The trace decoder required all four records 0x3c-0x3f, so BE16352 (no
mic: 0x3c-0x3e only, all 8 of its DL2 events) got no sensor-check traces
at all. The three geophone records, chained by their length prefixes,
are now enough. The .h5 writer already stores a three-channel set.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The record chain that starts with the embedded event record runs to the
file's end on all 70,041 DL2 files: the event record 0x05, the unit's
summary 0x32-0x35, its sensor checks 0x3c-0x3f, then the footer 0x0e
(no 0x35 / 0x3f on a unit without a mic, 8 files). _record_chain walks
it and refuses a chain that does not end exactly at the file's end; the
unit's summary is now read from it too.
Each sensor-check record's header holds the results (DL2, 2026-11-06):
[2] channel type (1 geophone, 2 mic, 0 disabled), [4] status (0 =
passed), [5:7] frequency x 10, [7:9] ratio x 10, [9:11] amplitude mV.
Blastware prints them as they are: 209,943 / 209,943 geophone
frequencies and ratios, 69,975 / 69,975 mic frequencies and amplitudes;
"Passed" on status 0, "Check" on every other (its bits not decoded:
a Check can sit inside every passing range), "Disabled" on type 0.
Event.sensor_check_results: channel -> SensorCheckResult (result,
status, freq_hz, ratio, amplitude_mv). The checker compares them.
Behaviour change: an unknown id inside an intact chain now leaves only
that record unread (was: everything after it).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
After its embedded event record, every Blastware event file carries the
unit's own per-channel summary: a chain of [length][id][payload] records,
ids 0x32 Tran .. 0x35 MicL, each with min, max, peak sample,
half-period and a displacement integral; the event record itself holds
the vector-sum peak's sample. Blastware prints these as they are
(measured on DL2, 2026-11-05):
- ZC frequency = (rate / 2) / half-period: 15,844 / 15,844 waveform and
104,000 / 104,000 histogram values; every word too (">100" at <= 5
samples, "N/A" at 0, "<1.0" beyond rate / 2). Recomputing from the
samples had reached 46%: the unit works at full resolution.
- peak displacement = half the integral x 16 counts x in/s per count /
rate: 19,479 / 19,479 (84% recomputed).
- times of peak and the vector-sum time now come from the unit's peak
samples. They equal the samples' argmax on 25,962 / 25,966 channels;
the 4 others are O117I1NK.R70W, whose stored samples wrap at the
trigger (Blastware's own sample table has the same wrapped values).
The event-record readers return the validated record's offset, so the
summary is read from that spot only. No summary: nothing is set, and
times of peak stay the samples'.
The checker reports ZC frequency and displacement, and reads the mic's
above-range flag under its real name (mic_zc_above_range).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
From the 2026-11-04 bench:
- A MiniMate settings preview warns that a change is lost if someone is in
the unit's setup menu: a write sent with the menu open was acknowledged
and read back, then lost on Cancel or Save -- the menu writes its own
copy of the whole block back (measured both ways on BE9441).
- The two bytes after the MiniMate settings block went out as 00 00 and
the unit took them; the preview note says so instead of 'unmeasured'.
- A Micromate call-home plan no longer warns about 0x00 / 0x01: UM20147
took both, each way, on 11-03 and 11-04, matching its menu.
- read_waveform_data_raw drops the escaped-checksum's stray 0x10, as the
settings read does (it failed closed: the write's block check refused
203 bytes).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
S3_ALARM_WRITE_MEASURED = True. At the bench on BE9441, with Brian's go,
the alarm went 1.0 -> 1.5 -> 1.0 in/s: each write acknowledged, read back
as sent, and shown in the unit's own setup menu. The write moved exactly
channel +39 of the three geophone blocks (the f32 at +38), where the
event files put it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Every printed acceleration in DL2 bounds Blastware's g; together they
leave [386.2236, 386.2240] in/s^2, and 386.2238 fits 19,475 / 19,479
values. The other 4 are one odd file (O117I1NK.R70W, whose peak times
are also off) and one sample mismatch. That is 9.81 m/s^2 (386.2205,
19,423) plus an unexplained offset, as with the mic's fitted dB offset.
The 59 values 9.81 left were all one last digit high.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Group D, part 1, measured on 400 DL2 waveforms (2026-11-04):
- time of peak = (first peak sample - pre-trigger samples) / sample
rate, per channel including the mic: 1,197 / 1,197 geophone values
- the vector sum's time, the same on sqrt(T^2 + V^2 + L^2): 398 / 399
- peak acceleration = the largest |v[i+1] - v[i]| x sample rate / g,
with Blastware's g = 9.81 m/s^2: 1,190 / 1,197 (the standard 9.80665
gives 1,073). Blastware's manuals: 'subtracts two velocity readings
and divides the result by the elapsed time between them'.
