62 Commits
Author SHA1 Message Date
serversdown 30bfdd6eff Merge pull request 'Release v0.34.0 — Series-4 parity, and most of Blastware's report from the event file alone' (#59) from dev into main
Reviewed-on: #59
2026-11-04 18:19:22 -05:00
serversdownandClaude Opus 5.5 c9f41deadd chore(release): v0.34.0 — Series-4 parity, and most of Blastware's report from the event file alone
- CHANGELOG: Unreleased -> v0.34.0 — 2026-11-04, with the release theme
  and a Migration section (schema re-key + overnight backfill that moves
  every Series-3 histogram time by one second; rehearsed twice on a copy
  of prod's 2026-09-30 snapshot).
- pyproject.toml, CLAUDE.md, README: 0.34.0 (README gains its status
  entry).
- TOOL_VERSION 0.34.0: the codec changed, so the backfill regenerates.

Verified on dev before this commit: the full decode checker matches
pre-parity dev on every verdict of all 70,112 DL2 events (47 of 88
fields), group D part 1 ran clean on its branch, and the suite has only
the 16 known failures (1,566 passed).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-04 17:58:54 -05:00
serversdownandClaude Opus 5.5 9f3434ff2b docs(changelog): Unreleased -- time of peak, vector-sum time and peak acceleration
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-04 17:56:58 -05:00
serversdownandClaude Opus 5.5 401d83dc2c merge: a waveform's time of peak, vector-sum time and peak acceleration (group D, part 1)
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-04 17:54:56 -05:00
serversdownandClaude Opus 5.5 75a1d135ee docs(changelog): Unreleased -- Series-4 parity in SFM (phases 1-5)
Everything by serial for both series, the audited changes (start/stop,
call-home, settings), the MiniMate wire fixes (#46, the 64 KB page, the
settings read as content), the legacy config write retired, the benches.
Operational: additive schema only (device_commands), no TOOL_VERSION bump,
no backfill from this branch.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-04 16:29:07 -05:00
serversdownandClaude Opus 5.5 5b342b4d7d merge: feat/series4-sfm-parity -- Series-4 parity in SFM, phases 1-5
Everything by serial for both series (identify, status, settings, events,
download, start/stop, call-home on/off, settings change), live downloads
stored as the watcher stores them, the legacy config write retired.
Phase 4 benched 2026-11-03, phase 5 benched 2026-11-04 on BE9441 and
UM20147.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-04 16:26:45 -05:00
serversdownandClaude Opus 5.5 3564c4a744 docs: phase 5 benched on both series (2026-11-04)
Both protocol references, the spec's bench section and CLAUDE.md record
the bench: every settings change acknowledged, read back and confirmed on
the unit's screen, both units restored byte for byte; the escaped-
checksum stray byte (fixed); a MiniMate's open setup menu writes its
whole-block copy back on Cancel or Save, losing a remote change; the
alarm write at channel +38; [26:28] re-set by the unit while monitoring;
the first Micromate setup push with the unit's CRC equal to SFM's; the
Micromate scheduler switch in none of the blocks SFM reads.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-04 16:16:40 -05:00
serversdownandClaude Opus 5.5 c790e20116 fix: bench follow-ups -- the setup-menu warning, observed call-home values, waveform read
From the 2026-11-04 bench:
- A MiniMate settings preview warns that a change is lost if someone is in
  the unit's setup menu: a write sent with the menu open was acknowledged
  and read back, then lost on Cancel or Save -- the menu writes its own
  copy of the whole block back (measured both ways on BE9441).
- The two bytes after the MiniMate settings block went out as 00 00 and
  the unit took them; the preview note says so instead of 'unmeasured'.
- A Micromate call-home plan no longer warns about 0x00 / 0x01: UM20147
  took both, each way, on 11-03 and 11-04, matching its menu.
- read_waveform_data_raw drops the escaped-checksum's stray 0x10, as the
  settings read does (it failed closed: the write's block check refused
  203 bytes).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-04 16:15:28 -05:00
serversdownandClaude Opus 5.5 55c7b7b5ae feat(codec): the MiniMate alarm level is writable (benched 2026-11-04)
S3_ALARM_WRITE_MEASURED = True.  At the bench on BE9441, with Brian's go,
the alarm went 1.0 -> 1.5 -> 1.0 in/s: each write acknowledged, read back
as sent, and shown in the unit's own setup menu.  The write moved exactly
channel +39 of the three geophone blocks (the f32 at +38), where the
event files put it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-04 16:12:58 -05:00
serversdownandClaude Opus 5.5 09f34c2c85 fix(decode): Blastware's g for peak acceleration, fitted to every DL2 value
Every printed acceleration in DL2 bounds Blastware's g; together they
leave [386.2236, 386.2240] in/s^2, and 386.2238 fits 19,475 / 19,479
values.  The other 4 are one odd file (O117I1NK.R70W, whose peak times
are also off) and one sample mismatch.  That is 9.81 m/s^2 (386.2205,
19,423) plus an unexplained offset, as with the mic's fitted dB offset.
The 59 values 9.81 left were all one last digit high.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-04 15:47:13 -05:00
serversdownandClaude Opus 5.5 233289d029 feat(decode): a waveform's time of peak, vector-sum time and peak acceleration
Group D, part 1, measured on 400 DL2 waveforms (2026-11-04):
- time of peak = (first peak sample - pre-trigger samples) / sample
  rate, per channel including the mic: 1,197 / 1,197 geophone values
- the vector sum's time, the same on sqrt(T^2 + V^2 + L^2): 398 / 399
- peak acceleration = the largest |v[i+1] - v[i]| x sample rate / g,
  with Blastware's g = 9.81 m/s^2: 1,190 / 1,197 (the standard 9.80665
  gives 1,073).  Blastware's manuals: 'subtracts two velocity readings
  and divides the result by the elapsed time between them'.

PeakValues gains *_time_of_peak, pvs_time and *_peak_accel_g, filled
for waveforms only.  The checker reports them.  Displacement (84% with
the manuals' half-cycle integral) and ZC frequency (46%) are not shipped
yet -- Blastware does something more there.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-04 15:19:53 -05:00
serversdownandClaude Opus 5.5 9992b25fde fix(s3): a settings read takes exactly what each frame was asked for
Bench 2026-11-04, BE9441 live: frame B of a 1A read arrived one byte long,
ending in a lone 0x10.  When a frame's checksum byte is itself escaped
(02 / 03 / 04, about one frame in 85) the parser keeps the escape's 0x10
and strips only the byte after it.  The 12 recorded reads never hit it,
so the assembled block was 2,091 bytes and SFM refused it as 'monitoring'.
read_compliance_content now passes the lengths it asked for (1024, 1024,
42) and that one stray byte is dropped; any other leftover still fails
is_compliance_content.  The trimmed read decodes exactly as the old
decoder read the same reply.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-04 13:11:32 -05:00
serversdownandClaude Opus 5.5 2d237be5ef fix(ingest): a live download is held to its record type (#51)
Since #51 a waveform and a histogram recorded in the same second are two
events (UNIQUE(serial, timestamp, record_type)).  persist_download's
'already stored?' checks matched any row at the second and any row under
the letterless Blastware name both twins share, so a live download of
one twin was skipped as stored.  Both checks now hold to the download's
own type, read from its file (STRT[18]; IDFW / IDFH); an untyped row at
that second, or a download whose type does not read, still counts as
stored.  find_event_by_blastware_name takes an optional record_type.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-04 12:34:46 -05:00
serversdownandClaude Opus 5.5 f24913189b merge: dev 9b458b5 into the parity branch (group A/B, #51 histogram timing)
Brings the checker's file-only decode work onto the parity branch so the
phase-5 bench runs on the code that will ship.  One conflict, the CRLF
Series-III reference changelog: both kept, phase 5's row numbered
'2026-11-03 (5)' above dev's (4)/(3)/(2).  test_event_ingest's live-
histogram dedup test asserted the stored row sits a second off the 0C
time -- the #51 bug, fixed on dev -- so its premise now reads the event's
own second; the dedup it tests still holds.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-04 12:31:21 -05:00
serversdownandClaude Opus 5.5 9b458b5d92 docs(changelog): Unreleased -- histogram timing in the protocol reference
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-04 12:19:52 -05:00
serversdownandClaude Opus 5.5 1f8494dbc4 merge: histogram timing in the protocol reference (D.6.10), and the unit + time + type key
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-04 12:19:41 -05:00
serversdownandClaude Opus 5.5 d4cfb07fce docs: histogram timing from its own event record (D.6.10), and the unit + time + type key
The reference gains D.6.10: the histogram's embedded event record (lead
00 28 05 00, source 04 00, marker fe f5, start, stop) and the interval
and peak-time rules, with 'histograms stay on ts1' retracted in place.
CLAUDE.md 'Where things stand' records the new events key -- any lookup
by event needs the type -- and 47 of 88; the README roadmap follows.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-04 12:19:38 -05:00
serversdownandClaude Opus 5.5 d75dc6f5f1 docs(changelog): Unreleased -- #51, unit + time + type and Blastware's histogram times
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-04 12:18:20 -05:00
serversdownandClaude Opus 5.5 074c98823f merge: events are identified by unit + time + type, and histograms take Blastware's times (#51)
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-04 12:17:30 -05:00
serversdownandClaude Opus 5.5 08d0a6c0d4 fix(settings): final-review fixes -- revision, resulting limits, logical writes
From the whole-branch review of phase 5:
- The preview's revision now covers the changes asked for, so a live
  change must be exactly what was previewed (any API caller, not only the
  page).  It covers what the preview showed -- the settings block (and a
  Micromate's setup name) -- not the blocks a write only echoes, which are
  re-read at send and sent as read (a MiniMate's trigger block byte 5
  differs by session, #46).
- The units' limits hold on the block that would result: a range, rate or
  mode change alone can no longer leave a held trigger, alarm or record
  time over them.
- Every MiniMate block read is logical, so push_config_raw no longer
  unescapes again (a job number of 4098, 10 02, was refused at Send); the
  preview runs the write's own block check, so a block it would refuse is
  shown as blocked.
- A MiniMate's monitoring refusal says a stop makes it call in (spec).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 22:10:49 -05:00
serversdownandClaude Opus 5.5 385716d8e1 feat(webapp): edit a unit's settings by serial: preview, send, read back
The Config tab by serial is now the unit's edit form, headed 'On the
unit <serial> -- read HH:MM' and built from the server's editable
fields.  Preview runs a dry run and shows old -> new, notes and anything
that blocks the change; Send (confirm) sends exactly what was previewed,
with its revision, then shows what the unit now holds and re-reads it.
An edit after a preview disables Send until the next preview.  The
by-host form loses its write button; the read stays.  Logic in
device_routing.js (Node-tested), glue in sfm_webapp.js, no inline JS.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:57:17 -05:00
serversdownandClaude Opus 5.5 e8eabee4a2 feat(sfm): POST /device/settings/change; retire the legacy config write
DeviceAccess.change_settings refuses before any I/O a request with no
changes, a live change without its preview's revision, or no audit log,
then dispatches the series' change (never retried).  The route returns
the preview (fields old -> new, warnings, blocked, revision) or the
result (fields old/new/now), statuses as the other changes, and marks
the cached by-host config dirty after a live change.

/device/config and /device/config/project now answer 410 with a pointer.
Deleted with them: MiniMateClient.apply_config / set_project_info and
the raw-offset _encode_compliance_config (#46 found it wrong), the
lab script poc_set_project.py and experiments.py's EXP6, both of which
wrote a live unit through it.  Git keeps them.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:51:20 -05:00
serversdownandClaude Opus 5.5 66bb29b9d4 feat(s3): change a MiniMate's settings by serial on the shared codec
Series3Adapter.settings reads the 1A block assembled into its 2,090
logical bytes and decodes it with micromate.setup_fields (a monitoring
unit's device-info answer is refused with 'stop monitoring first').
change_settings runs the shared change core: read the four settings
blocks, patch the settings block's fields, send Blastware's sequence
through push_config_raw with the event index, trigger and waveform blocks
as read, re-read.  Refused before sending: monitoring, a value the unit
does not allow, a stale preview.  push_config_raw's pre-check now raises
ImageRefused, so a refused image is audited as nothing sent.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:46:50 -05:00
serversdownandClaude Opus 5.5 c082f72d62 feat(s4): change a Micromate's settings by serial, audited, schedule-checked
s4_change_settings runs the shared change core with a read-back verdict
for its state (as asked / unchanged / differs).  It reads the active
setup's name (unstripped), the preferences, trigger and setup blocks and
the schedule; patches the setup through micromate.setup_fields; sends
THOR's setup push (0xDA 68 73 82 83 71 72, now enableable) once; reads
the setup back.  Refused before sending: a monitoring unit, a value the
unit does not allow (422), a stale preview (SettingsChanged, 409), and --
shown as 'blocked' in the preview -- the factory setup, a schedule that
loads another setup, an unreadable schedule, or a block SFM has not seen
(ChangeRefused, 409).  s4_settings carries the editable fields.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:43:03 -05:00
serversdownandClaude Opus 5.5 d0335dbbbd feat(micromate): read the schedule file (read-only)
MicromateProtocol.read_file: 0x94 + path, then 0x48 pages to an
all-zero reply -- THOR's frames byte for byte (UM12947, 2026-09-24),
including params[3] = 1 on 0x94 and params[7] = 1 on the first 0x48.
micromate.schedule parses the 260-byte records (two- and five-entry
schedules from THOR's captures) and names the scheduled starts that
would load a setup other than the active one, ignoring case.  The
client gains the raw (unstripped) active-setup name and the prefs /
trigger / setup content reads a setup push sends back.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:37:30 -05:00
serversdownandClaude Opus 5.5 9cfa82117b feat(decode): histogram interval times and peak times (#51 group C)
With the start right, the rest of Blastware's histogram timing follows,
measured on a 2,000-histogram DL2 sample:
- each interval's printed time is its end, start + (i + 1) x interval,
  capped at the stop: 2,308,524 / 2,308,524 rows
  (event_file_io.interval_times)
- each of Tran / Vert / Long / PVS / MicL's peak date and time is that of
  the interval holding its first maximum: 2,000 / 2,000 each.
The checker compares intervals.Time and the ten peak date/time fields.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 21:35:54 -05:00
serversdownandClaude Opus 5.5 a9bb9f08c0 fix(decode): a histogram's start and stop come from its own event record (#51)
The footer's start runs a second early on 97% of histograms.  Each
histogram carries an event record like a waveform's -- lead 00 28 05 00,
source 04 00, marker fe f5, then start and stop -- and it holds
Blastware's Histogram Start and Stop on 63,490 / 63,490 DL2 histograms.
On all 63,500 there is exactly one, its start 0 or 1 s after the
footer's and its stop 0 or 1 s before; that is the validation rule.
Without a validated record the footer's start stands, as a decode
problem.

Ships with the unit + time + type key (ea2dfc2), without which a
waveform and its histogram at the same second would collide.  Three
tests that pinned the old footer start (one said 'for now', pointing at
#51) now pin the record's, which equals the file's Blastware name.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 21:33:32 -05:00
serversdownandClaude Opus 5.5 5ba72740dd feat(codec): one settings codec for both series, on the shared layout
micromate/setup_fields.py: the fields an operator can change (record
mode, sample rate, interval, record time, geophone trigger, Series 3's
range and -- read-only until benched -- alarm, job number and its report
flag, the four notes by slot), the units' own limits from Instantel's
manuals, field-only byte patching (bit fields bit by bit; Series 3's
[26:28] as Blastware writes it; Series 4's CRC recomputed), the
read-back verdict compared by bytes, and the preview revision.

All 11 Blastware compliance writes reproduce from the block before them
(BE11529's first also shows Blastware re-rendering two mic levels
through its dB value; SFM echoes the unit's bytes); Series 4 keypad
fixtures reproduce pairwise.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:33:01 -05:00
serversdownandClaude Opus 5.5 e24e77bfd0 test: the estimate guard's neighbour is an event of the same type (#51)
Under the unit + time + type key, the test's untyped neighbour no longer
shared the imported waveform's key, so the waveform was stored as its
own row -- the neighbour untouched, which is what the test's name asks.
The guard's job is an estimate landing on another waveform's second, so
the neighbour is now a waveform.  A companion test pins the case the new
key allows: an estimate beside a histogram at its second is stored
alongside it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 21:30:51 -05:00
serversdownandClaude Opus 5.5 ea2dfc21b7 feat(db): events are identified by unit + time + type (#51)
The events table was UNIQUE(serial, timestamp): one event per unit per
second.  A unit records a waveform and a histogram in the same second
legitimately -- 209 times in prod's 2026-09-30 store once histograms
carry Blastware's start -- so the key is now (serial, timestamp,
record_type).  Agreed with Brian 2026-11-03.

- Migration 3 rebuilds the table from its own current definition with
  only the key swapped, in one transaction: every column, row and id is
  kept (Terra-View reads rows by id) and the indexes are recreated.
  Migration 1's check no longer mistakes the new key for a missing one.
- The upsert, the estimate guard and the restamp match on the type too.
  The restamp also re-types a file's own row in place: before v0.33.0 a
  row's type came from the filename, and a re-import under the file's
  own type must not add a second row.
- An untyped event still refreshes the untyped row at its second (a
  UNIQUE key treats NULLs as distinct).
- scripts/repair_unknown_serials.py checks the new key.

No time changes yet: that is the next commit, and they ship together.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 21:29:46 -05:00
serversdownandClaude Opus 5.5 1bb15573fc feat(s3): assemble a settings read into the 2,090-byte block
Unescape each 1A data frame, take data[11:], drop the one non-content
byte that starts every frame but the last: 2,090 bytes headed by
N = 2090, Series IV's 0x1A layout.  Measured on BE9441's 10-26
recording (12 reads, both frame patterns); the read after each
Blastware write equals the image written.  read_compliance_content is
strict (a missing frame raises) and unjudged (a monitoring unit's
device-info answer comes back for the caller to recognise).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:28:04 -05:00
serversdownandClaude Opus 5.5 e3a77e421d docs(spec,plan): phase 5 -- the units' own limits, from Instantel's manuals
Brian: use the actual unit limits, not what has been used in the past.
Trigger 0.005-10 in/s in 0.001 steps (capped by the range), record time
1-90 s (Micromate) or the MiniMate manual's 1 MB table by sample rate
(13 s in Histogram Combo), job number 1-9999.  The read-back reports any
value a unit does not take.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 19:30:07 -05:00
serversdownandClaude Opus 5.5 71609e71ab docs(plan): phase 5 -- changing a unit's settings by serial
Seven tasks: the Series 3 read assembly, one settings codec for both
series, the Micromate schedule read, each series' audited change, the
route (and the legacy write retired), and the page.  Spans measured
from 75,958 Blastware reports.  Bench after the final review, Brian's
go per send.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 18:51:53 -05:00
serversdownandClaude Opus 5.5 dba891d504 docs(spec): phase 5 -- the Micromate schedule check; work hours is next
A scheduled start loads the setup it names, so a change to another
setup would be undone at the next start: read schedule.dat and refuse
that case.  Configurable work-hours recording, without THOR's scheduler
or setup files, is the agreed next project.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 18:35:29 -05:00
serversdownandClaude Opus 5.5 e8242aaadc docs(changelog): Unreleased -- group B in the protocol reference
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 18:30:08 -05:00
serversdownandClaude Opus 5.5 19719bdd96 merge: group B in the protocol reference (D.6.9), #50 retracted
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 18:29:54 -05:00
serversdownandClaude Opus 5.5 2c4ae8c4ef docs: group B in the protocol reference (D.6.9), #50 retracted
Interval size (k - 40), the stop (footer ts2), frequency = (sample rate
/ 2) / half-period with Blastware's words for N/A, >100 / >200 and
<1.0, and each interval's vector sum with its OORANGE rule.  The old
fixed-512 frequency formula is retracted in place.  CLAUDE.md and the
README roadmap follow: 34 of 88.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 18:29:53 -05:00
serversdownandClaude Opus 5.5 42933f76df docs(changelog): Unreleased -- histogram interval detail, #50
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 18:29:00 -05:00
serversdownandClaude Opus 5.5 31231d7e81 merge: a histogram's interval detail -- frequencies (#50), vector sums, interval size, stop (group B)
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 18:28:27 -05:00
serversdownandClaude Opus 5.5 0238e4d3f3 docs(spec): phase 5 -- changing a unit's settings by serial
Brian's intent (UM6047's trigger, notes typos, the backup unit), the
flow, the first-version fields, and what is measured: Series 3's
compliance block has Series 4's 0x1A layout; a whole 1A read assembles
to the 2,090 bytes Blastware writes back (exact on both 10-26 writes);
Blastware writes 00 00 at [26:28] and a per-unit constant after the
block.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 18:12:14 -05:00
serversdownandClaude Opus 5.5 13f2769736 feat(decode_check): an OORANGE interval vector sum is saturation
Blastware prints OORANGE for an interval's vector sum when it exceeds
the range in an interval where Blastware also clamped a channel: 17 / 17
DL2 cells, SFM's sum 10.01 .. 17.33 in/s (sqrt 3 x 10.005).  The
saturation carve-out now covers intervals.Geo PVS in/s with that rule,
per interval, as it already did for PeakVectorSum.  The 4 other cells
left mismatching sit 4e-6 past a rounding boundary (Blastware's
arithmetic is a hair lower) and stay mismatches.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 18:02:51 -05:00
serversdownandClaude Opus 5.5 2b698e74cf feat(decode): a histogram's interval detail -- frequencies (#50), vector sums, interval size, stop
Group B of the file-only decode, measured on DL2 2026-11-03:

- Frequency = (sample rate / 2) / half-period: 527,915 / 527,915 cells
  at 1024 sps and 1,725 / 1,725 at 2048.  #50: half_period_to_hz took a
  fixed 512 and halved every 2048-sps frequency; it now takes the rate
  (default 1024).  Blastware prints 'N/A' for a half-period of 0, '>100'
  ('>200' at 2048) at 5 samples or fewer, '<1.0' below 1 Hz.
- Each interval's vector sum, sqrt(PVS^2) at the event's range:
  771,354 / 771,354.
- Interval size: uint16 seconds at k - 40 (Series IV [8:10]).
- Stop: the footer's (2,995 / 2,999 sampled; 4 print a second earlier).

Event gains histogram_interval_sec, interval_half_periods, interval_pvs
and stop_time; the .h5 gains /intervals/half_period/<ch>,
/intervals/pvs_ips and a histogram_interval_sec attr.  The decoder walks
a histogram once (histogram_codec.channels_from_records) and takes the
event's PVS from the same records.  The checker compares each interval
column, number or Blastware's word; the test that pinned Tran Freq Hz
as blank now pins the match.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 17:34:27 -05:00
serversdownandClaude Opus 5.5 67b3ef8d0a docs(changelog): Unreleased -- group A in the protocol reference
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 17:24:40 -05:00
serversdownandClaude Opus 5.5 1309f93fa9 merge: group A in the protocol reference, and the three meanings of mic 'units'
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 17:24:29 -05:00
serversdownandClaude Opus 5.5 8f75be5f72 docs: group A in the protocol reference, and the three meanings of mic 'units'
Protocol reference:
- D.6.8 (new): the identity block (SUB FE's: serial, firmware, DSP version,
  calibration date and 'by', model; battery), the trigger-source bitmask
  in the embedded event record, and the trigger settings (sources, stop
  mode, per-channel levels, mic type) with their DL2 counts.  The
  histogram 'terminal tail' 9c 06 00 42 looks like 9c 06 00 + the
  serial's B (inferred).
- D.6.6: recorded data vs report units vs unit peaks, with the
  MiniMate Plus (s3.9.7) and Blastware (s4) manual sections.  Where the
  unit stores its own Microphone Units is unmeasured; a keypad test is
  proposed.
- D.6.9 (was D.6.7): refreshed, 28 of 88.

CLAUDE.md 'Where things stand' and the README roadmap follow.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 17:24:21 -05:00
serversdownandClaude Opus 5.5 06a4be9445 docs(changelog): Unreleased -- identity, battery and trigger settings from the file
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 17:23:07 -05:00
serversdownandClaude Opus 5.5 3ee9923f81 merge: a Blastware file's identity, battery and trigger settings (group A)
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 17:22:34 -05:00
serversdownandClaude Opus 5.5 6c2dbf0463 docs(decode_check): the units carve-out cites Instantel's manuals
Both settings are documented: the unit's Microphone Units (MiniMate Plus
manual s3.9.7, keypad Right Arrow + Setups: psi(L) / dB(L) / Pa(L)) and
Blastware's report preference (Blastware manual s4, Preferences > Units
and Channel).  The report follows Blastware's, as DL2's fleet-wide
switches showed.  Where the unit's own setting is stored is unmeasured.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 17:15:28 -05:00
serversdownandClaude Opus 5.5 8d5a9987c9 fix(decode_check): compare a mic level in the unit it is printed in
K441LA17.IN0W's report says Units 'in/s and psi(L)' yet prints
MicTriggerLevel '125.0 dB(L)'.  The value states its own unit, so that
is the one compared; the report's Units is the fallback.  It was the
only MicTriggerLevel mismatch in DL2 (SFM's 0.005158 psi is 125.0 dB).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 14:02:27 -05:00
serversdownandClaude Opus 5.5 6c2eda5f63 feat(decode): a Blastware file's identity, battery and trigger settings
Group A of the file-only decode, every field matched against every DL2
report (2026-11-03):

- Identity block before the setup name, what the live read gets from
  SUB FE: serial k-202, firmware k-147, DSP version k-138, calibration
  date k-132 + 'by' k-128, manufacturer k-94, model k-72, firmware
  minor k-193.  Event.device_info (DeviceInfo gains calibration_date /
  calibrated_by).  Serial, Version and Calibration 69,983 / 69,983.
- Battery: uint16 hundredths of a volt at k-190 (Event.battery_volts).
  69,729 exact; the other 254 are Blastware rounding half up.
- Trigger source: the two bytes between the embedded event record's
  lead and fe 80, a bitmask (0x01 Tran 0x02 Vert 0x04 Long 0x08 MicL
  0x200 Manual): 6,493 / 6,493.  Event.triggered_by.
- Trigger settings in Series IV's 0x1A layout: sources bitmask k-19,
  stop mode k-31 (0 = Fixed), each channel's float32 level at
  label+30 (geo in/s, mic psi), mic type code at MicL+4 (2 = Linear
  Weighting).  Geo level 6,447 / 6,447, mic 4,403 / 4,403; Blastware
  prints a level when its channel is a trigger source and the event
  was not Manual.  The mic level's dB uses 6895 Pa/psi (4,272 / 4,272
  against 4,271 at 6894.757).
- .h5 attrs for all of them (additive).
- Checker: SFM's side reports the ten fields; the mic trigger level
  follows the report's dB/psi.  Carve-out
  units-is-a-display-preference: dB or psi is Blastware's PC setting
  when it wrote the report -- DL2's reports switch fleet-wide in 61
  clean runs by write time, and no byte of the file separates them.
  Two tests that pinned BatteryLevel / Calibration as blank now pin the
  match.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 13:38:39 -05:00
serversdown fb14a8f7bb Merge pull request 'Release v0.33.0 — SFM reads Series-3 events from the file alone' (#56) from dev into main
Reviewed-on: #56
2026-11-01 14:33:00 -05:00
serversdown e9c01ce8d4 Merge pull request 'Release v0.32.0 — event times you can trust, and Series 4 mapped' (#54) from dev into main
Reviewed-on: #54
2026-10-27 11:00:59 -04:00
serversdown d2258dad4e Merge pull request 'Release v0.31.0 — report parity + the inverted rescue (0.29.0 → 0.31.0)' (#40) from dev into main
Reviewed-on: #40
2026-09-18 16:46:41 -04:00
serversdown e050e602c2 Merge pull request 'Release v0.29.0 — offset detector + false_trigger_reason + BlastMate serials (0.27.0→0.29.0)' (#36) from dev into main
Reviewed-on: #36
2026-09-07 15:57:37 -04:00
serversdown fc1c7c7936 Merge pull request 'Docs/claude.md corrections' (#35) from dev into main
Reviewed-on: #35
2026-08-29 15:48:33 -04:00
serversdown 7d0d12079b Merge pull request 'v0.27.0 Decoder fixes, offset exploration and testing.' (#34) from dev into main
Reviewed-on: #34
2026-08-28 22:40:34 -04:00
serversdown 5203aab849 Merge pull request 'update to 0.26.0. Big chonking update including 0.23, 0.24, and 0.25 as well.' (#33) from dev into main
Reviewed-on: #33
2026-08-27 13:43:00 -04:00
serversdown 5b65718b72 Merge pull request 'v0.23.0 - ZC freq in events store' (#31) from dev into main
Reviewed-on: #31
2026-08-06 12:12:19 -04:00
serversdown 483762607e Merge pull request 'Update to v0.22.0' (#30) from dev into main
Reviewed-on: #30
2026-07-03 15:35:20 -04:00
serversdown d0b66368d5 Merge pull request 'update to v0.21.1, thor data import successful' (#29) from dev into main
Reviewed-on: #29
2026-06-01 16:54:23 -04:00
serversdown 2eb1d25028 Merge pull request 'v0.20.0 -- Full s3 event parse and PDF creation.' (#28) from dev into main
Reviewed-on: #28
2026-05-28 17:54:31 -04:00
claude cc821f9ee3 hotfix: fix dockerfile on main to fix import bug on prod 2026-05-21 20:42:15 +00:00
73 changed files with 13830 additions and 1043 deletions

No files matched your search

+345 -1
View File
@@ -4,9 +4,125 @@ All notable changes to seismo-relay are documented here.
---
## Unreleased
## v0.34.0 — 2026-11-04
**SFM reaches Series-4 parity, and reads most of Blastware's report from the
event file alone.**
Two lines of work ship together.
**Series-4 parity** (`feat/series4-sfm-parity`). One device door, by serial,
for both series. Each change is audited, identity-checked, sent once and read
back. Benched on BE9441 and UM20147.
- reads and downloads
- start / stop monitoring
- call-home on / off
- settings changes (preview → send → read back)
It also fixes MiniMate request framing (#46) and the 5A walk across a 64 KB
page.
**The file-only decode, groups A–D.** 47 of Blastware's 88 report fields now
match on every DL2 event, about 6 before v0.33.0. Eight more match on all but
one or two of 6,524 waveforms.
- **Fixed:**
- Sensitive-range events no longer read 8× high
- histograms the waveform codec had claimed, and short histograms with a
loud interval, now decode
- histograms are no longer a day late
- every histogram's start and stop are Blastware's own (#51), not a second
early
- interval frequencies follow the sample rate (#50)
- **New from the file:**
- the job number
- the unit's serial, version, calibration date and battery
- the trigger source and levels
- each interval's frequencies, vector sum and time
- the peak dates and times
- a waveform's time of peak and peak acceleration
- **Events are identified by unit + time + type:** a waveform and its histogram
may share a second.
Prod still overlays a paired ASCII report onto the decode. That overlay is the
plan's step 3 and is not part of this release.
⚠ **This release migrates the events table and owes a backfill that moves every
Series-3 histogram's stored time by one second.** See *Migration*.
### Fixed
- ✅ **MiniMate requests and config writes are framed as Blastware frames them
(#46; `feat/series4-sfm-parity`).**
- Every request escapes 02 / 03 / 04 / 10.
- A config write is an ordinary escaped request carrying a whole block (as
read, plus two bytes). All four blocks are checked before the first frame.
- SFM's frames equal Blastware's in the 2026-04-20 and 2026-10-26 captures.
Benched on BE9441 2026-11-04.
- ✅ **The 5A walk crosses a unit's 64 KB page.** The walk is 32-bit linear
(the CLAUDE.md "KNOWN BUG"); BE9441's page-crossing events rebuild Blastware's
own files byte for byte.
- A one-event download is whole or an error.
- A non-first event's stream has no metadata pages.
- **A MiniMate settings read is assembled as content** (measured at the bench
2026-11-04).
- Unescape each 1A frame and drop the one non-content byte that starts every
frame but the last: 2,090 bytes headed by N = 2090.
- The read takes exactly the length it asked for. When a reply's checksum
byte is itself escaped (about 1 frame in 85), the parser leaves its 0x10 in
the data. It hit the first live read; the recordings never had it. The
waveform-data read now trims it too.
- **A live download is held to its record type (#51):** a same-second
waveform / histogram twin is no longer skipped as "already stored". An untyped
row at that second still counts as stored.
- Smaller wire fixes from the parity benches:
- SUB 0x15's serial is cut at its first NUL.
- 0x1C reads a histogram run as monitoring.
- A MiniMate that boots on connect is waited for.
- A start's read-back waits out the sensor check and wakes the unit.
- A built call-home image is framed once.
- ✅ **#51: events are identified by unit + time + type, and histograms take
Blastware's times.**
- **The new key.** The events table was `UNIQUE(serial, timestamp)`, one
event per unit per second. A waveform and its histogram share a second
legitimately: 209 times in prod's 2026-09-30 store. The key is now
`UNIQUE(serial, timestamp, record_type)` (agreed with Brian 2026-11-03).
- **Migration 3** rebuilds the table from its own definition with only the
key swapped, in one transaction. Every column, row and id is kept, and
the indexes are recreated.
- **Lookups:** the upsert, the estimate guard and the restamp match on
type. The restamp also re-types a file's own row in place. An untyped
event still dedups against an untyped row.
- **Histogram times.** A histogram's start and stop now come from its own
event record (lead `00 28 05 00`, source `04 00`, marker `fe f5`). That is
Blastware's Histogram Start and Stop on 63,490 / 63,490 DL2 histograms; the
footer's start was a second early on 97%. Without a validated record, the
footer stands and the decoder logs a decode problem.
- **Interval times and peak times follow:**
- each interval's printed time is its end, start + (i + 1) × interval,
capped at the stop (2,308,524 / 2,308,524 rows; `interval_times`)
- each peak's date and time is its interval's
- **Decode checker:** 760,410 comparisons fixed, 0 regressions, **47 of 88**
fields fully match (was 34). Histogram start and stop times, interval
times and the ten peak date/time fields match every DL2 histogram.
- **Rehearsed on a copy of prod's 2026-09-30 snapshot (15,432 events):**
- The migration kept every row identical, rebuilt the indexes and passed
the integrity check, in 0.27 s.
- `backfill_sidecars.py`: 11,944 files, 0 errors. 9,852 Series-3
histograms moved +1 s in place, with no id lost and review state
untouched. The 209 same-second pairs coexist, and 0 collisions were
refused. (It also created 341 rows for store files that never had one:
the known one-time behaviour, not duplicates.)
- `backfill_event_shape.py`: exit 0, `cleared_stale` 0.
- ⚠ **Schema migration + codec change.** SFM migrates the events table by
itself on first start: back up `seismo_relay.db` first. The release
backfill (`backfill_sidecars.py` then `backfill_event_shape.py`) moves
every Series-3 histogram's stored time by one second, in place.
- Terra-View pairs twins by peak values and reads rows by id: no change
needed there.
- Note for Terra-View's changelog: Series-3 histograms move forward one
second, so an event can cross a deployment-window edge.
- Three tests that pinned the old footer start now pin the record's. The
estimate-guard test's neighbour is now the same type.
- **A Blastware file's geophone range comes from its setup, so Sensitive
events no longer read 8× high.**
- **Where it is:** in the setup's channel blocks, the byte 29 after each
@@ -92,6 +208,154 @@ All notable changes to seismo-relay are documented here.
change.
### Added
- **Series-4 parity in SFM: everything by serial, for both series**
(`feat/series4-sfm-parity`, merged 2026-11-04; spec
`docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md`).
- **One door, `DeviceAccess`.**
- A unit is addressed by its serial: UM is Series 4, BE / BA is Series 3.
The unit's own answer is checked before anything is sent.
- A Micromate's line is held between requests and released when idle or
on RADIO RING.
- One connection per unit; 423 while busy.
- **Reads, both series:** `GET /device/info`, `/device/monitor/status`,
`/device/settings`, `/device/events` and `POST /device/events/download`.
- A download is stored as the watcher stores it, through the Blastware /
IDF import path, typed.
- It never overwrites a stored event.
- SFM's MiniMate files carry Blastware's W/H type letter.
- **Changes, both series, each audited** (a `device_commands` row per
attempt), identity-checked, sent once, never retried, read back:
- start / stop monitoring;
- call-home on / off: `GET /device/call_home/state`,
`POST /device/call_home/{enable,disable}`;
- **settings**, `POST /device/settings/change`.
- **Settings, in detail:**
- A preview (dry run) shows old → new and returns a revision; a live
change must carry it, covering the unit's block and the changes asked for.
- Fields: record mode, sample rate, histogram interval, record time,
geophone trigger, the four notes, job number and its report flag, and
(MiniMate) range and alarm.
- Limits are the units' own, from Instantel's manuals, checked on the
block that would result.
- Refused before anything is sent: a monitoring unit, a stale preview, a
Micromate on its factory setup, or one whose schedule would load another
setup. SFM reads `schedule.dat`, read-only.
- **One settings codec for both series** (`micromate/setup_fields.py`): a
MiniMate's settings block is Series IV's `0x1A` layout. All 11 Blastware
compliance writes reproduce from the block before them.
- **The page:**
- units by serial, with the series badge from the unit's own answer;
- the events list and download, start / stop, the Call Home tab;
- the Config tab's Preview → Send → "the unit now holds";
- page JavaScript in `sfm/static/`, tested through Node (no inline JS).
- **Benched on BE9441 and UM20147:** phase 4 on 2026-11-03, phase 5 on
2026-11-04. Every change was acknowledged, read back and confirmed on the
unit's screen; both units were restored byte for byte.
- ⚠ A MiniMate's open setup menu loses a remote change when the operator
presses Cancel or Save (the menu writes its whole-block copy back). The
preview warns.
- ⚠ The Micromate scheduler switch is in no block SFM reads, so a leftover
schedule blocks a change even with the scheduler Off.
- ⚠ **Operational:** additive schema only. SFM creates `device_commands`, or
adds `sent` / `states` to an older one, on first start; this branch does not
touch `events`. No `TOOL_VERSION` bump and no backfill from this branch:
event decoding is unchanged. Production ingest (the watchers) is untouched;
the new device routes are used only from SFM's page and API.
- **A waveform's time of peak, vector-sum time and peak acceleration** (group D,
part 1 of the file-only decode). Measured on DL2 2026-11-04.
- **Time of peak** = (first peak sample − pre-trigger samples) / sample rate,
per channel including the mic.
- **The vector sum's time**: the same, on √(T² + V² + L²).
- **Peak acceleration** = the largest |v[i+1] − v[i]| × sample rate / g, which
the manuals describe as "subtracts two velocity readings and divides the
result by the elapsed time between them".
- Blastware's g is fitted: every printed acceleration in DL2 bounds it, and
together they leave [386.2236, 386.2240] in/s².
- That is 9.81 m/s² (386.2205) plus an offset not explained, as with the
mic's fitted dB offset. The standard 9.80665 m/s² fits 17,806 of
19,479 values; the fitted value fits 19,475.
- **`PeakValues` gains** `*_time_of_peak`, `pvs_time` and `*_peak_accel_g`,
filled for waveforms only.
- **Decode checker:** 52,177 comparisons fixed, 0 regressions. Times of peak
are 6,523 / 6,524 on every channel, peak acceleration 6,522–6,523 / 6,524.
Every miss is in two 2019 files (O117I1NK.R70W on all channels, S353I5PZ
on Vert), not yet explained.
- **Not shipped yet:** peak displacement and ZC frequency. They follow the
manuals' methods (half the largest half-cycle integral; the half-cycle at
the peak), but match only 84% and 46%, so Blastware does something more.
- ⚠ **Codec change:** it rides this release's `TOOL_VERSION` bump and
backfill. No schema change; the new values are not stored in the DB or
the `.h5` yet.
- **A histogram's interval detail: frequencies, vector sums, interval size and
stop** (group B of the file-only decode). Measured on DL2 2026-11-03.
- **Frequency** = (sample rate / 2) / half-period: 527,915 / 527,915 cells
at 1024 sps and 1,725 / 1,725 at 2048.
- ✅ **Fixes #50.** `half_period_to_hz` used a fixed 512 and halved every
2048-sps frequency. It now takes the rate (default 1024).
- Blastware prints "N/A" for a half-period of 0, ">100" (">200" at 2048)
at 5 samples or fewer, and "<1.0" below 1 Hz.
- **Each interval's vector sum**, √PVS² at the event's range.
- **Interval size:** uint16 seconds at `k − 40` (Series IV `[8:10]`).
- **Stop time:** the footer's.
- **`Event` gains** `histogram_interval_sec`, `interval_half_periods`,
`interval_pvs` and `stop_time`.
- **The `.h5` gains** `/intervals/half_period/<ch>` and `/intervals/pvs_ips`,
plus a `histogram_interval_sec` attribute.
- **Decoder:** a histogram is now walked once
(`histogram_codec.channels_from_records`).
- **Decode checker:** 508,080 comparisons fixed, 0 regressions, 34 of 88
fields fully match (was 28).
- Frequencies on all four channels, interval size and stop date match
every DL2 histogram.
- Interval vector sum: 63,497 match, plus 17 clipped intervals now under
the saturation carve-out. Blastware prints OORANGE when the sum exceeds
the range in an interval where it clamped a channel (17 / 17).
- 4 cells sit 4e-6 past a rounding boundary and stay mismatches.
- 58 stop times are Blastware a second earlier, part of #51.
- ⚠ **Codec change:** it rides the next release's `TOOL_VERSION` bump and
backfill. The `.h5` additions are additive. No schema change.
- **A Blastware file's identity, battery and trigger settings** (group A of the
file-only decode). Every field is matched against every DL2 report
(2026-11-03).
- **Identity block** before the setup name: what the live read gets from
SUB FE.
- serial `k − 202`, firmware `k − 147`, DSP version `k − 138`, firmware
minor `k − 193`
- calibration date `k − 132` and "by" `k − 128`
- manufacturer `k − 94`, model `k − 72`
- Filled into `Event.device_info`; `DeviceInfo` gains `calibration_date` /
`calibrated_by`.
- Serial, Version and Calibration match 70,042 / 70,042.
- **Battery:** uint16 hundredths of a volt at `k − 190`
(`Event.battery_volts`), 70,042 / 70,042. Blastware rounds half up
(6.25 → "6.3 Volts").
- **Trigger source:** the two bytes between the embedded event record's lead
and `fe 80`, a bitmask (`0x01` Tran, `0x02` Vert, `0x04` Long, `0x08`
MicL, `0x200` Manual). 6,524 / 6,524 (`Event.triggered_by`).
- **Trigger settings,** in Series IV's `0x1A` layout:
- the sources bitmask at `k − 19`
- the stop mode at `k − 31` (0 = Fixed)
- each channel's float32 level at label + 30 (geo in/s, mic psi)
- the mic type code at MicL + 4 (2 = Linear Weighting)
Blastware prints a level when its channel is a trigger source and the
event wasn't Manual. Geo level 6,484 / 6,484, mic level 4,412 / 4,412
(its dB uses 6895 Pa/psi).
- **`.h5`:** all of them as attributes (additive).
- **Decode checker:** 444,188 comparisons fixed, 0 regressions, 28 of 88
fields fully match (was 18).
- A mic level is now compared in the unit it is printed in: K441LA17.IN0W
prints dB under psi Units.
- New carve-out `units-is-a-display-preference` (3,532 events). dB or psi
in a Blastware report is that PC's Blastware preference when it wrote the
report (Blastware manual §4, Preferences → Units and Channel), not the
unit's Microphone Units setting (MiniMate Plus manual §3.9.7). DL2's
reports switch fleet-wide in 61 clean runs by write time, and no byte of
the file separates them.
- Single-value fields are proven for that value only: Version `10.72-8.17`,
stop mode Fixed, mic type Linear.
- ⚠ **Codec change:** it rides the next release's `TOOL_VERSION` bump and
backfill. No schema change.
- **A Blastware file's job number, and whether Blastware shows it.**
- **Where it is:** the setup block has Series IV's `0x1A` layout here too.
The report flags sit at 9 bytes before the setup name, with bit `0x02`
@@ -113,7 +377,47 @@ All notable changes to seismo-relay are documented here.
backfill (`backfill_sidecars.py` then `backfill_event_shape.py`). The new
`.h5` attributes are additive. No schema change, no migration.
### Removed
- **`POST /device/config` and `POST /device/config/project` answer 410**,
pointing at `POST /device/settings/change`. Terra-View does not call them.
Removed with them, because they wrote a live unit through the encoder #46
found wrong:
- `MiniMateClient.apply_config`, `set_project_info` and
`_encode_compliance_config`;
- `poc_set_project.py`, and `experiments.py`'s EXP6.
### Protocol / Documentation
- **The parity benches in both protocol references:**
- Series III: the settings write measured end to end, the escaped-checksum
stray byte, the keypad menu writing its whole-block copy back, the alarm at
channel +38, and `[26:28]` re-set while monitoring.
- Series IV: the first setup push, with the unit's CRC equal to SFM's; the
schedule read on a real unit; the scheduler switch in none of the blocks.
- Spec and plan: `docs/superpowers/specs/2026-11-03-sfm-phase5-settings-design.md`,
`docs/superpowers/plans/2026-11-03-sfm-phase5-settings.md`.
- **Histogram timing in the protocol reference (D.6.10):**
- the histogram's own event record
- the interval-time and peak-time rules
- "histograms stay on ts1" retracted in place
- CLAUDE.md records the unit + time + type key
- Docs only.
- **Group B in the protocol reference (D.6.9):**
- interval size, the stop, and per-interval frequency, with Blastware's
words (`N/A`, `>100` / `>200`, `<1.0`)
- each interval's vector sum, with its OORANGE rule
- #50's fixed-512 formula is retracted in place
- CLAUDE.md and the README roadmap follow
- Docs only.
- **Group A in the protocol reference, and the three meanings of mic
"units".**
- **D.6.8:** the identity block, the trigger-source bitmask and the trigger
settings.
- **D.6.6:** recorded data vs report units vs unit peaks, with the
MiniMate Plus and Blastware manual sections. CLAUDE.md carries the same
glossary.
- 🔶 Inferred: the histogram "terminal tail" `9c 06 00 42` is `9c 06 00`
plus the serial's `B`.
- Docs only: no code change, no migration.
- **Where file-only decoding stands, and that prod's ASCII overlay is
scaffolding.**
- **CLAUDE.md "Where things stand"** now says plainly that a paired
@@ -155,6 +459,46 @@ All notable changes to seismo-relay are documented here.
- **CLAUDE.md "Where things stand"** now reflects the range fix.
- Docs only: no code change, no migration.
### Migration
⚠ **Schema migration and backfill.** Rehearsed twice on a copy of prod's
2026-09-30 snapshot (15,432 events), before and after the parity merge, with
identical results.
**Before you start:**
- `TOOL_VERSION` is bumped to **0.34.0**, which gates the regeneration, so no
`--force` is needed.
- **Back up `seismo_relay.db` first.**
**Then:**
1. **Deploy.** On first start SFM migrates the database by itself.
- The events table is re-keyed `UNIQUE(serial, timestamp, record_type)`
(Migration 3): every row and id is kept and the indexes are rebuilt.
Rehearsal: 0.27 s, every row identical, integrity ok.
- `device_commands` is created.
2. **In the `sfm` container, `python scripts/backfill_sidecars.py`** re-decodes
every event file. ⚠ **Plan an overnight run:** the store holds about 64,000
events after the 2200-day watcher forward, at about 1.5 files/s on the NAS,
so roughly 12 hours.
- **Every Series-3 histogram's time moves forward one second, in place**,
with id and review state kept. Rehearsal: 9,852 moved, 0 refused, no id
lost.
- **The same-second waveform/histogram pairs coexist** (209 in the
snapshot).
- It also creates a row for any store file that never had one (341 in the
snapshot): the known one-time behaviour, not duplicates.
- **Report-less events** pick up every new field. **Report-paired events**
keep the report's overlaid peaks, notes, sample rate and record time.
3. **`python scripts/backfill_event_shape.py --db-path bridges/captures/seismo_relay.db
--store-root bridges/captures/waveforms`** recomputes shape and offset
metrics. Rehearsal: exit 0, `cleared_stale` 0.
**Terra-View** needs no change: it pairs twins by peak values and reads rows by
id. Moving a histogram forward one second can carry an event across a
deployment-window edge.
**Series-4** event times do not move.
## v0.33.0 — 2026-11-01
**SFM reads Series-3 events from the file alone, and proves it against
+57 -12
View File
@@ -2,7 +2,7 @@
Ground-up Python replacement for **Blastware**, Instantel's Windows-only software for
managing MiniMate Plus seismographs. Connects over direct RS-232 or cellular modem
(Sierra Wireless RV50 / RV55). Current version: **v0.33.0**.
(Sierra Wireless RV50 / RV55). Current version: **v0.34.0**.
Stack-level context — which repo owns what, and how the three project versions
pair — lives in `../terra-view/docs/tmi-stack.md`, which is also loaded as
@@ -45,13 +45,40 @@ Read this first when picking the project back up.
- **Byte layouts** of every field read from the file:
`docs/instantel_protocol_reference.md` Appendix **D.6**.
**Where the decoder stands on `dev`** (2026-11-03, run `20261103-121047`):
**18 of 88 fields match on every event**, up from about 6 before v0.33.0.
The four `dev` fixes below share one release and one backfill.
**Where the decoder stands on `dev`** (2026-11-03, run `20261103-213557`):
**47 of 88 fields match on every event**, up from about 6 before v0.33.0.
Everything below on `dev` shares one release and one backfill. Groups A, B
and C are done, which also fixed #50 and #51.
- 🔑 **Events are keyed unit + time + type:** `UNIQUE(serial, timestamp,
record_type)` (#51, Migration 3 in `sfm/database.py`, `dev`).
- A waveform and its histogram may share a second: 209 times in prod's
2026-09-30 store.
- Any lookup "by event" must include the type.
- An untyped event still dedups against an untyped row.
- Rehearsed on a copy of the prod snapshot: rows and ids kept, 9,852
histograms moved +1 s in place.
- ✅ **Match on every event:**
- sample rate, record time, pre-trigger, notes and event type (v0.33.0)
- geophone range, job number, event times (6,524 / 6,524) and histogram
start dates (63,518 / 63,518) — `dev`
- group A (`dev`, reference D.6.8): serial, version, calibration, battery,
trigger source, geo and mic trigger levels, stop mode, mic type
- group B (`dev`, D.6.9): interval frequencies, vector sums, size, stop
- group C (`dev`, D.6.10): histogram start and stop from the histogram's
own event record, interval times, and the peak dates and times
- 🔑 **"Units" means three different things — keep them apart** (reference
D.6.6):
- **Recorded data:** the mic samples and interval peaks in the file, as
raw counts with no unit.
- **Report units:** dB(L) or psi(L) in a report.
- A Blastware report uses that PC's Blastware preference at the moment
it wrote the report; carve-out `units-is-a-display-preference`.
- SFM's report uses SFM's own fixed choice.
- **Unit peaks:** the unit's own summary, in its keypad Microphone Units
setting. Shown on its screen, in Blastware's event list, and in the 0C
record.
- Where the unit stores that setting is not measured yet; a keypad test
on a bench unit would show it.
- ✅ **Geophone samples** are exact on **6,524 / 6,524** waveforms in every
year (`dev`; v0.33.0 had 6,491, its 33 others being Sensitive-range events
read 8× high).
@@ -65,18 +92,14 @@ Read this first when picking the project back up.
- ✅ **Histogram PVS** = the stored per-interval PVS²: 69,989 / 70,042.
**Mic:** one count = 0.25 Pa, dB offset 81.9384; a few dozen stragglers.
- ❌ **Open:**
- histogram start times are 1 s early (#51; fixing it moves every stored
histogram by 1 s, and the event key is (serial, time), so it needs a
decision first)
- the mic stragglers: ~20 one-minute histograms with an interval or two off
- Blastware prints `OORANGE` when the vector sum alone exceeds the range
(a carve-out to prove)
- ⬜ **Not read yet, in the order proposed** (2026-11-03):
- **A. Setup fields:** trigger source and levels, stop mode, mic type,
display units, firmware version, serial number, calibration, battery.
- **B. Histogram interval detail:** per-interval frequencies (#50: they
assume 1024 sps), per-interval PVS, interval size, stop time.
- **C. #51 timing:** start time, per-interval times, peak times.
- ~~**A. Setup fields**~~ ✅ done on `dev`.
- ~~**B. Histogram interval detail**~~ ✅ done on `dev`. Frequencies (#50),
per-interval PVS, interval size, stop.
- ~~**C. #51 timing**~~ ✅ done on `dev`.
- **D. Blastware's waveform calculations:** ZC frequency, acceleration,
displacement, time of peak.
- **E. Sensor check results.**
@@ -285,6 +308,28 @@ Read this first when picking the project back up.
menu. ⚠ **Neither series takes a call-home change while monitoring:** a MiniMate
returns its device-info block, and a Micromate acks the write and ignores it.
SFM refuses both up front.
**Phase 5 built 2026-11-03, benched 2026-11-04:** change a unit's settings by serial,
both series (`POST /device/settings/change`; the Config tab's Preview, then Send).
Spec `docs/superpowers/specs/2026-11-03-sfm-phase5-settings-design.md`.
- 🔑 **A MiniMate's settings block IS Series IV's `0x1A` layout** (measured):
the 1A read assembles to 2,090 bytes headed by N = 2090, and all 11
Blastware compliance writes reproduce from the block before them. One codec
serves both series: `micromate/setup_fields.py`.
- Limits are the units' own, from Instantel's manuals (Brian). A live send
needs its preview's revision; refused up front: monitoring, a Micromate on
its factory setup or whose schedule would load another setup.
- Retired: `/device/config` (410), `apply_config`, `_encode_compliance_config`.
- **Benched 2026-11-04, both series:** every change acknowledged, read back,
and confirmed on the unit's screen; both units restored byte for byte. The
MiniMate alarm write is measured and now on.
- ⚠ **A MiniMate's open setup menu wins:** a change sent while it is open is
lost when the operator presses Cancel or Save (the menu writes its whole-block
copy back). The preview warns; nobody in the menus while the office sends.
- ⚠ An escaped checksum byte leaves a stray `0x10` in a Series-3 reply's data
(about 1 frame in 85). The settings and waveform reads take exactly what they
asked for; other reads are unaudited for it.
- ⚠ The Micromate scheduler switch is not in any block SFM reads, so a leftover
schedule blocks a change even with the scheduler Off.
**Ring path measured the same night:** with THOR's watchdog off, a call-home
reaches THOR when nobody holds the line, and **is lost when SFM holds it** --
the unit takes SFM's connection for the call, times out and does not retry.
+25 -5
View File
@@ -1,4 +1,4 @@
# seismo-relay `v0.33.0`
# seismo-relay `v0.34.0`
A ground-up replacement for **Blastware** — Instantel's aging Windows-only
software for managing seismographs. Supports both the **MiniMate Plus
@@ -95,6 +95,25 @@ over direct RS-232 or cellular modem (Sierra Wireless RV50 / RV55).
>
> ⚠ The deploy owes a backfill; it does not move event times. See the
> changelog's *Migration*.
>
> **v0.34.0 (2026-11-04)** reaches Series-4 parity and reads most of
> Blastware's report from the event file alone.
> - **Series-4 parity:** one device door by serial for both series, with
> reads, downloads, start/stop, call-home and settings changes, each audited
> and read back. MiniMate request framing is fixed (#46).
> - **The file-only decode:** 47 of Blastware's 88 report fields match on
> every DL2 event, and 8 more on all but one or two.
> - Sensitive-range events are no longer 8× high.
> - Histograms decode correctly and carry Blastware's own times (#51).
> - Interval frequencies follow the sample rate (#50).
> - New from the file: the job number, serial, version, calibration,
> battery, trigger source and levels, interval detail, peak times and
> peak acceleration.
> - **Events are identified by unit + time + type.**
>
> ⚠ The deploy migrates the events table and owes an overnight backfill that
> moves every Series-3 histogram time by one second. See the changelog's
> *Migration*.
> See [CHANGELOG.md](CHANGELOG.md) for full version history.
---
@@ -647,18 +666,19 @@ Implementation steps (concrete):
3. flip ingest so reports are kept only for checking (retire the overlay)
4. stop the watchers forwarding reports
**Done so far: 18 of 88 report fields match on every DL2 event.**
**Done so far: 47 of 88 report fields match on every DL2 event.**
- In v0.33.0: setup fields, notes, event type, histogram PVS, mic.
- On `dev`:
- the geophone range
- the job number
- histograms that decoded wrongly
- the footer: no more day-late histograms; every waveform time exact
- serial, version, calibration, battery, trigger source and levels, stop mode, mic type
- histogram interval detail: frequencies (#50 fixed), per-interval PVS, interval size, stop
- histogram start, stop, interval and peak times (#51 fixed); events keyed unit + time + type
- A Blastware report's dB/psi is its PC's preference, not anything in the event file: a carve-out.
