273 Commits
Author SHA1 Message Date
serversdownandClaude Opus 5.5 335f70ff46 docs: the Micromate line hold stays for now; SFM handling call-ins is the long-term fix
Brian, 2026-10-29: not expected to be a problem in practice.  Settles the 1c
ring-path merge gate; Run B stays open, not blocking.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 21:02:20 -04:00
serversdownandClaude Opus 5.5 7491cd4b6f docs: the 1c bench pass and the ring-path results (2026-10-29)
- Spec: the 1c bench pass on BE9441 and UM20147, each on its own modem, and
  its 16 findings (a new 'Left open by the 1c bench' section).  Ring-path
  results, measured: with THOR's watchdog off a call-home reaches THOR when
  nobody holds the line (Run 0, via ListenerAchTcp) and is lost when SFM holds
  it (Run A: the unit times out and does not retry); with THOR polling, SFM gets
  no reply and THOR is undisturbed (A2, step 1).  Decision owed before merge:
  the Micromate line hold.
- Micromate reference: retracts 'ListenerAchTcp never used' in place (it
  accepted tonight's call-home; port 12345); a call-home that rings on another
  receiver's connection is lost; a second TCP connection while THOR holds the
  line is accepted but silent.
- CLAUDE.md: 1c status, the open decision, THOR's log location.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 20:49:28 -04:00
serversdownandClaude Opus 5.5 3528dde970 docs(micromate): THOR's log location, its watchdog cadence, and the unit that went quiet after a THOR disconnect
C:\THORDATA\Logs\ (Brian).  From the 2026-10-29 log: the watchdog reads each
unit's serial every ~15 s; Unit_CommandOutOfRange follows every ReadUnitStatus
for every unit (fleet-wide noise); after a manual THOR disconnect UM20147
answered neither SFM nor THOR's own reconnect ("Mismatch connection found").

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 20:16:46 -04:00
serversdownandClaude Opus 5.5 4117b056aa scratch: ring-path poller for the Runs A/B bench test
Asks the bench SFM for a Micromate's status on a fixed interval (Run B) or
once (Run A), with run_state=true, and logs each answer with its time as JSON
lines: HTTP status, seconds, the raw 0x49 code, and the detail of any refusal
(503 call-home-in-progress / could-not-connect).  Read-only on the unit;
refuses :8200.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 13:17:43 -04:00
serversdownandClaude Opus 5.5 ee02874cb0 feat(sfm): opt-in raw SUB 0x49 code on a Series-4 status read
GET /device/monitor/status?serial=UM...&run_state=true adds
detail.run_state = {code, name}.  For the ring-path bench test: the code
during and after a call-home (0x01 for ~18 s after a stop, inferred to be
call-home attempts; 0x03 = calling home) is what the test watches.  Opt-in
because it is one more round trip (~0.65 s on cellular); a plain status read
is unchanged.  Series 3 has no 0x49 and ignores it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 13:15:44 -04:00
serversdownandClaude Opus 5.5 2560ef4586 docs: THOR's watchdog interval is a setting; the ring-path test varies it
- micromate reference: the watchdog can check every 5 s, hourly or never
  (Brian, operator-reported).  The 10-14 "reconnects continuously" describes
  that THOR's setting, not fixed behaviour; whether a check holds the line,
  and how a call-home reaches THOR with the watchdog off, are unmeasured.
- spec, ring-path test: the old setup ("a unit THOR is not otherwise
  watching") would not test the production path, since THOR receives a
  call-home on its own connection.  Revised: UM20147 as a THOR test unit; Run 0
  baseline with the watchdog off; Run A with SFM holding the line; Run A2 and
  Run B at the fleet's watchdog setting; after the 1c bench pass.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 13:12:29 -04:00
serversdownandClaude Opus 5.5 9082236c5e fix(webapp): the final review's three page findings
- The arrow keys reached the legacy per-index waveform route in serial mode,
  even with no list loaded (an unlocked MiniMate chain walk + 5A on the same
  modem session).  perIndexLive() is now the one rule for the per-index
  buttons, the chips and the keyboard: live only for a list loaded without a
  serial that has events.
- A failed reconnect left the previous unit's confirmation live (badge,
  Diagnostics incl. the unguarded blind/slow-drip stops, call-home read).
  connectUnit() now drops it before it identifies; only this answer confirms.
- Unit strings reached innerHTML: the Device tab's cards (active_setup, new in
  1c) and its compliance/project tables now render as text, and Diagnostics'
  error spans go through escapeHtml().
- CLAUDE.md: the ring-path Runs A/B are a merge gate (the spec's prerequisite
  to a webapp sending serial), not only a use-time one.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 12:16:49 -04:00
serversdownandClaude Opus 5.5 073284fc88 docs: phase 1c -- the webapp by serial, and the Series-3 guard on legacy writes
- CLAUDE.md: a 1c entry under Where things stand (serial mode, what follows
  the unit's own answer, writes off until phases 4-5, the Node-run page tests)
  and the legacy-route guard in the REST API notes, with why the stop tools
  are exempt.
- Spec: the 1c build status; the ring-path Runs A/B are still owed before
  serial mode is used on a unit that calls home to THOR; which parked 1c items
  the page settles (CORS: same origin; the S4 mic is not shown).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 12:01:39 -04:00
serversdownandClaude Opus 5.5 c4cb979dfb feat(webapp): the status panel shows the unit's clock and event count
Task 3's brief asked for them and they were missed: with a serial, the panel
now shows UnitStatus.device_time and event_count, "—" where null (Series 3
reports both as null).  Without a serial the two fields stay hidden.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 12:00:12 -04:00
serversdownandClaude Opus 5.5 a709d2388d feat(webapp): config and call-home writes wait for phases 4-5; Diagnostics only for a confirmed Series-3 unit
- Config, with a serial: Read shows the unit's shared UnitSettings (setup,
  record mode, sample rate, record time, histogram interval, geo trigger,
  notes; — for null) in place of the write form.  settingsRows() is in the
  device-routing block, Node-tested; the rows are rendered as text, since
  setup names and notes come from the unit.
- Write stays off for both series (and without a serial), tooltip
  "Coming in phase 5 (#46)"; Call Home write likewise, "Coming in phase 4".
- Call Home read follows controlsFor().callHomeRead; for a confirmed Series 4
  the tab says "Not yet available for Series 4".
- Diagnostics: every button follows controlsFor().diagnostics (Task 3), and a
  refresh for anything but a confirmed Series-3 unit sends nothing and says
  why.  Its requests carry the typed serial, so the server guard checks it.
- Without a serial the legacy reads are unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:59:11 -04:00
serversdownandClaude Opus 5.5 3f249e2322 feat(webapp): start/stop through the audited serial path, with the honest result
- With a serial, Start / Stop ask first ("Start monitoring on BE9441?"), then
  POST once to the audited change -- never retried; both buttons stay off while
  it is in flight, so a double click cannot send twice.
- The status bar shows changeSummary() of the ChangeResult, on a 409/502 too
  (dry run, already-in-state, confirmed a -> b, or the outcome and read-back);
  an error without one shows its detail verbatim; no reply from SFM says the
  command may have been sent and where to look, rather than that nothing was.
- Then one status read updates the panel.  The legacy 5 s confirm poll is not
  used in serial mode; with a blank serial start/stop are unchanged.
- Diagnostics' Stop, which goes the same way in serial mode, shows the same
  summary; deviceFetch errors carry it for any non-200 ChangeResult.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:56:36 -04:00
serversdownandClaude Opus 5.5 9aae3b09de feat(webapp): list and download events by serial, for both series
- Load events with a serial lists the shared EventRef shape as a table: index,
  time, type, PVS and the three peaks (or —), each row with its own Download.
- Download POSTs the row's event_id; SFM checks and stores it.  The status bar
  says what was stored (or that it already was), and the stored event opens
  in the viewer.  A refusal shows the server's detail verbatim.
- eventView() (device-routing block, Node-tested) reads both event shapes for
  the table, the chips and the peaks bar.
- A list loaded without a serial keeps the chips and the per-index Load /
  Save / Download buttons, unchanged; for a serial-loaded list those buttons
  are off with a tooltip pointing at the rows.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:54:43 -04:00
serversdownandClaude Opus 5.5 44d6e754bd feat(webapp): name a unit by serial; series badge from the unit's own answer; Hang up for Series 4
- A Serial field beside host/port.  With one, the Live tabs use the serial-based
  endpoints (both series); without, every read behaves as before.
- The series badge, Hang up (Series 4), Diagnostics (Series 3), call-home read and
  the disabled config/call-home writes all follow applyControls() <- controlsFor()
  on the unit's own /device/info answer; editing the serial, host or port drops
  the confirmation.  Erase additionally needs a confirmed Series 3.
- Every /device/ request goes through deviceRequest/deviceFetch <- deviceUrl
  (a static test enforces it); the legacy per-event routes joined deviceUrl
  (event_waveform / event_file, index in the path).
- The status panel and Device tab read both shapes (shared and legacy).
- In serial mode the connect skips the legacy storage_range read (one connection
  fewer; a Micromate has no such route).  Start/stop without a serial behave as
  before; with one, only for a confirmed series.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:50:24 -04:00
serversdownandClaude Opus 5.5 e3717706f8 feat(webapp): the device-routing rules as pure functions, tested through Node
One block of sfm_webapp.html (/* <device-routing> */) holds every rule that
decides where a /device/ request goes or whether a series-specific control is
live: seriesFromSerial, unitQuery, deviceUrl, confirmedSeries, controlsFor,
changeSummary, downloadSummary.  No DOM, no fetch, so the tests run it in Node.

The safety rules it pins: a control follows the unit's own /device/info answer,
never a typed serial alone, and stops counting when the serial is edited;
Diagnostics only for a confirmed Series 3, Hang up only for Series 4; config and
call-home writes off for both series until phases 4-5.  Also a test that the
page's inline scripts parse together (shared global scope).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:46:08 -04:00
serversdownandClaude Opus 5.5 1cb11abcef fix(sfm): legacy Series-3 writes and erase refuse a unit that does not answer as Series 3
0xA2 is CONFIRM ERASE on a MiniMate and ends a call-home on a Micromate, and the
legacy host/port routes had no identity check: only the MiniMate parser's
inability to read a Micromate's replies stood between Diagnostics' Erase and a
Micromate (phase 1c safeguard, agreed with Brian 2026-10-28).

_require_series3(unit_serial, expected) refuses (409, 'nothing sent') unless the
unit's own serial is Series 3 and, when ?serial= names one, that one:
- POST /device/config (+ /config/project) and /device/events/erase: the serial
  connect() already reads -- no extra request;
- /device/rescue (when it writes call-home or erases) and POST /device/call_home:
  one SUB 0x15 read (new MiniMateClient.read_serial).
Exempt, with the reason in a comment: legacy monitor start/stop, blind stop, slow
drip, spam -- 0x96/0x97 mean the same on both series (measured), and the rescue
tools must reach a unit too wedged to answer.

Tests: each guarded route refuses a unit answering UM20147 and a different BE
unit with no write call, proceeds for the named unit (normalised), reuses
connect()'s serial where it has one; the blind stop builds no client;
read_serial decodes BE9441's recorded 0x15 reply.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:43:42 -04:00
serversdownandClaude Opus 5.5 c3746a6a01 docs(spec): park event deletion with the future call-in receiver
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-29 11:38:05 -04:00
serversdownandClaude Opus 5.5 eecabc76eb docs(plan): phase 1c -- the webapp by serial, and the wrong-series safeguards
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-28 23:20:26 -04:00
serversdownandClaude Opus 5.5 02d8517ebd docs(spec): park the MiniMate speed-ups, measured -- after 1c
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-28 23:16:50 -04:00
serversdownandClaude Opus 5.5 20ea61e0e9 fix(minimateplus): push_config_raw checks every block before the first write goes out (#46 review)
Review of b5037b0 (measured on 12 recorded SFM compliance reads): the read
keeps three escape bytes from its reply headers, so every real config image is
refused by write_image -- correctly, but only after 68 and 73 had been sent,
with a message saying nothing was.  All four blocks are now checked first; the
test feeds the block exactly as SFM's read produces it and asserts no frame is
sent (two went out without the check).

Config push stays unusable on purpose: fixing that read alone would let the
compliance encoder write some fields to the wrong bytes (e.g. 4,096 sps as
4,112) while the image still passes.  The rework -- logical read, encoding at
measured offsets with #48, a diff check, N pinned per SUB, an idle check, the
start/stop safeguards on POST /device/config -- is recorded in the spec and on
#46.  Start/stop frames are unchanged (verified byte-identical by the review).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 03:17:34 -04:00
serversdownandClaude Opus 5.5 329f7f2abb docs: retract the MiniMate write-frame model in place (#46)
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 02:54:56 -04:00
serversdownandClaude Opus 5.5 b5037b0b1e fix(minimateplus): MiniMate config writes are ordinary escaped requests carrying whole blocks; apply_config reads the unit's own trigger block (#46)
Measured against every Blastware request on record: the uploaded Feb-Apr 2026
captures (3,869 frames, 3,869 re-encode exactly) and BE9441's two sends on
2026-10-26 (26 write frames).  A write is the standard 16-byte request plus its
data, every 02/03/04/10 escaped, SUM8 checksum; the length field is the data's
length.  A config block starts with its own length N and is written as N + 2
bytes: event index (68) and trigger (82) as read plus 02 00 / 00 00 (constant on
15 sends), waveform data (69) and the 2,092-byte compliance image (71) whole.
The compliance image goes in addressed chunks (params[2:4] = address): 512 bytes
tonight (Blastware 10.74), 1,024 in March.

- framing.build_bw_write_frame: uniform escaping, SUM8, length = len(data).
  RETRACTED: 'only BW_CMD doubled', the 'DLE-aware checksum', 'offset = data[1]
  + 2' -- fitted to frames still holding their escape bytes ('data 91, offset 90'
  was 90 bytes and one escape).  It got 7 of every 13 frames in a write wrong.
- protocol.write_image(): unescapes (callers may pass the parser's form), adds
  the trailing two bytes to an N-byte block, and REFUSES anything else before a
  byte is sent -- an edit beside a kept escape byte (the old encoder's anc-9
  hazard) leaves an image one byte long.
- write_compliance_config_raw: 512-byte addressed chunks, then confirm 72.
- read_event_index / read_waveform_data_raw unescape before slicing (a block
  holding 02/03/04/10 came out short); new read_trigger_config (SUB 0x2E).
- apply_config reads the unit's trigger block.  RETRACTED: the block
  'hardcoded from 3-11-26 -- no read exists'.  Blastware reads it; byte 5 has
  been 01 / 03 / 04 by unit and session, and the March copy (03) would have
  changed BE9441's (01).
- The call-home write (7E) goes through write_image: its 127-byte 'read + 00 00'
  is the 126-byte image (N = 0x7C).  No Blastware 7E is on record here -- that
  one is inferred from the other 77 write frames.

Tests: tonight's 26 and every Feb-Apr write frame rebuilt byte for byte; each
block as read written exactly as Blastware wrote it; the parser's form; the
stray-byte refusal; the reads against the unit's recorded replies; apply_config
writes BE9441's own trigger block.  Six mutants, each caught.  The old
test_write_frames.py (25 tests that had been skipping) runs now that the
captures are here, rewritten to the measured model.

Not yet sent to a unit: a config push changes settings, so its first live use
is a bench session with Brian.  No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 02:54:26 -04:00
serversdownandClaude Opus 5.5 a7f581f66a docs(spec): the persist_download alignment follows what v0.32.0 shipped -- event-record times, the estimate guard
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 00:20:54 -04:00
serversdownandClaude Opus 5.5 98def4aae0 docs(spec): a stop starts a call-home on a unit with auto-call-home -- unmeasured on Series 3
Brian: stopping by command or keypad with ACH enabled makes the unit call home
and upload events + MLG, which can take minutes.  Fits UM20147's 0x01 after a
stop (10-25).  Owed: measure a MiniMate stop with ACH on, through the bridge.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 00:17:29 -04:00
serversdownandClaude Opus 5.5 d7e65f5d15 docs: MiniMate start through SFM verified on BE9441 -- the start/stop bench check is complete
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 00:13:37 -04:00
serversdownandClaude Opus 5.5 ca5c401c6f fix(device_access): a start's read-back waits out the sensor check, then wakes the MiniMate with retries
Second start through SFM, BE9441 2026-10-26 23:54:41: acked 0x69, and Brian saw
'starting, performing sensor check, recording' -- but the read-back's single
SESSION_RESET + POLL went out 2.3 s after the ack, inside the ~30 s sensor
check, and was never answered or re-sent (504 after 120 s, audit ca7b5b42).
Brian: every unit is set to sensor-check before monitoring, ~30 s, then
'Recording...'.

- MiniMateProtocol.wake(attempt_s, deadline_s): SESSION_RESET + POLL re-sent
  every attempt_s until the unit answers, then the POLL data step; a named
  timeout at the deadline.  Reads only.  MiniMateClient.wake() wraps it.
- The Series-3 change: after a START, the first read waits S3_SENSOR_CHECK_S
  (30 s) before asking; every read then wakes with retries (every 5 s, up to
  60 s).  A stop is unchanged -- its read-back was confirmed three times tonight.

Tests: a unit deaf for 4 probes is asked a 5th time and answers; a unit that
never answers ends in the named timeout after ~6 probes; a start's first read
waits the sensor check, a stop's does not; every read is preceded by a wake.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-27 00:02:10 -04:00
serversdownandClaude Opus 5.5 9886422212 fix(device_access): wake a MiniMate before every state read in a start/stop, so a start's read-back is answered
BE9441, 2026-10-26 23:41:48 (through the bridge): SFM's start (0x96, Blastware's
own bytes) was acked 0x69 and the unit began monitoring -- Brian saw it -- but
the read-back sent one bare 0x1C two seconds later and got nothing for 120 s,
so the change reported 'sent and acknowledged, but reading the state back
failed' (504, audit 0c1cf813).  Nothing was retried.

A monitoring MiniMate ignores a bare request until SESSION_RESET + POLL
(measured 2026-04-08).  The read-back had relied on the connect's wake; a stop's
read-back (18:53, the unit idle by then) never needed it.  Every state read in
the change now goes through _woken_state: client.poll() (41 03, POLL, 41 03,
POLL -- the connect's own sequence), then 0x1C.

Test: after the send, every 0x1C read is preceded by a POLL.  No codec, store or
DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 23:51:15 -04:00
serversdownandClaude Opus 5.5 6f2acc79e6 docs(spec): owe persist_download an alignment with dev's waveform-time restamp before the merge
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 19:16:25 -04:00
serversdownandClaude Opus 5.5 1da3083665 docs: the MiniMate histogram and stop checks are done; start is still owed
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 19:10:04 -04:00
serversdownandClaude Opus 5.5 258a6e2143 test(minimateplus): a 71 KB histogram past the old 128-chunk cap walks as Blastware's and rebuilds its file
Tonight's bridge recording of BE9441 (16:08-19:06) as a fixture, with
Blastware's files: Blastware's and SFM's requests in order (1,596, 722 of them
5A, 722 A5 replies), two Blastware config writes, SFM's stop, and three events.
Event 2 is a 4,096-sps, 2 s histogram of 71,088 bytes -- 139 requests, two 64 KB
crossings.

Measured live the same evening (SFM through the bridge, read-only downloads):
SFM's files for events 1 and 2 are byte-identical to Blastware's (sha256), the
71 KB histogram included -- the first event past the old cap downloaded from a
unit.  Event 0, the mic-off histogram, was refused ('decodes as neither'), as
expected on this branch: its decoder fix (#47) is on dev.

The test, fed the recorded replies with max_chunks=128: SFM's walks send
exactly Blastware's 139 and 118 requests and rebuild both files byte for byte.
Reverting the STRT-sized cap (8acb951) fails it.  No code change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 19:09:48 -04:00
serversdownandClaude Opus 5.5 d990466407 fix(minimateplus): the 0x1C status reads a histogram run as monitoring, and unescapes before counting from the end
Measured on BE9441 tonight, through the recording bridge:

- Monitoring flag 0x0B while recording a histogram (confirmed at the unit), 0x00
  idle.  Only 0x10 had been measured as monitoring (BE11529, 2026-04-08), so the
  status showed 'not monitoring' and the change path refused the state as
  unknown(0x0B) -- refused, not skipped, which is the design working.  0x0B joins
  S3_RUN_STATES and S3_MONITORING_FLAGS as measured.  The shared status's
  'monitoring' now follows the change path's reading: None for an unmeasured
  flag, never a guessed False.
- Free memory 0x000D0E04 arrived as 0d 0e 10 04.  The parser keeps the 10 of a
  10 02/03/04 escape, so every field counted from the end read one byte off:
  419.84 V and 251,655,168 bytes for 6.76 V and 983,028.  New
  framing.unescape_reply() (also used by parse_strt_end_key) runs first.

Tests: the two recorded replies (idle 16:24, monitoring 18:47) decode to the
unit's own values; each escaped value in the last ten bytes decodes; the status
mapping for 00 / 10 / 0B / unmeasured.  No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 18:53:11 -04:00
serversdownandClaude Opus 5.5 8acb9512a9 fix(minimateplus): size the 5A chunk cap from STRT, refuse a misread STRT, TERM only a tail
Follow-ups from the review of 887e75d (verdict: keep, with fixes; no critical).

- The cap: a caller's max_chunks (client.py passes 128) now bounds only a walk
  whose end is unknown.  With STRT it cut every event past ~66 KB short --
  2,545 of 63,500 archived histograms are bigger (the review's count, DL2).
  Strict raised; legacy sent a TERM for most of the event, or a bare ValueError.
- A STRT claiming less than one 0x200 chunk, or more than 4 MiB (a sanity bound,
  not a measured limit), is refused as a misread, in both modes -- once a bare
  ValueError and a 500.
- TERM is sent only for a true tail (< 0x200).  After an early end the legacy
  walk returns what arrived and sends none.
- build_5a_request wraps build_bw_frame; the old 5A helpers are marked
  superseded (kept for tests/test_5a_protocol.py) and their imports dropped.

Tests: all 8 recorded events (were 4) walk exactly as Blastware and rebuild its
own files; an end key holding escaped bytes; a 300 KB event past a 128 cap; both
misread-STRT refusals; the 1A frames BE9441 answered post-fix; the checksum
vectors retargeted.  Mutants the review saw survive (no STRT un-escape; a
standard-request escape revert) and 3 new ones are each caught.

Measured on the way: a reply's checksum is SUM8 of its unescaped payload,
748/748.  The 'S3 checksums frequently fail' note was the parser summing its
own kept escape bytes; noted, parser unchanged.

Docs: the crossing count corrected to four (events 1, 3, 5, 7); the remaining
stale 5A sections in CLAUDE.md annotated; the write-frame suspicion recorded as
inferred only.  No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 15:16:10 -04:00
serversdownandClaude Opus 5.5 f61fc3cc78 test(minimateplus): the walk rebuilds Blastware's own files for the page-crossing events
Brian's Blastware files from the recorded session (events 0, 1, 3, 7 -- three
cross a 64 KB page) as fixtures; SFM's walk, fed Blastware's recorded replies,
writes each one byte for byte.  Live the same day, SFM's own downloads of all 8
events were byte-identical to Blastware's (sha256), the 4 crossings included --
and events 2-5's shorter sample counts (20,490-21,011 vs 21,504) are in
Blastware's files too: the unit's own recording.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 14:45:38 -04:00
serversdownandClaude Opus 5.5 6f31eca366 docs: the 64 KB page bug is fixed; the 5A 'non-standard frame' model retracted in place
CLAUDE.md: the KNOWN BUG entry marked fixed (887e75d) with what settled it, and
retraction notes under the 5A sections that described the misreading (partial
stuffing, offset_hi 0x10 raw, 11-byte params, metadata pages 0x1002/0x1004).
Series-III reference: a 2026-10-26 (3) row.  Spec: the MiniMate check updated.
Code comments that called the page bug open, updated; the adapter's struct.error
mapping kept as a defence, its message and test no longer naming the old bug.

Verified live on BE9441 the same day: all 8 events downloaded by serial, the 4
that cross a 64 KB page included, each whole and matching the unit's own peaks.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 14:44:11 -04:00
serversdownandClaude Opus 5.5 887e75d1ba fix(minimateplus): MiniMate requests escape 02/03/04/10, and the 5A walk is 32-bit linear -- the 64 KB page bug
A recording of Blastware downloading all 8 of BE9441's events (three crossing
a 64 KB page; tests/fixtures/minimate-bench-10-26-26-blastware/) settles it:
every one of its 748 requests is the standard 16-byte payload with a SUM8
checksum and every 02 / 03 / 04 / 10 byte DLE-escaped -- 748/748 re-encode
byte-identically.  A 5A request is not a special frame: it is that payload with
a 2-byte LENGTH (0x0200 per chunk, the remainder for TERM) and a 4-byte linear
ADDRESS.  The walk is the event's start, +0x200 at a time carrying into the page
byte, then TERM at the next boundary for exactly the remainder.

What the old model misread: the fixed 'offset 0x1002' is length 0x0200 escaped
(10 02 00); the first event's 'metadata pages at 0x1002/0x1004' are its chunks
at 0x0200 and 0x0400; the 16-bit counter could not leave the key's page.

- build_bw_frame escapes the four values (was 0x10 only); new s3_stuff().
- build_5a_request(address, length); parse_strt_end_key() -> the full 32 bits.
- read_bulk_waveform_stream: one linear walk, no event-1 special case; strict
  mode keeps every refusal; an end at or before the start is refused as a
  corrupt STRT (a page crossing is no longer refused -- it downloads).

Tests: all 540 Blastware 5A requests and all 208 others rebuilt byte for byte;
SFM's walks for events 0, 1, 3 and 7 send exactly Blastware's requests and,
fed Blastware's recorded replies, build whole events.  In-page requests are
byte-identical to before.  No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 14:38:19 -04:00
serversdownandClaude Opus 5.5 465bc704dd test+docs: SFM's MiniMate downloads are byte-identical to Blastware's; the 64 KB bug narrowed
Brian's Blastware downloads of BE9441's 20 events give ground truth.  SFM's
re-run downloads of events 0, 1, 3, 4 and 10 are byte-identical to Blastware's
own files; imported first through the watcher route, the same events download
as already_stored (no duplicate rows -- the unit's 0C and Blastware's file agree
on serial + timestamp).  Fixtures: Blastware's P00/Q10 (now asserted equal to
SFM's builds) and QZ0/T80, the two page-crossing events, as byte-exact targets.

The 64 KB page bug, narrowed by a read-only test walk: carrying the page byte
addresses the first chunk in page 0x12 (answered), but the next request carries
a raw 0x03 inside its params (counter 0x032c) and gets no reply.  Pages after
0x11 have such counters; 0x11 does not (event 1 skips 0x0000-0x05FF).  Needs a
Blastware wire capture of event 2 or 19 (recorded in CLAUDE.md, the Series-III
reference and the spec).  No code change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 12:15:50 -04:00
serversdownandClaude Opus 5.5 1ded70fcd9 docs: the MiniMate re-run -- every in-page event verifies; the 'reboot' was our bare 0x02 checksum
Series-III reference: a 2026-10-26 row (5A checksum escape, measured), and the
2026-10-25 row's guessed cause of the mid-download reboot (battery, firmware)
retracted in place -- it was our request.  CRLF kept.  Spec: the re-run, item
by item, and what is still owed.  CLAUDE.md: the phase-1b bullet brought up to
date.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 01:19:46 -04:00
serversdownandClaude Opus 5.5 bf9e32cfc0 fix(minimateplus): a one-event download names an event that crosses the 64 KB page boundary
Bench re-run 2026-10-26: BE9441 events 2 (0111c92c) and 19 (0118a4ca) end in
the next page, so STRT's 16-bit end offset reads lower than the start.  The walk
then failed in bulk_waveform_term_v2 with a ValueError ('end_offset 0x2F06 must
be > last_chunk_counter 0xC92C') that the adapter's struct.error mapping did not
catch: a generic 500.  Strict mode now refuses such an event by name right
after the probe -- 'crosses the unit's 64 KB page boundary ... the known 5A
page bug; not saved' -- before any chunk is sent.  Not stored either way.  The
page bug itself is unchanged (CLAUDE.md: needs a BW capture of a spanning event).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 01:16:12 -04:00
serversdownandClaude Opus 5.5 d56dde768d fix(minimateplus): a 5A request's checksum is DLE-escaped when it is a framing byte
BE9441 never answered 5A chunk 0x7D06 of event 01122f06 -- twice (bench
2026-10-25 and 2026-10-26), each time rebooting ~11 s later.  The request ended
'... 02 03': build_5a_frame wrote the checksum bare, and 0x02 is STX.  Sent with
the checksum escaped ('10 02 03') the unit answered in 28 ms; so did chunk
0x7F06 (checksum 0x04) and 0x8B06 (0x10, which bare reads as DLE+ETX), and the
event downloaded whole and verified (21,504 x 3, peaks equal to the unit's).
Escape set {02, 03, 04, 10}: a Micromate's, measured on 251/251 THOR requests;
the MiniMate's own de-stuffing keeps 10 02/03/04 literal.  About 1 chunk
request in 64 has such a checksum, so roughly half of all multi-chunk downloads
hit one.

Not changed (no evidence either way): build_bw_frame escapes only 0x10 in its
checksum; a keyed read whose checksum is 02/03/04 is untested.  The BW 5A
byte-perfect tests skip on this box (captures absent) -- worth running where
they exist.  No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-26 01:14:42 -04:00
serversdownandClaude Opus 5.5 f34f5c3376 test(minimateplus): pin the BE9441 bodies and files byte for byte, and the TERM's header skip
Re-review of 64273c0: nothing pinned the TERM skip -- a TERM cut one byte off
loses a byte after the END record, invisible to every decode and peak check.
Golden sha256 of both fixtures' bodies and written files (event 0's file is
byte-identical to the one SFM stored at the bench before any fix; event 1's is
the bench's 25,810 bytes plus the 2 recovered), and a TERM moved to 0x1002.
The clipped-blast test now sits two steps past full scale (32032 counts), so it
needs the carve-out.  Spec: the TOOL_VERSION reason corrected (no stored file
is affected); a MicL-only waveform is now refused -- failing safe, bench-check.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 19:01:36 -04:00
serversdownandClaude Opus 5.5 64273c07d3 docs(spec): the MiniMate fixes' review -- the changelog's operational note, a behaviour change, a bench-first item
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:52:42 -04:00
serversdownandClaude Opus 5.5 78617d47ce test(minimateplus): each strict-stream refusal has its own test; a re-poll always follows a SESSION_RESET
Review of 75d79ec / d73a27d (mutation): removing the chunk-timeout raise went
unnoticed because the TERM raise also said 'ended early', and the no-STRT,
metadata-page, mid-stream-terminator and chunk-cap raises had no test at all;
a re-poll without SESSION_RESET passed because the test double ignored it.
Each refusal is now pinned by its own message, each verified by removing it
(bytecode caching off -- same-second, same-size rewrites reuse a stale .pyc).
The strict tests use the shared replay helpers, which load either fixture.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:52:23 -04:00
serversdownandClaude Opus 5.5 a7214c50de test: the Series-3 fake downloads a real event -- c32a9e7 was pushed with 4 tests failing
c32a9e7 made the download check read the 5A body; the Series-3 fake handed
back placeholder frames (['frame']), so 4 plumbing tests in
test_device_access_s3_events.py and test_device_access_event_dispatch.py
failed with "'str' object has no attribute 'data'" -- and that commit was
pushed without the failure set being read.  The fake's one-event download now
carries what a real one does: BE9441 event 1's recorded frames, their decoded
waveform and the unit's own peaks for it.  Those tests now see verified=True
on a whole event.  Suite back to the 16 known fixture failures.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:49:44 -04:00
serversdownandClaude Opus 5.5 c32a9e7851 fix(sfm): a MiniMate download that decodes as nothing is refused, not stored as a histogram
Review of 36f4e5d (measured): with the metadata-page bug put back, 4 of 7
BE12599 non-first waveforms decoded to nothing, and the check stored them
unverified as 'a histogram' -- the worst form of the bug it was built for.
Now: no waveform decode must decode as a histogram (stored unverified) or it is
refused; a waveform's record chain must end on its END record (0x06), as the
file reader requires -- cut-short streams have none; the structure checks run
for every unit and only the peak comparison is limited to a unit confirmed in
normal range (geo_range == 0; an unread range is no longer assumed normal);
a clipped blast at full scale on both sides counts as a match.  Tests pin the
one-step tolerance, both ranges, the END record and the neither case.

No DB or schema change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:47:39 -04:00
serversdownandClaude Opus 5.5 ac34f80daa fix(minimateplus): every A5 header is 12 bytes once inner DLE pairs count as one -- the general rule
Review of 352f694: the metadata-page detection fixed every observed stream but
was one case of a general rule.  An A5 header is 12 bytes in the stripped sense
(TERM's 11); its raw length is 13 whenever the echoed address carries an inner
DLE pair -- the metadata pages at 0x1002 / 0x1004, but equally a sample chunk
or TERM boundary that lands there (inferred: ~1 in 128 events spanning
0x1000-0x1200, not in any capture).  _raw_skip() counts it per frame, the way
probe_skip already did; _has_metadata_pages is gone.  The reviewer measured
the rule reproducing the shipped bodies byte for byte on all 26 current-walk
streams on this box.  Test: a chunk moved to 0x1002 yields the same body.

No DB or schema change; TOOL_VERSION not bumped (the file builder changed, the
.h5 decode did not).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:45:44 -04:00
serversdownandClaude Opus 5.5 f6166b4b04 fix(minimateplus): the boot-aware first POLL resets the parser; a drained or long-trailed banner is seen
Review of d73a27d: _await_poll_or_boot no longer reset the parser and pending
frames the way _recv_one(reset_parser=True) did, so a reused protocol object
with half a frame left over failed startup (UnexpectedResponse A4 vs A5).
Restored.  Also: the banner check now runs before the tail is trimmed (a read
carrying >48 bytes after the banner lost it), and a banner caught during the
200 ms drain is reported, so startup goes straight to the re-poll loop instead
of the full timeout.  Tests for all three.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:43:49 -04:00
serversdownandClaude Opus 5.5 151782365b docs: restore the Series-III reference's CRLF line endings; the pre-trigger is 0.25 s
3898d03 rewrote docs/instantel_protocol_reference.md with LF endings (a 7,327-line
diff for 3 added lines).  CRLF restored; the file's real change is the 3 lines.
Also: BE9441's 21,504 samples are 5 s record + 0.25 s pre-trigger at 4096 sps,
not '+ 1 s' (reference row, fixture README, test comment).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:41:53 -04:00
serversdownandClaude Opus 5.5 3898d03236 docs: the first MiniMate bench run -- four bugs found, what remains of the check
Series-III reference: the 0x15 serial is a C string (BE9441's "BE9441\x00?"),
A5 replies echo their address at data[2:6] (metadata pages only on the
event-1 walk), the unit boots on serial-port open (banner ~3 s, answered 8.8 s
after a reboot's banner), one mid-download reboot, and 24 index entries vs 20
listed events (inferred: monitor-log entries).  Spec: the MiniMate check's
first run, item by item, and what is still owed.  CLAUDE.md: the phase-1b
"unproven" line retracted in place, with the four bugs and the re-run owed.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:19:14 -04:00
serversdownandClaude Opus 5.5 d73a27d2e3 fix(minimateplus): a MiniMate that boots on connect is waited for, not given up on
BE9441 on a serial cable (bench, 2026-10-25) twice sent "Operating System"
~3 s after the port opened and ignored the POLL sent before it; the request
then failed at the full receive timeout (502 after 15 s on /device/info, 504
after 120 s on a download).  After a mid-download reboot it answered 8.8 s
after its banner -- the one measured readiness point.

startup()'s first POLL now stops waiting the moment the banner arrives (that
POLL will never be answered) and polls again every 2 s for up to 20 s.  Without
a banner nothing changes: a silent unit fails at the normal timeout, with no
re-polling.  Only SESSION_RESET and POLL are sent, so this is safe in front of
the change path too.

No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:17:09 -04:00
serversdownandClaude Opus 5.5 36f4e5d985 feat(sfm): a MiniMate download is checked against the unit's own peaks before it is stored
Series 4 downloads were checked (decoded PVS against the unit's); Series 3's
were stored unchecked (verified=None), so BE9441's two bad files went in as
successes at the bench (2026-10-25).  verify_s3_download(): if the waveform
decodes, all three geophone channels must be the same length and each peak must
be the unit's own 0C peak to one 0.005 in/s step, or the download is refused
(MalformedReply, "not saved").  Unverified (stored, as before): no waveform
decode -- a histogram; 0 of ~430 fixture histograms decode as one -- or a
sensitive-range unit, whose scale is still open.  The reason goes in
detail["check"].

A test puts the metadata-page bug back and the check refuses the file it
produced.  Session-replay helpers move to tests/minimate_replay.py.

No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:14:44 -04:00
serversdownandClaude Opus 5.5 75d79ece6c fix(minimateplus): a one-event download is whole or it is an error
BE9441 rebooted mid-download at the bench (2026-10-25): the chunk at 0x7D06
got one stray byte and then silence, the 5A loop logged "unexpected end-of-
stream -- proceeding to TERM", the TERM got no reply either, and the short event
(17,920 / 17,920 / 17,408 of 21,504 samples) was stored as a success.

read_bulk_waveform_stream(strict=True) now raises on every early end: no STRT,
a metadata page or chunk with no reply, a mid-stream terminator, the chunk cap,
or no TERM reply.  get_events passes it for the strict walks (headers_only,
only_key) and, in strict mode, re-raises a 5A error instead of logging
"metadata unavailable" and returning the event without frames.  The legacy
full walk is unchanged, call for call (strict passed only when on).

Tests replay BE9441's recorded session through the real MiniMateClient: whole,
event 1 comes back in full; with the 5A stream quiet from chunk 40 while the
walk is still answered -- the bench's reboot -- it raises "ended early".

No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:11:13 -04:00
serversdownandClaude Opus 5.5 352f6944e7 fix(minimateplus): a non-first event's 5A stream has no metadata pages -- stop cutting 2 bytes
extract_body_bytes() and write_blastware_file() skipped 13 bytes on A5 frames
1 and 2 unconditionally, as if they were the global metadata pages (0x1002,
0x1004).  Only the event-1 walk fetches those; a non-first event goes straight
from the probe to sample chunks (skip 12), so every non-first event SFM built
lost two bytes and decoded truncated (BE9441 event 1: 1,024 / 2,782 / 512
samples instead of 21,504, peaks far low).  Frames now say which they are: each
A5 reply echoes its address, and both 0x1002 at frame 1 and 0x1004 at frame 2
must match.  Rebuilt from the bench's logged bytes, event 1 decodes 21,504 x 3
with peaks equal to the unit's own 0C values.

Fixtures: BE9441's raw replies for events 0 and 1 (force-added).

Operational: affects only Series-3 files SFM assembled itself (live downloads,
bridges/ach_server.py) for non-first events -- not Blastware's own files, which
is what the production store ingests.  Such files are two bytes short; their
.a5.pkl sidecars can rebuild them.  No DB or schema change; codec unchanged
(TOOL_VERSION not bumped).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 18:05:44 -04:00
serversdownandClaude Opus 5.5 a8cc516601 fix(minimateplus): SUB 0x15's serial is a C string -- cut at the first NUL
BE9441 (MiniMate bench, 2026-10-25) answers b"BE9441\x00?": six characters,
the terminator, a leftover byte.  rstrip(b"\x00") kept the "?", so the serial
read "BE9441\x00?" and the serial-named path refused every request as the wrong
unit (409).  Seven-character serials fill the field to the terminator, which is
why no earlier unit showed it.  The legacy /device/info output is cleaned too.
No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 17:14:11 -04:00
serversdownandClaude Opus 5.5 5527fcd91f docs: correct today's overclaim -- the first *Micromate* commands, not the first ever
4b911b1 (and its subject line) called UM20147's start/stop "the first commands
this project originated".  The retracted CLAUDE.md line was always about Series
4: the minimateplus stack has sent Series-III writes (start/stop, config push,
erase, call-home config) since April 2026.  Narrowed in CLAUDE.md and the
Micromate reference.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 16:40:47 -04:00
serversdownandClaude Opus 5.5 4b911b1c0c docs: the first commands this project originated -- start/stop on UM20147
Bench, 2026-10-25, Brian's go per send: 0x96 acked in 464 ms and read back
monitoring at the first 2 s poll (during the sensor check); 0x97 acked in
116 ms, then 0x49 read a new value 0x01 for ~18 s (inferred: the unit's
call-home attempts after a stop) before idle; two stops to an idle unit acked
in 10 ms and changed nothing.  Retracts "no command has ever been originated"
in place in CLAUDE.md and the reference's untested list; answers the spec's
stop-while-stopped question.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-25 15:56:18 -04:00
serversdownandClaude Opus 5.5 b1c87ecccd docs(spec): what the phase 3 review left open, and why
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 19:36:36 -04:00
serversdownandClaude Opus 5.5 cdc6360ec0 fix(sfm): an audit finish that fails on a hang-up path still releases the line
The final fix wave's AuditIncomplete landed in _exchange's `except DeviceError`,
which keeps the line -- so on the nine ring / link-fault paths (and a refusal) a
failed audit write turned a hang-up into a held Series-4 line, blocking a THOR
call-home for up to the 5-minute idle hang-up and making "SFM hung up" false.
AuditIncomplete now carries release_line, set by every finish whose path hangs
up anyway, and _exchange honours it.  Also pins the Series-3 change path's
retry=False again (the rewritten lost-ack test no longer could).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 19:36:00 -04:00
serversdownandClaude Opus 5.5 8f68b09f5e fix(sfm): a change that fails after the send says so; the audit row records sent + states; S3 unknown states refused
Final fix wave for phase 3 (start/stop monitoring), per the whole-phase review.

- I1 + M2: every failure after the send has started is a ChangeUnconfirmed
  (audit_id, sent = "acknowledged" | "unknown", the cause's HTTP status) whose
  message says the frame was sent and names the audit record -- the ring in
  place of the ack, the four lost-ack follow-ups, and the three read-back
  paths.  Series4Session releases the line on it.  Every audit finish goes
  through one helper; a finish that fails is AuditIncomplete (500) and still
  says what happened to the unit.  The line is kept.
- I2: device_commands gains `sent` (1 acknowledged, 0 nothing sent, NULL
  unknown) and `states` (before / seen / after), with an idempotent ADD COLUMN
  in _migrate for a table created earlier on this branch.
- M1: a RADIO RING already buffered is caught before 0x96/0x97 goes out
  (pre_send = read_unsolicited, one 10 ms transport read).  That is a
  CallHomeInProgress with sent=0, not ChangeUnconfirmed.
- M3: Series 3 reads the raw 0x1C flag (new MonitorStatus.state_flag); a byte
  other than 0x00/0x10, or a short section, is unknown(...) and refused.
- M8: even_if_already on a unit already in the state notes that the read-back
  proves nothing.
- M10: a scan pins `.protocol.execute(` to sfm/device_access/s4.py; both
  scans fail closed on a file that does not parse.
- M11: docs corrected (CLAUDE.md phase-2 sentence, phase-3 bullet, REST list;
  micromate/protocol.py scope and the 0x49 read_state docstring; s4.py; route
  docstrings).  "No command has ever been originated" is NOT retracted.
- M12: GET /db/device_commands normalises the serial.
- Minors: unused imports, S3 dry-run frames and 120 s timeout pinned, test
  rename, serial-cache and short-0x49 tests, _RUN_STATES comment.

Schema: two NULLable columns on the branch-new device_commands table, added
by _migrate on open; no backfill.  No codec change, TOOL_VERSION unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 19:16:45 -04:00
serversdownandClaude Opus 5.5 ac33c8ffa4 fix(sfm): start/stop HTTP status is an allow-list -- only verified, skipped or dry-run is 200
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 17:00:31 -04:00
serversdownandClaude Opus 5.5 c3e7e169c0 feat(sfm): start/stop monitoring by serial -- dry run, audit, read-back
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:57:47 -04:00
serversdownandClaude Opus 5.5 ce5d2cb0d6 feat(sfm): start/stop monitoring for Series 3 through the same safety layer
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:48:05 -04:00
serversdownandClaude Opus 5.5 78c3d568d5 test(sfm): pin the ring-on-follow-up and calling-home poll exits; narrow the refusal clause
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:45:02 -04:00
serversdownandClaude Opus 5.5 14ea80f5a4 fix(sfm): a ring or a refusal is never mistaken for a send; fresh serial pinned; unmeasured states refused
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:39:55 -04:00
serversdownandClaude Opus 5.5 eada7ba767 feat(sfm): start/stop monitoring for Series 4 -- identity, state, dry run, audit, read-back, never retried
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:29:03 -04:00
serversdownandClaude Opus 5.5 ff0cce1cb2 fix(sfm): an audit row can be finished once, from pending -- anything else raises
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:24:46 -04:00
serversdownandClaude Opus 5.5 fb9b48f259 feat(sfm): device_commands audit table -- one row per change attempt
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:22:28 -04:00
serversdownandClaude Haiku 5.5 7ff527df07 feat(micromate): read the unit's run state and refresh its serial on demand
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:20:12 -04:00
serversdownandClaude Opus 5.5 9ed9578d12 test(micromate): an AST scan pins execute() as the only write grant; cover the last mutants
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:17:04 -04:00
serversdownandClaude Opus 5.5 a90b8158b6 fix(micromate): the write ceiling is enforced at the wire; allowed_writes retired; execute takes only real plans
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 16:06:24 -04:00
serversdownandClaude Opus 5.5 8daf413fe3 feat(micromate): execute(plan) -- the only write path, one call's permission, a start/stop ceiling
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 15:58:31 -04:00
serversdownandClaude Opus 5.5 144d3779a1 docs(plan): phase 3 -- start/stop monitoring, the first live write, through the safety layer
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 00:47:12 -04:00
serversdownandClaude Opus 5.5 c6f7b5c031 docs(spec): the ring cool-down is test-first -- bench procedure for the ring path and retries
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-23 00:20:08 -04:00
serversdownandClaude Opus 5.5 75b7694983 docs(spec): phase-3 write preconditions and the measured Series-3 verdict
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 17:48:52 -04:00
serversdownandClaude Opus 5.5 36b6fada3f docs: say exactly what the phase-2 dry run and gate showed
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 17:48:35 -04:00
serversdownandClaude Opus 5.5 f47b908a27 fix(micromate): fixture metadata separates the measured firmware line from the version
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 17:48:20 -04:00
serversdownandClaude Opus 5.5 93349ed040 test(micromate): a checksum landing on any of the four escape bytes is escaped
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 17:48:04 -04:00
serversdownandClaude Opus 5.5 137aa699c7 fix(micromate): a plan step is immutable once validated; setup push checks each block's own header
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 17:47:49 -04:00
serversdownandClaude Opus 5.5 b7b054aee9 fix(micromate): the gate refuses an uncatalogued SUB whatever it is told
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 17:47:25 -04:00
serversdownandClaude Opus 5.5 0e46f3d83f fix(micromate): the call-home plan warns when it leaves THOR's observed values
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 17:47:07 -04:00
serversdownandClaude Opus 5.5 9ecf6e6a0c feat(bridges): mm_dry_run -- a write's planned frames from a live unit's reads; bench-checked on UM20147
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 17:29:00 -04:00
serversdownandClaude Opus 5.5 cbda4b80df fix(micromate): a write plan copies its steps -- nothing can be added after validation
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 17:26:41 -04:00
serversdownandClaude Opus 5.5 49f8f49ac1 feat(micromate): write plans for start/stop, call-home and setup push -- THOR's frames byte for byte
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 17:24:16 -04:00
serversdownandClaude Opus 5.5 c46dd878ff test(micromate): THOR's write sessions as fixtures -- seven captures, paired, with provenance
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 17:22:08 -04:00
serversdownandClaude Opus 5.5 9c1c7cec76 fix(micromate): the opcode gate is an allowlist -- unknown SUBs refused; tables read-only
READ_SUBS catalogues every read; a SUB in neither table is refused, and
allowed_writes may only name catalogued writes.  Tables are MappingProxyType,
_send checks the exact bytes it writes, check_transmit documents precedence.
Tests cover unknown opcodes, concatenation smuggling and table immutability.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 17:19:52 -04:00
serversdownandClaude Opus 5.5 a3e4e85dfd feat(micromate): one opcode table and a send-side gate -- writes refused unless allowed, 0xA2 always
micromate/opcodes.py holds WRITE_SUBS and the cross-series collision 0xA2.
MicromateProtocol._send reads the SUB of the bytes about to go out
(framing.request_sub) and refuses any write SUB not in allowed_writes, and
0xA2 unconditionally.  Docstrings now say the reads-only policy is enforced.

request_sub also refuses any frame not in canonical form
(stuff(unstuff(body)) == body): an interior unescaped 02/03/04, a 10 XX
outside {02,03,04,10}, or a trailing lone DLE.  What the gate checks is then
exactly what the unit parses.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 17:10:23 -04:00
serversdownandClaude Opus 5.5 151ba1546f feat(micromate): build_request carries a data section -- reproduces all 251 THOR request frames
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 17:07:38 -04:00
serversdownandClaude Opus 5.5 2a6acae259 docs(plan): Series-4 write path phase 2 -- encoder, opcode gate, write plans, dry run
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-22 00:14:30 -04:00
serversdownandClaude Opus 5.5 7a6c74266b docs: phase 1b re-review residuals -- bench scope gains the already-stored check, parked items corrected
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:59:25 -04:00
serversdownandClaude Opus 5.5 9a6bfa4d90 test: force-add the two Thor event fixtures the device-access tests read
tests/fixtures/ is gitignored, so these were never committed.  Since phase 1b
the test fakes read them, so on a fresh clone every test that builds a fake
Micromate -- phase 1a's included -- failed with FileNotFoundError.  Same
precedent as tests/fixtures/micromate-setup/: UM20147's own bench events.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:58:18 -04:00
serversdownandClaude Opus 5.5 a130107fdf fix(sfm): a Series-4 record whose timestamp did not decode is not called stale
Mirrors the Series-3 fix (F3): an unreadable 0C timestamp is a decode or
comms fault, not proof the unit was erased.  Nothing is downloaded.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:58:18 -04:00
serversdownandClaude Opus 5.5 67a0fece34 docs(spec): park two more phase 1b items -- a lost 0C in a list, the walk retry
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:45:04 -04:00
serversdownandClaude Opus 5.5 a5ebe8d4b1 docs(spec): park the phase 1b review's open items; scope the owed MiniMate bench check
- New section "Left open by the phase 1b review (2026-10-21)", after the
  1a one: twelve one-line items, each naming the phase it matters to
  (retry re-running a whole download, last_used after a kept-line error,
  verified:null's two meanings, mic naming + the S4 0x0C mic denormal,
  500 detail text, the serial as a directory name, no server-level ring
  test, S3 stored record_type, a fresh S4 download's gaps, orphan files,
  same-second collisions, 423 Retry-After).
- The 1b bullets now give the owed MiniMate bench check's scope: a 3+
  event list (1F(browse) after 1E(arm) without 1F(arm)), a non-first
  event, a histogram (capture its 0C), an event past 64 KB (the named
  502), a stale id (no 5A), and a dropped reply via mm_link-style fault
  injection.
- The 1b "Download" bullet's "refreshes the row" is retracted in place:
  the final review changed it to "returns the row, writes nothing".

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:42:24 -04:00
serversdownandClaude Opus 5.5 2a70faf7b5 docs(sfm): state the held-line invariant, pin the hang-up on a library error, correct the README
- Series4Session's docstring now states which errors keep the line: an
  op raises a DeviceError only for a verdict on a healthy link (not
  found, stale, unnameable), and _exchange keeps the line for those; any
  library error means the link is suspect and hangs up.  DecodeMismatch
  is a library error and hangs up -- conservative.  Later ops must keep
  to it.
- Test: a micromate TimeoutError mid-download, on a fresh DeviceAccess
  (no retry path), is NoAnswer, closes the client once and leaves no held
  line.  It pins existing behaviour; a mutation that keeps the line on
  library errors makes it fail.
- README, event rows corrected in place: another unit's id is 422 (not
  409); a stale id is 409 without downloading, both series; an event
  already stored -- including by THOR's watcher -- returns its row and
  changes nothing (detail.already_stored); MiniMate lists give
  record_type null, on the normal timeout, and fail on a lost reply.

No code behaviour change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:41:26 -04:00
serversdownandClaude Opus 5.5 4e1e6a9d5c fix(sfm): Series-3 events list with no record type, not a wrong one
minimateplus's _extract_record_type returns "Waveform" for every 0C
record layout -- it cannot tell a histogram -- so a MiniMate histogram
was listed as "waveform".  The fake's "Histogram" was a value the real
client never produces, which is why no test saw it.

- _s3_ref: record_type is always None, with
  detail.record_type_note = "Series 3's event record does not say
  waveform or histogram; not decoded yet".
- default_s3_events(): both events "Waveform", as the real client gives.
- The shared-shape contract test allows exactly {"record_type"} to be
  None for Series 3 and nothing for Series 4.

Rows SFM stores for Series 3 still carry "Waveform" from the decode (the
same as the legacy blastware_file route); parked in the spec.  No codec,
store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:40:26 -04:00
serversdownandClaude Opus 5.5 59dff06f1c fix(sfm): the Series-3 header walk fails loudly, and listing uses the normal timeout
One lost 1F reply made the list return 1 of 3 events as a 200, and on a
download gave a false 404.  The list also ran on the 120 s download
timeout, so each lost reply stalled the walk 120 s with the unit locked.

- get_events() strict mode (headers_only, or only_key): a lost 0A reply,
  a lost 1F(browse) reply on the success path and on the partial-record
  path all re-raise their ProtocolError; a 1F that hands back a key
  already walked raises ProtocolError("event chain did not advance ...").
  Legacy calls (none of the new options) behave exactly as before --
  pinned by tests of the same three faults under get_events().
- Series3Adapter.list_events runs on the default timeout (10 s on TCP);
  download_event keeps 120 s.
- FakeProto gains optional lost-reply injection; its default is unchanged.

The repeat-key guard sits at the loop head, which is reached only for a
non-null key -- equivalent to checking each 1F's key, in one place.

Read-only; nothing new on the wire.  No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:39:54 -04:00
serversdownandClaude Opus 5.5 01b9188f25 fix(sfm): a stale Series-3 id is refused before the full download, not after
Series3Adapter.download_event compared the timestamp only after
download_event_by_key had run the whole 5A.  A stale id cost a full
download of the wrong event (minutes on cellular), could surface the
64 KB-page 502 instead of 409, and a lost 0C reply was reported as "the
unit was erased".

- get_events() gains only_key_timestamp: with only_key, if the target's 0C
  says another time (or none), the target takes the existing bypass --
  no 1F(arm), no POLL, no 5A.  A new branch only; it adds no command.
- download_event_by_key(key4, *, expected_timestamp=None) passes it on.
- The adapter converts the id's stamp to that ISO form and checks, in
  order: no event -> 404; no readable 0C timestamp -> 502 MalformedReply
  ("could not read ... record (0C)"); a different time -> 409 StaleEvent;
  no frames -> 502.
- The fake's download mirrors the real walk (no frames on a mismatch) and
  records what it was asked for.
- Legacy get_events() (none of the new options) is pinned by a test of
  its exact call sequence and 5A arguments, written before the change.

Read-only; nothing new on the wire.  No codec, store or DB change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:38:34 -04:00
serversdownandClaude Opus 5.5 157fcc51a7 fix(sfm): a fresh Series-4 download keeps the unit's own PVS and sensor location
Without Thor's TXT report, save_imported_idf fills only the three PPVs.
The unit's 0x0C record -- already read for the list and the stale check --
also gives the peak vector sum and the sensor location, and they were
dropped: Terra-View showed a blank PVS, and find_twins (which matches on
PVS) could not link the event to its histogram twin.

persist_download now overlays DownloadedEvent.record onto the bridged
event before insert_events, filling only fields the file left empty
(creating PeakValues / ProjectInfo when absent).  Not the mic: its 0x0C
decode reads a denormal, parked.

The sidecar is written by save_imported_idf before the overlay, so it
still has no vector sum; the DB row does.  No schema change, no migration.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:36:15 -04:00
serversdownandClaude Opus 5.5 ef096e3082 fix(sfm): a download never downgrades a stored event -- an existing row is returned, nothing written
THOR's watcher (and Blastware's ACH) store every event through
/db/import/idf_file and /db/import/blastware_file, with the paired report.
Storing a download of the same event afterwards overwrote that richer copy:
on Series 4 the file, .h5 and sidecar were rewritten (extensions dropped);
on Series 3 the row lost PVS, project strings and ZC frequencies and was
repointed at a second, review-less file set.

persist_download now looks up (serial, timestamp) first.  A row there is
returned as it stands -- inserted false, detail.already_stored true -- with
no store call, no insert_events and no sidecar write.  Never merge.

- DownloadedEvent gains `timestamp` (the unit's own event time) and
  `record` (Series 4's 0x0C fields); both adapters set them.
- The Series-3 `event is None` guard now runs before backfill/save, with a
  message that is true there ("nothing was stored").
- Tests build the watcher's state exactly as the import endpoints do and
  prove the row dict, the sidecar bytes and the file mtimes are unchanged.

No schema change, no migration, no codec change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:35:23 -04:00
serversdownandClaude Opus 5.5 ddb22d9624 docs(micromate): equal peaks across a histogram/waveform pair are real, not a list bug
Flagged in the phase 1b bench review; settled from the histogram file's own
interval data (5,021 counts vert = the waveform's 1.5581 in/s).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:13:41 -04:00
serversdownandClaude Opus 5.5 89a2a493fb docs: phase 1b bench-checked on UM20147 -- events by serial for both series
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:11:24 -04:00
serversdownandClaude Sonnet 5.5 39e0d312e5 feat(sfm): list and download events by serial for both series
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:07:42 -04:00
serversdownandClaude Opus 5.5 d84204f533 feat(sfm): store a downloaded event -- one ingest for both series
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:04:44 -04:00
serversdownandClaude Haiku 5.5 9e2d8b62c3 feat(sfm): DeviceAccess lists and downloads events for both series
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 17:02:19 -04:00
serversdownandClaude Haiku 5.5 0a01a8d2db feat(sfm): Series-4 events -- chain-walk list, download at THOR's cursor
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 16:59:55 -04:00
serversdownandClaude Opus 5.5 b79309eb72 feat(sfm): Series-3 events -- header list, one-event download, stale ids refused
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 16:57:26 -04:00
serversdownandClaude Opus 5.5 c85244e0fe feat(sfm): event models and event_id -- serial, key and timestamp
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 16:54:53 -04:00
serversdownandClaude Opus 5.5 83d1a98c1c feat(micromate): fetch_event returns the bytes with the checked decode
get_event() now delegates to fetch_event(), which returns (blob, result).
The same peak-vector-sum self-check applies, so a DecodeMismatch still stops
the bytes from being stored. get_event() keeps its signature and behaviour.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 16:52:43 -04:00
serversdownandClaude Opus 5.5 d5484d10c0 feat(minimateplus): list events from headers, download one without the rest
list_event_headers() walks every event's 0A/1E/0C/1F without starting a 5A.
download_event_by_key() downloads one event in full and walks past the others
without their 5A, stopping once it has it. Both ride two new keyword options on
get_events() (headers_only, only_key); the default path is unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 16:50:26 -04:00
serversdownandClaude Opus 5.5 ff7188a034 docs(plan): SFM device access phase 1b -- events for both series
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 16:45:50 -04:00
serversdownandClaude Opus 5.5 6b4161ddfb docs(spec): phase 1b decisions -- header-only MiniMate list, download stores, event_id
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 16:40:31 -04:00
serversdownandClaude Opus 5.5 89433c1fdb docs(spec): every phase lands on this branch; one merge to dev at the end
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 15:35:26 -04:00
serversdownandClaude Opus 5.5 e1af35e1d0 docs(spec): park the phase 1a review's minor findings in the spec
They were recorded only in the plan's scratch ledger, which is deleted
when the plan finishes.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:59:42 -04:00
serversdownandClaude Opus 5.5 278921796a fix(sfm): any request taking the legacy path is refused beside a held line
The /device guard let every non-UM serial through before its held-line
check.  FastAPI drops an undeclared `serial`, so `?serial=BE18193` on a
legacy route still ran Series-3 code at an address holding a Series-4
line -- the hole the guard exists to close.  Serial-aware routes go
straight to DeviceAccess, which refuses that case itself; everything
else is checked.  baud is no longer parsed (it is not in the address
key, and pydantic's coercion made "38400.0" a second way past).

Also, from the same review:
- RingWatchTransport clears its frame state on every write, so a stray
  STX on an idle line cannot hide the ring that answers the next request.
- Series4Session.is_open reads _client once; held_serial() calls it
  without the unit lock, and a concurrent hang-up between two reads was
  an AttributeError (a 500).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:58:57 -04:00
serversdownandClaude Opus 5.5 080e8f4704 docs: serial parameter, settings/hangup endpoints, single-worker rule, cool-down prerequisite for 1c
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:45:33 -04:00
serversdownandClaude Opus 5.5 d393a149f8 fix(sfm): a different UM serial at a held address is refused (409), not swapped
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:45:17 -04:00
serversdownandClaude Opus 5.5 aa79e996c5 fix(sfm): construct the DeviceAccess singleton at import
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:45:17 -04:00
serversdownandClaude Opus 5.5 52ada0215c fix(sfm): RADIO RING detection ignores bytes inside frames
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:45:10 -04:00
serversdownandClaude Opus 5.5 82b91835fb fix(sfm): one guard in front of every /device route -- UM serials 501 off the serial-aware routes, held lines 409 serial-less requests
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:44:35 -04:00
serversdownandClaude Sonnet 5.5 6dd34f8fd7 docs(claude): SFM speaks Series 4 by serial -- phase 1a done, bench-checked on UM20147
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:27:56 -04:00
serversdownandClaude Opus 5.5 e7a5a3cce1 feat(sfm): serial-named /device/info, /status, /settings and /hangup for both series
With serial: one contract for Series 3 and 4 through sfm.device_access.  Without it: the legacy Series-3 path, unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:26:16 -04:00
serversdownandClaude Opus 5.5 73b6089012 fix(sfm): retry once on a dropped held line; refuse Series-3 beside a held Series-4 line
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:23:57 -04:00
serversdownandClaude Opus 5.5 96c7b31f4e feat(sfm): DeviceAccess -- one door, held Series-4 lines, a reaper, and the same answer shape for both series
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:17:39 -04:00
serversdownandClaude Opus 5.5 ece9ec79e3 feat(sfm): Series-4 identify, status and settings into the shared models
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:15:43 -04:00
serversdownandClaude Opus 5.5 8e7333b899 feat(sfm): Series-4 session -- call up once, stay on the line, release on RADIO RING
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:13:34 -04:00
serversdownandClaude Opus 5.5 d39f8ef360 fix(sfm): Series-3 status says its serial is unverified
Series 3 status reads no serial, so the serial shown is the requested one, not one the unit reported. detail now carries serial_verified=False.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:12:17 -04:00
serversdownandClaude Opus 5.5 5c6ca049c8 feat(sfm): Series-3 adapter -- identify, status, settings into the shared models
Connect-per-request with the TCP cold-boot retry kept; a different unit answering is refused (409) whenever the serial is already in hand.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:10:23 -04:00
serversdownandClaude Haiku 5.5 bb4b26835b feat(sfm): per-unit lock -- one connection per unit, 423 when busy
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:08:10 -04:00
serversdownandClaude Haiku 5.5 034529f498 feat(sfm): device_access core -- typed errors, series by serial prefix, shared models
Co-Authored-By: Claude Haiku 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:06:20 -04:00
serversdownandClaude Opus 5.5 fa032567c2 feat(micromate): get_event_count() and read_unsolicited()
0x06 content[0:4] moves from the bench tool into the client, tested against a real UM20147 read and its chain-walk count.  read_unsolicited() reads without sending, for spotting RADIO RING on an idle session.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:04:35 -04:00
serversdownandClaude Opus 5.5 31181f64e6 fix(micromate): is_open() called a property -- TypeError on every real transport
Hidden because the test double defined is_connected as a method; it is now a property, matching BaseTransport.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-21 01:02:32 -04:00
serversdownandClaude Opus 5.5 8eab5f9479 docs(plan): SFM device access phase 1a -- foundation plus identify/status/settings for both series
Ten tasks, test-first: the is_open fix, two client reads, core types, the
per-unit lock, both adapters, Series-4 sessions with ring safety,
DeviceAccess with the reaper and the contract tests, the endpoints, and a
read-only bench check on UM20147.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 19:10:15 -04:00
serversdownandClaude Opus 5.5 bbc6fe2a61 docs(spec): serial-less requests keep today's shapes; phase 1 splits into 1a/1b/1c
Nothing breaks between phases: the shared models apply when a request names
the unit by serial, and the legacy Series-3 path stays as it is until the
webapp (1c) and watch_unit.sh move over.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 19:03:03 -04:00
serversdownandClaude Opus 5.5 68cad4e2ab docs(spec): monitor logs are their own piece of work -- row 6 moves to the parking lot
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 18:54:24 -04:00
serversdownandClaude Opus 5.5 435c1978a0 docs(spec): park setup files and schedules as one open question
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 18:42:41 -04:00
serversdownandClaude Opus 5.5 90171996d6 docs(spec): say plainly what 'no PC-side setup library' means
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 18:38:56 -04:00
serversdownandClaude Opus 5.5 3215c17e37 docs(spec): one user experience for both series -- the guiding principle, applied
Brian's principle: talking to a Series 3 or a Series 4 unit is identical for
the user; only the serial prefix and each model's settings differ, and the
adapters absorb the rest.

Five places the draft broke it, now fixed: units are named the same way
(serial + address, no-serial kept only as a legacy Series-3 path); one set
of series-neutral response models with series-only fields under `detail`;
one opaque event_id for both; a uniform 501 "not supported for Series N
yet" instead of missing routes; and the webapp brought into scope with the
same screens for both.  Adds an adapter table, contract tests that keep the
two adapters honest, and notes that existing Series-3 response shapes move
to the shared models (the webapp updates with them; Terra-View does not
call /device/*).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 18:33:48 -04:00
serversdownandClaude Opus 5.5 1c6aa04687 docs(spec): SFM Series-4 parity and a device safety layer -- design for review
Parity of jobs with Series 3 for regular comms and settings (identify,
status, settings, events, download, monitor log, start/stop, call-home
enable/disable, setup push); Series-4 emergency tools deferred.  A single
device-access layer: series from the serial prefix, identity confirmed
before any write, a per-unit lock, an 0xA2 opcode guard, read-back
verification of every change, distinct error codes, and an audit table.
Series-4 sessions ("stay on the line") now; Series-3 sessions after a bench
test of MiniMate hangup/DCD behaviour.

Includes the fix list found in the 2026-10-19 inventory, the to-be-added
table, and the RX55 container idea as a parking-lot item.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-20 17:41:00 -04:00
serversdownandClaude Opus 5.5 618fcb7770 docs(changelog): Series-4 config decoding -- get_setup(), the 0x1A map, and one checksum rule
Folded into the existing Unreleased sections.

Added: MicromateClient.get_setup() (verified line by line against UM20147's
screen), micromate.setup_block.crc_ok() for 0x1A/0x08/0x2E, the config diff
harness, and the decoded setup in mm_client_check.

Changed: the 0x1A field map; channel blocks 4/5/6 are the active mic and two
stored mic setups; 0x1A reads the edit buffer and a load replaces it
byte-for-byte; the unit's own conversion constants (3.2808, 2.21); 0x08 is
preferences; the geophone scale confirmed from the unit's config; the 0x1C
sub-second tick; the never-write-modem-baud rule; two corrected 16-byte slips;
and the Series III anchor hypothesis, flagged inferred with no code change.

Fixed: the watcher overwriting previous sessions, and two stale bench-tool
labels.

Migration stays None -- additive modules only, no codec/store/DB change, no
TOOL_VERSION bump, no backfill.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-19 18:41:35 -04:00
serversdownandClaude Opus 5.5 fa017b0ee7 merge: Series-4 config decoding -- the setup block mapped from the keypad, and get_setup()
Closes the gap the 10-13 recap named: config blocks were fetched but barely
read.  Two keypad passes on UM20147 (10-17, 10-19), every byte that moved
attributed to a setting the operator named, then the map turned into code.

MicromateClient.get_setup() reads SUB 0x1A once and returns a MicromateSetup
-- record mode, sample rate, histogram interval, pre-trigger, stop mode,
record time, auto-stop, active sensors, trigger sources, trigger levels, mic
type and level, job number, scaled distance, notes.  Measured fields only.
Every value matched UM20147's screen.

Findings that shape what comes next:

1. ONE CHECKSUM RULE (CRC-16/AUG-CCITT) covers 0x1A, 0x08 and 0x2E -- a free
   integrity check on every config read.  Thor's write omits it; the unit
   computes it, so it is not a write obligation.

2. LOADING A SETUP REPLACES THE ACTIVE CONFIG BYTE-FOR-BYTE, and 0x1A reads
   the keypad's edit buffer live.  The name is the only link between a file
   and its contents, and even its spelling varies (.MMB / .mmb).

3. THE SIX CHANNEL BLOCKS ARE 3 GEOPHONES + THE ACTIVE MIC + TWO STORED MIC
   SETUPS.  Read the mic from block 4 only.

4. THE UNIT CONVERTS UNITS WITH ITS OWN CONSTANTS (ft / 3.2808, lb / 2.21).
   Convert back with them or 45 lb reads 44.89.

5. 0x08 IS THE PREFERENCES BLOCK; display units live there and never touch
   the stored setup values.

6. NEVER WRITE MODEM BAUD OR MODEM TYPE REMOTELY -- the remote link is the
   modem port.

INFERRED, Series III, no code changed: S3's 6-byte "stable anchor" sits where
Series IV keeps pre-trigger + stop mode, so an S3 unit in Auto stop mode may
lose it.  One Blastware capture in Auto mode settles it.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-19 18:40:28 -04:00
serversdownandClaude Opus 5.5 6bd45b56ec docs(claude): get_setup() exists -- the checksum is wired in, not pending
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-19 18:20:39 -04:00
serversdownandClaude Opus 5.5 b3aff4ed66 feat(micromate): get_setup() -- the setup block decoded, checksum-verified, and read off a real unit
MicromateClient.get_setup() reads SUB 0x1A once and returns a MicromateSetup:
record mode, sample rate, histogram interval, pre-trigger, stop mode, record
time, auto-stop, active sensors, trigger sources, the three geophone trigger
levels, mic type and (linear) mic trigger, job number, scaled distance, and
the four notes.  MEASURED FIELDS ONLY -- everything graded inferred or
unknown in the reference stays in .raw.

micromate/setup_block.py holds the decode as pure functions (no I/O), plus
crc_ok(): one checksum rule for 0x1A, 0x08 and 0x2E.  A failed checksum
raises SetupChecksumError (a ProtocolError) unless verify=False; a short
block raises either way.

Two things the decoder gets right that a naive one would not:
- the mic comes from channel block 4 (the ACTIVE mic), never blocks 5/6,
  which hold the stored settings of whichever mic is NOT fitted;
- distance and charge weight convert back with the unit's own 3.2808 and
  2.21, so 45 lb entered on the unit reads 45.0, not 44.89.