PeakValues gains *_time_of_peak, pvs_time and *_peak_accel_g, filled
for waveforms only. The checker reports them. Displacement (84% with
the manuals' half-cycle integral) and ZC frequency (46%) are not shipped
yet -- Blastware does something more there.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Bench 2026-11-04, BE9441 live: frame B of a 1A read arrived one byte long,
ending in a lone 0x10. When a frame's checksum byte is itself escaped
(02 / 03 / 04, about one frame in 85) the parser keeps the escape's 0x10
and strips only the byte after it. The 12 recorded reads never hit it,
so the assembled block was 2,091 bytes and SFM refused it as 'monitoring'.
read_compliance_content now passes the lengths it asked for (1024, 1024,
42) and that one stray byte is dropped; any other leftover still fails
is_compliance_content. The trimmed read decodes exactly as the old
decoder read the same reply.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Since #51 a waveform and a histogram recorded in the same second are two
events (UNIQUE(serial, timestamp, record_type)). persist_download's
'already stored?' checks matched any row at the second and any row under
the letterless Blastware name both twins share, so a live download of
one twin was skipped as stored. Both checks now hold to the download's
own type, read from its file (STRT[18]; IDFW / IDFH); an untyped row at
that second, or a download whose type does not read, still counts as
stored. find_event_by_blastware_name takes an optional record_type.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Brings the checker's file-only decode work onto the parity branch so the
phase-5 bench runs on the code that will ship. One conflict, the CRLF
Series-III reference changelog: both kept, phase 5's row numbered
'2026-11-03 (5)' above dev's (4)/(3)/(2). test_event_ingest's live-
histogram dedup test asserted the stored row sits a second off the 0C
time -- the #51 bug, fixed on dev -- so its premise now reads the event's
own second; the dedup it tests still holds.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
From the whole-branch review of phase 5:
- The preview's revision now covers the changes asked for, so a live
change must be exactly what was previewed (any API caller, not only the
page). It covers what the preview showed -- the settings block (and a
Micromate's setup name) -- not the blocks a write only echoes, which are
re-read at send and sent as read (a MiniMate's trigger block byte 5
differs by session, #46).
- The units' limits hold on the block that would result: a range, rate or
mode change alone can no longer leave a held trigger, alarm or record
time over them.
- Every MiniMate block read is logical, so push_config_raw no longer
unescapes again (a job number of 4098, 10 02, was refused at Send); the
preview runs the write's own block check, so a block it would refuse is
shown as blocked.
- A MiniMate's monitoring refusal says a stop makes it call in (spec).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
The Config tab by serial is now the unit's edit form, headed 'On the
unit <serial> -- read HH:MM' and built from the server's editable
fields. Preview runs a dry run and shows old -> new, notes and anything
that blocks the change; Send (confirm) sends exactly what was previewed,
with its revision, then shows what the unit now holds and re-reads it.
An edit after a preview disables Send until the next preview. The
by-host form loses its write button; the read stays. Logic in
device_routing.js (Node-tested), glue in sfm_webapp.js, no inline JS.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
DeviceAccess.change_settings refuses before any I/O a request with no
changes, a live change without its preview's revision, or no audit log,
then dispatches the series' change (never retried). The route returns
the preview (fields old -> new, warnings, blocked, revision) or the
result (fields old/new/now), statuses as the other changes, and marks
the cached by-host config dirty after a live change.
/device/config and /device/config/project now answer 410 with a pointer.
Deleted with them: MiniMateClient.apply_config / set_project_info and
the raw-offset _encode_compliance_config (#46 found it wrong), the
lab script poc_set_project.py and experiments.py's EXP6, both of which
wrote a live unit through it. Git keeps them.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Series3Adapter.settings reads the 1A block assembled into its 2,090
logical bytes and decodes it with micromate.setup_fields (a monitoring
unit's device-info answer is refused with 'stop monitoring first').
change_settings runs the shared change core: read the four settings
blocks, patch the settings block's fields, send Blastware's sequence
through push_config_raw with the event index, trigger and waveform blocks
as read, re-read. Refused before sending: monitoring, a value the unit
does not allow, a stale preview. push_config_raw's pre-check now raises
ImageRefused, so a refused image is audited as nothing sent.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
s4_change_settings runs the shared change core with a read-back verdict
for its state (as asked / unchanged / differs). It reads the active
setup's name (unstripped), the preferences, trigger and setup blocks and
the schedule; patches the setup through micromate.setup_fields; sends
THOR's setup push (0xDA 68 73 82 83 71 72, now enableable) once; reads
the setup back. Refused before sending: a monitoring unit, a value the
unit does not allow (422), a stale preview (SettingsChanged, 409), and --
shown as 'blocked' in the preview -- the factory setup, a schedule that
loads another setup, an unreadable schedule, or a block SFM has not seen
(ChangeRefused, 409). s4_settings carries the editable fields.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
MicromateProtocol.read_file: 0x94 + path, then 0x48 pages to an
all-zero reply -- THOR's frames byte for byte (UM12947, 2026-09-24),
including params[3] = 1 on 0x94 and params[7] = 1 on the first 0x48.
