A MiniMate sends a checksum of 02, 03 or 04 as `10 X`. S3FrameParser kept
both bytes and _finalise took only the last as the checksum, so the frame's
data ended in a stray 0x10. It now takes the pair.
Measured on every recorded reply (60 captures, March to October 2026): SUM8
of the unescaped payload is the checksum on 7,747 of 7,747; 272 arrived
escaped, all valid as an escape pair.
What the stray byte did:
- 1C status: battery and memory are counted from the end; 12 of 760 recorded
status replies read 419.84 V / 251,654,656 bytes (6.76 V / 983,026).
- 2C call-home read: one byte long, refused as "monitoring".
- 1A, 09 reads: already trimmed (bench 2026-11-04); the trims stay as guards.
- 5A file builder: compensated in _frame_body_bytes; that pairing is removed,
else a real 0x10 ending a chunk (one in ten do) would be dropped.
Stored .a5.pkl frames: A5_PICKLE_VERSION 2; load_a5 drops the stray 0x10
from version-1 frames. All 28 pickles on this box rebuild byte-identical
to dev's build.
Operational consequence: none for prod's stored events (S3 events arrive
through save_imported_bw, which keeps no frames); no schema change, no
TOOL_VERSION bump, no backfill.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
From the 2026-11-04 bench:
- A MiniMate settings preview warns that a change is lost if someone is in
the unit's setup menu: a write sent with the menu open was acknowledged
and read back, then lost on Cancel or Save -- the menu writes its own
copy of the whole block back (measured both ways on BE9441).
- The two bytes after the MiniMate settings block went out as 00 00 and
the unit took them; the preview note says so instead of 'unmeasured'.
- A Micromate call-home plan no longer warns about 0x00 / 0x01: UM20147
took both, each way, on 11-03 and 11-04, matching its menu.
- read_waveform_data_raw drops the escaped-checksum's stray 0x10, as the
settings read does (it failed closed: the write's block check refused
203 bytes).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Since #51 a waveform and a histogram recorded in the same second are two
events (UNIQUE(serial, timestamp, record_type)). persist_download's
'already stored?' checks matched any row at the second and any row under
the letterless Blastware name both twins share, so a live download of
one twin was skipped as stored. Both checks now hold to the download's
own type, read from its file (STRT[18]; IDFW / IDFH); an untyped row at
that second, or a download whose type does not read, still counts as
stored. find_event_by_blastware_name takes an optional record_type.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Brings the checker's file-only decode work onto the parity branch so the
phase-5 bench runs on the code that will ship. One conflict, the CRLF
Series-III reference changelog: both kept, phase 5's row numbered
'2026-11-03 (5)' above dev's (4)/(3)/(2). test_event_ingest's live-
histogram dedup test asserted the stored row sits a second off the 0C
time -- the #51 bug, fixed on dev -- so its premise now reads the event's
own second; the dedup it tests still holds.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
From the whole-branch review of phase 5:
- The preview's revision now covers the changes asked for, so a live
change must be exactly what was previewed (any API caller, not only the
page). It covers what the preview showed -- the settings block (and a
Micromate's setup name) -- not the blocks a write only echoes, which are
re-read at send and sent as read (a MiniMate's trigger block byte 5
differs by session, #46).
- The units' limits hold on the block that would result: a range, rate or
mode change alone can no longer leave a held trigger, alarm or record
time over them.
- Every MiniMate block read is logical, so push_config_raw no longer
unescapes again (a job number of 4098, 10 02, was refused at Send); the
preview runs the write's own block check, so a block it would refuse is
shown as blocked.
- A MiniMate's monitoring refusal says a stop makes it call in (spec).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
The Config tab by serial is now the unit's edit form, headed 'On the
unit <serial> -- read HH:MM' and built from the server's editable
fields. Preview runs a dry run and shows old -> new, notes and anything
that blocks the change; Send (confirm) sends exactly what was previewed,
with its revision, then shows what the unit now holds and re-reads it.
An edit after a preview disables Send until the next preview. The
by-host form loses its write button; the read stays. Logic in
device_routing.js (Node-tested), glue in sfm_webapp.js, no inline JS.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
DeviceAccess.change_settings refuses before any I/O a request with no
changes, a live change without its preview's revision, or no audit log,
then dispatches the series' change (never retried). The route returns
the preview (fields old -> new, warnings, blocked, revision) or the
result (fields old/new/now), statuses as the other changes, and marks
the cached by-host config dirty after a live change.
/device/config and /device/config/project now answer 410 with a pointer.
Deleted with them: MiniMateClient.apply_config / set_project_info and
the raw-offset _encode_compliance_config (#46 found it wrong), the
lab script poc_set_project.py and experiments.py's EXP6, both of which
wrote a live unit through it. Git keeps them.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Series3Adapter.settings reads the 1A block assembled into its 2,090
logical bytes and decodes it with micromate.setup_fields (a monitoring
unit's device-info answer is refused with 'stop monitoring first').