TESTS: 69 new.  15 real fixtures (2,103 B each) -- 14 UM20147 reads from the
10-17/10-19 keypad passes, chosen so every field takes at least two values,
plus UM12947's read from Thor's 9-24 capture (other firmware line).
Expected values are what the operator read off the unit's screen, never the
decoder's own output.  Fixtures force-added, per the tests/fixtures/
convention.  Full suite 541 passed; the 16 pre-existing failures
(test_bw_ascii_report.py 15, test_event_file_io.py 1) are unchanged.

VERIFIED ON HARDWARE: bridges/mm_client_check.py now prints the decoded
setup; against UM20147 every line matched the unit's screen (Brian, 10-19).

Also: the scratch harness uses the library checksum and checks all three
blocks; mm_client_check's stale labels fixed (0x06 content[4:8] is the
likely monitor-log count, not "unexplained"; 11.0BD is no longer "the first
one this code has met").

No codec, store or DB change; no backfill.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-19 18:20:25 -04:00
serversdownandClaude Opus 5.5 a74d3c9b00 docs(series4): loading a setup is an exact replacement -- plus the prefs block, a checksum rule, and the firmware's own unit constants
23 more snapshots of UM20147, keypad-driven.

MEASURED: loading a .MMB replaces the active config byte-for-byte -- three
loads, each moving exactly the fields that differ, the loaded block identical
to the file's saved state, no load marker.  The setup name's spelling
(.MMB/.mmb) depends on whether it was saved or loaded.

MEASURED: job number [40:42], report flags [39] (0x02 job no., 0x08 scaled
distance; 0x01 unknown); distance [30:34] in metres and charge weight
[34:38] in kg, converted bit-exactly with ft / 3.2808 and lb / 2.21 -- the
firmware's own constants, not the textbook ones.  Scaled distance is not
stored.  Location confirmed at [144].

MEASURED: 0x08 is the preferences block (display units at content[31]),
not an event index; switching units moves nothing in 0x1A.  0x1A, 0x08 and
0x2E share one checksum rule (N = content[0:2]; CRC over [0:N-2] at
[N:N+2]); 0x2C has none.  0x2C session timeout is at [118:120], encoding
unknown; modem baud is in none of the six blocks.

CORRECTED IN PLACE: the 9-24 notes-label offset (0x8A -> 0x7A) and
channel-block start (0x06BC -> 0x06AC), both 16-byte slips.

RULE: never write modem baud or modem type remotely -- the remote link is
the modem port.

No codec, store or DB change; no backfill.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-19 17:30:37 -04:00
serversdownandClaude Opus 5.5 7c010e42a4 docs(claude): leave the next config step written down -- load a setup and diff it
Brian's hypothesis from the end of the 10-17 pass: selecting a .MMB
repopulates the active config, so a single load moves every field that
differs between two setups -- a check of the whole map in one step.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-17 02:41:13 -04:00
serversdownandClaude Opus 5.5 56b8aac4cb docs(series4): the 0x1A field map from a keypad pass -- a CRC, an edit buffer, and three mic blocks that are not channels
47 snapshots of UM20147 while settings were changed on its own keypad, one
at a time.  Every byte that moved is accounted for; nothing outside 0x1A
moved.

MEASURED (operator named setting + values): record mode [5] (01 Waveform,
02 Manual, 03 Histogram, 04 Combo -- S3's encoding, one byte later than the
S3 analogy put it), sample rate [6:8], histogram interval [8:10] s,
pre-trigger [12:16] f32 negative s (all four values), stop mode [17], record
time [18:22] f32, auto-stop [23], active-sensor and trigger-source bitmasks
[25]/[29], trigger level at channel +30 (geo in/s, mic psi).

MEASURED: the trailer is CRC-16/AUG-CCITT over content[0:2088] -- 47/47 and
a second unit.  Thor's write omits it, so it is read-side integrity, not a
write obligation.

MEASURED: blocks 1-3 are geophones, block 4 is the ACTIVE mic (a byte copy
of 5 or 6), 5 and 6 are the stored linear / SLM mic setups.  No separate
mic-type byte; block 4's +4:8 code is the type.  Promotes the 10-15 "+4
channel type" guess; retracts "+46:48 is a trigger-source flag" in place.

MEASURED: 0x1A reads the keypad's edit buffer live; discard reverts;
commit timing differs by widget (list / spinner / sub-window).

INFERRED, Series III: the 6-byte "stable anchor" sits exactly where Series
IV keeps pre-trigger (-0.25 s) + stop mode (Fixed).  An S3 unit in Auto
stop mode would lose it and decode no mode/rate/interval/record time.  Not
measured on S3; noted in instantel_protocol_reference.md, code untouched.

No codec, store or DB change; no backfill.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-17 02:22:00 -04:00
serversdownandClaude Opus 5.5 75cbe23214 fix(micromate): config watcher no longer overwrites the previous session -- and checks the 0x1A CRC
`watch` saved every session as `watch-000..NNN`, so each run silently
overwrote the last.  Harmless while those snapshots were clock ticks; data
loss once they were findings.  Labels now default to `watch-MMDD-HHMM-NNN`
(`--prefix` overrides).

Each 0x1A change also prints its trailer check: CRC-16/AUG-CCITT over
content[0:2088], stored BE at content[2090:2092].  Measured on 47/47
snapshots of UM20147 plus UM12947's 9-24 capture; a mismatch means a short
or corrupt read, or a layout this does not assume.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-17 02:22:00 -04:00
serversdownandClaude Opus 5 ba021df6b2 docs(claude): say where config decoding actually stands -- set up, waiting on a keypad press
"Where things stand" said config decoding "needs a bench session varying one
setting at a time -- not desk work", which was true when written and now sends a
reader off to build tooling that exists.  This is the same staleness that had
the file claiming micromate/ had no live client.

What it now says, because these are the things that cost time to rediscover:

- The harness is scratch/mm_config_diff.py and the baseline is already captured.
- THE METHOD IS VERIFIED VIABLE: all five config blocks are bit-stable, so any
  byte differing between two snapshots IS the setting.  That was the open
  question about whether the Series III approach transfers at all.
- Start with SAMPLE RATE.  A large distinctive power of two pins endianness in
  one shot; a boolean toggle moves one byte 0 -> 1 and teaches nothing.
- The keypad works.  No Windows VM, no contending for the modem's single TCP
  session.
- `sg dialout -c` is required to open /dev/ttyACM0, because the group membership
  exists in /etc/group but not in shells started before it was added -- AND THE
  FAILURE LOOKS LIKE A DEAD UNIT, which is worth a line on its own.
- watch-001..005 on disk are clock ticks, not findings.
- channel+24 = 3.1030800342559814, independently confirming _GEO_LSB_IPS to
  1.1e-8 and 32,226.05 counts exactly.
- The rest of that channel map is GRADED and the grades are load-bearing: +4
  "channel type" and the +8:24 uint16 split are single-setup guesses, recorded
  as guesses on purpose.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-16 19:09:58 -04:00
serversdownandClaude Opus 5 66171ffe36 docs(series4): the 0x1A channel blocks -- graded, because one of these is strong
and two are guesses

Six 48-byte channel blocks at content[1708], stride exactly 48: Tran, Vert,
Long, Mic, LMic, SMic.  (Mic is 3 chars, so a 4+-printable scan misses it and
the stride looks like 96 across that gap.)

RECORDED IN THREE EXPLICIT GRADES, because I wrote them in one voice first and
that is the failure mode this reference already carries retractions for -- the
0x0C float from a single sample, the cost model fitted to sub-1 KB responses,
offset detector v1.  All three were an interpretation presented with the
confidence of a measurement.

MEASURED, and the one worth having: channel+24 is a float32 BE reading
3.1030800342559814 on all three geo channels.  Divided by 10,000 that is
0.00031030800342559815 -- the documented _GEO_LSB_IPS to 1.1e-8.  It implies
10.0/3.10308 = 3.222605 V full scale, which at 10,000 counts/V gives 32226.05
counts, the documented figure exactly.

That is an INDEPENDENT confirmation of a number that until now rested purely on
statistical inference: _GEO_LSB_IPS was pinned by intersecting 991,415 rounding
constraints from Thor's own CSV exports.  The unit reports it directly.  Two
unrelated derivations agreeing to eight digits.  It is also almost exactly half
Series III's 6.206053 (ratio 1.99997, the residual being S3's rounded display
value).

Also measured: the units strings ("in."/"/s.", "psi"/"(L)", "dB"/"(A)") are
literal ASCII, and Tran/Vert/Long are byte-identical EXCEPT +47, which reads
0x01 on Tran and Vert and 0x00 on Long.

INFERRED (one setup, one unit): that +24 is the calibration constant rather than
another field holding the same number -- the arithmetic proves the number, not
the field's purpose; and that +47 is an enable or trigger-source flag.

GUESSED, explicitly flagged not to build on: +4 as a uint32 "channel type", from
six correlated observations in a single setup; and +8:24 as eight uint16 BE
values, where the split itself is an assumption.

TOOLING FIX in the same commit, from a real miss: the volatile baseline ran four
reads over eight seconds, so it never crossed a minute boundary and never saw
the minutes byte.  Five "changes" then came in a row that were just the clock.
Hours and the date would have slipped through identically.  An empirical noise
floor only catches what moves WHILE sampling, so 0x1C's known clock span
(content[2:10]) is now seeded regardless, and the report says which bytes were
observed versus seeded.  Memory-free is deliberately left unmasked -- it moves
only when the unit records, which is worth being told about.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-15 14:35:54 -04:00
serversdownandClaude Opus 5 711277131a feat(micromate): a config diff harness -- and the blocks turn out to be bit-stable
The Series III config map was built by changing one setting and seeing which
bytes moved.  Whether that method transfers to Series IV depended on an
unmeasured question: how much of a config block moves ON ITS OWN.  If a block
carries a clock or a counter, every diff arrives polluted and there is no way to
tell the real answer from the noise in a single pair.

MEASURED ON UM20147 (11.0BD), FOUR READS BACK TO BACK, NOTHING TOUCHED:

  0x1A compliance    2103 B    0 bytes moved
  0x2C call home      137 B    0
  0x2E trigger         39 B    0
  0x08 event index    101 B    0
  0x01 device info    163 B    0
  0x1C monitor status  59 B    2  (and those two are explained below)

Every config block held every byte still, so the method transfers directly and
needs no noise floor subtracted.  That was the open question.

scratch/mm_config_diff.py drives it: `volatile` establishes the floor, `snap`
saves a labelled read of all five blocks, `diff` reports changed runs with each
plausible field interpretation (u8/u16be/u32be/f32be) and reports any volatile
bytes separately rather than silently hiding them.

CORRECTION TO content[6] OF 0x1C, long recorded only as "NOT the hour": it is a
sub-second tick, ~4020 counts/second in steps of exactly 4, wrapping at 256 --
about a 64 ms period, consistent with the low 6 bits of a millisecond counter.
Consequence worth knowing: a 0x1C block is never byte-identical to itself, so
any "has the status block changed?" check answers yes ~15 times a second.
Compare named fields, never whole blocks.

I nearly recorded that byte wrong, and the trap is cheap enough to document:
sampled once per second it reads as a smooth monotonic counter at ~16/s with a
16-second wrap.  Twelve consecutive samples supported it.  It is aliasing -- a
64 ms counter read once a second is noise that happens to look tidy.  Measure a
counter back to back before trusting any rate from spaced samples.

Also: the settings do not have to be changed from THOR.  The unit's own keypad
works, which needs no Windows VM and does not contend for the modem's single
TCP session.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-15 12:28:40 -04:00
serversdownandClaude Opus 5 4c29820831 docs(changelog): the Series-4 call-home session, and two more corrections
Folded into the existing Unreleased sections.

Added: bridges/mm_ach_server.py, flagged as implementing the listener path only.

Changed: the captured ACH session (101 frames, every command already
implemented bar one); the two call-home paths and what decides between them; the
0xA2 collision with series III's CONFIRM ERASE; monitor-while-calling-home
blocking erase while THOR reports success; THOR rewriting unit IPs from the
call-home source; and the CLAUDE.md refresh.

Fixed: mm_client_check misreporting its own request count, the ACH server
buffering its output and leaving modem chatter as a hex dump, and .gitignore
missing capture artefacts beside tracked bridge source.

TWO ENTRIES CORRECT THIS FILE'S OWN EARLIER TEXT, which is the part worth
reading: 0x06 content[4:8] was recorded here as "a constant, 9 on both units"
and is the monitor-log count; SUB 0x49 was recorded as two states and has three.

Migration stays None -- no codec, store, DB or schema change and no TOOL_VERSION
bump -- but the note now says explicitly that THE 0xA2 COLLISION IS DOCUMENTATION
RATHER THAN A FIX.  minimateplus can already send 0xA2 as the last step of its
erase sequence, and nothing yet stops a future shared path confusing the two
meanings.  A guard is outstanding, and a reader deciding whether this release is
safe deserves to know that.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-15 00:06:45 -04:00
serversdownandClaude Opus 5 8b48b3f42b merge: the Series-4 call-home session, captured end to end
Closes the last protocol unknown.  A MITM between UM12947's modem and THOR
1.5.0.29 captured a complete working ACH session: 101 request frames, 101
responses, 0 bad checksums, 34,872 B of event data in 65 seconds.

EVERY COMMAND IN A REAL ACH SESSION IS ONE micromate/protocol.py ALREADY
IMPLEMENTS -- POLL, BULK_DOWNLOAD, STATE, EVENT_RECORD, EVENT_NEXT,
STORAGE_RANGE, MONITOR_STATUS, ARM_EVENT, SERIAL, EVENT_FIRST -- bar one.

Three findings that change how a receiver must be built:

1. CALL-HOME HAS TWO PATHS, decided by who holds the modem's single TCP
   session.  If something is already connected, the unit's RADIO RING travels up
   THAT connection; if nothing is, the modem dials out to a listener.  THOR's
   UnitWatchDogTimer reconnects continuously, so THOR usually holds the slot --
   which is why probes and relays saw "connected, no reply" all afternoon.  That
   was contention, not a fault.

2. SUB 0xA2 ENDS A CALL-HOME ON SERIES IV AND IS CONFIRM ERASE ON SERIES III.
   Same opcode, same 0x5D response, opposite consequence.  minimateplus and
   micromate already share a transport, so any shared path must dispatch on
   series before that byte reaches a wire.  This is a hazard in code that
   already ships, which is the main reason this merge should not wait.

3. "MONITOR WHILE CALLING HOME" SILENTLY BLOCKS ERASE, and THOR reports the
   session successful anyway.  A receiver therefore cannot rely on erase to
   manage storage -- the server-side high-water mark is load-bearing, and the
   condition is detectable from event count plus free memory on every call.

Two corrections to entries made earlier this month: 0x06 content[4:8] is the
monitor-log count rather than a constant, and SUB 0x49 has a third state (0x03,
in-call-home) which is why that flag is tested for non-zero.

bridges/mm_ach_server.py implements the LISTENER path only and says so; the
poller half -- holding outbound connections and watching for the ring -- is the
next piece of work.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-15 00:05:47 -04:00
serversdownandClaude Opus 5 9c8eb5c5b8 docs(claude): refresh "Where things stand" -- it claimed there was no live client
Stale since 2026-09-26, and wrong in two ways that matter to anyone picking the
project up:

- "micromate/ still has no live client -- it is codec-only."  There has been a
  full client since 2026-10-02: framing/protocol/client + models, 119 tests,
  verified on hardware across both firmware lines and both transports.
- "the inbound call-home session is the only protocol unknown left."  It was
  captured end to end on 2026-10-14.  There are no protocol unknowns left.

Replaced with the current state, and added the three things a reader most needs
up front: that ACH has TWO paths decided by who holds the modem's single session
(so silence from a probe is usually contention with THOR, not a fault); that
0xA2 ends a call-home on series IV and CONFIRMS ERASE on series III across a
shared transport; and that monitor-while-calling-home blocks erase while THOR
calls the session a success, which makes the server-side high-water mark
load-bearing.

Also named the real remaining gap honestly: config decoding, not protocol.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-14 19:51:46 -04:00
serversdownandClaude Opus 5 7645c91ae2 docs(series4): monitor-while-calling-home blocks erase, and THOR calls it success
Manual 11.4.4: a Micromate can call home WHILE IT CONTINUES TO MONITOR, or pause
monitoring and send.  UM12947 is on the former, which is why the captured session
logged "CANNOT DOWNLOAD MONITOR LOG" and "CANNOT DELETE ALL EVENTS -- The unit is
monitoring".

THOR REPORTS THAT SESSION AS "SESSION COMPLETED SECCESSFULLY" ANYWAY.  The
refusals are INFO lines.  From outside, a unit quietly accumulating looks
identical to one being managed correctly.

Correcting my own framing from earlier today: I flagged "Delete Events and Logs
from Unit = Yes" as a risk to the test data.  It is TMI's normal and necessary
fleet setting -- without it a unit fills up and re-offers every event on every
call.  A unit left on monitor-while-calling-home is the misconfigured one, and
drifts toward a full buffer by itself.

DESIGN CONSEQUENCE FOR SFM: a receiver cannot rely on erase to manage storage.
The erase can fail for a reason the unit considers normal, so the server-side
high-water mark is LOAD-BEARING rather than an optimisation -- it is the only
thing preventing a full re-download every session.  Series III's ach_state.json
(downloaded_keys / max_downloaded_key) is the pattern and has to carry over
deliberately.

Also a detectable fleet-health signal: "memory filling AND deletes refused" is
visible on every call from 0x06's event count and 0x1C's memory fields.  Worth
surfacing precisely because THOR calls it success.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-14 18:37:10 -04:00
serversdownandClaude Opus 5 08d2d31a09 docs(series4): a complete ACH session captured -- and 0xA2 is a loaded gun
MITM between UM12947's modem and THOR 1.5.0.29: 101 request frames, 101
responses, 0 bad checksums, 34,872 B of event data in 65 seconds.

EVERY COMMAND IN A REAL ACH SESSION IS ONE WE ALREADY IMPLEMENT -- POLL, SERIAL,
STORAGE_RANGE, MONITOR_STATUS, STATE, ARM_EVENT, EVENT_FIRST/NEXT, EVENT_RECORD,
BULK_DOWNLOAD -- except one.

SUB 0xA2 ENDS A CALL-HOME, AND COLLIDES WITH SERIES III'S ERASE.  The session's
final command is 0xA2 at offset 0xFFFF, answered 0x5D, and THOR's log at that
instant reads "StartMonitoringAfterCallhome / Switching unit back to monitoring".
So on series IV it means exit call-home and resume monitoring.

On SERIES III, 0xA2 -> 0x5D is CONFIRM ERASE -- the last step of
0xA3/0x1C/0x06/0xA2, after which the unit's memory is cleared.  Same opcode, same
response SUB, opposite consequence.  This is the most dangerous collision found
in this protocol: minimateplus and micromate already share a transport, and
sending 0xA2 to a MiniMate Plus to "end a session" erases it.  Any shared path
must dispatch on series before that byte goes near a wire.

It also corroborates the firmware string found by static analysis in September,
CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING.

TWO CORRECTIONS TO EARLIER ENTRIES OF MINE:

- 0x06 content[4:8] was recorded on 2026-10-01 as "9 on both units regardless of
  count -- a constant, not a count".  It reads 47 here, where THOR's log twelve
  minutes earlier reported "Monitor Log count: 45" on the same unit.  It is
  almost certainly the monitor-log count; both units reading 9 just meant both
  held 9 records.

- SUB 0x49 was recorded as 0x00 idle / 0x02 monitoring.  It reads 0x03 throughout
  this session, ten for ten -- a distinct in-call-home state.  Precisely why the
  rule is "test for non-zero": a client checking == 0x02 would call a unit
  mid-call-home idle.

Also softened the claim that mm_ach_server is "built on the wrong model".
ListenerAchTcp HAS now accepted a connection -- when nothing else holds the
modem's single session, the unit dials out and the listener takes it; when THOR
already holds a connection, the ring rides that instead.  Both paths are real.
The listener model is valid, it just loses the race against anything already
connected -- which explains every failed probe and relay attempt today as
contention rather than bugs.

And noted: THOR rewrites a unit's stored IP from the call-home source address, so
a relay silently poisons THOR's record of where that unit lives.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-14 18:35:38 -04:00
serversdownandClaude Opus 5 8f67608e0f feat(micromate): answer a RADIO RING the way THOR does -- SERIAL, immediately
THOR's ACH log exposed two differences between what it does on seeing a ring and
what we were doing, and either could explain why the unit never answered us:

              | ours              | THOR
  command     | POLL (0x5B)       | ReadSerialNumber (0x15)
  delay       | 8 s (grace window)| 36 ms

We sat silent for the whole grace window and then asked a different question.
The unit may well have given up long before we spoke.

So the grace window now ENDS THE MOMENT a RING is seen, and the ring is answered
with SERIAL first -- which is THOR identifying which unit rang before doing
anything else.  The push-vs-pull experiment the window was built for is
unaffected: silence still runs the full duration.

This does not change the bigger finding that mm_ach_server is built on the wrong
model for a PAD-connected unit -- THOR's working path is a POLLER holding an
outbound connection, not a listener.  But if a unit whose modem dials out can be
made to answer on the inbound path too, that is worth knowing before the rewrite,
and it costs two small changes to find out.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-14 18:12:14 -04:00
serversdownandClaude Opus 5 90ac7ff76a docs(series4): SOLVED -- call-home is an in-band wake signal, not a dial-out
From THOR's own ACH log, 4,414 lines, UM12947 over an RX55.  This overturns the
model this document has carried from the start and explains every confusing
result of the past weeks.

A MICROMATE DOES NOT DIAL ANYBODY.  It emits the ASCII string "RADIO RING" over
its serial port, and that text travels up a TCP connection THE SERVER ALREADY HAS
OPEN TO THE UNIT.  The server recognises it and runs a session on that same
connection.

  17:18:17  TcpClientSystemNet    #1: RADIO RING IS RECEIVED FROM IP:63.45.161.30 Port:9034
  17:18:17  ListenerAchRadioRing  #2 RADIO RING IS DETECTED
  17:18:17  ConnectorWorkerThread Process Request: ReadSerialNumber
  17:18:18  ListenerAchRadioRing  #3 RADIO RING UNIT SERIAL NUMBER = UM12947
  17:18:18  ACHManager            #8 RADIO RING STARTED A NEW SESSION

TcpClientSystemNet is THOR's outbound TCP CLIENT -- the ring arrives on the
connection THOR itself opened to unit:9034, the ordinary call-UP path.  No
inbound connection, no dial, nothing to accept.  THOR keeps that connection alive
on purpose: UnitWatchDogTimer reconnects continuously, 1,039 log lines in 37
minutes.

THOR's OTHER ACH path was never used.  ListenerAchTcp logs "Waiting for a ACH
connection on Port 12346" and in 4,414 lines NEVER ACCEPTED ONE.  All twelve ACH
events came through ListenerAchRadioRing.

CONSEQUENCE: bridges/mm_ach_server.py is built on the wrong model for this
deployment.  It listens for an inbound connection -- ListenerAchTcp's model, the
one THOR never exercises here.  The right shape is a POLLER that holds an
outbound connection to each unit, watches the stream for RADIO RING, identifies
the unit, and runs a session on the same socket.

That also dissolves the single-session contention that dogged every experiment
today: the receiver must hold the modem's one session slot PERMANENTLY.  Our
probes and MITM attempts were not fighting a bug, they were fighting the design.

Also captured: the full ACH state machine (15 steps), the eight request types
with counts, and two corroborations -- StartMonitoringAfterCallhome matches the
firmware string found by static analysis in September, and ReadEventRecordCount
returning "Event count: 19" independently supports the SUB 0x06 event-count
finding.

Flagged, unexplained: events are addressed as 90000001 (length 4076) in THOR's
ACH path, where our chain walk returns 055d4a81 for an event of exactly that
length.  Same event, different address space.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-14 17:55:50 -04:00
serversdownandClaude Opus 5 52d18b0d5d docs(series4): OBSERVED -- THOR's ACH side is POLL, byte-identical to ours
First capture of THOR's half of a Micromate call-home, taken with ach_mitm.py
between UM12947's modem and a THOR 1.5.0.29 ACH server on port 8070.

THOR sends POLL (SUB 0x5B, offset 0x0030) and NOTHING ELSE -- four times over
~21 s, then gives up.  No greeting, no answer to the RADIO RING, no CONNECT.

And that POLL is BYTE-IDENTICAL to what micromate.protocol builds:
build_request(SUB_POLL, 0x0030) reproduces all four frames exactly.

So the ACH session is PULL, and bridges/mm_ach_server.py already implements it
correctly.  The "inbound call-home session" -- carried for weeks as the last
protocol unknown -- was never a separate protocol at all.  It is the ordinary
command set on an inbound socket, exactly as series III's 72 captured sessions
suggested it would be.

THE OPEN PROBLEM IS NOW CLEARLY ELSEWHERE.  In the same capture the unit sent
only "RADIO RING", four times, and never a protocol frame.  THOR polled four
times and got nothing -- identically to our own server in three attempts the
same afternoon.  THE VENDOR'S OWN SOFTWARE FAILS THE SAME WAY WE DO, which
eliminates the receiver as a suspect and places the fault between modem and
unit.

Established: cellular healthy (151 ms connect, outbound dial works), bytes do
reach us from the unit's side, modem serial config matches spec (115200 8N1, no
flow control, PAD/TCP), cable is FTDI and cold-booted with it attached.  Not
established: whether the unit or the modem emits "RADIO RING" -- it is the
literal string in this unit's own 0x2C dial-string field, and the cheap
disambiguation is to disconnect the unit and see if it still appears.

Next step is a config diff against a working deployed unit's modem, not more
protocol work.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-14 16:42:18 -04:00
serversdownandClaude Opus 5 fc0a7b2a88 chore: ignore capture artefacts beside the bridge scripts
A stale Windows checkout had ten March-era capture files staged as new and
deleted from the working tree -- .bin/.log/.set artefacts in bridges/ and
bridges/s3-bridge/ that .gitignore never covered, since it only had
/bridges/captures/.

Deliberately NOT ignoring /bridges/s3-bridge/ wholesale: proxy.py and
s3_bridge.py live there and are tracked.  Only the artefact extensions.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-14 16:33:44 -04:00
serversdownandClaude Opus 5 3fa2a4035e fix(micromate): the ACH server now names modem chatter, and flushes its output
Three things the first real call-in exposed.  UM12947's modem dialled in at
14:16:56 from 63.45.161.30 -- the network path works -- and sent 60 bytes of
"RADIO RING", space-padded and newline-separated, four times.

1. THAT IS MODEM CHATTER, NOT THE UNIT, and the server left it as a hex dump to
   interpret by hand.  CLAUDE.md already records that an RV50/RV55 "sends
   \r\nRING\r\n\r\nCONNECT\r\n over TCP to the caller even with Quiet Mode
   enabled"; an RX55 on AirLink OS says RADIO RING instead.  The server now
   recognises the known modem strings and says so.

   ⚠ The diagnostic value is in what was MISSING: four RINGs and NO CONNECT.
   RING means the modem is ringing the serial device, CONNECT means something
   answered.  Rings without a connect, plus no answer to POLL, means TCP is fine
   and the unit is not on the other end of the serial link.  The server now
   prints that conclusion and the three things to check -- cabled at all, cable
   chipset (FTDI/CDC-ACM only, never Prolific), and a cold boot with the cable
   attached, since the USB-A host port only enumerates at power-on.

2. STDOUT WAS BLOCK-BUFFERED.  With output redirected, every print sat in a
   buffer, so the log read EMPTY while a call was in progress and the session was
   only discoverable on disk afterwards.  For a tool whose whole job is to be
   watched during a one-shot event, that is close to useless.  Line-buffered now.

3. THE DOCSTRING PROMISED SCANNERS LEAVE NO TRACE ON DISK, AND THEY DID.  The
   failed-handshake path created a session directory unconditionally -- my own
   loopback sanity check produced one.  Now a connection that sends nothing AND
   fails the handshake is discarded with no directory; one that sent something
   unprompted is always kept, because that is the interesting case.

Also recorded in session.json: modem_chatter, ring_count and a diagnosis string,
so a session can be triaged without re-reading the raw bytes.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-14 14:21:42 -04:00
serversdownandClaude Opus 5 67de2c18da fix(tooling): mm_client_check reported THOR's request count, not its own
The download line computed `size // 1024` -- THOR's chunk size -- while the
download used the 16 KB default.  So a 72,560 B event that took 5 requests was
printed as "71 chunks", and I nearly read a working 16 KB download as a broken
1 KB one.  A diagnostic that misreports what it did is worse than one that says
nothing.

Now prints the real count and the size used: "5 req @ 16384 B".

Verified by counting the frames in a capture of that run: 5 x SUB 0x5A at
offsets 0x4000 0x4000 0x4000 0x4000 0x1b70, summing to exactly 72,560.  That is
also the FIRST time the 16 KB chunk size has run through the real download loop
on hardware -- previously only the probe had issued 16 KB single requests, and
the loop itself had only been exercised at 1024 B against THOR's frames and at
16 KB against simulated responses.

Also recorded: USB identification for the Micromate's own ports.  Its PC port is
2504:0300 (Instantel Inc. MICROMATE COM PORT), appearing as CDC-ACM, against
0403 FTDI and 067b Prolific for the USB-A host-port cables.  Address it by
/dev/serial/by-id/ and not /dev/ttyACM<n>, because the number moves whenever
another CDC-ACM device appears -- which has already cost a session aimed at a
TMI-Seismo MCU by mistake.

And: passing one through to a Proxmox guest hot-plugs with no VM restart via
`qm set <vmid> -usb0 host=2504:0300`.  UM20147 is now on tmi-dev (10.0.0.44)
this way, which means the unit can be driven from the dev VM directly instead of
relaying commands.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-14 12:46:01 -04:00
serversdownandClaude Opus 5 bdf4909d2a docs(series4): no Micromate has ever been observed calling home
Correcting an implication I made.  The 72 ach_inbound_* sessions in
bridges/captures/ are MiniMate Plus, and I framed the Series III ACH setup as
though it transfers to a Micromate.  It is not known to.

What we actually have for Series IV is prior, not observation:

- THOR manual 6.2 and the firmware's own strings
  (CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING, "Call Home Deleting
  Events") say the unit dials in and waits to be told what to do -- server-driven,
  the same shape as Series III's pull model.
- UM12947's 0x2C dial string reads literally "RADIO RING", which is modem ANSWER
  vocabulary rather than a destination.  With the RV50 debug string
  ATQ1 ATE0 ATS0=2 ... RADIO RING -- ATS0=2 being auto-answer-after-2-rings --
  that reads as the unit arranging to ACCEPT calls, i.e. the call-UP path.  Which
  argues the ACH destination lives in the modem, as it does for series III.

If both priors hold, mm_ach_server.py is just MicromateClient on an inbound
socket and the unknown evaporates.  But there is a specific failure mode worth
naming in advance:

THE MICROMATE DEMONSTRABLY TALKS AT TO ITS MODEM.  If it drives an AT dial for
call-home, that exchange happens on the SERIAL LINK and a TCP listener sees none
of it.  So the first experiment has an AMBIGUOUS NULL -- no connection could mean
the trigger did not fire, or that the interesting part is invisible from the
network.  The escalation is a serial-level capture between unit and modem, not
more fiddling with the server.

Recorded in both the protocol reference and the server's own docstring, so
whoever runs the experiment reads the caveat before being puzzled by a silence.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-03 01:54:31 -04:00
serversdownandClaude Opus 5 4579896b6d feat(micromate): inbound ACH server -- and the push-vs-pull experiment
The inbound call-home session is the last unmapped part of the Series IV
protocol, and it may well not be a separate protocol at all.  Series III's
answer, from the 72 ach_inbound_* sessions on disk, is that the unit DIALS IN AND
THEN WAITS: ach_server.py accepts the socket, wraps it in SocketTransport ->
MiniMateClient, runs the ordinary handshake and drives with the ordinary command
set.  If Series IV behaves the same way, this file is just MicromateClient
attached to an inbound socket.

THE ONE QUESTION THAT MATTERS IS PUSH VS PULL, and no packet capture can answer
it -- you have to connect and keep quiet.  So the server says NOTHING for --grace
seconds after accepting.  Bytes in that window mean the unit speaks first, and it
reports the hex, the ASCII, and whether they parse as a response frame (series III
sends an "Operating System" banner on cold boot, so a banner is the likely shape).
Silence means pull, and the normal handshake follows.

READ-ONLY, and deliberately more so than its series III sibling: that one has
"rescue actions" that stop monitoring and disable ACH on a runaway unit, and
those are absent here.  No command has ever been originated against a unit by
this project, and an inbound session is the worst place to break that.  --depth
defaults to walking the event chain WITHOUT downloading.

Captures land as raw_bw_*/raw_s3_* so scratch/mm_frame_parse.py reads the pair
with no arguments, plus a session.json recording what was learned -- including
the push flag, which is the result worth keeping.  The session directory is
created only after the handshake succeeds, so a port scanner leaves nothing on
disk.

Smoke-tested both paths against a fake unit that dials in: PULL detected over
silence and driven to a full chain walk (33 frames, 0 bad checksums, parses with
the existing tool), and PUSH detected from a 10-byte banner with the frame-parse
attempt reported honestly as "none parsed".

Worth recording for the setup: for series III the call-home DESTINATION lived in
the MODEM's config (ACEmanager), not in the seismograph.  If that holds for the
RX55 then nothing on the instrument needs changing, which keeps the no-writes
line intact.  If it has to come from the unit, its 0x2C block holds a 40-byte
dial string -- and writing that is THOR's job, not ours.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-03 01:25:53 -04:00
serversdownandClaude Opus 5 263daa0f96 docs(changelog): the Series-4 event chain, and two corrections to this file
Folded into the existing Unreleased sections.

Added: the event chain (list_events / iter_events / download_event / get_event /
decode_error) with the 74-frame replay test behind it, the per-event PVS decode
self-check, and 0x06 as the event count.

Changed: 16,384 B per request with the byte-driven loop the silent clamp forces;
the retraction of the 0x5A streaming mode; and the hardware verification across
both firmware lines and transports, including that event keys collide across
units.

Fixed: the 64 KB download cap, and the probe's own control being circular.

TWO OF THESE CORRECT THIS FILE'S OWN EARLIER ENTRY, which is the part worth
reading:

- The previous entry stated "~0.65 s per round trip, regardless of payload" and
  drew the advice "minimise round trips, not bytes".  Measured against a 14 KB
  response, cost is ~0.21 s + bytes/2,350.  Every sample behind the old claim was
  under 1 KB, so the byte term was small and uniform and per-command cost looked
  constant -- a narrow-range fit extrapolated past its evidence.  The advice now
  splits: status work is round-trip bound, downloads are throughput bound, and
  the 16 KB chunk size is a ~30% win rather than 14x.

- The previous Migration note said nothing under micromate/ was touched, which
  the preceding merge had already made false; this merge changes the download
  loop as well.  Still Migration: None -- no codec, store, DB or TOOL_VERSION
  change, and no shipped path calls the loop that changed.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-02 19:28:18 -04:00
serversdownandClaude Opus 5 4a11eadc91 merge: the Series-4 event chain, a 64 KB cap closed, and a cost model corrected
Step 4 of docs/micromate_client_spec.md plus what measuring it turned up.
Read-only throughout; still nothing in this project has ever originated a
command against a unit.

The event chain: MicromateEventRef, list_events(), iter_events(),
download_event(), get_event() and decode_error().  The load-bearing test replays
THOR's captured six-event session and asserts every byte we emit matches its 74
frames, while decoding all six events and cross-checking each waveform's peak
vector sum against the float the device computed itself.

Three things hardware found that captures could not:

1. A 64 KB DOWNLOAD CAP, one event away from biting.  The 0x5A chunk offset was
   a uint16 because every offset THOR sends fits in two bytes; UM20147 holds a
   72,560-byte event.  params[0:4] is one 4-byte field (chunk 0 puts the key
   there), so a uint32 is byte-identical below 65,536 and reaches past it.
   Confirmed on the unit: 71 chunks, exact size.  This is the Series III 64 KB
   page-boundary bug wearing a different hat, and that one is still open.

2. NO 0x5A STREAMING MODE -- retracted.  The offset field is simply a byte count
   and the device returns offset + 11 bytes in one frame.  But the probe that
   killed the hypothesis showed 1024 B is THOR's choice, not the device's limit:
   the ceiling is 16,384, and above it the device CLAMPS SILENTLY with correct
   bytes and no error.  That is why the download loop now tracks its offset by
   bytes received rather than striding by chunk index.

3. CELLULAR COST IS NOT INDEPENDENT OF PAYLOAD.  I had it as ~0.65 s per round
   trip regardless of size and built design advice on it.  Measured against a
   14,176 B response: t ~ 0.21 s + bytes/2,350.  The old figure was right for a
   1 KB response and was a narrow-range fit extrapolated past its evidence --
   every sample behind it was under 1 KB.  Status work is round-trip bound;
   downloads are throughput bound, so 16 KB chunks save ~30%, not 14x.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-02 19:27:15 -04:00
serversdownandClaude Opus 5 338ce4fea7 docs(series4): CORRECTED -- cellular cost is NOT independent of payload
I had it as "~0.65 s per round trip, independent of payload size", and based
design advice on it ("minimise round trips, not bytes").  The first claim is
wrong and the second is too strong.

Every measurement behind it had a SMALL payload -- 59 B status, 266 B setup
records, 1024 B download chunks.  With the byte term small and similar across all
of them, per-command cost looked constant.  It was a narrow-range fit
extrapolated past its evidence.

Measured against a 14,176 B single response on UM12947 over an RX55:

  1,024 B   0.67 s      8,192 B   3.59 s
  2,048 B   1.22 s     14,176 B   6.25 s
  4,096 B   2.13 s

  t ~ 0.21 s + bytes / 2,350   -- fits within +/-11% over a 14x size range

The old 0.65 s figure was right FOR A 1 KB RESPONSE and is that model evaluated
at 1 KB.  Round trips still cost (0.21 s each; 24 of them for a setup walk is
still 16 s), but bytes cost more than round trips on anything over ~500 B, and
that reverses the advice: for STATUS work minimise commands, for DOWNLOADS the
floor is throughput and batching does not beat it.

So the 16 KB chunk size is a ~30% win, not 14x.  UM20147's 72,560-byte event is
~46 s at THOR's 1024 B and ~32 s at 16,384 B, because ~31 s of it is bytes on the
wire.  Still worth keeping -- 30% faster, and 14x fewer requests is 14x fewer
chances for a link to drop mid-download -- but the earlier "~3.2 s" projection
was wrong and is withdrawn.

Corrected in all four places it had propagated: the protocol reference, the
CHUNK_SIZE comment, the probe's verdict, and mm_client_check's banner.  The probe
now also prints a net time per measurement, since its raw timings include the
idle gap while the control reads to frame completion -- comparing them directly
was misleading.

Also confirmed in the same run: 16 KB-class responses survive a cellular PAD.
1,024 / 2,048 / 4,096 / 8,192 / 14,176 B all arrived in one frame, byte-identical,
over an RX55.  14,176 B is UM12947's largest event so the ceiling itself was not
reached, but a 14 KB response crossing the PAD intact is what needed proving.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-02 15:09:38 -04:00
serversdownandClaude Opus 5 eefc846c8c scratch(micromate): pin the probe's control to THOR's 1024, not the new default
The probe compared each candidate request size against a "known-good" download
that used micromate's DEFAULT chunk size -- which is now 16,384.  That makes the
experiment circular: if 16 KB is broken on a given link, the reference is broken
the same way and every comparison passes.

The control is now pinned to THOR_CHUNK_SIZE.  1024 is the size with THOR's own
captures behind it and the only one proven over a cellular modem, so it is the
thing to measure against.

Also raised the default idle gap from 2 s to 3 s.  A 16 KB response is ~1.4 s of
serial time at 115200 before the modem's ~1 s forwarding delay, and too small a
gap makes a slow link look like a clamp -- which would read as a device limit
that is really a timeout.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-02 15:00:02 -04:00
serversdownandClaude Opus 5 423608ccd1 perf(micromate): 16 KB per request, not 1024 -- 14x fewer round trips
The chunk-size ceiling, measured on UM20147 with every size checked
byte-for-byte against a known-good download:

  1024 / 2048 / 4096 / 8192 / 16384  ->  served in full
  32768 / 65535                      ->  SILENTLY CLAMPED to 16384

The clamp is the important part: a 32,768 B request returns 16,384 B of perfectly
good data and no error.  Nothing in the response says it was truncated; the
length is the only signal.

THAT DICTATES HOW THE LOOP MUST BE WRITTEN.  read_event_file() now tracks its
offset by BYTES RECEIVED rather than striding by chunk index.  A fixed stride
would either fail on a clamp or skip the bytes it never collected; tracking what
actually arrived makes a clamp cost one extra request, and makes the loop
self-correcting against any short response -- precisely the failure mode that has
bitten the Series III side repeatedly.

Consequence of that change, recorded because it reverses an earlier decision: a
short chunk is NO LONGER AN ERROR.  It used to raise, on the principle that a
silently short event is this codebase's recurring bug.  But the device returns
short legitimately, and the real protection is the offset arithmetic plus the
final total-length check -- which still raises on a genuinely truncated event.
The test was rewritten rather than deleted, and says why.

CHUNK_SIZE = 16384.  For UM20147's events: 4,796 B goes 5 requests -> 1,
30,230 B goes 30 -> 2, and 72,560 B goes 71 -> 5.  Over cellular at ~0.65 s per
round trip that is ~46 s -> ~3.2 s on the large one.

Measured on one unit over USB, so THOR_CHUNK_SIZE = 1024 stays available and the
replay tests pin it -- reproducing THOR's exact traffic is one argument away, and
client.download_event()/get_event() take chunk_size for a link where large
responses are not surviving.

Full suite: 472 passed, 16 pre-existing failures unchanged.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-02 14:14:02 -04:00
serversdownandClaude Opus 5 248ddc9cda docs(series4): RETRACTED -- there is no 0x5A streaming mode; offset is a byte count
Measured directly on UM20147.  offset 0x1014 (4,116) returned one frame of 4,127
B data = 4,116 B of file; offset 0x111c (4,380) returned 4,391 B = 4,380 B.  So
`offset` is simply a BYTE COUNT, the device returns exactly offset + 11 bytes in
one frame, and page_key is offset // 256.  `0x1000` is not a bulk-stream marker;
it is part of the number.  One model now covers every 0x5A request ever observed,
THOR's and ours.

The 2026-09-23 note that offset_word = 0x1000 + 2*pages returned an entire 11 KB
event is therefore wrong -- 0x102C is 4,140, and 4,140 bytes is what it would
have returned.  Most likely the 11,049 figure was the whole capture rather than
one frame's payload.  Those captures never landed in the repo so the error cannot
be traced further, and does not need to be: the live measurement is unambiguous.

The probe tried BOTH escapings of offset_hi, which is why this negative counts --
a malformed frame would have produced the same silence.  The escaped form
answered, so the uniform escape set holds for 0x10 in offset_hi too, and the
Series III exception does not carry over.

AND THE NEGATIVE TURNED UP SOMETHING BETTER.  In establishing that offset is a
byte count, the unit served 4,380 bytes in a SINGLE frame.  1024 is THOR's
choice, not the device's limit.  Since a round trip costs ~0.65 s over cellular
regardless of payload, and a 72,560-byte event is 71 requests ~ 46 s at THOR's
chunk size, the ceiling is worth knowing precisely: the offset field is a uint16,
so 65,535 B per request would make that same event 2 requests, ~1.3 s.

mm_stream_probe.py repurposed to walk ascending request sizes, checking each
against a known-good chunk-loop download so a pass means byte-identical output
rather than a plausible length.

micromate/protocol.py still uses 1024 -- THOR's value, the one with captures
behind it.  Raising it is a one-constant change once the ceiling is MEASURED, and
it should not be raised on inference.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-02 01:28:43 -04:00
serversdownandClaude Opus 5 18ed1a27be scratch(micromate): differential probe for the 0x5A streaming mode
Downloads the SAME event twice -- once with the verified chunk loop, once with a
single offset_hi = 0x10 request -- and diffs the bytes.  A differential test
rather than a suggestive one: byte-identical output means the streaming form is
safe to adopt, anything else tells us exactly what it is instead.

Why it is worth asking: a round trip over cellular costs ~0.65 s regardless of
payload, so UM20147's 72,560-byte event is 71 chunks ~ 46 seconds.  If one
request fetches it, that becomes under a second.  Our 2026-09-23 probes recorded
exactly that behaviour with offset = 0x1000 + 2*ceil(size/512), but those
captures never landed in the repo and cannot be re-derived.

IT TRIES BOTH ESCAPINGS OF offset_hi, and that is the point of the design.  On
Series III, `offset_hi = 0x10` in a 5A frame must be written RAW -- doubled to
`10 10` the device SILENTLY IGNORES the frame, which is a documented rule for
this exact command.  The Micromate escapes 0x04 in that position (218/218
captured THOR frames), which argues the uniform set applies to 0x10 as well, but
Series III is a direct counter-example in the same command.  Testing one form
risks concluding "no streaming mode" when the real finding is "that frame was
malformed" -- so a null result here only counts because both were tried.

Defaults to the SMALLEST event, as the gentlest first attempt; --event largest is
the one that matters.  Ends by re-POLLing, because the honest risk of this
experiment is leaving the session wedged and the script should say so rather than
leave it to be discovered later.

Read-only.  0x5A is a read we have sent thousands of times; the only new thing is
a value in its offset field.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-01 23:39:47 -04:00
serversdownandClaude Opus 5 faac59b283 verify(micromate): the uint32 chunk offset is confirmed -- 72,560 B in 71 chunks
UM20147's event 055d4a83 downloaded at exactly its promised size over USB,
exercising the carry into params[1] on chunks 64-70.  The uint32 reading was
inference for one commit; it is now evidence, and the 64 KB cap that would have
made this event unfetchable is closed.

Worth noting what the same run prices: 71 chunks x ~0.65 s is roughly 46 SECONDS
for one 72 KB histogram over cellular, against 0.2 s over USB.  That is the
round-trip cost model doing real work -- the bytes are nothing, the commands are
everything.  A unit holding several events this size is a multi-minute call, so
the untested single-request offset_hi = 0x10 streaming mode (which would collapse
a download to one round trip) moves up the list.

Docstrings and the protocol reference downgraded from "inference" to "confirmed"
only where the hardware actually settled it.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-01 16:18:30 -04:00
serversdownandClaude Opus 5 0cfec2f098 tooling(micromate): --event selects what to download, incl. 'largest'
The tool downloaded only the first event, which on UM20147 is a 4,796 B
histogram -- so it could not reach the 72,560 B event that is the whole point of
the uint32 chunk-offset change.

--event takes a key in hex, 'first', 'largest' or 'all'.  'largest' is the one
worth running on an unfamiliar unit, since it is what exercises offsets past
64 KB; the output flags any event over 64 KB as carrying into params[1], and
prints the chunk count so a 71-chunk walk is visible as such.

Selected events are downloaded from inside iter_events(), so the chain cursor
sits where THOR's would -- non-selected events are walked past without a
download, which the browse walk already attests is fine.

Also: connect() returning nothing now prints a hint rather than just a bare
timeout.  /dev/ttyACM* numbering shifts whenever another CDC-ACM device is
plugged in, and this cost a debugging session when the tool was aimed at a
TMI-Seismo MCU instead of the Micromate.  `ls -l /dev/serial/by-id/` names each
device and is stable, so the hint says so.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-01 16:04:21 -04:00
serversdownandClaude Opus 5 9c28b586bb fix(micromate): the 0x5A chunk offset is a uint32 -- a 64 KB cap was one event away
UM20147 holds a 72,560-byte event.  chunk_params() wrote the offset as a uint16
at params[2:4], because every offset THOR was observed to send fits in two bytes
(largest 0x3400 = 13,312), which caps a download at 65,536 B -- so that event
could not have been fetched at all.

params[0:4] is demonstrably ONE 4-byte field: chunk 0 puts the 4-byte event key
there.  Writing the offset as a uint32 BE in the same slot is BYTE-IDENTICAL for
every offset below 65,536, so nothing verified against THOR's 74 captured frames
changes -- the replay test still matches all of them -- and the range extends to
4 GB.

Above 64 KB this is inference and the docstring says so: the field's width is
established, the device's handling of a non-zero high byte is not.

Also newly reachable: at offset 1 MiB params[1] is 0x10, which must go out as
`10 10`.  Nothing below 64 KB can produce that, so the uint32 change is what
first makes the case possible -- and an unescaped 0x10 in 5A params is the exact
bug that cost the Series III walk a release.  Tested.

THIS IS THE SERIES III 64 KB PAGE-BOUNDARY BUG WEARING A DIFFERENT HAT.  There,
parse_strt_end_offset() discards the key's page byte and the walk crashes once a
unit's buffer crosses 64 KB; that one is still open.  The transferable lesson:
an address field whose high bytes are zero in every capture is not a narrow
field, it is an untested one.  Same mistake, found twice, in code written years
apart.

Confirmed in the same run: 0x06 content[0:4] IS the event count -- UM20147 holds
5 events and reads 5, making it three for three across both firmware lines
(0->0, 6->6, 5->5).  And content[4:8] is a CONSTANT, not a count: it reads 9 on
a unit with 6 events and on a unit with 5.  list_events() still walks to the
sentinel; the count is worth adopting as a pre-check, not a replacement.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-10-01 00:41:08 -04:00
serversdownandClaude Opus 5 15be9eafdb tooling(micromate): exercise the event chain, and test the 0x06 count candidate
mm_client_check now drives the step-4 client methods rather than the protocol
layer directly -- list_events(), iter_events(), get_event() and decode_error()
-- so a bench run exercises the code that will actually be used.

Prints each ref with the filename it would be stored under, and reports the PVS
self-check result per event.  The download uses iter_events(), which reproduces
THOR's interleaved order.

Adds the 0x06 test: reads storage range BEFORE the chain walk, prints
content[0:4] as the candidate event count and content[4:8] as the unexplained
companion value, then reports AGREES or DISAGREES against the chain length.
Two samples on one unit said the count is right; a third value from a different
unit either confirms it or kills it, and the tool now answers that in one run.

The 0x06 read is wrapped in the same step() helper as everything else, so a unit
that does not answer it degrades to a FAILED line rather than aborting the run.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-30 18:48:58 -04:00
serversdownandClaude Opus 5 d7d72cadf8 feat(micromate): the event chain -- walk, records, download, and a self-check
Step 4 of docs/micromate_client_spec.md.  MicromateEventRef plus list_events(),
iter_events(), download_event(), get_event() and decode_error().  14 new tests;
112 micromate tests total.

The load-bearing test replays THOR's captured six-event download session through
iter_events() + get_event() and asserts EVERY BYTE WE EMIT MATCHES THOR'S, in
order -- 74 frames -- while decoding all six events and cross-checking each
waveform's peak vector sum against the float the device computed itself.

Two design decisions worth recording:

1. iter_events() EXISTS BECAUSE THOR INTERLEAVES.  Its captured order is
   0x93 -> 1E -> 0C -> 5A*n -> 0x93 -> 1F -> 0C -> 5A*n, downloading each event
   before advancing the chain.  list_events() walks to the end first, which is
   fine for browsing but leaves the device cursor parked past the event a later
   download addresses.  0x5A is key-addressed so it very probably does not care
   -- but nothing observed says either way, so the interleaved path is the one
   offered for downloads, and it is the one the replay test exercises.

2. get_event(verify=True) RECOMPUTES THE PEAK VECTOR SUM from the decoded
   samples and compares it against the device's own 0x0C float.  Two independent
   computations over the same samples, so a disagreement means our decode is
   wrong.  Agreement on the bench events is 0.000%.  Cheap insurance in a
   codebase whose decode failures have historically been silent -- unhandled
   block tags shorten a channel and nothing raises.  It is a decode-correctness
   check, NOT a truncation detector: a channel cut after its peak still yields
   the right PVS, and the docstring says so.  A test corrupts a stored peak to
   prove the check actually fires.

MicromateEventRef.uid is SERIAL:key, because the key alone is ambiguous across
units, and .filename generates THOR's name (<serial>_<YYYYMMDDHHMMSS>.IDFW/H)
-- returning None rather than guessing when the record type is unknown, since
read_idf_file() dispatches on exactly that suffix.

Recorded as a CANDIDATE, not used: 0x06 content[0:4] looks like the EVENT COUNT
-- 6 on a unit holding 6 events, zeros on an empty one, and THOR reads it BEFORE
the walk then downloads exactly six events without ever reading the chain
sentinel.  If it holds it lets a caller decide whether to walk at all, which
over cellular is the useful part.  Two samples on one unit, and content[4:8]
reads 9 unexplained, so list_events() still walks to the sentinel: slower by one
round trip and correct on evidence rather than inference.

Full suite: 465 passed, 16 pre-existing failures unchanged.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-30 18:29:32 -04:00
serversdownandClaude Opus 5 e95d8e3b8c docs(changelog): Series-4 live client, verified on hardware
Folded into the existing Unreleased sections rather than adding new headings.

Added: the three new micromate/ modules with 98 offline tests, the hardware
verification across both transports and both firmware lines, and
bridges/mm_client_check.py.

Changed: the six spec rules the captures refuted before any code shipped; the
0x0C peak-vector-sum resolution and the decoder self-check it enables; the
~0.65 s per-round-trip cellular cost and what it implies for design; event keys
colliding across units; and setup names being spelled three ways by three
commands.

Fixed: scratch/mm_frame_parse.py accepting either checksum rule, which is why
it could not falsify either.

Migration: None -- corrected the previous entry's claim that nothing under
micromate/ was touched, which this merge makes false.  The new modules are
additive, micromate/idf_file.py (the codec) is untouched, no TOOL_VERSION bump,
and no backfill is owed.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-30 14:33:10 -04:00
serversdownandClaude Opus 5 af8eebd724 merge: Series-4 live client -- framing, protocol and read client, verified on hardware
The Series-4 live half of SFM: micromate/{framing,protocol,client}.py with 98
offline tests, driven against two real units over both physical transports.

Read-only throughout.  No command has ever been originated against a unit by
this project -- every write in the protocol reference was performed by THOR
while we recorded, and keeping that true through the read client is deliberate.

Six errors in docs/micromate_client_spec.md were found by measuring against the
captures before writing code rather than after.  All six fail silently:

  * requests need FOUR escaped bytes, not one (161/218 frames without)
  * the response checksum is plain SUM8, not the DLE-aware variant (55/251)
  * SUB 0x5A is a 1024-byte chunk loop, not one request per event
  * SUB 0x0A is the monitor-log walk, not a keyed event-header read
  * 1E/1F carry token 0xFE at params[7]
  * SUB 0x01 has no THOR precedent at all

Hardware verification: identical wire bytes over USB CDC-ACM and an RX55 in PAD
mode; every 11.0BD inference confirmed on UM20147; a monitoring unit answers
reads with no SESSION_RESET; and all six bench events decode with the existing
IDF codec.

Two findings that constrain SFM's design rather than just documenting a unit:
cellular costs ~0.65 s PER ROUND TRIP regardless of payload, and event keys
COLLIDE ACROSS UNITS, so any store must key on (serial, event_key).

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-30 14:31:23 -04:00
serversdownandClaude Opus 5 a5237bb3b4 docs(series4): RESOLVED -- the 0x0C float is the PER-SAMPLE peak vector sum
Exact to 0.000% on all four bench waveforms, against a PVS recomputed from the
decoded samples.  The offset (Tran label - 12) is now established rather than
inferred: four independent confirmations plus a fifth on the other firmware
line.

RETRACTION.  The previous entry observed the float running 2-5% above
max(T,V,L) and concluded it was NOT the peak vector sum, "because computed PVS
runs higher than both".  That computed PVS was sqrt(T^2+V^2+L^2) from the three
REPORTED CHANNEL PEAKS, which is an upper bound on the real quantity rather
than the quantity -- the channel maxima do not occur at the same instant, so
combining them overstates the true peak.  Every row of the old table is in fact
consistent with max(T,V,L) <= stored <= sqrt(sum of squares).

I also got this wrong in the other direction today and want it recorded.  On
UM20147's event the stored float matched sqrt(sum of peak squares) to 0.048%,
and I called it the vector sum on that basis.  It is not -- that event's peaks
merely happen to be nearly coincident in time.  The six CB events separated the
two formulas immediately, with errors to -9.5%.  ONE SAMPLE AGREEING WITH A
FORMULA IS NOT EVIDENCE WHEN A SECOND FORMULA FITS IT EQUALLY WELL.

Why it is worth having: it is a FREE SELF-CHECK ON THE DECODER.  The device
computed this number from the same samples we decode, independently of our
codec, so a mismatch means the decode is wrong.  Given this codebase's history
of silent channel truncation -- walker bugs that shorten a channel and raise
nothing -- a per-event invariant costing one float comparison is cheap
insurance, and worth wiring into the download path.

Also added the full 0x0C field map from real UM20147 bytes: timestamp, the
record-type byte, sensor-location label, setup name, serial, the PVS float and
the four channel labels with their offsets.

Noted in passing: the setup name appears as "test2" in 0x0C, "test2.MMB" in
0x41 and "test2.mmb" in 0x40 -- three commands, three spellings of one file, in
one session.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-30 14:27:31 -04:00
serversdownandClaude Opus 5 7d1b033a05 docs(series4): BD download works -- and event keys COLLIDE across units
UM20147, event 055d4a81, 4,796 B, type read as histogram from the 0x0C byte and
decoded as .IDFH on the first try.  The chunk walk, the offset arithmetic, the
11-byte chunk prefix and the record-type byte all hold on the Thor firmware
line unchanged.  That closes the last BD gap.

The type byte is now 7 events across both firmware lines -- 4 waveform, 3
histogram -- correct every time.  Still not a large sample; the fallback stays.

THE FINDING THAT MATTERS: UM20147's first event key is 055d4a81.  So is
UM12947's.  Different units, different sizes (4,796 vs 4,076 B), different
contents, identical key.

This confirms keys are a sequential counter, and adds the consequence: the
counter starts from the same value on every unit, so a key is MEANINGLESS
WITHOUT ITS SERIAL.  Anything that stores, deduplicates or addresses Series IV
events must key on (serial, event_key).  A store keyed on the event key alone
silently treats one unit's event as a duplicate of another's, and the failure is
invisible -- the second event is simply never ingested.

Series III has a related hazard the ACH server already handles: its counter
resets after an erase, so keys are reused WITHIN a unit, which is why
ach_state.json tracks max_downloaded_key per serial.  Series IV inherits that
and adds cross-unit collision on top.

Incidentally resolved: memory free is a usable signal after all.  Run 1 showed
15,000,000 free and no events; run 3 showed 14,799,296 free, idle, with events
stored.  The earlier ambiguity was monitoring overhead confounding it, not
memory being meaningless.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-30 14:24:03 -04:00
serversdownandClaude Opus 5 080fb92ba2 test(micromate): real 11.0BD fixtures replace the synthesised ones
UM20147 captured over USB with mm_client_check.py --capture, read out with
scratch/mm_frame_parse.py: 11 frames each direction, 0 bad checksums.  The two
BD-specific response data sections are now verbatim fixtures; only the frame
wrapper is rebuilt, which is sound because the framing is verified 251/251
elsewhere in the same file, and the reconstruction is pinned against the
payload length the parser reported.

Every field lands where the forward-offset model says it should:

  data[0]        = 0x30 = 48 = 59 - 11   (CB declares 0x2C = 44; the +4 holds)
  content[1]     = 0x0e   monitoring
  content[2:10]  = 30 Sep 2026 14:00:49  matches the wall clock
  content[34:36] = 3.50 V
  content[36:44] = 15,000,000 total / 14,848,448 free

AND THE WARNING IS NOW DEMONSTRATED ON THE UNIT IT PREDICTED.  Series III reads
battery from data[-10:-8], which on this block is e1 c0 -> 577.92 V.  That is
the exact figure the A/B section named, and there is now a test asserting it,
so the reason the offsets are forward cannot be quietly refactored away.

Two corrections to the reference:

1. The four extra BD bytes are `0f a0 00 04`, not `0f a0 00 00`.  Only the
   first two look fixed.  Nothing reads them, but the last is not padding.

2. POLL content[3] VARIES BETWEEN UNITS -- 0x50 on UM12947, 0x56 on UM20147.
   It is printable in both cases ("P" and "V"), which is a second, independent
   reason the POLL block cannot be parsed by scanning for printable runs: a
   scan returns "PInstantel" on one unit and "VInstantel" on the other.  The
   fixed offset content[4] was the right call for a reason I had not seen.

The model string sits at content[26] on both firmware lines; only its tail
differs, so anchoring on "MM/" remains correct.

98 micromate tests pass.  Full suite unchanged at 16 pre-existing failures.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-30 14:08:27 -04:00
serversdownandClaude Opus 5 ea229ed19d docs(series4): monitoring reads confirmed, and setup-name case is inconsistent
Two findings from a UM20147 run that was only meant to capture fixture bytes.

1. A MONITORING UNIT ANSWERS READS NORMALLY.  UM20147 was read while actively
   monitoring -- monitoring=True on both indicators, which agree -- and served
   POLL, serial, state, monitor status and a 5-entry setup walk with no special
   handling.

   This confirms the SESSION_RESET finding with our own client.  Series III
   REQUIRES a bare 41 03 before POLL or a monitoring unit will not answer over
   TCP.  That was inferred from its absence in THOR's captures; it is now
   demonstrated directly, on the other firmware line, by a client that never
   sends one.  (THOR's refusal to send a SETUP while monitoring is a write
   restriction -- reads are unaffected.)

   Monitoring moves two values, so neither is stable to compare against:
   battery drifted 3.55 -> 3.50 V and memory free 15,000,000 -> 14,848,448.

2. SETUP-NAME CASE IS NOT CONSISTENT BETWEEN COMMANDS.  Same unit, same
   session, same file: 0x41 reported "test2.MMB" and 0x40 reported
   "test2.mmb".  A run 45 minutes earlier reported "test2.mmb" from both, so it
   is not fixed per command either; what changed between is that the unit
   started monitoring.

   Cause is a guess from two samples.  The consequence does not depend on it:
   compare setup file names CASE-INSENSITIVELY.  An exact-string test of "is
   the active setup one I know about?" answers no on this unit.  Worth fixing
   before it is a field bug, since name matching is on the path for anything
   that replaces THOR's setup/scheduler coupling.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-30 14:02:32 -04:00
serversdownandClaude Opus 5 b55e4e946a verify(micromate): 11.0BD confirmed on hardware -- every inference held
UM20147 read over USB by mm_client_check.py.  The Thor firmware line was
entirely inference until now, and two of its three differences were covered
only by SYNTHESISED test frames.  All three held:

- flags = 0x03 identifies the line -> reported firmware_line="thor".  That is
  only reachable if `10 03` in the flags position destuffs before indexing,
  since 0x03 is ETX -- so the escaped-flags case is confirmed too.
- the model string is shorter -> reported "MM/ISEE/S" exactly.  Anchoring the
  search on b"MM/" rather than a fixed span is what made this work.
- the 0x1C block is 4 bytes longer with the extras TRAILING, so from-the-start
  offsets survive -> battery 3.55 V and a clock correct to the second.

That last one is the one that mattered.  Series III's from-the-end offsets
would have given this unit 577.92 V, which is why mm_client_check watches for
an impossible voltage: it is a free self-check on exactly the inference most
likely to be wrong.

Also clean: serial UM20147, 5 setups (factory.MMB -> test2.mmb), active setup
test2.mmb, 15,000,000 B total and free, 21 reads / 2,165 B in.

"One protocol stack drives the whole fleet regardless of firmware line" -- the
headline finding of 2026-09-23 -- is now demonstrated by a working client
rather than by matching response SUBs.

Test and docstring claims downgraded from inference to confirmed where the
hardware settled them, and left as synthesised-frame notes where it did not:
the BEHAVIOUR is confirmed but raw BD bytes are still not in the repo.

Added --capture DIR to mm_client_check: writes a raw_bw_*/raw_s3_* pair in the
layout scratch/mm_frame_parse.py already reads, so a run on an unfamiliar unit
becomes a test fixture without setting up a relay.  Verified by round-tripping
its own output through that parser: 28 frames, 0 bad checksums.

Still not covered: a download from a BD unit (UM20147 had no events stored, so
the chunk walk remains CB-only), raw BD fixture bytes, a monitoring unit, a
nearly-full buffer, and the inbound call-home session.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-30 13:17:53 -04:00
serversdownandClaude Opus 5 0d6eb1621f verify(micromate): read client works on real hardware, both transports
Run against UM12947 by bridges/mm_client_check.py, read-only, over the USB-B
CDC-ACM port and over the RX55 to TCP :9034.

THE WIRE BYTES ARE IDENTICAL ON BOTH PATHS -- 11,580 B in and 761 B out, to
the byte, with matching identity, state and a 24-entry setup walk.  The
protocol does not care which physical layer it runs over, which is the thing
the modem path needed to prove.

Three findings, one of them a correction to my own prediction:

1. THE MODEM NEEDS FEWER READS, NOT MORE.  36 against USB's 83.  The tool's
   banner claimed the opposite.  The modem coalesces -- it buffers ~1 s then
   forwards one large TCP segment, where CDC-ACM delivers many small chunks.
   That is reassuring rather than alarming: the risk was a frame arriving
   split across reads, and the modem splits LESS than USB does.  Banner fixed
   to state the measured numbers instead of a guess.

2. ~0.65 s PER ROUND TRIP over cellular, independent of payload size.  A
   1,024 B chunk and a 16 B state read cost the same.  list_setups() takes
   16.05 s over the modem against 0.46 s over USB, for 24 commands.

   This is the number that matters for SFM's design: over cellular, minimise
   round trips, not bytes.  Enumerating setups costs 16 s -- cache it, never
   refresh it on a timer.  A 13 KB event is 14 chunks ~ 8.4 s of latency
   against ~0.03 s of data, which makes the unconfirmed single-request 0x5A
   streaming mode worth its two-minute bench test on its own.

3. THERE IS A RECORD-TYPE FIELD: 0x0C content[11], 0x07 waveform, 0x08
   histogram.  The reference says no type field is known and that the type
   must be carried out of the chain walk.  Found by diffing the six bench
   events' 0x0C records against their known types -- exactly one byte
   separates the groups and is constant within each -- then confirmed by
   predicting the right suffix for 6 of 6 on a blind re-run.

   Six events split 4/2 is thin evidence for a byte that could be a counter or
   a channel count, so it is recorded as a strong candidate, not settled, and
   mm_client_check keeps a fallback: it tries the other suffix on failure and
   says when the guess was wrong.

   Also flagged: the reference's claim that the type comes from SUB 0x0A's
   length is not visible in the download capture, where 0x0A is a standalone
   monitor-log walk after the last chain entry, not a per-event probe.

END TO END: all six bench events assembled by read_event_file() from captured
0x5A responses decode with the existing codec -- 4 waveforms at 12,288 /
12,288 / 12,288 / 8,192 samples and 2 histograms.  No new codec work needed;
/db/import/idf_file ingests a directly downloaded event unchanged.

Not covered: 11.0BD (still pure inference), a monitoring unit, a nearly-full
buffer, and the inbound call-home session.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-29 14:13:36 -04:00
serversdownandClaude Opus 5 f7d9a1d9cb tooling(micromate): drop the pyserial dependency from mm_client_check
Hit on the bench: mint-mac has no pyserial, and `pip install pyserial` is
refused outright by PEP 668 (externally-managed-environment) on Mint 22 /
Ubuntu 24.04 / Debian 12.  A field diagnostic that needs a pip install on a
locked-down host is one you cannot run at the moment you need it -- which is
exactly when this tool is for.

Replaced minimateplus.SerialTransport with a ~30-line stdlib `termios` port,
the same approach bridges/mm_link.py and scratch/fake_unit.py already take in
this repo.  Runs on a stock Python 3 anywhere.

Not a general SerialTransport replacement: no flow control, no parity options,
Linux/macOS only.  Enough for a Micromate, which is 8N1 with no handshaking.

Verified end to end against a fake unit on a pty, dribbling responses in
64-byte pieces: 194 reads for 10,958 B, identity/state/setup-walk all correct,
and a 4,076 B event downloaded across 4 chunks at the exact expected length.

Also clarified --baud in the help: it applies to the USB-A/FTDI path, and is
ignored by the USB-B "PC" port, which is CDC-ACM and negotiates its own rate.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-29 14:06:55 -04:00
serversdownandClaude Opus 5 c7ffdab570 tooling(micromate): mm_client_check -- exercise the read client on real hardware
Read-only: POLL, SERIAL, state, monitor status, the setup walk, and optionally
one event download.  Never writes, erases, or changes monitoring state.

Exists because everything in micromate/{framing,protocol,client}.py is
verified against captures taken over USB on one firmware line (11.0CB).  Two
things that cannot be verified that way:

- The modem path.  An RX55/RV55 buffers up to ~1 s before forwarding, so one
  logical response arrives as many small reads.  The client reads to frame
  completion rather than using read_until_idle's idle-gap detection, which
  should be strictly more robust for this -- but that needed proving.
- The 11.0BD firmware line, which reports flags=0x03, a shorter model string,
  and a 0x1C block 4 bytes longer.  All inference from one 2026-09-23 sweep
  whose captures never landed in the repo.  The tool says so loudly when it
  meets one, and flags an impossible battery voltage as the signature of the
  from-the-end offset bug.

Run it over both paths and diff; anything differing beyond timings is a
finding.  It counts reads and bytes per transport, because a higher read count
for the same bytes IS the buffering, made visible.

Smoke-tested against a scripted TCP unit replaying captured response bytes in
37-byte dribbles: 289 reads to carry 10,958 B, every frame reassembled, a
4,076 B event downloaded across 4 chunks with the assembled length exact.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-28 20:30:11 -04:00
serversdownandClaude Opus 5 f09b7dcaaf feat(micromate): client layer -- connect, state, setups; read-only
Step 3 of docs/micromate_client_spec.md: micromate/client.py, two models in
micromate/models.py, 26 offline tests.  Every response constant in the tests
is a real captured data section from UM12947.

Field offsets were measured rather than taken from the spec, which turned up
one general rule and one trap:

THE RESPONSE SHAPE.  Every response carries an 11-byte prefix and content
starts at data[11].  One rule, every command.

THE TRAP: data[0] is the content length & 0xFF, with no high byte anywhere in
the prefix.  It is therefore correct for every response under 256 bytes --
most of them -- and then reports 44 for a 2,092-byte setup block, 30 for a
286-byte monitor-log record, and 0 for a 1,024-byte download chunk.  182 of
251 captured responses agree with a naive read; the 69 that disagree are
exactly the ones >= 256 bytes.

That is the third length in this protocol read too narrow, after
payload[9]-vs-payload[8:10] in the probe response.  The client takes content
as data[11:] and lets the frame's own length bound it -- nothing needs the
declared length, since the frame already knows how long it is.