micromate.schedule parses the 260-byte records (two- and five-entry
schedules from THOR's captures) and names the scheduled starts that
would load a setup other than the active one, ignoring case. The
client gains the raw (unstripped) active-setup name and the prefs /
trigger / setup content reads a setup push sends back.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
With the start right, the rest of Blastware's histogram timing follows,
measured on a 2,000-histogram DL2 sample:
- each interval's printed time is its end, start + (i + 1) x interval,
capped at the stop: 2,308,524 / 2,308,524 rows
(event_file_io.interval_times)
- each of Tran / Vert / Long / PVS / MicL's peak date and time is that of
the interval holding its first maximum: 2,000 / 2,000 each.
The checker compares intervals.Time and the ten peak date/time fields.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The footer's start runs a second early on 97% of histograms. Each
histogram carries an event record like a waveform's -- lead 00 28 05 00,
source 04 00, marker fe f5, then start and stop -- and it holds
Blastware's Histogram Start and Stop on 63,490 / 63,490 DL2 histograms.
On all 63,500 there is exactly one, its start 0 or 1 s after the
footer's and its stop 0 or 1 s before; that is the validation rule.
Without a validated record the footer's start stands, as a decode
problem.
Ships with the unit + time + type key (ea2dfc2), without which a
waveform and its histogram at the same second would collide. Three
tests that pinned the old footer start (one said 'for now', pointing at
#51) now pin the record's, which equals the file's Blastware name.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
micromate/setup_fields.py: the fields an operator can change (record
mode, sample rate, interval, record time, geophone trigger, Series 3's
range and -- read-only until benched -- alarm, job number and its report
flag, the four notes by slot), the units' own limits from Instantel's
manuals, field-only byte patching (bit fields bit by bit; Series 3's
[26:28] as Blastware writes it; Series 4's CRC recomputed), the
read-back verdict compared by bytes, and the preview revision.
All 11 Blastware compliance writes reproduce from the block before them
(BE11529's first also shows Blastware re-rendering two mic levels
through its dB value; SFM echoes the unit's bytes); Series 4 keypad
fixtures reproduce pairwise.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Under the unit + time + type key, the test's untyped neighbour no longer
shared the imported waveform's key, so the waveform was stored as its
own row -- the neighbour untouched, which is what the test's name asks.
The guard's job is an estimate landing on another waveform's second, so
the neighbour is now a waveform. A companion test pins the case the new
key allows: an estimate beside a histogram at its second is stored
alongside it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The events table was UNIQUE(serial, timestamp): one event per unit per
second. A unit records a waveform and a histogram in the same second
legitimately -- 209 times in prod's 2026-09-30 store once histograms
carry Blastware's start -- so the key is now (serial, timestamp,
record_type). Agreed with Brian 2026-11-03.
- Migration 3 rebuilds the table from its own current definition with
only the key swapped, in one transaction: every column, row and id is
kept (Terra-View reads rows by id) and the indexes are recreated.
Migration 1's check no longer mistakes the new key for a missing one.
- The upsert, the estimate guard and the restamp match on the type too.
The restamp also re-types a file's own row in place: before v0.33.0 a
row's type came from the filename, and a re-import under the file's
own type must not add a second row.
- An untyped event still refreshes the untyped row at its second (a
UNIQUE key treats NULLs as distinct).
- scripts/repair_unknown_serials.py checks the new key.
No time changes yet: that is the next commit, and they ship together.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Unescape each 1A data frame, take data[11:], drop the one non-content
byte that starts every frame but the last: 2,090 bytes headed by
N = 2090, Series IV's 0x1A layout. Measured on BE9441's 10-26
recording (12 reads, both frame patterns); the read after each
Blastware write equals the image written. read_compliance_content is
strict (a missing frame raises) and unjudged (a monitoring unit's
device-info answer comes back for the caller to recognise).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Blastware prints OORANGE for an interval's vector sum when it exceeds
the range in an interval where Blastware also clamped a channel: 17 / 17
DL2 cells, SFM's sum 10.01 .. 17.33 in/s (sqrt 3 x 10.005). The
saturation carve-out now covers intervals.Geo PVS in/s with that rule,
per interval, as it already did for PeakVectorSum. The 4 other cells
left mismatching sit 4e-6 past a rounding boundary (Blastware's
arithmetic is a hair lower) and stay mismatches.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Group B of the file-only decode, measured on DL2 2026-11-03:
- Frequency = (sample rate / 2) / half-period: 527,915 / 527,915 cells
at 1024 sps and 1,725 / 1,725 at 2048. #50: half_period_to_hz took a
fixed 512 and halved every 2048-sps frequency; it now takes the rate
(default 1024). Blastware prints 'N/A' for a half-period of 0, '>100'
('>200' at 2048) at 5 samples or fewer, '<1.0' below 1 Hz.