change_settings runs the shared change core: read the four settings
blocks, patch the settings block's fields, send Blastware's sequence
through push_config_raw with the event index, trigger and waveform blocks
as read, re-read. Refused before sending: monitoring, a value the unit
does not allow, a stale preview. push_config_raw's pre-check now raises
ImageRefused, so a refused image is audited as nothing sent.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
s4_change_settings runs the shared change core with a read-back verdict
for its state (as asked / unchanged / differs). It reads the active
setup's name (unstripped), the preferences, trigger and setup blocks and
the schedule; patches the setup through micromate.setup_fields; sends
THOR's setup push (0xDA 68 73 82 83 71 72, now enableable) once; reads
the setup back. Refused before sending: a monitoring unit, a value the
unit does not allow (422), a stale preview (SettingsChanged, 409), and --
shown as 'blocked' in the preview -- the factory setup, a schedule that
loads another setup, an unreadable schedule, or a block SFM has not seen
(ChangeRefused, 409). s4_settings carries the editable fields.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
The events table was UNIQUE(serial, timestamp): one event per unit per
second. A unit records a waveform and a histogram in the same second
legitimately -- 209 times in prod's 2026-09-30 store once histograms
carry Blastware's start -- so the key is now (serial, timestamp,
record_type). Agreed with Brian 2026-11-03.
- Migration 3 rebuilds the table from its own current definition with
only the key swapped, in one transaction: every column, row and id is
kept (Terra-View reads rows by id) and the indexes are recreated.
Migration 1's check no longer mistakes the new key for a missing one.
- The upsert, the estimate guard and the restamp match on the type too.
The restamp also re-types a file's own row in place: before v0.33.0 a
row's type came from the filename, and a re-import under the file's
own type must not add a second row.
- An untyped event still refreshes the untyped row at its second (a
UNIQUE key treats NULLs as distinct).
- scripts/repair_unknown_serials.py checks the new key.
No time changes yet: that is the next commit, and they ship together.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Group B of the file-only decode, measured on DL2 2026-11-03:
- Frequency = (sample rate / 2) / half-period: 527,915 / 527,915 cells
at 1024 sps and 1,725 / 1,725 at 2048. #50: half_period_to_hz took a
fixed 512 and halved every 2048-sps frequency; it now takes the rate
(default 1024). Blastware prints 'N/A' for a half-period of 0, '>100'
('>200' at 2048) at 5 samples or fewer, '<1.0' below 1 Hz.
- Each interval's vector sum, sqrt(PVS^2) at the event's range:
771,354 / 771,354.
- Interval size: uint16 seconds at k - 40 (Series IV [8:10]).
- Stop: the footer's (2,995 / 2,999 sampled; 4 print a second earlier).
Event gains histogram_interval_sec, interval_half_periods, interval_pvs
and stop_time; the .h5 gains /intervals/half_period/<ch>,
/intervals/pvs_ips and a histogram_interval_sec attr. The decoder walks
a histogram once (histogram_codec.channels_from_records) and takes the
event's PVS from the same records. The checker compares each interval
column, number or Blastware's word; the test that pinned Tran Freq Hz
as blank now pins the match.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Brings be5bab4 and its history from the decode checker's branch: a Blastware
file's job number; decode_blastware_bytes choosing the codec by STRT[18] and the
histogram layout check by peak <= PVS <= sqrt(3) peak; the footer as the file's
last 26 bytes (no day-late histograms); docs (reference Appendix D.6, the
file-only status).
Conflicts, both kept whole:
- CLAUDE.md: this branch's 'Narrowed 2026-10-26' 5A block stays, followed by
dev's 'Open, not blocking' line (the 8x sensitive-range item struck out --
resolved by the file's range).
- docs/instantel_protocol_reference.md (CRLF, byte-safe): the change-log rows in
date order -- dev's 2026-11-03 and 2026-11-02, this branch's 2026-11-03
(call home), 2026-10-29 and 2026-10-27 (#46, this branch only).
Suite on the merged tree: 1399 passed, the 16 known failures.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- The page's top bar Firmware read '—' for a Micromate: Batch 2 gave the Device
tab's card firmwareLabel() but not populateDeviceBar. Seen at the bench
2026-11-03; checked in jsdom ('—' before, 'Thor line (version not read)' after).
- save_imported_bw's overlay comment said the waveform codec was undecoded and
gave +-10 in/s; the overlay now stays because production keeps a paired
Blastware report as the record until the file-only decode has no blanks
(flagged by the decode-checker session). Comment only.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Measured at the bench 2026-11-03 (UM20147): monitoring, a Micromate returns its
real call-home block and ACKS a call-home write, but does not apply it -- three
read-backs unchanged, and its own menu says 'Feature disabled while monitoring'.
SFM now refuses up front (UnitStateUnknown, 409: '... is monitoring -- a Micromate
ignores call-home changes while monitoring ...; stop monitoring first -- nothing
sent'), dry run included, instead of sending a write the unit ignores.
And the block must be the call-home block: micromate.writes.is_call_home_content
checks its header is its own length (00 7C, N = 124 -- 00 7C DC on every read,
UM12947 and UM20147). plan_call_home_enabled refuses any other 126 bytes, the
change refuses before sending, and call_home_state says why (enabled = None).
At the bench this was checked by eye before the monitoring write.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Measured at the bench 2026-11-03 (BE9441): while monitoring, a MiniMate answers
the 0x2C call-home read with its DEVICE-INFO block ('Instantel', 'MiniMate Plus',
its serial) -- as it answers 1A -- and idle again, minutes later, the call-home
block. SFM writes back only a block it just read, so a monitoring MiniMate's
call-home cannot be changed; the change core already refused (byte 5 read as
'unknown(0x6E)', nothing sent), but said so cryptically.
- minimateplus.protocol.is_call_home_block(raw): the block starts with its own
length 0x7C and is N (or N + 2) bytes unescaped; the device-info block fails it.