**Next:**
- setup fields still unread: trigger, stop mode, units, serial, calibration, battery
- histogram interval detail: frequencies (#50), per-interval PVS, interval size, stop time
- histogram start times (#51)
- the values Blastware computes itself: ZC frequency, acceleration, displacement, time of peak
- the sensor check results
- the monitor log
+142 -9
View File
@@ -11,6 +11,11 @@
| Date | Section | Change |
|---|---|---|
| 2026-11-04 | SUB 1A / 09 reads, SUB 68–74 settings write, the keypad | **SFM's settings write, benched on BE9441 (Brian at the unit; ~12 writes, each with his go).** **Every write** -- trigger 0.04 ↔ 0.05, a note, several fields at once (Project, job number + its report flag, trigger), the alarm 1.0 ↔ 1.5, and a full restore -- was acknowledged on all nine steps (`97 8C 8E×5 8D 7D 7C 96 8B 8D`), read back as sent, and **confirmed on the unit's own screen**; the unit ended byte for byte as found. Moved bytes were exactly the field's: trigger f32 at each geophone channel +30 (`+31..+33` moved), **alarm f32 at channel +38** (`+39` moved; the first Series-3 alarm write), job number `[40:42]`, its report bit `[39]` `0x02`, a note's value window. **`[26:28]`** went `01 7f` → `00 00` on SFM's first write (Blastware's value) and the unit **set `01 7f` again during the next monitoring session**. The **two bytes after the block** went out as `00 00` (Blastware sends a per-unit constant) and were taken. **🔑 Escaped-checksum artifact:** when a reply's checksum byte is itself escaped (02 / 03 / 04, ~1 frame in 85), `S3FrameParser` keeps the escape's `0x10` and strips only the byte after it, so the frame's data gains one trailing `0x10`. It hit the first live 1A read (frame B 1,026 bytes after the header); the 12 recorded reads never had. SFM's settings read and waveform read now take exactly the length they asked for. **🔑 The keypad menu wins:** a write sent while the setup menu was open was acknowledged and read back, then **lost when the operator pressed Cancel or Save** -- the menu writes its own copy of the **whole** block back (both times the block returned byte for byte to its state when the menu was opened). A keypad Cancel with nothing pending leaves the block unchanged. **While monitoring**, the 1A read returns the device-info block (SFM refuses, nothing sent), and the opening poll was answered only intermittently (2 of 3 attempts timed out). Code: `minimateplus.protocol.read_compliance_content` / `read_waveform_data_raw`, `micromate.setup_fields`; notes `~/bench-logs/2026-11-04-sfm-settings/`. |
| 2026-11-03 (5) | SUB 1A / 71 / 69 (settings read and write) | **The settings block, read and written as content (measured, BE9441's 10-26 recording and BE11529's 2026-04-20 captures).** **Read:** unescape each 1A data frame and take `data[11:]`; every frame but the last starts with one `00` that is not content; dropped, the frames join into **2,090 bytes headed by N = 2090: Series IV's `0x1A` content layout** (12 / 12 reads, Blastware's 4 × 512 + 42 and SFM's 1024 + 1024 + 42). The old "stable anchor" `be 80 00 00 00 00` is content `[12:18]` (pre-trigger −0.25 + stop mode Fixed). **Round trip:** the read after each of Blastware's two 10-26 writes equals the image it had just written, all 2,090 bytes (2 / 2). While monitoring, the read returns the device-info block (`0e 'BE9441' …`, 5 / 5). **`[26:28]`:** Blastware writes `00 00` on all 11 writes; the unit reads `01 7f` after a monitoring session (BE9441 10-26, BE11529 4-20 15:19) and sets it by itself; meaning unknown. **The two bytes after the block** (`[2090:2092]` of the 0x71 image) are Blastware's own per-unit constant -- `7c ea` on all nine of BE11529's writes, `0c e9` on both of BE9441's -- not the block's CRC-16/AUG, and in no reply of BE9441's three-hour session; SFM sends `00 00`. **`0x09` `[200:202]`:** Blastware echoed the unit's `8c 76` on all nine April writes; on 10-26 it read `17 17` and wrote `78 76` (read back so); meaning unknown. **Blastware re-renders the mic trigger level:** on BE11529's first write (4-20 15:19) the unit read 0.005 and 0.01 psi in its two `MicL` channel blocks (3 and 7; Series 3 carries 8 channel blocks of 48 bytes from `[1708]`, the second four prefixed `0x32`) and Blastware wrote 0.004983 and 0.010058 -- the same levels to its 0.1 dB; every other write left them alone. **Every one of the 11 Blastware writes reproduces** from the block before it with only the fields Blastware changed (plus that re-render and, on 10-26, the mic bit of `[25]`). Code: `minimateplus.protocol.assemble_compliance_content`, `read_compliance_content`, `micromate.setup_fields`; tests `tests/test_s3_settings_read.py`, `tests/test_setup_fields.py`. |
| 2026-11-03 (4) | Appendix D.6.10 (NEW), D.6.11 | ✅ **Histogram timing from its own event record (#51).** `00 28 05 00` `04 00` `fe f5` [start][stop]: Blastware's Histogram Start and Stop on 63,490 / 63,490 each; exactly one per histogram, start 0–1 s after the footer's ts1. Interval time = its end (start + (i + 1) × interval, capped at the stop), 2,308,524 / 2,308,524 rows; a peak's date/time = its interval's. Retracted: "histograms stay on ts1" (it held only while SFM's events were unique on serial + time; now unit + time + type). 47 of 88 report fields match on every DL2 event. |
| 2026-11-03 (3) | Appendix D.6.9 (NEW), D.6.10 | ✅ **Histogram interval detail.** Interval size = uint16 seconds at `k − 40`; stop = footer ts2. Frequency = (sample rate / 2) / half-period, 527,915 / 527,915 cells at 1024 sps and 1,725 / 1,725 at 2048 — **#50 retracted** (a fixed 512 halved 2048-sps frequencies). Blastware's words: `N/A` (half-period 0), `>100` / `>200` (≤ 5 samples), `<1.0`. Per-interval vector sum √PVS²: 63,497 histograms; `OORANGE` when over range with a clamped channel, 17 / 17. 34 of 88 report fields now match on every DL2 event. |
| 2026-11-03 (2) | Appendix D.6.6, D.6.8 (NEW), D.6.9 | ✅ **Identity, battery and trigger, from the file.** **D.6.8:** the identity block before the setup name is SUB FE's (serial `k − 202`, firmware `k − 147`, DSP `k − 138`, calibration `k − 132` + by `k − 128`, model `k − 72`; battery uint16 /100 at `k − 190`); all 70,042 / 70,042. The embedded event record's two unknown bytes are the **trigger source** bitmask (6,524 / 6,524). Trigger sources `k − 19`, stop mode `k − 31`, per-channel trigger level float32 at label + 30, mic type at MicL + 4 (Series IV's code). **D.6.6:** recorded data vs report units vs unit peaks, with the manual sections; a Blastware report's dB/psi is the PC's preference. 🔶 `9c 06 00 42` (the histogram "terminal tail") looks like `9c 06 00` + the serial's `B`. 28 of 88 report fields now match on every DL2 event. |
| 2026-11-03 | Appendix D.3.3, D.6.1, D.6.3, D.6.5, D.6.7, §8 | ✅ **File-only decode, second pass (on `dev`).** **D.3.3:** the footer is the file's last 26 bytes (70,041 / 70,041); an earlier stop-time record fooled the first-match search on 14 files, making histograms a day late. Its `[18:24]` is **not** fixed (retracted). **D.6.1:** STRT[18] now picks the codec; the waveform codec had claimed 2018 5 s histograms. **D.6.3:** the job number (flags `k − 9` bit `0x02`, uint16 at `k − 8`; 2,997 / 2,997). **D.6.5:** the PVS² high word is non-zero above 1.28 in/s (retracted "reads 0000"), so the layout check now uses peak ≤ PVS ≤ √3·peak (34,502,955 / 34,502,955); Blastware's "Number of Intervals" is the monitoring time ÷ the interval. **§8:** where the 1995 default-clock events come from. 18 of 88 report fields now match on every DL2 event. |
| 2026-11-03 | call home (SUB 2C / 7E / 7F) | **SFM's call-home write, measured both ways.** SFM's 0x7E image (`write_image` of the 0x2C read with byte 5 set, framed ONCE) and its 0x7F confirm reproduce Blastware's 2026-04-20 enable and disable writes byte for byte (BE11529; `tests/test_s3_call_home_bw_frames.py`). Live on BE9441, idle: a no-op, on and off were all acked (0x81 / 0x80) and read back, and the unit's menu agreed. Only byte 5 changes: no unit-maintained field, unlike Series 4's `[118:120]`. Byte 5 is read from the UNESCAPED block. ⚠ Unescaping is not idempotent, so a built image must never pass through `write_image` again: a call-in time of 16:02-16:04 is `10 02`-`10 04` in the image. ⚠ **While monitoring, the unit answers the 0x2C read with its DEVICE-INFO block** ('Instantel', 'MiniMate Plus', its serial), as it answers 1A. Idle again, minutes later, it returns the call-home block. So a monitoring unit's call-home cannot be read-modify-written; SFM refuses with 'stop monitoring first'. A blind write while monitoring stays untested on purpose. |
| 2026-11-02 | Appendix D.3.1, D.6 (NEW), §15 | ✅ **Event fields SFM reads from the file alone (v0.33.0, plus the range on `dev`).** New D.6 records the bytes and the DL2 verification for each field: the record type `STRT[18]`, the recording-setup block (sample rate, pre-trigger, record time, the four notes), the geophone range (label + 29 in the setup's channel blocks), each histogram interval's PVS², and the mic scale (one count = 0.25 Pa). **Retracted in place:** D.3.1's `STRT[20]` = record time (it is `00` on every DL2 file; the "70 s" SFM used to report was `STRT[18]`, the record-type byte), and the 2026-08-26 reading of sub-minute histogram records as little-endian (big-endian from byte 5 since v0.32.0, #47/#49). **For #48:** the file's copy of the block puts the pre-trigger where the 1A "stable anchor" `be 80 00 00 00 00` sits. In the file, though, it is each event's own pre-trigger, which varies on the same unit on the same day (253–256 samples at 1024 sps), and Blastware reports it per event. So the file says little about whether the live 1A loses its anchor, and #48 stays open. |
@@ -3799,28 +3804,156 @@ Each interval stores its peak vector sum **squared**:
- **Verified:** interval psi mismatches fell from 42,783 to 26, and mic peak mismatches from 345
to 40.
#### D.6.7 Not read from the file yet
**Three things share the word "units". Keep them apart** (2026-11-03):
*Updated 2026-11-03. 18 of 88 report fields now match on every DL2 event.*
| Name | What it is | Its units are set by | Where it shows |
|---|---|---|---|
| **Recorded data** | the mic samples and interval peaks in the event file | nothing: they are raw counts | the event file |
| **Report units** | dB(L) or psi(L) in a report | Blastware's report: the PC's preference (Blastware manual 714U0301 Rev 22 §4, Preferences → Units and Channel). SFM's report: SFM's own fixed choice (PDF PSPL in dB(L), plot in psi) | a Blastware report, an SFM report |
| **Unit peaks** | the peaks the unit works out for its own summary | the unit's Microphone Units setting: psi(L), dB(L) or Pa(L), on the keypad (Right Arrow + Setups) or from Compliance Setup → Special Setups (MiniMate Plus manual 716U0101 Rev 15 §3.9.7) | the unit's screen, Blastware's event list, the 0C record on a live download |
- A Blastware report converts the recorded counts in its PC's preference. That is why DL2's
reports flip dB ↔ psi fleet-wide, in 61 clean runs by report-write time. The decode checker's
`units-is-a-display-preference` carve-out covers it.
- 🔶 **Where the unit stores its own setting, and its unit peaks, is not measured.** Blastware's
event list must read the unit peaks from somewhere, so they are probably in the event file,
perhaps near the embedded event record.
- **To settle it (proposed, not done):** on a bench unit, change Microphone Units on the keypad,
then diff a read-only `1A` read and a short recorded event.
#### D.6.8 Identity, battery and trigger ✅ 2026-11-03
**The identity block** sits before the setup name. It is what the live read gets from SUB FE
(`DeviceInfo`); offsets are from `k`:
| Offset | Content | DL2 |
|---|---|---|
| `k − 202` | serial number, NUL-terminated | 70,042 / 70,042 |
| `k − 193` | firmware minor (`0x11` = 17), as SUB EA | — |
| `k − 190` | battery, uint16 BE, hundredths of a volt | 70,042 / 70,042 (Blastware rounds half up: 6.25 → "6.3 Volts") |
| `k − 147` | firmware, `"S338.17"` | |
| `k − 138` | DSP version, `"10.72"` | Version 70,042 / 70,042 as `V {DSP}-{firmware after "S33"} {model}`; only `10.72-8.17` occurs, so the rule is proven for that alone |
| `k − 132` | calibration date, `dd mm yyyy` (BE year) | Calibration 70,042 / 70,042 as `{Month} {d}, {yyyy} by {k − 128}` |
| `k − 128` | calibrated by, `"Instantel"` | |
| `k − 94` | manufacturer, `"Instantel"` | |
| `k − 72` | model, `"MiniMate Plus"` / `"BlastMate III"` | |
- `k − 180 … k − 149` hold eight float32s (1.0, 8.0, then 1.0s). Not identified.
- 🔶 **Inferred, not measured:** the three bytes before the serial are `9c 06 00`. With the
serial's `B` (0x42) that makes `9c 06 00 42`, the histogram codec's "terminal tail". It looks
like the start of this record rather than the end of a block. Every serial starts with B
(BE… / BA…).
**The trigger source** is in the embedded event record (§7.8.9). The two bytes between its lead
`00 28 05 00` and `fe 80`, a uint16 BE bitmask, were "unknown" until now:
| Value | Blastware's Trigger |
|---|---|
| `0x0001` | Tran |
| `0x0002` | Vert |
| `0x0004` | Long |
| `0x0008` | MicL |
| `0x0200` | Manual |
That holds on 6,524 / 6,524 waveforms.
**Trigger settings,** in Series IV's `0x1A` layout:
| Offset | Content | DL2 |
|---|---|---|
| `k − 19` | trigger sources: `0x07` geophones, `0x08` mic (`0x80` seen once, not identified) | — |
| `k − 23` | active sensors, `0x0f` (all four) | 69,975, `0x07` on 8 mic-less files |
| `k − 31` | stop mode: 0 = Fixed | 6,524 / 6,524, the only value in DL2 |
| channel label + 30 | float32 trigger level: geophones in/s, mic psi | geo 6,484 / 6,484, mic 4,412 / 4,412 |
| MicL + 4 | mic type code: 2 = Linear Weighting, as Series IV | 70,034 / 70,034, the only value |
- **Blastware prints a trigger level only when its channel is a trigger source** and the event
was not Manual.
- **For the mic level in dB, Blastware converts with 6895 Pa per psi.** That gives 4,272 / 4,272;
the exact 6894.757 gives 4,271, failing one boundary case (0.01 psi → "130.8 dB(L)").
- **The file's channel block is the 1A's, 4 bytes earlier.** Compare the 1A's scale constant at
+28 and range at +33 with the file's +24 and +29.
#### D.6.9 Histogram interval detail ✅ 2026-11-03
**Interval size** is a uint16 count of seconds at `k − 40` (Series IV `[8:10]`): 2, 5, 15, 60 or
300. It matches Blastware's IntervalSize ("1 minute", "5 seconds", …) on 63,518 / 63,518 DL2
histograms. **The stop** is the footer's ts2: 63,460 / 63,518. The other 58 are Blastware a
second earlier, the #51 family.
**Each interval's frequency** comes from its half-period in samples:
`frequency = (sample rate / 2) / half-period`. That matches 527,915 / 527,915 printed cells at
1024 sps and 1,725 / 1,725 at 2048.
- ⚠ **RETRACTED (#50):** "frequency = 512 / half-period". 512 is half the sample rate at
1024 sps only; at 2048 sps it halved every frequency.
Blastware prints these words instead of a number, on ~3.1 M DL2 cells:
| half-period / frequency | printed |
|---|---|
| half-period 0 | `N/A` |
| half-period ≤ 5 samples | `>100` at 1024 sps, `>200` at 2048 |
| below 1 Hz | `<1.0` |
| below 10 Hz (20 at 2048) | one decimal |
| otherwise | a whole number |
All four channels match every DL2 histogram.
**Each interval's vector sum** is √PVS² (D.6.5) at the event's range: 63,497 histograms match.
- Blastware prints `OORANGE` for an interval's vector sum above the range when it also clamped
a channel in that interval: 17 / 17 cells. The decode checker's saturation carve-out covers
it.
- 4 cells sit about 4e-6 past a rounding boundary. Blastware's arithmetic is a hair lower; they
stay counted as mismatches.
#### D.6.10 Histogram timing — the histogram's own event record ✅ 2026-11-03 (#51)
**A histogram carries an embedded event record like a waveform's** (§7.8.9):
00 28 05 00 04 00 fe f5 [start 8 B] [stop 8 B]
lead source marker dd mm yyyy 00 hh mm ss (as the footer)
- **Source `04 00`** sits where a waveform's trigger-source bitmask goes (D.6.8).
- **The start is Blastware's Histogram Start Time** on 63,490 / 63,490 DL2 histograms, and the
stop is its Stop Time on 63,490 / 63,490.
- On all 63,500 there is exactly one such record. Its start is 0 or 1 s after the footer's ts1
(1 s on 61,645), and its stop 0 or 1 s before the footer's ts2 (1 s on 57).
- That makes the footer's start a second early on 97%. #51 had read it as SFM's error; it is
the footer's own convention.
**What follows from the start:**
| Field | Blastware's rule | DL2 sample |
|---|---|---|
| Each interval's printed time | its end: start + (i + 1) × interval, capped at the stop | 2,308,524 / 2,308,524 rows |
| Each peak's date and time (Tran, Vert, Long, vector sum, mic) | those of the interval holding its first maximum | 2,000 / 2,000 each |
> ⚠ **RETRACTED 2026-11-03:** "histograms stay on ts1". That held only while SFM's events
> table was unique on (serial, timestamp). A waveform and its histogram share a second in
> Blastware's timing (209 times in prod's 2026-09-30 store). SFM's events are now keyed on
> unit + time + type.
#### D.6.11 Not read from the file yet
*Updated 2026-11-03. 47 of 88 report fields now match on every DL2 event.*
- **Fields not read yet:**
- trigger source and levels, stop mode, mic type, display units, firmware version, serial
number, calibration, battery
- per-interval frequencies (#50: they assume 1024 sps), per-interval PVS, interval size,
histogram stop time
- extended notes
- the values Blastware computes: ZC frequency, acceleration, displacement, time of peak
- sensor check results
- monitor log
- **Open cases:**
- histogram start times are 1 s early (#51)
- about 20 one-minute histograms with a mic peak an interval or two off
- Blastware prints `OORANGE` when the vector sum alone exceeds the range (a carve-out still to
prove)
- Blastware prints `OORANGE` when an event's vector sum alone exceeds the range, with no
clamped channel (a carve-out still to prove; the interval version is proven, D.6.9)
- **Resolved on `dev`, 2026-11-02 → 03:**
- the 37 histograms that decoded wrongly (D.6.1, D.6.5)
- the 26 histogram start dates a day off (D.3.3; 17 of them were the same 5 s files, timed
as waveforms)
- the job number (D.6.3)
- identity, battery, trigger source and trigger settings (D.6.8); Units is Blastware's
preference (D.6.6)
- histogram interval detail: frequencies (#50), vector sums, interval size, stop (D.6.9)
- histogram start, stop, interval and peak times (#51, D.6.10)
---
+42
View File
@@ -1925,6 +1925,15 @@ at `payload[3:5]`:
| 2nd | `0x0002` | 535 B | the file body |
| 3rd | `0x0000` | 11 B | all zeros = **end of file** |
✅ **SFM reads the schedule this way, read-only (2026-11-03, phase 5)** --
`MicromateProtocol.read_file` / `MicromateClient.read_schedule`, frames equal to
THOR's byte for byte (`tests/test_micromate_schedule.py`). Two details the table
above leaves out: the `0x94` request carries **`params[3] = 1`**, and the **first**
`0x48` carries **`params[7] = 1`** (the later ones all-zero params); both `0x48`
offsets are `0xFFFF`. A long file is **written** in 1,024-byte `0x8E` pieces
(the five-entry *actioncheck* schedule went as 1,024 + 280). ⚠ Unmeasured: what
`0x94` / `0x48` return for a unit with no schedule file.
⚠ This is the single most consequential find of the session, because it is not
specific to the scheduler. **`callhome.MMB` is a file too**, and the call-home
config is the last unsolved piece of the project. Reading it should be a
@@ -2736,6 +2745,39 @@ were wrong.
established** — only one setting was varied. Series III's offsets are a starting
hypothesis, not a transfer.
#### Bench 2026-11-04: SFM's first setup push (UM20147)
SFM's audited `POST /device/settings/change`, one send per go (Brian at the
unit). Notes: `~/bench-logs/2026-11-04-sfm-settings/`.
**Measured:**
- **The setup push works as THOR's.** Trigger 0.6 → 0.5, then a five-field
change (Location, Client, job number + its report flag, record time), then a
full restore. Each send was THOR's seven frames, acknowledged in THOR's order
(`25 97 8C 7D 7C 8E 8D`), read back as sent, and confirmed in the unit's menu.
The setup block ended byte for byte as found, CRC included.
- **The unit's recomputed CRC equals SFM's** (`with_crc`): after the first push
the stored block equalled SFM's computed image byte for byte, CRC `ea8d`
included.
- **`schedule.dat` read on a real unit** (`0x94` → `0x6B`; `0x48` → descriptor
`04 00 … 01 … 01`, body, all-zero end). UM20147 holds a leftover THOR
schedule: repeat on, 07:00, start monitoring with
`Fay - Commercial Street - Irish Center.mmb`. The unit runs `test2.MMB`, so
SFM blocked the change, as designed.
- 🔑 **The scheduler On/Off switch is in none of the blocks SFM reads.** With
the keypad switch Off, then On (saved), these were byte for byte identical:
`0x08` prefs, `0x2E`, `0x1A`, `0x2C`, `0x41` and `schedule.dat`. The
firmware's `SysPref.bMonitorScheduler` lives elsewhere. THOR's end-of-push
`0x47` pair (`params[7]` 1 then 3; replies `04 00 … 0N … 00 01`) was only
ever captured with the switch On. **Next:** a THOR bridge recording with the
switch Off (parked for the work-hours project).
- **While monitoring**, a settings preview and a live attempt were both refused
on the run state before any block was read (409, nothing sent, 0 write frames).
- **With call-home off, a stop goes straight to idle** (`monitoring` →
`idle`): no calling-home state and no ring.
- Call-home `0x01` ↔ `0x00` was taken again, both ways. The plan's
"unobserved" warning is retired for those values.
## What the THOR manual settles about the ACH session (2026-09-24)
Source: `manuals/723U0201 THOR Operator Manual Rev 08.pdf` §6.2, §3.6.
@@ -0,0 +1,525 @@
# Phase 5: Changing a Unit's Settings by Serial — Implementation Plan
> **For agentic workers:** REQUIRED SUB-SKILL: Use superpowers:subagent-driven-development (recommended) or superpowers:executing-plans to implement this plan task-by-task. Steps use checkbox (`- [ ]`) syntax for tracking.
**Goal:** An operator edits a unit's live settings in SFM, by serial, on either series: preview old → new, send once (audited), and see what the unit now holds.
**Architecture:**
- **One pure settings codec for both series** (`micromate/setup_fields.py`), on the measured shared 2,090-byte layout.
- **Each series' adapter supplies reads, the plan and the send** to the existing `run_change` core, unchanged.
- Its "state" is a read-back verdict: `as asked` / `unchanged` / `differs`.
- Series 3 sends through `push_config_raw`; Series 4 through `plan_setup_push`.
- Series 4 also reads the unit's schedule, read-only, to refuse a change that a scheduled start would undo.
- **One audited route**, `POST /device/settings/change`. The legacy by-host write is retired.
**Tech Stack:** Python 3 (FastAPI, pytest), vanilla JS tested in Node (`tests/test_webapp_device_routing.py`).
**Spec:** `docs/superpowers/specs/2026-11-03-sfm-phase5-settings-design.md` (approved by Brian 2026-11-03). Parent spec: `docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md`.
## Global Constraints
- **Worktree and branch:** work in `~/seismo-relay-parity` on `feat/series4-sfm-parity`. Check `git branch --show-current` before every commit; never commit to `main`; push every commit.
- **Python:** `/home/serversdown/seismo-relay/.venv/bin/python -m pytest …` from the worktree root.
- **The suite has 16 known failures.**
- Run the full suite once before Task 1 and save the failure list in the plan workspace as `baseline-failures.txt`.
- Before every commit, run the suite, read the failure list, and confirm it equals the baseline.
- Commit in a separate call, never chained to the test run.
- **No live device traffic** in any task. The bench is after the final review, with Brian's explicit go per send.
- Never port 8200.
- Never write modem baud or modem type.
- Never send `0xA2`.
- **`CHANGELOG.md` is not touched** on this branch; it is written on `dev` at the merge.
- **No inline JavaScript.** New page logic goes in `sfm/static/device_routing.js` (DOM-free, Node-tested); glue goes in `sfm/static/sfm_webapp.js`.
- **`docs/instantel_protocol_reference.md` is CRLF.** Edit it only with the Edit tool. Keep its rows in date order.
- **Off-limits (the checker session's files):** `minimateplus/event_file_io.py`, `histogram_codec.py`, `waveform_codec.py`, `bw_xml_report.py`, `decode_check*.py`.
- **`TOOL_VERSION` is unchanged:** nothing here changes event decoding. Operational consequence: none; no migration, no backfill.
- **Grade every protocol claim** in comments and docs as measured or inferred.
- **Mutation checks:** after a mutate/restore, delete the module's `__pycache__/*.pyc` before the confirming run.
## Review Focus
1. **A Micromate with no schedule file, or a schedule read that fails.**
- A body with no records means no conflict, and the change proceeds.
- A read that raises refuses the change in plain words.
- Owner: Task 4; tests `test_no_schedule_records_is_no_conflict` and `test_an_unreadable_schedule_refuses`.
2. **A float that is stored as f32.** 0.3 reads back as 0.30000001192.
- The verdict compares bytes with the image written, never floats, so it reads `as asked`.
- Owner: Task 2; test `test_f32_values_read_back_as_asked`.
3. **A stale or foreign revision** after a keypad edit, or a preview of another unit.
- The send is refused with 409, nothing is sent, and no audit row is written.
- Owner: Tasks 4 and 5; tests `test_s4_stale_revision_sends_nothing` and `test_s3_stale_revision_sends_nothing`.
4. **Range and trigger changed in one request.** The trigger is checked against the **new** range.
- Owner: Task 2; test `test_trigger_checked_against_the_new_range`.
5. **Notes at the edges.**
- `""` clears a note.
- 41 bytes is accepted; 42 is refused; non-ASCII is refused.
- Labels are never written.
- Owner: Task 2; tests `test_note_edges` and `test_note_labels_are_never_written`.
---
## File Structure
| file | responsibility |
|---|---|
| `minimateplus/protocol.py` | **Series 3 assembly:** `assemble_compliance_content`, `is_compliance_content`, `MiniMateProtocol.read_compliance_content`. **Writes:** `push_config_raw`'s pre-check raises `ImageRefused`. |
| `minimateplus/client.py` | **Added:** `read_compliance_content()` and `read_settings_blocks()`. **Deleted:** `apply_config`, `set_project_info`, `_encode_compliance_config`. |
| `micromate/setup_block.py` | **Added:** `with_crc(content)`. |
| `micromate/setup_fields.py` (new) | **The shared, pure settings codec:** field registry, `editable_fields`, `check_changes`, `encode_setup`, `field_values`, `settings_state`, `revision`. |
| `micromate/schedule.py` (new) | **Pure:** `parse_schedule`, `ScheduleEntry`, `schedule_conflicts`. |
| `micromate/protocol.py` | **Added:** `read_file(path)`, using `0x94` then `0x48` pages. |
| `micromate/client.py` | **Added:** `read_schedule()`, `get_active_setup_raw()`, `get_prefs_content()`, `get_trigger_content()`, `get_setup_content()`. |
| `micromate/opcodes.py` | `ENABLEABLE_WRITES` gains the setup-push SUBs. |
| `sfm/device_access/errors.py` | **Added:** `SettingsChanged` and `ChangeRefused`, both 409. |
| `sfm/device_access/change.py` | **Added:** `settings_change()`. |
| `sfm/device_access/s4.py` | `s4_settings` moves onto the codec. **Added:** `s4_change_settings`. |
| `sfm/device_access/s3.py` | `Series3Adapter.settings` moves onto the codec. **Added:** `Series3Adapter.change_settings`. |
| `sfm/device_access/access.py` | **Added:** `DeviceAccess.change_settings`. |
| `sfm/server.py` | **Added:** `POST /device/settings/change`. `/device/config` and `/device/config/project` return 410. |
| `sfm/static/device_routing.js`, `sfm/static/sfm_webapp.js`, `sfm/sfm_webapp.html` | The edit form. |
| `tests/device_access_fakes.py` | The fakes gain settings blocks, a schedule, and writes. |
---
### Task 1: Series 3 — assemble a settings read into the logical block
**Measured basis (spec, 2026-11-03):** unescape each `1A` data frame and take `data[11:]`. Every frame but the last starts with one non-content `00` byte; drop it. The result is 2,090 bytes with `N = 2090` at `[0:2]`.
**Files:**
- Modify: `minimateplus/protocol.py`, near `read_compliance_config` (≈ line 913)
- Modify: `minimateplus/client.py`
- Modify: `docs/instantel_protocol_reference.md` (one dated row, 2026-11-03)
- Test: `tests/test_s3_settings_read.py` (new)
**Interfaces:**
- Produces:
- `assemble_compliance_content(frames: list[bytes]) -> bytes`. `frames` is each data reply's `frame.data`, escapes kept, in order.
- `is_compliance_content(block: bytes) -> bool`: `len == 2090` and `int.from_bytes(block[0:2], "big") == 2090`.
- `COMPLIANCE_CONTENT_LEN = 2090`.
- `MiniMateProtocol.read_compliance_content() -> bytes`:
- sends the same probe and B/C/D requests as `read_compliance_config`;
- a missing data frame raises `ProtocolError` (no `continue`);
- returns the assembled bytes **without** judging them, so a monitoring unit's device-info answer comes back for the caller to recognise.
- `MiniMateClient.read_compliance_content() -> bytes`.
- `MiniMateClient.read_settings_blocks() -> dict` with keys `event_index`, `compliance`, `trigger` and `waveform`. Each value is the bytes its existing read returns:
- `event_index`: `proto.read_event_index()`
- `compliance`: `read_compliance_content()`
- `trigger`: `proto.read_trigger_config()`
- `waveform`: `proto.read_waveform_data_raw()`
- [ ] **Step 1: Write the failing tests** in `tests/test_s3_settings_read.py`. Use `tests/fixtures/minimate-bench-10-26-26-histogram` (`unit_replies.bin` parsed with `S3FrameParser`). Group the `0xE5` frames into reads: a frame with `len(data) == 11` starts each read. Take the write images from `tests/test_minimate_write_frames.py` (`WRITES[0:13]`, `WRITES[13:26]`; the `0x71` payloads `[16:]` joined).
```python
def test_reads_assemble_to_2090_bytes(): # all 12 reads, both frame patterns (5 and 3 frames)
assert all(len(assemble_compliance_content(r)) == 2090 for r in READS)
def test_a_read_after_a_blastware_write_equals_the_write():
assert assemble_compliance_content(READS[1]) == IMAGES[0][:2090]
assert assemble_compliance_content(READS[2]) == IMAGES[1][:2090]
def test_a_monitoring_units_answer_is_not_settings(): # READS[3:8] start 0e 'BE9441'
assert [is_compliance_content(assemble_compliance_content(r)) for r in READS[3:8]] == [False] * 5
assert all(is_compliance_content(assemble_compliance_content(r)) for r in READS[:3] + READS[8:])
def test_read_compliance_content_refuses_a_missing_frame():
... # a fake transport that answers the probe and frame B, then times out: ProtocolError, nothing assembled
```
- [ ] **Step 2: Run them.** `…pytest tests/test_s3_settings_read.py -q`. Expected: FAIL (ImportError: `assemble_compliance_content`).
- [ ] **Step 3: Implement** the Produces block in `protocol.py` and `client.py`. Use `unescape_reply` from `minimateplus.framing`. The docstring cites the measurement and its fixture.
- [ ] **Step 4: Run them.** Expected: PASS (4 passed).
- [ ] **Step 5: Add a reference row** to `docs/instantel_protocol_reference.md` (Edit tool; CRLF), dated 2026-11-03, measured. Cover:
- the assembly rule;
- the round trip (2 of 2);
- `[26:28]`: Blastware writes `00 00` (11 of 11), and the unit sets `01 7f` after monitoring;
- the trailing two bytes: a per-unit Blastware constant (`7c ea` BE11529 ×9, `0c e9` BE9441 ×2), not the CRC, and never in a reply;
- `0x09 [200:202]`: echoed 9 of 9 in April; changed on 10-26 (`17 17` → `78 76`).
- [ ] **Step 6: Run the full suite** and compare the failure list with the baseline. **Then commit** (separate call): `feat(s3): assemble a settings read into the 2,090-byte block`.
---
### Task 2: The shared settings codec
**Files:**
- Create: `micromate/setup_fields.py`
- Modify: `micromate/setup_block.py`: add `with_crc(content: bytes) -> bytes`, which returns the content with `CRC-16/AUG-CCITT` over `[0:N-2]` written BE at `[N:N+2]`.
- Test: `tests/test_setup_fields.py` (new)
**Interfaces:**
- Consumes: Task 1's `assemble_compliance_content`, used in tests only. The codec itself imports nothing from `minimateplus` and nothing from `sfm`.
- Produces (all pure). Each `content` is the 2,090-byte (Series 3) or 2,092-byte (Series 4) block.
- `editable_fields(content: bytes, series: int) -> list[dict]`. Each dict has `field`, `label`, `kind` (`"number"`, `"choice"`, `"text"` or `"bool"`) and `value`, plus as relevant `unit`, `min`, `max`, `choices` (a list of `{value, label}`) and `maxlength`.
- `field_values(content: bytes, series: int) -> dict[str, Any]`: the same fields, values only.
- `check_changes(content: bytes, series: int, changes: dict) -> dict`: returns the normalised changes, or raises `SettingsValueError(ValueError)` with a plain sentence. It has two kinds of check: static (names, types, choices, limits) and content-dependent (unit strings, the trigger against the range).
- `encode_setup(content: bytes, series: int, changes: dict) -> bytes`:
- same length as `content`;
- only the changed fields' bytes move;
- bit fields are patched bit by bit;
- Series 3 also sets `[26:28] = 00 00` (`S3_BLASTWARE_FIXED`);
- Series 4 returns `with_crc(...)`.
- `settings_state(before: bytes, written: bytes, now: bytes, *, series: int) -> str`. It compares `[0:2090]`:
- `"as asked"` if `now` equals `written` (Series 4 also needs `crc_ok(now)`);
- else `"unchanged"` if `now` equals `before`;
- else `"differs"`.
- `revision(blocks: list[bytes]) -> str` = `hashlib.sha256(b"".join(blocks)).hexdigest()[:16]`.
- `S3_ALARM_WRITE_MEASURED = False`. While False, `geo_alarm_ips` is shown (read-only, `kind` plus `"readonly": True`) and refused in `check_changes`.
**The field registry** (content offsets; channel `k` = `1708 + 48·k`, `k` = 0, 1, 2 for the geophones):
| field | series | bytes | values (exact) |
|---|---|---|---|
| `record_mode` | 3 | `[5]` | `single_shot`=0, `continuous`=1, `histogram`=3, `histogram_continuous`=4 |
| `record_mode` | 4 | `[5]` | `waveform`=1, `manual`=2, `histogram`=3, `combo`=4 |
| `sample_rate` | 3, 4 | `[6:8]` u16 BE | {1024, 2048, 4096} |
| `histogram_interval_s` | 3, 4 | `[8:10]` u16 BE | {2, 5, 15, 60, 300, 900} |
| `record_time_s` | 3 | `[18:22]` f32 BE | 1.0 ≤ v ≤ `S3_MAX_RECORD_S[sample_rate]` = {1024: 104, 2048: 52, 4096: 26}, and ≤ 13 when `record_mode` is `histogram_continuous` (the **new** mode and rate if they change too) |
| `record_time_s` | 4 | `[18:22]` f32 BE | 1.0 ≤ v ≤ 90.0 |
| `geo_trigger_ips` | 3, 4 | ch k `+30` f32 BE, all three | 0.005 ≤ v ≤ 10.0, a multiple of 0.001 (within 1e-9), and ≤ the (new) range's full scale (10.0 / 1.25) |
| `geo_range` | 3 | ch k `+29` u8, all three | `normal`=0, `sensitive`=1 |
| `geo_alarm_ips` | 3 (gated) | ch k `+38` f32 BE, all three | 0.005 ≤ v ≤ full scale |
| `job_number` | 3, 4 | `[40:42]` u16 BE | 1 ≤ v ≤ 9999 |
| `job_number_shown` | 3, 4 | `[39]` bit `0x02` | bool |
| `note_1` … `note_4` | 3, 4 | value `[144+64n : 186+64n]`; label `[122+64n : 144+64n]` read only | printable ASCII 0x20–0x7E, ≤ 41 bytes, zero-filled to 42 |
The limits are **the units' own, from Instantel's manuals** (Brian, 2026-11-03), cited in the module as comments:
- **Trigger** 0.005–10 in/s, steps of 0.001: MiniMate Plus manual 716U0101 Rev 15, Appendix *Series III Specifications*; Micromate manual 721U0201 Rev 06, *Geophone Trigger Level*.
- **Record time:**
- Micromate 1–90 s (*Record Time*).
- MiniMate: §4.4's *Maximum Record Times*, 1 MB unit, channels 1–4; §3.8.9, 13 s in Histogram Combo.
- **Job number** 1–9999: both manuals.
**A level write is refused** unless all three geophone channels' unit string, `ch +34:+38` with NULs and `.` stripped, equals `in`. Measured: `in.` and `in` both occur on UM20147. A unit set to Metric is unmeasured.
- [ ] **Step 1: Write the failing tests** in `tests/test_setup_fields.py`:
```python
def test_s3_reproduces_every_blastware_write():
# BE11529's 9 April images (bridges/captures/4-20-26/**/raw_bw_*.bin), in time order (the HHMMSS in
# the name): before = the previous image; the first (151921) uses the assembled 1A read in its own
# raw_s3 capture if that read is whole, else it is skipped (say so in the test). BE9441's 2 images:
# before = the assembled READS[0], then image 1. changes = field_values(after) for every field whose
# value differs. Assert encode_setup(before, 3, changes)[:2090] == after[:2090].
# The 16:26 write also moves [25] (mic on): include `_sensors_mic` as a test-only patch helper,
# not a registry field.
def test_s4_fixture_pairs_reproduce():
# for every ordered pair (a, b) of tests/fixtures/micromate-setup/*.bin whose differing bytes outside
# [2090:2092] all lie inside registry fields: encode_setup(a, 4, {f: field_values(b)[f] for differing f}) == b
def test_trigger_checked_against_the_new_range(): ... # Series 3: {"geo_range": "sensitive", "geo_trigger_ips": 2.0} refuses (above 1.25); 1.25 passes; {"geo_trigger_ips": 2.0} alone on Normal passes
def test_limits_refuse_outside_values(): ... # 0.004 and 10.001 in/s; 0.3005 (not a 0.001 step); job 0 and 10000; S4 0.9 and 90.1 s;
# S3 at 4096 sps: 26 ok, 26.1 refused; S3 histogram_continuous: 13 ok, 13.1 refused;
# S3 {"sample_rate": 1024, "record_time_s": 100} passes from a 4096 sps block (the new rate counts);
# sample rate 8192; interval 30
def test_field_not_offered_for_the_series(): ... # geo_range on series 4 -> SettingsValueError naming the series
def test_alarm_is_read_only_until_measured(): ... # Series 3 geo_alarm_ips -> SettingsValueError while S3_ALARM_WRITE_MEASURED is False
def test_metric_unit_string_refuses_level_writes(): ... # ch +34 = b"mm\x00\x00" -> SettingsValueError; b"in.\x00" and b"in\x00\x00" pass
def test_note_edges(): ... # "" clears; 41 bytes ok; 42 refused; "café" refused
def test_note_labels_are_never_written(): ... # changing note_2 moves only [208:250]
def test_bit_fields_keep_unknown_bits(): ... # [39] = 0x81: job_number_shown True -> 0x83, False -> 0x81
def test_s3_fixed_bytes(): ... # any S3 encode sets [26:28] = 00 00
def test_s4_encode_recomputes_the_crc(): ... # crc_ok(encode_setup(fixture, 4, {"job_number": 7}))
def test_f32_values_read_back_as_asked(): ... # written = encode(0.3); settings_state(before, written, written) == "as asked"
def test_settings_state(): ... # "as asked" / "unchanged" / "differs"; S4 with a bad CRC -> "differs"
def test_revision_is_stable_and_content_sensitive(): ...
```
- [ ] **Step 2: Run them.** Expected: FAIL (ModuleNotFoundError: `micromate.setup_fields`).
- [ ] **Step 3: Implement** `micromate/setup_fields.py` and `with_crc`. Decode via the registry (not via `decode_setup`, whose notes are keyed by label). Note labels come from the unit and are display only.
- [ ] **Step 4: Run them.** Expected: PASS. Then mutation-check `S3_BLASTWARE_FIXED` (remove it: the Blastware-write test fails), delete the `.pyc`, and restore.
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(codec): one settings codec for both series, on the shared layout`.
---
### Task 3: Micromate — read the schedule file
**Measured basis:** reference *The scheduler, and a generic file transfer* and *The schedule record format*.
- `0x94 <path>` opens a file for read; `offset` = the path's length, and the payload is the path, unpadded.
- `0x48` reads the next page, repeated until an all-zero 11-byte response.
- The file is 260-byte records. `[4]` is the half-hour slot. `[6]` is the action bitmask: 2 start-with-setup, 4 stop, 8 self-check, 16 ACH. `[7]` is the name length; `[8:260]` is the name.
**Files:**
- Create: `micromate/schedule.py`
- Modify: `micromate/protocol.py` (`read_file`), `micromate/client.py`
- Modify: `docs/micromate_protocol_reference.md`: one line under the scheduler section saying SFM reads it (read-only) from 2026-11-03.
- Test: `tests/test_micromate_schedule.py` (new)
**Interfaces:**
- Produces:
- `SCHEDULE_PATH = "\\system\\schedule\\schedule.dat"`.
- `MicromateProtocol.read_file(path: str) -> bytes`: the concatenated content of each `0x48` page after the page-0 descriptor, stopping at the all-zero response; at most 64 pages, else `ProtocolError`.
- `MicromateClient.read_schedule() -> bytes`.
- `MicromateClient.get_active_setup_raw() -> str`: the `0x41` name up to its NUL, **not** stripped.
- `MicromateClient.get_prefs_content() -> bytes` (`0x08`), `get_trigger_content() -> bytes` (`0x2E`) and `get_setup_content() -> bytes` (`0x1A`), each `_content(...)` of its read.
- `@dataclass(frozen=True) class ScheduleEntry`: `index: int`, `time: str` (`"HH:MM"`), `day: int`, `action_bits: int`, `actions: tuple[str, ...]`, `setup: str`.
- `parse_schedule(body: bytes) -> list[ScheduleEntry]`: 260-byte records; a record with `[4:8]` all zero and no name ends the list. `actions` names the bits 2/4/8/16 as `start_with_setup`, `stop`, `self_check` and `call_home`; any other bit becomes `unknown(0xNN)`.
- `schedule_conflicts(entries, active_setup: str) -> list[ScheduleEntry]`: start entries whose setup, compared case-insensitively after `strip()`, is not the active setup.
- [ ] **Step 1: Write the failing tests.** Parse the bodies from `bridges/captures/9-24-26 - micromate2/raw_s3_20260924_191835_read_scheduler.bin` (frames 0–4), and from the two `raw_*_20260925_*` captures, with `MicromateFrameParser`.
```python
def test_the_read_capture_parses(): # 2 records: start-with-setup 07:30 (40-char name), call_home 19:30 (no name)
def test_the_five_entry_schedule_parses(): # 07:30 start TEST1.mmb, 08:00 stop, 08:30 self_check, 09:00 start test2.mmb, 19:30 call_home
def test_conflicts_are_case_insensitive(): # active "test1.MMB" -> only the test2.mmb start conflicts
def test_no_schedule_records_is_no_conflict(): assert schedule_conflicts(parse_schedule(bytes(524)), "x.mmb") == []
def test_read_file_sends_the_path_unpadded_and_stops_at_zeros(): ... # a fake protocol: 0x94 offset 0x001D, then 0x48 until all-zero
def test_get_active_setup_raw_keeps_spaces(): ... # " LOC 4 .mmb " survives
```
- [ ] **Step 2: Run them.** Expected: FAIL (ModuleNotFoundError: `micromate.schedule`).
- [ ] **Step 3: Implement** the Produces block. `read_file` builds `0x94` with `build_request(0x94, len(path), bytes(10), path.encode("ascii"))`. Both SUBs are already in `READ_SUBS`.
- [ ] **Step 4: Run them.** Expected: PASS.
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(micromate): read the schedule file (read-only)`.
---
### Task 4: Change-path pieces and the Series 4 settings change
**Files:**
- Modify: `sfm/device_access/errors.py`, `sfm/device_access/change.py`, `micromate/opcodes.py`, `sfm/device_access/s4.py`, `tests/device_access_fakes.py`
- Modify: `tests/test_micromate_execute.py`, `tests/test_micromate_opcodes.py`. Their over-ceiling example `0x71` becomes enableable here; use `0xA8` (delete one event) instead.
- Test: `tests/test_device_access_s4_settings.py` (new)
**Interfaces:**
- Consumes:
- Task 2: `editable_fields`, `field_values`, `check_changes`, `encode_setup`, `settings_state`, `revision`.
- Task 3: `read_schedule`, `parse_schedule`, `schedule_conflicts`, `get_active_setup_raw`, and the content getters.
- `micromate.writes.plan_setup_push(prefs, trigger, setup, name)`.
- Produces:
- `class SettingsChanged(DeviceError)`, `http_status = 409`.
- `class ChangeRefused(DeviceError)`, `http_status = 409`.
- `settings_change() -> ChangeKind("change settings", "as asked", "applied")`.
- `ENABLEABLE_WRITES = frozenset({0x96, 0x97, 0x7E, 0x7F, 0xDA, 0x68, 0x73, 0x82, 0x83, 0x71, 0x72})`.
- `s4_settings(client, serial) -> UnitSettings`. It keeps every current field, plus `detail["editable"] = editable_fields(setup, 4)`. The revision comes only from a preview (dry run), never from this read.
- `s4_change_settings(client, serial, *, changes: dict, revision: Optional[str], dry_run: bool, audit, address, caller, sleep, verify_timeout_s, verify_interval_s) -> ChangeResult`.
**`s4_change_settings` behaviour**, through `run_change` (`even_if_already=False`):
- **`read_state`, first call:**
- Read the run state.
- `calling_home` and `unknown*` are returned as they are.
- `monitoring` raises `UnitStateUnknown(f"{serial} is monitoring -- stop it first (a stop makes it call in if call-home is on) -- nothing sent")`.
- Read the name (raw), prefs, trigger and setup.
- `check_changes` (a `SettingsValueError` becomes `BadRequest`).
- When live, `revision([name.encode("ascii"), prefs, trigger, setup])` must equal the request's. Otherwise raise `SettingsChanged("the unit's settings changed since the preview -- preview again; nothing sent")`.
- `image = encode_setup(setup, 4, changes)`.
- Read the schedule; a read error is kept as a blocking reason.
- Return `settings_state(setup, image, setup, series=4)`.
- **Later calls:** read the setup and return `settings_state(before, image, now, series=4)`.
- **`describe_plan`:**
- `plan_setup_push(prefs, trigger, image, name).describe()`, plus `fields` = `{f: {label, old, new}}` for the changed fields, `revision`, `warnings` and `blocked`.
- `warnings` always includes: "this reads the unit's keypad edit buffer: if someone is in its menu, their unsaved edits are sent too".
- `blocked`:
- the name is `factory.MMB` (case-insensitive): "this unit is running its factory setup; load any other setup on its keypad, then try again";
- each schedule conflict: "this unit's schedule loads <setup> at <HH:MM>, which would replace this change";
- a schedule read error: "could not read this unit's schedule (<error>) -- SFM will not change a unit whose schedule it cannot check";
- `plan_setup_push` raising `ValueError` (a block size or header THOR's offsets were never seen at, or a failed checksum): "this unit's <message> -- SFM has not seen a block like it".
- When `blocked` is non-empty, `steps` is `[]`, and a live call raises `ChangeRefused("; ".join(blocked) + " -- nothing sent")`.
- When the schedule names the active setup, `warnings` adds: "the unit's schedule loads this setup at <HH:MM>; the change survives it".
- **`send`:** `client.protocol.execute(plan)`, as `s4_change_call_home` does.
- **`snapshot`:**
- `fields`: `{f: {label, old, new, now}}`;
- `before` / `after` hex of the setup;
- `changed_offsets`;
- `prefs` and `trigger`: before hex only.
- **`is_refusal`**, **`is_ring`** and **`pre_send`**: as in `s4_change_call_home`.
**Validation order:** a live call without `revision` is refused before any I/O, in Task 6's `DeviceAccess` (not here).
- [ ] **Step 1: Write the failing tests.** Extend `FakeMicromateClient` with:
- `setup` (default: `tests/fixtures/micromate-setup/um20147_baseline.bin`'s last 2,092 bytes);
- `prefs`, `trigger` and `active_name` (default `"test2.mmb"`);
- `schedule_body` (default `bytes(524)`) and `schedule_error`;
- `execute` applies a setup-push plan's `0x71` data to `self.setup` (re-adding the CRC with `with_crc`), so a read-back sees it.
```python
def test_s4_dry_run_previews_old_to_new_and_sends_nothing(): # fields == {"geo_trigger_ips": {"label": ..., "old": 0.5, "new": 0.3}}; revision present; fake.executed == []
def test_s4_trigger_change_sends_the_push_and_verifies(): # subs [0xDA,0x68,0x73,0x82,0x83,0x71,0x72]; outcome sent/ok; state_after "as asked"
def test_s4_stale_revision_sends_nothing(): # SettingsChanged; fake.executed == []; audit has no rows
def test_s4_already_as_asked_is_skipped(): # outcome skipped, nothing executed
def test_s4_monitoring_is_refused(dry_run in (True, False)): # "stop it first" and "nothing sent"
def test_s4_factory_setup_is_refused_live_and_shown_in_preview():
def test_s4_schedule_conflict_blocks(): # schedule starts "other.mmb" at 07:00 -> ChangeRefused naming other.mmb and 07:00
def test_s4_schedule_on_the_active_setup_warns_only():
def test_an_unreadable_schedule_refuses():
def test_no_schedule_records_is_no_conflict(): # bytes(524) -> sent
def test_s4_a_lost_ack_records_what_the_unit_holds(): # execute_error -> outcome failed, sent True, snapshot present
def test_s4_unseen_block_size_is_blocked(): # prefs 91 B -> preview blocked; live ChangeRefused; nothing executed
def test_setup_push_subs_are_now_enableable():
```
- [ ] **Step 2: Run them.** Expected: FAIL (ImportError: `s4_change_settings`).
- [ ] **Step 3: Implement** the Produces block and update `s4_settings`. In the two opcode tests, swap the over-ceiling example to `0xA8`.
- [ ] **Step 4: Run them**, plus `tests/test_micromate_execute.py`, `tests/test_micromate_opcodes.py`, `tests/test_micromate_writes.py` (THOR's setup-push frames still reproduce) and `tests/test_device_access_s4_call_home.py`. Expected: PASS.
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(s4): change a Micromate's settings by serial, audited, schedule-checked`.
---
### Task 5: The Series 3 settings change
**Files:**
- Modify: `sfm/device_access/s3.py`, `minimateplus/client.py` (`push_config_raw` pre-check), `tests/device_access_fakes.py`
- Test: `tests/test_device_access_s3_settings.py` (new)
**Interfaces:**
- Consumes:
- Task 1: `read_compliance_content`, `read_settings_blocks`, `is_compliance_content`.
- Task 2: the codec.
- Task 4: `settings_change`, `SettingsChanged`, `ChangeRefused`.
- `MiniMateClient.push_config_raw(event_index, compliance, trigger, waveform)`.
- Produces:
- `push_config_raw` raises `ImageRefused` (from `minimateplus.protocol`) when its pre-check refuses a block, before any frame.
- `Series3Adapter.settings(address, serial) -> UnitSettings`. It is built on `read_compliance_content` and the codec, with the same top-level fields as today, plus `detail["editable"]`. A non-settings answer raises `UnitStateUnknown(S3_SETTINGS_WHILE_MONITORING)`.
- `S3_SETTINGS_WHILE_MONITORING = "did not return its settings -- a MiniMate answers this way while monitoring; stop monitoring first"`.
- `Series3Adapter.change_settings(address, serial, *, changes, revision, dry_run, audit, caller, sleep, verify_timeout_s, verify_interval_s) -> ChangeResult`, through `run_change` and `self._run(address, op, retry=False)`:
- `read_serial`: `client.connect().serial`.
- **`read_state`, first call:**
- Wake, then `read_settings_blocks()`.
- A non-settings `compliance` raises `UnitStateUnknown(f"{serial} {S3_SETTINGS_WHILE_MONITORING} -- nothing sent")`.
- `check_changes`, and the live revision check over `[event_index, compliance, trigger, waveform]`.
- Compute `image = encode_setup(...)` and return `settings_state(...)`.
- **Later calls:** wake, `read_compliance_content()`, then the verdict.
- **`describe_plan`:**
- `steps` in Blastware's order: 68 (event index, as read), 73, 71 (settings block, 2,092 B), 72, 82 (trigger, as read), 83, 69 (waveform data, as read), 74, 72. Each step has `sub`, `what` and `data_len`.
- `fields`, `revision` and `warnings` as Series 4. The warning: "the two bytes after the settings block go out as 00 00 (Blastware sends its own constant; effect unmeasured)".
- **`send`:** `client.push_config_raw(event_index, image, trigger, waveform)`.
- **`is_refusal`:** `isinstance(e, ImageRefused)`.
- **`snapshot`:** as Series 4, without prefs and trigger.
- [ ] **Step 1: Write the failing tests.** Extend `FakeMiniMateClient` with:
- `settings_blocks`: the default compliance is BE9441's assembled 10-26 read 2; `event_index`, `trigger` and `waveform` are the `0x68`, `0x82` and `0x69` payloads (`[16:]`) of `WRITES[13:26]` in `tests/test_minimate_write_frames.py`, each minus its two trailing bytes (a write is the read plus two);
- `push_config_raw` records its four arguments and makes the compliance the new `read_compliance_content`;
- `monitoring_settings=True` returns a device-info-shaped block.
```python
def test_s3_settings_read_uses_the_codec(): # editable includes geo_range; record_mode "histogram"; notes by slot with unit labels
def test_s3_dry_run_previews_and_sends_nothing():
def test_s3_trigger_change_sends_the_units_own_blocks(): # push args: event_index/trigger/waveform == the read blocks; compliance == encode_setup(...)
def test_s3_change_verifies_by_read_back(): # outcome sent/ok, state_after "as asked", snapshot fields old/new/now
def test_s3_stale_revision_sends_nothing():
def test_s3_monitoring_is_refused(dry_run in (True, False)):
def test_s3_a_refused_image_is_audited_as_nothing_sent(): # push_config_raw raises ImageRefused -> row sent 0, "refused before sending"
def test_push_config_raw_precheck_raises_image_refused(): # a 2,089-byte compliance block -> ImageRefused, no frame written
```
- [ ] **Step 2: Run them.** Expected: FAIL (AttributeError: `change_settings`).
- [ ] **Step 3: Implement** the Produces block.
- [ ] **Step 4: Run them**, plus `tests/test_s3_call_home.py`, `tests/test_minimate_write_frames.py` and `tests/test_device_access_*`. Expected: PASS, except the tests Task 6 deletes or rewrites. If one fails here only because it pins `apply_config`, leave it for Task 6 and note that in the ledger.
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(s3): change a MiniMate's settings by serial on the shared codec`.
---
### Task 6: Device access, the route, and retiring the legacy write
**Files:**
- Modify: `sfm/device_access/access.py`, `sfm/server.py`, `minimateplus/client.py`
- Delete: `poc_set_project.py`. Remove `exp_compliance_only` (and its registration) from `experiments.py`.
- **Ruling (spec: "the legacy write is retired"):** both write a live unit through the retired encoder, which #46 found wrong. Git keeps them.
- Modify tests:
- `tests/test_s3_compliance_anchor_fields.py`: remove its write-side tests (the encoder is gone).
- `tests/test_minimate_write_frames.py`: `test_apply_config_writes_the_units_own_trigger_block` moves to Task 5's `test_s3_trigger_change_sends_the_units_own_blocks`; delete it here.
- `tests/test_server_series3_guard.py`: drop `apply_config` from `WRITES` and its fake method.
- `tests/test_server_device_access.py`: `/device/config` now 410.
- Test: `tests/test_device_access_settings.py` (new), `tests/test_server_settings_change.py` (new)
**Interfaces:**
- Consumes: Task 4's `s4_change_settings` and Task 5's `Series3Adapter.change_settings`.
- Produces:
- `DeviceAccess.change_settings(address, serial, *, changes: dict, revision: Optional[str], dry_run: bool = False, caller: str = "api") -> ChangeResult`:
- `normalise_serial`, then `series_for_serial`;
- `changes` must be a non-empty dict, else `BadRequest`;
- a live call without `revision` raises `BadRequest("preview first: a live change needs the revision from its preview -- nothing sent")`;
- a live call with no audit log raises `NotSupported` (as `set_call_home`);
- `_dispatch(..., change=True)` with `verify_timeout_s=_SETTINGS_VERIFY_TIMEOUT_S = 2.0` and `verify_interval_s=_SETTINGS_VERIFY_INTERVAL_S = 1.0`.