Also measured:

- POLL content[3] is 0x50, printable as "P", immediately before "Instantel".
  A generic printable-run scan therefore returns "PInstantel" -- it caught a
  test, not a unit.  Vendor comes from a fixed offset; the model is found by
  searching for "MM/", which is structural rather than positional and so
  survives the Thor line's shorter "MM/ISEE/S".
- The setup walk terminates on an EMPTY NAME, not an error: 23 responses, 22
  names, factory.MMB first through TEST1.mmb last.
- The 0x1C clock has an unidentified byte at content[6]; the hour is at
  content[7].  The protocol reference's 0x1C section already had this right
  and names the byte -- its one-line summary in the divergences list reads as
  six contiguous fields and is the version not to trust.  Re-verified against
  three captures: 19:12:25, 19:13:34 and 01:14:05 against filenames stamped
  19:12:14, 19:12:14 and 01:14:03.
- Battery and memory are read FORWARD from content start, never backward from
  the end.  This block is 4 bytes longer on the Thor line; the Series III
  from-the-end offsets give a 11.0BD unit 577.92 V.  A test appends the four
  trailing bytes and asserts the forward offsets survive.

connect() is narrower than the spec asked.  The spec said to mirror Thor's
POLL -> SERIAL -> 0x49 -> POLL "because it is known-good"; measurement showed
that is Thor's connection check (3 of 8 sessions) and its fourth frame repeats
its first.  So connect() sends the three reads that gather something, and
0x01 is not read at all -- Thor never reads it, its layout is unmapped, and
firmware_line comes free from any response's flags byte.  If a unit ever
refuses the next command after a cold connect, put the fourth POLL back and
record it.

A dead clock battery yields device_time=None rather than failing the whole
state read; an unreadable active setup yields active_setup=None rather than
failing connect.  Both are real device states.

Still verified only against 11.0CB and only over USB.  The BD offsets follow
from the extra bytes being trailing, which is documented but not something
this code has seen.

Full suite unchanged at 16 pre-existing failures; 445 passed, up 26.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-28 20:25:40 -04:00
serversdownandClaude Opus 5 a7e3a8f20a feat(micromate): protocol layer -- reads only, verified against Thor's frames
Step 2 of docs/micromate_client_spec.md: micromate/protocol.py plus 35
offline tests.  Reads only; nothing here writes, erases or changes
monitoring state.

The tests replay Thor's captured responses through a scripted transport and
assert the bytes we emit are the bytes Thor emits -- including a full replay
of the six-event download session, all 56 0x5A frames byte-for-byte.  A
passing test therefore means a real unit has already answered exactly that
frame.

Measuring the spec's command table against the captures found three more
errors in it, on top of the three the framing work found:

1. SUB 0x0A is the MONITOR-LOG WALK, not a keyed "event header, 30 B list
   record" read.  The same request repeated returns successive 297-byte
   records -- serial, mode, thresholds -- until an 11-byte ack ends the
   list.  The device holds the cursor; nothing in the request selects a
   record, and all nine captured frames carry identical params.

   Structural divergence worth noting: Series III reaches the same data via
   a record-type discriminator on its event chain, so partials and events
   share one walk.  Here the monitor log has its own cursor and the event
   chain never sees it.

2. 0x1E/0x1F carry token 0xFE at params[7].  The protocol reference
   documents all-zero params -- that was our own browse probing, which also
   worked.  Thor sends 0xFE on browse and download alike.

3. SUB 0x01 (device info) is never read by Thor in any captured session.
   Its 0xFFFF offset comes from our own probes, so it is the one read in
   the table with no Thor precedent.  Flagged in the docstring.

Two useful negatives, both from absence rather than presence:

- No SESSION_RESET (41 03).  Series III needs that 2-byte signal or a
  monitoring unit will not answer POLL over TCP.  Zero occurrences across
  all 8 sessions, including 40 frames exchanged with a unit that WAS
  monitoring.
- No universal preamble.  The only invariant is that a session opens with
  POLL; POLL -> SERIAL -> 0x49 -> POLL is Thor's connection check and
  appears in 3 of 8 sessions.  Setup pushes and scheduler reads open
  differently.

Two deliberate divergences from the Series III sibling:

- strict_checksums defaults True and RAISES.  minimateplus logs and
  continues because its parser cannot always tell an inner-frame delimiter
  from a checksum byte; that does not apply here, where the rule is exact
  on 251/251 frames.  The lenient default is instructive -- it hid a wrong
  checksum rule for two days.
- read_event_file() raises ShortRead rather than returning a truncated
  event.  The expected length is known up front, so the check is free, and
  a silently short event is the failure mode this codebase keeps hitting.

Every exchange resets the parser before sending, so a leftover frame is
discarded rather than answered with -- expected_sub catches a mismatched
SUB, but a same-SUB leftover would sail through with data for the wrong key.

File transfer (0x94/0x48) is deliberately out of scope: it needs a
data-carrying request frame, which is the frame type writes use, and that
boundary is worth keeping crisp in a read-only pass.

Full suite unchanged at 16 pre-existing failures (missing gitignored
fixtures); 419 passed, up 35.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-28 19:58:22 -04:00
serversdownandClaude Opus 5 5fe99568a2 feat(micromate): framing layer -- and three spec rules the bytes refuted
Step 1 of docs/micromate_client_spec.md: micromate/framing.py plus 31
offline tests.  Every rule was checked against the captures BEFORE being
written, which is the only reason this commit is not a bug.

Three things the spec asserted are wrong, all of which fail silently:

1. Requests are NOT plain Series III frames.  A Micromate escapes four
   byte values -- 0x02 0x03 0x04 0x10 -- where Series III escapes one.
   minimateplus.build_bw_frame reproduces 161 of Thor's 218 captured read
   frames; build_request() reproduces 218/218.  The 57 it missed include
   EVERY 0x5A download (offset 0x0400 puts a literal 0x04 in offset_hi)
   and the scheduler enable.  An unescaped 0x03/0x04 terminates the frame,
   so the unit never answers -- indistinguishable from a dead unit, and
   event download would have hit it on the first request ever sent.

2. The checksum is plain SUM8 of the destuffed payload, not the DLE-aware
   variant.  251/251 both directions.  The DLE-aware form is correct
   paired with Series III destuffing, which leaves an escaped byte as two
   bytes; after uniform destuffing it subtracts the correction twice and
   disagrees with the wire on 55 of 251 responses.

   scratch/mm_frame_parse.py shipped with exactly that pairing and looked
   clean only because it accepts either rule -- so it labelled those 55
   "SUM8" and never flagged one bad.  "Zero bad checksums" was true and
   carried no information.  A tool that tries N candidate rules cannot
   falsify any of them.  Fixed to validate against SUM8 alone.

3. SUB 0x5A is a 1024-byte chunk loop, not one request per event.  Thor's
   form, verified on all six bench events (4,076 -> 13,424 B): chunks =
   ceil(size/1024), offset = min(1024, size - 1024*i) as a byte count,
   params[2:4] = the byte offset, response data = offset + 11.
   sum(offsets) == size exactly, every time.

   This does not retract the earlier single-request observation -- that
   used offset_hi = 0x10, which in Series III is the bulk-stream marker,
   so it is plausibly a distinct streaming mode returning several frames.
   Those captures never landed in the repo, so it cannot be re-derived.
   Implement Thor's form; the other is worth one bench test.

Also: a 0x10 inside request params needs no special handling (settled --
Thor sends it, the wire doubles it), so the planned NotImplementedError
guard is gone.  declared_length -> probe_length, because it is only
meaningful in a probe reply and Thor never probes.

Synthesised test frames are marked and each says what it stands in for.
The flags=0x03 case is the only coverage of the Thor firmware line -- it
wants a real 11.0BD capture next time UM20147 is on a bench.

No writes.  Read-path framing only; nothing here can originate a command.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-27 05:24:24 -04:00
serversdownandClaude Opus 5 a7631a8179 docs(series4): RESOLVED -- FTDI cable AND a cold boot; modems bridge one session
The cable swap alone did not fix it.  A probe immediately after fitting a genuine
FTDI cable (lsusb 0403:6001, FT232) returned the same "connected, no reply".

A COLD BOOT of the unit was also required -- power button held five seconds
through the two-stage battery-disconnect prompt, powered back up with the cable
already attached.  THOR connected the moment it finished booting, and an
independent probe returned UM12947, idle, over cellular.

So the Micromate's USB host does not rescan on hot-swap: it enumerates that port
at boot and, having once failed to identify a device, does not try again.
Changing the cable is a power-cycle operation -- and anyone swapping one in the
field who probes immediately will conclude the new cable is faulty too.  Full
chain: an FTDI or CDC-ACM cable, AND a cold boot with it attached.

SEPARATELY CONFIRMED, by accident: these modems bridge ONE TCP session to serial
at a time.  With THOR connected, the probe got "TCP ok, NO REPLY"; with THOR
disconnected and nothing else changed, the same probe returned the serial number.
The PAD accepts a second connection and then never forwards it -- it does not
refuse and does not close.

That makes "connected but no reply" ambiguous between a broken serial path and
somebody else already holding the unit, and mm_probe reported only the former --
which would push a diagnosis in exactly the wrong direction, on the very fault we
spent two days chasing.  Its verdict now names both causes, tells you to
eliminate contention first, and includes the cable-chipset and cold-boot steps.

Recorded as an SFM design constraint: our receiver and THOR cannot both hold a
unit, and during any migration both will exist.  "Another client holds this unit"
has to be a distinct visible state.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-26 18:11:16 -04:00
serversdownandClaude Opus 5 8a1d1c3f17 docs(series4): spec the live client, so tomorrow is implementation not design
Turns docs/micromate_protocol_reference.md into a build plan for the missing half
of micromate/ -- it is codec-only today with no way to talk to a unit.

Layout mirrors minimateplus/: framing, protocol, client.  Transport is REUSED --
minimateplus/transport.py is byte-level and protocol-agnostic, and already
handles the RV50/RV55 habit of emitting RING/CONNECT to a caller.  But
minimateplus/framing is deliberately NOT shared: the two framings differ in ways
that look small and are not, and a shared module would accumulate `if series ==`
branches until neither case is readable.

Records the three things that make S3FrameParser useless on Series IV (bare STX,
0xC5/0x03 flags, uniform 10 XX -> XX destuffing with no inner-frame carve-out),
and the traps that have already cost time: the declared length is a uint16 BE and
reading it as a byte under-reads SUB 0x1A by 47x; SUB 0x1C is four bytes longer
on the Thor line so parse forward not backward, or a BD unit reports 577.92 V;
the monitoring flag must be tested non-zero; and the SUB byte itself can arrive
DLE-escaped, so destuff before indexing.

Scope is READ-ONLY, stated with the reasoning: no command has ever been
originated against a unit by this project, and keeping that true through the read
client means the first thing we ever send to a customer's instrument is a
deliberate decision rather than a side effect of a client that grew a method.

Tests are specified to embed frames as hex constants rather than read fixtures,
since bridges/captures/ and tests/fixtures/ are both gitignored -- with a table
of which cases matter and why, and a round-trip assertion against
scratch/mm_frame_parse.py, which is already known good across three sessions at
zero bad checksums.

Steps 1-2 need no hardware.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-26 01:59:35 -04:00
serversdownandClaude Opus 5 27b0b25f15 docs(claude): refresh "Where things stand" -- Series-4 live protocol and tooling
The orientation block was dated 2026-08-28 and predated every finding from the
Series-4 live-protocol work, which is exactly the content a fresh session needs
and cannot discover on its own.

Adds, at the top where it will actually be read:

  * The Series-4 live wire protocol is mapped end to end, with the three framing
    differences that break a Series III parser (no leading DLE, 0xC5/0x03 flags,
    uint16 length at payload[8:10]) and the note that the inbound call-home
    session is the only protocol unknown left.
  * That NO command has ever been originated against a unit by this project --
    every write was performed by THOR while we recorded.  Worth stating plainly
    so the next session does not casually break it.
  * That micromate/ is still codec-only with no live client, and that
    minimateplus.transport is protocol-agnostic and reusable when one is built.
  * The bench tooling, including why mm_frame_parse.py has to exist at all:
    S3FrameParser scans for DLE+STX and therefore cannot see Micromate
    responses.
  * The FTDI/CDC-ACM-only USB host constraint and the Sabrent/Benfei cable trap,
    since a PL2303 cable leaves a unit with no working modem port and the cables
    are indistinguishable by eye.

Corrects a stale operational claim: the v0.30.0 Series-4 backfill HAS now been
run on prod, so the ~3.3%-low geophone values are fixed and the job does not need
repeating.

Also generalises the "update the protocol reference" instruction from the single
Series III document to a table of all three, and adds bridges/ plus the two newer
docs to the project layout.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-26 00:09:55 -04:00
serversdownandClaude Opus 5 5fa181fb79 docs(series4): confirmed -- the cable came home with the failed unit
Removes the last caveat.  The Benfei (Prolific PL2303) on the bench is physically
the cable from the failed office setup, not a substitute picked up later.

The chain has no inference left: that cable is a PL2303; the Micromate USB host
has no Prolific driver in either firmware line; a laptop on the same cable and
modem round-trips perfectly; the Micromate on it never answered.  The FTDI cable
arriving 2026-09-26 is now a confirmation rather than a test.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 23:27:39 -04:00
serversdownandClaude Opus 5 0659543a15 docs(series4): the 2026-09-22 failure is accounted for -- the timeline was wrong
An earlier draft said the Prolific-cable finding did not fit the timeline, since
the unit was described as working and then degrading, which a cable that never
enumerates cannot do.  The timeline was what needed correcting.

From the operator: the initial setup was ONE modem and ONE cable, and it worked.
Two Micromates then had to be deployed, so a second cable was fetched to run both
at once -- and only one of the two ever worked.  The other never talked over its
modem at any point, was never deployed, and a MiniMate Plus went out in its place.
That Micromate came back to the bench, and the cable on it is a Benfei (Prolific
PL2303).

So nothing degraded.  The "worked at first" was the single-cable setup before the
split.  One unit working and one not, configured side by side, is the signature of
a mixed cable supply rather than a unit fault.

Still worth confirming whether that cable travelled home with the unit or was
picked up at the bench; if it travelled with it there is no inference left.  The
FTDI cable arriving 2026-09-26 settles it either way -- same unit, same modem, one
variable.

Records a corollary: "just deploy a Series III instead" works partly because a
MiniMate Plus has a DB-9 port directly on the unit, with no USB-to-serial adapter
in the path and therefore no chipset to get wrong.  That workaround has been
routing around this exact failure mode.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 23:27:21 -04:00
serversdownandClaude Opus 5 922c304734 docs(changelog): Series-4 live protocol, THOR behaviour, and bench tooling
Written on dev as part of finishing the merge, per the repo convention, and
folded into the existing Unreleased sections rather than adding duplicates.

Added: the Micromate wire protocol (framing divergences, read path, event chain,
0x5A verbatim file streaming), setup management as read-modify-write with 0xDA
creating files, the decoded scheduler file, the path-addressed file transfer that
retracts an earlier "no such command" conclusion, monitoring control and
per-event delete, and four new tools -- mm_probe, mm_link, mm_frame_parse,
socat_log_split and fake_unit.

Changed: what THOR actually does on the wire (eleven-command status check, ~2.2 KB
a time, 18.8 MB/day/unit at 10 s), the connection interval setting a count rather
than a period, two reproduced THOR defects (silent poll death with a false
"Connected", and a subscription leak growing 1 -> 12 handlers over ten hours), and
the Micromate USB host supporting FTDI and CDC-ACM but not Prolific.

Migration extended to state the operational consequence for the whole section:
none.  No codec, store, DB or TOOL_VERSION change; the Series-4 work touches only
docs/, bridges/ and scratch/.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 22:41:55 -04:00
serversdownandClaude Opus 5 5f81fb0217 merge: Series-4 live protocol, THOR behaviour, and bench diagnostic tooling
Reverse-engineers the Micromate (Series IV) wire protocol end to end against a
bench unit and a recording relay, and characterises THOR's own behaviour on the
wire.  Purely additive -- 3,590 insertions, no deletions, no existing module
touched.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 22:40:19 -04:00
serversdownandClaude Opus 5 4a96e1a2b2 docs(series4): the bench cable was confirmed a Benfei (Prolific)
Closes the identification chain: firmware has no Prolific driver, a laptop
answers on that cable where the Micromate does not, lsusb reported PL2303,
purchasing history shows both FTDI and Prolific cables in circulation, and the
physical cable on the bench is a Benfei.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 20:55:18 -04:00
serversdownandClaude Opus 5 062d65ba69 docs(series4): purchasing history corroborates the cable finding
TMI's order history shows TWO kinds of USB-to-serial cable in circulation:

    Sabrent USB 2.0 to serial   FTDI chipset      -> Micromate has a driver
    Benfei  USB to RS-232       Prolific PL2303   -> no driver

So both types are in the supply and indistinguishable by eye.  A unit handed the
wrong one has no working modem port and nothing about the cable says so.  That
moves the PL2303 explanation from "a theory about one odd cable" to a known mix.

Adds the identification note: check chipset with lsusb, not appearance -- FTDI is
VID 0403, Prolific 067b -- and flags that counterfeit FTDI chips are common in
cheap cables, carrying FTDI's VID without behaving like one.  An embedded host
with a single driver is far less forgiving than Linux.

Also records honestly that this does NOT fit the 2026-09-22 field outage as
reported: a Prolific cable never enumerates, so it cannot fail gradually, and
that unit was described as working before degrading.  Notes the one story where
it would fit -- if the initial success was over the USB PC port or a bench test
before deployment, the modem path would have been broken from deployment onward
and the recollection would be conflating two connection types.  Plausible,
unverified, recorded as such.  Identifying that unit's cable settles it.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 20:54:56 -04:00
serversdownandClaude Opus 5 8a0134070b docs(series4): soften the cable finding -- well-supported, not proven
The operator pushed back on calling this solved, correctly.  Adjusting the wording
to match what the evidence actually carries.

What IS supported: on this bench setup, the modem and cable work bidirectionally
(laptop round trip, 700 ms), the same cable/modem pairing answers for a laptop and
not for the Micromate, and neither firmware image contains a Prolific driver.
Observation plus mechanism.

What is NOT: that this explains the field failures.  Those cables cannot be
inspected, and the timeline does not fit -- a wrong cable fails from the first
packet, and that unit reportedly worked before degrading.

A gap in the bench claim itself, now stated: "no driver" is inferred from ABSENCE
of strings.  usbHostDelete_* reads like a complete per-class list, which is good
evidence, but driver code can exist without a matching string and the USB
enumeration path has not been disassembled.

Names the test that removes the inference entirely: try an FTDI cable (VID 0403)
on the same modem.  Either it works or it does not.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 20:35:13 -04:00
serversdownandClaude Opus 5 84ca10eb3c docs(series4): the Micromate USB host is FTDI + CDC-ACM only -- not Prolific
A Micromate on an RX55 was unreachable from THOR.  Isolated layer by layer with
bridges/mm_probe.py, and the answer turned out to be the cable.

The USB-A port is a HOST port with a fixed driver set, identical in both firmware
lines:

    CDCACM  FTDI  MFS (mass storage)  PRINTER  HUB  HC  USBH

11 FTDISER strings and 22 CDCACM strings in each image, and ZERO matches for
prolific / pl2303 / cp210 / ch34 / silabs in either.  So a Prolific PL2303 cable
(VID 067b) cannot work with a Micromate on any firmware -- no driver, no
enumeration, no serial path.  It needs an FTDI cable (VID 0403) or CDC-ACM.

The isolation method is the part worth keeping.  Eliminated in turn: public IP
(static APN), firewall (probe got TCP connect in 268 ms from a whitelisted
source), network path, baud, the unit's modem-type setting, and THOR itself
(the probe bypasses it).  Then the decisive pair -- a Linux box was swapped in
for the unit on the SAME cable and modem:

  * POLL arrived at the serial side byte-perfect
  * a canned reply came back over TCP, full round trip in 700 ms

So the modem, PAD config, firewall and network are all clean, and the only
element that changed is what sits at the end of the cable.  Substituting a
known-good device converts "the unit is not answering" into "the unit is not
receiving" -- very different problems.  Adds scratch/fake_unit.py for that.

Flagged: this explains the BENCH setup conclusively.  It does NOT establish the
cause of the 2026-09-22 field outage, which reportedly worked at first and
degraded -- a wrong cable would not do that.  Kept separate until that unit's
cable is identified.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 17:48:36 -04:00
serversdownandClaude Opus 5 7b2aa871bd docs(series4): record a known-good RV55 config, and the office topology it reveals
Read off a Micromate modem deployed and working for months.  Recorded because
this knowledge currently lives only in a modem's web UI, and TMI has seven
working units to diff a misbehaving one against -- the fastest diagnostic
available.

Serial: PAD mode, 115200 8N1, flow control None.  (Series III units use 38400 --
a modem moved between series needs this changed and nobody would think to.)

PAD: TCP, auto-answer ON, listening port 9034, destination 50.197.32.91:12345,
idle timeout 2 min, data forwarding 500 ms, MTU 1304, TCP keepalive OFF.

Cellular: APN mw01.VZWSTATIC -- Verizon's static-IP APN, which confirms the fleet
has fixed addresses and rules out any "the IP moved" explanation.

TOPOLOGY this answers: the office ACH listener is on port 12345 at 50.197.32.91,
and field modems listen on 9034 for THOR to dial in.  Both were open questions.

Two things worth questioning in the config, flagged as hypothesis not finding:

  * TCP keepalive is Off, so nothing detects a half-open session from the modem
    side -- the 2-minute idle timeout is the only reaper.
  * An idle timer can be held open indefinitely by a client that keeps writing.
    THOR polls every 30 s (measured).  If it holds a session the unit stopped
    answering on and keeps writing into it, each write plausibly resets the idle
    timer, the session never ages out, the PAD's single slot stays occupied, and
    all new inbound fails -- while ACEmanager answers on its own service.
    Whether one-directional traffic resets that timer is NOT confirmed, and the
    single-slot behaviour is untested on a real modem.  mm_probe --slots tests
    the latter directly.

Adds an ordered diff checklist for a misbehaving modem, noting that "listen for
connections" and "destination address" fail in opposite directions -- inbound
broken with call-home working points at the listener; call-home broken with
inbound working points at the destination.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 15:01:46 -04:00
serversdownandClaude Opus 5 704cd7b111 feat(bridges): mm_probe -- tell apart the four faults THOR calls "disconnected"
THOR reports every failed connection as "disconnected" and nothing more.  That
one word covers at least four distinct faults with four different fixes, and
telling them apart is the difference between a modem reboot and a site visit.
Nobody had a way to do that during the 2026-09-22 outage, which is the actual gap
that incident exposed -- not a missing THOR feature, but a missing tool.

    connection refused    something answered and said no -- wrong port, or the
                          modem refusing a further session
    connect timed out     nothing answered -- trusted-IP whitelist, firewall, or
                          the modem is off the network.  A whitelist DISCARDS
                          rather than refuses, so this is its signature
    connected, no reply   the MODEM answered but the unit did not.  TCP is fine;
                          the modem is not forwarding to serial.  This is what a
                          wedged transparent-TCP session looks like, and it is
                          the case THOR cannot distinguish from the others
    replied               the unit is alive; the fault is upstream software

Each verdict prints what to try next.  The no-reply case points at ACEmanager's
TCP Idle Timeout first, since a stale session holds a single-slot modem's only
connection until that timeout frees it.

--slots N opens N simultaneous connections and reports how many the far end
accepts, which directly tests the single-session hypothesis against a real modem.

Read-only throughout: POLL, SERIAL and the 0x49 state read -- the same three
commands THOR's own connection check uses.  Sends the correct per-SUB data
offsets (POLL 0x0030, SERIAL 0x000A, 0x49 0xFFFF); offset 0 returns only the
short probe reply.

Works for both series and says which answered: a Series III reply opens DLE STX,
a Micromate reply opens with a bare STX.

Verified against UM12947 through the bench relay, and against a closed port for
the refused path.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 14:50:44 -04:00
serversdownandClaude Opus 5 a404d70791 docs(series4): THOR leaks event subscriptions -- evidence from its own log
The office THOR PC's log for 2026-09-22 contains a textbook WPF defect, visible
without any instrumentation.

85% of a day's logging is one message: "UnitOperatingModeViewModel - Start/stop
monitoring request timed out: False", 178 of 209 lines.  Only 12 lines describe
an actual operation.

Grouping that message by exact timestamp to the millisecond -- so each group is
ONE logical event -- the count per event grows over the day:

    11:48         1-4
    13:36-13:40   2-4
    15:16         3
    16:03-16:07   6
    22:00-22:06   12

1 -> 12 over ten hours of uptime.  Twelve identical lines sharing a single
millisecond is not twelve events; it is one event dispatched to twelve handlers.

That is a subscription leak, and the class name identifies it.  THOR is .NET/WPF
("App thread", ViewModel naming), where a view model subscribing on view-open and
never unsubscribing on view-close is the archetypal case.

Consequences that follow directly: N grows without bound with uptime and usage;
every notification does N times the work; and a restart resets N to 1 -- matching
the operator's report that only restarting recovers a degraded session.  The only
five "timed out: True" entries in the file sit at the very top, an episode caught
just before rotation.

Claim discipline stated explicitly in the doc.  ESTABLISHED: the handler count
grows.  STRONG INFERENCE: it is a subscription leak.  NOT ESTABLISHED: that it
caused the 2026-09-22 field outage -- this log does not cover that window and the
link between leaked handlers and a dead TCP path is unproven.

Includes a ten-minute confirmation procedure: restart THOR, note the burst size,
open and close a unit detail view ten times, re-count.

Three lessons for SFM: unsubscribe on teardown or use weak events; log once per
event rather than once per handler; and log what CHANGED -- 178 "timed out:
False" lines are noise that buried the five that mattered, which is plausibly why
this went unnoticed.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 14:13:36 -04:00
serversdownandClaude Opus 5 992b84df51 docs(series4): modem settings live in SysParm.cfg, not the setup -- deliberately
Settled by a clean experiment.  The call-modem setting was changed on the keypad
from 'generic' to 'USB to PC', then the ACTIVE SETUP was switched from TEST1 to
test2 on the device.  The setting did not change.  So it is device-global, in the
SysParm.cfg the firmware strings already hinted at alongside
SysPref.bMonitorScheduler -- not a per-setup field.

That closes a hypothesis this document was chasing: the ~102 bytes a .MMB file
carries beyond the 2,090-byte config block are NOT where this lives.  Those bytes
remain unexplained but are no longer a candidate.

CORRECTS an over-reading in an earlier commit.  "The call-home block (0x2C) was
byte-identical across 218 samples today" does not bear on this question: the last
0x2C sample was at 13:30:23 and the keypad change came around 13:35, so no sample
exists on the far side of it.

Why the split is right, and the operator's reading of it: you do not want modem
settings reachable remotely, because getting them wrong over the air destroys the
connection you would need to put them back, and the unit must then be visited.
So SUB 0x2C is not an incomplete view of the modem configuration -- it is the
deliberately-chosen subset that is SAFE to change remotely (enable, dial string,
retries, timings), and the unreachable remainder is unreachable on purpose.

Records the design principle for SFM: for settings whose misconfiguration
destroys the channel you would use to fix them, either do not expose them for
remote write, or require commit/confirm with automatic rollback (apply, require a
call-back within N minutes, revert otherwise).  Always allow READING them, so an
operator can diagnose a unit they cannot reconfigure.  Instantel chose the first
option and given the failure mode that is worth copying rather than improving on.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 13:47:42 -04:00
serversdownandClaude Opus 5 8b6c89da42 docs(series4): a live monitoring unit displayed as Idle -- and a flag I got wrong
The operator's test: start monitoring from the unit's keypad and see whether THOR
notices.  It does not.

At 13:21:15, verified by an independent probe through the same relay:

    unit on the wire    0x49 data[11]=0x02, 0x1C data[12]=0x0c  -> MONITORING
    THOR last contact   13:10:37 (a stop-monitoring command it issued itself)
    THOR display        Connected . Monitoring Mode: Idle . Last Updated 1:04:22

A unit is actively recording and THOR shows it as Idle.  Had an event triggered
in that window THOR would not have known and would not have collected it.  That
is the operational consequence of the wedge -- not a wrong indicator, but a
monitoring system that has silently stopped monitoring its monitor.

Further detail: THOR DID contact the unit at 13:10:37 and read MONITOR_STATUS,
yet Last Updated still reads 1:04:22.  A successful exchange does not refresh
that timestamp; only the full status check does.  The one honest field on the
screen is honest about the wrong thing, which makes it useless as a staleness
indicator exactly when staleness is the problem.

CORRECTS a documented constant.  SUB 0x1C data[12] was recorded as "0x0E
monitoring / 0x00 idle".  It read 0x0E on 2026-09-24 and 0x0C on 2026-09-25, both
while monitoring, so it carries sub-state in its low bits and is not a flag.  Test
for NON-ZERO, never against a constant -- an implementation comparing to 0x0E
would have reported this unit idle.  Same caution noted for 0x49 data[11], which
has only ever been seen as 0x02.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 13:21:49 -04:00
serversdownandClaude Opus 5 d93ebe2322 docs(series4): correct a sloppy count -- the conclusion holds, the evidence did not
The claim "THOR connections since 13:04:22 : 0" was an artifact of a time filter
(13:0[4-9]) that silently dropped everything from 13:10 onward.  THOR had in fact
connected four times, at 13:10:03-13:10:37.  Recorded rather than quietly fixed:
the number was stated as proven and it was wrong.

Inspecting those four connections shows the conclusion survives, for a better
reason than the one originally given.  They were user-initiated commands, not
polling:

    13:10:03  POLL -> SUB_96 (start monitoring)   13:10:05  MONITOR_STATUS
    13:10:35  POLL -> SUB_97 (stop monitoring)    13:10:37  MONITOR_STATUS

Single commands a human clicked, each followed by one status read.  Neither the
eleven-command status check nor the three-command connection check appears
anywhere in the window.

So automatic polling still has not resumed since 13:03:10 -- 16 minutes by
13:19:53 -- and every THOR connection in that window was operator-initiated:
the refresh at 13:04:21, then start and stop monitoring at 13:10.

Updates finding 3 from "three minutes of healthy link produced zero connection
attempts" to the stronger and now properly-evidenced "sixteen minutes produced no
AUTOMATIC attempts at all, only ones initiated by hand".

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 13:20:52 -04:00
serversdownandClaude Opus 5 cfc715c02f docs(series4): THOR shows "Connected" for 11 minutes after it stopped checking
Closes the question the last two commits left open -- what the UI actually shows
during the dead window.  It is the bad case.

Captured at 13:15, eleven minutes after THOR's last contact with the unit:

    Connection Status : Connected                  <- false
    Last Updated      : 09/25/2026 01:04:22 PM     <- true, and that is the REFRESH
    Notification      : "Unable to download event(s) ... Did not receive
                         response from unit."  (01:03:31 PM)

Three separable points:

  * The green tile is false -- it reports a live connection not exercised for
    eleven minutes.
  * Last Updated is TRUE, and is the only honest field on the screen.  THOR knows
    when it last succeeded; it renders that as small grey text under the unit
    name, unhighlighted and unmarked as stale, beneath a large green Connected
    tile.  The operator must read a timestamp and do arithmetic to find out the
    headline is wrong.
  * The failure THOR did report was the DOWNLOAD, not the poller stopping.  The
    two are treated as unrelated; nothing states that automatic checking ceased.

So the state is not merely undisplayed: THOR holds the data that would reveal it
and presents a contradicting summary instead.

Adds design consequence 0, ahead of the others because it is the highest-value
fix and the cheapest: connection status must EXPIRE.  If the last successful
check is older than a small multiple of the interval, the state is stale/unknown,
never Connected.  THOR already has the timestamp; it just does not let it
invalidate the summary.

Same screen independently corroborates four of our decodes: memory 14.94/15.00 MB
against the exact 15,000,000-byte total from SUB 0x1C; Unit Date/Time 01:04:20 PM
against the device clock at 0x1C data[13:21]; Scheduler Enabled against 0x47; and
Auto Call Home Disabled against the write[5]=0x04 observed in the 0x7E capture.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 13:15:39 -04:00
serversdownandClaude Opus 5 eccd28ea0d docs(series4): "not polling" and "unreachable" are different states
Follow-up to the reproduced wedge, and the sharpest point to come out of it --
the operator's observation, demonstrated directly.

At 13:10:44, six and a half minutes after THOR's last connection of any kind:

    THOR connections since 13:04:22 : 0
    independent POLL through the same relay, same moment : succeeds

The unit is reachable.  The link is fine.  THOR is simply not asking.

So whatever THOR's UI reports in that window is wrong.  "Connected/OK" is false
because nothing has been checked for minutes.  "Disconnected/unreachable" is also
false because the unit answers on demand.  The true state -- "I have given up
checking this unit" -- is not one THOR can display.

An operator therefore cannot separate "the unit is down" from "the poller is
asleep", and those demand completely different responses: a site visit versus a
mouse click.

This settles a question the previous commit left open.  It does not matter much
whether stopping after one retry is intentional or a defect: the reporting is
wrong either way, since both plausible displays misrepresent reality.

Sharpens design consequence 4 accordingly -- a unit's displayed state should be
one of: checks passing, checks failing (with attempt count and last error), or
not being checked (with why, and a way to resume).  Collapsing the last two into
a single indicator is the root of this failure being undiagnosable.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 13:11:18 -04:00
serversdownandClaude Opus 5 04b1ef3e04 docs(series4): REPRODUCED -- THOR stops polling after a drop mid-download
The field failure on UM12947 ("wouldn't stay connected, refresh did nothing, no
way to view a connection attempt") reproduced on the bench, with timestamps.

THOR was mid-bulk-download when the link was faulted.  Sequence:

    13:02:50  connection dies mid-transfer (165 BULK_DOWNLOAD frames in)
    13:03:10  THOR reconnects once after 20 s, sends SUB_1F to resume, fails
    13:03:33  link fully restored and healthy
    13:04:21  operator clicks Refresh -> full 11-command check, all correct
    13:06:27  still nothing.  That refresh is the ONLY connection since 13:03:10.

Before the fault THOR had connected every 30 s without a miss for over an hour.

Establishes four things:
  * one retry then give up -- no backoff, no further attempts
  * the automatic poll loop dies too, not just the download
  * it does not recover when the link returns (3 min of healthy link, nothing)
  * Refresh works but only once -- it does NOT restart the automatic loop

The fourth is the dangerous one: Refresh makes the UI report a healthy unit while
nothing is watching it.  Silent failure that looks like success.  It also explains
why the field symptom resists characterisation -- the unit is reachable the whole
time; THOR has simply stopped asking and says nothing about it.

CAVEAT, recorded prominently: what THOR experienced was a TCP close mid-download,
not the silent link intended.  mm_link.py mistook socket.timeout (which subclasses
OSError) for a closed socket, so 200 ms of quiet closed the connection -- the
relay killed the link it was meant to be faking a fault on.  Fixed in this commit.
The run stands as a drop-mid-download test, arguably the more realistic case.
Single trial; true blackhole and clean drop not yet tested.

Adds four design consequences for SFM: unbounded retry with backoff; a manual
check must restart the automatic loop or the UI must say it is stopped; surface
the poll loop's own state (last success, last attempt, next attempt, consecutive
failures -- all four invisible here); and distinguish "unit unreachable" from "we
stopped checking", which present identically in THOR.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 13:07:12 -04:00
serversdownandClaude Opus 5 f1215ef9d9 docs(series4): REFUTE the half-period theory -- the connection dial sets a count
The prediction was sharp and it was wrong.  I hypothesised the connection check
ran at half the status period, predicting 30 s when status is set to 60 s.
Measured: 60.5 s.  Recorded rather than quietly deleted.

Three configurations now measured, each over many cycles:

    status 10 / conn 10  ->  status 10.1 s    conn: none ever ran      0 per cycle
    status 30 / conn 10  ->  status 30.4 s    conn 15.2 s              2 per cycle
    status 60 / conn 30  ->  status 60.5 s    conn 60.5 s              1 per cycle

The status dial is honoured in all three, within ~1%.  The connection dial is
honoured in none.  What holds across all three is a count, not a period:

    separate connection checks per status cycle = (status / connection) - 1

Consequences: setting the two dials equal yields ZERO connection checks, so every
connection is the expensive eleven-command status read -- and that is the
configuration that looks like the default.  "Every 30 s" with status at 60 s
gives one check per minute, half the advertised rate.  No simple scale factor
describes the observed cadences either (10 -> 15.2, 30 -> 60.5).

Still unexplained: the phase within a cycle.  At status 30 / conn 10 the two short
checks landed at T+10.1 and T+25.3 where an evenly divided cycle would put them at
T+10 and T+20.  The count rule holds; the phase does not follow from it.

Also adds a traffic table across the three configurations: 563 MB/month at
10 s/10 s, 147 MB/month at the current 60 s/30 s, against 9 MB/month for a
POLL + MONITOR_STATUS check at 60 s.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 12:50:36 -04:00
serversdownandClaude Opus 5 61e8a5e220 docs(series4): two poll checks, and only the status dial is honoured
Corrects the previous commit.  It claimed both intervals were set to 5 s, taken
from a screenshot that turned out to predate the operator's change -- they were at
10 s.  The "setting + 5 s" pattern I inferred from that does not survive, and is
removed.

What a longer capture with asymmetric intervals (connection 10 s, status 30 s)
actually shows:

There are TWO distinct checks, not one.  The eleven-command sequence is the
status check; there is also a three-command connection check, POLL -> SERIAL ->
0x49.

With both dials EQUAL the connection check never runs separately at all -- every
connection observed was the full eleven commands.  It only appears once the
intervals differ.  That alone explains much of "changing the settings does
nothing": at equal values you only ever get the expensive one.

Steady state over 14 consecutive cycles:

    FULL  at T          short at T+10.1
    short at T+25.3     FULL  at T+30.4

    status check      set 30 s -> observed 30.4 s   honoured
    connection check  set 10 s -> observed 15.2 s   52% slow

27 consecutive connection-check gaps, all 15.1-15.3 s.  Systematic, not jitter.

15.2 s is exactly half of 30.4 s and the two are phase-locked 2:1, suggesting the
connection check runs at half the STATUS period rather than on its own setting.
Flagged as a hypothesis with a sharp prediction: at status 60 s the connection
check should land at 30 s whatever its dial says.  Worth settling before SFM
offers a similar control -- a dial that silently does nothing is worse than no
dial.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 11:46:11 -04:00
serversdownandClaude Opus 5 d522d31d63 docs(series4): what THOR's "status check" actually is -- 11 commands, 563 MB/month
First capture through bridges/mm_link.py, with THOR polling a unit over the bench
link at "check connection every 5 s / check status every 5 s".

A status check is ELEVEN commands, not one:

    POLL -> DEVICE_INFO -> 0x49 -> 0x5C -> MONITOR_STATUS -> SETUP_NAME_READ
         -> STORAGE_RANGE -> 0x02 -> OPERATOR -> 0x47 -> CALLHOME_CFG

Each check opens a NEW TCP connection, runs all eleven exchanges in ~300 ms and
closes it.  Measured over 21 consecutive checks: 236 B out, 936 B back, plus a
full handshake each time -- about 2.2 KB per check.

At the observed cadence that is 18.8 MB/day, 563 MB/month, per unit.  On a
metered cellular plan that is real money, and most of it is waste: the check
re-reads the call-home config, operator name, active setup name and full device
info every ten seconds, none of which changes.  SETUP_NAME_READ alone returns 274
bytes a time.  POLL + MONITOR_STATUS answers "alive?" and "monitoring?" in two
commands and 131 bytes.

Both intervals set to 5 s yields one combined pass every 10.1 s, steady across
eight measured connections.  So the two settings are not independent 5-second
timers, which is a plausible reason changing them appears to do nothing.

REVISES an earlier hypothesis.  Because idle polling reconnects every cycle, a
silently-dead link is LESS dangerous while idle than I assumed -- a dead socket
fails at connect and the next cycle retries.  The exposure is during OPERATIONS:
THOR held one connection from 00:30 to 00:47 last night while downloading events
and pushing setups.  A link dying mid-operation leaves it waiting on a socket the
OS will not fail for ~2 h.  The blackhole test should therefore be run during a
download, not while idle.

Also fixes a mislabel in mm_link.py: the SUB byte is DLE-escaped when its value is
0x02/0x03/0x04/0x10, so reading it raw reported SUB 0x02 as "SUB_10".

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 11:34:06 -04:00
serversdownandClaude Opus 5 45f2997a5b feat(bridges): mm_link -- a bench "modem" with a readable log and fault injection
THOR gives almost no visibility into a connection: a refresh button, two poll
intervals, and no way to see whether a check succeeded, timed out, or was never
attempted.  When a unit "won't stay connected" there is nothing to look at.  This
sits where the cellular modem would and answers that directly.

Over socat -x it adds the two things that were missing:

  * A READABLE LOG.  Frames are decoded and timestamped as they pass --
    "THOR->unit  POLL  (21 B)" rather than hex -- so THOR's polling cadence, and
    its silences, are visible.  Raw .bin pairs are still written alongside and
    load straight into scratch/mm_frame_parse.py.
  * FAULT INJECTION, via a control file read on the fly:
        pass       normal relay
        blackhole  TCP stays up, bytes are swallowed
        drop       close the connection abruptly
        delay:N    forward N seconds late, both directions
        onewaydev  THOR->unit passes, unit->THOR is swallowed

`blackhole` is the point of the exercise.  It reproduces the classic cellular
failure -- socket open at both ends, nothing crossing -- which a real cell link
will not do on cue.  THOR was observed last night holding one TCP connection for
17 minutes (00:30 to 00:47), so if the link dies silently the OS will not tell it
for roughly the default keepalive, ~2 hours.  That is a candidate explanation for
"refresh does nothing and only a restart helps", and this makes it testable
rather than speculative.

No pyserial: the port is driven through stdlib termios.  The bench hosts are
whatever is to hand and requiring a pip install on someone else's machine is a
poor trade for ~30 lines.  Deployed and verified on mint-mac (Python 3.12, no
third-party modules) against UM12947 -- a POLL round-trips and decodes.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 11:29:44 -04:00
serversdownandClaude Opus 5 96a8831472 docs(series4): pin down what the ACH config's volatile field is NOT
Followed up the write[118:120] field flagged in the previous commit.  A third
sample plus a brute-force sweep rules out most of the obvious explanations.

Samples: 43 23 at 00:50 (idle), still 43 23 at 01:16 twenty-six minutes later,
then 2e 5e after a config write.  Thor echoes back whatever it last read --
including a value that no longer matches the config it is sending -- and the
write is accepted regardless.

Ruled out:
  * a clock or timer  -- identical across 26 minutes of idle; only a write moved it
  * a counter         -- it decreased, 17187 -> 11870
  * computed by Thor  -- Thor demonstrably sends a stale value
  * a standard CRC16  -- swept all 65,536 polynomials x init {0x0000,0xFFFF} x all
                         four reflection combinations over four candidate regions.
                         No match.  Recorded so the sweep is not repeated.

It behaves like a unit-computed hash: a one-byte input change scattered the output
(XOR 0x6D7D) where a sum would move by 1.  But two samples cannot separate that
from a nonce regenerated per write.

Operationally it does not matter, which is the point: the unit does not validate
the field on input, so read-modify-write with the rest of the block echoed
verbatim is provably safe.  Never synthesise or zero it.

Notes what would resolve it -- several config writes with times recorded, cheap to
collect during any future ACH capture.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 01:56:21 -04:00
serversdownandClaude Opus 5 8e37803d40 docs(series4): event download, PER-EVENT delete, and the ACH config write
Three captures with operator ground truth (Thor screenshots of the event list and
the weekly schedule).  All Thor-originated.

DAY AND SCHEDULE TYPE, both settled by a weekly schedule.  Thor's screen showed
"Start Monitoring 8:00 AM every day, alternating TEST1/test2, Repeat Weekly
disabled".  The file is 7 x 260 + 4 = 1824 bytes and every record matches row for
row:

  Day = 0 Sunday .. 6 Saturday

and [0] on record 0 read 4, against 2 and 3 in the daily schedules, so it carries
schedule TYPE as well as Repeat:  2 daily, 3 daily+repeat, 4 weekly,
5 weekly+repeat (predicted, unobserved).  Bit 0 is Repeat; 2 and 4 are the bases.
Same bitmask style as [6].

In daily schedules Day reads 3 everywhere and is presumably ignored -- inference,
and the value 3 is unexplained.

EVENT DOWNLOAD.  SUB 0x93 -> 0x6C arms each event before 1E/1F, with empty params
and an all-zero ack -- the Series IV analogue of Series III's 1E(token=0xFE), and
simpler.  Event keys are a plain sequential counter (055D4A81..86 for six events)
at data[11:15], with the event size at data[17:19].  SUB 0x0A walks the list as
30-byte timestamped records; the dates match Thor's event list exactly.

DELETE IS PER-EVENT -- and this is the last piece a homebrew ACH receiver was
missing:

    0xA8  params[0:4] = <event key>  -> ack 0x57
    0xAA  params = zeros             -> ack 0x55

The operator deleted the top row of Thor's list (the newest event) and 0xA8
carried 055D4A86, the highest key from the walk.  Confirmed end to end.

Strictly safer than Series III, which can only erase everything: a receiver can
delete exactly what it has confirmed it stored.  Different opcodes -- do not reach
for 0xA3/0xA2.  Noted that SUB 0x06 read identically before and after, so it is
not a way to confirm a deletion landed.

ACH CONFIG.  0x2C / 0x7E / 0x7F with acks 0xD3 / 0x81 / 0x80 -- identical to
Series III.  126-byte write payload, offset 0x007E; the 0x2C read returns the same
bytes behind an 11-byte prefix.  The enable flag is write[5]: 0x05 enabled, 0x04
disabled.  Bit 0 is the flag, bit 2 set in both states -- do NOT test for
0x01/0x00 as Series III does.  Dial string at write[6:] ("RADIO RING").

Flagged: write[118:120] changed on its own between the two sessions (43 23 ->
2e 5e) with nothing touched, and Thor writes back whatever it read.  Round-trip
that field, never synthesise it.  Beyond the enable byte and dial string the field
map is NOT established -- only one setting was varied, and Series III's offsets
are a hypothesis, not a transfer.

Every command on the unsafe list is now observed.  None has been originated by
us, which is the line that still matters.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 01:26:42 -04:00
serversdownandClaude Opus 5 f839541d08 docs(series4): CORRECT the schedule record -- [6] is the Action bitmask, not [0]
A five-entry schedule (start/stop/self-check/start/ACH) overturns the two
previous readings of this record, and the operator supplied a Thor screenshot of
the schedule as ground truth.

[6] is the Action, and the values are powers of two:

    2 = Start Monitoring    4 = Stop Monitoring
    8 = Self Check         16 = Auto Call Home

Bits 1-4 of a bitmask; bit 0 (value 1) is unobserved -- a natural home for the
setup-less DUTYCYCLE_START_MONITOR, but that is a guess.

Two retractions:

  * [6] was recorded as "the one unidentified field" and predicted to be the
    Repeat flag.  It is the Action.
  * [0] was labelled Action, then "Action with repeat folded in".  Both wrong.
    [0] is non-zero only on record 0 -- records 0 and 3 here are the SAME action
    with different [0] values.  It is a schedule-level field carried in the first
    record, holding Repeat: 3 on, 2 off, matching "Repeat Daily: Disabled" on the
    Thor screen.

The earlier repeat capture was consistent with both readings because it had one
start entry and moved one byte.  A single-variable test is not always enough; it
took four distinct actions to separate the fields.

SUB 0x47 is confirmed as the scheduler enable.  Previously recorded as "genuinely
undetermined" whether it sets or reads -- Thor's notification pane timestamps it:
schedule write completes 00:51:29, "successfully SENT" 00:51:31, the 0x47 pair at
00:51:31 and 00:51:33, "successfully ENABLED" 00:51:35.  Nothing else sits between
the two notifications.  params[7] in {1,3} is still open and is more likely a
selector than a value, since a lone params[7]=3 also appears at session start.
It must be DLE-escaped -- a bare 0x03 truncates the frame.

SECOND RETRACTION: setups ARE written as raw .MMB files.  This document twice
said they are not.  Thor used both paths in one session, choosing by whether the
setup is active:

    TEST1.mmb (active)     0xDA -> 0x68/0x73 -> 0x82/0x83 -> 0x71/0x72
    test2.mmb (not active) 0x8D \system\setups\test2.mmb -> 0x8E (2192 B)

The .MMB file is nearly the compliance block -- 1968/2086 bytes equal (94.3%) at
a 4-byte shift, 102 bytes longer, name at offset 38 vs 42.  Same structure,
different framing.  Writing a setup as a file is the cleaner path for SFM: two
frames, no 0xDA/0x68/0x82 ritual, and it does not disturb the active setup.

Also: file writes are chunked.  The schedule's 1,304 bytes went as 1,024 + 280
with each offset = that chunk's length, but the 2,192-byte setup went in one
frame, so 1,024 is not a hard ceiling.  Rule unexplained, recorded as observed.

Capture provenance: the seismo_lab bins were empty (capture not stopped), and the
session was recovered from the socat relay log again -- 38 frames each way, 0 bad
checksums.  That fallback has now saved two captures.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 00:55:54 -04:00
serversdownandClaude Opus 5 cc1388df65 feat(scratch): recover captures from the socat relay log -- validated byte-exact
The bench relay runs socat with -x, which hex-dumps every forwarded byte in both
directions.  That makes its log a complete second copy of every capture taken
through it, independent of whether seismo_lab was recording.

On 2026-09-25 a capture's .bin files never left the Windows machine and the
session was rebuilt from the relay log instead.  When the real bins turned up
afterwards, the reconstruction was byte-for-byte IDENTICAL in both directions
(3,595 and 4,004 bytes) -- verified again through the committed script, not just
the ad-hoc version used at the time.  So this is a validated fallback, not a lossy
approximation.

Adds scratch/socat_log_split.py, with --from-line/--to-line for picking one
session out of a log that spans several (split on the "accepting connection"
markers, or the frame walk runs sessions together).

Also documents the -x flag and the fallback in the session-provenance section, so
the next person runs the relay in a way that keeps the safety net.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 00:37:10 -04:00
serversdownandClaude Opus 5 98cbdad489 docs(series4): Repeat is folded into Action -- and [6] is not the repeat flag
A capture that changed ONLY the Repeat Daily checkbox (pull schedule, disable
repeat, push schedule) moved exactly one byte in the entire session:

    record @0   Action  0x03 -> 0x02

Record 2 unchanged, [6] unchanged, and 0xDA / 0x68 / 0x82 / 0x71 / 0x94 / 0x8D all
byte-identical.

Two corrections to the previous commit:

  * [6] is NOT the repeat flag.  That was the field I predicted this capture would
    isolate; it stayed 2 and 16.  Still unidentified.
  * The label "Action" on [0] was too simple -- it carries repeat behaviour too.

Leading hypothesis: 2 and 3 are the two setup-bearing start actions the firmware
names, with repeat selecting between them --
    0 = DUTYCYCLE_CALLHOME
    2 = DUTYCYCLE_START_MONITOR_WITH_SETUP                 (repeat off)
    3 = DUTYCYCLE_START_MONITOR_WITH_SETUP_STOP_COMPLETE   (repeat on)

Supported independently by the THOR manual, which says a repeating schedule
hitting a Start Monitoring event while already monitoring will "stop the current
monitoring session, run any Auto Call Home actions, load the compliance setup and
continue monitoring" -- exactly what _STOP_COMPLETE should mean.  A repeating
start must terminate the in-progress session; a one-shot start need not.  The
firmware name, the manual's behaviour and the single moved byte all agree.

Explicitly NOT claiming the enum ordering: the action names were recovered with
`strings | sort`, so source order is lost.  Do not infer 1 = START_MONITOR just
because it falls between the two known values.  Three of six codes observed.

Also noted: Thor re-pushed the whole 2,090-byte config for a one-byte schedule
change -- a third instance of the schedule<->config coupling.

Capture provenance: the seismo_lab bins did not reach the dev box, but the socat
relay on mint-mac keeps its own timestamped -x log, and the session was
reconstructed from it byte-for-byte (25 frames each way, 0 bad checksums).  That
backup log is worth keeping in the loop -- it has now saved a capture once.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-25 00:35:09 -04:00
serversdownandClaude Opus 5 4a1cccf3f5 docs(series4): the schedule file is DECODED -- two records, five confirmations
The operator supplied the ground truth: entry 1 is "start monitoring TEST1" at
07:30, entry 2 is "Auto Call Home" at 19:30.  That decodes the file completely.

The body is two 260-byte records plus four zero bytes = 524 exactly, and every
non-zero byte falls inside them:

  [0]     Action       (0 = Auto Call Home, 3 = start monitoring with setup)
  [1:4]   padding
  [4]     1/2h         half-hour slot, 0-47
  [5]     Day
  [6]     ??           the one unidentified field
  [7]     name length
  [8:260] setup name, null-padded

  record @  0: Action=3  1/2h=15 -> 07:30  Day=3  [6]=2   namelen=9  "TEST1.mmb"
  record @260: Action=0  1/2h=39 -> 19:30  Day=3  [6]=16  namelen=0  (no setup)

Five independent confirmations, no fitting:
  1. Slots 15 and 39 match the stated 07:30 and 19:30 on a 30-minute grid, and
     39-15 = 24 slots = exactly 12 hours.
  2. The length byte reads 9 for TEST1.mmb, 40 for the long name in the read
     capture, and 0 for the Auto Call Home entry.
  3. Auto Call Home carries NO setup name -- direct proof that a schedule entry
     can exist with no setup attached, which is what the earlier
     DUTYCYCLE_START_MONITOR finding predicted from the firmware side.
  4. The 260-byte stride lands record 2's 1/2h exactly at [264].
  5. 2 x 260 + 4 = 524, the whole body, nothing left over.

CORRECTION: `27 03 10` at [264] was recorded in the previous commit as a possible
trailer.  It is record 2's 1/2h, Day and [6] fields.  I had assumed the file held
one record and read the second one as padding -- the non-zero bytes were sitting
there the whole time.

Still open: [6] (2 on the start entry, 16 on the ACH entry -- a Repeat or Day/Week
capture would isolate it), the four remaining action codes, and whether the file
can hold unused record slots.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-24 21:40:05 -04:00
serversdownandClaude Opus 5 508448e2dd docs(series4): the schedule record format, named by the firmware itself
A debug printf in the scheduler names the record's fields outright:

  SCHEDULER : _ReadRecord(%d) -> %s (Action=%u, 1/2h=%u, Day=%u, Setup="%s") [WDAY=%d]

They fit the captured record, and the name-length byte anchors the alignment --
it reads 40 for the 40-character name pulled off the unit and 9 for TEST1.mmb
written back, same position, both directions:

  [0]     Action = 3
  [1:4]   zero (padding, or Action is a uint32)
  [4]     1/2h = 15   -> 30-minute resolution, 48 slots/day
  [5]     Day = 3
  [6]     unidentified (WDAY?)
  [7]     name length -- 0x28=40 read, 0x09=9 written  <-- confirms the layout
  [8:]    setup name
  [264]   trailer 27 03 10

Slot 15 would be 07:30 counted from midnight; flagged unconfirmed because the
schedule's actual time was not recorded with the capture.

Six duty-cycle actions, not the five previously recorded -- there is also
DUTYCYCLE_START_MONITOR_WITH_SETUP_STOP_COMPLETE.  THOR exposes four.  Two start
variants it never offers, one needing no setup file.

Strengthened the setup-less-action finding and ruled out an alternative
explanation I had not considered: the Micromate has a separate Timer Mode
(MODE_TIMER, Monitor Once Only, under Special Setup), so START_MONITOR could have
belonged to that path.  It does not -- it is a case in _PSA(), the scheduler's own
dispatcher for _ReadRecord's Action field, and `_PSA() send ->> CMD_DUTYCYCLE_
START_MONITOR` shows it is live code sending a real message, not a dead case.

Also: SysPref.bMonitorScheduler places the scheduler enable in system
preferences, which confirms from the other side why the 0x71 block was
byte-identical when the scheduler was switched on -- the flag was never going to
be in the compliance config.  It also suggests 0x47 is a SysPref get/set rather
than anything scheduler-specific, which would explain its params[7] selector and
its response shape matching 0x48's page-0 descriptor.  Still a hypothesis.

Names the one capture that would settle the rest: a schedule with TWO entries at
different times with different actions.  That yields the record stride, the action
code values, and the time encoding at once.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-24 20:29:51 -04:00
serversdownandClaude Opus 5 3f58402085 docs(series4): the ACH session, from the THOR manual -- and I was asking the wrong question
Brian uploaded the Instantel manuals (gitignored, manuals/).  The THOR Operator
Manual Rev 08 settles the thing this document called the blocker for a homebrew
receiver.

I had written that what gates a receiver is "how it learns an event was accepted
so it stops re-sending it."  There is no such mechanism to find, because the unit
does not track it.  Per THOR manual 6.2.2.2 an ACH session is a list of
SERVER-chosen actions -- Copy events, Copy monitor log, Delete events and Logs
from Unit, Set Date/Time -- and "Only applies to events not previously
downloaded" is computer-side bookkeeping.  The manual's own warning proves copy
and delete are decoupled: enable delete but disable copy and "the events and logs
will be deleted without being uploaded."

That is exactly the model our Series III ACH server already implements
(ach_state.json high-water mark, erase as a deliberate separate step).  No new
mechanism is needed for Series IV.  A receiver needs: accept, identify, walk the
events (already solved), keep our own high-water mark, optionally erase.  The
ERASE OPCODES are now the only genuinely missing piece and stay on the unsafe
list.

Other things the manual settles:

  * The session is server-driven, matching the firmware state machine.  Scheduled
    and event-triggered ACH differ: with Monitoring While Calling Home enabled, an
    event-triggered session will NOT delete events or sync time.  So a receiver
    that relies on erase to avoid re-reading would silently never erase on those
    units -- the high-water mark has to be primary, erase an optimisation.
  * Session Time Out is unit-side only, which places it in callhome.MMB -- another
    reason to read that file with 0x94.
  * Units are routed by serial number with wildcards, so the serial is presented
    early enough for a server to dispatch on it.
  * THOR requires Idle for ACH setup too, confirming the greyed-out send is
    deliberate policy rather than a device refusal.
  * THOR exposes four schedule actions; the firmware has five.  6.3.2 step 8
    ("A Unit Setup must exist") is THOR's own requirement, while the same section
    says the unit "will execute any actions in a schedule using its current
    settings" -- the two pull opposite ways, consistent with START_MONITOR
    existing and THOR never emitting it.
  * Schedule fields to look for when the entry is decoded: action, setup name,
    time, day-or-week, day selection, repeat.  The captured entry has seven bytes
    before the name, the right order of magnitude for that list.

Flagged: the manual's filter example contradicts its own table (it has UM* and MP*
backwards).  The table is right.

Marked throughout as vendor documentation rather than observed bytes.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-24 20:02:30 -04:00
serversdownandClaude Opus 5 8c2dacf035 docs(series4): the schedule has a setup-less start action -- Thor never uses it
The schedule<->config coupling looked like it might be a workaround for the unit
crashing on a missing setup.  The firmware says otherwise: there are two distinct
start-monitoring actions in the scheduler's duty-cycle dispatch, and only one
involves a setup file.

    _PSA() case DUTYCYCLE_START_MONITOR
    _PSA() case DUTYCYCLE_START_MONITOR_WITH_SETUP

Full action set: START_MONITOR, START_MONITOR_WITH_SETUP, STOP_MONITOR,
CALLHOME, SELF_CHECK, plus ON/OFF/NEXT for scheduler state.

So the coupling is not a crash workaround -- Thor picks the more demanding of two
available actions every time.  SFM can emit START_MONITOR and skip the config.

On whether a missing setup would actually break the unit: the firmware suggests
graceful degradation (`Setup File Not Found`, and `Invalid parameters reset to
factory default - please review setup`, a deliberate fallback).  Untested, and
recorded as untested.

Hypothesis, flagged as such: the schedule entry's leading byte may be the action
code -- the one captured entry reads `03 00 00 00 0f 03 02 [namelen][name]` and
03 would fit START_MONITOR_WITH_SETUP.  One entry, nothing to diff, unverified.

Names the capture that would settle it, and which is worth more than the 0x47
disable/enable test: a schedule entry with a setup-less action (stop monitoring,
or call home).  It would confirm or kill the action-code hypothesis and prove
from the other direction that a schedule needs no config push.

Also noted: DUTYCYCLE_CALLHOME -> CMD_SCHEDULE_CALL_HOME means a scheduled
call-home can make a unit dial out on demand -- the one remaining lever on the
unsolved call-home direction.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-24 19:49:59 -04:00
serversdownandClaude Opus 5 ebcc55e2ec docs(series4): the schedule<->config coupling is Thor's, not the protocol's
In Thor, a schedule entry that starts monitoring forces you to attach a setup,
and sending the schedule pushes that setup too, overwriting anything with the
same name.  The protocol requires none of it.

Evidence from the scheduler capture:

  * The two writes are separate operations, not one transaction.  The config
    write ends at frame 18, Thor sends a fresh POLL preamble, and only then opens
    the schedule at frame 20.  Different commands, different paths:
        config    0xDA -> 0x68/0x73 -> 0x82/0x83 -> 0x71/0x72
        schedule  0x8D -> 0x8E
  * The schedule stores a length-prefixed NAME, not a config blob.  It is a
    reference, and a reference does not require rewriting its referent.
  * The config Thor pushed was already on the unit unchanged -- its 2,090-byte
    0x71 payload is byte-identical to the previous capture's, zero differences.
    Thor spent a whole block write re-sending a setup the device already had.

So SFM can, with today's protocol: enumerate setups with 0x3F/0x40, write ONLY
the schedule when the referenced setup already exists, and push a config only
when it is genuinely missing or deliberately edited.  Common case drops from
524 + 2090 bytes to 524, and the write disappears entirely.

It also removes a real hazard.  Because the reference is by name, and a same-name
write overwrites silently with an indistinguishable ack, Thor's pattern means
scheduling something can quietly rewrite a setup that other schedules or the
operator's own work depend on.  Validating the reference instead of rewriting the
referent avoids the class of problem.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-24 19:46:09 -04:00
serversdownandClaude Opus 5 bd876b6752 docs(series4): separate Thor's conventions from the protocol's requirements
SFM is not meant to reimplement Thor.  Thor is the only available teacher of the
wire protocol, but almost nothing about how it sequences its work has been shown
to be required by the device, and this document was starting to blur the two --
it said "a client should mirror it" where the honest claim is "Thor does this and
we have not checked whether the unit cares."

Adds a table separating the two, with required / not-required / unknown marked
honestly, and corrects the two places that gave Thor-copying advice.

The consequential unknowns, all testable:

  * Thor's POLL -> 0x15 -> 0x49 -> POLL preamble before EVERY operation.
    Plausibly required (Series III needed POLL x3 before 5A) but Thor sends it
    before trivial reads too.
  * 0x68 and 0x82 appear in every setup push carrying near-zero payloads that
    changed nothing in either capture.  If optional, our setup write is 3 frames
    instead of 7 with less to get wrong.  Worth settling BEFORE building the
    writer.
  * Whether a narrower write than the full 2,090-byte block is accepted.

One place Thor's shortcut is probably worse than the alternative: it reads with
offset=0xFFFF and skips the probe, but the probe works and reports the length
rather than making us trust a fixed one.

Two reliability problems to design against, both observed rather than assumed:
a zero ack does not mean a write applied (no failing write has ever been seen),
and nothing warns before clobbering a monitoring unit's active setup.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-24 19:44:05 -04:00
serversdownandClaude Opus 5 c5eed6fa46 docs(series4): RETRACT "no file transfer" -- 0x94/0x48/0x8D/0x8E read and write by path
The scheduler capture caught a generic file transfer in the open, and it
invalidates a claim made earlier today.

RETRACTION.  The "Setups are FILES" section concluded "no generic file-transfer
command is exposed on the wire", reasoning from the absence of firmware strings.
Wrong.  The commands exist, they carry a full filesystem path in plain ASCII,
and they were the first thing Thor did when asked for the schedule:

    0x94 <path>  -> 0x6B   open for read
    0x48         -> 0xB7   read next page, until an all-zero response = EOF
    0x8D <path>  -> 0x72   open for write
    0x8E <body>  -> 0x71   write the body

Path is unpadded with offset = its exact length; 0x94 and 0x8D sent byte-
identical payloads for "\system\schedule\schedule.dat".  The 0x48 read is paged
with the page number in the response header at payload[3:5].

The lesson: absence of a firmware string is not absence of a command.  Dispatch
is a 68K jump table and these carry no strings.  The setups half of the original
claim survives -- setups go via 0xDA plus the config block, not via this.

Why it matters beyond the scheduler: callhome.MMB is a file too, and call-home
is the last unsolved goal.  Reading it may be a matter of pointing 0x94 at the
right path.  Recorded as a lead -- no path but schedule.dat has been tried.

The schedule file: an entry carries a length-prefixed SETUP FILE NAME (0x28=40
for the name read off the unit, 0x09=9 for TEST1.mmb written back -- confirmed
both directions).  So a schedule entry says "at this time, load this setup",
which is how the help text's "change the record mode" works, and it couples the
scheduler to the setup list.  Entry internals are NOT decoded and are recorded
as observed bytes only -- one entry, no variation to diff.

SUB 0x47 is the scheduler enable, probably: two bare frames differing only in
params[7] (0x01, 0x03).  Whether it sets or reads is genuinely undetermined --
both returned the same value and there is no disabled reading to compare.
Flagged do-not-implement until a disable-then-enable capture settles it.

A prediction made before the capture -- that the Scheduler On/Off switch would
show up as a byte in the 0x71 block, since the unit's help text lists it beside
Record Mode -- did not hold.  0x71, 0x68 and 0x82 are byte-identical to the
previous capture.  Noted that the test is weak (the operator re-sent the same
config), but enabling the scheduler required no config write either way.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-24 19:26:39 -04:00
serversdownandClaude Opus 5 5400f1bef7 docs(series4): monitoring control, the setup-list walk, and the device clock
Thor started monitoring, listed the unit's setups and stopped monitoring while
seismo_lab recorded.  40 requests, 40 responses, every checksum valid.  As
before, Thor did all of it -- we have still never originated any of these.

Confirmed identical to Series III:

  * SUB 0x96 start monitoring -> ack 0x69
  * SUB 0x97 stop monitoring  -> ack 0x68

Both bare frames, no params, no data.  These were on the unsafe-until-agreed
list as entirely unobserved; they are now observed but still never sent by us.
Erase (0xA3/0xA2) is now the only genuinely untouched destructive path.

NOT identical to Series III, and worth not reusing constants for:

  * The monitoring flag is SUB 0x1C data[12] = 0x0E monitoring / 0x00 idle.
    Series III uses 0x10.
  * SUB 0x49 -> 0xB6 is a second, cheaper monitoring indicator at data[11]
    (0x02 monitoring / 0x00 idle) in a 21-byte response rather than 60.  Thor
    puts it in its preamble before every operation, so it is the routine check.

New this capture:

  * SUB 0x1C carries the DEVICE CLOCK at data[13:21] -- day, month, year (u16
    BE), hour, minute, second.  Verified against the capture's own wall time.
    Nothing else read so far reports the unit's time.  data[17] remains
    unidentified (32 monitoring, 100 idle) -- not claimed as anything.
  * Memory total is exactly 15,000,000 bytes; free dropped 4,096 bytes across a
    ~70s monitoring session, so free memory is not stable to compare against.
  * SUB 0x3F/0x40 walk the setup-file list, the same first/next shape as
    Series III's 1E/1F event walk.  0x3F -> 0xC0 first, 0x40 -> 0xBF next,
    terminating on an empty name.  23 setups on this unit.
  * Setup records carry ONLY the name -- 11-byte header, null-terminated name,
    zero padding.  There is no active-setup flag; the header is byte-identical
    on every record including the terminator.  The active setup is identified
    solely by SUB 0x41, which uses the same record format.  The asterisk on the
    unit's screen is UI decoration, not a field.
  * TEST1.mmb, created over the wire earlier today, appears in the list and is
    what 0x41 reports as active -- a written setup becomes a real enumerable
    file.

Also: Thor greys out send-to-unit while a unit is monitoring, and transmits
nothing (this capture contains no 0xDA or 0x71).  That is Thor policy, not a
device refusal -- nothing suggests the Micromate would reject it, and a push to
the active setup overwrites silently.  Thor is guarding the footgun the protocol
leaves open, and any client we write should do the same.  Checking 0x49 data[11]
first makes that cheap.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-24 19:18:58 -04:00
serversdownandClaude Opus 5 b5e34ce8ae docs(series4): overwrite is protocol-identical to create -- no handshake
The firmware carries `Overwrite File`, `MFS FILE EXISTS` and `Cannot be
Overwritten`, which suggested the wire path might negotiate an overwrite.  It
does not.  Those strings belong to the on-device Save screen (CSaveSetupFile),
not the protocol.

A second Thor push to TEST1.mmb -- a name that now existed, and which SUB 0x41
confirmed was the ACTIVE setup -- produced an identical sequence:

  * same 12 SUBs in the same order, same offset fields
  * 0xDA / 0x68 / 0x82 data byte-identical
  * 0x71 differs in exactly 18 bytes = the one edited note string
  * all seven write acks identical and still all-zero
  * no dialog on Thor

Verified on the unit: the edited General Notes string is present in the setup on
the device.  The write applied silently and in place, and being the active setup
bought it no protection.

Two consequences recorded:

  * A writer needs no exists-check and no overwrite negotiation.
  * We have never seen this protocol report a FAILED write -- acks are all-zero
    across create and overwrite alike.  Do not treat a zero ack as proof a write
    applied; read back with 0x41 + 0x1A and compare.  And a remote push to a
    monitoring unit's active setup changes what it is recording with, unprompted
    -- gating that belongs in SFM, because the device will not do it.

Still untested: overwriting a non-active setup, and factory.MMB.  Neither
blocks a writer.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-24 18:56:20 -04:00
serversdownandClaude Opus 5 d33e2d85be docs(series4): 0xDA creates setup files -- confirmed on the device
TEST1.mmb did not exist on UM12947 before the push.  After it, the setup is
present in the unit's own setup list and selected as active -- verified on the
Micromate's screen, not inferred from the ack.

This was the last open question about whether Series IV setup management is
reachable without Thor.  It is: 0x41 read name, 0x1A read block, 0xDA name the
target, 0x71 -> 0x72 write it back.  No file-transfer primitive is needed and
the target file does not have to exist.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-24 18:48:17 -04:00
serversdownandClaude Opus 5 c8d972f685 docs(series4): the setup-write path, observed end to end
Thor pushed a setup named TEST1.mmb to UM12947 while seismo_lab's TCP bridge
recorded both directions.  We still have not originated a write frame -- the
wire format is now known, our encoder is not written.

Topology worth reusing: socat shares /dev/ttyACM0 on TCP from mint-mac,
seismo_lab relays Thor to it.  Thor is pointed at 127.0.0.1 as if the unit were
a field modem.  No modem, no SIM, production Thor box untouched.

The sequence is Series III's, plus one command:

    Thor:  5B | 41 | 08 | 2E | 1A | DA | 68->73 | 82->83 | 71->72
    unit:  A4 | BE | F7 | D1 | E5 | 25 | 97  8C | 7D  7C | 8E  8D

All 12 device responses checksum-validate and every write is acked.  Every
write response SUB matches the Series III table exactly.

New:
  * SUB 0xDA names the target .MMB file -- 256 bytes, filename null-padded,
    nothing else.  This is why no generic file-transfer command exists: Thor
    names the file, then writes the ordinary config block into it.
  * SUB 0x41 reads the active setup's filename; SUB 0x2E reads trigger config.
  * Reads are single-step -- Thor asks offset=0xFFFF and skips the probe.
  * 0x71 writes the whole 2090-byte block in ONE frame, not Series III's three
    chunks.  0x69/0x74 are absent.