- Each interval's vector sum, sqrt(PVS^2) at the event's range:
771,354 / 771,354.
- Interval size: uint16 seconds at k - 40 (Series IV [8:10]).
- Stop: the footer's (2,995 / 2,999 sampled; 4 print a second earlier).
Event gains histogram_interval_sec, interval_half_periods, interval_pvs
and stop_time; the .h5 gains /intervals/half_period/<ch>,
/intervals/pvs_ips and a histogram_interval_sec attr. The decoder walks
a histogram once (histogram_codec.channels_from_records) and takes the
event's PVS from the same records. The checker compares each interval
column, number or Blastware's word; the test that pinned Tran Freq Hz
as blank now pins the match.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Brings be5bab4 and its history from the decode checker's branch: a Blastware
file's job number; decode_blastware_bytes choosing the codec by STRT[18] and the
histogram layout check by peak <= PVS <= sqrt(3) peak; the footer as the file's
last 26 bytes (no day-late histograms); docs (reference Appendix D.6, the
file-only status).
Conflicts, both kept whole:
- CLAUDE.md: this branch's 'Narrowed 2026-10-26' 5A block stays, followed by
dev's 'Open, not blocking' line (the 8x sensitive-range item struck out --
resolved by the file's range).
- docs/instantel_protocol_reference.md (CRLF, byte-safe): the change-log rows in
date order -- dev's 2026-11-03 and 2026-11-02, this branch's 2026-11-03
(call home), 2026-10-29 and 2026-10-27 (#46, this branch only).
Suite on the merged tree: 1399 passed, the 16 known failures.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Measured at the bench 2026-11-03 (UM20147): monitoring, a Micromate returns its
real call-home block and ACKS a call-home write, but does not apply it -- three
read-backs unchanged, and its own menu says 'Feature disabled while monitoring'.
SFM now refuses up front (UnitStateUnknown, 409: '... is monitoring -- a Micromate
ignores call-home changes while monitoring ...; stop monitoring first -- nothing
sent'), dry run included, instead of sending a write the unit ignores.
And the block must be the call-home block: micromate.writes.is_call_home_content
checks its header is its own length (00 7C, N = 124 -- 00 7C DC on every read,
UM12947 and UM20147). plan_call_home_enabled refuses any other 126 bytes, the
change refuses before sending, and call_home_state says why (enabled = None).
At the bench this was checked by eye before the monitoring write.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Measured at the bench 2026-11-03 (BE9441): while monitoring, a MiniMate answers
the 0x2C call-home read with its DEVICE-INFO block ('Instantel', 'MiniMate Plus',
its serial) -- as it answers 1A -- and idle again, minutes later, the call-home
block. SFM writes back only a block it just read, so a monitoring MiniMate's
call-home cannot be changed; the change core already refused (byte 5 read as
'unknown(0x6E)', nothing sent), but said so cryptically.
- minimateplus.protocol.is_call_home_block(raw): the block starts with its own
length 0x7C and is N (or N + 2) bytes unescaped; the device-info block fails it.
- The Series-3 change raises UnitStateUnknown (409) with 'did not return its
call-home settings -- a MiniMate answers the call-home read with its
device-info block while monitoring; stop monitoring first ... nothing sent',
for a dry run too. call_home_state returns enabled = None with that reason.
- The page's callHomeRows shows the reason in place of 'Unknown (byte 5 = ...)'.
A blind write while monitoring stays untested on purpose.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
K441LA17.IN0W's report says Units 'in/s and psi(L)' yet prints
MicTriggerLevel '125.0 dB(L)'. The value states its own unit, so that
is the one compared; the report's Units is the fallback. It was the
only MicTriggerLevel mismatch in DL2 (SFM's 0.005158 psi is 125.0 dB).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Group A of the file-only decode, every field matched against every DL2
report (2026-11-03):
- Identity block before the setup name, what the live read gets from
SUB FE: serial k-202, firmware k-147, DSP version k-138, calibration
date k-132 + 'by' k-128, manufacturer k-94, model k-72, firmware
minor k-193. Event.device_info (DeviceInfo gains calibration_date /
calibrated_by). Serial, Version and Calibration 69,983 / 69,983.