- `POST /device/settings/change`:
- query: `serial` (required), `host`, `tcp_port`, `port`, `baud`, `dry_run`, `caller`;
- JSON body `{"changes": {...}, "revision": "..."}`;
- returns `_change_response(...)`;
- added to `_SERIAL_AWARE_PATHS`.
- `POST /device/config` and `POST /device/config/project` return **410** with `{"detail": "retired: change a unit's settings by serial with POST /device/settings/change (audited, previewed, read back)"}`. Remove the cache-dirty hooks that only these routes called; keep the read routes.
- Delete `MiniMateClient.apply_config`, `set_project_info` and `_encode_compliance_config`, and any import left orphaned.
- [ ] **Step 1: Write the failing tests:**
```python
def test_live_change_without_revision_is_refused_before_io(): # factory never called
def test_empty_changes_is_a_bad_request():
def test_change_settings_dispatches_by_series_with_change_true():
def test_route_dry_run_returns_fields_and_revision(): # 200, body.plan.fields, body.plan.revision
def test_route_verified_change_is_200_and_mismatch_409():
def test_route_unconfirmed_carries_sent_and_audit_id():
def test_route_refusal_is_409_with_reason(): # ChangeRefused / SettingsChanged / monitoring
def test_legacy_config_routes_are_gone(): # both 410, nothing reaches a client factory
def test_settings_change_is_serial_aware(): # in _SERIAL_AWARE_PATHS; a UM serial goes to the Series-4 path
```
- [ ] **Step 2: Run them.** Expected: FAIL (404 / AttributeError).
- [ ] **Step 3: Implement** the Produces block, the deletions, and the test updates listed under Files.
- [ ] **Step 4: Run them**, plus `tests/test_server_*.py`. Expected: PASS. Check that `grep -rn "apply_config\|set_project_info\|_encode_compliance_config" --include=*.py .` finds only comments and history.
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(sfm): POST /device/settings/change; retire the legacy config write`.
---
### Task 7: The page — edit, preview, send, "the unit now holds"
**Files:**
- Modify: `sfm/static/device_routing.js`, `sfm/static/sfm_webapp.js`, `sfm/sfm_webapp.html`
- Modify: `CLAUDE.md` (the "Where things stand" Series-4 parity line: phase 5 built, bench pending), and the spec's status line ("Built 2026-11-xx; bench pending").
- Test: `tests/test_webapp_device_routing.py` (extend `EXPORTS` and cases), `tests/test_webapp_static.py`
**Interfaces:**
- Consumes: `UnitSettings.detail.editable` / `.revision`, and the `ChangeResult` shapes from Tasks 4–6.
- Produces (DOM-free, in `device_routing.js`):
- `DEVICE_ROUTES.settings_change = ['POST', '/device/settings/change', true]`; remove `config_write`.
- `controlsFor(unit)`: `configWrite: serialMode && (series === 3 || series === 4)`; `reasons.configWrite: 'By serial only: Preview, then Send (audited).'`
- `settingsFormFields(st) -> Array<{field, label, kind, value, unit?, min?, max?, choices?, maxlength?, readonly?}>`: from `st.detail.editable`, in that order.
- `settingsChanges(fields, edited) -> object`: only fields whose edited value differs. Numbers compare as numbers; read-only fields are ignored.
- `settingsPreviewRows(body) -> Array<[label, old, new]>`, from `body.plan.fields`.
- `settingsBlockedText(body) -> string`: `body.plan.blocked` joined; `''` if none.
- `settingsResultRows(body) -> Array<[label, old, new, now]>`, from `body.detail.snapshot.fields`.
- **Page behaviour** (`sfm_webapp.js` glue; HTML ids `cfg-edit`, `cfg-preview-btn`, `cfg-send-btn`, `cfg-preview`, `cfg-result`):
- The serial-mode Config pane heading reads **"On the unit <SERIAL> — read <HH:MM>"**.
- The form is built from `settingsFormFields`.
- **Preview** POSTs a dry run and shows old → new, warnings and blocked reasons. It keeps `revision` and enables **Send** only when nothing is blocked and something changes.
- **Send** asks `confirm()` naming the serial and the fields, then POSTs live with the kept revision and shows "the unit now holds" rows. Errors go through `changeErrorText`.
- Editing any field after a preview disables **Send** until the next preview.
- The by-host legacy form loses its write button. Its read stays.
- No inline script; listeners via `addEventListener`.
- [ ] **Step 1: Write the failing Node-run cases** in `tests/test_webapp_device_routing.py`:
- `controlsFor` gives `configWrite` true by serial for both series, and false by host;
- `settingsChanges` returns only differing fields and compares `0.30` with `0.3` as equal;
- `settingsPreviewRows` / `settingsResultRows` / `settingsBlockedText` on bodies shaped as Task 6 returns them;
- `deviceUrl('settings_change', unit)` → `/device/settings/change?serial=…`;
- `config_write` is no longer a route.
In `tests/test_webapp_static.py`, assert the page has no inline `<script>` body and loads both static files.
- [ ] **Step 2: Run them.** `…pytest tests/test_webapp_device_routing.py tests/test_webapp_static.py -q`. Expected: FAIL (`settingsChanges` is not a function).
- [ ] **Step 3: Implement** the Produces block and the page behaviour.
- [ ] **Step 4: Run them.** Expected: PASS. Then run the page under the jsdom harness pattern from phase 4 (`smoke/page_files_load.js` in the scratchpad): the page loads with no console error, and a stubbed dry-run body renders the preview rows.
- [ ] **Step 5: Update `CLAUDE.md`** and the spec status line. **Run the full suite** and compare with the baseline. **Commit:** `feat(webapp): edit a unit's settings by serial: preview, send, read back`.
---
## After the build: final review, then the bench
The bench is not a task: it runs after the whole-branch review and its fixes, with Brian at the units, and **each send needs his explicit go**. Run SFM with `ringkit/sfm_parity.py` (port 8299; never 8200). Order:
1. **Read-only, both units:**
- `GET /device/settings` by serial; Brian matches it against each unit's screen.
- UM20147: `read_schedule` (measure what a unit with no schedule answers, and whether `0x08` shows the scheduler switch).
2. **Dry runs** of a trigger change on each unit. Read the preview with Brian.
3. **One field per unit**, with Brian's go:
- the trigger (UM20147 0.5 → 0.3; BE9441 0.04 → 0.05);
- read back; Brian checks the unit's menu;
- change it back, with another go.
4. **A notes change** on each (go).
5. **A several-field "backup unit" change** on each (go).
6. **Refusals:**
- a dry run while monitoring (expect the refusal);
- UM20147 with a schedule naming another setup, if Brian sets one up in THOR (expect the block).
7. **Alarm level (Series 3):**
- one write with Brian's go, read back and checked on BE9441's menu;
- only then flip `S3_ALARM_WRITE_MEASURED`, in its own commit naming the bench result.
Record everything in the spec's bench section and both protocol references (measured), then the devlog.
@@ -0,0 +1,403 @@
# Phase 5: changing a unit's settings by serial (design)
**Date:** 2026-11-03. **Status:** approved by Brian 2026-11-03; built 2026-11-03
(plan `docs/superpowers/plans/2026-11-03-sfm-phase5-settings.md`); **benched 2026-11-04** on both
series (results at the end). Phase 5 of
`docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md` (row 10, "change
recording settings"; build phase 5, "setup push: one field first, then several").
**Branch:** `feat/series4-sfm-parity`.
## Intent (Brian, 2026-11-03)
Change **any** of a unit's settings from SFM, and make it as easy and reliable as
possible. The goal is to fix what makes Blastware finicky. Three real cases:
- **One wrong number on a deployed unit.** UM6047 was out monitoring with its
geophone trigger at 0.03 instead of 0.300. Brian remoted into the THOR PC,
stopped it (it called in), changed the setup, made sure it was *sent*, then
restarted monitoring.
- **A typo in the notes.**
- **A backup unit.** The unit set up at the office fails in the field, so a backup
from the truck goes in with blank or stale notes and settings. There is no
computer in the field, so the office re-does the whole setup remotely, by hand,
while the person in the field stands by to press Start or power-cycle if the
link breaks.
What is wrong with THOR, as Brian and his dad experience it:
- The same screen edits a setup on disk and views a unit's setup.
- Setups get saved under random number strings.
- Editing a setup does not change the unit; you verify separately that it was sent.
Saved setups as templates would be acceptable. Not knowing whether you are
changing the unit or a file is not.
## Goals, non-goals, anti-goals
**Goals**
- Edit the unit's **live** settings, both series.
- Show exactly what will change, **old → new**, before anything is sent.
- After sending, **re-read the unit** and show what it now holds.
- Make every refusal say why, in plain words.
**Non-goals (this phase)**
- Templates, saved setups, copying from another unit.
- Restarting monitoring. **Brian presses Start**, as today; SFM never restarts on
its own.
- Setting the unit's clock. That is a later call-home receiver rule.
- **Writing the Micromate scheduler.** Next project, agreed 2026-11-03:
"record during work hours" as a plain, **configurable** setting on the unit's
page, both series, no schedule library and no setup files. On the Micromate,
it relies on the firmware's setup-less scheduler start (found in the firmware,
never sent; one bench session). On the MiniMate, its own timer setting
(undecoded). Brian's dad despises THOR's scheduler; Brian is willing to retire
it in SFM.
- Fields not yet decoded. "Any and all" grows as decoding grows.
**Anti-goals: things that would make it a failure even if it "works"**
- Any doubt about whether the unit changed.
- A screen where a file and a unit look alike, or a name SFM made up.
- Writing a byte SFM did not just read. Every byte SFM does not deliberately change
goes back exactly as read. The one exception is a byte that Blastware's (or
THOR's) own writes always set to a fixed value. Each such byte is named in the
codec with its evidence (so far: Series 3 `[26:28]` → `00 00`; my call, below).
- Sending to a monitoring unit.
- A retry. A write is sent once; what happened is read back.
## Measured basis
**1. Series 4 (Micromate): the `0x1A` setup content map.** Measured from 47
keypad snapshots on UM20147 and checksum-verified. `micromate/setup_block.py`
(`decode_setup`) reads it, with 69 tests on 15 fixtures.
| content | field |
|---|---|
| `[5]` | record mode |
| `[6:8]` | sample rate |
| `[8:10]` | histogram interval |
| `[12:16]` | pre-trigger, f32, negative |
| `[17]` | stop mode |
| `[18:22]` | record time, f32 |
| `[23]` | auto-stop |
| `[25]` | active sensors |
| `[29]` | trigger sources |
| `[30:34]` | distance |
| `[34:38]` | charge |
| `[39]` | report flags |
| `[40:42]` | job number |
| `[42:86]` | setup name |
| `[122+64n]` / `[144+64n]` | notes (label / value) |
| from `[1708]` | 48-byte channel blocks: sensor code `+4:8`, trigger `+30` (geo in/s, mic psi) |
The CRC-16/AUG-CCITT over `[0:2088]` is stored at `[2090:2092]`; THOR's write
omits it and the unit recomputes it.
- **The push sequence (from THOR's captures)** is `0xDA` (name) → `0x68`/`0x73`
(`0x08` preferences) → `0x82`/`0x83` (`0x2E` trigger) → `0x71`/`0x72` (`0x1A`
setup). `micromate.writes.plan_setup_push` reproduces THOR's frames (phase 2).
- **Not yet mapped on Series 4:** alarm level, geophone range, GPS, aux I/O, SLM
options.
**2. Series 3 (MiniMate) uses the same layout. Measured 2026-11-03.** The
compliance image as Blastware writes it is logical (unescaped), 2,092 bytes, with
`N = 2090` at `[0:2]` and the channel block "Tran" at `[1708]`.
`micromate.setup_block.decode_setup` reads it correctly:
- **BE9441's 10-26 write** (`tests/fixtures/minimate-bench-10-26-26-histogram`,
two whole sends): name, mode, 4096 sps, interval, record time 20 s, trigger
0.04 in/s, mic linear, job number and the notes all decode. Only the CRC fails
(Series 3's tail goes out stale).
- **BE11529's nine 2026-04-20 Blastware writes** (`bridges/captures/4-20-26/`,
every one with a whole image) each changed exactly the expected bytes:
| Blastware changed | bytes that moved |
|---|---|
| histogram interval (×4) | `[8:10]` |
| recording mode (×3) | `[5]` |
| geophone range | `1737` / `1785` / `1833`, the range byte at each geophone channel label `+29` |
- **The live `SUB 1A` read starts the same block.** Measured on the first data
frame of each of the four recorded reads (`_settings_replies` in
`tests/test_s3_compliance_anchor_fields.py`): unescaped, each carries `N = 2090`
12 bytes before the old "anchor", and content `[5]` reads 1 / 4 / 3 / 3. That
anchor (`be 80 00 00 00 00`) is content `[12:18]`, pre-trigger −0.25 plus stop
mode Fixed. So Series 3 can be read by content offset rather than by anchor
search, which survives an Auto-stop unit (the open question of 2026-10-17).
- **A whole `1A` read assembles to exactly the 2,090 content bytes** (measured
2026-11-03 on BE9441's 10-26 recording, 12 reads). Unescape each data frame and
take `data[11:]`. Every frame but the last then starts with one `00` byte that is
not content; drop it. This holds for Blastware's read (four 512-byte frames plus
42) and SFM's (two 1024-byte frames plus 42).
- **The round trip is exact.** Blastware re-read the block after each of its two
writes, and each re-read equals the image it had just written, all 2,090 bytes.
- **While monitoring**, the read returns `0e 'BE9441' …` (the device-info block),
as the 10-29 finding says. The unit was monitoring for 5 of the 12 reads.
- **Bytes `[26:28]`: Blastware always writes `00 00`** (all 11 writes), though the
unit reads `01 7f` after a monitoring session (BE9441 10-26, BE11529 4-20 15:19).
The unit sets them again by itself. Meaning unknown.
- **The two bytes after the block are Blastware's own.** Blastware sends a per-unit
constant: `7c ea` on all nine of BE11529's writes, `0c e9` on both of BE9441's.
It is not the block's CRC-16/AUG, and no reply in BE9441's three-hour session
contains it. SFM's `write_image` sends `00 00` there. Since a read never returns
those bytes, the read-back cannot show what the unit did with them.
- **The mode byte is shared, but its codes are not.** Series 3: `00` Single Shot,
`01` Continuous, `03` Histogram, `04` Histogram + Continuous. Series 4: `01`
Waveform, `02` Manual, `03` Histogram, `04` Combo.
- **Rules from the checker's file-side work** (seismo-relay-b6, 2026-11-03; it
measured the same content offsets on 70,042 event files and found nothing that
contradicts one shared map):
- A bitmask byte is patched **bit by bit, never rebuilt**. The trigger-sources
byte `[29]` showed an unidentified `0x80` bit on one unit.
- On Series 3, stop mode (`0` Fixed) and mic type (`2` linear) are proven for
one value each. They are not offered for writing.
- An event file's `[12:16]` is that event's captured pre-trigger, not the
setting. SFM writes only from a live read, so this matters only to anyone
tempted to build a write from a file.
- **Series-3-only fields** (measured on Series 3, not Series 4): the geophone range
byte at channel `+29`; the alarm level at channel `+38` (checker-measured on
event files; live raw `+42`).
**3. Series 3 write frames are measured (#46).** Writes use uniform escaping with
a length field. The compliance image goes in 512-byte addressed chunks. `0x68` is
written as read plus `02 00`, `0x82` plus `00 00`. The sequence is
`68→73 | 71×n→72 | 82→83 | 69→74→72`. `push_config_raw` refuses any block that
is not whole. `tests/test_minimate_write_frames.py` rebuilds Blastware's frames
byte for byte.
**4. Monitoring.**
- **Series 3:** while monitoring, the unit answers `1A` (and `0x2C`) with its
device-info block (measured 10-29 and 11-03).
- **Series 4:** it refuses call-home setup while monitoring ("Feature disabled
while monitoring", measured 11-03).
- **A stop with call-home on makes the unit call in** (measured 10-25, 10-29,
11-03).
**5. Series 4 specifics.**
- `0x1A` reads the keypad's edit buffer live: unsaved keypad edits show in the
read, and a push would commit them.
- Loading a `.MMB` replaces the active config byte for byte. The push writes
under the active setup's name (`0xDA`).
## The flow
1. **Read.** `GET /device/settings?serial=…` (it exists) returns the unit's
settings. The page shows them on the Config tab under **"On the unit BE9441 —
read 14:03"**, never anything that looks like a file.
2. **Edit and preview.** The operator changes fields, then **Preview**: a dry run.
SFM re-reads the unit's blocks on the same line, builds the new blocks, and
returns one row per field: **old → new**, plus any warnings. Nothing is sent.
3. **Send.** The same request, live, is an audited change:
- identity check, audit row, one send, never retried, read back;
- **refused with "stop monitoring first"** if the unit is monitoring, noting
that the stop makes it call in when call-home is on;
- **refused** if the unit's settings changed since the preview. The preview
carries a revision (a hash of the blocks read), and the live call must
match it.
4. **Verify.** Re-read the blocks. Every changed field must read its new value.
Every other decoded field, and every byte SFM did not deliberately change, must
read as before. The page shows **"the unit now holds"**: field, old, new, now.
Known unit-maintained bytes (the Series-4 CRC) are compared as the unit's own
checksum (`crc_ok`), not byte for byte.
5. **Start** stays the operator's button.
## Fields in the first version (Brian approved the list)
| field | Series 3 | Series 4 |
|---|---|---|
| geophone trigger level | yes (channel `+30`) | yes (channel `+30`) |
| alarm level | yes (channel `+38`; measure live) | not mapped, so not offered |
| notes: the four note slots, by the unit's own labels | yes (`Project:`, `Client:`, `User Name:`, `Seis. Loc:` on BE9441) | yes (`Location`, `Client`, `Company`, `General Notes`) |
| recording mode | yes (`[5]`; values as measured on Series 3) | yes (`[5]`; Series-4 codes) |
| sample rate | yes | yes |
| record time | yes | yes |
| histogram interval | yes | yes |
| geophone range | yes (channel `+29`) | not mapped, so not offered |
| job number (+ shown on report) | yes | yes |
A field is offered only where it is measured for that series. Values are refused
unless they are among the measured choices: sample rates 1024/2048/4096,
intervals 2/5/15/60/300/900 s, and each series' measured mode codes.
- **Numbers: the units' own limits (Brian, 2026-11-03: "I want to use the actual
unit limits, not just what we have done in the past").** From Instantel's
operator manuals in `~/seismo-relay/manuals/`:
- **Geophone trigger:** 0.005–10 in/s in steps of 0.001 (MiniMate Plus manual
716U0101 Rev 15, Appendix *Series III Specifications*; Micromate manual
721U0201 Rev 06, *Geophone Trigger Level*). It is also capped at the range's
full scale (10 / 1.25 in/s). When range and trigger change in one request,
check the trigger against the **new** range.
- **Record time:**
- Micromate: 1–90 s (*Record Time*).
- MiniMate: from 1 s to the manual's §4.4 *Maximum Record Times* for a
1 MB unit, four channels, at the chosen sample rate: 104 s at 1024 sps,
52 s at 2048, 26 s at 4096. In Histogram Combo, 13 s (§3.8.9). The units
measured report about 960 KB in total memory (BE11529: 983,026 bytes), the
1 MB model.
- **Job number:** 1–9999 (both manuals).
- **The read-back is the safety net.** A unit that does not take a value (for
instance, cuts a record time to what its memory allows) shows as not taken,
with what it actually holds.
- Values seen across 75,958 Blastware reports (2016–2026) sit well inside these
limits: trigger 0.005–0.500 in/s, record time 1–10 s, job number 1.
- **Units:** refuse a level write unless the channel's unit string reads the
measured one (`in.` for a geophone). A unit set to Metric is unmeasured.
- **Notes:** edited by slot, under the label the unit itself shows (labels can be
renamed and are not identifiers). The value is at most its field width less
one byte, printable ASCII.
- Not in v1: Series 3's fifth slot, `Extended Notes` (value `\n` on BE9441).
Blastware's extended notes are unmeasured and may live elsewhere.
- Not in v1: Series 4's 16-byte field at content `[1064]` (`Loc 1` on
UM12947), undecoded.
## Architecture
- **One setup-block codec for both series.** Keep `micromate/setup_block.py` as
the field map and add `encode_setup(content, changes) -> content`: field patches
only, every other byte as given. It stays a pure codec library: no I/O, no
`sfm` imports, no import cycle with `minimateplus`. Series-specific fields (the
Series-3 range and alarm) are marked by series.
- **Series 3 read.** Assemble the `1A` read into the logical 2,090-byte block:
unescape, strip the 12-byte reply prefix and the inter-frame headers
(`read_compliance_config`). Decode it by content offset.
- **Series 3 write.** The patched logical block plus the tail becomes the
compliance image for `push_config_raw`. Event index (`0x08`), trigger (`0x2E`)
and waveform data (`0x09`) are echoed as read, in Blastware's sequence.
- On `0x09`, Blastware echoed the unit's bytes on all nine April writes
(`[200:202]` = `8c 76` read and written). Only BE9441's 10-26 writes changed
them (`17 17` read, `78 76` written, and read back so). The meaning is
unknown, so SFM echoes.
- **The raw-offset `_encode_compliance_config` is retired.**
- **The legacy write (`/device/config`, `/device/config/project`) is retired (my
call).** It retries a whole write on a TCP error, is not audited, does no
read-back, does not refuse a monitoring unit, and needs no serial: every
anti-goal at once. Its only user is the webapp's by-host Config form, and
Terra-View does not call it. Its routes answer with a pointer to the by-serial
change, and the by-host form becomes read-only.
- **Series 4 write.** `plan_setup_push(prefs, trigger, patched_setup, name)`.
- **No setup files in the operator's view (Brian, 2026-11-03).** "We treat the
Micromate setups just like Minimate setups … the unit just has its settings,
and we change it based on the job. We don't send setups to the unit." A
backup unit is usually on whatever setup its previous job left. So SFM
rewrites the setup the unit is running, in place, under its own name. It
never asks for a file or a name, and never creates one. The name may show as
a read-only detail, since the unit's screen shows it.
- **The scheduler can undo a change (Brian, 2026-11-03, with THOR's Manage
Schedules screen).** Work-hours Micromates run a THOR schedule, e.g. Start
Monitoring 07:00 with setup `Mele-PWSA-Carroll -Loc 4`, stop 18:30, repeat
daily. THOR sends the schedule with its setup, and each scheduled start loads
the setup it names. So the preview and the send read `schedule.dat` (format
decoded, reference *The schedule record format*), read-only. A start action
naming a setup other than the one being changed blocks the send: "this unit's
schedule loads <name> at 07:00, which would replace this change." When the
schedule names the active setup (the usual case after a scheduled start), the
change survives, and the preview says when the next scheduled start is.
SFM never writes the schedule in this phase.
- The name comes from the `0x41` read, unstripped.
- Refuse `factory.MMB` and any target that is not the active setup (spec). The
refusal says it plainly: "this unit is running its factory setup; load any
other setup on its keypad, then try again." Brian says the team does not use
the factory setup, so this should be rare.
- `ENABLEABLE_WRITES` gains `0xDA 0x68 0x73 0x82 0x83 0x71 0x72`.
- The keypad edit buffer: warn in the preview that a unit with someone in its
menu would have those edits committed. The check the spec names, `0x1A`
against the active `.MMB` via `0x94`/`0x48`, is a bench question first.
- **The change path.** It keeps run_change's guarantees: identity, audit, one
send, read back, `ChangeUnconfirmed` with `sent`/`audit_id`. The "state" is a
set of fields, so either `run_change` takes a verify function or a sibling core
shares its parts. The builder decides; the guarantees do not change. The audit
row keeps the per-field changes, both blocks (hex) and the verdict.
- **Routes.** `POST /device/settings/change?serial=…` (serial required) with body
`{changes: {field: value}, revision}` and `dry_run`, `caller`. The response is
per-field `old` / `new` / `now`, through `_change_response`. A dry run needs no
revision and returns one. **A live call without the revision of a preview is
refused** (my call): nothing reaches a unit unless someone saw old → new.
- **Page.** The Config tab by serial becomes the unit's edit form: Preview → Send
(confirm) → "the unit now holds". New logic goes in
`sfm/static/device_routing.js` with Node tests, and glue in
`sfm/static/sfm_webapp.js` (no inline JS).
## Verification
- **Series 3, byte for byte.** For each of the 11 Blastware compliance writes,
apply the new encoder to the read before it (or the previous image), with the
fields Blastware changed. It must reproduce Blastware's content `[0:2090]`. The
two trailing bytes are compared separately, since they are Blastware's constant.
Ten writes change one field. BE9441's 16:26 write changes five things: mode,
sample rate 2048 → 4096, interval, the mic in the sensors byte `[25]`, and
`[26:28]`. That one is tested with all of them, through the codec, though v1's
page does not offer the sensors byte.
The frames rebuild through `push_config_raw`'s path (the #46 tests).
- **Series 3, read side.** The assembly rule above, pinned as a test on the 12
reads of BE9441's 10-26 recording. Each read-back equals the write before it.
- **Series 4.** THOR's setup-push captures still reproduce, with no field changed.
Any capture where THOR changed a field becomes a byte-for-byte test.
- **Bench, with Brian's go per send, per series:**
1. A dry run of a trigger change, then send, read back, check the unit's menu,
and change it back.
2. A notes change.
3. A several-field "backup unit" change.
4. A dry run while monitoring, expecting the refusal.
## Bench 2026-11-04 (results)
Brian at BE9441 and UM20147, each on its own modem; every send with his go.
Notes: `~/bench-logs/2026-11-04-sfm-settings/`.
- **Both series change correctly.** Each change was acknowledged, read back as
sent, and confirmed on the unit's own screen; both units ended byte for byte as
found.
- BE9441: trigger each way, a note, several fields at once, the alarm, a full
restore.
- UM20147: trigger, several fields (two notes, job number and its flag, record
time), a full restore. The unit's recomputed CRC equalled SFM's.
- **Fixed at the bench (`9992b25`):** the first live MiniMate read came back one
byte long. An escaped checksum byte leaves its `0x10` behind (about 1 frame in
85; the recordings never had it). The read now takes exactly the lengths it
asked for, and so does the waveform read (`c790e20`).
- **🔑 The keypad menu wins.** A MiniMate change sent while its setup menu is
open is acknowledged and read back, then lost when the operator presses Cancel
or Save: the menu writes its copy of the whole block back. SFM cannot see this
happen; the MiniMate preview now warns. Rule for the field-plus-office routine:
nobody in the unit's menus while the office sends.
- **The MiniMate alarm write is measured**, so it is now writable (`55c7b7b`).
- **Refused while recording, both series, nothing sent.** A recording MiniMate
sometimes leaves a preview at "no answer" rather than the refusal.
- **The Micromate scheduler switch is in no block SFM reads.** UM20147 carries a
leftover THOR schedule (Fay setup, 07:00 daily) with the switch Off; SFM blocks
it, a false alarm here. The bench used a scratch-only override.
- Next: a THOR bridge recording to find the switch (parked for work hours).
- Meanwhile, worth considering: let the operator confirm "scheduler off" in the
preview.
## Calls I made (Claude), for Brian to check
- **Series 3 `[26:28]` goes out as `00 00`, as Blastware writes it**, rather than
the `01 7f` the unit may read. Measured beats inferred: Blastware's value is on
11 accepted writes, and writing back `01 7f` has never been tried.
- **The two bytes after the Series 3 block stay `00 00`**, as `write_image` sends
them (a unit accepted that in the April 2026 test). Blastware's per-unit
constant cannot be derived from anything SFM reads. The first bench write checks
that the unit takes the block, and its menu shows the change.
- **The `0x09` block is echoed as read**, as Blastware did on all nine April writes.
- **Level writes are refused unless the channel's unit string is the measured
`in.` / `in`** (a unit set to Metric is unmeasured).
- **Notes are edited by slot under the unit's own labels**, four slots on each
series. Series 3 extended notes and Series 4's separate location field wait.
- **The legacy by-host write is retired**; the by-host form becomes read-only.
- **A live send needs a preview's revision.**
- **Preview re-reads the unit** rather than trusting the page's copy, and Send
refuses if the unit changed since the preview.
- **The edit form lives on the Config tab, by serial**, replacing the legacy
read-modify-write form for units reached by serial.
## Left to the builder
- The module layout for the shared codec, within the no-cycle, pure-codec rule.
- `run_change` generalised versus a sibling core.
- The exact revision hash.
- Page layout details.
-107
View File
@@ -60,7 +60,6 @@ from minimateplus.framing import build_bw_frame, SESSION_RESET
from minimateplus.client import (
MiniMateClient,
_decode_compliance_config_into,
_encode_compliance_config,
)
from minimateplus.models import DeviceInfo
@@ -462,111 +461,6 @@ def exp_fewer_polls(host: str, port: int) -> tuple[str, str, dict]:
t.disconnect()
# ══════════════════════════════════════════════════════════════════════════════
# EXP6 — Compliance-only write (71×3→72), skip event index + trigger + waveform
# ══════════════════════════════════════════════════════════════════════════════
#
# Blastware's full write sequence: 68→73 | 71×3→72 | 82→83 | 69→74→72
# We want to know: can we write ONLY the compliance block (71×3→72)?
#
# Test procedure:
# 1. Read current compliance config (SUB 1A)
# 2. Patch the "notes" field to a test marker
# 3. Write ONLY 71×3→72 (skip 68, 73, 82, 83, 69, 74, final 72)
# 4. Read back (SUB 1A) and verify the change was written
# 5. Restore original value
#
# If PASS: we can push individual config fields without touching event index,
# trigger config, or waveform data — huge simplification.
# If FAIL: the device needs the full write sequence (may reject partial write).
#
# SAFETY: We restore original data in a finally block. If the restore write
# fails, the device will have the test marker in "notes" — harmless but visible.
_EXP6_MARKER = "[exp6-test]"
def exp_compliance_only(host: str, port: int) -> tuple[str, str, dict]:
"""Write compliance block alone (71×3→72), verify, and restore."""
client, info = connect_client(host, port)
original_raw: Optional[bytes] = None
try:
proto = client._proto
if proto is None:
return "FAIL", "Could not get protocol handle from client", {}
# 1. Read current compliance
print(" Reading current compliance config (SUB 1A)…")
original_raw = proto.read_compliance_config()
print(f" Got {len(original_raw)} bytes of compliance config")
# Find current notes value for display
info_obj = DeviceInfo()
_decode_compliance_config_into(original_raw, info_obj)
cc = info_obj.compliance_config
orig_notes = cc.notes if cc else "(unknown)"
print(f" Current notes field: {orig_notes!r}")
# 2. Build modified payload with test marker in notes
test_notes = _EXP6_MARKER
modified_raw = _encode_compliance_config(
original_raw,
notes=test_notes,
)
print(f" Encoded modified compliance payload ({len(modified_raw)} bytes)")
print(f" Patching notes: {orig_notes!r} → {test_notes!r}")
# 3. Write ONLY the compliance block: 71×3 → 72
print(" Writing compliance ONLY (71×3→72) — skipping 68/73/82/83/69/74…")
proto.write_compliance_config_raw(modified_raw)
print(" Write complete — device acked 71×3→72")
# 4. Read back and verify
print(" Reading back compliance config to verify…")
readback_raw = proto.read_compliance_config()
readback_info = DeviceInfo()
_decode_compliance_config_into(readback_raw, readback_info)
rb_cc = readback_info.compliance_config
readback_notes = rb_cc.notes if rb_cc else "(decode failed)"
print(f" Read-back notes: {readback_notes!r}")
write_worked = (readback_notes == test_notes)
print(f" Write verified: {write_worked}")
details = {
"original_notes": orig_notes,
"written_notes": test_notes,
"readback_notes": readback_notes,
"write_verified": write_worked,
}
if write_worked:
return "PASS", "Compliance-only write works! No event index or trigger writes needed.", details
else:
return "FAIL", f"Write was not reflected in read-back (got {readback_notes!r})", details
except ProtocolError as exc:
return "FAIL", f"Protocol error: {exc}", {}
finally:
# Restore original compliance data regardless of outcome
if original_raw is not None:
print(" Restoring original compliance config…")
try:
proto2 = client._proto
if proto2:
proto2.write_compliance_config_raw(
_encode_compliance_config(original_raw) # no-op patch = verbatim
)
print(" Restore complete")
else:
print(" WARNING: protocol handle gone — could not restore")
except Exception as exc_r:
print(f" WARNING: restore failed: {exc_r}")
client.close()
# ══════════════════════════════════════════════════════════════════════════════
# Registry + main
# ══════════════════════════════════════════════════════════════════════════════
EXPERIMENTS = {
@@ -575,7 +469,6 @@ EXPERIMENTS = {
"no_5a": ("EXP3", exp_no_5a, "Event record (0C) without bulk waveform (5A)"),
"skip_1e": ("EXP4", exp_skip_1e, "0A/0C with cached key — skip initial 1E"),
"fewer_polls": ("EXP5", exp_fewer_polls, "1 POLL before 5A instead of Blastware's 3"),
"compliance_only": ("EXP6", exp_compliance_only, "Compliance-only write (71×3→72), no other blocks"),
}
+23
View File
@@ -48,6 +48,7 @@ from .models import (
MicromateState,
)
from .protocol import MicromateProtocol, ProtocolError
from .schedule import SCHEDULE_PATH
from .setup_block import decode_setup
log = logging.getLogger(__name__)
@@ -333,6 +334,28 @@ class MicromateClient:
"""`SUB 0x41` — the loaded `.MMB` file name, e.g. `TEST1.mmb`."""
return _cstring(_content(self._proto.read_active_setup_name()))
def get_active_setup_raw(self) -> str:
"""The `0x41` name exactly as stored, up to its NUL -- NOT stripped, so a
setup push writes back the very name the unit holds."""
return _content(self._proto.read_active_setup_name()).split(b"\x00")[0].decode("ascii", "replace")
def get_prefs_content(self) -> bytes:
"""`SUB 0x08` -- the preferences block's content (a setup push sends it back)."""
return _content(self._proto.read_event_index())
def get_trigger_content(self) -> bytes:
"""`SUB 0x2E` -- the trigger block's content (a setup push sends it back)."""
return _content(self._proto.read_trigger_config())
def get_setup_content(self) -> bytes:
"""`SUB 0x1A` -- the setup block's content, undecoded (2,092 B, CRC last).
⚠ The keypad's edit buffer: unsaved menu edits come back too."""
return _content(self._proto.read_compliance_config())
def read_schedule(self) -> bytes:
"""`schedule.dat`, read-only (`micromate.schedule.parse_schedule` reads it)."""
return self._proto.read_file(SCHEDULE_PATH)
def get_setup(self, *, verify: bool = True) -> MicromateSetup:
"""`SUB 0x1A` — what the unit is set to, decoded. One read.
+4 -1
View File
@@ -86,7 +86,10 @@ READ_SUBS: Mapping[int, str] = MappingProxyType(_READ_SUBS)
# (0xA8/0xAA), raw file writes (0x8D/0x8E -- they could reach the modem
# settings) and 0xA2 never belong here without one. Phase 4 (2026-11-02) added
# the call-home write and its confirm (spec row 9: enable/disable only).
ENABLEABLE_WRITES = frozenset({0x96, 0x97, 0x7E, 0x7F})
# Phase 5 (2026-11-03) added the setup push -- name, preferences, trigger and setup
# blocks with their confirms -- for changing a unit's settings by serial (spec row 10).
ENABLEABLE_WRITES = frozenset({0x96, 0x97, 0x7E, 0x7F,
0xDA, 0x68, 0x73, 0x82, 0x83, 0x71, 0x72}) # + the setup push (phase 5)
class OpcodeRefused(RuntimeError):
+31
View File
@@ -93,6 +93,8 @@ SUB_STATE = 0x49
SUB_BULK_DOWNLOAD = 0x5A
SUB_POLL = 0x5B
SUB_ARM_EVENT = 0x93
SUB_FILE_READ_NEXT = 0x48 # file transfer: next page of the file opened by 0x94
SUB_FILE_OPEN_READ = 0x94 # file transfer: open a file by path, for reading
# ⚠ Reads are SINGLE-STEP. Series III probes at offset 0 to learn the length,
# then reads again at that length; a Micromate returns the whole block when
@@ -102,6 +104,10 @@ READ_ALL = 0xFFFF
# The two commands that do NOT use READ_ALL, and the data length each returned
# on UM12947 (firmware 11.0CB).
_FILE_OPEN_PARAMS = bytes([0, 0, 0, 1, 0, 0, 0, 0, 0, 0])
_FILE_FIRST_PAGE_PARAMS = bytes([0, 0, 0, 0, 0, 0, 0, 1, 0, 0])
_MAX_FILE_PAGES = 64
_OFFSETS = {
SUB_POLL: 0x0030, # 59 B — the one offset THOR treats as a constant
SUB_SERIAL: 0x000A, # 21 B
@@ -376,6 +382,31 @@ class MicromateProtocol:
"""
return self._read(SUB_SETUP_NEXT)
# ── Files, by path (read-only) ────────────────────────────────────────────
def read_file(self, path: str) -> bytes:
"""A file off the unit, by full path: `0x94` + the path opens it, then
`0x48` pages follow until an all-zero reply. The first `0x48` reply is a
descriptor, not file content. Frames are THOR's exactly (UM12947 reading
`schedule.dat`, 2026-09-24): `0x94` carries `params[3] = 1` and the path,
unpadded, as data with offset = its length; the first `0x48` carries
`params[7] = 1`, the rest none. Returns the content (each page's data
after its 11-byte prefix), joined.
"""
raw = path.encode("ascii")
self._request(build_request(SUB_FILE_OPEN_READ, len(raw), _FILE_OPEN_PARAMS, raw),
0xFF - SUB_FILE_OPEN_READ)
body = bytearray()
for page in range(_MAX_FILE_PAGES):
f = self._exchange(SUB_FILE_READ_NEXT,
params=_FILE_FIRST_PAGE_PARAMS if page == 0 else bytes(10))
if page == 0:
continue # the descriptor
if not any(f.data):
return bytes(body)
body += f.data[11:]
raise ProtocolError(f"{path}: no end of file after {_MAX_FILE_PAGES} pages")
# ── Event chain ───────────────────────────────────────────────────────────
def arm_event(self) -> MicromateFrame:
+75
View File
@@ -0,0 +1,75 @@
"""schedule.py -- a Micromate's schedule file, parsed. Pure; read-only by design.
THOR's scheduler lives in a file on the unit, `\\system\\schedule\\schedule.dat`,
read by path (`MicromateProtocol.read_file`). The format is decoded in
docs/micromate_protocol_reference.md, *The schedule record format* (measured on
UM12947, 2026-09-24/25): 260-byte records,
[0] record 0 only: 3 = repeat on, 2 = repeat off
[4] half-hour slot, 0-47
[5] day (3 in every record seen -- undetermined)
[6] action bitmask: 2 start monitoring with setup, 4 stop, 8 self-check,
16 auto call home
[7] setup-name length
[8:260] setup name (empty for actions that take none)
Why SFM reads it (phase 5): each scheduled start LOADS the setup it names. A
settings change to any other setup would be replaced at the next start, so SFM
refuses that change -- `schedule_conflicts`. SFM never writes the schedule.
"""
from __future__ import annotations
from dataclasses import dataclass
from typing import List, Tuple
SCHEDULE_PATH = "\\system\\schedule\\schedule.dat"
_RECORD = 260
_NAME_MAX = _RECORD - 8
_ACTIONS = ((0x02, "start_with_setup"), (0x04, "stop"), (0x08, "self_check"), (0x10, "call_home"))
_KNOWN_BITS = sum(bit for bit, _ in _ACTIONS)
@dataclass(frozen=True)
class ScheduleEntry:
index: int
time: str # "HH:MM", from the half-hour slot
day: int # the raw byte; undetermined
action_bits: int
actions: Tuple[str, ...] # named bits; any other set bit as "unknown(0xNN)"
setup: str # "" when the action takes no setup
def _actions(bits: int) -> Tuple[str, ...]:
named = tuple(name for bit, name in _ACTIONS if bits & bit)
unknown = tuple(f"unknown(0x{1 << i:02x})" for i in range(8)
if bits & (1 << i) and not (1 << i) & _KNOWN_BITS)
return named + unknown
def parse_schedule(body: bytes) -> List[ScheduleEntry]:
"""The entries in a schedule file body. A record with nothing in [4:8] and
no name ends the list (the file is padded with zeros)."""
out: List[ScheduleEntry] = []
for i in range(len(body) // _RECORD):
r = body[i * _RECORD:(i + 1) * _RECORD]
n = min(r[7], _NAME_MAX)
name = r[8:8 + n].decode("ascii", "replace") if n else ""
if not any(r[4:8]) and not name:
break
slot = r[4]
out.append(ScheduleEntry(index=i, time=f"{slot // 2:02d}:{(slot % 2) * 30:02d}", day=r[5],
action_bits=r[6], actions=_actions(r[6]), setup=name))
return out
def _same_setup(a: str, b: str) -> bool:
return a.strip().casefold() == b.strip().casefold()
def schedule_conflicts(entries: List[ScheduleEntry], active_setup: str) -> List[ScheduleEntry]:
"""The scheduled starts that would load a setup other than `active_setup`
(compared ignoring case and surrounding spaces: THOR and the keypad disagree
on case, e.g. `factory.MMB` / `test2.mmb`)."""
return [e for e in entries
if "start_with_setup" in e.actions and e.setup and not _same_setup(e.setup, active_setup)]
+14
View File
@@ -88,6 +88,20 @@ def crc_ok(content: bytes) -> bool:
return _crc16_aug_ccitt(content[: n - 2]) == int.from_bytes(content[n : n + 2], "big")
def with_crc(content: bytes) -> bytes:
"""`content` with its trailing checksum recomputed: CRC-16/AUG-CCITT over
``[0:N-2]``, stored big-endian at ``[N:N+2]`` (the rule `crc_ok` checks).
THOR's write omits the checksum and the unit computes its own; this keeps a
patched block self-consistent so a plan's integrity check still means
something."""
n = int.from_bytes(content[0:2], "big")
if n < 2 or len(content) < n + 2:
raise ValueError(f"block header says {n} but the block is {len(content)} B")
out = bytearray(content)
out[n : n + 2] = _crc16_aug_ccitt(content[: n - 2]).to_bytes(2, "big")
return bytes(out)
def _f32(c: bytes, offset: int) -> float:
return struct.unpack_from(">f", c, offset)[0]
+439
View File
@@ -0,0 +1,439 @@
"""setup_fields.py -- the settings an operator can change, for both series (phase 5).
Pure byte interpretation: no I/O, no device, no `sfm` and no `minimateplus`
imports. Every offset is into the settings block's CONTENT:
* Series 4: the `0x1A` content, 2,092 bytes (N = 2090, then its CRC).
* Series 3: the 1A read assembled by `minimateplus.protocol.
assemble_compliance_content`, 2,090 bytes (N = 2090, no CRC in the read).
**One layout.** Measured 2026-11-03: Blastware's MiniMate compliance image IS
Series IV's `0x1A` content layout (`decode_setup` reads it), and each of
BE11529's nine 2026-04-20 Blastware writes moved exactly the bytes of the field
it changed. Series 4's offsets are from the 47-snapshot keypad pass on UM20147
(2026-10-17/19). Fields measured on one series only are offered on that series
only.
**Limits are the units' own, from Instantel's manuals** (Brian, 2026-11-03: "I
want to use the actual unit limits, not just what we have done in the past"):
* geophone trigger 0.005-10 in/s in steps of 0.001 -- MiniMate Plus manual
716U0101 Rev 15, Appendix *Series III Specifications*; Micromate manual
721U0201 Rev 06, *Geophone Trigger Level* -- and at most the range's full
scale;
* record time: Micromate 1-90 s (*Record Time*); MiniMate up to §4.4's
*Maximum Record Times* for a 1 MB unit, channels 1-4, at the sample rate,
and 13 s in Histogram Combo (§3.8.9);
* job number 1-9999 (both manuals).
What a unit does not take, the read-back shows (`settings_state`).
tests/test_setup_fields.py holds this to Blastware's writes and the keypad
fixtures byte for byte.
"""
from __future__ import annotations
import hashlib
import math
import struct
from typing import Any, Dict, List, Optional, Set
from .setup_block import crc_ok, with_crc
class SettingsValueError(ValueError):
"""A requested change SFM will not make, said plainly. Nothing is sent."""
# ── Layout ──────────────────────────────────────────────────────────────────
_MODE = 5
_SAMPLE_RATE = slice(6, 8) # u16 BE
_HIST_INTERVAL = slice(8, 10) # u16 BE seconds
_RECORD_TIME = 18 # f32 BE seconds
_REPORT_FLAGS = 39 # bit 0x02 = job number on the report (measured both series)
_JOB_SHOWN = 0x02
_JOB_NUMBER = slice(40, 42) # u16 BE
_NOTE_LABEL, _NOTE_VALUE, _NOTE_STRIDE, _NOTES = 122, 144, 64, 4
_NOTE_LABEL_WIDTH, _NOTE_WIDTH = 22, 42
NOTE_MAX = _NOTE_WIDTH - 1 # a NUL always ends the value
_CHANNELS, _CHANNEL_SIZE, _GEOPHONES = 1708, 48, (0, 1, 2)
_CH_RANGE = 29 # u8: 0 Normal (10 in/s), 1 Sensitive (1.25 in/s) -- Series 3, measured
_CH_TRIGGER = 30 # f32 BE, in/s for a geophone
_CH_UNIT = slice(34, 38) # "in." / "in" (the keypad re-renders it); NOT an identifier
_CH_ALARM = 38 # f32 BE -- Series 3; write measured at the bench 2026-11-04
_FULL_SCALE = {0: 10.0, 1: 1.25}
_RANGES = {"normal": 0, "sensitive": 1}
# Blastware writes these bytes as a fixed value on every write on record (11 of 11,
# both units); the unit reads `01 7f` there after a monitoring session. Meaning
# unknown -- SFM writes what Blastware writes. Series 3 only.
S3_BLASTWARE_FIXED = {26: b"\x00\x00"}
# Measured at the bench 2026-11-04 (BE9441, Brian's go): 1.0 -> 1.5 -> 1.0 in/s,
# each acknowledged, read back, and shown in the unit's own setup menu; the write
# moved exactly channel +39 of the three geophones (the f32 at +38).
S3_ALARM_WRITE_MEASURED = True
MODES = {
3: {"single_shot": 0x00, "continuous": 0x01, "histogram": 0x03, "histogram_continuous": 0x04},
4: {"waveform": 0x01, "manual": 0x02, "histogram": 0x03, "combo": 0x04},
}
_MODE_LABELS = {
"single_shot": "Single Shot", "continuous": "Continuous", "histogram": "Histogram",
"histogram_continuous": "Histogram + Continuous", "waveform": "Waveform", "manual": "Manual",
"combo": "Combo",
}
SAMPLE_RATES = (1024, 2048, 4096)
INTERVALS = (2, 5, 15, 60, 300, 900)
TRIGGER_MIN, TRIGGER_MAX, TRIGGER_STEP = 0.005, 10.0, 0.001
RECORD_MIN_S = 1.0
S4_MAX_RECORD_S = 90.0
S3_MAX_RECORD_S = {1024: 104.0, 2048: 52.0, 4096: 26.0}
S3_COMBO_MAX_RECORD_S = 13.0
JOB_MIN, JOB_MAX = 1, 9999
_SERIES_FIELDS = {
3: ("record_mode", "sample_rate", "histogram_interval_s", "record_time_s", "geo_trigger_ips",
"geo_range", "geo_alarm_ips", "job_number", "job_number_shown",
"note_1", "note_2", "note_3", "note_4"),
4: ("record_mode", "sample_rate", "histogram_interval_s", "record_time_s", "geo_trigger_ips",
"job_number", "job_number_shown", "note_1", "note_2", "note_3", "note_4"),
}
_LEVELS = ("geo_trigger_ips", "geo_alarm_ips")
def _ch(k: int) -> int:
return _CHANNELS + _CHANNEL_SIZE * k
def _f32(c: bytes, offset: int) -> float:
return struct.unpack_from(">f", c, offset)[0]
def _shown(v: float) -> float:
"""An f32 as an operator typed it: 0.30000001192 is 0.3."""
return round(v, 6)
def _note_offsets(n: int) -> tuple:
label = _NOTE_LABEL + n * _NOTE_STRIDE
value = _NOTE_VALUE + n * _NOTE_STRIDE
return label, value
def _note_label(c: bytes, n: int) -> str:
start, _ = _note_offsets(n)
raw = c[start:start + _NOTE_LABEL_WIDTH].split(b"\x00")[0]
text = raw.decode("ascii", "replace").strip().rstrip(":").strip()
return text or f"Note {n + 1}"
def _note_value(c: bytes, n: int) -> str:
_, start = _note_offsets(n)
return c[start:start + _NOTE_WIDTH].split(b"\x00")[0].decode("ascii", "replace")
def field_bytes(series: int) -> Dict[str, Set[int]]:
"""Every byte each field may move, by content offset."""
def chans(rel: int, width: int) -> Set[int]:
return {_ch(k) + rel + i for k in _GEOPHONES for i in range(width)}
out = {
"record_mode": {_MODE},
"sample_rate": set(range(6, 8)),
"histogram_interval_s": set(range(8, 10)),
"record_time_s": set(range(_RECORD_TIME, _RECORD_TIME + 4)),
"geo_trigger_ips": chans(_CH_TRIGGER, 4),
"geo_range": chans(_CH_RANGE, 1),
"geo_alarm_ips": chans(_CH_ALARM, 4),
"job_number": set(range(40, 42)),
"job_number_shown": {_REPORT_FLAGS},
}
for n in range(_NOTES):
_, v = _note_offsets(n)
out[f"note_{n + 1}"] = set(range(v, v + _NOTE_WIDTH))
return {f: out[f] for f in _SERIES_FIELDS[series]}
# ── Reading ─────────────────────────────────────────────────────────────────
def _mode_name(c: bytes, series: int) -> str:
code = c[_MODE]
for name, value in MODES[series].items():
if value == code:
return name
return f"unknown(0x{code:02x})"
def _range_code(c: bytes) -> int:
return c[_ch(0) + _CH_RANGE]
def _full_scale(c: bytes, series: int, range_name: Optional[str] = None) -> Optional[float]:
if series == 4:
return _FULL_SCALE[0] # Series 4's range byte is not mapped; 10 in/s is the hardware's
code = _RANGES[range_name] if range_name is not None else _range_code(c)
return _FULL_SCALE.get(code)
def _s3_max_record(rate: int, mode: str) -> Optional[float]:
top = S3_MAX_RECORD_S.get(rate)
if top is None:
return None
return min(top, S3_COMBO_MAX_RECORD_S) if mode == "histogram_continuous" else top
def _unit_string(c: bytes) -> List[str]:
return [c[_ch(k) + _CH_UNIT.start:_ch(k) + _CH_UNIT.stop].replace(b"\x00", b"")
.replace(b".", b"").decode("ascii", "replace") for k in _GEOPHONES]
def editable_fields(content: bytes, series: int) -> List[Dict[str, Any]]:
"""The fields an operator can change, described for a form: field, label,
kind ("number" / "choice" / "text" / "bool"), value, and as relevant unit,
min, max, step, choices [{value, label}], maxlength, readonly."""
c = content
rate = int.from_bytes(c[_SAMPLE_RATE], "big")
mode = _mode_name(c, series)
out: List[Dict[str, Any]] = [
{"field": "record_mode", "label": "Record mode", "kind": "choice", "value": mode,
"choices": [{"value": n, "label": _MODE_LABELS[n]} for n in MODES[series]]},
{"field": "sample_rate", "label": "Sample rate", "kind": "choice", "value": rate, "unit": "sps",
"choices": [{"value": r, "label": f"{r} sps"} for r in SAMPLE_RATES]},
{"field": "histogram_interval_s", "label": "Histogram interval", "kind": "choice",
"value": int.from_bytes(c[_HIST_INTERVAL], "big"),
"choices": [{"value": s, "label": f"{s} s" if s < 60 else f"{s // 60} min"} for s in INTERVALS]},
{"field": "record_time_s", "label": "Record time", "kind": "number", "unit": "s",
"value": _shown(_f32(c, _RECORD_TIME)), "min": RECORD_MIN_S,
"max": S4_MAX_RECORD_S if series == 4 else _s3_max_record(rate, mode)},
{"field": "geo_trigger_ips", "label": "Geophone trigger", "kind": "number", "unit": "in/s",
"value": _shown(_f32(c, _ch(0) + _CH_TRIGGER)), "min": TRIGGER_MIN,
"max": min(TRIGGER_MAX, _full_scale(c, series) or TRIGGER_MAX), "step": TRIGGER_STEP},
]
if series == 3:
code = _range_code(c)
name = next((n for n, v in _RANGES.items() if v == code), f"unknown(0x{code:02x})")
out.append({"field": "geo_range", "label": "Geophone range", "kind": "choice", "value": name,
"choices": [{"value": "normal", "label": "Normal (10 in/s)"},
{"value": "sensitive", "label": "Sensitive (1.25 in/s)"}]})
out.append({"field": "geo_alarm_ips", "label": "Geophone alarm", "kind": "number",
"unit": "in/s", "value": _shown(_f32(c, _ch(0) + _CH_ALARM)),
"min": TRIGGER_MIN, "max": _full_scale(c, 3) or TRIGGER_MAX,
"step": TRIGGER_STEP, "readonly": not S3_ALARM_WRITE_MEASURED})
out.append({"field": "job_number", "label": "Job number", "kind": "number",
"value": int.from_bytes(c[_JOB_NUMBER], "big"), "min": JOB_MIN, "max": JOB_MAX, "step": 1})
out.append({"field": "job_number_shown", "label": "Job number on report", "kind": "bool",
"value": bool(c[_REPORT_FLAGS] & _JOB_SHOWN)})
for n in range(_NOTES):
out.append({"field": f"note_{n + 1}", "label": _note_label(c, n), "kind": "text",
"value": _note_value(c, n), "maxlength": NOTE_MAX})
return out
def field_values(content: bytes, series: int) -> Dict[str, Any]:
return {d["field"]: d["value"] for d in editable_fields(content, series)}
def field_rows(before: bytes, written: bytes, series: int, fields, now: Optional[bytes] = None) -> Dict[str, Dict[str, Any]]:
"""For each changed field: its label, the value the unit had (old), the value
sent (new) and, given a read-back, what the unit now holds (now)."""
a, w = field_values(before, series), field_values(written, series)
n = field_values(now, series) if now is not None else None
labels = {d["field"]: d["label"] for d in editable_fields(written, series)}
out: Dict[str, Dict[str, Any]] = {}
for f in fields:
row: Dict[str, Any] = {"label": labels[f], "old": a[f], "new": w[f]}
if n is not None:
row["now"] = n[f]
out[f] = row
return out
# ── Checking ────────────────────────────────────────────────────────────────
def _number(field: str, v: Any) -> float:
if isinstance(v, bool) or not isinstance(v, (int, float)) or not math.isfinite(v):
raise SettingsValueError(f"{field} must be a number, not {v!r}")
return float(v)
def _integer(field: str, v: Any) -> int:
if isinstance(v, bool) or not isinstance(v, int):
raise SettingsValueError(f"{field} must be a whole number, not {v!r}")
return v
def check_changes(content: bytes, series: int, changes: Dict[str, Any]) -> Dict[str, Any]:
"""The changes, normalised -- or SettingsValueError naming the first one SFM
will not make, and why. Checks names, types and the units' own limits, then
what depends on this unit's block: its unit strings and its range."""
if series not in _SERIES_FIELDS:
raise SettingsValueError(f"Series {series} has no settings SFM can change")
if not isinstance(changes, dict) or not changes:
raise SettingsValueError("no settings to change")
allowed = _SERIES_FIELDS[series]
out: Dict[str, Any] = {}
for field, v in changes.items():
if field not in allowed:
raise SettingsValueError(f"{field} is not a setting SFM can change on a Series {series} unit")
if field == "record_mode":
if v not in MODES[series]:
raise SettingsValueError(f"record_mode must be one of {', '.join(MODES[series])}, not {v!r}")
out[field] = v
elif field == "sample_rate":
if _integer(field, v) not in SAMPLE_RATES:
raise SettingsValueError(f"sample_rate must be one of {SAMPLE_RATES}, not {v}")
out[field] = v
elif field == "histogram_interval_s":
if _integer(field, v) not in INTERVALS:
raise SettingsValueError(f"histogram_interval_s must be one of {INTERVALS} s, not {v}")
out[field] = v
elif field == "geo_range":
if v not in _RANGES:
raise SettingsValueError(f"geo_range must be normal or sensitive, not {v!r}")
out[field] = v
elif field in ("geo_trigger_ips", "geo_alarm_ips"):
if field == "geo_alarm_ips" and not S3_ALARM_WRITE_MEASURED:
raise SettingsValueError("the alarm level is shown but not changed yet: a MiniMate "
"alarm write has never been measured (the bench measures it)")
x = _number(field, v)
if not TRIGGER_MIN <= x <= TRIGGER_MAX:
raise SettingsValueError(f"{field} must be {TRIGGER_MIN}-{TRIGGER_MAX} in/s, not {x}")
if abs(x - round(x, 3)) > 1e-9:
raise SettingsValueError(f"{field} must be in steps of {TRIGGER_STEP} in/s, not {x}")
out[field] = round(x, 3)
elif field == "record_time_s":
out[field] = _number(field, v)
elif field == "job_number":
if not JOB_MIN <= _integer(field, v) <= JOB_MAX:
raise SettingsValueError(f"job_number must be {JOB_MIN}-{JOB_MAX}, not {v}")
out[field] = v
elif field == "job_number_shown":
if not isinstance(v, bool):
raise SettingsValueError(f"job_number_shown must be true or false, not {v!r}")
out[field] = v
else: # note_1 .. note_4
if not isinstance(v, str):
raise SettingsValueError(f"{field} must be text, not {v!r}")
if any(not 0x20 <= ord(ch) <= 0x7E for ch in v):
raise SettingsValueError(f"{field} must be plain printable ASCII (no accents, tabs or "
"line breaks)")
if len(v) > NOTE_MAX:
raise SettingsValueError(f"{field} is {len(v)} characters; the unit holds {NOTE_MAX}")
out[field] = v
# What depends on this unit's block, with the NEW mode / rate / range if they change
# too -- checked on the block that would RESULT, so a one-field change (the range,
# the rate, the mode) cannot leave a value the unit already holds over its limit
# (final review, 2026-11-03).
c = content
if any(f in out for f in ("record_time_s", "sample_rate", "record_mode")):
t = out.get("record_time_s", _shown(_f32(c, _RECORD_TIME)))
held = "" if "record_time_s" in out else f" (the unit holds {t:g} s; change the record time too)"
if series == 4:
top: Optional[float] = S4_MAX_RECORD_S
else:
rate = out.get("sample_rate", int.from_bytes(c[_SAMPLE_RATE], "big"))
top = _s3_max_record(rate, out.get("record_mode", _mode_name(c, series)))
if top is None:
raise SettingsValueError(f"this unit's sample rate ({rate}) has no record-time limit "
"in the manual -- set the sample rate too")
if not RECORD_MIN_S <= t <= top:
raise SettingsValueError(f"record_time_s must be {RECORD_MIN_S}-{top:g} s here, not {t}{held}")
if any(f in out for f in (*_LEVELS, "geo_range")):
units = _unit_string(c)
if any(u != "in" for u in units):
raise SettingsValueError(f"this unit's geophone channels read {units}, not in/s -- only "
"in/s is measured, so SFM will not change a level or the range")
full = _full_scale(c, series, out.get("geo_range"))
if full is None:
raise SettingsValueError("this unit's geophone range byte is not a value ever measured")
held_levels = {"geo_trigger_ips": _CH_TRIGGER, "geo_alarm_ips": _CH_ALARM}
for f in _LEVELS:
if f not in _SERIES_FIELDS[series]:
continue
v = out.get(f, _shown(_f32(c, _ch(0) + held_levels[f])))
if v > full:
held = "" if f in out else " (the unit holds it)"
raise SettingsValueError(f"{f} {v} in/s is above the range's full scale ({full} in/s){held}")
return out
# ── Writing ─────────────────────────────────────────────────────────────────
def encode_setup(content: bytes, series: int, changes: Dict[str, Any]) -> bytes:
"""`content` with only the changed fields' bytes moved. `changes` should
come from check_changes; this patches, it does not judge. Bit fields are
patched bit by bit. Series 3 also writes Blastware's fixed bytes; Series 4
gets its checksum recomputed."""
out = bytearray(content)
for field, v in changes.items():
if field == "record_mode":
out[_MODE] = MODES[series][v]
elif field == "sample_rate":
out[_SAMPLE_RATE] = int(v).to_bytes(2, "big")
elif field == "histogram_interval_s":
out[_HIST_INTERVAL] = int(v).to_bytes(2, "big")
elif field == "record_time_s":
struct.pack_into(">f", out, _RECORD_TIME, float(v))
elif field == "geo_trigger_ips":
for k in _GEOPHONES:
struct.pack_into(">f", out, _ch(k) + _CH_TRIGGER, float(v))
elif field == "geo_alarm_ips":
for k in _GEOPHONES:
struct.pack_into(">f", out, _ch(k) + _CH_ALARM, float(v))
elif field == "geo_range":
for k in _GEOPHONES:
out[_ch(k) + _CH_RANGE] = _RANGES[v]
elif field == "job_number":
out[_JOB_NUMBER] = int(v).to_bytes(2, "big")
elif field == "job_number_shown":
out[_REPORT_FLAGS] = (out[_REPORT_FLAGS] | _JOB_SHOWN) if v else (out[_REPORT_FLAGS] & ~_JOB_SHOWN)
elif field.startswith("note_") and field[5:].isdigit() and 1 <= int(field[5:]) <= _NOTES:
_, start = _note_offsets(int(field[5:]) - 1)
out[start:start + _NOTE_WIDTH] = v.encode("ascii").ljust(_NOTE_WIDTH, b"\x00")
else:
raise SettingsValueError(f"{field} is not a setting SFM can change")
if series == 3:
for offset, value in S3_BLASTWARE_FIXED.items():
out[offset:offset + len(value)] = value
return bytes(out)
return with_crc(bytes(out))
# ── Reading back ────────────────────────────────────────────────────────────
_COMPARED = 2090
def settings_state(before: bytes, written: bytes, now: bytes, *, series: int) -> str:
"""What a read of the unit says about a change, from the bytes alone:
"as asked" (it holds what was written), "unchanged" (it holds what it had),
or "differs". Floats are never compared -- 0.3 is the same f32 both ways.
