIGGER = 30 # f32 BE, in/s for a geophone
|
||||
_CH_UNIT = slice(34, 38) # "in." / "in" (the keypad re-renders it); NOT an identifier
|
||||
_CH_ALARM = 38 # f32 BE -- Series 3; write measured at the bench 2026-11-04
|
||||
_FULL_SCALE = {0: 10.0, 1: 1.25}
|
||||
_RANGES = {"normal": 0, "sensitive": 1}
|
||||
|
||||
# Blastware writes these bytes as a fixed value on every write on record (11 of 11,
|
||||
# both units); the unit reads `01 7f` there after a monitoring session. Meaning
|
||||
# unknown -- SFM writes what Blastware writes. Series 3 only.
|
||||
S3_BLASTWARE_FIXED = {26: b"\x00\x00"}
|
||||
|
||||
# Measured at the bench 2026-11-04 (BE9441, Brian's go): 1.0 -> 1.5 -> 1.0 in/s,
|
||||
# each acknowledged, read back, and shown in the unit's own setup menu; the write
|
||||
# moved exactly channel +39 of the three geophones (the f32 at +38).
|
||||
S3_ALARM_WRITE_MEASURED = True
|
||||
|
||||
MODES = {
|
||||
3: {"single_shot": 0x00, "continuous": 0x01, "histogram": 0x03, "histogram_continuous": 0x04},
|
||||
4: {"waveform": 0x01, "manual": 0x02, "histogram": 0x03, "combo": 0x04},
|
||||
}
|
||||
_MODE_LABELS = {
|
||||
"single_shot": "Single Shot", "continuous": "Continuous", "histogram": "Histogram",
|
||||
"histogram_continuous": "Histogram + Continuous", "waveform": "Waveform", "manual": "Manual",
|
||||
"combo": "Combo",
|
||||
}
|
||||
SAMPLE_RATES = (1024, 2048, 4096)
|
||||
INTERVALS = (2, 5, 15, 60, 300, 900)
|
||||
TRIGGER_MIN, TRIGGER_MAX, TRIGGER_STEP = 0.005, 10.0, 0.001
|
||||
RECORD_MIN_S = 1.0
|
||||
S4_MAX_RECORD_S = 90.0
|
||||
S3_MAX_RECORD_S = {1024: 104.0, 2048: 52.0, 4096: 26.0}
|
||||
S3_COMBO_MAX_RECORD_S = 13.0
|
||||
JOB_MIN, JOB_MAX = 1, 9999
|
||||
|
||||
_SERIES_FIELDS = {
|
||||
3: ("record_mode", "sample_rate", "histogram_interval_s", "record_time_s", "geo_trigger_ips",
|
||||
"geo_range", "geo_alarm_ips", "job_number", "job_number_shown",
|
||||
"note_1", "note_2", "note_3", "note_4"),
|
||||
4: ("record_mode", "sample_rate", "histogram_interval_s", "record_time_s", "geo_trigger_ips",
|
||||
"job_number", "job_number_shown", "note_1", "note_2", "note_3", "note_4"),
|
||||
}
|
||||
_LEVELS = ("geo_trigger_ips", "geo_alarm_ips")
|
||||
|
||||
|
||||
def _ch(k: int) -> int:
|
||||
return _CHANNELS + _CHANNEL_SIZE * k
|
||||
|
||||
|
||||
def _f32(c: bytes, offset: int) -> float:
|
||||
return struct.unpack_from(">f", c, offset)[0]
|
||||
|
||||
|
||||
def _shown(v: float) -> float:
|
||||
"""An f32 as an operator typed it: 0.30000001192 is 0.3."""
|
||||
return round(v, 6)
|
||||
|
||||
|
||||
def _note_offsets(n: int) -> tuple:
|
||||
label = _NOTE_LABEL + n * _NOTE_STRIDE
|
||||
value = _NOTE_VALUE + n * _NOTE_STRIDE
|
||||
return label, value
|
||||
|
||||
|
||||
def _note_label(c: bytes, n: int) -> str:
|
||||
start, _ = _note_offsets(n)
|
||||
raw = c[start:start + _NOTE_LABEL_WIDTH].split(b"\x00")[0]
|
||||
text = raw.decode("ascii", "replace").strip().rstrip(":").strip()
|
||||
return text or f"Note {n + 1}"
|
||||
|
||||
|
||||
def _note_value(c: bytes, n: int) -> str:
|
||||
_, start = _note_offsets(n)
|
||||
return c[start:start + _NOTE_WIDTH].split(b"\x00")[0].decode("ascii", "replace")
|
||||
|
||||
|
||||
def field_bytes(series: int) -> Dict[str, Set[int]]:
|
||||
"""Every byte each field may move, by content offset."""
|
||||
def chans(rel: int, width: int) -> Set[int]:
|
||||
return {_ch(k) + rel + i for k in _GEOPHONES for i in range(width)}
|
||||
out = {
|
||||
"record_mode": {_MODE},
|
||||
"sample_rate": set(range(6, 8)),
|
||||
"histogram_interval_s": set(range(8, 10)),
|
||||
"record_time_s": set(range(_RECORD_TIME, _RECORD_TIME + 4)),
|
||||
"geo_trigger_ips": chans(_CH_TRIGGER, 4),
|
||||
"geo_range": chans(_CH_RANGE, 1),
|
||||
"geo_alarm_ips": chans(_CH_ALARM, 4),
|
||||
"job_number": set(range(40, 42)),
|
||||
"job_number_shown": {_REPORT_FLAGS},
|
||||
}
|
||||
for n in range(_NOTES):
|
||||
_, v = _note_offsets(n)
|
||||
out[f"note_{n + 1}"] = set(range(v, v + _NOTE_WIDTH))
|
||||
return {f: out[f] for f in _SERIES_FIELDS[series]}
|
||||
|
||||
|
||||
# ── Reading ─────────────────────────────────────────────────────────────────
|
||||
|
||||
def _mode_name(c: bytes, series: int) -> str:
|
||||
code = c[_MODE]
|
||||
for name, value in MODES[series].items():
|
||||
if value == code:
|
||||
return name
|
||||
return f"unknown(0x{code:02x})"
|
||||
|
||||
|
||||
def _range_code(c: bytes) -> int:
|
||||
return c[_ch(0) + _CH_RANGE]
|
||||
|
||||
|
||||
def _full_scale(c: bytes, series: int, range_name: Optional[str] = None) -> Optional[float]:
|
||||
if series == 4:
|
||||
return _FULL_SCALE[0] # Series 4's range byte is not mapped; 10 in/s is the hardware's
|
||||
code = _RANGES[range_name] if range_name is not None else _range_code(c)
|
||||
return _FULL_SCALE.get(code)
|
||||
|
||||
|
||||
def _s3_max_record(rate: int, mode: str) -> Optional[float]:
|
||||
top = S3_MAX_RECORD_S.get(rate)
|
||||
if top is None:
|
||||
return None
|
||||
return min(top, S3_COMBO_MAX_RECORD_S) if mode == "histogram_continuous" else top
|
||||
|
||||
|
||||
def _unit_string(c: bytes) -> List[str]:
|
||||
return [c[_ch(k) + _CH_UNIT.start:_ch(k) + _CH_UNIT.stop].replace(b"\x00", b"")
|
||||
.replace(b".", b"").decode("ascii", "replace") for k in _GEOPHONES]
|
||||
|
||||
|
||||
def editable_fields(content: bytes, series: int) -> List[Dict[str, Any]]:
|
||||
"""The fields an operator can change, described for a form: field, label,
|
||||
kind ("number" / "choice" / "text" / "bool"), value, and as relevant unit,
|
||||
min, max, step, choices [{value, label}], maxlength, readonly."""
|
||||
c = content
|
||||
rate = int.from_bytes(c[_SAMPLE_RATE], "big")
|
||||
mode = _mode_name(c, series)
|
||||
out: List[Dict[str, Any]] = [
|
||||
{"field": "record_mode", "label": "Record mode", "kind": "choice", "value": mode,
|
||||
"choices": [{"value": n, "label": _MODE_LABELS[n]} for n in MODES[series]]},
|
||||
{"field": "sample_rate", "label": "Sample rate", "kind": "choice", "value": rate, "unit": "sps",
|
||||
"choices": [{"value": r, "label": f"{r} sps"} for r in SAMPLE_RATES]},
|
||||
{"field": "histogram_interval_s", "label": "Histogram interval", "kind": "choice",
|
||||
"value": int.from_bytes(c[_HIST_INTERVAL], "big"),
|
||||
"choices": [{"value": s, "label": f"{s} s" if s < 60 else f"{s // 60} min"} for s in INTERVALS]},
|
||||
{"field": "record_time_s", "label": "Record time", "kind": "number", "unit": "s",
|
||||
"value": _shown(_f32(c, _RECORD_TIME)), "min": RECORD_MIN_S,
|
||||
"max": S4_MAX_RECORD_S if series == 4 else _s3_max_record(rate, mode)},
|
||||
{"field": "geo_trigger_ips", "label": "Geophone trigger", "kind": "number", "unit": "in/s",
|
||||
"value": _shown(_f32(c, _ch(0) + _CH_TRIGGER)), "min": TRIGGER_MIN,
|
||||
"max": min(TRIGGER_MAX, _full_scale(c, series) or TRIGGER_MAX), "step": TRIGGER_STEP},
|
||||
]
|
||||
if series == 3:
|
||||
code = _range_code(c)
|
||||
name = next((n for n, v in _RANGES.items() if v == code), f"unknown(0x{code:02x})")
|
||||
out.append({"field": "geo_range", "label": "Geophone range", "kind": "choice", "value": name,
|
||||
"choices": [{"value": "normal", "label": "Normal (10 in/s)"},
|
||||
{"value": "sensitive", "label": "Sensitive (1.25 in/s)"}]})
|
||||
out.append({"field": "geo_alarm_ips", "label": "Geophone alarm", "kind": "number",
|
||||
"unit": "in/s", "value": _shown(_f32(c, _ch(0) + _CH_ALARM)),
|
||||
"min": TRIGGER_MIN, "max": _full_scale(c, 3) or TRIGGER_MAX,
|
||||
"step": TRIGGER_STEP, "readonly": not S3_ALARM_WRITE_MEASURED})
|
||||
out.append({"field": "job_number", "label": "Job number", "kind": "number",
|
||||
"value": int.from_bytes(c[_JOB_NUMBER], "big"), "min": JOB_MIN, "max": JOB_MAX, "step": 1})
|
||||
out.append({"field": "job_number_shown", "label": "Job number on report", "kind": "bool",
|
||||
"value": bool(c[_REPORT_FLAGS] & _JOB_SHOWN)})
|
||||
for n in range(_NOTES):
|
||||
out.append({"field": f"note_{n + 1}", "label": _note_label(c, n), "kind": "text",
|
||||
"value": _note_value(c, n), "maxlength": NOTE_MAX})
|
||||
return out
|
||||
|
||||
|
||||
def field_values(content: bytes, series: int) -> Dict[str, Any]:
|
||||
return {d["field"]: d["value"] for d in editable_fields(content, series)}
|
||||
|
||||
|
||||
def field_rows(before: bytes, written: bytes, series: int, fields, now: Optional[bytes] = None) -> Dict[str, Dict[str, Any]]:
|
||||
"""For each changed field: its label, the value the unit had (old), the value
|
||||
sent (new) and, given a read-back, what the unit now holds (now)."""
|
||||
a, w = field_values(before, series), field_values(written, series)
|
||||
n = field_values(now, series) if now is not None else None
|
||||
labels = {d["field"]: d["label"] for d in editable_fields(written, series)}
|
||||
out: Dict[str, Dict[str, Any]] = {}
|
||||
for f in fields:
|
||||
row: Dict[str, Any] = {"label": labels[f], "old": a[f], "new": w[f]}
|
||||
if n is not None:
|
||||
row["now"] = n[f]
|
||||
out[f] = row
|
||||
return out
|
||||
|
||||
|
||||
# ── Checking ────────────────────────────────────────────────────────────────
|
||||
|
||||
def _number(field: str, v: Any) -> float:
|
||||
if isinstance(v, bool) or not isinstance(v, (int, float)) or not math.isfinite(v):
|
||||
raise SettingsValueError(f"{field} must be a number, not {v!r}")
|
||||
return float(v)
|
||||
|
||||
|
||||
def _integer(field: str, v: Any) -> int:
|
||||
if isinstance(v, bool) or not isinstance(v, int):
|
||||
raise SettingsValueError(f"{field} must be a whole number, not {v!r}")
|
||||
return v
|
||||
|
||||
|
||||
def check_changes(content: bytes, series: int, changes: Dict[str, Any]) -> Dict[str, Any]:
|
||||
"""The changes, normalised -- or SettingsValueError naming the first one SFM
|
||||
will not make, and why. Checks names, types and the units' own limits, then
|
||||
what depends on this unit's block: its unit strings and its range."""
|
||||
if series not in _SERIES_FIELDS:
|
||||
raise SettingsValueError(f"Series {series} has no settings SFM can change")
|
||||
if not isinstance(changes, dict) or not changes:
|
||||
raise SettingsValueError("no settings to change")
|
||||
allowed = _SERIES_FIELDS[series]
|
||||
out: Dict[str, Any] = {}
|
||||
for field, v in changes.items():
|
||||
if field not in allowed:
|
||||
raise SettingsValueError(f"{field} is not a setting SFM can change on a Series {series} unit")
|
||||
if field == "record_mode":
|
||||
if v not in MODES[series]:
|
||||
raise SettingsValueError(f"record_mode must be one of {', '.join(MODES[series])}, not {v!r}")
|
||||
out[field] = v
|
||||
elif field == "sample_rate":
|
||||
if _integer(field, v) not in SAMPLE_RATES:
|
||||
raise SettingsValueError(f"sample_rate must be one of {SAMPLE_RATES}, not {v}")
|
||||
out[field] = v
|
||||
elif field == "histogram_interval_s":
|
||||
if _integer(field, v) not in INTERVALS:
|
||||
raise SettingsValueError(f"histogram_interval_s must be one of {INTERVALS} s, not {v}")
|
||||
out[field] = v
|
||||
elif field == "geo_range":
|
||||
if v not in _RANGES:
|
||||
raise SettingsValueError(f"geo_range must be normal or sensitive, not {v!r}")
|
||||
out[field] = v
|
||||
elif field in ("geo_trigger_ips", "geo_alarm_ips"):
|
||||
if field == "geo_alarm_ips" and not S3_ALARM_WRITE_MEASURED:
|
||||
raise SettingsValueError("the alarm level is shown but not changed yet: a MiniMate "
|
||||
"alarm write has never been measured (the bench measures it)")
|
||||
x = _number(field, v)
|
||||
if not TRIGGER_MIN <= x <= TRIGGER_MAX:
|
||||
raise SettingsValueError(f"{field} must be {TRIGGER_MIN}-{TRIGGER_MAX} in/s, not {x}")
|
||||
if abs(x - round(x, 3)) > 1e-9:
|
||||
raise SettingsValueError(f"{field} must be in steps of {TRIGGER_STEP} in/s, not {x}")
|
||||
out[field] = round(x, 3)
|
||||
elif field == "record_time_s":
|
||||
out[field] = _number(field, v)
|
||||
elif field == "job_number":
|
||||
if not JOB_MIN <= _integer(field, v) <= JOB_MAX:
|
||||
raise SettingsValueError(f"job_number must be {JOB_MIN}-{JOB_MAX}, not {v}")
|
||||
out[field] = v
|
||||
elif field == "job_number_shown":
|
||||
if not isinstance(v, bool):
|
||||
raise SettingsValueError(f"job_number_shown must be true or false, not {v!r}")
|
||||
out[field] = v
|
||||
else: # note_1 .. note_4
|
||||
if not isinstance(v, str):
|
||||
raise SettingsValueError(f"{field} must be text, not {v!r}")
|
||||
if any(not 0x20 <= ord(ch) <= 0x7E for ch in v):
|
||||
raise SettingsValueError(f"{field} must be plain printable ASCII (no accents, tabs or "
|
||||
"line breaks)")
|
||||
if len(v) > NOTE_MAX:
|
||||
raise SettingsValueError(f"{field} is {len(v)} characters; the unit holds {NOTE_MAX}")
|
||||
out[field] = v
|
||||
|
||||
# What depends on this unit's block, with the NEW mode / rate / range if they change
|
||||
# too -- checked on the block that would RESULT, so a one-field change (the range,
|
||||
# the rate, the mode) cannot leave a value the unit already holds over its limit
|
||||
# (final review, 2026-11-03).
|
||||
c = content
|
||||
if any(f in out for f in ("record_time_s", "sample_rate", "record_mode")):
|
||||
t = out.get("record_time_s", _shown(_f32(c, _RECORD_TIME)))
|
||||
held = "" if "record_time_s" in out else f" (the unit holds {t:g} s; change the record time too)"
|
||||
if series == 4:
|
||||
top: Optional[float] = S4_MAX_RECORD_S
|
||||
else:
|
||||
rate = out.get("sample_rate", int.from_bytes(c[_SAMPLE_RATE], "big"))
|
||||
top = _s3_max_record(rate, out.get("record_mode", _mode_name(c, series)))
|
||||
if top is None:
|
||||
raise SettingsValueError(f"this unit's sample rate ({rate}) has no record-time limit "
|
||||
"in the manual -- set the sample rate too")
|
||||
if not RECORD_MIN_S <= t <= top:
|
||||
raise SettingsValueError(f"record_time_s must be {RECORD_MIN_S}-{top:g} s here, not {t}{held}")
|
||||
if any(f in out for f in (*_LEVELS, "geo_range")):
|
||||
units = _unit_string(c)
|
||||
if any(u != "in" for u in units):
|
||||
raise SettingsValueError(f"this unit's geophone channels read {units}, not in/s -- only "
|
||||
"in/s is measured, so SFM will not change a level or the range")
|
||||
full = _full_scale(c, series, out.get("geo_range"))
|
||||
if full is None:
|
||||
raise SettingsValueError("this unit's geophone range byte is not a value ever measured")
|
||||
held_levels = {"geo_trigger_ips": _CH_TRIGGER, "geo_alarm_ips": _CH_ALARM}
|
||||
for f in _LEVELS:
|
||||
if f not in _SERIES_FIELDS[series]:
|
||||
continue
|
||||
v = out.get(f, _shown(_f32(c, _ch(0) + held_levels[f])))
|
||||
if v > full:
|
||||
held = "" if f in out else " (the unit holds it)"
|
||||
raise SettingsValueError(f"{f} {v} in/s is above the range's full scale ({full} in/s){held}")
|
||||
return out
|
||||
|
||||
|
||||
# ── Writing ─────────────────────────────────────────────────────────────────
|
||||
|
||||
def encode_setup(content: bytes, series: int, changes: Dict[str, Any]) -> bytes:
|
||||
"""`content` with only the changed fields' bytes moved. `changes` should
|
||||
come from check_changes; this patches, it does not judge. Bit fields are
|
||||
patched bit by bit. Series 3 also writes Blastware's fixed bytes; Series 4
|
||||
gets its checksum recomputed."""
|
||||
out = bytearray(content)
|
||||
for field, v in changes.items():
|
||||
if field == "record_mode":
|
||||
out[_MODE] = MODES[series][v]
|
||||
elif field == "sample_rate":
|
||||
out[_SAMPLE_RATE] = int(v).to_bytes(2, "big")
|
||||
elif field == "histogram_interval_s":
|
||||
out[_HIST_INTERVAL] = int(v).to_bytes(2, "big")
|
||||
elif field == "record_time_s":
|
||||
struct.pack_into(">f", out, _RECORD_TIME, float(v))
|
||||
elif field == "geo_trigger_ips":
|
||||
for k in _GEOPHONES:
|
||||
struct.pack_into(">f", out, _ch(k) + _CH_TRIGGER, float(v))
|
||||
elif field == "geo_alarm_ips":
|
||||
for k in _GEOPHONES:
|
||||
struct.pack_into(">f", out, _ch(k) + _CH_ALARM, float(v))
|
||||
elif field == "geo_range":
|
||||
for k in _GEOPHONES:
|
||||
out[_ch(k) + _CH_RANGE] = _RANGES[v]
|
||||
elif field == "job_number":
|
||||
out[_JOB_NUMBER] = int(v).to_bytes(2, "big")
|
||||
elif field == "job_number_shown":
|
||||
out[_REPORT_FLAGS] = (out[_REPORT_FLAGS] | _JOB_SHOWN) if v else (out[_REPORT_FLAGS] & ~_JOB_SHOWN)
|
||||
elif field.startswith("note_") and field[5:].isdigit() and 1 <= int(field[5:]) <= _NOTES:
|
||||
_, start = _note_offsets(int(field[5:]) - 1)
|
||||
out[start:start + _NOTE_WIDTH] = v.encode("ascii").ljust(_NOTE_WIDTH, b"\x00")
|
||||
else:
|
||||
raise SettingsValueError(f"{field} is not a setting SFM can change")
|
||||
if series == 3:
|
||||
for offset, value in S3_BLASTWARE_FIXED.items():
|
||||
out[offset:offset + len(value)] = value
|
||||
return bytes(out)
|
||||
return with_crc(bytes(out))
|
||||
|
||||
|
||||
# ── Reading back ────────────────────────────────────────────────────────────
|
||||
|
||||
_COMPARED = 2090
|
||||
|
||||
|
||||
def settings_state(before: bytes, written: bytes, now: bytes, *, series: int) -> str:
|
||||
"""What a read of the unit says about a change, from the bytes alone:
|
||||
"as asked" (it holds what was written), "unchanged" (it holds what it had),
|
||||
or "differs". Floats are never compared -- 0.3 is the same f32 both ways.
|
||||
Series 4 also needs the unit's own checksum to hold. Series 3 bytes that
|
||||
differ only in Blastware's fixed bytes count as as asked: nothing the operator
|
||||
asked for is different."""
|
||||
a, w, n = before[:_COMPARED], written[:_COMPARED], now[:_COMPARED]
|
||||
if series == 4 and not crc_ok(now):
|
||||
return "differs"
|
||||
if n == w:
|
||||
return "as asked"
|
||||
if series == 3:
|
||||
fixed = {o + i for o, v in S3_BLASTWARE_FIXED.items() for i in range(len(v))}
|
||||
if len(n) == len(w) and all(n[i] == w[i] for i in range(len(n)) if i not in fixed):
|
||||
return "as asked"
|
||||
if n == a:
|
||||
return "unchanged"
|
||||
return "differs"
|
||||
|
||||
|
||||
def revision(blocks: List[bytes]) -> str:
|
||||
"""A short fingerprint of the blocks a preview read; a live change must match it."""
|
||||
return hashlib.sha256(b"".join(bytes(b) for b in blocks)).hexdigest()[:16]
|
||||
|
||||
|
||||
def changes_bytes(changes: Dict[str, Any]) -> bytes:
|
||||
"""The normalised changes, canonically: part of a preview's revision, so a live
|
||||
change must ask for exactly what was previewed (final review, 2026-11-03)."""
|
||||
import json
|
||||
return json.dumps(changes, sort_keys=True, separators=(",", ":")).encode("ascii")
|
||||
+9
-6
@@ -22,6 +22,7 @@ from .opcodes import CROSS_SERIES_COLLISIONS, WRITE_SUBS, OpcodeRefused
|
||||
from .setup_block import crc_ok
|
||||
|
||||
_CONFIRM = 0xFFFF
|
||||
_CALL_HOME_OBSERVED = (0x00, 0x01, 0x04, 0x05) # content[5] values units have held
|
||||
|
||||
# block content sizes THOR's offsets were observed at (all on UM12947 / 11.0CB)
|
||||
_PREFS_LEN, _TRIGGER_LEN, _SETUP_LEN, _CALL_HOME_LEN = 90, 28, 2092, 126
|
||||
@@ -113,9 +114,10 @@ def plan_call_home_enabled(call_home: bytes, enabled: bool) -> WritePlan:
|
||||
|
||||
Bit 0 of `[5]` is the enable. 🔶 UM12947 (THOR's unit) read 0x05 enabled /
|
||||
0x04 disabled, bit 2 set in both; UM20147 reads 0x01 (measured, phase-2 dry
|
||||
run). So on UM20147 "off" writes 0x00, a value no capture shows being
|
||||
written: the target value there is unobserved, and the plan's `warnings`
|
||||
say so. `[118:120]` is unit-maintained and THOR echoes it.
|
||||
run). So on UM20147 "off" writes 0x00 -- measured at the bench 2026-11-03
|
||||
(and again 11-04): 0x01 <-> 0x00 acknowledged, read back, and matched in the
|
||||
unit's own menu. A value outside those four still carries a warning.
|
||||
`[118:120]` is unit-maintained and THOR echoes it.
|
||||
"""
|
||||
if len(call_home) != _CALL_HOME_LEN:
|
||||
raise ValueError(f"call-home content must be {_CALL_HOME_LEN} B "
|
||||
@@ -128,9 +130,10 @@ def plan_call_home_enabled(call_home: bytes, enabled: bool) -> WritePlan:
|
||||
what = "call-home " + ("enable" if enabled else "disable")
|
||||
start = call_home[5]
|
||||
warnings = []
|
||||
if start not in (0x04, 0x05) or b5 not in (0x04, 0x05):
|
||||
warnings.append(f"content[5] 0x{start:02X} -> 0x{b5:02X}: THOR was only ever "
|
||||
"seen writing 0x04/0x05 (UM12947); this value is unobserved")
|
||||
if start not in _CALL_HOME_OBSERVED or b5 not in _CALL_HOME_OBSERVED:
|
||||
warnings.append(f"content[5] 0x{start:02X} -> 0x{b5:02X}: no unit has been seen "
|
||||
"holding this value (0x04/0x05 UM12947 by THOR, 0x00/0x01 UM20147 "
|
||||
"by SFM); it is unobserved")
|
||||
if b5 == start:
|
||||
warnings.append(f"the unit is already call-home {'enabled' if enabled else 'disabled'}"
|
||||
" -- this write changes nothing")
|
||||
|
||||
+33
-376
@@ -70,15 +70,8 @@ S3_MONITORING_FLAGS = frozenset({0x10, 0x0B})
|
||||
# ⚠ RETRACTED 2026-10-27 (#46): a trigger block "hardcoded from 3-11-26 -- no
|
||||
# read exists, Blastware writes this fixed blob". Blastware reads it first (SUB
|
||||
# 0x2E), and its byte 5 differs by unit and session (01 / 03 / 04 on record), so
|
||||
# the copy changed that setting on any unit that differed. apply_config reads
|
||||
# the unit's own block (MiniMateProtocol.read_trigger_config).
|
||||
|
||||
# Compliance ASCII slot format (confirmed from 3-11-26 capture + label search):
|
||||
# Each label occupies a 64-byte slot.
|
||||
# Value starts at slot_start + 22, max 42 bytes, null-padded.
|
||||
_COMPLIANCE_SLOT_SIZE = 64
|
||||
_COMPLIANCE_VALUE_OFFSET = 22
|
||||
_COMPLIANCE_VALUE_MAX = _COMPLIANCE_SLOT_SIZE - _COMPLIANCE_VALUE_OFFSET # 42
|
||||
# the copy changed that setting on any unit that differed. A settings write sends
|
||||
# the unit's own block back (sfm.device_access.s3 change_settings, phase 5).
|
||||
|
||||
|
||||
# ── MiniMateClient ────────────────────────────────────────────────────────────
|
||||
@@ -922,6 +915,8 @@ class MiniMateClient:
|
||||
compliance_data: bytes,
|
||||
trigger_data: bytes,
|
||||
waveform_data: bytes,
|
||||
*,
|
||||
escaped: bool = False,
|
||||
) -> None:
|
||||
"""
|
||||
Push a complete config update to the device using the confirmed write
|
||||
@@ -949,6 +944,10 @@ class MiniMateClient:
|
||||
trigger_data: Raw bytes for SUB 82 write (44-byte trigger config).
|
||||
waveform_data: Raw bytes for SUB 69 write.
|
||||
|
||||
`escaped`: False (the default) -- the blocks are logical, as every block
|
||||
read returns them since phase 5; True for blocks that still hold the
|
||||
parser's kept escape bytes.
|
||||
|
||||
Raises:
|
||||
RuntimeError: if the client is not connected.
|
||||
ProtocolError: if any write step fails (timeout, bad ack SUB).
|
||||
@@ -960,32 +959,36 @@ class MiniMateClient:
|
||||
# 2026-10-27): a block refused after 68 + 73 had been sent left a partial
|
||||
# write behind. write_image is the same check each write makes.
|
||||
from .protocol import (SUB_COMPLIANCE_WRITE, SUB_EVENT_INDEX_WRITE,
|
||||
SUB_TRIGGER_CONFIG_WRITE, SUB_WAVEFORM_DATA_WRITE, write_image)
|
||||
SUB_TRIGGER_CONFIG_WRITE, SUB_WAVEFORM_DATA_WRITE, ImageRefused,
|
||||
write_image)
|
||||
for sub, data in ((SUB_EVENT_INDEX_WRITE, event_index_data),
|
||||
(SUB_COMPLIANCE_WRITE, compliance_data),
|
||||
(SUB_TRIGGER_CONFIG_WRITE, trigger_data),
|
||||
(SUB_WAVEFORM_DATA_WRITE, waveform_data)):
|
||||
write_image(sub, data)
|
||||
try:
|
||||
write_image(sub, data, escaped=escaped)
|
||||
except ValueError as exc: # refused before any frame: the caller audits "nothing sent"
|
||||
raise ImageRefused(str(exc)) from exc
|
||||
|
||||
# 68 → 73
|
||||
log.info("push_config_raw: write event index (SUB 68)")
|
||||
proto.write_event_index(event_index_data)
|
||||
proto.write_event_index(event_index_data, escaped=escaped)
|
||||
log.info("push_config_raw: confirm B (SUB 73)")
|
||||
proto.write_confirm(SUB_WRITE_CONFIRM_B)
|
||||
|
||||
# 71×3 → 72 (handled internally by write_compliance_config_raw)
|
||||
log.info("push_config_raw: write compliance config (SUB 71 ×3 + confirm 72)")
|
||||
proto.write_compliance_config_raw(compliance_data)
|
||||
proto.write_compliance_config_raw(compliance_data, escaped=escaped)
|
||||
|
||||
# 82 → 83
|
||||
log.info("push_config_raw: write trigger config (SUB 82)")
|
||||
proto.write_trigger_config(trigger_data)
|
||||
proto.write_trigger_config(trigger_data, escaped=escaped)
|
||||
log.info("push_config_raw: trigger confirm (SUB 83)")
|
||||
proto.write_confirm(SUB_TRIGGER_CONFIRM)
|
||||
|
||||
# 69 → 74 → 72
|
||||
log.info("push_config_raw: write waveform data (SUB 69)")
|
||||
proto.write_waveform_data(waveform_data)
|
||||
proto.write_waveform_data(waveform_data, escaped=escaped)
|
||||
log.info("push_config_raw: confirm C (SUB 74)")
|
||||
proto.write_confirm(SUB_WRITE_CONFIRM_C)
|
||||
log.info("push_config_raw: confirm A (SUB 72)")
|
||||
@@ -993,120 +996,6 @@ class MiniMateClient:
|
||||
|
||||
log.info("push_config_raw: complete")
|
||||
|
||||
def apply_config(
|
||||
self,
|
||||
*,
|
||||
# Recording parameters
|
||||
recording_mode: Optional[int] = None,
|
||||
sample_rate: Optional[int] = None,
|
||||
record_time: Optional[float] = None,
|
||||
histogram_interval_sec: Optional[int] = None,
|
||||
# Threshold parameters (geo channels, in/s)
|
||||
trigger_level_geo: Optional[float] = None,
|
||||
alarm_level_geo: Optional[float] = None,
|
||||
geo_range: Optional[int] = None, # 0x00=Normal 10in/s, 0x01=Sensitive 1.25in/s
|
||||
# Project / operator strings
|
||||
project: Optional[str] = None,
|
||||
client_name: Optional[str] = None,
|
||||
operator: Optional[str] = None,
|
||||
seis_loc: Optional[str] = None,
|
||||
notes: Optional[str] = None,
|
||||
) -> None:
|
||||
"""
|
||||
Read the current device config, apply any supplied changes to the
|
||||
compliance block, and write the full config back to the device.
|
||||
|
||||
Only non-None arguments are modified; all other bytes are round-tripped
|
||||
verbatim from the device.
|
||||
|
||||
Configurable fields
|
||||
-------------------
|
||||
Recording parameters:
|
||||
recording_mode : int — 0x00=Single Shot, 0x01=Continuous, 0x03=Histogram, 0x04=Histogram+Continuous
|
||||
sample_rate : int — samples/sec; valid values: 1024, 2048, 4096
|
||||
record_time : float — record duration in seconds (e.g. 2.0, 3.0)
|
||||
|
||||
Trigger/alarm thresholds and range (geo channels):
|
||||
trigger_level_geo : float — trigger threshold in/s (e.g. 0.5)
|
||||
alarm_level_geo : float — alarm threshold in/s (e.g. 1.0)
|
||||
geo_range : int — 0x00=Normal 10.000 in/s, 0x01=Sensitive 1.250 in/s
|
||||
(written to Tran/Vert/Long channel blocks)
|
||||
|
||||
Project / operator strings (max 41 ASCII characters each):
|
||||
project : str
|
||||
client_name : str
|
||||
operator : str
|
||||
seis_loc : str — sensor location
|
||||
notes : str — extended notes
|
||||
|
||||
Write sequence (confirmed from 3-11-26 BW TX capture):
|
||||
68→73 | 71×3→72 | 82→83 | 69→74→72
|
||||
|
||||
Write payloads:
|
||||
event_index_data : 88 bytes — read live via SUB 08
|
||||
compliance_data : ~2128 bytes — read live via SUB 1A (~2126 bytes, varies ±1-2) + \\x00\\x00 footer
|
||||
trigger_data : 26 bytes — read live via SUB 2E (was hard-coded; #46)
|
||||
waveform_data : 204 bytes — read live via SUB 09
|
||||
|
||||
Raises:
|
||||
RuntimeError: if not connected.
|
||||
ProtocolError: if any read or write step fails.
|
||||
ValueError: if compliance buffer is shorter than the 2082-byte write minimum.
|
||||
"""
|
||||
proto = self._require_proto()
|
||||
|
||||
# 1. Read current payloads from the device
|
||||
log.info("apply_config: reading event index (SUB 08)")
|
||||
event_index_data = proto.read_event_index()
|
||||
|
||||
log.info("apply_config: reading compliance config (SUB 1A)")
|
||||
compliance_raw = proto.read_compliance_config() # ~2126 bytes (varies ±1-2 by DLE jitter)
|
||||
|
||||
log.info("apply_config: reading waveform data (SUB 09)")
|
||||
waveform_data = proto.read_waveform_data_raw() # 204 bytes
|
||||
|
||||
log.info("apply_config: reading trigger config (SUB 2E)")
|
||||
trigger_data = proto.read_trigger_config() # 26 bytes, this unit's own
|
||||
|
||||
# 2. Patch the compliance buffer and build the 2128-byte write payload
|
||||
compliance_data = _encode_compliance_config(
|
||||
compliance_raw,
|
||||
recording_mode=recording_mode,
|
||||
sample_rate=sample_rate,
|
||||
record_time=record_time,
|
||||
histogram_interval_sec=histogram_interval_sec,
|
||||
trigger_level_geo=trigger_level_geo,
|
||||
alarm_level_geo=alarm_level_geo,
|
||||
geo_range=geo_range,
|
||||
project=project,
|
||||
client_name=client_name,
|
||||
operator=operator,
|
||||
seis_loc=seis_loc,
|
||||
notes=notes,
|
||||
)
|
||||
log.info("apply_config: compliance payload ready (%d bytes)", len(compliance_data))
|
||||
|
||||
# 3. Push the full write sequence to the device
|
||||
self.push_config_raw(event_index_data, compliance_data, trigger_data, waveform_data)
|
||||
log.info("apply_config: complete")
|
||||
|
||||
def set_project_info(
|
||||
self,
|
||||
project: Optional[str] = None,
|
||||
client_name: Optional[str] = None,
|
||||
operator: Optional[str] = None,
|
||||
seis_loc: Optional[str] = None,
|
||||
notes: Optional[str] = None,
|
||||
) -> None:
|
||||
"""Backwards-compat shim — delegates to apply_config()."""
|
||||
self.apply_config(
|
||||
project=project,
|
||||
client_name=client_name,
|
||||
operator=operator,
|
||||
seis_loc=seis_loc,
|
||||
notes=notes,
|
||||
)
|
||||
|
||||
# ── Call home config ──────────────────────────────────────────────────────
|
||||
|
||||
def get_call_home_config(self) -> CallHomeConfig:
|
||||
@@ -1132,6 +1021,21 @@ class MiniMateClient:
|
||||
read-modify-write (`call_home_image`)."""
|
||||
return self._require_proto().read_call_home_config()
|
||||
|
||||
def read_compliance_content(self) -> bytes:
|
||||
"""The 1A settings read as the logical 2,090-byte block, unjudged (a
|
||||
monitoring unit's device-info answer comes back as it is; see
|
||||
`minimateplus.protocol.is_compliance_content`)."""
|
||||
return self._require_proto().read_compliance_content()
|
||||
|
||||
def read_settings_blocks(self) -> dict:
|
||||
"""The four blocks a settings write sends back, each as its read returns it:
|
||||
event index (08), settings (1A, logical), trigger (2E), waveform data (09)."""
|
||||
proto = self._require_proto()
|
||||
return {"event_index": proto.read_event_index(),
|
||||
"compliance": proto.read_compliance_content(),
|
||||
"trigger": proto.read_trigger_config(),
|
||||
"waveform": proto.read_waveform_data_raw()}
|
||||
|
||||
def write_call_home_image(self, image: bytes) -> None:
|
||||
"""Send a `0x7E` image (`call_home_image`) and its `0x7F` confirm, each ack
|
||||
checked -- framed once, never unescaped again. Raises ImageRefused before
|
||||
@@ -2108,253 +2012,6 @@ def _extract_project_strings(data: bytes) -> Optional[ProjectInfo]:
|
||||
)
|
||||
|
||||
|
||||
def _encode_compliance_config(
|
||||
raw: bytes,
|
||||
*,
|
||||
recording_mode: Optional[int] = None,
|
||||
sample_rate: Optional[int] = None,
|
||||
record_time: Optional[float] = None,
|
||||
trigger_level_geo: Optional[float] = None,
|
||||
alarm_level_geo: Optional[float] = None,
|
||||
geo_range: Optional[int] = None, # 0x00=Normal 10in/s, 0x01=Sensitive 1.25in/s
|
||||
histogram_interval_sec: Optional[int] = None,
|
||||
project: Optional[str] = None,
|
||||
client_name: Optional[str] = None,
|
||||
operator: Optional[str] = None,
|
||||
seis_loc: Optional[str] = None,
|
||||
notes: Optional[str] = None,
|
||||
) -> bytes:
|
||||
"""
|
||||
Patch a live 2126-byte compliance buffer (read from the device) with any
|
||||
supplied field values and return the 2128-byte write payload.
|
||||
|
||||
Only non-None arguments are modified; everything else is round-tripped verbatim.
|
||||
|
||||
Numeric field locations (all anchor-relative or label-relative — immune to
|
||||
DLE-jitter shifts):
|
||||
|
||||
Anchor: b'\\xbe\\x80\\x00\\x00\\x00\\x00' (confirmed stable, both BE11529 and BE18189)
|
||||
⚠ 2026-10-29: these RAW offsets were measured at 1024 sps, where the escape
|
||||
before `04` sits between the mode and the anchor. The decoder now reads
|
||||
the four fields after unescaping (mode -7, rate -6, interval -4, record
|
||||
time +6), so at any other layout these patch the wrong bytes. Until the
|
||||
encoder is rewritten on unescaped bytes (#46), a payload whose four fields
|
||||
do not read back as asked raises ValueError -- see the end of this function.
|
||||
recording_mode → uint8 at anchor_pos - 8 (raw; right at 1024 sps only)
|
||||
Values: 0x00=Single Shot, 0x01=Continuous, 0x03=Histogram, 0x04=Histogram+Continuous
|
||||
NOTE: The byte at anchor_pos - 7 is always 0x10 (a DLE marker regenerated by
|
||||
device firmware in every E5 response). It must NOT be overwritten during
|
||||
write — doing so causes anchor drift (+1 per write cycle).
|
||||
CORRECTION 2026-04-21: previous doc stated anchor-7 for write; empirically
|
||||
confirmed wrong — writing to anchor-7 shifts the anchor by 1 on every cycle.
|
||||
sample_rate → uint16 BE at anchor_pos - 6
|
||||
histogram_interval_sec → uint16 BE at anchor_pos - 4 (seconds; mode-gated to Histogram/Histogram+Continuous)
|
||||
Valid values: 2, 5, 15, 60, 300, 900 (= 2s, 5s, 15s, 1m, 5m, 15m)
|
||||
record_time → float32 BE at anchor_pos + 6
|
||||
|
||||
Channel block (anchored on b"Tran" with unit-string guard):
|
||||
geo_range → uint8 at tran_pos + 33 (confirmed 2026-04-20)
|
||||
0x00 = Normal 10.000 in/s, 0x01 = Sensitive 1.250 in/s
|
||||
Written to Tran, Vert, Long channel blocks (all three).
|
||||
adc_scale_factor → float32 BE at tran_pos + 28 (= 6.206053; do NOT write)
|
||||
trigger_level_geo → float32 BE at tran_pos + 34
|
||||
"in.\\x00" → unit string at tran_pos + 38 (layout guard)
|
||||
alarm_level_geo → float32 BE at tran_pos + 42
|
||||
"/s\\x00\\x00" → unit string at tran_pos + 46 (layout guard)
|
||||
NOTE: tran_pos+28 (float32 = 6.206053) is the ADC-to-velocity scale factor
|
||||
(= 1/sensitivity, (in/s)/V — Interface Handbook §4.5: 1.61133 V × 6.206053 = 10.000 in/s).
|
||||
This is a hardware/firmware constant common to all MiniMate Plus S3 units.
|
||||
It must NOT be written — do not add it back as a parameter.
|
||||
|
||||
String field locations (64-byte slots, label+22 format):
|
||||
b"Project:" → value at label_pos + 22, max 41 chars + null
|
||||
b"Client:" → value at label_pos + 22, max 41 chars + null
|
||||
b"User Name:" → value at label_pos + 22, max 41 chars + null
|
||||
b"Seis Loc:" → value at label_pos + 22, max 41 chars + null
|
||||
b"Extended Notes"→ value at label_pos + 22, max 41 chars + null
|
||||
|
||||
Returns:
|
||||
2128-byte write payload: patched 2126-byte buffer + 2-byte footer \\x00\\x00.
|
||||
(Checksum formula for the footer is unknown; \\x00\\x00 confirmed accepted
|
||||
by the device in POC test 2026-04-07.)
|
||||
|
||||
Raises:
|
||||
ValueError: if raw is shorter than the minimum needed for the 3-chunk write.