- Battery: uint16 hundredths of a volt at k-190 (Event.battery_volts).
69,729 exact; the other 254 are Blastware rounding half up.
- Trigger source: the two bytes between the embedded event record's
lead and fe 80, a bitmask (0x01 Tran 0x02 Vert 0x04 Long 0x08 MicL
0x200 Manual): 6,493 / 6,493. Event.triggered_by.
- Trigger settings in Series IV's 0x1A layout: sources bitmask k-19,
stop mode k-31 (0 = Fixed), each channel's float32 level at
label+30 (geo in/s, mic psi), mic type code at MicL+4 (2 = Linear
Weighting). Geo level 6,447 / 6,447, mic 4,403 / 4,403; Blastware
prints a level when its channel is a trigger source and the event
was not Manual. The mic level's dB uses 6895 Pa/psi (4,272 / 4,272
against 4,271 at 6894.757).
- .h5 attrs for all of them (additive).
- Checker: SFM's side reports the ten fields; the mic trigger level
follows the report's dB/psi. Carve-out
units-is-a-display-preference: dB or psi is Blastware's PC setting
when it wrote the report -- DL2's reports switch fleet-wide in 61
clean runs by write time, and no byte of the file separates them.
Two tests that pinned BatteryLevel / Calibration as blank now pin the
match.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Every DL2 file ends in a valid footer: 0e 08 and two valid times on
70,041 / 70,041. The decoder took the first '0e 08 + plausible year'
instead, and 14 files also hold an earlier record, ~1.1 KB before the
end, with the stop time followed by zeros:
- a histogram started at its own stop -- a day late on BE9558's daily
histograms (K558L9XP.FK0H: 2025-10-08 19:10:01 for Blastware's
2025-10-07 19:14:08); T003LCYV.JD0H got no time at all;
- a waveform lost its stop, so the trigger was never computed and the
stop was stamped instead (K440I4LG.JK0W: 11:14:12 for 11:14:08).
The last 26 bytes are now taken when they are a footer; otherwise the
old search stands unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
- s4_change_call_home's read_state now returns an unknown(0xNN) run state as
it is, so the change core refuses it (UnitStateUnknown, nothing sent), as
start/stop already does; it checked only for calling_home.
- run_change records the snapshot on the lost-ack path too: after an ack is
lost, what the unit now holds (and, on Series 4, whether [118:120] moved) is
what tells whether the write landed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
call_home_image returns the unescaped N + 2 image, but the send path handed it
to write_call_home_config, whose write_image unescapes again -- and unescaping
is not idempotent: a real 0x10 before 02/03/04 loses its 0x10. A call-in time
of 16:02-16:04 (hour 0x10) is exactly that. One such time made the send refuse
before the wire yet audited as 'sent, acknowledgement lost'; two made it send a
block shifted by two bytes from [101] (num_retries and the time fields wrong).
The Blastware-frame test could not see it: it checked the image builder, not
the bytes the protocol framed.
- MiniMateProtocol.write_call_home_image(image) frames a built image once
(0x7E, ack 0x81, 0x7F, ack 0x80), raising ImageRefused before any byte when
it is not a whole block; write_call_home_config (the legacy multi-field path)
is write_image once + that. Its stale 127-byte docstring is gone.
- MiniMateClient.write_call_home_image uses it.
- The Series-3 change passes is_refusal=ImageRefused, so a pre-wire refusal is
audited as nothing sent (sent = 0), not as a lost ack.
Tests drive the real client -> protocol over a stub answering with BE11529's
recorded acks: the unit's own read, a 16:02 time, and 16:03 + 16:04 all go out
exactly as built; a short image is refused with nothing written.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Two test-side breaks, found by the full suite after phase-4 task 6:
- test_micromate_framing's three whole-session tests pinned exact counts of a
gitignored corpus (bridges/captures/9-24-26 - micromate2, a symlink into the
main checkout). The full copy of the BW VM's captures on 2026-11-02 added
sessions: 287 responses / 241 reads / 287 requests, every one passing the same
per-frame checks. The counts are now floors (>= 251 / 218 / 251), so a lost
file still fails and a grown corpus does not.
