Brings the branch up to dev (41 commits) before the 1c bench fixes, which
touch code dev changed: the histogram reader (#47/#49, bench finding #2), the
v0.32.0 event-time rules, the Blastware file's setup-block fields (#44/#45),
and the decode checker for verifying stored S3 downloads.
One conflict: the top of the Series-III reference's change table -- both sides
added rows; kept all, in date order, CRLF preserved. CLAUDE.md, README,
blastware_file.py, models.py and database.py merged cleanly. Suite: the known
16 failures only (15 test_bw_ascii_report, test_save_imported_bw_without_report_
works_unchanged, which also fails on dev); 1237 passed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- Spec: the 1c bench pass on BE9441 and UM20147, each on its own modem, and
its 16 findings (a new 'Left open by the 1c bench' section). Ring-path
results, measured: with THOR's watchdog off a call-home reaches THOR when
nobody holds the line (Run 0, via ListenerAchTcp) and is lost when SFM holds
it (Run A: the unit times out and does not retry); with THOR polling, SFM gets
no reply and THOR is undisturbed (A2, step 1). Decision owed before merge:
the Micromate line hold.
- Micromate reference: retracts 'ListenerAchTcp never used' in place (it
accepted tonight's call-home; port 12345); a call-home that rings on another
receiver's connection is lost; a second TCP connection while THOR holds the
line is accepted but silent.
- CLAUDE.md: 1c status, the open decision, THOR's log location.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
C:\THORDATA\Logs\ (Brian). From the 2026-10-29 log: the watchdog reads each
unit's serial every ~15 s; Unit_CommandOutOfRange follows every ReadUnitStatus
for every unit (fleet-wide noise); after a manual THOR disconnect UM20147
answered neither SFM nor THOR's own reconnect ("Mismatch connection found").
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- A matching event that now fails outright is a regression: compare_runs
walks the previous run's matching rows, so a check that collapses to
one error row no longer hides every field it used to match. Counts
moved are taken over the events both runs checked.
- The default baseline is the newest completed run (run.json written) of
the same scope; a 2,000-event sample is no baseline for a full run.
changes.md names the previous run's scope.
- The PVS saturation carve-out now needs Blastware's OORANGE, a channel
Blastware clamped at SFM's ceiling, and SFM's sum within three channels
at the ceiling -- an unclipped Sensitive-range channel read 8x can no
longer let an 8x sum through.
- 'Fields fully matching' needs a match: an always-empty element proves
nothing. Events without a report are a line of their own.
- CLAUDE.md: histogram PVS described correctly; 35 sub-minute histograms
plus 2 one-minute no-mic ones, not '~37 sub-minute'.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
First full run over DL2's 70,042 report-paired events (22 min, --jobs 4):
every expectation the spec set holds. Setup and notes match everywhere;
geophone samples are exact on 6,491/6,524 waveforms across 2016-2026,
the other 33 being the 1.250 in/s range read 8x on SFM's Normal
assumption; every histogram is typed as a waveform without its filename
(#41); the three #53 files are the only waveform time mismatches. New
findings: histogram PVS, mic psi, mic dB on ~1,000 events, ~37
sub-minute histograms, 26 histogram start dates.
The #53 note is corrected in place: those files decode as waveforms with
Blastware's full sample count; only their time falls back to the footer
start. scratch/verify_bw_fields_against_xml.py is retired -- the
checker replaces it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Each run is diffed against the previous one (--compare-to, or the newest
other run in ~/dl2-archive/checker-runs): changes.md lists every
(event, field) that matched before and no longer does, how many now
match, and how each field's counts moved; summary.md leads with the
regression count. --file NAME checks one event and prints its table,
writing no run folder.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
summary.md for Brian: per field, events per verdict, how many fields
fully match, non-matches by event year, carve-out counts. details.json
for Claude: each non-matching (field, verdict) with the attribute values
its failures concentrate in (>= 10% of the failures; concentrated at
>= 95% of compared events) and example events, each with a one-event
re-run command. On a 2,000-event sample the event-type mismatches group
as 'type = Full Histogram, 1815/1815' -- #41, named by the report.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
check_s3_decode.py pairs each Series 3 event file with its _XML.XML
report (deduped by basename -- Sent/ mirrors the root), checks each in a
process pool, and writes results.jsonl.gz and run.json to a run folder
outside the repo. A missing report or any failure is one row for that
event; the run goes on. Partial runs by serial, year, type, field
prefix or random sample.