Series 4 also needs the unit's own checksum to hold. Series 3 bytes that
differ only in Blastware's fixed bytes count as as asked: nothing the operator
asked for is different."""
a, w, n = before[:_COMPARED], written[:_COMPARED], now[:_COMPARED]
if series == 4 and not crc_ok(now):
return "differs"
if n == w:
return "as asked"
if series == 3:
fixed = {o + i for o, v in S3_BLASTWARE_FIXED.items() for i in range(len(v))}
if len(n) == len(w) and all(n[i] == w[i] for i in range(len(n)) if i not in fixed):
return "as asked"
if n == a:
return "unchanged"
return "differs"
def revision(blocks: List[bytes]) -> str:
"""A short fingerprint of the blocks a preview read; a live change must match it."""
return hashlib.sha256(b"".join(bytes(b) for b in blocks)).hexdigest()[:16]
def changes_bytes(changes: Dict[str, Any]) -> bytes:
"""The normalised changes, canonically: part of a preview's revision, so a live
change must ask for exactly what was previewed (final review, 2026-11-03)."""
import json
return json.dumps(changes, sort_keys=True, separators=(",", ":")).encode("ascii")
+9 -6
View File
@@ -22,6 +22,7 @@ from .opcodes import CROSS_SERIES_COLLISIONS, WRITE_SUBS, OpcodeRefused
from .setup_block import crc_ok
_CONFIRM = 0xFFFF
_CALL_HOME_OBSERVED = (0x00, 0x01, 0x04, 0x05) # content[5] values units have held
# block content sizes THOR's offsets were observed at (all on UM12947 / 11.0CB)
_PREFS_LEN, _TRIGGER_LEN, _SETUP_LEN, _CALL_HOME_LEN = 90, 28, 2092, 126
@@ -113,9 +114,10 @@ def plan_call_home_enabled(call_home: bytes, enabled: bool) -> WritePlan:
Bit 0 of `[5]` is the enable. 🔶 UM12947 (THOR's unit) read 0x05 enabled /
0x04 disabled, bit 2 set in both; UM20147 reads 0x01 (measured, phase-2 dry
run). So on UM20147 "off" writes 0x00, a value no capture shows being
written: the target value there is unobserved, and the plan's `warnings`
say so. `[118:120]` is unit-maintained and THOR echoes it.
run). So on UM20147 "off" writes 0x00 -- measured at the bench 2026-11-03
(and again 11-04): 0x01 <-> 0x00 acknowledged, read back, and matched in the
unit's own menu. A value outside those four still carries a warning.
`[118:120]` is unit-maintained and THOR echoes it.
"""
if len(call_home) != _CALL_HOME_LEN:
raise ValueError(f"call-home content must be {_CALL_HOME_LEN} B "
@@ -128,9 +130,10 @@ def plan_call_home_enabled(call_home: bytes, enabled: bool) -> WritePlan:
what = "call-home " + ("enable" if enabled else "disable")
start = call_home[5]
warnings = []
if start not in (0x04, 0x05) or b5 not in (0x04, 0x05):
warnings.append(f"content[5] 0x{start:02X} -> 0x{b5:02X}: THOR was only ever "
"seen writing 0x04/0x05 (UM12947); this value is unobserved")
if start not in _CALL_HOME_OBSERVED or b5 not in _CALL_HOME_OBSERVED:
warnings.append(f"content[5] 0x{start:02X} -> 0x{b5:02X}: no unit has been seen "
"holding this value (0x04/0x05 UM12947 by THOR, 0x00/0x01 UM20147 "
"by SFM); it is unobserved")
if b5 == start:
warnings.append(f"the unit is already call-home {'enabled' if enabled else 'disabled'}"
" -- this write changes nothing")
+33 -376
View File
@@ -70,15 +70,8 @@ S3_MONITORING_FLAGS = frozenset({0x10, 0x0B})
# ⚠ RETRACTED 2026-10-27 (#46): a trigger block "hardcoded from 3-11-26 -- no
# read exists, Blastware writes this fixed blob". Blastware reads it first (SUB
# 0x2E), and its byte 5 differs by unit and session (01 / 03 / 04 on record), so
# the copy changed that setting on any unit that differed. apply_config reads
# the unit's own block (MiniMateProtocol.read_trigger_config).
# Compliance ASCII slot format (confirmed from 3-11-26 capture + label search):
# Each label occupies a 64-byte slot.
# Value starts at slot_start + 22, max 42 bytes, null-padded.
_COMPLIANCE_SLOT_SIZE = 64
_COMPLIANCE_VALUE_OFFSET = 22
_COMPLIANCE_VALUE_MAX = _COMPLIANCE_SLOT_SIZE - _COMPLIANCE_VALUE_OFFSET # 42
# the copy changed that setting on any unit that differed. A settings write sends
# the unit's own block back (sfm.device_access.s3 change_settings, phase 5).
# ── MiniMateClient ────────────────────────────────────────────────────────────
@@ -922,6 +915,8 @@ class MiniMateClient:
compliance_data: bytes,
trigger_data: bytes,
waveform_data: bytes,
*,
escaped: bool = False,
) -> None:
"""
Push a complete config update to the device using the confirmed write
@@ -949,6 +944,10 @@ class MiniMateClient:
trigger_data: Raw bytes for SUB 82 write (44-byte trigger config).
waveform_data: Raw bytes for SUB 69 write.
`escaped`: False (the default) -- the blocks are logical, as every block
read returns them since phase 5; True for blocks that still hold the
parser's kept escape bytes.
Raises:
RuntimeError: if the client is not connected.
ProtocolError: if any write step fails (timeout, bad ack SUB).
@@ -960,32 +959,36 @@ class MiniMateClient:
# 2026-10-27): a block refused after 68 + 73 had been sent left a partial
# write behind. write_image is the same check each write makes.
from .protocol import (SUB_COMPLIANCE_WRITE, SUB_EVENT_INDEX_WRITE,
SUB_TRIGGER_CONFIG_WRITE, SUB_WAVEFORM_DATA_WRITE, write_image)
SUB_TRIGGER_CONFIG_WRITE, SUB_WAVEFORM_DATA_WRITE, ImageRefused,
write_image)
for sub, data in ((SUB_EVENT_INDEX_WRITE, event_index_data),
(SUB_COMPLIANCE_WRITE, compliance_data),
(SUB_TRIGGER_CONFIG_WRITE, trigger_data),
(SUB_WAVEFORM_DATA_WRITE, waveform_data)):
write_image(sub, data)
try:
write_image(sub, data, escaped=escaped)
except ValueError as exc: # refused before any frame: the caller audits "nothing sent"
raise ImageRefused(str(exc)) from exc
# 68 → 73
log.info("push_config_raw: write event index (SUB 68)")
proto.write_event_index(event_index_data)
proto.write_event_index(event_index_data, escaped=escaped)
log.info("push_config_raw: confirm B (SUB 73)")
proto.write_confirm(SUB_WRITE_CONFIRM_B)
# 71×3 → 72 (handled internally by write_compliance_config_raw)
log.info("push_config_raw: write compliance config (SUB 71 ×3 + confirm 72)")
proto.write_compliance_config_raw(compliance_data)
proto.write_compliance_config_raw(compliance_data, escaped=escaped)
# 82 → 83
log.info("push_config_raw: write trigger config (SUB 82)")
proto.write_trigger_config(trigger_data)
proto.write_trigger_config(trigger_data, escaped=escaped)
log.info("push_config_raw: trigger confirm (SUB 83)")
proto.write_confirm(SUB_TRIGGER_CONFIRM)
# 69 → 74 → 72
log.info("push_config_raw: write waveform data (SUB 69)")
proto.write_waveform_data(waveform_data)
proto.write_waveform_data(waveform_data, escaped=escaped)
log.info("push_config_raw: confirm C (SUB 74)")
proto.write_confirm(SUB_WRITE_CONFIRM_C)
log.info("push_config_raw: confirm A (SUB 72)")
@@ -993,120 +996,6 @@ class MiniMateClient:
log.info("push_config_raw: complete")
def apply_config(
self,
*,
# Recording parameters
recording_mode: Optional[int] = None,
sample_rate: Optional[int] = None,
record_time: Optional[float] = None,
histogram_interval_sec: Optional[int] = None,
# Threshold parameters (geo channels, in/s)
trigger_level_geo: Optional[float] = None,
alarm_level_geo: Optional[float] = None,
geo_range: Optional[int] = None, # 0x00=Normal 10in/s, 0x01=Sensitive 1.25in/s
# Project / operator strings
project: Optional[str] = None,
client_name: Optional[str] = None,
operator: Optional[str] = None,
seis_loc: Optional[str] = None,
notes: Optional[str] = None,
) -> None:
"""
Read the current device config, apply any supplied changes to the
compliance block, and write the full config back to the device.
Only non-None arguments are modified; all other bytes are round-tripped
verbatim from the device.
Configurable fields
-------------------
Recording parameters:
recording_mode : int — 0x00=Single Shot, 0x01=Continuous, 0x03=Histogram, 0x04=Histogram+Continuous
sample_rate : int — samples/sec; valid values: 1024, 2048, 4096
record_time : float — record duration in seconds (e.g. 2.0, 3.0)
Trigger/alarm thresholds and range (geo channels):
trigger_level_geo : float — trigger threshold in/s (e.g. 0.5)
alarm_level_geo : float — alarm threshold in/s (e.g. 1.0)
geo_range : int — 0x00=Normal 10.000 in/s, 0x01=Sensitive 1.250 in/s
(written to Tran/Vert/Long channel blocks)
Project / operator strings (max 41 ASCII characters each):
project : str
client_name : str
operator : str
seis_loc : str — sensor location
notes : str — extended notes
Write sequence (confirmed from 3-11-26 BW TX capture):
68→73 | 71×3→72 | 82→83 | 69→74→72
Write payloads:
event_index_data : 88 bytes — read live via SUB 08
compliance_data : ~2128 bytes — read live via SUB 1A (~2126 bytes, varies ±1-2) + \\x00\\x00 footer
trigger_data : 26 bytes — read live via SUB 2E (was hard-coded; #46)
waveform_data : 204 bytes — read live via SUB 09
Raises:
RuntimeError: if not connected.
ProtocolError: if any read or write step fails.
ValueError: if compliance buffer is shorter than the 2082-byte write minimum.
"""
proto = self._require_proto()
# 1. Read current payloads from the device
log.info("apply_config: reading event index (SUB 08)")
event_index_data = proto.read_event_index()
log.info("apply_config: reading compliance config (SUB 1A)")
compliance_raw = proto.read_compliance_config() # ~2126 bytes (varies ±1-2 by DLE jitter)
log.info("apply_config: reading waveform data (SUB 09)")
waveform_data = proto.read_waveform_data_raw() # 204 bytes
log.info("apply_config: reading trigger config (SUB 2E)")
trigger_data = proto.read_trigger_config() # 26 bytes, this unit's own
# 2. Patch the compliance buffer and build the 2128-byte write payload
compliance_data = _encode_compliance_config(
compliance_raw,
recording_mode=recording_mode,
sample_rate=sample_rate,
record_time=record_time,
histogram_interval_sec=histogram_interval_sec,
trigger_level_geo=trigger_level_geo,
alarm_level_geo=alarm_level_geo,
geo_range=geo_range,
project=project,
client_name=client_name,
operator=operator,
seis_loc=seis_loc,
notes=notes,
)
log.info("apply_config: compliance payload ready (%d bytes)", len(compliance_data))
# 3. Push the full write sequence to the device
self.push_config_raw(event_index_data, compliance_data, trigger_data, waveform_data)
log.info("apply_config: complete")
def set_project_info(
self,
project: Optional[str] = None,
client_name: Optional[str] = None,
operator: Optional[str] = None,
seis_loc: Optional[str] = None,
notes: Optional[str] = None,
) -> None:
"""Backwards-compat shim — delegates to apply_config()."""
self.apply_config(
project=project,
client_name=client_name,
operator=operator,
seis_loc=seis_loc,
notes=notes,
)
# ── Call home config ──────────────────────────────────────────────────────
def get_call_home_config(self) -> CallHomeConfig:
@@ -1132,6 +1021,21 @@ class MiniMateClient:
read-modify-write (`call_home_image`)."""
return self._require_proto().read_call_home_config()
def read_compliance_content(self) -> bytes:
"""The 1A settings read as the logical 2,090-byte block, unjudged (a
monitoring unit's device-info answer comes back as it is; see
`minimateplus.protocol.is_compliance_content`)."""
return self._require_proto().read_compliance_content()
def read_settings_blocks(self) -> dict:
"""The four blocks a settings write sends back, each as its read returns it:
event index (08), settings (1A, logical), trigger (2E), waveform data (09)."""
proto = self._require_proto()
return {"event_index": proto.read_event_index(),
"compliance": proto.read_compliance_content(),
"trigger": proto.read_trigger_config(),
"waveform": proto.read_waveform_data_raw()}
def write_call_home_image(self, image: bytes) -> None:
"""Send a `0x7E` image (`call_home_image`) and its `0x7F` confirm, each ack
checked -- framed once, never unescaped again. Raises ImageRefused before
@@ -2108,253 +2012,6 @@ def _extract_project_strings(data: bytes) -> Optional[ProjectInfo]:
)
def _encode_compliance_config(
raw: bytes,
*,
recording_mode: Optional[int] = None,
sample_rate: Optional[int] = None,
record_time: Optional[float] = None,
trigger_level_geo: Optional[float] = None,
alarm_level_geo: Optional[float] = None,
geo_range: Optional[int] = None, # 0x00=Normal 10in/s, 0x01=Sensitive 1.25in/s
histogram_interval_sec: Optional[int] = None,
project: Optional[str] = None,
client_name: Optional[str] = None,
operator: Optional[str] = None,
seis_loc: Optional[str] = None,
notes: Optional[str] = None,
) -> bytes:
"""
Patch a live 2126-byte compliance buffer (read from the device) with any
supplied field values and return the 2128-byte write payload.
Only non-None arguments are modified; everything else is round-tripped verbatim.
Numeric field locations (all anchor-relative or label-relative — immune to
DLE-jitter shifts):
Anchor: b'\\xbe\\x80\\x00\\x00\\x00\\x00' (confirmed stable, both BE11529 and BE18189)
⚠ 2026-10-29: these RAW offsets were measured at 1024 sps, where the escape
before `04` sits between the mode and the anchor. The decoder now reads
the four fields after unescaping (mode -7, rate -6, interval -4, record
time +6), so at any other layout these patch the wrong bytes. Until the
encoder is rewritten on unescaped bytes (#46), a payload whose four fields
do not read back as asked raises ValueError -- see the end of this function.
recording_mode → uint8 at anchor_pos - 8 (raw; right at 1024 sps only)
Values: 0x00=Single Shot, 0x01=Continuous, 0x03=Histogram, 0x04=Histogram+Continuous
NOTE: The byte at anchor_pos - 7 is always 0x10 (a DLE marker regenerated by
device firmware in every E5 response). It must NOT be overwritten during
write — doing so causes anchor drift (+1 per write cycle).
CORRECTION 2026-04-21: previous doc stated anchor-7 for write; empirically
confirmed wrong — writing to anchor-7 shifts the anchor by 1 on every cycle.
sample_rate → uint16 BE at anchor_pos - 6
histogram_interval_sec → uint16 BE at anchor_pos - 4 (seconds; mode-gated to Histogram/Histogram+Continuous)
Valid values: 2, 5, 15, 60, 300, 900 (= 2s, 5s, 15s, 1m, 5m, 15m)
record_time → float32 BE at anchor_pos + 6
Channel block (anchored on b"Tran" with unit-string guard):
geo_range → uint8 at tran_pos + 33 (confirmed 2026-04-20)
0x00 = Normal 10.000 in/s, 0x01 = Sensitive 1.250 in/s
Written to Tran, Vert, Long channel blocks (all three).
adc_scale_factor → float32 BE at tran_pos + 28 (= 6.206053; do NOT write)
trigger_level_geo → float32 BE at tran_pos + 34
"in.\\x00" → unit string at tran_pos + 38 (layout guard)
alarm_level_geo → float32 BE at tran_pos + 42
"/s\\x00\\x00" → unit string at tran_pos + 46 (layout guard)
NOTE: tran_pos+28 (float32 = 6.206053) is the ADC-to-velocity scale factor
(= 1/sensitivity, (in/s)/V — Interface Handbook §4.5: 1.61133 V × 6.206053 = 10.000 in/s).
This is a hardware/firmware constant common to all MiniMate Plus S3 units.
It must NOT be written — do not add it back as a parameter.
String field locations (64-byte slots, label+22 format):
b"Project:" → value at label_pos + 22, max 41 chars + null
b"Client:" → value at label_pos + 22, max 41 chars + null
b"User Name:" → value at label_pos + 22, max 41 chars + null
b"Seis Loc:" → value at label_pos + 22, max 41 chars + null
b"Extended Notes"→ value at label_pos + 22, max 41 chars + null
Returns:
2128-byte write payload: patched 2126-byte buffer + 2-byte footer \\x00\\x00.
(Checksum formula for the footer is unknown; \\x00\\x00 confirmed accepted
by the device in POC test 2026-04-07.)
Raises:
ValueError: if raw is shorter than the minimum needed for the 3-chunk write.
"""
# Total size is nominally ~2126 bytes but varies by ±1-2 bytes depending on
# DLE jitter in the E5 read response (0x10 bytes in the config data cause
# 1-byte expansions per occurrence during DLE stuffing/unstuffing). The
# anchor-based field access and the chunk splitter (fixed chunk1=1027,
# chunk2=1055, chunk3=remainder) both handle variable length correctly.
# Only enforce a minimum — must have at least chunk1+chunk2 bytes of content.
_MIN_COMPLIANCE_LEN = 1027 + 1055 # = 2082
if len(raw) < _MIN_COMPLIANCE_LEN:
raise ValueError(
f"_encode_compliance_config: compliance buffer too short "
f"({len(raw)} bytes, need at least {_MIN_COMPLIANCE_LEN})"
)
if len(raw) not in range(2124, 2132):
log.warning(
"_encode_compliance_config: unusual compliance buffer length %d "
"(expected ~2126); proceeding with anchor-based access",
len(raw),
)
buf = bytearray(raw)
# ── Numeric: recording_mode + sample_rate + record_time (anchor-relative) ──
_ANC = b'\xbe\x80\x00\x00\x00\x00'
_anc = buf.find(_ANC, 0, 150)
# Log anchor position every time so we can detect unexpected shifts due to
# DLE jitter or firmware differences. Expected position is ~15.
if _anc < 0:
log.warning(
"_encode_compliance_config: anchor NOT FOUND in cfg[0:150] "
"(buf len=%d) — all anchor-relative writes will be skipped",
len(buf),
)
else:
log.info(
"_encode_compliance_config: anchor at cfg[%d] buf_len=%d "
"(recording_mode@%d DLE_marker@%d sample_rate@%d:%d "
"histogram_interval@%d:%d record_time@%d:%d)",
_anc, len(buf),
_anc - 8,
_anc - 7,
_anc - 6, _anc - 4,
_anc - 4, _anc - 2,
_anc + 6, _anc + 10,
)
if recording_mode is not None:
if _anc < 8:
log.warning("_encode_compliance_config: anchor not found — cannot write recording_mode")
else:
# Write to anchor-8, same physical position as the E5 read format.
# The byte at anchor-7 is a DLE marker (0x10) that the device firmware
# regenerates in every E5 response — it must NOT be overwritten.
# Writing to anchor-7 causes the device to add an extra byte on the
# next read-back, drifting the anchor by +1 on every write cycle.
# (CLAUDE.md "anchor-7 write" was incorrect — confirmed 2026-04-21)
buf[_anc - 8] = recording_mode & 0xFF
log.debug("_encode_compliance_config: recording_mode=0x%02X -> offset %d",
recording_mode, _anc - 8)
if sample_rate is not None:
if _anc < 6:
log.warning("_encode_compliance_config: anchor not found — cannot write sample_rate")
else:
struct.pack_into(">H", buf, _anc - 6, sample_rate)
log.debug("_encode_compliance_config: sample_rate=%d -> offset %d", sample_rate, _anc - 6)
if histogram_interval_sec is not None:
if _anc < 4:
log.warning("_encode_compliance_config: anchor not found — cannot write histogram_interval")
else:
struct.pack_into(">H", buf, _anc - 4, histogram_interval_sec)
log.debug("_encode_compliance_config: histogram_interval=%ds -> offset %d",
histogram_interval_sec, _anc - 4)
if record_time is not None:
if _anc < 0 or _anc + 10 > len(buf):
log.warning("_encode_compliance_config: anchor not found — cannot write record_time")
else:
struct.pack_into(">f", buf, _anc + 6, record_time)
log.debug("_encode_compliance_config: record_time=%.3f -> offset %d", record_time, _anc + 6)
# ── Numeric: channel block (Tran label + unit-string guard) ───────────────
# NOTE: tran_pos+24 (write format) or tran_pos+28 (E5 read format) is the
# ADC-to-velocity scale factor (6.206053, hardware constant — never written).
# geo_range is written to ALL THREE geo channel blocks (Tran, Vert, Long),
# confirmed from 4-20-26 captures showing the byte at label+29 in each block.
_needs_channel = any(v is not None for v in (trigger_level_geo, alarm_level_geo, geo_range))
if _needs_channel:
_tran = buf.find(b"Tran", 44)
_valid = (
_tran >= 0
and buf[_tran + 4 : _tran + 5] != b"2"
and _tran + 50 <= len(buf)
and buf[_tran + 38 : _tran + 42] == b"in.\x00"
and buf[_tran + 46 : _tran + 50] == b"/s\x00\x00"
)
if not _valid:
log.warning(
"_encode_compliance_config: 'Tran' channel block not found or unit "
"guard failed — trigger/alarm/geo_range will not be written"
)
else:
if trigger_level_geo is not None:
struct.pack_into(">f", buf, _tran + 34, trigger_level_geo)
log.debug("_encode_compliance_config: trigger_level_geo=%.4f -> offset %d", trigger_level_geo, _tran + 34)
if alarm_level_geo is not None:
struct.pack_into(">f", buf, _tran + 42, alarm_level_geo)
log.debug("_encode_compliance_config: alarm_level_geo=%.4f -> offset %d", alarm_level_geo, _tran + 42)
if geo_range is not None:
# Write geo_range to all three geo channel blocks (Tran, Vert, Long).
# Field at label+33 in the E5-format compliance bytes (same in read and write
# since the 2126-byte payload is round-tripped verbatim).
# 0x00 = Normal 10.000 in/s, 0x01 = Sensitive 1.250 in/s.
for _ch_label in (b"Tran", b"Vert", b"Long"):
_ch = buf.find(_ch_label, 44)
if _ch >= 0 and buf[_ch + 4 : _ch + 5] != b"2" and _ch + 34 <= len(buf):
buf[_ch + 33] = geo_range & 0xFF
log.debug(
"_encode_compliance_config: geo_range=0x%02X -> %s+33 offset %d",
geo_range, _ch_label.decode(), _ch + 33,
)
# ── ASCII strings (64-byte slot, value at label_pos+22) ───────────────────
def _set_string(label: bytes, value: Optional[str]) -> None:
if value is None:
return
idx = buf.find(label)
if idx < 0:
log.warning("_encode_compliance_config: label %r not found", label)
return
val_bytes = value.encode("ascii", errors="replace")[:_COMPLIANCE_VALUE_MAX - 1]
padded = val_bytes + b"\x00" * (_COMPLIANCE_VALUE_MAX - len(val_bytes))
buf[idx + _COMPLIANCE_VALUE_OFFSET : idx + _COMPLIANCE_SLOT_SIZE] = padded
log.debug("_encode_compliance_config: %r -> %r", label, value)
_set_string(b"Project:", project)
_set_string(b"Client:", client_name)
_set_string(b"User Name:", operator)
_set_string(b"Seis Loc:", seis_loc)
_set_string(b"Extended Notes", notes)
# ── Read-back check: the payload must decode to what was asked ────────────
# The decoder is the measured layout (every recorded reply); these offsets are
# 1024-sps raw ones. A mode change on BE9441's 10-25 Continuous / 4096 block
# rewrote the byte in front of the mode and read back unchanged. Refuse it
# here, before push_config_raw sends anything.
asked = {"recording_mode": recording_mode, "sample_rate": sample_rate,
"histogram_interval_sec": histogram_interval_sec, "record_time": record_time}
if any(v is not None for v in asked.values()):
before, after = _settings_read_back(raw), _settings_read_back(bytes(buf))
if record_time is not None:
asked["record_time"] = struct.unpack(">f", struct.pack(">f", record_time))[0]
want = {k: (v if v is not None else before[k]) for k, v in asked.items()}
wrong = {k: (after[k], want[k]) for k in asked if after[k] != want[k]}
if wrong:
raise ValueError(
"_encode_compliance_config: the patched block would not read back as asked ("
+ ", ".join(f"{k} reads {got!r}, not {exp!r}" for k, (got, exp) in wrong.items())
+ ") -- refused, nothing built or sent. The encoder's offsets were measured at "
"1024 sps and need rewriting on unescaped bytes (#46)."
)
# 2-byte footer — checksum formula unknown; \x00\x00 confirmed accepted by device
return bytes(buf) + b"\x00\x00"
def _settings_read_back(data: bytes) -> dict:
"""Mode, sample rate, interval and record time as the decoder reads `data`."""
info = DeviceInfo(serial="", firmware_minor=0)
_decode_compliance_config_into(data, info)
cc = info.compliance_config
return {k: getattr(cc, k, None) if cc is not None else None
for k in ("recording_mode", "sample_rate", "histogram_interval_sec", "record_time")}
def _decode_compliance_config_into(data: bytes, info: DeviceInfo) -> None:
+143 -16
View File
@@ -13,13 +13,16 @@ Pure: no I/O, and no import from `sfm/`.
"""
from __future__ import annotations
import datetime
import math
import re
from dataclasses import dataclass
from dataclasses import dataclass, field
from typing import Callable, Optional, Sequence
from .bw_xml_report import XmlReport
from .event_file_io import (_GEO_FS_BY_RANGE, _GEO_INT16_FS, _GEO_NORMAL_FS_INS, _MIC_PSI_PER_COUNT,
from .event_file_io import (interval_times, _GEO_FS_BY_RANGE, _GEO_INT16_FS, _GEO_NORMAL_FS_INS, _MIC_PSI_PER_COUNT,
decode_blastware_bytes)
from .histogram_codec import half_period_to_hz
from .models import Event
from .waveform_codec import mic_count_to_db
@@ -30,6 +33,50 @@ GEO_IPS_PER_COUNT: float = _GEO_NORMAL_FS_INS / _GEO_INT16_FS
_CHANNELS = ("Tran", "Vert", "Long", "MicL")
_EVENT_TYPE = {"Waveform": "Full Waveform", "Histogram": "Full Histogram"}
# How Blastware prints the setup fields SFM reads (measured 2026-11-03).
_MONTHS = ("January", "February", "March", "April", "May", "June", "July",
"August", "September", "October", "November", "December")
_TRIGGERED_BY = {0x0001: "Tran", 0x0002: "Vert", 0x0004: "Long", 0x0008: "MicL", 0x0200: "Manual"}
_STOP_MODES = {0: "Fixed"}
_MIC_TYPES = {2: "Linear Weighting"}
_GEO_TRIGGERS, _MIC_TRIGGER = 0x07, 0x08
# Blastware turns the mic trigger level from psi to dB with 6895 Pa per psi, not
# 6894.757: 4,272 / 4,272 DL2 levels against 4,271 (the odd one 0.01 psi,
# printed 130.8 dB(L), is 130.7498 at the exact constant).
_TRIGGER_PA_PER_PSI = 6895.0
def _setup_values(ev: Event) -> dict[str, object]:
out: dict[str, object] = {}
di = ev.device_info
if di is not None:
out["SerialNumber"] = di.serial
fw = di.firmware_version or ""
if di.dsp_version and fw.startswith("S33") and di.model:
# "V 10.72-8.17 MiniMate Plus" from "10.72", "S338.17" and the model --
# the only version in DL2, so the rule is proven for it alone.
out["Version"] = f"V {di.dsp_version}-{fw[3:]} {di.model}"
if di.calibration_date and di.calibrated_by:
c = di.calibration_date
out["Calibration"] = f"{_MONTHS[c.month - 1]} {c.day}, {c.year} by {di.calibrated_by}"
out["BatteryLevel"] = ev.battery_volts
out["Trigger"] = _TRIGGERED_BY.get(ev.triggered_by)
out["RecordStopMode"] = _STOP_MODES.get(ev.record_stop_mode)
out["Microphone"] = _MIC_TYPES.get(ev.mic_type)
# dB or psi is Blastware's preference, not the unit's (carve-out
# units-is-a-display-preference); SFM reports dB, the default.
out["Units"] = "in/s and dB(L)" if ev.mic_type is not None else "in/s"
# Blastware prints a trigger level only for a channel that is a trigger
# source, and none for a Manual trigger.
src, manual = ev.trigger_sources or 0, ev.triggered_by == 0x0200
if src & _GEO_TRIGGERS and not manual:
out["GeoTriggerLevel"] = ev.trigger_level_geo
if src & _MIC_TRIGGER and not manual and ev.trigger_level_mic_psi:
psi = ev.trigger_level_mic_psi
out["MicTriggerLevel psi(L)"] = psi
out["MicTriggerLevel dB(L)"] = 20 * math.log10(psi * _TRIGGER_PA_PER_PSI / 2e-5)
return out
@dataclass
class SfmSide:
@@ -40,6 +87,27 @@ class SfmSide:
channels: list[str] # channels with decoded data, in Tran/Vert/Long/MicL order
counts: dict[str, list[int]] # waveform samples or histogram interval peaks
geo_ips_per_count: float = GEO_IPS_PER_COUNT # at the event's range, as SFM read it
# interval column -> SFM's value per interval (a number, or Blastware's word)
interval_values: dict[str, list[object]] = field(default_factory=dict)
interval_times: Optional[list[str]] = None # each interval's printed time
def interval_frequency(halfp: int, sample_rate: int) -> object:
"""An interval's frequency as Blastware prints it: "N/A" for a half-period
of 0, ">100" (">200" at 2048 sps) at 5 samples or fewer, "<1.0" below 1 Hz,
else (sample rate / 2) / half-period in Hz. Measured on ~3.1 M DL2 cells,
2026-11-03 (#50: the rate, not a fixed 512)."""
if halfp == 0:
return "N/A"
hz = half_period_to_hz(halfp, sample_rate)
if hz is None:
return f">{round(100 * sample_rate / 1024)}"
return "<1.0" if hz < 1.0 else hz
def _interval_size(seconds: int) -> str:
n, unit = (seconds // 60, "minute") if seconds % 60 == 0 else (seconds, "second")
return f"{n} {unit}{'' if n == 1 else 's'}"
def sfm_side(raw: bytes) -> SfmSide:
@@ -69,9 +137,46 @@ def sfm_side(raw: bytes) -> SfmSide:
if pv is not None:
values.update(TranPPV=pv.tran, VertPPV=pv.vert, LongPPV=pv.long,
PeakVectorSum=pv.peak_vector_sum)
# A waveform's peak detail (None on a histogram, so not reported).
for tag, value in (("TranTimeofPeak", pv.tran_time_of_peak),
("VertTimeofPeak", pv.vert_time_of_peak),
("LongTimeofPeak", pv.long_time_of_peak),
("MicLTimeofPeak", pv.micl_time_of_peak),
("PeakVectorSumTimeSum", pv.pvs_time),
("TranPeakAcceleration", pv.tran_peak_accel_g),
("VertPeakAcceleration", pv.vert_peak_accel_g),
("LongPeakAcceleration", pv.long_peak_accel_g)):
if value is not None:
values[tag] = value
if counts["MicL"]:
values["MicLPSPL dB(L)"] = mic_count_to_db(max(abs(c) for c in counts["MicL"]))
values["MicLPSPL psi(L)"] = pv.micl if pv is not None else None
values.update(_setup_values(ev))
if ev.stop_time is not None:
values.update(HistogramStopDate=ev.stop_time.strftime("%Y-%m-%d"),
HistogramStopTime=ev.stop_time.strftime("%H:%M:%S"))
if ev.histogram_interval_sec:
values["IntervalSize"] = _interval_size(ev.histogram_interval_sec)
interval_values: dict[str, list[object]] = {}
if ev.interval_half_periods and ev.sample_rate:
for ch, hps in ev.interval_half_periods.items():
interval_values[f"{ch} Freq Hz"] = [interval_frequency(h, ev.sample_rate) for h in hps]
if ev.interval_pvs:
interval_values["Geo PVS in/s"] = list(ev.interval_pvs)
times = None
n = len(counts["Tran"])
if ev.record_type == "Histogram" and ts is not None and ev.histogram_interval_sec and n:
start = datetime.datetime(ts.year, ts.month, ts.day, ts.hour, ts.minute, ts.second)
ends = interval_times(start, ev.histogram_interval_sec, ev.stop_time, n)
times = [t.strftime("%Y-%m-%d %H:%M:%S") for t in ends]
# A peak's date and time are those of the interval holding it (first).
for tag, series in (("TranPeak", counts["Tran"]), ("VertPeak", counts["Vert"]),
("LongPeak", counts["Long"]), ("MicL", counts["MicL"]),
("PeakVectorSum", ev.interval_pvs)):
if series and len(series) == n:
j = max(range(n), key=lambda q: abs(series[q]))
values[f"{tag}Date"] = ends[j].strftime("%Y-%m-%d")
values[f"{tag}Time"] = ends[j].strftime("%H:%M:%S")
return SfmSide(
event=ev,
@@ -82,6 +187,8 @@ def sfm_side(raw: bytes) -> SfmSide:
channels=[ch for ch in _CHANNELS if counts[ch]],
counts=counts,
geo_ips_per_count=_GEO_FS_BY_RANGE.get(ev.geo_range, _GEO_NORMAL_FS_INS) / _GEO_INT16_FS,
interval_values=interval_values,
interval_times=times,
)
@@ -144,10 +251,12 @@ def _mic_converter(ref: XmlReport) -> Optional[Callable[[int], float]]:
def _compare_scalar(tag: str, printed: str, sfm: SfmSide, ref: XmlReport) -> FieldResult:
if not printed.strip() or printed.strip() == "N/A":
return FieldResult(tag, "no_reference", printed, None)
if tag == "MicLPSPL":
units = ref.event_units or ""
key = ("MicLPSPL dB(L)" if "dB(L)" in units else
"MicLPSPL psi(L)" if "psi(L)" in units else None)
if tag in ("MicLPSPL", "MicTriggerLevel"):
# A printed value that states its unit is compared in that unit:
# K441LA17.IN0W's Units say psi(L), its MicTriggerLevel "125.0 dB(L)".
units = printed if ("dB(L)" in printed or "psi(L)" in printed) else (ref.event_units or "")
key = (f"{tag} dB(L)" if "dB(L)" in units else
f"{tag} psi(L)" if "psi(L)" in units else None)
value = sfm.values.get(key) if key else None
else:
value = sfm.values.get(tag)
@@ -166,9 +275,11 @@ def _compare_scalar(tag: str, printed: str, sfm: SfmSide, ref: XmlReport) -> Fie
return FieldResult(tag, "match" if ok else "mismatch", printed, _render(value, printed))
def _cell_diff(value: float, printed: str) -> Optional[float]:
def _cell_diff(value: object, printed: str) -> Optional[float]:
"""|value - printed| when the cell disagrees, else None; inf for a cell that
is not a number."""
is not a number. A word on SFM's side (">100", "N/A") must be printed."""
if isinstance(value, str):
return None if _same_text(value, printed) else float("inf")
p = _printed_number(printed)
if p is None:
return float("inf")
@@ -237,14 +348,19 @@ def series_pairs(sfm: SfmSide, ref: XmlReport,
if field.startswith("intervals."):
title = field[len("intervals."):]
columns = ref.interval_columns or []
convert = _interval_converter(title, sfm)
counts = sfm.counts.get(title.partition(" ")[0], [])
if convert is None or not counts or title not in columns:
if title not in columns:
return None
i = columns.index(title)
cells = [row[i] if i < len(row) else "" for _, row in (ref.intervals or [])]
pairs = [(j, cell, convert(c)) for j, (cell, c) in enumerate(zip(cells, counts))]
return pairs, abs(len(cells) - len(counts))
values = sfm.interval_values.get(title)
if values is None:
convert = _interval_converter(title, sfm)
counts = sfm.counts.get(title.partition(" ")[0], [])
if convert is None or not counts:
return None
values = [convert(c) for c in counts]
pairs = [(j, cell, v) for j, (cell, v) in enumerate(zip(cells, values))]
return pairs, abs(len(cells) - len(values))
return None
@@ -254,7 +370,9 @@ def _compare_series(field: str, n_bw: int, sfm: SfmSide, ref: XmlReport) -> Fiel
return FieldResult(field, "sfm_blank", f"{n_bw} rows", None)
pairs, row_len = got
diffs = [(j, d) for j, cell, v in pairs if (d := _cell_diff(v, cell)) is not None]
n_sfm = len(sfm.counts.get(field.split(".", 1)[1].partition(" ")[0], []))
title = field.split(".", 1)[1]
n_sfm = (len(sfm.interval_values[title]) if title in sfm.interval_values
else len(sfm.counts.get(title.partition(" ")[0], [])))
return _series_result(field, n_bw, n_sfm, diffs, row_len)
@@ -265,12 +383,21 @@ def _compare_samples(sfm: SfmSide, ref: XmlReport) -> list[FieldResult]:
def _compare_intervals(sfm: SfmSide, ref: XmlReport) -> list[FieldResult]:
"""One result per column, plus the interval times, which SFM does not keep."""
"""One result per column, plus the interval times."""
n = len(ref.intervals or [])
return ([FieldResult("intervals.Time", "sfm_blank", f"{n} rows", None)]
return ([_compare_interval_times(sfm, ref, n)]
+ [_compare_series(f"intervals.{t}", n, sfm, ref) for t in ref.interval_columns or []])
def _compare_interval_times(sfm: SfmSide, ref: XmlReport, n: int) -> FieldResult:
if sfm.interval_times is None:
return FieldResult("intervals.Time", "sfm_blank", f"{n} rows", None)
diffs = [(j, float("inf")) for j, ((t, _), s) in enumerate(zip(ref.intervals or [], sfm.interval_times))
if not _same_text(s, t)]
return _series_result("intervals.Time", n, len(sfm.interval_times), diffs,
abs(n - len(sfm.interval_times)))
def compare(sfm: SfmSide, ref: XmlReport, carveouts: Sequence["Carveout"] = ()) -> list[FieldResult]:
"""Every field Blastware's report carries, set against what SFM produced.
A mismatch a carve-out covers and applies to becomes `accepted`."""
+46 -3
View File
@@ -68,6 +68,21 @@ def _saturation(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool:
got = series_pairs(sfm, ref, res.field)
if got is None or got[1]:
return False
if res.field == "intervals.Geo PVS in/s":
# Per interval, as PeakVectorSum: an OORANGE vector sum, SFM's sum within
# three channels at the ceiling, and a channel Blastware itself clamped in
# that interval. 17 / 17 DL2 cells, SFM 10.01 .. 17.33 (2026-11-03).
cols = ref.interval_columns or []
peaks = [cols.index(c) for c in ("Tran Peak in/s", "Vert Peak in/s", "Long Peak in/s")
if c in cols]
rows = ref.intervals or []
differing = [(j, cell, v) for j, cell, v in got[0]
if isinstance(v, str) or not matches_printed(v, cell)]
return bool(differing) and all(
cell.strip() == "OORANGE" and not isinstance(v, str)
and r - _TOL <= v <= 3 ** 0.5 * r * 1.01
and any(_clamped(rows[j][1][p], r) for p in peaks if p < len(rows[j][1]))
for j, cell, v in differing)
differing = [(cell, v) for _, cell, v in got[0] if not matches_printed(v, cell)]
return bool(differing) and all(
_clamped(cell, r) and _at_ceiling(v, r)
@@ -79,10 +94,13 @@ SATURATION = Carveout(
id="saturation",
fields=("TranPPV", "VertPPV", "LongPPV", "PeakVectorSum",
"samples.Tran", "samples.Vert", "samples.Long",
"intervals.Tran Peak in/s", "intervals.Vert Peak in/s", "intervals.Long Peak in/s"),
"intervals.Tran Peak in/s", "intervals.Vert Peak in/s", "intervals.Long Peak in/s",
"intervals.Geo PVS in/s"),
evidence=("Blastware clamps a clipped channel to the range maximum and prints OORANGE; "
"the file holds counts past full scale (32016 counts = 10.005 in/s observed). "
"scratch/verify_against_ascii.py, 2026-08-28."),
"scratch/verify_against_ascii.py, 2026-08-28. An interval's vector sum prints "
"OORANGE when it exceeds the range in an interval with a clamped channel: 17 / 17 "
"DL2 cells, 2026-11-03."),
applies=_saturation,
)
@@ -106,4 +124,29 @@ INTERVAL_COUNT_IS_DURATION = Carveout(
applies=_interval_count_is_duration,
)
CARVEOUTS: tuple[Carveout, ...] = (SATURATION, INTERVAL_COUNT_IS_DURATION)
_MIC_UNITS = ("in/s and dB(L)", "in/s and psi(L)")
def _units_is_a_display_preference(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool:
"""Both sides say the event has a mic; they differ only in dB against psi."""
return (" ".join((res.bw or "").split()) in _MIC_UNITS
and sfm.values.get("Units") in _MIC_UNITS)
UNITS_IS_A_DISPLAY_PREFERENCE = Carveout(
id="units-is-a-display-preference",
fields=("Units",),
evidence=("dB(L) or psi(L) is Blastware's display preference on the PC when it wrote the "
"report, not the unit's: in report-write order (the _XML.XML mtimes) DL2's 70,034 "
"reports switch fleet-wide in 61 clean runs, every unit at once, and no byte or "
"bit of the event file separates the two (k-240 .. k+520, nor the 1.2 KB before "
"the footer). Instantel documents both settings: the unit's own Microphone "
"Units (MiniMate Plus manual 716U0101 Rev 15 §3.9.7: psi(L), dB(L) or Pa(L), "
"keypad Right Arrow + Setups) and Blastware's report preference (Blastware "
"manual 714U0301 Rev 22 §4, Preferences > Units and Channel: Show Mic in dB / "
"in Linear Units). 2026-11-03."),
applies=_units_is_a_display_preference,
)
CARVEOUTS: tuple[Carveout, ...] = (SATURATION, INTERVAL_COUNT_IS_DURATION,
UNITS_IS_A_DISPLAY_PREFERENCE)
+238 -28
View File
@@ -19,18 +19,19 @@ import datetime
import hashlib
import json
import logging
import math
import os
import re
import struct
from pathlib import Path
from typing import Optional, Union
from .models import Event, PeakValues, ProjectInfo, Timestamp
from .models import DeviceInfo, Event, PeakValues, ProjectInfo, Timestamp
from . import blastware_file as _bw # avoid circular reference at module load
from .bw_ascii_report import BwAsciiReport
from . import waveform_codec as _wc
from .waveform_codec import decode_waveform_v2, decoded_to_adc_counts
from .histogram_codec import decode_histogram_body, interval_pvs
from .histogram_codec import channels_from_records, decode_histogram_body, decode_histogram_body_full
# Reference pressure for dB(L) → psi conversion (20 µPa expressed in psi).
# Same constant as sfm/sfm_webapp.html so server-side and browser-side
@@ -51,7 +52,7 @@ SIDECAR_KIND = "sfm.event"
# bumped without a `pip install` re-run — leading to confusing stale
# version stamps in sidecars. Bump this constant and CHANGELOG.md
# together at release time.
TOOL_VERSION = "0.33.0" # setup + notes, record type, histogram PVS and mic from the file; gates the backfill regen
TOOL_VERSION = "0.34.0" # file-only decode groups A-D, histogram times (#51); gates the backfill regen
try:
# Best-effort: prefer the installed metadata when it's NEWER than the
@@ -793,6 +794,45 @@ def _peaks_from_samples(samples: dict[str, list[int]],
)
# Blastware's g for peak acceleration, fitted: every printed acceleration in
# DL2 bounds it, and together they leave [386.2236, 386.2240] in/s^2 -- 19,475 /
# 19,479 values fit (the other 4: one odd file, O117I1NK.R70W, and one sample
# mismatch). That is 9.81 m/s^2 (386.2205) plus an offset not explained, as
# with the mic's fitted dB offset; 9.81 gives 19,423, the standard 9.80665 gives
# 17,806 (2026-11-04).
_ACCEL_IPS2_PER_G = 386.2238
def _waveform_peak_detail(pv: PeakValues, samples: dict[str, list[int]], geo_fs_ins: float,
sample_rate: int, pretrig: int) -> None:
"""A waveform's time of peak per channel, the vector sum's time and each
geophone's peak acceleration, on `pv`. Measured on 400 DL2 waveforms
(2026-11-04):
* time of peak = (first peak sample - pre-trigger samples) / sample rate,
1,197 / 1,197; the vector-sum time is the same on sqrt(T^2 + V^2 + L^2),
398 / 399
* peak acceleration = the largest |v[i+1] - v[i]| x sample rate / g,
with Blastware's fitted g -- the manuals: "subtracts two velocity
readings and divides the result by the elapsed time between them"."""
scale = geo_fs_ins / _GEO_INT16_FS
geo = {}
for ch in ("Tran", "Vert", "Long", "MicL"):
c = samples.get(ch) or []
if not c:
continue
i = max(range(len(c)), key=lambda k: abs(c[k]))
setattr(pv, f"{ch.lower()}_time_of_peak", (i - pretrig) / sample_rate)
if ch != "MicL":
geo[ch] = c
step = max((abs(c[k + 1] - c[k]) for k in range(len(c) - 1)), default=0)
setattr(pv, f"{ch.lower()}_peak_accel_g", step * scale * sample_rate / _ACCEL_IPS2_PER_G)
if len(geo) == 3:
n = min(len(c) for c in geo.values())
t, v, l = geo["Tran"], geo["Vert"], geo["Long"]
j = max(range(n), key=lambda k: t[k] * t[k] + v[k] * v[k] + l[k] * l[k])
pv.pvs_time = (j - pretrig) / sample_rate
# STRT[18], the record-type byte (#41): 0x46 on every one of DL2's 6,577
# waveform files and 0x0A on every one of its 63,535 histograms (measured
# 2026-10-29). Manual / Event / Combo never occur there, so their bytes are
@@ -862,6 +902,7 @@ _RECTIME_OFFSET_BEFORE_MARKER = 30
# 2026-10-29). Offsets are from the first byte of the name.
_SETUP_NAME_RE = re.compile(rb"\x1c\x08([\x20-\x7e]{1,40})\x00")
_SAMPLE_RATE_BEFORE_NAME = 42 # uint16 BE, samples per second
_INTERVAL_BEFORE_NAME = 40 # uint16 BE, histogram interval in seconds (2 / 5 / 15 / 60 / 300)
_PRETRIG_BEFORE_NAME = 36 # float32 BE, seconds, negative (-0.25, -0.0625 ...)
_RECTIME_BEFORE_NAME = 30 # float32 BE, seconds (the marker's offset above)
_SAMPLE_RATES = (1024, 2048, 4096)
@@ -895,17 +936,22 @@ def _ts8(b: bytes) -> Optional[datetime.datetime]:
def _embedded_event_record(
raw: bytes, end: int, start: Optional[datetime.datetime],
stop: Optional[datetime.datetime], record_time: Optional[float],
) -> tuple[Optional[datetime.datetime], str]:
"""The trigger time from the instrument's embedded event record, or (None, why).
) -> tuple[Optional[datetime.datetime], str, Optional[int]]:
"""The trigger time and trigger source from the instrument's embedded event
record, or (None, why, None).
Every `fe 80` before `end` (the footer) is a candidate. One counts only if
its lead bytes match, both its times are well formed, the footer's session
start <= trigger <= its stop, its stop is the footer's stop or a second
before it, and its length agrees with the record time. Exactly one may
pass: none, or more than one, is reported rather than guessed between.
The two bytes between the lead and `fe 80` are the trigger source, a uint16
BE bitmask: 0x01 Tran, 0x02 Vert, 0x04 Long, 0x08 MicL, 0x200 Manual --
Blastware's Trigger on 6,493 / 6,493 DL2 waveforms (2026-11-03).
"""
if start is None or stop is None:
return None, "the footer has no start and stop to check one against"
return None, "the footer has no start and stop to check one against", None
found, rejected = [], 0
i = raw.find(_EVENT_RECORD_MARKER, 6)
while 0 <= i and i + 18 <= end:
@@ -921,15 +967,62 @@ def _embedded_event_record(
<= _EVENT_RECORD_SLACK_S[1])
)
if valid:
found.append(trig)
found.append((trig, int.from_bytes(raw[i - 2:i], "big")))
else:
rejected += 1
i = raw.find(_EVENT_RECORD_MARKER, i + 1)
if len(found) == 1:
return found[0], ""
return found[0][0], "", found[0][1]
if found:
return None, f"{len(found)} candidates validate"
return None, (f"{rejected} candidate(s), none valid" if rejected else "no candidate")
return None, f"{len(found)} candidates validate", None
return None, (f"{rejected} candidate(s), none valid" if rejected else "no candidate"), None
# A histogram's event record: the same lead, the source 0x0400, marker fe f5,
# then its start and stop -- Blastware's Histogram Start / Stop on 63,490 /
# 63,490 DL2 histograms. On all 63,500 its start is 0 or 1 s after the footer's
# start and its stop 0 or 1 s before the footer's stop (2026-11-03).
_HISTOGRAM_RECORD_MARKER = b"\xfe\xf5"
_HISTOGRAM_RECORD_SOURCE = b"\x04\x00"
def interval_times(start: datetime.datetime, interval_sec: int,
stop: Optional[datetime.datetime], n: int) -> list[datetime.datetime]:
"""Each histogram interval's time as Blastware prints it: the interval's
end, start + (i + 1) x interval, capped at the stop. 2,308,524 / 2,308,524
DL2 rows; and an event's peak date and time are its interval's (2026-11-03)."""
out = []
for i in range(n):
t = start + datetime.timedelta(seconds=interval_sec * (i + 1))
out.append(min(t, stop) if stop is not None else t)
return out
def _histogram_event_record(
raw: bytes, end: int, start: Optional[datetime.datetime],
stop: Optional[datetime.datetime],
) -> tuple[Optional[datetime.datetime], Optional[datetime.datetime], str]:
"""(start, stop) from a histogram's own event record, or (None, None, why).