Write-frame destuffing is `10 XX` -> `XX` uniformly, including `10 03`.  Chosen
by checksum, not assumption: of four candidate rules, only this one makes all
four data-carrying write frames validate.  0x71's data holds 4 literal 0x03
bytes escaped as `10 03`, so escaping is mandatory for any writer.

The write body IS the read body -- 0x71 and the 0xE5 response align at a fixed
11-byte shift with 1902/2090 bytes equal (91.0%).  Setups are read-modify-write.
The 12 differing regions are fully mapped: setup name, four 64-byte
[label:22][value:42] note entries, sensor location, and the three geo trigger
levels (0.3 -> 0.5 in/s) on a 48-byte channel stride.

Independent confirmation of the geo LSB: each channel block carries float32BE
3.10308 at label+24.  3.10308/10000 = 0.000310308 = _GEO_LSB_IPS to 8 figures,
and 10.0/3.10308*10000 = 32226.046 = the 32226.05 full scale.  That value was
derived statistically from 991,415 rounding constraints in v0.30.0; the unit
reports it directly.  It is exactly half Series III's 6.206053, so the ADC runs
10,000 counts per volt.  Do NOT retune _GEO_LSB_IPS -- this corroborates it.

The `offset` field is NOT a single length formula: two frames are len, two are
len+2, and Series III's data[1]+2 reproduces neither.  Recorded as observed
constants the device accepted; pinning the rule needs a capture with
differently-sized payloads.  This doc has been wrong once by inferring a length
field -- not inferring this one.

Also adds scratch/mm_frame_parse.py, because S3FrameParser cannot see Micromate
responses at all (it scans for DLE+STX; Micromate responses start at a bare
STX).  That is why the first pass at this capture looked like 12 unanswered
requests.  24/24 frames parse with 0 bad checksums.

Stale claims corrected: the "write half is not yet attempted" note, the
"empty unit" limitation (5 events since 2026-09-23), and the unsafe-until-agreed
list, which now distinguishes observed from exercised.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-24 18:35:58 -04:00
serversdownandClaude Opus 5 701af47170 docs(series4): generate IDF filenames rather than detecting record type
Closes the record-type gap flagged earlier, and corrects the premise behind it.

Series III does NOT detect record type from file content --
event_file_io.derive_record_type_from_filename() reads the last character of
the extension (M529LKIQ.G10H -> H -> Histogram). Nothing in the codebase infers
record type from content, for either family.

Nor is there an obvious type field to find in an IDF: the first 64 bytes of a
histogram and a waveform are byte-identical, and they diverge at ~0x0947 into
wholly different structures rather than differing by a flag.

The answer is the Series III pattern -- generate the name. Series III has
blastware_filename(); Series IV needs the same, and its convention is far
simpler:

    <serial>_<YYYYMMDDHHMMSS>.IDF{W,H}     e.g. UM12947_20260923163319.IDFW

against Series III's <letter><serial3><base-36 stem><AB0T ext>.

All three inputs are already available on a direct download: serial and
timestamp from extract_binary_metadata(), and type from the chain walk (SUB
0x0A returns 0x1E for a histogram, 0x00 for a waveform). Verified on all five
bench events -- generated names match real production-store filenames byte for
byte, so a directly downloaded event can be filed under exactly the name Thor
would have given it and /db/import/idf_file needs no change.

The type still comes from the protocol rather than the payload, so a
downloader must carry it out of the chain walk; losing it means losing the
ability to name the file.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-23 19:50:45 -04:00
serversdownandClaude Opus 5 02ed22f561 docs(series4): firmware static analysis, and all five bench events decoded
Solo session while the bench was unattended. Read-only throughout.

Architecture: ColdFire/68K, big-endian, Freescale MQX RTOS -- not ARM as the
vector table first suggested. The tell is 4E 5E 4E 75 4E 56 (UNLK A6 / RTS /
LINK A6) throughout both images, plus an MQX_OK assertion.

CB vs BD: a byte diff is useless (68% of bytes differ -- separately linked
builds, everything relocated). A string-set diff is position-independent and
shows 17,128 strings shared, with almost every "unique" string being the same
message at a different source line:

    CB:  MONITOR[3268]: STATUS_BATTERY_LOW
    BD:  MONITOR[3258]: STATUS_BATTERY_LOW

Consistently 10 lines apart across five different MONITOR messages, so one
~10-line block differs in the monitor module and essentially nothing else. The
only functional string unique to either build is CITIZEN (a printer brand) in
BD. This corroborates the bench A/B from the other direction: the split is a
tiny code delta, not two protocol stacks.

The SUB dispatch is a 68K switch jump table, so byte-pattern hunting will not
isolate the write opcodes -- that needs a disassembler.

Call-home config field names recovered from the firmware's own debug dump:
Enable, DialString, Retries, SessionTimeout, WaitForConnection, WarmupTime,
PowerSave -- seven fields for the 126-byte SUB 0x2C block. SessionTimeout and
PowerSave have no Series III equivalent, and Series III's scheduled-time fields
are absent, consistent with scheduling moving into the THOR-downloaded
scheduler. AT+CSQ is present, so the firmware speaks AT to the modem directly.

All five bench events downloaded and decoded over USB: each arrived at exactly
its declared size, every channel equal length, timestamps sequential.

Two gaps recorded:

- No content-based record-type discriminator. read_idf_file() dispatches on the
  .IDFH/.IDFW filename suffix, which does not exist over the wire, and the
  first 64 bytes of a histogram and a waveform are byte-identical. The protocol
  supplies one instead: SUB 0x0A returns 0x1E for a histogram and 0x00 for a
  waveform, so the type must be carried from the chain walk.
- The 0x0C peak float runs 2-5% above max(Tran,Vert,Long) and is not the vector
  sum either. Its offset was inferred from a byte marker rather than
  established, so it may not be the peak at all. Marked do-not-rely-on.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-23 19:14:26 -04:00
serversdownandClaude Opus 5 23cdbef737 docs(series4): setups are files; and the length field is a uint16
Two findings and one correction.

CORRECTION: the probe response's data length is a uint16 BE at payload[8:10],
not a single byte at payload[9] as an earlier draft claimed. That reading is
right only while the high byte is zero. For SUB 0x1A the real length is 0x082C
= 2092; read as a byte it gives 44, a 47x under-read.

Setups are FILES, not a config block. Series III has one compliance config you
overwrite; Series IV keeps named .MMB setup files on an on-device filesystem
with a current-selection pointer -- csetup.MMB, factory.MMB, and callhome.MMB
for the call-home config. Names up to 20 chars. Filesystem primitives exist
internally (NS_ReadFile_internal / NS_WriteFile_internal / NS_SeekFile_internal)
but no generic file-transfer command is exposed on the wire, so setups are
unlikely to be pushed as raw .MMB blobs over the protocol.

SUB 0x1A reads the whole active setup in 2,092 bytes -- structurally close to
Series III's ~2,126-byte compliance block -- carrying the setup FILE NAME, all
four title note/value pairs (Location, Client, Company, General Notes), the
sensor location, and per-channel labels with units. Note LMic and SMic
(linear and sound-level microphone variants) which Series III does not have.

That is the read half of setup management, so a setup can in principle be
round-tripped. The write half has not been attempted.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-23 18:55:20 -04:00
serversdownandClaude Opus 5 71f19c90d1 docs(series4): SUB 5A streams the .IDFW file verbatim -- read path complete
The complete read path now works with no Instantel software in the loop.

Three divergences from Series III, all simplifications:

- No arming sequence. Series III ignores a 5A probe unless preceded by
  1E / 0A / 1E(0xFE) / 0C / 1F(0xFE) / POLL x3. The Micromate answers a bare
  5A request with nothing before it.
- The offset word is a LENGTH, not a position: 0x1000 + 2*pages, where
  pages = ceil(event_size / 512), and event_size comes from the chain walk.
  ONE request returns the entire event -- no chunk loop, no STRT end-offset
  parsing, no TERM frame. Over-requesting is safe; the device caps at the
  real size.
- Params are the Series III probe form: [0x00][key4][6 x 0x00].

The payload is the .IDFW file byte for byte. It begins 00 12 01 00 00 00
"Instantel\0" -- _THOR_PREFIX + _INSTANTEL_TAG from micromate/idf_file.py --
and the first 32 bytes are identical to a production .IDFW from the store.
Responses are DLE-stuffed, so destuff before locating the file (11,781 raw ->
11,049 destuffed for an 11,032-byte event).

End-to-end: event 055d4a82 downloaded over USB and fed straight to
read_idf_file() yields serial UM12947, timestamp 2026-09-23 16:33:19, and
3072 samples on all four channels. Cross-check: the 0C record reports a
stored Vert peak of 1.3720 for this event; the decoded samples give 1.3706 --
two unrelated paths agreeing to 0.1%.

Consequence: no new codec work is needed. The bytes off the wire are the same
bytes thor-watcher forwards today, so /db/import/idf_file ingests a directly
downloaded event unchanged.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-23 18:40:54 -04:00
serversdownandClaude Opus 5 45007e12d8 docs(series4): the firmware images are unencrypted and self-documenting
Both MICROMATE(CB).BIN and MICROMATE(BD).BIN are plain code and data --
entropy 6.08 bits/byte, big-endian vector table at 0x4010_30xx, ~16,700
extractable strings including the developers' own debug printf formats with
function names intact.

This answers, from strings alone, questions I had scoped as needing a live
modem capture.

The call-home state machine, verbatim:
  ACH_NOT_STARTED -> ACH_IDLE -> ACH_INITIALIZING -> ACH_CONNECTING
  -> ACH_CONNECTED -> ACH_TRANSFER_DATA -> ACH_RETRY / ACH_QUITTING

And with it:

- Retry limit is three ("three attempts and it's over").
- ExpectedCommunicationsDetected() gates the session: if the host does not say
  something the unit recognises, the call is cancelled and rescheduled after
  TimeBetweenRetries. A homebrew receiver must satisfy this check or units
  retry forever -- exactly the BE12599 failure mode.
- The unit stops monitoring to call home and restarts after
  (Send CMD_STOP_MONITOR / CMD_START_MONITOR), so monitoring state around a
  call is the device's own doing.
- Calls are not re-entrant.
- CMD_CALLHOME_CONNECTION_CONFIRMED exists as a state distinct from
  CONNECTION_COMPLETE, implying a handshake the host must complete before data
  flows.

Event delivery, inferred not confirmed: "All Events Uploaded" plus
"Mark/Unmark File" / "Delete Marked Events" / CMD_PURGE_EVENT_FLASH suggest
events are marked as transferred rather than deleted on send, with purging a
separate explicit act. If so, a receiver that fails to mark would see the same
events re-offered every call. Needs a live capture or disassembly to confirm.

The firmware also embeds its own HTML user manual, documenting modem mode
(Generic vs USB to PC), the modem baud options (9600-230400, confirming 115200
is a setting not a fixed rate), modem relay/warmup, record modes, and a
scheduler downloaded from THOR that pairs with CMD_CALLHOME_SET_SCHEDULE.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-23 18:28:40 -04:00
serversdownandClaude Opus 5 38ad58d4a4 docs(series4): A/B the two firmware lines -- the protocol is the same
UM12947 (11.0CB, Blastware line) and UM20147 (11.0BD, Thor line) each given
the identical read-only sweep on the bench. Both answer Series III command
frames: all ten read SUBs, correct response-SUB rule, valid DLE-aware
checksums, working two-step probe/data reads.

The firmware line does not change the wire protocol. One protocol stack can
drive the whole fleet regardless of build, which downgrades "standardise the
fleet on one firmware" from a prerequisite to an optional convenience.

Two differences do exist:

1. Response payload[1] (flags) is 0xC5 on the Blastware line and 0x03 on the
   Thor line, constant across all ten SUBs on both units -- so the build is
   detectable from any response without reading device info. Two units, one
   each, so this is a strong hypothesis rather than a proven encoding.

   Note 0x03 is ETX, so it arrives DLE-escaped as 10 03 on Thor-line units. A
   parser that does not destuff will mis-locate every field by one byte on
   half the fleet.

2. SUB 0x1C (monitor status) is 4 bytes longer on the Thor line, 0x30 vs
   0x2C, with four extra trailing bytes (0f a0 00 00, purpose unknown).

That second one breaks relative-to-end parsing: Series III reads battery and
memory from the end of the 0x1C block, and those offsets yield a battery
reading of 577.92 V on UM20147. Parse forward from the declared length, not
backward from the end. With the shift applied, UM20147 reads 3.81 V and
15,000,000 bytes total/free.

Also noted: ID string is MM/ISEE/S/IO on the Blastware unit and MM/ISEE/S on
the Thor one.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-23 18:20:11 -04:00
serversdownandClaude Opus 5 492b6683a4 docs(series4): fleet firmware audit, and retract the Thor-compatibility claim
Physical audit of all nine Micromates: 4 on the Blastware line (11.0CB), 2 on
the Thor line (11.0BD), 3 pre-split (11.0AK x2, 10.90GC). The Blastware line
is already the plurality, which makes "standardise on Blastware" less
disruptive than it first looked.

Cross-checked against a store-derived audit (firmware is recorded in every
.sfm.json as extensions.idf_report.version): 7 of 9 agree. The two that differ,
UM6047 and UM14133, are the most recently deployed and were reflashed after
their last stored event -- so the store reconstructs firmware history without
touching a unit, but lags reality by one deployment.

RETRACTION: an earlier draft suggested UM12947's trouble with Thor was
explained by its Blastware firmware. Not supported. Ped Bridge runs UM11402
(11.0BD) and UM11719 (11.0CB) side by side from the same deploy date and both
call Thor fine -- UM11719 has 331 Thor-collected events while on 11.0CB. A
Blastware-line unit does feed Thor, so the CB/BD split is not "which host can
collect from it", and UM12947's problem remains unexplained.

What is actually established is narrower: a 11.0CB unit answers Series III
command frames. Whether a 11.0BD unit does is untested -- and UM20147 (11.0BD)
is on the bench, so that is one A/B away.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-23 17:08:47 -04:00
serversdownandClaude Opus 5 73eaa0a6ac docs(series4): the event chain, walked end to end
Five events on the bench unit (4 waveform + 1 histogram). The Series III
browse walk -- 1E, then 0A/0C per key, then 1F to advance -- works unmodified,
and the null sentinel terminated correctly after exactly 5.

Findings:

- Event keys are a sequential counter (055d4a81..85), NOT flash-buffer
  addresses. Series III key arithmetic does not carry over; its 5A chunk walk
  assumes addresses and must not be ported blindly.
- The 4 bytes after the key in 1E/1F are the event's SIZE in bytes, where
  Series III puts an offset to the next key. 4,076 for the histogram and
  8.7-13.4 KB for the waveforms, matching real .IDFH/.IDFW file sizes.
- SUB 0x0C returns a 210-byte (0xD2) waveform record -- the same length as
  Series III -- carrying the event key, date/time, the title note "Location",
  the PROJECT STRING, the serial, channel labels Tran/Vert/Long/Mic and
  float32 peaks.

That last point closes the biggest open question for the call-home receiver:
the job identity strings that today arrive only via Thor's .txt sidecar, and
which no amount of sample decoding can reconstruct, are readable over the
wire. Direct-to-SFM events need not arrive with blank metadata.

- SUB 0x0A returns len 0x1E for the histogram and 0x00 for every waveform. The
  histogram payload holds two timestamps plus a "Vert: 0.300 in/s" trigger
  string -- structurally the Series III monitor-log partial record. So 0A
  describes interval records and 0C describes triggered events; Series III's
  0x46-vs-0x2C length discriminator does not apply.
- DLE stuffing in responses is now confirmed (previously marked untested): the
  0C timestamp contains 10 10, which destuffs to one 0x10 and yields a clock
  reading of 16:33 on 23 Sep 2026 -- matching when the events were recorded.

Read-only throughout.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-23 16:39:11 -04:00
serversdownandClaude Opus 5 b9c52442a7 docs(series4): the Series III behaviour is firmware-conditional
The bench unit reports 11.0CB -- Instantel's *Blastware* firmware line. It
almost certainly answers Series III commands because it is in Blastware mode,
not because the Micromate natively speaks Series III. Instantel ships two
lines: 11.0CB (Blastware) and 11.0BD (THOR, Vision, Vision II).

That also explains the two-ACH-server problem as designed behaviour rather
than misconfiguration.

Corpus firmware audit: 932 event files from 11.0AK, 83 from 10.90GC. UM12947
itself produced 10.90GC files in production last year and reports 11.0CB now,
so units get reflashed and firmware is not stable per-unit over time.

Records the resulting strategic fork (standardise on the Blastware line vs
reverse-engineer the Thor line) with the four unknowns that decide it.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-23 16:04:42 -04:00
serversdownandClaude Opus 5 095834183e docs(series4): open the Micromate live-protocol reference
First bench session against a Micromate over USB. The headline: the unit
answers Series III command frames unmodified.

An untouched Series III POLL (SUB 0x5B), built by build_bw_frame with no
changes, completed a full two-step probe/data cycle. Ten Series III read
commands were then tried and all ten answered, every one obeying the
response_SUB = 0xFF - request_SUB rule.

Confirmed this session:

- Transport is a plain USB CDC-ACM port (2504:0300, "MICROMATE COM PORT").
  No vendor driver, no Thor, no Windows box needed. Baud is ignored over USB
  (identical responses at 38400 and 115200).
- Device never speaks first -- 20 s idle listen produced nothing.
- Responses are Series III framing MINUS the leading DLE: bare
  [STX][payload][chk][ETX]. This alone means Blastware can never find a frame
  boundary in Micromate traffic, since its parser scans for DLE+STX.
- Response flags byte is 0xC5, not Series III's 0x10.
- Checksum is the DLE-aware variant (SUM8 excluding 0x10 bytes) -- the same
  one Series III uses for 5A and write frames, not the plain SUM8 of its
  ordinary reads. Disambiguated by the POLL data frame, which contains a 0x10.
- The probe response carries the data length at payload[9]. Four of four
  known Series III lengths match; call-home config differs (0x7E vs 0x7C).
- Series III monitor-status field offsets apply unchanged: battery 3.81 V
  (Thor's own reports say 3.8), memory 15,000,000 total and free, date
  23 Sep 2026.
- SUB 0x2C carries the string "RADIO RING" -- the same string seen in the
  RV50 ALEOS debug during the BE12599 incident. That block holds the modem
  dial/answer strings and is the most relevant command to the call-home goal.

Read commands only. Nothing that writes, erases, or changes monitoring state
has been sent to a unit; those are listed as unsafe-until-agreed.

Caveat recorded in the doc: one unit, over USB, with zero events stored, so
the event-walk commands (0x08, 0x1E, 0x0A, 0x06) could only be probed, not
exercised.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-23 15:59:17 -04:00
serversdownandClaude Opus 4.8 154186a6cd Merge feat/event-timestamp-fix: exact waveform trigger time from the binary
read_blastware_file stamped waveforms with footer ts1 (the monitoring-session
start, hours off — vomit-list #3).  The event time is ts2 (recording stop) and
the trigger = ts2 - record time, a float32 in the recording-setup config block,
so the exact Blastware trigger is recovered from the binary alone (no .TXT).
Histograms keep ts1; a paired report's event_datetime stays authoritative.

Needs a re-decode backfill to correct existing stored events' timestamps.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-20 23:13:19 +00:00
serversdownandClaude Opus 4.8 1765b3300d docs(changelog): waveform event-time fix (exact trigger from binary)
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-20 22:32:13 +00:00
serversdownandClaude Opus 4.8 1e76d08b37 fix(decode): recover the exact waveform trigger from the binary (no .TXT)
Follow-up to the ts1→ts2 fix: get the trigger to the second from the binary
alone, instead of falling back to the stop time (~record-duration late) for
no-report events.

The configured post-trigger record time is a big-endian float32 in the
recording-setup config block, exactly 30 bytes before the "Standard Recording
Setup" marker.  _parse_record_time_seconds reads it; the waveform branch now
stamps trigger = ts2 - record_time.  Verified: the field reads 1.0 / 2.0 / 3.0 s
across different setups in the corpus, and all 7 BE12844 oracle events now
decode to their exact Blastware trigger (N844LQHB 10:33:29) from the binary,
no paired .TXT needed.  Falls back to ts2 (the stop) if the config block is
absent.  A paired report's event_datetime stays authoritative (clock drift).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-20 22:31:22 +00:00
serversdownandClaude Opus 4.8 a84a46e9d4 fix(decode): stamp waveform events with the event time, not the session start
read_blastware_file built ev.timestamp from footer ts1, which for a WAVEFORM is
the monitoring-session start (a unit arming at 06:00 stamps 06:00 on every event
that day) — so every waveform's time was hours off (vomit-list #3, "~4.5 h off").
The event time is footer ts2 (the recording stop); BW's displayed Date/Time is
the trigger = ts2 - record duration.

Root cause proven against the BE12844 oracle set: 5 of 7 events decoded to the
identical 06:00:13 (the shared session start); ts2 gives distinct plausible
event times (N844LQHB ts2 = 10:33:32, BW trigger 10:33:29 = ts2 - 3.0 s rectime).

  * read_blastware_file now uses ts2 for waveforms (discriminated by which codec
    decoded the body, not the filename — save_imported_bw passes a tmp name).
    Histograms keep ts1 (the ~24 h window start, which IS the event time).
  * Binary-only decode can't get the exact trigger: the STRT record-time byte is
    a misparsed record-type marker (0x46=70), so ts2 (the stop, ~record duration
    after the trigger) is the best estimate. A paired BW report carries the exact
    trigger — apply_report_to_event now overlays event.timestamp from
    report.event_datetime, matching the existing build-path override (line ~441).

Tests: waveform → ts2, histogram → ts1 unchanged, report → exact trigger.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-20 18:21:07 +00:00
serversdownandClaude Opus 5 ada5bc2a82 docs(changelog): Unreleased — cheap connect, Diagnostics tab, tool status
Written on dev as part of finishing the merge, per the convention adopted
2026-09-18: feature branches do not touch CHANGELOG.md, and the entry describes
what actually landed rather than what a branch intended.

First time through the new way rather than discovering the conflict afterward —
the merge was clean.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Qcu9ByJfuKBQxmrWb8rSrN
2026-09-20 17:12:49 +00:00
serversdownandClaude Opus 5 f1ab5b1e9d docs: record the 5A page-boundary bug, and assess SFM as a tool
Two things Brian asked for after the BE12599 work.

The known bug: the 5A walk discards the key's page byte, so once a unit has
recorded more than 64 KB since its last erase, an event spanning the boundary
reads an end_offset behind its own start. The chunk loop then fetches nothing
and TERM packs a negative offset_word, which is the 500. Reproduced on BE12599.
It hid this long because every capture the walk was verified against came from
a freshly-erased BE11529 — all three confirmed TERM examples sit inside page
0x11. Prod is unaffected; it ingests complete files and never runs this walk.

The status doc exists because "is SFM reliable?" has three different answers
depending on which tier is meant. The codec library and the data side are
production — verified per-sample at scale, carrying Terra-View daily. The
device side is emergency-grade: it works, but it is synchronous,
unauthenticated, and thinly tested. The lab is research artifacts. Most
confusion comes from answering for the wrong tier.

It covers all three of what Brian asked for: maturity per capability, an
operator-facing "what to use when" (the cheap probes are cheap and the event
walk is not), the known-issues table, and the gap analysis. That gap is mostly
auth, async and guardrails — not protocol work. The protocol is the finished
part.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Qcu9ByJfuKBQxmrWb8rSrN
2026-09-20 01:30:14 +00:00
serversdownandClaude Opus 5 6589da445b feat(webapp): cheap connect, opt-in event walk, and a Diagnostics tab
Connecting to a unit fired /device/events automatically, which walks the whole
event chain — every event header over a cellular link. On BE12599 that took
minutes and then 500'd outright, because its buffer has wrapped past 0xFFFF and
the uint16 offset arithmetic goes negative. Wanting to know whether ACH was on
should not require reading every event the unit has stored.

Connect now uses only cheap probes: /device/info (which already carries the
compliance config the event walk was re-reading) plus /device/events/storage_
range. The chain walk moves behind a "Load events" button in the Events
toolbar, and the Device tab gains an Event Chain card showing the first/last
keys.

Adds a Diagnostics tab for the endpoints that previously existed only as curl:
storage_range and events/index alongside monitor/status, then stop monitoring,
disable ACH (rescue?erase=false, so events survive), and erase. The wedged-unit
ladder — slow drip and blind stop — sits under its own heading pointing at the
runbook, with the reminder that slow_drip's success signal is bytes_received>0
and not a clean duration.

Erase is guarded by typing the unit's serial. Auth answers who, not whether you
meant it, and Swagger's try-it-out button on /device/events/erase is live on
:8200/docs — the realistic risk here is an accident.

Lifetime events is displayed but labelled unreliable: SUB 0x08 reports 0 on
units with years of history, which is a decode bug we have not chased yet.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Qcu9ByJfuKBQxmrWb8rSrN
2026-09-19 22:05:55 +00:00
serversdownandClaude Opus 5 0b58415fe2 chore(release): v0.31.0 — report parity + the inverted rescue
Cuts Unreleased to v0.31.0 and writes the theme now that the whole release is
visible, per the convention adopted today.

Two threads landed. Blastware Event/FFT-Report parity — the FFT, the USBM
RI8507 compliance chart, and the sensor self-check decoded for both series and
standardized into the .h5 (schema v2, /sensor_check). And the ach_server rescue
flags out of the BE12599 field emergency, which invert the wedged-unit recovery:
answer the unit's call instead of racing a Stop into the gaps between its
dial-outs.

Version stamped in pyproject.toml, CLAUDE.md and README.md. TOOL_VERSION was
already at 0.31.0 — it came in with the sensor-check work, and it is what makes
the backfill pick up the new /sensor_check group without --force.

⚠ This release owes prod a backfill: .h5 schema v1 -> v2, ~2 h on the NAS.
Stated in the Migration block.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Qcu9ByJfuKBQxmrWb8rSrN
2026-09-18 20:40:48 +00:00
serversdownandClaude Opus 5 fa22bb9f59 Merge feat/sensor-check-h5 into dev
Sensor self-check standardized into the .h5 (schema v2, /sensor_check group),
decoded for both series-3 and series-4, plus the Thor backfill script.

CHANGELOG resolved per the convention adopted today: the incoming Unreleased
preamble was dropped rather than reconciled — no preamble under Unreleased, the
theme gets written at release time — and its load-bearing half was folded into
### Migration, which said "None" and is now false.

That block now states the real cost: .h5 schema v1 -> v2, TOOL_VERSION 0.31.0
so the standard backfill picks the traces up with no --force, and ~2 h on the
NAS. The FFT, the compliance chart and the ach_server rescue flags still owe
nothing.

The branch's rewritten "Sensor self-check — both series" entry merged cleanly
and is kept.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Qcu9ByJfuKBQxmrWb8rSrN
2026-09-18 20:16:13 +00:00
serversdown 27e9c56393 Merge pull request 'Feat/ach rescue on connect' (#38) from feat/ach-rescue-on-connect into dev
Reviewed-on: #38
2026-09-18 15:26:18 -04:00
serversdownandClaude Opus 5 0408c37866 docs: write the changelog on dev, not on feature branches
Reverses the "entry goes in with the work" rule from two commits ago. That was
wrong on the evidence: of the docs(changelog) commits in history, 3 of 4 in
seismo-relay and 2 of 4 in Terra-View were made directly on dev. The rule was
generalized from one unrepresentative commit rather than from the pattern.

It also caused the exact problem it was supposed to avoid. With four worktrees
in flight, every branch edits the same few lines at the top of CHANGELOG.md;
feat/ach-rescue-on-connect and feat/sensor-check-h5 collide on that file and
nothing else. Writing the entry once, on dev, after the merge removes the
whole conflict class.

The second benefit is accuracy: an entry written after the merge describes
what actually landed, including anything that changed during conflict
resolution. The sensor-check branch is a live example — its Unreleased
preamble describes a release that no longer looks like that.

The failure mode of writing it later is forgetting, so the merge is explicitly
not finished until Unreleased is updated — same sitting, reconstructed from the
branch commit messages.

Unchanged: no preamble under Unreleased, the mandatory operational consequence,
and cutting the version on dev when ready to ship to main.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Qcu9ByJfuKBQxmrWb8rSrN
2026-09-18 18:52:17 +00:00
serversdownandClaude Opus 5 a42e8d3651 docs: make the release cadence explicit
Brian described the practice: Unreleased is the staging area for what is going
into the next release, and the version bump happens when enough has
accumulated to be worth shipping — not per commit, not per merge. The
convention already implied it ("never touch the changelog at a merge
boundary") but never said it outright.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Qcu9ByJfuKBQxmrWb8rSrN
2026-09-18 18:04:54 +00:00
serversdownandClaude Opus 5 2fabf84d4d docs: adopt a changelog convention, and make Unreleased follow it
Brian asked what the standard is; there wasn't a written one, only a de facto
pattern in the history. This writes it down in CLAUDE.md and fixes the one
place the repo already diverged from it.

The rule: write the entry in the same commit as the work, under ## Unreleased;
cut the version on dev in a dedicated chore(release) commit; never touch the
changelog at a merge boundary. The entry goes in with the change because that
is the only moment you still know why.

Two additions beyond what the history already did:

No preamble under ## Unreleased. The themed opening paragraph gets written at
release time, when the whole release is visible and can be named honestly. The
current one proved the point — "Blastware Event/FFT-Report parity: the FFT,
the USBM compliance chart, and the sensor self-check" was accurate when the
first item landed and stopped being accurate once rescue-on-connect landed
under the same heading. Removed here; the release commit writes a new one
covering everything actually in the release.

And the operational consequence is now mandatory on any entry touching the
codec, the waveform store, or the DB — including when it is "none". This
repo's changelog is how future-you learns whether a deploy costs two hours on
the NAS, so silence is ambiguous and "none" is information. The old preamble's
load-bearing half is preserved as an explicit ### Migration block rather than
dropped with the prose around it.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Qcu9ByJfuKBQxmrWb8rSrN
2026-09-18 17:39:56 +00:00
serversdownandClaude Opus 5 402bf30e37 docs(runbook): reframe as one disease with two cures, intercept first
The previous commit called BE12599 a second failure mode and claimed the
device "never enters S3 mode at all" and that no inbound work could reach it.
That was an overclaim built on a single slow_drip attempt, and Brian was right
to push back.

It is the same disease.  Method B's step 1 worked fine on BE12599 — clearing
the Destination did stop the dial-outs.  It was step 2 that did not land, on
one attempt, run ~90 s after a modem reboot with a dead session visible in the
log in that same window; BE9558H needed hours of attempts before one landed.
And the AT-init loop the ALEOS log revealed is almost certainly what BE9558H
was doing too — we just never turned on serial debug in May to look.  The
device speaks S3 fine; it handshook cleanly the moment it had a session.

What is genuinely new is the cure, and it deserves to be the default rather
than a footnote.  Racing a Stop into the gaps between dial-outs is a coin
flip.  Intercepting is deterministic: the unit dials every ~75 s, so give it
somewhere to dial and answer it.  It will not answer us because it is on the
phone — so be the one it calls.

Restructures accordingly: a "two cures" table up top, the intercept promoted
to Method A with its own procedure (listener before modem, stop at step 1.5,
drain before disabling ACH, restore the Destination and confirm it), and the
original inbound procedure kept intact as Method B for when there is no
listener the modem can reach.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Qcu9ByJfuKBQxmrWb8rSrN
2026-09-17 06:10:03 +00:00
serversdownandClaude Opus 5 c6fc3d0241 docs: BE12599 incident — the inverted rescue, plus a rescue-listener plan
The wedged_unit_recovery runbook covered exactly one failure mode.  BE12599
turned out to be a second one wearing the same symptoms, and the existing
procedure did not work on it.

Adds a "TWO failure modes" table up front so the next incident branches
correctly, and a full second-incident section covering what the ALEOS serial
debug log revealed: the device repeating a 29-byte AT modem-init string
(ATQ1/ATE0/ATS0=2, no ATD) every 75 s, never getting an OK because the modem
is in TCP data mode, and therefore never entering S3 mode at all.  Inbound
cannot win against that, no matter how well framed.

Also records the two red herrings, since together they cost ~90 minutes:
the RV50 trusted-IP whitelist drops non-listed sources silently (presents as
a connect timeout, and Brian's dynamic dev IP had rotated off the list), and
sfm/server.py returns 502 for BOTH "Protocol error:" and "Connection error:",
so a 502 was misread as "TCP connected, device mute" and a theory built on it.

And the gotchas worth never re-deriving: slow_drip's send_error=null plus a
full duration is not success (only bytes_received > 0 is); stopping monitoring
removes the call-in trigger, so it costs you the channel; --events-only skips
the device-info step, so the serial is never read and ach_state keys on
peer:ephemeral_port, silently breaking dedup and re-downloading the same event
every session.

The plan doc captures the tool Brian wants built out of this — a rescue
listener with a real lifecycle and, critically, a confirmation gate before
shutdown, because leaving the modem's Destination pointed at a dead listener
is worse than never having started.  Open questions are listed rather than
guessed at.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Qcu9ByJfuKBQxmrWb8rSrN
2026-09-17 05:45:26 +00:00
serversdownandClaude Opus 5 9f1050b5e7 feat(ach): rescue-on-connect — stop monitoring / disable ACH from the server side
A unit whose geophone offset has grown past its trigger level records
back-to-back and, with ACH set to "after event recorded", re-dials every
time.  The wedged_unit_recovery runbook handles that by reaching the unit
inbound and clearing the modem's Destination Address so it stops dialing.

That fails when the device is wedged mid-modem-init.  BE12599 (2026-09-16)
sat repeating a 29-byte AT setup string — ATQ1/ATE0/ATS0=2, no ATD — every
75 s.  The modem is in TCP data mode, never interprets it, never answers OK,
so the device never progresses into S3 mode and ignores every frame we send.
Worse, each attempt makes ALEOS log "tcpmode trying to send to invalid
socket" and re-run "Initialize Auto answer on port 9034", which orphans any
held inbound session — slow_drip reports a clean 120 s hold with
bytes_received=0 because the modem stopped bridging after the first re-init.

Inbound cannot win that race.  But the modem auto-dials its Destination
whenever serial data arrives while closed, so pointing Destination at an
ach_server turns those 75 s attempts into a device-initiated session that
the modem bridges correctly.

Adds --stop-monitoring, --disable-ach and --rescue.  They run as step 1.5,
after the handshake and before the event walk, each independently guarded so
a failure does not abort the download.  Outcome is written to rescue.json.
Startup banner reports both, and warns when --restart-monitoring would undo
--stop-monitoring.

Prefer --stop-monitoring alone on first contact: --disable-ach stops the unit
calling, which is the only channel to a unit in this state, and halting the
recording ends the loop on its own.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Qcu9ByJfuKBQxmrWb8rSrN
2026-09-16 20:54:46 +00:00
serversdownandClaude Opus 4.8 8265e32ad5 feat(backfill): regenerate .h5 with /sensor_check; TOOL_VERSION 0.31.0
Complete the sensor-check standardization: existing events need their .h5
regenerated to gain the v2 /sensor_check group.

  * backfill_thor_events.py attaches the decoded series-4 traces
    (micromate.sensor_check) on its own IDF decode path, mirroring
    save_imported_idf, so regenerated Thor .h5 files get the group. Series-3
    backfill needs no change — it re-decodes via read_blastware_file, which now
    attaches the traces itself.
  * TOOL_VERSION 0.30.0 → 0.31.0 so the standard backfill regenerates every
    event (no --force): the tool now produces the /sensor_check group. Purely
    additive — no decoded value changes.
  * CHANGELOG (Unreleased): sensor-check now series-3 + series-4, standardized
    into the .h5 (schema v2), with the ⚠ backfill note; FFT + compliance stay
    no-backfill (they read existing .h5 samples).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-16 06:53:33 +00:00
serversdownandClaude Opus 4.8 8d3cdba1b5 feat(h5): standardize sensor-check into the .h5 (schema v2); SFM reads it
Make the sensor self-check a first-class part of the standardized decoded event
so SFM stops decoding it at report time — device-agnostic, per the store's
decoder→standardized-.h5→SFM model.

  * Event gains a `sensor_check` field; both decoders attach the traces where
    they set raw_samples — series-3 in event_file_io.read_blastware_file
    (minimateplus.sensor_check), series-4 in waveform_store's IDF path
    (micromate.sensor_check).  Covers ingest and backfill (both re-decode).
  * event_hdf5 bumps schema_version 1→2 and writes an optional /sensor_check
    group (raw counts, int32, per channel present).  read_event_hdf5 returns
    it; plot_json_from_hdf5 carries it as a top-level key.  Old v1 files still
    read cleanly (no group → None), so nothing breaks before the backfill.
  * gather_report_data reads sensor_check_waveforms from the .h5 and drops the
    report-time series-3 decode — the report no longer reaches into a decoder,
    and a series-4 event now lights up the same strip automatically.

Stored as raw counts (a shape diagnostic, rendered fit-to-box): the per-series
count scale differs and a physical mic unit is ill-defined, so conversion would
add complexity for no display benefit — easy to add later if a numeric use
appears.

Tests: .h5 roundtrip + backward-compat + plot_json + real series-3 decode
attaches to the Event.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-16 06:49:55 +00:00
serversdownandClaude Opus 4.8 685a17d180 feat(series4): decode sensor self-check waveforms from the IDFW binary
The Thor/Micromate (series-4) IDFW binary carries the sensor self-check in its
fixed-header region (before the waveform body), as up to four records tagged
01 0e 3c/3d/3e/3f — the SAME channel ids as series-3 (Tran/Vert/Long/MicL).
Unlike series-3's delta-coded trailing block, series-4 stores each trace as a
raw int16-BE array after an 18-byte record header (2-byte sample count at
offset +8). Three-channel (mic-disabled) units carry only 3c/3d/3e.

New micromate/sensor_check.py: decode_idf_sensor_check(raw) locates the record
chain (id-ordered marker run, so a stray body match can't chain) and reads each
trace's int16 samples → {Tran,Vert,Long[,MicL]: [counts]}, or {} when absent.

Reverse-engineered + validated against 4 UM oracle events (added as fixtures):
clean geophone ring-downs on all, mic pulse trains on the 4-channel units,
correctly no MicL on the two 3-channel units. Validated by shape + cross-event
consistency (no Thor report strip to exact-match, unlike series-3's BW reports).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-15 20:01:39 +00:00
serversdownandClaude Opus 4.8 dcd9ad6f48 Merge feat/fft-series3: Blastware FFT, USBM compliance chart, sensor self-check
Reverse-engineered Blastware Event/FFT-Report parity, all additive (reads the
existing .h5 samples + retained raw binary, no DB/.h5 change or backfill):
 - Blastware-compatible channel FFT (waveform_fft)
 - USBM RI8507/OSMRE compliance chart on the event-report PDF (sfm/compliance)
 - sensor self-check strip decoded from the series-3 binary trailing block
   (minimateplus/sensor_check) + Frequency/Overswing sub-rows
 - seismo_lab Inspector hex reader (minimateplus/binary_annotate)
 - report fixes: stacked-lane y-tick collision, header serial fit

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-15 14:37:44 +00:00
serversdownandClaude Opus 4.8 4f73e919a0 docs(changelog): Unreleased — FFT, USBM compliance chart, sensor self-check
Document the feat/fft-series3 work under Unreleased: Blastware-compatible
channel FFT, the USBM RI8507/OSMRE compliance chart on the event-report PDF,
the decoded sensor self-check strip + Frequency/Overswing sub-rows, and the
seismo_lab Inspector hex reader — plus the two report-panel fixes (tick
collision, header serial fit). Additive, no .h5/DB change or backfill.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-15 14:34:04 +00:00
serversdownandClaude Opus 4.8 2a747f6893 fix(report): attach sensor-check strip to the waveform panel; move "0.0"
Match Blastware's layout, measured off the reference PDF: the sensor-check
strip shares a border with the main waveform panel (no gap between them), and
the per-lane "0.0" baseline labels sit to the RIGHT of the strip. Previously
the strip floated with a gap and the "0.0" label overprinted the strip's left
edge. Purely layout — the traces and decode are unchanged.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-15 05:48:31 +00:00
serversdownandClaude Opus 4.8 2c5c20cfd7 fix(report): fit sensor-check mini-plots to their boxes
The sensor-check strip used a symmetric ±max scale, so the one-sided geophone
ring-downs (a dip to ~-990 with the baseline at 0) sat in the bottom half of
each mini-box with the top half blank — visibly off next to Blastware. Scale
each mini-plot to its actual data range with a small pad instead, and draw a
faint zero baseline, so the ring-downs and the mic pulse train fill their boxes
the way BW draws them.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-15 05:39:53 +00:00
serversdownandClaude Opus 4.8 ab9d84fde6 feat(report): render the sensor-check strip + report polish
Wire the decoded sensor self-check waveforms (previous commit) onto the event
report PDF, and fold in two related waveform-panel cleanups.

Sensor-check strip (matches Blastware):
  * ReportData gains sensor_check_waveforms; gather_report_data decodes it from
    the retained raw BW binary (store.paths_for) at report time — no ingest or
    .h5 change, waveform events only.
  * _draw_waveform_subplot now draws a narrow right-hand strip of per-channel
    mini-plots (MicL pulse train + Long/Vert/Tran ring-downs) aligned to the
    lanes, captioned "Sensor Check".
  * stats table gains the "Frequency" / "Overswing Ratio" sub-rows under Sensor
    Check (7.5/7.7/7.3 Hz, 3.6/3.3/3.7), formatted to 1 decimal like BW; values
    come from the already-parsed sensor_check scalars.

Cleanups (pre-existing, in the same panel):
  * fix the stacked-lane y-tick collision — adjacent lanes' -1.0 / 1.0 labels
    overprinted at the shared boundary; prune the extreme ticks (MaxNLocator
    prune="both") so each lane shows clean interior ticks only.
  * fix the header serial+firmware line running off the right page edge —
    tighter right-column indent + BW's slightly smaller 7.5pt header.

Tests: sensor-check + compliance + geo-scale + fft all green (15). The
test_bw_ascii_report failures are pre-existing (gitignored decode-re fixtures
absent in this worktree), unrelated to this change.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-15 05:33:38 +00:00
serversdownandClaude Opus 4.8 6341432524 feat(series3): decode sensor self-check waveforms from the binary
The Blastware Event Report draws a "Sensor Check" strip on the right of the
waveform panel — the little traces the unit records when it pulses each sensor
before monitoring. Those live in the series-3 binary's trailing block, after
the main waveform record-chain and the per-channel calibration records, as four
length-prefixed records tagged 0x3c-0x3f (Tran/Vert/Long geophone ring-downs +
MicL pulse train). Reverse-engineered against 7 BE12844 oracle events.

New minimateplus/sensor_check.py: decode_sensor_check(raw) locates the record
chain (validated by walking the ids 0x3c->0x3f via their length prefixes) and
decodes each record's delta stream (payload[20:len-8]) with the same 10/20/30/00
delta-block tags as the main waveform codec, from an anchor of 0. Returns
{Tran,Vert,Long,MicL: [samples]} in raw 16-count units, or {} when absent.

Validated: mic pulse-train zero-crossing frequency = 20.1 Hz (exact match to
BW's mic Channel Test freq); geophone ring-downs are consistent ~-990 raw
deflections that damp to a ~-310 settle across all 7 events (a fixed
calibration pulse, so near-identical every run).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-15 05:26:28 +00:00
serversdownandClaude Opus 4.8 dc74c97ade feat(report): size the USBM compliance chart to match Blastware
The compliance chart on the event-report PDF was correctly drawn but far
too small ("it's tiny") — a ~2.6in square dropped between the mic and
stats rows.  Resize + reposition it to match Blastware's Event Report,
measured directly off a BW reference PDF (n844lqhbzt0w) rasterized with
fitz: the chart data box now spans figure fractions x[0.489,0.951]
y[0.502,0.867] — a ~3.9in square running from just under the header down
through the stats band, hard against the right page margin, exactly as BW
draws it.  Title updated to BW's "USBM RI8507 And OSMRE".

To clear room for the BW-sized chart (waveform layout only):
  * _draw_stats_table gains bbox_width/col_widths/fontsize params; the
    waveform layout packs the Tran/Vert/Long table into the left ~0.42 so
    its columns no longer sit under the chart.  Histogram layout keeps the
    wider defaults (byte-identical output; it has no compliance chart).
  * the mic block's long "Channel Test Passed (Freq … Amp … mv)" line gets
    a tighter indent + one-point-smaller font so it ends before the chart's
    left edge instead of running behind it (_kv gains a fontsize param).
  * the Peak Vector Sum line left-aligns under the compacted table (one pt
    smaller) so it clears the chart's bottom-left tick labels.

Chart placement centralized in the _COMPLIANCE_BOX constant. No change to
the compliance math, the scatter, or the histogram report.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-14 22:56:44 +00:00
serversdownandClaude Opus 4.8 95f926c318 feat(report): enlarge the compliance chart to a full upper-right panel
The chart was cramped into the short mic band (~2in) and rendered tiny. Move it
to its own large square panel (_draw_compliance_panel) spanning the mic + stats
rows on the right, clear of the stats columns — matching Blastware's Event
Report proportions. _draw_mic_and_usbm now draws only the mic block.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-14 20:33:09 +00:00
serversdownandClaude Opus 4.8 6ad4fd73dd fix(compliance): square plot box (set_box_aspect) so the chart isn't squashed
The compliance chart sits in the short, wide mic-and-USBM band on the event
report; without a fixed aspect matplotlib stretched it wide-and-short. Force a
square plot box, which is how log-log compliance charts are conventionally drawn.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-14 20:21:17 +00:00
serversdownandClaude Opus 4.8 db818f716c feat(report): draw the USBM RI8507 compliance chart on the event report
Replace the "[compliance chart coming soon]" placeholder in
_draw_mic_and_usbm with a real inset axes calling
sfm.compliance.draw_compliance_chart on rd.channels / rd.sample_rate_sps
(the full-rate in/s waveform samples). Title updated "USBM RI8507 And OSMRE"
→ "USBM RI8507" — we draw only the RI8507 lines (Drywall 0.75 + plaster 0.50);
the OSMRE overlay is dropped by choice.

Waveform events only (the histogram layout has no USBM chart). Falls back to a
"(no waveform data)" note when samples are unavailable. Closes the 1.0
compliance-chart blocker.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-14 20:18:29 +00:00
serversdownandClaude Opus 4.8 dad35e47fe feat(compliance): USBM RI8507/OSMRE compliance chart + reference doc
sfm/compliance.py renders the velocity-vs-frequency blasting compliance chart
Blastware draws on its Event Report:
- limit_at()/limit_curve() — the RI8507 Fig B-1 / 30 CFR 816.67 curve as data
  (Drywall 0.75 + plaster 0.50 lines): 0.030in low-freq bound, plateau, 0.008in
  rising diagonal to a 2.0 in/s cap at ~40 Hz, drawn continuous.
- channel_compliance_points() — the per-cycle (freq, peak-velocity) scatter by
  the zero-crossing method (matches Blastware; cloud ceiling = channel PPV).
- draw_compliance_chart() — matplotlib rendering (both lines + scatter, BW tick
  scales + channel markers).

Verified against 7 BE12844 Blastware reports. docs/ri8507_compliance_curve.md
captures the curve construction, the SHM basis, and the scatter method.

Not yet wired into report_pdf.py — that placeholder is the next step.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-14 18:34:18 +00:00
serversdownandClaude Opus 4.8 2902ab373e feat(fft): Blastware-compatible channel FFT (waveform_fft)
channel_spectrum(samples, sps) → the single-sided amplitude spectrum Blastware's
FFT Report draws, and dominant_frequency() picks its peak in the 2–250 Hz band.

Reverse-engineered against 7 BE12844 (MiniMate Plus) events with Blastware FFT
reports as ground truth. Recipe: DC-remove, NO window (a window smears the peak
and worsens the match), zero-pad to 4096 (→ 0.25 Hz bins at 1024 sps — the
resolution every reported dominant frequency lands on), single-sided 2/N
amplitude. Reproduces Blastware's dominant frequency to the exact bin on all
28 channels and the amplitude to report precision.

This is the missing piece for both the USBM RI8507 compliance chart (its scatter
is these (freq, amp) points vs the limit curve) and the FFT view.

Pure numpy, series-agnostic (feed it in/s samples from either decoder). The 7
events land in tests/fixtures as the oracle (force-added past the fixtures
gitignore, matching 5-11-26 / decode-re-5-8-26).

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-14 17:15:16 +00:00
serversdownandClaude Opus 4.8 11e3e515f3 feat(seismo_lab): Inspector tab — annotated hex reader for Series-3 binaries
New top-level "Inspector" tab: open any Series-3 waveform binary and read it as
a colour-coded hex dump driven by binary_annotate. Each region is labelled with
its offset range and size (header / STRT / per-channel sample records / footer),
and everything the decoder can't account for is painted UNKNOWN (red) so gaps
stand out — the point being to comb for undecoded data (e.g. a stored FFT/
spectral block). A summary shows total size, region count, and % unknown.

Read-only reader/translator; Series-3 only for now (Series-4 later). The GUI
needs tkinter + a display (not available in the dev venv); the annotator core it
calls is unit-tested headless.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-12 05:27:43 +00:00
serversdownandClaude Opus 4.8 845ec38f96 feat(inspector): Series-3 binary structural annotator (binary_annotate)
annotate_blastware_binary(raw) → a gap-free tiling of labelled Spans
(header / STRT / per-channel sample records / footer / unknown) for a hex
viewer to paint. Every byte is covered; anything the decoder can't account
for is a first-class `unknown` span, so undecoded regions stand out.

Composes the existing waveform_codec.walk_records over the body between the
STRT record and the 26-byte footer. On the cracking fixtures this already
surfaces a ~1700-byte undecoded trailing region (stream-end marker + serial +
…) per file — a candidate home for stored spectral/FFT data.

TDD: tests assert the spans tile the whole file, STRT is located, the geo
sample records are labelled, and the footer is last.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-12 05:27:43 +00:00
serversdownandClaude Opus 5 88c0e2b765 chore(release): v0.30.0 — series-4 correctness
Bumps package version, README banner, CLAUDE.md header and TOOL_VERSION to
0.30.0, and cuts the CHANGELOG entry for the Thor / Micromate decoder work.

Also documents the previously-unreleased event-report PDF fix (91b9b45),
which had landed on dev without a CHANGELOG entry.

TOOL_VERSION is bumped so refreshed sidecars carry the new codec version and
a future fix gates regeneration correctly. Note it was NOT required to
unblock this backfill: all 4,529 prod series-4 sidecars sit at 0.18.0-0.23.0,
well under the previous 0.29.0, so they were never being skipped. Verified by
dry-running scripts/backfill_thor_events.py against a copy of the prod store
(refreshed=379, skipped=0) both before and after the bump.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-12 04:58:07 +00:00
serversdownandClaude Opus 5 904522a9c5 fix(codec): 40 NN int16 blocks are not capped at NN=8
data_block_len() rejected any `40 NN` block with NN > 0x08. That guard had
no evidence behind it: every corpus available when it was written used only
NN in {1,2,3,4,8}, so it was never exercised. Loud UM12947 events use NN of
12, 16, 20 ... up to 196.

Because walk_body/run stop at the first unrecognised tag rather than
raising, rejecting those blocks surfaced as silently short channels -- e.g.
Tran 1812 / Vert 2132 / Long 2324 on a file whose export carries 2324 for
all three. The real bound is the buffer; the caller additionally clamps to
the record end.

Verified against Thor's own CSV exports for UM12947 (2025-07-14 .. 09-25,
167 waveforms, supplied as CSV.zip):

  length mismatches   22 -> 0
  per-sample exact    1,476,242 / 1,476,249

These are NOT truncated recordings, which was the competing hypothesis --
the exports carry the full sample count.

tests/test_waveform_codec.py asserted the cap as intended behaviour. That
assertion encoded an assumption, not a verified fact, and is replaced with
one pinning the opposite plus the evidence.

Across all three ground-truth corpora: 459 waveform files,
3,807,158 / 3,807,165 samples exact. Production IDFW is now 575/575 with
zero truncations and zero decode failures (median PPV error -0.0007% across
8 units). Series-3 re-verified unchanged at 14,338/14,338.

The 7 residual samples each differ by one 4th-decimal tick and are Thor's
own rounding: intersecting the per-sample rounding constraints over that
corpus is infeasible (binding pair contradict by 2.3e-11, 7e-5 relative),
so no single linear LSB reproduces every printed value. _GEO_LSB_IPS is
already pinned to ~1e-11; do not retune it to chase these.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-11 05:05:46 +00:00
serversdownandClaude Opus 5 c07aaa552c fix(series4): support mic-disabled (3-channel) Thor units
Verified against a second Thor corpus (9-10-26-csv-req: UM11402, UM12947,
UM20147) with per-sample CSV exports: 139/139 waveforms exact
(1,273,380/1,273,380 samples) and 877/877 histograms within 2% of Thor's
reported PPV -- up from 66.9% and 56.6%.

Some units run with the microphone disabled, which changes two structural
things that were both hardcoded to the 4-channel shape:

- Waveform body head sat below the scan floor. A 3-channel unit has a
  shorter fixed header and puts its record chain head at 0x0dba, under the
  old _BODY_SCAN_FLOOR of 0x0E00. The scan could not see it and fell
  through to the Vert segment-0 record, decoding a body shifted one
  position around the channel rotation -- Vert came up exactly 512 samples
  short. Floor lowered to 0x0C00. The body-offset scoring also had to stop
  requiring four channels, or `equal` is permanently False for these events
  and the pick falls back to raw sample count.

- Histogram interval record is 56 bytes, not 72. It is
  16 * n_channels + 8, and is not inferable from the segment length alone.
  The interval count now comes from the segment's cumulative counter
  (n = counter - prev_counter) and the stride is derived from it. Assuming
  72 read 7 intervals out of every 10-interval segment, then walked off
  alignment into garbage that decoded as ~10 in/s peaks -- inflating some
  files' PPV by up to 191,000%. Also recovers 4 files that previously
  decoded no intervals at all.

Combined across both corpora: 292/292 waveform files,
2,330,916/2,330,916 samples exact. Production IDFW truncations 41 -> 22.
Series-3 unaffected (no shared-codec change in this commit; last full run
14,338/14,338).

Known open, diagnosed but NOT verified: the remaining 22 unequal + 1 failing
production IDFW files (all UM12947, 2025-07-14..09-23) stop the block walker
on tag 40 0c. data_block_len() caps the 40 NN int16 block at NN > 0x08 while
those files use NN up to 196. Both verified corpora only ever use
NN in {1,2,3,4,8}, so the cap is untested there and lifting it leaves both at
100.000% -- which is not evidence it decodes these correctly. Deliberately
not shipped; needs Thor CSV exports for UM12947 in that date range.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-10 20:00:56 +00:00
serversdownandClaude Opus 5 726c2ce1b5 fix(series4): Thor/Micromate decoder is now per-sample exact
Verified against Thor's own CSV exports, which carry a per-sample
four-column block beside every binary (CSV/<name>.IDFW.csv). Those 1,012
paired files were in the corpus all along; the decoder had been pinned to
a superseded walker on the stated grounds that "Thor has no ASCII ground
truth in the corpus and its geo scaling is separately suspect". Both
premises were false.

  IDFW per-sample exact      39.1%  -> 100.000% (1,057,536/1,057,536)
  IDFW files fully exact     0/153  -> 153/153
  IDFW PPV median error      -3.32% -> -0.002%
  IDFH within 2% of Thor PPV 51.1%  -> 100.0% (858/858)
  prod IDFW, 8 units         -3.3%  -> -0.001%

Four independent root causes:

- Geo LSB was 0.0003, the 4-dp *display rounding* of the real
  0.000310308 mistaken for the LSB, so every series-4 geophone sample
  read 3.3% low. Pinned to +-6e-11 by intersecting 991,415 rounding
  constraints; corroborated by the +-full-scale seed (+-32226) left in
  unwritten IDFH slots. IDFH had a separate, also wrong, 10.0/32768.

- IDFH histograms were capped at 250 intervals: the segment validator
  required the interval counter's high byte to be zero, but the counter
  is a uint16 cumulative index, so every segment past interval 255 was
  rejected. Runs over ~4 hours lost their tail, often the peak.
  540/858 corpus files affected.

- Record mode 00 00 (raw int16, 10-byte header) was unhandled and fell
  through the dispatch, silently dropping each channel's first 512
  samples -- the long-standing "loud events truncate" symptom.
  MODE_ABSOLUTE is now also accepted as a segment-0 preamble.

- The body-offset search matched 00 02 00 *inside* record headers,
  selecting a candidate part-way down the chain and decoding a
  rotation-shifted body. It now anchors on record headers and takes the
  chain head (6 ms/file).

Also fixes the separately tracked "UM-series decodes ~1000x low" bug.
Series-3 re-verified unchanged at 14,338/14,338 exact after the shared
waveform_codec change.

Known open: 41/575 prod IDFW files (7%, mostly UM12947/UM20147) decode
with unequal channel lengths and also fail metadata extraction -- a
different header variant with no Thor export in the store.

NOTE: this is a codec change; the Thor store owes a regeneration via
scripts/backfill_thor_events.py.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01Ru8Lg9HkkYvX9VWWo65SmL
2026-09-10 18:06:14 +00:00
serversdownandClaude Opus 4.8 91b9b4578c fix(pdf): shared geo Y scale across Long/Vert/Tran (was per-trace)
The event-report waveform plot scaled each geo lane to its own peak, so a small
channel filled its lane looking as big as a large one — and the "Geo: X in/s/div"
footer only reflected whichever channel was checked first, so its div value was
wrong for the other two. Now all three geo lanes share ONE symmetric scale =
max |sample| across them (padded, 0.05 in/s floor), matching the event modal and
BW's single amp/div; the footer reflects that shared scale. Mic keeps its own psi
scale. Big events are unchanged (e.g. BE12844 stays 0.185 in/s/div).

Test-first: tests/test_report_pdf_geo_scale.py (shared scale + floor), 2 tests.

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01YDXjZCr4RqT2U3QvMDhgzf
2026-09-07 23:26:42 +00:00
184 changed files with 38797 additions and 1227 deletions