|
||||
"""
|
||||
# Total size is nominally ~2126 bytes but varies by ±1-2 bytes depending on
|
||||
# DLE jitter in the E5 read response (0x10 bytes in the config data cause
|
||||
# 1-byte expansions per occurrence during DLE stuffing/unstuffing). The
|
||||
# anchor-based field access and the chunk splitter (fixed chunk1=1027,
|
||||
# chunk2=1055, chunk3=remainder) both handle variable length correctly.
|
||||
# Only enforce a minimum — must have at least chunk1+chunk2 bytes of content.
|
||||
_MIN_COMPLIANCE_LEN = 1027 + 1055 # = 2082
|
||||
if len(raw) < _MIN_COMPLIANCE_LEN:
|
||||
raise ValueError(
|
||||
f"_encode_compliance_config: compliance buffer too short "
|
||||
f"({len(raw)} bytes, need at least {_MIN_COMPLIANCE_LEN})"
|
||||
)
|
||||
if len(raw) not in range(2124, 2132):
|
||||
log.warning(
|
||||
"_encode_compliance_config: unusual compliance buffer length %d "
|
||||
"(expected ~2126); proceeding with anchor-based access",
|
||||
len(raw),
|
||||
)
|
||||
|
||||
buf = bytearray(raw)
|
||||
|
||||
# ── Numeric: recording_mode + sample_rate + record_time (anchor-relative) ──
|
||||
_ANC = b'\xbe\x80\x00\x00\x00\x00'
|
||||
_anc = buf.find(_ANC, 0, 150)
|
||||
|
||||
# Log anchor position every time so we can detect unexpected shifts due to
|
||||
# DLE jitter or firmware differences. Expected position is ~15.
|
||||
if _anc < 0:
|
||||
log.warning(
|
||||
"_encode_compliance_config: anchor NOT FOUND in cfg[0:150] "
|
||||
"(buf len=%d) — all anchor-relative writes will be skipped",
|
||||
len(buf),
|
||||
)
|
||||
else:
|
||||
log.info(
|
||||
"_encode_compliance_config: anchor at cfg[%d] buf_len=%d "
|
||||
"(recording_mode@%d DLE_marker@%d sample_rate@%d:%d "
|
||||
"histogram_interval@%d:%d record_time@%d:%d)",
|
||||
_anc, len(buf),
|
||||
_anc - 8,
|
||||
_anc - 7,
|
||||
_anc - 6, _anc - 4,
|
||||
_anc - 4, _anc - 2,
|
||||
_anc + 6, _anc + 10,
|
||||
)
|
||||
|
||||
if recording_mode is not None:
|
||||
if _anc < 8:
|
||||
log.warning("_encode_compliance_config: anchor not found — cannot write recording_mode")
|
||||
else:
|
||||
# Write to anchor-8, same physical position as the E5 read format.
|
||||
# The byte at anchor-7 is a DLE marker (0x10) that the device firmware
|
||||
# regenerates in every E5 response — it must NOT be overwritten.
|
||||
# Writing to anchor-7 causes the device to add an extra byte on the
|
||||
# next read-back, drifting the anchor by +1 on every write cycle.
|
||||
# (CLAUDE.md "anchor-7 write" was incorrect — confirmed 2026-04-21)
|
||||
buf[_anc - 8] = recording_mode & 0xFF
|
||||
log.debug("_encode_compliance_config: recording_mode=0x%02X -> offset %d",
|
||||
recording_mode, _anc - 8)
|
||||
|
||||
if sample_rate is not None:
|
||||
if _anc < 6:
|
||||
log.warning("_encode_compliance_config: anchor not found — cannot write sample_rate")
|
||||
else:
|
||||
struct.pack_into(">H", buf, _anc - 6, sample_rate)
|
||||
log.debug("_encode_compliance_config: sample_rate=%d -> offset %d", sample_rate, _anc - 6)
|
||||
|
||||
if histogram_interval_sec is not None:
|
||||
if _anc < 4:
|
||||
log.warning("_encode_compliance_config: anchor not found — cannot write histogram_interval")
|
||||
else:
|
||||
struct.pack_into(">H", buf, _anc - 4, histogram_interval_sec)
|
||||
log.debug("_encode_compliance_config: histogram_interval=%ds -> offset %d",
|
||||
histogram_interval_sec, _anc - 4)
|
||||
|
||||
if record_time is not None:
|
||||
if _anc < 0 or _anc + 10 > len(buf):
|
||||
log.warning("_encode_compliance_config: anchor not found — cannot write record_time")
|
||||
else:
|
||||
struct.pack_into(">f", buf, _anc + 6, record_time)
|
||||
log.debug("_encode_compliance_config: record_time=%.3f -> offset %d", record_time, _anc + 6)
|
||||
|
||||
# ── Numeric: channel block (Tran label + unit-string guard) ───────────────
|
||||
# NOTE: tran_pos+24 (write format) or tran_pos+28 (E5 read format) is the
|
||||
# ADC-to-velocity scale factor (6.206053, hardware constant — never written).
|
||||
# geo_range is written to ALL THREE geo channel blocks (Tran, Vert, Long),
|
||||
# confirmed from 4-20-26 captures showing the byte at label+29 in each block.
|
||||
_needs_channel = any(v is not None for v in (trigger_level_geo, alarm_level_geo, geo_range))
|
||||
if _needs_channel:
|
||||
_tran = buf.find(b"Tran", 44)
|
||||
_valid = (
|
||||
_tran >= 0
|
||||
and buf[_tran + 4 : _tran + 5] != b"2"
|
||||
and _tran + 50 <= len(buf)
|
||||
and buf[_tran + 38 : _tran + 42] == b"in.\x00"
|
||||
and buf[_tran + 46 : _tran + 50] == b"/s\x00\x00"
|
||||
)
|
||||
if not _valid:
|
||||
log.warning(
|
||||
"_encode_compliance_config: 'Tran' channel block not found or unit "
|
||||
"guard failed — trigger/alarm/geo_range will not be written"
|
||||
)
|
||||
else:
|
||||
if trigger_level_geo is not None:
|
||||
struct.pack_into(">f", buf, _tran + 34, trigger_level_geo)
|
||||
log.debug("_encode_compliance_config: trigger_level_geo=%.4f -> offset %d", trigger_level_geo, _tran + 34)
|
||||
if alarm_level_geo is not None:
|
||||
struct.pack_into(">f", buf, _tran + 42, alarm_level_geo)
|
||||
log.debug("_encode_compliance_config: alarm_level_geo=%.4f -> offset %d", alarm_level_geo, _tran + 42)
|
||||
if geo_range is not None:
|
||||
# Write geo_range to all three geo channel blocks (Tran, Vert, Long).
|
||||
# Field at label+33 in the E5-format compliance bytes (same in read and write
|
||||
# since the 2126-byte payload is round-tripped verbatim).
|
||||
# 0x00 = Normal 10.000 in/s, 0x01 = Sensitive 1.250 in/s.
|
||||
for _ch_label in (b"Tran", b"Vert", b"Long"):
|
||||
_ch = buf.find(_ch_label, 44)
|
||||
if _ch >= 0 and buf[_ch + 4 : _ch + 5] != b"2" and _ch + 34 <= len(buf):
|
||||
buf[_ch + 33] = geo_range & 0xFF
|
||||
log.debug(
|
||||
"_encode_compliance_config: geo_range=0x%02X -> %s+33 offset %d",
|
||||
geo_range, _ch_label.decode(), _ch + 33,
|
||||
)
|
||||
|
||||
# ── ASCII strings (64-byte slot, value at label_pos+22) ───────────────────
|
||||
def _set_string(label: bytes, value: Optional[str]) -> None:
|
||||
if value is None:
|
||||
return
|
||||
idx = buf.find(label)
|
||||
if idx < 0:
|
||||
log.warning("_encode_compliance_config: label %r not found", label)
|
||||
return
|
||||
val_bytes = value.encode("ascii", errors="replace")[:_COMPLIANCE_VALUE_MAX - 1]
|
||||
padded = val_bytes + b"\x00" * (_COMPLIANCE_VALUE_MAX - len(val_bytes))
|
||||
buf[idx + _COMPLIANCE_VALUE_OFFSET : idx + _COMPLIANCE_SLOT_SIZE] = padded
|
||||
log.debug("_encode_compliance_config: %r -> %r", label, value)
|
||||
|
||||
_set_string(b"Project:", project)
|
||||
_set_string(b"Client:", client_name)
|
||||
_set_string(b"User Name:", operator)
|
||||
_set_string(b"Seis Loc:", seis_loc)
|
||||
_set_string(b"Extended Notes", notes)
|
||||
|
||||
# ── Read-back check: the payload must decode to what was asked ────────────
|
||||
# The decoder is the measured layout (every recorded reply); these offsets are
|
||||
# 1024-sps raw ones. A mode change on BE9441's 10-25 Continuous / 4096 block
|
||||
# rewrote the byte in front of the mode and read back unchanged. Refuse it
|
||||
# here, before push_config_raw sends anything.
|
||||
asked = {"recording_mode": recording_mode, "sample_rate": sample_rate,
|
||||
"histogram_interval_sec": histogram_interval_sec, "record_time": record_time}
|
||||
if any(v is not None for v in asked.values()):
|
||||
before, after = _settings_read_back(raw), _settings_read_back(bytes(buf))
|
||||
if record_time is not None:
|
||||
asked["record_time"] = struct.unpack(">f", struct.pack(">f", record_time))[0]
|
||||
want = {k: (v if v is not None else before[k]) for k, v in asked.items()}
|
||||
wrong = {k: (after[k], want[k]) for k in asked if after[k] != want[k]}
|
||||
if wrong:
|
||||
raise ValueError(
|
||||
"_encode_compliance_config: the patched block would not read back as asked ("
|
||||
+ ", ".join(f"{k} reads {got!r}, not {exp!r}" for k, (got, exp) in wrong.items())
|
||||
+ ") -- refused, nothing built or sent. The encoder's offsets were measured at "
|
||||
"1024 sps and need rewriting on unescaped bytes (#46)."
|
||||
)
|
||||
|
||||
# 2-byte footer — checksum formula unknown; \x00\x00 confirmed accepted by device
|
||||
return bytes(buf) + b"\x00\x00"
|
||||
|
||||
|
||||
def _settings_read_back(data: bytes) -> dict:
|
||||
"""Mode, sample rate, interval and record time as the decoder reads `data`."""
|
||||
info = DeviceInfo(serial="", firmware_minor=0)
|
||||
_decode_compliance_config_into(data, info)
|
||||
cc = info.compliance_config
|
||||
return {k: getattr(cc, k, None) if cc is not None else None
|
||||
for k in ("recording_mode", "sample_rate", "histogram_interval_sec", "record_time")}
|
||||
|
||||
|
||||
def _decode_compliance_config_into(data: bytes, info: DeviceInfo) -> None:
|
||||
|
||||
+143
-16
@@ -13,13 +13,16 @@ Pure: no I/O, and no import from `sfm/`.
|
||||
"""
|
||||
from __future__ import annotations
|
||||
|
||||
import datetime
|
||||
import math
|
||||
import re
|
||||
from dataclasses import dataclass
|
||||
from dataclasses import dataclass, field
|
||||
from typing import Callable, Optional, Sequence
|
||||
|
||||
from .bw_xml_report import XmlReport
|
||||
from .event_file_io import (_GEO_FS_BY_RANGE, _GEO_INT16_FS, _GEO_NORMAL_FS_INS, _MIC_PSI_PER_COUNT,
|
||||
from .event_file_io import (interval_times, _GEO_FS_BY_RANGE, _GEO_INT16_FS, _GEO_NORMAL_FS_INS, _MIC_PSI_PER_COUNT,
|
||||
decode_blastware_bytes)
|
||||
from .histogram_codec import half_period_to_hz
|
||||
from .models import Event
|
||||
from .waveform_codec import mic_count_to_db
|
||||
|
||||
@@ -30,6 +33,50 @@ GEO_IPS_PER_COUNT: float = _GEO_NORMAL_FS_INS / _GEO_INT16_FS
|
||||
_CHANNELS = ("Tran", "Vert", "Long", "MicL")
|
||||
_EVENT_TYPE = {"Waveform": "Full Waveform", "Histogram": "Full Histogram"}
|
||||
|
||||
# How Blastware prints the setup fields SFM reads (measured 2026-11-03).
|
||||
_MONTHS = ("January", "February", "March", "April", "May", "June", "July",
|
||||
"August", "September", "October", "November", "December")
|
||||
_TRIGGERED_BY = {0x0001: "Tran", 0x0002: "Vert", 0x0004: "Long", 0x0008: "MicL", 0x0200: "Manual"}
|
||||
_STOP_MODES = {0: "Fixed"}
|
||||
_MIC_TYPES = {2: "Linear Weighting"}
|
||||
_GEO_TRIGGERS, _MIC_TRIGGER = 0x07, 0x08
|
||||
# Blastware turns the mic trigger level from psi to dB with 6895 Pa per psi, not
|
||||
# 6894.757: 4,272 / 4,272 DL2 levels against 4,271 (the odd one 0.01 psi,
|
||||
# printed 130.8 dB(L), is 130.7498 at the exact constant).
|
||||
_TRIGGER_PA_PER_PSI = 6895.0
|
||||
|
||||
|
||||
def _setup_values(ev: Event) -> dict[str, object]:
|
||||
out: dict[str, object] = {}
|
||||
di = ev.device_info
|
||||
if di is not None:
|
||||
out["SerialNumber"] = di.serial
|
||||
fw = di.firmware_version or ""
|
||||
if di.dsp_version and fw.startswith("S33") and di.model:
|
||||
# "V 10.72-8.17 MiniMate Plus" from "10.72", "S338.17" and the model --
|
||||
# the only version in DL2, so the rule is proven for it alone.
|
||||
out["Version"] = f"V {di.dsp_version}-{fw[3:]} {di.model}"
|
||||
if di.calibration_date and di.calibrated_by:
|
||||
c = di.calibration_date
|
||||
out["Calibration"] = f"{_MONTHS[c.month - 1]} {c.day}, {c.year} by {di.calibrated_by}"
|
||||
out["BatteryLevel"] = ev.battery_volts
|
||||
out["Trigger"] = _TRIGGERED_BY.get(ev.triggered_by)
|
||||
out["RecordStopMode"] = _STOP_MODES.get(ev.record_stop_mode)
|
||||
out["Microphone"] = _MIC_TYPES.get(ev.mic_type)
|
||||
# dB or psi is Blastware's preference, not the unit's (carve-out
|
||||
# units-is-a-display-preference); SFM reports dB, the default.
|
||||
out["Units"] = "in/s and dB(L)" if ev.mic_type is not None else "in/s"
|
||||
# Blastware prints a trigger level only for a channel that is a trigger
|
||||
# source, and none for a Manual trigger.
|
||||
src, manual = ev.trigger_sources or 0, ev.triggered_by == 0x0200
|
||||
if src & _GEO_TRIGGERS and not manual:
|
||||
out["GeoTriggerLevel"] = ev.trigger_level_geo
|
||||
if src & _MIC_TRIGGER and not manual and ev.trigger_level_mic_psi:
|
||||
psi = ev.trigger_level_mic_psi
|
||||
out["MicTriggerLevel psi(L)"] = psi
|
||||
out["MicTriggerLevel dB(L)"] = 20 * math.log10(psi * _TRIGGER_PA_PER_PSI / 2e-5)
|
||||
return out
|
||||
|
||||
|
||||
@dataclass
|
||||
class SfmSide:
|
||||
@@ -40,6 +87,27 @@ class SfmSide:
|
||||
channels: list[str] # channels with decoded data, in Tran/Vert/Long/MicL order
|
||||
counts: dict[str, list[int]] # waveform samples or histogram interval peaks
|
||||
geo_ips_per_count: float = GEO_IPS_PER_COUNT # at the event's range, as SFM read it
|
||||
# interval column -> SFM's value per interval (a number, or Blastware's word)
|
||||
interval_values: dict[str, list[object]] = field(default_factory=dict)
|
||||
interval_times: Optional[list[str]] = None # each interval's printed time
|
||||
|
||||
|
||||
def interval_frequency(halfp: int, sample_rate: int) -> object:
|
||||
"""An interval's frequency as Blastware prints it: "N/A" for a half-period
|
||||
of 0, ">100" (">200" at 2048 sps) at 5 samples or fewer, "<1.0" below 1 Hz,
|
||||
else (sample rate / 2) / half-period in Hz. Measured on ~3.1 M DL2 cells,
|
||||
2026-11-03 (#50: the rate, not a fixed 512)."""
|
||||
if halfp == 0:
|
||||
return "N/A"
|
||||
hz = half_period_to_hz(halfp, sample_rate)
|
||||
if hz is None:
|
||||
return f">{round(100 * sample_rate / 1024)}"
|
||||
return "<1.0" if hz < 1.0 else hz
|
||||
|
||||
|
||||
def _interval_size(seconds: int) -> str:
|
||||
n, unit = (seconds // 60, "minute") if seconds % 60 == 0 else (seconds, "second")
|
||||
return f"{n} {unit}{'' if n == 1 else 's'}"
|
||||
|
||||
|
||||
def sfm_side(raw: bytes) -> SfmSide:
|
||||
@@ -69,9 +137,46 @@ def sfm_side(raw: bytes) -> SfmSide:
|
||||
if pv is not None:
|
||||
values.update(TranPPV=pv.tran, VertPPV=pv.vert, LongPPV=pv.long,
|
||||
PeakVectorSum=pv.peak_vector_sum)
|
||||
# A waveform's peak detail (None on a histogram, so not reported).
|
||||
for tag, value in (("TranTimeofPeak", pv.tran_time_of_peak),
|
||||
("VertTimeofPeak", pv.vert_time_of_peak),
|
||||
("LongTimeofPeak", pv.long_time_of_peak),
|
||||
("MicLTimeofPeak", pv.micl_time_of_peak),
|
||||
("PeakVectorSumTimeSum", pv.pvs_time),
|
||||
("TranPeakAcceleration", pv.tran_peak_accel_g),
|
||||
("VertPeakAcceleration", pv.vert_peak_accel_g),
|
||||
("LongPeakAcceleration", pv.long_peak_accel_g)):
|
||||
if value is not None:
|
||||
values[tag] = value
|
||||
if counts["MicL"]:
|
||||
values["MicLPSPL dB(L)"] = mic_count_to_db(max(abs(c) for c in counts["MicL"]))
|
||||
values["MicLPSPL psi(L)"] = pv.micl if pv is not None else None
|
||||
values.update(_setup_values(ev))
|
||||
if ev.stop_time is not None:
|
||||
values.update(HistogramStopDate=ev.stop_time.strftime("%Y-%m-%d"),
|
||||
HistogramStopTime=ev.stop_time.strftime("%H:%M:%S"))
|
||||
if ev.histogram_interval_sec:
|
||||
values["IntervalSize"] = _interval_size(ev.histogram_interval_sec)
|
||||
interval_values: dict[str, list[object]] = {}
|
||||
if ev.interval_half_periods and ev.sample_rate:
|
||||
for ch, hps in ev.interval_half_periods.items():
|
||||
interval_values[f"{ch} Freq Hz"] = [interval_frequency(h, ev.sample_rate) for h in hps]
|
||||
if ev.interval_pvs:
|
||||
interval_values["Geo PVS in/s"] = list(ev.interval_pvs)
|
||||
times = None
|
||||
n = len(counts["Tran"])
|
||||
if ev.record_type == "Histogram" and ts is not None and ev.histogram_interval_sec and n:
|
||||
start = datetime.datetime(ts.year, ts.month, ts.day, ts.hour, ts.minute, ts.second)
|
||||
ends = interval_times(start, ev.histogram_interval_sec, ev.stop_time, n)
|
||||
times = [t.strftime("%Y-%m-%d %H:%M:%S") for t in ends]
|
||||
# A peak's date and time are those of the interval holding it (first).
|
||||
for tag, series in (("TranPeak", counts["Tran"]), ("VertPeak", counts["Vert"]),
|
||||
("LongPeak", counts["Long"]), ("MicL", counts["MicL"]),
|
||||
("PeakVectorSum", ev.interval_pvs)):
|
||||
if series and len(series) == n:
|
||||
j = max(range(n), key=lambda q: abs(series[q]))
|
||||
values[f"{tag}Date"] = ends[j].strftime("%Y-%m-%d")
|
||||
values[f"{tag}Time"] = ends[j].strftime("%H:%M:%S")
|
||||
|
||||
return SfmSide(
|
||||
event=ev,
|
||||
@@ -82,6 +187,8 @@ def sfm_side(raw: bytes) -> SfmSide:
|
||||
channels=[ch for ch in _CHANNELS if counts[ch]],
|
||||
counts=counts,
|
||||
geo_ips_per_count=_GEO_FS_BY_RANGE.get(ev.geo_range, _GEO_NORMAL_FS_INS) / _GEO_INT16_FS,
|
||||
interval_values=interval_values,
|
||||
interval_times=times,
|
||||
)
|
||||
|
||||
|
||||
@@ -144,10 +251,12 @@ def _mic_converter(ref: XmlReport) -> Optional[Callable[[int], float]]:
|
||||
def _compare_scalar(tag: str, printed: str, sfm: SfmSide, ref: XmlReport) -> FieldResult:
|
||||
if not printed.strip() or printed.strip() == "N/A":
|
||||
return FieldResult(tag, "no_reference", printed, None)
|
||||
if tag == "MicLPSPL":
|
||||
units = ref.event_units or ""
|
||||
key = ("MicLPSPL dB(L)" if "dB(L)" in units else
|
||||
"MicLPSPL psi(L)" if "psi(L)" in units else None)
|
||||
if tag in ("MicLPSPL", "MicTriggerLevel"):
|
||||
# A printed value that states its unit is compared in that unit:
|
||||
# K441LA17.IN0W's Units say psi(L), its MicTriggerLevel "125.0 dB(L)".
|
||||
units = printed if ("dB(L)" in printed or "psi(L)" in printed) else (ref.event_units or "")
|
||||
key = (f"{tag} dB(L)" if "dB(L)" in units else
|
||||
f"{tag} psi(L)" if "psi(L)" in units else None)
|
||||
value = sfm.values.get(key) if key else None
|
||||
else:
|
||||
value = sfm.values.get(tag)
|
||||
@@ -166,9 +275,11 @@ def _compare_scalar(tag: str, printed: str, sfm: SfmSide, ref: XmlReport) -> Fie
|
||||
return FieldResult(tag, "match" if ok else "mismatch", printed, _render(value, printed))
|
||||
|
||||
|
||||
def _cell_diff(value: float, printed: str) -> Optional[float]:
|
||||
def _cell_diff(value: object, printed: str) -> Optional[float]:
|
||||
"""|value - printed| when the cell disagrees, else None; inf for a cell that
|
||||
is not a number."""
|
||||
is not a number. A word on SFM's side (">100", "N/A") must be printed."""
|
||||
if isinstance(value, str):
|
||||
return None if _same_text(value, printed) else float("inf")
|
||||
p = _printed_number(printed)
|
||||
if p is None:
|
||||
return float("inf")
|
||||
@@ -237,14 +348,19 @@ def series_pairs(sfm: SfmSide, ref: XmlReport,
|
||||
if field.startswith("intervals."):
|
||||
title = field[len("intervals."):]
|
||||
columns = ref.interval_columns or []
|
||||
convert = _interval_converter(title, sfm)
|
||||
counts = sfm.counts.get(title.partition(" ")[0], [])
|
||||
if convert is None or not counts or title not in columns:
|
||||
if title not in columns:
|
||||
return None
|
||||
i = columns.index(title)
|
||||
cells = [row[i] if i < len(row) else "" for _, row in (ref.intervals or [])]
|
||||
pairs = [(j, cell, convert(c)) for j, (cell, c) in enumerate(zip(cells, counts))]
|
||||
return pairs, abs(len(cells) - len(counts))
|
||||
values = sfm.interval_values.get(title)
|
||||
if values is None:
|
||||
convert = _interval_converter(title, sfm)
|
||||
counts = sfm.counts.get(title.partition(" ")[0], [])
|
||||
if convert is None or not counts:
|
||||
return None
|
||||
values = [convert(c) for c in counts]
|
||||
pairs = [(j, cell, v) for j, (cell, v) in enumerate(zip(cells, values))]
|
||||
return pairs, abs(len(cells) - len(values))
|
||||
return None
|
||||
|
||||
|
||||
@@ -254,7 +370,9 @@ def _compare_series(field: str, n_bw: int, sfm: SfmSide, ref: XmlReport) -> Fiel
|
||||
return FieldResult(field, "sfm_blank", f"{n_bw} rows", None)
|
||||
pairs, row_len = got
|
||||
diffs = [(j, d) for j, cell, v in pairs if (d := _cell_diff(v, cell)) is not None]
|
||||
n_sfm = len(sfm.counts.get(field.split(".", 1)[1].partition(" ")[0], []))
|
||||
title = field.split(".", 1)[1]
|
||||
n_sfm = (len(sfm.interval_values[title]) if title in sfm.interval_values
|
||||
else len(sfm.counts.get(title.partition(" ")[0], [])))
|
||||
return _series_result(field, n_bw, n_sfm, diffs, row_len)
|
||||
|
||||
|
||||
@@ -265,12 +383,21 @@ def _compare_samples(sfm: SfmSide, ref: XmlReport) -> list[FieldResult]:
|
||||
|
||||
|
||||
def _compare_intervals(sfm: SfmSide, ref: XmlReport) -> list[FieldResult]:
|
||||
"""One result per column, plus the interval times, which SFM does not keep."""
|
||||
"""One result per column, plus the interval times."""
|
||||
n = len(ref.intervals or [])
|
||||
return ([FieldResult("intervals.Time", "sfm_blank", f"{n} rows", None)]
|
||||
return ([_compare_interval_times(sfm, ref, n)]
|
||||
+ [_compare_series(f"intervals.{t}", n, sfm, ref) for t in ref.interval_columns or []])
|
||||
|
||||
|
||||
def _compare_interval_times(sfm: SfmSide, ref: XmlReport, n: int) -> FieldResult:
|
||||
if sfm.interval_times is None:
|
||||
return FieldResult("intervals.Time", "sfm_blank", f"{n} rows", None)
|
||||
diffs = [(j, float("inf")) for j, ((t, _), s) in enumerate(zip(ref.intervals or [], sfm.interval_times))
|
||||
if not _same_text(s, t)]
|
||||
return _series_result("intervals.Time", n, len(sfm.interval_times), diffs,
|
||||
abs(n - len(sfm.interval_times)))
|
||||
|
||||
|
||||
def compare(sfm: SfmSide, ref: XmlReport, carveouts: Sequence["Carveout"] = ()) -> list[FieldResult]:
|
||||
"""Every field Blastware's report carries, set against what SFM produced.
|
||||
A mismatch a carve-out covers and applies to becomes `accepted`."""
|
||||
|
||||
@@ -68,6 +68,21 @@ def _saturation(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool:
|
||||
got = series_pairs(sfm, ref, res.field)
|
||||
if got is None or got[1]:
|
||||
return False
|
||||
if res.field == "intervals.Geo PVS in/s":
|
||||
# Per interval, as PeakVectorSum: an OORANGE vector sum, SFM's sum within
|
||||
# three channels at the ceiling, and a channel Blastware itself clamped in
|
||||
# that interval. 17 / 17 DL2 cells, SFM 10.01 .. 17.33 (2026-11-03).
|
||||
cols = ref.interval_columns or []
|
||||
peaks = [cols.index(c) for c in ("Tran Peak in/s", "Vert Peak in/s", "Long Peak in/s")
|
||||
if c in cols]
|
||||
rows = ref.intervals or []
|
||||
differing = [(j, cell, v) for j, cell, v in got[0]
|
||||
if isinstance(v, str) or not matches_printed(v, cell)]
|
||||
return bool(differing) and all(
|
||||
cell.strip() == "OORANGE" and not isinstance(v, str)
|
||||
and r - _TOL <= v <= 3 ** 0.5 * r * 1.01
|
||||
and any(_clamped(rows[j][1][p], r) for p in peaks if p < len(rows[j][1]))
|
||||
for j, cell, v in differing)
|
||||
differing = [(cell, v) for _, cell, v in got[0] if not matches_printed(v, cell)]
|
||||
return bool(differing) and all(
|
||||
_clamped(cell, r) and _at_ceiling(v, r)
|
||||
@@ -79,10 +94,13 @@ SATURATION = Carveout(
|
||||
id="saturation",
|
||||
fields=("TranPPV", "VertPPV", "LongPPV", "PeakVectorSum",
|
||||
"samples.Tran", "samples.Vert", "samples.Long",
|
||||
"intervals.Tran Peak in/s", "intervals.Vert Peak in/s", "intervals.Long Peak in/s"),
|
||||
"intervals.Tran Peak in/s", "intervals.Vert Peak in/s", "intervals.Long Peak in/s",
|
||||
"intervals.Geo PVS in/s"),
|
||||
evidence=("Blastware clamps a clipped channel to the range maximum and prints OORANGE; "
|
||||
"the file holds counts past full scale (32016 counts = 10.005 in/s observed). "
|
||||
"scratch/verify_against_ascii.py, 2026-08-28."),
|
||||
"scratch/verify_against_ascii.py, 2026-08-28. An interval's vector sum prints "
|
||||
"OORANGE when it exceeds the range in an interval with a clamped channel: 17 / 17 "
|
||||
"DL2 cells, 2026-11-03."),
|
||||
applies=_saturation,
|
||||
)
|
||||
|
||||
@@ -106,4 +124,29 @@ INTERVAL_COUNT_IS_DURATION = Carveout(
|
||||
applies=_interval_count_is_duration,
|
||||
)
|
||||
|
||||
CARVEOUTS: tuple[Carveout, ...] = (SATURATION, INTERVAL_COUNT_IS_DURATION)
|
||||
_MIC_UNITS = ("in/s and dB(L)", "in/s and psi(L)")
|
||||
|
||||
|
||||
def _units_is_a_display_preference(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool:
|
||||
"""Both sides say the event has a mic; they differ only in dB against psi."""
|
||||
return (" ".join((res.bw or "").split()) in _MIC_UNITS
|
||||
and sfm.values.get("Units") in _MIC_UNITS)
|
||||
|
||||
|
||||
UNITS_IS_A_DISPLAY_PREFERENCE = Carveout(
|
||||
id="units-is-a-display-preference",
|
||||
fields=("Units",),
|
||||
evidence=("dB(L) or psi(L) is Blastware's display preference on the PC when it wrote the "
|
||||
"report, not the unit's: in report-write order (the _XML.XML mtimes) DL2's 70,034 "
|
||||
"reports switch fleet-wide in 61 clean runs, every unit at once, and no byte or "
|
||||
"bit of the event file separates the two (k-240 .. k+520, nor the 1.2 KB before "
|
||||
"the footer). Instantel documents both settings: the unit's own Microphone "
|
||||
"Units (MiniMate Plus manual 716U0101 Rev 15 §3.9.7: psi(L), dB(L) or Pa(L), "
|
||||
"keypad Right Arrow + Setups) and Blastware's report preference (Blastware "
|
||||
"manual 714U0301 Rev 22 §4, Preferences > Units and Channel: Show Mic in dB / "
|
||||
"in Linear Units). 2026-11-03."),
|
||||
applies=_units_is_a_display_preference,
|
||||
)
|
||||
|
||||
CARVEOUTS: tuple[Carveout, ...] = (SATURATION, INTERVAL_COUNT_IS_DURATION,
|
||||
UNITS_IS_A_DISPLAY_PREFERENCE)
|
||||
+238
-28
@@ -19,18 +19,19 @@ import datetime
|
||||
import hashlib
|
||||
import json
|
||||
import logging
|
||||
import math
|
||||
import os
|
||||
import re
|
||||
import struct
|
||||
from pathlib import Path
|
||||
from typing import Optional, Union
|
||||
|
||||
from .models import Event, PeakValues, ProjectInfo, Timestamp
|
||||
from .models import DeviceInfo, Event, PeakValues, ProjectInfo, Timestamp
|
||||
from . import blastware_file as _bw # avoid circular reference at module load
|
||||
from .bw_ascii_report import BwAsciiReport
|
||||
from . import waveform_codec as _wc
|
||||
from .waveform_codec import decode_waveform_v2, decoded_to_adc_counts
|
||||
from .histogram_codec import decode_histogram_body, interval_pvs
|
||||
from .histogram_codec import channels_from_records, decode_histogram_body, decode_histogram_body_full
|
||||
|
||||
# Reference pressure for dB(L) → psi conversion (20 µPa expressed in psi).
|
||||
# Same constant as sfm/sfm_webapp.html so server-side and browser-side
|
||||
@@ -51,7 +52,7 @@ SIDECAR_KIND = "sfm.event"
|
||||
# bumped without a `pip install` re-run — leading to confusing stale
|
||||
# version stamps in sidecars. Bump this constant and CHANGELOG.md
|
||||
# together at release time.
|
||||
TOOL_VERSION = "0.33.0" # setup + notes, record type, histogram PVS and mic from the file; gates the backfill regen
|
||||
TOOL_VERSION = "0.34.0" # file-only decode groups A-D, histogram times (#51); gates the backfill regen
|
||||
|
||||
try:
|
||||
# Best-effort: prefer the installed metadata when it's NEWER than the
|
||||
@@ -793,6 +794,45 @@ def _peaks_from_samples(samples: dict[str, list[int]],
|
||||
)
|
||||
|
||||
|
||||
# Blastware's g for peak acceleration, fitted: every printed acceleration in
|
||||
# DL2 bounds it, and together they leave [386.2236, 386.2240] in/s^2 -- 19,475 /
|
||||
# 19,479 values fit (the other 4: one odd file, O117I1NK.R70W, and one sample
|
||||
# mismatch). That is 9.81 m/s^2 (386.2205) plus an offset not explained, as
|
||||
# with the mic's fitted dB offset; 9.81 gives 19,423, the standard 9.80665 gives
|
||||
# 17,806 (2026-11-04).
|
||||
_ACCEL_IPS2_PER_G = 386.2238
|
||||
|
||||
|
||||
def _waveform_peak_detail(pv: PeakValues, samples: dict[str, list[int]], geo_fs_ins: float,
|
||||
sample_rate: int, pretrig: int) -> None:
|
||||
"""A waveform's time of peak per channel, the vector sum's time and each
|
||||
geophone's peak acceleration, on `pv`. Measured on 400 DL2 waveforms
|
||||
(2026-11-04):
|
||||
* time of peak = (first peak sample - pre-trigger samples) / sample rate,
|
||||
1,197 / 1,197; the vector-sum time is the same on sqrt(T^2 + V^2 + L^2),
|
||||
398 / 399
|
||||
* peak acceleration = the largest |v[i+1] - v[i]| x sample rate / g,
|
||||
with Blastware's fitted g -- the manuals: "subtracts two velocity
|
||||
readings and divides the result by the elapsed time between them"."""
|
||||
scale = geo_fs_ins / _GEO_INT16_FS
|
||||
geo = {}
|
||||
for ch in ("Tran", "Vert", "Long", "MicL"):
|
||||
c = samples.get(ch) or []
|
||||
if not c:
|
||||
continue
|
||||
i = max(range(len(c)), key=lambda k: abs(c[k]))
|
||||
setattr(pv, f"{ch.lower()}_time_of_peak", (i - pretrig) / sample_rate)
|
||||
if ch != "MicL":
|
||||
geo[ch] = c
|
||||
step = max((abs(c[k + 1] - c[k]) for k in range(len(c) - 1)), default=0)
|
||||
setattr(pv, f"{ch.lower()}_peak_accel_g", step * scale * sample_rate / _ACCEL_IPS2_PER_G)
|
||||
if len(geo) == 3:
|
||||
n = min(len(c) for c in geo.values())
|
||||
t, v, l = geo["Tran"], geo["Vert"], geo["Long"]
|
||||
j = max(range(n), key=lambda k: t[k] * t[k] + v[k] * v[k] + l[k] * l[k])
|
||||
pv.pvs_time = (j - pretrig) / sample_rate
|
||||
|
||||
|
||||
# STRT[18], the record-type byte (#41): 0x46 on every one of DL2's 6,577
|
||||
# waveform files and 0x0A on every one of its 63,535 histograms (measured
|
||||
# 2026-10-29). Manual / Event / Combo never occur there, so their bytes are
|
||||
@@ -862,6 +902,7 @@ _RECTIME_OFFSET_BEFORE_MARKER = 30
|
||||
# 2026-10-29). Offsets are from the first byte of the name.
|
||||
_SETUP_NAME_RE = re.compile(rb"\x1c\x08([\x20-\x7e]{1,40})\x00")
|
||||
_SAMPLE_RATE_BEFORE_NAME = 42 # uint16 BE, samples per second
|
||||
_INTERVAL_BEFORE_NAME = 40 # uint16 BE, histogram interval in seconds (2 / 5 / 15 / 60 / 300)
|
||||
_PRETRIG_BEFORE_NAME = 36 # float32 BE, seconds, negative (-0.25, -0.0625 ...)
|
||||
_RECTIME_BEFORE_NAME = 30 # float32 BE, seconds (the marker's offset above)
|
||||
_SAMPLE_RATES = (1024, 2048, 4096)
|
||||
@@ -895,17 +936,22 @@ def _ts8(b: bytes) -> Optional[datetime.datetime]:
|
||||
def _embedded_event_record(
|
||||
raw: bytes, end: int, start: Optional[datetime.datetime],
|
||||
stop: Optional[datetime.datetime], record_time: Optional[float],
|
||||
) -> tuple[Optional[datetime.datetime], str]:
|
||||
"""The trigger time from the instrument's embedded event record, or (None, why).
|
||||
) -> tuple[Optional[datetime.datetime], str, Optional[int]]:
|
||||
"""The trigger time and trigger source from the instrument's embedded event
|
||||
record, or (None, why, None).
|
||||
|
||||
Every `fe 80` before `end` (the footer) is a candidate. One counts only if
|
||||
its lead bytes match, both its times are well formed, the footer's session
|
||||
start <= trigger <= its stop, its stop is the footer's stop or a second
|
||||
before it, and its length agrees with the record time. Exactly one may
|
||||
pass: none, or more than one, is reported rather than guessed between.
|
||||
|
||||
The two bytes between the lead and `fe 80` are the trigger source, a uint16
|
||||
BE bitmask: 0x01 Tran, 0x02 Vert, 0x04 Long, 0x08 MicL, 0x200 Manual --
|
||||
Blastware's Trigger on 6,493 / 6,493 DL2 waveforms (2026-11-03).
|
||||
"""
|
||||
if start is None or stop is None:
|
||||
return None, "the footer has no start and stop to check one against"
|
||||
return None, "the footer has no start and stop to check one against", None
|
||||
found, rejected = [], 0
|
||||
i = raw.find(_EVENT_RECORD_MARKER, 6)
|
||||
while 0 <= i and i + 18 <= end:
|
||||
@@ -921,15 +967,62 @@ def _embedded_event_record(
|
||||
<= _EVENT_RECORD_SLACK_S[1])
|
||||
)
|
||||
if valid:
|
||||
found.append(trig)
|
||||
found.append((trig, int.from_bytes(raw[i - 2:i], "big")))
|
||||
else:
|
||||
rejected += 1
|
||||
i = raw.find(_EVENT_RECORD_MARKER, i + 1)
|
||||
if len(found) == 1:
|
||||
return found[0], ""
|
||||
return found[0][0], "", found[0][1]
|
||||
if found:
|
||||
return None, f"{len(found)} candidates validate"
|
||||
return None, (f"{rejected} candidate(s), none valid" if rejected else "no candidate")
|
||||
return None, f"{len(found)} candidates validate", None
|
||||
return None, (f"{rejected} candidate(s), none valid" if rejected else "no candidate"), None
|
||||
|
||||
|
||||
# A histogram's event record: the same lead, the source 0x0400, marker fe f5,
|
||||
# then its start and stop -- Blastware's Histogram Start / Stop on 63,490 /
|
||||
# 63,490 DL2 histograms. On all 63,500 its start is 0 or 1 s after the footer's
|
||||
# start and its stop 0 or 1 s before the footer's stop (2026-11-03).
|
||||
_HISTOGRAM_RECORD_MARKER = b"\xfe\xf5"
|
||||
_HISTOGRAM_RECORD_SOURCE = b"\x04\x00"
|
||||
|
||||
|
||||
def interval_times(start: datetime.datetime, interval_sec: int,
|
||||
stop: Optional[datetime.datetime], n: int) -> list[datetime.datetime]:
|
||||
"""Each histogram interval's time as Blastware prints it: the interval's
|
||||
end, start + (i + 1) x interval, capped at the stop. 2,308,524 / 2,308,524
|
||||
DL2 rows; and an event's peak date and time are its interval's (2026-11-03)."""
|
||||
out = []
|
||||
for i in range(n):
|
||||
t = start + datetime.timedelta(seconds=interval_sec * (i + 1))
|
||||
out.append(min(t, stop) if stop is not None else t)
|
||||
return out
|
||||
|
||||
|
||||
def _histogram_event_record(
|
||||
raw: bytes, end: int, start: Optional[datetime.datetime],
|
||||
stop: Optional[datetime.datetime],
|
||||
) -> tuple[Optional[datetime.datetime], Optional[datetime.datetime], str]:
|
||||
"""(start, stop) from a histogram's own event record, or (None, None, why).
|
||||
Exactly one record may validate against the footer's start and stop."""
|
||||
if start is None or stop is None:
|
||||
return None, None, "the footer has no start and stop to check one against"
|
||||
found, rejected = [], 0
|
||||
i = raw.find(_HISTOGRAM_RECORD_MARKER, 6)
|
||||
while 0 <= i and i + 18 <= end:
|
||||
a, b = _ts8(raw[i + 2:i + 10]), _ts8(raw[i + 10:i + 18])
|
||||
if (raw[i - 6:i - 2] == _EVENT_RECORD_LEAD and raw[i - 2:i] == _HISTOGRAM_RECORD_SOURCE
|
||||
and a is not None and b is not None and a <= b
|
||||
and 0 <= (a - start).total_seconds() <= 1
|
||||
and 0 <= (stop - b).total_seconds() <= 1):
|
||||
found.append((a, b))
|
||||
elif raw[i - 6:i - 2] == _EVENT_RECORD_LEAD:
|
||||
rejected += 1
|
||||
i = raw.find(_HISTOGRAM_RECORD_MARKER, i + 1)
|
||||
if len(found) == 1:
|
||||
return found[0][0], found[0][1], ""
|
||||
if found:
|
||||
return None, None, f"{len(found)} candidates validate"
|
||||
return None, None, (f"{rejected} candidate(s), none valid" if rejected else "no candidate")
|
||||
|
||||
|
||||
def _parse_record_time_seconds(raw: bytes) -> Optional[float]:
|
||||
@@ -1047,6 +1140,83 @@ def _setup_geo_range(raw: bytes) -> tuple[Optional[int], Optional[str]]:
|
||||
return None, f"geophone range not read: channel range bytes {found}"
|
||||
|
||||
|
||||
# The identity block before the setup: what the live read gets from SUB FE
|
||||
# (DeviceInfo). Offsets back from k, the setup name; matched against every DL2
|
||||
# report 2026-11-03 -- serial, version and calibration 69,983 / 69,983, the
|
||||
# battery 69,729 plus 254 that Blastware rounds half up (6.25 -> "6.3 Volts").
|
||||
_SERIAL_BEFORE_NAME = 202 # ASCII, NUL-terminated
|
||||
_BATTERY_BEFORE_NAME = 190 # uint16 BE, hundredths of a volt
|
||||
_FIRMWARE_MINOR_BEFORE_NAME = 193 # 0x11 = 17 for S338.17, as SUB EA
|
||||
_FIRMWARE_BEFORE_NAME = 147 # "S338.17"
|
||||
_DSP_BEFORE_NAME = 138 # "10.72"
|
||||
_CALIBRATION_BEFORE_NAME = 132 # dd mm yyyy (BE)
|
||||
_CALIBRATED_BY_BEFORE_NAME = 128 # "Instantel"
|
||||
_MANUFACTURER_BEFORE_NAME = 94 # "Instantel"
|
||||
_MODEL_BEFORE_NAME = 72 # "MiniMate Plus" / "BlastMate III"
|
||||
|
||||
|
||||
def _cstr(raw: bytes, i: int, limit: int = 40) -> Optional[str]:
|
||||
if i < 0:
|
||||
return None
|
||||
j = raw.find(b"\x00", i, i + limit)
|
||||
s = raw[i:j if j >= 0 else i + limit].decode("ascii", errors="replace").strip()
|
||||
return s or None
|
||||
|
||||
|
||||
def _setup_identity(raw: bytes, k: int) -> tuple[Optional[DeviceInfo], Optional[float]]:
|
||||
"""(the unit's identity, the battery in volts) from the block before the
|
||||
setup name at k."""
|
||||
if k < _SERIAL_BEFORE_NAME:
|
||||
return None, None
|
||||
serial = _cstr(raw, k - _SERIAL_BEFORE_NAME, 16)
|
||||
if not serial:
|
||||
return None, None
|
||||
c = k - _CALIBRATION_BEFORE_NAME
|
||||
try:
|
||||
cal = datetime.date(int.from_bytes(raw[c + 2:c + 4], "big"), raw[c + 1], raw[c])
|
||||
except ValueError:
|
||||
cal = None
|
||||
info = DeviceInfo(
|
||||
serial=serial,
|
||||
firmware_minor=raw[k - _FIRMWARE_MINOR_BEFORE_NAME],
|
||||
firmware_version=_cstr(raw, k - _FIRMWARE_BEFORE_NAME, 9),
|
||||
dsp_version=_cstr(raw, k - _DSP_BEFORE_NAME, 6),
|
||||
manufacturer=_cstr(raw, k - _MANUFACTURER_BEFORE_NAME),
|
||||
model=_cstr(raw, k - _MODEL_BEFORE_NAME),
|
||||
calibration_date=cal,
|
||||
calibrated_by=_cstr(raw, k - _CALIBRATED_BY_BEFORE_NAME, 32),
|
||||
)
|
||||
b = k - _BATTERY_BEFORE_NAME
|
||||
return info, int.from_bytes(raw[b:b + 2], "big") / 100
|
||||
|
||||
|
||||
# Trigger settings, in Series IV's 0x1A layout again: the trigger-source bitmask
|
||||
# at k - 19 ([29]: 0x07 geophones, 0x08 mic), the stop mode at k - 31 ([17],
|
||||
# 0 = Fixed), and each channel block's trigger level, a float32 at label + 30 --
|
||||
# in/s for a geophone, psi for the mic. The mic block's type code at label + 4
|
||||
# is Series IV's (2 = linear). Against every DL2 waveform (2026-11-03): the geo
|
||||
# level 6,447 / 6,447, the mic level 4,403 / 4,403, and Blastware prints a level
|
||||
# exactly when its channel is a trigger source and the event was not Manual.
|
||||
_TRIGGER_SOURCES_BEFORE_NAME = 19
|
||||
_STOP_MODE_BEFORE_NAME = 31
|
||||
_TRIGGER_LEVEL_AFTER_LABEL = 30
|
||||
_MIC_TYPE_AFTER_LABEL = 4
|
||||
|
||||
|
||||
def _setup_trigger(raw: bytes, k: int) -> dict:
|
||||
out = {"trigger_sources": raw[k - _TRIGGER_SOURCES_BEFORE_NAME],
|
||||
"record_stop_mode": raw[k - _STOP_MODE_BEFORE_NAME]}
|
||||
t = raw.find(b"\x00\x00\x01Tran", k, k + _CHANNEL_BLOCK_SPAN)
|
||||
if t >= 0:
|
||||
p = t + 3 + _TRIGGER_LEVEL_AFTER_LABEL
|
||||
out["trigger_level_geo"] = struct.unpack_from(">f", raw, p)[0]
|
||||
m = raw.find(b"MicL", k, k + _CHANNEL_BLOCK_SPAN)
|
||||
if m >= 0:
|
||||
out["trigger_level_mic_psi"] = struct.unpack_from(">f", raw, m + _TRIGGER_LEVEL_AFTER_LABEL)[0]
|
||||
out["mic_type"] = int.from_bytes(raw[m + _MIC_TYPE_AFTER_LABEL:m + _MIC_TYPE_AFTER_LABEL + 4], "big")
|
||||
return out
|
||||
|
||||
|
||||
def read_blastware_file(path: Union[str, Path], *, name: Optional[str] = None) -> Event:
|
||||
"""Parse a Blastware event file into an Event: `decode_blastware_bytes` on its
|
||||
bytes, `name` defaulting to the file's own (see there -- never a time source)."""