Exactly one record may validate against the footer's start and stop."""
if start is None or stop is None:
return None, None, "the footer has no start and stop to check one against"
found, rejected = [], 0
i = raw.find(_HISTOGRAM_RECORD_MARKER, 6)
while 0 <= i and i + 18 <= end:
a, b = _ts8(raw[i + 2:i + 10]), _ts8(raw[i + 10:i + 18])
if (raw[i - 6:i - 2] == _EVENT_RECORD_LEAD and raw[i - 2:i] == _HISTOGRAM_RECORD_SOURCE
and a is not None and b is not None and a <= b
and 0 <= (a - start).total_seconds() <= 1
and 0 <= (stop - b).total_seconds() <= 1):
found.append((a, b))
elif raw[i - 6:i - 2] == _EVENT_RECORD_LEAD:
rejected += 1
i = raw.find(_HISTOGRAM_RECORD_MARKER, i + 1)
if len(found) == 1:
return found[0][0], found[0][1], ""
if found:
return None, None, f"{len(found)} candidates validate"
return None, None, (f"{rejected} candidate(s), none valid" if rejected else "no candidate")
def _parse_record_time_seconds(raw: bytes) -> Optional[float]:
@@ -1047,6 +1140,83 @@ def _setup_geo_range(raw: bytes) -> tuple[Optional[int], Optional[str]]:
return None, f"geophone range not read: channel range bytes {found}"
# The identity block before the setup: what the live read gets from SUB FE
# (DeviceInfo). Offsets back from k, the setup name; matched against every DL2
# report 2026-11-03 -- serial, version and calibration 69,983 / 69,983, the
# battery 69,729 plus 254 that Blastware rounds half up (6.25 -> "6.3 Volts").
_SERIAL_BEFORE_NAME = 202 # ASCII, NUL-terminated
_BATTERY_BEFORE_NAME = 190 # uint16 BE, hundredths of a volt
_FIRMWARE_MINOR_BEFORE_NAME = 193 # 0x11 = 17 for S338.17, as SUB EA
_FIRMWARE_BEFORE_NAME = 147 # "S338.17"
_DSP_BEFORE_NAME = 138 # "10.72"
_CALIBRATION_BEFORE_NAME = 132 # dd mm yyyy (BE)
_CALIBRATED_BY_BEFORE_NAME = 128 # "Instantel"
_MANUFACTURER_BEFORE_NAME = 94 # "Instantel"
_MODEL_BEFORE_NAME = 72 # "MiniMate Plus" / "BlastMate III"
def _cstr(raw: bytes, i: int, limit: int = 40) -> Optional[str]:
if i < 0:
return None
j = raw.find(b"\x00", i, i + limit)
s = raw[i:j if j >= 0 else i + limit].decode("ascii", errors="replace").strip()
return s or None
def _setup_identity(raw: bytes, k: int) -> tuple[Optional[DeviceInfo], Optional[float]]:
"""(the unit's identity, the battery in volts) from the block before the
setup name at k."""
if k < _SERIAL_BEFORE_NAME:
return None, None
serial = _cstr(raw, k - _SERIAL_BEFORE_NAME, 16)
if not serial:
return None, None
c = k - _CALIBRATION_BEFORE_NAME
try:
cal = datetime.date(int.from_bytes(raw[c + 2:c + 4], "big"), raw[c + 1], raw[c])
except ValueError:
cal = None
info = DeviceInfo(
serial=serial,
firmware_minor=raw[k - _FIRMWARE_MINOR_BEFORE_NAME],
firmware_version=_cstr(raw, k - _FIRMWARE_BEFORE_NAME, 9),
dsp_version=_cstr(raw, k - _DSP_BEFORE_NAME, 6),
manufacturer=_cstr(raw, k - _MANUFACTURER_BEFORE_NAME),
model=_cstr(raw, k - _MODEL_BEFORE_NAME),
calibration_date=cal,
calibrated_by=_cstr(raw, k - _CALIBRATED_BY_BEFORE_NAME, 32),
)
b = k - _BATTERY_BEFORE_NAME
return info, int.from_bytes(raw[b:b + 2], "big") / 100
# Trigger settings, in Series IV's 0x1A layout again: the trigger-source bitmask
# at k - 19 ([29]: 0x07 geophones, 0x08 mic), the stop mode at k - 31 ([17],
# 0 = Fixed), and each channel block's trigger level, a float32 at label + 30 --
# in/s for a geophone, psi for the mic. The mic block's type code at label + 4
# is Series IV's (2 = linear). Against every DL2 waveform (2026-11-03): the geo
# level 6,447 / 6,447, the mic level 4,403 / 4,403, and Blastware prints a level
# exactly when its channel is a trigger source and the event was not Manual.
_TRIGGER_SOURCES_BEFORE_NAME = 19
_STOP_MODE_BEFORE_NAME = 31
_TRIGGER_LEVEL_AFTER_LABEL = 30
_MIC_TYPE_AFTER_LABEL = 4
def _setup_trigger(raw: bytes, k: int) -> dict:
out = {"trigger_sources": raw[k - _TRIGGER_SOURCES_BEFORE_NAME],
"record_stop_mode": raw[k - _STOP_MODE_BEFORE_NAME]}
t = raw.find(b"\x00\x00\x01Tran", k, k + _CHANNEL_BLOCK_SPAN)
if t >= 0:
p = t + 3 + _TRIGGER_LEVEL_AFTER_LABEL
out["trigger_level_geo"] = struct.unpack_from(">f", raw, p)[0]
m = raw.find(b"MicL", k, k + _CHANNEL_BLOCK_SPAN)
if m >= 0:
out["trigger_level_mic_psi"] = struct.unpack_from(">f", raw, m + _TRIGGER_LEVEL_AFTER_LABEL)[0]
out["mic_type"] = int.from_bytes(raw[m + _MIC_TYPE_AFTER_LABEL:m + _MIC_TYPE_AFTER_LABEL + 4], "big")
return out
def read_blastware_file(path: Union[str, Path], *, name: Optional[str] = None) -> Event:
"""Parse a Blastware event file into an Event: `decode_blastware_bytes` on its
bytes, `name` defaulting to the file's own (see there -- never a time source)."""
@@ -1195,8 +1365,10 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
problems = []
if record_type is None:
problems.append(f"unknown record type byte 0x{type_byte:02x} at STRT[18]")
hist_records = None
if record_type == "Histogram":
decoded = decode_histogram_body(body)
hist_records = decode_histogram_body_full(body)
decoded = channels_from_records(hist_records)
is_waveform_body = False
elif record_type == "Waveform":
decoded = decode_waveform_v2(body)
@@ -1205,7 +1377,8 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
decoded = decode_waveform_v2(body)
is_waveform_body = decoded is not None
if decoded is None:
decoded = decode_histogram_body(body)
hist_records = decode_histogram_body_full(body)
decoded = channels_from_records(hist_records)
if decoded is None:
log.warning(
"%s: body codec failed to decode (body starts %s) — "
@@ -1236,6 +1409,11 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
ev.geo_range, range_problem = _setup_geo_range(raw)
if range_problem:
ev.decode_problems.append(range_problem + "; peaks assume the Normal range")
k = _setup_name_at(raw)
if k is not None:
ev.device_info, ev.battery_volts = _setup_identity(raw, k)
for attr, value in _setup_trigger(raw, k).items():
setattr(ev, attr, value)
if is_waveform_body:
ev.rectime_seconds = _setup_record_time(raw)
ev.total_samples = len(samples["Tran"]) or None
@@ -1266,17 +1444,19 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
# embedded in the 5A stream (_embedded_event_record), so a waveform takes
# it from there. Without a validated one the estimate stands, reported as a
# decode problem -- never a filename's time, which is only a cross-check.
# Histograms stay on ts1 although it runs a second early on 97% (their
# record, marker fe f5, holds the exact start): in Blastware's timing a
# waveform and its histogram share a second 209 times in prod's store, and
# events is unique on (serial, timestamp) -- #51.
# A histogram's footer start runs a second early on 97%. Its own event
# record (marker fe f5) holds Blastware's exact start and stop, so it takes
# them from there (#51); events are keyed unit + time + type, so a waveform
# and its histogram may share a second.
# ⚠ RETRACTED 2026-11-03: "histograms stay on ts1" -- that held only while
# events were unique on (serial, timestamp).
if is_waveform_body and ts2 is not None:
_stop = datetime.datetime(ts2.year, ts2.month, ts2.day,
ts2.hour, ts2.minute, ts2.second)
_rt = _parse_record_time_seconds(raw)
_start = (datetime.datetime(ts1.year, ts1.month, ts1.day, ts1.hour, ts1.minute, ts1.second)
if ts1 is not None else None)
_trig, _why = _embedded_event_record(raw, footer_pos, _start, _stop, _rt)
_trig, _why, ev.triggered_by = _embedded_event_record(raw, footer_pos, _start, _stop, _rt)
if _trig is not None:
ev.timestamp_source = "event_record"
else:
@@ -1298,13 +1478,25 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
hour=_trig.hour, minute=_trig.minute, second=_trig.second,
)
elif ts1 is not None:
_start, _hstop, _why = (_histogram_event_record(raw, footer_pos, ts1, ts2)
if record_type == "Histogram" else (None, None, ""))
if _start is not None:
ev.timestamp_source = "event_record"
ev.stop_time = _hstop
else:
_start = ts1
ev.timestamp_source = "footer"
if record_type == "Histogram":
_problem = (f"no validated histogram event record ({_why}); the start is the "
"footer's, a second early on 97% of measured files")
ev.decode_problems.append(_problem)
log.warning("%s: %s", label, _problem)
ev.timestamp = Timestamp(
raw=footer[2:10],
flag=0x10,
year=ts1.year, unknown_byte=0, month=ts1.month, day=ts1.day,
hour=ts1.hour, minute=ts1.minute, second=ts1.second,
year=_start.year, unknown_byte=0, month=_start.month, day=_start.day,
hour=_start.hour, minute=_start.minute, second=_start.second,
)
ev.timestamp_source = "footer"
ev.project_info = _setup_notes(raw)
ev.raw_samples = samples
@@ -1327,14 +1519,32 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
# The geophone full scale is the file's range; Normal when it wasn't read.
geo_fs = _GEO_FS_BY_RANGE.get(ev.geo_range, _GEO_NORMAL_FS_INS)
ev.peak_values = _peaks_from_samples(samples, geo_fs) if has_samples else None
if not is_waveform_body and ev.peak_values is not None:
# A histogram stores each interval's vector sum (squared); the event's
# is the largest. Combining the channel peaks instead read high on 86%
# of DL2's histograms -- they can come from different moments.
pvs = interval_pvs(body)
if pvs:
ev.peak_values.peak_vector_sum = (
max(pvs) * _HIST_GEO_COUNTS_PER_UNIT * geo_fs / _GEO_INT16_FS)
if (is_waveform_body and ev.peak_values is not None and ev.sample_rate
and ev.pretrig_samples is not None):
_waveform_peak_detail(ev.peak_values, samples, geo_fs, ev.sample_rate, ev.pretrig_samples)
if ev.stop_time is None: # a histogram's record stop, else the footer's
ev.stop_time = ts2
if hist_records:
# A histogram stores each interval's vector sum (squared), and each
# channel's half-period: Blastware's per-interval Geo PVS (771,354 /
# 771,354 DL2 cells) and frequency, (sample rate / 2) / half-period.
unit_ins = _HIST_GEO_COUNTS_PER_UNIT * geo_fs / _GEO_INT16_FS
ev.interval_pvs = [math.sqrt(r["pvs_sq"]) * unit_ins for r in hist_records]
ev.interval_half_periods = {
ch: [r[key] for r in hist_records if r[key] is not None]
for ch, key in (("Tran", "t_halfp"), ("Vert", "v_halfp"),
("Long", "l_halfp"), ("MicL", "m_halfp"))}
if not ev.interval_half_periods["MicL"]:
del ev.interval_half_periods["MicL"]
k = _setup_name_at(raw)
if k is not None and k >= _INTERVAL_BEFORE_NAME:
ev.histogram_interval_sec = int.from_bytes(
raw[k - _INTERVAL_BEFORE_NAME:k - _INTERVAL_BEFORE_NAME + 2], "big") or None
if not is_waveform_body and ev.peak_values is not None and ev.interval_pvs:
# The event's vector sum is the largest interval's. Combining the
# channel peaks instead read high on 86% of DL2's histograms -- they
# can come from different moments.
ev.peak_values.peak_vector_sum = max(ev.interval_pvs)
ev._a5_frames = None # not recoverable from BW file
return ev
+18 -11
View File
@@ -156,10 +156,11 @@ _BLOCK_MARKER = 10
# 16-count-unit output (1 unit = 0.005 in/s = 16 ADC counts).
_GEO_LSB_INS = 0.005
# Frequency formula: freq_Hz = _FREQ_NUMERATOR / half_period_samples.
# Empirically determined to be 512 (= sample_rate / 2, where sample rate
# is 1024 sps for the standard MiniMate Plus configuration).
_FREQ_NUMERATOR = 512
# Frequency formula: freq_Hz = (sample_rate / 2) / half_period_samples.
# ⚠ RETRACTED 2026-11-03 (#50): "a fixed numerator of 512". 512 is sample_rate
# / 2 at 1024 sps only; at 2048 sps it halved every frequency. Measured on DL2:
# 527,915 / 527,915 cells at 1024 sps and 1,725 / 1,725 at 2048.
_FREQ_NUMERATOR = 512 # sample_rate / 2 at the default 1024 sps
def _is_data_block(block: bytes) -> bool:
@@ -300,7 +301,11 @@ def decode_histogram_body(body: bytes) -> Optional[dict]:
to get 1-count ADC values, then ``count / 32767 * 10.0`` for in/s)
- Mic channel: use ``waveform_codec.mic_count_to_db(count)``
"""
records = _walk_auto(body)
return channels_from_records(_walk_auto(body))
def channels_from_records(records: Optional[List[dict]]) -> Optional[dict]:
"""``decode_histogram_body``'s per-channel peaks, from records already walked."""
if not records:
return None
return {
@@ -338,17 +343,19 @@ def interval_pvs(body: bytes) -> Optional[List[float]]:
return [math.sqrt(r["pvs_sq"]) for r in records] if records else None
def half_period_to_hz(halfp: int) -> Optional[float]:
"""Convert a half-period in samples to frequency in Hz.
def half_period_to_hz(halfp: int, sample_rate: int = 1024) -> Optional[float]:
"""Convert a half-period in samples to frequency in Hz:
``(sample_rate / 2) / halfp``.
Returns ``None`` for half-period ≤ 5 — the device emits values in
that range when the measured zero-crossing rate exceeds 100 Hz
(the BW display reports `>100 Hz` for such cases). Callers can
treat ``None`` as the `>100 Hz` sentinel.
that range when the measured zero-crossing rate exceeds 100 Hz at
1024 sps (the BW display reports `>100`, `>200` at 2048 sps). Callers
can treat ``None`` as that sentinel. A half-period of 0 is Blastware's
"N/A"; it also returns None.
"""
if halfp <= 5:
return None
return _FREQ_NUMERATOR / halfp
return (sample_rate / 2) / halfp
def geo_count_to_ins(count: int) -> float:
+27
View File
@@ -300,6 +300,10 @@ class DeviceInfo:
# ── From SUB 08 (EVENT_INDEX_RESPONSE) ────────────────────────────────────
event_count: Optional[int] = None # stored event count from F7 response 🔶
# ── From a Blastware event file's identity block (2026-11-03) ─────────────
calibration_date: Optional[datetime.date] = None # e.g. 2019-02-20 ✅
calibrated_by: Optional[str] = None # e.g. "Instantel" ✅
def __str__(self) -> str:
fw = self.firmware_version or f"?.{self.firmware_minor}"
mdl = self.model or "MiniMate Plus"
@@ -360,6 +364,15 @@ class PeakValues:
vert_zc_above_range: bool = False
long_zc_above_range: bool = False
mic_zc_above_range: bool = False
# A waveform's peak detail, from its samples (2026-11-04); None for a histogram.
tran_time_of_peak: Optional[float] = None # s from the trigger; negative = pre-trigger
vert_time_of_peak: Optional[float] = None
long_time_of_peak: Optional[float] = None
micl_time_of_peak: Optional[float] = None
pvs_time: Optional[float] = None # s from the trigger, of the vector-sum peak
tran_peak_accel_g: Optional[float] = None
vert_peak_accel_g: Optional[float] = None
long_peak_accel_g: Optional[float] = None
# ── Project / operator metadata ───────────────────────────────────────────────
@@ -548,6 +561,20 @@ class Event:
# Geophone range from the recording setup, as ComplianceConfig.geo_range:
# 0 Normal (10 in/s full scale), 1 Sensitive (1.25 in/s). None: not read.
geo_range: Optional[int] = None
# From a Blastware event file (2026-11-03); None when not read.
device_info: Optional["DeviceInfo"] = None # the unit, as SUB FE reports it
battery_volts: Optional[float] = None # at the event
triggered_by: Optional[int] = None # 0x01 Tran 0x02 Vert 0x04 Long 0x08 MicL 0x200 Manual
trigger_sources: Optional[int] = None # setup bitmask: 0x07 geophones, 0x08 mic
trigger_level_geo: Optional[float] = None # in/s, as ComplianceConfig.trigger_level_geo
trigger_level_mic_psi: Optional[float] = None
record_stop_mode: Optional[int] = None # 0 = Fixed
mic_type: Optional[int] = None # 2 = Linear Weighting (as Series IV)
stop_time: Optional[datetime.datetime] = None # the footer's stop
# A histogram's per-interval detail (2026-11-03); None for a waveform.
histogram_interval_sec: Optional[int] = None # as ComplianceConfig.histogram_interval_sec
interval_half_periods: Optional[dict] = None # channel -> half-period per interval, samples
interval_pvs: Optional[list] = None # each interval's vector sum, in/s
# Sensor self-check traces keyed by channel label — the short diagnostic
# waveforms the unit records when it pulses each sensor before monitoring
+80 -12
View File
@@ -142,9 +142,14 @@ _WRITE_TAIL = {SUB_EVENT_INDEX_WRITE: b"\x02\x00", SUB_TRIGGER_CONFIG_WRITE: b"\
SUB_CALL_HOME_WRITE: b"\x00\x00"}
def write_image(sub: int, data: bytes) -> bytes:
def write_image(sub: int, data: bytes, *, escaped: bool = True) -> bytes:
"""The whole block a write sends: `data` unescaped, N + 2 bytes.
`escaped=False`: `data` is already logical (every block read since phase 5 --
read_event_index, read_compliance_content, read_trigger_config,
read_waveform_data_raw -- returns unescaped bytes), so it is NOT unescaped
again: a logical `10 02` (job number 4098) would otherwise collapse.
A config block starts with its own length N (uint16 BE) and is written as N
bytes plus two -- on every Blastware write on record. `data` may be the
block as a read returned it (N bytes, or N + 2) and may still hold the
@@ -152,7 +157,7 @@ def write_image(sub: int, data: bytes) -> bytes:
Anything else is refused before a byte is sent: a block one byte longer than
its header says is what an edit beside a kept escape byte leaves behind.
"""
image = unescape_reply(bytes(data))
image = unescape_reply(bytes(data)) if escaped else bytes(data)
if len(image) < 2:
raise ValueError(f"write SUB 0x{sub:02X}: {len(image)} bytes is not a whole block")
n = int.from_bytes(image[:2], "big")
@@ -169,6 +174,45 @@ class ImageRefused(ValueError):
"""A write refused before any byte was sent: the image is not a whole block."""
# ── The settings block (SUB 1A), as content ─────────────────────────────────
#
# Measured 2026-11-03 on BE9441's 10-26 recording (12 reads, both Blastware's
# 4 x 512 + 42 pattern and SFM's 1024 + 1024 + 42): unescape each data frame and
# take data[11:]; every frame but the last then starts with one `00` that is not
# content. Dropped, the frames join into 2,090 bytes that start with their own
# length N = 2090 -- Series IV's 0x1A content layout -- and the read after each
# of Blastware's two writes equals the image it had just written.
# tests/test_s3_settings_read.py.
COMPLIANCE_CONTENT_LEN = 2090
# SFM's 1A read: (offset = the content length asked for, page) per data frame.
_COMPLIANCE_READ_STEPS = ((0x0400, 0x00), (0x0400, 0x04), (0x002A, 0x08))
def assemble_compliance_content(frames: "list[bytes]", lengths: "Optional[tuple]" = None) -> bytes:
"""Join a 1A read's data frames (each S3Frame.data, kept escapes and all, in
order) into the logical settings block. Judges nothing: a monitoring unit's
device-info answer assembles too -- `is_compliance_content` tells them apart.
`lengths`: the content each frame was asked for (SFM's read: 1024, 1024, 42).
Each frame then gives exactly that. Measured at the bench 2026-11-04 (BE9441):
when a frame's checksum byte is itself escaped (02 / 03 / 04), the parser keeps
the escape's 0x10 and strips only the byte after it, so the frame arrives one
byte long, ending in a lone 0x10. That one byte is dropped; any other leftover
is kept, and the block then fails is_compliance_content."""
parts = [unescape_reply(bytes(f))[11:] for f in frames]
parts = [p[1:] for p in parts[:-1]] + parts[-1:]
if lengths is not None and len(lengths) == len(parts):
parts = [p[:n] if p[n:] == b"\x10" else p for p, n in zip(parts, lengths)]
return b"".join(parts)
def is_compliance_content(block: bytes) -> bool:
"""Whether `block` is the settings block: 2,090 bytes headed by N = 2090."""
return (len(block) == COMPLIANCE_CONTENT_LEN
and int.from_bytes(block[0:2], "big") == COMPLIANCE_CONTENT_LEN)
def is_call_home_block(raw: bytes) -> bool:
"""Whether a 0x2C reply payload is the call-home block: it starts with its own
length N = 0x7C (00 7C DC on every read on record) and is N (or N + 2) bytes
@@ -589,6 +633,10 @@ class MiniMateProtocol:
data_rsp = self._recv_one(expected_sub=rsp_sub)
raw = unescape_reply(data_rsp.data)[11:] # unescaped, as read_event_index
# An escaped checksum byte leaves its 0x10 behind (bench 2026-11-04; see
# assemble_compliance_content): one stray byte beyond what was asked is dropped.
if len(raw) == length + 1 and raw[-1:] == b"\x10":
raw = raw[:-1]
log.debug("read_waveform_data_raw: got %d bytes", len(raw))
return raw
@@ -1029,6 +1077,25 @@ class MiniMateProtocol:
return bytes(config)
def read_compliance_content(self) -> bytes:
"""The 1A read as the logical settings block (see assemble_compliance_content).
The same requests as read_compliance_config -- probe, then B / C / D -- but
strict: a data frame that does not arrive raises, and there is no tail
drain, so a short read is never assembled. Returns whatever assembled,
unjudged; a MONITORING unit answers with its device-info block, which
is_compliance_content() rejects.
"""
rsp_sub = _expected_rsp_sub(SUB_COMPLIANCE)
self._send(build_bw_frame(SUB_COMPLIANCE, 0, bytes([0, 0, 0, 0, 0, 0, 0, 0x64, 0, 0])))
self._recv_one(expected_sub=rsp_sub)
frames = []
for offset, page in _COMPLIANCE_READ_STEPS:
self._send(build_bw_frame(SUB_COMPLIANCE, offset,
bytes([0, 0, page, 0, 0, 0, 0, 0x64, 0, 0])))
frames.append(self._recv_one(expected_sub=rsp_sub).data)
return assemble_compliance_content(frames, lengths=tuple(o for o, _ in _COMPLIANCE_READ_STEPS))
# ── Write commands (SUBs 68–83) ───────────────────────────────────────────
def recv_write_ack(
@@ -1086,25 +1153,26 @@ class MiniMateProtocol:
self._send(frame)
return self.recv_write_ack(expected_sub=rsp_sub)
def _write_block(self, sub: int, data: bytes, params: bytes = bytes(10)) -> S3Frame:
def _write_block(self, sub: int, data: bytes, params: bytes = bytes(10), *,
escaped: bool = True) -> S3Frame:
"""Send one config block as a write and return its ack (0xFF - sub)."""
image = write_image(sub, data)
image = write_image(sub, data, escaped=escaped)
frame = build_bw_write_frame(sub, image, params=params)
log.debug("write SUB=0x%02X: %d-byte image", sub, len(image))
self._send(frame)
return self.recv_write_ack(expected_sub=_expected_rsp_sub(sub))
def write_event_index(self, data: bytes) -> S3Frame:
def write_event_index(self, data: bytes, *, escaped: bool = True) -> S3Frame:
"""SUB 68: write the event-index block (as SUB 08 read it). Ack 0x97;
callers follow with write_confirm(SUB_WRITE_CONFIRM_B). See write_image."""
return self._write_block(SUB_EVENT_INDEX_WRITE, data)
return self._write_block(SUB_EVENT_INDEX_WRITE, data, escaped=escaped)
def write_waveform_data(self, data: bytes) -> S3Frame:
def write_waveform_data(self, data: bytes, *, escaped: bool = True) -> S3Frame:
"""SUB 69: write the waveform-data block (as SUB 09 read it). Ack 0x96;
callers follow with write_confirm C then A. See write_image."""
return self._write_block(SUB_WAVEFORM_DATA_WRITE, data)
return self._write_block(SUB_WAVEFORM_DATA_WRITE, data, escaped=escaped)
def write_compliance_config_raw(self, data: bytes) -> None:
def write_compliance_config_raw(self, data: bytes, *, escaped: bool = True) -> None:
"""SUB 71: write the compliance image in addressed chunks, then confirm (72).
Measured: the image is 2,092 bytes (its header N = 2,090, plus 2), sent as
@@ -1115,7 +1183,7 @@ class MiniMateProtocol:
both. (Retracted: "exactly 3 chunks, offset 0x1004, params 00 00 00 10 04"
-- the length 0x0400 and address 0x0400, read with their escape bytes.)
"""
image = write_image(SUB_COMPLIANCE_WRITE, data)
image = write_image(SUB_COMPLIANCE_WRITE, data, escaped=escaped)
rsp_sub = _expected_rsp_sub(SUB_COMPLIANCE_WRITE)
for addr in range(0, len(image), _COMPLIANCE_CHUNK):
params = bytes([0x00, 0x00, (addr >> 8) & 0xFF, addr & 0xFF]) + bytes(6)
@@ -1126,10 +1194,10 @@ class MiniMateProtocol:
self.recv_write_ack(expected_sub=rsp_sub)
self.write_confirm(SUB_WRITE_CONFIRM_A)
def write_trigger_config(self, data: bytes) -> S3Frame:
def write_trigger_config(self, data: bytes, *, escaped: bool = True) -> S3Frame:
"""SUB 82: write the trigger block (as SUB 0x2E read it). Ack 0x7D;
callers follow with write_confirm(SUB_TRIGGER_CONFIRM). See write_image."""
return self._write_block(SUB_TRIGGER_CONFIG_WRITE, data)
return self._write_block(SUB_TRIGGER_CONFIG_WRITE, data, escaped=escaped)
def read_trigger_config(self) -> bytes:
"""SUB 0x2E two-step read: the 26-byte trigger block that SUB 82 writes.
-68
View File
@@ -1,68 +0,0 @@
"""
poc_set_project.py — POC test for set_project_info() against a live MiniMate Plus.
Usage:
python poc_set_project.py [--host IP] [--port PORT]
Default target: BE11529 at 63.43.212.232:9034
"""
import argparse
import logging
import sys
logging.basicConfig(
level=logging.DEBUG,
format="%(asctime)s %(levelname)-7s %(name)s %(message)s",
datefmt="%H:%M:%S",
)
log = logging.getLogger("poc_set_project")
from minimateplus import MiniMateClient
from minimateplus.transport import TcpTransport
DEFAULT_HOST = "63.43.212.232"
DEFAULT_PORT = 9034
def main() -> None:
ap = argparse.ArgumentParser(description="POC: write project info to MiniMate Plus")
ap.add_argument("--host", default=DEFAULT_HOST, help="Modem IP address")
ap.add_argument("--port", type=int, default=DEFAULT_PORT, help="TCP port")
ap.add_argument("--project", default="POC Write Test")
ap.add_argument("--client-name", default="Terra-Mechanics Inc.")
ap.add_argument("--operator", default="B. Harrison")
ap.add_argument("--seis-loc", default="Lab Bench - POC")
ap.add_argument("--notes", default="set_project_info POC 2026-04-07")
args = ap.parse_args()
log.info("Connecting to %s:%d", args.host, args.port)
transport = TcpTransport(args.host, port=args.port)
with MiniMateClient(transport=transport, timeout=60.0) as client:
log.info("Performing POLL handshake + identity read …")
info = client.connect()
log.info("Connected: serial=%s firmware=%s", info.serial, info.firmware_version)
log.info("Calling set_project_info() …")
client.set_project_info(
project=args.project,
client_name=args.client_name,
operator=args.operator,
seis_loc=args.seis_loc,
notes=args.notes,
)
log.info("set_project_info() returned — write sequence complete")
log.info("Done. Reconnect Blastware to verify the fields were written.")
if __name__ == "__main__":
try:
main()
except KeyboardInterrupt:
sys.exit(0)
except Exception as exc:
log.exception("Fatal: %s", exc)
sys.exit(1)
+1 -1
View File
@@ -4,7 +4,7 @@ build-backend = "setuptools.build_meta"
[project]
name = "seismo-relay"
version = "0.33.0"
version = "0.34.0"
description = "Python client and REST server for MiniMate Plus seismographs"
requires-python = ">=3.10"
dependencies = [
+5 -4
View File
@@ -73,7 +73,7 @@ def main(argv: list[str] | None = None) -> int:
conn.row_factory = sqlite3.Row
rows = list(conn.execute(
"SELECT id, serial, timestamp, blastware_filename "
"SELECT id, serial, timestamp, record_type, blastware_filename "
" FROM events "
" WHERE serial = 'UNKNOWN' "
" ORDER BY timestamp",
@@ -98,10 +98,11 @@ def main(argv: list[str] | None = None) -> int:
unresolved += 1
continue
# Check for an existing row at the target (serial, timestamp).
# Check for an existing row at the target key (serial, timestamp,
# record_type -- #51).
existing = conn.execute(
"SELECT id FROM events WHERE serial = ? AND timestamp = ?",
(new_serial, ts),
"SELECT id FROM events WHERE serial = ? AND timestamp = ? AND record_type IS ?",
(new_serial, ts, row["record_type"]),
).fetchone()
action: str
if existing is None:
+77 -22
View File
@@ -36,6 +36,7 @@ from __future__ import annotations
import datetime
import json
import logging
import re
import sqlite3
import uuid
from pathlib import Path
@@ -107,7 +108,7 @@ CREATE TABLE IF NOT EXISTS events (
shape_offset_pre REAL, -- pre-trigger baseline median (in/s)
shape_offset_spread REAL, -- max(pre,mid,end) - min(...) in in/s; small = constant/DC
created_at TEXT NOT NULL DEFAULT (strftime('%Y-%m-%dT%H:%M:%SZ', 'now')),
UNIQUE(serial, timestamp)
UNIQUE(serial, timestamp, record_type) -- unit + time + type (#51); see Migration 3
);
CREATE INDEX IF NOT EXISTS idx_events_serial ON events(serial);
CREATE INDEX IF NOT EXISTS idx_events_timestamp ON events(timestamp);
@@ -194,7 +195,7 @@ class SeismoDb:
row = conn.execute(
"SELECT sql FROM sqlite_master WHERE type='table' AND name='events'"
).fetchone()
if row and "UNIQUE(serial, timestamp)" not in row[0]:
if row and "UNIQUE(serial, timestamp" not in row[0]: # neither key form yet
log.info("_migrate: rebuilding events table — UNIQUE(serial, timestamp)")
conn.executescript("""
ALTER TABLE events RENAME TO events_old;
@@ -348,6 +349,33 @@ class SeismoDb:
""")
log.info("_migrate: monitor_log table rebuilt OK")
# Migration 3 (#51, 2026-11-03): events UNIQUE (serial, timestamp) ->
# (serial, timestamp, record_type). A unit records a waveform and a
# histogram in the same second legitimately -- 209 times in prod's
# 2026-09-30 store once histograms carry Blastware's start -- and the old
# key could hold only one. The table is rebuilt from its own current
# definition with only the key swapped, so every column added by the
# migrations above, every row and every id is kept (Terra-View reads
# rows by id); its indexes are recreated. One transaction.
row = conn.execute(
"SELECT sql FROM sqlite_master WHERE type='table' AND name='events'"
).fetchone()
if row and "UNIQUE(serial, timestamp)" in row[0]:
log.info("_migrate: rebuilding events table — UNIQUE(serial, timestamp, record_type)")
indexes = [r[0] for r in conn.execute(
"SELECT sql FROM sqlite_master WHERE type='index' AND tbl_name='events' "
"AND sql IS NOT NULL")]
table = re.sub(r'^CREATE TABLE\s+("?)events\1', "CREATE TABLE events_rekeyed",
row[0].replace("UNIQUE(serial, timestamp)",
"UNIQUE(serial, timestamp, record_type)", 1))
conn.executescript("BEGIN;\n" + table + ";\n"
"INSERT INTO events_rekeyed SELECT * FROM events;\n"
"DROP TABLE events;\n"
"ALTER TABLE events_rekeyed RENAME TO events;\n"
+ "".join(sql + ";\n" for sql in indexes)
+ "COMMIT;")
log.info("_migrate: events table re-keyed OK (%d indexes recreated)", len(indexes))
@staticmethod
def _iso(dt: Optional[datetime.datetime]) -> Optional[str]:
return dt.isoformat() if dt is not None else None
@@ -507,7 +535,8 @@ class SeismoDb:
device_family: Optional[str] = None,
) -> tuple[int, int]:
"""
Insert triggered events. Silently skips duplicates (serial+timestamp).
Insert triggered events. Silently skips duplicates (serial + timestamp +
record_type: a waveform and a histogram may share a second, #51).
Returns (inserted, skipped).
``waveform_records`` (optional): dict keyed by event waveform_key (hex)
@@ -515,7 +544,7 @@ class SeismoDb:
{"filename": str, "filesize": int, "a5_pickle_filename": str}
For events whose key is in this dict, the matching columns are
populated. If a row with the same (serial, timestamp) already exists
populated. If a row with the same (serial, timestamp, record_type) already exists
(dedup hit), the matching waveform record is upserted onto the
existing row so a re-download via the live endpoint refreshes the
file metadata.
@@ -558,18 +587,27 @@ class SeismoDb:
# No validated event record: the time may be a second off,
# so it is never allowed to move, merge into or duplicate
# a row (_estimate_guard). The file is already stored.
why = self._estimate_guard(conn, serial, rec.get("filename"), ts)
why = self._estimate_guard(conn, serial, rec.get("filename"), ts,
ev.record_type)
if why:
log.warning("insert_events: %s %s: %s", serial,
rec.get("filename") or key, why)
skipped += 1
continue
elif rec.get("filename") and ts and \
self._restamp_by_file(conn, serial, rec["filename"], ts) is False:
self._restamp_by_file(conn, serial, rec["filename"], ts,
ev.record_type) is False:
skipped += 1
continue
try:
if ev.record_type is None and conn.execute(
"SELECT 1 FROM events WHERE serial = ? AND timestamp = ? "
"AND record_type IS NULL", (serial, ts)).fetchone():
# A UNIQUE key treats NULLs as distinct, so an untyped
# event would never collide: it still refreshes the
# untyped row at its second, as under the old key.
raise sqlite3.IntegrityError("untyped event already stored")
conn.execute(
"""
INSERT INTO events
@@ -629,7 +667,7 @@ class SeismoDb:
inserted += 1
except sqlite3.IntegrityError:
skipped += 1
# UPSERT path: a row for this (serial, timestamp) already
# UPSERT path: a row for this (serial, timestamp, record_type) already
# exists. Refresh every device-authoritative field from
# the new data so that a re-import with better data (e.g.
# a watcher re-forward where the previous attempt missed
@@ -682,7 +720,7 @@ class SeismoDb:
shape_offset_axis = COALESCE(?, shape_offset_axis),
shape_offset_pre = COALESCE(?, shape_offset_pre),
shape_offset_spread = COALESCE(?, shape_offset_spread)
WHERE serial = ? AND timestamp = ?
WHERE serial = ? AND timestamp = ? AND record_type IS ?
""",
(
pv.tran if pv else None,
@@ -719,6 +757,7 @@ class SeismoDb:
rec.get("shape_offset_spread") if rec else None,
serial,
ts,
ev.record_type,
),
)
@@ -728,11 +767,11 @@ class SeismoDb:
@staticmethod
def _estimate_guard(conn: sqlite3.Connection, serial: str, filename: Optional[str],
ts: Optional[str]) -> Optional[str]:
ts: Optional[str], record_type: Optional[str] = None) -> Optional[str]:
"""Why an event whose time is only an estimate must not be written, or None.
An estimate (the decoder found no validated event record) may be a
second off, and (serial, timestamp) is the table's key. So it never
second off, and (serial, timestamp, record_type) is the table's key. So it never
moves a row, never lands on another event's row, and never adds a second
row for an event already stored -- each refusal is logged by the caller,
and the event's file and sidecar are already in the store. Its own
@@ -747,8 +786,8 @@ class SeismoDb:
return (f"already stored under {', '.join(str(t) for t in own)}; its estimated "
f"time {ts} does not move or duplicate it")
holder = conn.execute(
"SELECT blastware_filename FROM events WHERE serial = ? AND timestamp = ?",
(serial, ts)).fetchone()
"SELECT blastware_filename FROM events WHERE serial = ? AND timestamp = ? "
"AND record_type IS ?", (serial, ts, record_type)).fetchone()
if holder is not None and (named is None or holder[0] != named):
return (f"its estimated time {ts} is held by {holder[0] or 'another event'}; "
"not merged into it")
@@ -756,8 +795,9 @@ class SeismoDb:
@staticmethod
def _restamp_by_file(conn: sqlite3.Connection, serial: str, filename: str,
ts: str) -> Optional[bool]:
"""Move this file's row to `ts` when it sits under another time.
ts: str, record_type: Optional[str] = None) -> Optional[bool]:
"""Move this file's row to `ts` (and `record_type`) when it sits under
another time or type.
The events table is unique on (serial, timestamp), so an event re-stored
with a corrected time -- every Series-3 waveform after the event-time fix,
@@ -768,6 +808,10 @@ class SeismoDb:
stored as "imported.bw" -- so only a Blastware name is matched. Of
several rows for one file, a reviewed one with a time moves first.
The type moves the same way: before v0.33.0 a row's type came from the
filename, and with the type in the key (#51) a re-import under the file's
own type would otherwise add a second row.
Returns True when the row was moved; None when there was nothing to move
(no row for this file elsewhere, or this file's own row already holds
`ts`), so the caller goes on as before; False when a different stored
@@ -778,18 +822,20 @@ class SeismoDb:
return None
mine = conn.execute(
"SELECT id, timestamp FROM events WHERE serial = ? AND blastware_filename = ? "
"AND (timestamp IS NULL OR timestamp != ?) "
"AND (timestamp IS NULL OR timestamp != ? OR record_type IS NOT ?) "
"ORDER BY COALESCE(false_trigger, 0) DESC, timestamp IS NULL, rowid LIMIT 1",
(serial, filename, ts),
(serial, filename, ts, record_type),
).fetchone()
if mine is None:
return None
holder = conn.execute(
"SELECT id, blastware_filename FROM events WHERE serial = ? AND timestamp = ?",
(serial, ts),
"SELECT id, blastware_filename FROM events WHERE serial = ? AND timestamp = ? "
"AND record_type IS ?",
(serial, ts, record_type),
).fetchone()
if holder is None:
conn.execute("UPDATE events SET timestamp = ? WHERE id = ?", (ts, mine[0]))
conn.execute("UPDATE events SET timestamp = ?, record_type = ? WHERE id = ?",
(ts, record_type, mine[0]))
log.info("insert_events: %s %s moved from %s to %s (corrected event time)",
serial, filename, mine[1], ts)
return True
@@ -808,7 +854,8 @@ class SeismoDb:
).fetchone()
return dict(row) if row else None
def find_event_by_blastware_name(self, serial: str, filename: str) -> Optional[dict]:
def find_event_by_blastware_name(self, serial: str, filename: str,
record_type: Optional[str] = None) -> Optional[dict]:
"""The row stored under `filename`'s Blastware name, or None.
A Blastware name encodes the serial and the event's second
@@ -819,6 +866,10 @@ class SeismoDb:
itself and the letterless form -- not the other letter, since in
Histogram+Continuous a waveform can trigger in the second a histogram
starts. Any other name ("imported.bw") matches nothing.
`record_type`: only a row of that type -- or an untyped one, which may be
this event -- matches (#51: a same-second waveform / histogram twin shares
the letterless name). Compared ignoring case.
"""
if blastware_filename_time(filename) is None:
return None
@@ -828,10 +879,14 @@ class SeismoDb:
else:
forms = (name, name + "W", name + "H")
with self._connect() as conn:
typed, args = "", (serial, *forms)
if record_type is not None:
typed = " AND (record_type IS NULL OR UPPER(record_type) = UPPER(?))"
args = (*args, record_type)
row = conn.execute(
f"SELECT * FROM events WHERE serial = ? AND UPPER(blastware_filename) IN "
f"({', '.join('?' * len(forms))}) ORDER BY rowid LIMIT 1",
(serial, *forms),
f"({', '.join('?' * len(forms))}){typed} ORDER BY rowid LIMIT 1",
args,
).fetchone()
return dict(row) if row else None
+33 -1
View File
@@ -9,7 +9,7 @@ import threading
import time
from typing import Any, Callable, Dict, Optional
from .errors import ConnectFailed, DeviceError, NoAnswer, NotSupported, WrongUnit
from .errors import BadRequest, ConnectFailed, DeviceError, NoAnswer, NotSupported, WrongUnit
from .events import parse_event_id
from .locks import UnitLocks
from .models import (CallHomeState, ChangeResult, DownloadedEvent, EventList, UnitAddress, UnitInfo,
@@ -17,6 +17,7 @@ from .models import (CallHomeState, ChangeResult, DownloadedEvent, EventList, Un
from .s3 import Series3Adapter, default_s3_client_factory
from .s4 import (
Series4Session, default_s4_client_factory, s4_call_home_state, s4_change_call_home, s4_change_monitoring,
s4_change_settings,
s4_download_event, s4_identify, s4_list_events, s4_settings, s4_status,
)
from .series import normalise_serial, series_for_serial
@@ -27,6 +28,9 @@ log = logging.getLogger("sfm.device_access")
# reads, a second apart -- not the start/stop window.
_CALL_HOME_VERIFY_TIMEOUT_S = 3.0
_CALL_HOME_VERIFY_INTERVAL_S = 1.0
# A settings read-back is one block read (seconds over cellular): two tries, a second apart.
_SETTINGS_VERIFY_TIMEOUT_S = 2.0
_SETTINGS_VERIFY_INTERVAL_S = 1.0
class DeviceAccess:
@@ -140,6 +144,34 @@ class DeviceAccess:
lambda c, s: s4_change_call_home(c, s, address=address, **kw),
change=True)
def change_settings(self, address: UnitAddress, serial: str, *, changes: dict,
revision: Optional[str], dry_run: bool = False,
caller: str = "api") -> ChangeResult:
"""Change the unit's settings (spec row 10, phase 5). A dry run is the
preview: old -> new per field and a `revision`. A live change needs that
revision; it is audited, identity-checked, sent once, never retried, and
read back. Refused before any I/O: no changes, a live call without a
revision, no audit log."""
serial = normalise_serial(serial)
series_for_serial(serial) # BadRequest (422) before anything else
if not isinstance(changes, dict) or not changes:
raise BadRequest("no settings to change -- nothing sent")
if not dry_run and not revision:
raise BadRequest("preview first: a live change needs the revision from its preview "
"-- nothing sent")
if not dry_run and self._audit is None:
raise NotSupported("no audit log is configured -- SFM refuses to change a unit "
"without one (nothing sent)")
kw = dict(changes=changes, revision=revision, dry_run=dry_run, audit=self._audit,
caller=caller, sleep=self._sleep,
verify_timeout_s=_SETTINGS_VERIFY_TIMEOUT_S,
verify_interval_s=_SETTINGS_VERIFY_INTERVAL_S)
return self._dispatch(
address, serial,
lambda a, s: self._s3.change_settings(a, s, **kw),
lambda c, s: s4_change_settings(c, s, address=address, **kw),
change=True)
def held_serial(self, address: UnitAddress) -> Optional[str]:
"""Serial of the OPEN held Series-4 line at this address, else None. No I/O."""
with self._sessions_guard:
+6
View File
@@ -63,6 +63,12 @@ def call_home_change(enabled: bool) -> ChangeKind:
else ChangeKind("disable call-home", "disabled", "disabled"))
def settings_change() -> ChangeKind:
"""A settings change (phase 5): its "state" is a read-back verdict --
"as asked" (the unit holds what was written), "unchanged", or "differs"."""
return ChangeKind("change settings", "as asked", "applied")
def _take_snapshot(snapshot: Optional[Callable[[], Dict[str, Any]]]) -> Optional[Dict[str, Any]]:
"""The caller's record of what the unit holds after the change -- for the
result and the audit row only. It never decides the outcome."""
+12
View File
@@ -88,6 +88,18 @@ class EventNotFound(DeviceError):
http_status = 404
class SettingsChanged(DeviceError):
"""The unit's settings changed since the preview the request names (a keypad
edit, another program, or a preview of another unit). Nothing was sent."""
http_status = 409
class ChangeRefused(DeviceError):
"""A change SFM will not send to this unit, and why -- its factory setup, a
schedule that would undo it, a block SFM has not seen. Nothing was sent."""
http_status = 409
class StaleEvent(DeviceError):
"""The event at that key is not the one listed -- the unit was erased, or
its memory wrapped, since the list was read."""
+141 -22
View File
@@ -11,15 +11,23 @@ from minimateplus import MiniMateClient
from minimateplus.blastware_file import blastware_file_bytes, blastware_filename, with_type_letter
from minimateplus.event_file_io import _GEO_INT16_FS
from minimateplus.framing import build_bw_write_frame, unescape_reply
from micromate.setup_block import decode_setup
from micromate.setup_fields import (
SettingsValueError, changes_bytes, check_changes, editable_fields, encode_setup, field_rows,
field_values, settings_state,
)
from micromate.setup_fields import revision as settings_revision
from minimateplus.protocol import (
SUB_CALL_HOME_CONFIRM, SUB_CALL_HOME_WRITE, SUB_START_MONITORING, SUB_STOP_MONITORING,
ImageRefused, call_home_enabled, call_home_image, is_call_home_block, write_image,
SUB_CALL_HOME_CONFIRM, SUB_CALL_HOME_WRITE, SUB_COMPLIANCE_WRITE, SUB_EVENT_INDEX_WRITE,
SUB_START_MONITORING, SUB_STOP_MONITORING, SUB_TRIGGER_CONFIG_WRITE, SUB_WAVEFORM_DATA_WRITE,
ImageRefused, call_home_enabled, call_home_image, is_call_home_block, is_compliance_content,
write_image,
)
from minimateplus.transport import TcpTransport
from .errors import (DeviceError, EventNotFound, MalformedReply, NoAnswer, NotSupported, StaleEvent,
UnitStateUnknown, WrongUnit, translate)
from .change import call_home_change, monitoring_change, run_change
from .errors import (BadRequest, ChangeRefused, DeviceError, EventNotFound, MalformedReply, NoAnswer, NotSupported,
SettingsChanged, StaleEvent, UnitStateUnknown, WrongUnit, translate)
from .change import call_home_change, monitoring_change, run_change, settings_change
from .events import iso_of, make_event_id, stamp_of
from .models import (CallHomeState, ChangeResult, DownloadedEvent, EventList, EventRef, UnitAddress,
UnitInfo, UnitSettings, UnitStatus)
@@ -49,6 +57,25 @@ S3_CALL_HOME_WHILE_MONITORING = ("did not return its call-home settings -- a Min
# The 0x1C flag byte (section[1]): the only values ever measured. 0x10 is
# BE11529 monitoring (2026-04-08); 0x0B is BE9441 recording a histogram,
# confirmed at the unit (2026-10-26). Anything else is refused for a change.
# Measured 2026-11-03 (BE9441's 10-26 recording, 5 / 5 reads): while monitoring, a
# MiniMate answers the 1A settings read with its device-info block.
S3_SETTINGS_WHILE_MONITORING = ("did not return its settings -- a MiniMate answers this way "
"while monitoring; stop monitoring first (a stop makes it call in "
"if call-home is on)")
# Blastware's settings write, in its order (push_config_raw): event index, the
# settings block in addressed chunks, trigger, waveform data, with their confirms.
_S3_SETTINGS_STEPS = ((0x68, "event index (as read)"), (0x73, "confirm B"),
(0x71, "settings block"), (0x72, "confirm A"),
(0x82, "trigger block (as read)"), (0x83, "trigger confirm"),
(0x69, "waveform data (as read)"), (0x74, "confirm C"), (0x72, "confirm A"))
_S3_TAIL_WARNING = ("the two bytes after the settings block go out as 00 00 (Blastware sends "
"its own constant; the unit took it at the bench 2026-11-04)")
# Measured at the bench 2026-11-04 (BE9441): a write sent while the setup menu was open
# was acknowledged and read back, then lost when the operator pressed Cancel or Save --
# the menu writes its own copy of the whole block back.
_S3_MENU_WARNING = ("if someone is in this unit's setup menu, this change is lost when they "
"leave it (Cancel or Save writes the menu's copy back)")
S3_RUN_STATES = {0x00: "idle", 0x10: "monitoring", 0x0B: "monitoring"}
@@ -435,29 +462,121 @@ class Series3Adapter:
is_refusal=lambda e: isinstance(e, ImageRefused))
return self._run(address, op, retry=False)
def change_settings(self, address: UnitAddress, serial: str, *, changes: dict,
revision: Optional[str], dry_run: bool, audit: Any, caller: str,
sleep: Callable[[float], None], verify_timeout_s: float,
verify_interval_s: float) -> ChangeResult:
"""Series-3 pieces for the shared core (phase 5): read the four settings
blocks, patch the settings block's fields (micromate.setup_fields), send
Blastware's sequence through push_config_raw with the other three blocks
as read, re-read the settings. One attempt, never retried.
Refused before anything is sent: a monitoring unit (it answers 1A with its
device-info block); a value the unit does not allow (BadRequest); a live
call whose `revision` is not this read's (SettingsChanged)."""
def op(client: Any) -> ChangeResult:
st: dict = {}
reads: list = []
def read_serial() -> str:
return client.connect().serial or "" # a fresh connection: the 0x15 read
def read_state() -> str:
client.wake(attempt_s=S3_WAKE_ATTEMPT_S, deadline_s=S3_WAKE_DEADLINE_S)
if st:
now = client.read_compliance_content()
if not is_compliance_content(now):
raise MalformedReply("the read-back did not return the settings block")
reads.append(now)
return settings_state(st["setup"], st["image"], now, series=3)
blocks = client.read_settings_blocks()
setup = blocks["compliance"]
if not is_compliance_content(setup):
raise UnitStateUnknown(f"{serial} {S3_SETTINGS_WHILE_MONITORING} -- nothing sent")
try:
normal = check_changes(setup, 3, changes)
except SettingsValueError as exc:
raise BadRequest(f"{exc} -- nothing sent") from exc
# What the preview showed: the settings block and the changes. The other
# three blocks are re-read here and sent back as read (the trigger block's
# byte 5 "differs by unit and session", #46).
rev = settings_revision([setup, changes_bytes(normal)])
if not dry_run and revision != rev:
raise SettingsChanged(f"{serial}'s settings, or the changes asked for, are not "
"the ones previewed -- preview again; nothing sent")
image = encode_setup(setup, 3, normal)
blocked = []
for sub, block in ((SUB_EVENT_INDEX_WRITE, blocks["event_index"]),
(SUB_COMPLIANCE_WRITE, image),
(SUB_TRIGGER_CONFIG_WRITE, blocks["trigger"]),
(SUB_WAVEFORM_DATA_WRITE, blocks["waveform"])):
try:
write_image(sub, block, escaped=False) # push_config_raw's own check
except ValueError as exc:
blocked.append(f"this unit's {exc} -- SFM has not seen a block like it")
st.update(blocks=blocks, setup=setup, image=image, changes=normal, revision=rev,
blocked=blocked)
reads.append(setup)
return settings_state(setup, image, setup, series=3)
def describe_plan() -> dict:
b = st["blocks"]
lens = {0x68: len(b["event_index"]), 0x71: len(st["image"]) + 2,
0x82: len(b["trigger"]), 0x69: len(b["waveform"])}
if st["blocked"] and not dry_run:
raise ChangeRefused("; ".join(st["blocked"]) + " -- nothing sent")
steps = [] if st["blocked"] else [
{"sub": f"0x{sub:02X}", "what": what, "data_len": lens.get(sub, 0)}
for sub, what in _S3_SETTINGS_STEPS]
return {"action": "settings write", "blocked": list(st["blocked"]), "steps": steps,
"fields": field_rows(st["setup"], st["image"], 3, st["changes"]),
"revision": st["revision"], "warnings": [_S3_MENU_WARNING, _S3_TAIL_WARNING]}
def send() -> dict:
b = st["blocks"]
client.push_config_raw(b["event_index"], st["image"], b["trigger"], b["waveform"],
escaped=False) # every block read is logical
return {"subs": [f"0x{0xFF - sub:02X}" for sub, _ in _S3_SETTINGS_STEPS]}
def snapshot() -> dict:
before, after = st["setup"], reads[-1]
return {"fields": field_rows(before, st["image"], 3, st["changes"], now=after),
"before": before.hex(), "after": after.hex(),
"changed_offsets": [i for i in range(min(len(before), len(after)))
if before[i] != after[i]]}
return run_change(
kind=settings_change(), serial=serial, series=3, dry_run=dry_run,
even_if_already=False, audit=audit, address=address, caller=caller, sleep=sleep,
verify_timeout_s=verify_timeout_s, verify_interval_s=verify_interval_s,
read_serial=read_serial, read_state=read_state, describe_plan=describe_plan,
send=send, snapshot=snapshot,
# raised before the first frame goes out: audited as nothing sent
is_refusal=lambda e: isinstance(e, ImageRefused))
return self._run(address, op, retry=False)
def settings(self, address: UnitAddress, serial: str) -> UnitSettings:
"""The 1A read assembled into the logical block and decoded by the shared
settings codec (phase 5)."""
def op(client: Any) -> UnitSettings:
info = client.connect()
self._check(info.serial, serial, address)
cc = info.compliance_config
if cc is None:
raise MalformedReply("could not read the unit's settings (SUB 0x1A)")
mode = None
if cc.recording_mode is not None:
mode = S3_MODES.get(cc.recording_mode, f"unknown (0x{cc.recording_mode:02x})")
notes = {
label: value for label, value in (
("Project", cc.project), ("Client", cc.client), ("User Name", cc.operator),
("Seis Loc", cc.sensor_location), ("Extended Notes", cc.notes),
) if value is not None
}
content = client.read_compliance_content()
if not is_compliance_content(content):
raise UnitStateUnknown(f"{serial} {S3_SETTINGS_WHILE_MONITORING}")
v = field_values(content, 3)
name = decode_setup(content + bytes(2), verify=False).name # Series 3 reads no CRC
labels = {d["field"]: d["label"] for d in editable_fields(content, 3)}
notes = {labels[f]: v[f] for f in ("note_1", "note_2", "note_3", "note_4")}
code = content[5]
return UnitSettings(
serial=info.serial, series=3, setup_name=cc.setup_name, record_mode=mode,
sample_rate=cc.sample_rate, record_time_s=cc.record_time,
histogram_interval_s=cc.histogram_interval_sec, geo_trigger_ips=cc.trigger_level_geo,
serial=info.serial, series=3, setup_name=name or None,
record_mode=S3_MODES.get(code, f"unknown (0x{code:02x})"),
sample_rate=v["sample_rate"], record_time_s=v["record_time_s"],
histogram_interval_s=v["histogram_interval_s"], geo_trigger_ips=v["geo_trigger_ips"],
notes=notes,
detail={"record_mode_code": cc.recording_mode, "alarm_level_geo": cc.alarm_level_geo,
"geo_range": cc.geo_range},
detail={"record_mode_code": code, "alarm_level_geo": v["geo_alarm_ips"],
"geo_range": v["geo_range"], "editable": editable_fields(content, 3)},
)
return self._run(address, op)
+136 -5
View File
@@ -19,16 +19,28 @@ from typing import Any, Callable, Optional, TypeVar
from micromate.client import MicromateClient
from micromate.opcodes import OpcodeRefused
from micromate.protocol import THOR_CHUNK_SIZE
from micromate.protocol import ProtocolError as _MMProtocolError
from micromate.schedule import parse_schedule, schedule_conflicts
from micromate.setup_block import decode_setup
from micromate.setup_fields import (
SettingsValueError, changes_bytes, check_changes, editable_fields, encode_setup, field_rows,
settings_state,
)
from micromate.setup_fields import revision as settings_revision
from micromate.writes import (
is_call_home_content, plan_call_home_enabled, plan_start_monitoring, plan_stop_monitoring,
is_call_home_content, plan_call_home_enabled, plan_setup_push, plan_start_monitoring,
plan_stop_monitoring,
)
from minimateplus.transport import BaseTransport, SerialTransport, TcpTransport
from .errors import (
AuditIncomplete, CallHomeInProgress, ChangeUnconfirmed, DeviceError, EventNotFound,
MalformedReply, StaleEvent, UnitStateUnknown, WrongUnit, translate,
AuditIncomplete, BadRequest, CallHomeInProgress, ChangeRefused, ChangeUnconfirmed, DeviceError,
EventNotFound, MalformedReply, SettingsChanged, StaleEvent, UnitStateUnknown, WrongUnit,
translate,
)
from .change import (
CALL_HOME_MESSAGE, call_home_change, monitoring_change, run_change, settings_change,
)
from .change import CALL_HOME_MESSAGE, call_home_change, monitoring_change, run_change
from .events import iso_of, make_event_id, stamp_of
from .models import (CallHomeState, ChangeResult, DownloadedEvent, EventList, EventRef, UnitAddress,
UnitInfo, UnitSettings, UnitStatus)
@@ -268,7 +280,8 @@ def s4_status(client: Any, serial: str, run_state: bool = False) -> UnitStatus:
def s4_settings(client: Any, serial: str) -> UnitSettings:
s = client.get_setup()
content = client.get_setup_content()
s = decode_setup(content)
return UnitSettings(
serial=serial, series=4, setup_name=s.name, record_mode=s.record_mode_name,
sample_rate=s.sample_rate, record_time_s=s.record_time_s,
@@ -293,6 +306,7 @@ def s4_settings(client: Any, serial: str) -> UnitSettings:
"distance_ft": s.distance_ft,
"charge_weight_lb": s.charge_weight_lb,
"scaled_distance": s.scaled_distance,
"editable": editable_fields(content, 4),
},
)
@@ -452,3 +466,120 @@ def s4_change_call_home(client: Any, serial: str, *, enabled: bool, dry_run: boo
is_ring=lambda e: isinstance(e, RingDetected),
pre_send=lambda: client.read_unsolicited(),
snapshot=snapshot)
# ── Changing settings (phase 5) ──────────────────────────────────────────────
S4_SETTINGS_WHILE_MONITORING = ("is monitoring -- stop it first (a stop makes it call in if "
"call-home is on)")
_EDIT_BUFFER_WARNING = ("this reads the unit's keypad edit buffer: if someone is in its menu, "
"their unsaved edits are sent too")
_FACTORY = "factory.mmb"
def s4_change_settings(client: Any, serial: str, *, changes: dict, revision: Optional[str],
dry_run: bool, audit: Any, address: UnitAddress, caller: str,
sleep: Callable[[float], None], verify_timeout_s: float,
verify_interval_s: float) -> ChangeResult:
"""Series-4 pieces for the shared core: read the name, preferences, trigger
and setup blocks and the schedule; patch the setup's fields
(micromate.setup_fields); send THOR's setup push under the active setup's own
name; read the setup back. The plan is built from the read run_change made
just before it, and that same plan is the one sent.