No files matched your search

+43 -33
View File
@@ -1,33 +1,43 @@
/bridges/captures/
/example-events/
/tests/fixtures/
/manuals/
# Python build artifacts
*.egg-info/
dist/
build/
# Python bytecode
__pycache__/
*.py[cod]
# Virtual environments
.venv/
venv/
env/
# Editor / OS
.vscode/
*.swp
.DS_Store
Thumbs.db
# Analyzer outputs
*.report
claude_export_*.md
# Frame database
*.db
*.db-wal
*.db-shm
/bridges/captures/
# Capture artefacts that land beside the bridge scripts. Deliberately NOT
# `/bridges/s3-bridge/` -- proxy.py and s3_bridge.py live there and are tracked.
/bridges/*.bin
/bridges/s3-bridge/*.bin
/bridges/s3-bridge/*.log
/bridges/s3-bridge/*.set
/example-events/
/tests/fixtures/
/manuals/
# Python build artifacts
*.egg-info/
dist/
build/
# Python bytecode
__pycache__/
*.py[cod]
# Virtual environments
.venv/
venv/
env/
# Editor / OS
.vscode/
*.swp
.DS_Store
Thumbs.db
# Analyzer outputs
*.report
claude_export_*.md
# Frame database
*.db
*.db-wal
*.db-shm
# Config-block snapshots from scratch/mm_config_diff.py (device dumps, not source)
scratch/mm_config_snaps/
+744
View File
@@ -4,6 +4,750 @@ All notable changes to seismo-relay are documented here.
---
## Unreleased
### Fixed
- **Waveform event times were the monitoring-session start, not the trigger
(~hours off).** `read_blastware_file` stamped events with footer `ts1`, which
for a waveform is the session start a unit shares across every event that day
(a unit arming at 06:00 stamped 06:00 on all of them — the modal and PDF both
showed it, since it's the stored value). The event time is footer `ts2` (the
recording stop), and Blastware's trigger = `ts2 - record time`. The record
time is a big-endian float32 in the recording-setup config block (30 bytes
before the `Standard Recording Setup` marker), so the **exact trigger is now
recovered from the binary alone** — all 7 BE12844 oracle events decode to
their exact Blastware time (e.g. N844LQHB 10:33:29), no paired `.TXT` needed.
Histograms keep `ts1` (the ~24 h window start). A paired report's
`event_datetime` stays authoritative (unit-clock drift).
⚠ **Needs a re-decode backfill** to correct existing stored events' timestamps.
- **`scratch/mm_frame_parse.py` accepted either checksum rule, so it could not
falsify either.** It tried plain SUM8 *and* a DLE-aware variant and reported
whichever matched, which is why it never flagged a bad frame and why the
protocol reference carried the wrong rule for two days — "zero bad checksums
across three sessions" was true and carried no information. It now validates
against SUM8 alone and names the DLE-aware result only as a near-miss, never as
a pass. Still zero bad frames across all captures, strictly tighter.
- **A 64 KB download cap, one event away from biting.** The `0x5A` chunk offset
was written as a **uint16** at `params[2:4]`, because every offset THOR was
observed to send fits in two bytes (largest `0x3400` = 13,312) — which capped a
download at 65,536 B. UM20147 holds a **72,560-byte** event, so that cap was
not hypothetical: the event could not have been fetched at all.
`params[0:4]` is demonstrably one 4-byte field (chunk 0 puts the 4-byte event
key there), so writing the offset as a uint32 BE is **byte-identical below
65,536** — the replay test still matches all 74 of THOR's frames — and reaches
past it. ✅ Confirmed on the unit: **71 chunks, exact size.**
⚠ **This is the Series III 64 KB page-boundary bug wearing a different hat**,
and that one is *still open* — `parse_strt_end_offset()` discards the key's page
byte and the `5A` walk crashes once a unit's buffer crosses 64 KB. The
transferable lesson: *an address field whose high bytes are zero in every
capture is not a narrow field, it is an untested one.* Same mistake, found
twice, in code written years apart.
- **The probe's own control was circular.** `scratch/mm_stream_probe.py` compared
each candidate request size against a reference download that used the library
*default* chunk size — which the same change had just raised to 16,384. A fault
at 16 KB would have been shared by the control and every comparison would have
passed. Pinned to `THOR_CHUNK_SIZE`, the only size with THOR's captures behind
it.
- **`mm_client_check.py` reported THOR's request count, not its own.** It printed
"71 chunks" for a download that made **5 requests**, computing `size / 1024`
while the download used the 16 KB default — nearly reading a working 16 KB
download as a broken 1 KB one. A diagnostic that misreports what it did is
worse than one that says nothing.
- **The ACH server buffered its own output and mislabelled modem chatter.**
stdout was block-buffered, so the log read **empty** while a call was in
progress — useless for a tool whose job is being watched during a one-shot
event. It also left `RADIO RING` as a hex dump; it now names known modem
strings and, on rings without a `CONNECT`, says what to check. And its
docstring promised scanners leave no trace on disk while the failure path
created a session directory regardless.
- **`.gitignore` missed capture artefacts beside the bridge scripts.** Targets
`*.bin`/`*.log`/`*.set` specifically — **not** `/bridges/s3-bridge/`, which
holds tracked source.
- **The Series-4 config watcher overwrote the previous session's snapshots.**
`scratch/mm_config_diff.py watch` saved every run as `watch-000…NNN`, so each
session silently replaced the last -- harmless while they were clock ticks,
data loss once they were findings. Labels are now `watch-MMDD-HHMM-NNN`.
- **`mm_client_check.py` carried two stale labels.** It still printed `0x06`
content[4:8] as "unexplained" (it is very likely the monitor-log count -- see
*Changed*) and announced UM20147 as "the FIRST 11.0BD unit this code has met".
### Added
- **Diagnostics tab in the SFM standalone webapp.** Surfaces the device
endpoints that previously existed only as `curl`: `events/storage_range` and
`events/index` alongside `monitor/status`, then stop monitoring, disable ACH
(`rescue?erase=false`, so stored events survive), and erase. The wedged-unit
ladder — slow drip and blind stop — sits under its own heading pointing at
`docs/runbooks/wedged_unit_recovery.md`, with the reminder that `slow_drip`'s
success signal is `bytes_received > 0` and not a clean duration. Erase is
guarded by typing the unit's serial: auth answers *who*, not *did you mean
it*, and Swagger's try-it-out button on `/device/events/erase` is live on
`:8200/docs`.
- **`docs/sfm_tool_status.md`** — an honest per-capability maturity assessment:
what is production-grade (the codec library, the data side), what is
emergency-grade (the device side), what is a research artifact, the
known-issues table, and the gap to a real tool. Also records the **5A
page-boundary bug** as known: `parse_strt_end_offset()` discards the key's
page byte, so once a unit has recorded more than 64 KB since its last erase,
an event spanning the boundary reads an `end_offset` *behind* its own start —
the chunk loop fetches nothing and TERM packs a negative `offset_word`, which
500s. Reproduced on BE12599. Production is unaffected: it ingests complete
files via the watcher path and never runs this walk.
- **The Micromate (Series IV) live wire protocol, reverse-engineered end to
end** — `docs/micromate_protocol_reference.md`. Worked out against a bench
UM12947 over USB and a recording relay, with THOR driving every write so that
no command has ever been originated against a unit by this project. **A
Micromate answers Series III command frames**, with three framing differences:
responses carry no leading `DLE`, `payload[1]` is `0xC5` (Blastware firmware)
or `0x03` (Thor firmware) rather than `0x10`, and the data length is a
**uint16 BE at `payload[8:10]`** — read as a single byte it under-reads
`SUB 0x1A` by 47x. Read path, event chain, and `SUB 0x5A` streaming the
`.IDFW` file verbatim are all confirmed.
- **Series IV setup management, fully mapped.** `0x41` reads the active setup
name, `0x1A` its config block, `0xDA` names the target `.MMB`, `0x71`/`0x72`
write it back. **Setups are read-modify-write** — the written block is the
read block, 91% byte-identical at a fixed 11-byte shift. `0xDA` **creates**
files rather than only overwriting, confirmed on the unit's own screen, and an
overwrite is protocol-identical to a create: no handshake, no warning, and no
protection even over the *active* setup of a monitoring unit.
- **The scheduler file decoded** — `\system\schedule\schedule.dat`, 260-byte
records carrying an action bitmask (2 start, 4 stop, 8 self-check, 16 ACH), a
half-hour slot (48/day), day-of-week (0 = Sunday) and a length-prefixed setup
name. Verified entry-for-entry against the operator's own THOR screen.
- **A generic file transfer addressed by full path** — `0x94`/`0x48` read,
`0x8D`/`0x8E` write. This **retracts** an earlier conclusion in the same
document that no such command existed; that was inferred from absent firmware
strings and was wrong.
- **Monitoring control and per-event delete.** `0x96`/`0x97` start and stop as
on Series III, but the monitoring flag at `SUB 0x1C` `data[12]` must be tested
for **non-zero** (observed as both `0x0E` and `0x0C`) rather than compared to a
constant. Deletion is **per-event** — `0xA8` with the event key, then `0xAA` —
which is safer than Series III's erase-everything. `SUB 0x1C` also carries the
device clock.
- **`bridges/mm_probe.py`** — distinguishes the four faults THOR reports
identically as "disconnected": refused, connect timeout (the silent-drop
signature of a trusted-IP whitelist), **connected but no reply** (the modem
answered and the unit did not), and replied. Each verdict names what to try
next. `--slots N` tests single-session modem behaviour.
- **`bridges/mm_link.py`** — a bench stand-in for a cellular modem, with a
decoded timestamped log and fault injection (`blackhole`, `drop`, `delay`,
`onewaydev`) driven by a control file. No pyserial; stdlib `termios` only.
- **`scratch/mm_frame_parse.py`**, **`socat_log_split.py`** and **`fake_unit.py`**
— a Micromate-aware frame parser (`S3FrameParser` cannot see these responses at
all, since it scans for `DLE+STX`), byte-exact capture recovery from a
`socat -x` relay log, and a serial-port stand-in that answers as a unit.
- **A live client for Series IV — `micromate/{framing,protocol,client}.py`.**
`micromate/` was codec-only; it can now talk to a unit. Connect over TCP (a
cellular modem) or serial/USB, identify a unit, read its state, clock, battery,
memory and setups, walk the event chain and download events as `.IDFW`/`.IDFH`
bytes the existing codec already decodes. **98 offline tests**, every response
constant a real captured data section. `minimateplus/transport.py` is reused
as-is; `minimateplus/framing.py` deliberately is **not** — see *Changed*.
⚠ **Read-only.** Setups, schedules, call-home config, monitoring start/stop
and per-event delete are all mapped and none are implemented. No command has
ever been originated against a unit by this project; every write in the
protocol reference was performed by THOR while we recorded.
- **Verified on real hardware, both transports, both firmware lines.** Identical
wire bytes over USB CDC-ACM and an RX55 in PAD mode — 11,580 B in and 761 B out
to the byte. Every `11.0BD` inference confirmed on UM20147, including the four
extra trailing bytes in `SUB 0x1C` that make Series III's from-the-end offsets
report a battery voltage of **577.92 V**. A monitoring unit answers reads with
no `SESSION_RESET`, which Series III requires. All six bench events decode
with the existing IDF codec — 4 waveforms at 12,288/12,288/12,288/8,192 samples
and 2 histograms — so `/db/import/idf_file` ingests a directly downloaded event
unchanged.
- **`bridges/mm_client_check.py`** — drives the read client against a unit and
reports per-command timings, read counts and byte totals, so two transports or
two firmware lines can be diffed. `--capture DIR` writes a `raw_bw_*`/`raw_s3_*`
pair in the layout `scratch/mm_frame_parse.py` reads, turning a field run into
a test fixture. No pyserial — stdlib `termios`, because `pip install` is
refused outright by PEP 668 on the distros the bench hosts run.
- **The Series-4 event chain.** `MicromateEventRef` plus `list_events()`,
`iter_events()`, `download_event()`, `get_event()` and `decode_error()` on
`MicromateClient`. Walk a unit's events with full metadata — key, size, type,
timestamp, sensor location, setup name, per-channel peaks, peak vector sum —
then download and decode any of them, waveform or histogram.
`ref.filename` generates the name THOR would have used
(`UM12947_20260923163319.IDFW`), returning None rather than guessing when the
record type is unknown, because `read_idf_file()` dispatches on exactly that
suffix.
The load-bearing test replays THOR's captured six-event session and asserts
**every byte we emit matches its 74 frames**, decoding all six events along the
way. Read-only, like the layers under it.
- **A per-event decode self-check.** `get_event(verify=True)` recomputes the peak
vector sum from the decoded samples and compares it against the float the
*device* put in the `0x0C` record — two independent computations over the same
samples, so a disagreement means our decode is wrong. Agreement on the bench
events is **0.000%**. Worth having in a codebase whose decode failures have
historically been silent: unhandled block tags shorten a channel and nothing
raises. ⚠ It is a decode-correctness check, **not** a truncation detector — a
channel cut after its peak still yields the right PVS.
- **`SUB 0x06` content[0:4] is the event count.** Three for three across both
firmware lines (0 events→0, 6→6, 5→5), and THOR reads it *before* the chain walk
then stops without ever reading the sentinel. `list_events()` still walks to
the sentinel — correct on evidence, one round trip slower — but this lets a
caller ask "is there anything here?" in one command. `content[4:8]` reads **9**
on both units regardless of count, so it is a constant, not a count.
- **`bridges/mm_ach_server.py` — an inbound Auto Call Home receiver.** Read-only,
and deliberately more so than its Series III sibling, which has rescue actions
that stop monitoring and disable ACH. Its grace window is the experiment: it
stays **silent** after accepting, to answer the one question no packet capture
can — does the unit speak first? Captures land as `raw_bw_*`/`raw_s3_*` so
`scratch/mm_frame_parse.py` reads the pair unchanged.
⚠ Implements the **listener** path only. See *Changed* — there are two.
- **🔑 `MicromateClient.get_setup()` -- a Micromate's setup, decoded.** One `SUB
0x1A` read returns a `MicromateSetup`: record mode, sample rate, histogram
interval, pre-trigger, stop mode, record time, auto-stop, active sensors,
trigger sources, the three geophone trigger levels, mic type and (linear) mic
trigger, job number, scaled distance, and the four notes. **Measured fields
only** -- anything the reference grades inferred stays in `.raw`. A failed
checksum raises `SetupChecksumError` (a `ProtocolError`) unless `verify=False`;
a short block raises either way. The decode lives in the new pure module
`micromate/setup_block.py`.
**Verified on hardware:** against UM20147, every decoded value matched the
unit's own screen. 69 tests on 15 real reads (14 UM20147, one UM12947 cut from
Thor's 9-24 capture), with expected values taken from the operator's screen,
never from the decoder.
- **One checksum rule for three config blocks** -- `micromate.setup_block.crc_ok()`.
`content[0:2]` is a length N; a CRC-16/AUG-CCITT over `[0:N-2]` is stored at
`[N:N+2]`. Holds for `0x1A` (setup, 48 distinct states), `0x08` (preferences)
and `0x2E`; `0x2C` has none. Thor's `0x71` write omits it -- the unit computes
it -- so it is a read-side integrity check, not a write obligation.
- **`scratch/mm_config_diff.py`** -- the config diff harness (`volatile` / `snap`
/ `watch` / `diff`), read-only. An operator changes one setting on the unit's
own keypad while `watch` reports which bytes moved; this is how the map below
was built. Checks the CRC on every change to a checksummed block.
- **`bridges/mm_client_check.py` prints the decoded setup**, laid out to be
checked line by line against the unit's screen.
### Changed
- **Connecting to a unit no longer walks its event chain.** `/device/events`
reads every event header over the cellular link; on a unit with a large or
wrapped chain that takes minutes or fails outright, and it fired
automatically on every connect. Connect now uses only ~2 s probes —
`/device/info` (which already carried the compliance config the walk was
re-reading) plus `events/storage_range` — and the Device tab gains an Event
Chain card. The walk moved behind a **Load events** button in the Events
toolbar. Knowing whether a unit's ACH is on no longer requires reading every
event it has stored.
- **Recorded what THOR actually does on the wire**, measured rather than assumed.
A "status check" is **eleven commands, ~2.2 KB including TCP setup** — 18.8
MB/day per unit at a 10 s cadence, against ~0.2 MB/day for a `POLL` +
`MONITOR_STATUS` check at 60 s. The **status interval is honoured; the
connection interval is not** — it sets `(status / connection) - 1` checks per
cycle, so equal values yield *zero* cheap checks and every connection becomes
the expensive one.
- **Two THOR defects reproduced with timestamps.** After a connection drops
mid-download it retries **once**, stops polling entirely and **never resumes**,
while displaying `Connected` for as long as it is left alone — and `Idle` for a
unit that is actively recording. Separately, THOR's own log shows a
**subscription leak**: one logical event dispatched to a growing number of
handlers, **1 to 12 over ten hours** of uptime, consistent with the field
report that only a restart recovers it.
- **The Micromate's USB host supports FTDI and CDC-ACM only** — no Prolific, in
either firmware line. A PL2303 cable (Benfei) leaves a unit with no working
modem port; an FTDI cable (Sabrent) works. Both are in circulation and
indistinguishable by eye — identify by `lsusb` VID, `0403` against `067b`.
- **Six rules in the Series-4 client spec were wrong, and measuring against the
captures caught all six before any code shipped.** Each fails *silently* —
a frame the unit ignores, or a checksum that reads as bad:
requests escape **four** byte values (`0x02 0x03 0x04 0x10`), not one, so the
Series III builder reproduces only **161 of THOR's 218** read frames and misses
*every* `SUB 0x5A` download; the response checksum is **plain SUM8** of the
de-stuffed payload, not the DLE-aware variant, which disagrees with the wire on
**55 of 251** frames; `SUB 0x5A` is a **1024-byte chunk loop**, not one request
per event; `SUB 0x0A` is the **monitor-log walk** (same request repeated,
device-side cursor), not a keyed event-header read; `1E`/`1F` carry **token
`0xFE`** at `params[7]`; and `SUB 0x01` has **no THOR precedent at all**.
Recorded in `docs/micromate_protocol_reference.md` as corrections in place.
- **`SUB 0x0C`'s peak float is the per-sample peak vector sum** — resolved after
being marked *do-not-rely-on*. Exact to **0.000%** on all four bench waveforms
against a PVS recomputed from decoded samples, so its offset (`Tran` label − 12)
is established rather than inferred. The earlier "not the vector sum" reading
compared against `sqrt(Σpeak²)` from the three *reported* peaks, which is an
upper bound: the channel maxima do not occur at the same instant. **This gives
the decoder a free self-check** — the device computed that number from the same
samples, independently of our codec, so a mismatch means the decode is wrong.
Worth having in a codebase whose channel truncations have historically been
silent.
- **Cellular costs ~0.65 s per round trip, independent of payload size.**
Measured on UM12947 over an RX55: `list_setups()` on a unit with 24 setups takes
**16.0 s**, against 0.46 s over USB, for 24 commands. A 1,024-byte chunk and a
16-byte state read cost the same. **Over cellular, minimise round trips, not
bytes** — cache the setup list rather than refreshing it on a timer, and note a
13 KB event is 14 chunks ≈ 8.4 s of latency against ~0.03 s of data. The modem
also needs **fewer** reads than USB, not more: it buffers ~1 s then forwards one
large segment where CDC-ACM delivers many small ones.
- **Event keys collide across units.** UM20147's first event and UM12947's first
event are both `055d4a81` — different sizes, different contents, identical key.
The counter starts from the same value on every unit, so **a key is meaningless
without its serial**. Anything that stores, deduplicates or addresses Series IV
events must key on `(serial, event_key)`; keyed on the event key alone, one
unit's event is silently treated as a duplicate of another's and simply never
ingested. Series III has the cousin of this — its counter resets after an
erase, so keys are reused *within* a unit, which is why `ach_state.json` already
tracks `max_downloaded_key` per serial.
- **Setup file names are spelled three ways by three commands.** In one session
on one unit: `0x41` reported `test2.MMB`, `0x40` reported `test2.mmb`, and `0x0C`
reported `test2`. **Compare setup names case-insensitively and without the
extension** — an exact-string test of "is the active setup one I know about?"
answers *no*.
- **16,384 bytes per `0x5A` request, up from THOR's 1024.** Measured on UM20147
with every size checked byte-for-byte against a 1024 B control: 1 K / 2 K / 4 K
/ 8 K / 16 K all served in full, and anything larger is **silently clamped to
16,384** — correct bytes, short length, no error.
⚠ **That clamp is why the download loop now tracks its offset by bytes
received** rather than striding by chunk index. A fixed stride would either
fail on a clamp or skip the bytes it never collected; tracking what arrived
makes a clamp cost one extra request and makes the loop self-correcting against
any short response. Consequence worth stating because it reverses an earlier
decision: **a short chunk is no longer an error.** The device returns short
legitimately; the protection is the offset arithmetic plus the final
total-length check, which still raises on a genuinely truncated event.
`THOR_CHUNK_SIZE = 1024` remains available and the replay tests pin it.
Confirmed over a cellular PAD as well as USB: 14,176 B in one frame, intact.
- **⚠ Corrected: cellular cost is NOT independent of payload.** This changelog
and the protocol reference both previously said **"~0.65 s per round trip,
regardless of payload"**, and the design advice drawn from it — *minimise round
trips, not bytes* — was too strong. Every measurement behind that claim had a
payload under 1 KB (59 B status, 266 B setup records, 1024 B chunks), so the
byte term was small and similar across all of them and per-command cost looked
constant. It was a narrow-range fit extrapolated past its evidence.
Measured against a 14,176 B single response over an RX55:
**`t ≈ 0.21 s + bytes / 2,350`**, fitting within ±11% across a 14× size range.
The old figure is that model evaluated at 1 KB.
**The advice splits in two:** *status* work is round-trip bound (a 24-setup walk
really is 16 s, so cache it), while a *download* is **throughput bound** — the
16 KB chunk size saves ~30% on a large event, **not 14×**, because most of the
time is bytes on the wire and batching does not touch it. A 72,560-byte event
is ~46 s at 1024 B and ~32 s at 16,384 B.
- **⚠ Retracted: there is no `SUB 0x5A` streaming mode.** The reference
hypothesised that `offset_hi = 0x10` meant "stream until done", reconciling
THOR's chunk loop with a 2026-09-23 note about a single request returning an
entire 11 KB event. Measured directly: **`offset` is simply a byte count** and
the device returns exactly `offset + 11` bytes in one frame. `0x1000` is not a
marker, it is part of the number. The probe tried **both escapings** of
`offset_hi`, which is what makes the negative meaningful — a malformed frame
would have produced the same silence, and Series III requires that byte raw in
this very command.
- **Verified on real hardware across both firmware lines and both transports.**
Identical wire bytes over USB CDC-ACM and an RX55; every `11.0BD` inference
confirmed on UM20147 — including the four extra trailing bytes in `SUB 0x1C`
that make Series III's from-the-end offsets report **577.92 V**; a monitoring
unit answers reads with no `SESSION_RESET`; and `0x0C` content[11] gives the
record type (`0x07` waveform / `0x08` histogram) on 7 events across both lines.
⚠ **Event keys collide across units** — UM12947 and UM20147 both have an event
`055d4a81`, different sizes, different contents. Anything that stores or
deduplicates must key on `(serial, event_key)`; `MicromateEventRef.uid` is that
pair.
- **🔑 The Series-4 call-home session is captured end to end.** A MITM between a
unit's modem and THOR 1.5.0.29: **101 request frames, 101 responses, 0 bad
checksums, 34,872 B of event data in 65 s.** **Every command in a real ACH
session is one `micromate/protocol.py` already implements** — `POLL`×36,
`BULK_DOWNLOAD`×27, `STATE`×10, `EVENT_RECORD`×8, `EVENT_NEXT`×7,
`STORAGE_RANGE`×4, `MONITOR_STATUS`×3, `ARM_EVENT`×3, `SERIAL`, `EVENT_FIRST`
— bar one. **The last protocol unknown is closed.**
- **🔑 Call-home has TWO paths, and timing decides which runs.** If anything
already holds the modem's single TCP session, the unit's `RADIO RING` travels
**up that existing connection**; if nothing is connected, the modem **dials
out** to a listener. THOR's `UnitWatchDogTimer` reconnects continuously, so
THOR usually holds that slot — which is why probes and relays see "connected,
no reply". **That is contention, not a fault**, and it accounted for a full
afternoon of apparent failures.
- **⚠⚠ `SUB 0xA2` ends a call-home on Series IV — and is CONFIRM ERASE on
Series III.** Same opcode, same `0x5D` response, opposite consequence: on a
MiniMate Plus it is the final step of the erase-all sequence. `minimateplus`
and `micromate` already share a transport, so **any shared path must dispatch
on series before that byte reaches a wire.** Corroborates the firmware string
`CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING` found by static analysis.
- **⚠ "Monitor While Calling Home" silently blocks erase, and THOR reports the
session successful anyway.** Both refusals are INFO lines. Delete-after-
download is the necessary fleet setting; a unit left on monitor-while-calling
accumulates events forever while looking healthy.
**Consequence: a receiver cannot rely on erase to manage storage** — the
server-side high-water mark is load-bearing, not an optimisation. Detectable
on any call from `0x06`'s event count plus `0x1C`'s memory fields.
- **⚠ Corrected: `0x06` content[4:8] is the monitor-log count, not a constant.**
Recorded in this file as "9 on both units regardless". It reads 47 against
THOR's `Monitor Log count: 45` twelve minutes earlier on the same unit; both
units simply held 9 records.
- **⚠ Corrected: `SUB 0x49` has a third state.** `0x00` idle, `0x02` monitoring,
and **`0x03` in-call-home** — ten for ten through a session. Exactly why the
rule is *test for non-zero*: `== 0x02` calls a unit mid-call-home idle.
- **THOR rewrites a unit's stored IP from the call-home source address**, so a
relay silently poisons its record of where that unit lives.
- **`CLAUDE.md`'s "Where things stand" refreshed** — it still claimed `micromate/`
had no live client, and that the call-home was the only protocol unknown.
- **🔑 The Series-4 setup block (`0x1A`) is mapped.** Two keypad passes on
UM20147 (10-17, 10-19), every moved byte attributed to a setting the operator
named: record mode `[5]` (`01` Waveform, `02` Manual, `03` Histogram, `04`
Combo -- S3's codes), sample rate `[6:8]`, histogram interval `[8:10]`,
pre-trigger `[12:16]` (f32, **negative** seconds), stop mode `[17]`, record
time `[18:22]`, auto-stop `[23]`, active-sensor / trigger-source bitmasks
`[25]`/`[29]`, scaled distance `[30:38]`, report flags `[39]`, job number
`[40:42]`, notes from `[122]`, trigger level at channel `+30`. Full map and
grades in `docs/micromate_protocol_reference.md`.
- **⚠ The six channel blocks are three geophones, the ACTIVE mic, and two stored
mic setups.** Switching mic type copies block 5 or 6 into block 4. Reading
the mic from 5 or 6 describes a mic that is not fitted.
- **⚠ `0x1A` reads the keypad's edit buffer, live**, and a discard reverts it.
Loading a setup replaces the active config **byte-for-byte**; the setup name
is the only link to the file, and its spelling varies (`.MMB` after a keypad
save, `.mmb` after a load).
- **⚠ The unit converts units with its own constants**: distance ft ÷ 3.2808 to
metres, charge weight lb ÷ **2.21** to kg (not 2.20462). Convert back with
them or 45 lb reads 44.89. Scaled distance is computed for display, not stored.
- **`0x08` is the preferences block, not an event index.** Display units live
there (`content[31]`); switching them moves nothing in `0x1A`.
- **The geophone scale is in the unit's own config.** Channel `+24` reads
`3.1030800342559814`; ÷ 10,000 it equals `_GEO_LSB_IPS` to 1.1e-8 -- an
independent confirmation of a value previously pinned only statistically.
- **`0x1C` content[6] is a ~64 ms sub-second tick**, not a status byte -- read
once a second it aliases into a tidy-looking slow counter. A `0x1C` block is
never byte-identical to itself; compare named fields, never whole blocks.
- **⚠ Rule recorded: never write modem baud rate or modem type remotely.** The
remote link *is* the modem port; a mismatch strands the unit until a site
visit. (Baud is in none of the six blocks we read; nothing writes it.)
- **⚠ Corrected in the reference:** two 16-byte slips in the 9-24 write map --
note labels at `0x7A` (not `0x8A`), channel blocks from `0x6AC` (not `0x6BC`).
- **🔶 Series III, inferred only:** S3's 6-byte "stable anchor"
`be 80 00 00 00 00` sits exactly where Series IV keeps pre-trigger (−0.25 s)
and stop mode (Fixed). An S3 unit in **Auto** stop mode would lose it and
decode no mode / rate / interval / record time. Production is unaffected
(Blastware file ingest). Recorded in `instantel_protocol_reference.md`;
**no code changed** -- one Blastware capture in Auto mode settles it.
### Migration
**None.** No codec change, no waveform-store change, no DB or schema change,
and **no `TOOL_VERSION` bump** — so no `backfill_sidecars.py` /
`backfill_event_shape.py` run is owed. The webapp is served from the image, so
its changes appear after the next `sfm` rebuild.
The Series-4 live client adds **new** modules under `micromate/`
(`framing.py`, `protocol.py`, `client.py`) and appends three dataclasses to
`micromate/models.py`; `micromate/idf_file.py` — the codec — is untouched, and
nothing under `sfm/` or `minimateplus/` changed. The new modules are additive
and nothing imports them yet, so an existing deployment behaves identically.
⚠ The chunk-size and short-chunk changes are **internal to
`micromate/protocol.py`'s download loop**, which no shipped code path calls — the
only callers are the new client and the bench tooling. Nothing in `sfm/` or the
ingest path is affected.
⚠ Likewise `bridges/mm_ach_server.py` and the bench tooling have **no shipped
caller**, and `micromate/client.py` gained only a ring-answering branch inside
that ACH path. Nothing under `sfm/` or `minimateplus/` changed.
⚠ **The `SUB 0xA2` collision above is documentation, not a fix.** `minimateplus`
can already send `0xA2` as the last step of its erase sequence; nothing yet
prevents a future shared path from confusing the two meanings. A guard is
outstanding.
The Series-4 config work adds **one new module**, `micromate/setup_block.py`
(pure, no I/O), a `MicromateSetup` dataclass in `micromate/models.py`, and
`MicromateClient.get_setup()`. All additive; nothing under `sfm/` or
`minimateplus/` changed, and nothing shipped calls the new code. **No codec,
store or DB change, no `TOOL_VERSION` bump, no backfill.** Its 15 test fixtures
are force-added under the gitignored `tests/fixtures/micromate-setup/`.
---
## v0.31.0 — 2026-09-18
**Report parity, and a second way to rescue a runaway unit.** Two threads.
The first closes out Blastware Event/FFT-Report parity: the FFT, the USBM
RI8507 compliance chart and the sensor self-check now render on the event
report, reverse-engineered against BE12844 (MiniMate Plus) and UM (Thor)
events. The sensor check is decoded for **both** series and standardized into
the `.h5` (schema **v2**, a new `/sensor_check` group), so SFM serves it
device-agnostically rather than decoding at report time. The Inspector — an
annotated hex reader for series-3 binaries — is what made the trailing-block
structure findable, and it earned its keep by *ruling out* a stored FFT block
and proving Blastware computes it from the samples.
The second came out of a field emergency. BE12599's connector fault drove its
Tran channel to its trigger level, so the unit recorded back-to-back and dialed
the office ACH server every ~75 s, unreachable the whole time.
`bridges/ach_server.py` gained `--stop-monitoring` / `--disable-ach` /
`--rescue`, which **invert** the recovery: instead of racing a Stop into the
gaps between dial-outs, point the modem's Destination at our own ACH server and
answer the call. Proven in production the same night — the stop landed on the
first call-in and held. See `docs/runbooks/wedged_unit_recovery.md`.
⚠ **This release owes prod a backfill** — see Migration below.
### Added
- **Rescue-on-connect for `bridges/ach_server.py`** — `--stop-monitoring`
(SUB 0x97), `--disable-ach` (SUB 0x2C read → 0x7E write → 0x7F confirm) and
`--rescue` (both). They fire immediately after the startup handshake and
**before** the event walk, so a unit that is recording back-to-back on a
stuck-triggered geophone is quieted as early in the session as possible.
Each action is independently guarded — a failure does not abort the download
— and the outcome is written to `rescue.json` in the session directory.
This inverts the `docs/runbooks/wedged_unit_recovery.md` approach. That
runbook reaches the unit *inbound* and clears the modem's Destination Address
to stop it dialing. When the device is instead wedged mid-modem-init — ALEOS
logs `tcpmode trying to send to invalid socket` and re-runs `Initialize Auto
answer` every ~75 s, orphaning any held inbound session — inbound cannot win.
Pointing the modem's Destination at an `ach_server` and letting the unit call
*us* gives a device-initiated session the modem bridges properly.
⚠ Prefer `--stop-monitoring` alone on first contact. `--disable-ach` stops
the unit calling, which is the only channel to a unit in this state; stopping
the recording ends the call-home loop on its own when ACH is
"after event recorded".
- **Blastware-compatible channel FFT (`waveform_fft`).** Reproduces Blastware's
FFT Report: DC-removed, no window, zero-padded to 4096 (0.25 Hz bins at
1024 sps), single-sided `2/N` amplitude. Matches Blastware's dominant
frequency to the exact bin and the amplitude to report precision across all
28 channels of the 7-event BE12844 oracle set. `channel_spectrum()` /
`dominant_frequency()`; tests in `tests/test_waveform_fft.py`.
- **USBM RI8507 / OSMRE compliance chart on the event-report PDF
(`sfm/compliance.py`).** The velocity-vs-frequency blasting-compliance
scatter Blastware draws in the upper-right of its Event Report: each channel's
significant cycles as `(frequency, peak velocity)` points (zero-crossing
method, so each channel's cloud tops out at its PPV) plotted against the
RI8507 Drywall (0.75 in/s) and plaster (0.50 in/s) limit curves, drawn
continuous (constant-displacement bounds meeting the plateaus — no vertical
steps). Sized and positioned to match a Blastware report, measured off the
reference PDF. A technical breakdown of the curve is in
`docs/ri8507_compliance_curve.md`.
- **Sensor self-check waveforms decoded and drawn — both series.** The little
"Sensor Check" traces (geophone ring-downs — the transducer's damped impulse
response — plus a MicL pulse train, the mic's known-signal gain check) are the
unit's proof its sensors were healthy when it recorded the event.
- **Series-3** (`minimateplus.sensor_check`): four records (`0x3c`–`0x3f`) in
the binary's trailing block, same delta-block codec as the main waveform.
Verified against all 7 BE12844 reports (mic zero-crossing = 20.1 Hz exact;
geophone ring-downs ~7.5 Hz, overswing ~3.5).
- **Series-4** (`micromate.sensor_check`): the same self-test in the Thor IDFW
fixed header — four `01 0e 3c/3d/3e/3f` records (same channel ids) storing
raw int16 traces; three-channel (mic-disabled) units carry only the three
geophones. Validated by shape + cross-event consistency.
- **Standardized into the `.h5`** (`/sensor_check`, schema v2): each series'
decoder attaches the traces to the event at decode, the writer persists
them, and `gather_report_data` reads them back — so SFM renders the strip
(flush against the waveform panel) plus the **Sensor Check → Frequency /
Overswing Ratio** sub-rows without knowing the source instrument.
- Tests: `tests/test_sensor_check.py`, `tests/test_sensor_check_idf.py`,
`tests/test_event_hdf5_sensor_check.py`.
- **Inspector tab in `seismo_lab.py` — annotated hex reader for series-3
binaries (`minimateplus/binary_annotate.py`).** Tiles a raw Blastware file
into labeled spans (header / STRT / body record-chain / trailing metadata +
calibration + sensor-check records / footer) so a binary can be combed by eye.
### Fixed
- **Event-report waveform panel — stacked-lane y-tick collision.** The lanes
touch, so each lane's bottom `-1.0` overprinted the next lane's top `1.0` at
the shared boundary. Prune the extreme ticks so each lane shows clean interior
ticks only.
- **Event-report header — serial+firmware line ran off the page.** The long
`BE##### V ##.##-#.## MiniMate Plus` string overflowed the right margin;
tighter right-column indent + BW's slightly smaller header size so it fits.
---
### Migration
⚠ **The sensor-check needs a backfill.** Existing `.h5` files are schema v1
and carry no `/sensor_check` group, so their reports show no sensor-check strip
until regenerated. `TOOL_VERSION` is bumped to **0.31.0**, so the standard
backfill regenerates every event and picks up the traces with **no `--force`**:
`scripts/backfill_thor_events.py` for series-4 (it already owed a v0.30.0 Thor
backfill — this rides along) and the series-3 sidecar/shape backfill for
MiniMate events. Purely additive — no decoded value changes, and v1 `.h5`
files read fine until then (empty strip). DB backup first, as always.
⚠ Budget **~2 h on the NAS** — ~1.5 files/sec there versus ~85/sec on the dev
box (gzip-4 in `sfm/event_hdf5.py` against a Synology CPU).
Everything else in this release owes nothing: the FFT, the USBM compliance
chart and the `ach_server` rescue flags are additive and read data already on
disk — no schema change, no DB migration.
---
## v0.30.0 — 2026-09-12
**The series-4 correctness release** — the Thor / Micromate counterpart to
v0.26.0's series-3 work. The decoder is now verified per-sample against
Thor's own CSV exports: **459 waveform files, 3,807,158 / 3,807,165 samples
exact** across three independent ground-truth corpora, and production IDFW is
**575/575** with zero truncations and zero decode failures. Series-3
re-verified **unchanged at 14,338/14,338** after every shared-codec change.
⚠ **This release owes the prod store a Thor backfill.** Every stored
series-4 geophone value is **3.3% low**, and histogram peaks from monitoring
runs longer than ~4 hours can be far worse (the interval cap discarded the
tail, frequently the part holding the peak). Run
`scripts/backfill_thor_events.py` — `TOOL_VERSION` is bumped to `0.30.0`, so
regeneration is gated correctly and **no `--force` is needed**. DB backup
first. Series-3 events are untouched by this release and do not need
re-running.
⚠ **Terra-View displays these values.** Series-4 geophone readings will rise
~3.3% after the backfill, and some histogram PPVs will rise a great deal more.
That is a correction, not a regression.
### Fixed — event-report PDF used a per-trace geo Y scale
The waveform plot scaled each geo lane to its own peak, so a small channel
filled its lane and looked as large as a big one, and the `Geo: X in/s/div`
footer reflected only whichever channel was measured first — wrong for the
other two. All three geo lanes now share one symmetric scale (max |sample|
across them, padded, 0.05 in/s floor), matching the event modal and BW's
single amp/div; the footer reflects that shared scale. Mic keeps its own psi
scale. Large events are unchanged.
### Fixed — series-4 (Thor / Micromate) decoder is now per-sample exact
Verified against **Thor's own CSV exports**, which carry a per-sample
four-column block beside every binary (`CSV/<name>.IDFW.csv`) — 1,012 paired
files that had been sitting in the corpus unused. Previous notes asserted
"Thor has no ASCII ground truth", which is why the decoder stayed pinned to a
superseded walker with an unverifiable scale factor.
| metric | before | after |
|---|---|---|
| IDFW per-sample exact | 39.1% | **100.000%** (1,057,536/1,057,536) |
| IDFW files fully exact | 0/153 | **153/153** |
| IDFW PPV median error | −3.32% | **−0.002%** |
| IDFH within 2% of Thor PPV | 51.1% | **100.0%** (858/858) |
| prod IDFW PPV median error (8 units) | −3.3% | **−0.001%** |
| decode cost | — | 6 ms/file |
Four independent root causes:
- **Geo LSB was `0.0003`, should be `0.000310308`** — the old value was Thor's
4-decimal *display rounding* of the LSB mistaken for the LSB, so every
series-4 geophone sample read **3.3% low**. Pinned to ±6e-11 by
intersecting 991,415 rounding constraints; corroborated by the ±full-scale
seed (`±32226`) in unwritten IDFH slots. Applies to IDFH too, which had a
separate (also wrong) `10.0/32768`.
- **IDFH histograms were capped at 250 intervals** — the segment validator
required the interval counter's high byte to be zero, but the counter is a
uint16 cumulative index, so every segment past interval 255 was rejected.
Any run over ~4 hours lost its tail, often the part holding the peak.
540/858 corpus files affected.
- **Record mode `00 00` (raw int16, 10-byte header) was unhandled** — the
record fell through the dispatch, silently dropping each channel's first
512 samples. This produced the long-standing "loud events truncate"
symptom. `MODE_ABSOLUTE` is now also accepted as a segment-0 preamble.
- **Body-offset search matched `00 02 00` inside record headers** — picking a
candidate part-way down the chain, which decodes a rotation-shifted body
that drops each channel's segment 0. The search now anchors on record
headers and takes the chain head.
Also fixes the separately-tracked "UM-series decodes ~1000× low" bug
(`UM11402_20260406130113.IDFW` now matches its device report exactly).
Series-3 re-verified **unchanged at 14,338/14,338 exact** after the shared
`waveform_codec` change.
⚠ **This is a codec change: the Thor store owes a regeneration.** Run
`scripts/backfill_thor_events.py` (bump `TOOL_VERSION` first, or pass
`--force`), DB backup first. All stored series-4 `.h5`/sidecar peaks are
currently ~3.3% low, and histogram peaks for runs over ~4 hours may be
badly low.
⚠ **Thor's histogram PPV has a 0.0050 in/s display floor** — 41.4% of prod
IDFH sidecars report a component PPV larger than their own vector sum. On
quiet files the decoder is now *more* accurate than that reference.
New: `scratch/verify_thor_against_csv.py`, `tests/test_idf_binary_codec.py`
(10 tests, fixtures under `tests/fixtures/thor-idf/`).
### Fixed — mic-disabled (3-channel) units
Verified on a second corpus (`9-10-26-csv-req`: UM11402, UM12947, UM20147) —
**139/139 waveforms per-sample exact (1,273,380 samples), 877/877 histograms
within 2%** (was 66.9% and 56.6%).
- **Waveform body head sat below the scan floor.** A 3-channel unit's shorter
header puts the record chain head at `0x0dba`, under the old
`_BODY_SCAN_FLOOR` of `0x0E00`. The scan couldn't see it and fell through
to the Vert segment-0 record, decoding a body shifted one position around
the channel rotation — Vert came up exactly 512 samples short. Floor
lowered to `0x0C00`; body-offset scoring now accepts 3 channels as "equal"
instead of demanding 4.
- **Histogram interval record is 56 bytes, not 72.** It is
`16 × n_channels + 8`, so mic-disabled units pack 56. Assuming 72 read 7
intervals out of every 10-interval segment then walked off alignment into
garbage decoding as ~10 in/s peaks (errors up to +191,000%). The interval
count now comes from the segment's cumulative counter and the stride is
derived from it; also recovers 4 files that decoded no intervals at all.
Combined across both corpora: **292/292 waveform files, 2,330,916/2,330,916
samples exact.** Production IDFW truncations 41 → 22.
### Fixed — `40 NN` int16 blocks with NN > 8
`data_block_len()` rejected any `40 NN` block with `NN > 0x08`. The cap had
no evidence behind it: every corpus available when it was written used only
NN ∈ {1,2,3,4,8}, so it was never exercised. Loud UM12947 events use NN of
12, 16, 20 … up to 196, and because the block walker stops at the first
unrecognised tag rather than raising, rejecting them surfaced as **silently
short channels** (e.g. Tran 1812 / Vert 2132 / Long 2324 on a file whose
export has 2324 for all three). The bound is the buffer, not a constant.
Verified against Thor exports for UM12947 (2025-07-14 … 09-25, 167
waveforms): length mismatches **22 → 0**, **1,476,242/1,476,249** samples
exact. These are not truncated recordings — the exports carry full sample
counts.
`tests/test_waveform_codec.py` asserted the cap as intended behaviour; that
assertion was wrong and has been replaced with one pinning the opposite,
carrying the evidence.
### Result across all three ground-truth corpora
**459 waveform files, 3,807,158 / 3,807,165 samples exact.** Production
IDFW: **575/575**, zero truncations, zero decode failures, median PPV error
−0.0007% across 8 units. Series-3 re-verified **unchanged at 14,338/14,338**
after every shared-codec change.
The 7 residual samples each differ by one 4th-decimal tick and are **Thor's
own rounding**: intersecting the per-sample rounding constraints over that
corpus is infeasible (the binding pair contradict by 2.3e-11, 7e-5 relative),
so no single linear LSB reproduces every printed value. `_GEO_LSB_IPS` is
already pinned to ~1e-11 — do not retune it to chase these.
---
## v0.29.0 — 2026-09-04
First release to reach prod since **v0.27.0**, so it ships **both** the
+509 -32
View File
@@ -2,7 +2,7 @@
Ground-up Python replacement for **Blastware**, Instantel's Windows-only software for
managing MiniMate Plus seismographs. Connects over direct RS-232 or cellular modem
(Sierra Wireless RV50 / RV55). Current version: **v0.29.0**.
(Sierra Wireless RV50 / RV55). Current version: **v0.31.0**.
Stack-level context — which repo owns what, and how the three project versions
pair — lives in `../terra-view/docs/tmi-stack.md`, which is also loaded as
@@ -10,10 +10,240 @@ pair — lives in `../terra-view/docs/tmi-stack.md`, which is also loaded as
---
## Where things stand (updated 2026-08-28)
## Where things stand (updated 2026-10-26)
Read this first when picking the project back up.
- **The Series-4 LIVE wire protocol is reverse-engineered end to end
(2026-09-25).** `docs/micromate_protocol_reference.md` is the Series-4
Rosetta Stone, sibling to `instantel_protocol_reference.md`. **A Micromate
answers Series III command frames** — three framing differences: responses
have **no leading `DLE`** (a bare `STX`), `payload[1]` is `0xC5` (Blastware
firmware) or `0x03` (Thor firmware) rather than `0x10`, and the data length
is a **uint16 BE at `payload[8:10]`** (as a byte it under-reads `SUB 0x1A`
by 47x). Read path, event chain, setups, scheduler, monitoring control and
per-event delete are all mapped — **and as of 2026-10-14 so is the inbound
call-home session.** There are no protocol unknowns left.
~~⚠ **No command has ever been originated against a unit by this project.**
Every write was performed by THOR while we recorded. That line is worth
keeping.~~ **Retracted 2026-10-25:** the first commands this project
originated against a **Micromate** were `0x96` / `0x97` (start / stop
monitoring) to **UM20147 on 2026-10-25**, sent by SFM at the bench with
Brian's go for each send — 4 sends, each acked and read back, each audited.
(This line was always about Series 4: the `minimateplus` stack has sent
Series-III writes — start/stop, config push, erase, call-home config — since
April 2026.) Every *other* Micromate write (call-home, setup push, delete,
scheduler) is still THOR-only, never sent by us. Details:
`docs/micromate_protocol_reference.md` → *The first commands this project
originated against a Micromate*.
**Series-4 write path, phase 2 is done (2026-10-22):** the write encoder, a
send-side opcode gate and write *plans* for start/stop, call-home enable and
the setup rewrite, reproduced byte for byte against THOR's captured frames.
`bridges/mm_dry_run.py` prints a write's planned frames from a live unit's
reads (run on UM20147: sizes equal UM12947's). `MicromateProtocol._send`
refuses every write opcode except one start/stop plan at a time through
`execute()`, on a connection with a fresh Micromate reply, and refuses `0xA2`
always. The only transmit path for a write is `execute()`, reached only from
SFM's serial-named start/stop routes through `sfm/device_access` (identity,
state, audit, read-back, never retried); the Series-3 `minimateplus` stack
and raw-socket bench bridges are outside the gate. The reproduction's
breadth is one distinct input per block (the five pushes share the same name,
prefs and trigger block).
- **✅ `micromate/` HAS a live client (2026-10-02).** `framing.py`,
`protocol.py`, `client.py` + models, **119 tests**, mirroring the
`minimateplus/` stack and reusing its `transport.py` unchanged. Connect over
TCP or serial, identify a unit, read state/clock/battery/memory, list setups,
walk the event chain and download + decode events. **Read-only** — every
write remains mapped-but-unimplemented, deliberately.
Verified on hardware across **both firmware lines** (UM12947 `11.0CB`,
UM20147 `11.0BD`) and **both transports** (USB CDC-ACM and an RX55 over
cellular), byte-identical.
⚠ **The gap is config decoding**, not the protocol: `0x1A` (2,103 B) has
about a dozen fields read; `0x2C`, `0x2E`, `0x08`, `0x01` are fetched and
undecoded. Finishing it needs a bench session varying one setting at a time,
as was done for Series III — not desk work.
- **Config decoding: first keypad pass done (2026-10-17).** 47 snapshots of
UM20147 while settings were changed on its keypad; every byte that moved is
accounted for. `0x1A` content now reads: record mode `[5]` (`01` Waveform,
`02` Manual, `03` Histogram, `04` Combo), sample rate `[6:8]`, histogram
interval `[8:10]` s, pre-trigger `[12:16]` f32 **negative** s, stop mode
`[17]`, record time `[18:22]` f32, auto-stop `[23]`, active-sensor and
trigger-source bitmasks `[25]` / `[29]` (`0x07` geo, `0x08` mic), trigger
level at channel `+30` (geo in/s, mic **psi**). Full table, grades and
method in `docs/micromate_protocol_reference.md` → *The `0x1A` field map
from a keypad pass*.
🔑 **`0x1A` ends in a CRC-16/AUG-CCITT** over `content[0:2088]`, stored BE at
`[2090:2092]` — 47/47 plus a second unit. Thor's write **omits** it (the
unit computes it), so it is a read-side integrity check, not a write
obligation. ✅ Wired in: `micromate.setup_block.crc_ok()` (2026-10-19).
⚠ **The six channel blocks are 3 geophones + the active mic (block 4) + the
stored linear / sound-level mic setups (5, 6).** Read the mic from block 4
and branch on its `+4:8` code (`2` linear, `9` SLM); labels and unit strings
are re-rendered by keypad saves and are not identifiers.
⚠ **`0x1A` reads the keypad's edit buffer live** — unsaved values show while
someone is in the menu; a discard reverts them.
🔶 **Possible Series III bug, inferred only:** S3's 6-byte "stable anchor"
`be 80 00 00 00 00` sits exactly where Series IV keeps pre-trigger (−0.25 s)
+ stop mode (Fixed). An S3 unit in Auto stop mode would then lose the
anchor and decode no mode / rate / interval / record time. One BW capture
in Auto mode settles it — see the 2026-10-17 row in
`instantel_protocol_reference.md`.
Harness: `scratch/mm_config_diff.py watch` (now per-session snapshot labels
and a built-in CRC check). ⚠ `sg dialout -c "..."` is still needed to open
`/dev/ttyACM0` from shells started before the `dialout` membership.
⚠ **When diffing, get the operator's own account of what was pressed** before
labelling a run — twice on 10-17 a run was attributed to the setting that
had been *asked for*, and both were wrong.
Not yet mapped: job number, scaled distance, GPS, aux I/O, SLM options,
four unknown head runs, channel `+46:48`.
**2026-10-19 — setup loading done, plus prefs.** Loading a `.MMB` replaces
the active config **byte-for-byte** (3 loads; only differing fields move, no
load marker). Also measured: job number `[40:42]` + report flags `[39]`
(`0x02` job no., `0x08` scaled distance, `0x01` unknown); distance `[30:34]`
metres and charge weight `[34:38]` kg, **converted with the firmware's own
constants ft ÷ 3.2808 and lb ÷ 2.21** (not 2.2046 — convert back with 2.21 or
45 lb displays as 44.89); notes at `[122+64n]`/`[144+64n]` (the reference's
`0x8A` and `0x06BC` were 16-byte slips, corrected in place).
🔑 **`0x08` is the preferences block, not an event index** — display units
live there (`content[31]`), and switching them moves nothing in `0x1A`.
🔑 **One checksum rule covers `0x1A`, `0x08` and `0x2E`:** `content[0:2]` = N,
CRC-16/AUG-CCITT over `[0:N-2]`, stored at `[N:N+2]`. `0x2C` has none.
`0x2C` session timeout lives at `[118:120]` in an unknown encoding; modem
baud is in none of the six blocks.
⚠ **Never write modem baud or modem type remotely** — the remote link *is*
the modem port; a mismatch strands the unit until a site visit.
"Monitor While Calling Home" is Thor/Blastware-only, so it waits for a THOR
round. Next on config: that THOR round (a many-differences setup + the
`0x2C` fields).
✅ **`MicromateClient.get_setup()` decodes all of the above (2026-10-19)**
— `micromate/setup_block.py`, measured fields only, checksum-verified,
69 tests on 15 real fixtures (`tests/fixtures/micromate-setup/`, force-
added). `bridges/mm_client_check.py` prints it; Brian matched every line
against UM20147's screen.
✅ **SFM speaks Series 4 by serial (phase 1a, 2026-10-20):** `/device/info`,
`/device/monitor/status` and `/device/settings` take `serial` and return one
shared shape for both series through `sfm/device_access/`. Micromate lines
are held open (one call-up, keep-alive 60 s, idle hang-up 5 min, released on
RADIO RING); MiniMates still reconnect per request. Without `serial` the
legacy Series-3 path is unchanged.
✅ **Phase 1b (2026-10-21) lists and downloads events by serial for both
series** -- the MiniMate list comes from headers only (no 5A), and a download
is checked and stored in SFM's DB (`db_event_id`). Bench-checked on UM20147:
5 events, a waveform that verified, a histogram, one call-up for the whole
sequence. ~~⚠ The MiniMate header walk is **unproven on a unit; a MiniMate
bench check is owed before the branch merges.**~~ **2026-10-25, first
MiniMate bench run (BE9441, serial cable):** the header walk listed 20
events correctly, and the check found four bugs, all fixed and tested on its
logged bytes.
1. **Every non-first event SFM assembled was 2 bytes short.** The body
builder assumed the 0x1002/0x1004 metadata pages in every 5A stream; it
now reads each A5 reply's echoed address. This also affected legacy
`get_events` and `ach_server.py` files. Blastware's own files were not
affected.
2. **A reboot mid-download stored a partial event as a success.** A strict
5A stream now raises on any early end. The reboot itself was ours: the 5A
request had a bare `0x02` checksum, which the unit reads as STX. A 5A
checksum in {02, 03, 04, 10} is now DLE-escaped (re-run 2026-10-26).
3. **The unit boots when its port opens** and ignores a POLL sent before the
`Operating System` banner. Startup now waits for it.
4. **The 0x15 serial is a C string** (`"BE9441\x00?"`).
Series-3 downloads are now checked against the unit's own 0C peaks before
being stored. **Re-run 2026-10-26:** every event that does not cross a
64 KB page downloaded whole and verified (events 0, 1, 3, 4, 10). ~~The two
that cross one (events 2, 19) are refused by name.~~ **Later the same day the
page bug was fixed** (see the ✅ FIXED entry below): a fresh 8 events, 4 of them
crossing a page, all downloaded byte-identical to Blastware's own files. Stale
id gives 409, a repeat gives `already_stored`, also against Blastware's imported
copy. **Evening 2026-10-26 (measured):** a 71 KB histogram (139 requests, two
64 KB crossings) downloaded byte-identical to Blastware's, and SFM **stopped**
the unit through the new audited path (acked, read back idle). That needed
`d990466`: the 0x1C flag reads **0x0B** during a histogram run (only 0x10 had
been measured), and the status decode had to unescape before counting from the
end. **Start too (2026-10-27 00:12):** idle → monitoring, verified -- once a
start's read-back waited out the ~30 s sensor check and re-sent the wake
(`9886422`, `ca5c401`; a monitoring MiniMate answers nothing until woken, and
nothing during its sensor check). Still owed before merge: #47 from dev, and
`persist_download` aligned with dev's waveform-time restamp (spec).
- **Phase 1c: the SFM webapp by serial (2026-10-29), built; bench pass owed.**
`sfm/sfm_webapp.html` has a **Serial** field beside host/port. With one, the
Live tabs use the serial-based routes for both series: identify, status (now
with the unit's clock and event count), settings (read-only), the event list
with a Download per row (checked, stored, then opened from the store), and
audited start/stop (asks first, one send, shows the ChangeResult as it is).
Hang up appears for a Series 4. Every series-specific control follows the
unit's own `/device/info` answer, never the typed serial, and drops the
moment the serial, host or port is edited. Config and call-home **writes are
off for both series** (phases 5 and 4); Diagnostics is enabled only for a
confirmed Series 3. Without a serial every read behaves as before.
The page keeps every routing and button rule in one block of pure functions
between `/* <device-routing> */` markers, run through **Node** by
`tests/test_webapp_device_routing.py` (skipped when `node` is absent); a
static test fails if a `/device/` URL is built anywhere else.
**Server side:** the legacy Series-3 writes and erase -- `POST /device/config`
(and `/config/project`), `/events/erase`, `/rescue` (when it disables ACH or
erases), `POST /device/call_home` -- read the unit's serial (or reuse the one
`connect()` read) and refuse 409, nothing sent, unless it is Series 3 and,
when `serial=` was given, that unit. 0xA2 is CONFIRM ERASE on a MiniMate and
ends a call-home on a Micromate. The stop tools (legacy `monitor/start|stop`,
`stop_monitoring_blind`, `_slow_drip`, `_spam`) are exempt: 0x96/0x97 mean
the same on both series, and the blind tools must reach a unit too wedged to
answer.
**Bench pass done 2026-10-29** (both series, each on its own modem): 16
findings in the spec (*Left open by the 1c bench*) -- the S3 settings decode
reads escaped bytes (#1), S3 downloads skip the file reader (#8), the S3
start read-back does not reconnect after the modem drops the line (#9), an
audit `sent: null` (#15), and page polish.
**Ring path measured the same night:** with THOR's watchdog off, a call-home
reaches THOR when nobody holds the line, and **is lost when SFM holds it** --
the unit takes SFM's connection for the call, times out and does not retry.
While THOR polls a unit, SFM gets no reply and does not disturb THOR.
✅ **Line hold decided (Brian, 2026-10-29): keep it as is for now; the
long-term fix is SFM handling auto call-ins itself.** The ring-path merge gate
is settled. THOR's log: `C:\THORDATA\Logs\`.
Next: a short fix plan for the findings, then phases 4 and 5.
- **✅ Phase 3: start / stop monitoring by serial (2026-10-23) — built,
reviewed, and bench-verified on UM20147 (2026-10-25).** Start acked in
0.46 s and read back as monitoring at the first 2 s poll (during the sensor
check); stop acked in 0.12 s, then `0x49` read a new value **`0x01` for ~18 s**
(inferred: the unit's call-home attempts after a stop — refused as unmeasured
until settled) before idle; a stop while idle is a harmless 10 ms no-op. The
Series-3 path is unproven on a unit (MiniMate bench check owed). Both
series go through one safety core, `sfm/device_access/change.py`: a fresh
identity read, the run state (calling home or never measured is refused),
`dry_run` (the exact frames, nothing sent), a row in the new
`device_commands` audit table (`GET /db/device_commands`; `sent` says whether
a frame went out, `states` keeps every read), one send never retried, then a
read-back. The HTTP status is an allow-list -- only a dry run, a skip or a
send read back as made is a 200 -- and a failure after the send says so and
names its audit record.
- **🔑 ACH / call-home, captured end to end (2026-10-14).** A Micromate signals
`RADIO RING`; **two paths exist and timing decides which**: if anything
already holds the modem's single TCP session the ring rides that connection,
otherwise the modem dials out to a listener. THOR's `UnitWatchDogTimer`
reconnects continuously, so THOR usually holds that slot — which is why
probes and relays see silence. That is contention, not a fault.
⚠⚠ **`SUB 0xA2` ends a call-home on Series IV and is CONFIRM ERASE on
Series III** — same opcode, same `0x5D` response, opposite consequence.
`minimateplus` and `micromate` share a transport; dispatch on series before
that byte reaches a wire.
⚠ **"Monitor While Calling Home" silently blocks erase**, and THOR reports
the session successful anyway. A receiver therefore **cannot rely on erase to
manage storage** — the server-side high-water mark is load-bearing.
⚠ `bridges/mm_ach_server.py` implements the listener path only; it needs to
also hold outbound connections and watch for the ring.
- **Bench tooling for device diagnosis (2026-09-25).** `bridges/mm_probe.py`
distinguishes the four faults THOR reports identically as "disconnected"
(refused / connect timeout / **connected but no reply** / replied) and names
what to try next. `bridges/mm_link.py` is a stand-in for a cellular modem
with a decoded log and fault injection. `scratch/mm_frame_parse.py` exists
because **`S3FrameParser` cannot see Micromate responses at all** — it scans
for `DLE+STX`, which never appears in Series-4 traffic.
- **A Micromate's USB-A host port drives FTDI and CDC-ACM only** — no Prolific,
in either firmware line. TMI buys both Sabrent (FTDI) and Benfei (PL2303)
cables and they are indistinguishable by eye. A PL2303 cable leaves a unit
with **no working modem port at all**; identify by `lsusb` VID, `0403` vs
`067b`. This accounted for a unit that could not be deployed.
- **Series-3 decode is verified per-sample at scale (v0.27.0).** The full DL2
archive decodes **14,338 / 14,338** paired files exactly against their
preserved Blastware ASCII exports — 1,249 waveform + 13,089 histogram, 45
@@ -24,9 +254,104 @@ Read this first when picking the project back up.
Independent corroboration of the 32000-count scale: 19,244 healthy
channel-events sit at a pre-trigger floor of exactly 0.000 (62.7%), 94.5%
within ±1 quantisation unit, median +0.0000 — no zero-point bias.
- **Series-4 (Thor / Micromate) is NOT verified.** UM-series sits at ~48%
against device peaks with a ~1.7% systematic bias and a near-zero tail.
Thor IDFW is pinned to `decode_waveform_legacy` deliberately.
- **Series-4 (Thor / Micromate) is now verified per-sample (2026-09-10).**
**1,057,536 / 1,057,536** geo samples across all 153 genuine Thor waveform
files reproduce Thor's own CSV export exactly; IDFH peaks are within 2% on
858/858 (median -0.004%). The ground truth was in the corpus all along —
Thor writes `CSV/<name>.IDFW.csv` beside each binary with a **per-sample**
four-column block. Harness: `scratch/verify_thor_against_csv.py`.
Four bugs, all fixed: geo LSB was `0.0003` (display rounding of the real
`0.000310308`, so every sample read **3.3% low**); the IDFH segment
validator required a zero counter high byte, **capping every histogram at
250 intervals**; record mode `00 00` (raw int16) was unhandled, silently
dropping each channel's first 512 samples; and the body-offset search
matched `00 02 00` *inside* record headers, decoding a rotation-shifted
body. IDFW is no longer pinned to `decode_waveform_legacy`.
Series-3 re-verified unchanged at 14,338/14,338 after the shared-codec
change.
- **Mic-disabled (3-channel) units are a distinct shape (2026-09-10).**
Verified on a second corpus (`~/thor-csv-req`, UM11402/UM12947/UM20147):
**139/139** waveforms per-sample exact, **877/877** histograms within 2%.
Two structural differences: the shorter header puts the waveform record
chain head at `0x0dba` (below the old `_BODY_SCAN_FLOOR` of `0x0E00`, so it
was invisible and Vert came up exactly 512 short), and the histogram
interval record is **56 bytes, not 72** — `16 × n_channels + 8`, derived per
segment from the cumulative interval counter, never assumed.
- **`40 NN` blocks are not capped at NN=8 (2026-09-11).** `data_block_len()`
rejected `NN > 0x08`, a guard with no evidence behind it — the corpora
available when it was written only used NN ∈ {1,2,3,4,8}. Loud UM12947
events use NN up to 196, and since the walker stops at the first
unrecognised tag rather than raising, this surfaced as silently short
channels. Verified on 167 UM12947 waveforms: length mismatches 22 → 0,
1,476,242/1,476,249 samples exact.
- **Production IDFW is now 575/575** — zero truncations, zero decode
failures, median PPV error −0.0007% across 8 units (was 41 truncated + 1
failing, −3.3%). Across all three ground-truth corpora: **459 files,
3,807,158/3,807,165 samples exact**; the 7 stragglers differ by one
4th-decimal tick and are Thor's own rounding — no single linear LSB can
reproduce every printed value (the constraints are infeasible by 7e-5
relative), so do NOT retune `_GEO_LSB_IPS`.
- **✅ FIXED 2026-10-26 (`887e75d`) — was: "KNOWN BUG — the 5A walk breaks once a unit's buffer crosses 64 KB."**
Kept below as history. The fix came from a recording of Blastware downloading all 8 of
BE9441's events, 4 crossing a page (`tests/fixtures/minimate-bench-10-26-26-blastware/`):
- **Every MiniMate request DLE-escapes 02, 03, 04 and 10**, payload and checksum alike
(748/748 re-encode). `build_bw_frame` had escaped only 0x10.
- **A 5A request is an ordinary request carrying a LENGTH and a 4-byte linear ADDRESS.**
The walk: the event's start, +0x200 carrying into the page byte, then TERM at the
next boundary for the remainder.
- **The old model misread the same bytes.** The "offset 0x1002" is length 0x0200
escaped; the "metadata pages at 0x1002/0x1004" are event 0's chunks at 0x0200 and
0x0400; the 16-bit counter could not leave its page.
- **Verified on BE9441**, live: all 8 events, including 4 page crossings, downloaded
whole and matched the unit's own peaks.
⚠ Sections below that describe "partial DLE stuffing", "11-byte params", "offset_hi
0x10 raw" and "metadata pages 0x1002/0x1004" are that misreading. They are retracted
here, not deleted.
**Review follow-ups (2026-10-26):** the walk's chunk cap is now sized from STRT (a
caller's 128 cut every event past ~66 KB; 2,545 of 63,500 archived histograms are
bigger); a STRT claiming less than one chunk or more than 4 MiB is refused as a
misread; a TERM is sent only for a true tail. Still open, none measured: an event
ending exactly on a chunk step sends a zero-length TERM (as the old code did; 1 in
512, never seen); with no STRT the legacy walk still reads `max_chunks` blind.
🔶 **Inferred only, do not act on it without a capture:** `build_bw_write_frame`
("raw except BW_CMD", "DLE-aware checksum") carries the same fingerprints as the
retracted 5A model: SUB 71's "offset 0x1004" reads as length 0x0400 escaped, and
Blastware escapes `03` in write data. A write whose payload holds a bare
02/03/04/10 may be malformed. One Blastware config-write capture settles it.
🔑 **Replies follow the same rule (measured, 748/748):** every 02/03/04/10 escaped,
checksum = SUM8 of the unescaped payload. The "S3 checksums frequently fail" belief
is `S3FrameParser` summing its output with the `10` of `10 02/03/04` still in it.
~~**⚠ KNOWN BUG — the 5A walk breaks once a unit's buffer crosses 64 KB.**~~
`parse_strt_end_offset()` returns only `(end_key[2] << 8) | end_key[3]`,
discarding the key's page byte. An event starting at `0x0111F2A2` and ending
at `0x0112_1010` therefore reads `end_offset = 0x1010` — *behind* its own
start. The chunk loop then exits before fetching anything and TERM computes
a negative `offset_word`, which `struct.pack(">H", ...)` rejects: the
`/device/events` walk 500s. Reproduced on BE12599 (2026-09-19), which had
78 KB stored and had rolled into page `0x12`.
**Why it hid so long:** every 5A capture the walk was verified against came
from a freshly-erased BE11529 — all three confirmed TERM examples in
`framing.py` (`0x1ABE`, `0x21F2`, `0x417E`) sit inside page `0x11`. Prod is
unaffected: it ingests complete files via BW ACH, never this walk.
**Fixing it has two layers** — the arithmetic (`if end < start: end +=
0x10000`) stops the crash and bounds the loop correctly; carrying the page
byte through the chunk requests (`params[1]` 0x11 -> 0x12, counter rolling
over) needs a BW capture of a spanning event first. Do not ship layer one
alone without a loud truncation warning — a silently short event is the
failure mode this codec has been bitten by repeatedly.
**Narrowed 2026-10-26 (BE9441, measured):**
- The one-event download now refuses a spanning event by name (502), before
any chunk.
- STRT carries the full 32-bit end key, so the page is there to use.
- A read-only test walk carrying the page byte got a proper reply for the
first chunk in the next page (`01 12 01 2c`). The second chunk, params
`… 01 12 03 2c`, got none: a raw `0x03` inside the params.
- Pages after `0x11` have counters with `02`/`03`/`04` bytes. Page `0x11`
has none, because event 1 skips `0x0000`–`0x05FF`.
- How Blastware encodes those bytes is the one unknown left. The capture to
take: Blastware downloading BE9441 event 2 (`0111c92c`) or 19 (`0118a4ca`)
through the recording bridge. Blastware's own files for both are fixtures
(`tests/fixtures/minimate-bench-10-25-26/blastware/`), as byte-exact targets.
- **Open, not blocking:** 14 sensitive-range files show an exact 8x
(= 10.0/1.25) units discrepancy; `scripts/backfill_sidecars.py --force` also
inserts DB rows for store files that have none (one-time per store) and the
@@ -40,6 +365,9 @@ Read this first when picking the project back up.
**v0.27.0 does NOT owe prod a backfill** — verified: the partial-final-block
fix changes 0 of the 10,215 histograms in the prod store (the 4 recovered
files are archive-only and were never ingested).
✅ **The v0.30.0 Series-4 backfill HAS been run on prod (2026-09-25).** Every
stored Series-4 geophone value was ~3.3% low until then; that is corrected and
the job does not need repeating.
- **The "offset" hardware fault has its own journal** --
`docs/offset_investigation.md`. **5 of 45 units (11%)**, and the fault is
**persistent** — it stays until the geophone is serviced. Detect it with
@@ -51,7 +379,59 @@ Read this first when picking the project back up.
`SUB 0x0E` (unimplemented), which may carry those very numbers.
When new information about the protocol is discovered, please update the instantel_protocol_reference.md with the findings in addition to this document
When new information about a protocol is discovered, record it in the matching
reference **in addition to** this document:
| series | document |
|---|---|
| Series III (MiniMate Plus / BlastMate) | `docs/instantel_protocol_reference.md` |
| **Series IV (Micromate / THOR)** | **`docs/micromate_protocol_reference.md`** |
| Thor IDF file format | `docs/idf_protocol_reference.md` |
Both protocol references carry retractions in place rather than deleting what
turned out to be wrong — that convention has already saved re-deriving the same
mistakes twice, so keep it.
---
## Changelog & release convention
**Feature branches do NOT touch `CHANGELOG.md`. Write the entry on `dev`, as
part of finishing the merge, under `## Unreleased`. Cut the version on `dev` in a
dedicated release commit when you are ready to ship to `main`.**
- **The changelog is written on `dev`, never on a feature branch.** With
several branches in flight they all edit the same few lines at the top of
the file and conflict every time. Writing it once, after the merge, also
lets it describe what actually *landed* — including anything that changed
during conflict resolution.
- ⚠ **The merge is not finished until `## Unreleased` is updated.** Same sitting,
not "later" — that is the one failure mode of writing it after the fact.
Reconstruct from the branch's own commit messages:
`git log --oneline dev..<branch>` before you merge, or
`git log --oneline <merge-base>..<branch>` after.
- **No preamble under `## Unreleased`** — just the `### Added` / `### Changed` /
`### Fixed` lists. The themed opening paragraph gets written at release
time, when the whole release is visible and can be named honestly. A theme
written when the first item landed is stale by the third.
- ⚠ **State the operational consequence** on any entry touching the codec, the
waveform store, or the DB — **including when it is "none."** "requires
`backfill_sidecars.py` + `backfill_event_shape.py`, ~2 h on the NAS",
"`TOOL_VERSION` bumped", "no schema change, no migration". Silence is
ambiguous; "none" is information. This repo's changelog is how future-you
learns whether a deploy costs two hours.
- **Releases are cut on judgement, not on a schedule or a merge.** `Unreleased`
is the staging area for whatever is going into the next release; when enough
has accumulated to be worth shipping, it gets a number and a date. Nothing
about a merge to `dev` triggers a release.
- **Cutting a release** is its own `chore(release): vX.Y.Z — <theme>` commit on
`dev`, renaming `## Unreleased` → `## vX.Y.Z — YYYY-MM-DD` and touching:
`CHANGELOG.md`, `pyproject.toml`, the version line in `CLAUDE.md` and
`README.md`, and `minimateplus/event_file_io.py` (`TOOL_VERSION`) **when the