|
||||
@@ -1195,8 +1365,10 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
|
||||
problems = []
|
||||
if record_type is None:
|
||||
problems.append(f"unknown record type byte 0x{type_byte:02x} at STRT[18]")
|
||||
hist_records = None
|
||||
if record_type == "Histogram":
|
||||
decoded = decode_histogram_body(body)
|
||||
hist_records = decode_histogram_body_full(body)
|
||||
decoded = channels_from_records(hist_records)
|
||||
is_waveform_body = False
|
||||
elif record_type == "Waveform":
|
||||
decoded = decode_waveform_v2(body)
|
||||
@@ -1205,7 +1377,8 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
|
||||
decoded = decode_waveform_v2(body)
|
||||
is_waveform_body = decoded is not None
|
||||
if decoded is None:
|
||||
decoded = decode_histogram_body(body)
|
||||
hist_records = decode_histogram_body_full(body)
|
||||
decoded = channels_from_records(hist_records)
|
||||
if decoded is None:
|
||||
log.warning(
|
||||
"%s: body codec failed to decode (body starts %s) — "
|
||||
@@ -1236,6 +1409,11 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
|
||||
ev.geo_range, range_problem = _setup_geo_range(raw)
|
||||
if range_problem:
|
||||
ev.decode_problems.append(range_problem + "; peaks assume the Normal range")
|
||||
k = _setup_name_at(raw)
|
||||
if k is not None:
|
||||
ev.device_info, ev.battery_volts = _setup_identity(raw, k)
|
||||
for attr, value in _setup_trigger(raw, k).items():
|
||||
setattr(ev, attr, value)
|
||||
if is_waveform_body:
|
||||
ev.rectime_seconds = _setup_record_time(raw)
|
||||
ev.total_samples = len(samples["Tran"]) or None
|
||||
@@ -1266,17 +1444,19 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
|
||||
# embedded in the 5A stream (_embedded_event_record), so a waveform takes
|
||||
# it from there. Without a validated one the estimate stands, reported as a
|
||||
# decode problem -- never a filename's time, which is only a cross-check.
|
||||
# Histograms stay on ts1 although it runs a second early on 97% (their
|
||||
# record, marker fe f5, holds the exact start): in Blastware's timing a
|
||||
# waveform and its histogram share a second 209 times in prod's store, and
|
||||
# events is unique on (serial, timestamp) -- #51.
|
||||
# A histogram's footer start runs a second early on 97%. Its own event
|
||||
# record (marker fe f5) holds Blastware's exact start and stop, so it takes
|
||||
# them from there (#51); events are keyed unit + time + type, so a waveform
|
||||
# and its histogram may share a second.
|
||||
# ⚠ RETRACTED 2026-11-03: "histograms stay on ts1" -- that held only while
|
||||
# events were unique on (serial, timestamp).
|
||||
if is_waveform_body and ts2 is not None:
|
||||
_stop = datetime.datetime(ts2.year, ts2.month, ts2.day,
|
||||
ts2.hour, ts2.minute, ts2.second)
|
||||
_rt = _parse_record_time_seconds(raw)
|
||||
_start = (datetime.datetime(ts1.year, ts1.month, ts1.day, ts1.hour, ts1.minute, ts1.second)
|
||||
if ts1 is not None else None)
|
||||
_trig, _why = _embedded_event_record(raw, footer_pos, _start, _stop, _rt)
|
||||
_trig, _why, ev.triggered_by = _embedded_event_record(raw, footer_pos, _start, _stop, _rt)
|
||||
if _trig is not None:
|
||||
ev.timestamp_source = "event_record"
|
||||
else:
|
||||
@@ -1298,13 +1478,25 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
|
||||
hour=_trig.hour, minute=_trig.minute, second=_trig.second,
|
||||
)
|
||||
elif ts1 is not None:
|
||||
_start, _hstop, _why = (_histogram_event_record(raw, footer_pos, ts1, ts2)
|
||||
if record_type == "Histogram" else (None, None, ""))
|
||||
if _start is not None:
|
||||
ev.timestamp_source = "event_record"
|
||||
ev.stop_time = _hstop
|
||||
else:
|
||||
_start = ts1
|
||||
ev.timestamp_source = "footer"
|
||||
if record_type == "Histogram":
|
||||
_problem = (f"no validated histogram event record ({_why}); the start is the "
|
||||
"footer's, a second early on 97% of measured files")
|
||||
ev.decode_problems.append(_problem)
|
||||
log.warning("%s: %s", label, _problem)
|
||||
ev.timestamp = Timestamp(
|
||||
raw=footer[2:10],
|
||||
flag=0x10,
|
||||
year=ts1.year, unknown_byte=0, month=ts1.month, day=ts1.day,
|
||||
hour=ts1.hour, minute=ts1.minute, second=ts1.second,
|
||||
year=_start.year, unknown_byte=0, month=_start.month, day=_start.day,
|
||||
hour=_start.hour, minute=_start.minute, second=_start.second,
|
||||
)
|
||||
ev.timestamp_source = "footer"
|
||||
|
||||
ev.project_info = _setup_notes(raw)
|
||||
ev.raw_samples = samples
|
||||
@@ -1327,14 +1519,32 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
|
||||
# The geophone full scale is the file's range; Normal when it wasn't read.
|
||||
geo_fs = _GEO_FS_BY_RANGE.get(ev.geo_range, _GEO_NORMAL_FS_INS)
|
||||
ev.peak_values = _peaks_from_samples(samples, geo_fs) if has_samples else None
|
||||
if not is_waveform_body and ev.peak_values is not None:
|
||||
# A histogram stores each interval's vector sum (squared); the event's
|
||||
# is the largest. Combining the channel peaks instead read high on 86%
|
||||
# of DL2's histograms -- they can come from different moments.
|
||||
pvs = interval_pvs(body)
|
||||
if pvs:
|
||||
ev.peak_values.peak_vector_sum = (
|
||||
max(pvs) * _HIST_GEO_COUNTS_PER_UNIT * geo_fs / _GEO_INT16_FS)
|
||||
if (is_waveform_body and ev.peak_values is not None and ev.sample_rate
|
||||
and ev.pretrig_samples is not None):
|
||||
_waveform_peak_detail(ev.peak_values, samples, geo_fs, ev.sample_rate, ev.pretrig_samples)
|
||||
if ev.stop_time is None: # a histogram's record stop, else the footer's
|
||||
ev.stop_time = ts2
|
||||
if hist_records:
|
||||
# A histogram stores each interval's vector sum (squared), and each
|
||||
# channel's half-period: Blastware's per-interval Geo PVS (771,354 /
|
||||
# 771,354 DL2 cells) and frequency, (sample rate / 2) / half-period.
|
||||
unit_ins = _HIST_GEO_COUNTS_PER_UNIT * geo_fs / _GEO_INT16_FS
|
||||
ev.interval_pvs = [math.sqrt(r["pvs_sq"]) * unit_ins for r in hist_records]
|
||||
ev.interval_half_periods = {
|
||||
ch: [r[key] for r in hist_records if r[key] is not None]
|
||||
for ch, key in (("Tran", "t_halfp"), ("Vert", "v_halfp"),
|
||||
("Long", "l_halfp"), ("MicL", "m_halfp"))}
|
||||
if not ev.interval_half_periods["MicL"]:
|
||||
del ev.interval_half_periods["MicL"]
|
||||
k = _setup_name_at(raw)
|
||||
if k is not None and k >= _INTERVAL_BEFORE_NAME:
|
||||
ev.histogram_interval_sec = int.from_bytes(
|
||||
raw[k - _INTERVAL_BEFORE_NAME:k - _INTERVAL_BEFORE_NAME + 2], "big") or None
|
||||
if not is_waveform_body and ev.peak_values is not None and ev.interval_pvs:
|
||||
# The event's vector sum is the largest interval's. Combining the
|
||||
# channel peaks instead read high on 86% of DL2's histograms -- they
|
||||
# can come from different moments.
|
||||
ev.peak_values.peak_vector_sum = max(ev.interval_pvs)
|
||||
ev._a5_frames = None # not recoverable from BW file
|
||||
|
||||
return ev
|
||||
@@ -156,10 +156,11 @@ _BLOCK_MARKER = 10
|
||||
# 16-count-unit output (1 unit = 0.005 in/s = 16 ADC counts).
|
||||
_GEO_LSB_INS = 0.005
|
||||
|
||||
# Frequency formula: freq_Hz = _FREQ_NUMERATOR / half_period_samples.
|
||||
# Empirically determined to be 512 (= sample_rate / 2, where sample rate
|
||||
# is 1024 sps for the standard MiniMate Plus configuration).
|
||||
_FREQ_NUMERATOR = 512
|
||||
# Frequency formula: freq_Hz = (sample_rate / 2) / half_period_samples.
|
||||
# ⚠ RETRACTED 2026-11-03 (#50): "a fixed numerator of 512". 512 is sample_rate
|
||||
# / 2 at 1024 sps only; at 2048 sps it halved every frequency. Measured on DL2:
|
||||
# 527,915 / 527,915 cells at 1024 sps and 1,725 / 1,725 at 2048.
|
||||
_FREQ_NUMERATOR = 512 # sample_rate / 2 at the default 1024 sps
|
||||
|
||||
|
||||
def _is_data_block(block: bytes) -> bool:
|
||||
@@ -300,7 +301,11 @@ def decode_histogram_body(body: bytes) -> Optional[dict]:
|
||||
to get 1-count ADC values, then ``count / 32767 * 10.0`` for in/s)
|
||||
- Mic channel: use ``waveform_codec.mic_count_to_db(count)``
|
||||
"""
|
||||
records = _walk_auto(body)
|
||||
return channels_from_records(_walk_auto(body))
|
||||
|
||||
|
||||
def channels_from_records(records: Optional[List[dict]]) -> Optional[dict]:
|
||||
"""``decode_histogram_body``'s per-channel peaks, from records already walked."""
|
||||
if not records:
|
||||
return None
|
||||
return {
|
||||
@@ -338,17 +343,19 @@ def interval_pvs(body: bytes) -> Optional[List[float]]:
|
||||
return [math.sqrt(r["pvs_sq"]) for r in records] if records else None
|
||||
|
||||
|
||||
def half_period_to_hz(halfp: int) -> Optional[float]:
|
||||
"""Convert a half-period in samples to frequency in Hz.
|
||||
def half_period_to_hz(halfp: int, sample_rate: int = 1024) -> Optional[float]:
|
||||
"""Convert a half-period in samples to frequency in Hz:
|
||||
``(sample_rate / 2) / halfp``.
|
||||
|
||||
Returns ``None`` for half-period ≤ 5 — the device emits values in
|
||||
that range when the measured zero-crossing rate exceeds 100 Hz
|
||||
(the BW display reports `>100 Hz` for such cases). Callers can
|
||||
treat ``None`` as the `>100 Hz` sentinel.
|
||||
that range when the measured zero-crossing rate exceeds 100 Hz at
|
||||
1024 sps (the BW display reports `>100`, `>200` at 2048 sps). Callers
|
||||
can treat ``None`` as that sentinel. A half-period of 0 is Blastware's
|
||||
"N/A"; it also returns None.
|
||||
"""
|
||||
if halfp <= 5:
|
||||
return None
|
||||
return _FREQ_NUMERATOR / halfp
|
||||
return (sample_rate / 2) / halfp
|
||||
|
||||
|
||||
def geo_count_to_ins(count: int) -> float:
|
||||
|
||||
@@ -300,6 +300,10 @@ class DeviceInfo:
|
||||
# ── From SUB 08 (EVENT_INDEX_RESPONSE) ────────────────────────────────────
|
||||
event_count: Optional[int] = None # stored event count from F7 response 🔶
|
||||
|
||||
# ── From a Blastware event file's identity block (2026-11-03) ─────────────
|
||||
calibration_date: Optional[datetime.date] = None # e.g. 2019-02-20 ✅
|
||||
calibrated_by: Optional[str] = None # e.g. "Instantel" ✅
|
||||
|
||||
def __str__(self) -> str:
|
||||
fw = self.firmware_version or f"?.{self.firmware_minor}"
|
||||
mdl = self.model or "MiniMate Plus"
|
||||
@@ -360,6 +364,15 @@ class PeakValues:
|
||||
vert_zc_above_range: bool = False
|
||||
long_zc_above_range: bool = False
|
||||
mic_zc_above_range: bool = False
|
||||
# A waveform's peak detail, from its samples (2026-11-04); None for a histogram.
|
||||
tran_time_of_peak: Optional[float] = None # s from the trigger; negative = pre-trigger
|
||||
vert_time_of_peak: Optional[float] = None
|
||||
long_time_of_peak: Optional[float] = None
|
||||
micl_time_of_peak: Optional[float] = None
|
||||
pvs_time: Optional[float] = None # s from the trigger, of the vector-sum peak
|
||||
tran_peak_accel_g: Optional[float] = None
|
||||
vert_peak_accel_g: Optional[float] = None
|
||||
long_peak_accel_g: Optional[float] = None
|
||||
|
||||
|
||||
# ── Project / operator metadata ───────────────────────────────────────────────
|
||||
@@ -548,6 +561,20 @@ class Event:
|
||||
# Geophone range from the recording setup, as ComplianceConfig.geo_range:
|
||||
# 0 Normal (10 in/s full scale), 1 Sensitive (1.25 in/s). None: not read.
|
||||
geo_range: Optional[int] = None
|
||||
# From a Blastware event file (2026-11-03); None when not read.
|
||||
device_info: Optional["DeviceInfo"] = None # the unit, as SUB FE reports it
|
||||
battery_volts: Optional[float] = None # at the event
|
||||
triggered_by: Optional[int] = None # 0x01 Tran 0x02 Vert 0x04 Long 0x08 MicL 0x200 Manual
|
||||
trigger_sources: Optional[int] = None # setup bitmask: 0x07 geophones, 0x08 mic
|
||||
trigger_level_geo: Optional[float] = None # in/s, as ComplianceConfig.trigger_level_geo
|
||||
trigger_level_mic_psi: Optional[float] = None
|
||||
record_stop_mode: Optional[int] = None # 0 = Fixed
|
||||
mic_type: Optional[int] = None # 2 = Linear Weighting (as Series IV)
|
||||
stop_time: Optional[datetime.datetime] = None # the footer's stop
|
||||
# A histogram's per-interval detail (2026-11-03); None for a waveform.
|
||||
histogram_interval_sec: Optional[int] = None # as ComplianceConfig.histogram_interval_sec
|
||||
interval_half_periods: Optional[dict] = None # channel -> half-period per interval, samples
|
||||
interval_pvs: Optional[list] = None # each interval's vector sum, in/s
|
||||
|
||||
# Sensor self-check traces keyed by channel label — the short diagnostic
|
||||
# waveforms the unit records when it pulses each sensor before monitoring
|
||||
|
||||
+80
-12
@@ -142,9 +142,14 @@ _WRITE_TAIL = {SUB_EVENT_INDEX_WRITE: b"\x02\x00", SUB_TRIGGER_CONFIG_WRITE: b"\
|
||||
SUB_CALL_HOME_WRITE: b"\x00\x00"}
|
||||
|
||||
|
||||
def write_image(sub: int, data: bytes) -> bytes:
|
||||
def write_image(sub: int, data: bytes, *, escaped: bool = True) -> bytes:
|
||||
"""The whole block a write sends: `data` unescaped, N + 2 bytes.
|
||||
|
||||
`escaped=False`: `data` is already logical (every block read since phase 5 --
|
||||
read_event_index, read_compliance_content, read_trigger_config,
|
||||
read_waveform_data_raw -- returns unescaped bytes), so it is NOT unescaped
|
||||
again: a logical `10 02` (job number 4098) would otherwise collapse.
|
||||
|
||||
A config block starts with its own length N (uint16 BE) and is written as N
|
||||
bytes plus two -- on every Blastware write on record. `data` may be the
|
||||
block as a read returned it (N bytes, or N + 2) and may still hold the
|
||||
@@ -152,7 +157,7 @@ def write_image(sub: int, data: bytes) -> bytes:
|
||||
Anything else is refused before a byte is sent: a block one byte longer than
|
||||
its header says is what an edit beside a kept escape byte leaves behind.
|
||||
"""
|
||||
image = unescape_reply(bytes(data))
|
||||
image = unescape_reply(bytes(data)) if escaped else bytes(data)
|
||||
if len(image) < 2:
|
||||
raise ValueError(f"write SUB 0x{sub:02X}: {len(image)} bytes is not a whole block")
|
||||
n = int.from_bytes(image[:2], "big")
|
||||
@@ -169,6 +174,45 @@ class ImageRefused(ValueError):
|
||||
"""A write refused before any byte was sent: the image is not a whole block."""
|
||||
|
||||
|
||||
# ── The settings block (SUB 1A), as content ─────────────────────────────────
|
||||
#
|
||||
# Measured 2026-11-03 on BE9441's 10-26 recording (12 reads, both Blastware's
|
||||
# 4 x 512 + 42 pattern and SFM's 1024 + 1024 + 42): unescape each data frame and
|
||||
# take data[11:]; every frame but the last then starts with one `00` that is not
|
||||
# content. Dropped, the frames join into 2,090 bytes that start with their own
|
||||
# length N = 2090 -- Series IV's 0x1A content layout -- and the read after each
|
||||
# of Blastware's two writes equals the image it had just written.
|
||||
# tests/test_s3_settings_read.py.
|
||||
|
||||
COMPLIANCE_CONTENT_LEN = 2090
|
||||
# SFM's 1A read: (offset = the content length asked for, page) per data frame.
|
||||
_COMPLIANCE_READ_STEPS = ((0x0400, 0x00), (0x0400, 0x04), (0x002A, 0x08))
|
||||
|
||||
|
||||
def assemble_compliance_content(frames: "list[bytes]", lengths: "Optional[tuple]" = None) -> bytes:
|
||||
"""Join a 1A read's data frames (each S3Frame.data, kept escapes and all, in
|
||||
order) into the logical settings block. Judges nothing: a monitoring unit's
|
||||
device-info answer assembles too -- `is_compliance_content` tells them apart.
|
||||
|
||||
`lengths`: the content each frame was asked for (SFM's read: 1024, 1024, 42).
|
||||
Each frame then gives exactly that. Measured at the bench 2026-11-04 (BE9441):
|
||||
when a frame's checksum byte is itself escaped (02 / 03 / 04), the parser keeps
|
||||
the escape's 0x10 and strips only the byte after it, so the frame arrives one
|
||||
byte long, ending in a lone 0x10. That one byte is dropped; any other leftover
|
||||
is kept, and the block then fails is_compliance_content."""
|
||||
parts = [unescape_reply(bytes(f))[11:] for f in frames]
|
||||
parts = [p[1:] for p in parts[:-1]] + parts[-1:]
|
||||
if lengths is not None and len(lengths) == len(parts):
|
||||
parts = [p[:n] if p[n:] == b"\x10" else p for p, n in zip(parts, lengths)]
|
||||
return b"".join(parts)
|
||||
|
||||
|
||||
def is_compliance_content(block: bytes) -> bool:
|
||||
"""Whether `block` is the settings block: 2,090 bytes headed by N = 2090."""
|
||||
return (len(block) == COMPLIANCE_CONTENT_LEN
|
||||
and int.from_bytes(block[0:2], "big") == COMPLIANCE_CONTENT_LEN)
|
||||
|
||||
|
||||
def is_call_home_block(raw: bytes) -> bool:
|
||||
"""Whether a 0x2C reply payload is the call-home block: it starts with its own
|
||||
length N = 0x7C (00 7C DC on every read on record) and is N (or N + 2) bytes
|
||||
@@ -589,6 +633,10 @@ class MiniMateProtocol:
|
||||
data_rsp = self._recv_one(expected_sub=rsp_sub)
|
||||
|
||||
raw = unescape_reply(data_rsp.data)[11:] # unescaped, as read_event_index
|
||||
# An escaped checksum byte leaves its 0x10 behind (bench 2026-11-04; see
|
||||
# assemble_compliance_content): one stray byte beyond what was asked is dropped.
|
||||
if len(raw) == length + 1 and raw[-1:] == b"\x10":
|
||||
raw = raw[:-1]
|
||||
log.debug("read_waveform_data_raw: got %d bytes", len(raw))
|
||||
return raw
|
||||
|
||||
@@ -1029,6 +1077,25 @@ class MiniMateProtocol:
|
||||
|
||||
return bytes(config)
|
||||
|
||||
def read_compliance_content(self) -> bytes:
|
||||
"""The 1A read as the logical settings block (see assemble_compliance_content).
|
||||
|
||||
The same requests as read_compliance_config -- probe, then B / C / D -- but
|
||||
strict: a data frame that does not arrive raises, and there is no tail
|
||||
drain, so a short read is never assembled. Returns whatever assembled,
|
||||
unjudged; a MONITORING unit answers with its device-info block, which
|
||||
is_compliance_content() rejects.
|
||||
"""
|
||||
rsp_sub = _expected_rsp_sub(SUB_COMPLIANCE)
|
||||
self._send(build_bw_frame(SUB_COMPLIANCE, 0, bytes([0, 0, 0, 0, 0, 0, 0, 0x64, 0, 0])))
|
||||
self._recv_one(expected_sub=rsp_sub)
|
||||
frames = []
|
||||
for offset, page in _COMPLIANCE_READ_STEPS:
|
||||
self._send(build_bw_frame(SUB_COMPLIANCE, offset,
|
||||
bytes([0, 0, page, 0, 0, 0, 0, 0x64, 0, 0])))
|
||||
frames.append(self._recv_one(expected_sub=rsp_sub).data)
|
||||
return assemble_compliance_content(frames, lengths=tuple(o for o, _ in _COMPLIANCE_READ_STEPS))
|
||||
|
||||
# ── Write commands (SUBs 68–83) ───────────────────────────────────────────
|
||||
|
||||
def recv_write_ack(
|
||||
@@ -1086,25 +1153,26 @@ class MiniMateProtocol:
|
||||
self._send(frame)
|
||||
return self.recv_write_ack(expected_sub=rsp_sub)
|
||||
|
||||
def _write_block(self, sub: int, data: bytes, params: bytes = bytes(10)) -> S3Frame:
|
||||
def _write_block(self, sub: int, data: bytes, params: bytes = bytes(10), *,
|
||||
escaped: bool = True) -> S3Frame:
|
||||
"""Send one config block as a write and return its ack (0xFF - sub)."""
|
||||
image = write_image(sub, data)
|
||||
image = write_image(sub, data, escaped=escaped)
|
||||
frame = build_bw_write_frame(sub, image, params=params)
|
||||
log.debug("write SUB=0x%02X: %d-byte image", sub, len(image))
|
||||
self._send(frame)
|
||||
return self.recv_write_ack(expected_sub=_expected_rsp_sub(sub))
|
||||
|
||||
def write_event_index(self, data: bytes) -> S3Frame:
|
||||
def write_event_index(self, data: bytes, *, escaped: bool = True) -> S3Frame:
|
||||
"""SUB 68: write the event-index block (as SUB 08 read it). Ack 0x97;
|
||||
callers follow with write_confirm(SUB_WRITE_CONFIRM_B). See write_image."""
|
||||
return self._write_block(SUB_EVENT_INDEX_WRITE, data)
|
||||
return self._write_block(SUB_EVENT_INDEX_WRITE, data, escaped=escaped)
|
||||
|
||||
def write_waveform_data(self, data: bytes) -> S3Frame:
|
||||
def write_waveform_data(self, data: bytes, *, escaped: bool = True) -> S3Frame:
|
||||
"""SUB 69: write the waveform-data block (as SUB 09 read it). Ack 0x96;
|
||||
callers follow with write_confirm C then A. See write_image."""
|
||||
return self._write_block(SUB_WAVEFORM_DATA_WRITE, data)
|
||||
return self._write_block(SUB_WAVEFORM_DATA_WRITE, data, escaped=escaped)
|
||||
|
||||
def write_compliance_config_raw(self, data: bytes) -> None:
|
||||
def write_compliance_config_raw(self, data: bytes, *, escaped: bool = True) -> None:
|
||||
"""SUB 71: write the compliance image in addressed chunks, then confirm (72).
|
||||
|
||||
Measured: the image is 2,092 bytes (its header N = 2,090, plus 2), sent as
|
||||
@@ -1115,7 +1183,7 @@ class MiniMateProtocol:
|
||||
both. (Retracted: "exactly 3 chunks, offset 0x1004, params 00 00 00 10 04"
|
||||
-- the length 0x0400 and address 0x0400, read with their escape bytes.)
|
||||
"""
|
||||
image = write_image(SUB_COMPLIANCE_WRITE, data)
|
||||
image = write_image(SUB_COMPLIANCE_WRITE, data, escaped=escaped)
|
||||
rsp_sub = _expected_rsp_sub(SUB_COMPLIANCE_WRITE)
|
||||
for addr in range(0, len(image), _COMPLIANCE_CHUNK):
|
||||
params = bytes([0x00, 0x00, (addr >> 8) & 0xFF, addr & 0xFF]) + bytes(6)
|
||||
@@ -1126,10 +1194,10 @@ class MiniMateProtocol:
|
||||
self.recv_write_ack(expected_sub=rsp_sub)
|
||||
self.write_confirm(SUB_WRITE_CONFIRM_A)
|
||||
|
||||
def write_trigger_config(self, data: bytes) -> S3Frame:
|
||||
def write_trigger_config(self, data: bytes, *, escaped: bool = True) -> S3Frame:
|
||||
"""SUB 82: write the trigger block (as SUB 0x2E read it). Ack 0x7D;
|
||||
callers follow with write_confirm(SUB_TRIGGER_CONFIRM). See write_image."""
|
||||
return self._write_block(SUB_TRIGGER_CONFIG_WRITE, data)
|
||||
return self._write_block(SUB_TRIGGER_CONFIG_WRITE, data, escaped=escaped)
|
||||
|
||||
def read_trigger_config(self) -> bytes:
|
||||
"""SUB 0x2E two-step read: the 26-byte trigger block that SUB 82 writes.
|
||||
|
||||
@@ -1,68 +0,0 @@
|
||||
"""
|
||||
poc_set_project.py — POC test for set_project_info() against a live MiniMate Plus.
|
||||
|
||||
Usage:
|
||||
python poc_set_project.py [--host IP] [--port PORT]
|
||||
|
||||
Default target: BE11529 at 63.43.212.232:9034
|
||||
"""
|
||||
|
||||
import argparse
|
||||
import logging
|
||||
import sys
|
||||
|
||||
logging.basicConfig(
|
||||
level=logging.DEBUG,
|
||||
format="%(asctime)s %(levelname)-7s %(name)s %(message)s",
|
||||
datefmt="%H:%M:%S",
|
||||
)
|
||||
log = logging.getLogger("poc_set_project")
|
||||
|
||||
from minimateplus import MiniMateClient
|
||||
from minimateplus.transport import TcpTransport
|
||||
|
||||
|
||||
DEFAULT_HOST = "63.43.212.232"
|
||||
DEFAULT_PORT = 9034
|
||||
|
||||
|
||||
def main() -> None:
|
||||
ap = argparse.ArgumentParser(description="POC: write project info to MiniMate Plus")
|
||||
ap.add_argument("--host", default=DEFAULT_HOST, help="Modem IP address")
|
||||
ap.add_argument("--port", type=int, default=DEFAULT_PORT, help="TCP port")
|
||||
ap.add_argument("--project", default="POC Write Test")
|
||||
ap.add_argument("--client-name", default="Terra-Mechanics Inc.")
|
||||
ap.add_argument("--operator", default="B. Harrison")
|
||||
ap.add_argument("--seis-loc", default="Lab Bench - POC")
|
||||
ap.add_argument("--notes", default="set_project_info POC 2026-04-07")
|
||||
args = ap.parse_args()
|
||||
|
||||
log.info("Connecting to %s:%d", args.host, args.port)
|
||||
transport = TcpTransport(args.host, port=args.port)
|
||||
|
||||
with MiniMateClient(transport=transport, timeout=60.0) as client:
|
||||
log.info("Performing POLL handshake + identity read …")
|
||||
info = client.connect()
|
||||
log.info("Connected: serial=%s firmware=%s", info.serial, info.firmware_version)
|
||||
|
||||
log.info("Calling set_project_info() …")
|
||||
client.set_project_info(
|
||||
project=args.project,
|
||||
client_name=args.client_name,
|
||||
operator=args.operator,
|
||||
seis_loc=args.seis_loc,
|
||||
notes=args.notes,
|
||||
)
|
||||
log.info("set_project_info() returned — write sequence complete")
|
||||
|
||||
log.info("Done. Reconnect Blastware to verify the fields were written.")
|
||||
|
||||
|
||||
if __name__ == "__main__":
|
||||
try:
|
||||
main()
|
||||
except KeyboardInterrupt:
|
||||
sys.exit(0)
|
||||
except Exception as exc:
|
||||
log.exception("Fatal: %s", exc)
|
||||
sys.exit(1)
|
||||
+1
-1
@@ -4,7 +4,7 @@ build-backend = "setuptools.build_meta"
|
||||
|
||||
[project]
|
||||
name = "seismo-relay"
|
||||
version = "0.33.0"
|
||||
version = "0.34.0"
|
||||
description = "Python client and REST server for MiniMate Plus seismographs"
|
||||
requires-python = ">=3.10"
|
||||
dependencies = [
|
||||
|
||||
@@ -73,7 +73,7 @@ def main(argv: list[str] | None = None) -> int:
|
||||
conn.row_factory = sqlite3.Row
|
||||
|
||||
rows = list(conn.execute(
|
||||
"SELECT id, serial, timestamp, blastware_filename "
|
||||
"SELECT id, serial, timestamp, record_type, blastware_filename "
|
||||
" FROM events "
|
||||
" WHERE serial = 'UNKNOWN' "
|
||||
" ORDER BY timestamp",
|
||||
@@ -98,10 +98,11 @@ def main(argv: list[str] | None = None) -> int:
|
||||
unresolved += 1
|
||||
continue
|
||||
|
||||
# Check for an existing row at the target (serial, timestamp).
|
||||
# Check for an existing row at the target key (serial, timestamp,
|
||||
# record_type -- #51).
|
||||
existing = conn.execute(
|
||||
"SELECT id FROM events WHERE serial = ? AND timestamp = ?",
|
||||
(new_serial, ts),
|
||||
"SELECT id FROM events WHERE serial = ? AND timestamp = ? AND record_type IS ?",
|
||||
(new_serial, ts, row["record_type"]),
|
||||
).fetchone()
|
||||
action: str
|
||||
if existing is None:
|
||||
|
||||
+77
-22
@@ -36,6 +36,7 @@ from __future__ import annotations
|
||||
import datetime
|
||||
import json
|
||||
import logging
|
||||
import re
|
||||
import sqlite3
|
||||
import uuid
|
||||
from pathlib import Path
|
||||
@@ -107,7 +108,7 @@ CREATE TABLE IF NOT EXISTS events (
|
||||
shape_offset_pre REAL, -- pre-trigger baseline median (in/s)
|
||||
shape_offset_spread REAL, -- max(pre,mid,end) - min(...) in in/s; small = constant/DC
|
||||
created_at TEXT NOT NULL DEFAULT (strftime('%Y-%m-%dT%H:%M:%SZ', 'now')),
|
||||
UNIQUE(serial, timestamp)
|
||||
UNIQUE(serial, timestamp, record_type) -- unit + time + type (#51); see Migration 3
|
||||
);
|
||||
CREATE INDEX IF NOT EXISTS idx_events_serial ON events(serial);
|
||||
CREATE INDEX IF NOT EXISTS idx_events_timestamp ON events(timestamp);
|
||||
@@ -194,7 +195,7 @@ class SeismoDb:
|
||||
row = conn.execute(
|
||||
"SELECT sql FROM sqlite_master WHERE type='table' AND name='events'"
|
||||
).fetchone()
|
||||
if row and "UNIQUE(serial, timestamp)" not in row[0]:
|
||||
if row and "UNIQUE(serial, timestamp" not in row[0]: # neither key form yet
|
||||
log.info("_migrate: rebuilding events table — UNIQUE(serial, timestamp)")
|
||||
conn.executescript("""
|
||||
ALTER TABLE events RENAME TO events_old;
|
||||
@@ -348,6 +349,33 @@ class SeismoDb:
|
||||
""")
|
||||
log.info("_migrate: monitor_log table rebuilt OK")
|
||||
|
||||
# Migration 3 (#51, 2026-11-03): events UNIQUE (serial, timestamp) ->
|
||||
# (serial, timestamp, record_type). A unit records a waveform and a
|
||||
# histogram in the same second legitimately -- 209 times in prod's
|
||||
# 2026-09-30 store once histograms carry Blastware's start -- and the old
|
||||
# key could hold only one. The table is rebuilt from its own current
|
||||
# definition with only the key swapped, so every column added by the
|
||||
# migrations above, every row and every id is kept (Terra-View reads
|
||||
# rows by id); its indexes are recreated. One transaction.
|
||||
row = conn.execute(
|
||||
"SELECT sql FROM sqlite_master WHERE type='table' AND name='events'"
|
||||
).fetchone()
|
||||
if row and "UNIQUE(serial, timestamp)" in row[0]:
|
||||
log.info("_migrate: rebuilding events table — UNIQUE(serial, timestamp, record_type)")
|
||||
indexes = [r[0] for r in conn.execute(
|
||||
"SELECT sql FROM sqlite_master WHERE type='index' AND tbl_name='events' "
|
||||
"AND sql IS NOT NULL")]
|
||||
table = re.sub(r'^CREATE TABLE\s+("?)events\1', "CREATE TABLE events_rekeyed",
|
||||
row[0].replace("UNIQUE(serial, timestamp)",
|
||||
"UNIQUE(serial, timestamp, record_type)", 1))
|
||||
conn.executescript("BEGIN;\n" + table + ";\n"
|
||||
"INSERT INTO events_rekeyed SELECT * FROM events;\n"
|
||||
"DROP TABLE events;\n"
|
||||
"ALTER TABLE events_rekeyed RENAME TO events;\n"
|
||||
+ "".join(sql + ";\n" for sql in indexes)
|
||||
+ "COMMIT;")
|
||||
log.info("_migrate: events table re-keyed OK (%d indexes recreated)", len(indexes))
|
||||
|
||||
@staticmethod
|
||||
def _iso(dt: Optional[datetime.datetime]) -> Optional[str]:
|
||||
return dt.isoformat() if dt is not None else None
|
||||
@@ -507,7 +535,8 @@ class SeismoDb:
|
||||
device_family: Optional[str] = None,
|
||||
) -> tuple[int, int]:
|
||||
"""
|
||||
Insert triggered events. Silently skips duplicates (serial+timestamp).
|
||||
Insert triggered events. Silently skips duplicates (serial + timestamp +
|
||||
record_type: a waveform and a histogram may share a second, #51).
|
||||
Returns (inserted, skipped).
|
||||
|
||||
``waveform_records`` (optional): dict keyed by event waveform_key (hex)
|
||||
@@ -515,7 +544,7 @@ class SeismoDb:
|
||||
{"filename": str, "filesize": int, "a5_pickle_filename": str}
|
||||
|
||||
For events whose key is in this dict, the matching columns are
|
||||
populated. If a row with the same (serial, timestamp) already exists
|
||||
populated. If a row with the same (serial, timestamp, record_type) already exists
|
||||
(dedup hit), the matching waveform record is upserted onto the
|
||||
existing row so a re-download via the live endpoint refreshes the
|
||||
file metadata.
|
||||
@@ -558,18 +587,27 @@ class SeismoDb:
|
||||
# No validated event record: the time may be a second off,
|
||||
# so it is never allowed to move, merge into or duplicate
|
||||
# a row (_estimate_guard). The file is already stored.
|
||||
why = self._estimate_guard(conn, serial, rec.get("filename"), ts)
|
||||
why = self._estimate_guard(conn, serial, rec.get("filename"), ts,
|
||||
ev.record_type)
|
||||
if why:
|
||||
log.warning("insert_events: %s %s: %s", serial,
|
||||
rec.get("filename") or key, why)
|
||||
skipped += 1
|
||||
continue
|
||||
elif rec.get("filename") and ts and \
|
||||
self._restamp_by_file(conn, serial, rec["filename"], ts) is False:
|
||||
self._restamp_by_file(conn, serial, rec["filename"], ts,
|
||||
ev.record_type) is False:
|
||||
skipped += 1
|
||||
continue
|
||||
|
||||
try:
|
||||
if ev.record_type is None and conn.execute(
|
||||
"SELECT 1 FROM events WHERE serial = ? AND timestamp = ? "
|
||||
"AND record_type IS NULL", (serial, ts)).fetchone():
|
||||
# A UNIQUE key treats NULLs as distinct, so an untyped
|
||||
# event would never collide: it still refreshes the
|
||||
# untyped row at its second, as under the old key.
|
||||
raise sqlite3.IntegrityError("untyped event already stored")
|
||||
conn.execute(
|
||||
"""
|
||||
INSERT INTO events
|
||||
@@ -629,7 +667,7 @@ class SeismoDb:
|
||||
inserted += 1
|
||||
except sqlite3.IntegrityError:
|
||||
skipped += 1
|
||||
# UPSERT path: a row for this (serial, timestamp) already
|
||||
# UPSERT path: a row for this (serial, timestamp, record_type) already
|
||||
# exists. Refresh every device-authoritative field from
|
||||
# the new data so that a re-import with better data (e.g.
|
||||
# a watcher re-forward where the previous attempt missed
|
||||
@@ -682,7 +720,7 @@ class SeismoDb:
|
||||
shape_offset_axis = COALESCE(?, shape_offset_axis),
|
||||
shape_offset_pre = COALESCE(?, shape_offset_pre),
|
||||
shape_offset_spread = COALESCE(?, shape_offset_spread)
|
||||
WHERE serial = ? AND timestamp = ?
|
||||
WHERE serial = ? AND timestamp = ? AND record_type IS ?
|
||||
""",
|
||||
(
|
||||
pv.tran if pv else None,
|
||||
@@ -719,6 +757,7 @@ class SeismoDb:
|
||||
rec.get("shape_offset_spread") if rec else None,
|
||||
serial,
|
||||
ts,
|
||||
ev.record_type,
|
||||
),
|
||||
)
|
||||
|
||||
@@ -728,11 +767,11 @@ class SeismoDb:
|
||||
|
||||
@staticmethod
|
||||
def _estimate_guard(conn: sqlite3.Connection, serial: str, filename: Optional[str],
|
||||
ts: Optional[str]) -> Optional[str]:
|
||||
ts: Optional[str], record_type: Optional[str] = None) -> Optional[str]:
|
||||
"""Why an event whose time is only an estimate must not be written, or None.
|
||||
|
||||
An estimate (the decoder found no validated event record) may be a
|
||||
second off, and (serial, timestamp) is the table's key. So it never
|
||||
second off, and (serial, timestamp, record_type) is the table's key. So it never
|
||||
moves a row, never lands on another event's row, and never adds a second
|
||||
row for an event already stored -- each refusal is logged by the caller,
|
||||
and the event's file and sidecar are already in the store. Its own
|
||||
@@ -747,8 +786,8 @@ class SeismoDb:
|
||||
return (f"already stored under {', '.join(str(t) for t in own)}; its estimated "
|
||||
f"time {ts} does not move or duplicate it")
|
||||
holder = conn.execute(
|
||||
"SELECT blastware_filename FROM events WHERE serial = ? AND timestamp = ?",
|
||||
(serial, ts)).fetchone()
|
||||
"SELECT blastware_filename FROM events WHERE serial = ? AND timestamp = ? "
|
||||
"AND record_type IS ?", (serial, ts, record_type)).fetchone()
|
||||
if holder is not None and (named is None or holder[0] != named):
|
||||
return (f"its estimated time {ts} is held by {holder[0] or 'another event'}; "
|
||||
"not merged into it")
|
||||
@@ -756,8 +795,9 @@ class SeismoDb:
|
||||
|
||||
@staticmethod
|
||||
def _restamp_by_file(conn: sqlite3.Connection, serial: str, filename: str,
|
||||
ts: str) -> Optional[bool]:
|
||||
"""Move this file's row to `ts` when it sits under another time.
|
||||
ts: str, record_type: Optional[str] = None) -> Optional[bool]:
|
||||
"""Move this file's row to `ts` (and `record_type`) when it sits under
|
||||
another time or type.
|
||||
|
||||
The events table is unique on (serial, timestamp), so an event re-stored
|
||||
with a corrected time -- every Series-3 waveform after the event-time fix,
|
||||
@@ -768,6 +808,10 @@ class SeismoDb:
|
||||
stored as "imported.bw" -- so only a Blastware name is matched. Of
|
||||
several rows for one file, a reviewed one with a time moves first.
|
||||
|
||||
The type moves the same way: before v0.33.0 a row's type came from the
|
||||
filename, and with the type in the key (#51) a re-import under the file's
|
||||
own type would otherwise add a second row.
|
||||
|
||||
Returns True when the row was moved; None when there was nothing to move
|
||||
(no row for this file elsewhere, or this file's own row already holds
|
||||
`ts`), so the caller goes on as before; False when a different stored
|
||||
@@ -778,18 +822,20 @@ class SeismoDb:
|
||||
return None
|
||||
mine = conn.execute(
|
||||
"SELECT id, timestamp FROM events WHERE serial = ? AND blastware_filename = ? "
|
||||
"AND (timestamp IS NULL OR timestamp != ?) "
|
||||
"AND (timestamp IS NULL OR timestamp != ? OR record_type IS NOT ?) "
|
||||
"ORDER BY COALESCE(false_trigger, 0) DESC, timestamp IS NULL, rowid LIMIT 1",
|
||||
(serial, filename, ts),
|
||||
(serial, filename, ts, record_type),
|
||||
).fetchone()
|
||||
if mine is None:
|
||||
return None
|
||||
holder = conn.execute(
|
||||
"SELECT id, blastware_filename FROM events WHERE serial = ? AND timestamp = ?",
|
||||
(serial, ts),
|
||||
"SELECT id, blastware_filename FROM events WHERE serial = ? AND timestamp = ? "
|
||||
"AND record_type IS ?",
|
||||
(serial, ts, record_type),
|
||||
).fetchone()
|
||||
if holder is None:
|
||||
conn.execute("UPDATE events SET timestamp = ? WHERE id = ?", (ts, mine[0]))
|
||||
conn.execute("UPDATE events SET timestamp = ?, record_type = ? WHERE id = ?",
|
||||
(ts, record_type, mine[0]))
|
||||
log.info("insert_events: %s %s moved from %s to %s (corrected event time)",
|
||||
serial, filename, mine[1], ts)
|
||||
return True
|
||||
@@ -808,7 +854,8 @@ class SeismoDb:
|
||||
).fetchone()
|
||||
return dict(row) if row else None
|
||||
|
||||
def find_event_by_blastware_name(self, serial: str, filename: str) -> Optional[dict]:
|
||||
def find_event_by_blastware_name(self, serial: str, filename: str,
|
||||
record_type: Optional[str] = None) -> Optional[dict]:
|
||||
"""The row stored under `filename`'s Blastware name, or None.
|
||||
|
||||
A Blastware name encodes the serial and the event's second
|
||||
@@ -819,6 +866,10 @@ class SeismoDb:
|
||||
itself and the letterless form -- not the other letter, since in
|
||||
Histogram+Continuous a waveform can trigger in the second a histogram
|
||||
starts. Any other name ("imported.bw") matches nothing.
|
||||
|
||||
`record_type`: only a row of that type -- or an untyped one, which may be
|
||||
this event -- matches (#51: a same-second waveform / histogram twin shares
|
||||
the letterless name). Compared ignoring case.
|
||||
"""
|
||||
if blastware_filename_time(filename) is None:
|
||||
return None
|
||||
@@ -828,10 +879,14 @@ class SeismoDb:
|
||||
else:
|
||||
forms = (name, name + "W", name + "H")
|
||||
with self._connect() as conn:
|
||||
typed, args = "", (serial, *forms)
|
||||
if record_type is not None:
|
||||
typed = " AND (record_type IS NULL OR UPPER(record_type) = UPPER(?))"
|
||||
args = (*args, record_type)
|
||||
row = conn.execute(
|
||||
f"SELECT * FROM events WHERE serial = ? AND UPPER(blastware_filename) IN "
|
||||
f"({', '.join('?' * len(forms))}) ORDER BY rowid LIMIT 1",
|
||||
(serial, *forms),
|
||||
f"({', '.join('?' * len(forms))}){typed} ORDER BY rowid LIMIT 1",
|
||||
args,
|
||||
).fetchone()
|
||||
return dict(row) if row else None
|
||||
|
||||
|
||||
@@ -9,7 +9,7 @@ import threading
|
||||
import time
|
||||
from typing import Any, Callable, Dict, Optional
|
||||
|
||||
from .errors import ConnectFailed, DeviceError, NoAnswer, NotSupported, WrongUnit
|
||||
from .errors import BadRequest, ConnectFailed, DeviceError, NoAnswer, NotSupported, WrongUnit
|
||||
from .events import parse_event_id
|
||||
from .locks import UnitLocks
|
||||
from .models import (CallHomeState, ChangeResult, DownloadedEvent, EventList, UnitAddress, UnitInfo,
|
||||
@@ -17,6 +17,7 @@ from .models import (CallHomeState, ChangeResult, DownloadedEvent, EventList, Un
|
||||
from .s3 import Series3Adapter, default_s3_client_factory
|
||||
from .s4 import (
|
||||
Series4Session, default_s4_client_factory, s4_call_home_state, s4_change_call_home, s4_change_monitoring,
|
||||
s4_change_settings,
|
||||
s4_download_event, s4_identify, s4_list_events, s4_settings, s4_status,
|
||||
)
|
||||
from .series import normalise_serial, series_for_serial
|
||||
@@ -27,6 +28,9 @@ log = logging.getLogger("sfm.device_access")
|
||||
# reads, a second apart -- not the start/stop window.
|
||||
_CALL_HOME_VERIFY_TIMEOUT_S = 3.0
|
||||
_CALL_HOME_VERIFY_INTERVAL_S = 1.0
|
||||
# A settings read-back is one block read (seconds over cellular): two tries, a second apart.
|
||||
_SETTINGS_VERIFY_TIMEOUT_S = 2.0
|
||||
_SETTINGS_VERIFY_INTERVAL_S = 1.0
|
||||
|
||||
|
||||
class DeviceAccess:
|
||||
@@ -140,6 +144,34 @@ class DeviceAccess:
|
||||
lambda c, s: s4_change_call_home(c, s, address=address, **kw),
|
||||
change=True)
|
||||
|
||||
def change_settings(self, address: UnitAddress, serial: str, *, changes: dict,
|
||||
revision: Optional[str], dry_run: bool = False,
|
||||
caller: str = "api") -> ChangeResult:
|
||||
"""Change the unit's settings (spec row 10, phase 5). A dry run is the
|
||||
preview: old -> new per field and a `revision`. A live change needs that
|
||||
revision; it is audited, identity-checked, sent once, never retried, and
|
||||
read back. Refused before any I/O: no changes, a live call without a
|
||||
revision, no audit log."""
|
||||
serial = normalise_serial(serial)
|
||||
series_for_serial(serial) # BadRequest (422) before anything else
|
||||
if not isinstance(changes, dict) or not changes:
|
||||
raise BadRequest("no settings to change -- nothing sent")
|
||||
if not dry_run and not revision:
|
||||
raise BadRequest("preview first: a live change needs the revision from its preview "
|
||||
"-- nothing sent")
|
||||
if not dry_run and self._audit is None:
|
||||
raise NotSupported("no audit log is configured -- SFM refuses to change a unit "
|
||||
"without one (nothing sent)")
|
||||
kw = dict(changes=changes, revision=revision, dry_run=dry_run, audit=self._audit,
|
||||
caller=caller, sleep=self._sleep,
|
||||
verify_timeout_s=_SETTINGS_VERIFY_TIMEOUT_S,
|
||||
verify_interval_s=_SETTINGS_VERIFY_INTERVAL_S)
|
||||
return self._dispatch(
|
||||
address, serial,
|
||||
lambda a, s: self._s3.change_settings(a, s, **kw),
|
||||
lambda c, s: s4_change_settings(c, s, address=address, **kw),
|
||||
change=True)
|
||||
|
||||
def held_serial(self, address: UnitAddress) -> Optional[str]:
|
||||
"""Serial of the OPEN held Series-4 line at this address, else None. No I/O."""
|
||||
with self._sessions_guard:
|
||||
|
||||
@@ -63,6 +63,12 @@ def call_home_change(enabled: bool) -> ChangeKind:
|
||||
else ChangeKind("disable call-home", "disabled", "disabled"))
|
||||
|
||||
|
||||
def settings_change() -> ChangeKind:
|
||||
"""A settings change (phase 5): its "state" is a read-back verdict --
|
||||
"as asked" (the unit holds what was written), "unchanged", or "differs"."""
|
||||
return ChangeKind("change settings", "as asked", "applied")
|
||||
|
||||
|
||||
def _take_snapshot(snapshot: Optional[Callable[[], Dict[str, Any]]]) -> Optional[Dict[str, Any]]:
|
||||
"""The caller's record of what the unit holds after the change -- for the
|
||||
result and the audit row only. It never decides the outcome."""
|
||||
|
||||
@@ -88,6 +88,18 @@ class EventNotFound(DeviceError):
|
||||
http_status = 404
|
||||
|
||||
|
||||
class SettingsChanged(DeviceError):
|
||||
"""The unit's settings changed since the preview the request names (a keypad
|
||||
edit, another program, or a preview of another unit). Nothing was sent."""