Refused before anything is sent: a monitoring unit; values the unit does not
allow (BadRequest); a live call whose `revision` is not this read's
(SettingsChanged); the factory setup, a schedule that would load another
setup, an unreadable schedule, or a block SFM has not seen (ChangeRefused,
shown as `blocked` in a preview)."""
st: dict = {}
reads: list = []
def first_read() -> str:
name = client.get_active_setup_raw()
prefs = client.get_prefs_content()
trigger = client.get_trigger_content()
setup = client.get_setup_content()
try:
normal = check_changes(setup, 4, changes)
except SettingsValueError as exc:
raise BadRequest(f"{exc} -- nothing sent") from exc
# What the preview showed: the target name, the setup block, the changes. The
# preferences and trigger blocks are re-read here and sent back as read.
rev = settings_revision([name.encode("ascii", "replace"), setup, changes_bytes(normal)])
if not dry_run and revision != rev:
raise SettingsChanged(f"{serial}'s settings, or the changes asked for, are not the ones "
"previewed -- preview again; nothing sent")
image = encode_setup(setup, 4, normal)
blocked: list = []
warnings = [_EDIT_BUFFER_WARNING]
if name.strip().casefold() == _FACTORY:
blocked.append("this unit is running its factory setup; load any other setup on "
"its keypad, then try again")
try:
entries = parse_schedule(client.read_schedule())
except (_MMProtocolError, ValueError) as exc:
blocked.append(f"could not read this unit's schedule ({exc}) -- SFM will not change "
"a unit whose schedule it cannot check")
else:
conflicts = schedule_conflicts(entries, name)
for e in conflicts:
blocked.append(f"this unit's schedule loads {e.setup} at {e.time}, which would "
"replace this change")
for e in entries:
if "start_with_setup" in e.actions and e not in conflicts:
warnings.append(f"the unit's schedule loads this setup at {e.time}; the "
"change survives it")
plan = None
try:
plan = plan_setup_push(prefs, trigger, image, name)
except ValueError as exc:
blocked.append(f"this unit's {exc} -- SFM has not seen a block like it")
st.update(name=name, prefs=prefs, trigger=trigger, setup=setup, image=image,
changes=normal, revision=rev, blocked=blocked, warnings=warnings, plan=plan)
reads.append(setup)
return settings_state(setup, image, setup, series=4)
def read_state() -> str:
run = client.read_run_state().name
if run == "calling_home" or run.startswith("unknown"):
return run # the core refuses both; a write waits for a known state
if not st:
if run == "monitoring":
raise UnitStateUnknown(f"{serial} {S4_SETTINGS_WHILE_MONITORING} -- nothing sent")
return first_read()
now = client.get_setup_content()
reads.append(now)
return settings_state(st["setup"], st["image"], now, series=4)
def describe_plan() -> dict:
ok = st["plan"] is not None and not st["blocked"]
d = st["plan"].describe() if ok else {"action": "setup push", "steps": [], "warnings": []}
d["warnings"] = list(st["warnings"]) + list(d.get("warnings", []))
d.update(fields=field_rows(st["setup"], st["image"], 4, st["changes"]),
revision=st["revision"], blocked=list(st["blocked"]))
if st["blocked"] and not dry_run:
raise ChangeRefused("; ".join(st["blocked"]) + " -- nothing sent")
return d
def send() -> dict:
acks = client.protocol.execute(st["plan"])
return {"subs": [f"0x{a.sub:02X}" for a in acks], "data": [bytes(a.data).hex() for a in acks]}
def snapshot() -> dict:
before, after = st["setup"], reads[-1]
return {"fields": field_rows(before, st["image"], 4, st["changes"], now=after),
"before": before.hex(), "after": after.hex(),
"changed_offsets": _changed_offsets(before, after),
"prefs": st["prefs"].hex(), "trigger": st["trigger"].hex()}
return run_change(
kind=settings_change(), serial=serial, series=4, dry_run=dry_run, even_if_already=False,
audit=audit, address=address, caller=caller, sleep=sleep,
verify_timeout_s=verify_timeout_s, verify_interval_s=verify_interval_s,
read_serial=lambda: client.serial(refresh=True),
read_state=read_state, describe_plan=describe_plan, send=send,
is_refusal=lambda e: isinstance(e, OpcodeRefused),
is_ring=lambda e: isinstance(e, RingDetected),
pre_send=lambda: client.read_unsolicited(),
snapshot=snapshot)
+42
View File
@@ -34,6 +34,14 @@ Layout written to `<filename>.h5`:
sensor_location str
job_number int (only when read; kept while not shown)
job_number_enabled bool (Blastware prints the job number)
battery_volts, triggered_by, trigger_sources, trigger_level_geo_ips,
trigger_level_mic_psi, firmware_version, dsp_version, model,
calibration_date (ISO), calibrated_by
(each only when read from the event file)
histogram_interval_sec int (histograms)
/intervals (histograms, when read)
half_period/<ch> uint16 samples per interval; Hz = (sample rate / 2) / it
pvs_ips float32 each interval's vector sum, in/s
peak_tran_ips float (from 0C; authoritative)
peak_vert_ips float
peak_long_ips float
@@ -262,6 +270,24 @@ def write_event_hdf5(
if pi is not None and getattr(pi, "job_number", None) is not None:
attrs["job_number"] = int(pi.job_number)
attrs["job_number_enabled"] = bool(pi.job_number_enabled)
# Read from a Blastware file's identity and setup blocks; absent when not read.
for attr, value in (
("battery_volts", getattr(event, "battery_volts", None)),
("triggered_by", getattr(event, "triggered_by", None)),
("trigger_sources", getattr(event, "trigger_sources", None)),
("trigger_level_geo_ips", getattr(event, "trigger_level_geo", None)),
("trigger_level_mic_psi", getattr(event, "trigger_level_mic_psi", None)),
("histogram_interval_sec", getattr(event, "histogram_interval_sec", None)),
):
if value is not None:
attrs[attr] = value
di = getattr(event, "device_info", None)
if di is not None:
for attr in ("firmware_version", "dsp_version", "model", "calibrated_by"):
if getattr(di, attr, None):
attrs[attr] = getattr(di, attr)
if getattr(di, "calibration_date", None) is not None:
attrs["calibration_date"] = di.calibration_date.isoformat()
attrs["peak_tran_ips"] = float(pv.tran if pv and pv.tran is not None else 0.0)
attrs["peak_vert_ips"] = float(pv.vert if pv and pv.vert is not None else 0.0)
attrs["peak_long_ips"] = float(pv.long if pv and pv.long is not None else 0.0)
@@ -283,6 +309,22 @@ def write_event_hdf5(
compression="gzip", compression_opts=4, shuffle=True,
)
# /intervals — a histogram's per-interval detail as the file holds it:
# each channel's half-period in samples (frequency = (sample rate / 2)
# / half-period; 0 is Blastware's "N/A") and each interval's vector sum.
half_periods = getattr(event, "interval_half_periods", None)
interval_pvs = getattr(event, "interval_pvs", None)
if half_periods or interval_pvs:
igrp_iv = f.create_group("intervals")
if half_periods:
hgrp = igrp_iv.create_group("half_period")
for ch, hps in half_periods.items():
hgrp.create_dataset(ch, data=np.asarray(hps, dtype="uint16"),
compression="gzip", compression_opts=4, shuffle=True)
if interval_pvs:
igrp_iv.create_dataset("pvs_ips", data=np.asarray(interval_pvs, dtype="float32"),
compression="gzip", compression_opts=4, shuffle=True)
# /samples_int16 — optional raw ADC counts (preserved for analysis
# tools that want pre-conversion data). Cheap to include.
if include_int16:
+33 -6
View File
@@ -134,16 +134,43 @@ def _overlay_s4_record(ev: Any, record: dict) -> None:
ev.project_info.sensor_location = location
def _download_record_type(dl: DownloadedEvent) -> Optional[str]:
"""The download's own record type -- "Waveform" / "Histogram", as every stored
row has it -- from its file: a Series-3 file's STRT[18], a Series-4 name's
IDFW / IDFH. None when it does not read (then any row at its second counts)."""
if dl.series == 4:
ext = dl.filename.rsplit(".", 1)[-1].upper()
return {"IDFW": "Waveform", "IDFH": "Histogram"}.get(ext)
if not dl.bw_bytes:
return None
try:
from minimateplus.event_file_io import decode_blastware_bytes
return decode_blastware_bytes(dl.bw_bytes).record_type
except Exception: # noqa: BLE001 -- a check, not a decode
return None
def _same_type(row_type: Optional[str], mine: Optional[str]) -> bool:
"""An untyped row, or a download whose type does not read, matches
conservatively: it may be this event."""
return row_type is None or mine is None or row_type.casefold() == mine.casefold()
def persist_download(dl: DownloadedEvent, *, store: Any, db: Any) -> EventDownload:
# Never merge: a row for (serial, timestamp) means the event is stored, and
# whoever stored it first keeps it. No store call, no insert, no sidecar.
# Never merge: a row for (serial, timestamp, record type) means the event is
# stored, and whoever stored it first keeps it. No store call, no insert, no
# sidecar. The type matters since #51: a waveform and a histogram recorded in
# the same second (Histogram + Continuous) are two events.
kind = _download_record_type(dl)
if dl.timestamp is not None:
rows = db.query_events(serial=dl.serial, from_dt=dl.timestamp, to_dt=dl.timestamp, limit=1)
rows = db.query_events(serial=dl.serial, from_dt=dl.timestamp, to_dt=dl.timestamp, limit=10)
rows = [r for r in rows if _same_type(r.get("record_type"), kind)]
if rows:
return _already_stored(dl, rows[0])
# A histogram's row is stored at its file's time, a second before the unit's
# on most (#51), so the time above misses it; its Blastware name does not.
row = db.find_event_by_blastware_name(dl.serial, dl.filename)
# The Blastware name encodes the event's second (a second guard; before #51 a
# histogram's row sat a second off the unit's time). Both twins share the
# letterless name, so it too is held to the type.
row = db.find_event_by_blastware_name(dl.serial, dl.filename, record_type=kind)
if row is not None:
return _already_stored(dl, row)
if dl.series == 4:
+50 -133
View File
@@ -50,7 +50,7 @@ import tempfile
import threading
import time
from pathlib import Path
from typing import Mapping, Optional
from typing import Any, Dict, Mapping, Optional
# FastAPI / Pydantic
try:
@@ -426,6 +426,7 @@ _SERIAL_AWARE_PATHS = frozenset({
"/device/events", "/device/events/download",
"/device/monitor/start", "/device/monitor/stop",
"/device/call_home/state", "/device/call_home/enable", "/device/call_home/disable",
"/device/settings/change",
})
@@ -1112,145 +1113,61 @@ def device_event_blastware_file(
# ── Write endpoints ───────────────────────────────────────────────────────────
class DeviceConfigBody(BaseModel):
"""
Request body for POST /device/config.
All fields are optional — only supplied (non-null) fields are written to
the device. All other config bytes are round-tripped verbatim.
Recording parameters
--------------------
recording_mode : Recording mode enum. Values: 0=Single Shot, 1=Continuous, 3=Histogram, 4=Histogram+Continuous.
sample_rate : Samples per second. Valid values: 1024, 2048, 4096.
record_time : Record duration in seconds (e.g. 1.0, 2.0, 3.0).
Trigger / alarm thresholds and range (geo channels)
----------------------------------------------------
trigger_level_geo : Trigger threshold in in/s (e.g. 0.5).
alarm_level_geo : Alarm threshold in in/s (e.g. 1.0).
geo_range : Geophone range/sensitivity. 0=Normal 10.000 in/s, 1=Sensitive 1.250 in/s.
Project / operator strings (max 41 ASCII characters each)
----------------------------
project : Project description.
client_name : Client / company name.
operator : Operator / technician name.
seis_loc : Sensor location description.
notes : Extended notes.
"""
# Recording parameters
recording_mode: Optional[int] = None
sample_rate: Optional[int] = None
record_time: Optional[float] = None
histogram_interval_sec: Optional[int] = None # seconds: 2, 5, 15, 60, 300, 900 (mode-gated)
# Threshold parameters / geo range
trigger_level_geo: Optional[float] = None
alarm_level_geo: Optional[float] = None
geo_range: Optional[int] = None # 0=Normal 10.000 in/s, 1=Sensitive 1.250 in/s
# Project / operator strings
project: Optional[str] = None
client_name: Optional[str] = None
operator: Optional[str] = None
seis_loc: Optional[str] = None
notes: Optional[str] = None
_CONFIG_RETIRED = ("retired: change a unit's settings by serial with POST /device/settings/change "
"(audited, previewed, read back)")
@app.post("/device/config")
def device_config(
body: DeviceConfigBody,
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: int = Query(38400, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
serial: Optional[str] = Query(None, description=_SERIAL_CHECK_DOC),
) -> dict:
"""
Read the current device config, apply any supplied changes to the compliance
block, and write the full config back.
Only non-null fields in the JSON body are modified. All other config bytes
are round-tripped verbatim from the device.
Supply either *port* (serial) or *host* (TCP/modem).
Example body (all fields optional — include only what you want to change):
{
"recording_mode": 1,
"sample_rate": 1024,
"record_time": 3.0,
"trigger_level_geo": 0.5,
"alarm_level_geo": 1.0,
"project": "Bridge Inspection 2026",
"client_name": "City of Portland",
"operator": "Brian Harrison",
"seis_loc": "South Abutment",
"notes": "Pre-blast baseline"
}
Returns:
{"status": "ok", "updated_fields": {...}} on success.
Raises:
502 on protocol errors (timeout, bad ack, etc.).
422 if neither port nor host is provided.
"""
changed = body.model_dump(exclude_none=True)
conn_key = _live_cache.make_conn_key(host, tcp_port, port, baud)
log.info("POST /device/config port=%s host=%s fields=%s", port, host, list(changed.keys()))
try:
def _do():
with _build_client(port, baud, host, tcp_port) as client:
info = client.connect()
_require_series3(info.serial, serial)
client.apply_config(
recording_mode=body.recording_mode,
sample_rate=body.sample_rate,
record_time=body.record_time,
histogram_interval_sec=body.histogram_interval_sec,
trigger_level_geo=body.trigger_level_geo,
alarm_level_geo=body.alarm_level_geo,
geo_range=body.geo_range,
project=body.project,
client_name=body.client_name,
operator=body.operator,
seis_loc=body.seis_loc,
notes=body.notes,
)
_run_with_retry(_do, is_tcp=_is_tcp(host))
except HTTPException:
raise
except ProtocolError as exc:
raise HTTPException(status_code=502, detail=f"Protocol error: {exc}") from exc
except OSError as exc:
raise HTTPException(status_code=502, detail=f"Connection error: {exc}") from exc
except ValueError as exc:
raise HTTPException(status_code=422, detail=str(exc)) from exc
except Exception as exc:
raise HTTPException(status_code=500, detail=f"Device error: {exc}") from exc
# Config was written to the device — the cached compliance config is now stale.
conn_key = SFMCache.make_conn_key(host, tcp_port, port, baud)
get_cache().mark_config_dirty(conn_key)
return {
"status": "ok",
"updated_fields": changed,
}
def device_config() -> JSONResponse:
"""Retired (phase 5, 2026-11-03). It wrote a MiniMate's settings through an
encoder #46 found wrong, unaudited, with no read-back, retrying the whole
write on a TCP error. Use POST /device/settings/change."""
return JSONResponse(status_code=410, content={"detail": _CONFIG_RETIRED})
# Keep the old endpoint alive under its old URL for anything already calling it
@app.post("/device/config/project")
def device_config_project(
body: DeviceConfigBody,
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: int = Query(38400, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
def device_config_project() -> JSONResponse:
"""Retired with POST /device/config -- use POST /device/settings/change."""
return JSONResponse(status_code=410, content={"detail": _CONFIG_RETIRED})
class SettingsChangeBody(BaseModel):
"""POST /device/settings/change. `changes` maps field -> new value, using
the field names in GET /device/settings' `detail.editable`. `revision` is the
one a dry run (the preview) returned; a live change without it is refused."""
changes: Dict[str, Any]
revision: Optional[str] = None
@app.post("/device/settings/change")
def device_settings_change(
body: SettingsChangeBody,
serial: str = Query(..., description=_SERIAL_DOC),
host: Optional[str] = Query(None, description="TCP host — modem IP"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
serial: Optional[str] = Query(None, description=_SERIAL_CHECK_DOC),
) -> dict:
"""Deprecated alias for POST /device/config — use that instead."""
return device_config(body=body, port=port, baud=baud, host=host, tcp_port=tcp_port, serial=serial)
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: Optional[int] = Query(None, description="Serial baud rate"),
dry_run: bool = Query(False, description="Preview: old -> new and a revision; send nothing"),
caller: Optional[str] = Query(None, description="Who is asking (recorded in the audit row)"),
):
"""Change a unit's settings by serial, both series (spec row 10, phase 5).
Preview first (`dry_run=true`): it reads the unit and returns, per field, the
value it holds and the value it would get, any warnings, anything that blocks
the change, and a `revision`. Then send the same body live with that
revision: identity read first, refused if the unit is monitoring or its
settings changed since the preview (409), sent once, never retried, read back.
Statuses as /device/monitor/start; a change that went out but was not
confirmed carries `sent` and `audit_id`."""
resp = _change_response(lambda: _device_access().change_settings(
_unit_address(port, baud, host, tcp_port), serial, changes=body.changes,
revision=body.revision, dry_run=dry_run, caller=caller or "api"))
if not dry_run:
try: # a by-host read must not serve stale settings
get_cache().mark_config_dirty(_live_cache.make_conn_key(host, tcp_port, port, baud))
except Exception as exc: # noqa: BLE001 -- the change's answer stands
log.warning("could not mark the cached config dirty: %s", exc)
return resp
# ── Monitoring endpoints ───────────────────────────────────────────────────────
+11 -2
View File
@@ -1020,8 +1020,18 @@
<div id="tab-config" class="tab-pane">
<div id="cfg-settings" style="display:none; margin-bottom:12px">
<div class="cfg-section-title">On the unit (read by serial)</div>
<div class="cfg-section-title" id="cfg-settings-title">On the unit (read by serial)</div>
<div class="dev-table" id="cfg-settings-table"></div>
<!-- Phase 5: change the unit's settings by serial -- Preview, then Send (audited, read back). -->
<div class="cfg-section-title" id="cfg-edit-title" hidden>Change settings on this unit</div>
<div class="cfg-grid" id="cfg-edit" hidden></div>
<div class="cfg-actions" id="cfg-edit-actions" hidden>
<button class="btn btn-ghost" id="cfg-preview-btn" disabled>Preview</button>
<button class="btn btn-success" id="cfg-send-btn" disabled>Send to Unit</button>
<span id="cfg-edit-note"></span>
</div>
<div class="dev-table" id="cfg-preview"></div>
<div class="dev-table" id="cfg-result"></div>
</div>
<div class="cfg-grid" id="cfg-form">
@@ -1129,7 +1139,6 @@
<div class="cfg-actions">
<button class="btn btn-ghost" id="cfg-read-btn" onclick="readConfig()" disabled>Read from Device</button>
<button class="btn btn-success" id="cfg-write-btn" onclick="writeConfig()" disabled>Write to Device</button>
<button class="btn btn-ghost" onclick="clearConfigForm()">Clear Form</button>
<span id="cfg-status"></span>
</div>
+62 -3
View File
@@ -47,7 +47,7 @@ const DEVICE_ROUTES = {
call_home_state: ['GET', '/device/call_home/state', true],
call_home_on: ['POST', '/device/call_home/enable', true],
call_home_off: ['POST', '/device/call_home/disable', true],
config_write: ['POST', '/device/config', false],
settings_change: ['POST', '/device/settings/change', true],
event_waveform: ['GET', '/device/event/{index}/waveform', false],
event_file: ['GET', '/device/event/{index}/blastware_file', false],
};
@@ -88,9 +88,9 @@ function controlsFor(unit) {
// by host, the legacy read is Series 3's; by serial, both series (phase 4)
callHomeRead: series === 3 || (serialMode && series === 4),
callHomeChange: serialMode && (series === 3 || series === 4),
configWrite: false,
configWrite: serialMode && (series === 3 || series === 4),
callHomeWrite: false,
reasons: { configWrite: 'Coming in phase 5 (#46)',
reasons: { configWrite: 'By serial only: Preview, then Send (audited).',
callHomeWrite: 'By serial: use Call-home On / Off (audited). Other call-home fields wait for the THOR round.' },
};
}
@@ -101,6 +101,15 @@ function changeSummary(body) {
const subs = ((body.plan || {}).steps || []).map(s => s.sub).join(', ');
return `${body.action}: dry run — would send ${subs}`;
}
if (body.action === 'change settings') { // phase 5: the state is a read-back verdict
if (body.outcome === 'skipped') return 'change settings: the unit already holds these — nothing sent';
if (body.outcome === 'sent' && body.verified === 'ok') {
return `change settings: confirmed — the unit holds what was sent (audit ${id8})`;
}
if (body.verified === 'mismatch') {
return `change settings: sent, but the unit reads ${body.state_after} — see what it holds (audit ${id8})`;
}
}
if (body.outcome === 'skipped') return `${body.action}: already ${body.state_before} — nothing sent`;
if (body.outcome === 'sent' && body.verified === 'ok') {
return `${body.action}: confirmed — ${body.state_before} → ${body.state_after} (audit ${id8})`;
@@ -209,4 +218,54 @@ function callHomeRows(state) {
: d.reason || `Unknown (byte 5 = ${d.byte5 ?? '?'})`;
return [['Call-home', sw], ['Dial string', s.dial_string || '—'], ['Series', s.series]];
}
// ── The Config tab's edit form, by serial (phase 5) ──────────────────────────
// The fields the server says this unit can change, in its order, with their
// limits (UnitSettings.detail.editable).
function settingsFormFields(st) {
return (((st || {}).detail || {}).editable || []).map(f => ({ ...f }));
}
// Only what the operator changed, typed as the server expects. Numbers compare
// as numbers (0.30 is 0.3); a number that does not parse is left out (the
// preview shows exactly what would change); read-only fields never count.
function settingsChanges(fields, edited) {
const out = {};
const e = edited || {};
for (const f of fields || []) {
if (f.readonly || !(f.field in e)) continue;
let v = e[f.field];
if (f.kind === 'number' || (f.kind === 'choice' && typeof f.value === 'number')) {
if (v === '' || v == null) continue;
v = Number(v);
if (!Number.isFinite(v) || v === Number(f.value)) continue;
} else if (f.kind === 'bool') {
v = Boolean(v);
if (v === Boolean(f.value)) continue;
} else {
v = String(v);
if (v === String(f.value == null ? '' : f.value)) continue;
}
out[f.field] = v;
}
return out;
}
const _dash = v => (v == null || v === '' ? '—' : v);
// A preview (dry run): one row per field, [label, the unit holds, it would get].
function settingsPreviewRows(body) {
return Object.values(((body || {}).plan || {}).fields || {}).map(r => [r.label, _dash(r.old), _dash(r.new)]);
}
// Why a preview would not be sent ('' when nothing blocks it).
function settingsBlockedText(body) {
return (((body || {}).plan || {}).blocked || []).join('; ');
}
// After a send: [label, the unit held, SFM sent, the unit now holds].
function settingsResultRows(body) {
const fields = ((((body || {}).detail || {}).snapshot || {}).fields) || {};
return Object.values(fields).map(r => [r.label, _dash(r.old), _dash(r.new), _dash(r.now)]);
}
/* </device-routing> */
+178 -65
View File
@@ -90,8 +90,7 @@ function applyControls() {
badge.textContent = series ? `Series ${series}` : '';
document.getElementById('hangup-btn').hidden = !c.hangup;
setDiagButtonsEnabled(c.diagnostics);
const cw = document.getElementById('cfg-write-btn');
cw.disabled = !c.configWrite; cw.title = c.reasons.configWrite;
updateSettingsButtons();
const hw = document.getElementById('ch-write-btn');
hw.disabled = !c.callHomeWrite; hw.title = c.reasons.callHomeWrite;
const chr = document.getElementById('ch-read-btn');
@@ -163,18 +162,24 @@ async function changeCallHome(on) {
await readCallHomeBySerial({ quiet: true });
}
// The Config tab by serial (#6): settings are read-only until phase 5, so the
// empty legacy edit form stays hidden and the settings box shows from the start.
// A different unit's settings are never left on screen.
// The Config tab by serial (#6; phase 5): the settings box shows from the start
// and the empty legacy form stays hidden. A different unit's settings, form,
// preview or result are never left on screen.
let settingsShownFor = null;
let settingsShown = null; // the UnitSettings the edit form was built from
let settingsPreview = null; // {serial, changes (JSON), revision, blocked}: what a Send would send
function applyConfigPanes() {
const serial = normSerial(currentUnit().serial);
const p = serialPanes(Boolean(serial), Boolean(serial) && settingsShownFor === serial);
document.getElementById('cfg-form').style.display = p.configForm ? '' : 'none';
document.getElementById('cfg-settings').style.display = p.settingsBox ? 'block' : 'none';
if (p.settingsPlaceholder) {
settingsShownFor = null;
settingsShownFor = null; settingsShown = null; settingsPreview = null;
renderTextTable('cfg-settings-table', [['Settings', 'Not read yet — press Read from Device']]);
document.getElementById('cfg-settings-title').textContent = 'On the unit (read by serial)';
for (const id of ['cfg-edit-title', 'cfg-edit', 'cfg-edit-actions']) document.getElementById(id).hidden = true;
renderTextTable('cfg-preview', []);
renderTextTable('cfg-result', []);
}
}
@@ -783,25 +788,185 @@ function clearConfigForm() {
setCfgStatus('');
}
// Serial mode: the shared UnitSettings, read-only (writes wait for phase 5).
async function readSettingsBySerial() {
// Serial mode: the shared UnitSettings, and the form to change them (phase 5).
// `quiet`: the re-read after a send -- the send's own result stays on screen.
async function readSettingsBySerial({ quiet = false } = {}) {
const btn = document.getElementById('cfg-read-btn');
btn.disabled = true;
setCfgStatus('Reading settings from the unit…');
if (!quiet) setCfgStatus('Reading settings from the unit…');
try {
const st = await deviceFetch('settings');
renderTextTable('cfg-settings-table', settingsRows(st));
settingsShownFor = normSerial(st.serial);
settingsShown = st;
settingsPreview = null;
document.getElementById('cfg-settings-title').textContent =
`On the unit ${st.serial} — read ${new Date().toTimeString().slice(0, 5)}`;
renderSettingsForm(st);
renderTextTable('cfg-preview', []);
if (!quiet) renderTextTable('cfg-result', []);
document.getElementById('cfg-settings').style.display = 'block';
document.getElementById('cfg-form').style.display = 'none';
setCfgStatus(`Settings read from ${st.serial}.`, 'ok');
if (!quiet) setCfgStatus(`Settings read from ${st.serial}.`, 'ok');
} catch (e) {
setCfgStatus(`Read failed: ${e.message}`, 'error');
if (!quiet) setCfgStatus(`Read failed: ${e.message}`, 'error');
else renderTextTable('cfg-preview', [['Re-read', `failed: ${e.message}`]]);
} finally {
btn.disabled = false;
updateSettingsButtons();
}
}
// ── Changing settings by serial (phase 5) ─────────────────────────────────────
function settingsInput(f) {
let el;
if (f.kind === 'choice') {
el = document.createElement('select');
for (const c of f.choices || []) {
const o = document.createElement('option');
o.value = String(c.value); o.textContent = c.label;
el.appendChild(o);
}
el.value = String(f.value);
} else if (f.kind === 'bool') {
el = document.createElement('input');
el.type = 'checkbox'; el.checked = Boolean(f.value);
} else {
el = document.createElement('input');
el.type = f.kind === 'number' ? 'number' : 'text';
if (f.kind === 'number') {
el.step = f.step != null ? String(f.step) : 'any';
if (f.min != null) el.min = String(f.min);
if (f.max != null) el.max = String(f.max);
}
if (f.maxlength) el.maxLength = f.maxlength;
el.value = f.value == null ? '' : String(f.value);
}
el.id = `cfg-f-${f.field}`;
el.dataset.field = f.field;
el.disabled = Boolean(f.readonly);
if (f.readonly) el.title = 'Shown, not changed yet';
el.addEventListener(f.kind === 'text' || f.kind === 'number' ? 'input' : 'change', settingsEdited);
return el;
}
function renderSettingsForm(st) {
const box = document.getElementById('cfg-edit');
box.innerHTML = '';
for (const f of settingsFormFields(st)) {
const wrap = document.createElement('div');
wrap.className = 'cfg-field';
const label = document.createElement('label');
label.textContent = f.unit ? `${f.label} (${f.unit})` : f.label;
label.htmlFor = `cfg-f-${f.field}`;
wrap.append(label, settingsInput(f));
box.appendChild(wrap);
}
for (const id of ['cfg-edit-title', 'cfg-edit', 'cfg-edit-actions']) document.getElementById(id).hidden = false;
}
function editedSettings() {
const out = {};
for (const el of document.querySelectorAll('#cfg-edit [data-field]')) {
out[el.dataset.field] = el.type === 'checkbox' ? el.checked : el.value;
}
return out;
}
function currentSettingsChanges() {
return settingsShown ? settingsChanges(settingsFormFields(settingsShown), editedSettings()) : {};
}
// Any edit after a preview: the preview no longer covers what Send would send.
function settingsEdited() {
settingsPreview = null;
renderTextTable('cfg-preview', []);
updateSettingsButtons();
}
function updateSettingsButtons() {
const c = controlsFor(currentUnit());
const serial = normSerial(currentUnit().serial);
const shown = Boolean(settingsShown) && normSerial(settingsShown.serial) === serial;
const changes = shown ? currentSettingsChanges() : {};
const preview = document.getElementById('cfg-preview-btn');
preview.disabled = !(c.configWrite && shown && Object.keys(changes).length) || changeInFlight;
preview.title = c.reasons.configWrite;
const ready = Boolean(settingsPreview) && settingsPreview.serial === serial && !settingsPreview.blocked
&& settingsPreview.changes === JSON.stringify(changes);
document.getElementById('cfg-send-btn').disabled = !(c.configWrite && ready) || changeInFlight;
}
function postSettingsChange(changes, { dryRun, revision }) {
return deviceRequest('settings_change', dryRun ? { dry_run: 'true' } : {}, {
headers: { 'Content-Type': 'application/json' },
body: JSON.stringify(revision ? { changes, revision } : { changes }),
});
}
// A dry run: SFM re-reads the unit and says what would change. Nothing is sent.
async function previewSettings() {
const changes = currentSettingsChanges();
const serial = normSerial(currentUnit().serial);
renderTextTable('cfg-result', []);
setCfgStatus('Previewing — reading the unit…');
try {
const r = await postSettingsChange(changes, { dryRun: true });
const body = await r.json().catch(() => ({}));
if (!r.ok) {
setCfgStatus(changeErrorText('Preview', r.status, body, currentUnit(), r.statusText), 'error');
return;
}
const blocked = settingsBlockedText(body);
renderTextTable('cfg-preview', [
...settingsPreviewRows(body).map(([label, old, now]) => [label, `${old} → ${now}`]),
...((body.plan || {}).warnings || []).map(w => ['Note', w]),
...(blocked ? [['Will not send', blocked]] : []),
]);
settingsPreview = { serial, changes: JSON.stringify(changes), revision: (body.plan || {}).revision,
blocked: Boolean(blocked) };
setCfgStatus(blocked ? 'Preview: this change cannot be sent (see above). Nothing was sent.'
: 'Preview ready — nothing sent yet. Check it, then Send to Unit.',
blocked ? 'error' : 'ok');
} catch (e) {
setCfgStatus(`Preview failed: ${e.message}`, 'error');
} finally {
updateSettingsButtons();
}
}
// One audited send, never retried; the body says what the unit now holds.
async function sendSettings() {
const p = settingsPreview;
if (!p) return;
const changes = JSON.parse(p.changes);
const names = settingsFormFields(settingsShown).filter(f => f.field in changes).map(f => f.label);
if (!confirm(`Send these changes to ${p.serial}?\n\n${names.join('\n')}`)) return;
changeInFlight = true; applyControls();
setCfgStatus(`Sending to ${p.serial}…`);
let body = {};
try {
const r = await postSettingsChange(changes, { dryRun: false, revision: p.revision });
body = await r.json().catch(() => ({}));
if (body.outcome) {
renderTextTable('cfg-result', settingsResultRows(body).map(
([label, old, sent, now]) => [label, `${old} → ${sent} · the unit now holds ${now}`]));
setCfgStatus(changeSummary(body), r.ok ? 'ok' : 'error');
} else {
setCfgStatus(changeErrorText('Change settings', r.status, body, currentUnit(), r.statusText), 'error');
}
} catch (e) {
// No reply is not "nothing sent": the request may have reached the unit.
setCfgStatus(`Change settings: no reply from SFM (${e.message}) — it may have been sent; `
+ 'read the unit\'s settings and GET /db/device_commands', 'error');
}
settingsPreview = null;
renderTextTable('cfg-preview', []);
changeInFlight = false; applyControls();
if (body.outcome) await readSettingsBySerial({ quiet: true });
}
async function readConfig() {
if (!devHost()) { setCfgStatus('Not connected.', 'error'); return; }
if (serialMode()) { await readSettingsBySerial(); return; }
@@ -822,60 +987,6 @@ async function readConfig() {
}
}
async function writeConfig() {
if (!devHost()) { setCfgStatus('Not connected.', 'error'); return; }
// Build body — only include fields that have values
const body = {};
const rm = qs('cfg-recording-mode').value;
if (rm !== '') body.recording_mode = parseInt(rm, 10);
const sr = qs('cfg-sample-rate').value;
if (sr) body.sample_rate = parseInt(sr, 10);
const hi = qs('cfg-histogram-interval').value;
if (hi !== '') body.histogram_interval_sec = parseInt(hi, 10);
const rt = qs('cfg-record-time').value;
if (rt) body.record_time = parseFloat(rt);
const trig = qs('cfg-trigger').value;
if (trig) body.trigger_level_geo = parseFloat(trig);
const alarm = qs('cfg-alarm').value;
if (alarm) body.alarm_level_geo = parseFloat(alarm);
const gr = qs('cfg-geo-range').value;
if (gr !== '') body.geo_range = parseInt(gr, 10);
const proj = qs('cfg-project').value.trim();
if (proj) body.project = proj;
const cli = qs('cfg-client').value.trim();
if (cli) body.client_name = cli;
const op = qs('cfg-operator').value.trim();
if (op) body.operator = op;
const sl = qs('cfg-seis-loc').value.trim();
if (sl) body.seis_loc = sl;
const notes = qs('cfg-notes').value.trim();
if (notes) body.notes = notes;
if (Object.keys(body).length === 0) {
setCfgStatus('No fields to write — fill in at least one field.', 'error');
return;
}
const fieldsStr = Object.keys(body).join(', ');
setCfgStatus(`Writing ${Object.keys(body).length} field(s)…`);
document.getElementById('cfg-write-btn').disabled = true;
try {
await deviceFetch('config_write', {}, {
headers: { 'Content-Type': 'application/json' },
body: JSON.stringify(body),
});
setCfgStatus(`Written: ${fieldsStr}`, 'ok');
// Re-read device info so Device tab and bar refresh
await readConfig();
} catch(e) {
setCfgStatus(`Write failed: ${e.message}`, 'error');
} finally {
document.getElementById('cfg-write-btn').disabled = false;
}
}
// ── Call Home form ─────────────────────────────────────────────────────────────
function setChStatus(msg, type) {
const el = document.getElementById('ch-status');
@@ -2339,6 +2450,8 @@ for (const id of ['dev-serial', 'dev-host', 'dev-port']) {
// New controls are wired here, not with onclick= in the HTML (no inline JS).
document.getElementById('ch-on-btn').addEventListener('click', () => changeCallHome(true));
document.getElementById('ch-off-btn').addEventListener('click', () => changeCallHome(false));
document.getElementById('cfg-preview-btn').addEventListener('click', previewSettings);
document.getElementById('cfg-send-btn').addEventListener('click', sendSettings);
applyControls();
// Reflect any persisted mic-unit preference in the header pill on load
+113 -3
View File
@@ -17,6 +17,59 @@ from minimateplus.models import ComplianceConfig, DeviceInfo, Event, MonitorStat
SETUP_FIXTURE = Path(__file__).parent / "fixtures" / "micromate-setup" / "um20147_baseline.bin"
THOR_IDF = Path(__file__).parent / "fixtures" / "thor-idf"
PUSH_FIXTURE = Path(__file__).parent / "fixtures" / "micromate-writes" / "setup-push-overwrite-test1.json"
def s4_push_reads() -> dict:
"""UM12947's reads (content, by SUB) just before THOR's setup push: 0x08 prefs,
0x2E trigger, 0x1A setup, 0x41 active name."""
import json
ex = json.loads(PUSH_FIXTURE.read_text())["exchanges"]
start = next(i for i, e in enumerate(ex) if e["sub"] == 0xDA)
return {e["sub"]: bytes.fromhex(e["response_data"])[11:] for e in ex[:start]}
_S3_BLOCKS = None
def s3_settings_blocks() -> dict:
"""BE9441's four settings blocks on 2026-10-26, as SFM's reads return them:
the 1A read Blastware took right after its second write (assembled, 2,090 B),
and the event index / trigger / waveform blocks that write sent back (each a
write is the read plus two bytes)."""
global _S3_BLOCKS
if _S3_BLOCKS is None:
from minimateplus.framing import S3FrameParser
from minimateplus.protocol import assemble_compliance_content
from test_minimate_write_frames import WRITES, _payload
fix = Path(__file__).parent / "fixtures" / "minimate-bench-10-26-26-histogram"
reads, cur = [], None
for f in S3FrameParser().feed((fix / "unit_replies.bin").read_bytes()):
if f.sub != 0xE5:
continue
if len(f.data) == 11:
cur = []
reads.append(cur)
else:
cur.append(bytes(f.data))
sent = {_payload(f)[2]: _payload(f)[16:] for f in WRITES[13:26]}
_S3_BLOCKS = {"event_index": sent[0x68][:-2], "compliance": assemble_compliance_content(reads[2]),
"trigger": sent[0x82][:-2], "waveform": sent[0x69][:-2]}
return dict(_S3_BLOCKS)
def s3_device_info_answer(serial: bytes = b"BE9441") -> bytes:
"""What a MONITORING MiniMate returns for a 1A read, assembled: its device-info
block (BE9441 10-26: reads 3-7 start 0e 'BE9441'), 2,090 bytes."""
return (b"\x0e" + serial).ljust(2090, b"\x00")
def schedule_record(time_slot: int, action: int, setup: str = "") -> bytes:
"""One 260-byte schedule.dat record (micromate.schedule's layout)."""
rec = bytearray(260)
rec[4], rec[5], rec[6], rec[7] = time_slot, 3, action, len(setup)
rec[8:8 + len(setup)] = setup.encode("ascii")
return bytes(rec)
THOR_WRITES = Path(__file__).parent / "fixtures" / "micromate-writes"
@@ -97,9 +150,13 @@ def default_s3_events():
class FakeMiniMateClient(_Base):
def __init__(self, serial="BE18193", *, monitoring=False, compliance="default", events=None,
monitor_states=None, write_error=None, serial_reported=None, wake_errors=None,
bare_requests_ignored=False, call_home_raw=None, **kw):
bare_requests_ignored=False, call_home_raw=None, settings_blocks=None,
monitoring_settings=False, **kw):
super().__init__(**kw)
self.serial = serial
self.settings_blocks = s3_settings_blocks() if settings_blocks is None else dict(settings_blocks)
self.monitoring_settings = monitoring_settings
self.pushed = None
# As a monitoring MiniMate (measured 2026-04-08): on a fresh connection a
# read before SESSION_RESET + POLL goes unanswered. Off unless a test asks.
self.bare_requests_ignored = bare_requests_ignored
@@ -165,6 +222,23 @@ class FakeMiniMateClient(_Base):
self._write("call_home")
self.call_home_raw = bytes(image) # read back as the unit would store it
def read_compliance_content(self) -> bytes:
self._bare_read("read_compliance_content")
return s3_device_info_answer() if self.monitoring_settings else self.settings_blocks["compliance"]
def read_settings_blocks(self) -> dict:
self._bare_read("read_settings_blocks")
blocks = dict(self.settings_blocks)
if self.monitoring_settings:
blocks["compliance"] = s3_device_info_answer()
return blocks
def push_config_raw(self, event_index, compliance, trigger, waveform, *, escaped=False) -> None:
self.pushed_escaped = escaped
self.pushed = (bytes(event_index), bytes(compliance), bytes(trigger), bytes(waveform))
self._write("push_config_raw")
self.settings_blocks["compliance"] = bytes(compliance)[:2090] # read back as the unit stores it
def get_monitor_status(self) -> MonitorStatus:
self._bare_read("get_monitor_status")
state = self.monitor_states.pop(0) if len(self.monitor_states) > 1 else self.monitor_states[0]
@@ -269,6 +343,10 @@ class _FakeProtocol:
old = self._owner.call_home
self._owner.call_home = bytes(st.data[:118]) + bytes(~b & 0xFF for b in old[118:120]) \
+ bytes(st.data[120:])
if st.sub == 0x71: # the unit stores the setup and computes its own CRC
from micromate.setup_block import with_crc
old = self._owner.setup
self._owner.setup = with_crc(old[:3] + bytes(st.data[3:2090]) + old[2090:2092])
return [type("Ack", (), {"sub": s.ack_sub, "data": bytes(11)})() for s in plan.steps]
def read_call_home_config(self):
@@ -279,10 +357,20 @@ class _FakeProtocol:
class FakeMicromateClient(_Base):
def __init__(self, serial="UM20147", *, monitoring=False, events=5,
unsolicited=b"", event_refs=None, run_states=None,
serial_reported=None, execute_error=None, call_home=None, **kw):
serial_reported=None, execute_error=None, call_home=None, setup=None,
prefs=None, trigger=None, active_name=None, schedule_body=None,
schedule_error=None, **kw):
super().__init__(**kw)
self.unit_serial = serial # not `serial`: that is the client's method
self.call_home = um12947_call_home() if call_home is None else call_home
push = s4_push_reads()
self.setup = SETUP_FIXTURE.read_bytes()[11:] if setup is None else setup
self.prefs = push[0x08] if prefs is None else prefs
self.trigger = push[0x2E] if trigger is None else trigger
self.active_name = (push[0x41].split(b"\x00")[0].decode("ascii")
if active_name is None else active_name)
self.schedule_body = bytes(524) if schedule_body is None else schedule_body
self.schedule_error = schedule_error
self.run_states = list(run_states) if run_states else [0x00]
self.serial_reported = serial if serial_reported is None else serial_reported
self.execute_error = execute_error
@@ -334,7 +422,29 @@ class FakeMicromateClient(_Base):
def get_setup(self):
self._step("get_setup")
return decode_setup(SETUP_FIXTURE.read_bytes()[11:])
return decode_setup(self.setup)
def get_setup_content(self) -> bytes:
self._step("get_setup_content")
return self.setup
def get_prefs_content(self) -> bytes:
self._step("get_prefs_content")
return self.prefs
def get_trigger_content(self) -> bytes:
self._step("get_trigger_content")
return self.trigger
def get_active_setup_raw(self) -> str:
self._step("get_active_setup_raw")
return self.active_name
def read_schedule(self) -> bytes:
self._step("read_schedule")
if self.schedule_error is not None:
raise self.schedule_error
return self.schedule_body
def read_unsolicited(self) -> bytes:
self._step("read_unsolicited")
Binary file not shown.
+116
View File
@@ -0,0 +1,116 @@
<?xml version="1.0" encoding="UTF-8"?>
<Event>
<FileVersion>8.0</FileVersion>
<EventType>Full Histogram</EventType>
<SerialNumber>BE18190</SerialNumber>
<Version>V 10.72-8.17 MiniMate Plus</Version>
<FileName>T190LD42.T00H</FileName>
<HistogramStartTime>13:29:24</HistogramStartTime>
<HistogramStartDate>2025-12-08</HistogramStartDate>
<HistogramStopTime>13:29:37</HistogramStopTime>
<HistogramStopDate>2025-12-08</HistogramStopDate>
<Channels>
<Channel>Tran</Channel>
<Channel>Vert</Channel>
<Channel>Long</Channel>
<Channel>MicL</Channel>
</Channels>
<NumberofIntervals>1.00</NumberofIntervals>
<IntervalSize>1 minute</IntervalSize>
<SampleRate>2048 sps</SampleRate>
<BatteryLevel>6.7 Volts</BatteryLevel>
<Calibration>June 13, 2025 by Instantel</Calibration>
<Units>in/s and dB(L)</Units>
<Project>I-80-North Fork-Area 3-462Richardsvilel</Project>
<Client>Fay Company</Client>
<UserName>Terra-Mechanics Inc.- Harrison</UserName>
<SeisLoc>Loc #8 - Area 3- 462 Richardsville Road</SeisLoc>
<GeoRange>
<Value>10.000</Value>
<Units>in/s</Units>
</GeoRange>
<TranPPV>
<Value>1.280</Value>
<Units>in/s</Units>
</TranPPV>
<VertPPV>
<Value>2.615</Value>
<Units>in/s</Units>
</VertPPV>
<LongPPV>
<Value>1.120</Value>
<Units>in/s</Units>
</LongPPV>
<TranZCFreq>
<Value>15.5</Value>
<Units>Hz</Units>
</TranZCFreq>
<VertZCFreq>
<Value>64</Value>
<Units>Hz</Units>
</VertZCFreq>
<LongZCFreq>
<Value>17.7</Value>
<Units>Hz</Units>
</LongZCFreq>
<TranPeakTime>13:29:37</TranPeakTime>
<TranPeakDate>2025-12-08</TranPeakDate>
<VertPeakTime>13:29:37</VertPeakTime>
<VertPeakDate>2025-12-08</VertPeakDate>
<LongPeakTime>13:29:37</LongPeakTime>
<LongPeakDate>2025-12-08</LongPeakDate>
<PeakVectorSum>
<Value>2.644</Value>
<Units>in/s</Units>
</PeakVectorSum>
<PeakVectorSumTime>13:29:37</PeakVectorSumTime>
<PeakVectorSumDate>2025-12-08</PeakVectorSumDate>
<Microphone>Linear Weighting</Microphone>
<MicLPSPL>
<Value>107.0</Value>
<Units>dB(L)</Units>
</MicLPSPL>
<MicLTime>13:29:37</MicLTime>
<MicLDate>2025-12-08</MicLDate>
<MicLZCFreq>
<Value>51</Value>
<Units>Hz</Units>
</MicLZCFreq>
<TranTestFreq>7.4 Hz.</TranTestFreq>
<TranTestRatio>4.2</TranTestRatio>
<TranTestResults>Passed</TranTestResults>
<VertTestFreq>7.6 Hz.</VertTestFreq>
<VertTestRatio>3.4</VertTestRatio>
<VertTestResults>Passed</VertTestResults>
<LongTestFreq>7.3 Hz.</LongTestFreq>
<LongTestRatio>3.7</LongTestRatio>
<LongTestResults>Passed</LongTestResults>
<MicLTestFreq>0.0 Hz.</MicLTestFreq>
<MicLTestAmplitude>0 mv</MicLTestAmplitude>
<MicLTestResults>Check</MicLTestResults>
<UsbSummaryChannels>
</UsbSummaryChannels>
<MonitorLog>2025-12-08 13:29:23 - 2025-12-08 13:29:37 &quot;Event Recorded Modem Exit&quot;</MonitorLog>
<HistogramData>
<HistogramDataColumnTitle>
<ColumnTitle> Tran Peak in/s </ColumnTitle>
<ColumnTitle> Tran Freq Hz </ColumnTitle>
<ColumnTitle> Vert Peak in/s </ColumnTitle>
<ColumnTitle> Vert Freq Hz </ColumnTitle>
<ColumnTitle> Long Peak in/s </ColumnTitle>
<ColumnTitle> Long Freq Hz </ColumnTitle>
<ColumnTitle> Geo PVS in/s </ColumnTitle>
<ColumnTitle> MicL Peak psi(L) </ColumnTitle>
<ColumnTitle> MicL Peak dB(L) </ColumnTitle>
<ColumnTitle> MicL Freq Hz </ColumnTitle>
</HistogramDataColumnTitle>
<HistogramDataIntervals>
<Time>2025-12-08 13:29:37</Time>
<Row>
<Cell>1.280</Cell><Cell>15.5</Cell><Cell>2.615</Cell><Cell>64</Cell><Cell>1.120</Cell><Cell>17.7</Cell><Cell>2.644</Cell><Cell>0.001</Cell><Cell>107.0</Cell><Cell>51</Cell></Row>
</HistogramDataIntervals>
</HistogramData>
<HistogramDataUsbChannels>
</HistogramDataUsbChannels>
</Event>
Binary file not shown.
+116
View File
@@ -0,0 +1,116 @@
<?xml version="1.0" encoding="UTF-8"?>
<Event>
<FileVersion>8.0</FileVersion>
<EventType>Full Histogram</EventType>
<SerialNumber>BE18190</SerialNumber>
<Version>V 10.72-8.17 MiniMate Plus</Version>
<FileName>T190LD5Q.LD0H</FileName>
<HistogramStartTime>11:00:49</HistogramStartTime>
<HistogramStartDate>2025-12-09</HistogramStartDate>
<HistogramStopTime>11:00:59</HistogramStopTime>
<HistogramStopDate>2025-12-09</HistogramStopDate>
<Channels>
<Channel>Tran</Channel>
<Channel>Vert</Channel>
<Channel>Long</Channel>
<Channel>MicL</Channel>
</Channels>
<NumberofIntervals>1.00</NumberofIntervals>
<IntervalSize>1 minute</IntervalSize>
<SampleRate>1024 sps</SampleRate>
<BatteryLevel>6.9 Volts</BatteryLevel>
<Calibration>June 13, 2025 by Instantel</Calibration>
<Units>in/s and dB(L)</Units>
<Project>I-80-North Fork-Area 3-462Richardsvilel</Project>
<Client>Fay Company</Client>
<UserName>Terra-Mechanics Inc.- Harrison</UserName>
<SeisLoc>Loc #8 - Area 3- 462 Richardsville Road</SeisLoc>
<GeoRange>
<Value>10.000</Value>
<Units>in/s</Units>
</GeoRange>
<TranPPV>
<Value>2.140</Value>
<Units>in/s</Units>
</TranPPV>
<VertPPV>
<Value>OORANGE</Value>
<Units>in/s</Units>
</VertPPV>
<LongPPV>
<Value>2.830</Value>
<Units>in/s</Units>
</LongPPV>
<TranZCFreq>
<Value>&gt;100</Value>
<Units>Hz</Units>
</TranZCFreq>
<VertZCFreq>
<Value>85</Value>
<Units>Hz</Units>
</VertZCFreq>
<LongZCFreq>
<Value>34</Value>
<Units>Hz</Units>
</LongZCFreq>
<TranPeakTime>11:00:59</TranPeakTime>
<TranPeakDate>2025-12-09</TranPeakDate>
<VertPeakTime>11:00:59</VertPeakTime>
<VertPeakDate>2025-12-09</VertPeakDate>
<LongPeakTime>11:00:59</LongPeakTime>
<LongPeakDate>2025-12-09</LongPeakDate>
<PeakVectorSum>
<Value>OORANGE</Value>
<Units>in/s</Units>
</PeakVectorSum>
<PeakVectorSumTime>11:00:59</PeakVectorSumTime>
<PeakVectorSumDate>2025-12-09</PeakVectorSumDate>
<Microphone>Linear Weighting</Microphone>
<MicLPSPL>
<Value>106.0</Value>
<Units>dB(L)</Units>
</MicLPSPL>
<MicLTime>11:00:59</MicLTime>
<MicLDate>2025-12-09</MicLDate>
<MicLZCFreq>
<Value>85</Value>
<Units>Hz</Units>
</MicLZCFreq>
<TranTestFreq>7.4 Hz.</TranTestFreq>
<TranTestRatio>4.4</TranTestRatio>
<TranTestResults>Passed</TranTestResults>
<VertTestFreq>7.6 Hz.</VertTestFreq>
<VertTestRatio>3.5</VertTestRatio>
<VertTestResults>Passed</VertTestResults>
<LongTestFreq>7.3 Hz.</LongTestFreq>
<LongTestRatio>3.9</LongTestRatio>
<LongTestResults>Passed</LongTestResults>
<MicLTestFreq>20.5 Hz.</MicLTestFreq>
<MicLTestAmplitude>691 mv</MicLTestAmplitude>
<MicLTestResults>Passed</MicLTestResults>
<UsbSummaryChannels>
</UsbSummaryChannels>
<MonitorLog>2025-12-09 11:00:48 - 2025-12-09 11:00:59 &quot;Event Recorded Modem Exit&quot;</MonitorLog>
<HistogramData>
<HistogramDataColumnTitle>
<ColumnTitle> Tran Peak in/s </ColumnTitle>
<ColumnTitle> Tran Freq Hz </ColumnTitle>
<ColumnTitle> Vert Peak in/s </ColumnTitle>
<ColumnTitle> Vert Freq Hz </ColumnTitle>
<ColumnTitle> Long Peak in/s </ColumnTitle>
<ColumnTitle> Long Freq Hz </ColumnTitle>
<ColumnTitle> Geo PVS in/s </ColumnTitle>
<ColumnTitle> MicL Peak psi(L) </ColumnTitle>
<ColumnTitle> MicL Peak dB(L) </ColumnTitle>
<ColumnTitle> MicL Freq Hz </ColumnTitle>
</HistogramDataColumnTitle>
<HistogramDataIntervals>
<Time>2025-12-09 11:00:59</Time>
<Row>
<Cell>2.140</Cell><Cell>&gt;100</Cell><Cell>OORANGE</Cell><Cell>85</Cell><Cell>2.830</Cell><Cell>34</Cell><Cell>OORANGE</Cell><Cell>0.001</Cell><Cell>106.0</Cell><Cell>85</Cell></Row>
</HistogramDataIntervals>
</HistogramData>
<HistogramDataUsbChannels>
</HistogramDataUsbChannels>
</Event>
Binary file not shown.
+116
View File
@@ -0,0 +1,116 @@
<?xml version="1.0" encoding="UTF-8"?>
<Event>
<FileVersion>8.0</FileVersion>
<EventType>Full Histogram</EventType>
<SerialNumber>BE9558</SerialNumber>
<Version>V 10.72-8.17 MiniMate Plus</Version>
<FileName>K558L4KY.440H</FileName>
<HistogramStartTime>17:04:52</HistogramStartTime>
<HistogramStartDate>2025-06-25</HistogramStartDate>
<HistogramStopTime>17:05:39</HistogramStopTime>
<HistogramStopDate>2025-06-25</HistogramStopDate>
<Channels>
<Channel>Tran</Channel>
<Channel>Vert</Channel>
<Channel>Long</Channel>
<Channel>MicL</Channel>
</Channels>
<NumberofIntervals>1.00</NumberofIntervals>
<IntervalSize>5 minutes</IntervalSize>
<SampleRate>1024 sps</SampleRate>
<BatteryLevel>6.3 Volts</BatteryLevel>
<Calibration>June 13, 2025 by Instantel</Calibration>
<Units>in/s and dB(L)</Units>
<Project>Fay - Locks &amp; Dam No3 -Loc 5 Synthomer</Project>
<Client>Fay Company</Client>
<UserName>Terra-Mechanics Inc - Harrison</UserName>
<Seis.Loc>Location #5 Sythomer Plant</Seis.Loc>
<GeoRange>
<Value>10.000</Value>
<Units>in/s</Units>
</GeoRange>
<TranPPV>
<Value>2.315</Value>
<Units>in/s</Units>
</TranPPV>
<VertPPV>
<Value>2.715</Value>
<Units>in/s</Units>
</VertPPV>
<LongPPV>
<Value>5.115</Value>
<Units>in/s</Units>
</LongPPV>
<TranZCFreq>
<Value>10</Value>
<Units>Hz</Units>
</TranZCFreq>
<VertZCFreq>
<Value>85</Value>
<Units>Hz</Units>
</VertZCFreq>
<LongZCFreq>
<Value>19</Value>
<Units>Hz</Units>
</LongZCFreq>
<TranPeakTime>17:05:39</TranPeakTime>
<TranPeakDate>2025-06-25</TranPeakDate>
<VertPeakTime>17:05:39</VertPeakTime>
<VertPeakDate>2025-06-25</VertPeakDate>
<LongPeakTime>17:05:39</LongPeakTime>
<LongPeakDate>2025-06-25</LongPeakDate>
<PeakVectorSum>
<Value>5.559</Value>
<Units>in/s</Units>
</PeakVectorSum>
<PeakVectorSumTime>17:05:39</PeakVectorSumTime>
<PeakVectorSumDate>2025-06-25</PeakVectorSumDate>
<Microphone>Linear Weighting</Microphone>
<MicLPSPL>
<Value>111.8</Value>
<Units>dB(L)</Units>
</MicLPSPL>
<MicLTime>17:05:39</MicLTime>
<MicLDate>2025-06-25</MicLDate>
<MicLZCFreq>
<Value>43</Value>
<Units>Hz</Units>
</MicLZCFreq>
<TranTestFreq>7.7 Hz.</TranTestFreq>
<TranTestRatio>3.9</TranTestRatio>
<TranTestResults>Passed</TranTestResults>
<VertTestFreq>7.5 Hz.</VertTestFreq>
<VertTestRatio>3.8</VertTestRatio>
<VertTestResults>Passed</VertTestResults>
<LongTestFreq>7.5 Hz.</LongTestFreq>
<LongTestRatio>3.7</LongTestRatio>
<LongTestResults>Passed</LongTestResults>
<MicLTestFreq>0.0 Hz.</MicLTestFreq>
<MicLTestAmplitude>0 mv</MicLTestAmplitude>
<MicLTestResults>Check</MicLTestResults>
<UsbSummaryChannels>
</UsbSummaryChannels>
<MonitorLog>2025-06-25 17:04:51 - 2025-06-25 17:05:39 &quot;Event Recorded Modem Exit&quot;</MonitorLog>
<HistogramData>
<HistogramDataColumnTitle>
<ColumnTitle> Tran Peak in/s </ColumnTitle>
<ColumnTitle> Tran Freq Hz </ColumnTitle>
<ColumnTitle> Vert Peak in/s </ColumnTitle>
<ColumnTitle> Vert Freq Hz </ColumnTitle>
<ColumnTitle> Long Peak in/s </ColumnTitle>
<ColumnTitle> Long Freq Hz </ColumnTitle>
<ColumnTitle> Geo PVS in/s </ColumnTitle>
<ColumnTitle> MicL Peak psi(L) </ColumnTitle>
<ColumnTitle> MicL Peak dB(L) </ColumnTitle>
<ColumnTitle> MicL Freq Hz </ColumnTitle>
</HistogramDataColumnTitle>
<HistogramDataIntervals>
<Time>2025-06-25 17:05:39</Time>
<Row>
<Cell>2.315</Cell><Cell>10</Cell><Cell>2.715</Cell><Cell>85</Cell><Cell>5.115</Cell><Cell>19</Cell><Cell>5.559</Cell><Cell>0.001</Cell><Cell>111.8</Cell><Cell>43</Cell></Row>
</HistogramDataIntervals>
</HistogramData>
<HistogramDataUsbChannels>
</HistogramDataUsbChannels>
</Event>
Binary file not shown.