codec changed** — that constant gates `.h5` regeneration.
- **`main` carries only released versions.** No `## Unreleased` section there;
it lands via the `dev` → `main` PR. `main` lagging `dev` by a version is
normal.
---
@@ -120,20 +500,34 @@ should not import from `sfm/`, must not touch a DB, and have no I/O
beyond reading files passed as arguments. Keep them pure — both
tiers can then depend on them without circularity.
#### Thor IDF binary codec (2026-05-28)
#### Thor IDF binary codec (updated 2026-09-10)
`micromate/idf_file.read_idf_file()` decodes both Thor IDFW
(waveform) and IDFH (histogram) binaries.
(waveform) and IDFH (histogram) binaries. **Verified per-sample
against Thor's own CSV exports** — see
`scratch/verify_thor_against_csv.py`.
- **IDFW** reuses `decode_waveform_v2()` on the body at fixed file
offset `0x0f1f`. Sample fidelity is 87–99% byte-exact on quiet
events; loud events hit the BW codec's known walker-stops-early
limitation.
- **IDFH** has its own segment-based decoder: `[len_be][0a 00 00 00]
[00 NN][05 3f]` + N × 72-byte interval records (4 × 16-byte
per-channel min/max/halfp). All 859 Thor IDFH corpus files
decode (181,071 intervals); peak matches sidecar within ~1.8%
(ADC quantization).
- **IDFW** uses the series-3 record-chain `decode_waveform_v2()`. The
body offset is **not** fixed: it is `<chain-head record> + 7`, found
by `_find_waveform_body_offset()` anchoring on record headers. All
**153/153** genuine Thor waveform files decode per-sample exact
(1,057,536/1,057,536 samples).
- **IDFH** segment header is `[len_be][0a 00 00 00][counter_be][05 3f]`,
where `counter` is a **uint16 cumulative interval index** — it must
not be constrained to a zero high byte (that capped histograms at 250
intervals). Intervals whose `min > max` on all channels are unwritten
slots carrying a ±full-scale seed and are skipped. 858/858 files land
within 2% of Thor's PPV (median -0.004%).
- **Geo LSB is `0.000310308` in/s per count** (full scale 10.0 in/s =
32226.05 counts). Series-3's 32000-count scale does NOT apply.
- **Record modes** are `02 00` deltas (14 B header), `01 00` absolute,
`00 03` raw 12-bit, and `00 00` **raw int16** (all 10 B headers).
`01 00` and `00 00` are also valid as the implicit segment-0 preamble.
⚠ **Thor's histogram PPV has a 0.0050 in/s display floor.** 41.4% of
prod IDFH sidecars report a component PPV exceeding their own vector
sum — impossible. On quiet files our decode is *more* accurate than
the reference; do not "fix" the decoder to match it.
The two outlier `BE9439_*` files in the Thor example corpus are
actually Series III Blastware binaries that share the `.IDFW`/`.IDFH`
@@ -169,8 +563,15 @@ minimateplus/ ← Python client library (primary focus)
sfm/server.py ← FastAPI REST server exposing device data over HTTP
seismo_lab.py ← Tkinter GUI (Bridge + Analyzer + Console tabs)
bridges/
mm_probe.py ← name the fault behind a dead unit (4 verdicts, read-only)
mm_link.py ← bench stand-in for a cellular modem, with fault injection
ach_mitm.py ← TCP relay for recording a Series-3 ACH session
docs/
instantel_protocol_reference.md ← reverse-engineered protocol spec ("the Rosetta Stone")
instantel_protocol_reference.md ← Series III protocol spec ("the Rosetta Stone")
micromate_protocol_reference.md ← Series IV protocol spec + THOR's measured behaviour
idf_protocol_reference.md ← Thor IDF file format
CHANGELOG.md ← version history
```
@@ -190,7 +591,7 @@ Full read pipeline + write pipeline + erase pipeline + monitor log + call home c
| Event header / first key | 1E | ✅ |
| Waveform header | 0A | ✅ |
| Waveform record (peaks, timestamp, project) | 0C | ✅ |
| **Bulk waveform stream (event-time metadata + full waveform)** | **5A** | ✅ **byte-perfect against BW captures (v0.14.3, 2026-05-05)** — STRT-bounded chunk walk + correct event-N probe counter + DLE-stuffed `0x10` bytes in params + concatenate-only file body assembly. All 17 5A request frames in the 5-1-26 3-sec capture reproduce byte-for-byte. |
| **Bulk waveform stream (event-time metadata + full waveform)** | **5A** | ✅ **(2026-10-26: a LENGTH read at a 32-bit ADDRESS, every 02/03/04/10 escaped — the model in the rest of this cell is retracted, see "✅ FIXED 2026-10-26")** byte-perfect against BW captures (v0.14.3, 2026-05-05) — STRT-bounded chunk walk + correct event-N probe counter + DLE-stuffed `0x10` bytes in params + concatenate-only file body assembly. All 17 5A request frames in the 5-1-26 3-sec capture reproduce byte-for-byte. |
| Event advance / next key | 1F | ✅ |
| **Write commands (push config to device)** | **68–83** | ✅ new v0.8.0 |
| **Erase all events** | **0xA3 → 0x1C → 0x06 → 0xA2** | ✅ new v0.9.0 |
@@ -399,15 +800,19 @@ with zero mismatches. Before: 1 of 1196.
`BE12599/N599LPWJ.980W` @849, `BE9558/K558LOF2.820W` @1485.
(The series-3 histogram codec was fixed 2026-08-25 — see below.)
- **Micromate (UM-series) IDF decode is ~1000× low** — e.g.
`UM11402_20260406130113.IDFW` gives a Tran peak of 0.0009 in/s against
a device-reported 1.1168. The Thor IDF path decodes sanely, so this
is UM-specific.
- **Thor IDF per-count LSB** — after the 32000 geo full-scale
correction, series-4 Thor peaks sit at a median 0.983 of the
device-reported peak (was 0.960 under 32768). Closer but not exact;
Thor likely uses its own per-count LSB rather than the BW
16-count/0.005 in/s convention.
- ~~**Micromate (UM-series) IDF decode is ~1000× low**~~ — FIXED 2026-09-10.
`UM11402_20260406130113.IDFW` now decodes Tran 1.1168 / Vert 4.3220 /
Long 0.9135, matching the device report exactly. Root cause was the
body-offset search landing inside a record header plus the unhandled
`00 00` record mode, not anything UM-specific.
- ~~**Thor IDF per-count LSB**~~ — RESOLVED 2026-09-10. The 0.983 ratio was
exactly `0.0003 / 0.000310308`. Thor's geo LSB is **0.000310308 in/s per
count** (full scale 10.0 in/s = 32226.05 counts), pinned to ±6e-11 by
intersecting 991,415 rounding constraints from Thor's own exports and
corroborated by the ±full-scale seed (`±32226`) left in unwritten IDFH
interval slots. Series-3's 32000-count scale does **not** carry over.
Note `10.0/32226` is very slightly wrong — see
`docs/idf_protocol_reference.md`.
### Decoded sample counts (across the fixture bundle)
@@ -515,6 +920,14 @@ S3→BW (response):
## Critical protocol gotchas (hard-won — do not re-derive)
### SUB 5A — bulk waveform stream — NON-STANDARD frame format
> ⚠ **RETRACTED 2026-10-26 (measured): it is a standard frame.** The payload is
> `[10 00 5A 00][length BE][address BE 4][zeros 6]` with a SUM8 checksum, and every
> 02/03/04/10 is DLE-escaped (`s3_stuff`, `build_5a_request`). "offset_hi 0x10 raw" was
> the length 0x0200 escaped (`10 02 00`). The "DLE-aware checksum" is SUM8 of the
> unescaped payload. The "partial stuffing" carve-outs were the escape rule seen half.
> All 540 of Blastware's 5A requests rebuild byte for byte
> (`tests/test_5a_blastware_walk.py`). The text below is history.
**Always use `build_5a_frame()` for SUB 5A. Never use `build_bw_frame()` for SUB 5A.**
@@ -555,6 +968,9 @@ the 1-2-26 BW TX capture (10 frames). Difference (3) confirmed against the 5-1-
"bwcap3sec" capture (17 frames, all match byte-for-byte after fix).
### SUB 5A — chunk counter formula (REWRITTEN 2026-05-01 — see 5-1-26 captures)
> ⚠ **SUPERSEDED 2026-10-26:** a chunk is addressed by a full 32-bit address, stepping
> +0x200 across page boundaries; no event-1 special case (see `read_bulk_waveform_stream`).
> ⚠️ **Everything that came before this rewrite was WRONG in important ways.** The previous
> formula `max(key4[2:4], 0x0400) + (chunk_num - 1) * 0x0400` happened to *work* for events
@@ -639,6 +1055,11 @@ several events should read 0x1002/0x1004 only once at the start.
`read_bulk_waveform_stream`.
### SUB 5A — STRT record encodes end_offset (NEW 2026-05-01)
> ⚠ **SUPERSEDED 2026-10-26:** the end is the FULL 32-bit `end_key`
> (`parse_strt_end_key`), read after removing the reply's escape bytes. The 16-bit
> `end_offset` below was the 64 KB page bug, and misread any end whose low bytes held
> an escaped 02/03/04.
The first A5 response (probe response, or the first chunk for event 2+) contains a STRT
record at byte offset 17 of the `data` field. Layout:
@@ -668,6 +1089,11 @@ Verified across 3 events:
| 5-1-26 "copy 2nd address" / DA event 2 | `011121F2` | `0111417E` | `0x417E` (event 2 span 0x1F8C = 8,076 B) |
### SUB 5A — TERM frame formula (FINALIZED 2026-05-01)
> ⚠ **SUPERSEDED 2026-10-26:** TERM is `build_5a_request(next_boundary, end -
> next_boundary)`: a read of the remainder at the next 32-bit boundary. "offset_word"
> is that length; "params[2:4]" are the address's low bytes. The tables below still
> hold as numbers.
The TERM frame fetches the partial last chunk *and* the file footer. It is **not** a simple
"goodbye" frame — its response payload contains the bytes between the last full 0x0200-aligned
@@ -703,6 +1129,11 @@ are wrong; the device's response under that path is a tiny 101-byte device-side
(arrived only after we walked the entire post-event buffer), not the proper file footer.
### SUB 5A — fixed metadata pages 0x1002 and 0x1004 (NEW 2026-05-01)
> ⚠ **RETRACTED 2026-10-26 (measured):** these are not fixed global pages. They are the
> first event's own chunks at addresses 0x0200 and 0x0400, which escape to `10 02 00` and
> `10 04 00` on the wire. A non-first event has no such reads because it does not start at
> 0x0000. Their strings are still read as described below.
Two chunk addresses are GLOBAL device/session metadata, not event-specific:
@@ -727,12 +1158,18 @@ locates the ASCII strings via label scans (`Project:`, `Client:`, `User Name:`,
dump the structural layout if more session-global fields need to be extracted.
### SUB 5A — params are 11 bytes for chunk frames, 10 for termination
> ⚠ **RETRACTED 2026-10-26:** every 5A request has the standard 10 params bytes (address +
> 6 zeros). The "11th byte" was the length's low byte, read as params.
`bulk_waveform_params()` returns 11 bytes (extra trailing `0x00`). The 11th byte was
confirmed from the BW wire capture. `bulk_waveform_term_params()` returns 10 bytes.
Do not swap them.
### SUB 5A — event-time metadata source (FINALIZED 2026-05-05)
> ⚠ **AMENDED 2026-10-26:** the strings come from the first event's chunks at 0x0200 and
> 0x0400, not from "global pages read once per session" (see the retraction above).
The metadata strings come from the two fixed metadata pages at counter `0x1002` and
`0x1004` (see "SUB 5A — fixed metadata pages 0x1002 and 0x1004" above). These pages
@@ -774,6 +1211,11 @@ that's an old-walk artifact (the broken `0x0400`-step formula occasionally caugh
pages instead.
### SUB 5A — end-of-stream (FINALIZED 2026-05-01)
> ⚠ **AMENDED 2026-10-26:** a reply's `page_key` is not a page. It is the echoed
> length plus an escape byte the parser keeps: all 532 chunk replies read `0x0010` and
> the 8 TERMs `0x0000`/`0x0001`. The walk relies on it only for the mid-stream
> terminator check, and now sends TERM only for a tail (< 0x200).
Under the v0.14.0+ STRT-bounded walk the stream ends cleanly:
@@ -939,6 +1381,7 @@ Confirmed from the 5-1-26 "Download All" capture:
1F → null sentinel
```
(⚠ 2026-10-26: the walk starts at the 0x46 key itself, as a plain 32-bit address.)
This is why event 2's first 5A chunk is at `start_key + 0x46` — that's the address of the
"real start" 0x46-record, distinct from the `0x2C`-record at the raw boundary. Use the
`0x46` keys as the input to `read_bulk_waveform_stream`, not the `0x2C` keys.
@@ -1157,12 +1600,32 @@ for 0x10 records).
GET /device/info?port=COM5 ← serial
GET /device/info?host=1.2.3.4&tcp_port=9034 ← cellular
GET /device/events?host=1.2.3.4&tcp_port=9034&baud=38400
GET /device/events?serial=UM20147&host=...&tcp_port=... ← list with event_id, either series (no 5A on a MiniMate)
POST /device/events/download?serial=UM20147&event_id=...&host=... ← download, check, store; returns db_event_id
GET /device/event?host=1.2.3.4&tcp_port=9034&index=0
GET /device/monitor/status?host=1.2.3.4&tcp_port=9034 ← battery, memory, mode
POST /device/monitor/start?host=1.2.3.4&tcp_port=9034 ← start recording
POST /device/monitor/stop?host=1.2.3.4&tcp_port=9034 ← stop recording
POST /device/monitor/start?serial=UM20147&host=...&tcp_port=...&dry_run=&even_if_already= ← audited start, either series
POST /device/monitor/stop?serial=UM20147&host=...&tcp_port=...&dry_run=&even_if_already= ← audited stop, either series
GET /device/settings?serial=UM20147&host=1.2.3.4&tcp_port=9034 ← shared-model settings, either series
POST /device/hangup?host=1.2.3.4&tcp_port=9034 ← release a held Series-4 line
```
`serial=` (UM = Series 4, BE/BA = Series 3) on `/device/info`, `/connect`,
`/monitor/status`, `/settings` returns the shared model, uncached; on `/events` and
`/events/download` it lists and downloads by `event_id`; on `/monitor/start` and
`/monitor/stop` it runs the audited change (`dry_run=true` returns the frames and sends
nothing; `even_if_already=true` sends even when the unit is already in that state). A
`UM` serial on any other `/device/*` route is 501; any request taking the legacy
Series-3 path at a held Series-4 address is 409.
The legacy Series-3 writes and erase (`POST /device/config`, `/config/project`,
`/events/erase`, `/rescue`, `POST /device/call_home`) take an optional `serial=` and
refuse 409, nothing sent, when the unit at the address does not answer as Series 3
or is not the named unit. The stop tools (`monitor/start|stop` without a serial,
`stop_monitoring_blind`, `_slow_drip`, `_spam`) are exempt by design.
SFM must run a single uvicorn worker (locks and held lines are per process).
Server retries once on `ProtocolError` for TCP connections (handles cold-boot timing).
### DB read endpoints (query seismo_relay.db written by ach_server.py)
@@ -1173,6 +1636,7 @@ GET /db/events?serial=BE11529&from_dt=&to_dt=&limit= ← triggered events, ne
GET /db/monitor_log?serial=BE11529&from_dt=&to_dt= ← monitoring intervals, newest first
GET /db/sessions?serial=BE11529&limit=50 ← ACH call-home sessions, newest first
PATCH /db/events/{id}/false_trigger?value=true ← flag/unflag false triggers
GET /db/device_commands?serial=UM20147&limit=100 ← start/stop audit trail (sent, states), newest first
```
DB file: `bridges/captures/seismo_relay.db` (default; override with `--db-path` at startup).
@@ -1184,17 +1648,30 @@ All DB endpoints are read-only except `PATCH /db/events/{id}/false_trigger`.
| Capture | Location | Contents |
|---|---|---|
| 1-2-26 | `bridges/captures/1-2-26/` | SUB 5A BW TX frames — confirmed 5A frame format, 11-byte params, DLE-aware checksum |
| 1-2-26 | `bridges/captures/1-2-26/` | SUB 5A BW TX frames — confirmed 5A frame format, 11-byte params, DLE-aware checksum (⚠ that model retracted 2026-10-26: a standard frame, length + 32-bit address) |
| 3-11-26 | `bridges/captures/3-11-26/` | Full compliance setup write, Aux Trigger capture |
| 3-31-26 | `bridges/captures/3-31-26/` | Complete event download cycle (148 BW / 147 S3 frames) — confirmed 1E/0A/0C/1F sequence; only 1 event stored so token=0xFE appeared to work |
| 4-3-26 | `bridges/captures/4-3-26/` | Browse-mode S3 capture with 2+ events — confirmed all-zero params for 1F, 1F response layout, null sentinel, 0A context requirement |
| 4-27-26 | `bridges/captures/4-27-26/` | BW "open 2sec waveform" + "copy event to disk" + paired SFM "seismo_dl" — first proof that SFM was over-reading 5× past event end. BW reads 14 chunks at 0x0200 increments + TERM at end_offset; SFM was reading 37 chunks at 0x0400 increments. STRT end_key field located. |
| 5-1-26 | `bridges/captures/5-1-26/comcheck/` | Three sub-captures: SFM 3-sec download (`seismo_dl_…`), BW comms-check + 3-sec download (`bwcap3sec/`), BW second-event download + "Download All" (`raw_*_170945`/`_171216`). Confirmed: TERM frame formula across 3 events; metadata pages 0x1002/0x1004 are global (read once per session); event-1 vs event-N chunk-pattern split; WAVEHDR length 0x46 vs 0x2C disambiguates real events from boundaries. |
| 5-1-26 | `bridges/captures/5-1-26/comcheck/` | Three sub-captures: SFM 3-sec download (`seismo_dl_…`), BW comms-check + 3-sec download (`bwcap3sec/`), BW second-event download + "Download All" (`raw_*_170945`/`_171216`). Confirmed: TERM frame formula across 3 events; metadata pages 0x1002/0x1004 are global (read once per session) (⚠ retracted 2026-10-26: event 1's chunks at 0x0200/0x0400); event-1 vs event-N chunk-pattern split; WAVEHDR length 0x46 vs 0x2C disambiguates real events from boundaries. |
---
## Write commands (SUBs 68–83) — confirmed 2026-04-07
> ⚠ **RETRACTED 2026-10-27 (#46, measured): write frames are ordinary requests.**
> Every 02/03/04/10 is escaped and the checksum is SUM8 of the payload, as in every
> request. The length field [4:6] is the data's length. A config block is its own
> length N + 2 bytes; the compliance image (2,092) goes in addressed chunks
> (params[2:4]; 512 B now, 1,024 B in March). This re-encodes all 3,869 Blastware
> requests from February to April, plus 26 write frames from 2026-10-26. The
> "raw except BW_CMD", "DLE-aware checksum", "offset = data[1] + 2" and "71×3 at
> 0x1004" below were the same frames read with their escape bytes in. The trigger
> block is READ (SUB 0x2E) -- its byte 5 differs by unit -- not a fixed blob.
> Code: `build_bw_write_frame`, `protocol.write_image`, `b5037b0`. The text below
> is history.
All confirmed from 3-11-26 BW TX capture (`raw_bw_20260311_170151.bin`, frames 102–112).
### Write frame format — CRITICAL: minimal DLE stuffing
@@ -1805,7 +2282,7 @@ body) because writing a dial string may require DLE escaping for embedded contro
| Folder / File | Contents |
|---|---|
| `1-2-26/` | First SUB 5A BW TX capture — established 5A frame format (raw offset_hi, DLE-aware checksum). 10 frames verified. |
| `1-2-26/` | First SUB 5A BW TX capture — established 5A frame format (raw offset_hi, DLE-aware checksum). 10 frames verified. (⚠ model retracted 2026-10-26) |
| `3-11-26/raw_bw_20260311_170151.bin` | Full compliance write + event download (SUBs 68→83 confirmed, frames 102–112) |
| `3-31-26/` | Single-event download (148 BW / 147 S3 frames) — 1E/0A/0C/1F sequence confirmed (single event so token=0xFE appeared to work in either branch) |
| `4-2-26/` | Download-mode BW TX capture — POLL×3 requirement confirmed (frames 68-73 between 1F and first 5A) |
@@ -1817,7 +2294,7 @@ body) because writing a dial string may require DLE escaping for embedded contro
| `4-20-26/geo sensitivity/` | Geo sensitivity changes: 1.25 in/s (Sensitive), 10 in/s (Normal) |
| `4-20-26/call home settings/` | Call home config read/write captures |
| `4-27-26/` | BW "open 2sec waveform" + "copy event to disk" + paired SFM "seismo_dl" — first proof of 5× SFM over-read. STRT end_key field located. |
| **`5-1-26/comcheck/`** | **Triplet of captures that nailed the v0.14.0 walk:** SFM 3-sec download (`seismo_dl_…`), BW comms-check + 3-sec download (`bwcap3sec/`), BW second-event download + "Download All" (`raw_*_170945` / `_171216`). Confirmed: TERM frame formula across 3 events, metadata pages 0x1002/0x1004 are global session metadata, event-1 vs event-N chunk pattern split, WAVEHDR off=0x46 vs 0x2C disambiguates real events from boundaries. |
| **`5-1-26/comcheck/`** | **Triplet of captures that nailed the v0.14.0 walk:** SFM 3-sec download (`seismo_dl_…`), BW comms-check + 3-sec download (`bwcap3sec/`), BW second-event download + "Download All" (`raw_*_170945` / `_171216`). Confirmed: TERM frame formula across 3 events, metadata pages 0x1002/0x1004 are global session metadata (⚠ retracted 2026-10-26: event 1's chunks at 0x0200/0x0400), event-1 vs event-N chunk pattern split, WAVEHDR off=0x46 vs 0x2C disambiguates real events from boundaries. |
| **`5-1-26/comcheck/bwcap3sec/`** | **The byte-perfect reference for v0.14.3.** All 17 BW 5A request frames (probe, 2 metadata, 13 samples, TERM) reproduce byte-for-byte from SFM's framing helpers — including the `10 10 00` DLE-stuffed counter for sample @ 0x1000 that was the long-standing failure mode. |
| `5-4-26/` | BW MITM captures of "copy 3sec / 2sec / Download All" + paired SFM session (`seismo_dl_20260504_145701`) showing the +0x46 event-N probe bug producing 110-chunk runaway walk. Cross-references against 5-1-26 confirmed device behavior is identical. |
+21 -1
View File
@@ -1,4 +1,4 @@
# seismo-relay `v0.29.0`
# seismo-relay `v0.31.0`
A ground-up replacement for **Blastware** — Instantel's aging Windows-only
software for managing seismographs. Supports both the **MiniMate Plus
@@ -177,10 +177,25 @@ via a thread-safe `_LiveCache` (plain Python dict + `threading.Lock`):
| `POST` | `/device/monitor/start` | Sends SUB 0x96; immediately evicts status cache |
| `POST` | `/device/monitor/stop` | Sends SUB 0x97; immediately evicts status cache |
| `POST` | `/device/call_home` | Reads, patches specified fields, writes back to device |
| `GET` | `/device/settings` | Recording settings in the shared model, either series; serial required; never cached |
| `POST` | `/device/hangup` | Releases a held Series-4 line now; `{"hung_up": bool}` |
| `GET` | `/device/events?serial=` | Lists a unit's events, either series, each with an opaque `event_id` (`serial:key:timestamp`). A MiniMate list reads headers only (no bulk download), on the normal timeout, and gives `record_type: null` (its event record does not say waveform or histogram; not decoded yet). A lost walk reply fails the list rather than shortening it (a lost event-record reply still lists that event, without a timestamp) |
| `POST` | `/device/events/download?serial=&event_id=` | Downloads one event, checks it, and stores it in SFM's database; returns `db_event_id` (file at `GET /db/events/{db_event_id}/blastware_file`). A stale `event_id` (unit erased or wrapped since the list) gets **409** without downloading, for both series; an `event_id` from another unit gets **422**, before any I/O. An event already stored — by an earlier download, or by THOR's or Blastware's call-home watcher — returns its existing row and changes nothing (same `db_event_id`, `inserted: false`, `detail.already_stored: true`). The unit is busy for the whole download; other requests to it get 423 |
**Cache bypass** — All cached endpoints accept `?force=true` to skip the cache and
force a fresh read from the device.
**Serial-named requests (Series 3 and 4)** — `/device/info`, `/device/connect`,
`/device/monitor/status` and `/device/settings` accept `serial` (`UM...` = Series 4
Micromate, `BE...`/`BA...` = Series 3 MiniMate Plus) and return one shared model
for either series. Serial-named requests are **not cached** and ignore `force`.
Without `serial` the legacy Series-3 behaviour is unchanged. Any other `/device/*`
route given a `UM` serial answers **501** ("not supported for Series 4 yet"), and any
request that takes the legacy Series-3 path (no `serial`, or a `BE`/`BA` serial on a
route that does not take one) at an address holding a Series-4 line answers **409**
(use `POST /device/hangup` first). Series-4 lines are held open between requests, so
SFM must run a **single uvicorn worker**: locks and held lines are per process.
**Cache stats** — `GET /cache/stats` returns hit/miss counts and TTL info; `DELETE /cache/device`
clears the device cache immediately.
@@ -496,6 +511,11 @@ Use **com0com** or **VSPD** to create the virtual COM pair on Windows.
## Roadmap (Future)
> **Where it stands *today*** — an honest per-capability maturity assessment,
> what to rely on, known issues, and the gap to a real tool:
> [`docs/sfm_tool_status.md`](docs/sfm_tool_status.md). This section covers
> where it is *going*.
### Strategic direction — where this is going
seismo-relay is being built as a **suite of cooperating components**
+75
View File
@@ -177,6 +177,8 @@ class AchSession:
store: "WaveformStore",
clear_after_download: bool = False,
restart_monitoring: bool = False,
rescue_stop_monitoring: bool = False,
rescue_disable_ach: bool = False,
force_redownload: bool = False,
) -> None:
self.sock = sock
@@ -190,6 +192,9 @@ class AchSession:
self.store = store
self.clear_after_download = clear_after_download
self.restart_monitoring = restart_monitoring
# Rescue actions for a runaway unit — fired before the event walk.
self.rescue_stop_monitoring = rescue_stop_monitoring
self.rescue_disable_ach = rescue_disable_ach
# `force_redownload` tells this session to ignore ach_state and
# re-download every event currently on the device, regardless of any
# (key, timestamp) match. Useful as a manual override when state has
@@ -290,6 +295,41 @@ class AchSession:
root_logger.addHandler(fh)
try:
# ── Step 1.5: rescue actions ──────────────────────────────────────
# Fired BEFORE the event walk so a runaway unit is quieted as early
# in the session as possible. A unit whose geophone sits above the
# trigger threshold records back-to-back and, with ACH set to "after
# event recorded", re-dials every time — saturating its own firmware
# so it never services inbound requests. See
# docs/runbooks/wedged_unit_recovery.md.
#
# Each action is independently guarded: a failure here must not
# abort the download that follows.
if self.rescue_stop_monitoring or self.rescue_disable_ach:
rescue: dict = {"peer": self.peer, "ts": ts}
if self.rescue_stop_monitoring:
log.info("Step 1.5: RESCUE — stop monitoring (SUB 0x97)")
try:
client.stop_monitoring()
rescue["stop_monitoring"] = "ok"
log.info(" stop monitoring OK — device should stop recording")
except Exception as exc:
rescue["stop_monitoring"] = f"failed: {exc}"
log.error(" stop monitoring FAILED: %s", exc)
if self.rescue_disable_ach:
log.info("Step 1.5: RESCUE — disable auto call home (SUB 0x2C/0x7E/0x7F)")
try:
client.set_call_home_config(auto_call_home_enabled=False)
rescue["disable_ach"] = "ok"
log.info(" disable ACH OK — unit should stop calling home")
except Exception as exc:
rescue["disable_ach"] = f"failed: {exc}"
log.error(" disable ACH FAILED: %s", exc)
_save_json(session_dir / "rescue.json", rescue)
# ── Step 2: device info ───────────────────────────────────────────
device_info = None
if not self.events_only:
@@ -747,6 +787,13 @@ def serve(args: argparse.Namespace) -> None:
print(f" Max events per session: {max_ev if max_ev else 'unlimited'}")
print(f" Clear device after download: {'YES' if args.clear_after_download else 'no'}")
print(f" Restart monitoring after download: {'YES' if args.restart_monitoring else 'no'}")
_stop_mon = args.stop_monitoring or args.rescue
_dis_ach = args.disable_ach or args.rescue
print(f" RESCUE stop monitoring on connect: {'YES' if _stop_mon else 'no'}")
print(f" RESCUE disable auto call home: {'YES' if _dis_ach else 'no'}")
if _stop_mon and args.restart_monitoring:
print(" !! --restart-monitoring will re-start the unit after download,")
print(" undoing --stop-monitoring. Drop one of them.")
print(f" Force re-download all (ignore state): {'YES' if args.force_redownload_all else 'no'}")
print(f"{'='*60}")
print(f"\n Point your test unit's ACEmanager call-home settings to:")
@@ -788,6 +835,8 @@ def serve(args: argparse.Namespace) -> None:
store=store,
clear_after_download=args.clear_after_download,
restart_monitoring=args.restart_monitoring,
rescue_stop_monitoring=args.stop_monitoring or args.rescue,
rescue_disable_ach=args.disable_ach or args.rescue,
force_redownload=args.force_redownload_all,
)
t = threading.Thread(target=session.run, daemon=True, name=f"ach-{peer}")
@@ -862,6 +911,32 @@ def parse_args() -> argparse.Namespace:
"DCD on disconnect — without this the unit stays idle after a call-home."
),
)
p.add_argument(
"--stop-monitoring",
action="store_true",
default=False,
help=(
"RESCUE: send SUB 0x97 (stop monitoring) immediately after the "
"handshake, before any event download. Use on a unit that is "
"recording back-to-back because of a stuck-triggered geophone."
),
)
p.add_argument(
"--disable-ach",
action="store_true",
default=False,
help=(
"RESCUE: disable Auto Call Home on the device (SUB 0x2C read → "
"0x7E write → 0x7F confirm) immediately after the handshake. The "
"unit stops dialing out until ACH is explicitly re-enabled."
),
)
p.add_argument(
"--rescue",
action="store_true",
default=False,
help="Shorthand for --stop-monitoring --disable-ach.",
)
p.add_argument(
"--clear-after-download",
action="store_true",
+398
View File
@@ -0,0 +1,398 @@
#!/usr/bin/env python3
"""
mm_ach_server.py — inbound Auto Call Home server for Micromate (Series IV).
**Read-only.** It identifies the unit, reads its state and setups, and walks the
event chain. It does not erase, does not write, does not start or stop
monitoring, and downloads nothing unless asked. Series III's `ach_server.py`
has "rescue actions" that quiet a runaway unit; those are deliberately absent
here, because no command has ever been originated against a unit by this project
and an inbound session is the worst place to break that.
What this is for
----------------
The inbound call-home session is the last unmapped part of the Series IV
protocol.
⚠ **No Micromate has ever been observed calling home.** The 72 `ach_inbound_*`
sessions in `bridges/captures/` are **MiniMate Plus**, and the Series III setup
does not automatically transfer. What we have for Series IV is prior, not
observation:
* The THOR manual §6.2 and the firmware's own strings
(`CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING`, `Call Home Deleting
Events`) say the unit dials in and then **waits to be told what to do** —
server-driven, the same shape as Series III's pull model.
* UM12947's `0x2C` dial string reads literally `"RADIO RING"`, which is modem
*answer* vocabulary rather than a destination. With the RV50 debug string
`ATQ1 ATE0 ATS0=2 … RADIO RING` — `ATS0=2` being auto-answer-after-2-rings —
that reads as the unit configuring the modem to **accept** calls, i.e. the
call-*up* path. Which suggests the ACH destination lives in the **modem**,
as it does for Series III.
**If both priors hold, this file is just `MicromateClient` on an inbound socket
and the unknown evaporates.** But there is a specific way it can fail:
⚠ **Those AT strings prove the Micromate talks to the modem over serial.** If it
drives an AT dial for call-home, that exchange happens on the **serial link**,
where a TCP listener sees nothing whatsoever. So a null result here is
informative but ambiguous — it means *either* the trigger did not fire *or* the
interesting part is happening somewhere this tool cannot watch. **If nothing
arrives, the next step is a serial-level capture between the unit and the modem,
not more fiddling with this server.**
**The one question that matters is push vs pull**, and it cannot be answered by
sniffing — only by connecting and keeping quiet. So this server **says nothing
for `--grace` seconds** after accepting. If bytes arrive in that window the unit
speaks first (push) and the server reports exactly what it sent. If the window
passes in silence, it is pull, and the normal handshake follows.
Setup
-----
1. Run this where the unit can reach it:
python3 bridges/mm_ach_server.py --port 12345
2. Point the call-home destination at this machine. **For Series III that
lived in the MODEM's config (ACEmanager), not in the seismograph** — so try
AirLink OS first. If the RX55 can be told to open an outbound TCP session
to `<your IP>:12345` on serial activity, nothing on the instrument needs to
change, which is much the better outcome.
If it has to come from the unit instead, its `SUB 0x2C` call-home block
holds a 40-byte dial string — but **writing that is THOR's job, not ours.**
3. Trigger a call. A scheduled time is the controllable option: repeatable,
needs no monitoring and no thumping. An event-triggered call is the more
interesting session, because it shows how an event gets offered.
4. Watch. Every frame is decoded as it arrives.
⚠ Use a bench unit. Changing a call-home destination means a unit stops
reporting to THOR until it is changed back.
Output per session, in the layout `scratch/mm_frame_parse.py` reads directly:
bridges/captures/mm_ach_<ts>/
raw_bw_<ts>.bin us → unit
raw_s3_<ts>.bin unit → us
session_<ts>.log
session.json what we learned, including push-vs-pull
"""
from __future__ import annotations
import argparse
import datetime
import json
import logging
import socket
import sys
import threading
import time
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
from micromate.client import MicromateClient # noqa: E402
from micromate.framing import MicromateFrameParser # noqa: E402
from micromate.protocol import ProtocolError # noqa: E402
from minimateplus.transport import SocketTransport # noqa: E402
log = logging.getLogger("mm_ach")
DEPTHS = ("identify", "state", "events", "download")
# Strings the MODEM puts on the wire, which are not the unit talking.
#
# `CLAUDE.md` already records that an RV50/RV55 "sends \r\nRING\r\n\r\nCONNECT\r\n
# over TCP to the caller even with Quiet Mode enabled". An RX55 on AirLink OS
# says `RADIO RING` instead, space-padded and newline-separated. Observed
# 2026-10-14 from UM12947's modem: four of them and **no CONNECT**.
#
# ⚠ The absence of CONNECT is the useful part. RING means the modem is ringing
# the serial device; CONNECT means something answered. Rings without a CONNECT,
# and no answer to POLL, means the TCP side is fine and the UNIT is not on the
# other end of the serial link.
_MODEM_CHATTER = (b"RADIO RING", b"RING", b"CONNECT", b"NO CARRIER", b"BUSY",
b"NO ANSWER", b"ERROR", b"OK")
class Session:
"""One inbound call. Captures every byte; decides push vs pull first."""
def __init__(self, sock: socket.socket, peer: str, args) -> None:
self.sock, self.peer, self.args = sock, peer, args
self.ts = datetime.datetime.now().strftime("%Y%m%d_%H%M%S")
self.found: dict = {"peer": peer, "started": self.ts}
self._rx: list[bytes] = []
self._tx: list[bytes] = []
self._rx_fh = self._tx_fh = None
# ── byte taps ─────────────────────────────────────────────────────────────
def _tap(self, transport) -> None:
"""Mirror every byte, buffered until we know this is a real unit."""
orig_read, orig_write = transport.read, transport.write
def read(n: int) -> bytes:
data = orig_read(n)
if data:
(self._rx_fh.write(data), self._rx_fh.flush()) if self._rx_fh \
else self._rx.append(data)
return data
def write(data: bytes) -> None:
orig_write(data)
if data:
(self._tx_fh.write(data), self._tx_fh.flush()) if self._tx_fh \
else self._tx.append(data)
transport.read, transport.write = read, write
def _open_capture(self) -> Path:
"""Create the session directory — only once we trust the peer.
A port scanner should leave nothing on disk.
"""
d = Path(self.args.output) / f"mm_ach_{self.ts}"
d.mkdir(parents=True, exist_ok=True)
# Named raw_bw/raw_s3 so scratch/mm_frame_parse.py reads the pair as-is.
self._tx_fh = open(d / f"raw_bw_{self.ts}.bin", "wb")
self._rx_fh = open(d / f"raw_s3_{self.ts}.bin", "wb")
for c in self._tx:
self._tx_fh.write(c)
for c in self._rx:
self._rx_fh.write(c)
self._tx_fh.flush()
self._rx_fh.flush()
self._tx.clear()
self._rx.clear()
return d
# ── the experiment ────────────────────────────────────────────────────────
def _listen_first(self, transport) -> bytes:
"""Say nothing for `--grace` seconds — unless a RING arrives.
Originally this just answered "does the unit speak first?". THOR's ACH
log (2026-10-14) made the question sharper: on seeing `RADIO RING` it
replies in **36 ms**, and with `ReadSerialNumber`, not `POLL`.
We were doing neither — sitting silent for the full 8 s and then sending
POLL. The unit may well have given up long before we spoke. So the
grace window now **ends the moment a ring is seen**, and the caller
answers it the way THOR does.
"""
print(f" listening in silence for up to {self.args.grace:.1f} s "
f"(ends early on a RING)...")
deadline = time.monotonic() + self.args.grace
got = bytearray()
while time.monotonic() < deadline:
chunk = transport.read(4096)
if chunk:
got += chunk
if b"RING" in got:
print(f" RING seen after "
f"{self.args.grace - (deadline - time.monotonic()):.2f} s"
f" — answering immediately, as THOR does")
return bytes(got)
else:
time.sleep(0.02)
return bytes(got)
def run(self) -> None:
print(f"\n=== inbound from {self.peer} at {self.ts} ===")
transport = SocketTransport(self.sock, peer=self.peer)
self._tap(transport)
unsolicited = self._listen_first(transport)
self.found["push"] = bool(unsolicited)
self.found["unsolicited_bytes"] = len(unsolicited)
if unsolicited:
print(f" ** PUSH ** — the unit sent {len(unsolicited)} B unprompted")
print(f" hex : {unsolicited[:64].hex(' ')}")
txt = "".join(chr(c) if 32 <= c < 127 else "." for c in unsolicited[:64])
print(f" ascii : |{txt}|")
hits = [c.decode() for c in _MODEM_CHATTER if c in unsolicited]
if hits:
rings = unsolicited.count(b"RING")
print(f" *** MODEM CHATTER, not the unit: {hits} ***")
self.found["modem_chatter"] = hits
self.found["ring_count"] = rings
if rings and b"CONNECT" not in unsolicited:
print(f" *** {rings} RING(s) and NO CONNECT. ***")
print(" The modem is ringing the serial device and nothing")
print(" is answering. TCP is fine; the UNIT is not on the")
print(" other end of the serial link. Check, in order:")
print(" 1. is the unit cabled to the modem at all?")
print(" 2. cable chipset -- FTDI (0403) or CDC-ACM only,")
print(" never Prolific (067b)")
print(" 3. cold-boot the unit WITH the cable attached;")
print(" its USB-A host port only enumerates at power-on")
self.found["diagnosis"] = "rings without connect: unit not on serial"
frames = MicromateFrameParser().feed(unsolicited)
if frames:
for f in frames:
print(f" frame : SUB=0x{f.sub:02x} "
f"(answers 0x{f.request_sub:02x}) {len(f.data)} B data, "
f"flags=0x{f.flags:02x}, chk "
f"{'ok' if f.checksum_valid else 'BAD'}")
self.found["unsolicited_subs"] = [f"0x{f.sub:02x}" for f in frames]
else:
print(" frame : none parsed — not a response frame. Could be")
print(" a banner (series III sends 'Operating System'")
print(" on cold boot) or a greeting we have not seen.")
else:
print(" ** PULL ** — silence. The unit is waiting to be driven,")
print(" same as series III. Running the normal handshake.")
# From here on it is the ordinary client, which is the point.
mm = MicromateClient(transport, recv_timeout=self.args.timeout)
try:
if b"RING" in unsolicited:
# ⚠ Answer a ring the way THOR does: SERIAL first, not POLL.
# THOR's ACH log shows ReadSerialNumber 36 ms after detecting the
# ring -- it is identifying which unit rang before doing anything
# else. Our POLL-after-8-seconds may simply have been too late
# and the wrong question.
print(" answering the ring with SERIAL (THOR's first move)...")
serial = _cstring(_content(mm.protocol.read_serial()))
print(f" *** THE UNIT ANSWERED: {serial} ***")
self.found["answered_ring"] = True
self.found["ring_serial"] = serial
info = mm.connect()
except ProtocolError as e:
print(f" handshake FAILED: {type(e).__name__}: {e}")
if not unsolicited:
print(" Nothing unprompted AND no answer to POLL — so this is")
print(" neither push nor pull as we understand it. The raw")
print(" capture is the thing to look at; keep it.")
self._finish(self._open_capture())
return
d = self._open_capture()
print(f" {info}")
self.found["device"] = {
"serial": info.serial, "model": info.model,
"firmware_line": info.firmware_line, "monitoring": info.monitoring,
"active_setup": info.active_setup,
}
try:
if DEPTHS.index(self.args.depth) >= DEPTHS.index("state"):
st = mm.get_state()
print(f" {st}")
self.found["state"] = {
"monitoring": st.monitoring,
"device_time": st.device_time.isoformat() if st.device_time else None,
"battery_volts": st.battery_volts,
"memory_free_bytes": st.memory_free_bytes,
}
self.found["setups"] = mm.list_setups()
print(f" {len(self.found['setups'])} setups")
if DEPTHS.index(self.args.depth) >= DEPTHS.index("events"):
refs = mm.list_events()
print(f" {len(refs)} events")
self.found["events"] = []
for r in refs:
print(f" {r}")
self.found["events"].append({
"uid": r.uid, "key": r.key_hex, "size": r.size,
"type": r.record_type, "filename": r.filename,
"timestamp": r.timestamp.isoformat() if r.timestamp else None,
"pvs_ips": r.peak_vector_sum_ips,
})
if self.args.depth == "download":
# Bounded on purpose: an unknown session is a poor place to
# discover that a 70 KB pull takes 30 s and the unit hung up.
for r in refs[: self.args.max_events]:
blob = mm.download_event(r)
out = d / (r.filename or f"{r.key_hex}.bin")
out.write_bytes(blob)
print(f" saved {out.name} ({len(blob)} B)")
except ProtocolError as e:
print(f" session ended early: {type(e).__name__}: {e}")
self.found["error"] = f"{type(e).__name__}: {e}"
self._finish(d)
def _finish(self, d: Path) -> None:
for fh in (self._rx_fh, self._tx_fh):
if fh:
fh.close()
(d / "session.json").write_text(json.dumps(self.found, indent=2))
try:
self.sock.close()
except OSError:
pass
print(f" saved {d}")
print(f" parse with: python3 scratch/mm_frame_parse.py {d}")
def main() -> int:
ap = argparse.ArgumentParser(
description=__doc__, formatter_class=argparse.RawDescriptionHelpFormatter
)
ap.add_argument("--port", type=int, default=12345)
ap.add_argument("--bind", default="0.0.0.0")
ap.add_argument("--output", default="bridges/captures")
ap.add_argument("--timeout", type=float, default=30.0,
help="per-command receive timeout; generous, because an "
"inbound cellular session is the slow case")
ap.add_argument("--grace", type=float, default=5.0,
help="seconds to stay SILENT after accepting, to see whether "
"the unit speaks first. This is the experiment; do not "
"set it to 0 on a first run.")
ap.add_argument("--depth", choices=DEPTHS, default="events",
help="how far to take the session. 'events' walks the chain "
"without downloading (default); 'download' also fetches "
"events, which on cellular is ~0.21 s + bytes/2350 each")
ap.add_argument("--max-events", type=int, default=3,
help="with --depth download, how many to fetch")
ap.add_argument("--once", action="store_true",
help="exit after the first session instead of listening on")
a = ap.parse_args()
# ⚠ Without this, stdout is block-buffered whenever it is not a terminal,
# so the live session commentary sits in a buffer and the log looks EMPTY
# while a call is happening. That cost a confusing few minutes on the first
# real call-in: the session was on disk but nothing was on screen.
try:
sys.stdout.reconfigure(line_buffering=True)
except AttributeError: # pragma: no cover - py<3.7
pass
logging.basicConfig(level=logging.INFO,
format="%(asctime)s %(levelname)-7s %(message)s")
srv = socket.socket(socket.AF_INET, socket.SOCK_STREAM)
srv.setsockopt(socket.SOL_SOCKET, socket.SO_REUSEADDR, 1)
srv.bind((a.bind, a.port))
srv.listen(5)
print(f"\nMicromate ACH server on {a.bind}:{a.port} (READ-ONLY)")
print(f" depth={a.depth} grace={a.grace}s timeout={a.timeout}s")
print(" waiting for a unit to call in. Ctrl-C to stop.\n")
try:
while True:
sock, addr = srv.accept()
peer = f"{addr[0]}:{addr[1]}"
s = Session(sock, peer, a)
if a.once:
s.run()
return 0
threading.Thread(target=s.run, daemon=False).start()
except KeyboardInterrupt:
print("\nstopped")
return 0
finally:
srv.close()
if __name__ == "__main__":
raise SystemExit(main())
+476
View File
@@ -0,0 +1,476 @@
#!/usr/bin/env python3
"""
mm_client_check.py — exercise the Micromate read client against a real unit.
**Read-only.** It sends POLL, SERIAL, state, monitor status, the setup walk and
(optionally) one event download. It never writes, never erases, never starts or
stops monitoring.
Why it exists
-------------
`micromate/{framing,protocol,client}.py` are verified against captures taken
**over USB**, on **one firmware line** (`11.0CB`). Two things that cannot be
verified that way:
* **the modem path.** An RX55/RV55 bridges serial to TCP transparently, but
it buffers up to ~1 s before forwarding, so a single logical response can
arrive as many small reads. The client reads to frame completion rather
than using idle-gap detection, which should be strictly more robust — but
"should be" is the point of this script.
* **the other firmware line.** `11.0BD` reports `flags = 0x03`, a shorter
model string, and a `SUB 0x1C` block 4 bytes longer. Inferred from a
2026-09-23 sweep; **confirmed on UM20147 2026-09-30** (forward offsets read
a correct battery and clock).
Run it over both paths and diff the two reports. Anything that differs beyond
timings is a finding.
Usage
-----
# over the modem
python3 bridges/mm_client_check.py 63.45.161.30:9034
# over USB / direct serial
python3 bridges/mm_client_check.py /dev/ttyACM0 --baud 115200
# include one event download (still read-only)
python3 bridges/mm_client_check.py <target> --download
⚠ These modems bridge ONE TCP session to serial at a time. If THOR holds the
unit, this will connect and then see nothing — that is contention, not a fault.
`bridges/mm_probe.py` explains that case; disconnect THOR first.
"""
from __future__ import annotations
import argparse
import errno
import os
import select
import sys
import termios
import time
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
from micromate.client import MicromateClient, _content # noqa: E402
from micromate.protocol import CHUNK_SIZE, ProtocolError # noqa: E402
from minimateplus.transport import TcpTransport # noqa: E402
class StdlibSerial:
"""Raw serial on stdlib `termios` — no pyserial.
`minimateplus.SerialTransport` needs pyserial, and a bench host is whatever
is to hand. On a PEP 668 distro (Mint 22, Ubuntu 24.04, Debian 12) a plain
`pip install pyserial` is refused outright, so a diagnostic that depends on
it is one you cannot run at the moment you need it. `bridges/mm_link.py`
and `scratch/fake_unit.py` already take this approach; this is the same
~30 lines, and it means the tool runs on a stock Python 3 anywhere.
Not a general replacement for SerialTransport — no flow control, no
parity options, Linux/macOS only. Enough for a Micromate, which is 8N1
with no handshaking.
"""
_BAUD = {9600: termios.B9600, 19200: termios.B19200, 38400: termios.B38400,
57600: termios.B57600, 115200: termios.B115200}
def __init__(self, path: str, baud: int = 115200) -> None:
if baud not in self._BAUD:
raise ValueError(f"unsupported baud {baud}; pick from {sorted(self._BAUD)}")
self.path, self.baud, self.fd = path, baud, None
def connect(self) -> None:
if self.fd is not None:
return
self.fd = os.open(self.path, os.O_RDWR | os.O_NOCTTY | os.O_NONBLOCK)
a = termios.tcgetattr(self.fd)
a[0] = a[1] = a[3] = 0 # raw in/out, non-canonical
a[2] = termios.CS8 | termios.CREAD | termios.CLOCAL # 8N1, ignore modem lines
a[4] = a[5] = self._BAUD[self.baud]
a[6] = list(a[6])
a[6][termios.VMIN] = 0
a[6][termios.VTIME] = 0
termios.tcsetattr(self.fd, termios.TCSANOW, a)
termios.tcflush(self.fd, termios.TCIOFLUSH)
def disconnect(self) -> None:
if self.fd is not None:
os.close(self.fd)
self.fd = None
def is_connected(self) -> bool:
return self.fd is not None
def read(self, n: int) -> bytes:
if self.fd is None:
return b""
r, _, _ = select.select([self.fd], [], [], 0.05)
if not r:
return b""
try:
return os.read(self.fd, n)
except OSError as e:
if e.errno in (errno.EAGAIN, errno.EWOULDBLOCK):
return b""
raise
def write(self, data: bytes) -> None:
if self.fd is None:
raise OSError("port is not open")
while data:
data = data[os.write(self.fd, data):]
class _Timed:
"""Count bytes and time each read, so the two transports can be compared.
With `capture`, also writes the raw byte streams to a `raw_bw_*` /
`raw_s3_*` pair in the layout `scratch/mm_frame_parse.py` already reads --
so a run on an unfamiliar unit can be turned into test fixtures without
setting up a relay.
"""
def __init__(self, inner, capture: str | None = None) -> None:
self._inner = inner
self.reads = 0
self.bytes_in = 0
self.bytes_out = 0
self._bw = self._s3 = None
if capture:
stamp = time.strftime("%Y%m%d_%H%M%S")
d = Path(capture)
d.mkdir(parents=True, exist_ok=True)
self.bw_path = d / f"raw_bw_{stamp}_mm_client_check.bin"
self.s3_path = d / f"raw_s3_{stamp}_mm_client_check.bin"
self._bw = open(self.bw_path, "wb")
self._s3 = open(self.s3_path, "wb")
def close_capture(self) -> None:
for f in (self._bw, self._s3):
if f:
f.close()
def connect(self):
return self._inner.connect()
def disconnect(self):
return self._inner.disconnect()
def is_connected(self):
return self._inner.is_connected()
def write(self, data: bytes):
self.bytes_out += len(data)
if self._bw:
self._bw.write(data); self._bw.flush()
return self._inner.write(data)
def read(self, n: int) -> bytes:
chunk = self._inner.read(n)
if chunk:
self.reads += 1
self.bytes_in += len(chunk)
if self._s3:
self._s3.write(chunk); self._s3.flush()
return chunk
# ⚠ HYPOTHESIS, 6 events. content[11] of the 0x0C record separated 4 waveforms
# from 2 histograms cleanly and was constant within each group. A 4/2 split is
# thin evidence for a byte that could be anything, so _decode() below does NOT
# trust it -- it tries the other suffix on failure and says when the guess was
# wrong. The protocol reference states no type field is known; this may be it.
_TYPE_BYTE = 11
_TYPES = {0x07: ".IDFW", 0x08: ".IDFH"}
def _event_type(record: bytes) -> str:
if len(record) <= _TYPE_BYTE:
return "?"
b = record[_TYPE_BYTE]
return {0x07: "waveform", 0x08: "histogram"}.get(b, f"unknown(0x{b:02x})")
def _decode(blob: bytes, key: bytes, record: bytes) -> None:
"""Decode the downloaded bytes, proving they are a real event file.
read_idf_file() picks waveform vs histogram from the FILENAME SUFFIX, and a
wire download has no filename -- so the suffix has to come from somewhere.
This tries the 0x0C type byte first and the other suffix second; getting a
decode either way proves the chunk assembly, and which one worked is itself
the finding.
"""
import tempfile
from micromate.idf_file import read_idf_file
guess = _TYPES.get(record[_TYPE_BYTE] if len(record) > _TYPE_BYTE else -1, ".IDFW")
order = [guess] + [e for e in (".IDFW", ".IDFH") if e != guess]
for n, ext in enumerate(order):
with tempfile.NamedTemporaryFile(suffix=ext, delete=False) as f:
f.write(blob)
tmp = f.name
try:
res = read_idf_file(tmp)
samples = sum(len(v) for v in getattr(res, "samples", {}).values())
note = "" if n == 0 else f" *** the 0x0C type byte guessed {guess} — WRONG ***"
print(f" decoded OK as {ext}: {samples} samples{note}")
os.unlink(tmp)
return
except Exception as e:
last = f"{ext}: {type(e).__name__}: {e}"
finally:
if os.path.exists(tmp):
os.unlink(tmp)
print(f" decode failed BOTH ways — last: {last}")
out = Path(f"./{key.hex()}.bin")
out.write_bytes(blob)
print(f" saved to {out} for offline analysis")
def _select(refs, which: str):
"""Pick which events `--download` fetches."""
which = which.strip().lower()
if which == "first":
return refs[:1]
if which == "all":
return refs
if which == "largest":
return [max(refs, key=lambda r: r.size)]
return [r for r in refs if r.key_hex.lower() == which]
def _setup_lines(s) -> list[str]:
"""A decoded setup, laid out the way the unit's own menus group it."""
def sensors(geo: bool, mic: bool) -> str:
return " + ".join(n for n, on in (("geophones", geo), ("mic", mic)) if on) or "none"
stop = f"Auto, after {s.auto_stop_after_s} s quiet" if s.auto_record_stop else "Fixed"
if s.mic_type == "linear":
mic = f"linear, trigger {s.mic_trigger_db:.1f} dB ({s.mic_trigger_psi:.5f} psi)"
else:
mic = s.mic_type
sd = (f"on: {s.distance_ft:.1f} ft, {s.charge_weight_lb:.1f} lb"
+ (f" -> {s.scaled_distance:.2f}" if s.scaled_distance else "")
if s.scaled_distance_enabled else "off")
return [
f"record mode {s.record_mode_name}",
f"sample rate {s.sample_rate} sps",
f"histogram interval {s.histogram_interval_s} s",
f"record time {s.record_time_s:g} s stop: {stop}",
f"pre-trigger {s.pretrigger_s:g} s",
f"sensors on {sensors(s.geophones_active, s.mic_active)}",
f"trigger on {sensors(s.trigger_on_geophones, s.trigger_on_mic)}",
"geophone trigger " + " / ".join(f"{v:.3f}" for v in s.geo_trigger_ips) + " in/s",
f"microphone {mic}",
f"job number {s.job_number} ({'on' if s.job_number_enabled else 'off'})",
f"scaled distance {sd}",
*(f"note {k:<15}{v!r}" for k, v in s.notes.items()),
]
def step(label: str, fn, show=None):
"""Run one read, report how long it took and what it returned."""
t0 = time.monotonic()
try:
value = fn()
except Exception as e:
print(f" {label:.<26} FAILED {type(e).__name__}: {e}")
return None
ms = 1000 * (time.monotonic() - t0)
shown = value if isinstance(value, str) else repr(value)
if isinstance(value, list):
shown = f"{len(value)} entries"
if show:
shown = show(value)
print(f" {label:.<26} {ms:7.0f} ms {shown}")
return value
def main() -> int:
ap = argparse.ArgumentParser(
description=__doc__, formatter_class=argparse.RawDescriptionHelpFormatter
)
ap.add_argument("target", help="host:port for TCP, or a serial device path")
ap.add_argument("--baud", type=int, default=115200,
help="serial only; the USB-A/FTDI path runs at 115200. "
"Ignored by the USB-B 'PC' port, which is CDC-ACM "
"and negotiates its own rate.")
ap.add_argument("--timeout", type=float, default=10.0)
ap.add_argument("--download", action="store_true",
help="also walk the event chain and download (read-only)")
ap.add_argument("--event", default="first", metavar="WHICH",
help="which event --download fetches: a key in hex "
"(e.g. 055d4a83), 'first', 'largest', or 'all'. "
"'largest' is the one worth running on an unfamiliar "
"unit -- it is what exercises offsets past 64 KB.")
ap.add_argument("--capture", metavar="DIR",
help="also write a raw_bw_*/raw_s3_*.bin pair to DIR, so "
"this run can become a test fixture. Worth doing on "
"any unit whose firmware line is new to us.")
ap.add_argument("--lenient", action="store_true",
help="do not raise on a bad checksum — for diagnosis only")
a = ap.parse_args()
if ":" in a.target and not Path(a.target).exists():
host, _, port = a.target.rpartition(":")
inner = TcpTransport(host, int(port), connect_timeout=a.timeout)
path = f"TCP {host}:{port}"
else:
inner = StdlibSerial(a.target, baud=a.baud)
path = f"serial {a.target} @ {a.baud}"
transport = _Timed(inner, capture=a.capture)
mm = MicromateClient(transport, recv_timeout=a.timeout,
strict_checksums=not a.lenient)
print(f"\n{path} (read-only: POLL, SERIAL, state, status, setups)\n")
t0 = time.monotonic()
try:
mm.open()
except OSError as e:
print(f" connect.................... FAILED {e}")
return 2
print(f" {'connect':.<26} {1000*(time.monotonic()-t0):7.0f} ms")
try:
info = step("connect() identity", mm.connect)
if info is None:
print("\n Nothing answered. If the port opened but no frame came back,")
print(" check it is actually a Micromate and not another CDC-ACM device —")
print(" /dev/ttyACM* numbering shifts when anything else is plugged in.")
print(" `ls -l /dev/serial/by-id/` names each device and is stable.")
return 3
if info:
print(f" serial={info.serial} model={info.model} "
f"fw={info.firmware_line} monitoring={info.monitoring}")
print(f" active setup={info.active_setup!r}")
if info.firmware_line == "thor":
print(" (11.0BD / Thor line: 0x1C is 4 B longer -- read forward, "
"confirmed 2026-09-30)")
state = step("get_state()", mm.get_state)
if state:
print(f" {state}")
if state.battery_volts and not 2.5 < state.battery_volts < 9.0:
print(f" *** battery {state.battery_volts} V is impossible — "
f"this is the from-the-end offset bug. ***")
if state.device_time is None:
print(" *** device clock did not decode — dump raw below. ***")
print(f" raw 0x1C content: {_content(state.raw).hex(' ')}")
setup = step("get_setup()", mm.get_setup, show=lambda s: f"{s.name} (checksum ok)")
if setup:
print(" check each line against the unit's screen:")
for line in _setup_lines(setup):
print(f" {line}")
setups = step("list_setups()", mm.list_setups)
if setups:
print(f" first={setups[0]!r} last={setups[-1]!r}")
# ── SUB 0x06: event count, and (likely) the monitor-log count ─────
# content[0:4] is the event count: 3/3 against the chain walk, and THOR's
# own ReadEventRecordCount agrees. content[4:8] was once recorded as "a
# constant 9" -- it read 47 during the 10-14 ACH session against THOR's
# "Monitor Log count: 45", so it is very likely the monitor-log count.
# Still graded a strong candidate, not settled (reference, 10-14).
claimed = None
raw06 = step("0x06 storage range", mm.protocol.read_storage_range)
if raw06:
c = _content(raw06)
claimed = int.from_bytes(c[0:4], "big")
print(f" content[0:4] = {claimed} <- event count")
print(f" content[4:8] = {int.from_bytes(c[4:8],'big')} "
f"<- likely the monitor-log count (strong candidate)")
if a.download:
print("\n event chain (read-only), via MicromateClient:")
t1 = time.monotonic()
refs = mm.list_events() # walks to the sentinel
walk = time.monotonic() - t1
print(f" {len(refs)} events in {walk:.1f} s "
f"({walk/max(len(refs),1):.2f} s each, 3 round trips per event)")
if claimed is not None:
verdict = ("✓ AGREES" if claimed == len(refs)
else f"✗ DISAGREES (0x06 said {claimed})")
print(f" 0x06 count vs chain length: {verdict}")
for ref in refs:
print(f" {ref}")
print(f" would be filed as {ref.filename}")
if refs:
wanted = _select(refs, a.event)
if not wanted:
print(f"\n --event {a.event!r} matched nothing")
else:
print(f"\n download ({len(wanted)} of {len(refs)}, "
f"THOR's interleaved order):")
want_keys = {r.key_hex for r in wanted}
# iter_events() walks the chain; download only the selected
# events, at the cursor position THOR would be at.
for ref in mm.iter_events():
if ref.key_hex not in want_keys:
continue
# ⚠ Use the size actually requested. This printed
# `size // 1024` -- THOR's chunk size -- while the
# download used the 16 KB default, so it reported 71
# requests for a walk that made 5. A diagnostic that
# misreports what it did is worse than one that says
# nothing, and this one nearly had me reading a working
# 16 KB download as a broken 1 KB one.
n_chunks = -(-ref.size // CHUNK_SIZE)
note = (" <- past 64 KB, carries into params[1]"
if ref.size > 0x10000 else "")
t1 = time.monotonic()
try:
result = mm.get_event(ref) # verify=True
except Exception as e:
print(f" {ref.key_hex} {ref.size:7} B "
f"FAILED {type(e).__name__}: {e}")
continue
dt = max(time.monotonic() - t1, 1e-6)
n = sum(len(v) for v in getattr(result, "samples", {}).values())
err = mm.decode_error(ref, result)
check = ("PVS %+.4f%%" % (100 * err) if err is not None
else "PVS n/a (histogram)")
print(f" {ref.key_hex} {ref.record_type:9} "
f"{ref.size:7} B {n_chunks:3} req @ {CHUNK_SIZE} B "
f"{dt:5.1f} s {n:6} samples {check}{note}")
except ProtocolError as e:
print(f"\n ABORTED {type(e).__name__}: {e}")
return 3
finally:
mm.close()
transport.close_capture()
if a.capture:
print(f"\n capture written:\n {transport.bw_path}\n {transport.s3_path}")
print(" parse it with: python3 scratch/mm_frame_parse.py "
f"{transport.bw_path} {transport.s3_path}")
elapsed = time.monotonic() - t0
print(f"\n transport: {transport.reads} reads, "
f"{transport.bytes_in} B in, {transport.bytes_out} B out, "
f"{elapsed:.1f} s total")
print(" Measured 2026-09-29, UM12947, same unit both ways:")
print(" USB-B (CDC-ACM) 83 reads list_setups 0.46 s download 394 KiB/s")
print(" RX55 (TCP) 36 reads list_setups 16.05 s download 1.6 KiB/s")
print(" The modem needs FEWER reads, not more -- it buffers ~1 s and then")
print(" forwards one large segment, where CDC-ACM delivers many small ones.")
print(" Cellular cost, measured: ~0.21 s per request + ~2,350 B/s.")
print(" So STATUS work is round-trip bound (minimise commands) but a")
print(" DOWNLOAD is throughput bound -- 16 KB chunks save ~30% on a large")
print(" event, not 14x. An earlier note claiming cost was independent of")
print(" payload was fitted only to sub-1 KB responses.\n")
return 0
if __name__ == "__main__":
raise SystemExit(main())
+91
View File
@@ -0,0 +1,91 @@
#!/usr/bin/env python3
"""Dry run a Micromate write against a live unit: do the reads, print the plan.
Sends READS only. The write frames are built from the unit's own blocks and
printed for review -- step 1 of the bench protocol for every first live write
(parity spec, Testing). The protocol's opcode gate refuses every write SUB on
this connection, so nothing else can go out even by mistake.
sg dialout -c ".venv/bin/python bridges/mm_dry_run.py /dev/ttyACM0 call-home-off"
.venv/bin/python bridges/mm_dry_run.py --host 10.0.0.5 --tcp-port 9034 setup-rewrite
The JSON carries a `reads` block (length of each block read, and for
setup-rewrite the blocks themselves in hex) so the plan can be checked against
what the unit actually said.
⚠ `0x1A` reads the keypad's edit buffer live. A setup read taken while someone
is in the unit's menu includes their unsaved edits, and pushing that plan would
commit them.
⚠ The setup-rewrite JSON embeds the unit's whole `0x1A` block (job number,
notes), so do not paste it anywhere public.
"""
from __future__ import annotations
import argparse
import json
import sys
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
from micromate.client import CONTENT, MicromateClient # noqa: E402
from micromate.writes import ( # noqa: E402
plan_call_home_enabled, plan_setup_push, plan_start_monitoring, plan_stop_monitoring,
)
from minimateplus.transport import SerialTransport, TcpTransport # noqa: E402
ACTIONS = ("start", "stop", "call-home-on", "call-home-off", "setup-rewrite")
def _content(data: bytes) -> bytes:
"""The protocol's read_* methods return the response data with its 11-byte prefix."""
return bytes(data)[CONTENT:]
def main() -> int:
ap = argparse.ArgumentParser(description=__doc__.splitlines()[0])
ap.add_argument("port", nargs="?", help="serial port, e.g. /dev/ttyACM0")
ap.add_argument("action", choices=ACTIONS)
ap.add_argument("--host")
ap.add_argument("--tcp-port", type=int, default=9034)
ap.add_argument("--baud", type=int, default=115200)
a = ap.parse_args()
if not (a.port or a.host):
ap.error("give a serial port or --host")
transport = TcpTransport(a.host, port=a.tcp_port) if a.host else SerialTransport(a.port, a.baud)
mm = MicromateClient(transport) # no execute(): nothing here can transmit a write
mm.open()
try:
info = mm.connect()
p = mm.protocol
reads = {}
if a.action == "start":
plan = plan_start_monitoring()
elif a.action == "stop":
plan = plan_stop_monitoring()
elif a.action.startswith("call-home"):
ch = _content(p.read_call_home_config())
reads["0x2C"] = {"len": len(ch)}
plan = plan_call_home_enabled(ch, a.action == "call-home-on")
else:
name = mm.get_active_setup()
prefs = _content(p.read_event_index())
trig = _content(p.read_trigger_config())
setup = _content(p.read_compliance_config())
reads = {"active_setup": name,
"0x08": {"len": len(prefs), "hex": prefs.hex()},
"0x2E": {"len": len(trig), "hex": trig.hex()},
"0x1A": {"len": len(setup), "hex": setup.hex()}}
plan = plan_setup_push(prefs, trig, setup, name)
out = plan.describe()
out["unit"] = {"serial": info.serial, "firmware_line": info.firmware_line}
out["reads"] = reads
print(json.dumps(out, indent=1))
finally:
mm.close()
return 0
if __name__ == "__main__":
sys.exit(main())
+338
View File
@@ -0,0 +1,338 @@
#!/usr/bin/env python3
"""
mm_link.py — a "perfect modem" between THOR and a Micromate, with a readable
log and deliberate fault injection.
Why
---
THOR gives almost no visibility into a connection: a refresh button, two poll
intervals, and no way to see whether a check succeeded, timed out, or was never
sent. When a unit "won't stay connected" there is nothing to look at.
This sits where the cellular modem would sit and answers the question directly:
* **What is THOR actually doing?** Every frame is decoded and timestamped —
`POLL`, `MONITOR_STATUS`, `SETUP_NAME_READ` — not a hex dump.
* **Is it even trying?** Silence is visible: the log shows gaps.
* **How does it behave when the link misbehaves?** Faults can be injected on
demand, which a real cell link will not do on cue.
Point THOR at this host and port exactly as if it were a modem (Communication:
TCP, IP: <this host>, Port: <--listen>).
Fault injection
---------------
Write a mode into the control file (default `mm_link.ctl`) and it takes effect
on the next byte:
echo pass > mm_link.ctl # normal relay
echo blackhole > mm_link.ctl # TCP stays up, bytes are swallowed
echo drop > mm_link.ctl # close the connection abruptly (RST-ish)
echo delay:2.0 > mm_link.ctl # forward, but 2 s late in both directions
echo onewaydev > mm_link.ctl # THOR->unit passes, unit->THOR is swallowed
**`blackhole` is the one that matters.** It reproduces the classic cellular
failure: the socket is still open as far as both ends are concerned, but nothing
crosses. A client that relies on TCP to tell it the peer is gone will sit there
until the OS keepalive fires — which by default is about two hours.
Usage
-----
python3 bridges/mm_link.py --serial /dev/ttyACM0 --baud 115200 \\
--listen 12345 --logdir ~/mm-captures
Writes, per session:
<logdir>/mmlink_<ts>/session.log decoded, timestamped, human-readable
<logdir>/mmlink_<ts>/raw_bw.bin THOR -> unit, raw
<logdir>/mmlink_<ts>/raw_s3.bin unit -> THOR, raw
The raw pair loads straight into `scratch/mm_frame_parse.py`.
"""
from __future__ import annotations
import argparse
import datetime
import os
import socket
import sys
import threading
import time
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent / "scratch"))
try:
from mm_frame_parse import SUBNAME, destuff # noqa: F401
except Exception: # pragma: no cover
SUBNAME = {}
import errno
import select
import termios
DLE, STX, ETX, ACK = 0x10, 0x02, 0x03, 0x41
_BAUD = {9600: termios.B9600, 19200: termios.B19200, 38400: termios.B38400,
57600: termios.B57600, 115200: termios.B115200}
class SerialPort:
"""Minimal raw serial port on stdlib termios — no pyserial dependency.
The bench hosts are whatever is to hand; requiring a pip install on someone
else's machine is a poor trade for the ~30 lines this saves.
"""
def __init__(self, path: str, baud: int):
if baud not in _BAUD:
raise ValueError(f"unsupported baud {baud}; pick one of {sorted(_BAUD)}")
self.fd = os.open(path, os.O_RDWR | os.O_NOCTTY | os.O_NONBLOCK)
a = termios.tcgetattr(self.fd)
a[0] = 0 # iflag: no translation
a[1] = 0 # oflag: raw
a[2] = termios.CS8 | termios.CREAD | termios.CLOCAL # cflag: 8N1, ignore modem lines
a[3] = 0 # lflag: non-canonical, no echo
a[4] = a[5] = _BAUD[baud]
a[6] = list(a[6])
a[6][termios.VMIN] = 0
a[6][termios.VTIME] = 0
termios.tcsetattr(self.fd, termios.TCSANOW, a)
termios.tcflush(self.fd, termios.TCIOFLUSH)
def read(self, n: int) -> bytes:
r, _, _ = select.select([self.fd], [], [], 0.2)
if not r:
return b""
try:
return os.read(self.fd, n)
except OSError as e:
if e.errno in (errno.EAGAIN, errno.EWOULDBLOCK):
return b""
raise
def write(self, data: bytes) -> None:
while data:
try:
data = data[os.write(self.fd, data):]
except OSError as e:
if e.errno in (errno.EAGAIN, errno.EWOULDBLOCK):
select.select([], [self.fd], [], 0.2)
continue
raise
def close(self) -> None:
try:
os.close(self.fd)
except OSError:
pass
def name_of(sub: int, is_request: bool) -> str:
if is_request:
return SUBNAME.get(sub, f"SUB_{sub:02X}")
return "rsp " + SUBNAME.get(0xFF - sub, f"SUB_{0xFF - sub:02X}")
class FrameSniffer:
"""Accumulate bytes and report complete frames, without altering the stream."""
def __init__(self, is_request: bool):
self.is_request = is_request
self.buf = bytearray()
def feed(self, data: bytes):
"""Yield (sub, payload_len) for each complete frame seen."""
self.buf.extend(data)
while True:
start = -1
for i, b in enumerate(self.buf):
if self.is_request and b == ACK and i + 1 < len(self.buf) and self.buf[i + 1] == STX:
start = i
break
if not self.is_request and b == STX:
start = i
break
if start < 0:
if len(self.buf) > 8192:
del self.buf[:-16]
return
j = start + (2 if self.is_request else 1)
end = -1
while j < len(self.buf):
if self.buf[j] == DLE and j + 1 < len(self.buf):
j += 2
continue
if self.buf[j] == ETX:
end = j
break
j += 1
if end < 0:
return # wait for more bytes
body = self.buf[start:end + 1]
del self.buf[:end + 1]
# SUB sits at a fixed spot past the leading framing -- but it is
# DLE-escaped when its own value is 0x02/0x03/0x04/0x10, so a raw
# read reports 0x10 for those. SUB 0x02 was being logged as
# "SUB_10" until this was handled.
off = 5 if self.is_request else 3
if len(body) > off:
sub = body[off]
if sub == DLE and len(body) > off + 1:
sub = body[off + 1]
yield sub, len(body)
class Link:
def __init__(self, args):
self.args = args
self.mode = "pass"
self.delay = 0.0
self.ctl = Path(args.control)
self.session: Path | None = None
self.log_fh = None
self.raw = {}
self.t0 = time.time()
self.counts = {}
# ── logging ────────────────────────────────────────────────────────────
def open_session(self):
ts = datetime.datetime.now().strftime("%Y%m%d_%H%M%S")
self.session = Path(self.args.logdir) / f"mmlink_{ts}"
self.session.mkdir(parents=True, exist_ok=True)
self.log_fh = open(self.session / "session.log", "a", buffering=1)
self.raw = {
"bw": open(self.session / "raw_bw.bin", "ab"),
"s3": open(self.session / "raw_s3.bin", "ab"),
}
self.say(f"=== session {ts} — serial {self.args.serial} @ {self.args.baud} ===")
def say(self, text: str):
line = f"{datetime.datetime.now().strftime('%H:%M:%S.%f')[:-3]} {text}"
print(line, flush=True)
if self.log_fh:
self.log_fh.write(line + "\n")
# ── control file ───────────────────────────────────────────────────────
def poll_control(self):
while True:
try:
if self.ctl.exists():
want = self.ctl.read_text().strip().lower()
if want.startswith("delay:"):
d = float(want.split(":", 1)[1])
if ("delay", d) != (self.mode, self.delay):
self.mode, self.delay = "delay", d
self.say(f"*** MODE -> delay {d}s ***")
elif want and want != self.mode:
self.mode, self.delay = want, 0.0
self.say(f"*** MODE -> {want} ***")
except Exception:
pass
time.sleep(0.25)
# ── the relay ──────────────────────────────────────────────────────────
def pump(self, src, dst, tag: str, is_request: bool, stop: threading.Event):
sniff = FrameSniffer(is_request)
arrow = "THOR->unit" if is_request else "unit->THOR"
last = time.time()
while not stop.is_set():
timed_out = False
try:
data = src.recv(4096) if isinstance(src, socket.socket) else src.read(4096)
except TimeoutError:
timed_out = True
# socket.timeout subclasses OSError, so it MUST be caught first.
# Treating it as a dead socket closes the connection after 200 ms
# of quiet -- which is exactly what `blackhole` produces, so the
# relay killed the link it was supposed to be faking a fault on.
data = b""
except OSError:
break
if isinstance(src, socket.socket) and data == b"" and not timed_out:
self.say(f"{arrow}: peer closed the connection")
break
if not data:
if time.time() - last > self.args.quiet_after and self.counts:
self.say(f"--- {self.args.quiet_after:.0f}s with no traffic ---")
last = time.time()
continue
last = time.time()
self.raw[tag].write(data)
self.raw[tag].flush()
for sub, ln in sniff.feed(data):
label = name_of(sub, is_request)
self.counts[label] = self.counts.get(label, 0) + 1
self.say(f"{arrow} {label:<20} ({ln} B)"
+ ("" if self.mode == "pass" else f" [mode={self.mode}]"))
mode = self.mode
if mode == "drop":
self.say(f"{arrow}: DROPPING the connection (fault injection)")
stop.set()
break
if mode == "blackhole":
continue # swallow, keep the socket open
if mode == "onewaydev" and not is_request:
continue # unit's replies never reach THOR
if mode == "delay" and self.delay:
time.sleep(self.delay)
try:
if isinstance(dst, socket.socket):
dst.sendall(data)
else:
dst.write(data)
except OSError:
break
stop.set()
def serve(self):
srv = socket.socket(socket.AF_INET, socket.SOCK_STREAM)
srv.setsockopt(socket.SOL_SOCKET, socket.SO_REUSEADDR, 1)
srv.bind(("0.0.0.0", self.args.listen))
srv.listen(5)
self.open_session()
self.say(f"listening on 0.0.0.0:{self.args.listen} control file: {self.ctl}")
self.say("point THOR at this host/port as Communication=TCP")
threading.Thread(target=self.poll_control, daemon=True).start()
while True:
conn, addr = srv.accept()
conn.settimeout(0.2)
self.say(f"+++ THOR connected from {addr[0]}:{addr[1]} +++")
try:
ser = SerialPort(self.args.serial, self.args.baud)
except OSError as e:
self.say(f"!!! cannot open {self.args.serial}: {e}")
conn.close()
continue
stop = threading.Event()
ts = [
threading.Thread(target=self.pump, args=(conn, ser, "bw", True, stop), daemon=True),
threading.Thread(target=self.pump, args=(ser, conn, "s3", False, stop), daemon=True),
]
for t in ts:
t.start()
for t in ts:
t.join()
conn.close()
ser.close()
summary = ", ".join(f"{k}x{v}" for k, v in sorted(self.counts.items()))
self.say(f"--- connection closed. frames this session: {summary or 'none'} ---")
def main():
ap = argparse.ArgumentParser(description=__doc__,
formatter_class=argparse.RawDescriptionHelpFormatter)
ap.add_argument("--serial", default="/dev/ttyACM0")
ap.add_argument("--baud", type=int, default=115200)
ap.add_argument("--listen", type=int, default=12345)
ap.add_argument("--logdir", default=os.path.expanduser("~/mm-captures"))
ap.add_argument("--control", default="mm_link.ctl")
ap.add_argument("--quiet-after", type=float, default=30.0,
help="log a marker after this many seconds of silence")
Link(ap.parse_args()).serve()
if __name__ == "__main__":
main()
+239
View File
@@ -0,0 +1,239 @@
#!/usr/bin/env python3
"""
mm_probe.py — answer "why can't we reach this unit?" in one command.
THOR reports a failed connection as "disconnected" and nothing else. That single
word covers at least four completely different faults with four different fixes,
and telling them apart is the difference between a modem reboot and a site visit:
* **connection refused** something answered and said no — wrong port, or the
modem is refusing a further session
* **connect timed out** nothing answered at all — trusted-IP whitelist,
firewall, or the modem is off the network
* **connected, no reply** the MODEM answered but the unit did not. The TCP
path is fine; the modem is not forwarding to serial.
This is the signature of a wedged transparent-TCP
session, and it is the one THOR cannot distinguish
from any of the others
* **replied** the unit is alive; the problem is upstream software
Read-only. It sends `POLL`, then optionally `SERIAL` and the state read — the
same three commands THOR's own connection check uses — and never writes.
Usage
-----
python3 bridges/mm_probe.py 63.45.161.30:9034
python3 bridges/mm_probe.py 10.0.0.8:12345 --timeout 5
python3 bridges/mm_probe.py <host:port> --slots 3
`--slots N` opens N connections at once and reports how many the far end accepts.
A transparent-TCP modem typically serves **one** session; if the first succeeds
and the rest are refused or hang, that confirms the single-slot behaviour and
explains why a leaked session takes a unit offline until the slot frees.
Works for both series: a Series III reply opens `DLE STX`, a Micromate reply
opens with a bare `STX`, so the probe also tells you which one answered.
"""
from __future__ import annotations
import argparse
import socket
import sys
import time
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
from minimateplus.framing import build_bw_frame # noqa: E402
DLE, STX, ETX = 0x10, 0x02, 0x03
def destuff(raw: bytes) -> bytes:
"""Strip framing and DLE escapes; return the payload without its checksum."""
i = 1 if raw and raw[0] == STX else (2 if len(raw) > 1 and raw[1] == STX else 0)
out = bytearray()
while i < len(raw):
b = raw[i]
if b == DLE and i + 1 < len(raw):
out.append(raw[i + 1])
i += 2
continue
if b == ETX:
break
out.append(b)
i += 1
return bytes(out[:-1]) if len(out) > 1 else b""
# Reads are two-step on Series III: a probe at offset 0, then a data read at the
# block's length. THOR sends these offsets, and they also work on a Micromate.
OFFSETS = {0x5B: 0x0030, 0x15: 0x000A, 0x49: 0xFFFF}
def exchange(sock: socket.socket, sub: int, timeout: float) -> tuple[bytes, float]:
sock.sendall(build_bw_frame(sub, OFFSETS.get(sub, 0)))
t0 = time.time()
buf, deadline = b"", t0 + timeout
sock.settimeout(0.3)
while time.time() < deadline:
try:
chunk = sock.recv(4096)
if not chunk:
break
buf += chunk
if buf.endswith(bytes([ETX])) and len(buf) > 8:
break
except TimeoutError:
continue
except OSError:
break
return buf, time.time() - t0
def step(n: int, label: str, result: str) -> None:
print(f" [{n}] {label:.<28} {result}")
def probe(host: str, port: int, timeout: float) -> int:
print(f"\ntarget {host}:{port} (read-only: POLL, SERIAL, state)\n")
# ── 1. TCP ────────────────────────────────────────────────────────────
t0 = time.time()
try:
sock = socket.create_connection((host, port), timeout=timeout)
except ConnectionRefusedError:
step(1, "TCP connect", f"REFUSED after {1000*(time.time()-t0):.0f} ms")
print("\nverdict: something answered and actively refused.")
print(" Not a silent firewall drop — the host is reachable.")
print(" Wrong port, the service is down, or the modem is refusing")
print(" an additional session because its one slot is in use.")
return 2
except (TimeoutError, socket.timeout):
step(1, "TCP connect", f"TIMED OUT after {time.time()-t0:.1f} s")
print("\nverdict: nothing answered at all.")
print(" A silent drop, which is what a trusted-IP whitelist looks")
print(" like — it discards rather than refuses. Check the modem's")
print(" Trusted IPs (and note a VPN changes the IP you arrive from),")
print(" the firewall, and whether the modem is on the network.")
return 3
except OSError as e:
step(1, "TCP connect", f"FAILED: {e}")
return 4
step(1, "TCP connect", f"ok ({1000*(time.time()-t0):.0f} ms)")
# ── 2. POLL ───────────────────────────────────────────────────────────
try:
raw, dt = exchange(sock, 0x5B, timeout)
except OSError as e:
step(2, "POLL", f"send failed: {e}")
sock.close()
return 4
if not raw:
step(2, "POLL", f"NO REPLY in {timeout:.1f} s")
print("\nverdict: the MODEM answered but the unit did not.")
print(" TCP is fine end to end — something accepted the connection.")
print(" What is missing is the serial side. Two quite different")
print(" causes produce this, and they are NOT distinguishable from")
print(" here:")
print("\n 1. SOMEONE ELSE HOLDS THE SESSION. These modems bridge ONE")
print(" TCP session to serial at a time. A second connection is")
print(" accepted and then simply not forwarded. Confirmed 2026-09-26:")
print(" with THOR connected this probe saw exactly this; the moment")
print(" THOR disconnected the same probe returned the serial number.")
print(" ** Check whether THOR (or anything else) has the unit first. **")
print("\n 2. The serial path is genuinely broken — a stale session the")
print(" modem never released, a cable the unit cannot enumerate, or")
print(" a unit that is off.")
print("\n Try, in order:")
print(" 1. Disconnect any other client and re-probe. If it answers,")
print(" it was contention, not a fault.")
print(" 2. The cable's chipset. A Micromate drives FTDI and CDC-ACM")
print(" only — a Prolific PL2303 gives it no serial port at all.")
print(" lsusb: FTDI is 0403, Prolific 067b.")
print(" 3. Power-cycle the UNIT with the cable attached (hold power")
print(" 5 s, through the two-stage prompt). Its USB host rescans")
print(" on cold boot; it may not on hot-swap.")
print(" 4. AirLink OS -> TCP Idle Timeout. If 0/disabled, a stale")
print(" session holds the slot indefinitely. 2 minutes is the")
print(" value this project standardised on.")
sock.close()
return 5
series = "Series III (DLE STX)" if raw[0] == DLE else "Micromate (bare STX)"
step(2, "POLL", f"reply {len(raw)} B in {1000*dt:.0f} ms")
p = destuff(raw)
ok = len(p) > 3 and p[2] == 0xFF - 0x5B
step(3, "frame", f"{'valid' if ok else 'MALFORMED'}, {series}")
if not ok:
print("\nverdict: something replied, but not a seismograph.")
print(" Another service is on this port, or the modem is in a mode")
print(" that injects its own text (check Quiet Mode / AT echo).")
print(f" first bytes: {raw[:16].hex(' ')}")
sock.close()
return 6
# ── 3. identity + state ───────────────────────────────────────────────
for n, (sub, label) in enumerate(((0x15, "serial"), (0x49, "state")), start=4):
try:
r, dt = exchange(sock, sub, timeout)
d = destuff(r)[5:]
if sub == 0x15:
# serial is a null-terminated run; a further field follows it
serial = bytes(d[11:]).split(b"\x00")[0]
step(n, label, serial.decode("ascii", "replace") or "(empty)")
else:
step(n, label, "MONITORING" if len(d) > 11 and d[11] else "idle")
except OSError:
step(n, label, "no reply")
sock.close()
print("\nverdict: the unit is alive and answering.")
print(" If THOR still shows it disconnected, the fault is in THOR, not")
print(" the network or the device.")
return 0
def slots(host: str, port: int, n: int, timeout: float) -> None:
print(f"\nopening {n} simultaneous connections to {host}:{port}\n")
held = []
for i in range(n):
try:
s = socket.create_connection((host, port), timeout=timeout)
held.append(s)
step(i + 1, f"connection {i+1}", "accepted")
except ConnectionRefusedError:
step(i + 1, f"connection {i+1}", "REFUSED")
except (TimeoutError, socket.timeout):
step(i + 1, f"connection {i+1}", "timed out")
except OSError as e:
step(i + 1, f"connection {i+1}", f"failed: {e}")
print(f"\n{len(held)} of {n} accepted.")
if len(held) == 1:
print(" Single-slot behaviour confirmed — this far end serves ONE")
print(" session at a time. A connection that is never closed takes")
print(" the unit offline until the idle timeout frees the slot.")
for s in held:
s.close()
def main() -> int:
ap = argparse.ArgumentParser(description=__doc__,
formatter_class=argparse.RawDescriptionHelpFormatter)
ap.add_argument("target", help="host:port, e.g. 63.45.161.30:9034")
ap.add_argument("--timeout", type=float, default=10.0)
ap.add_argument("--slots", type=int, metavar="N",
help="open N simultaneous connections to test single-slot behaviour")
a = ap.parse_args()
host, _, port = a.target.rpartition(":")
if not host:
ap.error("target must be host:port")
if a.slots:
slots(host, int(port), a.slots, a.timeout)
return 0
return probe(host, int(port), a.timeout)
if __name__ == "__main__":
raise SystemExit(main())
+223 -1
View File
@@ -6,7 +6,15 @@ Series IV event-file format. Sibling to
Series III "Rosetta Stone") — this doc holds what we know so far and
the open questions still to crack.
**Status (2026-05-28):** ASCII text sidecar fully decoded (1,014
> ⚠ **The "Status (2026-05-28)" block below is SUPERSEDED.** Its geo LSB
> (0.0003), its IDFH scale (`/32768 × 10`), its fixed body offset (`0x0f1f`)
> and its "87–99% byte-exact / loud events truncate" caveat were all wrong or
> incomplete. See **[Verified against Thor's own exports
> (2026-09-10)](#verified-against-thors-own-exports-2026-09-10)** — the
> decoder is now per-sample exact on 1,057,536/1,057,536 samples. The block
> is kept only for the reverse-engineering trail.
**Status (2026-05-28, SUPERSEDED):** ASCII text sidecar fully decoded (1,014
sample files round-trip). **Thor IDFW** binary now decodes via
`micromate.idf_file.read_idf_file()` — reuses the BW segment-rotated
block codec verbatim at fixed body offset `0x0f1f`; metadata (serial,
@@ -44,6 +52,220 @@ signature and raises `NotImplementedError` pointing callers at
time-of-peak); the two uint16 fields (probably PVS contributions);
8-byte interval tail (PVS data); mic dB(L) exact conversion constant.
## Verified against Thor's own exports (2026-09-10)
**The series-4 decoder is now per-sample exact.** 1,057,536 / 1,057,536
geophone samples across all 153 genuine Thor waveform files reproduce Thor's
own CSV export exactly; histogram peaks land within 2% on 858/858 files
(median error −0.004%).
### Ground truth — it was there all along
Thor writes `TXT/`, `CSV/`, `XML/` and `PDF/` exports beside every binary:
```
<serial dir>/UM13981_20220207084555.IDFW
<serial dir>/CSV/UM13981_20220207084555.IDFW.csv
```
The **CSV carries a per-sample block** — four columns (Tran, Vert, Long, Mic)
in in/s and psi, after the 2-column report header. That is the series-4
equivalent of Blastware's `_ASCII.TXT` exports, and it gives 1,012 paired
files (152 IDFW + 860 IDFH). Earlier notes in this file and in
`micromate/idf_file.py` asserted "Thor has no ASCII ground truth in the
corpus"; that was wrong, and it is why the decoder sat pinned to a
superseded walker with a scaling constant nobody could check.
Harness: `scratch/verify_thor_against_csv.py`.
### Geo LSB = 0.000310308 in/s per count (NOT 0.0003)
The old 0.0003 was read off the smallest non-zero sample in the exports —
but that is Thor's **4-decimal display rounding of the LSB, not the LSB**.
It read every series-4 geophone sample **3.3% low**. The quantisation
ladder gives it away: counts 1..6 export as 0.0003, 0.0006, 0.0009, 0.0012,
0.0016, 0.0019 — an LSB of exactly 0.0003 would end 0.0015, 0.0018.
Each exported sample constrains the LSB to the window that rounds to its
printed value. Intersecting 991,415 such constraints gives
```
LSB ∈ [0.000310307933, 0.000310308057] width 1.2e-10
```
so `_GEO_LSB_IPS = 0.000310308`, i.e. full scale 10.0 in/s = **32226.05
counts**. Corroboration: an IDFH interval that never recorded keeps its
min/max accumulator at its ±full-scale seed, and that seed is
`(min=+32226, max=-32226)`. ⚠ The tempting closed form `10.0/32226` is
very slightly wrong — it lands 4.5e-10 above the feasible window and loses
78 boundary samples while never winning one. **Series III uses 32000 counts
for the same 10.0 in/s, so the two generations do not share a scale.**
Independently confirmed on 8 production units (UM6047, UM11402, UM11719,
UM12947, UM13981, UM14133, UM20146, UM20147): every unit's median PPV error
against its device-reported peak moved from −3.3% to within ±0.03%. It is a
global constant, not a per-unit calibration.
### IDFH segment header: the counter is a uint16, and it is cumulative
```
[length_be 2B][0a 00 00 00][counter_be 2B][05 3f]
```
`counter` is the **0-based cumulative index of the last interval in the
segment** — 9, 19, 29, ... for the usual 10-intervals-per-segment layout
(`length` = 730).
The validator used to require `counter`'s high byte to be `0x00`. That
silently **capped every histogram at 250 intervals**: once the cumulative
counter passed 255 the high byte went non-zero and every later segment was
rejected. Any run longer than ~4 hours lost its tail — frequently the part
holding the event peak, so the file's PPV read low. **540 of 858 corpus
files were affected**; fixing it moved histogram peaks from 48.3% to 93.8%
within 0.5% of Thor's reported PPV.
### Unwritten interval slots carry a ±full-scale seed
An interval the device reserved but never wrote keeps `min = +32226`,
`max = -32226` on all four channels — `min > max`, impossible for real data.
Decoded naively it yields a 10.0 in/s peak on every channel and, being a
max-over-intervals, poisons the whole file's PPV. Rare but real: exactly 1
of 497,611 corpus intervals, and it inflated that file's Long PPV from
0.0081 to 10.0 in/s. The inversion is all-or-nothing across channels (0
partial cases), so requiring every channel to be inverted is a safe test.
### Record mode `00 00` — raw int16 absolute (MODE_RAW16)
The record chain's mode field at `off+8` takes a fourth value:
| mode | meaning | header |
|---|---|---|
| `02 00` | deltas + two int16 anchors | 14 B |
| `01 00` | absolute, tagged blocks | 10 B |
| `00 03` | raw 12-bit absolute, untagged | 10 B |
| **`00 00`** | **raw int16 BE absolute, untagged** | **10 B** |
A `MODE_RAW16` record with `length = 1032` carries exactly
`(1032 - 8) / 2 = 512` samples and reproduced Thor's export **512/512
exactly** on first test. Thor uses it for segment 0 (the pre-trigger
window) on some events. Before this mode existed the record fell through
the dispatch unhandled, so the channel silently lost its first 512 samples —
which is what produced the "loud events truncate" symptom.
`MODE_ABSOLUTE` is also valid as a **preamble** (the implicit segment-0 Tran
record); its tagged blocks start at `body[3]`, not `body[7]`, because its
header is 10 bytes rather than 14.
### Body offset is not fixed at 0x0f1f — and 0x0f1f is really a record + 7
A "body offset" is `<record start> + 7`, so that `body[0]` is the segment
index and `body[1:3]` is the mode. The canonical `0x0f1f` is simply the
record at `0x0f18`.
Searching for the literal preamble `00 02 00` finds only MODE_DELTA bodies,
and worse, it **matches the `[seg][mode]` bytes inside any record header**,
so the scan could pick a candidate part-way down the chain. That decodes a
plausible-looking but rotation-shifted body which drops each channel's
segment 0 — the real cause of the remaining truncations.
`_find_waveform_body_offset()` now anchors on record headers (the
`<channel_id> 00 00` signature at `+4`, validated with `is_record()`),
takes the **chain head** — a record no other record's length field points at
— and trial-decodes `head + 7`, preferring the candidate where all four
channels come out the same length.
⚠ Do **not** scan for candidate preambles instead: `MODE_RAW16` is
`00 00`, so every run of three zero bytes looks like a body start and each
costs a full trial decode (~0.5 s/file measured, vs 6 ms/file now).
### `40 NN` is not capped at NN=8 (2026-09-11)
`data_block_len()` rejected any `40 NN` int16 block with `NN > 0x08`. The cap
had no evidence behind it — every corpus available when it was written used
only NN ∈ {1, 2, 3, 4, 8}, so it was never exercised. Loud events use much
wider blocks:
| corpus | `40 NN` values | walker stops |
|---|---|---|
| first + 3-channel corpora | 1, 2, 3, 4, 8 | none |
| UM12947 2025-07..09 | 2, 4, 8, **12, 16, 20 … 196** | every value > 8 |
Because `walk_body`/`run` stop at the first unrecognised tag rather than
raising, this surfaced as **silently short channels** — e.g. Tran 1812 /
Vert 2132 / Long 2324 on a file whose export has 2324 for all three. The
real bound is the buffer (and the caller's record end), not a magic constant.
Verified against Thor's exports for UM12947 (2025-07-14 … 2025-09-25, 167
waveforms): length mismatches **22 → 0**, and **1,476,242 / 1,476,249**
samples exact.
⚠ These events are **not** truncated recordings, which was the competing
hypothesis — the exports carry the full sample count.
**The 7 residual samples are Thor's rounding, not ours.** Each differs by
exactly one 4th-decimal tick (e.g. decoded 3.3551 vs export 3.3550).
Intersecting the per-sample rounding constraints over this corpus is
**infeasible** — the binding pair (count 2013 → 0.6247, count 4351 → 1.3501)
contradict by 2.3e-11, i.e. 7e-5 relative. No single linear LSB can
reproduce every printed value, so Thor is not doing plain round-half-up on
`count × LSB`. Do not retune `_GEO_LSB_IPS` to chase these; it is already
pinned to ~1e-11.
### Mic-disabled units are a distinct shape (2026-09-10, second corpus)
Some units run with the microphone disabled — **3 channels, not 4** — and that
changes two structural things. Confirmed on the `9-10-26-csv-req` corpus
(UM11402, UM12947, UM20147): 139/139 waveforms and 877/877 histograms.
**Waveform: the body starts earlier.** A 3-channel unit has a shorter fixed
header and puts its record chain head at **`0x0dba`**, below the old
`_BODY_SCAN_FLOOR` of `0x0E00`. The head was therefore invisible to the scan,
which fell through to the *Vert* segment-0 record and decoded a body shifted
one position around the channel rotation. The signature is unmistakable:
```
Tran 3072 / Vert 2560 / Long 3072 / MicL 0 <- Vert exactly 512 short
```
46 of 139 files in that corpus were affected; all 46 became per-sample exact
once the floor dropped to `0x0C00`. Note the body-offset scoring also had to
stop requiring four channels — `len(lengths) >= 3`, not `== 4`, or `equal` is
permanently False for these events and the pick falls back to raw sample count.
**Histogram: the interval record is 56 bytes, not 72.**
```
interval_size = 16 × n_channels + 8 (72 for 4 channels, 56 for 3)
```
It is **not a constant**, and it cannot be inferred from `length` alone.
Derive the interval count from the segment counter — it is cumulative, so
`n = counter - previous_counter` — and then `stride = (length - 10) / n`.
`n_channels` follows from `(stride - 8) / 16`.
Assuming 72 read 7 intervals out of each 10-interval segment and then walked
off alignment into garbage that decoded as ~10 in/s peaks — inflating those
files' PPV by up to 191,000%. Fixing it moved the second corpus from 56.6% to
**100.0%** of histograms within 2% of Thor's reported PPV, and recovered 4
files that previously decoded no intervals at all.
### What is still open
- ~~23 of 575 production IDFW files~~ — **RESOLVED 2026-09-11.** Production
IDFW is now **575/575** with zero truncations and zero decode failures
(median PPV error −0.0007%). See "`40 NN` is not capped at NN=8" above.
- Mic → psi scale is still the rough `2.14e-6` regression, not derived.
- Per-channel `int16 field4` in the IDFH interval record (possibly
time-of-peak) and the 8-byte tail (PVS data) remain undecoded.
⚠ **Thor's histogram PPV has a display floor of 0.0050 in/s.** In the
production store 6,080 sidecar PPV values are exactly 0.0050 (next most
common value: 275 occurrences), and **41.4% of IDFH sidecars report a
component PPV larger than their own vector sum** — geometrically impossible.
On those quiet files the decoder's ~0.0025 in/s is *more* accurate than the
reference; do not "fix" the decoder to match it.
### Codec breakthroughs (2026-05-28)
- **Body offset is a fixed `0x0f1f`** across 151/154 corpus IDFW
+17
View File
@@ -11,6 +11,13 @@
| Date | Section | Change |
|---|---|---|
| 2026-10-27 | §3 writes | **⚠ RETRACTS the write-frame model (#46, measured).** Every Blastware request on record re-encodes under the uniform rule (02/03/04/10 escaped, SUM8): 3,869/3,869 frames in the Feb–Apr 2026 captures, plus BE9441's 26 write frames of 2026-10-26. A write's [4:6] is its data LENGTH. Config blocks are their header N + 2 bytes: event index (68) and trigger (82) are written as read plus `02 00` / `00 00` (constant on 15 sends); waveform data (69) and the 2,092-byte compliance image (71) are written whole, the latter in addressed chunks (params[2:4] = address; 1,024 B in March, 512 B with Blastware 10.74). The trailing two bytes are not a CRC and went out stale, so the unit evidently ignores them. "Only BW_CMD doubled", the "DLE-aware checksum", "offset = data[1] + 2" and "chunks 1,027 / 1,055 at offset 0x1004" were these frames read with their escape bytes in. The trigger block is read first (SUB 0x2E, 26 bytes); its byte 5 has been 01 / 03 / 04 by unit and session (meaning unknown). |
| 2026-10-26 (4) | §3, §10 | **Replies follow the request rule; a write-frame suspicion (inferred).** Measured on all 748 reply frames of the 10-26 recording: the unit escapes exactly 02/03/04/10 with a `10`, and the checksum is **SUM8 of the unescaped payload**, 748/748. The long-held "S3 response checksums frequently fail SUM8" (`protocol._validate_frame`) is `S3FrameParser`'s own doing: it keeps the `10` of `10 02/03/04` in its output (consumers rely on that) and sums it, so 502/540 A5 replies read invalid. 🔶 **Inferred only:** `build_bw_write_frame`'s model ("raw except BW_CMD", "DLE-aware checksum") shows the same fingerprints as the retracted 5A model -- SUB 71's "offset 0x1004" reads as length 0x0400 escaped, and Blastware escapes `03` in write data (§3 note, 2026-04-20). A write whose payload holds a bare 02/03/04/10 may be malformed; one Blastware config-write capture settles it. Not acted on. |
| 2026-10-26 (3) | §3, §7.8, §10 | **⚠ RETRACTS the 5A "non-standard frame" model; the 64 KB page bug is FIXED (measured).** A bridge recorded Blastware downloading all 8 of BE9441's events, 4 crossing a 64 KB page (`tests/fixtures/minimate-bench-10-26-26-blastware/`). **Every request** is the standard 16-byte payload with a SUM8 checksum and **every 02, 03, 04 and 10 DLE-escaped**, payload and checksum alike: 748/748 re-encode byte-identically. §10's "only 0x10 is stuffed" is half the rule. **A 5A request is an ordinary request** `[10 00 5A 00][length BE 2][address BE 4][zeros 6]`, where length is 0x0200 per chunk and the remainder for TERM. The walk: the event's start address, +0x200 at a time as plain 32-bit addresses (carrying into the page byte), then TERM at the next boundary for exactly the remainder, ending at STRT's full 32-bit end key. **Misreadings retracted:** the fixed "offset 0x1002" is length 0x0200 escaped (`10 02 00`); the "metadata pages at 0x1002 / 0x1004, global, read once per session" are the first event's own chunks at 0x0200 and 0x0400; the "11-byte params" counted the length's low byte; the "partial DLE stuffing" carve-outs were the escape rule seen half; the 16-bit counter is why a walk could not leave its page. **Verified live on BE9441:** all 8 events downloaded whole, the 4 crossings included, each matching the unit's own 0C peaks. Code `887e75d`. |
| 2026-10-26 (2) | §7.8 | **The 64 KB page bug, narrowed (measured, BE9441).** Blastware's own downloads of all 20 events (Brian, `example-events/10-25-26 - thumps`) give byte-exact ground truth. SFM's downloads of events 0, 1, 3, 4 and 10 are **byte-identical** to Blastware's. Importing Blastware's files first (the watcher route) makes SFM's downloads of the same events return `already_stored`: the unit's 0C and Blastware's file agree on (serial, timestamp). For an event that crosses a page (event 2, `0111c92c` → STRT end key `01122f06`, full 32 bits) a read-only test walk with the page byte carried (params `00 01 12 01 2c`) got a proper A5 reply for the first chunk in page 0x12, echoing `01 12 01 2c`. The second chunk, `00 01 12 03 2c`, got no reply frame: a raw 0x03 (ETX) inside the params. Page 0x11 never shows this, because event 1 skips 0x0000–0x05FF, so no counter there has a 02/03/04 byte. Every later page does. ⚠ How Blastware encodes a lone 02/03/04 inside params is unknown: §7.8 says `10 02/03/04` is kept as a literal pair, which would shift the address. A wire capture of Blastware downloading BE9441 event 2 or 19 settles it. Blastware's files are fixtures (`tests/fixtures/minimate-bench-10-25-26/blastware/`). |
| 2026-10-26 | §7.8 | **5A requests must DLE-escape a checksum that is a framing byte (measured, BE9441).** The request for chunk 0x7D06 of event 01122f06 ends `… 02 03`: a bare 0x02 checksum (STX) before ETX. BE9441 never answered it, twice on two days, and rebooted ~11 s later each time; that was the 'mid-download reboot' of 2026-10-25 (row below). Sent as `… 10 02 03` it answered in 28 ms. So did chunk 0x7F06 (checksum 0x04 → `10 04`) and 0x8B06 (checksum 0x10 → `10 10`; sent bare, that reads as DLE+ETX), and the event downloaded whole and matched the unit's peaks. Escape set {02, 03, 04, 10}: a Micromate's for every byte (251/251 THOR requests), and consistent with §7.8's de-stuffing rule (`10 02/03/04` literal). About 1 chunk request in 64 has such a checksum. ⚠ Not known: whether standard (non-5A) requests need the same. No such keyed-read checksum has been sent. Also measured on the re-run: events that end in the next 64 KB page (BE9441 events 2 and 19) read an end offset lower than their start (the known page bug); every other event downloaded whole and verified. |
| 2026-10-25 | §7.2, §7.8, §6 | **MiniMate bench check, BE9441 (S338.17, mic disabled, serial cable). SFM read its 24-entry event index, listed 20 events, and downloaded 4.** Measured: (1) **§7.2: the 0x15 serial is a C string.** `"BE9441\x00?"`: a six-character serial leaves a stray byte after its NUL. (2) **§7.8: every A5 reply echoes the address it answers at `data[2:6]`.** The metadata pages come back as `01 11 10 02` and `01 11 10 04`; sample chunks as their own address, e.g. `01 11 66 6a`. The event-1 walk fetches the metadata pages as frames 1 and 2. A non-first event's walk fetches none and goes straight from the probe to sample chunks. SFM's body builder assumed metadata pages in every stream, so every non-first event it assembled was 2 bytes short and decoded truncated; it now checks the echoed addresses. The bug was in SFM's assembly; the protocol was as already documented. (3) **§6: the unit boots when its serial port opens.** It sent `Operating System` ~3 s after the port opened (twice) and ignored a POLL sent before that. After a mid-download reboot it answered 8.8 s after its banner (one data point). (4) **The unit rebooted once mid-download.** The chunk at 0x7D06 got one stray `0x41`, then silence, then the banner 11 s later. Cause unknown, inferred not measured: battery 6.33–6.37 V, a firmware reset. ⚠ **RETRACTED 2026-10-26:** the cause is measured, and it was our request. The chunk request had a bare 0x02 checksum. See the 2026-10-26 row. (5) The event index said 24 while the header walk listed 20 full records. **Inferred:** the other 4 are monitor-log entries. Single-shot events at 4096 sps with a 5 s record give **21,504 samples per channel** (5 s record + 0.25 s pre-trigger = 5.25 s at 4096 sps), all three channels equal, peaks equal to the unit's own 0C values. |
| 2026-10-17 | §7.6.1 | 🔶 **OPEN — the 6-byte "stable anchor" may be two settings at their defaults, not a constant.** Series IV's `0x1A` has the same field order as the S3 compliance block, and a keypad diff pass on a Micromate (UM20147) measured the bytes in the anchor's position: `[f32 BE pre-trigger, negative seconds][record stop mode, 00 00 = Fixed]`. `be 80 00 00` is exactly −0.25 s. If S3 matches — **inferred, not measured on S3** — then any S3 unit set to Record Stop Mode = Auto (a basic Blastware Compliance Setup option) or a non-default pre-trigger loses the anchor, and `client.py` silently decodes no recording mode / sample rate / interval / record time and skips them on write. No S3 capture has ever been taken in Auto stop mode (see the 2026-03-09 Auto Window rows), which would explain why the anchor never broke. To settle: one BW capture with Record Stop Mode = Auto. See `docs/micromate_protocol_reference.md` → *The `0x1A` field map from a keypad pass*. |
| 2026-08-26 | S7.6.2, S15 | **MULTI-INTERVAL HISTOGRAM BLOCKS - sub-minute intervals pack several per block.** The device always writes one minute of data per block, so a shorter histogram interval means more intervals packed into a longer block: 1 min -> 1 (the standard 32-byte block), 15 s -> 4 (stride 92), 2 s -> 30 (stride 612), with `stride = 12 + n * 20`. Each 20-byte record holds 8 x uint16 **little**-endian values (peak/half-period per channel) plus a 2-word tail whose first word is `0000` on every real interval. The standard block is big-endian - the variant is not. This recovers **415 files** (216 on BE18193 at 2 s, 199 on BE9440 at 15 s) that previously decoded to nothing, and before that were being accepted by the WAVEFORM codec and returning garbage up to 400x the device-reported PPV. |
| 2026-08-25 (3) | S7.6.1, S15 | **THE WAVEFORM BODY IS A RECORD CHAIN, NOT A TAG STREAM — supersedes the segment-header model entirely.** Records are self-delimiting: `off+2` is a uint16 BE length and `next = off + 2 + len`; the chain ends on a record whose chan_id is `0x06`. `off+8` holds a 3-valued mode enum - `02 00` (14-byte header, anchors, cumulative deltas), `01 00` (10-byte, no anchors, ABSOLUTE values), `00 03` (10-byte, no tags at all, raw 12-bit absolute). **`40 NN` is an ordinary int16 BE data block of length 2*NN+2**, never a header; reading it as a 2*NN+16 header is what made walks drift, and the 'variable prefix' of 0/2/4/6/8 bytes reported earlier the same day was walker drift, exactly `4 - (old_stop - true_record_start)`. Verified: chain terminates on `06` in 1387/1388 files; all four channels equal length in **1388/1388** (was 156/1388); ASCII sample-count exact 72/75 -> **75/75**, fully exact 70/75 -> **73/75**; device PPV on a live decode **1306/1306** waveform (mean abs ratio error 0.00000) and **4458/4459** histogram. Also eliminated the walker-over-read class: 24 of those files were histograms the waveform codec was wrongly accepting. The superseded model is retained as `decode_waveform_legacy` because `micromate/idf_file.py` pins it for Thor IDFW body-offset search. |
| 2026-08-25 (2) | S7.6.2, S15 | **HISTOGRAM BLOCK IS BIG-ENDIAN + terminal block tail.** The 32-byte histogram block's per-channel fields are uint16 **big-endian** (`T_peak` [5:7], `T_halfperiod` [7:9], `V_peak` [9:11], `V_halfperiod` [11:13], `L_peak` [13:15], `L_halfperiod` [15:17], `M_peak` [17:19], `M_halfperiod` [19:21]); only `block_ctr` [2:4] is little-endian. The marker is `block[4]` alone - the previous uint16 LE marker test at [4:6] forced `block[5] == 0` and thereby capped every geo peak at 255 counts (1.275 in/s), silently clipping larger peaks. The byte previously documented as a per-channel "annotation" is the high byte of the big-endian half-period, which is why it was non-zero exactly on sub-Hz intervals. Separately, the **final block of each stream carries tail `9c 06 00 42`** rather than `1e 0a 00 00` and holds arbitrary bytes at [21:23]; rejecting it dropped the last interval of nearly every histogram. Verified against 1211 production histograms paired with their Blastware ASCII exports: 1211/1211 decode exactly, plus 842,442 per-interval frequency comparisons with zero mismatches (previously 1 of 1196 files fully correct). |
@@ -552,6 +559,8 @@ Unit 2: serial="BE11529" trail=70 11 firmware=S337.17
> ❓ **Still unknown:** `trail[0]` is unit-specific. Does not derive from serial string via sum, XOR, or modulo. Possibly written at factory calibration. Needs a third unit or write-command capture to determine.
> ⚠ **2026-10-25 — AMENDED (measured, BE9441).** The 8-byte serial field is a **C string, not null-padded**. A six-character serial leaves a stray byte after its terminator: BE9441 sends `42 45 39 34 34 31 00 3f` = `"BE9441\x00?"`. Stripping trailing NULs alone keeps the `?`; cut at the first NUL. Every unit seen before had a seven-character serial, which fills the field exactly to the terminator.
### 7.3 Full Config Response (SUB FE) — 0x98 bytes
| Offset | Raw | Decoded | Certainty |
@@ -702,6 +711,14 @@ the anchor).
> reconfigured (e.g. 15 min = `\x03\x84`). Only the 6-byte suffix is constant.
> Code in `client.py` uses `buf.find(b'\xbe\x80\x00\x00\x00\x00', 0, 150)`.
> 🔶 **2026-10-17 — the 6-byte suffix may not be constant either (INFERRED from Series IV).**
> On a Micromate the same position holds `[pre-trigger f32 BE, negative seconds][record stop mode]`,
> measured setting by setting: `be 80 00 00` = −0.25 s, and `00 00` = Fixed (Auto reads `00 01`).
> Every S3 unit this anchor was confirmed on would have been at those defaults. If S3 shares the layout,
> a unit in **Record Stop Mode = Auto** returns `be 80 00 00 00 01`, `find()` returns −1, and the four
> anchor-relative fields silently go undecoded. **Not yet measured on S3** — one BW capture in Auto
> mode settles it. Until then, treat a missing anchor as this, not as DLE jitter.
> ✅ **2026-04-02 — CORRECTED:** Search range was `cfg[40:100]`. With the
> compliance-config orphaned-send bug fixed (§7.6.2), the 44-byte accidental
> header padding is gone and the anchor now appears at `cfg[11]`. Search range
+408
View File
@@ -0,0 +1,408 @@
# Spec — a live client for Series IV (Micromate)
Drafted 2026-09-26, ahead of implementation. The protocol work is finished; this
is the plan for turning `docs/micromate_protocol_reference.md` into code SFM can
run.
**Read that document first.** Everything here assumes it, and every constant
below is sourced from it rather than restated with justification.
---
## Goal and scope
`micromate/` is codec-only today — `idf_file.py`, `models.py`, the report
writers. There is no way to talk to a unit. This adds the live half, mirroring
`minimateplus/`.
**In scope, first pass:**
- connect over TCP (a field modem) or serial/USB (a bench unit)
- identify a unit, read its state, clock, memory and setups
- walk the event chain and download events
- return `Event` objects the existing codec already understands
**Explicitly out of scope, first pass:**
- ⚠ **Any write.** Setups, schedules, call-home config, monitoring start/stop,
and per-event delete are all mapped, and none of them will be implemented
here. **No command has ever been originated against a unit by this project**
— every write observed was performed by THOR while we recorded. Keeping that
true through the read client is deliberate: it means the first thing we ever
send to a customer's instrument is a decision someone made on purpose, not a
side effect of a client that happened to grow a method.
- the inbound call-home session — still the one protocol unknown
---
## Layout
```
micromate/
framing.py NEW frame building, response parsing, checksum
protocol.py NEW one method per wire command, returns raw payloads
client.py NEW high-level API, returns models
idf_file.py (existing — decodes what 0x5A returns, unchanged)
models.py (existing — extend, do not fork)
```
**Transport is reused, not rewritten.** `minimateplus/transport.py` is
byte-level and protocol-agnostic — `BaseTransport`, `SerialTransport`,
`TcpTransport`, plus `read_until_idle()` which already handles the RV50/RV55
habit of emitting `\r\nRING\r\n\r\nCONNECT\r\n` to a caller. Import it.
⚠ Do **not** import `minimateplus.framing`. The two framings differ in ways
that look small and are not, and a shared module would accumulate `if series ==`
branches until neither case is readable.
---
## `micromate/framing.py` — ✅ BUILT 2026-09-27
Implemented, with `tests/test_micromate_framing.py` (31 tests, all passing).
**Two things in this section as originally drafted were wrong**, and both were
caught by measuring against the captures before writing code rather than after.
They are left in place below, struck through, because both are the kind of
mistake that would be made again.
### Requests
~~Series IV accepts Series III request frames unmodified. The simplest correct
implementation re-exports the builder rather than duplicating it:~~
```python
from minimateplus.framing import build_bw_frame # ✗ WRONG — 161/218
```
⚠ **`build_bw_frame` reproduces only 161 of Thor's 218 captured read frames.**
The payload layout is identical; the stuffing is not. A Micromate escapes
**four** byte values — `0x02`, `0x03`, `0x04`, `0x10` — where Series III
escapes one. The frames this breaks are **every `SUB 0x5A` download**
(`offset = 0x0400` → a literal `0x04` in `offset_hi`) and the scheduler enable.
An unescaped `0x03`/`0x04` terminates the frame early, so the unit just does not
answer.
`build_request()` with the correct escape set reproduces **218/218**.
✅ **Settled: `0x10` inside params needs no special handling.** The planned
`NotImplementedError` guard is unnecessary — Thor sends
`params = 00 00 10 00 …` on `SUB 0x5A` in five captured frames and the wire
carries an ordinary doubled `10 10`. One rule covers the whole payload.
### Responses — where Series III's parser cannot follow
| | Series III | Micromate |
|---|---|---|
| frame start | `DLE STX` | **bare `STX`** |
| `payload[1]` | `0x10` | `0xC5` (Blastware fw) / `0x03` (Thor fw) |
| destuffing | `DLE+ETX` kept as literal inner-frame data | **`10 XX` → `XX`, uniformly** |
The first row is why `S3FrameParser` returns nothing at all on Series IV traffic:
it scans for `DLE+STX`, which never appears.
The third is a genuine **simplification** — no inner-frame carve-out. Validated
by checksum across every capture in `bridges/captures/9-24-26 - micromate2/`:
four candidate destuffing rules were tried, and only this one makes all frames
validate.
### Checksum
```python
def checksum(payload: bytes) -> int:
return sum(payload) & 0xFF # payload already de-stuffed
```
~~The DLE-aware variant, same as Series III's `5A` and write frames.~~
⚠ **Plain SUM8, not the DLE-aware variant** — 251/251 both directions. The
DLE-aware form is the right answer paired with *Series III* de-stuffing, which
leaves an escaped byte in the payload as two bytes. De-stuffing `10 XX → XX`
already removes the `0x10`, so excluding it again subtracts the correction
twice, and the result disagrees with the wire on **55 of 251** captured
responses — every frame holding a literal `0x10`.
`scratch/mm_frame_parse.py` shipped with exactly that pairing. It looked clean
only because it accepts a frame matching *either* rule, so it labelled those 55
`SUM8` and never flagged one bad. "Zero bad checksums" was true and carried no
information. Fixed there too.
### ⚠ The SUB byte can be escaped
When a SUB's value is `0x02`, `0x03`, `0x04` or `0x10` it arrives as `10 XX`.
Reading it positionally without destuffing reports `0x10`. This bit once
already — `SUB 0x02` was logged as `SUB_10` for an afternoon. Destuff first,
then index.
### Response shape
```python
@dataclass
class MicromateFrame:
sub: int # response SUB; request = 0xFF - sub
flags: int # 0xC5 Blastware line, 0x03 Thor line
page_hi: int
page_lo: int
data: bytes # payload[5:], checksum stripped
checksum_valid: bool
@property
def request_sub(self) -> int: # 0xFF - sub
@property
def page_key(self) -> int: # uint16 BE at payload[3:5]
@property
def firmware_line(self) -> str: # "blastware" | "thor" | "unknown"
@property
def probe_length(self) -> int | None: # uint16 BE at data[3:5] (= payload[8:10])
```
⚠ **`probe_length` is a uint16 BE.** Read as a single byte it under-reads
`SUB 0x1A` by 47x — 44 against a true 2092. This is the single most expensive
mistake available in this protocol and it has already been made once.
Renamed from `declared_length`, because it is **only meaningful in the reply to
an `offset = 0` probe** — and Thor never probes. Across all 251 captured
responses the field reads 0 or a page count, never a length, precisely because
that session is single-step reads throughout. `page_key` is the field that
carries meaning there. The only genuine probe reply we hold is the POLL one
preserved in `scratch/fake_unit.py`.
`MicromateFrameParser` mirrors `S3FrameParser`: `feed(bytes) -> list[frame]`,
accumulates in `.frames`, `reset()`, and keeps the `bytes_fed` counter (it is
what distinguishes "no bytes at all" from "bytes but no complete frame" on a
timeout, and that distinction earned its keep during the Series III work).
---
## `micromate/protocol.py` — ✅ BUILT 2026-09-27
Implemented, with `tests/test_micromate_protocol.py` (35 tests). Reads only;
nothing here writes, erases or changes monitoring state.
The tests replay Thor's captured responses through a scripted transport and
assert **the bytes we emit are the bytes Thor emits** — including a full replay
of the six-event download session, all 56 `0x5A` frames byte-for-byte. That is
a stronger guarantee than "our parser understands the device": a passing test
means a real unit has already answered exactly that frame.
One method per command, returning raw payload bytes. No interpretation — that
belongs in `client.py`.
**Reads use `offset = 0xFFFF`** and return the whole block in one response;
Series III's two-step probe/data dance is unnecessary. `POLL` is the exception,
taking its data length. Per-command offsets, all observed:
| command | SUB | rsp | offset | returns |
|---|---|---|---|---|
| poll | `0x5B` | `0xA4` | `0x0030` | device string, model |
| serial | `0x15` | `0xEA` | `0x000A` | `UM12947` |
| device info | `0x01` | `0xFE` | `0xFFFF` | firmware, calibration |
| state | `0x49` | `0xB6` | `0xFFFF` | `data[11]`: non-zero = monitoring |
| monitor status | `0x1C` | `0xE3` | `0xFFFF` | flag, **device clock**, battery, memory |
| storage range | `0x06` | `0xF9` | `0xFFFF` | event storage extent |
| active setup name | `0x41` | `0xBE` | `0xFFFF` | `TEST1.mmb` |
| first setup | `0x3F` | `0xC0` | `0xFFFF` | setup-list walk head |
| next setup | `0x40` | `0xBF` | `0xFFFF` | …until an empty name |
| compliance config | `0x1A` | `0xE5` | `0xFFFF` | ~2103 B setup block |
| call-home config | `0x2C` | `0xD3` | `0xFFFF` | 137 B |
| arm event | `0x93` | `0x6C` | — | before every event |
| first event | `0x1E` | `0xE1` | `0xFFFF` | key + size |
| next event | `0x1F` | `0xE0` | `0xFFFF` | key + size |
| event record | `0x0C` | `0xF3` | `0xFFFF` | 221 B — project, location, peaks |
| ~~event header~~ **monitor log** | `0x0A` | `0xF5` | `0xFFFF` | ⚠ 297 B, a **walk** — see below |
| bulk download | `0x5A` | `0xA5` | computed | **the `.IDFW` verbatim**, 1024 B at a time |
⚠ **Corrected 2026-09-27, from Thor's frames.** Three rows of the table above
were wrong or incomplete, and the last one is a different command than labelled:
- **`0x0A` is the monitor-log walk**, not a keyed "30 B list record" read. The
*same request repeated* returns successive 297-byte records — serial, mode,
thresholds — until an 11-byte ack ends the list. The device holds the cursor;
nothing in the request selects a record. Series III reaches this data through
a record-type discriminator on its event chain; here it has its own cursor and
the event chain never sees it.
- **`0x1E`/`0x1F` carry token `0xFE` at `params[7]`.** The reference documents
all-zero params (our own probing, which also worked). Thor's form is the one
with mileage.
- **`0x01` has no Thor frame behind it** — it is never read in any captured
session. Its `0xFFFF` comes from our probes.
And one useful negative: **no `SESSION_RESET` (`41 03`)**. Series III needs that
2-byte signal or a monitoring unit will not answer `POLL` over TCP. Thor never
sends it — zero occurrences across 8 sessions, including 40 frames exchanged
with a unit that *was* monitoring.
⚠ **`SUB 0x1C` is 4 bytes longer on the Thor firmware line** (`0x30` vs `0x2C`).
Parse **forward** from `declared_length`, never backward from the end — Series
III reads battery and memory from the end of that block, and doing so on a BD
unit yields a battery voltage of **577.92 V**.
⚠ **Test the monitoring flag for non-zero**, never against a constant. It has
read both `0x0E` and `0x0C` while monitoring.
### `0x5A` — a bounded chunk loop, and much simpler than Series III
⚠ **Corrected 2026-09-27.** This section said "no chunk loop — one request
returns the whole event", with `offset_word = 0x1000 + 2 * ceil(size / 512)`.
That describes our own 2026-09-23 probes, which set `offset_hi = 0x10`. **Thor
chunks**, and Thor's form is the one verified from bytes on disk:
```python
n = ceil(size / 1024) # size from the chain walk
for i in range(n):
offset = min(1024, size - 1024 * i) # a BYTE COUNT
params = key4 + bytes(6) if i == 0 else bytes(2) + pack(">H", 1024*i) + bytes(6)
file_bytes += response.data[11:] # response data is exactly offset + 11
```
Verified on all six bench events (4,076 → 13,424 B): `sum(offsets) == size`
exactly, with the predicted chunk count and final offset every time.
Still no arming ritual for `0x5A` itself, no `STRT` end-offset parsing and no
`TERM` frame — the simplification the original claim celebrated is real, it just
is not single-shot. (`SUB 0x93` arms the *chain walk*, before `1E`/`1F`, not
the download.)
The concatenated payload **is** the `.IDFW` file, byte for byte — so it feeds
`micromate.idf_file.read_idf_file()` and `/db/import/idf_file` unchanged.
⚠ Do not port the Series III `5A` walk. Its address arithmetic caused a 5x
over-read and a `> 64 KB` page-boundary bug that is *still open* on the Series
III side. None of that applies here: the chunk index is a byte offset into the
file, bounded by a size the device told us, and it cannot run past the event.
⚠ **`assert sum(len(chunk) - 11 for chunk in chunks) == size`.** A silently
short event is the failure mode this project has been bitten by repeatedly on
the Series III side, and here the check is free because the size is known up
front.
---
## `micromate/client.py` — ✅ BUILT (read half) 2026-09-27
`connect()`, `get_state()`, `get_active_setup()`, `list_setups()` plus
`MicromateDeviceInfo` / `MicromateState` in `models.py`. 26 tests, every
response constant a real captured data section.
⚠ **`connect()` is deliberately narrower than this spec asked for.** The spec
said to mirror Thor's `POLL → SERIAL → 0x49 → POLL` "because it is known-good".
Measurement showed the four-command form is Thor's *connection check*, present
in 3 of 8 sessions, and its fourth frame repeats its first — so `connect()`
sends the three reads that gather something. `0x01` is not read at all: Thor
never reads it, its layout is unmapped, and `firmware_line` comes free from any
response's flags byte.
Event-chain methods (`list_events`, `download_event`, `get_event`) are step 4
and not yet written; `MicromateProtocol.read_event_file()` already does the
download.
```python
class MicromateClient:
def __init__(self, transport: BaseTransport): ...
def open(self) / close(self) / is_open(self)
# identity and state
def connect(self) -> DeviceInfo # poll → serial → device info → state
def get_state(self) -> UnitState # monitoring?, clock, battery, memory
def get_active_setup(self) -> str
def list_setups(self) -> list[str] # 0x3F → 0x40… until empty
# events
def list_events(self) -> list[EventRef] # 0x93 → 0x1E → 0x1F… (key + size)
def download_event(self, ref) -> bytes # raw .IDFW/.IDFH
def get_event(self, ref) -> Event # download + decode via idf_file
```
`connect()` should mirror THOR's preamble (`POLL → SERIAL → 0x49 → POLL`) —
⚠ but note the reference records that **whether the unit requires it is
untested**. Do it because it is known-good, not because it is known-necessary,
and say so in the docstring.
`list_events()` returns the key *and* the size, because `download_event()` needs
the size to compute its offset word.
---
## Tests
**Offline, from captured bytes — no hardware.** This is the part worth doing
first, because it can be fully verified tonight's-captures-style before any unit
is involved.
```
tests/test_micromate_framing.py
```
⚠ `bridges/captures/` and `tests/fixtures/` are both gitignored, so tests must
not depend on files being present. **Embed the frames as hex constants** — they
are 19–138 bytes each. ✅ Done; what actually landed:
| case | source | why |
|---|---|---|
| POLL probe reply, 19 B | captured (via `fake_unit.py`) | shortest valid frame; the only real probe reply we hold |
| `0x5A` chunk, 138 B | captured | holds literal `0x10` **and** literal `0x41` — the checksum case, and proves ACK is not escaped |
| `0x49` state reply, 25 B | captured | a literal `0x02`, escaped |
| `0x48` file reply, 24 B | captured | escaped `0x04` in `data[0]` — one byte late without destuffing |
| 8 Thor request frames | captured | byte-for-byte against `build_request()`, incl. both `0x5A` forms and the scheduler enable |
| `probe_length = 0x082C` | **synthesised** | no probe reply for `0x1A` exists on disk — the 9-24-26 session never probes |
| Thor-line reply, `flags = 0x03` | **synthesised** | no 11.0BD capture is in the repo; built by flipping one byte of the real POLL reply |
| escaped checksum byte | **synthesised** | the shortest real one is 1,070 B, too long to embed for one assertion |
| truncated / corrupt / split-across-feeds | derived | parser must return nothing, flag rather than swallow, and survive any split point |
⚠ Synthesised frames are marked `SYNTH_`-style in the test and each says what it
stands in for and why no capture was available. Do not let that set grow
quietly: the `flags = 0x03` case in particular is the **only** coverage of half
the fleet, and it deserves a real 11.0BD capture the next time UM20147 is on a
bench.
Two corpus-backed tests run when the captures happen to be on the box and skip
cleanly otherwise: **251 response frames parse with zero bad checksums**, and
**`build_request()` reproduces 218/218 read frames**. The second is the test
that would have caught the escape-set error, so it is worth the skip marker.
⚠ Do **not** assert against `scratch/mm_frame_parse.py`'s output as the original
plan proposed. That script accepts either checksum rule and is wrong about
which one is right — using it as an oracle would have pinned the bug.
**Live, second:** against the bench unit on mint-mac via `mm_link.py`.
`connect()`, `list_setups()` (should return the 23 known names), `list_events()`,
then `download_event()` and assert the bytes decode and match a
`/db/import/idf_file` ingest of the same event.
---
## Order of work
1. ✅ `framing.py` + its tests — **done 2026-09-27**, 31 tests, offline
2. ✅ `protocol.py` + its tests — **done 2026-09-27**, 35 tests, offline
3. ✅ `client.py` + its tests — **done 2026-09-27**, 26 tests, offline
4. the event chain and `download_event()`
5. decode end-to-end and compare against a store event
Steps 1–2 need no hardware at all.
**Worth carrying forward.** Both steps began by measuring against the captures
rather than trusting this document, and both found errors in it — three in the
framing rules (the escape set, 26% of frames; the checksum, 22%; the `0x5A`
chunk model) and three more in the command table (`0x0A`'s meaning, the
`1E`/`1F` token, `0x01`'s provenance). All six fail quietly. The captures are on
disk and a measure-then-write loop costs about two minutes per rule, so keep
doing it for `client.py`'s field offsets — and treat this spec as a plan, not a
source.
---
## Open questions to settle while implementing
- ~~**Request param stuffing**~~ — ✅ settled 2026-09-27; no special handling.
- **Is the single-request `0x5A` form real?** Our 2026-09-23 probes set
`offset_hi = 0x10` and appeared to get a whole 11 KB event back, where Thor
chunks at 1024 B. Plausibly a distinct streaming mode that returns several
frames. One bench test settles it; implement Thor's form regardless.
- **Is THOR's preamble required?** Try one command cold and find out; it is a
two-minute test with the bench unit and it removes a ritual if unnecessary.
- **`Event` model fit** — Series IV carries fields Series III lacks (setup file
name, `LMic`/`SMic` channels). Extend `micromate/models.py`; do not fork the
shared `Event`.
- **Which `0x0C` fields to trust.** The peak float there runs 2–5% above
`max(T,V,L)` and is **not** the vector sum; its offset was inferred, not
established. The reference marks it do-not-rely-on — prefer decoded samples.
File diff suppressed because it is too large. Load diff
+135
View File
@@ -0,0 +1,135 @@
# USBM RI8507 / OSMRE Blasting Compliance Curve — Reference
Reference for the **velocity-vs-frequency blasting compliance chart** Blastware
draws on its Event Report ("USBM RI8507 And OSMRE"), and how seismo-relay
reproduces it. Implemented in [`sfm/compliance.py`](../sfm/compliance.py); the
spectral (FFT) side lives in [`waveform_fft.py`](../waveform_fft.py).
Reverse-engineered 2026-09-14 against 7 BE12844 (MiniMate Plus) events, each
with a Blastware Event Report + FFT Report as ground truth. Curve values from
USBM RI8507 Appendix B and 30 CFR 816.67.
---
## What it is
Two closely-related sources for the same limit curve:
- **USBM RI8507** — Bureau of Mines *Report of Investigations 8507* (Siskind
et al., 1980), *"Structure Response and Damage Produced by Ground Vibration
From Surface Mine Blasting."* The curve is **Figure B-1**, Appendix B
("Alternative Blasting Level Criteria"), p.73–74.
- **OSMRE / OSM** — the Office of Surface Mining Reclamation and Enforcement
codified it as **30 CFR 816.67, Figure 1**. "CFR" = the U.S. Code of Federal
Regulations. Same curve, regulatory force.
The chart plots each geophone channel's significant vibration cycles as
`(frequency, peak velocity)` points against this limit. A point **below** the
line passes; **above** fails.
---
## The limit curve
A structure has a resonance band (~4–12 Hz for whole structures) where it is
most vulnerable, so the safe velocity is **lower** at those frequencies and
**higher** away from them. The curve captures this by alternating two kinds of
bound:
- **Constant-velocity** segments — a flat horizontal line at a fixed PPV.
- **Constant-displacement** segments — a fixed peak *displacement* `d`. For
simple harmonic motion, peak velocity `v = 2πf·d`, so on a velocity-vs-
frequency **log-log** plot this is a straight line of slope +1 (velocity rises
with frequency). This is why the low- and high-frequency bounds are sloped.
### Two lines — structure type
RI8507 gives two lines for two interior-wall constructions (Table 13, p.67):
| line | construction | plateau PPV |
|---|---|---|
| **Drywall** (solid) | modern gypsum wallboard | **0.75 in/s** |
| **Plaster** (dashed) | older plaster on wood lath | **0.50 in/s** |
Plaster-on-lath is more damage-prone, hence the lower limit. You apply **one**
line depending on the monitored structure.
### The four segments (Figure B-1, p.74)
Going low → high frequency, each line is:
1. **Ultimate low-frequency bound** — constant displacement **0.030 in**
(`v = 2πf·0.030`). Only relevant below ~4 Hz.
2. **Plateau** — constant velocity **0.75** (Drywall) / **0.50** (plaster) in/s.
3. **Rising diagonal** — constant displacement **0.008 in** (`v = 2πf·0.008`),
climbing from the plateau up to the high-frequency cap.
4. **High-frequency cap** — constant velocity **2.0 in/s** above ~40 Hz.
The segments are drawn **continuous**: each bound is used over the frequency
range where it is the binding (lowest) limit, and consecutive bounds meet where
they are equal — so there are no vertical steps. Transition frequencies come
straight from the values (`f = V / (2π·d)`):
| transition | formula | Drywall | Plaster |
|---|---|---|---|
| 0.030 in → plateau | `V_mid / (2π·0.030)` | 3.98 Hz | 2.65 Hz |
| plateau → 0.008 in | `V_mid / (2π·0.008)` | 14.92 Hz | 9.95 Hz |
| 0.008 in → 2.0 in/s | `2.0 / (2π·0.008)` | 39.79 Hz | 39.79 Hz |
Because both lines share the same **0.008 in** rising diagonal, above ~15 Hz
they lie on the *same* line (both reach 2.0 in/s at ~40 Hz) — RI8507's literal
construction merges them there. Blastware renders the dashed line as a separate
parallel diagonal, but that is cosmetic: above ~15 Hz both structure types carry
the identical limit, so compliance is unaffected.
> ⚠ RI8507's *Table 13* is a simpler two-range criterion with a **sharp
> discontinuity at 40 Hz** (flat plateau, then a jump to 2.0). Figure B-1 is the
> **smoothed** version that adds the 0.008 in transition — that is the one drawn
> on reports and implemented here.
---
## The compliance scatter (the points)
The cloud is **not** the FFT spectrum. It is a per-cycle, time-domain measure by
the **zero-crossing method** (`channel_compliance_points`):
- Split the channel's waveform at its zero crossings.
- Each half-cycle contributes one point: **frequency** `= 1 / (2 · half-period)`
(from the samples between the two crossings), **velocity** `= peak |amplitude|`
in that half-cycle.
This yields ~90–110 points per channel, and — by construction — each channel's
**highest** point equals that channel's PPV. Verified against Blastware: the
cloud shape, density, and ceiling all match.
### Why not the FFT?
A broadband blast spreads its energy across many FFT bins, so no single bin
reaches the time-domain peak — the FFT amplitudes come out ~10× below the
compliance-chart velocities. The compliance chart is a *per-cycle peak* view;
the **FFT** is a separate analysis (Blastware's *FFT Report*), reproduced by
[`waveform_fft.py`](../waveform_fft.py) and used for the dominant-frequency
readout and the #10 FFT view — not for this scatter.
---
## Implementation
- `sfm/compliance.py`
- `limit_at(freq, curve)` — the limit PPV at a frequency (`curve` = `"Drywall"`
or `"Plaster"`); curves are data in `_CURVES`, so more standards can be added.
- `channel_compliance_points(samples, sps)` — the zero-crossing scatter.
- `draw_compliance_chart(ax, channels, sps)` — matplotlib rendering (both
limit lines + per-channel scatter, Blastware's tick scales and channel
markers: Tran `+` red, Vert `×` green, Long `o` blue).
- Tests: `tests/test_compliance.py`.
---
## Sources
- USBM **RI8507** (Siskind, Stagg, Kopp, Dowding, 1980), Appendix B / Figure B-1,
p.73–74; Table 13, p.67. (`ref-stuff/usbm-ri8507-ground_vibration.pdf`.)
- **30 CFR 816.67**, "Use of explosives: Control of adverse effects," Figure 1 —
<https://www.ecfr.gov/current/title-30/chapter-VII/subchapter-K/part-816/section-816.67>
+327 -3
View File
@@ -1,6 +1,7 @@
# Runbook — Recovering a wedged unit stuck in a call-home loop
**Original incident:** BE9558H at `166.246.130.1:9034`, recovered 2026-05-17.
**Incidents:** BE9558H at `166.246.130.1:9034`, 2026-05-17 (Method B) ·
BE12599 at `166.246.64.226:9034`, 2026-09-16 (Method A).
A field unit with a stuck-triggered geophone (or any hardware fault causing
constant event triggering) will record events back-to-back, and if Auto Call
@@ -14,6 +15,33 @@ This runbook describes how to break the loop and recover control.
---
## ⚠ Two cures for one disease — intercept first
Both incidents below are the **same failure**: a geophone offset crosses the
trigger level, the unit records back-to-back, ACH set to "after event
recorded" dials continuously, and the unit becomes unreachable because its
modem is in client mode almost all of the time.
There are two ways to get a Stop Monitoring command into it.
| | **A — intercept the call** (preferred) | **B — catch it between calls** (original) |
|---|---|---|
| Idea | Be the server it dials. Point the modem's Destination at our own ACH server and answer it. | Clear the Destination so it stops dialing, then race a Stop into the gap. |
| Needs inbound? | **No — the unit calls us** | Yes: working inbound TCP to the modem |
| Determinism | Deterministic — it dials every ~75 s, we only have to be listening | A race. BE9558H took ~7 h of attempts before one landed. |
| Tool | `bridges/ach_server.py --stop-monitoring` | `scripts/slow_drip.sh` |
| Proven on | BE12599, 2026-09-16 | BE9558H, 2026-05-17 |
**Method A is the standard procedure now.** The unit won't answer us because
it is on the phone — so stop dialing it and be the one it calls. It rings,
we pick up, take its data, and tell it to stop calling here.
Method B is kept because it is proven, and because A needs a listener the
modem can actually reach (public IP + forwarded port). When you have that,
don't race it — intercept it.
---
## Symptoms
- Terra-View / SFM `/device/info` either hangs or fails on `count_events()`.
@@ -31,9 +59,85 @@ If you see *all* of these, the unit is in this exact failure mode.
---
## Quick reference — how to recover
## Method A (preferred) — intercept the call
You need **ACEmanager access** to the unit's modem.
You need **ACEmanager access** and a host the modem can dial: public IP with
the listener's port forwarded to it.
### A1 — start the listener BEFORE touching the modem
```bash
cd /home/serversdown/seismo-relay
tmux new -s rescue
.venv/bin/python -u bridges/ach_server.py --port 12345 \
-o bridges/captures/<unit>-diag --stop-monitoring -v
```
⚠ **Listener first, always.** A Destination pointed at a dead port is the
worst state available — the device still dials, the modem still flips to
client mode, inbound stays blocked, and nothing gets delivered.
Do **not** add `--events-only` (it silently breaks dedup — see gotchas), and
do **not** add `--disable-ach` yet (see A4).
### A2 — point the modem at it
ACEmanager → **Serial → Port Configuration**:
| Field | Set to |
|---|---|
| **Destination Address** | the listener's public IP |
| **Destination Port** | the listener's port (e.g. `12345`) |
Apply. The modem auto-dials its Destination whenever serial data arrives
while the serial port is closed — so the unit's own retry cycle now lands on
you instead of nowhere.
### A3 — answer, and stop the bleeding
Within ~75 s you should see a call-in. `--stop-monitoring` fires SUB 0x97 at
step 1.5 — after the handshake, **before** the event walk — so the recording
halts at the earliest possible moment in the session. Confirm via
`rescue.json` in the session directory:
```json
{"peer": "166.246.64.226:60921", "stop_monitoring": "ok"}
```
That is the bleeding stopped. Everything after this is cleanup.
### A4 — drain the backlog, THEN disable ACH
⚠ **Order matters, and it is counter-intuitive.** Stopping monitoring also
removes your call-in trigger: ACH fires on "after event recorded", so with
recording stopped the unit has no reason to dial again. The backlog sitting
in its memory does **not** re-arm it.
So if the stored events are worth keeping — and on a fault unit they usually
are, they're the evidence — drain them across however many call-ins it takes
*before* you silence it. Only then add `--disable-ach` (or use
`scripts/rescue_device.sh <host> <port> --no-erase`).
If the unit has gone quiet and you still need it, cycling the modem produces
a call-in, and a unit with a scheduled daily call will dial at its configured
time regardless.
### A5 — restore the Destination, and confirm you did
Put `Destination Address` back to `0.0.0.0` (or the office Instantel ACH
server) once you are finished, and only stop the listener after that is done.
### A6 — do NOT re-enable ACH until the hardware fault is repaired
Otherwise the loop restarts the moment monitoring resumes and you run this
runbook again.
---
## Method B (fallback) — catch it between calls
The original 2026-05 procedure. Use when you cannot stand up a listener the
modem can reach. You need **ACEmanager access** to the unit's modem.
### Step 1: stop the modem's mode-flipping
@@ -253,3 +357,223 @@ service).
Total time from "i was wondering if its possible to" first attempt to
recovery: ~7 hours of intermittent debugging across one evening.
---
# Second incident — BE12599, 2026-09-16/17
**Unit:** BE12599 at `166.246.64.226:9034`, RV50, job *I-80 North Fork Bridge
— Abut 1 West* (Fay Company). Same job as BE9558H, which is a coincidence.
**Fault:** the connector fault documented in `docs/offset_investigation.md`
§8e progressed until the Tran pedestal reached **0.400 in/s** — its trigger
level. Constant triggering → constant recording → ACH "after event recorded"
→ continuous dialing. Same disease as BE9558H.
**Same disease, inverted cure.** Method B's Step 1 *did* work — clearing the
Destination stopped the dial-outs, confirmed in the ALEOS log. It was Step 2
that didn't land, and rather than keep racing we turned the rescue around:
gave the unit a different server to call, and answered it.
Total time ≈ 5 h, of which ~90 min went to two red herrings documented below.
Much of the rest was rediscovering the May procedure, which is why the
"two cures" table now sits at the top of this file.
---
## Turn on ALEOS_SERIAL debug FIRST
This is the single highest-value diagnostic and it should be step zero on any
future incident. ACEmanager → **Admin → Log → ALEOS_SERIAL log level →
DEBUG**, then view the serial log.
It is the only thing that tells you what the *device* is actually saying.
Everything before we did this was guesswork.
## What the log showed — the unit is on the phone
Every ~75 seconds, verbatim:
```
ALEOS_SERIAL_HIF: 29 byte(s) in buffer: 'ATQ1^MATE0^MATS0=2^M^MRADIO RING^M'
ALEOS_SERIAL_HMC: TCP recvhost fd 65535 len 29 state TCPMode::kClosed
ALEOS_SERIAL_HMC: tcpmode trying to send to invalid socket
ALEOS_SERIAL_HMC: Connect to IP: 0.0.0.0 Port 0
ALEOS_SERIAL_HMC: Initialize Auto answer on port 9034
ALEOS_SERIAL_HMC: Cannot connect to 0.0.0.0
```
Read that carefully:
- `ATQ1` (quiet) / `ATE0` (echo off) / `ATS0=2` (auto-answer after 2 rings).
**There is no `ATD`.** The device is not dialing — it is trying to
*configure* its modem.
- The modem's serial port is in TCP data mode, so it never interprets these
as AT commands. It treats them as payload and tries to ship them to a TCP
socket that does not exist.
- The device therefore never receives `OK`, never progresses, and **retries
the identical 29 bytes forever**.
**While it is in this state it is busy placing a call, not listening for
us.** This is almost certainly what BE9558H was doing too — we simply never
turned on ALEOS_SERIAL debug in May to look. It is not a different disease;
it is the same one, seen properly for the first time.
It is also the argument for Method A in one picture: the unit is mid-dial
every ~75 s, and our inbound Stop has to thread the gaps between those
attempts. Give it somewhere to dial and the problem inverts into a
deterministic one.
### Why `slow_drip` lied
`slow_drip` returned the *success* signature except for the one field that
mattered:
```json
{"duration_s":120.0,"drips_sent":38,"bytes_sent":920,
"bytes_received":0,"send_error":null}
```
Full duration, no broken pipe — but zero bytes back. Cause is in the log
above: each 75 s cycle re-runs `Initialize Auto answer on port 9034`, which
orphans the held session (`data in for unknown reason 3 removing from
select`, `OnMsg recv error: 107 - Transport endpoint is not connected`). Our
local TCP stayed open so `sendall` never raised — but the modem stopped
bridging after the first re-init, so every drip after that went into a socket
nobody was reading.
⚠ **`send_error: null` + full duration is NOT success. Only
`bytes_received > 0` is success.**
⚠ **In fairness to slow_drip: it got exactly one attempt here**, run ~90 s
after a modem reboot, with a dead session visible in the log at 20:19:17 in
that same window. BE9558H took hours of attempts before one landed. Method B
was not ruled out on BE12599 so much as abandoned in favour of something that
doesn't need luck.
---
## ⚠ Two red herrings that cost ~90 minutes
### 1. The trusted-IP whitelist (this was the real reason inbound never worked)
The RV50s run with **Security → Trusted IPs (Friends List) enabled**. A
source IP that is not on the list is dropped **silently** — inbound presents
as `Connection error: timed out`, never a refusal.
Brian's dev-box public IP is **dynamic** and had changed, so `tmi-dev` was no
longer whitelisted. Every inbound attempt failed identically across four
different modem and device states, which looked exactly like the BE9558H
mode-flipping symptom and sent us chasing modem configuration for over an
hour.
**Check this before diagnosing anything else.** Note that SFM in Docker
egresses via the *host's public IP*, not its LAN IP.
### 2. A 502 from SFM does not mean TCP connected
`sfm/server.py` raises **502 for both** failure classes:
```python
raise HTTPException(status_code=502, detail=f"Protocol error: {exc}")
raise HTTPException(status_code=502, detail=f"Connection error: {exc}")
```
We read an early 502 as "TCP connected, modem bridged, device mute" and built
a whole theory on it. It was almost certainly a connect timeout.
**Always read the `detail` string** — "connect failed" and "device didn't
answer" are completely different problems and the status code will not
separate them.
---
## What actually worked — invert the direction
The key observation is in the log above:
> `TCP recvhost ... state TCPMode::kClosed` → `Connect to IP: 0.0.0.0 Port 0`
**The modem auto-dials its Destination whenever serial data arrives while
closed.** So instead of fighting for inbound, give it somewhere to dial:
point `Destination Address` at our own `ach_server` and the device's own
75-second attempts become **device-initiated sessions the modem bridges
correctly**. No race, no contention, worst case a 75-second wait.
### Procedure
1. **Run the rescue server** on a host the modem can reach (public IP +
forwarded port):
```bash
cd /home/serversdown/seismo-relay
.venv/bin/python -u bridges/ach_server.py --port 12345 \
-o bridges/captures/<unit>-diag --stop-monitoring -v
```
2. **Point the modem at it** — ACEmanager → Serial → Port Configuration →
`Destination Address` = your public IP, `Destination Port` = 12345.
3. **Wait for the call-in.** `--stop-monitoring` fires SUB 0x97 at step 1.5,
after the handshake and *before* the event walk. Confirm via
`rescue.json` in the session directory:
```json
{"peer": "166.246.64.226:60921", "stop_monitoring": "ok"}
```
4. **Restore the modem's Destination** once you are done, then finish the
device side (disable ACH, erase) through whichever channel works.
On BE12599 the first call-in landed at 20:58:11 and reported
`stop_monitoring: ok`; a second at 20:58:20 confirmed it. `is_monitoring:
false` was still true **6½ hours later** — the fix is durable.
---
## Hard-won gotchas (do not re-derive)
- **Never leave the Destination pointed at a host with nothing listening.**
That is the worst state available: the device still dials, the modem still
flips, inbound stays blocked, and nothing is delivered. An 8-minute gap
with the listener down produced a spurious inbound timeout that cost
another round of misdiagnosis.
- **Stopping monitoring removes your call-in channel.** ACH is "after event
recorded"; no new events means no new dials. The backlog sitting in memory
does *not* re-arm it. After a successful stop the unit goes quiet and you
need the modem cycled (works — produced a call-in), the scheduled daily call
(BE12599 calls at **05:00:14 device-local**, per §8e), or working inbound.
**Plan the order before you fire the stop.**
- **`--events-only` silently breaks dedup.** It skips the device-info step,
so the serial is never read; `ach_state.json` then keys on
`peer:ephemeral_port`, which is unique per connection. Every session looks
like a new unit, starts from key 0, and re-downloads the same event. Four
sessions on BE12599 downloaded the identical event four times and made zero
progress on the backlog. Events also file as `serial=UNKNOWN` with a
`M000…` BW filename (serial_numeric 0) instead of `N599…`.
**Do not use `--events-only` when you intend to download anything.**
- **`/device/events/index` reported `lifetime_count: 0`** on a unit with years
of history. Suspected decode bug in the SUB 0x08 field offset — do not
trust that number. The 88-byte payload is preserved in the `raw_hex` field
if someone wants to chase it.
- **Memory used cross-checks the event keys exactly:**
`last_key − buffer_start = memory_total − memory_free`. On BE12599:
`0x011230ec − 0x01110000 = 78,060` and `983,028 − 904,968 = 78,060`.
Useful sanity check that you are reading the keys right.
---
## Final state (2026-09-17 ~01:30 local)
- `is_monitoring: false`, held 6½ hours
- Battery 6.76 V
- Memory 78,060 / 983,028 bytes used (8%)
- `first_key 01121728`, `last_key 011230ec` — ~6.6 KB of addressable event
chain, roughly 3 events
- ACH still **enabled** — to be disabled after the backlog is preserved
- Modem Destination still pointed at tmi-dev — to be restored
- ⚠ **Do not re-enable ACH until the connector is serviced.** Tran is still
sitting at 0.400 and the loop restarts the moment monitoring resumes.
+150
View File
@@ -0,0 +1,150 @@
# SFM — where it actually stands as a tool
**Status as of 2026-09-20 (v0.31.0).** This is the honest assessment, not the
roadmap — `README.md § Roadmap` covers where it is *going*. Expect this file to
go stale; re-date it when you revise it.
---
## The framing
SFM is **three different things wearing one name**, at three very different
levels of maturity:
| | what it is | maturity |
|---|---|---|
| **The codec library** | `minimateplus/`, `micromate/` — bytes in, `Event` out | **Production.** Verified per-sample at scale. |
| **SDM — the data side** | the DB, waveform store, `/db/*`, ingest | **Production.** Terra-View depends on it daily. |
| **SFM — the device side** | `/device/*`, live connections to units | **Emergency-grade.** Works, but manual, unauthenticated, and thinly tested. |
| **The lab** | `seismo_lab.py`, `scratch/`, the Inspector | **Research artifacts.** Useful, not products. |
Brian's own description — *"right now it's an emergency tool and a research
project"* — is accurate, and it applies specifically to the **device side**.
The data side is not an emergency tool; it has been carrying production for
months.
Most confusion about "is SFM reliable?" comes from answering for the wrong
tier.
---
## 1. What you can rely on
### Production-grade — trust it
- **Series-3 decode.** 14,338 / 14,338 files decode per-sample exact against
preserved Blastware ASCII exports, 45 units, files back to 2018.
- **Series-4 (Thor) decode.** 1,057,536 / 1,057,536 geo samples exact against
Thor's own CSV exports; production IDFW 575/575 with zero truncations.
- **Histogram decode.** 1,211 / 1,211 production histograms exact, including
842,442 per-interval frequency comparisons with zero mismatches.
- **The ingest path.** `/db/import/blastware_file` and `/db/import/idf_file`
fed by the watchers — this is how prod actually gets its data, and it has
been running unattended for months.
- **`/db/*` read API.** Always-on, consumed by Terra-View for every fleet
listing, event detail and report.
- **The waveform store** — `.h5` + `.sfm.json` sidecars + retained raw
binaries, with operator review state preserved across regeneration.
- **`bridges/ach_server.py`** — speaks the full BW protocol to calling units.
Proven in the field, including as a rescue tool (see the runbook).
### Emergency-grade — works, but you are the error handling
- **`/device/*` live endpoints.** They do what they say. But they are
synchronous, unauthenticated, and a single cellular download can exceed the
60 s timeouts that sit in front of them.
- **The rescue ladder** (`rescue`, `stop_monitoring_*`, `events/erase`).
Each has worked in a real incident — but each has been used a handful of
times, by one person, with the runbook open.
- **The standalone webapp.** Perfectly usable, and as of v0.31.0 the cheap
probes and rescue actions are reachable without curl. No auth of any kind.
### Research artifacts — useful, not products
- **`seismo_lab.py`** — 2,789 lines of Tkinter (Bridge / Analyzer / Query DB /
Inspector). Desktop-only, single-user, no tests.
- **`scratch/`** — the verification harnesses (`verify_against_ascii.py`,
`verify_thor_against_csv.py`) and the offset detector (`offset_scan3.py`).
These produced the numbers the production claims rest on, so they matter —