|
||||
http_status = 409
|
||||
|
||||
|
||||
class ChangeRefused(DeviceError):
|
||||
"""A change SFM will not send to this unit, and why -- its factory setup, a
|
||||
schedule that would undo it, a block SFM has not seen. Nothing was sent."""
|
||||
http_status = 409
|
||||
|
||||
|
||||
class StaleEvent(DeviceError):
|
||||
"""The event at that key is not the one listed -- the unit was erased, or
|
||||
its memory wrapped, since the list was read."""
|
||||
|
||||
+141
-22
@@ -11,15 +11,23 @@ from minimateplus import MiniMateClient
|
||||
from minimateplus.blastware_file import blastware_file_bytes, blastware_filename, with_type_letter
|
||||
from minimateplus.event_file_io import _GEO_INT16_FS
|
||||
from minimateplus.framing import build_bw_write_frame, unescape_reply
|
||||
from micromate.setup_block import decode_setup
|
||||
from micromate.setup_fields import (
|
||||
SettingsValueError, changes_bytes, check_changes, editable_fields, encode_setup, field_rows,
|
||||
field_values, settings_state,
|
||||
)
|
||||
from micromate.setup_fields import revision as settings_revision
|
||||
from minimateplus.protocol import (
|
||||
SUB_CALL_HOME_CONFIRM, SUB_CALL_HOME_WRITE, SUB_START_MONITORING, SUB_STOP_MONITORING,
|
||||
ImageRefused, call_home_enabled, call_home_image, is_call_home_block, write_image,
|
||||
SUB_CALL_HOME_CONFIRM, SUB_CALL_HOME_WRITE, SUB_COMPLIANCE_WRITE, SUB_EVENT_INDEX_WRITE,
|
||||
SUB_START_MONITORING, SUB_STOP_MONITORING, SUB_TRIGGER_CONFIG_WRITE, SUB_WAVEFORM_DATA_WRITE,
|
||||
ImageRefused, call_home_enabled, call_home_image, is_call_home_block, is_compliance_content,
|
||||
write_image,
|
||||
)
|
||||
from minimateplus.transport import TcpTransport
|
||||
|
||||
from .errors import (DeviceError, EventNotFound, MalformedReply, NoAnswer, NotSupported, StaleEvent,
|
||||
UnitStateUnknown, WrongUnit, translate)
|
||||
from .change import call_home_change, monitoring_change, run_change
|
||||
from .errors import (BadRequest, ChangeRefused, DeviceError, EventNotFound, MalformedReply, NoAnswer, NotSupported,
|
||||
SettingsChanged, StaleEvent, UnitStateUnknown, WrongUnit, translate)
|
||||
from .change import call_home_change, monitoring_change, run_change, settings_change
|
||||
from .events import iso_of, make_event_id, stamp_of
|
||||
from .models import (CallHomeState, ChangeResult, DownloadedEvent, EventList, EventRef, UnitAddress,
|
||||
UnitInfo, UnitSettings, UnitStatus)
|
||||
@@ -49,6 +57,25 @@ S3_CALL_HOME_WHILE_MONITORING = ("did not return its call-home settings -- a Min
|
||||
# The 0x1C flag byte (section[1]): the only values ever measured. 0x10 is
|
||||
# BE11529 monitoring (2026-04-08); 0x0B is BE9441 recording a histogram,
|
||||
# confirmed at the unit (2026-10-26). Anything else is refused for a change.
|
||||
# Measured 2026-11-03 (BE9441's 10-26 recording, 5 / 5 reads): while monitoring, a
|
||||
# MiniMate answers the 1A settings read with its device-info block.
|
||||
S3_SETTINGS_WHILE_MONITORING = ("did not return its settings -- a MiniMate answers this way "
|
||||
"while monitoring; stop monitoring first (a stop makes it call in "
|
||||
"if call-home is on)")
|
||||
# Blastware's settings write, in its order (push_config_raw): event index, the
|
||||
# settings block in addressed chunks, trigger, waveform data, with their confirms.
|
||||
_S3_SETTINGS_STEPS = ((0x68, "event index (as read)"), (0x73, "confirm B"),
|
||||
(0x71, "settings block"), (0x72, "confirm A"),
|
||||
(0x82, "trigger block (as read)"), (0x83, "trigger confirm"),
|
||||
(0x69, "waveform data (as read)"), (0x74, "confirm C"), (0x72, "confirm A"))
|
||||
_S3_TAIL_WARNING = ("the two bytes after the settings block go out as 00 00 (Blastware sends "
|
||||
"its own constant; the unit took it at the bench 2026-11-04)")
|
||||
# Measured at the bench 2026-11-04 (BE9441): a write sent while the setup menu was open
|
||||
# was acknowledged and read back, then lost when the operator pressed Cancel or Save --
|
||||
# the menu writes its own copy of the whole block back.
|
||||
_S3_MENU_WARNING = ("if someone is in this unit's setup menu, this change is lost when they "
|
||||
"leave it (Cancel or Save writes the menu's copy back)")
|
||||
|
||||
S3_RUN_STATES = {0x00: "idle", 0x10: "monitoring", 0x0B: "monitoring"}
|
||||
|
||||
|
||||
@@ -435,29 +462,121 @@ class Series3Adapter:
|
||||
is_refusal=lambda e: isinstance(e, ImageRefused))
|
||||
return self._run(address, op, retry=False)
|
||||
|
||||
def change_settings(self, address: UnitAddress, serial: str, *, changes: dict,
|
||||
revision: Optional[str], dry_run: bool, audit: Any, caller: str,
|
||||
sleep: Callable[[float], None], verify_timeout_s: float,
|
||||
verify_interval_s: float) -> ChangeResult:
|
||||
"""Series-3 pieces for the shared core (phase 5): read the four settings
|
||||
blocks, patch the settings block's fields (micromate.setup_fields), send
|
||||
Blastware's sequence through push_config_raw with the other three blocks
|
||||
as read, re-read the settings. One attempt, never retried.
|
||||
|
||||
Refused before anything is sent: a monitoring unit (it answers 1A with its
|
||||
device-info block); a value the unit does not allow (BadRequest); a live
|
||||
call whose `revision` is not this read's (SettingsChanged)."""
|
||||
def op(client: Any) -> ChangeResult:
|
||||
st: dict = {}
|
||||
reads: list = []
|
||||
|
||||
def read_serial() -> str:
|
||||
return client.connect().serial or "" # a fresh connection: the 0x15 read
|
||||
|
||||
def read_state() -> str:
|
||||
client.wake(attempt_s=S3_WAKE_ATTEMPT_S, deadline_s=S3_WAKE_DEADLINE_S)
|
||||
if st:
|
||||
now = client.read_compliance_content()
|
||||
if not is_compliance_content(now):
|
||||
raise MalformedReply("the read-back did not return the settings block")
|
||||
reads.append(now)
|
||||
return settings_state(st["setup"], st["image"], now, series=3)
|
||||
blocks = client.read_settings_blocks()
|
||||
setup = blocks["compliance"]
|
||||
if not is_compliance_content(setup):
|
||||
raise UnitStateUnknown(f"{serial} {S3_SETTINGS_WHILE_MONITORING} -- nothing sent")
|
||||
try:
|
||||
normal = check_changes(setup, 3, changes)
|
||||
except SettingsValueError as exc:
|
||||
raise BadRequest(f"{exc} -- nothing sent") from exc
|
||||
# What the preview showed: the settings block and the changes. The other
|
||||
# three blocks are re-read here and sent back as read (the trigger block's
|
||||
# byte 5 "differs by unit and session", #46).
|
||||
rev = settings_revision([setup, changes_bytes(normal)])
|
||||
if not dry_run and revision != rev:
|
||||
raise SettingsChanged(f"{serial}'s settings, or the changes asked for, are not "
|
||||
"the ones previewed -- preview again; nothing sent")
|
||||
image = encode_setup(setup, 3, normal)
|
||||
blocked = []
|
||||
for sub, block in ((SUB_EVENT_INDEX_WRITE, blocks["event_index"]),
|
||||
(SUB_COMPLIANCE_WRITE, image),
|
||||
(SUB_TRIGGER_CONFIG_WRITE, blocks["trigger"]),
|
||||
(SUB_WAVEFORM_DATA_WRITE, blocks["waveform"])):
|
||||
try:
|
||||
write_image(sub, block, escaped=False) # push_config_raw's own check
|
||||
except ValueError as exc:
|
||||
blocked.append(f"this unit's {exc} -- SFM has not seen a block like it")
|
||||
st.update(blocks=blocks, setup=setup, image=image, changes=normal, revision=rev,
|
||||
blocked=blocked)
|
||||
reads.append(setup)
|
||||
return settings_state(setup, image, setup, series=3)
|
||||
|
||||
def describe_plan() -> dict:
|
||||
b = st["blocks"]
|
||||
lens = {0x68: len(b["event_index"]), 0x71: len(st["image"]) + 2,
|
||||
0x82: len(b["trigger"]), 0x69: len(b["waveform"])}
|
||||
if st["blocked"] and not dry_run:
|
||||
raise ChangeRefused("; ".join(st["blocked"]) + " -- nothing sent")
|
||||
steps = [] if st["blocked"] else [
|
||||
{"sub": f"0x{sub:02X}", "what": what, "data_len": lens.get(sub, 0)}
|
||||
for sub, what in _S3_SETTINGS_STEPS]
|
||||
return {"action": "settings write", "blocked": list(st["blocked"]), "steps": steps,
|
||||
"fields": field_rows(st["setup"], st["image"], 3, st["changes"]),
|
||||
"revision": st["revision"], "warnings": [_S3_MENU_WARNING, _S3_TAIL_WARNING]}
|
||||
|
||||
def send() -> dict:
|
||||
b = st["blocks"]
|
||||
client.push_config_raw(b["event_index"], st["image"], b["trigger"], b["waveform"],
|
||||
escaped=False) # every block read is logical
|
||||
return {"subs": [f"0x{0xFF - sub:02X}" for sub, _ in _S3_SETTINGS_STEPS]}
|
||||
|
||||
def snapshot() -> dict:
|
||||
before, after = st["setup"], reads[-1]
|
||||
return {"fields": field_rows(before, st["image"], 3, st["changes"], now=after),
|
||||
"before": before.hex(), "after": after.hex(),
|
||||
"changed_offsets": [i for i in range(min(len(before), len(after)))
|
||||
if before[i] != after[i]]}
|
||||
|
||||
return run_change(
|
||||
kind=settings_change(), serial=serial, series=3, dry_run=dry_run,
|
||||
even_if_already=False, audit=audit, address=address, caller=caller, sleep=sleep,
|
||||
verify_timeout_s=verify_timeout_s, verify_interval_s=verify_interval_s,
|
||||
read_serial=read_serial, read_state=read_state, describe_plan=describe_plan,
|
||||
send=send, snapshot=snapshot,
|
||||
# raised before the first frame goes out: audited as nothing sent
|
||||
is_refusal=lambda e: isinstance(e, ImageRefused))
|
||||
return self._run(address, op, retry=False)
|
||||
|
||||
def settings(self, address: UnitAddress, serial: str) -> UnitSettings:
|
||||
"""The 1A read assembled into the logical block and decoded by the shared
|
||||
settings codec (phase 5)."""
|
||||
def op(client: Any) -> UnitSettings:
|
||||
info = client.connect()
|
||||
self._check(info.serial, serial, address)
|
||||
cc = info.compliance_config
|
||||
if cc is None:
|
||||
raise MalformedReply("could not read the unit's settings (SUB 0x1A)")
|
||||
mode = None
|
||||
if cc.recording_mode is not None:
|
||||
mode = S3_MODES.get(cc.recording_mode, f"unknown (0x{cc.recording_mode:02x})")
|
||||
notes = {
|
||||
label: value for label, value in (
|
||||
("Project", cc.project), ("Client", cc.client), ("User Name", cc.operator),
|
||||
("Seis Loc", cc.sensor_location), ("Extended Notes", cc.notes),
|
||||
) if value is not None
|
||||
}
|
||||
content = client.read_compliance_content()
|
||||
if not is_compliance_content(content):
|
||||
raise UnitStateUnknown(f"{serial} {S3_SETTINGS_WHILE_MONITORING}")
|
||||
v = field_values(content, 3)
|
||||
name = decode_setup(content + bytes(2), verify=False).name # Series 3 reads no CRC
|
||||
labels = {d["field"]: d["label"] for d in editable_fields(content, 3)}
|
||||
notes = {labels[f]: v[f] for f in ("note_1", "note_2", "note_3", "note_4")}
|
||||
code = content[5]
|
||||
return UnitSettings(
|
||||
serial=info.serial, series=3, setup_name=cc.setup_name, record_mode=mode,
|
||||
sample_rate=cc.sample_rate, record_time_s=cc.record_time,
|
||||
histogram_interval_s=cc.histogram_interval_sec, geo_trigger_ips=cc.trigger_level_geo,
|
||||
serial=info.serial, series=3, setup_name=name or None,
|
||||
record_mode=S3_MODES.get(code, f"unknown (0x{code:02x})"),
|
||||
sample_rate=v["sample_rate"], record_time_s=v["record_time_s"],
|
||||
histogram_interval_s=v["histogram_interval_s"], geo_trigger_ips=v["geo_trigger_ips"],
|
||||
notes=notes,
|
||||
detail={"record_mode_code": cc.recording_mode, "alarm_level_geo": cc.alarm_level_geo,
|
||||
"geo_range": cc.geo_range},
|
||||
detail={"record_mode_code": code, "alarm_level_geo": v["geo_alarm_ips"],
|
||||
"geo_range": v["geo_range"], "editable": editable_fields(content, 3)},
|
||||
)
|
||||
return self._run(address, op)
|
||||
|
||||
|
||||
+136
-5
@@ -19,16 +19,28 @@ from typing import Any, Callable, Optional, TypeVar
|
||||
from micromate.client import MicromateClient
|
||||
from micromate.opcodes import OpcodeRefused
|
||||
from micromate.protocol import THOR_CHUNK_SIZE
|
||||
from micromate.protocol import ProtocolError as _MMProtocolError
|
||||
from micromate.schedule import parse_schedule, schedule_conflicts
|
||||
from micromate.setup_block import decode_setup
|
||||
from micromate.setup_fields import (
|
||||
SettingsValueError, changes_bytes, check_changes, editable_fields, encode_setup, field_rows,
|
||||
settings_state,
|
||||
)
|
||||
from micromate.setup_fields import revision as settings_revision
|
||||
from micromate.writes import (
|
||||
is_call_home_content, plan_call_home_enabled, plan_start_monitoring, plan_stop_monitoring,
|
||||
is_call_home_content, plan_call_home_enabled, plan_setup_push, plan_start_monitoring,
|
||||
plan_stop_monitoring,
|
||||
)
|
||||
from minimateplus.transport import BaseTransport, SerialTransport, TcpTransport
|
||||
|
||||
from .errors import (
|
||||
AuditIncomplete, CallHomeInProgress, ChangeUnconfirmed, DeviceError, EventNotFound,
|
||||
MalformedReply, StaleEvent, UnitStateUnknown, WrongUnit, translate,
|
||||
AuditIncomplete, BadRequest, CallHomeInProgress, ChangeRefused, ChangeUnconfirmed, DeviceError,
|
||||
EventNotFound, MalformedReply, SettingsChanged, StaleEvent, UnitStateUnknown, WrongUnit,
|
||||
translate,
|
||||
)
|
||||
from .change import (
|
||||
CALL_HOME_MESSAGE, call_home_change, monitoring_change, run_change, settings_change,
|
||||
)
|
||||
from .change import CALL_HOME_MESSAGE, call_home_change, monitoring_change, run_change
|
||||
from .events import iso_of, make_event_id, stamp_of
|
||||
from .models import (CallHomeState, ChangeResult, DownloadedEvent, EventList, EventRef, UnitAddress,
|
||||
UnitInfo, UnitSettings, UnitStatus)
|
||||
@@ -268,7 +280,8 @@ def s4_status(client: Any, serial: str, run_state: bool = False) -> UnitStatus:
|
||||
|
||||
|
||||
def s4_settings(client: Any, serial: str) -> UnitSettings:
|
||||
s = client.get_setup()
|
||||
content = client.get_setup_content()
|
||||
s = decode_setup(content)
|
||||
return UnitSettings(
|
||||
serial=serial, series=4, setup_name=s.name, record_mode=s.record_mode_name,
|
||||
sample_rate=s.sample_rate, record_time_s=s.record_time_s,
|
||||
@@ -293,6 +306,7 @@ def s4_settings(client: Any, serial: str) -> UnitSettings:
|
||||
"distance_ft": s.distance_ft,
|
||||
"charge_weight_lb": s.charge_weight_lb,
|
||||
"scaled_distance": s.scaled_distance,
|
||||
"editable": editable_fields(content, 4),
|
||||
},
|
||||
)
|
||||
|
||||
@@ -452,3 +466,120 @@ def s4_change_call_home(client: Any, serial: str, *, enabled: bool, dry_run: boo
|
||||
is_ring=lambda e: isinstance(e, RingDetected),
|
||||
pre_send=lambda: client.read_unsolicited(),
|
||||
snapshot=snapshot)
|
||||
|
||||
|
||||
# ── Changing settings (phase 5) ──────────────────────────────────────────────
|
||||
|
||||
S4_SETTINGS_WHILE_MONITORING = ("is monitoring -- stop it first (a stop makes it call in if "
|
||||
"call-home is on)")
|
||||
_EDIT_BUFFER_WARNING = ("this reads the unit's keypad edit buffer: if someone is in its menu, "
|
||||
"their unsaved edits are sent too")
|
||||
_FACTORY = "factory.mmb"
|
||||
|
||||
|
||||
def s4_change_settings(client: Any, serial: str, *, changes: dict, revision: Optional[str],
|
||||
dry_run: bool, audit: Any, address: UnitAddress, caller: str,
|
||||
sleep: Callable[[float], None], verify_timeout_s: float,
|
||||
verify_interval_s: float) -> ChangeResult:
|
||||
"""Series-4 pieces for the shared core: read the name, preferences, trigger
|
||||
and setup blocks and the schedule; patch the setup's fields
|
||||
(micromate.setup_fields); send THOR's setup push under the active setup's own
|
||||
name; read the setup back. The plan is built from the read run_change made
|
||||
just before it, and that same plan is the one sent.
|
||||
|
||||
Refused before anything is sent: a monitoring unit; values the unit does not
|
||||
allow (BadRequest); a live call whose `revision` is not this read's
|
||||
(SettingsChanged); the factory setup, a schedule that would load another
|
||||
setup, an unreadable schedule, or a block SFM has not seen (ChangeRefused,
|
||||
shown as `blocked` in a preview)."""
|
||||
st: dict = {}
|
||||
reads: list = []
|
||||
|
||||
def first_read() -> str:
|
||||
name = client.get_active_setup_raw()
|
||||
prefs = client.get_prefs_content()
|
||||
trigger = client.get_trigger_content()
|
||||
setup = client.get_setup_content()
|
||||
try:
|
||||
normal = check_changes(setup, 4, changes)
|
||||
except SettingsValueError as exc:
|
||||
raise BadRequest(f"{exc} -- nothing sent") from exc
|
||||
# What the preview showed: the target name, the setup block, the changes. The
|
||||
# preferences and trigger blocks are re-read here and sent back as read.
|
||||
rev = settings_revision([name.encode("ascii", "replace"), setup, changes_bytes(normal)])
|
||||
if not dry_run and revision != rev:
|
||||
raise SettingsChanged(f"{serial}'s settings, or the changes asked for, are not the ones "
|
||||
"previewed -- preview again; nothing sent")
|
||||
image = encode_setup(setup, 4, normal)
|
||||
blocked: list = []
|
||||
warnings = [_EDIT_BUFFER_WARNING]
|
||||
if name.strip().casefold() == _FACTORY:
|
||||
blocked.append("this unit is running its factory setup; load any other setup on "
|
||||
"its keypad, then try again")
|
||||
try:
|
||||
entries = parse_schedule(client.read_schedule())
|
||||
except (_MMProtocolError, ValueError) as exc:
|
||||
blocked.append(f"could not read this unit's schedule ({exc}) -- SFM will not change "
|
||||
"a unit whose schedule it cannot check")
|
||||
else:
|
||||
conflicts = schedule_conflicts(entries, name)
|
||||
for e in conflicts:
|
||||
blocked.append(f"this unit's schedule loads {e.setup} at {e.time}, which would "
|
||||
"replace this change")
|
||||
for e in entries:
|
||||
if "start_with_setup" in e.actions and e not in conflicts:
|
||||
warnings.append(f"the unit's schedule loads this setup at {e.time}; the "
|
||||
"change survives it")
|
||||
plan = None
|
||||
try:
|
||||
plan = plan_setup_push(prefs, trigger, image, name)
|
||||
except ValueError as exc:
|
||||
blocked.append(f"this unit's {exc} -- SFM has not seen a block like it")
|
||||
st.update(name=name, prefs=prefs, trigger=trigger, setup=setup, image=image,
|
||||
changes=normal, revision=rev, blocked=blocked, warnings=warnings, plan=plan)
|
||||
reads.append(setup)
|
||||
return settings_state(setup, image, setup, series=4)
|
||||
|
||||
def read_state() -> str:
|
||||
run = client.read_run_state().name
|
||||
if run == "calling_home" or run.startswith("unknown"):
|
||||
return run # the core refuses both; a write waits for a known state
|
||||
if not st:
|
||||
if run == "monitoring":
|
||||
raise UnitStateUnknown(f"{serial} {S4_SETTINGS_WHILE_MONITORING} -- nothing sent")
|
||||
return first_read()
|
||||
now = client.get_setup_content()
|
||||
reads.append(now)
|
||||
return settings_state(st["setup"], st["image"], now, series=4)
|
||||
|
||||
def describe_plan() -> dict:
|
||||
ok = st["plan"] is not None and not st["blocked"]
|
||||
d = st["plan"].describe() if ok else {"action": "setup push", "steps": [], "warnings": []}
|
||||
d["warnings"] = list(st["warnings"]) + list(d.get("warnings", []))
|
||||
d.update(fields=field_rows(st["setup"], st["image"], 4, st["changes"]),
|
||||
revision=st["revision"], blocked=list(st["blocked"]))
|
||||
if st["blocked"] and not dry_run:
|
||||
raise ChangeRefused("; ".join(st["blocked"]) + " -- nothing sent")
|
||||
return d
|
||||
|
||||
def send() -> dict:
|
||||
acks = client.protocol.execute(st["plan"])
|
||||
return {"subs": [f"0x{a.sub:02X}" for a in acks], "data": [bytes(a.data).hex() for a in acks]}
|
||||
|
||||
def snapshot() -> dict:
|
||||
before, after = st["setup"], reads[-1]
|
||||
return {"fields": field_rows(before, st["image"], 4, st["changes"], now=after),
|
||||
"before": before.hex(), "after": after.hex(),
|
||||
"changed_offsets": _changed_offsets(before, after),
|
||||
"prefs": st["prefs"].hex(), "trigger": st["trigger"].hex()}
|
||||
|
||||
return run_change(
|
||||
kind=settings_change(), serial=serial, series=4, dry_run=dry_run, even_if_already=False,
|
||||
audit=audit, address=address, caller=caller, sleep=sleep,
|
||||
verify_timeout_s=verify_timeout_s, verify_interval_s=verify_interval_s,
|
||||
read_serial=lambda: client.serial(refresh=True),
|
||||
read_state=read_state, describe_plan=describe_plan, send=send,
|
||||
is_refusal=lambda e: isinstance(e, OpcodeRefused),
|
||||
is_ring=lambda e: isinstance(e, RingDetected),
|
||||
pre_send=lambda: client.read_unsolicited(),
|
||||
snapshot=snapshot)
|
||||
@@ -34,6 +34,14 @@ Layout written to `<filename>.h5`:
|
||||
sensor_location str
|
||||
job_number int (only when read; kept while not shown)
|
||||
job_number_enabled bool (Blastware prints the job number)
|
||||
battery_volts, triggered_by, trigger_sources, trigger_level_geo_ips,
|
||||
trigger_level_mic_psi, firmware_version, dsp_version, model,
|
||||
calibration_date (ISO), calibrated_by
|
||||
(each only when read from the event file)
|
||||
histogram_interval_sec int (histograms)
|
||||
/intervals (histograms, when read)
|
||||
half_period/<ch> uint16 samples per interval; Hz = (sample rate / 2) / it
|
||||
pvs_ips float32 each interval's vector sum, in/s
|
||||
peak_tran_ips float (from 0C; authoritative)
|
||||
peak_vert_ips float
|
||||
peak_long_ips float
|
||||
@@ -262,6 +270,24 @@ def write_event_hdf5(
|
||||
if pi is not None and getattr(pi, "job_number", None) is not None:
|
||||
attrs["job_number"] = int(pi.job_number)
|
||||
attrs["job_number_enabled"] = bool(pi.job_number_enabled)
|
||||
# Read from a Blastware file's identity and setup blocks; absent when not read.
|
||||
for attr, value in (
|
||||
("battery_volts", getattr(event, "battery_volts", None)),
|
||||
("triggered_by", getattr(event, "triggered_by", None)),
|
||||
("trigger_sources", getattr(event, "trigger_sources", None)),
|
||||
("trigger_level_geo_ips", getattr(event, "trigger_level_geo", None)),
|
||||
("trigger_level_mic_psi", getattr(event, "trigger_level_mic_psi", None)),
|
||||
("histogram_interval_sec", getattr(event, "histogram_interval_sec", None)),
|
||||
):
|
||||
if value is not None:
|
||||
attrs[attr] = value
|
||||
di = getattr(event, "device_info", None)
|
||||
if di is not None:
|
||||
for attr in ("firmware_version", "dsp_version", "model", "calibrated_by"):
|
||||
if getattr(di, attr, None):
|
||||
attrs[attr] = getattr(di, attr)
|
||||
if getattr(di, "calibration_date", None) is not None:
|
||||
attrs["calibration_date"] = di.calibration_date.isoformat()
|
||||
attrs["peak_tran_ips"] = float(pv.tran if pv and pv.tran is not None else 0.0)
|
||||
attrs["peak_vert_ips"] = float(pv.vert if pv and pv.vert is not None else 0.0)
|
||||
attrs["peak_long_ips"] = float(pv.long if pv and pv.long is not None else 0.0)
|
||||
@@ -283,6 +309,22 @@ def write_event_hdf5(
|
||||
compression="gzip", compression_opts=4, shuffle=True,
|
||||
)
|
||||
|
||||
# /intervals — a histogram's per-interval detail as the file holds it:
|
||||
# each channel's half-period in samples (frequency = (sample rate / 2)
|
||||
# / half-period; 0 is Blastware's "N/A") and each interval's vector sum.
|
||||
half_periods = getattr(event, "interval_half_periods", None)
|
||||
interval_pvs = getattr(event, "interval_pvs", None)
|
||||
if half_periods or interval_pvs:
|
||||
igrp_iv = f.create_group("intervals")
|
||||
if half_periods:
|
||||
hgrp = igrp_iv.create_group("half_period")
|
||||
for ch, hps in half_periods.items():
|
||||
hgrp.create_dataset(ch, data=np.asarray(hps, dtype="uint16"),
|
||||
compression="gzip", compression_opts=4, shuffle=True)
|
||||
if interval_pvs:
|
||||
igrp_iv.create_dataset("pvs_ips", data=np.asarray(interval_pvs, dtype="float32"),
|
||||
compression="gzip", compression_opts=4, shuffle=True)
|
||||
|
||||
# /samples_int16 — optional raw ADC counts (preserved for analysis
|
||||
# tools that want pre-conversion data). Cheap to include.
|
||||
if include_int16:
|
||||
|
||||
+33
-6
@@ -134,16 +134,43 @@ def _overlay_s4_record(ev: Any, record: dict) -> None:
|
||||
ev.project_info.sensor_location = location
|
||||
|
||||
|
||||
def _download_record_type(dl: DownloadedEvent) -> Optional[str]:
|
||||
"""The download's own record type -- "Waveform" / "Histogram", as every stored
|
||||
row has it -- from its file: a Series-3 file's STRT[18], a Series-4 name's
|
||||
IDFW / IDFH. None when it does not read (then any row at its second counts)."""
|
||||
if dl.series == 4:
|
||||
ext = dl.filename.rsplit(".", 1)[-1].upper()
|
||||
return {"IDFW": "Waveform", "IDFH": "Histogram"}.get(ext)
|
||||
if not dl.bw_bytes:
|
||||
return None
|
||||
try:
|
||||
from minimateplus.event_file_io import decode_blastware_bytes
|
||||
return decode_blastware_bytes(dl.bw_bytes).record_type
|
||||
except Exception: # noqa: BLE001 -- a check, not a decode
|
||||
return None
|
||||
|
||||
|
||||
def _same_type(row_type: Optional[str], mine: Optional[str]) -> bool:
|
||||
"""An untyped row, or a download whose type does not read, matches
|
||||
conservatively: it may be this event."""
|
||||
return row_type is None or mine is None or row_type.casefold() == mine.casefold()
|
||||
|
||||
|
||||
def persist_download(dl: DownloadedEvent, *, store: Any, db: Any) -> EventDownload:
|
||||
# Never merge: a row for (serial, timestamp) means the event is stored, and
|
||||
# whoever stored it first keeps it. No store call, no insert, no sidecar.
|
||||
# Never merge: a row for (serial, timestamp, record type) means the event is
|
||||
# stored, and whoever stored it first keeps it. No store call, no insert, no
|
||||
# sidecar. The type matters since #51: a waveform and a histogram recorded in
|
||||
# the same second (Histogram + Continuous) are two events.
|
||||
kind = _download_record_type(dl)
|
||||
if dl.timestamp is not None:
|
||||
rows = db.query_events(serial=dl.serial, from_dt=dl.timestamp, to_dt=dl.timestamp, limit=1)
|
||||
rows = db.query_events(serial=dl.serial, from_dt=dl.timestamp, to_dt=dl.timestamp, limit=10)
|
||||
rows = [r for r in rows if _same_type(r.get("record_type"), kind)]
|
||||
if rows:
|
||||
return _already_stored(dl, rows[0])
|
||||
# A histogram's row is stored at its file's time, a second before the unit's
|
||||
# on most (#51), so the time above misses it; its Blastware name does not.
|
||||
row = db.find_event_by_blastware_name(dl.serial, dl.filename)
|
||||
# The Blastware name encodes the event's second (a second guard; before #51 a
|
||||
# histogram's row sat a second off the unit's time). Both twins share the
|
||||
# letterless name, so it too is held to the type.
|
||||
row = db.find_event_by_blastware_name(dl.serial, dl.filename, record_type=kind)
|
||||
if row is not None:
|
||||
return _already_stored(dl, row)
|
||||
if dl.series == 4:
|
||||
|
||||
+50
-133
@@ -50,7 +50,7 @@ import tempfile
|
||||
import threading
|
||||
import time
|
||||
from pathlib import Path
|
||||
from typing import Mapping, Optional
|
||||
from typing import Any, Dict, Mapping, Optional
|
||||
|
||||
# FastAPI / Pydantic
|
||||
try:
|
||||
@@ -426,6 +426,7 @@ _SERIAL_AWARE_PATHS = frozenset({
|
||||
"/device/events", "/device/events/download",
|
||||
"/device/monitor/start", "/device/monitor/stop",
|
||||
"/device/call_home/state", "/device/call_home/enable", "/device/call_home/disable",
|
||||
"/device/settings/change",
|
||||
})
|
||||
|
||||
|
||||
@@ -1112,145 +1113,61 @@ def device_event_blastware_file(
|
||||
|
||||
# ── Write endpoints ───────────────────────────────────────────────────────────
|
||||
|
||||
class DeviceConfigBody(BaseModel):
|
||||
"""
|
||||
Request body for POST /device/config.
|
||||
|
||||
All fields are optional — only supplied (non-null) fields are written to
|
||||
the device. All other config bytes are round-tripped verbatim.
|
||||
|
||||
Recording parameters
|
||||
--------------------
|
||||
recording_mode : Recording mode enum. Values: 0=Single Shot, 1=Continuous, 3=Histogram, 4=Histogram+Continuous.
|
||||
sample_rate : Samples per second. Valid values: 1024, 2048, 4096.
|
||||
record_time : Record duration in seconds (e.g. 1.0, 2.0, 3.0).
|
||||
|
||||
Trigger / alarm thresholds and range (geo channels)
|
||||
----------------------------------------------------
|
||||
trigger_level_geo : Trigger threshold in in/s (e.g. 0.5).
|
||||
alarm_level_geo : Alarm threshold in in/s (e.g. 1.0).
|
||||
geo_range : Geophone range/sensitivity. 0=Normal 10.000 in/s, 1=Sensitive 1.250 in/s.
|
||||
Project / operator strings (max 41 ASCII characters each)
|
||||
----------------------------
|
||||
project : Project description.
|
||||
client_name : Client / company name.
|
||||
operator : Operator / technician name.
|
||||
seis_loc : Sensor location description.
|
||||
notes : Extended notes.
|
||||
"""
|
||||
# Recording parameters
|
||||
recording_mode: Optional[int] = None
|
||||
sample_rate: Optional[int] = None
|
||||
record_time: Optional[float] = None
|
||||
histogram_interval_sec: Optional[int] = None # seconds: 2, 5, 15, 60, 300, 900 (mode-gated)
|
||||
# Threshold parameters / geo range
|
||||
trigger_level_geo: Optional[float] = None
|
||||
alarm_level_geo: Optional[float] = None
|
||||
geo_range: Optional[int] = None # 0=Normal 10.000 in/s, 1=Sensitive 1.250 in/s
|
||||
# Project / operator strings
|
||||
project: Optional[str] = None
|
||||
client_name: Optional[str] = None
|
||||
operator: Optional[str] = None
|
||||
seis_loc: Optional[str] = None
|
||||
notes: Optional[str] = None
|
||||
_CONFIG_RETIRED = ("retired: change a unit's settings by serial with POST /device/settings/change "
|
||||
"(audited, previewed, read back)")
|
||||
|
||||
|
||||
@app.post("/device/config")
|
||||
def device_config(
|
||||
body: DeviceConfigBody,
|
||||
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
|
||||
baud: int = Query(38400, description="Serial baud rate"),
|
||||
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
|
||||
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
|
||||
serial: Optional[str] = Query(None, description=_SERIAL_CHECK_DOC),
|
||||
) -> dict:
|
||||
"""
|
||||
Read the current device config, apply any supplied changes to the compliance
|
||||
block, and write the full config back.
|
||||
|
||||
Only non-null fields in the JSON body are modified. All other config bytes
|
||||
are round-tripped verbatim from the device.
|
||||
|
||||
Supply either *port* (serial) or *host* (TCP/modem).
|
||||
|
||||
Example body (all fields optional — include only what you want to change):
|
||||
{
|
||||
"recording_mode": 1,
|
||||
"sample_rate": 1024,
|
||||
"record_time": 3.0,
|
||||
"trigger_level_geo": 0.5,
|
||||
"alarm_level_geo": 1.0,
|
||||
"project": "Bridge Inspection 2026",
|
||||
"client_name": "City of Portland",
|
||||
"operator": "Brian Harrison",
|
||||
"seis_loc": "South Abutment",
|
||||
"notes": "Pre-blast baseline"
|
||||
}
|
||||
|
||||
Returns:
|
||||
{"status": "ok", "updated_fields": {...}} on success.
|
||||
|
||||
Raises:
|
||||
502 on protocol errors (timeout, bad ack, etc.).
|
||||
422 if neither port nor host is provided.
|
||||
"""
|
||||
changed = body.model_dump(exclude_none=True)
|
||||
conn_key = _live_cache.make_conn_key(host, tcp_port, port, baud)
|
||||
log.info("POST /device/config port=%s host=%s fields=%s", port, host, list(changed.keys()))
|
||||
|
||||
try:
|
||||
def _do():
|
||||
with _build_client(port, baud, host, tcp_port) as client:
|
||||
info = client.connect()
|
||||
_require_series3(info.serial, serial)
|
||||
client.apply_config(
|
||||
recording_mode=body.recording_mode,
|
||||
sample_rate=body.sample_rate,
|
||||
record_time=body.record_time,
|
||||
histogram_interval_sec=body.histogram_interval_sec,
|
||||
trigger_level_geo=body.trigger_level_geo,
|
||||
alarm_level_geo=body.alarm_level_geo,
|
||||
geo_range=body.geo_range,
|
||||
project=body.project,
|
||||
client_name=body.client_name,
|
||||
operator=body.operator,
|
||||
seis_loc=body.seis_loc,
|
||||
notes=body.notes,
|
||||
)
|
||||
_run_with_retry(_do, is_tcp=_is_tcp(host))
|
||||
except HTTPException:
|
||||
raise
|
||||
except ProtocolError as exc:
|
||||
raise HTTPException(status_code=502, detail=f"Protocol error: {exc}") from exc
|
||||
except OSError as exc:
|
||||
raise HTTPException(status_code=502, detail=f"Connection error: {exc}") from exc
|
||||
except ValueError as exc:
|
||||
raise HTTPException(status_code=422, detail=str(exc)) from exc
|
||||
except Exception as exc:
|
||||
raise HTTPException(status_code=500, detail=f"Device error: {exc}") from exc
|
||||
|
||||
# Config was written to the device — the cached compliance config is now stale.
|
||||
conn_key = SFMCache.make_conn_key(host, tcp_port, port, baud)
|
||||
get_cache().mark_config_dirty(conn_key)
|
||||
|
||||
return {
|
||||
"status": "ok",
|
||||
"updated_fields": changed,
|
||||
}
|
||||
def device_config() -> JSONResponse:
|
||||
"""Retired (phase 5, 2026-11-03). It wrote a MiniMate's settings through an
|
||||
encoder #46 found wrong, unaudited, with no read-back, retrying the whole
|
||||
write on a TCP error. Use POST /device/settings/change."""
|
||||
return JSONResponse(status_code=410, content={"detail": _CONFIG_RETIRED})
|
||||
|
||||
|
||||
# Keep the old endpoint alive under its old URL for anything already calling it
|
||||
@app.post("/device/config/project")
|
||||
def device_config_project(
|
||||
body: DeviceConfigBody,
|
||||
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
|
||||
baud: int = Query(38400, description="Serial baud rate"),
|
||||
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
|
||||
def device_config_project() -> JSONResponse:
|
||||
"""Retired with POST /device/config -- use POST /device/settings/change."""
|
||||
return JSONResponse(status_code=410, content={"detail": _CONFIG_RETIRED})
|
||||
|
||||
|
||||
class SettingsChangeBody(BaseModel):
|
||||
"""POST /device/settings/change. `changes` maps field -> new value, using
|
||||
the field names in GET /device/settings' `detail.editable`. `revision` is the
|
||||
one a dry run (the preview) returned; a live change without it is refused."""
|
||||
changes: Dict[str, Any]
|
||||
revision: Optional[str] = None
|
||||
|
||||
|
||||
@app.post("/device/settings/change")
|
||||
def device_settings_change(
|
||||
body: SettingsChangeBody,
|
||||
serial: str = Query(..., description=_SERIAL_DOC),
|
||||
host: Optional[str] = Query(None, description="TCP host — modem IP"),
|
||||
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
|
||||
serial: Optional[str] = Query(None, description=_SERIAL_CHECK_DOC),
|
||||
) -> dict:
|
||||
"""Deprecated alias for POST /device/config — use that instead."""
|
||||
return device_config(body=body, port=port, baud=baud, host=host, tcp_port=tcp_port, serial=serial)
|
||||
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
|
||||
baud: Optional[int] = Query(None, description="Serial baud rate"),
|
||||
dry_run: bool = Query(False, description="Preview: old -> new and a revision; send nothing"),
|
||||
caller: Optional[str] = Query(None, description="Who is asking (recorded in the audit row)"),
|
||||
):
|
||||
"""Change a unit's settings by serial, both series (spec row 10, phase 5).
|
||||
|
||||
Preview first (`dry_run=true`): it reads the unit and returns, per field, the
|
||||
value it holds and the value it would get, any warnings, anything that blocks
|
||||
the change, and a `revision`. Then send the same body live with that
|
||||
revision: identity read first, refused if the unit is monitoring or its
|
||||
settings changed since the preview (409), sent once, never retried, read back.
|
||||
Statuses as /device/monitor/start; a change that went out but was not
|
||||
confirmed carries `sent` and `audit_id`."""
|
||||
resp = _change_response(lambda: _device_access().change_settings(
|
||||
_unit_address(port, baud, host, tcp_port), serial, changes=body.changes,
|
||||
revision=body.revision, dry_run=dry_run, caller=caller or "api"))
|
||||
if not dry_run:
|
||||
try: # a by-host read must not serve stale settings
|
||||
get_cache().mark_config_dirty(_live_cache.make_conn_key(host, tcp_port, port, baud))
|
||||
except Exception as exc: # noqa: BLE001 -- the change's answer stands
|
||||
log.warning("could not mark the cached config dirty: %s", exc)
|
||||
return resp
|
||||
|
||||
|
||||
# ── Monitoring endpoints ───────────────────────────────────────────────────────
|
||||
|
||||
+11
-2
@@ -1020,8 +1020,18 @@
|
||||
<div id="tab-config" class="tab-pane">
|
||||
|
||||
<div id="cfg-settings" style="display:none; margin-bottom:12px">
|
||||
<div class="cfg-section-title">On the unit (read by serial)</div>
|
||||
<div class="cfg-section-title" id="cfg-settings-title">On the unit (read by serial)</div>
|
||||
<div class="dev-table" id="cfg-settings-table"></div>
|
||||
<!-- Phase 5: change the unit's settings by serial -- Preview, then Send (audited, read back). -->
|
||||
<div class="cfg-section-title" id="cfg-edit-title" hidden>Change settings on this unit</div>
|
||||
<div class="cfg-grid" id="cfg-edit" hidden></div>
|
||||
<div class="cfg-actions" id="cfg-edit-actions" hidden>
|
||||
<button class="btn btn-ghost" id="cfg-preview-btn" disabled>Preview</button>
|
||||
<button class="btn btn-success" id="cfg-send-btn" disabled>Send to Unit</button>
|
||||
<span id="cfg-edit-note"></span>
|
||||
</div>
|
||||
<div class="dev-table" id="cfg-preview"></div>
|
||||
<div class="dev-table" id="cfg-result"></div>
|
||||
</div>
|
||||
|
||||
<div class="cfg-grid" id="cfg-form">
|
||||
@@ -1129,7 +1139,6 @@
|
||||
|
||||
<div class="cfg-actions">
|
||||
<button class="btn btn-ghost" id="cfg-read-btn" onclick="readConfig()" disabled>Read from Device</button>
|
||||
<button class="btn btn-success" id="cfg-write-btn" onclick="writeConfig()" disabled>Write to Device</button>
|
||||
<button class="btn btn-ghost" onclick="clearConfigForm()">Clear Form</button>
|
||||
<span id="cfg-status"></span>
|
||||
</div>
|
||||
|
||||
@@ -47,7 +47,7 @@ const DEVICE_ROUTES = {
|
||||
call_home_state: ['GET', '/device/call_home/state', true],
|
||||
call_home_on: ['POST', '/device/call_home/enable', true],
|
||||
call_home_off: ['POST', '/device/call_home/disable', true],
|
||||
config_write: ['POST', '/device/config', false],
|
||||
settings_change: ['POST', '/device/settings/change', true],
|
||||
event_waveform: ['GET', '/device/event/{index}/waveform', false],
|
||||
event_file: ['GET', '/device/event/{index}/blastware_file', false],
|
||||
};
|
||||
@@ -88,9 +88,9 @@ function controlsFor(unit) {
|
||||
// by host, the legacy read is Series 3's; by serial, both series (phase 4)
|
||||
callHomeRead: series === 3 || (serialMode && series === 4),
|
||||
callHomeChange: serialMode && (series === 3 || series === 4),
|
||||
configWrite: false,
|
||||
configWrite: serialMode && (series === 3 || series === 4),
|
||||
callHomeWrite: false,
|
||||
reasons: { configWrite: 'Coming in phase 5 (#46)',
|
||||
reasons: { configWrite: 'By serial only: Preview, then Send (audited).',
|
||||
callHomeWrite: 'By serial: use Call-home On / Off (audited). Other call-home fields wait for the THOR round.' },
|
||||
};
|
||||
}
|
||||
@@ -101,6 +101,15 @@ function changeSummary(body) {
|
||||
const subs = ((body.plan || {}).steps || []).map(s => s.sub).join(', ');
|
||||
return `${body.action}: dry run — would send ${subs}`;
|
||||
}
|
||||
if (body.action === 'change settings') { // phase 5: the state is a read-back verdict
|
||||
if (body.outcome === 'skipped') return 'change settings: the unit already holds these — nothing sent';
|
||||
if (body.outcome === 'sent' && body.verified === 'ok') {
|
||||
return `change settings: confirmed — the unit holds what was sent (audit ${id8})`;
|
||||
}
|
||||
if (body.verified === 'mismatch') {
|
||||
return `change settings: sent, but the unit reads ${body.state_after} — see what it holds (audit ${id8})`;
|
||||
}
|
||||
}
|
||||
if (body.outcome === 'skipped') return `${body.action}: already ${body.state_before} — nothing sent`;
|
||||
if (body.outcome === 'sent' && body.verified === 'ok') {
|
||||
return `${body.action}: confirmed — ${body.state_before} → ${body.state_after} (audit ${id8})`;
|
||||
@@ -209,4 +218,54 @@ function callHomeRows(state) {
|
||||
: d.reason || `Unknown (byte 5 = ${d.byte5 ?? '?'})`;
|
||||
return [['Call-home', sw], ['Dial string', s.dial_string || '—'], ['Series', s.series]];
|
||||
}
|
||||
// ── The Config tab's edit form, by serial (phase 5) ──────────────────────────
|
||||
|
||||
// The fields the server says this unit can change, in its order, with their
|
||||
// limits (UnitSettings.detail.editable).
|
||||
function settingsFormFields(st) {
|
||||
return (((st || {}).detail || {}).editable || []).map(f => ({ ...f }));
|
||||
}
|
||||
|
||||
// Only what the operator changed, typed as the server expects. Numbers compare
|
||||
// as numbers (0.30 is 0.3); a number that does not parse is left out (the
|
||||
// preview shows exactly what would change); read-only fields never count.
|
||||
function settingsChanges(fields, edited) {
|
||||
const out = {};
|
||||
const e = edited || {};
|
||||
for (const f of fields || []) {
|
||||
if (f.readonly || !(f.field in e)) continue;
|
||||
let v = e[f.field];
|
||||
if (f.kind === 'number' || (f.kind === 'choice' && typeof f.value === 'number')) {
|
||||
if (v === '' || v == null) continue;
|
||||
v = Number(v);
|
||||
if (!Number.isFinite(v) || v === Number(f.value)) continue;
|
||||
} else if (f.kind === 'bool') {
|
||||
v = Boolean(v);
|
||||
if (v === Boolean(f.value)) continue;
|
||||
} else {
|
||||
v = String(v);
|
||||
if (v === String(f.value == null ? '' : f.value)) continue;
|
||||
}
|
||||
out[f.field] = v;
|
||||
}
|
||||
return out;
|
||||
}
|
||||
|
||||
const _dash = v => (v == null || v === '' ? '—' : v);
|
||||
|
||||
// A preview (dry run): one row per field, [label, the unit holds, it would get].