Timing: --sample 2000 --jobs 4 took 35 s on tmi-dev (~20 min projected
for all 70,042).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
A mismatch becomes 'accepted' only through a written carve-out whose
evidence does not rest on SFM's output. Saturation: Blastware clamps a
clipped channel to the range maximum and prints OORANGE, while the file
holds counts past full scale. SFM's value must sit at the ceiling
(r - 0.0006 .. r * 1.01), so a Sensitive-range event read 8x high on
SFM's Normal assumption stays a mismatch; a vector sum is accepted when
a clipped channel under it is at the ceiling. series_pairs() is now the
one place waveform rows and interval columns are paired.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Every field the report carries (bar its format version and Blastware's
file name), the notes in order, the job number, the channel list, every
waveform sample and every histogram interval column. Numbers match at
Blastware's printed precision, halves rounding away from zero; N/A and
empty text are no_reference; >100 needs SFM's above-range flag; OORANGE
is a mismatch unless a carve-out says otherwise. Waveform rows pair
cells with the channels still running, so channels that end early
(T438HGTZ.B30W) match, and any row-length disagreement is counted.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
decode_blastware_bytes with no filename and no report: the values SFM
produces today in Blastware's field names, its notes, channels and raw
counts, with its Normal-range assumption kept.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The reference for the Series 3 decode checker: scalars and value units,
channels, the job number, the user notes in order under their
operator-edited labels, waveform rows as printed (ragged where channels
end at different lengths) and histogram intervals. Seven real DL2
events as fixtures, each covering a case the comparison must handle.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Eight tasks: the XML report parser, SFM's side from the bytes alone, the
field-by-field comparison, carve-outs (saturation first), the parallel
runner, the summary and grouped detail report, run-to-run changes with a
one-event view, and the first full run checked against what is known.
While pinning the plan's test values on real files: T438HGTZ.B30W, called
"3 samples short" by the setup-field harness, matches Blastware exactly.
Its Tran, Vert and MicL end 3 samples before Long, and Blastware's own
sample table does the same -- its last three rows carry only the Long cell.
The harness compared Tran's length with the table's row count. The spec
now says so, and the plan compares samples row by row by running channel.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The first of four pieces toward SFM producing everything Blastware reports
from the event file alone: compare every field, sample and histogram
interval with DL2's 70,042 _XML.XML reports (2016-2026), report what
matches, what doesn't and what SFM can't produce yet, grouped for
diagnosis, run after run.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
- README roadmap, Ingestion gaps: a bulk importer for event files on disk,
parked -- one of the four ways events should reach SFM.
- CLAUDE.md: the 14,338 ASCII pairs were described as "back to 2018"; they
are all 2025-26 events. Corrected in place. DL2's Sent/ _XML.XML files
are Blastware's full event reports, samples included, for 70,042 events
back to 2016 -- the reference for proving SFM's file-only decode.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
verify_bw_fields_against_xml.py decodes each Blastware event file the way
ingest does, without a report, and compares sample rate, record time,
pre-trigger, sample count, the four notes and the job number with the
event's _XML.XML report -- Blastware's full event report, which DL2 kept
for 70,042 events back to 2016 (ASCII reports exist only for 2025-26).
Every disagreement counts against SFM; there is no carve-out list yet.
The first piece of the decode checker.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Without a paired ASCII report, a Blastware import stored no sample rate,
the record-type byte as its record time (every waveform read "70 s"), a
pre-trigger and sample count read from STRT bytes that are neither, and
blank notes (the reader stopped at the NUL after each label).
- The recording-setup block is found by structure -- 1c 08, the setup
name, NUL -- not by the name "Standard Recording Setup", which 37% of
DL2's files do not use. One match in each of 70,041 archive files.
- Sample rate (uint16 BE, name-42), pre-trigger (f32 BE, name-36) and
record time (f32 BE, name-30). A waveform's sample count is the
decoded count. A histogram gets a sample rate only: Blastware reports
neither a record time nor a pre-trigger for one.
- The setup name and the four user notes by position, as bw_ascii_report
reads them: the labels are operator-editable ("Seis. Loc:",
"Location:", "Project: ").