- The Series-3 change raises UnitStateUnknown (409) with 'did not return its
call-home settings -- a MiniMate answers the call-home read with its
device-info block while monitoring; stop monitoring first ... nothing sent',
for a dry run too. call_home_state returns enabled = None with that reason.
- The page's callHomeRows shows the reason in place of 'Unknown (byte 5 = ...)'.
A blind write while monitoring stays untested on purpose.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Group A of the file-only decode, every field matched against every DL2
report (2026-11-03):
- Identity block before the setup name, what the live read gets from
SUB FE: serial k-202, firmware k-147, DSP version k-138, calibration
date k-132 + 'by' k-128, manufacturer k-94, model k-72, firmware
minor k-193. Event.device_info (DeviceInfo gains calibration_date /
calibrated_by). Serial, Version and Calibration 69,983 / 69,983.
- Battery: uint16 hundredths of a volt at k-190 (Event.battery_volts).
69,729 exact; the other 254 are Blastware rounding half up.
- Trigger source: the two bytes between the embedded event record's
lead and fe 80, a bitmask (0x01 Tran 0x02 Vert 0x04 Long 0x08 MicL
0x200 Manual): 6,493 / 6,493. Event.triggered_by.
- Trigger settings in Series IV's 0x1A layout: sources bitmask k-19,
stop mode k-31 (0 = Fixed), each channel's float32 level at
label+30 (geo in/s, mic psi), mic type code at MicL+4 (2 = Linear
Weighting). Geo level 6,447 / 6,447, mic 4,403 / 4,403; Blastware
prints a level when its channel is a trigger source and the event
was not Manual. The mic level's dB uses 6895 Pa/psi (4,272 / 4,272
against 4,271 at 6894.757).
- .h5 attrs for all of them (additive).
- Checker: SFM's side reports the ten fields; the mic trigger level
follows the report's dB/psi. Carve-out
units-is-a-display-preference: dB or psi is Blastware's PC setting
when it wrote the report -- DL2's reports switch fleet-wide in 61
clean runs by write time, and no byte of the file separates them.
Two tests that pinned BatteryLevel / Calibration as blank now pin the
match.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
- s4_change_call_home's read_state now returns an unknown(0xNN) run state as
it is, so the change core refuses it (UnitStateUnknown, nothing sent), as
start/stop already does; it checked only for calling_home.
- run_change records the snapshot on the lost-ack path too: after an ack is
lost, what the unit now holds (and, on Series 4, whether [118:120] moved) is
what tells whether the write landed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
call_home_image returns the unescaped N + 2 image, but the send path handed it
to write_call_home_config, whose write_image unescapes again -- and unescaping
is not idempotent: a real 0x10 before 02/03/04 loses its 0x10. A call-in time
of 16:02-16:04 (hour 0x10) is exactly that. One such time made the send refuse
before the wire yet audited as 'sent, acknowledgement lost'; two made it send a
block shifted by two bytes from [101] (num_retries and the time fields wrong).
The Blastware-frame test could not see it: it checked the image builder, not
the bytes the protocol framed.
- MiniMateProtocol.write_call_home_image(image) frames a built image once
(0x7E, ack 0x81, 0x7F, ack 0x80), raising ImageRefused before any byte when
it is not a whole block; write_call_home_config (the legacy multi-field path)
is write_image once + that. Its stale 127-byte docstring is gone.
- MiniMateClient.write_call_home_image uses it.
- The Series-3 change passes is_refusal=ImageRefused, so a pre-wire refusal is
audited as nothing sent (sent = 0), not as a lost ack.
Tests drive the real client -> protocol over a stub answering with BE11529's
recorded acks: the unit's own read, a 16:02 time, and 16:03 + 16:04 all go out
exactly as built; a short image is refused with nothing written.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
device_routing.js (Node-tested): call_home_state / call_home_on / call_home_off
routes (serial required); controlsFor gains callHomeChange (by serial, a
confirmed Series 3 or 4) and callHomeRead now covers a Series 4 by serial;
serialPanes gains callHomeForm / callHomeBox; callHomeRows renders the switch
(On / Off / 'Unknown (byte 5 = 0xNN)'), dial string and series;
changeErrorText takes the whole label ('Start monitoring', 'Enable call-home').
sfm_webapp.js: by serial the Call Home tab hides the legacy multi-field form
(Series 3 by host only) and shows the unit's switch with On / Off. Each asks
confirm(), sends one audited change, reports it with changeSummary /
changeErrorText, then re-reads quietly so the change's own result stays on
screen. A different unit's switch is never left showing. The new buttons are
wired with addEventListener, not onclick= (no inline JS).
Checked in jsdom against the real page: placeholder, read, Off (confirm, the
disable route, 'confirmed -- enabled -> disabled'), a serial edit clearing it,
legacy mode unchanged, no script errors.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- DeviceAccess.call_home_state (a read) and set_call_home (change=True: never
retried, audit required for a live change, dry run without one), routed by
series like start/stop. A config write is read back on its own window: up
to 3 reads, 1 s apart, not the monitoring one.
- Routes, serial required (422 without), all three serial-aware: the state as
a dict; enable / disable through _change_response, so their statuses are
start/stop's and an unconfirmed change carries sent + audit_id. The legacy
GET / POST /device/call_home are unchanged (a Micromate serial is still
refused there, 501).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Ground truth: Blastware changing BE11529's call-home settings on 2026-04-20
(Remote Access -> Setup Unit), paired raw files of what it sent and what the
unit answered: the read, the enable (read 0x00 -> wrote 0x01), the disable
(read 0x01 -> wrote 0x00). From the unit's own read before each write, SFM's
0x7E frame (call_home_image + build_bw_write_frame) is Blastware's byte for
byte -- nothing but byte 5 differs from the read -- and the 0x7F confirm too.