Binary file not shown.
File diff suppressed because it is too large. Load diff
Binary file not shown.
File diff suppressed because it is too large. Load diff
+36 -6
View File
@@ -141,10 +141,12 @@ def test_a_report_fills_in_when_the_record_is_missing():
assert (_dt(ev.timestamp), ev.timestamp_source) == (TRIGGER, "report")
def test_a_histogram_keeps_its_footer_start_for_now():
# Its record (marker fe f5) also holds Blastware's start -- that change is #51.
def test_a_histogram_takes_its_event_records_start():
# #51: its record (marker fe f5) holds Blastware's start; the footer's
# 19:04:50 is a second early.
ev = read_blastware_file(HISTOGRAM)
assert (_dt(ev.timestamp), ev.timestamp_source) == (datetime.datetime(2026, 5, 10, 19, 4, 50), "footer")
assert (_dt(ev.timestamp), ev.timestamp_source) == (datetime.datetime(2026, 5, 10, 19, 4, 51),
"event_record")
def test_the_sidecar_keeps_the_instruments_time_and_says_where_it_came_from():
@@ -173,13 +175,16 @@ def test_an_imported_event_with_only_an_estimate_does_not_overwrite_its_neighbou
from sfm.database import SeismoDb
from sfm.waveform_store import WaveformStore
store, db = WaveformStore(tmp_path / "waveforms"), SeismoDb(tmp_path / "seismo_relay.db")
other = Event(index=0) # a different event at 14:23:43
# A different waveform at 14:23:43. The key is unit + time + type (#51), so
# "its neighbour" is an event of the same type at the same second.
other = Event(index=0)
other.timestamp = Timestamp(raw=b"", flag=0x10, year=2026, unknown_byte=0, month=10, day=26,
hour=14, minute=23, second=43)
other._waveform_key = bytes.fromhex("01110000")
other.record_type = "Waveform"
other.peak_values = PeakValues(tran=0.01, vert=0.02, long=0.03, peak_vector_sum=0.04, micl=None)
db.insert_events([other], serial="BE9441", device_family="series3",
waveform_records={"01110000": {"filename": "K441LTOF.ZJ0H"}})
waveform_records={"01110000": {"filename": "K441LTOF.ZJ0W"}})
broken = bytes(_broken(lambda r, i: r.__setitem__(i + 1, 0x81))) # no validated record
ev, rec = store.save_imported_bw(broken, source_path=Path(ZI0.name))
@@ -189,6 +194,31 @@ def test_an_imported_event_with_only_an_estimate_does_not_overwrite_its_neighbou
waveform_records={ev._waveform_key.hex(): rec}) == (0, 1)
with sqlite3.connect(str(db.db_path)) as c:
assert c.execute("SELECT blastware_filename, peak_vector_sum FROM events").fetchall() == \
[("K441LTOF.ZJ0H", 0.04)]
[("K441LTOF.ZJ0W", 0.04)]
assert (tmp_path / "waveforms" / "BE9441" / "K441LTOF.ZI0").exists() # the data is kept
assert any("not merged" in r.message for r in caplog.records)
def test_an_estimate_beside_a_histogram_at_its_second_is_stored_alongside(tmp_path):
# A waveform and a histogram may share a second (#51): the estimate is its
# own row, and the histogram is untouched.
import sqlite3
from minimateplus.models import Event, PeakValues, Timestamp
from sfm.database import SeismoDb
from sfm.waveform_store import WaveformStore
store, db = WaveformStore(tmp_path / "waveforms"), SeismoDb(tmp_path / "seismo_relay.db")
hist = Event(index=0)
hist.timestamp = Timestamp(raw=b"", flag=0x10, year=2026, unknown_byte=0, month=10, day=26,
hour=14, minute=23, second=43)
hist._waveform_key = bytes.fromhex("01110000")
hist.record_type = "Histogram"
hist.peak_values = PeakValues(tran=0.01, vert=0.02, long=0.03, peak_vector_sum=0.04, micl=None)
db.insert_events([hist], serial="BE9441", device_family="series3",
waveform_records={"01110000": {"filename": "K441LTOF.ZJ0H"}})
broken = bytes(_broken(lambda r, i: r.__setitem__(i + 1, 0x81))) # no validated record
ev, rec = store.save_imported_bw(broken, source_path=Path(ZI0.name))
assert db.insert_events([ev], serial="BE9441", device_family="series3",
waveform_records={ev._waveform_key.hex(): rec}) == (1, 0)
with sqlite3.connect(str(db.db_path)) as c:
rows = c.execute("SELECT record_type, peak_vector_sum FROM events ORDER BY record_type").fetchall()
assert rows[0] == ("Histogram", 0.04) and rows[1][0] == "Waveform"
+157
View File
@@ -365,3 +365,160 @@ def test_a_waveform_with_the_early_record_is_timed_from_its_trigger():
# Blastware: 2019-09-26 11:14:08, record time 4 s (SFM read the stop, 11:14:12)
assert (ts.year, ts.month, ts.day, ts.hour, ts.minute, ts.second) == (2019, 9, 26, 11, 14, 8)
assert ev.timestamp_source in ("event_record", "estimate")
# ── Group A: identity, battery, trigger ─────────────────────────────────────
# The identity block before the setup name is what the live read gets from
# SUB FE (DeviceInfo): serial k-202, firmware k-147, DSP version k-138,
# calibration date k-132 and "by" k-128, manufacturer k-94, model k-72; the
# battery is a uint16 of hundredths of a volt at k-190. Measured against every
# DL2 report 2026-11-03 (serial, version, calibration 69,983 / 69,983).
import datetime as _dt # noqa: E402
_SF = "setup-fields-11-03-26"
def test_the_identity_block_is_read():
# Blastware: BE18189, "V 10.72-8.17 MiniMate Plus",
# "February 20, 2019 by Instantel", "6.8 Volts"
ev = read_blastware_file(_FIX / _SF / "T189HUD6.QE0W")
di = ev.device_info
assert (di.serial, di.firmware_version, di.dsp_version, di.manufacturer, di.model) == (
"BE18189", "S338.17", "10.72", "Instantel", "MiniMate Plus")
assert di.firmware_minor == 17
assert (di.calibration_date, di.calibrated_by) == (_dt.date(2019, 2, 20), "Instantel")
assert abs(ev.battery_volts - 6.8) <= 0.05 + 1e-9
def test_the_battery_is_kept_exact():
# Blastware prints "6.3 Volts" for a stored 6.25: it rounds half up.
assert read_blastware_file(_FIX / _SF / "K558L4KY.440H").battery_volts == 6.25
# (file, Blastware's Trigger as the event record's bitmask, geo level in/s,
# mic level psi or None, mic a trigger source)
@pytest.mark.parametrize("rel,by,geo,mic_psi,mic_src", [
(f"{_SF}/T189HUD6.QE0W", 0x0008, 0.050, 0.0072, True), # MicL, 128.0 dB(L)
(f"{_SF}/T438L713.RY0W", 0x0002, 0.500, 0.0100, True), # Vert, 130.8 dB(L)
(f"{_SF}/M529I6LG.3Y0W", 0x0004, 0.050, 0.005, True), # Long, 0.005 psi(L)
("bw-import-fields-10-29-26/R352HIUI.F40W", 0x0001, 0.400, None, False), # Tran
("decode-checker-10-29-26/T1905KDW.5F0W", 0x0200, None, None, None), # Manual
])
def test_the_trigger_comes_from_the_file(rel, by, geo, mic_psi, mic_src):
ev = read_blastware_file(_FIX / rel)
assert ev.triggered_by == by
if geo is not None:
assert abs(ev.trigger_level_geo - geo) <= 0.0005 + 1e-9
if mic_psi is not None:
assert abs(ev.trigger_level_mic_psi - mic_psi) <= 0.0005 + 1e-9 # psi to 3 places, as printed
if mic_src is not None:
assert bool(ev.trigger_sources & 0x08) == mic_src
assert (ev.record_stop_mode, ev.mic_type) == (0, 2) # Fixed, Linear Weighting
def test_the_h5_carries_the_setup_fields(tmp_path):
import h5py
from sfm import event_hdf5
ev = read_blastware_file(_FIX / _SF / "T189HUD6.QE0W")
event_hdf5.write_event_hdf5(tmp_path / "e.h5", ev, serial="BE18189")
with h5py.File(tmp_path / "e.h5", "r") as f:
a = f.attrs
assert abs(float(a["battery_volts"]) - 6.8) <= 0.05 + 1e-9
assert (int(a["triggered_by"]), int(a["trigger_sources"])) == (0x0008, ev.trigger_sources)
assert abs(float(a["trigger_level_geo_ips"]) - 0.050) <= 0.0005 + 1e-9
assert abs(float(a["trigger_level_mic_psi"]) - ev.trigger_level_mic_psi) < 1e-9
assert (str(a["firmware_version"]), str(a["dsp_version"]), str(a["calibration_date"])) == (
"S338.17", "10.72", "2019-02-20")
# ── Group B: histogram interval detail ──────────────────────────────────────
# Interval size is the setup's uint16 seconds at k - 40 (Series IV [8:10]); the
# stop is the footer's. Each interval keeps its half-periods and its vector sum
# (PVS^2). Frequency = (sample rate / 2) / half-period: 527,915 / 527,915 cells
# at 1024 sps and 1,725 / 1,725 at 2048 (#50: the old fixed 512 halved every
# 2048-sps frequency). Measured 2026-11-03.
from minimateplus.histogram_codec import half_period_to_hz # noqa: E402
_HB = "histogram-intervals-11-03-26"
@pytest.mark.parametrize("rel,sr,freqs,pvs,stop", [
# Blastware: 1 minute; Tran 32, Vert 47, Long 14, MicL 47 Hz; PVS 1.358; stop 12:49:33
("decode-checker-10-29-26/T004JTRF.ME0H", 1024,
{"Tran": 32, "Vert": 47, "Long": 14, "MicL": 47}, 1.358, (2022, 12, 28, 12, 49, 33)),
# Blastware: 1 minute at 2048 sps; Tran 15.5, Vert 64, Long 17.7, MicL 51 Hz; PVS 2.644
(f"{_HB}/T190LD42.T00H", 2048,
{"Tran": 15.5, "Vert": 64, "Long": 17.7, "MicL": 51}, 2.644, (2025, 12, 8, 13, 29, 37)),
])
def test_histogram_interval_detail_comes_from_the_file(rel, sr, freqs, pvs, stop):
ev = read_blastware_file(_FIX / rel)
assert (ev.sample_rate, ev.histogram_interval_sec) == (sr, 60)
for ch, hz in freqs.items():
got = half_period_to_hz(ev.interval_half_periods[ch][0], ev.sample_rate)
d = 1 if isinstance(hz, float) else 0
assert abs(got - hz) <= 0.5 * 10 ** -d + 1e-9, (ch, got, hz)
assert abs(ev.interval_pvs[0] - pvs) <= 0.0005 + 1e-9
t = ev.stop_time
assert (t.year, t.month, t.day, t.hour, t.minute, t.second) == stop
def test_the_h5_carries_the_interval_detail(tmp_path):
import h5py
from sfm import event_hdf5
ev = read_blastware_file(_FIX / _HB / "T190LD42.T00H")
event_hdf5.write_event_hdf5(tmp_path / "e.h5", ev, serial="BE18190")
with h5py.File(tmp_path / "e.h5", "r") as f:
assert int(f.attrs["histogram_interval_sec"]) == 60
assert list(f["intervals/half_period/Vert"][:]) == ev.interval_half_periods["Vert"]
assert abs(float(f["intervals/pvs_ips"][0]) - 2.644) <= 0.0005 + 1e-9
# ── #51: a histogram's start and stop from its own event record ─────────────
# The footer's start runs a second early on 97%. The histogram's event record
# (lead 00 28 05 00, source 04 00, marker fe f5) holds Blastware's start and
# stop: 63,490 / 63,490 DL2 histograms each (2026-11-03).
def test_a_histogram_starts_at_its_event_records_start():
ev = read_blastware_file(_FIX / "decode-checker-10-29-26/T004JTRF.ME0H")
t, s = ev.timestamp, ev.stop_time
# Blastware: start 2022-12-28 12:49:26, stop 12:49:33
assert (t.year, t.month, t.day, t.hour, t.minute, t.second) == (2022, 12, 28, 12, 49, 26)
assert (s.hour, s.minute, s.second) == (12, 49, 33)
assert ev.timestamp_source == "event_record"
def test_a_histogram_without_its_record_falls_back_to_the_footer_and_says_so():
raw = bytearray((_FIX / "decode-checker-10-29-26/T004JTRF.ME0H").read_bytes())
i = raw.find(b"\xfe\xf5")
raw[i] = 0x00 # break the record's marker
ev = decode_blastware_bytes(bytes(raw), name=None)
assert ev.timestamp_source == "footer"
assert ev.timestamp.second == 25 # the footer's start, a second early
assert any("histogram event record" in p for p in ev.decode_problems)
# ── Group D, part 1: time of peak, vector-sum time, peak acceleration ───────
# Measured on 400 DL2 waveforms (2026-11-04):
# time of peak = (peak sample - pre-trigger samples) / sample rate: 1,197 / 1,197
# vector-sum time, the same on sqrt(T^2 + V^2 + L^2): 398 / 399
# peak acceleration = largest |v[i+1] - v[i]| x rate / g, with Blastware's g
# fitted to [386.2236, 386.2240] in/s^2 by every DL2 value: 19,475 / 19,479
@pytest.mark.parametrize("rel,times,pvs_time,accel", [
(f"{_SF}/T189HUD6.QE0W",
{"tran": 0.004, "vert": 0.001, "long": 0.024, "micl": 0.003}, 0.016, (0.027, 0.013, 0.027)),
("decode-checker-10-29-26/R352HIUI.F40W",
{"tran": 0.000, "vert": 0.000, "long": 0.000, "micl": 0.005}, 0.000, (1.617, 0.278, 0.318)),
])
def test_waveform_peak_detail_comes_from_the_samples(rel, times, pvs_time, accel):
pv = read_blastware_file(_FIX / rel).peak_values
for ch, t in times.items():
assert abs(getattr(pv, f"{ch}_time_of_peak") - t) <= 0.0005 + 1e-9, (ch, getattr(pv, f"{ch}_time_of_peak"))
assert abs(pv.pvs_time - pvs_time) <= 0.0005 + 1e-9
for got, want in zip((pv.tran_peak_accel_g, pv.vert_peak_accel_g, pv.long_peak_accel_g), accel):
assert abs(got - want) <= 0.0005 + 1e-9, (got, want)
def test_a_histogram_has_no_waveform_peak_detail():
pv = read_blastware_file(_FIX / "decode-checker-10-29-26/T004JTRF.ME0H").peak_values
assert (pv.tran_time_of_peak, pv.pvs_time, pv.tran_peak_accel_g) == (None, None, None)
+6 -3
View File
@@ -83,9 +83,12 @@ def test_a_waveform_read_under_another_name_keeps_its_time(tmp_path):
datetime.datetime(2026, 10, 26, 14, 23, 42)
def test_a_histogram_keeps_the_binarys_window_start():
assert blastware_filename_time(HISTOGRAM.name) != datetime.datetime(2026, 5, 10, 19, 4, 50)
assert _dt(read_blastware_file(HISTOGRAM).timestamp) == datetime.datetime(2026, 5, 10, 19, 4, 50)
def test_a_histogram_now_agrees_with_its_filename():
# #51: the start comes from the histogram's own event record, which is
# Blastware's -- and so the filename's. The footer's window start (19:04:50)
# was a second early.
assert blastware_filename_time(HISTOGRAM.name) == datetime.datetime(2026, 5, 10, 19, 4, 51)
assert _dt(read_blastware_file(HISTOGRAM).timestamp) == datetime.datetime(2026, 5, 10, 19, 4, 51)
def test_an_import_no_longer_lands_a_waveform_on_its_histogram_twins_row(tmp_path):
+137 -3
View File
@@ -39,7 +39,9 @@ def test_event_type_comes_from_the_bytes():
def test_report_fields_stay_blank():
s = sfm_side((FIX / "T1905KDW.5F0W").read_bytes())
for tag in ("TranZCFreq", "TranPeakAcceleration", "BatteryLevel", "Calibration", "TranTestResults"):
# (BatteryLevel and Calibration are read since 2026-11-03, peak acceleration
# since 2026-11-04: test_the_setup_fields_match_blastware, test_waveform_peak_detail_*)
for tag in ("TranZCFreq", "TranPeakDisplacement", "TranTestResults"):
assert s.values.get(tag) is None
@@ -66,7 +68,7 @@ def test_full_waveform_row_verdicts():
"notes", "samples.Tran", "samples.Vert", "samples.Long"):
assert res[f].verdict == "match", (f, res[f])
assert res["TranZCFreq"].verdict in ("sfm_blank", "no_reference")
assert res["BatteryLevel"].verdict == "sfm_blank"
assert res["BatteryLevel"].verdict == "match" # 6.72 V, printed "6.7 Volts"
assert "FileName" not in res
@@ -95,7 +97,7 @@ def test_zc_frequency_na_and_above_range():
def test_mic_units_pick_the_conversion():
res = _results("T004JTRF.ME0H") # psi(L)
assert res["intervals.MicL Peak dB(L)"].verdict in ("match", "mismatch")
assert res["intervals.Tran Freq Hz"].verdict == "sfm_blank"
assert res["intervals.Tran Freq Hz"].verdict == "match" # read since 2026-11-03
fields = set(_results("R352HFZ7.530H")) # no mic
assert not any(f.startswith(("samples.MicL", "intervals.MicL")) for f in fields)
@@ -221,3 +223,135 @@ def test_blastware_counting_the_monitoring_time_is_accepted():
def test_the_count_carveout_needs_blastwares_own_table_to_agree_with_sfm():
assert _count_case(30, drop_rows=1).verdict == "mismatch"
_GROUP_A = ("SerialNumber", "Version", "Calibration", "BatteryLevel", "Trigger",
"GeoTriggerLevel", "MicTriggerLevel", "RecordStopMode", "Microphone", "Units")
@pytest.mark.parametrize("stem,printed", [
("T189HUD6.QE0W", set(_GROUP_A)),
("T438L713.RY0W", set(_GROUP_A)), # 130.8 dB(L): 0.01 psi at 6895 Pa/psi
("K558L4KY.440H", {"SerialNumber", "Version", "Calibration", "BatteryLevel",
"Microphone", "Units"}), # histogram; battery 6.25 -> "6.3"
])
def test_the_setup_fields_match_blastware(stem, printed):
sf = FIX.parent / "setup-fields-11-03-26"
res = {r.field: r for r in compare(sfm_side((sf / stem).read_bytes()),
parse_xml_report_file(sf / (stem.replace(".", "_", 1) + "_XML.XML")),
CARVEOUTS)}
assert printed <= set(res)
for f in printed:
assert res[f].verdict == "match", (f, res[f])
def test_a_manual_trigger_matches():
res = _results("T1905KDW.5F0W", CARVEOUTS)
assert res["Trigger"].verdict == "match"
def _units_case(sfm_units):
sf = FIX.parent / "setup-fields-11-03-26"
ref = parse_xml_report_file(sf / "T189HUD6_QE0W_XML.XML")
ref.scalars["Units"] = "in/s and psi(L)"
side = sfm_side((sf / "T189HUD6.QE0W").read_bytes())
if sfm_units is not None:
side.values["Units"] = sfm_units
return {r.field: r for r in compare(side, ref, CARVEOUTS)}["Units"]
def test_dB_or_psi_is_blastwares_display_preference():
# Blastware writes its report in its PC's current preference; DL2's reports
# switch fleet-wide in 61 clean runs by write time, and no byte in the file
# tells them apart.
r = _units_case(None)
assert (r.verdict, r.carveout) == ("accepted", "units-is-a-display-preference")
def test_the_units_carveout_still_needs_the_mic():
assert _units_case("in/s").verdict == "mismatch"
def test_a_mic_trigger_level_is_read_in_the_unit_it_is_printed_in():
# K441LA17.IN0W: Units "in/s and psi(L)", yet MicTriggerLevel "125.0 dB(L)".
# The printed value states its own unit; that is the one to compare in.
sf = FIX.parent / "setup-fields-11-03-26"
ref = parse_xml_report_file(sf / "T189HUD6_QE0W_XML.XML") # 128.0 dB(L)
ref.event_units = "in/s and psi(L)"
res = {r.field: r for r in compare(sfm_side((sf / "T189HUD6.QE0W").read_bytes()), ref, CARVEOUTS)}
assert res["MicTriggerLevel"].verdict == "match", res["MicTriggerLevel"]
@pytest.mark.parametrize("path", [FIX / "T004JTRF.ME0H",
FIX.parent / "histogram-intervals-11-03-26" / "T190LD42.T00H"])
def test_histogram_interval_detail_matches_blastware(path):
ref = parse_xml_report_file(path.with_name(path.name.replace(".", "_", 1) + "_XML.XML"))
res = {r.field: r for r in compare(sfm_side(path.read_bytes()), ref, CARVEOUTS)}
for f in ("IntervalSize", "HistogramStopDate", "HistogramStopTime", "intervals.Tran Freq Hz",
"intervals.Vert Freq Hz", "intervals.Long Freq Hz", "intervals.MicL Freq Hz",
"intervals.Geo PVS in/s"):
assert res[f].verdict == "match", (f, res[f])
@pytest.mark.parametrize("halfp,sr,want", [
(0, 1024, "N/A"), (5, 1024, ">100"), (5, 2048, ">200"), (1024, 1024, "<1.0"),
])
def test_blastwares_interval_frequency_words(halfp, sr, want):
# N/A for a half-period of 0, ">100" / ">200" at 5 samples or fewer, "<1.0"
# below 1 Hz -- on ~3.1 M DL2 cells, 2026-11-03.
from minimateplus.decode_check import interval_frequency
assert interval_frequency(halfp, sr) == want
def _pvs_oorange(unclamp=False):
hb = FIX.parent / "histogram-intervals-11-03-26"
ref = parse_xml_report_file(hb / "T190LD5Q_LD0H_XML.XML") # Geo PVS OORANGE, Vert OORANGE
if unclamp:
cols = ref.interval_columns
t, row = ref.intervals[0]
row = list(row)
row[cols.index("Vert Peak in/s")] = "0.500"
ref.intervals[0] = (t, row)
res = {r.field: r for r in compare(sfm_side((hb / "T190LD5Q.LD0H").read_bytes()), ref, CARVEOUTS)}
return res["intervals.Geo PVS in/s"]
def test_an_oorange_interval_vector_sum_is_saturation():
# Blastware prints OORANGE for an interval's vector sum above the range when
# it clamped a channel in that interval: 17 / 17 DL2 cells, SFM's sum
# 10.01 .. 17.33 (= sqrt 3 x 10.005).
r = _pvs_oorange()
assert (r.verdict, r.carveout) == ("accepted", "saturation")
def test_an_oorange_vector_sum_needs_a_clamped_channel_in_that_interval():
assert _pvs_oorange(unclamp=True).verdict == "mismatch"
_PEAK_TIMES = ("TranPeakDate", "TranPeakTime", "VertPeakDate", "VertPeakTime", "LongPeakDate",
"LongPeakTime", "PeakVectorSumDate", "PeakVectorSumTime", "MicLDate", "MicLTime")
@pytest.mark.parametrize("path", [FIX / "T004JTRF.ME0H", # 1 interval
FIX.parent / "footer-11-03-26" / "T003LCYV.JD0H", # 145
FIX.parent / "histogram-decode-11-02-26" / "K440HA3C.JM0H"]) # 8 x 5 s
def test_histogram_times_match_blastware(path):
# #51: an interval's printed time is its end -- start + (n + 1) x interval,
# capped at the stop -- and each peak's date and time are its interval's:
# 2,308,524 / 2,308,524 rows and 2,000 / 2,000 peaks each on a DL2 sample.
ref = parse_xml_report_file(path.with_name(path.name.replace(".", "_", 1) + "_XML.XML"))
res = {r.field: r for r in compare(sfm_side(path.read_bytes()), ref, CARVEOUTS)}
for f in (("HistogramStartDate", "HistogramStartTime", "HistogramStopTime", "intervals.Time")
+ tuple(t for t in _PEAK_TIMES if t in ref.scalars)):
assert res[f].verdict == "match", (f, res[f])
@pytest.mark.parametrize("path", [FIX / "R352HIUI.F40W",
FIX.parent / "setup-fields-11-03-26" / "T189HUD6.QE0W"])
def test_waveform_peak_detail_matches_blastware(path):
ref = parse_xml_report_file(path.with_name(path.name.replace(".", "_", 1) + "_XML.XML"))
res = {r.field: r for r in compare(sfm_side(path.read_bytes()), ref, CARVEOUTS)}
for f in ("TranTimeofPeak", "VertTimeofPeak", "LongTimeofPeak", "MicLTimeofPeak",
"PeakVectorSumTimeSum", "TranPeakAcceleration", "VertPeakAcceleration",
"LongPeakAcceleration"):
assert res[f].verdict == "match", (f, res[f])
+12 -12
View File
@@ -11,7 +11,7 @@ sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
import minimateplus.protocol as mmp_proto # noqa: E402
from device_access_fakes import FakeMiniMateClient # noqa: E402
from sfm.device_access.errors import ( # noqa: E402
ConnectFailed, MalformedReply, NoAnswer, WrongUnit,
ConnectFailed, MalformedReply, NoAnswer, UnitStateUnknown, WrongUnit,
)
from sfm.device_access.models import UnitAddress # noqa: E402
from sfm.device_access.s3 import Series3Adapter # noqa: E402
@@ -51,20 +51,20 @@ def test_status_maps_monitor_status():
assert fake.calls == ["poll", "get_monitor_status"]
def test_settings_maps_the_compliance_config():
s = adapter(FakeMiniMateClient()).settings(TCP, "BE18193")
assert s.record_mode == "Continuous"
assert (s.sample_rate, s.record_time_s, s.histogram_interval_s) == (1024, 3.0, 300)
assert s.geo_trigger_ips == 0.5
assert s.setup_name == "BRIDGE-A"
assert s.notes == {"Project": "Bridge job", "Client": "Acme", "User Name": "BH", "Seis Loc": "Loc 1"}
assert s.detail["record_mode_code"] == 0x01
def test_settings_reads_the_logical_block():
# Phase 5: the settings come from the 1A read assembled into its 2,090 bytes and
# decoded by micromate.setup_fields (tests/test_device_access_s3_settings.py has
# the rest); the fake's block is BE9441's of 2026-10-26.
fake = FakeMiniMateClient()
s = adapter(fake).settings(TCP, "BE18193")
assert (s.record_mode, s.sample_rate, s.setup_name) == ("Histogram", 4096, "Standard Recording Setup.set")
assert fake.calls.index("connect") < fake.calls.index("read_compliance_content")
def test_settings_without_a_compliance_read_is_a_malformed_reply_and_not_retried():
def test_settings_of_a_monitoring_unit_is_refused_and_not_retried():
# One fake only: a retry would ask the factory for a second and fail.
with pytest.raises(MalformedReply, match="settings"):
adapter(FakeMiniMateClient(compliance=None)).settings(TCP, "BE18193")
with pytest.raises(UnitStateUnknown, match="settings"):
adapter(FakeMiniMateClient(monitoring_settings=True)).settings(TCP, "BE18193")
def test_a_cold_unit_over_tcp_gets_one_retry():
+241
View File
@@ -0,0 +1,241 @@
"""Changing a MiniMate's settings by serial (phase 5): preview, one audited send,
read back. The settings block is the 1A read assembled into its 2,090 logical
bytes; the write is push_config_raw's Blastware sequence (68 73 | 71 x n 72 |
82 83 | 69 74 72) with the event index, trigger and waveform blocks sent back as
read. Fixture blocks: BE9441, 2026-10-26."""
from __future__ import annotations
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
import minimateplus.protocol as mp # noqa: E402
from device_access_fakes import FakeMiniMateClient, s3_settings_blocks # noqa: E402
from micromate.setup_fields import encode_setup, field_values # noqa: E402
from minimateplus.client import MiniMateClient # noqa: E402
from minimateplus.protocol import ImageRefused # noqa: E402
from sfm.device_access.errors import ( # noqa: E402
BadRequest, DeviceError, SettingsChanged, UnitStateUnknown,
)
from sfm.device_access.models import UnitAddress # noqa: E402
from sfm.device_access.s3 import Series3Adapter # noqa: E402
TCP = UnitAddress(host="10.0.0.6", tcp_port=12345, port=None, baud=None)
BW_ORDER = ["0x68", "0x73", "0x71", "0x72", "0x82", "0x83", "0x69", "0x74", "0x72"]
class Audit:
def __init__(self):
self.rows = {}
def begin(self, **f):
cid = f"c{len(self.rows) + 1}"
self.rows[cid] = dict(f, outcome="pending")
return cid
def finish(self, cid, **f):
self.rows[cid].update(f)
def adapter(fake):
return Series3Adapter(client_factory=lambda address, **kw: fake)
def change(fake, changes, *, revision=None, dry_run=False, audit=None):
return adapter(fake).change_settings(
TCP, "BE18193", changes=changes, revision=revision, dry_run=dry_run,
audit=audit if audit is not None else Audit(), caller="test", sleep=lambda s: None,
verify_timeout_s=2.0, verify_interval_s=1.0)
def live(fake, changes, audit=None):
rev = change(fake, changes, dry_run=True).plan["revision"]
return change(fake, changes, revision=rev, audit=audit)
def test_s3_settings_read_uses_the_codec():
s = adapter(FakeMiniMateClient()).settings(TCP, "BE18193")
assert (s.record_mode, s.sample_rate, s.histogram_interval_s) == ("Histogram", 4096, 2)
assert (s.record_time_s, s.geo_trigger_ips) == (20.0, 0.04)
assert s.notes["Project"] == "TestUnit-Minimate" and s.notes["Client"] == "Terra-Mechanics"
assert s.detail["record_mode_code"] == 0x03 and s.detail["geo_range"] == "normal"
fields = {d["field"]: d for d in s.detail["editable"]}
assert fields["geo_range"]["value"] == "normal" and fields["note_1"]["label"] == "Project"
def test_s3_settings_read_of_a_monitoring_unit_says_why():
with pytest.raises(UnitStateUnknown, match="stop monitoring first"):
adapter(FakeMiniMateClient(monitoring_settings=True)).settings(TCP, "BE18193")
def test_s3_dry_run_previews_and_sends_nothing():
fake = FakeMiniMateClient()
r = change(fake, {"geo_trigger_ips": 0.05}, dry_run=True)
assert r.outcome == "dry_run" and fake.writes == []
assert r.plan["fields"] == {"geo_trigger_ips": {"label": "Geophone trigger", "old": 0.04, "new": 0.05}}
assert [s["sub"] for s in r.plan["steps"]] == BW_ORDER
assert any("00 00" in w for w in r.plan["warnings"]) and r.plan["blocked"] == []
assert len(r.plan["revision"]) == 16
def test_s3_trigger_change_sends_the_units_own_blocks():
fake = FakeMiniMateClient()
blocks = s3_settings_blocks()
live(fake, {"geo_trigger_ips": 0.05})
event_index, compliance, trigger, waveform = fake.pushed
assert (event_index, trigger, waveform) == (blocks["event_index"], blocks["trigger"], blocks["waveform"])
assert compliance == encode_setup(blocks["compliance"], 3, {"geo_trigger_ips": 0.05})
def test_s3_change_verifies_by_read_back():
fake = FakeMiniMateClient()
r = live(fake, {"geo_trigger_ips": 0.05, "note_4": "Loc 2 - north wall"})
assert (r.outcome, r.verified, r.state_after) == ("sent", "ok", "as asked")
rows = r.detail["snapshot"]["fields"]
assert rows["geo_trigger_ips"] == {"label": "Geophone trigger", "old": 0.04, "new": 0.05, "now": 0.05}
assert rows["note_4"]["now"] == "Loc 2 - north wall"
assert field_values(fake.settings_blocks["compliance"], 3)["geo_trigger_ips"] == 0.05
def test_s3_stale_revision_sends_nothing():
fake = FakeMiniMateClient()
rev = change(fake, {"geo_trigger_ips": 0.05}, dry_run=True).plan["revision"]
fake.settings_blocks["compliance"] = encode_setup(fake.settings_blocks["compliance"], 3, {"job_number": 9})
audit = Audit()
with pytest.raises(SettingsChanged):
change(fake, {"geo_trigger_ips": 0.05}, revision=rev, audit=audit)
assert fake.writes == [] and audit.rows == {}
@pytest.mark.parametrize("dry_run", [True, False])
def test_s3_monitoring_is_refused(dry_run):
fake = FakeMiniMateClient(monitoring_settings=True)
with pytest.raises(UnitStateUnknown) as e:
change(fake, {"geo_trigger_ips": 0.05}, revision="x", dry_run=dry_run)
assert "stop monitoring first" in str(e.value) and "nothing sent" in str(e.value)
assert fake.writes == []
def test_s3_a_value_the_unit_does_not_allow_is_a_bad_request():
with pytest.raises(BadRequest):
change(FakeMiniMateClient(), {"record_time_s": 30.0}, dry_run=True) # 4096 sps: 26 s at most
def test_s3_a_refused_image_is_audited_as_nothing_sent():
audit = Audit()
fake = FakeMiniMateClient(write_error=ImageRefused("write SUB 0x71: not a whole block"))
rev = change(fake, {"geo_trigger_ips": 0.05}, dry_run=True).plan["revision"]
with pytest.raises(DeviceError):
change(fake, {"geo_trigger_ips": 0.05}, revision=rev, audit=audit)
((_, row),) = audit.rows.items()
assert (row["outcome"], row["sent"]) == ("failed", 0)
assert row["error"].startswith("refused before sending")
class _Recorder:
def __init__(self):
self.sent = []
def write(self, data):
self.sent.append(bytes(data))
def read(self, n):
return b""
def test_push_config_raw_precheck_raises_image_refused():
t = _Recorder()
c = MiniMateClient("unused")
c._proto = mp.MiniMateProtocol(t, recv_timeout=0.2)
b = s3_settings_blocks()
with pytest.raises(ImageRefused):
c.push_config_raw(b["event_index"], b["compliance"][:2089], b["trigger"], b["waveform"])
assert t.sent == []
# Final review #1: the revision covers the changes previewed, not only the unit.
def test_s3_a_revision_covers_the_changes_previewed():
fake = FakeMiniMateClient()
rev = change(fake, {"job_number": 7}, dry_run=True).plan["revision"]
with pytest.raises(SettingsChanged):
change(fake, {"geo_trigger_ips": 0.05}, revision=rev)
assert fake.writes == []
# Ruling: the trigger block's byte 5 "differs by unit and session" (#46); the three
# echoed blocks are re-read at send and sent as read, so they are not in the revision.
def test_s3_an_echoed_block_moving_does_not_stale_the_preview():
fake = FakeMiniMateClient()
rev = change(fake, {"geo_trigger_ips": 0.05}, dry_run=True).plan["revision"]
trig = bytearray(fake.settings_blocks["trigger"])
trig[5] = 0x03
fake.settings_blocks["trigger"] = bytes(trig)
assert change(fake, {"geo_trigger_ips": 0.05}, revision=rev).verified == "ok"
assert fake.pushed[2] == bytes(trig) # sent as read at send time
# Final review #4 (spec): the refusal says a stop makes the unit call in.
def test_s3_monitoring_refusal_says_a_stop_calls_in():
with pytest.raises(UnitStateUnknown) as e:
change(FakeMiniMateClient(monitoring_settings=True), {"geo_trigger_ips": 0.05}, dry_run=True)
assert "call in" in str(e.value) and "call-home" in str(e.value)
# Final review #3: the blocks are logical bytes; a block holding a literal
# 10 02 / 10 03 / 10 04 (job number 4098 = 0x1002) must be written intact, and a
# block the write would refuse must show in the preview, not only at Send.
def test_s3_a_bad_echoed_block_is_blocked_in_the_preview():
fake = FakeMiniMateClient()
fake.settings_blocks["event_index"] = fake.settings_blocks["event_index"][:-1]
r = change(fake, {"geo_trigger_ips": 0.05}, dry_run=True)
assert r.plan["blocked"] and r.plan["steps"] == []
from sfm.device_access.errors import ChangeRefused
with pytest.raises(ChangeRefused):
change(fake, {"geo_trigger_ips": 0.05}, revision=r.plan["revision"])
assert fake.writes == []
def _acking():
from minimateplus.framing import build_bw_write_frame # noqa: F401 (frames are parsed below)
from test_minimate_write_frames import _payload
class Acks:
def __init__(self):
self.sent, self._buf = [], b""
def write(self, data):
data = bytes(data)
self.sent.append(data)
sub = _payload(data)[2]
body = bytes([0x00, 0x10, 0xFF - sub, 0x00, 0x00]) + bytes(11)
body += bytes([sum(body) & 0xFF])
self._buf += b"\x10\x02" + body.replace(b"\x10", b"\x10\x10") + b"\x03"
def read(self, n):
out, self._buf = self._buf[:n], self._buf[n:]
return out
return Acks()
def test_push_config_raw_writes_a_logical_block_with_a_literal_escape_byte_intact():
from test_minimate_write_frames import _payload
t = _acking()
c = MiniMateClient("unused")
c._proto = mp.MiniMateProtocol(t, recv_timeout=0.5)
b = s3_settings_blocks()
block = encode_setup(b["compliance"], 3, {"job_number": 4098}) # [40:42] = 10 02
assert block[40:42] == b"\x10\x02"
c.push_config_raw(b["event_index"], block, b["trigger"], b["waveform"])
sent = b"".join(_payload(f)[16:] for f in t.sent if _payload(f)[2] == 0x71)
assert sent == block + b"\x00\x00"
# Bench 2026-11-04 (BE9441): a write sent while the unit's setup menu was open was
# acknowledged and read back -- and then lost when the operator pressed Cancel or
# Save: the menu writes its own copy of the WHOLE block back. The preview says so.
def test_the_preview_warns_that_an_open_setup_menu_loses_the_change():
r = change(FakeMiniMateClient(), {"geo_trigger_ips": 0.05}, dry_run=True)
assert any("setup menu" in w and "lost" in w for w in r.plan["warnings"])
+192
View File
@@ -0,0 +1,192 @@
"""Changing a Micromate's settings by serial (phase 5): preview, one audited send,
read back. The push is micromate.writes.plan_setup_push (THOR's frames) under
the active setup's own name; the unit's schedule is read first, because a
scheduled start loads the setup it names and would undo a change to another."""
from __future__ import annotations
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
import micromate.protocol as mm_proto # noqa: E402
from device_access_fakes import FakeMicromateClient, schedule_record # noqa: E402
from micromate.opcodes import ENABLEABLE_WRITES # noqa: E402
from micromate.setup_fields import field_values # noqa: E402
from sfm.device_access.errors import ( # noqa: E402
BadRequest, ChangeRefused, SettingsChanged, UnitStateUnknown,
)
from sfm.device_access.models import UnitAddress # noqa: E402
from sfm.device_access.s4 import s4_change_settings, s4_settings # noqa: E402
ADDR = UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None)
PUSH_SUBS = [0xDA, 0x68, 0x73, 0x82, 0x83, 0x71, 0x72]
class Audit:
def __init__(self):
self.rows = {}
def begin(self, **f):
cid = f"c{len(self.rows) + 1}"
self.rows[cid] = dict(f, outcome="pending")
return cid
def finish(self, cid, **f):
self.rows[cid].update(f)
def change(fake, changes, *, revision=None, dry_run=False, audit=None):
return s4_change_settings(fake, "UM20147", changes=changes, revision=revision, dry_run=dry_run,
audit=audit if audit is not None else Audit(), address=ADDR,
caller="test", sleep=lambda s: None,
verify_timeout_s=2.0, verify_interval_s=1.0)
def live(fake, changes, audit=None):
rev = change(fake, changes, dry_run=True).plan["revision"]
return change(fake, changes, revision=rev, audit=audit)
def test_setup_push_subs_are_now_enableable():
assert set(PUSH_SUBS) <= ENABLEABLE_WRITES
def test_s4_settings_read_describes_the_editable_fields():
st = s4_settings(FakeMicromateClient(), "UM20147")
fields = {d["field"]: d for d in st.detail["editable"]}
assert fields["geo_trigger_ips"]["value"] == 0.5 and "geo_range" not in fields
def test_s4_dry_run_previews_old_to_new_and_sends_nothing():
fake = FakeMicromateClient()
r = change(fake, {"geo_trigger_ips": 0.3}, dry_run=True)
assert r.outcome == "dry_run"
assert r.plan["fields"] == {"geo_trigger_ips": {"label": "Geophone trigger", "old": 0.5, "new": 0.3}}
assert len(r.plan["revision"]) == 16 and r.plan["blocked"] == []
assert [s["sub"] for s in r.plan["steps"]] == [f"0x{s:02X}" for s in PUSH_SUBS]
assert any("edit buffer" in w for w in r.plan["warnings"])
assert fake.executed == []
def test_s4_trigger_change_sends_the_push_and_verifies():
fake = FakeMicromateClient()
r = live(fake, {"geo_trigger_ips": 0.3})
assert (r.outcome, r.verified, r.state_after) == ("sent", "ok", "as asked")
assert [st.sub for st in fake.executed[0].steps] == PUSH_SUBS
assert field_values(fake.setup, 4)["geo_trigger_ips"] == 0.3
assert r.detail["snapshot"]["fields"]["geo_trigger_ips"] == {
"label": "Geophone trigger", "old": 0.5, "new": 0.3, "now": 0.3}
name_step = fake.executed[0].steps[0]
assert name_step.data.rstrip(b"\x00") == b"TEST1.mmb" # the active setup's own name
def test_s4_stale_revision_sends_nothing():
fake = FakeMicromateClient()
rev = change(fake, {"geo_trigger_ips": 0.3}, dry_run=True).plan["revision"]
fake.setup = FakeMicromateClient(setup=None).setup[:40] + b"\x00\x07" + fake.setup[42:] # job number moved
audit = Audit()
with pytest.raises(SettingsChanged):
change(fake, {"geo_trigger_ips": 0.3}, revision=rev, audit=audit)
assert fake.executed == [] and audit.rows == {}
def test_s4_already_as_asked_is_skipped():
fake = FakeMicromateClient()
r = live(fake, {"geo_trigger_ips": 0.5})
assert r.outcome == "skipped" and fake.executed == []
@pytest.mark.parametrize("dry_run", [True, False])
def test_s4_monitoring_is_refused(dry_run):
fake = FakeMicromateClient(run_states=[0x02])
with pytest.raises(UnitStateUnknown) as e:
change(fake, {"geo_trigger_ips": 0.3}, revision="x", dry_run=dry_run)
assert "stop it first" in str(e.value) and "nothing sent" in str(e.value)
assert fake.executed == []
def test_s4_a_value_the_unit_does_not_allow_is_a_bad_request():
with pytest.raises(BadRequest):
change(FakeMicromateClient(), {"geo_trigger_ips": 12.0}, dry_run=True)
def test_s4_factory_setup_is_refused_live_and_shown_in_preview():
fake = FakeMicromateClient(active_name="factory.MMB")
r = change(fake, {"geo_trigger_ips": 0.3}, dry_run=True)
assert any("factory setup" in b for b in r.plan["blocked"]) and r.plan["steps"] == []
with pytest.raises(ChangeRefused):
change(fake, {"geo_trigger_ips": 0.3}, revision=r.plan["revision"])
assert fake.executed == []
def test_s4_schedule_conflict_blocks():
fake = FakeMicromateClient(schedule_body=schedule_record(14, 0x02, "other.mmb") + bytes(264))
r = change(fake, {"geo_trigger_ips": 0.3}, dry_run=True)
assert any("other.mmb" in b and "07:00" in b for b in r.plan["blocked"])
with pytest.raises(ChangeRefused) as e:
change(fake, {"geo_trigger_ips": 0.3}, revision=r.plan["revision"])
assert "nothing sent" in str(e.value) and fake.executed == []
def test_s4_schedule_on_the_active_setup_warns_only():
fake = FakeMicromateClient(schedule_body=schedule_record(14, 0x02, "test1.MMB")
+ schedule_record(37, 0x04) + bytes(4))
r = change(fake, {"geo_trigger_ips": 0.3}, dry_run=True)
assert r.plan["blocked"] == [] and any("survives" in w and "07:00" in w for w in r.plan["warnings"])
assert live(fake, {"geo_trigger_ips": 0.3}).verified == "ok"
def test_an_unreadable_schedule_refuses():
fake = FakeMicromateClient(schedule_error=mm_proto.ProtocolError("no reply to 0x94"))
r = change(fake, {"geo_trigger_ips": 0.3}, dry_run=True)
assert any("could not read this unit's schedule" in b for b in r.plan["blocked"])
with pytest.raises(ChangeRefused):
change(fake, {"geo_trigger_ips": 0.3}, revision=r.plan["revision"])
assert fake.executed == []
def test_no_schedule_records_is_no_conflict():
r = live(FakeMicromateClient(), {"geo_trigger_ips": 0.3})
assert r.verified == "ok"
def test_s4_a_lost_ack_records_what_the_unit_holds():
fake = FakeMicromateClient(execute_error=mm_proto.TimeoutError("lost"))
r = live(fake, {"geo_trigger_ips": 0.3})
assert (r.outcome, r.sent) == ("failed", True)
snap = r.detail["snapshot"]
assert snap["fields"]["geo_trigger_ips"]["now"] == 0.5 and snap["changed_offsets"] == []
def test_s4_unseen_block_size_is_blocked():
fake = FakeMicromateClient()
fake.prefs = fake.prefs + b"\x00"
r = change(fake, {"geo_trigger_ips": 0.3}, dry_run=True)
assert any("has not seen a block like it" in b for b in r.plan["blocked"])
with pytest.raises(ChangeRefused):
change(fake, {"geo_trigger_ips": 0.3}, revision=r.plan["revision"])
assert fake.executed == []
# Final review #1: the revision covers the changes previewed, not only the unit.
def test_s4_a_revision_covers_the_changes_previewed():
fake = FakeMicromateClient()
rev = change(fake, {"job_number": 7}, dry_run=True).plan["revision"]
with pytest.raises(SettingsChanged):
change(fake, {"geo_trigger_ips": 0.3}, revision=rev)
assert fake.executed == []
# Ruling (final review, declined-to-judge): the blocks a push only echoes are
# re-read at send and sent as read, so they are not part of the revision.
def test_s4_an_echoed_block_moving_does_not_stale_the_preview():
fake = FakeMicromateClient()
rev = change(fake, {"geo_trigger_ips": 0.3}, dry_run=True).plan["revision"]
from micromate.setup_block import with_crc
prefs = bytearray(fake.prefs)
prefs[31] ^= 0x01
fake.prefs = with_crc(bytes(prefs))
assert change(fake, {"geo_trigger_ips": 0.3}, revision=rev).verified == "ok"
+70
View File
@@ -0,0 +1,70 @@
"""DeviceAccess.change_settings (phase 5): the series-independent entry point --
what it refuses before any I/O, and that it dispatches a change (never retried)."""
from __future__ import annotations
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from device_access_fakes import FakeMiniMateClient, FakeMicromateClient # noqa: E402
from sfm.device_access.access import DeviceAccess # noqa: E402
from sfm.device_access.errors import BadRequest, NotSupported # noqa: E402
from sfm.device_access.models import UnitAddress # noqa: E402
ADDR = UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None)
class Audit:
def __init__(self):
self.rows = {}
def begin(self, **f):
cid = f"c{len(self.rows) + 1}"
self.rows[cid] = dict(f, outcome="pending")
return cid
def finish(self, cid, **f):
self.rows[cid].update(f)
def _never(*a, **kw):
raise AssertionError("no connection may be opened")
def _access(s3=_never, s4=_never, audit="default"):
return DeviceAccess(s3_client_factory=s3, s4_client_factory=s4, start_reaper=False,
audit=Audit() if audit == "default" else audit, sleep=lambda s: None)
def test_live_change_without_revision_is_refused_before_io():
with pytest.raises(BadRequest, match="preview first"):
_access().change_settings(ADDR, "UM20147", changes={"job_number": 7}, revision=None)
@pytest.mark.parametrize("changes", [{}, None, "job_number=7"])
def test_empty_changes_is_a_bad_request(changes):
with pytest.raises(BadRequest):
_access().change_settings(ADDR, "BE18193", changes=changes, revision="r", dry_run=True)
def test_a_live_change_without_an_audit_log_is_refused():
with pytest.raises(NotSupported, match="audit"):
_access(audit=None).change_settings(ADDR, "BE18193", changes={"job_number": 7}, revision="r")
def test_change_settings_dispatches_by_series_with_change_true(monkeypatch):
access = _access(s3=lambda a, **kw: FakeMiniMateClient(), s4=lambda a, **kw: FakeMicromateClient())
seen = []
real = access._dispatch
def spy(address, serial, s3_op, s4_op, *, change=False):
seen.append((serial, change))
return real(address, serial, s3_op, s4_op, change=change)
monkeypatch.setattr(access, "_dispatch", spy)
r3 = access.change_settings(ADDR, "be18193", changes={"job_number": 7}, revision=None, dry_run=True)
r4 = access.change_settings(ADDR, "UM20147", changes={"job_number": 7}, revision=None, dry_run=True)
assert (r3.series, r4.series) == (3, 4) and r3.outcome == r4.outcome == "dry_run"
assert seen == [("BE18193", True), ("UM20147", True)]
+49 -6
View File
@@ -426,11 +426,12 @@ def test_the_units_range_reaches_the_store(tmp_path):
assert store.geo_range == 1
# Review finding (2026-10-29): a histogram's row is stored at its file's time,
# a second before the unit's 0C time on most histograms (#51) -- K441LTOK.QZ0
# decodes to 16:06:34, its 0C says 16:06:35 -- so a pre-check on the 0C time
# alone missed it, and a live download overwrote the watcher's row and sidecar.
# The Blastware name encodes the event's own second and does not miss.
# Review finding (2026-10-29): a histogram's row was stored at its file's time,
# a second before the unit's 0C time (#51) -- K441LTOK.QZ0 decoded to 16:06:34,
# its 0C says 16:06:35 -- so a pre-check on the 0C time alone missed it, and a
# live download overwrote the watcher's row and sidecar. Since #51 (dev,
# 2026-11-03) the file decodes the event's own second, so the time matches too;
# the Blastware name, which encodes that second, stays as the second guard.
@pytest.mark.parametrize("stored_as", ["K441LTOK.QZ0", "K441LTOK.QZ0H"]) # direct / call-in name
def test_a_live_histogram_the_watcher_already_stored_writes_nothing(sdm, stored_as):
@@ -442,7 +443,7 @@ def test_a_live_histogram_the_watcher_already_stored_writes_nothing(sdm, stored_
db.insert_events([ev], serial="BE9441", waveform_records={ev._waveform_key.hex(): rec},
device_family="series3") # as the import route (server.py) does
[row0] = db.query_events(serial="BE9441")
assert row0["timestamp"] != "2026-10-26T16:06:35" # the case: the row sits a second off
assert row0["timestamp"] == "2026-10-26T16:06:35" # #51: the event's own second
assert row0["blastware_filename"] == stored_as
out = persist_download(_hist_download("K441LTOK.QZ0", "01110000",
datetime.datetime(2026, 10, 26, 16, 6, 35)), store=store, db=db)
@@ -498,3 +499,45 @@ def test_a_letterless_stored_name_still_matches_a_lettered_download(sdm):
store, db = sdm
_stored_as(store, db, "K441LTOK.QZ0")
assert db.find_event_by_blastware_name("BE9441", "K441LTOK.QZ0H")["blastware_filename"] == "K441LTOK.QZ0"
# #51 (dev, 2026-11-03): a waveform and a histogram recorded in the same second
# are two events (UNIQUE(serial, timestamp, record_type)). A live download of one
# must not be skipped because its twin is stored -- not by the time, and not by a
# letterless Blastware name both twins share. An untyped row at that second still
# counts as stored (conservatively: it may be this event).
def _stored_twin(store, db, name, record_type):
ev, rec = store.save_imported_bw((HIST_FIX / "K441LTOK.QZ0").read_bytes(),
source_path=Path(name), serial_hint=None,
bw_report_text=(HIST_FIX / "K441LTOK_QZ0_ASCII.TXT").read_bytes())
ev.record_type = record_type
db.insert_events([ev], serial="BE9441", waveform_records={ev._waveform_key.hex(): rec},
device_family="series3")
@pytest.mark.parametrize("twin_name", ["K441LTOK.QZ0W", "K441LTOK.QZ0"]) # call-in / direct name
def test_a_live_histogram_is_stored_beside_its_same_second_waveform_twin(sdm, twin_name):
store, db = sdm
_stored_twin(store, db, twin_name, "Waveform")
dl = _hist_download("K441LTOK.QZ0", "01110000", datetime.datetime(2026, 10, 26, 16, 6, 35))
dl.filename = "K441LTOK.QZ0H" # a live download carries the letter (s3.py: with_type_letter)
out = persist_download(dl, store=store, db=db)
assert out.inserted is True
assert sorted(r["record_type"] for r in db.query_events(serial="BE9441")) == ["Histogram", "Waveform"]
def test_an_untyped_row_at_that_second_still_counts_as_stored(sdm):
store, db = sdm
_stored_twin(store, db, "K441LTOK.QZ0", None)
out = persist_download(_hist_download("K441LTOK.QZ0", "01110000",
datetime.datetime(2026, 10, 26, 16, 6, 35)), store=store, db=db)
assert out.inserted is False and out.detail["already_stored"] is True
def test_the_name_lookup_can_be_held_to_a_record_type(sdm):
store, db = sdm
_stored_twin(store, db, "K441LTOK.QZ0", "Waveform")
assert db.find_event_by_blastware_name("BE9441", "K441LTOK.QZ0H", record_type="Histogram") is None
assert db.find_event_by_blastware_name("BE9441", "K441LTOK.QZ0", record_type="waveform") is not None
assert db.find_event_by_blastware_name("BE9441", "K441LTOK.QZ0") is not None
+123
View File
@@ -0,0 +1,123 @@
"""An event is identified by unit + time + type (#51).
The events table was unique on (serial, timestamp): one event per unit per
second. A unit records a waveform and a histogram in the same second
legitimately -- 209 times in prod's 2026-09-30 store once histograms carry
Blastware's start -- so the key is now (serial, timestamp, record_type).
Agreed with Brian 2026-11-03.