- STRT now yields only the waveform key.
Verified against Blastware's own _XML.XML event reports for the 70,042
DL2 archive events that have one (2016-2026): sample rate 70,042/70,042,
record time 6,524/6,524, pre-trigger 6,484/6,484, notes 70,042/70,042,
sample count 6,523/6,524 (one waveform the decoder ends 3 samples short;
separate). Events imported with an ASCII report are unchanged -- the
report still overlays.
Not changed: the waveform-time estimate still finds the record time by
the marker; moving it would add a validation constraint for 37% of files
and is to be measured first. The job number is not read yet (2,997
archive events carry one).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Asks the bench SFM for a Micromate's status on a fixed interval (Run B) or
once (Run A), with run_state=true, and logs each answer with its time as JSON
lines: HTTP status, seconds, the raw 0x49 code, and the detail of any refusal
(503 call-home-in-progress / could-not-connect). Read-only on the unit;
refuses :8200.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
GET /device/monitor/status?serial=UM...&run_state=true adds
detail.run_state = {code, name}. For the ring-path bench test: the code
during and after a call-home (0x01 for ~18 s after a stop, inferred to be
call-home attempts; 0x03 = calling home) is what the test watches. Opt-in
because it is one more round trip (~0.65 s on cellular); a plain status read
is unchanged. Series 3 has no 0x49 and ignores it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- micromate reference: the watchdog can check every 5 s, hourly or never
(Brian, operator-reported). The 10-14 "reconnects continuously" describes
that THOR's setting, not fixed behaviour; whether a check holds the line,
and how a call-home reaches THOR with the watchdog off, are unmeasured.
- spec, ring-path test: the old setup ("a unit THOR is not otherwise
watching") would not test the production path, since THOR receives a
call-home on its own connection. Revised: UM20147 as a THOR test unit; Run 0
baseline with the watchdog off; Run A with SFM holding the line; Run A2 and
Run B at the fleet's watchdog setting; after the 1c bench pass.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- The arrow keys reached the legacy per-index waveform route in serial mode,
even with no list loaded (an unlocked MiniMate chain walk + 5A on the same
modem session). perIndexLive() is now the one rule for the per-index
buttons, the chips and the keyboard: live only for a list loaded without a
serial that has events.
- A failed reconnect left the previous unit's confirmation live (badge,
Diagnostics incl. the unguarded blind/slow-drip stops, call-home read).
connectUnit() now drops it before it identifies; only this answer confirms.
- Unit strings reached innerHTML: the Device tab's cards (active_setup, new in
1c) and its compliance/project tables now render as text, and Diagnostics'
error spans go through escapeHtml().
- CLAUDE.md: the ring-path Runs A/B are a merge gate (the spec's prerequisite
to a webapp sending serial), not only a use-time one.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- CLAUDE.md: a 1c entry under Where things stand (serial mode, what follows
the unit's own answer, writes off until phases 4-5, the Node-run page tests)
and the legacy-route guard in the REST API notes, with why the stop tools
are exempt.
- Spec: the 1c build status; the ring-path Runs A/B are still owed before
serial mode is used on a unit that calls home to THOR; which parked 1c items
the page settles (CORS: same origin; the S4 mic is not shown).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Task 3's brief asked for them and they were missed: with a serial, the panel
now shows UnitStatus.device_time and event_count, "—" where null (Series 3
reports both as null). Without a serial the two fields stay hidden.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- Config, with a serial: Read shows the unit's shared UnitSettings (setup,
record mode, sample rate, record time, histogram interval, geo trigger,
notes; — for null) in place of the write form. settingsRows() is in the
device-routing block, Node-tested; the rows are rendered as text, since
setup names and notes come from the unit.
- Write stays off for both series (and without a serial), tooltip
"Coming in phase 5 (#46)"; Call Home write likewise, "Coming in phase 4".
- Call Home read follows controlsFor().callHomeRead; for a confirmed Series 4
the tab says "Not yet available for Series 4".
- Diagnostics: every button follows controlsFor().diagnostics (Task 3), and a
refresh for anything but a confirmed Series-3 unit sends nothing and says
why. Its requests carry the typed serial, so the server guard checks it.