- test_micromate_opcodes' beyond-the-ceiling permit took 0x7E, enableable since
the call-home commit (eeb55ef); 0x71 (the setup write, phase 5) replaces it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
device_routing.js (Node-tested): call_home_state / call_home_on / call_home_off
routes (serial required); controlsFor gains callHomeChange (by serial, a
confirmed Series 3 or 4) and callHomeRead now covers a Series 4 by serial;
serialPanes gains callHomeForm / callHomeBox; callHomeRows renders the switch
(On / Off / 'Unknown (byte 5 = 0xNN)'), dial string and series;
changeErrorText takes the whole label ('Start monitoring', 'Enable call-home').
sfm_webapp.js: by serial the Call Home tab hides the legacy multi-field form
(Series 3 by host only) and shows the unit's switch with On / Off. Each asks
confirm(), sends one audited change, reports it with changeSummary /
changeErrorText, then re-reads quietly so the change's own result stays on
screen. A different unit's switch is never left showing. The new buttons are
wired with addEventListener, not onclick= (no inline JS).
Checked in jsdom against the real page: placeholder, read, Off (confirm, the
disable route, 'confirmed -- enabled -> disabled'), a serial edit clearing it,
legacy mode unchanged, no script errors.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- DeviceAccess.call_home_state (a read) and set_call_home (change=True: never
retried, audit required for a live change, dry run without one), routed by
series like start/stop. A config write is read back on its own window: up
to 3 reads, 1 s apart, not the monitoring one.
- Routes, serial required (422 without), all three serial-aware: the state as
a dict; enable / disable through _change_response, so their statuses are
start/stop's and an unconfirmed change carries sent + audit_id. The legacy
GET / POST /device/call_home are unchanged (a Micromate serial is still
refused there, 501).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Ground truth: Blastware changing BE11529's call-home settings on 2026-04-20
(Remote Access -> Setup Unit), paired raw files of what it sent and what the
unit answered: the read, the enable (read 0x00 -> wrote 0x01), the disable
(read 0x01 -> wrote 0x00). From the unit's own read before each write, SFM's
0x7E frame (call_home_image + build_bw_write_frame) is Blastware's byte for
byte -- nothing but byte 5 differs from the read -- and the 0x7F confirm too.
Mutation-checked: inverting the byte SFM writes fails the test.
S3_CALL_HOME_FRAME_VERIFIED is now True; the gate stays tested shut by
monkeypatch, and a test pins that its comment names this proof.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- minimateplus.protocol: call_home_enabled(raw) reads byte 5 of the UNESCAPED
0x2C payload (0x01 on / 0x00 off, measured 2026-04-20; anything else None --
bench finding #1's lesson: an escaped byte before it would move the raw
index); call_home_image(raw, enabled) is write_image's N + 2 image with byte 5
set and everything else as read, refusing a byte 5 never measured.
- MiniMateClient.read_call_home_raw() / write_call_home_image(image) (0x7E then
0x7F, each ack checked, never retried).
- Series3Adapter.call_home_state (wake, then 0x2C; no serial read, like status)
and change_call_home: the shared change core with a connect() identity check,
state 'enabled' / 'disabled' / 'unknown(0xNN)' (unknown sends nothing), the
plan showing both exact frames, a snapshot of both unescaped images.
- S3_CALL_HOME_FRAME_VERIFIED = False: a live change is refused (501) before any
connection until the frame is reproduced from Blastware's (next commit).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- micromate: ENABLEABLE_WRITES gains 0x7E/0x7F (the call-home write and its
confirm; spec row 9, enable/disable only); MicromateClient.get_call_home_content()
returns the 126-byte 0x2C content.
- sfm/device_access: CallHomeState (serial, series, enabled, dial_string, detail
with byte5 and the whole block); s4_call_home_state reads bit 0 of [5] and the
dial string at [6:46]; s4_change_call_home runs the shared change core with
micromate.writes.plan_call_home_enabled -- built from the read run_change made
just before, and that same plan is the one sent. A unit calling home (run
state 0x03) is refused, nothing sent. The read-back judges the edited bit
only; the snapshot records both blocks and every changed offset -- [118:120]
is unit-maintained and always moves.
- The write-ceiling tests take 0x71 (the setup write, phase 5) as their
over-the-ceiling example now that 0x7E is enableable.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
run_change named its change and its target state from a start/stop bool. A
ChangeKind (action, want, became) now says what the change is called and which
state read back means it took; monitoring_change(start) gives exactly today's
names, call_home_change(enabled) the new ones. An optional snapshot hook
records what the unit holds after the change in the result and the audit row
(never the verdict; one that raises is recorded as its error).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- #6 Config tab by serial: the empty legacy edit form stays hidden (settings
are read-only until phase 5); the settings box shows from the start, 'Not read
yet', and a different unit's settings are never left on screen.
- #10 A start/stop that went out but was not confirmed is no longer called
'failed'. The route now adds 'sent' (acknowledged / unknown) and 'audit_id'
to a ChangeUnconfirmed -- same status, same message -- and the page says
'Start monitoring not confirmed: <what happened, audit record>'.