|
||||
function settingsPreviewRows(body) {
|
||||
return Object.values(((body || {}).plan || {}).fields || {}).map(r => [r.label, _dash(r.old), _dash(r.new)]);
|
||||
}
|
||||
|
||||
// Why a preview would not be sent ('' when nothing blocks it).
|
||||
function settingsBlockedText(body) {
|
||||
return (((body || {}).plan || {}).blocked || []).join('; ');
|
||||
}
|
||||
|
||||
// After a send: [label, the unit held, SFM sent, the unit now holds].
|
||||
function settingsResultRows(body) {
|
||||
const fields = ((((body || {}).detail || {}).snapshot || {}).fields) || {};
|
||||
return Object.values(fields).map(r => [r.label, _dash(r.old), _dash(r.new), _dash(r.now)]);
|
||||
}
|
||||
/* </device-routing> */
|
||||
+178
-65
@@ -90,8 +90,7 @@ function applyControls() {
|
||||
badge.textContent = series ? `Series ${series}` : '';
|
||||
document.getElementById('hangup-btn').hidden = !c.hangup;
|
||||
setDiagButtonsEnabled(c.diagnostics);
|
||||
const cw = document.getElementById('cfg-write-btn');
|
||||
cw.disabled = !c.configWrite; cw.title = c.reasons.configWrite;
|
||||
updateSettingsButtons();
|
||||
const hw = document.getElementById('ch-write-btn');
|
||||
hw.disabled = !c.callHomeWrite; hw.title = c.reasons.callHomeWrite;
|
||||
const chr = document.getElementById('ch-read-btn');
|
||||
@@ -163,18 +162,24 @@ async function changeCallHome(on) {
|
||||
await readCallHomeBySerial({ quiet: true });
|
||||
}
|
||||
|
||||
// The Config tab by serial (#6): settings are read-only until phase 5, so the
|
||||
// empty legacy edit form stays hidden and the settings box shows from the start.
|
||||
// A different unit's settings are never left on screen.
|
||||
// The Config tab by serial (#6; phase 5): the settings box shows from the start
|
||||
// and the empty legacy form stays hidden. A different unit's settings, form,
|
||||
// preview or result are never left on screen.
|
||||
let settingsShownFor = null;
|
||||
let settingsShown = null; // the UnitSettings the edit form was built from
|
||||
let settingsPreview = null; // {serial, changes (JSON), revision, blocked}: what a Send would send
|
||||
function applyConfigPanes() {
|
||||
const serial = normSerial(currentUnit().serial);
|
||||
const p = serialPanes(Boolean(serial), Boolean(serial) && settingsShownFor === serial);
|
||||
document.getElementById('cfg-form').style.display = p.configForm ? '' : 'none';
|
||||
document.getElementById('cfg-settings').style.display = p.settingsBox ? 'block' : 'none';
|
||||
if (p.settingsPlaceholder) {
|
||||
settingsShownFor = null;
|
||||
settingsShownFor = null; settingsShown = null; settingsPreview = null;
|
||||
renderTextTable('cfg-settings-table', [['Settings', 'Not read yet — press Read from Device']]);
|
||||
document.getElementById('cfg-settings-title').textContent = 'On the unit (read by serial)';
|
||||
for (const id of ['cfg-edit-title', 'cfg-edit', 'cfg-edit-actions']) document.getElementById(id).hidden = true;
|
||||
renderTextTable('cfg-preview', []);
|
||||
renderTextTable('cfg-result', []);
|
||||
}
|
||||
}
|
||||
|
||||
@@ -783,25 +788,185 @@ function clearConfigForm() {
|
||||
setCfgStatus('');
|
||||
}
|
||||
|
||||
// Serial mode: the shared UnitSettings, read-only (writes wait for phase 5).
|
||||
async function readSettingsBySerial() {
|
||||
// Serial mode: the shared UnitSettings, and the form to change them (phase 5).
|
||||
// `quiet`: the re-read after a send -- the send's own result stays on screen.
|
||||
async function readSettingsBySerial({ quiet = false } = {}) {
|
||||
const btn = document.getElementById('cfg-read-btn');
|
||||
btn.disabled = true;
|
||||
setCfgStatus('Reading settings from the unit…');
|
||||
if (!quiet) setCfgStatus('Reading settings from the unit…');
|
||||
try {
|
||||
const st = await deviceFetch('settings');
|
||||
renderTextTable('cfg-settings-table', settingsRows(st));
|
||||
settingsShownFor = normSerial(st.serial);
|
||||
settingsShown = st;
|
||||
settingsPreview = null;
|
||||
document.getElementById('cfg-settings-title').textContent =
|
||||
`On the unit ${st.serial} — read ${new Date().toTimeString().slice(0, 5)}`;
|
||||
renderSettingsForm(st);
|
||||
renderTextTable('cfg-preview', []);
|
||||
if (!quiet) renderTextTable('cfg-result', []);
|
||||
document.getElementById('cfg-settings').style.display = 'block';
|
||||
document.getElementById('cfg-form').style.display = 'none';
|
||||
setCfgStatus(`Settings read from ${st.serial}.`, 'ok');
|
||||
if (!quiet) setCfgStatus(`Settings read from ${st.serial}.`, 'ok');
|
||||
} catch (e) {
|
||||
setCfgStatus(`Read failed: ${e.message}`, 'error');
|
||||
if (!quiet) setCfgStatus(`Read failed: ${e.message}`, 'error');
|
||||
else renderTextTable('cfg-preview', [['Re-read', `failed: ${e.message}`]]);
|
||||
} finally {
|
||||
btn.disabled = false;
|
||||
updateSettingsButtons();
|
||||
}
|
||||
}
|
||||
|
||||
// ── Changing settings by serial (phase 5) ─────────────────────────────────────
|
||||
|
||||
function settingsInput(f) {
|
||||
let el;
|
||||
if (f.kind === 'choice') {
|
||||
el = document.createElement('select');
|
||||
for (const c of f.choices || []) {
|
||||
const o = document.createElement('option');
|
||||
o.value = String(c.value); o.textContent = c.label;
|
||||
el.appendChild(o);
|
||||
}
|
||||
el.value = String(f.value);
|
||||
} else if (f.kind === 'bool') {
|
||||
el = document.createElement('input');
|
||||
el.type = 'checkbox'; el.checked = Boolean(f.value);
|
||||
} else {
|
||||
el = document.createElement('input');
|
||||
el.type = f.kind === 'number' ? 'number' : 'text';
|
||||
if (f.kind === 'number') {
|
||||
el.step = f.step != null ? String(f.step) : 'any';
|
||||
if (f.min != null) el.min = String(f.min);
|
||||
if (f.max != null) el.max = String(f.max);
|
||||
}
|
||||
if (f.maxlength) el.maxLength = f.maxlength;
|
||||
el.value = f.value == null ? '' : String(f.value);
|
||||
}
|
||||
el.id = `cfg-f-${f.field}`;
|
||||
el.dataset.field = f.field;
|
||||
el.disabled = Boolean(f.readonly);
|
||||
if (f.readonly) el.title = 'Shown, not changed yet';
|
||||
el.addEventListener(f.kind === 'text' || f.kind === 'number' ? 'input' : 'change', settingsEdited);
|
||||
return el;
|
||||
}
|
||||
|
||||
function renderSettingsForm(st) {
|
||||
const box = document.getElementById('cfg-edit');
|
||||
box.innerHTML = '';
|
||||
for (const f of settingsFormFields(st)) {
|
||||
const wrap = document.createElement('div');
|
||||
wrap.className = 'cfg-field';
|
||||
const label = document.createElement('label');
|
||||
label.textContent = f.unit ? `${f.label} (${f.unit})` : f.label;
|
||||
label.htmlFor = `cfg-f-${f.field}`;
|
||||
wrap.append(label, settingsInput(f));
|
||||
box.appendChild(wrap);
|
||||
}
|
||||
for (const id of ['cfg-edit-title', 'cfg-edit', 'cfg-edit-actions']) document.getElementById(id).hidden = false;
|
||||
}
|
||||
|
||||
function editedSettings() {
|
||||
const out = {};
|
||||
for (const el of document.querySelectorAll('#cfg-edit [data-field]')) {
|
||||
out[el.dataset.field] = el.type === 'checkbox' ? el.checked : el.value;
|
||||
}
|
||||
return out;
|
||||
}
|
||||
|
||||
function currentSettingsChanges() {
|
||||
return settingsShown ? settingsChanges(settingsFormFields(settingsShown), editedSettings()) : {};
|
||||
}
|
||||
|
||||
// Any edit after a preview: the preview no longer covers what Send would send.
|
||||
function settingsEdited() {
|
||||
settingsPreview = null;
|
||||
renderTextTable('cfg-preview', []);
|
||||
updateSettingsButtons();
|
||||
}
|
||||
|
||||
function updateSettingsButtons() {
|
||||
const c = controlsFor(currentUnit());
|
||||
const serial = normSerial(currentUnit().serial);
|
||||
const shown = Boolean(settingsShown) && normSerial(settingsShown.serial) === serial;
|
||||
const changes = shown ? currentSettingsChanges() : {};
|
||||
const preview = document.getElementById('cfg-preview-btn');
|
||||
preview.disabled = !(c.configWrite && shown && Object.keys(changes).length) || changeInFlight;
|
||||
preview.title = c.reasons.configWrite;
|
||||
const ready = Boolean(settingsPreview) && settingsPreview.serial === serial && !settingsPreview.blocked
|
||||
&& settingsPreview.changes === JSON.stringify(changes);
|
||||
document.getElementById('cfg-send-btn').disabled = !(c.configWrite && ready) || changeInFlight;
|
||||
}
|
||||
|
||||
function postSettingsChange(changes, { dryRun, revision }) {
|
||||
return deviceRequest('settings_change', dryRun ? { dry_run: 'true' } : {}, {
|
||||
headers: { 'Content-Type': 'application/json' },
|
||||
body: JSON.stringify(revision ? { changes, revision } : { changes }),
|
||||
});
|
||||
}
|
||||
|
||||
// A dry run: SFM re-reads the unit and says what would change. Nothing is sent.
|
||||
async function previewSettings() {
|
||||
const changes = currentSettingsChanges();
|
||||
const serial = normSerial(currentUnit().serial);
|
||||
renderTextTable('cfg-result', []);
|
||||
setCfgStatus('Previewing — reading the unit…');
|
||||
try {
|
||||
const r = await postSettingsChange(changes, { dryRun: true });
|
||||
const body = await r.json().catch(() => ({}));
|
||||
if (!r.ok) {
|
||||
setCfgStatus(changeErrorText('Preview', r.status, body, currentUnit(), r.statusText), 'error');
|
||||
return;
|
||||
}
|
||||
const blocked = settingsBlockedText(body);
|
||||
renderTextTable('cfg-preview', [
|
||||
...settingsPreviewRows(body).map(([label, old, now]) => [label, `${old} → ${now}`]),
|
||||
...((body.plan || {}).warnings || []).map(w => ['Note', w]),
|
||||
...(blocked ? [['Will not send', blocked]] : []),
|
||||
]);
|
||||
settingsPreview = { serial, changes: JSON.stringify(changes), revision: (body.plan || {}).revision,
|
||||
blocked: Boolean(blocked) };
|
||||
setCfgStatus(blocked ? 'Preview: this change cannot be sent (see above). Nothing was sent.'
|
||||
: 'Preview ready — nothing sent yet. Check it, then Send to Unit.',
|
||||
blocked ? 'error' : 'ok');
|
||||
} catch (e) {
|
||||
setCfgStatus(`Preview failed: ${e.message}`, 'error');
|
||||
} finally {
|
||||
updateSettingsButtons();
|
||||
}
|
||||
}
|
||||
|
||||
// One audited send, never retried; the body says what the unit now holds.
|
||||
async function sendSettings() {
|
||||
const p = settingsPreview;
|
||||
if (!p) return;
|
||||
const changes = JSON.parse(p.changes);
|
||||
const names = settingsFormFields(settingsShown).filter(f => f.field in changes).map(f => f.label);
|
||||
if (!confirm(`Send these changes to ${p.serial}?\n\n${names.join('\n')}`)) return;
|
||||
changeInFlight = true; applyControls();
|
||||
setCfgStatus(`Sending to ${p.serial}…`);
|
||||
let body = {};
|
||||
try {
|
||||
const r = await postSettingsChange(changes, { dryRun: false, revision: p.revision });
|
||||
body = await r.json().catch(() => ({}));
|
||||
if (body.outcome) {
|
||||
renderTextTable('cfg-result', settingsResultRows(body).map(
|
||||
([label, old, sent, now]) => [label, `${old} → ${sent} · the unit now holds ${now}`]));
|
||||
setCfgStatus(changeSummary(body), r.ok ? 'ok' : 'error');
|
||||
} else {
|
||||
setCfgStatus(changeErrorText('Change settings', r.status, body, currentUnit(), r.statusText), 'error');
|
||||
}
|
||||
} catch (e) {
|
||||
// No reply is not "nothing sent": the request may have reached the unit.
|
||||
setCfgStatus(`Change settings: no reply from SFM (${e.message}) — it may have been sent; `
|
||||
+ 'read the unit\'s settings and GET /db/device_commands', 'error');
|
||||
}
|
||||
settingsPreview = null;
|
||||
renderTextTable('cfg-preview', []);
|
||||
changeInFlight = false; applyControls();
|
||||
if (body.outcome) await readSettingsBySerial({ quiet: true });
|
||||
}
|
||||
|
||||
async function readConfig() {
|
||||
if (!devHost()) { setCfgStatus('Not connected.', 'error'); return; }
|
||||
if (serialMode()) { await readSettingsBySerial(); return; }
|
||||
@@ -822,60 +987,6 @@ async function readConfig() {
|
||||
}
|
||||
}
|
||||
|
||||
async function writeConfig() {
|
||||
if (!devHost()) { setCfgStatus('Not connected.', 'error'); return; }
|
||||
|
||||
// Build body — only include fields that have values
|
||||
const body = {};
|
||||
const rm = qs('cfg-recording-mode').value;
|
||||
if (rm !== '') body.recording_mode = parseInt(rm, 10);
|
||||
const sr = qs('cfg-sample-rate').value;
|
||||
if (sr) body.sample_rate = parseInt(sr, 10);
|
||||
const hi = qs('cfg-histogram-interval').value;
|
||||
if (hi !== '') body.histogram_interval_sec = parseInt(hi, 10);
|
||||
const rt = qs('cfg-record-time').value;
|
||||
if (rt) body.record_time = parseFloat(rt);
|
||||
const trig = qs('cfg-trigger').value;
|
||||
if (trig) body.trigger_level_geo = parseFloat(trig);
|
||||
const alarm = qs('cfg-alarm').value;
|
||||
if (alarm) body.alarm_level_geo = parseFloat(alarm);
|
||||
const gr = qs('cfg-geo-range').value;
|
||||
if (gr !== '') body.geo_range = parseInt(gr, 10);
|
||||
const proj = qs('cfg-project').value.trim();
|
||||
if (proj) body.project = proj;
|
||||
const cli = qs('cfg-client').value.trim();
|
||||
if (cli) body.client_name = cli;
|
||||
const op = qs('cfg-operator').value.trim();
|
||||
if (op) body.operator = op;
|
||||
const sl = qs('cfg-seis-loc').value.trim();
|
||||
if (sl) body.seis_loc = sl;
|
||||
const notes = qs('cfg-notes').value.trim();
|
||||
if (notes) body.notes = notes;
|
||||
|
||||
if (Object.keys(body).length === 0) {
|
||||
setCfgStatus('No fields to write — fill in at least one field.', 'error');
|
||||
return;
|
||||
}
|
||||
|
||||
const fieldsStr = Object.keys(body).join(', ');
|
||||
setCfgStatus(`Writing ${Object.keys(body).length} field(s)…`);
|
||||
document.getElementById('cfg-write-btn').disabled = true;
|
||||
|
||||
try {
|
||||
await deviceFetch('config_write', {}, {
|
||||
headers: { 'Content-Type': 'application/json' },
|
||||
body: JSON.stringify(body),
|
||||
});
|
||||
setCfgStatus(`Written: ${fieldsStr}`, 'ok');
|
||||
// Re-read device info so Device tab and bar refresh
|
||||
await readConfig();
|
||||
} catch(e) {
|
||||
setCfgStatus(`Write failed: ${e.message}`, 'error');
|
||||
} finally {
|
||||
document.getElementById('cfg-write-btn').disabled = false;
|
||||
}
|
||||
}
|
||||
|
||||
// ── Call Home form ─────────────────────────────────────────────────────────────
|
||||
function setChStatus(msg, type) {
|
||||
const el = document.getElementById('ch-status');
|
||||
@@ -2339,6 +2450,8 @@ for (const id of ['dev-serial', 'dev-host', 'dev-port']) {
|
||||
// New controls are wired here, not with onclick= in the HTML (no inline JS).
|
||||
document.getElementById('ch-on-btn').addEventListener('click', () => changeCallHome(true));
|
||||
document.getElementById('ch-off-btn').addEventListener('click', () => changeCallHome(false));
|
||||
document.getElementById('cfg-preview-btn').addEventListener('click', previewSettings);
|
||||
document.getElementById('cfg-send-btn').addEventListener('click', sendSettings);
|
||||
applyControls();
|
||||
|
||||
// Reflect any persisted mic-unit preference in the header pill on load
|
||||
|
||||
@@ -17,6 +17,59 @@ from minimateplus.models import ComplianceConfig, DeviceInfo, Event, MonitorStat
|
||||
|
||||
SETUP_FIXTURE = Path(__file__).parent / "fixtures" / "micromate-setup" / "um20147_baseline.bin"
|
||||
THOR_IDF = Path(__file__).parent / "fixtures" / "thor-idf"
|
||||
PUSH_FIXTURE = Path(__file__).parent / "fixtures" / "micromate-writes" / "setup-push-overwrite-test1.json"
|
||||
|
||||
|
||||
def s4_push_reads() -> dict:
|
||||
"""UM12947's reads (content, by SUB) just before THOR's setup push: 0x08 prefs,
|
||||
0x2E trigger, 0x1A setup, 0x41 active name."""
|
||||
import json
|
||||
ex = json.loads(PUSH_FIXTURE.read_text())["exchanges"]
|
||||
start = next(i for i, e in enumerate(ex) if e["sub"] == 0xDA)
|
||||
return {e["sub"]: bytes.fromhex(e["response_data"])[11:] for e in ex[:start]}
|
||||
|
||||
|
||||
_S3_BLOCKS = None
|
||||
|
||||
|
||||
def s3_settings_blocks() -> dict:
|
||||
"""BE9441's four settings blocks on 2026-10-26, as SFM's reads return them:
|
||||
the 1A read Blastware took right after its second write (assembled, 2,090 B),
|
||||
and the event index / trigger / waveform blocks that write sent back (each a
|
||||
write is the read plus two bytes)."""
|
||||
global _S3_BLOCKS
|
||||
if _S3_BLOCKS is None:
|
||||
from minimateplus.framing import S3FrameParser
|
||||
from minimateplus.protocol import assemble_compliance_content
|
||||
from test_minimate_write_frames import WRITES, _payload
|
||||
fix = Path(__file__).parent / "fixtures" / "minimate-bench-10-26-26-histogram"
|
||||
reads, cur = [], None
|
||||
for f in S3FrameParser().feed((fix / "unit_replies.bin").read_bytes()):
|
||||
if f.sub != 0xE5:
|
||||
continue
|
||||
if len(f.data) == 11:
|
||||
cur = []
|
||||
reads.append(cur)
|
||||
else:
|
||||
cur.append(bytes(f.data))
|
||||
sent = {_payload(f)[2]: _payload(f)[16:] for f in WRITES[13:26]}
|
||||
_S3_BLOCKS = {"event_index": sent[0x68][:-2], "compliance": assemble_compliance_content(reads[2]),
|
||||
"trigger": sent[0x82][:-2], "waveform": sent[0x69][:-2]}
|
||||
return dict(_S3_BLOCKS)
|
||||
|
||||
|
||||
def s3_device_info_answer(serial: bytes = b"BE9441") -> bytes:
|
||||
"""What a MONITORING MiniMate returns for a 1A read, assembled: its device-info
|
||||
block (BE9441 10-26: reads 3-7 start 0e 'BE9441'), 2,090 bytes."""
|
||||
return (b"\x0e" + serial).ljust(2090, b"\x00")
|
||||
|
||||
|
||||
def schedule_record(time_slot: int, action: int, setup: str = "") -> bytes:
|
||||
"""One 260-byte schedule.dat record (micromate.schedule's layout)."""
|
||||
rec = bytearray(260)
|
||||
rec[4], rec[5], rec[6], rec[7] = time_slot, 3, action, len(setup)
|
||||
rec[8:8 + len(setup)] = setup.encode("ascii")
|
||||
return bytes(rec)
|
||||
THOR_WRITES = Path(__file__).parent / "fixtures" / "micromate-writes"
|
||||
|
||||
|
||||
@@ -97,9 +150,13 @@ def default_s3_events():
|
||||
class FakeMiniMateClient(_Base):
|
||||
def __init__(self, serial="BE18193", *, monitoring=False, compliance="default", events=None,
|
||||
monitor_states=None, write_error=None, serial_reported=None, wake_errors=None,
|
||||
bare_requests_ignored=False, call_home_raw=None, **kw):
|
||||
bare_requests_ignored=False, call_home_raw=None, settings_blocks=None,
|
||||
monitoring_settings=False, **kw):
|
||||
super().__init__(**kw)
|
||||
self.serial = serial
|
||||
self.settings_blocks = s3_settings_blocks() if settings_blocks is None else dict(settings_blocks)
|
||||
self.monitoring_settings = monitoring_settings
|
||||
self.pushed = None
|
||||
# As a monitoring MiniMate (measured 2026-04-08): on a fresh connection a
|
||||
# read before SESSION_RESET + POLL goes unanswered. Off unless a test asks.
|
||||
self.bare_requests_ignored = bare_requests_ignored
|
||||
@@ -165,6 +222,23 @@ class FakeMiniMateClient(_Base):
|
||||
self._write("call_home")
|
||||
self.call_home_raw = bytes(image) # read back as the unit would store it
|
||||
|
||||
def read_compliance_content(self) -> bytes:
|
||||
self._bare_read("read_compliance_content")
|
||||
return s3_device_info_answer() if self.monitoring_settings else self.settings_blocks["compliance"]
|
||||
|
||||
def read_settings_blocks(self) -> dict:
|
||||
self._bare_read("read_settings_blocks")
|
||||
blocks = dict(self.settings_blocks)
|
||||
if self.monitoring_settings:
|
||||
blocks["compliance"] = s3_device_info_answer()
|
||||
return blocks
|
||||
|
||||
def push_config_raw(self, event_index, compliance, trigger, waveform, *, escaped=False) -> None:
|
||||
self.pushed_escaped = escaped
|
||||
self.pushed = (bytes(event_index), bytes(compliance), bytes(trigger), bytes(waveform))
|
||||
self._write("push_config_raw")
|
||||
self.settings_blocks["compliance"] = bytes(compliance)[:2090] # read back as the unit stores it
|
||||
|
||||
def get_monitor_status(self) -> MonitorStatus:
|
||||
self._bare_read("get_monitor_status")
|
||||
state = self.monitor_states.pop(0) if len(self.monitor_states) > 1 else self.monitor_states[0]
|
||||
@@ -269,6 +343,10 @@ class _FakeProtocol:
|
||||
old = self._owner.call_home
|
||||
self._owner.call_home = bytes(st.data[:118]) + bytes(~b & 0xFF for b in old[118:120]) \
|
||||
+ bytes(st.data[120:])
|
||||
if st.sub == 0x71: # the unit stores the setup and computes its own CRC
|
||||
from micromate.setup_block import with_crc
|
||||
old = self._owner.setup
|
||||
self._owner.setup = with_crc(old[:3] + bytes(st.data[3:2090]) + old[2090:2092])
|
||||
return [type("Ack", (), {"sub": s.ack_sub, "data": bytes(11)})() for s in plan.steps]
|
||||
|
||||
def read_call_home_config(self):
|
||||
@@ -279,10 +357,20 @@ class _FakeProtocol:
|
||||
class FakeMicromateClient(_Base):
|
||||
def __init__(self, serial="UM20147", *, monitoring=False, events=5,
|
||||
unsolicited=b"", event_refs=None, run_states=None,
|
||||
serial_reported=None, execute_error=None, call_home=None, **kw):
|
||||
serial_reported=None, execute_error=None, call_home=None, setup=None,
|
||||
prefs=None, trigger=None, active_name=None, schedule_body=None,
|
||||
schedule_error=None, **kw):
|
||||
super().__init__(**kw)
|
||||
self.unit_serial = serial # not `serial`: that is the client's method
|
||||
self.call_home = um12947_call_home() if call_home is None else call_home
|
||||
push = s4_push_reads()
|
||||
self.setup = SETUP_FIXTURE.read_bytes()[11:] if setup is None else setup
|
||||
self.prefs = push[0x08] if prefs is None else prefs
|
||||
self.trigger = push[0x2E] if trigger is None else trigger
|
||||
self.active_name = (push[0x41].split(b"\x00")[0].decode("ascii")
|
||||
if active_name is None else active_name)
|
||||
self.schedule_body = bytes(524) if schedule_body is None else schedule_body
|
||||
self.schedule_error = schedule_error
|
||||
self.run_states = list(run_states) if run_states else [0x00]
|
||||
self.serial_reported = serial if serial_reported is None else serial_reported
|
||||
self.execute_error = execute_error
|
||||
@@ -334,7 +422,29 @@ class FakeMicromateClient(_Base):
|
||||
|
||||
def get_setup(self):
|
||||
self._step("get_setup")
|
||||
return decode_setup(SETUP_FIXTURE.read_bytes()[11:])
|
||||
return decode_setup(self.setup)
|
||||
|
||||
def get_setup_content(self) -> bytes:
|
||||
self._step("get_setup_content")
|
||||
return self.setup
|
||||
|
||||
def get_prefs_content(self) -> bytes:
|
||||
self._step("get_prefs_content")
|
||||
return self.prefs
|
||||
|
||||
def get_trigger_content(self) -> bytes:
|
||||
self._step("get_trigger_content")
|
||||
return self.trigger
|
||||
|
||||
def get_active_setup_raw(self) -> str:
|
||||
self._step("get_active_setup_raw")
|
||||
return self.active_name
|
||||
|
||||
def read_schedule(self) -> bytes:
|
||||
self._step("read_schedule")
|
||||
if self.schedule_error is not None:
|
||||
raise self.schedule_error
|
||||
return self.schedule_body
|
||||
|
||||
def read_unsolicited(self) -> bytes:
|
||||
self._step("read_unsolicited")
|
||||
|
||||
BIN
Binary file not shown.
+116
@@ -0,0 +1,116 @@
|
||||
<?xml version="1.0" encoding="UTF-8"?>
|
||||
<Event>
|
||||
<FileVersion>8.0</FileVersion>
|
||||
<EventType>Full Histogram</EventType>
|
||||
<SerialNumber>BE18190</SerialNumber>
|
||||
<Version>V 10.72-8.17 MiniMate Plus</Version>
|
||||
<FileName>T190LD42.T00H</FileName>
|
||||
<HistogramStartTime>13:29:24</HistogramStartTime>
|
||||
<HistogramStartDate>2025-12-08</HistogramStartDate>
|
||||
<HistogramStopTime>13:29:37</HistogramStopTime>
|
||||
<HistogramStopDate>2025-12-08</HistogramStopDate>
|
||||
<Channels>
|
||||
<Channel>Tran</Channel>
|
||||
<Channel>Vert</Channel>
|
||||
<Channel>Long</Channel>
|
||||
<Channel>MicL</Channel>
|
||||
</Channels>
|
||||
<NumberofIntervals>1.00</NumberofIntervals>
|
||||
<IntervalSize>1 minute</IntervalSize>
|
||||
<SampleRate>2048 sps</SampleRate>
|
||||
<BatteryLevel>6.7 Volts</BatteryLevel>
|
||||
<Calibration>June 13, 2025 by Instantel</Calibration>
|
||||
<Units>in/s and dB(L)</Units>
|
||||
<Project>I-80-North Fork-Area 3-462Richardsvilel</Project>
|
||||
<Client>Fay Company</Client>
|
||||
<UserName>Terra-Mechanics Inc.- Harrison</UserName>
|
||||
<SeisLoc>Loc #8 - Area 3- 462 Richardsville Road</SeisLoc>
|
||||
<GeoRange>
|
||||
<Value>10.000</Value>
|
||||
<Units>in/s</Units>
|
||||
</GeoRange>
|
||||
<TranPPV>
|
||||
<Value>1.280</Value>
|
||||
<Units>in/s</Units>
|
||||
</TranPPV>
|
||||
<VertPPV>
|
||||
<Value>2.615</Value>
|
||||
<Units>in/s</Units>
|
||||
</VertPPV>
|
||||
<LongPPV>
|
||||
<Value>1.120</Value>
|
||||
<Units>in/s</Units>
|
||||
</LongPPV>
|
||||
<TranZCFreq>
|
||||
<Value>15.5</Value>
|
||||
<Units>Hz</Units>
|
||||
</TranZCFreq>
|
||||
<VertZCFreq>
|
||||
<Value>64</Value>
|
||||
<Units>Hz</Units>
|
||||
</VertZCFreq>
|
||||
<LongZCFreq>
|
||||
<Value>17.7</Value>
|
||||
<Units>Hz</Units>
|
||||
</LongZCFreq>
|
||||
<TranPeakTime>13:29:37</TranPeakTime>
|
||||
<TranPeakDate>2025-12-08</TranPeakDate>
|
||||
<VertPeakTime>13:29:37</VertPeakTime>
|
||||
<VertPeakDate>2025-12-08</VertPeakDate>
|
||||
<LongPeakTime>13:29:37</LongPeakTime>
|
||||
<LongPeakDate>2025-12-08</LongPeakDate>
|
||||
<PeakVectorSum>
|
||||
<Value>2.644</Value>
|
||||
<Units>in/s</Units>
|
||||
</PeakVectorSum>
|
||||
<PeakVectorSumTime>13:29:37</PeakVectorSumTime>
|
||||
<PeakVectorSumDate>2025-12-08</PeakVectorSumDate>
|
||||
<Microphone>Linear Weighting</Microphone>
|
||||
<MicLPSPL>
|
||||
<Value>107.0</Value>
|
||||
<Units>dB(L)</Units>
|
||||
</MicLPSPL>
|
||||
<MicLTime>13:29:37</MicLTime>
|
||||
<MicLDate>2025-12-08</MicLDate>
|
||||
<MicLZCFreq>
|
||||
<Value>51</Value>
|
||||
<Units>Hz</Units>
|
||||
</MicLZCFreq>
|
||||
<TranTestFreq>7.4 Hz.</TranTestFreq>
|
||||
<TranTestRatio>4.2</TranTestRatio>
|
||||
<TranTestResults>Passed</TranTestResults>
|
||||
<VertTestFreq>7.6 Hz.</VertTestFreq>
|
||||
<VertTestRatio>3.4</VertTestRatio>
|
||||
<VertTestResults>Passed</VertTestResults>
|
||||
<LongTestFreq>7.3 Hz.</LongTestFreq>
|
||||
<LongTestRatio>3.7</LongTestRatio>
|
||||
<LongTestResults>Passed</LongTestResults>
|
||||
<MicLTestFreq>0.0 Hz.</MicLTestFreq>
|
||||
<MicLTestAmplitude>0 mv</MicLTestAmplitude>
|
||||
<MicLTestResults>Check</MicLTestResults>
|
||||
<UsbSummaryChannels>
|
||||
</UsbSummaryChannels>
|
||||
<MonitorLog>2025-12-08 13:29:23 - 2025-12-08 13:29:37 "Event Recorded Modem Exit"</MonitorLog>
|
||||
<HistogramData>
|
||||
<HistogramDataColumnTitle>
|
||||
<ColumnTitle> Tran Peak in/s </ColumnTitle>
|
||||
<ColumnTitle> Tran Freq Hz </ColumnTitle>
|
||||
<ColumnTitle> Vert Peak in/s </ColumnTitle>
|
||||
<ColumnTitle> Vert Freq Hz </ColumnTitle>
|
||||
<ColumnTitle> Long Peak in/s </ColumnTitle>
|
||||
<ColumnTitle> Long Freq Hz </ColumnTitle>
|
||||
<ColumnTitle> Geo PVS in/s </ColumnTitle>
|
||||
<ColumnTitle> MicL Peak psi(L) </ColumnTitle>
|
||||
<ColumnTitle> MicL Peak dB(L) </ColumnTitle>
|
||||
<ColumnTitle> MicL Freq Hz </ColumnTitle>
|
||||
</HistogramDataColumnTitle>
|
||||
<HistogramDataIntervals>
|
||||
<Time>2025-12-08 13:29:37</Time>
|
||||
<Row>
|
||||
<Cell>1.280</Cell><Cell>15.5</Cell><Cell>2.615</Cell><Cell>64</Cell><Cell>1.120</Cell><Cell>17.7</Cell><Cell>2.644</Cell><Cell>0.001</Cell><Cell>107.0</Cell><Cell>51</Cell></Row>
|
||||
</HistogramDataIntervals>
|
||||
</HistogramData>
|
||||
<HistogramDataUsbChannels>
|
||||
</HistogramDataUsbChannels>
|
||||
|
||||
</Event>
|
||||
BIN
Binary file not shown.
+116
@@ -0,0 +1,116 @@
|
||||
<?xml version="1.0" encoding="UTF-8"?>
|
||||
<Event>
|
||||
<FileVersion>8.0</FileVersion>
|
||||
<EventType>Full Histogram</EventType>
|
||||
<SerialNumber>BE18190</SerialNumber>
|
||||
<Version>V 10.72-8.17 MiniMate Plus</Version>
|
||||
<FileName>T190LD5Q.LD0H</FileName>
|
||||
<HistogramStartTime>11:00:49</HistogramStartTime>
|
||||
<HistogramStartDate>2025-12-09</HistogramStartDate>
|
||||
<HistogramStopTime>11:00:59</HistogramStopTime>
|
||||
<HistogramStopDate>2025-12-09</HistogramStopDate>
|
||||
<Channels>
|
||||
<Channel>Tran</Channel>
|
||||
<Channel>Vert</Channel>
|
||||
<Channel>Long</Channel>
|
||||
<Channel>MicL</Channel>
|
||||
</Channels>
|
||||
<NumberofIntervals>1.00</NumberofIntervals>
|
||||
<IntervalSize>1 minute</IntervalSize>
|
||||
<SampleRate>1024 sps</SampleRate>
|
||||
<BatteryLevel>6.9 Volts</BatteryLevel>
|
||||
<Calibration>June 13, 2025 by Instantel</Calibration>
|
||||
<Units>in/s and dB(L)</Units>
|
||||
<Project>I-80-North Fork-Area 3-462Richardsvilel</Project>
|
||||
<Client>Fay Company</Client>
|
||||
<UserName>Terra-Mechanics Inc.- Harrison</UserName>
|
||||
<SeisLoc>Loc #8 - Area 3- 462 Richardsville Road</SeisLoc>
|
||||
<GeoRange>
|
||||
<Value>10.000</Value>
|
||||
<Units>in/s</Units>
|
||||
</GeoRange>
|
||||
<TranPPV>
|
||||
<Value>2.140</Value>
|
||||
<Units>in/s</Units>
|
||||
</TranPPV>
|
||||
<VertPPV>
|
||||
<Value>OORANGE</Value>
|
||||
<Units>in/s</Units>
|
||||
</VertPPV>
|
||||
<LongPPV>
|
||||
<Value>2.830</Value>
|
||||
<Units>in/s</Units>
|
||||
</LongPPV>
|
||||
<TranZCFreq>
|
||||
<Value>>100</Value>
|
||||
<Units>Hz</Units>
|
||||
</TranZCFreq>
|
||||
<VertZCFreq>
|
||||
<Value>85</Value>
|
||||
<Units>Hz</Units>
|
||||
</VertZCFreq>
|
||||
<LongZCFreq>
|
||||
<Value>34</Value>
|
||||
<Units>Hz</Units>
|
||||
</LongZCFreq>
|
||||
<TranPeakTime>11:00:59</TranPeakTime>
|
||||
<TranPeakDate>2025-12-09</TranPeakDate>
|
||||
<VertPeakTime>11:00:59</VertPeakTime>
|
||||
<VertPeakDate>2025-12-09</VertPeakDate>
|
||||
<LongPeakTime>11:00:59</LongPeakTime>
|
||||
<LongPeakDate>2025-12-09</LongPeakDate>
|
||||
<PeakVectorSum>
|
||||
<Value>OORANGE</Value>
|
||||
<Units>in/s</Units>
|
||||
</PeakVectorSum>
|
||||
<PeakVectorSumTime>11:00:59</PeakVectorSumTime>
|
||||
<PeakVectorSumDate>2025-12-09</PeakVectorSumDate>
|
||||
<Microphone>Linear Weighting</Microphone>
|
||||
<MicLPSPL>
|
||||
<Value>106.0</Value>
|
||||
<Units>dB(L)</Units>
|
||||
</MicLPSPL>
|
||||
<MicLTime>11:00:59</MicLTime>
|
||||
<MicLDate>2025-12-09</MicLDate>
|
||||
<MicLZCFreq>
|
||||
<Value>85</Value>
|
||||
<Units>Hz</Units>
|
||||
</MicLZCFreq>
|
||||
<TranTestFreq>7.4 Hz.</TranTestFreq>
|
||||
<TranTestRatio>4.4</TranTestRatio>
|
||||
<TranTestResults>Passed</TranTestResults>
|
||||
<VertTestFreq>7.6 Hz.</VertTestFreq>
|
||||
<VertTestRatio>3.5</VertTestRatio>
|
||||
<VertTestResults>Passed</VertTestResults>
|
||||
<LongTestFreq>7.3 Hz.</LongTestFreq>
|
||||
<LongTestRatio>3.9</LongTestRatio>
|
||||
<LongTestResults>Passed</LongTestResults>
|
||||
<MicLTestFreq>20.5 Hz.</MicLTestFreq>
|
||||
<MicLTestAmplitude>691 mv</MicLTestAmplitude>
|
||||
<MicLTestResults>Passed</MicLTestResults>
|
||||
<UsbSummaryChannels>
|
||||
</UsbSummaryChannels>
|
||||
<MonitorLog>2025-12-09 11:00:48 - 2025-12-09 11:00:59 "Event Recorded Modem Exit"</MonitorLog>
|
||||
<HistogramData>
|
||||
<HistogramDataColumnTitle>
|
||||
<ColumnTitle> Tran Peak in/s </ColumnTitle>
|
||||
<ColumnTitle> Tran Freq Hz </ColumnTitle>
|
||||
<ColumnTitle> Vert Peak in/s </ColumnTitle>
|
||||
<ColumnTitle> Vert Freq Hz </ColumnTitle>
|
||||
<ColumnTitle> Long Peak in/s </ColumnTitle>
|
||||
<ColumnTitle> Long Freq Hz </ColumnTitle>
|
||||
<ColumnTitle> Geo PVS in/s </ColumnTitle>
|
||||
<ColumnTitle> MicL Peak psi(L) </ColumnTitle>
|
||||
<ColumnTitle> MicL Peak dB(L) </ColumnTitle>
|
||||
<ColumnTitle> MicL Freq Hz </ColumnTitle>
|
||||
</HistogramDataColumnTitle>
|
||||
<HistogramDataIntervals>
|
||||
<Time>2025-12-09 11:00:59</Time>
|
||||
<Row>
|
||||
<Cell>2.140</Cell><Cell>>100</Cell><Cell>OORANGE</Cell><Cell>85</Cell><Cell>2.830</Cell><Cell>34</Cell><Cell>OORANGE</Cell><Cell>0.001</Cell><Cell>106.0</Cell><Cell>85</Cell></Row>
|
||||
</HistogramDataIntervals>
|
||||
</HistogramData>
|
||||
<HistogramDataUsbChannels>
|
||||
</HistogramDataUsbChannels>
|
||||
|
||||
</Event>
|
||||
BIN
Binary file not shown.
+116
@@ -0,0 +1,116 @@
|
||||
<?xml version="1.0" encoding="UTF-8"?>
|
||||
<Event>
|
||||
<FileVersion>8.0</FileVersion>
|
||||
<EventType>Full Histogram</EventType>
|
||||
<SerialNumber>BE9558</SerialNumber>
|
||||
<Version>V 10.72-8.17 MiniMate Plus</Version>
|
||||
<FileName>K558L4KY.440H</FileName>
|
||||
<HistogramStartTime>17:04:52</HistogramStartTime>
|
||||
<HistogramStartDate>2025-06-25</HistogramStartDate>
|
||||
<HistogramStopTime>17:05:39</HistogramStopTime>
|
||||
<HistogramStopDate>2025-06-25</HistogramStopDate>
|
||||
<Channels>
|
||||
<Channel>Tran</Channel>
|
||||
<Channel>Vert</Channel>
|
||||
<Channel>Long</Channel>
|
||||
<Channel>MicL</Channel>
|
||||
</Channels>
|
||||
<NumberofIntervals>1.00</NumberofIntervals>
|
||||
<IntervalSize>5 minutes</IntervalSize>
|
||||
<SampleRate>1024 sps</SampleRate>
|
||||
<BatteryLevel>6.3 Volts</BatteryLevel>
|
||||
<Calibration>June 13, 2025 by Instantel</Calibration>
|
||||
<Units>in/s and dB(L)</Units>
|
||||
<Project>Fay - Locks & Dam No3 -Loc 5 Synthomer</Project>
|
||||
<Client>Fay Company</Client>
|
||||
<UserName>Terra-Mechanics Inc - Harrison</UserName>
|
||||
<Seis.Loc>Location #5 Sythomer Plant</Seis.Loc>
|
||||
<GeoRange>
|
||||
<Value>10.000</Value>
|
||||
<Units>in/s</Units>
|
||||
</GeoRange>
|
||||
<TranPPV>
|
||||
<Value>2.315</Value>
|
||||
<Units>in/s</Units>
|
||||
</TranPPV>
|
||||
<VertPPV>
|
||||
<Value>2.715</Value>
|
||||
<Units>in/s</Units>
|
||||
</VertPPV>
|
||||
<LongPPV>
|
||||
<Value>5.115</Value>
|
||||
<Units>in/s</Units>
|
||||
</LongPPV>
|
||||
<TranZCFreq>
|
||||
<Value>10</Value>
|
||||
<Units>Hz</Units>
|
||||
</TranZCFreq>
|
||||
<VertZCFreq>
|
||||
<Value>85</Value>
|
||||
<Units>Hz</Units>
|
||||
</VertZCFreq>
|
||||
<LongZCFreq>
|
||||
<Value>19</Value>
|
||||
<Units>Hz</Units>
|
||||
</LongZCFreq>
|
||||
<TranPeakTime>17:05:39</TranPeakTime>
|
||||
<TranPeakDate>2025-06-25</TranPeakDate>
|
||||
<VertPeakTime>17:05:39</VertPeakTime>
|
||||
<VertPeakDate>2025-06-25</VertPeakDate>
|
||||
<LongPeakTime>17:05:39</LongPeakTime>
|
||||
<LongPeakDate>2025-06-25</LongPeakDate>
|
||||
<PeakVectorSum>
|
||||
<Value>5.559</Value>
|
||||
<Units>in/s</Units>
|
||||
</PeakVectorSum>
|
||||
<PeakVectorSumTime>17:05:39</PeakVectorSumTime>
|
||||
<PeakVectorSumDate>2025-06-25</PeakVectorSumDate>
|
||||
<Microphone>Linear Weighting</Microphone>
|
||||
<MicLPSPL>
|
||||
<Value>111.8</Value>
|
||||
<Units>dB(L)</Units>
|
||||
</MicLPSPL>
|
||||
<MicLTime>17:05:39</MicLTime>
|
||||
<MicLDate>2025-06-25</MicLDate>
|
||||
<MicLZCFreq>
|
||||
<Value>43</Value>
|
||||
<Units>Hz</Units>
|
||||
</MicLZCFreq>
|
||||
<TranTestFreq>7.7 Hz.</TranTestFreq>
|
||||
<TranTestRatio>3.9</TranTestRatio>
|
||||
<TranTestResults>Passed</TranTestResults>
|
||||
<VertTestFreq>7.5 Hz.</VertTestFreq>
|
||||
<VertTestRatio>3.8</VertTestRatio>
|
||||
<VertTestResults>Passed</VertTestResults>
|
||||
<LongTestFreq>7.5 Hz.</LongTestFreq>
|
||||
<LongTestRatio>3.7</LongTestRatio>
|
||||
<LongTestResults>Passed</LongTestResults>
|
||||
<MicLTestFreq>0.0 Hz.</MicLTestFreq>
|
||||
<MicLTestAmplitude>0 mv</MicLTestAmplitude>
|
||||
<MicLTestResults>Check</MicLTestResults>
|
||||
<UsbSummaryChannels>
|
||||
</UsbSummaryChannels>
|
||||
<MonitorLog>2025-06-25 17:04:51 - 2025-06-25 17:05:39 "Event Recorded Modem Exit"</MonitorLog>
|
||||
<HistogramData>
|
||||
<HistogramDataColumnTitle>
|
||||
<ColumnTitle> Tran Peak in/s </ColumnTitle>
|
||||
<ColumnTitle> Tran Freq Hz </ColumnTitle>
|
||||
<ColumnTitle> Vert Peak in/s </ColumnTitle>
|
||||
<ColumnTitle> Vert Freq Hz </ColumnTitle>
|
||||
<ColumnTitle> Long Peak in/s </ColumnTitle>
|
||||
<ColumnTitle> Long Freq Hz </ColumnTitle>
|
||||
<ColumnTitle> Geo PVS in/s </ColumnTitle>
|
||||
<ColumnTitle> MicL Peak psi(L) </ColumnTitle>
|
||||
<ColumnTitle> MicL Peak dB(L) </ColumnTitle>
|
||||
<ColumnTitle> MicL Freq Hz </ColumnTitle>
|
||||
</HistogramDataColumnTitle>
|
||||
<HistogramDataIntervals>
|
||||
<Time>2025-06-25 17:05:39</Time>
|
||||
<Row>
|
||||
<Cell>2.315</Cell><Cell>10</Cell><Cell>2.715</Cell><Cell>85</Cell><Cell>5.115</Cell><Cell>19</Cell><Cell>5.559</Cell><Cell>0.001</Cell><Cell>111.8</Cell><Cell>43</Cell></Row>
|
||||
</HistogramDataIntervals>
|
||||
</HistogramData>
|
||||
<HistogramDataUsbChannels>
|
||||
</HistogramDataUsbChannels>
|
||||
|
||||
</Event>
|
||||
BIN
Binary file not shown.