- Without a serial the legacy reads are unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- With a serial, Start / Stop ask first ("Start monitoring on BE9441?"), then
POST once to the audited change -- never retried; both buttons stay off while
it is in flight, so a double click cannot send twice.
- The status bar shows changeSummary() of the ChangeResult, on a 409/502 too
(dry run, already-in-state, confirmed a -> b, or the outcome and read-back);
an error without one shows its detail verbatim; no reply from SFM says the
command may have been sent and where to look, rather than that nothing was.
- Then one status read updates the panel. The legacy 5 s confirm poll is not
used in serial mode; with a blank serial start/stop are unchanged.
- Diagnostics' Stop, which goes the same way in serial mode, shows the same
summary; deviceFetch errors carry it for any non-200 ChangeResult.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- Load events with a serial lists the shared EventRef shape as a table: index,
time, type, PVS and the three peaks (or —), each row with its own Download.
- Download POSTs the row's event_id; SFM checks and stores it. The status bar
says what was stored (or that it already was), and the stored event opens
in the viewer. A refusal shows the server's detail verbatim.
- eventView() (device-routing block, Node-tested) reads both event shapes for
the table, the chips and the peaks bar.
- A list loaded without a serial keeps the chips and the per-index Load /
Save / Download buttons, unchanged; for a serial-loaded list those buttons
are off with a tooltip pointing at the rows.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- A Serial field beside host/port. With one, the Live tabs use the serial-based
endpoints (both series); without, every read behaves as before.
- The series badge, Hang up (Series 4), Diagnostics (Series 3), call-home read and
the disabled config/call-home writes all follow applyControls() <- controlsFor()
on the unit's own /device/info answer; editing the serial, host or port drops
the confirmation. Erase additionally needs a confirmed Series 3.
- Every /device/ request goes through deviceRequest/deviceFetch <- deviceUrl
(a static test enforces it); the legacy per-event routes joined deviceUrl
(event_waveform / event_file, index in the path).
- The status panel and Device tab read both shapes (shared and legacy).
- In serial mode the connect skips the legacy storage_range read (one connection
fewer; a Micromate has no such route). Start/stop without a serial behave as
before; with one, only for a confirmed series.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
One block of sfm_webapp.html (/* <device-routing> */) holds every rule that
decides where a /device/ request goes or whether a series-specific control is
live: seriesFromSerial, unitQuery, deviceUrl, confirmedSeries, controlsFor,
changeSummary, downloadSummary. No DOM, no fetch, so the tests run it in Node.
The safety rules it pins: a control follows the unit's own /device/info answer,
never a typed serial alone, and stops counting when the serial is edited;
Diagnostics only for a confirmed Series 3, Hang up only for Series 4; config and
call-home writes off for both series until phases 4-5. Also a test that the
page's inline scripts parse together (shared global scope).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
0xA2 is CONFIRM ERASE on a MiniMate and ends a call-home on a Micromate, and the
legacy host/port routes had no identity check: only the MiniMate parser's
inability to read a Micromate's replies stood between Diagnostics' Erase and a
Micromate (phase 1c safeguard, agreed with Brian 2026-10-28).
_require_series3(unit_serial, expected) refuses (409, 'nothing sent') unless the
unit's own serial is Series 3 and, when ?serial= names one, that one:
- POST /device/config (+ /config/project) and /device/events/erase: the serial
connect() already reads -- no extra request;
- /device/rescue (when it writes call-home or erases) and POST /device/call_home:
one SUB 0x15 read (new MiniMateClient.read_serial).
Exempt, with the reason in a comment: legacy monitor start/stop, blind stop, slow
drip, spam -- 0x96/0x97 mean the same on both series (measured), and the rescue
tools must reach a unit too wedged to answer.
Tests: each guarded route refuses a unit answering UM20147 and a different BE
unit with no write call, proceeds for the named unit (normalised), reuses
connect()'s serial where it has one; the blind stop builds no client;
read_serial decodes BE9441's recorded 0x15 reply.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
SFM is the whole seismograph module and "SDM" is retired; the codec
library stays pure; lab tools leave the production image and are ported
into sfm/ when they become production tools; the call-in server becomes
SFM's front door; the repo becomes `sfm` after the parity branch merges.