Mutation-checked: inverting the byte SFM writes fails the test.
S3_CALL_HOME_FRAME_VERIFIED is now True; the gate stays tested shut by
monkeypatch, and a test pins that its comment names this proof.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- minimateplus.protocol: call_home_enabled(raw) reads byte 5 of the UNESCAPED
0x2C payload (0x01 on / 0x00 off, measured 2026-04-20; anything else None --
bench finding #1's lesson: an escaped byte before it would move the raw
index); call_home_image(raw, enabled) is write_image's N + 2 image with byte 5
set and everything else as read, refusing a byte 5 never measured.
- MiniMateClient.read_call_home_raw() / write_call_home_image(image) (0x7E then
0x7F, each ack checked, never retried).
- Series3Adapter.call_home_state (wake, then 0x2C; no serial read, like status)
and change_call_home: the shared change core with a connect() identity check,
state 'enabled' / 'disabled' / 'unknown(0xNN)' (unknown sends nothing), the
plan showing both exact frames, a snapshot of both unescaped images.
- S3_CALL_HOME_FRAME_VERIFIED = False: a live change is refused (501) before any
connection until the frame is reproduced from Blastware's (next commit).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- micromate: ENABLEABLE_WRITES gains 0x7E/0x7F (the call-home write and its
confirm; spec row 9, enable/disable only); MicromateClient.get_call_home_content()
returns the 126-byte 0x2C content.
- sfm/device_access: CallHomeState (serial, series, enabled, dial_string, detail
with byte5 and the whole block); s4_call_home_state reads bit 0 of [5] and the
dial string at [6:46]; s4_change_call_home runs the shared change core with
micromate.writes.plan_call_home_enabled -- built from the read run_change made
just before, and that same plan is the one sent. A unit calling home (run
state 0x03) is refused, nothing sent. The read-back judges the edited bit
only; the snapshot records both blocks and every changed offset -- [118:120]
is unit-maintained and always moves.
- The write-ceiling tests take 0x71 (the setup write, phase 5) as their
over-the-ceiling example now that 0x7E is enableable.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
run_change named its change and its target state from a start/stop bool. A
ChangeKind (action, want, became) now says what the change is called and which
state read back means it took; monitoring_change(start) gives exactly today's
names, call_home_change(enabled) the new ones. An optional snapshot hook
records what the unit holds after the change in the result and the audit row
(never the verdict; one that raises is recorded as its error).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- #6 Config tab by serial: the empty legacy edit form stays hidden (settings
are read-only until phase 5); the settings box shows from the start, 'Not read
yet', and a different unit's settings are never left on screen.
- #10 A start/stop that went out but was not confirmed is no longer called
'failed'. The route now adds 'sent' (acknowledged / unknown) and 'audit_id'
to a ChangeUnconfirmed -- same status, same message -- and the page says
'Start monitoring not confirmed: <what happened, audit record>'.
- #12 Device tab by serial: the empty legacy Compliance/Project tables are
hidden behind a pointer to the Config tab; a Micromate's Firmware card reads
'Thor line (version not read)' (its version string is in 0x01, undecoded).
- #16 A 504 with nothing sent adds: the connection opened, so the modem is
reachable -- another program (THOR or Blastware) may be holding the line, or
the unit is busy. Measured 2026-10-29: THOR polling leaves SFM a 0-byte 504.
New logic lives in sfm/static/device_routing.js (firmwareLabel,
deviceErrorText, changeErrorText, serialPanes) under Node tests; the page glue
in sfm_webapp.js only applies them. Checked in jsdom against the real page
(served at a fake origin, /static from disk): all four, legacy mode unchanged,
no script errors.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Stack-wide rule since 2026-11-02 (terra-view docs/tmi-stack.md, Terra-View's
rule 4): no inline JavaScript, because a test cannot load it. This page's tests
had to regex their code out of the HTML. Batch 2 edits both of the page's
scripts, so they come out first, verbatim:
- sfm/static/device_routing.js: the tested routing rules (157 lines)
- sfm/static/sfm_webapp.js: the rest of the page (2,274 lines)
The page loads them with <script src="static/..."> where the inline scripts
were, so load order and the onclick handlers are unchanged. Verified: putting
the files back inside those tags reproduces the old sfm_webapp.html byte for
byte, and a jsdom page check (served at http://sfm.local/, /static from disk,
no network) gives identical output before and after.
The server serves sfm/static/ at /static/, with Cache-Control: no-cache so a
browser revalidates (a cheap 304) and a new SFM never runs a cached old
script. Opened from disk, the page needs its static/ folder beside it.
Tests: the routing tests load the file instead of regexing the HTML; new
test_webapp_static pins no inline <script> in the page and the /static route
(through the whole app, middleware included).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
The setup block has Series IV's 0x1A layout here too: report flags at
k - 9 (bit 0x02 = job number shown) and the number, uint16 BE, at k - 8,
kept while switched off. The flag matches Blastware's JobNumber on
2,997 / 2,997 DL2 events that print one and 66,986 / 66,986 that don't.
Every printed value is 1 and matches; hidden ones hold real numbers
(802, 1012, 1013, 622), so the value is only proven for 1.
- ProjectInfo.job_number_enabled / job_number, named as in
micromate.setup_block.
- write_event_hdf5 stores both as .h5 attrs when read (additive).
- The checker reports the number only when shown, and scores a number
only SFM shows as a mismatch. The old test that pinned JobNumber as
sfm_blank now checks only the ZC cases it also covered.
Not carried into the DB, the API or the PDF report yet (needs a column).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
With the decode checker's fixes merged (histogram vector sum 625bc39, mic psi
5644dbd, the file's geophone range 4844135), the event file reads everything
Blastware reports. So a live download's row and samples are now the file's:
peaks, vector sum, mic -- and the geophone range from the file's own setup
block, the setting when the event was recorded. The live 1A is the unit's
setting now, which may have changed since; it is the fallback only when the
file's range does not read.
Measured: K557J1KB.RQ0W (Sensitive waveform) downloaded with its settings unread
-- e.g. while monitoring -- stores 0.019 / 0.055 / 0.019 and PVS 0.061,
Blastware's report; its .h5 read 0.155 / 0.44 (8x) before. M010HR6K.OA0H
(Sensitive histogram) likewise. K441LTON.900 (Normal) stores Blastware's
values whatever the unit's current settings say, and its mic is 5.80e-4 psi
(Blastware: 106.0 dB(L)).
The unit's 0C summary stays the download check, and fills in the channel peaks
and vector sum only when the file's range does not read (never seen in DL2) and
the unit is not confirmed Normal -- the impossible-vector-sum guard kept there.
The mic is the file's always. Closes the range part of open finding #17.
Store consequence: new live downloads only; no backfill, no migration.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Brings 057df47 (fix 4844135, changelog be58b4f) from the decode checker's branch
-- Event.geo_range from the file's setup channel block (label+29: 0 Normal,
1 Sensitive, None not read), peaks and histogram PVS scaled by it,
write_event_hdf5(geo_range=None) using it -- and dev's v0.33.0 release commit
(6c7c6b0).
Conflicts, resolved as agreed with the decode session:
- sfm/waveform_store.py save_imported_bw: dev dropped the forced
geo_range="normal"; this branch keeps its geo_range parameter, now
Optional, default None -- an import uses the file's own range, an explicit
value (a live download's) still wins.
- CLAUDE.md: dev's newer 'Where things stand (updated 2026-11-01)' date.
Measured on the merged tree: K557J1KB.RQ0W (Sensitive waveform) decodes
0.019 / 0.055 / 0.019, PVS 0.061 -- Blastware's report -- and its imported
.h5 peaks 0.0194 / 0.055 / 0.0194 (forcing 'normal' gives 8x: 0.155 / 0.44).
M010HR6K.OA0H (Sensitive histogram) likewise. The live path still passes the
unit's 1A range or 'normal' when unread -- unchanged by this merge.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
In the setup's channel blocks, the byte 29 after each geophone label is
the range: 0x00 Normal (10 in/s), 0x01 Sensitive (1.25 in/s). It matches
Blastware's GeoRange on 70,042 / 70,042 DL2 events, all three channels
agreeing on every one (35 Sensitive). SFM's live 1A has the same byte
at label+33. SFM assumed Normal, so every Sensitive event's peaks,
vector sum and .h5 samples read 8x high.
- Event.geo_range (0 / 1, None when not read -- channels disagreeing,
an unknown value or a missing block -- with a decode_problems entry).
- decode_blastware_bytes scales peaks and the histogram vector sum by it.
- event_hdf5.write_event_hdf5: geo_range defaults to None = the event's
own, else Normal; an explicit argument still wins.
- waveform_store.save_imported_bw and scripts/backfill_sidecars.py stop
forcing 'normal', so imports and the backfill store the file's range.
The waveform_store line was agreed with the parity session, which owns
that file; its own branch keeps a geo_range parameter, defaulting to
None at its next dev merge.
- The checker's SFM side converts at the event's range and reports
GeoRange; tests that pinned the old 8x gap now pin the fix, and the
saturation carve-out is still tested against an 8x value.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Since the decode checker's histogram-PVS fix (625bc39, merged 6945009) the file
reads a histogram's vector sum as the unit stored it: K441LTON.900 stores
0.200 / 0.385 / 0.255 and a vector sum of 0.3852, as Blastware's report (was
0.503). The 0C summary, read at fixed offsets, can shift (BE9441 read 0 and
-0.0, bench #4) -- and a shifted value can look plausible and pass the
impossible-value guard. So the row now takes the file's channel peaks and
vector sum.
Only when the unit's settings confirm Normal range: the file reader computes
every peak as if the range were Normal (_GEO_SENSITIVE_FS_INS is defined but
unused), so a Sensitive unit's file peaks are 8x off (the checker's 33
waveforms). For Sensitive, or a range not read (a monitoring unit's 1A has no
settings), the unit's own peaks stand, as before. The mic is always the
unit's: the file still reads it as 0. The 0C peaks remain the download check.
Store consequence: new live downloads only; no backfill, no migration.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Blastware names a direct download K441LTON.900 and only its call-in copy
K441LTON.900H, so a folder of directly downloaded events cannot be sorted by
kind. SFM's own files now always carry the letter. It is read from the file's
own record-type byte (STRT[18], #41) by the new with_type_letter() -- not from
the recording mode: BE9441's K441LTOK.R10 is a waveform that triggered 2 s into
histogram K441LTOK.QZ0 (Histogram+Continuous). A file whose type does not read
keeps the plain name; a name never fails a download.
All three paths that name a MiniMate file SFM builds: the device-access
download (the page's event list), WaveformStore.save (the legacy route's store
copy, the bench call-in server), and the legacy /device/event/{i}/blastware_file
download. Verified on BE9441's recorded 5A walk: 0111f210 -> K441LTON.900H,
011106a0 -> K441LTOK.R10W, byte-identical to Blastware's files.
find_event_by_blastware_name tightens with it: a lettered name matches itself
and the letterless form, not the other letter (a waveform and a histogram in the
same second are different events); a letterless name still matches all three.
Store consequence: new downloads only; rows and files stored before keep their
names, and 'already stored' still finds them. No schema change, no migration.
The event list shows the plain name until the event is downloaded (the type is
not known before the 5A).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
persist_download checked 'already stored' on the unit's 0C time only, but a
histogram's row is stored at its file's time, a second earlier on most
histograms (#51): K441LTOK.QZ0 decodes to 16:06:34, its 0C says 16:06:35. So a
live download of an event the watcher had imported missed the check and
re-stored it -- UPSERTing over the watcher's row (Blastware's ZC frequencies and
vector sum lost) and rewriting its sidecar as sfm-live -- and every repeat live
download rewrote the files again.
New SeismoDb.find_event_by_blastware_name(): the row stored under the same
Blastware name (the event's second, per blastware_filename_time; the rule
_restamp_by_file uses), matching a direct name to the call-in copy's W/H name.
Any other name matches nothing. Also two comments from 9492e49 that said the
opposite of the code (the unit's peaks are overlaid; source.kind is a parameter).
Store consequence: none for existing rows; no schema change, no migration.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
The reconnect in ce441a0 opened a fresh connection and sent a bare 0x15 (the
identity check) before any SESSION_RESET + POLL. It exists for a unit that has
just started -- sensor check, then monitoring -- and a monitoring MiniMate
ignores a bare request until woken (measured 2026-04-08), so the identity read
would have timed out and the start reported unconfirmed anyway. Now: open,
wake (the same retried wake the read-back uses), read the serial, read 0x1C --
the order the status read and the legacy write routes use. Still one
reconnect, TCP only, nothing re-sent.
The fake gains bare_requests_ignored (off unless a test asks): a fresh
connection's reads time out, with the real client's TimeoutError, until woken.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
A live Series-3 download was stored from the live 5A decode (store.save): a
histogram got no samples and nothing to plot (bench 2026-10-29). The download
now carries the assembled Blastware file (DownloadedEvent.bw_bytes, built by the
new blastware_file_bytes -- byte-identical to Blastware's own K441LTON.900 and
K441LTOK.R10), and persist_download stores it through save_imported_bw, the
path the watcher uses for Blastware's files, the way Series 4 already uses
save_imported_idf. The event is decoded from the file: histogram samples,
setup-block sample rate and record time (#44/#45). source.kind is 'sfm-live'.
The file path does not yet read three things right (measured on BE9441): a
histogram's vector sum (0.503 where Blastware and the unit say 0.385 -- the
decode checker's open finding), the mic peak (0), and a sensitive range. So the
unit's own 0C channel peaks, mic and vector sum are overlaid, as Series 4 does,
except an impossible vector sum (below the largest channel; BE9441's 0C read
-0.0, bench #4), and the unit's range is passed through for the stored samples.
Store consequence: new live MiniMate downloads only; existing rows and files are
untouched; no backfill, no migration. The record type still reads 'Waveform'
for a live histogram until #41 (record type from STRT[18]) lands from the decode
checker's branch.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
BE9441 over a modem, 2026-10-29: the start was acked, but the modem closed the
line during the ~30 s sensor check, so the read-back's first wake hit
'[Errno 32] Broken pipe' and the change was reported 503 'not checked' although
the unit was monitoring. On an OSError in the read-back, a TCP unit is now
reconnected once, its serial checked against the named unit, and its state read.
Nothing is re-sent: the start still goes out exactly once. A serial cable is
never reconnected (opening a MiniMate's port reboots it), a second failure or a
silence (a cleanly closed line) ends 'not checked' as before, and a different
unit after the reconnect is refused (409, change unconfirmed).
Store consequence: none.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Brings the branch up to dev (41 commits) before the 1c bench fixes, which
touch code dev changed: the histogram reader (#47/#49, bench finding #2), the
v0.32.0 event-time rules, the Blastware file's setup-block fields (#44/#45),
and the decode checker for verifying stored S3 downloads.
One conflict: the top of the Series-III reference's change table -- both sides
added rows; kept all, in date order, CRLF preserved. CLAUDE.md, README,
blastware_file.py, models.py and database.py merged cleanly. Suite: the known
16 failures only (15 test_bw_ascii_report, test_save_imported_bw_without_report_
works_unchanged, which also fails on dev); 1237 passed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
GET /device/monitor/status?serial=UM...&run_state=true adds
detail.run_state = {code, name}. For the ring-path bench test: the code
during and after a call-home (0x01 for ~18 s after a stop, inferred to be
call-home attempts; 0x03 = calling home) is what the test watches. Opt-in
because it is one more round trip (~0.65 s on cellular); a plain status read
is unchanged. Series 3 has no 0x49 and ignores it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- The arrow keys reached the legacy per-index waveform route in serial mode,
even with no list loaded (an unlocked MiniMate chain walk + 5A on the same
modem session). perIndexLive() is now the one rule for the per-index
buttons, the chips and the keyboard: live only for a list loaded without a
serial that has events.
- A failed reconnect left the previous unit's confirmation live (badge,
Diagnostics incl. the unguarded blind/slow-drip stops, call-home read).
connectUnit() now drops it before it identifies; only this answer confirms.
- Unit strings reached innerHTML: the Device tab's cards (active_setup, new in
1c) and its compliance/project tables now render as text, and Diagnostics'
error spans go through escapeHtml().
- CLAUDE.md: the ring-path Runs A/B are a merge gate (the spec's prerequisite
to a webapp sending serial), not only a use-time one.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Task 3's brief asked for them and they were missed: with a serial, the panel
now shows UnitStatus.device_time and event_count, "—" where null (Series 3
reports both as null). Without a serial the two fields stay hidden.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- Config, with a serial: Read shows the unit's shared UnitSettings (setup,
record mode, sample rate, record time, histogram interval, geo trigger,
notes; — for null) in place of the write form. settingsRows() is in the
device-routing block, Node-tested; the rows are rendered as text, since
setup names and notes come from the unit.
- Write stays off for both series (and without a serial), tooltip
"Coming in phase 5 (#46)"; Call Home write likewise, "Coming in phase 4".
- Call Home read follows controlsFor().callHomeRead; for a confirmed Series 4
the tab says "Not yet available for Series 4".
- Diagnostics: every button follows controlsFor().diagnostics (Task 3), and a
refresh for anything but a confirmed Series-3 unit sends nothing and says
why. Its requests carry the typed serial, so the server guard checks it.
- Without a serial the legacy reads are unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- With a serial, Start / Stop ask first ("Start monitoring on BE9441?"), then
POST once to the audited change -- never retried; both buttons stay off while
it is in flight, so a double click cannot send twice.
- The status bar shows changeSummary() of the ChangeResult, on a 409/502 too
(dry run, already-in-state, confirmed a -> b, or the outcome and read-back);
an error without one shows its detail verbatim; no reply from SFM says the
command may have been sent and where to look, rather than that nothing was.
- Then one status read updates the panel. The legacy 5 s confirm poll is not
used in serial mode; with a blank serial start/stop are unchanged.
- Diagnostics' Stop, which goes the same way in serial mode, shows the same
summary; deviceFetch errors carry it for any non-200 ChangeResult.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- Load events with a serial lists the shared EventRef shape as a table: index,
time, type, PVS and the three peaks (or —), each row with its own Download.
- Download POSTs the row's event_id; SFM checks and stores it. The status bar
says what was stored (or that it already was), and the stored event opens
in the viewer. A refusal shows the server's detail verbatim.
- eventView() (device-routing block, Node-tested) reads both event shapes for
the table, the chips and the peaks bar.
- A list loaded without a serial keeps the chips and the per-index Load /
Save / Download buttons, unchanged; for a serial-loaded list those buttons
are off with a tooltip pointing at the rows.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- A Serial field beside host/port. With one, the Live tabs use the serial-based
endpoints (both series); without, every read behaves as before.
- The series badge, Hang up (Series 4), Diagnostics (Series 3), call-home read and
the disabled config/call-home writes all follow applyControls() <- controlsFor()
on the unit's own /device/info answer; editing the serial, host or port drops
the confirmation. Erase additionally needs a confirmed Series 3.
- Every /device/ request goes through deviceRequest/deviceFetch <- deviceUrl
(a static test enforces it); the legacy per-event routes joined deviceUrl
(event_waveform / event_file, index in the path).
- The status panel and Device tab read both shapes (shared and legacy).
- In serial mode the connect skips the legacy storage_range read (one connection
fewer; a Micromate has no such route). Start/stop without a serial behave as
before; with one, only for a confirmed series.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
One block of sfm_webapp.html (/* <device-routing> */) holds every rule that
decides where a /device/ request goes or whether a series-specific control is
live: seriesFromSerial, unitQuery, deviceUrl, confirmedSeries, controlsFor,
changeSummary, downloadSummary. No DOM, no fetch, so the tests run it in Node.
The safety rules it pins: a control follows the unit's own /device/info answer,
never a typed serial alone, and stops counting when the serial is edited;
Diagnostics only for a confirmed Series 3, Hang up only for Series 4; config and
call-home writes off for both series until phases 4-5. Also a test that the
page's inline scripts parse together (shared global scope).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
0xA2 is CONFIRM ERASE on a MiniMate and ends a call-home on a Micromate, and the
legacy host/port routes had no identity check: only the MiniMate parser's
inability to read a Micromate's replies stood between Diagnostics' Erase and a
Micromate (phase 1c safeguard, agreed with Brian 2026-10-28).
_require_series3(unit_serial, expected) refuses (409, 'nothing sent') unless the
unit's own serial is Series 3 and, when ?serial= names one, that one:
- POST /device/config (+ /config/project) and /device/events/erase: the serial
connect() already reads -- no extra request;
- /device/rescue (when it writes call-home or erases) and POST /device/call_home:
one SUB 0x15 read (new MiniMateClient.read_serial).
Exempt, with the reason in a comment: legacy monitor start/stop, blind stop, slow
drip, spam -- 0x96/0x97 mean the same on both series (measured), and the rescue
tools must reach a unit too wedged to answer.