- #12 Device tab by serial: the empty legacy Compliance/Project tables are
hidden behind a pointer to the Config tab; a Micromate's Firmware card reads
'Thor line (version not read)' (its version string is in 0x01, undecoded).
- #16 A 504 with nothing sent adds: the connection opened, so the modem is
reachable -- another program (THOR or Blastware) may be holding the line, or
the unit is busy. Measured 2026-10-29: THOR polling leaves SFM a 0-byte 504.
New logic lives in sfm/static/device_routing.js (firmwareLabel,
deviceErrorText, changeErrorText, serialPanes) under Node tests; the page glue
in sfm_webapp.js only applies them. Checked in jsdom against the real page
(served at a fake origin, /static from disk): all four, legacy mode unchanged,
no script errors.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Three causes behind the histograms the checker found decoding wrongly:
1. The file decoder tried the waveform codec first, whatever the record
type. It accepted BE9440 / BE9557 / BE17354's 2018 5 s histograms and
returned ~5x too many 'samples' (K440HDXX.XH0H: SFM 44,504, Blastware
6,976). The codec now follows STRT[18] (0x46 / 0x0A on 70,041 /
70,041 DL2 files); only an unknown type falls back to trial order, and a
chosen codec that fails is a decode problem rather than a silent switch.
2. The sub-minute layout check required each record's 'zero word' to be
0000. It is the high word of the interval's PVS squared, non-zero above
1.28 in/s, so a one-block histogram with a loud interval was not
recognised (T193KR5M.X90H, K440HA3C.JM0H, R352HFZ7.530H decoded to
nothing). The check is now the measured relation peak <= PVS <=
sqrt(3) * peak, which holds on 34,502,955 / 34,502,955 DL2 sub-minute
intervals. The no-terminal-tail trim uses the same test. Two test
builders wrote PVS bytes no real record has (one still in the retracted
little-endian layout); they now write peak^2 in the measured layout, and
the retraction test keeps a legacy builder of its own.
3. Checker carve-out interval-count-is-duration: Blastware's Number of
Intervals is (stop - start) / interval from the footer times, and its
own interval table lists one block fewer when the unit never wrote the
last minute. SFM matches the table (T193KSWP.FF0H: 2,880 vs 2,850).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Stack-wide rule since 2026-11-02 (terra-view docs/tmi-stack.md, Terra-View's
rule 4): no inline JavaScript, because a test cannot load it. This page's tests
had to regex their code out of the HTML. Batch 2 edits both of the page's
scripts, so they come out first, verbatim:
- sfm/static/device_routing.js: the tested routing rules (157 lines)
- sfm/static/sfm_webapp.js: the rest of the page (2,274 lines)
The page loads them with <script src="static/..."> where the inline scripts
were, so load order and the onclick handlers are unchanged. Verified: putting
the files back inside those tags reproduces the old sfm_webapp.html byte for
byte, and a jsdom page check (served at http://sfm.local/, /static from disk,
no network) gives identical output before and after.
The server serves sfm/static/ at /static/, with Cache-Control: no-cache so a
browser revalidates (a cheap 304) and a new SFM never runs a cached old
script. Opened from disk, the page needs its static/ folder beside it.
Tests: the routing tests load the file instead of regexing the HTML; new
test_webapp_static pins no inline <script> in the page and the /static route
(through the whole app, middleware included).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
The setup block has Series IV's 0x1A layout here too: report flags at
k - 9 (bit 0x02 = job number shown) and the number, uint16 BE, at k - 8,
kept while switched off. The flag matches Blastware's JobNumber on
2,997 / 2,997 DL2 events that print one and 66,986 / 66,986 that don't.
Every printed value is 1 and matches; hidden ones hold real numbers
(802, 1012, 1013, 622), so the value is only proven for 1.
- ProjectInfo.job_number_enabled / job_number, named as in
micromate.setup_block.
- write_event_hdf5 stores both as .h5 attrs when read (additive).
- The checker reports the number only when shown, and scores a number
only SFM shows as a mismatch. The old test that pinned JobNumber as
sfm_blank now checks only the ZC cases it also covered.
Not carried into the DB, the API or the PDF report yet (needs a column).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
With the decode checker's fixes merged (histogram vector sum 625bc39, mic psi
5644dbd, the file's geophone range 4844135), the event file reads everything
Blastware reports. So a live download's row and samples are now the file's:
peaks, vector sum, mic -- and the geophone range from the file's own setup
block, the setting when the event was recorded. The live 1A is the unit's
setting now, which may have changed since; it is the fallback only when the
file's range does not read.