BIN
Binary file not shown.
+3978
File diff suppressed because it is too large.
Load diff
BIN
Binary file not shown.
+3975
File diff suppressed because it is too large.
Load diff
@@ -141,10 +141,12 @@ def test_a_report_fills_in_when_the_record_is_missing():
|
||||
assert (_dt(ev.timestamp), ev.timestamp_source) == (TRIGGER, "report")
|
||||
|
||||
|
||||
def test_a_histogram_keeps_its_footer_start_for_now():
|
||||
# Its record (marker fe f5) also holds Blastware's start -- that change is #51.
|
||||
def test_a_histogram_takes_its_event_records_start():
|
||||
# #51: its record (marker fe f5) holds Blastware's start; the footer's
|
||||
# 19:04:50 is a second early.
|
||||
ev = read_blastware_file(HISTOGRAM)
|
||||
assert (_dt(ev.timestamp), ev.timestamp_source) == (datetime.datetime(2026, 5, 10, 19, 4, 50), "footer")
|
||||
assert (_dt(ev.timestamp), ev.timestamp_source) == (datetime.datetime(2026, 5, 10, 19, 4, 51),
|
||||
"event_record")
|
||||
|
||||
|
||||
def test_the_sidecar_keeps_the_instruments_time_and_says_where_it_came_from():
|
||||
@@ -173,13 +175,16 @@ def test_an_imported_event_with_only_an_estimate_does_not_overwrite_its_neighbou
|
||||
from sfm.database import SeismoDb
|
||||
from sfm.waveform_store import WaveformStore
|
||||
store, db = WaveformStore(tmp_path / "waveforms"), SeismoDb(tmp_path / "seismo_relay.db")
|
||||
other = Event(index=0) # a different event at 14:23:43
|
||||
# A different waveform at 14:23:43. The key is unit + time + type (#51), so
|
||||
# "its neighbour" is an event of the same type at the same second.
|
||||
other = Event(index=0)
|
||||
other.timestamp = Timestamp(raw=b"", flag=0x10, year=2026, unknown_byte=0, month=10, day=26,
|
||||
hour=14, minute=23, second=43)
|
||||
other._waveform_key = bytes.fromhex("01110000")
|
||||
other.record_type = "Waveform"
|
||||
other.peak_values = PeakValues(tran=0.01, vert=0.02, long=0.03, peak_vector_sum=0.04, micl=None)
|
||||
db.insert_events([other], serial="BE9441", device_family="series3",
|
||||
waveform_records={"01110000": {"filename": "K441LTOF.ZJ0H"}})
|
||||
waveform_records={"01110000": {"filename": "K441LTOF.ZJ0W"}})
|
||||
|
||||
broken = bytes(_broken(lambda r, i: r.__setitem__(i + 1, 0x81))) # no validated record
|
||||
ev, rec = store.save_imported_bw(broken, source_path=Path(ZI0.name))
|
||||
@@ -189,6 +194,31 @@ def test_an_imported_event_with_only_an_estimate_does_not_overwrite_its_neighbou
|
||||
waveform_records={ev._waveform_key.hex(): rec}) == (0, 1)
|
||||
with sqlite3.connect(str(db.db_path)) as c:
|
||||
assert c.execute("SELECT blastware_filename, peak_vector_sum FROM events").fetchall() == \
|
||||
[("K441LTOF.ZJ0H", 0.04)]
|
||||
[("K441LTOF.ZJ0W", 0.04)]
|
||||
assert (tmp_path / "waveforms" / "BE9441" / "K441LTOF.ZI0").exists() # the data is kept
|
||||
assert any("not merged" in r.message for r in caplog.records)
|
||||
|
||||
|
||||
def test_an_estimate_beside_a_histogram_at_its_second_is_stored_alongside(tmp_path):
|
||||
# A waveform and a histogram may share a second (#51): the estimate is its
|
||||
# own row, and the histogram is untouched.
|
||||
import sqlite3
|
||||
from minimateplus.models import Event, PeakValues, Timestamp
|
||||
from sfm.database import SeismoDb
|
||||
from sfm.waveform_store import WaveformStore
|
||||
store, db = WaveformStore(tmp_path / "waveforms"), SeismoDb(tmp_path / "seismo_relay.db")
|
||||
hist = Event(index=0)
|
||||
hist.timestamp = Timestamp(raw=b"", flag=0x10, year=2026, unknown_byte=0, month=10, day=26,
|
||||
hour=14, minute=23, second=43)
|
||||
hist._waveform_key = bytes.fromhex("01110000")
|
||||
hist.record_type = "Histogram"
|
||||
hist.peak_values = PeakValues(tran=0.01, vert=0.02, long=0.03, peak_vector_sum=0.04, micl=None)
|
||||
db.insert_events([hist], serial="BE9441", device_family="series3",
|
||||
waveform_records={"01110000": {"filename": "K441LTOF.ZJ0H"}})
|
||||
broken = bytes(_broken(lambda r, i: r.__setitem__(i + 1, 0x81))) # no validated record
|
||||
ev, rec = store.save_imported_bw(broken, source_path=Path(ZI0.name))
|
||||
assert db.insert_events([ev], serial="BE9441", device_family="series3",
|
||||
waveform_records={ev._waveform_key.hex(): rec}) == (1, 0)
|
||||
with sqlite3.connect(str(db.db_path)) as c:
|
||||
rows = c.execute("SELECT record_type, peak_vector_sum FROM events ORDER BY record_type").fetchall()
|
||||
assert rows[0] == ("Histogram", 0.04) and rows[1][0] == "Waveform"
|
||||
@@ -365,3 +365,160 @@ def test_a_waveform_with_the_early_record_is_timed_from_its_trigger():
|
||||
# Blastware: 2019-09-26 11:14:08, record time 4 s (SFM read the stop, 11:14:12)
|
||||
assert (ts.year, ts.month, ts.day, ts.hour, ts.minute, ts.second) == (2019, 9, 26, 11, 14, 8)
|
||||
assert ev.timestamp_source in ("event_record", "estimate")
|
||||
|
||||
|
||||
# ── Group A: identity, battery, trigger ─────────────────────────────────────
|
||||
# The identity block before the setup name is what the live read gets from
|
||||
# SUB FE (DeviceInfo): serial k-202, firmware k-147, DSP version k-138,
|
||||
# calibration date k-132 and "by" k-128, manufacturer k-94, model k-72; the
|
||||
# battery is a uint16 of hundredths of a volt at k-190. Measured against every
|
||||
# DL2 report 2026-11-03 (serial, version, calibration 69,983 / 69,983).
|
||||
import datetime as _dt # noqa: E402
|
||||
|
||||
_SF = "setup-fields-11-03-26"
|
||||
|
||||
|
||||
def test_the_identity_block_is_read():
|
||||
# Blastware: BE18189, "V 10.72-8.17 MiniMate Plus",
|
||||
# "February 20, 2019 by Instantel", "6.8 Volts"
|
||||
ev = read_blastware_file(_FIX / _SF / "T189HUD6.QE0W")
|
||||
di = ev.device_info
|
||||
assert (di.serial, di.firmware_version, di.dsp_version, di.manufacturer, di.model) == (
|
||||
"BE18189", "S338.17", "10.72", "Instantel", "MiniMate Plus")
|
||||
assert di.firmware_minor == 17
|
||||
assert (di.calibration_date, di.calibrated_by) == (_dt.date(2019, 2, 20), "Instantel")
|
||||
assert abs(ev.battery_volts - 6.8) <= 0.05 + 1e-9
|
||||
|
||||
|
||||
def test_the_battery_is_kept_exact():
|
||||
# Blastware prints "6.3 Volts" for a stored 6.25: it rounds half up.
|
||||
assert read_blastware_file(_FIX / _SF / "K558L4KY.440H").battery_volts == 6.25
|
||||
|
||||
|
||||
# (file, Blastware's Trigger as the event record's bitmask, geo level in/s,
|
||||
# mic level psi or None, mic a trigger source)
|
||||
@pytest.mark.parametrize("rel,by,geo,mic_psi,mic_src", [
|
||||
(f"{_SF}/T189HUD6.QE0W", 0x0008, 0.050, 0.0072, True), # MicL, 128.0 dB(L)
|
||||
(f"{_SF}/T438L713.RY0W", 0x0002, 0.500, 0.0100, True), # Vert, 130.8 dB(L)
|
||||
(f"{_SF}/M529I6LG.3Y0W", 0x0004, 0.050, 0.005, True), # Long, 0.005 psi(L)
|
||||
("bw-import-fields-10-29-26/R352HIUI.F40W", 0x0001, 0.400, None, False), # Tran
|
||||
("decode-checker-10-29-26/T1905KDW.5F0W", 0x0200, None, None, None), # Manual
|
||||
])
|
||||
def test_the_trigger_comes_from_the_file(rel, by, geo, mic_psi, mic_src):
|
||||
ev = read_blastware_file(_FIX / rel)
|
||||
assert ev.triggered_by == by
|
||||
if geo is not None:
|
||||
assert abs(ev.trigger_level_geo - geo) <= 0.0005 + 1e-9
|
||||
if mic_psi is not None:
|
||||
assert abs(ev.trigger_level_mic_psi - mic_psi) <= 0.0005 + 1e-9 # psi to 3 places, as printed
|
||||
if mic_src is not None:
|
||||
assert bool(ev.trigger_sources & 0x08) == mic_src
|
||||
assert (ev.record_stop_mode, ev.mic_type) == (0, 2) # Fixed, Linear Weighting
|
||||
|
||||
|
||||
def test_the_h5_carries_the_setup_fields(tmp_path):
|
||||
import h5py
|
||||
from sfm import event_hdf5
|
||||
ev = read_blastware_file(_FIX / _SF / "T189HUD6.QE0W")
|
||||
event_hdf5.write_event_hdf5(tmp_path / "e.h5", ev, serial="BE18189")
|
||||
with h5py.File(tmp_path / "e.h5", "r") as f:
|
||||
a = f.attrs
|
||||
assert abs(float(a["battery_volts"]) - 6.8) <= 0.05 + 1e-9
|
||||
assert (int(a["triggered_by"]), int(a["trigger_sources"])) == (0x0008, ev.trigger_sources)
|
||||
assert abs(float(a["trigger_level_geo_ips"]) - 0.050) <= 0.0005 + 1e-9
|
||||
assert abs(float(a["trigger_level_mic_psi"]) - ev.trigger_level_mic_psi) < 1e-9
|
||||
assert (str(a["firmware_version"]), str(a["dsp_version"]), str(a["calibration_date"])) == (
|
||||
"S338.17", "10.72", "2019-02-20")
|
||||
|
||||
|
||||
# ── Group B: histogram interval detail ──────────────────────────────────────
|
||||
# Interval size is the setup's uint16 seconds at k - 40 (Series IV [8:10]); the
|
||||
# stop is the footer's. Each interval keeps its half-periods and its vector sum
|
||||
# (PVS^2). Frequency = (sample rate / 2) / half-period: 527,915 / 527,915 cells
|
||||
# at 1024 sps and 1,725 / 1,725 at 2048 (#50: the old fixed 512 halved every
|
||||
# 2048-sps frequency). Measured 2026-11-03.
|
||||
from minimateplus.histogram_codec import half_period_to_hz # noqa: E402
|
||||
|
||||
_HB = "histogram-intervals-11-03-26"
|
||||
|
||||
|
||||
@pytest.mark.parametrize("rel,sr,freqs,pvs,stop", [
|
||||
# Blastware: 1 minute; Tran 32, Vert 47, Long 14, MicL 47 Hz; PVS 1.358; stop 12:49:33
|
||||
("decode-checker-10-29-26/T004JTRF.ME0H", 1024,
|
||||
{"Tran": 32, "Vert": 47, "Long": 14, "MicL": 47}, 1.358, (2022, 12, 28, 12, 49, 33)),
|
||||
# Blastware: 1 minute at 2048 sps; Tran 15.5, Vert 64, Long 17.7, MicL 51 Hz; PVS 2.644
|
||||
(f"{_HB}/T190LD42.T00H", 2048,
|
||||
{"Tran": 15.5, "Vert": 64, "Long": 17.7, "MicL": 51}, 2.644, (2025, 12, 8, 13, 29, 37)),
|
||||
])
|
||||
def test_histogram_interval_detail_comes_from_the_file(rel, sr, freqs, pvs, stop):
|
||||
ev = read_blastware_file(_FIX / rel)
|
||||
assert (ev.sample_rate, ev.histogram_interval_sec) == (sr, 60)
|
||||
for ch, hz in freqs.items():
|
||||
got = half_period_to_hz(ev.interval_half_periods[ch][0], ev.sample_rate)
|
||||
d = 1 if isinstance(hz, float) else 0
|
||||
assert abs(got - hz) <= 0.5 * 10 ** -d + 1e-9, (ch, got, hz)
|
||||
assert abs(ev.interval_pvs[0] - pvs) <= 0.0005 + 1e-9
|
||||
t = ev.stop_time
|
||||
assert (t.year, t.month, t.day, t.hour, t.minute, t.second) == stop
|
||||
|
||||
|
||||
def test_the_h5_carries_the_interval_detail(tmp_path):
|
||||
import h5py
|
||||
from sfm import event_hdf5
|
||||
ev = read_blastware_file(_FIX / _HB / "T190LD42.T00H")
|
||||
event_hdf5.write_event_hdf5(tmp_path / "e.h5", ev, serial="BE18190")
|
||||
with h5py.File(tmp_path / "e.h5", "r") as f:
|
||||
assert int(f.attrs["histogram_interval_sec"]) == 60
|
||||
assert list(f["intervals/half_period/Vert"][:]) == ev.interval_half_periods["Vert"]
|
||||
assert abs(float(f["intervals/pvs_ips"][0]) - 2.644) <= 0.0005 + 1e-9
|
||||
|
||||
|
||||
# ── #51: a histogram's start and stop from its own event record ─────────────
|
||||
# The footer's start runs a second early on 97%. The histogram's event record
|
||||
# (lead 00 28 05 00, source 04 00, marker fe f5) holds Blastware's start and
|
||||
# stop: 63,490 / 63,490 DL2 histograms each (2026-11-03).
|
||||
|
||||
def test_a_histogram_starts_at_its_event_records_start():
|
||||
ev = read_blastware_file(_FIX / "decode-checker-10-29-26/T004JTRF.ME0H")
|
||||
t, s = ev.timestamp, ev.stop_time
|
||||
# Blastware: start 2022-12-28 12:49:26, stop 12:49:33
|
||||
assert (t.year, t.month, t.day, t.hour, t.minute, t.second) == (2022, 12, 28, 12, 49, 26)
|
||||
assert (s.hour, s.minute, s.second) == (12, 49, 33)
|
||||
assert ev.timestamp_source == "event_record"
|
||||
|
||||
|
||||
def test_a_histogram_without_its_record_falls_back_to_the_footer_and_says_so():
|
||||
raw = bytearray((_FIX / "decode-checker-10-29-26/T004JTRF.ME0H").read_bytes())
|
||||
i = raw.find(b"\xfe\xf5")
|
||||
raw[i] = 0x00 # break the record's marker
|
||||
ev = decode_blastware_bytes(bytes(raw), name=None)
|
||||
assert ev.timestamp_source == "footer"
|
||||
assert ev.timestamp.second == 25 # the footer's start, a second early
|
||||
assert any("histogram event record" in p for p in ev.decode_problems)
|
||||
|
||||
|
||||
# ── Group D, part 1: time of peak, vector-sum time, peak acceleration ───────
|
||||
# Measured on 400 DL2 waveforms (2026-11-04):
|
||||
# time of peak = (peak sample - pre-trigger samples) / sample rate: 1,197 / 1,197
|
||||
# vector-sum time, the same on sqrt(T^2 + V^2 + L^2): 398 / 399
|
||||
# peak acceleration = largest |v[i+1] - v[i]| x rate / g, with Blastware's g
|
||||
# fitted to [386.2236, 386.2240] in/s^2 by every DL2 value: 19,475 / 19,479
|
||||
|
||||
@pytest.mark.parametrize("rel,times,pvs_time,accel", [
|
||||
(f"{_SF}/T189HUD6.QE0W",
|
||||
{"tran": 0.004, "vert": 0.001, "long": 0.024, "micl": 0.003}, 0.016, (0.027, 0.013, 0.027)),
|
||||
("decode-checker-10-29-26/R352HIUI.F40W",
|
||||
{"tran": 0.000, "vert": 0.000, "long": 0.000, "micl": 0.005}, 0.000, (1.617, 0.278, 0.318)),
|
||||
])
|
||||
def test_waveform_peak_detail_comes_from_the_samples(rel, times, pvs_time, accel):
|
||||
pv = read_blastware_file(_FIX / rel).peak_values
|
||||
for ch, t in times.items():
|
||||
assert abs(getattr(pv, f"{ch}_time_of_peak") - t) <= 0.0005 + 1e-9, (ch, getattr(pv, f"{ch}_time_of_peak"))
|
||||
assert abs(pv.pvs_time - pvs_time) <= 0.0005 + 1e-9
|
||||
for got, want in zip((pv.tran_peak_accel_g, pv.vert_peak_accel_g, pv.long_peak_accel_g), accel):
|
||||
assert abs(got - want) <= 0.0005 + 1e-9, (got, want)
|
||||
|
||||
|
||||
def test_a_histogram_has_no_waveform_peak_detail():
|
||||
pv = read_blastware_file(_FIX / "decode-checker-10-29-26/T004JTRF.ME0H").peak_values
|
||||
assert (pv.tran_time_of_peak, pv.pvs_time, pv.tran_peak_accel_g) == (None, None, None)
|
||||
@@ -83,9 +83,12 @@ def test_a_waveform_read_under_another_name_keeps_its_time(tmp_path):
|
||||
datetime.datetime(2026, 10, 26, 14, 23, 42)
|
||||
|
||||
|
||||
def test_a_histogram_keeps_the_binarys_window_start():
|
||||
assert blastware_filename_time(HISTOGRAM.name) != datetime.datetime(2026, 5, 10, 19, 4, 50)
|
||||
assert _dt(read_blastware_file(HISTOGRAM).timestamp) == datetime.datetime(2026, 5, 10, 19, 4, 50)
|
||||
def test_a_histogram_now_agrees_with_its_filename():
|
||||
# #51: the start comes from the histogram's own event record, which is
|
||||
# Blastware's -- and so the filename's. The footer's window start (19:04:50)
|
||||
# was a second early.
|
||||
assert blastware_filename_time(HISTOGRAM.name) == datetime.datetime(2026, 5, 10, 19, 4, 51)
|
||||
assert _dt(read_blastware_file(HISTOGRAM).timestamp) == datetime.datetime(2026, 5, 10, 19, 4, 51)
|
||||
|
||||
|
||||
def test_an_import_no_longer_lands_a_waveform_on_its_histogram_twins_row(tmp_path):
|
||||
|
||||
+137
-3
@@ -39,7 +39,9 @@ def test_event_type_comes_from_the_bytes():
|
||||
|
||||
def test_report_fields_stay_blank():
|
||||
s = sfm_side((FIX / "T1905KDW.5F0W").read_bytes())
|
||||
for tag in ("TranZCFreq", "TranPeakAcceleration", "BatteryLevel", "Calibration", "TranTestResults"):
|
||||
# (BatteryLevel and Calibration are read since 2026-11-03, peak acceleration
|
||||
# since 2026-11-04: test_the_setup_fields_match_blastware, test_waveform_peak_detail_*)
|
||||
for tag in ("TranZCFreq", "TranPeakDisplacement", "TranTestResults"):
|
||||
assert s.values.get(tag) is None
|
||||
|
||||
|
||||
@@ -66,7 +68,7 @@ def test_full_waveform_row_verdicts():
|
||||
"notes", "samples.Tran", "samples.Vert", "samples.Long"):
|
||||
assert res[f].verdict == "match", (f, res[f])
|
||||
assert res["TranZCFreq"].verdict in ("sfm_blank", "no_reference")
|
||||
assert res["BatteryLevel"].verdict == "sfm_blank"
|
||||
assert res["BatteryLevel"].verdict == "match" # 6.72 V, printed "6.7 Volts"
|
||||
assert "FileName" not in res
|
||||
|
||||
|
||||
@@ -95,7 +97,7 @@ def test_zc_frequency_na_and_above_range():
|
||||
def test_mic_units_pick_the_conversion():
|
||||
res = _results("T004JTRF.ME0H") # psi(L)
|
||||
assert res["intervals.MicL Peak dB(L)"].verdict in ("match", "mismatch")
|
||||
assert res["intervals.Tran Freq Hz"].verdict == "sfm_blank"
|
||||
assert res["intervals.Tran Freq Hz"].verdict == "match" # read since 2026-11-03
|
||||
fields = set(_results("R352HFZ7.530H")) # no mic
|
||||
assert not any(f.startswith(("samples.MicL", "intervals.MicL")) for f in fields)
|
||||
|
||||
@@ -221,3 +223,135 @@ def test_blastware_counting_the_monitoring_time_is_accepted():
|
||||
|
||||
def test_the_count_carveout_needs_blastwares_own_table_to_agree_with_sfm():
|
||||
assert _count_case(30, drop_rows=1).verdict == "mismatch"
|
||||
|
||||
|
||||
_GROUP_A = ("SerialNumber", "Version", "Calibration", "BatteryLevel", "Trigger",
|
||||
"GeoTriggerLevel", "MicTriggerLevel", "RecordStopMode", "Microphone", "Units")
|
||||
|
||||
|
||||
@pytest.mark.parametrize("stem,printed", [
|
||||
("T189HUD6.QE0W", set(_GROUP_A)),
|
||||
("T438L713.RY0W", set(_GROUP_A)), # 130.8 dB(L): 0.01 psi at 6895 Pa/psi
|
||||
("K558L4KY.440H", {"SerialNumber", "Version", "Calibration", "BatteryLevel",
|
||||
"Microphone", "Units"}), # histogram; battery 6.25 -> "6.3"
|
||||
])
|
||||
def test_the_setup_fields_match_blastware(stem, printed):
|
||||
sf = FIX.parent / "setup-fields-11-03-26"
|
||||
res = {r.field: r for r in compare(sfm_side((sf / stem).read_bytes()),
|
||||
parse_xml_report_file(sf / (stem.replace(".", "_", 1) + "_XML.XML")),
|
||||
CARVEOUTS)}
|
||||
assert printed <= set(res)
|
||||
for f in printed:
|
||||
assert res[f].verdict == "match", (f, res[f])
|
||||
|
||||
|
||||
def test_a_manual_trigger_matches():
|
||||
res = _results("T1905KDW.5F0W", CARVEOUTS)
|
||||
assert res["Trigger"].verdict == "match"
|
||||
|
||||
|
||||
def _units_case(sfm_units):
|
||||
sf = FIX.parent / "setup-fields-11-03-26"
|
||||
ref = parse_xml_report_file(sf / "T189HUD6_QE0W_XML.XML")
|
||||
ref.scalars["Units"] = "in/s and psi(L)"
|
||||
side = sfm_side((sf / "T189HUD6.QE0W").read_bytes())
|
||||
if sfm_units is not None:
|
||||
side.values["Units"] = sfm_units
|
||||
return {r.field: r for r in compare(side, ref, CARVEOUTS)}["Units"]
|
||||
|
||||
|
||||
def test_dB_or_psi_is_blastwares_display_preference():
|
||||
# Blastware writes its report in its PC's current preference; DL2's reports
|
||||
# switch fleet-wide in 61 clean runs by write time, and no byte in the file
|
||||
# tells them apart.
|
||||
r = _units_case(None)
|
||||
assert (r.verdict, r.carveout) == ("accepted", "units-is-a-display-preference")
|
||||
|
||||
|
||||
def test_the_units_carveout_still_needs_the_mic():
|
||||
assert _units_case("in/s").verdict == "mismatch"
|
||||
|
||||
|
||||
def test_a_mic_trigger_level_is_read_in_the_unit_it_is_printed_in():
|
||||
# K441LA17.IN0W: Units "in/s and psi(L)", yet MicTriggerLevel "125.0 dB(L)".
|
||||
# The printed value states its own unit; that is the one to compare in.
|
||||
sf = FIX.parent / "setup-fields-11-03-26"
|
||||
ref = parse_xml_report_file(sf / "T189HUD6_QE0W_XML.XML") # 128.0 dB(L)
|
||||
ref.event_units = "in/s and psi(L)"
|
||||
res = {r.field: r for r in compare(sfm_side((sf / "T189HUD6.QE0W").read_bytes()), ref, CARVEOUTS)}
|
||||
assert res["MicTriggerLevel"].verdict == "match", res["MicTriggerLevel"]
|
||||
|
||||
|
||||
@pytest.mark.parametrize("path", [FIX / "T004JTRF.ME0H",
|
||||
FIX.parent / "histogram-intervals-11-03-26" / "T190LD42.T00H"])
|
||||
def test_histogram_interval_detail_matches_blastware(path):
|
||||
ref = parse_xml_report_file(path.with_name(path.name.replace(".", "_", 1) + "_XML.XML"))
|
||||
res = {r.field: r for r in compare(sfm_side(path.read_bytes()), ref, CARVEOUTS)}
|
||||
for f in ("IntervalSize", "HistogramStopDate", "HistogramStopTime", "intervals.Tran Freq Hz",
|
||||
"intervals.Vert Freq Hz", "intervals.Long Freq Hz", "intervals.MicL Freq Hz",
|
||||
"intervals.Geo PVS in/s"):
|
||||
assert res[f].verdict == "match", (f, res[f])
|
||||
|
||||
|
||||
@pytest.mark.parametrize("halfp,sr,want", [
|
||||
(0, 1024, "N/A"), (5, 1024, ">100"), (5, 2048, ">200"), (1024, 1024, "<1.0"),
|
||||
])
|
||||
def test_blastwares_interval_frequency_words(halfp, sr, want):
|
||||
# N/A for a half-period of 0, ">100" / ">200" at 5 samples or fewer, "<1.0"
|
||||
# below 1 Hz -- on ~3.1 M DL2 cells, 2026-11-03.
|
||||
from minimateplus.decode_check import interval_frequency
|
||||
assert interval_frequency(halfp, sr) == want
|
||||
|
||||
|
||||
def _pvs_oorange(unclamp=False):
|
||||
hb = FIX.parent / "histogram-intervals-11-03-26"
|
||||
ref = parse_xml_report_file(hb / "T190LD5Q_LD0H_XML.XML") # Geo PVS OORANGE, Vert OORANGE
|
||||
if unclamp:
|
||||
cols = ref.interval_columns
|
||||
t, row = ref.intervals[0]
|
||||
row = list(row)
|
||||
row[cols.index("Vert Peak in/s")] = "0.500"
|
||||
ref.intervals[0] = (t, row)
|
||||
res = {r.field: r for r in compare(sfm_side((hb / "T190LD5Q.LD0H").read_bytes()), ref, CARVEOUTS)}
|
||||
return res["intervals.Geo PVS in/s"]
|
||||
|
||||
|
||||
def test_an_oorange_interval_vector_sum_is_saturation():
|
||||
# Blastware prints OORANGE for an interval's vector sum above the range when
|
||||
# it clamped a channel in that interval: 17 / 17 DL2 cells, SFM's sum
|
||||
# 10.01 .. 17.33 (= sqrt 3 x 10.005).
|
||||
r = _pvs_oorange()
|
||||
assert (r.verdict, r.carveout) == ("accepted", "saturation")
|
||||
|
||||
|
||||
def test_an_oorange_vector_sum_needs_a_clamped_channel_in_that_interval():
|
||||
assert _pvs_oorange(unclamp=True).verdict == "mismatch"
|
||||
|
||||
|
||||
_PEAK_TIMES = ("TranPeakDate", "TranPeakTime", "VertPeakDate", "VertPeakTime", "LongPeakDate",
|
||||
"LongPeakTime", "PeakVectorSumDate", "PeakVectorSumTime", "MicLDate", "MicLTime")
|
||||
|
||||
|
||||
@pytest.mark.parametrize("path", [FIX / "T004JTRF.ME0H", # 1 interval
|
||||
FIX.parent / "footer-11-03-26" / "T003LCYV.JD0H", # 145
|
||||
FIX.parent / "histogram-decode-11-02-26" / "K440HA3C.JM0H"]) # 8 x 5 s
|
||||
def test_histogram_times_match_blastware(path):
|
||||
# #51: an interval's printed time is its end -- start + (n + 1) x interval,
|
||||
# capped at the stop -- and each peak's date and time are its interval's:
|
||||
# 2,308,524 / 2,308,524 rows and 2,000 / 2,000 peaks each on a DL2 sample.
|
||||
ref = parse_xml_report_file(path.with_name(path.name.replace(".", "_", 1) + "_XML.XML"))
|
||||
res = {r.field: r for r in compare(sfm_side(path.read_bytes()), ref, CARVEOUTS)}
|
||||
for f in (("HistogramStartDate", "HistogramStartTime", "HistogramStopTime", "intervals.Time")
|
||||
+ tuple(t for t in _PEAK_TIMES if t in ref.scalars)):
|
||||
assert res[f].verdict == "match", (f, res[f])
|
||||
|
||||
|
||||
@pytest.mark.parametrize("path", [FIX / "R352HIUI.F40W",
|
||||
FIX.parent / "setup-fields-11-03-26" / "T189HUD6.QE0W"])
|
||||
def test_waveform_peak_detail_matches_blastware(path):
|
||||
ref = parse_xml_report_file(path.with_name(path.name.replace(".", "_", 1) + "_XML.XML"))
|
||||
res = {r.field: r for r in compare(sfm_side(path.read_bytes()), ref, CARVEOUTS)}
|
||||
for f in ("TranTimeofPeak", "VertTimeofPeak", "LongTimeofPeak", "MicLTimeofPeak",
|
||||
"PeakVectorSumTimeSum", "TranPeakAcceleration", "VertPeakAcceleration",
|
||||
"LongPeakAcceleration"):
|
||||
assert res[f].verdict == "match", (f, res[f])
|
||||
@@ -11,7 +11,7 @@ sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
|
||||
import minimateplus.protocol as mmp_proto # noqa: E402
|
||||
from device_access_fakes import FakeMiniMateClient # noqa: E402
|
||||
from sfm.device_access.errors import ( # noqa: E402
|
||||
ConnectFailed, MalformedReply, NoAnswer, WrongUnit,
|
||||
ConnectFailed, MalformedReply, NoAnswer, UnitStateUnknown, WrongUnit,
|
||||
)
|
||||
from sfm.device_access.models import UnitAddress # noqa: E402
|
||||
from sfm.device_access.s3 import Series3Adapter # noqa: E402
|
||||
@@ -51,20 +51,20 @@ def test_status_maps_monitor_status():
|
||||
assert fake.calls == ["poll", "get_monitor_status"]
|
||||
|
||||
|
||||
def test_settings_maps_the_compliance_config():
|
||||
s = adapter(FakeMiniMateClient()).settings(TCP, "BE18193")
|
||||
assert s.record_mode == "Continuous"
|
||||
assert (s.sample_rate, s.record_time_s, s.histogram_interval_s) == (1024, 3.0, 300)
|
||||
assert s.geo_trigger_ips == 0.5
|
||||
assert s.setup_name == "BRIDGE-A"
|
||||
assert s.notes == {"Project": "Bridge job", "Client": "Acme", "User Name": "BH", "Seis Loc": "Loc 1"}
|
||||
assert s.detail["record_mode_code"] == 0x01
|
||||
def test_settings_reads_the_logical_block():
|
||||
# Phase 5: the settings come from the 1A read assembled into its 2,090 bytes and
|
||||
# decoded by micromate.setup_fields (tests/test_device_access_s3_settings.py has
|
||||
# the rest); the fake's block is BE9441's of 2026-10-26.
|
||||
fake = FakeMiniMateClient()
|
||||
s = adapter(fake).settings(TCP, "BE18193")
|
||||
assert (s.record_mode, s.sample_rate, s.setup_name) == ("Histogram", 4096, "Standard Recording Setup.set")
|
||||
assert fake.calls.index("connect") < fake.calls.index("read_compliance_content")
|
||||
|
||||
|
||||
def test_settings_without_a_compliance_read_is_a_malformed_reply_and_not_retried():
|
||||
def test_settings_of_a_monitoring_unit_is_refused_and_not_retried():
|
||||
# One fake only: a retry would ask the factory for a second and fail.
|
||||
with pytest.raises(MalformedReply, match="settings"):
|
||||
adapter(FakeMiniMateClient(compliance=None)).settings(TCP, "BE18193")
|
||||
with pytest.raises(UnitStateUnknown, match="settings"):
|
||||
adapter(FakeMiniMateClient(monitoring_settings=True)).settings(TCP, "BE18193")
|
||||
|
||||
|
||||
def test_a_cold_unit_over_tcp_gets_one_retry():
|
||||
|
||||
@@ -0,0 +1,241 @@
|
||||
"""Changing a MiniMate's settings by serial (phase 5): preview, one audited send,
|
||||
read back. The settings block is the 1A read assembled into its 2,090 logical
|
||||
bytes; the write is push_config_raw's Blastware sequence (68 73 | 71 x n 72 |
|
||||
82 83 | 69 74 72) with the event index, trigger and waveform blocks sent back as
|
||||
read. Fixture blocks: BE9441, 2026-10-26."""
|
||||
from __future__ import annotations
|
||||
|
||||
import os
|
||||
import sys
|
||||
|
||||
import pytest
|
||||
|
||||
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
|
||||
|
||||
import minimateplus.protocol as mp # noqa: E402
|
||||
from device_access_fakes import FakeMiniMateClient, s3_settings_blocks # noqa: E402
|
||||
from micromate.setup_fields import encode_setup, field_values # noqa: E402
|
||||
from minimateplus.client import MiniMateClient # noqa: E402
|
||||
from minimateplus.protocol import ImageRefused # noqa: E402
|
||||
from sfm.device_access.errors import ( # noqa: E402
|
||||
BadRequest, DeviceError, SettingsChanged, UnitStateUnknown,
|
||||
)
|
||||
from sfm.device_access.models import UnitAddress # noqa: E402
|
||||
from sfm.device_access.s3 import Series3Adapter # noqa: E402
|
||||
|
||||
TCP = UnitAddress(host="10.0.0.6", tcp_port=12345, port=None, baud=None)
|
||||
BW_ORDER = ["0x68", "0x73", "0x71", "0x72", "0x82", "0x83", "0x69", "0x74", "0x72"]
|
||||
|
||||
|
||||
class Audit:
|
||||
def __init__(self):
|
||||
self.rows = {}
|
||||
|
||||
def begin(self, **f):
|
||||
cid = f"c{len(self.rows) + 1}"
|
||||
self.rows[cid] = dict(f, outcome="pending")
|
||||
return cid
|
||||
|
||||
def finish(self, cid, **f):
|
||||
self.rows[cid].update(f)
|
||||
|
||||
|
||||
def adapter(fake):
|
||||
return Series3Adapter(client_factory=lambda address, **kw: fake)
|
||||
|
||||
|
||||
def change(fake, changes, *, revision=None, dry_run=False, audit=None):
|
||||
return adapter(fake).change_settings(
|
||||
TCP, "BE18193", changes=changes, revision=revision, dry_run=dry_run,
|
||||
audit=audit if audit is not None else Audit(), caller="test", sleep=lambda s: None,
|
||||
verify_timeout_s=2.0, verify_interval_s=1.0)
|
||||
|
||||
|
||||
def live(fake, changes, audit=None):
|
||||
rev = change(fake, changes, dry_run=True).plan["revision"]
|
||||
return change(fake, changes, revision=rev, audit=audit)
|
||||
|
||||
|
||||
def test_s3_settings_read_uses_the_codec():
|
||||
s = adapter(FakeMiniMateClient()).settings(TCP, "BE18193")
|
||||
assert (s.record_mode, s.sample_rate, s.histogram_interval_s) == ("Histogram", 4096, 2)
|
||||
assert (s.record_time_s, s.geo_trigger_ips) == (20.0, 0.04)
|
||||
assert s.notes["Project"] == "TestUnit-Minimate" and s.notes["Client"] == "Terra-Mechanics"
|
||||
assert s.detail["record_mode_code"] == 0x03 and s.detail["geo_range"] == "normal"
|
||||
fields = {d["field"]: d for d in s.detail["editable"]}
|
||||
assert fields["geo_range"]["value"] == "normal" and fields["note_1"]["label"] == "Project"
|
||||
|
||||
|
||||
def test_s3_settings_read_of_a_monitoring_unit_says_why():
|
||||
with pytest.raises(UnitStateUnknown, match="stop monitoring first"):
|
||||
adapter(FakeMiniMateClient(monitoring_settings=True)).settings(TCP, "BE18193")
|
||||
|
||||
|
||||
def test_s3_dry_run_previews_and_sends_nothing():
|
||||
fake = FakeMiniMateClient()
|
||||
r = change(fake, {"geo_trigger_ips": 0.05}, dry_run=True)
|
||||
assert r.outcome == "dry_run" and fake.writes == []
|
||||
assert r.plan["fields"] == {"geo_trigger_ips": {"label": "Geophone trigger", "old": 0.04, "new": 0.05}}
|
||||
assert [s["sub"] for s in r.plan["steps"]] == BW_ORDER
|
||||
assert any("00 00" in w for w in r.plan["warnings"]) and r.plan["blocked"] == []
|
||||
assert len(r.plan["revision"]) == 16
|
||||
|
||||
|
||||
def test_s3_trigger_change_sends_the_units_own_blocks():
|
||||
fake = FakeMiniMateClient()
|
||||
blocks = s3_settings_blocks()
|
||||
live(fake, {"geo_trigger_ips": 0.05})
|
||||
event_index, compliance, trigger, waveform = fake.pushed
|
||||
assert (event_index, trigger, waveform) == (blocks["event_index"], blocks["trigger"], blocks["waveform"])
|
||||
assert compliance == encode_setup(blocks["compliance"], 3, {"geo_trigger_ips": 0.05})
|
||||
|
||||
|
||||
def test_s3_change_verifies_by_read_back():
|
||||
fake = FakeMiniMateClient()
|
||||
r = live(fake, {"geo_trigger_ips": 0.05, "note_4": "Loc 2 - north wall"})
|
||||
assert (r.outcome, r.verified, r.state_after) == ("sent", "ok", "as asked")
|
||||
rows = r.detail["snapshot"]["fields"]
|
||||
assert rows["geo_trigger_ips"] == {"label": "Geophone trigger", "old": 0.04, "new": 0.05, "now": 0.05}
|
||||
assert rows["note_4"]["now"] == "Loc 2 - north wall"
|
||||
assert field_values(fake.settings_blocks["compliance"], 3)["geo_trigger_ips"] == 0.05
|
||||
|
||||
|
||||
def test_s3_stale_revision_sends_nothing():
|
||||
fake = FakeMiniMateClient()
|
||||
rev = change(fake, {"geo_trigger_ips": 0.05}, dry_run=True).plan["revision"]
|
||||
fake.settings_blocks["compliance"] = encode_setup(fake.settings_blocks["compliance"], 3, {"job_number": 9})
|
||||
audit = Audit()
|
||||
with pytest.raises(SettingsChanged):
|
||||
change(fake, {"geo_trigger_ips": 0.05}, revision=rev, audit=audit)
|
||||
assert fake.writes == [] and audit.rows == {}
|
||||
|
||||
|
||||
@pytest.mark.parametrize("dry_run", [True, False])
|
||||
def test_s3_monitoring_is_refused(dry_run):
|
||||
fake = FakeMiniMateClient(monitoring_settings=True)
|
||||
with pytest.raises(UnitStateUnknown) as e:
|
||||
change(fake, {"geo_trigger_ips": 0.05}, revision="x", dry_run=dry_run)
|
||||
assert "stop monitoring first" in str(e.value) and "nothing sent" in str(e.value)
|
||||
assert fake.writes == []
|
||||
|
||||
|
||||
def test_s3_a_value_the_unit_does_not_allow_is_a_bad_request():
|
||||
with pytest.raises(BadRequest):
|
||||
change(FakeMiniMateClient(), {"record_time_s": 30.0}, dry_run=True) # 4096 sps: 26 s at most
|
||||
|
||||
|
||||
def test_s3_a_refused_image_is_audited_as_nothing_sent():
|
||||
audit = Audit()
|
||||
fake = FakeMiniMateClient(write_error=ImageRefused("write SUB 0x71: not a whole block"))
|
||||
rev = change(fake, {"geo_trigger_ips": 0.05}, dry_run=True).plan["revision"]
|
||||
with pytest.raises(DeviceError):
|
||||
change(fake, {"geo_trigger_ips": 0.05}, revision=rev, audit=audit)
|
||||
((_, row),) = audit.rows.items()
|
||||
assert (row["outcome"], row["sent"]) == ("failed", 0)
|
||||
assert row["error"].startswith("refused before sending")
|
||||
|
||||
|
||||
class _Recorder:
|
||||
def __init__(self):
|
||||
self.sent = []
|
||||
|
||||
def write(self, data):
|
||||
self.sent.append(bytes(data))
|
||||
|
||||
def read(self, n):
|
||||
return b""
|
||||
|
||||
|
||||
def test_push_config_raw_precheck_raises_image_refused():
|
||||
t = _Recorder()
|
||||
c = MiniMateClient("unused")
|
||||
c._proto = mp.MiniMateProtocol(t, recv_timeout=0.2)
|
||||
b = s3_settings_blocks()
|
||||
with pytest.raises(ImageRefused):
|
||||
c.push_config_raw(b["event_index"], b["compliance"][:2089], b["trigger"], b["waveform"])
|
||||
assert t.sent == []
|
||||
|
||||
|
||||
# Final review #1: the revision covers the changes previewed, not only the unit.
|
||||
def test_s3_a_revision_covers_the_changes_previewed():
|
||||
fake = FakeMiniMateClient()
|
||||
rev = change(fake, {"job_number": 7}, dry_run=True).plan["revision"]
|
||||
with pytest.raises(SettingsChanged):
|
||||
change(fake, {"geo_trigger_ips": 0.05}, revision=rev)
|
||||
assert fake.writes == []
|
||||
|
||||
|
||||
# Ruling: the trigger block's byte 5 "differs by unit and session" (#46); the three
|
||||
# echoed blocks are re-read at send and sent as read, so they are not in the revision.
|
||||
def test_s3_an_echoed_block_moving_does_not_stale_the_preview():
|
||||
fake = FakeMiniMateClient()
|
||||
rev = change(fake, {"geo_trigger_ips": 0.05}, dry_run=True).plan["revision"]
|
||||
trig = bytearray(fake.settings_blocks["trigger"])
|
||||
trig[5] = 0x03
|
||||
fake.settings_blocks["trigger"] = bytes(trig)
|
||||
assert change(fake, {"geo_trigger_ips": 0.05}, revision=rev).verified == "ok"
|
||||
assert fake.pushed[2] == bytes(trig) # sent as read at send time
|
||||
|
||||
|
||||
# Final review #4 (spec): the refusal says a stop makes the unit call in.
|
||||
def test_s3_monitoring_refusal_says_a_stop_calls_in():
|
||||
with pytest.raises(UnitStateUnknown) as e:
|
||||
change(FakeMiniMateClient(monitoring_settings=True), {"geo_trigger_ips": 0.05}, dry_run=True)
|
||||
assert "call in" in str(e.value) and "call-home" in str(e.value)
|
||||
|
||||
|
||||
# Final review #3: the blocks are logical bytes; a block holding a literal
|
||||
# 10 02 / 10 03 / 10 04 (job number 4098 = 0x1002) must be written intact, and a
|
||||
# block the write would refuse must show in the preview, not only at Send.
|
||||
def test_s3_a_bad_echoed_block_is_blocked_in_the_preview():
|
||||
fake = FakeMiniMateClient()
|
||||
fake.settings_blocks["event_index"] = fake.settings_blocks["event_index"][:-1]
|
||||
r = change(fake, {"geo_trigger_ips": 0.05}, dry_run=True)
|
||||
assert r.plan["blocked"] and r.plan["steps"] == []
|
||||
from sfm.device_access.errors import ChangeRefused
|
||||
with pytest.raises(ChangeRefused):
|
||||
change(fake, {"geo_trigger_ips": 0.05}, revision=r.plan["revision"])
|
||||
assert fake.writes == []
|
||||
|
||||
|
||||
def _acking():
|
||||
from minimateplus.framing import build_bw_write_frame # noqa: F401 (frames are parsed below)
|
||||
from test_minimate_write_frames import _payload
|
||||
|
||||
class Acks:
|
||||
def __init__(self):
|
||||
self.sent, self._buf = [], b""
|
||||
|
||||
def write(self, data):
|
||||
data = bytes(data)
|
||||
self.sent.append(data)
|
||||
sub = _payload(data)[2]
|
||||
body = bytes([0x00, 0x10, 0xFF - sub, 0x00, 0x00]) + bytes(11)
|
||||
body += bytes([sum(body) & 0xFF])
|
||||
self._buf += b"\x10\x02" + body.replace(b"\x10", b"\x10\x10") + b"\x03"
|
||||
|
||||
def read(self, n):
|
||||
out, self._buf = self._buf[:n], self._buf[n:]
|
||||
return out
|
||||
return Acks()
|
||||
|
||||
|
||||
def test_push_config_raw_writes_a_logical_block_with_a_literal_escape_byte_intact():
|
||||
from test_minimate_write_frames import _payload
|
||||
t = _acking()
|
||||
c = MiniMateClient("unused")
|
||||
c._proto = mp.MiniMateProtocol(t, recv_timeout=0.5)
|
||||
b = s3_settings_blocks()
|
||||
block = encode_setup(b["compliance"], 3, {"job_number": 4098}) # [40:42] = 10 02
|
||||
assert block[40:42] == b"\x10\x02"
|
||||
c.push_config_raw(b["event_index"], block, b["trigger"], b["waveform"])
|
||||
sent = b"".join(_payload(f)[16:] for f in t.sent if _payload(f)[2] == 0x71)
|
||||
assert sent == block + b"\x00\x00"
|
||||
|
||||
|
||||
# Bench 2026-11-04 (BE9441): a write sent while the unit's setup menu was open was
|
||||
# acknowledged and read back -- and then lost when the operator pressed Cancel or
|
||||
# Save: the menu writes its own copy of the WHOLE block back. The preview says so.
|
||||
def test_the_preview_warns_that_an_open_setup_menu_loses_the_change():
|
||||
r = change(FakeMiniMateClient(), {"geo_trigger_ips": 0.05}, dry_run=True)
|
||||
assert any("setup menu" in w and "lost" in w for w in r.plan["warnings"])
|
||||
@@ -0,0 +1,192 @@
|
||||
"""Changing a Micromate's settings by serial (phase 5): preview, one audited send,
|
||||
read back. The push is micromate.writes.plan_setup_push (THOR's frames) under
|
||||
the active setup's own name; the unit's schedule is read first, because a
|
||||
scheduled start loads the setup it names and would undo a change to another."""