The old section stays in place below the banner as history.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
Review of b5037b0 (measured on 12 recorded SFM compliance reads): the read
keeps three escape bytes from its reply headers, so every real config image is
refused by write_image -- correctly, but only after 68 and 73 had been sent,
with a message saying nothing was. All four blocks are now checked first; the
test feeds the block exactly as SFM's read produces it and asserts no frame is
sent (two went out without the check).
Config push stays unusable on purpose: fixing that read alone would let the
compliance encoder write some fields to the wrong bytes (e.g. 4,096 sps as
4,112) while the image still passes. The rework -- logical read, encoding at
measured offsets with #48, a diff check, N pinned per SUB, an idle check, the
start/stop safeguards on POST /device/config -- is recorded in the spec and on
#46. Start/stop frames are unchanged (verified byte-identical by the review).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Measured against every Blastware request on record: the uploaded Feb-Apr 2026
captures (3,869 frames, 3,869 re-encode exactly) and BE9441's two sends on
2026-10-26 (26 write frames). A write is the standard 16-byte request plus its
data, every 02/03/04/10 escaped, SUM8 checksum; the length field is the data's
length. A config block starts with its own length N and is written as N + 2
bytes: event index (68) and trigger (82) as read plus 02 00 / 00 00 (constant on
15 sends), waveform data (69) and the 2,092-byte compliance image (71) whole.
The compliance image goes in addressed chunks (params[2:4] = address): 512 bytes
tonight (Blastware 10.74), 1,024 in March.
- framing.build_bw_write_frame: uniform escaping, SUM8, length = len(data).
RETRACTED: 'only BW_CMD doubled', the 'DLE-aware checksum', 'offset = data[1]
+ 2' -- fitted to frames still holding their escape bytes ('data 91, offset 90'
was 90 bytes and one escape). It got 7 of every 13 frames in a write wrong.
- protocol.write_image(): unescapes (callers may pass the parser's form), adds
the trailing two bytes to an N-byte block, and REFUSES anything else before a
byte is sent -- an edit beside a kept escape byte (the old encoder's anc-9
hazard) leaves an image one byte long.
- write_compliance_config_raw: 512-byte addressed chunks, then confirm 72.
- read_event_index / read_waveform_data_raw unescape before slicing (a block
holding 02/03/04/10 came out short); new read_trigger_config (SUB 0x2E).
- apply_config reads the unit's trigger block. RETRACTED: the block
'hardcoded from 3-11-26 -- no read exists'. Blastware reads it; byte 5 has
been 01 / 03 / 04 by unit and session, and the March copy (03) would have
changed BE9441's (01).
- The call-home write (7E) goes through write_image: its 127-byte 'read + 00 00'
is the 126-byte image (N = 0x7C). No Blastware 7E is on record here -- that
one is inferred from the other 77 write frames.
Tests: tonight's 26 and every Feb-Apr write frame rebuilt byte for byte; each
block as read written exactly as Blastware wrote it; the parser's form; the
stray-byte refusal; the reads against the unit's recorded replies; apply_config
writes BE9441's own trigger block. Six mutants, each caught. The old
test_write_frames.py (25 tests that had been skipping) runs now that the
captures are here, rewritten to the measured model.
Not yet sent to a unit: a config push changes settings, so its first live use
is a bench session with Brian. No codec, store or DB change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
README: the intro no longer calls the Series-IV binary codec 'on the roadmap';
a v0.32.0 status entry; the ingest and Database sections describe the restamp
and estimate rules; the NULL-timestamp roadmap item points at #52.
CHANGELOG: v0.32.0 dated 2026-10-27, when its content was final.
TOOL_VERSION comment: times come from the event record, not the name.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
The release had not shipped, so its entries are corrected in place: the theme,
the time-source entry (the embedded event record, not the filename), the
estimate guard, and a note that the deploy rehearsal stands (record and filename
agree on all 1,394 prod waveforms).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
Brings fix/waveform-time-from-record (f91949b, 6cfcd04, and a docs pointer): the
trigger comes from the event record the unit sends in its 5A stream, validated
strictly; a filename is only a cross-check; no validated record means a
flagged estimate that never overwrites, merges or duplicates a row. Real data,
no names: 7,961/7,961 waveforms on the record, 0 disagreements. Suite vs dev:
the same 16 failures, byte-identical reasons.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL