Author SHA1 Message Date
serversdownandClaude Opus 5.5 8d5c16b03b docs: the unit's own event summary (reference D.6.12), and group D in CLAUDE.md
- Reference D.6.12 (new): the record chain after the embedded event
  record, the per-channel summary layout, what Blastware prints from it,
  why recomputing failed, and the two odd 2019 files.  Group D part 1
  (time of peak, acceleration with the fitted g) is documented there too.
- Reference §7.8.9: its "constant, meaning unknown" bytes amended in
  place (the vector-sum peak sample, then the next record's lead).
- Reference D.6.11 and CLAUDE.md: 59 of 88 report fields match on every
  DL2 event (run 20261105-140021, 0 regressions; 47 before group D).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-05 14:25:31 -05:00
serversdownandClaude Opus 5.5 3564c4a744 docs: phase 5 benched on both series (2026-11-04)
Both protocol references, the spec's bench section and CLAUDE.md record
the bench: every settings change acknowledged, read back and confirmed on
the unit's screen, both units restored byte for byte; the escaped-
checksum stray byte (fixed); a MiniMate's open setup menu writes its
whole-block copy back on Cancel or Save, losing a remote change; the
alarm write at channel +38; [26:28] re-set by the unit while monitoring;
the first Micromate setup push with the unit's CRC equal to SFM's; the
Micromate scheduler switch in none of the blocks SFM reads.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-04 16:16:40 -05:00
serversdownandClaude Opus 5.5 f24913189b merge: dev 9b458b5 into the parity branch (group A/B, #51 histogram timing)
Brings the checker's file-only decode work onto the parity branch so the
phase-5 bench runs on the code that will ship.  One conflict, the CRLF
Series-III reference changelog: both kept, phase 5's row numbered
'2026-11-03 (5)' above dev's (4)/(3)/(2).  test_event_ingest's live-
histogram dedup test asserted the stored row sits a second off the 0C
time -- the #51 bug, fixed on dev -- so its premise now reads the event's
own second; the dedup it tests still holds.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-04 12:31:21 -05:00
serversdownandClaude Opus 5.5 d4cfb07fce docs: histogram timing from its own event record (D.6.10), and the unit + time + type key
The reference gains D.6.10: the histogram's embedded event record (lead
00 28 05 00, source 04 00, marker fe f5, start, stop) and the interval
and peak-time rules, with 'histograms stay on ts1' retracted in place.
CLAUDE.md 'Where things stand' records the new events key -- any lookup
by event needs the type -- and 47 of 88; the README roadmap follows.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-04 12:19:38 -05:00
serversdownandClaude Opus 5.5 385716d8e1 feat(webapp): edit a unit's settings by serial: preview, send, read back
The Config tab by serial is now the unit's edit form, headed 'On the
unit <serial> -- read HH:MM' and built from the server's editable
fields.  Preview runs a dry run and shows old -> new, notes and anything
that blocks the change; Send (confirm) sends exactly what was previewed,
with its revision, then shows what the unit now holds and re-reads it.
An edit after a preview disables Send until the next preview.  The
by-host form loses its write button; the read stays.  Logic in
device_routing.js (Node-tested), glue in sfm_webapp.js, no inline JS.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:57:17 -05:00
serversdownandClaude Opus 5.5 d0335dbbbd feat(micromate): read the schedule file (read-only)
MicromateProtocol.read_file: 0x94 + path, then 0x48 pages to an
all-zero reply -- THOR's frames byte for byte (UM12947, 2026-09-24),
including params[3] = 1 on 0x94 and params[7] = 1 on the first 0x48.
micromate.schedule parses the 260-byte records (two- and five-entry
schedules from THOR's captures) and names the scheduled starts that
would load a setup other than the active one, ignoring case.  The
client gains the raw (unstripped) active-setup name and the prefs /
trigger / setup content reads a setup push sends back.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:37:30 -05:00
serversdownandClaude Opus 5.5 5ba72740dd feat(codec): one settings codec for both series, on the shared layout
micromate/setup_fields.py: the fields an operator can change (record
mode, sample rate, interval, record time, geophone trigger, Series 3's
range and -- read-only until benched -- alarm, job number and its report
flag, the four notes by slot), the units' own limits from Instantel's
manuals, field-only byte patching (bit fields bit by bit; Series 3's
[26:28] as Blastware writes it; Series 4's CRC recomputed), the
read-back verdict compared by bytes, and the preview revision.

All 11 Blastware compliance writes reproduce from the block before them
(BE11529's first also shows Blastware re-rendering two mic levels
through its dB value; SFM echoes the unit's bytes); Series 4 keypad
fixtures reproduce pairwise.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:33:01 -05:00
serversdownandClaude Opus 5.5 1bb15573fc feat(s3): assemble a settings read into the 2,090-byte block
Unescape each 1A data frame, take data[11:], drop the one non-content
byte that starts every frame but the last: 2,090 bytes headed by
N = 2090, Series IV's 0x1A layout.  Measured on BE9441's 10-26
recording (12 reads, both frame patterns); the read after each
Blastware write equals the image written.  read_compliance_content is
strict (a missing frame raises) and unjudged (a monitoring unit's
device-info answer comes back for the caller to recognise).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 21:28:04 -05:00
serversdownandClaude Opus 5.5 e3a77e421d docs(spec,plan): phase 5 -- the units' own limits, from Instantel's manuals
Brian: use the actual unit limits, not what has been used in the past.
Trigger 0.005-10 in/s in 0.001 steps (capped by the range), record time
1-90 s (Micromate) or the MiniMate manual's 1 MB table by sample rate
(13 s in Histogram Combo), job number 1-9999.  The read-back reports any
value a unit does not take.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 19:30:07 -05:00
serversdownandClaude Opus 5.5 71609e71ab docs(plan): phase 5 -- changing a unit's settings by serial
Seven tasks: the Series 3 read assembly, one settings codec for both
series, the Micromate schedule read, each series' audited change, the
route (and the legacy write retired), and the page.  Spans measured
from 75,958 Blastware reports.  Bench after the final review, Brian's
go per send.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 18:51:53 -05:00
serversdownandClaude Opus 5.5 dba891d504 docs(spec): phase 5 -- the Micromate schedule check; work hours is next
A scheduled start loads the setup it names, so a change to another
setup would be undone at the next start: read schedule.dat and refuse
that case.  Configurable work-hours recording, without THOR's scheduler
or setup files, is the agreed next project.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 18:35:29 -05:00
serversdownandClaude Opus 5.5 2c4ae8c4ef docs: group B in the protocol reference (D.6.9), #50 retracted
Interval size (k - 40), the stop (footer ts2), frequency = (sample rate
/ 2) / half-period with Blastware's words for N/A, >100 / >200 and
<1.0, and each interval's vector sum with its OORANGE rule.  The old
fixed-512 frequency formula is retracted in place.  CLAUDE.md and the
README roadmap follow: 34 of 88.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 18:29:53 -05:00
serversdownandClaude Opus 5.5 0238e4d3f3 docs(spec): phase 5 -- changing a unit's settings by serial
Brian's intent (UM6047's trigger, notes typos, the backup unit), the
flow, the first-version fields, and what is measured: Series 3's
compliance block has Series 4's 0x1A layout; a whole 1A read assembles
to the 2,090 bytes Blastware writes back (exact on both 10-26 writes);
Blastware writes 00 00 at [26:28] and a per-unit constant after the
block.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 18:12:14 -05:00
serversdownandClaude Opus 5.5 8f75be5f72 docs: group A in the protocol reference, and the three meanings of mic 'units'
Protocol reference:
- D.6.8 (new): the identity block (SUB FE's: serial, firmware, DSP version,
  calibration date and 'by', model; battery), the trigger-source bitmask
  in the embedded event record, and the trigger settings (sources, stop
  mode, per-channel levels, mic type) with their DL2 counts.  The
  histogram 'terminal tail' 9c 06 00 42 looks like 9c 06 00 + the
  serial's B (inferred).
- D.6.6: recorded data vs report units vs unit peaks, with the
  MiniMate Plus (s3.9.7) and Blastware (s4) manual sections.  Where the
  unit stores its own Microphone Units is unmeasured; a keypad test is
  proposed.
- D.6.9 (was D.6.7): refreshed, 28 of 88.

CLAUDE.md 'Where things stand' and the README roadmap follow.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 17:24:21 -05:00
serversdownandClaude Opus 5.5 cbce00f8e1 merge: dev into feat/series4-sfm-parity -- the decode checker's file-only fields (job number, codec by STRT[18], last-26-byte footer)
Brings be5bab4 and its history from the decode checker's branch: a Blastware
file's job number; decode_blastware_bytes choosing the codec by STRT[18] and the
histogram layout check by peak <= PVS <= sqrt(3) peak; the footer as the file's
last 26 bytes (no day-late histograms); docs (reference Appendix D.6, the
file-only status).

Conflicts, both kept whole:
- CLAUDE.md: this branch's 'Narrowed 2026-10-26' 5A block stays, followed by
  dev's 'Open, not blocking' line (the 8x sensitive-range item struck out --
  resolved by the file's range).
- docs/instantel_protocol_reference.md (CRLF, byte-safe): the change-log rows in
  date order -- dev's 2026-11-03 and 2026-11-02, this branch's 2026-11-03
  (call home), 2026-10-29 and 2026-10-27 (#46, this branch only).

Suite on the merged tree: 1399 passed, the 16 known failures.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 15:34:59 -05:00
serversdownandClaude Opus 5.5 2e1c2ba21f docs: phase 4 bench -- call-home on/off on both series, idle and monitoring
Benched 2026-11-03 on UM20147 and BE9441 (each on its own modem, one send per
go): idle, a no-op, off and on all acked, read back and confirmed on each unit's
menu; UM20147 accepts 0x00 at [5].  Monitoring, neither series takes a change: a
MiniMate answers 0x2C with its device-info block, a Micromate acks and ignores
('Feature disabled while monitoring').  Series 4 [118:120] is a function of the
block's content -- XOR 0x6D7D per bit-0 flip on two units, not a nonce.  A stop's
call-in reached THOR when the ring followed the ack.  UM20147's clock is an hour
ahead (DST).  Spec, both protocol references (Series III: a CRLF row), CLAUDE.md.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-03 15:32:51 -05:00
serversdownandClaude Opus 5.5 5a089671e8 docs: where file-only decoding stands, and that prod's ASCII overlay is scaffolding
CLAUDE.md 'Where things stand' now says plainly how prod uses a paired
Blastware ASCII report (save_imported_bw overlays its peaks, notes,
sample rate and record time onto SFM's decode), that only report-less
events run on the decoder alone, and that the overlay is scaffolding to
retire at step 3 of the plan.  The checker status is brought up to dev:
18 of 88 fields, the remaining groups A-F in the proposed order.

README roadmap: the same framing and progress.

Protocol reference:
- D.3.3: the footer is the file's last 26 bytes; footer[18:24] is not
  fixed (retracted).
- D.6.1: STRT[18] picks the codec.
- D.6.3: the job number.
- D.6.5: the PVS^2 high word is non-zero above 1.28 in/s (retracted
  'reads 0000'); the peak/PVS consistency check; Blastware's Number of
  Intervals is the monitoring time / the interval.
- D.6.7: refreshed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 13:05:58 -05:00
serversdownandClaude Opus 5.5 e1e8a851c8 docs: where the 1995 default-clock events come from
Brian's account: units come back from calibration with the internal
battery unplugged, so a comms-test trigger before the date is set
carries the default.  DL2 holds 17 such events on 6 units, all within
1995-09-01 12:02 .. 09-03 11:24.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-03 12:12:02 -05:00
serversdownandClaude Opus 5.5 9820a5389f docs(spec): phase 4's final review -- what it caught before the bench
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 17:24:13 -05:00
serversdownandClaude Opus 5.5 3e1d42e04b docs: phase 4 built -- call-home enable/disable by serial; bench questions
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 17:07:36 -05:00
serversdownandClaude Opus 5.5 5b37ea22cc docs(plan): phase 4 -- call-home enable/disable by serial, both series
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 16:47:56 -05:00
serversdownandClaude Opus 5.5 8123d75d72 fix(sfm): page polish from the 1c bench -- #6, #10, #12, #16 (Batch 2)
- #6 Config tab by serial: the empty legacy edit form stays hidden (settings
  are read-only until phase 5); the settings box shows from the start, 'Not read
  yet', and a different unit's settings are never left on screen.
- #10 A start/stop that went out but was not confirmed is no longer called
  'failed'.  The route now adds 'sent' (acknowledged / unknown) and 'audit_id'
  to a ChangeUnconfirmed -- same status, same message -- and the page says
  'Start monitoring not confirmed: <what happened, audit record>'.
- #12 Device tab by serial: the empty legacy Compliance/Project tables are
  hidden behind a pointer to the Config tab; a Micromate's Firmware card reads
  'Thor line (version not read)' (its version string is in 0x01, undecoded).
- #16 A 504 with nothing sent adds: the connection opened, so the modem is
  reachable -- another program (THOR or Blastware) may be holding the line, or
  the unit is busy.  Measured 2026-10-29: THOR polling leaves SFM a 0-byte 504.

New logic lives in sfm/static/device_routing.js (firmwareLabel,
deviceErrorText, changeErrorText, serialPanes) under Node tests; the page glue
in sfm_webapp.js only applies them.  Checked in jsdom against the real page
(served at a fake origin, /static from disk): all four, legacy mode unchanged,
no script errors.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 16:22:22 -05:00
serversdownandClaude Opus 5.5 5bed7d6c6f docs: the file's pre-trigger is the event's, not the setting -- corrects today's #48 note
The pre-trigger float in an event file's setup block varies from event
to event on the same unit, often on the same day (BE18193: -0.25 and
-0.248 on 2026-08-21; 253-256 samples at 1024 sps, -0.002 to -0.249 s
at 4096 sps), and Blastware reports the same per-event value as
Pre-triggerLength.  So it is the event's own pre-trigger, and the note
written earlier today overstated what the files say about #48: the live
1A holds the setting, so a missing anchor in a file says little about
whether the live read loses its anchor.  #48 stays open.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-02 14:23:32 -05:00
serversdownandClaude Opus 5.5 b6e726f850 docs: the event-file fields SFM reads from the file alone (reference Appendix D.6)
New Appendix D.6 records the bytes and DL2 verification for every field
SFM reads from a Blastware event file: record type STRT[18], the
recording-setup block (sample rate k-42, pre-trigger k-36, record time
k-30, the four notes), the geophone range (label+29), each histogram
interval's PVS^2, and the mic scale (0.25 Pa per count, dB offset
81.9384).  None of these were written down outside code and issues.

Retracted in place:
- D.3.1's STRT[20] = record time: it is 00 on 70,041 / 70,041 DL2 files.
- the 2026-08-26 reading of sub-minute histogram records as little-
  endian: big-endian from byte 5 since v0.32.0 (#47/#49), and the
  '2-word tail' is the PVS^2.  Also in CLAUDE.md.

Measured for #48 (files only): the 1A 'stable anchor' be 80 00 00 00 00
is the setup's pre-trigger -0.25 s plus 00 00.  It is present only on
the 3,886 / 6,541 DL2 waveforms recorded at exactly -0.25 s, and on no
histogram.  The live 1A read is still unmeasured.

CLAUDE.md: Where things stand reflects the range fix on dev (6,524 /
6,524 waveforms exact); the 8x sensitive-range item and the MicL dB
item are marked resolved in place.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-11-02 14:03:47 -05:00
serversdownandClaude Opus 5.5 f98c4ff129 fix(sfm): a MiniMate download stores what its own file says, at the range it was recorded at (#17)
With the decode checker's fixes merged (histogram vector sum 625bc39, mic psi
5644dbd, the file's geophone range 4844135), the event file reads everything
Blastware reports.  So a live download's row and samples are now the file's:
peaks, vector sum, mic -- and the geophone range from the file's own setup
block, the setting when the event was recorded.  The live 1A is the unit's
setting now, which may have changed since; it is the fallback only when the
file's range does not read.

Measured: K557J1KB.RQ0W (Sensitive waveform) downloaded with its settings unread
-- e.g. while monitoring -- stores 0.019 / 0.055 / 0.019 and PVS 0.061,
Blastware's report; its .h5 read 0.155 / 0.44 (8x) before.  M010HR6K.OA0H
(Sensitive histogram) likewise.  K441LTON.900 (Normal) stores Blastware's
values whatever the unit's current settings say, and its mic is 5.80e-4 psi
(Blastware: 106.0 dB(L)).

The unit's 0C summary stays the download check, and fills in the channel peaks
and vector sum only when the file's range does not read (never seen in DL2) and
the unit is not confirmed Normal -- the impossible-vector-sum guard kept there.
The mic is the file's always.  Closes the range part of open finding #17.

Store consequence: new live downloads only; no backfill, no migration.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-02 13:48:59 -05:00
serversdownandClaude Opus 5.5 0a87d85202 fix(sfm): a MiniMate download's peaks come from its file when the unit confirms Normal range
Since the decode checker's histogram-PVS fix (625bc39, merged 6945009) the file
reads a histogram's vector sum as the unit stored it: K441LTON.900 stores
0.200 / 0.385 / 0.255 and a vector sum of 0.3852, as Blastware's report (was
0.503).  The 0C summary, read at fixed offsets, can shift (BE9441 read 0 and
-0.0, bench #4) -- and a shifted value can look plausible and pass the
impossible-value guard.  So the row now takes the file's channel peaks and
vector sum.

Only when the unit's settings confirm Normal range: the file reader computes
every peak as if the range were Normal (_GEO_SENSITIVE_FS_INS is defined but
unused), so a Sensitive unit's file peaks are 8x off (the checker's 33
waveforms).  For Sensitive, or a range not read (a monitoring unit's 1A has no
settings), the unit's own peaks stand, as before.  The mic is always the
unit's: the file still reads it as 0.  The 0C peaks remain the download check.

Store consequence: new live downloads only; no backfill, no migration.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-31 00:17:57 -04:00
serversdownandClaude Opus 5.5 1cce2fcf63 docs: Batch 1 final-review fixes -- reconnect wake, dedup by name, the write encoder's refusal
- Spec: #1, #8, #9 carry their review follow-ups (a72d3a9, 3a1d34a, dbd8a91);
  new open finding 17 (a monitoring MiniMate's 1A has no range, so a download
  then stores Normal-scaled samples; ':S338.17' setup name; no .a5.pkl kept).
- Series-III reference (CRLF kept): the 2026-10-29 row records that the write
  encoder was not moved and now refuses a patch that would not read back.
- CLAUDE.md: the three fixes.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 23:57:13 -04:00
serversdownandClaude Opus 5.5 1626e521ae docs: 1c bench Batch 1 -- #1, #8, #9 fixed; #15 retracted; the 1A layout after unescaping
- Spec (Left open by the 1c bench): #1 b320a53, #8 9492e49, #9 ce441a0, #2 via the
  dev merge 342c696; #15 retracted in place (sent NULL = unknown, by design).
- Series-III reference: a 2026-10-29 row -- the SUB 1A settings fields read after
  unescaping (mode -7, rate -6, interval -4, record time +6), the old
  'anchor-7 constant 0x10' was the escape before 04 at 1024 sps, the channel
  block stays on raw bytes (open: a float containing an escapable byte), and a
  monitoring BE9441 answers 1A with its device-info block.  CRLF kept.
- CLAUDE.md: Batch 1 status.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 23:28:39 -04:00
serversdownandClaude Opus 5.5 0dbd0b506d docs(plan): 1c bench fixes, Batch 1 -- #1 settings decode, #9 read-back reconnect, #8 downloads via the file import path; #15 retracted
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 23:08:56 -04:00
serversdownandClaude Opus 5.5 342c69602d merge: dev into feat/series4-sfm-parity -- v0.32.0, #42, #47/#49, #44/#45, the S3 decode checker
Brings the branch up to dev (41 commits) before the 1c bench fixes, which
touch code dev changed: the histogram reader (#47/#49, bench finding #2), the
v0.32.0 event-time rules, the Blastware file's setup-block fields (#44/#45),
and the decode checker for verifying stored S3 downloads.

One conflict: the top of the Series-III reference's change table -- both sides
added rows; kept all, in date order, CRLF preserved.  CLAUDE.md, README,
blastware_file.py, models.py and database.py merged cleanly.  Suite: the known
16 failures only (15 test_bw_ascii_report, test_save_imported_bw_without_report_
works_unchanged, which also fails on dev); 1237 passed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 22:51:42 -04:00
serversdownandClaude Opus 5.5 335f70ff46 docs: the Micromate line hold stays for now; SFM handling call-ins is the long-term fix
Brian, 2026-10-29: not expected to be a problem in practice.  Settles the 1c
ring-path merge gate; Run B stays open, not blocking.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 21:02:20 -04:00
serversdownandClaude Opus 5.5 7491cd4b6f docs: the 1c bench pass and the ring-path results (2026-10-29)
- Spec: the 1c bench pass on BE9441 and UM20147, each on its own modem, and
  its 16 findings (a new 'Left open by the 1c bench' section).  Ring-path
  results, measured: with THOR's watchdog off a call-home reaches THOR when
  nobody holds the line (Run 0, via ListenerAchTcp) and is lost when SFM holds
  it (Run A: the unit times out and does not retry); with THOR polling, SFM gets
  no reply and THOR is undisturbed (A2, step 1).  Decision owed before merge:
  the Micromate line hold.
- Micromate reference: retracts 'ListenerAchTcp never used' in place (it
  accepted tonight's call-home; port 12345); a call-home that rings on another
  receiver's connection is lost; a second TCP connection while THOR holds the
  line is accepted but silent.
- CLAUDE.md: 1c status, the open decision, THOR's log location.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 20:49:28 -04:00
serversdownandClaude Opus 5.5 3528dde970 docs(micromate): THOR's log location, its watchdog cadence, and the unit that went quiet after a THOR disconnect
C:\THORDATA\Logs\ (Brian).  From the 2026-10-29 log: the watchdog reads each
unit's serial every ~15 s; Unit_CommandOutOfRange follows every ReadUnitStatus
for every unit (fleet-wide noise); after a manual THOR disconnect UM20147
answered neither SFM nor THOR's own reconnect ("Mismatch connection found").

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 20:16:46 -04:00
serversdownandClaude Opus 5.5 e9d352ad99 docs: the decode checker's first full run; correct the #53 note
First full run over DL2's 70,042 report-paired events (22 min, --jobs 4):
every expectation the spec set holds.  Setup and notes match everywhere;
geophone samples are exact on 6,491/6,524 waveforms across 2016-2026,
the other 33 being the 1.250 in/s range read 8x on SFM's Normal
assumption; every histogram is typed as a waveform without its filename
(#41); the three #53 files are the only waveform time mismatches.  New
findings: histogram PVS, mic psi, mic dB on ~1,000 events, ~37
sub-minute histograms, 26 histogram start dates.

The #53 note is corrected in place: those files decode as waveforms with
Blastware's full sample count; only their time falls back to the footer
start.  scratch/verify_bw_fields_against_xml.py is retired -- the
checker replaces it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-10-29 19:55:07 -04:00
serversdownandClaude Opus 5.5 6bdd140c29 docs(plan): the Series 3 decode checker, task by task -- and T438HGTZ is not truncated
Eight tasks: the XML report parser, SFM's side from the bytes alone, the
field-by-field comparison, carve-outs (saturation first), the parallel
runner, the summary and grouped detail report, run-to-run changes with a
one-event view, and the first full run checked against what is known.

While pinning the plan's test values on real files: T438HGTZ.B30W, called
"3 samples short" by the setup-field harness, matches Blastware exactly.
Its Tran, Vert and MicL end 3 samples before Long, and Blastware's own
sample table does the same -- its last three rows carry only the Long cell.
The harness compared Tran's length with the table's row count.  The spec
now says so, and the plan compares samples row by row by running channel.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-10-29 18:30:08 -04:00
serversdownandClaude Opus 5.5 af703808db docs(spec): the Series 3 decode checker -- SFM's file-only decode against Blastware's XML reports
The first of four pieces toward SFM producing everything Blastware reports
from the event file alone: compare every field, sample and histogram
interval with DL2's 70,042 _XML.XML reports (2016-2026), report what
matches, what doesn't and what SFM can't produce yet, grouped for
diagnosis, run after run.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-10-29 17:47:34 -04:00
serversdownandClaude Opus 5.5 2560ef4586 docs: THOR's watchdog interval is a setting; the ring-path test varies it
- micromate reference: the watchdog can check every 5 s, hourly or never
  (Brian, operator-reported).  The 10-14 "reconnects continuously" describes
  that THOR's setting, not fixed behaviour; whether a check holds the line,
  and how a call-home reaches THOR with the watchdog off, are unmeasured.
- spec, ring-path test: the old setup ("a unit THOR is not otherwise
  watching") would not test the production path, since THOR receives a
  call-home on its own connection.  Revised: UM20147 as a THOR test unit; Run 0
  baseline with the watchdog off; Run A with SFM holding the line; Run A2 and
  Run B at the fleet's watchdog setting; after the 1c bench pass.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 13:12:29 -04:00
serversdownandClaude Opus 5.5 073284fc88 docs: phase 1c -- the webapp by serial, and the Series-3 guard on legacy writes
- CLAUDE.md: a 1c entry under Where things stand (serial mode, what follows
  the unit's own answer, writes off until phases 4-5, the Node-run page tests)
  and the legacy-route guard in the REST API notes, with why the stop tools
  are exempt.
- Spec: the 1c build status; the ring-path Runs A/B are still owed before
  serial mode is used on a unit that calls home to THOR; which parked 1c items
  the page settles (CORS: same origin; the S4 mic is not shown).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 12:01:39 -04:00
serversdownandClaude Opus 5.5 c3746a6a01 docs(spec): park event deletion with the future call-in receiver
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:38:05 -04:00
serversdownandClaude Opus 5.5 eecabc76eb docs(plan): phase 1c -- the webapp by serial, and the wrong-series safeguards
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-28 23:20:26 -04:00
serversdownandClaude Opus 5.5 02d8517ebd docs(spec): park the MiniMate speed-ups, measured -- after 1c
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-28 23:16:50 -04:00
serversdownandClaude Opus 5.5 20ea61e0e9 fix(minimateplus): push_config_raw checks every block before the first write goes out (#46 review)
Review of b5037b0 (measured on 12 recorded SFM compliance reads): the read
keeps three escape bytes from its reply headers, so every real config image is
refused by write_image -- correctly, but only after 68 and 73 had been sent,
with a message saying nothing was.  All four blocks are now checked first; the
test feeds the block exactly as SFM's read produces it and asserts no frame is
sent (two went out without the check).

Config push stays unusable on purpose: fixing that read alone would let the
compliance encoder write some fields to the wrong bytes (e.g. 4,096 sps as
4,112) while the image still passes.  The rework -- logical read, encoding at
measured offsets with #48, a diff check, N pinned per SUB, an idle check, the
start/stop safeguards on POST /device/config -- is recorded in the spec and on
#46.  Start/stop frames are unchanged (verified byte-identical by the review).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 03:17:34 -04:00
serversdownandClaude Opus 5.5 329f7f2abb docs: retract the MiniMate write-frame model in place (#46)
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 02:54:56 -04:00
serversdownandClaude Opus 5.5 a7f581f66a docs(spec): the persist_download alignment follows what v0.32.0 shipped -- event-record times, the estimate guard
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 00:20:54 -04:00
serversdownandClaude Opus 5.5 98def4aae0 docs(spec): a stop starts a call-home on a unit with auto-call-home -- unmeasured on Series 3
Brian: stopping by command or keypad with ACH enabled makes the unit call home
and upload events + MLG, which can take minutes.  Fits UM20147's 0x01 after a
stop (10-25).  Owed: measure a MiniMate stop with ACH on, through the bridge.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 00:17:29 -04:00
serversdownandClaude Opus 5.5 7100d8344a docs(reference): point §7.8.9's open items at the Series-III audit, #53
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
2026-10-27 00:17:15 -04:00
serversdownandClaude Opus 5.5 d7e65f5d15 docs: MiniMate start through SFM verified on BE9441 -- the start/stop bench check is complete
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 00:13:37 -04:00
serversdownandClaude Opus 5.5 f91949be89 fix(decode): a Series-3 waveform's time comes from the instrument's embedded event record
Brian's requirements: the instrument's data is the only time source; a filename
is a cross-check, never a fallback (an event SFM receives itself has none).

The record (found by reading a seismo_lab Inspector dump; Series-III reference
§7.8.9): 00 28 05 00 ?? ?? | fe 80 | trigger | stop, times dd mm yyyy(BE) 00 hh
mm ss.  Measured on 7,935 waveforms (DL2 + prod store): exactly one candidate
validates in every file; trigger = Blastware's report 1,320/1,320, = filename
7,935/7,935, = the unit's 0C record 10/10.

Provenance (requirement 6, measured): in Blastware's download of 8 BE9441
events the record -- with 24 B before and 22 after -- occurs exactly once in the
unit's own A5 reply payloads; SFM-only downloads (no Blastware) carry it too.
It is instrument data, not Blastware's.

- _embedded_event_record(): every fe 80 before the footer is a candidate; it
  counts only with the lead bytes, two well-formed times (zero byte zero),
  footer ts1 <= trigger <= stop, stop = footer ts2 or a second before, and a
  length matching the record time.  Exactly one must count; none or several is
  a decode problem, never a guess.
- Without one: the footer estimate, timestamp_source 'estimate', a
  decode_problems entry, a WARNING.  No filename fallback.
- A filename that disagrees is logged; the decoded time is kept.  A paired
  report fills in only without a validated record (apply_report_to_event, the
  sidecar dict overlay, event_to_sidecar_dict) and is logged when it disagrees.
- decode_blastware_bytes(raw, name=None): no file or name needed;
  save_imported_bw uses it (no temp file).  Event gains timestamp_source and
  decode_problems; the sidecar records both.
- Histograms unchanged (#51): their record (fe f5) is noted, not used.

Tests: raw bytes with no name (ZI0, 7 BE12844 oracles), a disagreeing name, each
validation rule alone, two valid candidates, no filename fallback, report
precedence, sidecar.  7 mutants, each caught.  Real data, decoded with no name:
7,961/7,961 waveforms on the record, 0 disagreements with filename or report;
10,433/10,433 prod histograms unchanged.  Suite: only the 16 known failures.

Open (reported, not changed): 3 DL2 files named as waveforms whose body the
waveform codec does not recognise keep the footer start, 4 s off, as on dev.
None in prod.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01MUHR251NLznsFvPSrfegqL
2026-10-26 23:59:22 -04:00
serversdownandClaude Opus 5.5 6f2acc79e6 docs(spec): owe persist_download an alignment with dev's waveform-time restamp before the merge
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 19:16:25 -04:00
serversdownandClaude Opus 5.5 1da3083665 docs: the MiniMate histogram and stop checks are done; start is still owed
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 19:10:04 -04:00