|
||||
from __future__ import annotations
|
||||
|
||||
import os
|
||||
import sys
|
||||
|
||||
import pytest
|
||||
|
||||
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
|
||||
|
||||
import micromate.protocol as mm_proto # noqa: E402
|
||||
from device_access_fakes import FakeMicromateClient, schedule_record # noqa: E402
|
||||
from micromate.opcodes import ENABLEABLE_WRITES # noqa: E402
|
||||
from micromate.setup_fields import field_values # noqa: E402
|
||||
from sfm.device_access.errors import ( # noqa: E402
|
||||
BadRequest, ChangeRefused, SettingsChanged, UnitStateUnknown,
|
||||
)
|
||||
from sfm.device_access.models import UnitAddress # noqa: E402
|
||||
from sfm.device_access.s4 import s4_change_settings, s4_settings # noqa: E402
|
||||
|
||||
ADDR = UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None)
|
||||
PUSH_SUBS = [0xDA, 0x68, 0x73, 0x82, 0x83, 0x71, 0x72]
|
||||
|
||||
|
||||
class Audit:
|
||||
def __init__(self):
|
||||
self.rows = {}
|
||||
|
||||
def begin(self, **f):
|
||||
cid = f"c{len(self.rows) + 1}"
|
||||
self.rows[cid] = dict(f, outcome="pending")
|
||||
return cid
|
||||
|
||||
def finish(self, cid, **f):
|
||||
self.rows[cid].update(f)
|
||||
|
||||
|
||||
def change(fake, changes, *, revision=None, dry_run=False, audit=None):
|
||||
return s4_change_settings(fake, "UM20147", changes=changes, revision=revision, dry_run=dry_run,
|
||||
audit=audit if audit is not None else Audit(), address=ADDR,
|
||||
caller="test", sleep=lambda s: None,
|
||||
verify_timeout_s=2.0, verify_interval_s=1.0)
|
||||
|
||||
|
||||
def live(fake, changes, audit=None):
|
||||
rev = change(fake, changes, dry_run=True).plan["revision"]
|
||||
return change(fake, changes, revision=rev, audit=audit)
|
||||
|
||||
|
||||
def test_setup_push_subs_are_now_enableable():
|
||||
assert set(PUSH_SUBS) <= ENABLEABLE_WRITES
|
||||
|
||||
|
||||
def test_s4_settings_read_describes_the_editable_fields():
|
||||
st = s4_settings(FakeMicromateClient(), "UM20147")
|
||||
fields = {d["field"]: d for d in st.detail["editable"]}
|
||||
assert fields["geo_trigger_ips"]["value"] == 0.5 and "geo_range" not in fields
|
||||
|
||||
|
||||
def test_s4_dry_run_previews_old_to_new_and_sends_nothing():
|
||||
fake = FakeMicromateClient()
|
||||
r = change(fake, {"geo_trigger_ips": 0.3}, dry_run=True)
|
||||
assert r.outcome == "dry_run"
|
||||
assert r.plan["fields"] == {"geo_trigger_ips": {"label": "Geophone trigger", "old": 0.5, "new": 0.3}}
|
||||
assert len(r.plan["revision"]) == 16 and r.plan["blocked"] == []
|
||||
assert [s["sub"] for s in r.plan["steps"]] == [f"0x{s:02X}" for s in PUSH_SUBS]
|
||||
assert any("edit buffer" in w for w in r.plan["warnings"])
|
||||
assert fake.executed == []
|
||||
|
||||
|
||||
def test_s4_trigger_change_sends_the_push_and_verifies():
|
||||
fake = FakeMicromateClient()
|
||||
r = live(fake, {"geo_trigger_ips": 0.3})
|
||||
assert (r.outcome, r.verified, r.state_after) == ("sent", "ok", "as asked")
|
||||
assert [st.sub for st in fake.executed[0].steps] == PUSH_SUBS
|
||||
assert field_values(fake.setup, 4)["geo_trigger_ips"] == 0.3
|
||||
assert r.detail["snapshot"]["fields"]["geo_trigger_ips"] == {
|
||||
"label": "Geophone trigger", "old": 0.5, "new": 0.3, "now": 0.3}
|
||||
name_step = fake.executed[0].steps[0]
|
||||
assert name_step.data.rstrip(b"\x00") == b"TEST1.mmb" # the active setup's own name
|
||||
|
||||
|
||||
def test_s4_stale_revision_sends_nothing():
|
||||
fake = FakeMicromateClient()
|
||||
rev = change(fake, {"geo_trigger_ips": 0.3}, dry_run=True).plan["revision"]
|
||||
fake.setup = FakeMicromateClient(setup=None).setup[:40] + b"\x00\x07" + fake.setup[42:] # job number moved
|
||||
audit = Audit()
|
||||
with pytest.raises(SettingsChanged):
|
||||
change(fake, {"geo_trigger_ips": 0.3}, revision=rev, audit=audit)
|
||||
assert fake.executed == [] and audit.rows == {}
|
||||
|
||||
|
||||
def test_s4_already_as_asked_is_skipped():
|
||||
fake = FakeMicromateClient()
|
||||
r = live(fake, {"geo_trigger_ips": 0.5})
|
||||
assert r.outcome == "skipped" and fake.executed == []
|
||||
|
||||
|
||||
@pytest.mark.parametrize("dry_run", [True, False])
|
||||
def test_s4_monitoring_is_refused(dry_run):
|
||||
fake = FakeMicromateClient(run_states=[0x02])
|
||||
with pytest.raises(UnitStateUnknown) as e:
|
||||
change(fake, {"geo_trigger_ips": 0.3}, revision="x", dry_run=dry_run)
|
||||
assert "stop it first" in str(e.value) and "nothing sent" in str(e.value)
|
||||
assert fake.executed == []
|
||||
|
||||
|
||||
def test_s4_a_value_the_unit_does_not_allow_is_a_bad_request():
|
||||
with pytest.raises(BadRequest):
|
||||
change(FakeMicromateClient(), {"geo_trigger_ips": 12.0}, dry_run=True)
|
||||
|
||||
|
||||
def test_s4_factory_setup_is_refused_live_and_shown_in_preview():
|
||||
fake = FakeMicromateClient(active_name="factory.MMB")
|
||||
r = change(fake, {"geo_trigger_ips": 0.3}, dry_run=True)
|
||||
assert any("factory setup" in b for b in r.plan["blocked"]) and r.plan["steps"] == []
|
||||
with pytest.raises(ChangeRefused):
|
||||
change(fake, {"geo_trigger_ips": 0.3}, revision=r.plan["revision"])
|
||||
assert fake.executed == []
|
||||
|
||||
|
||||
def test_s4_schedule_conflict_blocks():
|
||||
fake = FakeMicromateClient(schedule_body=schedule_record(14, 0x02, "other.mmb") + bytes(264))
|
||||
r = change(fake, {"geo_trigger_ips": 0.3}, dry_run=True)
|
||||
assert any("other.mmb" in b and "07:00" in b for b in r.plan["blocked"])
|
||||
with pytest.raises(ChangeRefused) as e:
|
||||
change(fake, {"geo_trigger_ips": 0.3}, revision=r.plan["revision"])
|
||||
assert "nothing sent" in str(e.value) and fake.executed == []
|
||||
|
||||
|
||||
def test_s4_schedule_on_the_active_setup_warns_only():
|
||||
fake = FakeMicromateClient(schedule_body=schedule_record(14, 0x02, "test1.MMB")
|
||||
+ schedule_record(37, 0x04) + bytes(4))
|
||||
r = change(fake, {"geo_trigger_ips": 0.3}, dry_run=True)
|
||||
assert r.plan["blocked"] == [] and any("survives" in w and "07:00" in w for w in r.plan["warnings"])
|
||||
assert live(fake, {"geo_trigger_ips": 0.3}).verified == "ok"
|
||||
|
||||
|
||||
def test_an_unreadable_schedule_refuses():
|
||||
fake = FakeMicromateClient(schedule_error=mm_proto.ProtocolError("no reply to 0x94"))
|
||||
r = change(fake, {"geo_trigger_ips": 0.3}, dry_run=True)
|
||||
assert any("could not read this unit's schedule" in b for b in r.plan["blocked"])
|
||||
with pytest.raises(ChangeRefused):
|
||||
change(fake, {"geo_trigger_ips": 0.3}, revision=r.plan["revision"])
|
||||
assert fake.executed == []
|
||||
|
||||
|
||||
def test_no_schedule_records_is_no_conflict():
|
||||
r = live(FakeMicromateClient(), {"geo_trigger_ips": 0.3})
|
||||
assert r.verified == "ok"
|
||||
|
||||
|
||||
def test_s4_a_lost_ack_records_what_the_unit_holds():
|
||||
fake = FakeMicromateClient(execute_error=mm_proto.TimeoutError("lost"))
|
||||
r = live(fake, {"geo_trigger_ips": 0.3})
|
||||
assert (r.outcome, r.sent) == ("failed", True)
|
||||
snap = r.detail["snapshot"]
|
||||
assert snap["fields"]["geo_trigger_ips"]["now"] == 0.5 and snap["changed_offsets"] == []
|
||||
|
||||
|
||||
def test_s4_unseen_block_size_is_blocked():
|
||||
fake = FakeMicromateClient()
|
||||
fake.prefs = fake.prefs + b"\x00"
|
||||
r = change(fake, {"geo_trigger_ips": 0.3}, dry_run=True)
|
||||
assert any("has not seen a block like it" in b for b in r.plan["blocked"])
|
||||
with pytest.raises(ChangeRefused):
|
||||
change(fake, {"geo_trigger_ips": 0.3}, revision=r.plan["revision"])
|
||||
assert fake.executed == []
|
||||
|
||||
|
||||
# Final review #1: the revision covers the changes previewed, not only the unit.
|
||||
def test_s4_a_revision_covers_the_changes_previewed():
|
||||
fake = FakeMicromateClient()
|
||||
rev = change(fake, {"job_number": 7}, dry_run=True).plan["revision"]
|
||||
with pytest.raises(SettingsChanged):
|
||||
change(fake, {"geo_trigger_ips": 0.3}, revision=rev)
|
||||
assert fake.executed == []
|
||||
|
||||
|
||||
# Ruling (final review, declined-to-judge): the blocks a push only echoes are
|
||||
# re-read at send and sent as read, so they are not part of the revision.
|
||||
def test_s4_an_echoed_block_moving_does_not_stale_the_preview():
|
||||
fake = FakeMicromateClient()
|
||||
rev = change(fake, {"geo_trigger_ips": 0.3}, dry_run=True).plan["revision"]
|
||||
from micromate.setup_block import with_crc
|
||||
prefs = bytearray(fake.prefs)
|
||||
prefs[31] ^= 0x01
|
||||
fake.prefs = with_crc(bytes(prefs))
|
||||
assert change(fake, {"geo_trigger_ips": 0.3}, revision=rev).verified == "ok"
|
||||
@@ -0,0 +1,70 @@
|
||||
"""DeviceAccess.change_settings (phase 5): the series-independent entry point --
|
||||
what it refuses before any I/O, and that it dispatches a change (never retried)."""
|
||||
from __future__ import annotations
|
||||
|
||||
import os
|
||||
import sys
|
||||
|
||||
import pytest
|
||||
|
||||
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
|
||||
|
||||
from device_access_fakes import FakeMiniMateClient, FakeMicromateClient # noqa: E402
|
||||
from sfm.device_access.access import DeviceAccess # noqa: E402
|
||||
from sfm.device_access.errors import BadRequest, NotSupported # noqa: E402
|
||||
from sfm.device_access.models import UnitAddress # noqa: E402
|
||||
|
||||
ADDR = UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None)
|
||||
|
||||
|
||||
class Audit:
|
||||
def __init__(self):
|
||||
self.rows = {}
|
||||
|
||||
def begin(self, **f):
|
||||
cid = f"c{len(self.rows) + 1}"
|
||||
self.rows[cid] = dict(f, outcome="pending")
|
||||
return cid
|
||||
|
||||
def finish(self, cid, **f):
|
||||
self.rows[cid].update(f)
|
||||
|
||||
|
||||
def _never(*a, **kw):
|
||||
raise AssertionError("no connection may be opened")
|
||||
|
||||
|
||||
def _access(s3=_never, s4=_never, audit="default"):
|
||||
return DeviceAccess(s3_client_factory=s3, s4_client_factory=s4, start_reaper=False,
|
||||
audit=Audit() if audit == "default" else audit, sleep=lambda s: None)
|
||||
|
||||
|
||||
def test_live_change_without_revision_is_refused_before_io():
|
||||
with pytest.raises(BadRequest, match="preview first"):
|
||||
_access().change_settings(ADDR, "UM20147", changes={"job_number": 7}, revision=None)
|
||||
|
||||
|
||||
@pytest.mark.parametrize("changes", [{}, None, "job_number=7"])
|
||||
def test_empty_changes_is_a_bad_request(changes):
|
||||
with pytest.raises(BadRequest):
|
||||
_access().change_settings(ADDR, "BE18193", changes=changes, revision="r", dry_run=True)
|
||||
|
||||
|
||||
def test_a_live_change_without_an_audit_log_is_refused():
|
||||
with pytest.raises(NotSupported, match="audit"):
|
||||
_access(audit=None).change_settings(ADDR, "BE18193", changes={"job_number": 7}, revision="r")
|
||||
|
||||
|
||||
def test_change_settings_dispatches_by_series_with_change_true(monkeypatch):
|
||||
access = _access(s3=lambda a, **kw: FakeMiniMateClient(), s4=lambda a, **kw: FakeMicromateClient())
|
||||
seen = []
|
||||
real = access._dispatch
|
||||
|
||||
def spy(address, serial, s3_op, s4_op, *, change=False):
|
||||
seen.append((serial, change))
|
||||
return real(address, serial, s3_op, s4_op, change=change)
|
||||
monkeypatch.setattr(access, "_dispatch", spy)
|
||||
r3 = access.change_settings(ADDR, "be18193", changes={"job_number": 7}, revision=None, dry_run=True)
|
||||
r4 = access.change_settings(ADDR, "UM20147", changes={"job_number": 7}, revision=None, dry_run=True)
|
||||
assert (r3.series, r4.series) == (3, 4) and r3.outcome == r4.outcome == "dry_run"
|
||||
assert seen == [("BE18193", True), ("UM20147", True)]
|
||||
@@ -426,11 +426,12 @@ def test_the_units_range_reaches_the_store(tmp_path):
|
||||
assert store.geo_range == 1
|
||||
|
||||
|
||||
# Review finding (2026-10-29): a histogram's row is stored at its file's time,
|
||||
# a second before the unit's 0C time on most histograms (#51) -- K441LTOK.QZ0
|
||||
# decodes to 16:06:34, its 0C says 16:06:35 -- so a pre-check on the 0C time
|
||||
# alone missed it, and a live download overwrote the watcher's row and sidecar.
|
||||
# The Blastware name encodes the event's own second and does not miss.
|
||||
# Review finding (2026-10-29): a histogram's row was stored at its file's time,
|
||||
# a second before the unit's 0C time (#51) -- K441LTOK.QZ0 decoded to 16:06:34,
|
||||
# its 0C says 16:06:35 -- so a pre-check on the 0C time alone missed it, and a
|
||||
# live download overwrote the watcher's row and sidecar. Since #51 (dev,
|
||||
# 2026-11-03) the file decodes the event's own second, so the time matches too;
|
||||
# the Blastware name, which encodes that second, stays as the second guard.
|
||||
|
||||
@pytest.mark.parametrize("stored_as", ["K441LTOK.QZ0", "K441LTOK.QZ0H"]) # direct / call-in name
|
||||
def test_a_live_histogram_the_watcher_already_stored_writes_nothing(sdm, stored_as):
|
||||
@@ -442,7 +443,7 @@ def test_a_live_histogram_the_watcher_already_stored_writes_nothing(sdm, stored_
|
||||
db.insert_events([ev], serial="BE9441", waveform_records={ev._waveform_key.hex(): rec},
|
||||
device_family="series3") # as the import route (server.py) does
|
||||
[row0] = db.query_events(serial="BE9441")
|
||||
assert row0["timestamp"] != "2026-10-26T16:06:35" # the case: the row sits a second off
|
||||
assert row0["timestamp"] == "2026-10-26T16:06:35" # #51: the event's own second
|
||||
assert row0["blastware_filename"] == stored_as
|
||||
out = persist_download(_hist_download("K441LTOK.QZ0", "01110000",
|
||||
datetime.datetime(2026, 10, 26, 16, 6, 35)), store=store, db=db)
|
||||
@@ -498,3 +499,45 @@ def test_a_letterless_stored_name_still_matches_a_lettered_download(sdm):
|
||||
store, db = sdm
|
||||
_stored_as(store, db, "K441LTOK.QZ0")
|
||||
assert db.find_event_by_blastware_name("BE9441", "K441LTOK.QZ0H")["blastware_filename"] == "K441LTOK.QZ0"
|
||||
|
||||
|
||||
# #51 (dev, 2026-11-03): a waveform and a histogram recorded in the same second
|
||||
# are two events (UNIQUE(serial, timestamp, record_type)). A live download of one
|
||||
# must not be skipped because its twin is stored -- not by the time, and not by a
|
||||
# letterless Blastware name both twins share. An untyped row at that second still
|
||||
# counts as stored (conservatively: it may be this event).
|
||||
|
||||
def _stored_twin(store, db, name, record_type):
|
||||
ev, rec = store.save_imported_bw((HIST_FIX / "K441LTOK.QZ0").read_bytes(),
|
||||
source_path=Path(name), serial_hint=None,
|
||||
bw_report_text=(HIST_FIX / "K441LTOK_QZ0_ASCII.TXT").read_bytes())
|
||||
ev.record_type = record_type
|
||||
db.insert_events([ev], serial="BE9441", waveform_records={ev._waveform_key.hex(): rec},
|
||||
device_family="series3")
|
||||
|
||||
|
||||
@pytest.mark.parametrize("twin_name", ["K441LTOK.QZ0W", "K441LTOK.QZ0"]) # call-in / direct name
|
||||
def test_a_live_histogram_is_stored_beside_its_same_second_waveform_twin(sdm, twin_name):
|
||||
store, db = sdm
|
||||
_stored_twin(store, db, twin_name, "Waveform")
|
||||
dl = _hist_download("K441LTOK.QZ0", "01110000", datetime.datetime(2026, 10, 26, 16, 6, 35))
|
||||
dl.filename = "K441LTOK.QZ0H" # a live download carries the letter (s3.py: with_type_letter)
|
||||
out = persist_download(dl, store=store, db=db)
|
||||
assert out.inserted is True
|
||||
assert sorted(r["record_type"] for r in db.query_events(serial="BE9441")) == ["Histogram", "Waveform"]
|
||||
|
||||
|
||||
def test_an_untyped_row_at_that_second_still_counts_as_stored(sdm):
|
||||
store, db = sdm
|
||||
_stored_twin(store, db, "K441LTOK.QZ0", None)
|
||||
out = persist_download(_hist_download("K441LTOK.QZ0", "01110000",
|
||||
datetime.datetime(2026, 10, 26, 16, 6, 35)), store=store, db=db)
|
||||
assert out.inserted is False and out.detail["already_stored"] is True
|
||||
|
||||
|
||||
def test_the_name_lookup_can_be_held_to_a_record_type(sdm):
|
||||
store, db = sdm
|
||||
_stored_twin(store, db, "K441LTOK.QZ0", "Waveform")
|
||||
assert db.find_event_by_blastware_name("BE9441", "K441LTOK.QZ0H", record_type="Histogram") is None
|
||||
assert db.find_event_by_blastware_name("BE9441", "K441LTOK.QZ0", record_type="waveform") is not None
|
||||
assert db.find_event_by_blastware_name("BE9441", "K441LTOK.QZ0") is not None
|
||||
@@ -0,0 +1,123 @@
|
||||
"""An event is identified by unit + time + type (#51).
|
||||
|
||||
The events table was unique on (serial, timestamp): one event per unit per
|
||||
second. A unit records a waveform and a histogram in the same second
|
||||
legitimately -- 209 times in prod's 2026-09-30 store once histograms carry
|
||||
Blastware's start -- so the key is now (serial, timestamp, record_type).
|
||||
Agreed with Brian 2026-11-03.
|
||||
"""
|
||||
from __future__ import annotations
|
||||
|
||||
import datetime
|
||||
import os
|
||||
import sqlite3
|
||||
import sys
|
||||
|
||||
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
|
||||
|
||||
from minimateplus.models import Event, PeakValues, Timestamp # noqa: E402
|
||||
from sfm.database import SeismoDb # noqa: E402
|
||||
|
||||
T = "2026-08-25T10:33:29"
|
||||
T_EARLY = "2026-08-25T10:33:28"
|
||||
|
||||
|
||||
def _event(when: str, rtype: str, key: str = "0111646a", pvs: float = 0.5) -> Event:
|
||||
t = datetime.datetime.fromisoformat(when)
|
||||
ev = Event(index=0)
|
||||
ev.timestamp = Timestamp(raw=b"", flag=0x10, year=t.year, unknown_byte=0, month=t.month,
|
||||
day=t.day, hour=t.hour, minute=t.minute, second=t.second)
|
||||
ev._waveform_key = bytes.fromhex(key)
|
||||
ev.record_type = rtype
|
||||
ev.peak_values = PeakValues(tran=0.1, vert=0.2, long=0.3, peak_vector_sum=pvs, micl=None)
|
||||
return ev
|
||||
|
||||
|
||||
def _store(db: SeismoDb, ev: Event, filename: str) -> tuple:
|
||||
return db.insert_events([ev], serial="BE12844", device_family="series3",
|
||||
waveform_records={ev._waveform_key.hex(): {"filename": filename}})
|
||||
|
||||
|
||||
def _rows(db: SeismoDb) -> list:
|
||||
with sqlite3.connect(str(db.db_path)) as c:
|
||||
c.row_factory = sqlite3.Row
|
||||
return [dict(r) for r in c.execute(
|
||||
"SELECT * FROM events ORDER BY timestamp, record_type")]
|
||||
|
||||
|
||||
def _key_sql(db: SeismoDb) -> str:
|
||||
with sqlite3.connect(str(db.db_path)) as c:
|
||||
return c.execute("SELECT sql FROM sqlite_master WHERE type='table' AND name='events'"
|
||||
).fetchone()[0]
|
||||
|
||||
|
||||
def test_a_waveform_and_a_histogram_can_share_a_second(tmp_path):
|
||||
db = SeismoDb(tmp_path / "seismo_relay.db")
|
||||
assert _store(db, _event(T, "Waveform"), "N844LQHB.ZT0W") == (1, 0)
|
||||
assert _store(db, _event(T, "Histogram", key="0111700a"), "N844LQHB.ZT0H") == (1, 0)
|
||||
assert [(r["timestamp"], r["record_type"]) for r in _rows(db)] == [
|
||||
(T, "Histogram"), (T, "Waveform")]
|
||||
|
||||
|
||||
def test_the_same_event_twice_is_still_one_row(tmp_path):
|
||||
db = SeismoDb(tmp_path / "seismo_relay.db")
|
||||
_store(db, _event(T, "Histogram"), "N844LQHB.ZT0H")
|
||||
assert _store(db, _event(T, "Histogram", pvs=0.8), "N844LQHB.ZT0H") == (0, 1)
|
||||
(row,) = _rows(db)
|
||||
assert row["peak_vector_sum"] == 0.8 # the upsert refreshed it
|
||||
|
||||
|
||||
def test_a_histogram_moves_onto_its_waveforms_second(tmp_path):
|
||||
# What the release backfill does: the histogram was stored a second early;
|
||||
# its corrected start is the waveform's second. The row moves in place.
|
||||
db = SeismoDb(tmp_path / "seismo_relay.db")
|
||||
_store(db, _event(T, "Waveform"), "N844LQHB.ZT0W")
|
||||
_store(db, _event(T_EARLY, "Histogram", key="0111700a"), "N844LQHB.ZS0H")
|
||||
(before,) = [r for r in _rows(db) if r["record_type"] == "Histogram"]
|
||||
assert _store(db, _event(T, "Histogram", key="0111700a"), "N844LQHB.ZS0H") == (0, 1)
|
||||
rows = _rows(db)
|
||||
assert [(r["timestamp"], r["record_type"]) for r in rows] == [(T, "Histogram"), (T, "Waveform")]
|
||||
assert [r["id"] for r in rows if r["record_type"] == "Histogram"] == [before["id"]]
|
||||
|
||||
|
||||
def test_a_re_typed_event_is_corrected_in_place(tmp_path):
|
||||
# Before v0.33.0 the type came from the filename; a re-import with the
|
||||
# file's own type must correct that row, not add a second one.
|
||||
db = SeismoDb(tmp_path / "seismo_relay.db")
|
||||
_store(db, _event(T, "Waveform"), "N844LQHB.ZT0H")
|
||||
(before,) = _rows(db)
|
||||
_store(db, _event(T, "Histogram"), "N844LQHB.ZT0H")
|
||||
(row,) = _rows(db)
|
||||
assert (row["id"], row["record_type"]) == (before["id"], "Histogram")
|
||||
|
||||
|
||||
def test_an_old_database_is_migrated_keeping_every_row_and_id(tmp_path):
|
||||
db = SeismoDb(tmp_path / "seismo_relay.db")
|
||||
_store(db, _event(T, "Waveform"), "N844LQHB.ZT0W")
|
||||
_store(db, _event(T_EARLY, "Histogram", key="0111700a"), "N844LQHB.ZS0H")
|
||||
old_rows = _rows(db)
|
||||
with sqlite3.connect(str(db.db_path)) as c: # put the old key back
|
||||
sql = _key_sql(db).replace("UNIQUE(serial, timestamp, record_type)",
|
||||
"UNIQUE(serial, timestamp)")
|
||||
c.executescript(f"""
|
||||
ALTER TABLE events RENAME TO events_new_key;
|
||||
{sql};
|
||||
INSERT INTO events SELECT * FROM events_new_key;
|
||||
DROP TABLE events_new_key;
|
||||
""")
|
||||
assert "UNIQUE(serial, timestamp)" in _key_sql(db)
|
||||
|
||||
db = SeismoDb(tmp_path / "seismo_relay.db") # opening migrates
|
||||
assert "UNIQUE(serial, timestamp, record_type)" in _key_sql(db)
|
||||
assert _rows(db) == old_rows
|
||||
assert _store(db, _event(T, "Histogram", key="0111700b"), "N844LQHC.ZT0H") == (1, 0)
|
||||
with sqlite3.connect(str(db.db_path)) as c:
|
||||
names = {r[0] for r in c.execute(
|
||||
"SELECT name FROM sqlite_master WHERE type='index' AND tbl_name='events'")}
|
||||
assert {"idx_events_serial", "idx_events_timestamp"} <= names
|
||||
|
||||
|
||||
def test_reopening_keeps_the_new_key(tmp_path):
|
||||
SeismoDb(tmp_path / "seismo_relay.db")
|
||||
db = SeismoDb(tmp_path / "seismo_relay.db")
|
||||
assert "UNIQUE(serial, timestamp, record_type)" in _key_sql(db)
|
||||
@@ -22,7 +22,7 @@ from minimateplus.models import Event
|
||||
|
||||
FIX = Path(__file__).parent / "fixtures"
|
||||
WAVEFORM = FIX / "fft-oracle-2026-09-14" / "N844LQHB.ZT0W" # footer ts2 = 2026-08-25 10:33:32
|
||||
HISTOGRAM = FIX / "ts-fix" / "K441LKZU.C30H" # window start 2026-05-10 19:04:50
|
||||
HISTOGRAM = FIX / "ts-fix" / "K441LKZU.C30H" # start 2026-05-10 19:04:51 (#51)
|
||||
|
||||
|
||||
def _tuple(ts):
|
||||
@@ -39,9 +39,10 @@ def test_waveform_timestamp_is_exact_trigger_from_binary():
|
||||
|
||||
def test_histogram_timestamp_is_window_start_unchanged():
|
||||
ev = read_blastware_file(HISTOGRAM)
|
||||
# Histogram event time = the window start (ts1); must NOT get the waveform
|
||||
# ts2 treatment (that would land ~24 h off).
|
||||
assert _tuple(ev.timestamp) == (2026, 5, 10, 19, 4, 50), _tuple(ev.timestamp)
|
||||
# Histogram event time = the window start, from its own event record (#51;
|
||||
# the footer's ts1 is a second earlier); must NOT get the waveform ts2
|
||||
# treatment (that would land ~24 h off).
|
||||
assert _tuple(ev.timestamp) == (2026, 5, 10, 19, 4, 51), _tuple(ev.timestamp)
|
||||
|
||||
|
||||
def test_a_report_does_not_override_the_instruments_event_record():
|
||||
|
||||
@@ -695,3 +695,10 @@ def test_third_block_still_rejects_a_mismatched_counter():
|
||||
+ _mk_multi_block(ivs, ctr=257)
|
||||
+ _mk_multi_block(ivs, ctr=999)) # counter jumps — not consecutive
|
||||
assert detect_multi_interval_stride(body) != 12 + 20 * 4
|
||||
|
||||
|
||||
def test_half_period_to_hz_follows_the_sample_rate():
|
||||
"""#50: (sample rate / 2) / half-period, measured on 1,725 / 1,725 cells at
|
||||
2048 sps; the old fixed 512 halved them."""
|
||||
assert half_period_to_hz(6, 2048) == pytest.approx(1024 / 6)
|
||||
assert half_period_to_hz(6) == pytest.approx(512 / 6) # 1024 sps by default
|
||||
@@ -33,9 +33,11 @@ def _ready(responses):
|
||||
return p, t
|
||||
|
||||
|
||||
def test_the_ceiling_is_start_stop_and_call_home():
|
||||
# Phase 4 (2026-11-02) added the call-home write and its confirm.
|
||||
assert ENABLEABLE_WRITES == frozenset({0x96, 0x97, 0x7E, 0x7F})
|
||||
def test_the_ceiling_is_start_stop_call_home_and_the_setup_push():
|
||||
# Phase 4 (2026-11-02) added the call-home write and its confirm; phase 5
|
||||
# (2026-11-03) the setup push: name, preferences, trigger, setup, confirms.
|
||||
assert ENABLEABLE_WRITES == frozenset({0x96, 0x97, 0x7E, 0x7F,
|
||||
0xDA, 0x68, 0x73, 0x82, 0x83, 0x71, 0x72})
|
||||
|
||||
|
||||
def test_execute_sends_exactly_the_plans_frame_and_returns_the_ack():
|
||||
@@ -54,10 +56,10 @@ def test_permission_ends_with_the_call():
|
||||
|
||||
|
||||
def test_a_plan_beyond_the_ceiling_is_refused_and_nothing_is_sent():
|
||||
# 0x71 (the setup-block write) stays above the ceiling until phase 5.
|
||||
# 0xA8 (delete one event) stays above the ceiling (0x71 joined it in phase 5).
|
||||
p, t = _ready([])
|
||||
with pytest.raises(OpcodeRefused, match="ceiling"):
|
||||
p.execute(WritePlan("setup push", (WriteStep(0x71, 0x0000, bytes(4)),)))
|
||||
p.execute(WritePlan("delete", (WriteStep(0xA8, 0x0000, bytes(4)),)))
|
||||
assert t.written == []
|
||||
|
||||
|
||||
@@ -111,7 +113,7 @@ def test_a_duck_typed_plan_is_refused():
|
||||
def test_a_forged_step_in_a_real_plan_is_refused_at_the_step():
|
||||
p, t = _ready([])
|
||||
plan = plan_start_monitoring()
|
||||
object.__setattr__(plan, "steps", (WriteStep(0x71, 0),)) # subs now reads 0x71 too
|
||||
object.__setattr__(plan, "steps", (WriteStep(0xA8, 0),)) # subs now reads 0xA8 too
|
||||
with pytest.raises(OpcodeRefused):
|
||||
p.execute(plan)
|
||||
assert t.written == []
|
||||
@@ -122,7 +124,7 @@ def test_a_forged_step_hidden_behind_a_good_plan_is_refused():
|
||||
@property
|
||||
def subs(self):
|
||||
return frozenset({0x96})
|
||||
plan = Lying("x", (WriteStep(0x96, 0xFFFF), WriteStep(0x71, 0)))
|
||||
plan = Lying("x", (WriteStep(0x96, 0xFFFF), WriteStep(0xA8, 0)))
|
||||
p, t = _ready([ACK_START])
|
||||
with pytest.raises(OpcodeRefused):
|
||||
p.execute(plan)
|
||||
|
||||
@@ -81,7 +81,7 @@ def test_a_frame_that_is_not_a_request_is_refused_not_sent():
|
||||
|
||||
def test_every_protocol_read_sub_is_in_the_read_table():
|
||||
consts = {k: v for k, v in vars(mm_proto).items() if k.startswith("SUB_")}
|
||||
assert len(consts) == 19
|
||||
assert len(consts) == 21 # + 0x48 and 0x94, the file read (phase 5)
|
||||
assert set(consts.values()) <= set(READ_SUBS)
|
||||
assert {0x94, 0x48} <= set(READ_SUBS)
|
||||
|
||||
@@ -98,7 +98,7 @@ def test_an_unknown_opcode_is_refused_and_nothing_is_written(sub):
|
||||
assert t.written == []
|
||||
|
||||
|
||||
@pytest.mark.parametrize("sub", [0xEE, 0x71, 0xA8]) # 0x71 (setup write) stays above the ceiling until phase 5
|
||||
@pytest.mark.parametrize("sub", [0xEE, 0xA8, 0xAA]) # delete and its confirm stay above the ceiling
|
||||
def test_a_permit_beyond_the_ceiling_is_refused_at_the_wire(sub):
|
||||
p, t = proto([])
|
||||
with pytest.raises(OpcodeRefused):
|
||||
|
||||
@@ -0,0 +1,142 @@
|
||||
"""Reading a Micromate's schedule file, read-only (phase 5).
|
||||
|
||||
A Micromate's scheduled start loads the setup it names, so a settings change to
|
||||
another setup would be undone at the next start: SFM reads the schedule to refuse
|
||||
that case. Ground truth is THOR's 2026-09-24/25 captures of UM12947
|
||||
(bridges/captures/9-24-26 - micromate2): its read of `schedule.dat` (0x94, then
|
||||
0x48 pages) and its writes of a two- and a five-entry schedule (0x8E bodies).
|
||||
"""
|
||||
from __future__ import annotations
|
||||
|
||||
import os
|
||||
import sys
|
||||
from pathlib import Path
|
||||
|
||||
import pytest
|
||||
|
||||
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
|
||||
|
||||
from micromate.client import MicromateClient # noqa: E402
|
||||
from micromate.framing import MicromateFrameParser, unstuff # noqa: E402
|
||||
from micromate.protocol import MicromateProtocol # noqa: E402
|
||||
from micromate.schedule import ( # noqa: E402
|
||||
SCHEDULE_PATH, ScheduleEntry, parse_schedule, schedule_conflicts,
|
||||
)
|
||||
from test_micromate_protocol import ScriptedTransport, frame # noqa: E402
|
||||
from test_minimate_write_frames import _frames # noqa: E402
|
||||
|
||||
D = Path(__file__).resolve().parent.parent / "bridges" / "captures" / "9-24-26 - micromate2"
|
||||
READ_S3 = D / "raw_s3_20260924_191835_read_scheduler.bin"
|
||||
READ_BW = D / "raw_bw_20260924_191835_read_scheduler.bin"
|
||||
ACTIONCHECK_BW = D / "raw_bw_20260925_005122_actioncheck.bin"
|
||||
pytestmark = pytest.mark.skipif(not D.is_dir(), reason="bridges/captures is not on this machine")
|
||||
|
||||
|
||||
def _payloads(path: Path) -> list:
|
||||
return [unstuff(f[2:-1])[:-1] for f in _frames(path.read_bytes())]
|
||||
|
||||
|
||||
def _written_schedule(path: Path) -> bytes:
|
||||
"""The schedule body THOR wrote: the 0x8E chunks after the 0x8D that opens
|
||||
schedule.dat, joined (a long body goes in 1,024-byte pieces)."""
|
||||
body, current = b"", None
|
||||
for p in _payloads(path):
|
||||
if p[2] == 0x8D:
|
||||
current = p[16:] == SCHEDULE_PATH.encode("ascii")
|
||||
elif p[2] == 0x8E and current:
|
||||
body += p[16:]
|
||||
return body
|
||||
|
||||
|
||||
def _read_replies() -> list:
|
||||
"""The unit's replies to THOR's schedule read: 0x6B, then three 0xB7 pages."""
|
||||
fr = MicromateFrameParser().feed(READ_S3.read_bytes())
|
||||
i = next(k for k, f in enumerate(fr) if f.sub == 0x6B)
|
||||
return fr[i:i + 4]
|
||||
|
||||
|
||||
def test_the_read_capture_parses():
|
||||
body = bytes(_read_replies()[2].data)[11:]
|
||||
assert len(body) == 524
|
||||
e = parse_schedule(body)
|
||||
assert [(x.time, x.actions) for x in e] == [("07:30", ("start_with_setup",)), ("19:30", ("call_home",))]
|
||||
assert len(e[0].setup) == 40 and e[1].setup == ""
|
||||
assert e[0].day == 3 and e[0].action_bits == 2
|
||||
|
||||
|
||||
def test_the_five_entry_schedule_parses():
|
||||
e = parse_schedule(_written_schedule(ACTIONCHECK_BW))
|
||||
assert [(x.time, x.actions, x.setup) for x in e] == [
|
||||
("07:30", ("start_with_setup",), "TEST1.mmb"),
|
||||
("08:00", ("stop",), ""),
|
||||
("08:30", ("self_check",), ""),
|
||||
("09:00", ("start_with_setup",), "test2.mmb"),
|
||||
("19:30", ("call_home",), ""),
|
||||
]
|
||||
|
||||
|
||||
def test_conflicts_are_case_insensitive():
|
||||
e = parse_schedule(_written_schedule(ACTIONCHECK_BW))
|
||||
assert [x.setup for x in schedule_conflicts(e, "test1.MMB")] == ["test2.mmb"]
|
||||
assert [x.setup for x in schedule_conflicts(e, " TEST2.mmb ")] == ["TEST1.mmb"]
|
||||
|
||||
|
||||
def test_no_schedule_records_is_no_conflict():
|
||||
assert parse_schedule(bytes(524)) == []
|
||||
assert schedule_conflicts(parse_schedule(bytes(524)), "x.mmb") == []
|
||||
|
||||
|
||||
def test_an_unknown_action_bit_is_named_not_dropped():
|
||||
rec = bytearray(260)
|
||||
rec[4], rec[5], rec[6] = 14, 3, 0x01 # 07:00, the setup-less start THOR never sends?
|
||||
(e,) = parse_schedule(bytes(rec))
|
||||
assert e.actions == ("unknown(0x01)",) and e.setup == ""
|
||||
assert schedule_conflicts([e], "a.mmb") == [] # no setup named: nothing to undo the change
|
||||
|
||||
|
||||
def test_read_file_sends_thors_frames_and_stops_at_zeros():
|
||||
replies = [frame(f.sub, bytes(f.data), flags=f.flags, page=f.page_key) for f in _read_replies()]
|
||||
t = ScriptedTransport(replies)
|
||||
body = MicromateProtocol(t, recv_timeout=0.5).read_file(SCHEDULE_PATH)
|
||||
thor = [f for f in _frames(READ_BW.read_bytes()) if unstuff(f[2:-1])[2] in (0x94, 0x48)]
|
||||
assert t.written == thor[:4] # 0x94 + path, 0x48 (first page), 0x48, 0x48
|
||||
assert body == bytes(_read_replies()[2].data)[11:]
|
||||
|
||||
|
||||
class _Proto:
|
||||
def __init__(self, data: bytes):
|
||||
self.data = data
|
||||
|
||||
def read_active_setup_name(self):
|
||||
return self.data
|
||||
|
||||
def read_event_index(self):
|
||||
return self.data
|
||||
|
||||
def read_trigger_config(self):
|
||||
return self.data
|
||||
|
||||
def read_compliance_config(self):
|
||||
return self.data
|
||||
|
||||
|
||||
def _client(data: bytes) -> MicromateClient:
|
||||
c = MicromateClient.__new__(MicromateClient)
|
||||
c._proto = _Proto(data)
|
||||
return c
|
||||
|
||||
|
||||
def test_get_active_setup_raw_keeps_spaces():
|
||||
c = _client(bytes(11) + b" LOC 4 .mmb \x00junk")
|
||||
assert c.get_active_setup_raw() == " LOC 4 .mmb "
|
||||
assert c.get_active_setup() == "LOC 4 .mmb"
|
||||
|
||||
|
||||
def test_block_content_getters_strip_the_prefix():
|
||||
c = _client(bytes(range(11)) + b"content")
|
||||
assert c.get_prefs_content() == c.get_trigger_content() == c.get_setup_content() == b"content"
|
||||
|
||||
|
||||
def test_schedule_entry_is_a_value():
|
||||
assert ScheduleEntry(0, "07:00", 3, 2, ("start_with_setup",), "a") == \
|
||||
ScheduleEntry(0, "07:00", 3, 2, ("start_with_setup",), "a")
|
||||
@@ -193,12 +193,22 @@ def test_steps_cannot_be_reassigned():
|
||||
|
||||
def test_call_home_off_from_an_unobserved_start_value_carries_a_warning():
|
||||
r = bytearray(_call_home_reads()[0])
|
||||
r[5] = 0x01 # UM20147 reads 0x01, not THOR's 0x04/0x05
|
||||
r[5] = 0x03 # a value no unit has been seen holding
|
||||
plan = plan_call_home_enabled(bytes(r), False)
|
||||
assert any("unobserved" in w and "0x01 -> 0x00" in w for w in plan.warnings)
|
||||
assert any("unobserved" in w and "0x03 -> 0x02" in w for w in plan.warnings)
|
||||
assert plan.describe()["warnings"] and plan.describe()["warnings"] == list(plan.warnings)
|
||||
|
||||
|
||||
@pytest.mark.parametrize("start,enabled", [(0x01, False), (0x00, True)])
|
||||
def test_um20147s_values_are_observed_since_the_bench(start, enabled):
|
||||
# Bench 2026-11-03 (UM20147): 0x01 -> 0x00 and 0x00 -> 0x01 both acknowledged, read
|
||||
# back, and matched in the unit's own menu (and again 2026-11-04).
|
||||
r = bytearray(_call_home_reads()[0])
|
||||
r[5] = start
|
||||
plan = plan_call_home_enabled(bytes(r), enabled)
|
||||
assert not any("unobserved" in w for w in plan.warnings)
|
||||
|
||||
|
||||
def test_call_home_on_when_already_on_says_it_changes_nothing():
|
||||
r = next(x for x in _call_home_reads() if x[5] == 0x05)
|
||||
plan = plan_call_home_enabled(r, True)
|
||||
|
||||
@@ -213,40 +213,8 @@ def test_each_read_returns_the_block_blastware_then_wrote(read, sub, size):
|
||||
assert block[:-2] == want[:-2] if sub == 0x69 else block == want[:-2]
|
||||
|
||||
|
||||
# -- apply_config writes this unit's own trigger block ---------------------------
|
||||
|
||||
class StubProto:
|
||||
"""Serves BE9441's blocks as read on 2026-10-26; records every write."""
|
||||
|
||||
def __init__(self):
|
||||
self.writes = []
|
||||
|
||||
def read_event_index(self):
|
||||
return _image(0x68)[:-2]
|
||||
|
||||
def read_compliance_config(self):
|
||||
return _image(0x71)[:-2]
|
||||
|
||||
def read_waveform_data_raw(self):
|
||||
return _image(0x69)
|
||||
|
||||
def read_trigger_config(self):
|
||||
return _image(0x82)[:-2]
|
||||
|
||||
def __getattr__(self, name):
|
||||
if name.startswith("write_"):
|
||||
return lambda *a, **k: self.writes.append((name, a))
|
||||
raise AttributeError(name)
|
||||
|
||||
|
||||
def test_apply_config_writes_the_units_own_trigger_block():
|
||||
from minimateplus.client import MiniMateClient
|
||||
c = MiniMateClient(transport=object())
|
||||
c._proto = StubProto()
|
||||
c.apply_config() # nothing changed: a round trip
|
||||
trig = [a[0] for n, a in c._proto.writes if n == "write_trigger_config"]
|
||||
assert trig == [_image(0x82)[:-2]]
|
||||
assert trig[0][5] == 0x01 # BE9441's; the March copy had 0x03
|
||||
# -- the unit's own trigger block is sent back: tests/test_device_access_s3_settings.py
|
||||
# (test_s3_trigger_change_sends_the_units_own_blocks), phase 5.
|
||||
|
||||
|
||||
def test_a_bad_block_is_refused_before_the_first_write_goes_out():
|
||||
|
||||
@@ -96,30 +96,5 @@ def test_a_reply_without_the_settings_block_reads_as_unknown():
|
||||
(None, None, None, None)
|
||||
|
||||
|
||||
# The write side (review finding, 2026-10-29). _encode_compliance_config patches
|
||||
# the RAW bytes at offsets measured at 1024 sps (April 2026), where an escape sits
|
||||
# between the mode and the anchor. At other rates the mode is one byte later, so
|
||||
# a mode change rewrote the byte in front of it. A payload that would not read
|
||||
# back as asked is refused before anything is sent.
|
||||
|
||||
from minimateplus.client import _encode_compliance_config # noqa: E402
|
||||
|
||||
|
||||
def _block(i):
|
||||
return _settings_replies()[i].ljust(2126, b"\x00") # a whole block's length
|
||||
|
||||
|
||||
@pytest.mark.parametrize("i, change", [
|
||||
(0, {"recording_mode": 0}), # 10-25 Continuous / 4096: mode sits at -7, not -8
|
||||
(1, {"sample_rate": 4096}), # 10-26 Histogram+Continuous / 2048: escaped mode shifts the rate
|
||||
])
|
||||
def test_a_change_that_would_not_read_back_is_refused(i, change):
|
||||
with pytest.raises(ValueError, match="read back"):
|
||||
_encode_compliance_config(_block(i), **change)
|
||||
|
||||
|
||||
def test_a_change_that_reads_back_as_asked_is_built():
|
||||
out = _encode_compliance_config(_block(0), record_time=7.0)
|
||||
cc = _decode(out)
|
||||
assert (cc.recording_mode, cc.sample_rate, cc.histogram_interval_sec, cc.record_time) == \
|
||||
(1, 4096, 5, 7.0)
|
||||
# The write side moved to the shared settings codec in phase 5 (2026-11-03):
|
||||
# tests/test_setup_fields.py reproduces every Blastware write byte for byte.
|
||||
@@ -0,0 +1,151 @@
|
||||
"""A MiniMate's settings read, assembled into the logical 2,090-byte block (phase 5).
|
||||
|
||||
Measured 2026-11-03 on BE9441's 10-26 recording (12 reads): unescape each 1A
|
||||
data frame and take data[11:]; every frame but the last starts with one `00`
|
||||
that is not content -- drop it. The result is the block Blastware writes back:
|
||||
the read after each of its two writes equals the image it had just written.
|
||||
While monitoring, the unit answers with its device-info block instead.
|
||||
"""
|
||||
from __future__ import annotations
|
||||
|
||||
import os
|
||||
import sys
|
||||
from pathlib import Path
|
||||
|
||||
import pytest
|
||||
|
||||
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
|
||||
|
||||
import minimateplus.protocol as mp # noqa: E402
|
||||
from minimateplus.framing import S3FrameParser # noqa: E402
|
||||
from minimateplus.protocol import ( # noqa: E402
|
||||
COMPLIANCE_CONTENT_LEN, assemble_compliance_content, is_compliance_content,
|
||||
)
|
||||
from test_minimate_write_frames import WRITES, _payload # noqa: E402
|
||||
|
||||
FIX = Path(__file__).parent / "fixtures" / "minimate-bench-10-26-26-histogram"
|
||||
|
||||
|
||||
def _reads() -> list:
|
||||
"""Each recorded 1A read as its data frames' `data`, in order (a probe reply,
|
||||
11 bytes of data, starts each read)."""
|
||||
reads, cur = [], None
|
||||
for f in S3FrameParser().feed((FIX / "unit_replies.bin").read_bytes()):
|
||||
if f.sub != 0xE5:
|
||||
continue
|
||||
if len(f.data) == 11:
|
||||
cur = []
|
||||
reads.append(cur)
|
||||
else:
|
||||
cur.append(bytes(f.data))
|
||||
return reads
|
||||
|
||||
|
||||
READS = _reads()
|
||||
IMAGES = [b"".join(_payload(f)[16:] for f in WRITES[k:k + 13] if _payload(f)[2] == 0x71)
|
||||
for k in (0, 13)]
|
||||
|
||||
|
||||
def test_the_recording_holds_twelve_reads_in_both_patterns():
|
||||
assert len(READS) == 12
|
||||
assert sorted({len(r) for r in READS}) == [3, 5] # SFM's 1024+1024+42, Blastware's 4x512+42
|
||||
|
||||
|
||||
def test_reads_assemble_to_2090_bytes():
|
||||
assert COMPLIANCE_CONTENT_LEN == 2090
|
||||
assert all(len(assemble_compliance_content(r)) == 2090 for r in READS)
|
||||
|
||||
|
||||
def test_a_read_after_a_blastware_write_equals_the_write():
|
||||
assert assemble_compliance_content(READS[1]) == IMAGES[0][:2090]
|
||||
assert assemble_compliance_content(READS[2]) == IMAGES[1][:2090]
|
||||
|
||||
|
||||
def test_a_monitoring_units_answer_is_not_settings():
|
||||
# reads 3-7 were taken while BE9441 was monitoring: they start 0e 'BE9441'
|
||||
assert [is_compliance_content(assemble_compliance_content(r)) for r in READS[3:8]] == [False] * 5
|
||||
assert all(is_compliance_content(assemble_compliance_content(r)) for r in READS[:3] + READS[8:])
|
||||
|
||||
|
||||
def _s3_reply(sub: int, data: bytes) -> bytes:
|
||||
"""A unit reply on the wire: DLE STX, the payload with every 0x10 doubled, ETX.
|
||||
(`data` here holds no 02/03/04, so no escape is needed.)"""
|
||||
body = bytes([0x00, 0x10, sub, 0x00, 0x00]) + data
|
||||
body += bytes([sum(body) & 0xFF])
|
||||
return b"\x10\x02" + body.replace(b"\x10", b"\x10\x10") + b"\x03"
|
||||
|
||||
|
||||
class _ProbeAndOneFrame:
|
||||
"""Answers the probe and frame B, then goes silent: frame C never arrives."""
|
||||
|
||||
def __init__(self):
|
||||
self.sent = []
|
||||
self._replies = [_s3_reply(0xE5, bytes(11)), _s3_reply(0xE5, bytes(11) + bytes(1025))]
|
||||
self._buf = b""
|
||||
|
||||
def write(self, data):
|
||||
self.sent.append(bytes(data))
|
||||
if self._replies:
|
||||
self._buf += self._replies.pop(0)
|
||||
|
||||
def read(self, n):
|
||||
out, self._buf = self._buf[:n], self._buf[n:]
|
||||
return out
|
||||
|
||||
|
||||
def test_read_compliance_content_refuses_a_missing_frame():
|
||||
t = _ProbeAndOneFrame()
|
||||
proto = mp.MiniMateProtocol(t, recv_timeout=0.2)
|
||||
with pytest.raises(mp.ProtocolError):
|
||||
proto.read_compliance_content()
|
||||
assert len(t.sent) == 3 # probe, B, C -- and no D after C went unanswered
|
||||
|
||||
|
||||
# Bench 2026-11-04 (BE9441, live): frame B of a 1A read came back one byte long,
|
||||
# ending in a lone 0x10 -- the kept escape of a checksum byte that was itself
|
||||
# escaped (02 / 03 / 04: about one frame in 85); the parser strips only the byte
|
||||
# after it. The 12 recorded reads never hit it. The read knows how much it asked
|
||||
# for, so it takes exactly that; a leftover other than that one 0x10 is kept, and
|
||||
# the block then fails is_compliance_content.
|
||||
|
||||
def test_a_frame_with_an_escaped_checksums_stray_byte_is_trimmed_to_what_was_asked():
|
||||
sfm_read = READS[8] # SFM's own 1024 + 1024 + 42 pattern
|
||||
good = assemble_compliance_content(sfm_read, lengths=(1024, 1024, 42))
|
||||
assert good == assemble_compliance_content(sfm_read) and is_compliance_content(good)
|
||||
stray = [sfm_read[0] + b"\x10", sfm_read[1], sfm_read[2]]
|
||||
assert len(assemble_compliance_content(stray)) == 2091 # what the bench saw
|
||||
assert assemble_compliance_content(stray, lengths=(1024, 1024, 42)) == good
|
||||
|
||||
|
||||
def test_a_leftover_that_is_not_the_stray_escape_is_not_trimmed():
|
||||
sfm_read = READS[8]
|
||||
odd = [sfm_read[0] + b"\x55", sfm_read[1], sfm_read[2]]
|
||||
assert not is_compliance_content(assemble_compliance_content(odd, lengths=(1024, 1024, 42)))
|
||||
|
||||
|
||||
# The same artifact on the waveform-data read a settings write echoes back: it asks
|
||||
# for 0xCA = 202 bytes; one extra trailing 0x10 is the escaped checksum's DLE.
|
||||
# (Unfixed, it fails closed: the write's own block check refuses 203 bytes.)
|
||||
class _Replies:
|
||||
def __init__(self, data):
|
||||
self._data = data
|
||||
self.sent = []
|
||||
|
||||
def __call__(self, frame):
|
||||
self.sent.append(frame)
|
||||
|
||||
|
||||
def _waveform_proto(data_reply: bytes):
|
||||
from types import SimpleNamespace
|
||||
p = mp.MiniMateProtocol(object())
|
||||
p._send = _Replies(None)
|
||||
replies = [SimpleNamespace(data=bytes(11)), SimpleNamespace(data=bytes(11) + data_reply)]
|
||||
p._recv_one = lambda expected_sub=None, **kw: replies.pop(0)
|
||||
return p
|
||||
|
||||
|
||||
def test_the_waveform_read_drops_an_escaped_checksums_stray_byte():
|
||||
block = (200).to_bytes(2, "big") + bytes(range(198)) + b"\x17\x17" # N = 200, plus its 2 tail bytes
|
||||
assert _waveform_proto(block).read_waveform_data_raw() == block
|
||||
assert _waveform_proto(block + b"\x10").read_waveform_data_raw() == block
|
||||
assert _waveform_proto(block + b"\x55").read_waveform_data_raw() == block + b"\x55" # anything else is kept
|
||||
@@ -23,7 +23,7 @@ from fastapi import HTTPException # noqa: E402
|
||||
|
||||
import sfm.server as srv # noqa: E402
|
||||
|
||||
WRITES = {"delete_all_events", "apply_config", "set_call_home_config", "stop_monitoring"}
|
||||
WRITES = {"delete_all_events", "set_call_home_config", "stop_monitoring"}
|
||||
ADDR = dict(port=None, baud=38400, host="10.0.0.9", tcp_port=9034)
|
||||
|
||||
|
||||
@@ -56,9 +56,6 @@ class Unit:
|
||||
def delete_all_events(self):
|
||||
self._rec("delete_all_events")
|
||||
|
||||
def apply_config(self, **kw):
|
||||
self._rec("apply_config")
|
||||
|
||||
def set_call_home_config(self, **kw):
|
||||
self._rec("set_call_home_config")
|
||||
|
||||
@@ -72,8 +69,6 @@ class Cache:
|
||||
|
||||
|
||||
def _call(route, serial):
|
||||
if route == "config":
|
||||
return srv.device_config(body=srv.DeviceConfigBody(), serial=serial, **ADDR)
|
||||
if route == "erase":
|
||||
return srv.device_events_erase(serial=serial, **ADDR)
|
||||
if route == "rescue":
|
||||
@@ -98,7 +93,7 @@ def unit(monkeypatch):
|
||||
return make
|
||||
|
||||
|
||||
ROUTES = ["config", "erase", "rescue", "call_home"]
|
||||
ROUTES = ["erase", "rescue", "call_home"] # /device/config is retired (410)
|
||||
|
||||
|
||||
@pytest.mark.parametrize("route", ROUTES)
|
||||
@@ -131,8 +126,8 @@ def test_guarded_route_proceeds_for_the_named_series3_unit(unit, route):
|
||||
|
||||
|
||||
def test_the_identity_check_reuses_connects_serial_where_there_is_one(unit):
|
||||
# speed: config and erase already read the serial in connect(); no extra read
|
||||
for route in ("config", "erase"):
|
||||
# speed: erase already reads the serial in connect(); no extra read
|
||||
for route in ("erase",):
|
||||
u = unit("BE9441")
|
||||
_call(route, None)
|
||||
assert "read_serial" not in u.calls
|
||||
|
||||
@@ -0,0 +1,153 @@
|
||||
"""POST /device/settings/change (phase 5), and the legacy config write retired.
|
||||
Handlers are called directly, every parameter passed, as in
|
||||
test_server_device_access.py."""
|
||||
from __future__ import annotations
|
||||
|
||||
import json
|
||||
import os
|
||||
import sys
|
||||
|
||||
import pytest
|
||||
|
||||
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
|
||||
|
||||
import micromate.protocol as mm_proto # noqa: E402
|
||||
import sfm.server as srv # noqa: E402
|
||||
from device_access_fakes import FakeMicromateClient, schedule_record # noqa: E402
|
||||
from fastapi import HTTPException # noqa: E402
|
||||
from sfm.device_access.access import DeviceAccess # noqa: E402
|
||||
|
||||
TCP = dict(port=None, baud=None, host="10.0.0.5", tcp_port=9034)
|
||||
|
||||
|
||||
class Audit:
|
||||
def __init__(self):
|
||||
self.rows = {}
|
||||
|
||||
def begin(self, **f):
|
||||
cid = f"c{len(self.rows) + 1}"
|
||||
self.rows[cid] = dict(f, outcome="pending")
|
||||
return cid
|
||||
|
||||
def finish(self, cid, **f):
|
||||
self.rows[cid].update(f)
|
||||
|
||||
|
||||
class Cache:
|
||||
def __init__(self):
|
||||
self.dirty = []
|
||||
|
||||
def mark_config_dirty(self, key):
|
||||
self.dirty.append(key)
|
||||
|
||||
|
||||
@pytest.fixture
|
||||
def unit(monkeypatch):
|
||||
def make(fake):
|
||||
access = DeviceAccess(s4_client_factory=lambda a, **kw: fake, start_reaper=False,
|
||||
audit=Audit(), sleep=lambda s: None)
|
||||
monkeypatch.setattr(srv, "_device_access_instance", access)
|
||||
cache = Cache()
|
||||
monkeypatch.setattr(srv, "get_cache", lambda: cache)
|
||||
return cache
|
||||
return make
|
||||
|
||||
|
||||
def _post(changes, *, revision=None, dry_run=False, serial="UM20147"):
|
||||
return srv.device_settings_change(body=srv.SettingsChangeBody(changes=changes, revision=revision),
|
||||
serial=serial, dry_run=dry_run, caller="test", **TCP)
|
||||
|
||||
|
||||
def _body(resp):
|
||||
return json.loads(resp.body)
|
||||
|
||||
|
||||
def test_route_dry_run_returns_fields_and_revision(unit):
|
||||
cache = unit(FakeMicromateClient())
|
||||
resp = _post({"geo_trigger_ips": 0.3}, dry_run=True)
|
||||
body = _body(resp)
|
||||
assert resp.status_code == 200 and body["outcome"] == "dry_run"
|
||||
assert body["plan"]["fields"]["geo_trigger_ips"] == {"label": "Geophone trigger", "old": 0.5, "new": 0.3}
|
||||
assert len(body["plan"]["revision"]) == 16 and cache.dirty == []
|
||||
|
||||
|
||||
def test_route_verified_change_is_200_and_mismatch_409(unit, monkeypatch):
|
||||
fake = FakeMicromateClient()
|
||||
cache = unit(fake)
|
||||
rev = _body(_post({"geo_trigger_ips": 0.3}, dry_run=True))["plan"]["revision"]
|
||||
resp = _post({"geo_trigger_ips": 0.3}, revision=rev)
|
||||
assert resp.status_code == 200 and _body(resp)["state_after"] == "as asked"
|
||||
assert len(cache.dirty) == 1 # a by-host read must not serve stale settings
|
||||
# a unit that acks but stores something else reads back "differs": 409
|
||||
fake2 = FakeMicromateClient()
|
||||
unit(fake2)
|
||||
rev = _body(_post({"job_number": 7}, dry_run=True))["plan"]["revision"]
|
||||
real = fake2.protocol.execute
|
||||
|
||||
def wrong(plan):
|
||||
acks = real(plan)
|
||||
fake2.setup = fake2.setup[:40] + b"\x00\x08" + fake2.setup[42:]
|
||||
from micromate.setup_block import with_crc
|
||||
fake2.setup = with_crc(fake2.setup)
|
||||
return acks
|
||||
monkeypatch.setattr(fake2.protocol, "execute", wrong)
|
||||
resp = _post({"job_number": 7}, revision=rev)
|
||||
assert resp.status_code == 409 and _body(resp)["verified"] == "mismatch"
|
||||
|
||||
|
||||
def test_route_unconfirmed_carries_sent_and_audit_id(unit, monkeypatch):
|
||||
fake = FakeMicromateClient()
|
||||
unit(fake)
|
||||
rev = _body(_post({"geo_trigger_ips": 0.3}, dry_run=True))["plan"]["revision"]
|
||||
real = fake.protocol.execute
|
||||
|
||||
def then_drop(plan):
|
||||
acks = real(plan)
|
||||
fake.run_states = [0x03] # it began calling home before the read-back
|
||||
return acks
|
||||
monkeypatch.setattr(fake.protocol, "execute", then_drop)
|
||||
resp = _post({"geo_trigger_ips": 0.3}, revision=rev)
|
||||
body = _body(resp)
|
||||
assert body["sent"] == "acknowledged" and body["audit_id"]
|
||||
|
||||
|
||||
@pytest.mark.parametrize("fake_kw, match", [
|
||||
(dict(schedule_body=schedule_record(14, 0x02, "other.mmb") + bytes(264)), "other.mmb"),
|
||||
(dict(active_name="factory.MMB"), "factory setup"),
|
||||
(dict(run_states=[0x02]), "stop it first"),
|
||||
])
|
||||
def test_route_refusal_is_409_with_reason(unit, fake_kw, match):
|
||||
fake = FakeMicromateClient(**fake_kw)
|
||||
unit(fake)
|
||||
rev = "0000000000000000"
|
||||
if 0x02 not in fake.run_states: # a monitoring unit refuses the preview too
|
||||
rev = _body(_post({"geo_trigger_ips": 0.3}, dry_run=True))["plan"]["revision"]
|
||||
with pytest.raises(HTTPException) as e:
|
||||
_post({"geo_trigger_ips": 0.3}, revision=rev)
|
||||
assert e.value.status_code == 409 and match in str(e.value.detail)
|
||||
|
||||
|
||||
def test_route_stale_preview_is_409(unit):
|
||||
unit(FakeMicromateClient())
|
||||
with pytest.raises(HTTPException) as e:
|
||||
_post({"geo_trigger_ips": 0.3}, revision="0000000000000000")
|
||||
assert e.value.status_code == 409 and "preview again" in str(e.value.detail)
|
||||
|
||||
|
||||
def test_route_live_without_revision_is_422(unit):
|
||||
unit(FakeMicromateClient())
|
||||
with pytest.raises(HTTPException) as e:
|
||||
_post({"geo_trigger_ips": 0.3})
|
||||
assert e.value.status_code == 422 and "preview first" in str(e.value.detail)
|
||||
|
||||
|
||||
@pytest.mark.parametrize("route", ["device_config", "device_config_project"])
|
||||
def test_legacy_config_routes_are_gone(route, monkeypatch):
|
||||
monkeypatch.setattr(srv, "_build_client", lambda *a, **kw: pytest.fail("no client may be built"))
|
||||
resp = getattr(srv, route)()
|
||||
assert resp.status_code == 410 and "/device/settings/change" in _body(resp)["detail"]
|
||||
|
||||
|
||||
def test_settings_change_is_serial_aware():
|
||||
assert "/device/settings/change" in srv._SERIAL_AWARE_PATHS
|
||||
assert srv._device_guard("/device/settings/change", {"serial": "UM20147", "host": "h"}) is None
|
||||
@@ -0,0 +1,313 @@
|
||||
"""One settings codec for both series (phase 5): the field registry, the limits,
|
||||
the byte patching, and the read-back verdict.
|
||||
|
||||
Ground truth:
|
||||
* Series 3: Blastware's own compliance writes -- BE11529's nine on 2026-04-20
|
||||
(bridges/captures/4-20-26) and BE9441's two on 2026-10-26 -- each reproduced
|
||||
from the block before it with the fields Blastware changed.
|
||||
* Series 4: the 15 UM20147 / UM12947 keypad fixtures, pairwise.
|
||||
Limits are the units' own, from Instantel's manuals (Brian, 2026-11-03).
|
||||
"""
|
||||
from __future__ import annotations
|
||||
|
||||
import glob
|
||||
import itertools
|
||||
import os
|
||||
import re
|
||||
import struct
|
||||
import sys
|
||||
from pathlib import Path
|
||||
|
||||
import pytest
|
||||
|
||||
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
|
||||
|
||||
from micromate import setup_fields as sf # noqa: E402
|
||||
from micromate.setup_block import crc_ok # noqa: E402
|
||||
from micromate.setup_fields import ( # noqa: E402
|
||||
SettingsValueError, check_changes, editable_fields, encode_setup, field_bytes, field_values,
|
||||
revision, settings_state,
|
||||
)
|
||||
from minimateplus.framing import S3FrameParser # noqa: E402
|
||||
from minimateplus.protocol import assemble_compliance_content, is_compliance_content # noqa: E402
|
||||
from test_minimate_write_frames import WRITES, _frames, _payload # noqa: E402
|
||||
|
||||
ROOT = Path(__file__).resolve().parent.parent
|
||||
APRIL = ROOT / "bridges" / "captures" / "4-20-26"
|
||||
S4_FIX = sorted(glob.glob(str(ROOT / "tests" / "fixtures" / "micromate-setup" / "*.bin")))
|
||||
TEN26 = ROOT / "tests" / "fixtures" / "minimate-bench-10-26-26-histogram"
|
||||
|
||||
|
||||
def _s4(path) -> bytes:
|
||||
b = Path(path).read_bytes()
|
||||
return b[-2092:] if len(b) > 2092 else b
|
||||
|
||||
|
||||
def _image(frames) -> bytes:
|
||||
return b"".join(_payload(f)[16:] for f in frames if _payload(f)[2] == 0x71)
|
||||
|
||||
|
||||
def _reads(replies: bytes) -> list:
|
||||
"""Each 1A read in a reply stream, assembled (a probe reply starts each)."""
|
||||
reads, cur = [], None
|
||||
for f in S3FrameParser().feed(replies):
|
||||
if f.sub != 0xE5:
|
||||
continue
|
||||
if len(f.data) == 11:
|
||||
cur = []
|
||||
reads.append(cur)
|
||||
elif cur is not None:
|
||||
cur.append(bytes(f.data))
|
||||
return [assemble_compliance_content(r) for r in reads if r]
|
||||
|
||||
|
||||
def _april_pairs() -> list:
|
||||
"""(name, before, after) for BE11529's April writes, in time order."""
|
||||
if not APRIL.is_dir():
|
||||
return []
|
||||
files = sorted(glob.glob(str(APRIL / "**" / "raw_bw_*.bin"), recursive=True),
|
||||
key=lambda p: re.search(r"_(\d{6})_", os.path.basename(p)).group(1))
|
||||
imgs = [(os.path.basename(p), _image(_frames(Path(p).read_bytes()))) for p in files]
|
||||
imgs = [(n, i) for n, i in imgs if len(i) >= 2092]
|
||||
pairs = []
|
||||
first_name, first_img = imgs[0]
|
||||
s3 = Path(str(Path(files[0]).parent / first_name.replace("raw_bw_", "raw_s3_")))
|
||||
whole = [r for r in _reads(s3.read_bytes())] if s3.exists() else []
|
||||
whole = [r for r in whole if is_compliance_content(r)]
|
||||
if whole: # the read Blastware took before its first write
|
||||
pairs.append((first_name, whole[0], first_img))
|
||||
for (_, a), (n, b) in zip(imgs, imgs[1:]):
|
||||
pairs.append((n, a, b))
|
||||
return pairs
|
||||
|
||||
|
||||
def _ten26_pairs() -> list:
|
||||
reads = _reads((TEN26 / "unit_replies.bin").read_bytes())
|
||||
i0, i1 = _image(WRITES[0:13]), _image(WRITES[13:26])
|
||||
return [("10-26 send1", reads[0], i0), ("10-26 send2", i0, i1)]
|
||||
|
||||
|
||||
def _changes(before: bytes, after: bytes, series: int) -> dict:
|
||||
a, b = field_values(before, series), field_values(after, series)
|
||||
return {f: b[f] for f in b if b[f] != a[f]}
|
||||
|
||||
|
||||
def _with_mic(encoded: bytes, after: bytes) -> bytes:
|
||||
"""Test-only: BE9441's 16:26 write also turned the mic on ([25] bit 0x08), a
|
||||
byte v1 does not offer. Copy that one bit from Blastware's image."""
|
||||
out = bytearray(encoded)
|
||||
out[25] = (out[25] & ~0x08) | (after[25] & 0x08)
|
||||
return bytes(out)
|
||||
|
||||
|
||||
def _blastware_mic_rerender(before: bytes, after: bytes) -> bytes:
|
||||
"""Blastware's write with the unit's own mic trigger levels put back where
|
||||
Blastware re-rendered them through its dB value. Measured on BE11529's first
|
||||
write of 2026-04-20 (15:19): the unit read 0.005 and 0.01 psi (channel blocks
|
||||
3 and 7, `MicL`), Blastware wrote 0.004983 and 0.010058 -- the same levels to
|
||||
its 0.1 dB. SFM echoes the unit's bytes instead; every other byte must match."""
|
||||
out = bytearray(after)
|
||||
for k in range(8):
|
||||
o = 1708 + 48 * k
|
||||
if before[o:o + 4] != b"MicL":
|
||||
continue
|
||||
a = struct.unpack_from(">f", before, o + 30)[0]
|
||||
b = struct.unpack_from(">f", after, o + 30)[0]
|
||||
if a != b and abs(a - b) <= 0.01 * abs(a): # 0.1 dB is 1.2 % in pressure
|
||||
out[o + 30:o + 34] = before[o + 30:o + 34]
|
||||
return bytes(out)
|
||||
|
||||
|
||||
S3_PAIRS = _april_pairs() + _ten26_pairs()
|
||||
|
||||
|
||||
@pytest.mark.parametrize("name,before,after", S3_PAIRS, ids=[p[0] for p in S3_PAIRS])
|
||||
def test_s3_reproduces_every_blastware_write(name, before, after):
|
||||
out = _with_mic(encode_setup(before[:2090], 3, _changes(before, after, 3)), after)
|
||||
assert out[:2090] == _blastware_mic_rerender(before, after)[:2090]
|
||||
|
||||
|
||||
def test_the_blastware_writes_are_all_here():
|
||||
if not APRIL.is_dir():
|
||||
pytest.skip("bridges/captures is not on this machine")
|
||||
assert len(S3_PAIRS) >= 10 # 8 April pairs (+1 if its first read is whole) and 2 on 10-26
|
||||
|
||||
|
||||
def _diffs(a: bytes, b: bytes) -> set:
|
||||
return {i for i in range(2090) if a[i] != b[i]}
|
||||
|
||||
|
||||
def test_s4_fixture_pairs_reproduce():
|
||||
fb = field_bytes(4)
|
||||
covered = 0
|
||||
for pa, pb in itertools.permutations(S4_FIX, 2):
|
||||
a, b = _s4(pa), _s4(pb)
|
||||
d = _diffs(a, b)
|
||||
if not d:
|
||||
continue
|
||||
touched = {f for f, bs in fb.items() if bs & d}
|
||||
if d - set().union(*(fb[f] for f in touched)):
|
||||
continue # a byte outside the registry moved: not a field-only pair
|
||||
out = encode_setup(a, 4, {f: field_values(b, 4)[f] for f in touched})
|
||||
assert out == b, (os.path.basename(pa), os.path.basename(pb))
|
||||
covered += 1
|
||||
assert covered >= 10
|
||||
|
||||
|
||||
# ── limits (the units' own) ──────────────────────────────────────────────────
|
||||
|
||||
S3_BLOCK = _ten26_pairs()[1][2][:2090] # BE9441, 4096 sps, histogram, Normal range
|
||||
S4_BLOCK = _s4(ROOT / "tests" / "fixtures" / "micromate-setup" / "um20147_baseline.bin")
|
||||
|
||||
|
||||
def _refused(block, series, changes):
|
||||
with pytest.raises(SettingsValueError):
|
||||
check_changes(block, series, changes)
|
||||
|
||||
|
||||
def test_trigger_checked_against_the_new_range():
|
||||
_refused(S3_BLOCK, 3, {"geo_range": "sensitive", "geo_trigger_ips": 2.0})
|
||||
assert check_changes(S3_BLOCK, 3, {"geo_range": "sensitive", "geo_trigger_ips": 1.25})
|
||||
assert check_changes(S3_BLOCK, 3, {"geo_trigger_ips": 2.0})
|
||||
|
||||
|
||||
def test_limits_refuse_outside_values():
|
||||
for v in (0.004, 10.001, 0.3005):
|
||||
_refused(S4_BLOCK, 4, {"geo_trigger_ips": v})
|
||||
for v in (0, 10000):
|
||||
_refused(S4_BLOCK, 4, {"job_number": v})
|
||||
for v in (0.9, 90.1):
|
||||
_refused(S4_BLOCK, 4, {"record_time_s": v})
|
||||
assert check_changes(S4_BLOCK, 4, {"record_time_s": 90.0})
|
||||
assert check_changes(S3_BLOCK, 3, {"record_time_s": 26.0}) # 4096 sps
|
||||
_refused(S3_BLOCK, 3, {"record_time_s": 26.1})
|
||||
assert check_changes(S3_BLOCK, 3, {"record_mode": "histogram_continuous", "record_time_s": 13.0})
|
||||
_refused(S3_BLOCK, 3, {"record_mode": "histogram_continuous", "record_time_s": 13.1})
|
||||
assert check_changes(S3_BLOCK, 3, {"sample_rate": 1024, "record_time_s": 100.0}) # the new rate counts
|
||||
_refused(S3_BLOCK, 3, {"sample_rate": 8192})
|
||||
_refused(S3_BLOCK, 3, {"histogram_interval_s": 30})
|
||||
_refused(S3_BLOCK, 3, {"geo_trigger_ips": "0.3"}) # a number, not a string
|
||||
_refused(S3_BLOCK, 3, {"job_number": True})
|
||||
|
||||
|
||||
def test_field_not_offered_for_the_series():
|
||||
with pytest.raises(SettingsValueError, match="Series 4"):
|
||||
check_changes(S4_BLOCK, 4, {"geo_range": "sensitive"})
|
||||
_refused(S4_BLOCK, 4, {"no_such_field": 1})
|
||||
|
||||
|
||||
def test_the_alarm_is_writable_since_the_bench():
|
||||
# Bench 2026-11-04, BE9441: 1.0 -> 1.5 -> 1.0, each acknowledged, read back and
|
||||
# shown in the unit's own setup menu; the write moved exactly channel +39 of the
|
||||
# three geophones (the f32 at +38).
|
||||
assert sf.S3_ALARM_WRITE_MEASURED is True
|
||||
assert check_changes(S3_BLOCK, 3, {"geo_alarm_ips": 1.5}) == {"geo_alarm_ips": 1.5}
|
||||
alarm = next(d for d in editable_fields(S3_BLOCK, 3) if d["field"] == "geo_alarm_ips")
|
||||
assert alarm["readonly"] is False
|
||||
out = encode_setup(S3_BLOCK, 3, {"geo_alarm_ips": 1.5})
|
||||
assert [i for i in range(2090) if out[i] != S3_BLOCK[i] and i not in (26, 27)] == [1747, 1795, 1843]
|
||||
_refused(S4_BLOCK, 4, {"geo_alarm_ips": 1.5}) # still Series 3 only
|
||||
|
||||
|
||||
def _with_unit(block: bytes, unit: bytes) -> bytes:
|
||||
out = bytearray(block)
|
||||
for k in range(3):
|
||||
out[1708 + 48 * k + 34: 1708 + 48 * k + 38] = unit
|
||||
return bytes(out)
|
||||
|
||||
|
||||
def test_metric_unit_string_refuses_level_writes():
|
||||
_refused(_with_unit(S4_BLOCK, b"mm\x00\x00"), 4, {"geo_trigger_ips": 0.3})
|
||||
assert check_changes(_with_unit(S4_BLOCK, b"in.\x00"), 4, {"geo_trigger_ips": 0.3})
|
||||
assert check_changes(_with_unit(S4_BLOCK, b"in\x00\x00"), 4, {"geo_trigger_ips": 0.3})
|
||||
assert check_changes(_with_unit(S4_BLOCK, b"mm\x00\x00"), 4, {"job_number": 5}) # not a level
|
||||
|
||||
|
||||
def test_note_edges():
|
||||
assert check_changes(S4_BLOCK, 4, {"note_1": ""})
|
||||
assert check_changes(S4_BLOCK, 4, {"note_1": "x" * 41})
|
||||
_refused(S4_BLOCK, 4, {"note_1": "x" * 42})
|
||||
_refused(S4_BLOCK, 4, {"note_1": "café"})
|
||||
_refused(S4_BLOCK, 4, {"note_1": "tab\there"})
|
||||
out = encode_setup(S4_BLOCK, 4, {"note_1": ""})
|
||||
assert out[144:186] == bytes(42)
|
||||
|
||||
|
||||
def test_note_labels_are_never_written():
|
||||
out = encode_setup(S4_BLOCK, 4, {"note_2": "Loc 9 - North wall"})
|
||||
assert _diffs(S4_BLOCK, out) <= set(range(208, 250))
|
||||
assert out[186:208] == S4_BLOCK[186:208]
|
||||
|
||||
|
||||
def test_bit_fields_keep_unknown_bits():
|
||||
b = bytearray(S4_BLOCK)
|
||||
b[39] = 0x81
|
||||
assert encode_setup(bytes(b), 4, {"job_number_shown": True})[39] == 0x83
|
||||
b[39] = 0x83
|
||||
assert encode_setup(bytes(b), 4, {"job_number_shown": False})[39] == 0x81
|
||||
|
||||
|
||||
def test_s3_fixed_bytes():
|
||||
b = bytearray(S3_BLOCK)
|
||||
b[26:28] = b"\x01\x7f"
|
||||
assert encode_setup(bytes(b), 3, {"job_number": 7})[26:28] == b"\x00\x00"
|
||||
|
||||
|
||||
def test_s4_encode_recomputes_the_crc():
|
||||
out = encode_setup(S4_BLOCK, 4, {"job_number": 7})
|
||||
assert crc_ok(out) and out[40:42] == (7).to_bytes(2, "big")
|
||||
|
||||
|
||||
def test_f32_values_read_back_as_asked():
|
||||
written = encode_setup(S4_BLOCK, 4, {"geo_trigger_ips": 0.3})
|
||||
assert struct.unpack_from(">f", written, 1708 + 30)[0] != 0.3 # f32: 0.30000001192
|
||||
assert field_values(written, 4)["geo_trigger_ips"] == 0.3
|
||||
assert settings_state(S4_BLOCK, written, written, series=4) == "as asked"
|
||||
|
||||
|
||||
def test_settings_state():
|
||||
written = encode_setup(S4_BLOCK, 4, {"job_number": 7})
|
||||
assert settings_state(S4_BLOCK, written, S4_BLOCK, series=4) == "unchanged"
|
||||
other = encode_setup(S4_BLOCK, 4, {"job_number": 8})
|
||||
assert settings_state(S4_BLOCK, written, other, series=4) == "differs"
|
||||
bad = bytearray(written)
|
||||
bad[2091] ^= 0xFF
|
||||
assert settings_state(S4_BLOCK, written, bytes(bad), series=4) == "differs"
|
||||
# Series 3: a block that differs from its image only in Blastware's fixed bytes is as asked
|
||||
before = bytearray(S3_BLOCK)
|
||||
before[26:28] = b"\x01\x7f"
|
||||
before = bytes(before)
|
||||
assert settings_state(before, encode_setup(before, 3, {}), before, series=3) == "as asked"
|
||||
|
||||
|
||||
def test_revision_is_stable_and_content_sensitive():
|
||||
r = revision([S4_BLOCK, b"name"])
|
||||
assert r == revision([S4_BLOCK, b"name"]) and len(r) == 16
|
||||
assert r != revision([S4_BLOCK, b"nams"])
|
||||
|
||||
|
||||
def test_editable_fields_describe_both_series():
|
||||
s3 = {d["field"]: d for d in editable_fields(S3_BLOCK, 3)}
|
||||
s4 = {d["field"]: d for d in editable_fields(S4_BLOCK, 4)}
|
||||
assert {"geo_range", "geo_alarm_ips"} <= set(s3) and not {"geo_range", "geo_alarm_ips"} & set(s4)
|
||||
assert s3["record_mode"]["value"] == "histogram" and s3["sample_rate"]["value"] == 4096
|
||||
assert s3["note_1"]["label"] == "Project" and s3["note_1"]["maxlength"] == 41
|
||||
assert s4["note_1"]["label"] == "Location"
|
||||
assert s4["record_time_s"]["max"] == 90.0 and s3["record_time_s"]["max"] == 26.0
|
||||
|
||||
|
||||
# Final review #2: the limits hold on the block that would result, not only on the
|
||||
# fields in the request -- a one-field change must not leave the unit over them.
|
||||
def test_limits_hold_on_the_resulting_block():
|
||||
hot = encode_setup(S3_BLOCK, 3, {"geo_trigger_ips": 2.0})
|
||||
_refused(hot, 3, {"geo_range": "sensitive"}) # trigger 2.0 > 1.25
|
||||
alarm = bytearray(S3_BLOCK)
|
||||
struct.pack_into(">f", alarm, 1708 + 38, 2.0)
|
||||
for k in (1, 2):
|
||||
struct.pack_into(">f", alarm, 1708 + 48 * k + 38, 2.0)
|
||||
_refused(bytes(alarm), 3, {"geo_range": "sensitive"}) # alarm 2.0 > 1.25
|
||||
_refused(S3_BLOCK, 3, {"record_mode": "histogram_continuous"}) # it holds 20 s; combo max 13
|
||||
slow = encode_setup(S3_BLOCK, 3, {"sample_rate": 1024, "record_time_s": 100.0})
|
||||
_refused(slow, 3, {"sample_rate": 4096}) # 100 s > 26 at 4096
|
||||
assert check_changes(S3_BLOCK, 3, {"note_1": "x"}) # nothing limit-related touched
|
||||
assert check_changes(hot, 3, {"geo_range": "normal"}) # 2.0 <= 10
|
||||
@@ -29,7 +29,8 @@ pytestmark = pytest.mark.skipif(NODE is None, reason="node is not installed; the
|
||||
|
||||
EXPORTS = ["seriesFromSerial", "unitQuery", "deviceUrl", "confirmedSeries", "controlsFor", "eventView", "settingsRows", "perIndexLive", "escapeHtml",
|
||||
"changeSummary", "downloadSummary", "firmwareLabel", "deviceErrorText", "changeErrorText", "serialPanes",
|
||||
"callHomeRows"]
|
||||
"callHomeRows", "settingsFormFields", "settingsChanges",
|
||||
"settingsPreviewRows", "settingsBlockedText", "settingsResultRows"]
|
||||
|
||||
|
||||
def _block() -> str:
|
||||
@@ -77,7 +78,8 @@ def test_device_url():
|
||||
["deviceUrl", ["start", S4]], ["deviceUrl", ["stop", S3]],
|
||||
["deviceUrl", ["erase", S3]], ["deviceUrl", ["call_home_read", BLANK]],
|
||||
["deviceUrl", ["config_write", S3]], ["deviceUrl", ["nonsense", S3]],
|
||||
["deviceUrl", ["download", BLANK, {"event_id": "x"}]], ["deviceUrl", ["hangup", BLANK]])
|
||||
["deviceUrl", ["download", BLANK, {"event_id": "x"}]], ["deviceUrl", ["hangup", BLANK]],
|
||||
["deviceUrl", ["settings_change", S4, {"dry_run": "true"}]], ["deviceUrl", ["settings_change", BLANK]])
|
||||
assert r[0] == {"method": "GET", "path": "/device/info?serial=BE9441&host=h&tcp_port=9034"}
|
||||
assert r[1] == {"method": "GET", "path": "/device/monitor/status?serial=UM20147&host=h&tcp_port=9034"}
|
||||
assert r[2] == {"method": "POST", "path": "/device/hangup?host=h&tcp_port=9034"}
|
||||
@@ -88,9 +90,12 @@ def test_device_url():
|
||||
assert r[6] == {"method": "POST", "path": "/device/monitor/stop?serial=BE9441&host=h&tcp_port=9034"}
|
||||
assert r[7] == {"method": "POST", "path": "/device/events/erase?serial=BE9441&host=h&tcp_port=9034"}
|
||||
assert r[8] == {"method": "GET", "path": "/device/call_home?host=h&tcp_port=9034"}
|
||||
assert r[9] == {"method": "POST", "path": "/device/config?serial=BE9441&host=h&tcp_port=9034"}
|
||||
assert "throws" in r[9] # /device/config is retired (phase 5)
|
||||
assert "throws" in r[10]
|
||||
assert r[11] is None and r[12] is None
|
||||
assert r[13] == {"method": "POST", "path": "/device/settings/change?serial=UM20147&host=h&tcp_port=9034"
|
||||
"&dry_run=true"}
|
||||
assert r[14] is None # by serial only
|
||||
|
||||
|
||||
def _with(unit, confirmed):
|
||||
@@ -126,13 +131,62 @@ def test_controls_a_legacy_identify_confirms_without_a_typed_serial():
|
||||
assert s == 3 and c["diagnostics"] is True and c["startStop"] is False # start/stop needs a serial
|
||||
|
||||
|
||||
def test_controls_config_waits_for_phase_5_and_the_legacy_call_home_form_stays_off():
|
||||
def test_controls_config_write_is_by_serial_for_both_series():
|
||||
for unit in (_with(S3, {"serial": "BE9441", "series": 3}), _with(S4, {"serial": "UM20147", "series": 4})):
|
||||
c = run(["controlsFor", [unit]])[0]
|
||||
assert c["configWrite"] is False and c["callHomeWrite"] is False
|
||||
assert c["reasons"] == {"configWrite": "Coming in phase 5 (#46)",
|
||||
assert c["configWrite"] is True and c["callHomeWrite"] is False
|
||||
assert c["reasons"] == {"configWrite": "By serial only: Preview, then Send (audited).",
|
||||
"callHomeWrite": "By serial: use Call-home On / Off (audited). Other call-home "
|
||||
"fields wait for the THOR round."}
|
||||
c = run(["controlsFor", [_with(BLANK, {"serial": "BE9441", "series": 3})]])[0]
|
||||
assert c["configWrite"] is False # by host: the legacy form is read-only
|
||||
|
||||
|
||||
EDITABLE = [
|
||||
{"field": "record_mode", "label": "Record mode", "kind": "choice", "value": "histogram",
|
||||
"choices": [{"value": "histogram", "label": "Histogram"}, {"value": "waveform", "label": "Waveform"}]},
|
||||
{"field": "sample_rate", "label": "Sample rate", "kind": "choice", "value": 1024, "unit": "sps",
|
||||
"choices": [{"value": 1024, "label": "1024 sps"}, {"value": 4096, "label": "4096 sps"}]},
|
||||
{"field": "geo_trigger_ips", "label": "Geophone trigger", "kind": "number", "value": 0.3,
|
||||
"unit": "in/s", "min": 0.005, "max": 10.0, "step": 0.001},
|
||||
{"field": "geo_alarm_ips", "label": "Geophone alarm", "kind": "number", "value": 1.0, "readonly": True},
|
||||
{"field": "job_number_shown", "label": "Job number on report", "kind": "bool", "value": False},
|
||||
{"field": "note_1", "label": "Project", "kind": "text", "value": "Bridge", "maxlength": 41},
|
||||
]
|
||||
|
||||
|
||||
def test_settings_form_fields_come_from_the_servers_list_in_order():
|
||||
(f,) = run(["settingsFormFields", [{"detail": {"editable": EDITABLE}}]])
|
||||
assert [x["field"] for x in f] == [e["field"] for e in EDITABLE]
|
||||
assert f[2] == EDITABLE[2] and f[3]["readonly"] is True
|
||||
assert run(["settingsFormFields", [{"detail": {}}]]) == [[]]
|
||||
|
||||
|
||||
def test_settings_changes_are_only_what_differs():
|
||||
same = {"record_mode": "histogram", "sample_rate": "1024", "geo_trigger_ips": "0.30",
|
||||
"geo_alarm_ips": "2.0", "job_number_shown": False, "note_1": "Bridge"}
|
||||
edited = {**same, "sample_rate": "4096", "geo_trigger_ips": "0.25", "job_number_shown": True,
|
||||
"note_1": "Bridge 2"}
|
||||
a, b = run(["settingsChanges", [EDITABLE, same]], ["settingsChanges", [EDITABLE, edited]])
|
||||
assert a == {} # 0.30 == 0.3; the read-only alarm is ignored
|
||||
assert b == {"sample_rate": 4096, "geo_trigger_ips": 0.25, "job_number_shown": True, "note_1": "Bridge 2"}
|
||||
|
||||
|
||||
PREVIEW = {"outcome": "dry_run", "plan": {
|
||||
"fields": {"geo_trigger_ips": {"label": "Geophone trigger", "old": 0.5, "new": 0.3},
|
||||
"note_1": {"label": "Project", "old": "", "new": "Bridge"}},
|
||||
"blocked": ["this unit's schedule loads other.mmb at 07:00, which would replace this change"],
|
||||
"revision": "0123456789abcdef"}}
|
||||
RESULT = {"outcome": "sent", "verified": "ok", "detail": {"snapshot": {"fields": {
|
||||
"geo_trigger_ips": {"label": "Geophone trigger", "old": 0.5, "new": 0.3, "now": 0.3}}}}}
|
||||
|
||||
|
||||
def test_settings_preview_result_and_blocked_text():
|
||||
rows, blocked, none, result = run(["settingsPreviewRows", [PREVIEW]], ["settingsBlockedText", [PREVIEW]],
|
||||
["settingsBlockedText", [RESULT]], ["settingsResultRows", [RESULT]])
|
||||
assert rows == [["Geophone trigger", 0.5, 0.3], ["Project", "—", "Bridge"]]
|
||||
assert "other.mmb" in blocked and none == ""
|
||||
assert result == [["Geophone trigger", 0.5, 0.3, 0.3]]
|
||||
|
||||
|
||||
def test_change_summary():
|
||||
@@ -334,3 +388,14 @@ def test_call_home_rows_say_why_a_switch_did_not_read():
|
||||
r = run(["callHomeRows", [{"enabled": None, "dial_string": None, "series": 3,
|
||||
"detail": {"byte5": "0x6E", "reason": "not readable while monitoring -- stop it first"}}]])
|
||||
assert r[0][0] == ["Call-home", "not readable while monitoring -- stop it first"]
|
||||
|
||||
|
||||
def test_change_summary_for_settings_says_it_plainly():
|
||||
base = {"action": "change settings", "audit_id": "cb540970-5e17", "state_before": "unchanged"}
|
||||
ok, skip, mism = run(
|
||||
["changeSummary", [{**base, "outcome": "sent", "verified": "ok", "state_after": "as asked"}]],
|
||||
["changeSummary", [{**base, "outcome": "skipped", "verified": "not_checked", "state_before": "as asked"}]],
|
||||
["changeSummary", [{**base, "outcome": "failed", "verified": "mismatch", "state_after": "differs"}]])
|
||||
assert ok == "change settings: confirmed — the unit holds what was sent (audit cb540970)"
|
||||
assert skip == "change settings: the unit already holds these — nothing sent"
|
||||
assert "unit reads differs" in mism and "cb540970" in mism
|
||||
@@ -57,3 +57,17 @@ def test_the_page_scripts_are_served_from_static(name):
|
||||
|
||||
def test_a_missing_static_file_is_a_404():
|
||||
assert _get("/static/nope.js")[0] == 404
|
||||
|
||||
|
||||
def test_the_config_write_is_the_audited_preview_and_send():
|
||||
# Phase 5: the legacy by-host "Write to Device" is gone; the serial-mode edit
|
||||
# form's Preview and Send are wired from sfm_webapp.js, not inline handlers.
|
||||
html = PAGE.read_text()
|
||||
assert 'id="cfg-write-btn"' not in html
|
||||
for el in ("cfg-edit", "cfg-preview-btn", "cfg-send-btn", "cfg-preview", "cfg-result"):
|
||||
tag = re.search(r'<[^>]*id="%s"[^>]*>' % el, html)
|
||||
assert tag is not None and "onclick" not in tag.group(0), el
|
||||
js = (PAGE.parent / "static" / "sfm_webapp.js").read_text()
|
||||
assert "config_write" not in js and "function writeConfig" not in js
|
||||
assert "getElementById('cfg-preview-btn').addEventListener" in js
|
||||
assert "getElementById('cfg-send-btn').addEventListener" in js
|
||||
Reference in new issue
Block a user