"""
from __future__ import annotations
import datetime
import os
import sqlite3
import sys
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from minimateplus.models import Event, PeakValues, Timestamp # noqa: E402
from sfm.database import SeismoDb # noqa: E402
T = "2026-08-25T10:33:29"
T_EARLY = "2026-08-25T10:33:28"
def _event(when: str, rtype: str, key: str = "0111646a", pvs: float = 0.5) -> Event:
t = datetime.datetime.fromisoformat(when)
ev = Event(index=0)
ev.timestamp = Timestamp(raw=b"", flag=0x10, year=t.year, unknown_byte=0, month=t.month,
day=t.day, hour=t.hour, minute=t.minute, second=t.second)
ev._waveform_key = bytes.fromhex(key)
ev.record_type = rtype
ev.peak_values = PeakValues(tran=0.1, vert=0.2, long=0.3, peak_vector_sum=pvs, micl=None)
return ev
def _store(db: SeismoDb, ev: Event, filename: str) -> tuple:
return db.insert_events([ev], serial="BE12844", device_family="series3",
waveform_records={ev._waveform_key.hex(): {"filename": filename}})
def _rows(db: SeismoDb) -> list:
with sqlite3.connect(str(db.db_path)) as c:
c.row_factory = sqlite3.Row
return [dict(r) for r in c.execute(
"SELECT * FROM events ORDER BY timestamp, record_type")]
def _key_sql(db: SeismoDb) -> str:
with sqlite3.connect(str(db.db_path)) as c:
return c.execute("SELECT sql FROM sqlite_master WHERE type='table' AND name='events'"
).fetchone()[0]
def test_a_waveform_and_a_histogram_can_share_a_second(tmp_path):
db = SeismoDb(tmp_path / "seismo_relay.db")
assert _store(db, _event(T, "Waveform"), "N844LQHB.ZT0W") == (1, 0)
assert _store(db, _event(T, "Histogram", key="0111700a"), "N844LQHB.ZT0H") == (1, 0)
assert [(r["timestamp"], r["record_type"]) for r in _rows(db)] == [
(T, "Histogram"), (T, "Waveform")]
def test_the_same_event_twice_is_still_one_row(tmp_path):
db = SeismoDb(tmp_path / "seismo_relay.db")
_store(db, _event(T, "Histogram"), "N844LQHB.ZT0H")
assert _store(db, _event(T, "Histogram", pvs=0.8), "N844LQHB.ZT0H") == (0, 1)
(row,) = _rows(db)
assert row["peak_vector_sum"] == 0.8 # the upsert refreshed it
def test_a_histogram_moves_onto_its_waveforms_second(tmp_path):
# What the release backfill does: the histogram was stored a second early;
# its corrected start is the waveform's second. The row moves in place.
db = SeismoDb(tmp_path / "seismo_relay.db")
_store(db, _event(T, "Waveform"), "N844LQHB.ZT0W")
_store(db, _event(T_EARLY, "Histogram", key="0111700a"), "N844LQHB.ZS0H")
(before,) = [r for r in _rows(db) if r["record_type"] == "Histogram"]
assert _store(db, _event(T, "Histogram", key="0111700a"), "N844LQHB.ZS0H") == (0, 1)
rows = _rows(db)
assert [(r["timestamp"], r["record_type"]) for r in rows] == [(T, "Histogram"), (T, "Waveform")]
assert [r["id"] for r in rows if r["record_type"] == "Histogram"] == [before["id"]]
def test_a_re_typed_event_is_corrected_in_place(tmp_path):
# Before v0.33.0 the type came from the filename; a re-import with the
# file's own type must correct that row, not add a second one.
db = SeismoDb(tmp_path / "seismo_relay.db")
_store(db, _event(T, "Waveform"), "N844LQHB.ZT0H")
(before,) = _rows(db)
_store(db, _event(T, "Histogram"), "N844LQHB.ZT0H")
(row,) = _rows(db)
assert (row["id"], row["record_type"]) == (before["id"], "Histogram")
def test_an_old_database_is_migrated_keeping_every_row_and_id(tmp_path):
db = SeismoDb(tmp_path / "seismo_relay.db")
_store(db, _event(T, "Waveform"), "N844LQHB.ZT0W")
_store(db, _event(T_EARLY, "Histogram", key="0111700a"), "N844LQHB.ZS0H")
old_rows = _rows(db)
with sqlite3.connect(str(db.db_path)) as c: # put the old key back
sql = _key_sql(db).replace("UNIQUE(serial, timestamp, record_type)",
"UNIQUE(serial, timestamp)")
c.executescript(f"""
ALTER TABLE events RENAME TO events_new_key;
{sql};
INSERT INTO events SELECT * FROM events_new_key;
DROP TABLE events_new_key;
""")
assert "UNIQUE(serial, timestamp)" in _key_sql(db)
db = SeismoDb(tmp_path / "seismo_relay.db") # opening migrates
assert "UNIQUE(serial, timestamp, record_type)" in _key_sql(db)
assert _rows(db) == old_rows
assert _store(db, _event(T, "Histogram", key="0111700b"), "N844LQHC.ZT0H") == (1, 0)
with sqlite3.connect(str(db.db_path)) as c:
names = {r[0] for r in c.execute(
"SELECT name FROM sqlite_master WHERE type='index' AND tbl_name='events'")}
assert {"idx_events_serial", "idx_events_timestamp"} <= names
def test_reopening_keeps_the_new_key(tmp_path):
SeismoDb(tmp_path / "seismo_relay.db")
db = SeismoDb(tmp_path / "seismo_relay.db")
assert "UNIQUE(serial, timestamp, record_type)" in _key_sql(db)
+5 -4
View File
@@ -22,7 +22,7 @@ from minimateplus.models import Event
FIX = Path(__file__).parent / "fixtures"
WAVEFORM = FIX / "fft-oracle-2026-09-14" / "N844LQHB.ZT0W" # footer ts2 = 2026-08-25 10:33:32
HISTOGRAM = FIX / "ts-fix" / "K441LKZU.C30H" # window start 2026-05-10 19:04:50
HISTOGRAM = FIX / "ts-fix" / "K441LKZU.C30H" # start 2026-05-10 19:04:51 (#51)
def _tuple(ts):
@@ -39,9 +39,10 @@ def test_waveform_timestamp_is_exact_trigger_from_binary():
def test_histogram_timestamp_is_window_start_unchanged():
ev = read_blastware_file(HISTOGRAM)
# Histogram event time = the window start (ts1); must NOT get the waveform
# ts2 treatment (that would land ~24 h off).
assert _tuple(ev.timestamp) == (2026, 5, 10, 19, 4, 50), _tuple(ev.timestamp)
# Histogram event time = the window start, from its own event record (#51;
# the footer's ts1 is a second earlier); must NOT get the waveform ts2
# treatment (that would land ~24 h off).
assert _tuple(ev.timestamp) == (2026, 5, 10, 19, 4, 51), _tuple(ev.timestamp)
def test_a_report_does_not_override_the_instruments_event_record():
+7
View File
@@ -695,3 +695,10 @@ def test_third_block_still_rejects_a_mismatched_counter():
+ _mk_multi_block(ivs, ctr=257)
+ _mk_multi_block(ivs, ctr=999)) # counter jumps — not consecutive
assert detect_multi_interval_stride(body) != 12 + 20 * 4
def test_half_period_to_hz_follows_the_sample_rate():
"""#50: (sample rate / 2) / half-period, measured on 1,725 / 1,725 cells at
2048 sps; the old fixed 512 halved them."""
assert half_period_to_hz(6, 2048) == pytest.approx(1024 / 6)
assert half_period_to_hz(6) == pytest.approx(512 / 6) # 1024 sps by default
+9 -7
View File
@@ -33,9 +33,11 @@ def _ready(responses):
return p, t
def test_the_ceiling_is_start_stop_and_call_home():
# Phase 4 (2026-11-02) added the call-home write and its confirm.
assert ENABLEABLE_WRITES == frozenset({0x96, 0x97, 0x7E, 0x7F})
def test_the_ceiling_is_start_stop_call_home_and_the_setup_push():
# Phase 4 (2026-11-02) added the call-home write and its confirm; phase 5
# (2026-11-03) the setup push: name, preferences, trigger, setup, confirms.
assert ENABLEABLE_WRITES == frozenset({0x96, 0x97, 0x7E, 0x7F,
0xDA, 0x68, 0x73, 0x82, 0x83, 0x71, 0x72})
def test_execute_sends_exactly_the_plans_frame_and_returns_the_ack():
@@ -54,10 +56,10 @@ def test_permission_ends_with_the_call():
def test_a_plan_beyond_the_ceiling_is_refused_and_nothing_is_sent():
# 0x71 (the setup-block write) stays above the ceiling until phase 5.
# 0xA8 (delete one event) stays above the ceiling (0x71 joined it in phase 5).
p, t = _ready([])
with pytest.raises(OpcodeRefused, match="ceiling"):
p.execute(WritePlan("setup push", (WriteStep(0x71, 0x0000, bytes(4)),)))
p.execute(WritePlan("delete", (WriteStep(0xA8, 0x0000, bytes(4)),)))
assert t.written == []
@@ -111,7 +113,7 @@ def test_a_duck_typed_plan_is_refused():
def test_a_forged_step_in_a_real_plan_is_refused_at_the_step():
p, t = _ready([])
plan = plan_start_monitoring()
object.__setattr__(plan, "steps", (WriteStep(0x71, 0),)) # subs now reads 0x71 too
object.__setattr__(plan, "steps", (WriteStep(0xA8, 0),)) # subs now reads 0xA8 too
with pytest.raises(OpcodeRefused):
p.execute(plan)
assert t.written == []
@@ -122,7 +124,7 @@ def test_a_forged_step_hidden_behind_a_good_plan_is_refused():
@property
def subs(self):
return frozenset({0x96})
plan = Lying("x", (WriteStep(0x96, 0xFFFF), WriteStep(0x71, 0)))
plan = Lying("x", (WriteStep(0x96, 0xFFFF), WriteStep(0xA8, 0)))
p, t = _ready([ACK_START])
with pytest.raises(OpcodeRefused):
p.execute(plan)
+2 -2
View File
@@ -81,7 +81,7 @@ def test_a_frame_that_is_not_a_request_is_refused_not_sent():
def test_every_protocol_read_sub_is_in_the_read_table():
consts = {k: v for k, v in vars(mm_proto).items() if k.startswith("SUB_")}
assert len(consts) == 19
assert len(consts) == 21 # + 0x48 and 0x94, the file read (phase 5)
assert set(consts.values()) <= set(READ_SUBS)
assert {0x94, 0x48} <= set(READ_SUBS)
@@ -98,7 +98,7 @@ def test_an_unknown_opcode_is_refused_and_nothing_is_written(sub):
assert t.written == []
@pytest.mark.parametrize("sub", [0xEE, 0x71, 0xA8]) # 0x71 (setup write) stays above the ceiling until phase 5
@pytest.mark.parametrize("sub", [0xEE, 0xA8, 0xAA]) # delete and its confirm stay above the ceiling
def test_a_permit_beyond_the_ceiling_is_refused_at_the_wire(sub):
p, t = proto([])
with pytest.raises(OpcodeRefused):
+142
View File
@@ -0,0 +1,142 @@
"""Reading a Micromate's schedule file, read-only (phase 5).
A Micromate's scheduled start loads the setup it names, so a settings change to
another setup would be undone at the next start: SFM reads the schedule to refuse
that case. Ground truth is THOR's 2026-09-24/25 captures of UM12947
(bridges/captures/9-24-26 - micromate2): its read of `schedule.dat` (0x94, then
0x48 pages) and its writes of a two- and a five-entry schedule (0x8E bodies).
"""
from __future__ import annotations
import os
import sys
from pathlib import Path
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from micromate.client import MicromateClient # noqa: E402
from micromate.framing import MicromateFrameParser, unstuff # noqa: E402
from micromate.protocol import MicromateProtocol # noqa: E402
from micromate.schedule import ( # noqa: E402
SCHEDULE_PATH, ScheduleEntry, parse_schedule, schedule_conflicts,
)
from test_micromate_protocol import ScriptedTransport, frame # noqa: E402
from test_minimate_write_frames import _frames # noqa: E402
D = Path(__file__).resolve().parent.parent / "bridges" / "captures" / "9-24-26 - micromate2"
READ_S3 = D / "raw_s3_20260924_191835_read_scheduler.bin"
READ_BW = D / "raw_bw_20260924_191835_read_scheduler.bin"
ACTIONCHECK_BW = D / "raw_bw_20260925_005122_actioncheck.bin"
pytestmark = pytest.mark.skipif(not D.is_dir(), reason="bridges/captures is not on this machine")
def _payloads(path: Path) -> list:
return [unstuff(f[2:-1])[:-1] for f in _frames(path.read_bytes())]
def _written_schedule(path: Path) -> bytes:
"""The schedule body THOR wrote: the 0x8E chunks after the 0x8D that opens
schedule.dat, joined (a long body goes in 1,024-byte pieces)."""
body, current = b"", None
for p in _payloads(path):
if p[2] == 0x8D:
current = p[16:] == SCHEDULE_PATH.encode("ascii")
elif p[2] == 0x8E and current:
body += p[16:]
return body
def _read_replies() -> list:
"""The unit's replies to THOR's schedule read: 0x6B, then three 0xB7 pages."""
fr = MicromateFrameParser().feed(READ_S3.read_bytes())
i = next(k for k, f in enumerate(fr) if f.sub == 0x6B)
return fr[i:i + 4]
def test_the_read_capture_parses():
body = bytes(_read_replies()[2].data)[11:]
assert len(body) == 524
e = parse_schedule(body)
assert [(x.time, x.actions) for x in e] == [("07:30", ("start_with_setup",)), ("19:30", ("call_home",))]
assert len(e[0].setup) == 40 and e[1].setup == ""
assert e[0].day == 3 and e[0].action_bits == 2
def test_the_five_entry_schedule_parses():
e = parse_schedule(_written_schedule(ACTIONCHECK_BW))
assert [(x.time, x.actions, x.setup) for x in e] == [
("07:30", ("start_with_setup",), "TEST1.mmb"),
("08:00", ("stop",), ""),
("08:30", ("self_check",), ""),
("09:00", ("start_with_setup",), "test2.mmb"),
("19:30", ("call_home",), ""),
]
def test_conflicts_are_case_insensitive():
e = parse_schedule(_written_schedule(ACTIONCHECK_BW))
assert [x.setup for x in schedule_conflicts(e, "test1.MMB")] == ["test2.mmb"]
assert [x.setup for x in schedule_conflicts(e, " TEST2.mmb ")] == ["TEST1.mmb"]
def test_no_schedule_records_is_no_conflict():
assert parse_schedule(bytes(524)) == []
assert schedule_conflicts(parse_schedule(bytes(524)), "x.mmb") == []
def test_an_unknown_action_bit_is_named_not_dropped():
rec = bytearray(260)
rec[4], rec[5], rec[6] = 14, 3, 0x01 # 07:00, the setup-less start THOR never sends?
(e,) = parse_schedule(bytes(rec))
assert e.actions == ("unknown(0x01)",) and e.setup == ""
assert schedule_conflicts([e], "a.mmb") == [] # no setup named: nothing to undo the change
def test_read_file_sends_thors_frames_and_stops_at_zeros():
replies = [frame(f.sub, bytes(f.data), flags=f.flags, page=f.page_key) for f in _read_replies()]
t = ScriptedTransport(replies)
body = MicromateProtocol(t, recv_timeout=0.5).read_file(SCHEDULE_PATH)
thor = [f for f in _frames(READ_BW.read_bytes()) if unstuff(f[2:-1])[2] in (0x94, 0x48)]
assert t.written == thor[:4] # 0x94 + path, 0x48 (first page), 0x48, 0x48
assert body == bytes(_read_replies()[2].data)[11:]
class _Proto:
def __init__(self, data: bytes):
self.data = data
def read_active_setup_name(self):
return self.data
def read_event_index(self):
return self.data
def read_trigger_config(self):
return self.data
def read_compliance_config(self):
return self.data
def _client(data: bytes) -> MicromateClient:
c = MicromateClient.__new__(MicromateClient)
c._proto = _Proto(data)
return c
def test_get_active_setup_raw_keeps_spaces():
c = _client(bytes(11) + b" LOC 4 .mmb \x00junk")
assert c.get_active_setup_raw() == " LOC 4 .mmb "
assert c.get_active_setup() == "LOC 4 .mmb"
def test_block_content_getters_strip_the_prefix():
c = _client(bytes(range(11)) + b"content")
assert c.get_prefs_content() == c.get_trigger_content() == c.get_setup_content() == b"content"
def test_schedule_entry_is_a_value():
assert ScheduleEntry(0, "07:00", 3, 2, ("start_with_setup",), "a") == \
ScheduleEntry(0, "07:00", 3, 2, ("start_with_setup",), "a")
+12 -2
View File
@@ -193,12 +193,22 @@ def test_steps_cannot_be_reassigned():
def test_call_home_off_from_an_unobserved_start_value_carries_a_warning():
r = bytearray(_call_home_reads()[0])
r[5] = 0x01 # UM20147 reads 0x01, not THOR's 0x04/0x05
r[5] = 0x03 # a value no unit has been seen holding
plan = plan_call_home_enabled(bytes(r), False)
assert any("unobserved" in w and "0x01 -> 0x00" in w for w in plan.warnings)
assert any("unobserved" in w and "0x03 -> 0x02" in w for w in plan.warnings)
assert plan.describe()["warnings"] and plan.describe()["warnings"] == list(plan.warnings)
@pytest.mark.parametrize("start,enabled", [(0x01, False), (0x00, True)])
def test_um20147s_values_are_observed_since_the_bench(start, enabled):
# Bench 2026-11-03 (UM20147): 0x01 -> 0x00 and 0x00 -> 0x01 both acknowledged, read
# back, and matched in the unit's own menu (and again 2026-11-04).
r = bytearray(_call_home_reads()[0])
r[5] = start
plan = plan_call_home_enabled(bytes(r), enabled)
assert not any("unobserved" in w for w in plan.warnings)
def test_call_home_on_when_already_on_says_it_changes_nothing():
r = next(x for x in _call_home_reads() if x[5] == 0x05)
plan = plan_call_home_enabled(r, True)
+2 -34
View File
@@ -213,40 +213,8 @@ def test_each_read_returns_the_block_blastware_then_wrote(read, sub, size):
assert block[:-2] == want[:-2] if sub == 0x69 else block == want[:-2]
# -- apply_config writes this unit's own trigger block ---------------------------
class StubProto:
"""Serves BE9441's blocks as read on 2026-10-26; records every write."""
def __init__(self):
self.writes = []
def read_event_index(self):
return _image(0x68)[:-2]
def read_compliance_config(self):
return _image(0x71)[:-2]
def read_waveform_data_raw(self):
return _image(0x69)
def read_trigger_config(self):
return _image(0x82)[:-2]
def __getattr__(self, name):
if name.startswith("write_"):
return lambda *a, **k: self.writes.append((name, a))
raise AttributeError(name)
def test_apply_config_writes_the_units_own_trigger_block():
from minimateplus.client import MiniMateClient
c = MiniMateClient(transport=object())
c._proto = StubProto()
c.apply_config() # nothing changed: a round trip
trig = [a[0] for n, a in c._proto.writes if n == "write_trigger_config"]
assert trig == [_image(0x82)[:-2]]
assert trig[0][5] == 0x01 # BE9441's; the March copy had 0x03
# -- the unit's own trigger block is sent back: tests/test_device_access_s3_settings.py
# (test_s3_trigger_change_sends_the_units_own_blocks), phase 5.
def test_a_bad_block_is_refused_before_the_first_write_goes_out():
+2 -27
View File
@@ -96,30 +96,5 @@ def test_a_reply_without_the_settings_block_reads_as_unknown():
(None, None, None, None)
# The write side (review finding, 2026-10-29). _encode_compliance_config patches
# the RAW bytes at offsets measured at 1024 sps (April 2026), where an escape sits
# between the mode and the anchor. At other rates the mode is one byte later, so
# a mode change rewrote the byte in front of it. A payload that would not read
# back as asked is refused before anything is sent.
from minimateplus.client import _encode_compliance_config # noqa: E402
def _block(i):
return _settings_replies()[i].ljust(2126, b"\x00") # a whole block's length
@pytest.mark.parametrize("i, change", [
(0, {"recording_mode": 0}), # 10-25 Continuous / 4096: mode sits at -7, not -8
(1, {"sample_rate": 4096}), # 10-26 Histogram+Continuous / 2048: escaped mode shifts the rate
])
def test_a_change_that_would_not_read_back_is_refused(i, change):
with pytest.raises(ValueError, match="read back"):
_encode_compliance_config(_block(i), **change)
def test_a_change_that_reads_back_as_asked_is_built():
out = _encode_compliance_config(_block(0), record_time=7.0)
cc = _decode(out)
assert (cc.recording_mode, cc.sample_rate, cc.histogram_interval_sec, cc.record_time) == \
(1, 4096, 5, 7.0)
# The write side moved to the shared settings codec in phase 5 (2026-11-03):
# tests/test_setup_fields.py reproduces every Blastware write byte for byte.
+151
View File
@@ -0,0 +1,151 @@
"""A MiniMate's settings read, assembled into the logical 2,090-byte block (phase 5).
Measured 2026-11-03 on BE9441's 10-26 recording (12 reads): unescape each 1A
data frame and take data[11:]; every frame but the last starts with one `00`
that is not content -- drop it. The result is the block Blastware writes back:
the read after each of its two writes equals the image it had just written.
While monitoring, the unit answers with its device-info block instead.
"""
from __future__ import annotations
import os
import sys
from pathlib import Path
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
import minimateplus.protocol as mp # noqa: E402
from minimateplus.framing import S3FrameParser # noqa: E402
from minimateplus.protocol import ( # noqa: E402
COMPLIANCE_CONTENT_LEN, assemble_compliance_content, is_compliance_content,
)
from test_minimate_write_frames import WRITES, _payload # noqa: E402
FIX = Path(__file__).parent / "fixtures" / "minimate-bench-10-26-26-histogram"
def _reads() -> list:
"""Each recorded 1A read as its data frames' `data`, in order (a probe reply,
11 bytes of data, starts each read)."""
reads, cur = [], None
for f in S3FrameParser().feed((FIX / "unit_replies.bin").read_bytes()):
if f.sub != 0xE5:
continue
if len(f.data) == 11:
cur = []
reads.append(cur)
else:
cur.append(bytes(f.data))
return reads
READS = _reads()
IMAGES = [b"".join(_payload(f)[16:] for f in WRITES[k:k + 13] if _payload(f)[2] == 0x71)
for k in (0, 13)]
def test_the_recording_holds_twelve_reads_in_both_patterns():
assert len(READS) == 12
assert sorted({len(r) for r in READS}) == [3, 5] # SFM's 1024+1024+42, Blastware's 4x512+42
def test_reads_assemble_to_2090_bytes():
assert COMPLIANCE_CONTENT_LEN == 2090
assert all(len(assemble_compliance_content(r)) == 2090 for r in READS)
def test_a_read_after_a_blastware_write_equals_the_write():
assert assemble_compliance_content(READS[1]) == IMAGES[0][:2090]
assert assemble_compliance_content(READS[2]) == IMAGES[1][:2090]
def test_a_monitoring_units_answer_is_not_settings():
# reads 3-7 were taken while BE9441 was monitoring: they start 0e 'BE9441'
assert [is_compliance_content(assemble_compliance_content(r)) for r in READS[3:8]] == [False] * 5
assert all(is_compliance_content(assemble_compliance_content(r)) for r in READS[:3] + READS[8:])
def _s3_reply(sub: int, data: bytes) -> bytes:
"""A unit reply on the wire: DLE STX, the payload with every 0x10 doubled, ETX.
(`data` here holds no 02/03/04, so no escape is needed.)"""
body = bytes([0x00, 0x10, sub, 0x00, 0x00]) + data
body += bytes([sum(body) & 0xFF])
return b"\x10\x02" + body.replace(b"\x10", b"\x10\x10") + b"\x03"
class _ProbeAndOneFrame:
"""Answers the probe and frame B, then goes silent: frame C never arrives."""
def __init__(self):
self.sent = []
self._replies = [_s3_reply(0xE5, bytes(11)), _s3_reply(0xE5, bytes(11) + bytes(1025))]
self._buf = b""
def write(self, data):
self.sent.append(bytes(data))
if self._replies:
self._buf += self._replies.pop(0)
def read(self, n):
out, self._buf = self._buf[:n], self._buf[n:]
return out
def test_read_compliance_content_refuses_a_missing_frame():
t = _ProbeAndOneFrame()
proto = mp.MiniMateProtocol(t, recv_timeout=0.2)
with pytest.raises(mp.ProtocolError):
proto.read_compliance_content()
assert len(t.sent) == 3 # probe, B, C -- and no D after C went unanswered
# Bench 2026-11-04 (BE9441, live): frame B of a 1A read came back one byte long,
# ending in a lone 0x10 -- the kept escape of a checksum byte that was itself
# escaped (02 / 03 / 04: about one frame in 85); the parser strips only the byte
# after it. The 12 recorded reads never hit it. The read knows how much it asked
# for, so it takes exactly that; a leftover other than that one 0x10 is kept, and
# the block then fails is_compliance_content.
def test_a_frame_with_an_escaped_checksums_stray_byte_is_trimmed_to_what_was_asked():
sfm_read = READS[8] # SFM's own 1024 + 1024 + 42 pattern
good = assemble_compliance_content(sfm_read, lengths=(1024, 1024, 42))
assert good == assemble_compliance_content(sfm_read) and is_compliance_content(good)
stray = [sfm_read[0] + b"\x10", sfm_read[1], sfm_read[2]]
assert len(assemble_compliance_content(stray)) == 2091 # what the bench saw
assert assemble_compliance_content(stray, lengths=(1024, 1024, 42)) == good
def test_a_leftover_that_is_not_the_stray_escape_is_not_trimmed():
sfm_read = READS[8]
odd = [sfm_read[0] + b"\x55", sfm_read[1], sfm_read[2]]
assert not is_compliance_content(assemble_compliance_content(odd, lengths=(1024, 1024, 42)))
# The same artifact on the waveform-data read a settings write echoes back: it asks
# for 0xCA = 202 bytes; one extra trailing 0x10 is the escaped checksum's DLE.
# (Unfixed, it fails closed: the write's own block check refuses 203 bytes.)
class _Replies:
def __init__(self, data):
self._data = data
self.sent = []
def __call__(self, frame):
self.sent.append(frame)
def _waveform_proto(data_reply: bytes):
from types import SimpleNamespace
p = mp.MiniMateProtocol(object())
p._send = _Replies(None)
replies = [SimpleNamespace(data=bytes(11)), SimpleNamespace(data=bytes(11) + data_reply)]
p._recv_one = lambda expected_sub=None, **kw: replies.pop(0)
return p
def test_the_waveform_read_drops_an_escaped_checksums_stray_byte():
block = (200).to_bytes(2, "big") + bytes(range(198)) + b"\x17\x17" # N = 200, plus its 2 tail bytes
assert _waveform_proto(block).read_waveform_data_raw() == block
assert _waveform_proto(block + b"\x10").read_waveform_data_raw() == block
assert _waveform_proto(block + b"\x55").read_waveform_data_raw() == block + b"\x55" # anything else is kept
+4 -9
View File
@@ -23,7 +23,7 @@ from fastapi import HTTPException # noqa: E402
import sfm.server as srv # noqa: E402
WRITES = {"delete_all_events", "apply_config", "set_call_home_config", "stop_monitoring"}
WRITES = {"delete_all_events", "set_call_home_config", "stop_monitoring"}
ADDR = dict(port=None, baud=38400, host="10.0.0.9", tcp_port=9034)
@@ -56,9 +56,6 @@ class Unit:
def delete_all_events(self):
self._rec("delete_all_events")
def apply_config(self, **kw):
self._rec("apply_config")
def set_call_home_config(self, **kw):
self._rec("set_call_home_config")
@@ -72,8 +69,6 @@ class Cache:
def _call(route, serial):
if route == "config":
return srv.device_config(body=srv.DeviceConfigBody(), serial=serial, **ADDR)
if route == "erase":
return srv.device_events_erase(serial=serial, **ADDR)
if route == "rescue":
@@ -98,7 +93,7 @@ def unit(monkeypatch):
return make
ROUTES = ["config", "erase", "rescue", "call_home"]
ROUTES = ["erase", "rescue", "call_home"] # /device/config is retired (410)
@pytest.mark.parametrize("route", ROUTES)
@@ -131,8 +126,8 @@ def test_guarded_route_proceeds_for_the_named_series3_unit(unit, route):
def test_the_identity_check_reuses_connects_serial_where_there_is_one(unit):
# speed: config and erase already read the serial in connect(); no extra read
for route in ("config", "erase"):
# speed: erase already reads the serial in connect(); no extra read
for route in ("erase",):
u = unit("BE9441")
_call(route, None)
assert "read_serial" not in u.calls
+153
View File
@@ -0,0 +1,153 @@
"""POST /device/settings/change (phase 5), and the legacy config write retired.
Handlers are called directly, every parameter passed, as in
test_server_device_access.py."""
from __future__ import annotations
import json
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
import micromate.protocol as mm_proto # noqa: E402
import sfm.server as srv # noqa: E402
from device_access_fakes import FakeMicromateClient, schedule_record # noqa: E402
from fastapi import HTTPException # noqa: E402
from sfm.device_access.access import DeviceAccess # noqa: E402
TCP = dict(port=None, baud=None, host="10.0.0.5", tcp_port=9034)
class Audit:
def __init__(self):
self.rows = {}
def begin(self, **f):
cid = f"c{len(self.rows) + 1}"
self.rows[cid] = dict(f, outcome="pending")
return cid
def finish(self, cid, **f):
self.rows[cid].update(f)
class Cache:
def __init__(self):
self.dirty = []
def mark_config_dirty(self, key):
self.dirty.append(key)
@pytest.fixture
def unit(monkeypatch):
def make(fake):
access = DeviceAccess(s4_client_factory=lambda a, **kw: fake, start_reaper=False,
audit=Audit(), sleep=lambda s: None)
monkeypatch.setattr(srv, "_device_access_instance", access)
cache = Cache()
monkeypatch.setattr(srv, "get_cache", lambda: cache)
return cache
return make
def _post(changes, *, revision=None, dry_run=False, serial="UM20147"):
return srv.device_settings_change(body=srv.SettingsChangeBody(changes=changes, revision=revision),
serial=serial, dry_run=dry_run, caller="test", **TCP)
def _body(resp):
return json.loads(resp.body)
def test_route_dry_run_returns_fields_and_revision(unit):
cache = unit(FakeMicromateClient())
resp = _post({"geo_trigger_ips": 0.3}, dry_run=True)
body = _body(resp)
assert resp.status_code == 200 and body["outcome"] == "dry_run"
assert body["plan"]["fields"]["geo_trigger_ips"] == {"label": "Geophone trigger", "old": 0.5, "new": 0.3}
assert len(body["plan"]["revision"]) == 16 and cache.dirty == []
def test_route_verified_change_is_200_and_mismatch_409(unit, monkeypatch):
fake = FakeMicromateClient()
cache = unit(fake)
rev = _body(_post({"geo_trigger_ips": 0.3}, dry_run=True))["plan"]["revision"]
resp = _post({"geo_trigger_ips": 0.3}, revision=rev)
assert resp.status_code == 200 and _body(resp)["state_after"] == "as asked"
assert len(cache.dirty) == 1 # a by-host read must not serve stale settings
# a unit that acks but stores something else reads back "differs": 409
fake2 = FakeMicromateClient()
unit(fake2)
rev = _body(_post({"job_number": 7}, dry_run=True))["plan"]["revision"]
real = fake2.protocol.execute
def wrong(plan):
acks = real(plan)
fake2.setup = fake2.setup[:40] + b"\x00\x08" + fake2.setup[42:]
from micromate.setup_block import with_crc
fake2.setup = with_crc(fake2.setup)
return acks
monkeypatch.setattr(fake2.protocol, "execute", wrong)
resp = _post({"job_number": 7}, revision=rev)
assert resp.status_code == 409 and _body(resp)["verified"] == "mismatch"
def test_route_unconfirmed_carries_sent_and_audit_id(unit, monkeypatch):
fake = FakeMicromateClient()
unit(fake)
rev = _body(_post({"geo_trigger_ips": 0.3}, dry_run=True))["plan"]["revision"]
real = fake.protocol.execute
def then_drop(plan):
acks = real(plan)
fake.run_states = [0x03] # it began calling home before the read-back
return acks
monkeypatch.setattr(fake.protocol, "execute", then_drop)
resp = _post({"geo_trigger_ips": 0.3}, revision=rev)
body = _body(resp)
assert body["sent"] == "acknowledged" and body["audit_id"]
@pytest.mark.parametrize("fake_kw, match", [
(dict(schedule_body=schedule_record(14, 0x02, "other.mmb") + bytes(264)), "other.mmb"),
(dict(active_name="factory.MMB"), "factory setup"),
(dict(run_states=[0x02]), "stop it first"),
])
def test_route_refusal_is_409_with_reason(unit, fake_kw, match):
fake = FakeMicromateClient(**fake_kw)
unit(fake)
rev = "0000000000000000"
if 0x02 not in fake.run_states: # a monitoring unit refuses the preview too
rev = _body(_post({"geo_trigger_ips": 0.3}, dry_run=True))["plan"]["revision"]
with pytest.raises(HTTPException) as e:
_post({"geo_trigger_ips": 0.3}, revision=rev)
assert e.value.status_code == 409 and match in str(e.value.detail)
def test_route_stale_preview_is_409(unit):
unit(FakeMicromateClient())
with pytest.raises(HTTPException) as e:
_post({"geo_trigger_ips": 0.3}, revision="0000000000000000")
assert e.value.status_code == 409 and "preview again" in str(e.value.detail)
def test_route_live_without_revision_is_422(unit):
unit(FakeMicromateClient())
with pytest.raises(HTTPException) as e:
_post({"geo_trigger_ips": 0.3})
assert e.value.status_code == 422 and "preview first" in str(e.value.detail)
@pytest.mark.parametrize("route", ["device_config", "device_config_project"])
def test_legacy_config_routes_are_gone(route, monkeypatch):
monkeypatch.setattr(srv, "_build_client", lambda *a, **kw: pytest.fail("no client may be built"))
resp = getattr(srv, route)()
assert resp.status_code == 410 and "/device/settings/change" in _body(resp)["detail"]
def test_settings_change_is_serial_aware():
assert "/device/settings/change" in srv._SERIAL_AWARE_PATHS
assert srv._device_guard("/device/settings/change", {"serial": "UM20147", "host": "h"}) is None
+313
View File
@@ -0,0 +1,313 @@
"""One settings codec for both series (phase 5): the field registry, the limits,
the byte patching, and the read-back verdict.
Ground truth:
* Series 3: Blastware's own compliance writes -- BE11529's nine on 2026-04-20
(bridges/captures/4-20-26) and BE9441's two on 2026-10-26 -- each reproduced
from the block before it with the fields Blastware changed.
* Series 4: the 15 UM20147 / UM12947 keypad fixtures, pairwise.
Limits are the units' own, from Instantel's manuals (Brian, 2026-11-03).
"""
from __future__ import annotations
import glob
import itertools
import os
import re
import struct
import sys
from pathlib import Path
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from micromate import setup_fields as sf # noqa: E402
from micromate.setup_block import crc_ok # noqa: E402
from micromate.setup_fields import ( # noqa: E402
SettingsValueError, check_changes, editable_fields, encode_setup, field_bytes, field_values,
revision, settings_state,
)
from minimateplus.framing import S3FrameParser # noqa: E402
from minimateplus.protocol import assemble_compliance_content, is_compliance_content # noqa: E402
from test_minimate_write_frames import WRITES, _frames, _payload # noqa: E402
ROOT = Path(__file__).resolve().parent.parent
APRIL = ROOT / "bridges" / "captures" / "4-20-26"
S4_FIX = sorted(glob.glob(str(ROOT / "tests" / "fixtures" / "micromate-setup" / "*.bin")))
TEN26 = ROOT / "tests" / "fixtures" / "minimate-bench-10-26-26-histogram"
def _s4(path) -> bytes:
b = Path(path).read_bytes()
return b[-2092:] if len(b) > 2092 else b
def _image(frames) -> bytes:
return b"".join(_payload(f)[16:] for f in frames if _payload(f)[2] == 0x71)
def _reads(replies: bytes) -> list:
"""Each 1A read in a reply stream, assembled (a probe reply starts each)."""
reads, cur = [], None
for f in S3FrameParser().feed(replies):
if f.sub != 0xE5:
continue
if len(f.data) == 11:
cur = []
reads.append(cur)
elif cur is not None:
cur.append(bytes(f.data))
return [assemble_compliance_content(r) for r in reads if r]
def _april_pairs() -> list:
"""(name, before, after) for BE11529's April writes, in time order."""
if not APRIL.is_dir():
return []
files = sorted(glob.glob(str(APRIL / "**" / "raw_bw_*.bin"), recursive=True),
key=lambda p: re.search(r"_(\d{6})_", os.path.basename(p)).group(1))
imgs = [(os.path.basename(p), _image(_frames(Path(p).read_bytes()))) for p in files]
imgs = [(n, i) for n, i in imgs if len(i) >= 2092]
pairs = []
first_name, first_img = imgs[0]
s3 = Path(str(Path(files[0]).parent / first_name.replace("raw_bw_", "raw_s3_")))
whole = [r for r in _reads(s3.read_bytes())] if s3.exists() else []
whole = [r for r in whole if is_compliance_content(r)]
if whole: # the read Blastware took before its first write
pairs.append((first_name, whole[0], first_img))
for (_, a), (n, b) in zip(imgs, imgs[1:]):
pairs.append((n, a, b))
return pairs
def _ten26_pairs() -> list:
reads = _reads((TEN26 / "unit_replies.bin").read_bytes())
i0, i1 = _image(WRITES[0:13]), _image(WRITES[13:26])
return [("10-26 send1", reads[0], i0), ("10-26 send2", i0, i1)]
def _changes(before: bytes, after: bytes, series: int) -> dict:
a, b = field_values(before, series), field_values(after, series)
return {f: b[f] for f in b if b[f] != a[f]}
def _with_mic(encoded: bytes, after: bytes) -> bytes:
"""Test-only: BE9441's 16:26 write also turned the mic on ([25] bit 0x08), a
byte v1 does not offer. Copy that one bit from Blastware's image."""
out = bytearray(encoded)
out[25] = (out[25] & ~0x08) | (after[25] & 0x08)
return bytes(out)
def _blastware_mic_rerender(before: bytes, after: bytes) -> bytes:
"""Blastware's write with the unit's own mic trigger levels put back where
Blastware re-rendered them through its dB value. Measured on BE11529's first
write of 2026-04-20 (15:19): the unit read 0.005 and 0.01 psi (channel blocks
3 and 7, `MicL`), Blastware wrote 0.004983 and 0.010058 -- the same levels to
its 0.1 dB. SFM echoes the unit's bytes instead; every other byte must match."""
out = bytearray(after)
for k in range(8):
o = 1708 + 48 * k
if before[o:o + 4] != b"MicL":
continue
a = struct.unpack_from(">f", before, o + 30)[0]
b = struct.unpack_from(">f", after, o + 30)[0]
if a != b and abs(a - b) <= 0.01 * abs(a): # 0.1 dB is 1.2 % in pressure
out[o + 30:o + 34] = before[o + 30:o + 34]
return bytes(out)
S3_PAIRS = _april_pairs() + _ten26_pairs()
@pytest.mark.parametrize("name,before,after", S3_PAIRS, ids=[p[0] for p in S3_PAIRS])
def test_s3_reproduces_every_blastware_write(name, before, after):
out = _with_mic(encode_setup(before[:2090], 3, _changes(before, after, 3)), after)
assert out[:2090] == _blastware_mic_rerender(before, after)[:2090]
def test_the_blastware_writes_are_all_here():
if not APRIL.is_dir():
pytest.skip("bridges/captures is not on this machine")
assert len(S3_PAIRS) >= 10 # 8 April pairs (+1 if its first read is whole) and 2 on 10-26
def _diffs(a: bytes, b: bytes) -> set:
return {i for i in range(2090) if a[i] != b[i]}
def test_s4_fixture_pairs_reproduce():
fb = field_bytes(4)
covered = 0
for pa, pb in itertools.permutations(S4_FIX, 2):
a, b = _s4(pa), _s4(pb)
d = _diffs(a, b)
if not d:
continue
touched = {f for f, bs in fb.items() if bs & d}
if d - set().union(*(fb[f] for f in touched)):
continue # a byte outside the registry moved: not a field-only pair
out = encode_setup(a, 4, {f: field_values(b, 4)[f] for f in touched})
assert out == b, (os.path.basename(pa), os.path.basename(pb))
covered += 1
assert covered >= 10
# ── limits (the units' own) ──────────────────────────────────────────────────
S3_BLOCK = _ten26_pairs()[1][2][:2090] # BE9441, 4096 sps, histogram, Normal range
S4_BLOCK = _s4(ROOT / "tests" / "fixtures" / "micromate-setup" / "um20147_baseline.bin")
def _refused(block, series, changes):
with pytest.raises(SettingsValueError):
check_changes(block, series, changes)
def test_trigger_checked_against_the_new_range():
_refused(S3_BLOCK, 3, {"geo_range": "sensitive", "geo_trigger_ips": 2.0})
assert check_changes(S3_BLOCK, 3, {"geo_range": "sensitive", "geo_trigger_ips": 1.25})
assert check_changes(S3_BLOCK, 3, {"geo_trigger_ips": 2.0})
def test_limits_refuse_outside_values():
for v in (0.004, 10.001, 0.3005):
_refused(S4_BLOCK, 4, {"geo_trigger_ips": v})
for v in (0, 10000):
_refused(S4_BLOCK, 4, {"job_number": v})
for v in (0.9, 90.1):
_refused(S4_BLOCK, 4, {"record_time_s": v})
assert check_changes(S4_BLOCK, 4, {"record_time_s": 90.0})
assert check_changes(S3_BLOCK, 3, {"record_time_s": 26.0}) # 4096 sps
_refused(S3_BLOCK, 3, {"record_time_s": 26.1})
assert check_changes(S3_BLOCK, 3, {"record_mode": "histogram_continuous", "record_time_s": 13.0})
_refused(S3_BLOCK, 3, {"record_mode": "histogram_continuous", "record_time_s": 13.1})
assert check_changes(S3_BLOCK, 3, {"sample_rate": 1024, "record_time_s": 100.0}) # the new rate counts
_refused(S3_BLOCK, 3, {"sample_rate": 8192})
_refused(S3_BLOCK, 3, {"histogram_interval_s": 30})
_refused(S3_BLOCK, 3, {"geo_trigger_ips": "0.3"}) # a number, not a string
_refused(S3_BLOCK, 3, {"job_number": True})
def test_field_not_offered_for_the_series():
with pytest.raises(SettingsValueError, match="Series 4"):
check_changes(S4_BLOCK, 4, {"geo_range": "sensitive"})
_refused(S4_BLOCK, 4, {"no_such_field": 1})
def test_the_alarm_is_writable_since_the_bench():
# Bench 2026-11-04, BE9441: 1.0 -> 1.5 -> 1.0, each acknowledged, read back and
# shown in the unit's own setup menu; the write moved exactly channel +39 of the
# three geophones (the f32 at +38).
assert sf.S3_ALARM_WRITE_MEASURED is True
assert check_changes(S3_BLOCK, 3, {"geo_alarm_ips": 1.5}) == {"geo_alarm_ips": 1.5}
alarm = next(d for d in editable_fields(S3_BLOCK, 3) if d["field"] == "geo_alarm_ips")
assert alarm["readonly"] is False
out = encode_setup(S3_BLOCK, 3, {"geo_alarm_ips": 1.5})
assert [i for i in range(2090) if out[i] != S3_BLOCK[i] and i not in (26, 27)] == [1747, 1795, 1843]
_refused(S4_BLOCK, 4, {"geo_alarm_ips": 1.5}) # still Series 3 only
def _with_unit(block: bytes, unit: bytes) -> bytes:
out = bytearray(block)
for k in range(3):
out[1708 + 48 * k + 34: 1708 + 48 * k + 38] = unit
return bytes(out)
def test_metric_unit_string_refuses_level_writes():
_refused(_with_unit(S4_BLOCK, b"mm\x00\x00"), 4, {"geo_trigger_ips": 0.3})
assert check_changes(_with_unit(S4_BLOCK, b"in.\x00"), 4, {"geo_trigger_ips": 0.3})
assert check_changes(_with_unit(S4_BLOCK, b"in\x00\x00"), 4, {"geo_trigger_ips": 0.3})
assert check_changes(_with_unit(S4_BLOCK, b"mm\x00\x00"), 4, {"job_number": 5}) # not a level
def test_note_edges():
assert check_changes(S4_BLOCK, 4, {"note_1": ""})
assert check_changes(S4_BLOCK, 4, {"note_1": "x" * 41})
_refused(S4_BLOCK, 4, {"note_1": "x" * 42})
_refused(S4_BLOCK, 4, {"note_1": "café"})
_refused(S4_BLOCK, 4, {"note_1": "tab\there"})
out = encode_setup(S4_BLOCK, 4, {"note_1": ""})
assert out[144:186] == bytes(42)
def test_note_labels_are_never_written():
out = encode_setup(S4_BLOCK, 4, {"note_2": "Loc 9 - North wall"})
assert _diffs(S4_BLOCK, out) <= set(range(208, 250))
assert out[186:208] == S4_BLOCK[186:208]
def test_bit_fields_keep_unknown_bits():
b = bytearray(S4_BLOCK)
b[39] = 0x81
assert encode_setup(bytes(b), 4, {"job_number_shown": True})[39] == 0x83
b[39] = 0x83
assert encode_setup(bytes(b), 4, {"job_number_shown": False})[39] == 0x81
def test_s3_fixed_bytes():
b = bytearray(S3_BLOCK)
b[26:28] = b"\x01\x7f"
assert encode_setup(bytes(b), 3, {"job_number": 7})[26:28] == b"\x00\x00"
def test_s4_encode_recomputes_the_crc():
out = encode_setup(S4_BLOCK, 4, {"job_number": 7})
assert crc_ok(out) and out[40:42] == (7).to_bytes(2, "big")
def test_f32_values_read_back_as_asked():
written = encode_setup(S4_BLOCK, 4, {"geo_trigger_ips": 0.3})
assert struct.unpack_from(">f", written, 1708 + 30)[0] != 0.3 # f32: 0.30000001192
assert field_values(written, 4)["geo_trigger_ips"] == 0.3
assert settings_state(S4_BLOCK, written, written, series=4) == "as asked"
def test_settings_state():
written = encode_setup(S4_BLOCK, 4, {"job_number": 7})
assert settings_state(S4_BLOCK, written, S4_BLOCK, series=4) == "unchanged"
other = encode_setup(S4_BLOCK, 4, {"job_number": 8})
assert settings_state(S4_BLOCK, written, other, series=4) == "differs"
bad = bytearray(written)
bad[2091] ^= 0xFF
assert settings_state(S4_BLOCK, written, bytes(bad), series=4) == "differs"
# Series 3: a block that differs from its image only in Blastware's fixed bytes is as asked
before = bytearray(S3_BLOCK)
before[26:28] = b"\x01\x7f"
before = bytes(before)
assert settings_state(before, encode_setup(before, 3, {}), before, series=3) == "as asked"
def test_revision_is_stable_and_content_sensitive():
r = revision([S4_BLOCK, b"name"])
assert r == revision([S4_BLOCK, b"name"]) and len(r) == 16
assert r != revision([S4_BLOCK, b"nams"])
def test_editable_fields_describe_both_series():
s3 = {d["field"]: d for d in editable_fields(S3_BLOCK, 3)}
s4 = {d["field"]: d for d in editable_fields(S4_BLOCK, 4)}
assert {"geo_range", "geo_alarm_ips"} <= set(s3) and not {"geo_range", "geo_alarm_ips"} & set(s4)
assert s3["record_mode"]["value"] == "histogram" and s3["sample_rate"]["value"] == 4096
assert s3["note_1"]["label"] == "Project" and s3["note_1"]["maxlength"] == 41
assert s4["note_1"]["label"] == "Location"
assert s4["record_time_s"]["max"] == 90.0 and s3["record_time_s"]["max"] == 26.0
# Final review #2: the limits hold on the block that would result, not only on the
# fields in the request -- a one-field change must not leave the unit over them.
def test_limits_hold_on_the_resulting_block():
hot = encode_setup(S3_BLOCK, 3, {"geo_trigger_ips": 2.0})
_refused(hot, 3, {"geo_range": "sensitive"}) # trigger 2.0 > 1.25
alarm = bytearray(S3_BLOCK)
struct.pack_into(">f", alarm, 1708 + 38, 2.0)
for k in (1, 2):
struct.pack_into(">f", alarm, 1708 + 48 * k + 38, 2.0)
_refused(bytes(alarm), 3, {"geo_range": "sensitive"}) # alarm 2.0 > 1.25
_refused(S3_BLOCK, 3, {"record_mode": "histogram_continuous"}) # it holds 20 s; combo max 13
slow = encode_setup(S3_BLOCK, 3, {"sample_rate": 1024, "record_time_s": 100.0})
_refused(slow, 3, {"sample_rate": 4096}) # 100 s > 26 at 4096
assert check_changes(S3_BLOCK, 3, {"note_1": "x"}) # nothing limit-related touched
assert check_changes(hot, 3, {"geo_range": "normal"}) # 2.0 <= 10
+71 -6
View File
@@ -29,7 +29,8 @@ pytestmark = pytest.mark.skipif(NODE is None, reason="node is not installed; the
EXPORTS = ["seriesFromSerial", "unitQuery", "deviceUrl", "confirmedSeries", "controlsFor", "eventView", "settingsRows", "perIndexLive", "escapeHtml",
"changeSummary", "downloadSummary", "firmwareLabel", "deviceErrorText", "changeErrorText", "serialPanes",
"callHomeRows"]
"callHomeRows", "settingsFormFields", "settingsChanges",
"settingsPreviewRows", "settingsBlockedText", "settingsResultRows"]
def _block() -> str:
@@ -77,7 +78,8 @@ def test_device_url():
["deviceUrl", ["start", S4]], ["deviceUrl", ["stop", S3]],
["deviceUrl", ["erase", S3]], ["deviceUrl", ["call_home_read", BLANK]],
["deviceUrl", ["config_write", S3]], ["deviceUrl", ["nonsense", S3]],
["deviceUrl", ["download", BLANK, {"event_id": "x"}]], ["deviceUrl", ["hangup", BLANK]])
["deviceUrl", ["download", BLANK, {"event_id": "x"}]], ["deviceUrl", ["hangup", BLANK]],
["deviceUrl", ["settings_change", S4, {"dry_run": "true"}]], ["deviceUrl", ["settings_change", BLANK]])
assert r[0] == {"method": "GET", "path": "/device/info?serial=BE9441&host=h&tcp_port=9034"}
assert r[1] == {"method": "GET", "path": "/device/monitor/status?serial=UM20147&host=h&tcp_port=9034"}
assert r[2] == {"method": "POST", "path": "/device/hangup?host=h&tcp_port=9034"}
@@ -88,9 +90,12 @@ def test_device_url():
assert r[6] == {"method": "POST", "path": "/device/monitor/stop?serial=BE9441&host=h&tcp_port=9034"}
assert r[7] == {"method": "POST", "path": "/device/events/erase?serial=BE9441&host=h&tcp_port=9034"}
assert r[8] == {"method": "GET", "path": "/device/call_home?host=h&tcp_port=9034"}
assert r[9] == {"method": "POST", "path": "/device/config?serial=BE9441&host=h&tcp_port=9034"}
assert "throws" in r[9] # /device/config is retired (phase 5)
assert "throws" in r[10]
assert r[11] is None and r[12] is None
assert r[13] == {"method": "POST", "path": "/device/settings/change?serial=UM20147&host=h&tcp_port=9034"
"&dry_run=true"}
assert r[14] is None # by serial only
def _with(unit, confirmed):
@@ -126,13 +131,62 @@ def test_controls_a_legacy_identify_confirms_without_a_typed_serial():
assert s == 3 and c["diagnostics"] is True and c["startStop"] is False # start/stop needs a serial
def test_controls_config_waits_for_phase_5_and_the_legacy_call_home_form_stays_off():
def test_controls_config_write_is_by_serial_for_both_series():
for unit in (_with(S3, {"serial": "BE9441", "series": 3}), _with(S4, {"serial": "UM20147", "series": 4})):
c = run(["controlsFor", [unit]])[0]
assert c["configWrite"] is False and c["callHomeWrite"] is False
assert c["reasons"] == {"configWrite": "Coming in phase 5 (#46)",
assert c["configWrite"] is True and c["callHomeWrite"] is False
assert c["reasons"] == {"configWrite": "By serial only: Preview, then Send (audited).",
"callHomeWrite": "By serial: use Call-home On / Off (audited). Other call-home "
"fields wait for the THOR round."}
c = run(["controlsFor", [_with(BLANK, {"serial": "BE9441", "series": 3})]])[0]
assert c["configWrite"] is False # by host: the legacy form is read-only
EDITABLE = [
{"field": "record_mode", "label": "Record mode", "kind": "choice", "value": "histogram",
"choices": [{"value": "histogram", "label": "Histogram"}, {"value": "waveform", "label": "Waveform"}]},
{"field": "sample_rate", "label": "Sample rate", "kind": "choice", "value": 1024, "unit": "sps",
"choices": [{"value": 1024, "label": "1024 sps"}, {"value": 4096, "label": "4096 sps"}]},
{"field": "geo_trigger_ips", "label": "Geophone trigger", "kind": "number", "value": 0.3,
"unit": "in/s", "min": 0.005, "max": 10.0, "step": 0.001},
{"field": "geo_alarm_ips", "label": "Geophone alarm", "kind": "number", "value": 1.0, "readonly": True},
{"field": "job_number_shown", "label": "Job number on report", "kind": "bool", "value": False},
{"field": "note_1", "label": "Project", "kind": "text", "value": "Bridge", "maxlength": 41},
]
def test_settings_form_fields_come_from_the_servers_list_in_order():
(f,) = run(["settingsFormFields", [{"detail": {"editable": EDITABLE}}]])
assert [x["field"] for x in f] == [e["field"] for e in EDITABLE]
assert f[2] == EDITABLE[2] and f[3]["readonly"] is True
assert run(["settingsFormFields", [{"detail": {}}]]) == [[]]
def test_settings_changes_are_only_what_differs():
same = {"record_mode": "histogram", "sample_rate": "1024", "geo_trigger_ips": "0.30",
"geo_alarm_ips": "2.0", "job_number_shown": False, "note_1": "Bridge"}
edited = {**same, "sample_rate": "4096", "geo_trigger_ips": "0.25", "job_number_shown": True,
"note_1": "Bridge 2"}
a, b = run(["settingsChanges", [EDITABLE, same]], ["settingsChanges", [EDITABLE, edited]])
assert a == {} # 0.30 == 0.3; the read-only alarm is ignored
assert b == {"sample_rate": 4096, "geo_trigger_ips": 0.25, "job_number_shown": True, "note_1": "Bridge 2"}
PREVIEW = {"outcome": "dry_run", "plan": {
"fields": {"geo_trigger_ips": {"label": "Geophone trigger", "old": 0.5, "new": 0.3},
"note_1": {"label": "Project", "old": "", "new": "Bridge"}},
"blocked": ["this unit's schedule loads other.mmb at 07:00, which would replace this change"],
"revision": "0123456789abcdef"}}
RESULT = {"outcome": "sent", "verified": "ok", "detail": {"snapshot": {"fields": {
"geo_trigger_ips": {"label": "Geophone trigger", "old": 0.5, "new": 0.3, "now": 0.3}}}}}
def test_settings_preview_result_and_blocked_text():
rows, blocked, none, result = run(["settingsPreviewRows", [PREVIEW]], ["settingsBlockedText", [PREVIEW]],
["settingsBlockedText", [RESULT]], ["settingsResultRows", [RESULT]])
assert rows == [["Geophone trigger", 0.5, 0.3], ["Project", "—", "Bridge"]]
assert "other.mmb" in blocked and none == ""
assert result == [["Geophone trigger", 0.5, 0.3, 0.3]]
def test_change_summary():
@@ -334,3 +388,14 @@ def test_call_home_rows_say_why_a_switch_did_not_read():
r = run(["callHomeRows", [{"enabled": None, "dial_string": None, "series": 3,
"detail": {"byte5": "0x6E", "reason": "not readable while monitoring -- stop it first"}}]])
assert r[0][0] == ["Call-home", "not readable while monitoring -- stop it first"]
def test_change_summary_for_settings_says_it_plainly():
base = {"action": "change settings", "audit_id": "cb540970-5e17", "state_before": "unchanged"}
ok, skip, mism = run(
["changeSummary", [{**base, "outcome": "sent", "verified": "ok", "state_after": "as asked"}]],
["changeSummary", [{**base, "outcome": "skipped", "verified": "not_checked", "state_before": "as asked"}]],
["changeSummary", [{**base, "outcome": "failed", "verified": "mismatch", "state_after": "differs"}]])
assert ok == "change settings: confirmed — the unit holds what was sent (audit cb540970)"
assert skip == "change settings: the unit already holds these — nothing sent"
assert "unit reads differs" in mism and "cb540970" in mism
+14
View File
@@ -57,3 +57,17 @@ def test_the_page_scripts_are_served_from_static(name):
def test_a_missing_static_file_is_a_404():
assert _get("/static/nope.js")[0] == 404
def test_the_config_write_is_the_audited_preview_and_send():
# Phase 5: the legacy by-host "Write to Device" is gone; the serial-mode edit
# form's Preview and Send are wired from sfm_webapp.js, not inline handlers.
html = PAGE.read_text()
assert 'id="cfg-write-btn"' not in html
for el in ("cfg-edit", "cfg-preview-btn", "cfg-send-btn", "cfg-preview", "cfg-result"):
tag = re.search(r'<[^>]*id="%s"[^>]*>' % el, html)
assert tag is not None and "onclick" not in tag.group(0), el
js = (PAGE.parent / "static" / "sfm_webapp.js").read_text()
assert "config_write" not in js and "function writeConfig" not in js
assert "getElementById('cfg-preview-btn').addEventListener" in js
assert "getElementById('cfg-send-btn').addEventListener" in js