Tests: each guarded route refuses a unit answering UM20147 and a different BE
unit with no write call, proceeds for the named unit (normalised), reuses
connect()'s serial where it has one; the blind stop builds no client;
read_serial decodes BE9441's recorded 0x15 reply.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Brian: keep an event whose time is only an estimate (no validated embedded
event record) -- never discard a measurement for want of an exact timestamp --
but it must not silently cause an overwrite, merge or dedup collision.
insert_events, for timestamp_source 'estimate' (_estimate_guard):
- never restamps (moves) a row;
- if its file (a Blastware name) is already stored under another time, writes
nothing -- no second row, the stored time kept;
- if a different event already holds that second, writes nothing -- the old
upsert would have written this event over that one;
- otherwise stores it, or refreshes its own row at the same second, as before.
Each refusal is a WARNING naming both sides; the file and sidecar (which says
'estimate' and carries the decode problem) are already in the store. A generic
upload name ('imported.bw') is not taken as identity.
Tests: each rule, an estimate on a free second kept, generic names, and an
import end to end (a corrupted record next to a different event's second).
3 mutants, each caught. Suite vs clean origin/dev: the same 16 failing tests,
failure reasons byte-identical; 582 passed vs 553.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
Second start through SFM, BE9441 2026-10-26 23:54:41: acked 0x69, and Brian saw
'starting, performing sensor check, recording' -- but the read-back's single
SESSION_RESET + POLL went out 2.3 s after the ack, inside the ~30 s sensor
check, and was never answered or re-sent (504 after 120 s, audit ca7b5b42).
Brian: every unit is set to sensor-check before monitoring, ~30 s, then
'Recording...'.
- MiniMateProtocol.wake(attempt_s, deadline_s): SESSION_RESET + POLL re-sent
every attempt_s until the unit answers, then the POLL data step; a named
timeout at the deadline. Reads only. MiniMateClient.wake() wraps it.
- The Series-3 change: after a START, the first read waits S3_SENSOR_CHECK_S
(30 s) before asking; every read then wakes with retries (every 5 s, up to
60 s). A stop is unchanged -- its read-back was confirmed three times tonight.
Tests: a unit deaf for 4 probes is asked a 5th time and answers; a unit that
never answers ends in the named timeout after ~6 probes; a start's first read
waits the sensor check, a stop's does not; every read is preceded by a wake.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Brian's requirements: the instrument's data is the only time source; a filename
is a cross-check, never a fallback (an event SFM receives itself has none).
The record (found by reading a seismo_lab Inspector dump; Series-III reference
§7.8.9): 00 28 05 00 ?? ?? | fe 80 | trigger | stop, times dd mm yyyy(BE) 00 hh
mm ss. Measured on 7,935 waveforms (DL2 + prod store): exactly one candidate
validates in every file; trigger = Blastware's report 1,320/1,320, = filename
7,935/7,935, = the unit's 0C record 10/10.
Provenance (requirement 6, measured): in Blastware's download of 8 BE9441
events the record -- with 24 B before and 22 after -- occurs exactly once in the
unit's own A5 reply payloads; SFM-only downloads (no Blastware) carry it too.
It is instrument data, not Blastware's.
- _embedded_event_record(): every fe 80 before the footer is a candidate; it
counts only with the lead bytes, two well-formed times (zero byte zero),
footer ts1 <= trigger <= stop, stop = footer ts2 or a second before, and a
length matching the record time. Exactly one must count; none or several is
a decode problem, never a guess.
- Without one: the footer estimate, timestamp_source 'estimate', a
decode_problems entry, a WARNING. No filename fallback.
- A filename that disagrees is logged; the decoded time is kept. A paired
report fills in only without a validated record (apply_report_to_event, the
sidecar dict overlay, event_to_sidecar_dict) and is logged when it disagrees.
- decode_blastware_bytes(raw, name=None): no file or name needed;
save_imported_bw uses it (no temp file). Event gains timestamp_source and
decode_problems; the sidecar records both.
- Histograms unchanged (#51): their record (fe f5) is noted, not used.
Tests: raw bytes with no name (ZI0, 7 BE12844 oracles), a disagreeing name, each
validation rule alone, two valid candidates, no filename fallback, report
precedence, sidecar. 7 mutants, each caught. Real data, decoded with no name:
7,961/7,961 waveforms on the record, 0 disagreements with filename or report;
10,433/10,433 prod histograms unchanged. Suite: only the 16 known failures.
Open (reported, not changed): 3 DL2 files named as waveforms whose body the
waveform codec does not recognise keep the footer start, 4 s off, as on dev.
None in prod.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
BE9441, 2026-10-26 23:41:48 (through the bridge): SFM's start (0x96, Blastware's
own bytes) was acked 0x69 and the unit began monitoring -- Brian saw it -- but
the read-back sent one bare 0x1C two seconds later and got nothing for 120 s,
so the change reported 'sent and acknowledged, but reading the state back
failed' (504, audit 0c1cf813). Nothing was retried.
A monitoring MiniMate ignores a bare request until SESSION_RESET + POLL
(measured 2026-04-08). The read-back had relied on the connect's wake; a stop's
read-back (18:53, the unit idle by then) never needed it. Every state read in
the change now goes through _woken_state: client.poll() (41 03, POLL, 41 03,
POLL -- the connect's own sequence), then 0x1C.
Test: after the send, every 0x1C read is preceded by a POLL. No codec, store or
DB change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44