Measured: K557J1KB.RQ0W (Sensitive waveform) downloaded with its settings unread
-- e.g. while monitoring -- stores 0.019 / 0.055 / 0.019 and PVS 0.061,
Blastware's report; its .h5 read 0.155 / 0.44 (8x) before. M010HR6K.OA0H
(Sensitive histogram) likewise. K441LTON.900 (Normal) stores Blastware's
values whatever the unit's current settings say, and its mic is 5.80e-4 psi
(Blastware: 106.0 dB(L)).
The unit's 0C summary stays the download check, and fills in the channel peaks
and vector sum only when the file's range does not read (never seen in DL2) and
the unit is not confirmed Normal -- the impossible-vector-sum guard kept there.
The mic is the file's always. Closes the range part of open finding #17.
Store consequence: new live downloads only; no backfill, no migration.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Brings 057df47 (fix 4844135, changelog be58b4f) from the decode checker's branch
-- Event.geo_range from the file's setup channel block (label+29: 0 Normal,
1 Sensitive, None not read), peaks and histogram PVS scaled by it,
write_event_hdf5(geo_range=None) using it -- and dev's v0.33.0 release commit
(6c7c6b0).
Conflicts, resolved as agreed with the decode session:
- sfm/waveform_store.py save_imported_bw: dev dropped the forced
geo_range="normal"; this branch keeps its geo_range parameter, now
Optional, default None -- an import uses the file's own range, an explicit
value (a live download's) still wins.
- CLAUDE.md: dev's newer 'Where things stand (updated 2026-11-01)' date.
Measured on the merged tree: K557J1KB.RQ0W (Sensitive waveform) decodes
0.019 / 0.055 / 0.019, PVS 0.061 -- Blastware's report -- and its imported
.h5 peaks 0.0194 / 0.055 / 0.0194 (forcing 'normal' gives 8x: 0.155 / 0.44).
M010HR6K.OA0H (Sensitive histogram) likewise. The live path still passes the
unit's 1A range or 'normal' when unread -- unchanged by this merge.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
In the setup's channel blocks, the byte 29 after each geophone label is
the range: 0x00 Normal (10 in/s), 0x01 Sensitive (1.25 in/s). It matches
Blastware's GeoRange on 70,042 / 70,042 DL2 events, all three channels
agreeing on every one (35 Sensitive). SFM's live 1A has the same byte
at label+33. SFM assumed Normal, so every Sensitive event's peaks,
vector sum and .h5 samples read 8x high.
- Event.geo_range (0 / 1, None when not read -- channels disagreeing,
an unknown value or a missing block -- with a decode_problems entry).
- decode_blastware_bytes scales peaks and the histogram vector sum by it.
- event_hdf5.write_event_hdf5: geo_range defaults to None = the event's
own, else Normal; an explicit argument still wins.
- waveform_store.save_imported_bw and scripts/backfill_sidecars.py stop
forcing 'normal', so imports and the backfill store the file's range.
The waveform_store line was agreed with the parity session, which owns
that file; its own branch keeps a geo_range parameter, defaulting to
None at its next dev merge.
- The checker's SFM side converts at the event's range and reports
GeoRange; tests that pinned the old 8x gap now pin the fix, and the
saturation carve-out is still tested against an 8x value.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
The checker caught 280 regressions in the first mic fix: every one a dB
value at count 129, where 20 log10(129 x 0.25 Pa / 20 uPa) = 124.149997
rounds to 124.1 and Blastware prints 124.2. Blastware's dB offset sits in
[81.9383, 81.9385] -- any value there matches its dB(L) on 1,729,252 /
1,729,253 DL2 intervals (the last printed '0.000'); exact 81.93820 rounds
count 129 down, and the old 81.94 misses counts 119 and 132. Single
precision does not explain it. psi keeps 0.25 Pa per count, which
matches every interval.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
SFM converted mic counts to psi with a '~0.5 psi full-scale' guess
(0.0125 / 32768 psi per count). Measured against 1,729,253 DL2
histogram intervals' 'MicL Peak' columns: one count is exactly 0.25 Pa.
count x 0.25 Pa matches Blastware's psi(L) on every interval, and
20 log10(count x 0.25 Pa / 20 uPa) its dB(L) on all but 17 exact
half-way cases.
- event_file_io: _MIC_FS_PSI -> _MIC_PSI_PER_COUNT = 0.25 / 6894.757
(3.626e-5 psi per count, was 3.81e-7). The event's mic peak in psi,
and with it the .h5 mic trace (event_hdf5 back-solves its scale from
that peak), come right on events with no report.
- waveform_codec.mic_count_to_db: the offset is 20 log10(0.25 / 20e-6)
= 81.938, not 81.94 -- the old value missed 49 of those intervals at a
rounding edge (count 119 printed 123.4, 81.94 gave 123.451).
The decoded count was always right: count 16 on K441LTON.900 is
Blastware's 106.0 dB.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9