but they are analysis scripts, not maintained code.
- **`docs/offset_investigation.md`** — an open investigation, not a feature.
---
## 2. What to use when
| you want to… | use | notes |
|---|---|---|
| Know if a unit is monitoring / its battery / memory | `GET /device/monitor/status?force=true` | ~2 s |
| Know whether ACH is on | `GET /device/call_home` | ~2 s. **Not** `/device/events`. |
| See how full a unit's buffer is | `GET /device/events/storage_range` | ~2 s, no chain walk |
| Stop a runaway unit | Diagnostics tab → Stop Monitoring | see the runbook first |
| Reach a unit that will not answer | **point its modem at an `ach_server` and answer its call** | runbook Method A — do not race it |
| List a unit's stored events | Events tab → Load events | **slow**, and broken past 64 KB (below) |
| Get event data into the DB | the watcher → `/db/import/*` path | not the live walk |
The single most useful habit: **the cheap probes are cheap and the event walk
is not.** Reaching for `/device/events` to answer a yes/no question about a
unit is the mistake that motivated the v0.31.0 webapp changes.
---
## 3. Known issues
| issue | impact | status |
|---|---|---|
| **5A walk dies once a unit's buffer crosses 64 KB** | `/device/events` 500s; event body never downloads | Known, documented in `CLAUDE.md`. Needs a BW capture of a spanning event to fix properly. |
| **No auth on SFM at all** | 21 `/device/*` endpoints, including destructive ones, open to anything that reaches the port | Design agreed (Terra-View as authenticated jump host); not built. |
| **Swagger try-it-out is live on destructive endpoints** | `POST /device/events/erase` is one click away at `:8200/docs` | Partially mitigated: the webapp's erase now requires typing the serial. `/docs` itself is unguarded. |
| **`SUB 0x08` lifetime counter reads 0** | `/device/events/index` returns a meaningless number | Suspected field-offset bug. Surfaced in the UI as "unreliable". |
| **Long device operations are synchronous** | 60 s timeouts in `routers/sfm.py` and the reverse proxy; a full download exceeds both | Known design constraint. Must be POST-starts-job / GET-polls before any remote lab. |
| **`backfill_sidecars.py --force` silently inserts DB rows** | store files with no DB row get one; the dry-run does not report the count | Known. Avoid `--force` — `TOOL_VERSION` gates regeneration anyway. |
| **14 sensitive-range files show an exact 8× discrepancy** | 10.0 / 1.25 — a units problem, not a decode problem | Open, not blocking. |
| **16 failing tests on `dev`** | 15 need gitignored fixture bundles; 1 is real (`sc["peak_values"]["transverse"]` returns `None` where `0.0` is expected) | The real one shipped in v0.31.0. |
---
## 4. What stands between this and a real tool
Roughly in dependency order — each unblocks the ones below it.
**1. Authentication.** Everything else is gated on this. SFM has none, and
the modem IP whitelist gives zero protection because SFM *is* the whitelisted
origin. The agreed design delegates rather than builds: Terra-View becomes the
authenticated jump host (`/api/sfm/*` already inherits deny-by-default operator
auth), and the `8200:8200` publish is dropped so Terra-View is the only door.
**2. Async long operations.** POST starts a job, GET polls. Retrofitting this
after building a remote lab on top of synchronous endpoints would be far worse
than designing for it now.
**3. Confirm-guards on the remaining destructive endpoints.** Auth answers
*who*, not *did you mean it*. The webapp's erase is guarded; the other seven
destructive POSTs and `/docs` are not.
**4. The 5A page-boundary fix.** Until this lands, live event download is
unreliable on exactly the units most likely to need attention — the ones that
have been recording heavily. Wants a Blastware capture of an event spanning a
page boundary before the chunk-addressing half is trustworthy.
**5. A live Thor / Micromate client.** The device side is MiniMate-only.
Series-4 units can only be read from forwarded files, so half the fleet has no
live path at all.
**6. Test coverage that runs from a clean checkout.** 15 of 16 current
failures are missing fixture bundles. A test suite that cannot go green on a
fresh clone cannot gate anything.
**7. The SDM rename.** Cosmetic relative to the above, but the longer `sfm/`
holds the data-side code the more the tiers blur. ~30–50 files here, ~10–15 in
Terra-View, plus a Docker volume migration. Do it when the codebase is quiet.
---
## The short version
The **data side is a real tool already**. The **device side is a set of sharp
instruments** that work in the hands of the person who wrote them, with the
runbook open. The gap between those two states is mostly **auth, async, and
guardrails** — not protocol work. The protocol is the part that is actually
finished.
@@ -0,0 +1,134 @@
# Plan — "Rescue Listener": a first-class tool for the inverted rescue
**Status:** proposal, not started. Written 2026-09-17 ~01:40 local, straight
off the BE12599 incident. Open questions at the bottom need Brian's answer
before anything is built.
**Background:** `docs/runbooks/wedged_unit_recovery.md`, "Second incident —
BE12599". The manual version of this worked; this plan is about making it a
tool instead of a sequence of remembered steps at 1 AM.
---
## The problem, stated plainly
When a unit is wedged in the BE12599 mode — geophone offset above trigger,
recording back-to-back, ACH dialing constantly, device stuck repeating an AT
modem-init string and therefore **deaf to S3 over inbound** — the only channel
that works is the one the *device* opens.
Recovering it currently means:
1. Remember that `bridges/ach_server.py` exists and takes the right flags
2. Start it by hand on a box the modem can reach, with a public port forwarded
3. Go into ACEmanager and repoint the modem's Destination
4. Watch a terminal for a call-in
5. Read `rescue.json` to find out whether it worked
6. Go back into ACEmanager and repoint the modem to where it belongs
7. **Not forget step 6**, because leaving the Destination pointed at a dead
listener is worse than never having started
That is six manual steps and one landmine, executed under pressure while a
unit floods the office server.
## What the tool should be
**A "rescue listener" an operator can start for one unit, which handles
whatever that unit says when it calls in, and refuses to go away until the
operator confirms the modem has been pointed back.**
Lifecycle:
1. **Start** — operator names the target unit and starts a rescue listener.
The tool reports the exact address/port to enter in ACEmanager, plus the
actions it will take.
2. **Operator repoints the modem** to that address.
3. **Wait** — listener sits there. Live status: "waiting for call-in",
elapsed, last-seen.
4. **Act** — on call-in, run the configured rescue actions automatically,
in a safe order, each independently guarded. Report per-action outcome.
5. **Hold** — the listener **stays up** and keeps reporting, because the
modem is still pointed at it.
6. **Confirm & stop** — the operator explicitly confirms the Destination has
been restored (to `0.0.0.0`, or to the office Instantel ACH server).
Only then does the listener shut down.
Step 6 is the whole point of making this a tool. It is the step that is
easiest to skip and most expensive to skip.
## Default action set
Ordered deliberately — see "order matters" below.
| # | Action | Default | Why |
|---|---|---|---|
| 1 | **Stop monitoring** (SUB 0x97) | ✅ on | Halts recording; ends the trigger→record→dial loop at its source. Already implemented as `--stop-monitoring`. |
| 2 | **Drain events** to a diagnostics store | ⚙ configurable | The backlog is usually evidence, not garbage — see the BE12599 offset investigation. Must NOT land in the prod SFM DB. |
| 3 | **Disable ACH** (SUB 0x2C/0x7E/0x7F) | ❌ off by default | Stops the dialing — **and stops your only channel**. Opt-in, and ideally gated on step 1 having succeeded. |
| 4 | **Erase events** | ❌ off by default | Destructive. Only after a verified drain. |
### Order matters — the lesson from BE12599
Stopping monitoring *removes the call-in trigger*. ACH fires on "after event
recorded"; with recording stopped, the unit has no reason to dial again, even
though the backlog is still sitting in its memory. So a naive
"stop + disable + erase, all at once" rescue can silence the unit before
you've collected anything, leaving you with no channel and a device full of
evidence.
The tool should either sequence around this or warn loudly about it. My
instinct is: **stop monitoring immediately** (it's the bleeding), then drain
across however many call-ins it takes, and treat disable-ACH/erase as a
separate, explicit "finish" action once the operator is satisfied.
## Where it should live — open question, with a proposal
The natural tier is **SFM** (device-side, per the three-tier model in
CLAUDE.md). But the rescue listener must be reachable *from the cellular
network*, which is a deployment constraint SFM's usual profile doesn't have.
**Proposal worth considering:** run it at the office, beside the real Instantel
ACH server, on a **different port** (e.g. 12346 while Instantel holds 12345).
Then the ACEmanager change is a **port change, not an IP change** — smaller,
faster, less to get wrong, and trivially reversible. It also means the office
public IP (already stable and known) is the destination, rather than whatever
Brian's dynamic home IP happens to be that week.
The tmi-dev approach used on BE12599 worked, but required a router forward and
ran into the dynamic-IP problem in the same session.
## Open questions
1. **Where does it run?** Office beside Instantel ACH (port swap), SFM on the
NAS, or ad-hoc on tmi-dev? Affects everything else.
2. **What drives it?** Terra-View admin page (fits "operator UI"), an SFM
endpoint pair (`POST /device/rescue_listener/start` + `/stop` + `/status`),
or a CLI wrapper? A long-lived listener doesn't fit the request/response
endpoint shape well — probably needs a background task with a status poll.
3. **How does it identify the unit?** It can't know the serial until the
device calls in and the handshake reads it. Allowlist by modem IP? Accept
anything and report what showed up?
4. **Where do drained events go?** A per-incident diagnostics store
(`bridges/captures/<unit>-diag`) seems right — explicitly *not* the prod
SFM DB. Does that store need to be a first-class thing with its own
retention, or is a directory fine?
5. **How is "confirm the modem is repointed" verified?** Operator attestation
(a button), or can we actually probe it? If the listener stops seeing
call-ins that's weak evidence; if inbound to the unit starts working that's
stronger.
6. **Multi-unit?** One listener per incident, or one listener that handles any
unit that dials in? Probably the former for safety.
7. **Timeout / abandonment policy.** If nobody ever confirms, does it run
forever? Alert after N hours?
## What already exists
- `bridges/ach_server.py` — the listener itself, with `--stop-monitoring`,
`--disable-ach`, `--rescue` (added on `feat/ach-rescue-on-connect`, commit
`9f1050b`), `--clear-after-download`, `--max-events`, `--allow-ip`.
- Per-session `rescue.json` recording per-action outcomes.
- Isolated per-output-dir SQLite + waveform store, so a diagnostics capture is
already separate from prod by construction.
So the gap is not protocol work — it's lifecycle, operator surface, and the
confirmation gate. Most of the risk is in questions 1 and 2.
File diff suppressed because it is too large. Load diff
File diff suppressed because it is too large. Load diff
File diff suppressed because it is too large. Load diff
File diff suppressed because it is too large. Load diff
@@ -0,0 +1,207 @@
# SFM phase 1c — the webapp on the serial-based endpoints, plus wrong-series safeguards
> **For agentic workers:** REQUIRED SUB-SKILL: Use superpowers:subagent-driven-development (recommended) or superpowers:executing-plans to implement this plan task-by-task. Steps use checkbox (`- [ ]`) syntax for tracking.
**Goal:** The SFM standalone page (`sfm/sfm_webapp.html`) drives both series through the serial-based device endpoints. In addition, no MiniMate-only write or erase can reach a unit that has not identified itself as Series 3.
**Architecture:**
- **Server:** one helper refuses the legacy Series-3 write/erase routes unless the unit's own serial (read on the same connection) says Series 3.
- **Page:** the series routing and button rules live in a marked block of pure functions, tested through Node. The DOM wiring calls those functions and nothing else to build a `/device/` URL or decide a button's state.
**Tech Stack:** Python 3.10 / FastAPI (`sfm/server.py`), vanilla JS in one HTML file, pytest. Node 20 (`~/.local/bin/node`) runs the page-logic tests.
**Spec:** `docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md` covers "The webapp", "Scope: the parity table" rows 1–5 and 7, and "Build phases" 1c. The design agreed with Brian on 2026-10-28 is recorded in the Global Constraints below.
## Global Constraints
- Work in worktree `~/seismo-relay-parity`, on branch `feat/series4-sfm-parity`. Never commit to `main`. Check with `git branch --show-current` before every commit.
- Run tests with `/home/serversdown/seismo-relay/.venv/bin/python -m pytest -q -p no:cacheprovider`. The baseline is **16 known failures** (15 in `test_bw_ascii_report.py`, 1 in `test_event_file_io.py`). Read the failure list before committing. A `pytest | tail` exits 0.
- **Serial optional:** with a serial, the Live tabs use the serial-based endpoints: `/device/info`, `/device/monitor/status`, `/device/settings`, `/device/events`, `POST /device/events/download`, and `POST /device/monitor/start|stop` (all with `serial=`), plus `POST /device/hangup?host=&tcp_port=`. With the serial blank, every read behaves exactly as today.
- **Series comes from the unit's reply.** The badge and every series-specific control follow the `series` field of the last `/device/info` reply, and only if its `serial` equals the typed one. A typed serial alone never enables a series-specific control.
- **Write buttons:**
- Start/stop use the audited serial path for both series.
- Config write and Call-Home write are **disabled for both series**. Their tooltips read exactly "Coming in phase 5 (#46)" and "Coming in phase 4".
- Diagnostics (erase, rescue, slow drip, blind stop) is enabled only when the confirmed series is 3.
- Hang up is shown only when the confirmed series is 4.
- **Start feedback:** while a start is in flight, show "Starting — the unit runs its sensor check first (about 35 s)". The legacy 60-second `_pollMonitorConfirm` loop is not used in serial mode.
- **Results are reported as SFM returned them:** outcome, verified, state before → after, and the first 8 characters of the audit id. HTTP error `detail` strings are shown verbatim.
- **Speed (Brian):** no new request may be added to a path unless the plan says why. The server identity check reuses the serial that `connect()` already reads. On `rescue` and `POST /device/call_home` it adds exactly one SUB 0x15 read.
- No codec, store or DB change. The legacy `/device/*` routes keep their URLs and parameters (a new optional `serial` is added).
## Review Focus
1. **A typed `BE…` serial at an address that holds a Micromate.** The server must refuse every guarded route with 409 and send no write. In the page, Diagnostics stays disabled until `/device/info` answers Series 3. Pinned by Task 1 (`test_guarded_route_refuses_a_unit_that_answers_as_series4`) and Task 2 (`controls: typed serial is not confirmation`).
2. **The serial is edited after a successful identify.** The confirmation must stop counting the moment the typed serial no longer matches. Pinned by Task 2 (`controls: confirmation drops when the serial changes`).
3. **Lower-case or space-padded serials** (`" be9441 "`) are normalised the same way the server normalises them. Pinned by Task 2 (`seriesFromSerial` and `unitQuery` cases).
4. **A start that times out (504) or reads back a mismatch (409).** The page must show the server's detail and the audit id, never "started". Pinned by Task 2 (`changeSummary` cases for `failed`/`mismatch`) and Task 5 (an error-path render).
5. **A download that is already stored** (`inserted: false`) is reported as "already stored" and still opens the stored event. Pinned by Task 2 (`downloadSummary`).
---
### Task 1: Server — legacy Series-3 writes refuse a unit that isn't Series 3
**Files:**
- Modify: `sfm/server.py`:
- `device_config` (~1107), `device_events_erase` (~1427), `device_rescue` (~1763), the `device_call_home` POST (~2066);
- `device_config_project` passes `serial` through.
- Modify: `minimateplus/client.py`: add `MiniMateClient.read_serial()`.
- Test: create `tests/test_server_series3_guard.py`.
**Interfaces:**
- Produces: `MiniMateClient.read_serial(self) -> str`. Requires an open, polled session. It runs the SUB 0x15 read (`self._require_proto().read(SUB_SERIAL_NUMBER)`) and returns `_decode_serial_number(...).serial`.
- Produces: `sfm.server._require_series3(unit_serial: Optional[str], expected: Optional[str]) -> None`. It raises `HTTPException(409, detail)` when either:
- `series_for_serial(unit_serial)` is not 3 (an unknown serial counts as not 3), with detail `f"the unit at this address answers as {unit_serial!r}, not a Series-3 unit -- nothing sent"`; or
- `expected` is given and `normalise_serial(expected) != normalise_serial(unit_serial)`, with detail `f"the unit at this address is {unit_serial}, not {expected} -- nothing sent"`.
- Each guarded route gains `serial: Optional[str] = Query(None, description=_SERIAL_DOC)`. It calls the guard right after it knows the unit's serial, and before its first write:
- `device_config` and `device_events_erase`: `info = client.connect()` → `_require_series3(info.serial, serial)`;
- `device_rescue` and `device_call_home` (POST): after `client.poll()` → `_require_series3(client.read_serial(), serial)`.
- Not guarded, and each gets a one-line comment saying why: legacy `monitor/start|stop`, `stop_monitoring_blind`, `stop_monitoring_slow_drip`, `stop_monitoring_spam`. They send only `0x96`/`0x97`, which mean the same on both series (measured 2026-10-25/27), and the rescue tools must work on a unit too wedged to answer.
- [ ] **Step 1: Write the failing tests** in `tests/test_server_series3_guard.py`. Use `monkeypatch.setattr(srv, "_build_client", factory)` as `tests/test_server_device_access.py:398` does. The fake client records every call:
- `test_guarded_route_refuses_a_unit_that_answers_as_series4[route]`: parametrise over the four routes. The fake's `connect()` returns a `DeviceInfo(serial="UM20147")`, or its `read_serial()` returns `"UM20147"`. Assert `HTTPException.status_code == 409`, and that the recorded calls contain no write method (`delete_all_events`, `apply_config`, `set_call_home_config`, `stop_monitoring`).
- `test_guarded_route_refuses_a_different_series3_unit`: the unit answers `"BE9441"`, the request names `serial="BE12599"`, so the response is 409 with `"not BE12599"` in the detail.
- `test_guarded_route_proceeds_for_the_named_series3_unit`: the unit answers `"BE9441"` with `serial="be9441 "` (normalised), and the write method is called once.
- `test_unguarded_stop_routes_send_without_an_identity_read`: `stop_monitoring_blind` (it writes through a bare `TcpTransport`; stub `srv.TcpTransport`) sends its stop frames, and nothing builds a client or reads a serial.
- [ ] **Step 2: Run them.** `…pytest tests/test_server_series3_guard.py -q` → FAIL (`_require_series3` / `read_serial` don't exist).
- [ ] **Step 3: Implement** `read_serial`, `_require_series3`, the `serial` query parameter, and the four guard calls as specified.
- [ ] **Step 4: Run** the new tests plus `tests/test_server_device_access.py` → PASS. Then the full suite → only the 16 known failures.
- [ ] **Step 5: Commit** `fix(sfm): legacy Series-3 writes and erase refuse a unit that does not answer as Series 3`.
### Task 2: Page — the device-routing block (pure functions) and its Node-run tests
**Files:**
- Modify: `sfm/sfm_webapp.html`. Add one `<script>` block, delimited by the lines `/* <device-routing> */` and `/* </device-routing> */`. It must not touch `document` or `fetch`.
- Test: create `tests/test_webapp_device_routing.py`. It extracts the block, appends `module.exports = {…}`, and runs cases through `node -e` (via `subprocess`, reading JSON on stdout). Skip with a clear reason if `shutil.which("node")` is `None`.
**Interfaces (Produces, used by Tasks 3–6):**
- `seriesFromSerial(serial) -> 3 | 4 | null`: trims and upper-cases; `UM…` → 4, `BE…`/`BA…` → 3 (prefix plus at least one more character), anything else → `null`. Mirrors `sfm/device_access/series.py`.
- `unitQuery(unit) -> string`, where `unit = {serial, host, tcpPort}`:
- serial mode: `serial=<NORMALISED>&host=<h>&tcp_port=<p>`;
- blank serial: `host=<h>&tcp_port=<p>`;
- every value goes through `encodeURIComponent`.
- `deviceUrl(action, unit, params = {}) -> {method, path}`: `path` is relative, e.g. `/device/info?serial=…`. Actions:
- `info`, `status`, `settings`, `events` → GET;
- `download` (needs `params.event_id`), `start`, `stop` → POST;
- `hangup` → POST, with no `serial` (host/port only);
- legacy actions: `storage_range`, `index`, `erase`, `rescue`, `blind_stop`, `slow_drip`, `call_home_read` (GET `/device/call_home`), `call_home_write`, `config_write` (POST `/device/config`).
`settings`, `download` and `hangup` with a blank serial return `null`, since there is no legacy equivalent. Unknown actions throw.
- `confirmedSeries(unit) -> 3 | 4 | null`, where `unit.confirmed = {serial, series}` comes from the last `/device/info` reply:
- returns `unit.confirmed.series` only when the normalised typed serial equals `unit.confirmed.serial`;
- with a blank typed serial, returns `unit.confirmed.series` from a legacy identify;
- otherwise `null`.
- `controlsFor(unit) -> {startStop, hangup, diagnostics, callHomeRead, configWrite, callHomeWrite, reasons}`, all booleans except `reasons`:
- `startStop` = serial mode and `confirmedSeries ∈ {3, 4}`;
- `hangup` = `confirmedSeries === 4`;
- `diagnostics` = `confirmedSeries === 3`;
- `callHomeRead` = `confirmedSeries === 3`;
- `configWrite` = `callHomeWrite` = `false`;
- `reasons` = `{configWrite: "Coming in phase 5 (#46)", callHomeWrite: "Coming in phase 4"}`.
- `changeSummary(body) -> string`, for a ChangeResult JSON (`action, outcome, verified, state_before, state_after, audit_id, plan`):
- `dry_run` → `"<action>: dry run — would send <subs comma-joined>"`;
- `skipped` → `"<action>: already <state_before> — nothing sent"`;
- `sent` + `ok` → `"<action>: confirmed — <state_before> → <state_after> (audit <id8>)"`;
- anything else → `"<action>: <outcome>, <verified> (audit <id8>)"`.
- `downloadSummary(body) -> string`, for an EventDownload JSON:
- `inserted: false` → `"already stored — <stored_filename>"`;
- otherwise `"stored <stored_filename>, <filesize> bytes, check: <detail.check>"`.
- [ ] **Step 1: Write the failing test file.** Each case is `(function, args, expected)` and runs as `node` evaluating `JSON.stringify(fn(...args))`. Cases that must be present:
- `seriesFromSerial`: `"UM20147"`→4, `" be9441 "`→3, `"BA123"`→3, `"BE"`→null, `"XX1"`→null.
- `unitQuery`: serial mode upper-cases and trims; blank serial omits `serial=`; a host with `&` is encoded.
- `deviceUrl`: `info` with a serial → `{method:"GET", path:"/device/info?serial=BE9441&host=h&tcp_port=9034"}`; `hangup` → no `serial`; `settings` with a blank serial → `null`; `download` carries `event_id`.
- controls (named for Review Focus 1 and 2):
- **typed serial is not confirmation**: typed `BE9441` with `confirmed:null` → `diagnostics:false, startStop:false`;
- **confirmed S3**: diagnostics true, hangup false;
- **confirmed S4**: hangup true, diagnostics false, callHomeRead false;
- **confirmation drops when the serial changes**: confirmed `{serial:"BE9441",series:3}` with typed `BE9442` → all false;
- config/call-home write always false, with the exact reason strings.
- `changeSummary`: one case per outcome, including `failed` with `verified:"not_checked"` and `sent` with `verified:"mismatch"`.
- `downloadSummary`: inserted and already-stored.
- [ ] **Step 2: Run** → FAIL (no block in the page).
- [ ] **Step 3: Implement** the block in the page, just before the existing main `<script>`'s first function. Exactly the functions above, no DOM.
- [ ] **Step 4: Run** → PASS. Full suite → only the 16 known failures.
- [ ] **Step 5: Commit** `feat(webapp): the device-routing rules as pure functions, tested through Node`.
### Task 3: Page — unit bar, series badge, Device tab and status panel, Hang up
**Files:** Modify `sfm/sfm_webapp.html`. Test: extend `tests/test_webapp_device_routing.py` with the static check below.
**Interfaces:**
- Consumes: `unitQuery`, `deviceUrl`, `confirmedSeries`, `controlsFor` (Task 2).
- Produces: a page-level `currentUnit()` returning `{serial, host, tcpPort, confirmed}`. `confirmed` is held in a module variable set only by `connectUnit()` from the `/device/info` reply (`{serial: body.serial, series: body.series}`), and cleared whenever the serial or host field changes. Also `applyControls()`, which sets every series-specific control's `disabled`/`hidden` state and tooltip from `controlsFor(currentUnit())`. Tasks 4–6 call `applyControls()` after any state change.
- [ ] **Step 1: Write the failing static test.** `test_every_device_url_is_built_by_deviceUrl`: outside the device-routing block, the page source contains no `` `${api()}/device/ `` and no `'/device/` string literal. The `deviceUrl` call sites are the only way to build one.
- [ ] **Step 2: Run** → FAIL (today's page builds them by hand).
- [ ] **Step 3: Implement.**
- A **Serial** input beside host/port, `id="dev-serial"`, with placeholder `"BE…/BA… or UM… (optional)"`.
- A badge `id="series-badge"` showing `Series 3` / `Series 4` from `confirmedSeries`, or hidden.
- `connectUnit()` and `refreshMonitorStatus()` go through `deviceUrl('info'|'status', …)`. The Device tab and status panel render `UnitInfo`/`UnitStatus` fields with "—" for null (`device_time` and `event_count` are null on Series 3).
- A **Hang up** button `id="hangup-btn"`, visible only when `controlsFor().hangup`, which POSTs `deviceUrl('hangup')`.
- Convert every remaining hand-built `/device/` URL to `deviceUrl` (legacy actions included), so the static test passes. With a blank serial, behaviour is unchanged.
- [ ] **Step 4: Run** the page tests and the full suite → PASS, only the 16 known failures.
- [ ] **Step 5: Commit** `feat(webapp): name a unit by serial; series badge from the unit's own answer; Hang up for Series 4`.
### Task 4: Page — Events tab by serial
**Files:** Modify `sfm/sfm_webapp.html`.
**Interfaces:**
- Consumes: `deviceUrl('events'|'download')`, `downloadSummary` (Task 2), `currentUnit()` (Task 3), and the existing `openSidecarModal(dbEventId)` (~line 2780).
- [ ] **Step 1: Implement.** In serial mode, the Events tab lists `EventList.events`: index, `timestamp`, `record_type`, PVS and peaks, or "—". Each row has a **Download** button that POSTs `deviceUrl('download', unit, {event_id})`, shows `downloadSummary(body)` in the status bar, and then calls `openSidecarModal(body.db_event_id)` when it isn't null. HTTP errors show `detail` verbatim. With a blank serial, the existing legacy list and waveform behaviour is unchanged.
- [ ] **Step 2: Verify** the page tests and the full suite → only the 16 known failures. The bench check covers the live behaviour.
- [ ] **Step 3: Commit** `feat(webapp): list and download events by serial, for both series`.
### Task 5: Page — Start/Stop through the audited path
**Files:** Modify `sfm/sfm_webapp.html`.
**Interfaces:**
- Consumes: `deviceUrl('start'|'stop')`, `changeSummary`, `controlsFor().startStop` (Task 2).
- [ ] **Step 1: Implement.**
- In serial mode, `startMonitoring()`/`stopMonitoring()` `confirm()` with `"Start monitoring on <serial>?"` / `"Stop monitoring on <serial>?"`.
- Then POST once (never retried). While a start is in flight, show "Starting — the unit runs its sensor check first (about 35 s)".
- Show `changeSummary(body)` for any JSON body, including a 409/502 ChangeResult; show `detail` verbatim for an error without one (e.g. 504).
- Then call `refreshMonitorStatus()`.
- Buttons are enabled only by `controlsFor().startStop`.
- In serial mode the legacy `_pollMonitorConfirm` isn't called. With a blank serial, the legacy behaviour is unchanged.
- [ ] **Step 2: Verify** the page tests and the full suite → only the 16 known failures. Task 2's `changeSummary` cases cover the 409/`mismatch` and `failed` bodies; the bench check covers the live behaviour.
- [ ] **Step 3: Commit** `feat(webapp): start/stop through the audited serial path, with the honest result`.
### Task 6: Page — Config, Call Home and Diagnostics gating
**Files:** Modify `sfm/sfm_webapp.html`.
**Interfaces:**
- Consumes: `deviceUrl('settings'|'call_home_read'|…)`, `controlsFor()` (Task 2), `applyControls()` (Task 3).
- [ ] **Step 1: Implement.**
- **Config tab:** in serial mode, **Read** shows `UnitSettings` (setup name, record mode, sample rate, record time, histogram interval, geo trigger, notes, with "—" for null). **Write** is disabled for both series, with the tooltip from `reasons.configWrite`.
- **Call Home tab:** read enabled only by `callHomeRead`; for Series 4 it says "Not yet available for Series 4". Write is disabled, with `reasons.callHomeWrite`.
- **Diagnostics:** every button is enabled only by `controlsFor().diagnostics`; the erase confirmation stays as is. Diagnostics requests pass `serial` when one is typed, so the server guard (Task 1) checks it as well.
- With a blank serial, the legacy reads are unchanged, while writes and erase follow `controlsFor`. A legacy identify (blank serial) that answers as BE… confirms Series 3.
- [ ] **Step 2: Verify** the page tests and the full suite → only the 16 known failures.
- [ ] **Step 3: Commit** `feat(webapp): config and call-home writes wait for phases 4-5; Diagnostics only for a confirmed Series-3 unit`.
### Task 7: Docs
**Files:** `CLAUDE.md` (the SFM REST API section, and "Where things stand"), `docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md` (the 1c entry in Build phases).
- [ ] **Step 1:** Document:
- the legacy-route Series-3 guard (which routes, why the stop tools are exempt);
- the page's serial mode;
- the `node` requirement for `tests/test_webapp_device_routing.py`.
No CHANGELOG (feature branch).
- [ ] **Step 2: Commit** `docs: phase 1c -- the webapp by serial, and the Series-3 guard on legacy writes`.
**After Task 7 (controller, with Brian, not an implementer task):** a bench pass on BE9441 and UM20147, through the bridge or cellular:
- identify;
- status;
- settings read;
- events list and one download each;
- one audited start/stop each (Brian's go per send);
- for the Micromate, Hang up;
- Diagnostics disabled on UM20147, and enabled only after BE9441 identifies.
@@ -0,0 +1,974 @@
# SFM: Series-4 parity and a device safety layer — design
**Date:** 2026-10-20 · **Branch:** `feat/series4-sfm-parity` · **Status:** draft for review
**Decided with:** Brian, in conversation 2026-10-19/20.
## In plain terms
SFM can already *read* a Micromate almost as well as it reads a MiniMate, but
only through the Python library and bench scripts. SFM's web endpoints still
only speak Series 3. This design does three things:
1. Gives Series 4 the same everyday jobs in SFM that Series 3 has: identify a
unit, check its status, read its settings, list and download events,
start/stop monitoring, and change its settings.
2. Adds a **safety layer** every device request goes through. It makes sure a
command only reaches the unit it was meant for, logs every change, and
checks every change by reading the unit back.
3. Lets SFM **stay on the line** with a Micromate. It calls up once, confirms
the serial, and keeps the connection open for later commands instead of
reconnecting each time.
**The guiding principle (Brian): talking to a Series 3 unit and talking to a
Series 4 unit is the same for the user.** It is the same screens, the same
endpoints, the same way of naming a unit, and the same shape of answer. The
only visible difference is the serial (`UM…` vs `BE…`) and the settings each
model has. The differences live underneath, in one adapter per series.
It does **not** cover the emergency tools (runaway-unit stops, rescue, erase),
the call-home receiver, or anything async. Those come later, as features
shared by both series.
**Production reach, stated honestly:** while THOR is set to stay connected to
production Micromates, a modem's single connection is taken. SFM can't reach
those units until THOR lets go or SFM takes over call-home. In this phase,
Series-4 SFM is for the bench and for units THOR is not holding.
---
## Decisions
| decision | why | who |
|---|---|---|
| **One user experience for both series** | the user's method is identical; only the serial prefix and each model's settings differ; adapters absorb the rest | Brian |
| Match **jobs**, not endpoints | some Series-3 endpoints only exist to work around Series-3 quirks | agreed |
| **No Series-4 emergency tools** yet (runaway stop, rescue, erase) | Micromates rarely need them | Brian |
| The series comes from the **serial prefix**: `UM` = Micromate, `BE` = MiniMate Plus, `BA` = Blastmate | the prefixes are definitive, so there is no probing | Brian |
| Before any **write**, confirm the unit that answered is the one named | SFM addresses units by IP; a moved modem or stale IP means a different unit answers | agreed |
| **Synchronous** endpoints for now; async later, for both series together | parity first, then shared features | agreed |
| **No library of setup files on the PC** (unlike THOR). The unit's own settings are the truth: SFM reads them from the unit, and verifies every push by reading the unit back | THOR keeps one copy of each setup on the PC and another on the unit, linked only by file name. Nothing checks the contents match, so the PC's `test2` and the unit's `test2` can say different things | Brian |
| **Sessions for Series 4 now; Series 3 only after a bench test** | THOR holds Micromate lines daily without harm; a MiniMate's hangup/DCD behaviour is untested | Brian |
| Audit log in **SFM's database** (new table) | Terra-View can show it; it fits the existing `CREATE TABLE IF NOT EXISTS` pattern | proposed |
---
## Scope: the parity table
Rows 8 and 11 of the original inventory (runaway stops, rescue/erase) are out
of scope by decision. Row 6 (monitor log) moved to the parking lot: it is its
own piece of work, together with call-in monitor-log ingest.
| # | job | Series 3 in SFM today | Series 4: protocol status | Series 4 in this phase |
|---|---|---|---|---|
| 1 | Identify a unit | `/device/info` (walks the whole chain, slow) | implemented: `connect()` | dispatch to the Micromate client |
| 2 | Quick status (monitoring, battery, memory, clock) | `monitor/status`, `storage_range`, `events/index` | implemented: `get_state()`; the `0x06` event count is decoded only in the bench tool | same endpoints; move the count decode into the client |
| 3 | Read settings | compliance in `/device/info`; `GET /device/call_home` | `get_setup()` implemented and verified on hardware; call-home: enable + dial string observed, rest unmapped | setup in full; call-home returns enable + dial string + raw |
| 4 | List events | `/device/events` (downloads every event to list them) | implemented, and cheap: the chain walk returns sizes | the same event-list shape as Series 3, each event carrying an `event_id` |
| 5 | Download an event | `/event/{i}`, `/waveform`, `/blastware_file` | implemented: streams the `.IDFW`/`.IDFH` itself, with a decode self-check | the same download and save-to-DB actions as Series 3. Underneath, Series 4 saves through `/db/import/idf_file` |
| 7 | Start / stop monitoring | `monitor/start`, `monitor/stop` | mapped, identical to Series 3 (`0x96`/`0x97`, acks `0x69`/`0x68`); never sent | **first write.** Verify with `0x49` state |
| 9 | Change call-home settings | `POST /device/call_home` | write mapped (`0x2C` → `0x7E`/`0x7F`, same as Series 3); field map mostly unknown | enable/disable only; the rest waits for the THOR round |
| 10 | Change recording settings | `POST /device/config` | sequence mapped (`0xDA` → `0x68/73` → `0x82/83` → `0x71/72`); no encoder | read-modify-write, stop → push → restart, verify with `get_setup()` |
---
## Architecture
### One door for every device request
A new module, `sfm/device_access.py`, sits between the `/device/*` handlers and
the two device libraries. No handler opens a transport or picks a library
itself any more.
```
/device/* handler
│ (serial, address, action, tier)
▼
device_access ── series from serial prefix ── session / per-unit lock
│ │ │
│ ▼ ▼
│ minimateplus (S3) or micromate (S4) audit table
▼
read-back verification (changes only)
```
- **Naming a unit is the same for both: `serial` + address.** The prefix picks
the adapter: `UM` → Series 4 (`micromate`); `BE` or `BA` → Series 3
(`minimateplus`); any other prefix → 422. A request with no `serial` is
treated as Series 3. That is a **legacy path** kept only so existing scripts
keep working; the webapp and every new caller always send `serial`.
- **One contract.** Same `/device/*` paths, same request parameters, and
**the same response models for both series**:
- `UnitInfo`, `UnitStatus`, `UnitSettings`, `EventRef`, `ChangeResult`
- Anything only one series has goes under a `detail` object inside the same
model, never as a different top-level shape. `"series": 3 | 4` is
informational.
- **Events have one identity.** An opaque `event_id` string from the event
list, passed back to download it. Underneath it is Series 3's position or
Series 4's device key, plus the serial; the user never handles either.
- **Not-yet-supported is uniform.** If one series can't do something yet,
the endpoint still exists and answers **501 "not supported for Series N
yet"**. It is never a missing route or a different call.
- **Work separate from HTTP.** Each operation is a plain function taking the
session. The handler is a thin wrapper, so making an operation an async job
later means changing the wrapper, not the operation.
### Adapters
Each series implements the same operation set behind `device_access`:
| operation | Series 3 adapter | Series 4 adapter |
|---|---|---|
| `identify` | STARTUP + serial + config | `connect()` |
| `status` | `0x1C` (+ `0x06`) | `get_state()` + `0x06` count |
| `read_settings` | `0x1A` compliance decode | `get_setup()` |
| `list_events` | today's walk | chain walk (cheap) |
| `download_event` | 5A → Blastware file | 5A → `.IDFW`/`.IDFH` |
| `start` / `stop` | `0x96` / `0x97` (exists) | `0x96` / `0x97` (new) |
| `read_call_home` / `set_call_home_enabled` | exists | `0x2C` / `0x7E`+`0x7F` |
| `push_settings` | `/device/config` path (exists) | setup push (new) |
| `call_up` / `hang_up` | connect-per-request underneath, until the bench test | held session |
Each adapter maps its native data into the shared models. `UnitSettings` keeps
the fields both series have under the same names and units: record mode,
sample rate, record time, histogram interval, trigger levels, the notes as
label → value. Model-specific fields go under `detail`.
**Requests that include `serial` get the shared models; requests without it
keep today's Series-3 shapes, unchanged.** Nothing breaks in between: the
webapp moves to `serial` in phase 1c, and the old path retires after that and
after `watch_unit.sh` moves. Terra-View does not call `/device/*`. The
emergency endpoints (`stop_monitoring_*`, `rescue`, `events/erase`) are not
touched and stay Series-3 only; a `UM` serial gets 501.
### The webapp
The same screens for both series. You name a unit by serial + address (today
it takes host/port only), and the series shows as a badge, nothing more. Read
panels for both series land in phase 1; each write button appears for Series 4
in the phase that adds that write.
### The safety layer
**Tiers.** Every operation declares one:
| tier | examples | what the layer does |
|---|---|---|
| read | info, status, setup, events, download | runs; no identity check |
| change | start/stop, call-home, setup push | identity check → audit → send → **read back** → audit the result |
| destructive | delete, erase (none in this phase) | everything above + the caller must send the unit's serial as `confirm` |
**Identity check (changes only).** Before the first change in a connection,
compare the serial the unit reports with the one requested; on a mismatch,
refuse (409) and send nothing. Series 4 already reads the serial in
`connect()`. A Series-3 change adds one serial read (`SUB 0x15`), about one
round trip.
**Opcode guard.** A send-side check that refuses known cross-series
collisions. It starts with **`0xA2`**, which is CONFIRM ERASE on Series 3 and
"end call-home" on Series 4. This phase never sends `0xA2`; the guard makes
that impossible by accident. The table of colliding opcodes lives in one
place.
**One connection per unit.** A per-unit lock keyed by address
(`tcp:host:port` / `serial:port`). A request for a busy unit waits up to
**20 s** (configurable; under Terra-View's 60 s proxy timeout), then gets
**423 "unit busy"** instead of opening a second connection. This applies to Series 3 as well. The webapp's Diagnostics
refresh currently fires three device requests at once against a modem that
allows one; under the lock they queue.
**Read-back verification.** A zero-data ack has never been proof that a write
applied. Every change is followed by a read:
- start/stop → `0x49` state: start expects `0x02`, stop expects `0x00`. Record
the value either way; `0x03` is the in-call-home state
- call-home → re-read `0x2C` and compare the edited bytes
- setup push → `get_setup()` and compare every field that was set
A mismatch is reported as a failed change (and audited as one), even if the
ack was clean.
**Errors that say what happened.** Distinct responses for:
- 503: couldn't connect
- 504: connected but the unit didn't answer
- 423: unit busy
- 409: wrong unit
- 422: bad input
- 502: the reply was malformed
Today 502 covers both of the first two.
**Audit table.** New table `device_commands`, created on startup like the
others. It is additive, but still a schema change, so the changelog says so.
One row per change attempt:
| column | content |
|---|---|
| `ts`, `serial`, `series`, `address` | who and where |
| `action`, `tier` | e.g. `monitor_stop`, `change` |
| `request` | parameters, plus hex of what was sent |
| `ack` | reply summary |
| `verified` | read-back result: `ok` / `mismatch` / `not_checked` |
| `outcome`, `error` | final result |
| `caller` | best-effort origin (`webapp`, `terra-view`, `script`) |
Reads are not audited.
### Sessions
1. **Call up.** Connect, `connect()` (POLL / SERIAL / STATE), identity check
against the requested serial.
2. **On the line.** Requests for that unit run in turn on the same connection,
behind the per-unit lock.
3. **Keep-alive.** A POLL every 60 s while idle. The ACEmanager TCP idle
timeout is 2 min.
4. **Hang up.** On `POST /device/hangup`, after 5 idle minutes, or on any
transport error. A reconnect is a new session with a new identity check.
5. **Ring safety.** If `RADIO RING` arrives on an SFM session, log it and hang
up **immediately**. Until SFM is the call-home destination, the unit's
retry should reach THOR. 🔶 *Inferred:* the unit retries; its `0x2C`
retries field reads 3.
**Call up and hang up are the same for both series.** Underneath, the
Series-3 adapter keeps today's connect-per-request behaviour until the bench
test under *Testing*; the user sees the same actions either way.
### Series-4 write path
**Encoder.** Extend `micromate/framing.py`:
- a request builder that carries a data section
- the same escape set `{02,03,04,10}`, applied to data, params and checksum
- plain SUM8 of the destuffed payload (*not* Series 3's write format)
Rules: `micromate_protocol_reference.md` → *The escape set — exactly four bytes*,
*Checksum — plain SUM8 of the de-stuffed payload*, *Write-frame destuffing*.
**Dry run.** Every Series-4 write accepts `dry_run=true`. It returns the exact
frames it would send and sends nothing. The first live send of each write is
reviewed this way first.
**Per operation:**
| operation | frames | verify | open questions it settles |
|---|---|---|---|
| start / stop | `0x96` / `0x97`, offset `0xFFFF`, zero params | `0x49` | the ack when already in that state |
| call-home enable/disable | read `0x2C` → `0x7E` (126 B content, offset `0x007E`) → `0x7F` | re-read `0x2C` | none new; bit 0 of `write[5]` |
| setup push | read `0x08`, `0x2E`, `0x1A` → `0xDA` (name) → `0x68`/`0x73` → `0x82`/`0x83` → `0x71`/`0x72` | `get_setup()` | the offset rule; whether `0x68`/`0x82` are needed |
**Setup push, details:**
- Read-modify-write of **all three** blocks, as THOR appears to do.
🔶 *Inferred from two captures:* `0x68` = the preferences content with
`[0:3]` zeroed; `0x82` = the `0x2E` content with `[0:3]` and the CRC slot
zeroed; `0x71` = the `0x1A` content `[0:2090]` with the length echo zeroed.
- Offsets come from THOR's observed constants. 🔶 The hypothesis "offset =
the read block's length + 2" fits all four, but each has been seen at one
size only.
- The edited fields come from `MicromateSetup` and are written back at the
offsets `setup_block.py` already uses. Only fields graded **measured** may
be edited.
- Sequence: stop monitoring (if running) → push → restart (if it was running)
→ verify. THOR's "must be idle" is policy, not the device, but stopping
first removes a variable from the first live write.
- ⚠ **Edit-buffer hazard.** `0x1A` reads the keypad's unsaved edits, so a
read-modify-write taken while someone is in the menu would commit them.
This can't be detected from the wire; it is documented in the endpoint and
audited.
- **Target file:** the active setup, overwritten in place, by default. A
named target is allowed, but overwriting a *non-active* setup or
`factory.MMB` is untested, so it is refused in this phase.
---
## Testing
**Offline (CI-capable):**
- **Frame reproduction.** The new encoder must reproduce THOR's captured write
frames byte for byte: `0x96`/`0x97`, `0x7E`/`0x7F`, and the full setup push,
from the 9-24 / 9-25 / 10-14 captures. This is the same method that proved
the reads (218/218). The needed frames are copied into force-added fixtures,
since `bridges/captures/` is gitignored.
- **Safety layer on fakes:**
- series by prefix
- identity mismatch → 409, nothing sent
- `0xA2` refused
- lock → 423
- read-back mismatch → failed change
- audit row written for every change attempt
- RADIO RING → session ends
- **Endpoints** through FastAPI's `TestClient` against the scripted transport
already used in `tests/test_micromate_client.py`.
- **Contract tests.** The same test, run against both adapters with fakes,
asserts that each job returns the same model with the same field names and
units. A field present for one series and absent for the other is a test
failure unless it lives under `detail`. This is the test that keeps the
guiding principle true as the code grows.
**Bench (UM20147, with Brian):** each write's first live send follows the same
protocol:
1. Dry run.
2. Review the frames.
3. Send once, with a capture running.
4. Read back.
5. Write the result into the reference.
Order: stop/start → call-home off/on → setup push of one field → setup push of
several fields.
**Series-3 session test (before Series-3 sessions are built):** hold a call-up
session open to a MiniMate that is monitoring, for several minutes. Record:
- does it keep monitoring (does an event still record)?
- after hangup, is it monitoring?
- does it behave differently on an RV55 with the DCD issue?
---
## Build phases
Each safety piece arrives with its first real use, so nothing sits untested.
1. **One contract, reads only.** `device_access.py`, the two adapters, the
shared models, series selection, the per-unit lock, the error mapping, and
sessions with ring safety. Rows 1–5 for **both** series through the same
endpoints. **No writes.** Split into three plans:
- 1a. The foundation plus identify / status / settings for both series.
- 1b. Event list and download for both series (rows 4–5). Decided with
Brian 2026-10-21:
- **MiniMate events are listed from their headers** (`0A` + `1E` arm +
`0C` + `1F` browse, no `5A`) instead of downloading every event to list
it, and one event downloads without the ones before it. It reuses the
bypass `skip_waveform_for_events` already takes, so no new command
reaches the wire. The legacy serial-less `/device/events` keeps its
full-download walk. 🔶 Unproven on a unit: **a MiniMate bench check is
owed before this branch merges.** Its scope (final review,
2026-10-21):
- a list of three or more events, confirming `1F(browse)` advances
after a `1E(arm)` without `1F(arm)`;
- a non-first event;
- a histogram-mode event, capturing its `0C` (which would let Series
3's `record_type`, `null` today, be decoded);
- an event past 64 KB, expecting the named 502;
- a stale-id download, confirming no `5A` goes out;
- a download of an event Blastware's call-home already delivered (one
waveform, one histogram), expecting `already_stored`. This is the
only way to measure that Series 3's (serial, timestamp) agrees
between the unit's `0C` and the watcher's import; if it does not,
a download silently stores a duplicate row (never a downgrade).
Measured for Series 4: 1,016/1,016 watcher imports found by the
lookup (2026-10-21).
- a dropped reply, via `bridges/mm_link.py`-style fault injection.
**First run, 2026-10-25, on BE9441** (S338.17, mic disabled, serial
cable). It found four bugs; all four are fixed with tests built on its
logged bytes (`a8cc516`, `352f694`, `75d79ec`, `36f4e5d`, `d73a27d`).
- ✅ **List: 20 events,** in order, with distinct keys. The header walk
advances.
- ❌→✅ **A non-first event:** stored 2 bytes short, so it decoded
truncated. The body builder assumed metadata pages in every stream.
Fixed. A Series-3 download is now checked against the unit's own
peaks, so this class of bug is refused rather than stored.
- ❌→✅ **The first request after the port opens failed.** The unit
boots on connect, and its banner came ~3 s after the POLL had already
gone out. Fixed: startup waits for a unit it sees booting.
- ❌→✅ **A reboot mid-download stored a partial event as a success.**
This was the dropped reply, occurring live. Fixed: a one-event
download is whole or it is an error.
**Re-run, 2026-10-26, same unit, fixes in place:**
- ✅ Identify: the unit booted on connect and SFM waited for it.
- ✅ Events 0, 1, 3, 4 and 10 downloaded whole and **verified**.
Events 0 and 1 are byte-identical to their fixture checksums.
- ❌→✅ **Event 3 failed again at chunk `0x7D06`, the same address
both days.** The request's checksum was a bare `0x02`, which the
unit reads as STX; it never answered, and rebooted ~11 s later. That
was the "mid-download reboot". Escaped (`10 02`) it answered at once
(`d56dde7`).
- ✅ **The 64 KB page boundary:** events 2 and 19 cross it, and are now
refused by name (502) before any chunk (`bf9e32c`). The page bug
itself remains.
- ✅ **Stale id:** 409 after a header walk, with no 5A sent.
- ✅ **A repeat download:** `already_stored`, nothing written.
- ✅ **Against Blastware's own files** (Brian's downloads of all 20
events): SFM's events 0, 1, 3, 4 and 10 are **byte-identical** to
Blastware's. Importing Blastware's files first through the watcher
route makes SFM's downloads return `already_stored`, with no
duplicate rows.
- ✅ **The 64 KB page bug is FIXED (`887e75d`).** A recording of
Blastware downloading all 8 events (4 crossing a page) showed every
request escapes 02/03/04/10, and that a 5A request is an ordinary one
carrying a length and a 32-bit linear address. Live on BE9441, all 8
events downloaded whole and verified, the 4 crossings included.
Review follow-ups: the chunk cap is sized from STRT (a caller's 128
cut events past ~66 KB short, e.g. large histograms), a misread STRT
is refused, TERM only for a true tail.
- ✅ **A histogram event, over 66 KB (2026-10-26 evening).** BE9441,
2 s intervals, 4,096 sps, 3,398 intervals, 71,106 B: 139 requests and
two 64 KB crossings. SFM's download (by serial, through the bridge)
is byte-identical to Blastware's file, as is the 59 KB waveform. The
mic-off histogram was refused ("decodes as neither") until #47 (on dev)
reaches this branch. Fixture `minimate-bench-10-26-26-histogram/`.
- ✅ **Stop through the new path (2026-10-26 18:53).** Brian's go. The
flag read 0x0B (histogram monitoring); SFM had shown "not monitoring"
and refused the state as unknown until `d990466` (0x0B measured; the
status also misread an escaped 04 in free memory). The stop frame was
Blastware's bytes; it was acked 0x68 and read back idle, audit
`c9c17128`. No call-home attempt after it.
- ✅ **Start through the new path (2026-10-27 00:12).** Brian's go;
idle → monitoring, verified, audit `cb540970`, 36.7 s; the stop that
followed verified too (`2618c81a`). Two earlier starts were acked and
the unit recorded, but their read-backs went unanswered: a bare 0x1C
(`9886422` added the wake), then a single wake sent 2 s in, inside the
~30 s sensor check (`ca5c401`: a start's first read waits 30 s, then the
wake repeats every 5 s up to 60 s). A third was cancelled at the
keypad mid sensor check; SFM read it back honestly as a mismatch
("unit reads idle", 30 reads), audit `b019ae6d`.
- 🔶 **A stop starts a call-home when auto-call-home is on** (Brian,
2026-10-27): stopping by command or keypad makes the unit call home and
upload its events + MLG, which can take minutes. UM20147's `0x01` for
~18 s after a stop (10-25) fits; BE9441 never called home (ACH
presumably off). For SFM: after a stop the read-back may meet a
call-home state, a ring, or silence, and on cellular the unit contends
for the modem's one TCP session SFM may be holding. **Series 3's 0x1C
value during a call-home is unmeasured** -- the change path would
refuse it as unknown. To measure: a MiniMate stop with ACH on, through
the bridge.
- ⚠ **MiniMate config push (#46): framing fixed (`b5037b0`), NOT
usable yet.** Review 2026-10-27, measured on recorded reads: (C1)
`read_compliance_config` keeps three escape bytes from its reply
headers, so every real config is refused -- now before any frame is
sent (`push_config_raw` checks all four blocks first); (C2) fixing that
read alone lets the encoder write some fields to the wrong bytes while
the image still passes the N+2 guard (e.g. 4,096 sps written as 4,112).
The rework: read the compliance block logically (reply page bytes +
data, unescaped), encode at the measured logical offsets (mode [5],
rate [6:8], interval [8:10], record time [18:22], trigger Tran+30,
alarm Tran+38) -- with #48 --, diff-check that only the requested
fields changed, pin N per SUB, refuse unless 0x1C reads idle, give
`POST /device/config` the start/stop safeguards, and test
`apply_config` from recorded replies. Review findings I2-I4, M1-M4
are in the #46 thread.
- Still owed:
- **before merging to dev, align `persist_download`'s already-stored
check with what v0.32.0 shipped** (dev `04acb99`; restamp `5737168`,
then `3a6df9d` fix/waveform-time-from-record). A Series-3 waveform's
time comes from the unit's **embedded event record** in the 5A stream
(`00 28 05 00 ?? ?? fe 80 [trigger][stop]`,
`event_file_io._embedded_event_record`), which SFM's own downloads
carry too; the filename is a cross-check only, never a fallback.
`Event.timestamp_source` says which ("event_record" / "report" /
"footer" / "estimate"). Mirror the DB rules: match by stored file
as well as (serial, timestamp) (`SeismoDb._restamp_by_file`), and an
**"estimate" time never matches, moves or duplicates a row**
(`SeismoDb._estimate_guard`). Take the semantics from the merged
code. Expect a trivial conflict at the top of the Series-III
reference's changelog table (dev added 2026-10-26 (5)).
- a dropped reply via fault injection. It happened for real on
10-25, but that was our checksum bug, not a lossy link;
- ~~whether standard (non-5A) requests need the same checksum
escape~~: settled 2026-10-26. Every request escapes 02/03/04/10
(748/748 Blastware requests), and `build_bw_frame` now does.
- **Download = fetch, check, store** in SFM's database, the same as
Series 3's `blastware_file` route, and returns the stored row's id. The
file and waveform are then served by the existing `/db/events/{id}/…`
routes. The database matches on (serial, timestamp), so storing an
event already stored, including one THOR's watcher forwarded, ~~refreshes
the row instead of duplicating it~~. **Changed by the final review
(2026-10-21):** it returns the existing row and writes nothing
(`inserted: false`, `detail.already_stored: true`). Never merge: the
watcher's copy, with its paired report, is the richer one, and a
refresh measurably downgraded it (PVS, project strings and ZC
frequencies went NULL).
- **`event_id` = `<serial>:<key>:<YYYYmmddHHMMSS>`.** Both series reuse
keys (after an erase, and across Micromates), so a download whose key
now holds a different event fails with 409 instead of fetching it.
- **Micromate downloads walk to the event first** (the only order captured
from THOR), with THOR's 1,024-byte chunks.
- 1c. **The webapp:** serial + address, and the same read panels for both
series.
- ~~**HARD PREREQUISITE:** before any poller or webapp sends `serial`, add a
per-address cool-down after a RADIO RING~~ -- **changed 2026-10-23
(Brian): test first, build only if needed.** Before any poller or webapp
sends `serial`, run the ring-path bench test under *Open questions this
design leaves for the bench*. If Run B shows a poller keeps the call
from reaching THOR, add the per-address cool-down: call-ups to that
address answer 503 + `Retry-After` until it expires, and
`POST /device/hangup` clears it, with its length taken from Run A. If
THOR gets the call anyway, no cool-down is needed.
- **Built 2026-10-29** (plan `docs/superpowers/plans/2026-10-28-sfm-phase1c-webapp.md`).
A Serial field beside host/port; with one, identify, status, settings
(read-only), events (a Download per row) and audited start/stop go
through the serial routes for both series, and Hang up shows for a
Series 4. Series-specific controls follow the unit's own `/device/info`
answer and drop when the serial, host or port is edited; config and
call-home writes are off for both series until phases 5 and 4;
Diagnostics needs a confirmed Series 3. Without a serial the page reads
as before. The rules are pure functions in one marked block, tested
through Node (`tests/test_webapp_device_routing.py`).
**Server side, the same phase:** the legacy Series-3 writes and erase
(`/device/config`, `/config/project`, `/events/erase`, `/rescue`,
`POST /device/call_home`) refuse 409 before any write unless the unit
answers as Series 3 (and as the named unit, given `serial=`). The stop
tools stay exempt: 0x96/0x97 mean the same on both series.
- **Bench pass 2026-10-29 (BE9441 and UM20147, each on its own modem):**
identify, status, settings, list, one download, start and stop through the
page on both series. Sixteen findings, listed under *Left open by the 1c
bench* below.
- **Ring path, 2026-10-29 (measured; details under *Open questions ... for
the bench*):** with THOR's watchdog off, a call-home **reaches THOR** when
nobody holds the line (Run 0), and **is lost** when SFM holds it (Run A):
the unit takes SFM's connection for the call, sits in "call home data
transfer", times out, goes idle and does not retry. With THOR polling, SFM
cannot reach the unit at all and does not disturb THOR (A2, step 1).
The 5-minute Micromate line hold makes SFM a call-home sink whenever THOR
is not holding the line; a cool-down alone would not help (the unit does
not retry).
✅ **Decided 2026-10-29 (Brian): keep the hold as it is for now** -- not
expected to be a problem in practice -- and the long-term fix is **SFM
handling auto call-ins itself** (the ADR 0003 call-in server). This
settles the 1c ring-path merge gate; Run B (a poller in THOR's reconnect
gap) stays open, not blocking.
- Of the items parked for 1c below: **CORS ordering** does not bite the
page, which SFM serves itself (same origin); the **Series-4 mic** is not
shown (the event list shows geophone peaks only). The rest are server-side
and stay open.
2. **Encoder + opcode guard + dry run + frame-reproduction tests.** Still
nothing sent.
(2026-10-22) "Dry run" in this phase means the **write plan**: the exact
frames, in order, with their expected acks, built from the unit's own reads
(`micromate.writes`), plus a bench tool that prints one from a live unit's
reads (`bridges/mm_dry_run.py`). Each write endpoint's `dry_run=true`
arrives with that write in phases 3-5 and returns the plan. The opcode
guard is a **send-side gate** in `MicromateProtocol._send`: every write SUB
is refused unless the connection was built with it allowed (none is, in
this phase), and `0xA2` is refused always.
3. **Start/stop monitoring** (row 7): the first live write, at the bench.
Brings the identity check, the audit table and the read-back framework.
- **Preconditions from the phase-2 final review (2026-10-22):**
- **Write permission is scoped to one call, not a connection.**
`MicromateProtocol.execute(plan)` is the only write path: it transmits
exactly that plan's frames and nothing else. The connection's own
`allowed_writes` stays empty -- a held `Series4Session` lives for
minutes, and a grant made at call-up would outlive the request.
- **A code-reviewed ceiling** in `micromate/opcodes.py` lists the write
SUBs any code may transmit: `{0x96, 0x97}` in this phase, each later
phase adding its own. Delete (`0xA8`/`0xAA`), raw file writes
(`0x8D`/`0x8E` -- they could reach the modem settings) and `0xA2` are
enabled only by a spec change.
- **A write is never retried.** `DeviceAccess._dispatch`'s retry-once
refuses change-tier operations structurally, not by comment.
- **Build the plan inside the unit lock, on the same line, right before
sending.** A plan returned by an earlier dry run is never transmitted;
optionally the dry run returns a digest the live call must echo.
- **Read state first** (`0x49` for start/stop, `0x2C` for call-home) and
decide on purpose whether "already in that state" is skipped or is the
experiment.
- **Refuse writes unless this connection's responses carried Micromate
flags** (0xC5/0x03), alongside the serial identity check.
4. **Call-home enable/disable** (row 9).
5. **Setup push** (row 10): one field first, then several.
Each phase is its own implementation plan. **All phases land on
`feat/series4-sfm-parity` and merge to `dev` once, when everything here is
implemented** (Brian, 2026-10-21) — not one merge per phase.
---
## Out of scope (this phase)
- Series-4 emergency tools: runaway stops, rescue, per-event delete, erase.
(Erase-all is also unmapped.)
- Async jobs; auth (Terra-View as jump host); the call-home receiver. These
are shared features for later.
- Scheduler read/write/enable; clock set; remote sensor check; restart;
firmware.
- Series-3 sessions, pending the bench test.
- Mapping the rest of `0x2C` (the THOR round).
## Fix list (found 2026-10-19, separate small changes)
- `bridges/ach_server.py:524`: `seen_keys` is undefined. Series-3 call-home
monitor-log collection has failed every session since `9afa348`
(2026-05-07).
- `bridges/mm_ach_server.py:262`: `_cstring`/`_content` aren't imported, so
the ring-answer path would raise `NameError`. From `8f67608` (2026-10-14).
- Series-3 `5A` 64 KB page-boundary bug (known; surfaces as HTTP 500).
- `POST /device/config` writes a fixed 29-byte `0x82` blob from one 3-11-26
capture, whatever the unit's trigger settings.
- `/device/events` runs a full 5A download per event just to list headers.
- `0x08` is named `read_event_index` in `micromate/`; it is the preferences
block.
## Left open by the phase 1a review (2026-10-21)
Minor findings from the whole-branch review, parked here so they outlive the
plan's scratch ledger. None blocks 1a; the phase each one matters to is named.
- **CORS ordering (1c, if a browser calls SFM directly).** The `/device` guard
middleware is registered after CORS, so it sits outside it: its 409/501
responses carry no `access-control-allow-origin`, and an OPTIONS preflight to
a guarded URL gets the guard's refusal instead of CORS's 200. Register CORS
last, or let OPTIONS through. Terra-View proxies server-side and is not
affected.
- **Legacy handlers take no unit lock (1c / phase 3).** The guard checks for a
held line and then lets the legacy handler run unlocked; a legacy request
admitted just before a Series-4 call-up at the same address can overlap it.
- **Address keys are not normalised.** `tcp:<host>:<port>` is the raw string:
a hostname vs an IP, or `/dev/serial/by-id/...` vs `/dev/ttyACM0`, gets two
locks for one link.
- **A serial-less request to an UNHELD Micromate still runs Series-3 bytes.**
The guard only knows about lines SFM holds. ~~This is the phase-2 opcode
guard's job.~~
**Measured by the phase-2 final review (2026-10-22):** the phase-2 gate
covers `micromate/` only and cannot see this traffic. Only the three blind
stop tools (`/device/stop_monitoring_blind`, `_slow_drip`, `_spam`) send a
write before any parsed reply. Every other legacy write route needs a
parsed `0xA4` POLL reply, and `S3FrameParser` never yields one from
Micromate bytes (364 real responses → 29 spurious frames, none `0xA4`). So
erase, config and call-home writes cannot reach a Micromate. Worst case
(inferred): an unheld Micromate at the address stops monitoring, via the
Series-3 `0x97` at offset 0x0000, never sent to one. The hazard is identity
(a moved modem or a stale IP), not series. **Brian's decision** (the legacy
routes are bound by 'behave exactly as today'): accept until the legacy path
retires after 1c, then require `serial` on the blind tools; or, as an
interim, refuse a blind tool when SFM's DB last saw a `UM` serial at that
host.
- **`tcp_port` coercion mismatch.** The guard parses with `int()`, pydantic
coerces more loosely (`"9034.0"`), so such a request passes the guard
unchecked. Parse with pydantic's own int coercion, or fail closed.
- **Test gaps.** The middleware wrapper itself is untested (a raw ASGI call
works without httpx); the contract test compares field names of one shared
dataclass, which cannot fail, and does not enforce "a field absent for one
series lives under `detail`".
- **`_ensure_reaper` race.** Two first Series-4 requests at once can start two
reaper threads; harmless because `try_hold` keeps them off each other's units.
- **Held serial lines share `/dev/ttyACM0` silently.** pyserial's open is not
exclusive, so a bench script beside a held line interleaves bytes with the
keep-alive; it looks like a dead unit. Open with `exclusive=True`, or don't
hold serial links.
## Left open by the phase 1b review (2026-10-21)
Parked from the whole-branch review of 1b; none blocks it. The phase each
matters to is named.
- **Retry re-runs a whole download (1c).** The retry-once on a held-line timeout re-runs the full download, roughly doubling time-to-error; narrow it to failures before the first reply.
- **`last_used` after a kept-line error (1c).** It is not refreshed when an op's verdict (404/409) keeps the line, so the idle hang-up comes early.
- **`verified: null` is ambiguous (1c).** It means both "a histogram" (no check exists) and "a waveform whose check could not run".
- **Mic naming and the Series-4 mic decode (1c).** `detail.mic_psi` on Series 3, `detail.mic` on Series 4; Series 4's `0x0C` mic decodes as a denormal (~5e-39) — fix the decode before 1c shows it.
- **500 detail leaks paths (1c, before SFM is reachable beyond Terra-View).** The download handler's 500 detail includes raw exception text, filesystem paths included.
- **Serial as a directory name (1c).** The serial is never checked against `[A-Z0-9]+` before it names a store directory; only the unit can choose it, but the check is cheap.
- **No server-level RADIO RING mid-download test (1c).** Covered structurally (DeviceAccess-level test + the ring transport), not through the handler.
- **Series-3 stored `record_type` (MiniMate bench check).** Rows SFM stores for Series 3 still say "Waveform" for histograms — pre-existing, the same as the legacy `blastware_file` route; fix it with the `0C` decode.
- **A fresh Series-4 download's gaps (1c).** No `sample_rate` is stored, and the sidecar has no vector sum; the DB row has the unit's PVS (overlaid from `0x0C`).
- **Orphan files (SDM).** An event file in the store with no DB row is still overwritten by a download.
## Left open by the 1c bench (2026-10-29)
From the page bench on BE9441 (MiniMate, modem `63.43.212.233`) and UM20147
(Micromate, RX55 `63.45.161.30`). Numbers as given at the bench. Fixes wait for
a short plan; #14 waits for the line-hold decision above.
1. **S3 settings decode reads before escapes are removed** -- BE9441 showed 0 sps
and a 68.3-min interval (true: Histogram, 4096 sps, 2 s, per the 10-26 fixture
README); while monitoring the `1A` anchor is not found at all. Old bug, the
same family as #46's C1. Fix: decode after unescaping; this reply is the
fixture.
2. **A 1.7 KB mic-off histogram is refused** -- this branch lacks #47/#49 (`dev`
decodes `K441LTOK.QZ0`, this branch does not). Bring them over before merge.
3. ✅ The 71 KB histogram crossing two 64 KB pages downloaded over the modem
byte-identical to Blastware's (`f10f39a8…`).
4. List vector sum 0 / −0 for three events whose peaks reach 1.08 in/s --
suspected escapes in the `0C` record (not checked).
5. Stored S3 event: client "Terra-Mechanic" (last letter missing) -- unexplained.
6. Page: the Config tab shows the empty write form until Read in serial mode.
7. `/db/events` 500 "database is locked" on the first page load against a new DB.
8. **S3 downloads are stored from the live waveform decoder** (`store.save`), not
the file reader that Series 4 uses (`save_imported_idf`): a histogram gets no
samples and is labelled Waveform. Fix: store S3 downloads through the
file-import path (also aligns event times with v0.32.0).
9. **S3 start over a modem:** the line dropped during the sensor check, the
read-back hit `Broken pipe` and did not reconnect → 503 though the start
worked. Fix: reconnect for the read-back (reads only; the send stays single).
10. Page: "Start monitoring failed:" on a sent-but-unconfirmed change -- wording.
11. S3 stop ~19 s, 11.6 s of it the identity check (a full connect) vs ~1 s for a
serial-only read. **Identified only** (speed is secondary to reliability).
12. Page, serial mode: the Device tab's empty legacy compliance table; S4
Firmware "—" (should say Thor line).
13. S4 mic in the event's peaks "0.0 dBL" vs 96.54 dB(L) in the file -- the
`0x0C` mic denormal parked above, now visible.
14. **After hanging up for a RADIO RING, SFM called the unit straight back up**
(the page's post-change status read). Part of the line-hold decision.
15. **Audit:** the UM20147 stop's record says `sent: null` although `0x97` went out.
16. Page: a 504 on a unit THOR holds should say "connected, but no reply --
another program may be holding this unit's line".
- **Same-second collisions (SDM).** Two events of one unit in the same second collide on (serial, timestamp) — a DB-wide dedup property, not 1b's.
- **423 without `Retry-After` (1c).** Add `Retry-After` to the 423 a request gets while a download holds the unit.
- **A lost `0C` during a Series-3 list (1c).** The strict walk raises on a lost `0A`
or `1F`, but a lost `0C` still lists the event with no timestamp and an
`event_id` ending `:-`. Downloading that id skips the stale check and runs the
full `5A`. If the `0C` is lost again it is refused (no timestamp, no filename);
if it reads, whatever event now sits at that key is stored with no stale check:
self-consistent data, but possibly not the event that was listed. Fix: raise on a lost `0C` in strict mode, or
refuse `:-` ids for Series 3.
- **A lost reply on a Series-3 TCP walk re-runs it once (1c)** under the adapter's
cold-boot retry before the 504, doubling time-to-error on a bad link.
- **A Series-3 download of an already-stored event still runs the full `5A`**
before the database lookup finds it (the lookup is on the SDM side, after the
device layer). Wasted transfer, not bad data (1c).
## Left open by the phase 2 review (2026-10-22)
- **`plan_setup_push` takes any name (phase 5).** It is not tied to the `0x41`
read, and it does not refuse `factory.MMB` or a non-active target, which the
spec requires; the name's case varies (`test2.MMB` vs `test2.mmb`).
- **Stripped-name caveat.** `get_active_setup()` strips whitespace, so a name
with leading or trailing spaces does not round-trip.
- **Bench questions.** Whether a Micromate honours offset 0x0000 on
`0x96`/`0x97`, accepts a no-op call-home write, or accepts 0x00 at `[5]`.
Settle all three at the bench.
- **Phase-5 lead (inferred).** Comparing `0x1A` against the active `.MMB` read
through `0x94`/`0x48` may detect unsaved keypad edits, which would undercut
"can't be detected from the wire". One bench check.
## Left open by the phase 3 review (2026-10-23)
The whole-phase review judged phase 3 ready for the bench, with nothing that
sends twice, sends without an audit row, or sends to an unverified unit. These
items were left for later on purpose:
- **Series-3 change path shape. Settle before the MiniMate bench check.**
- The change path makes one POLL at a 120 s receive timeout, with no retry. A
cold MiniMate that drops that POLL costs 120 s of a locked unit and then a
504. The legacy route retried `poll()` on the same connection at 10 s.
- The identity read is a full `connect()` (POLL, `0x15`, `0x01`, `0x1A`, `0x08`).
The spec asks for one serial read.
- Proposed: 10 s timeouts before the send, one identity-poll retry on the same
connection (a read, never the write), POLL plus `0x15` in place of
`connect()`, and the long timeout only on the read-back polls.
- That needs two measurements first: whether a *monitoring* MiniMate answers
the full `connect()` over TCP, and what `0x1C` reads during the ~40 s sensor
check.
- **For 1c (the webapp).**
- 409 means three things. "Wrong unit" and "unmeasured state" sent nothing;
"mismatch" sent a frame with a clean ack. Only the body tells them apart.
- `ChangeResult.detail` is a dict, so the webapp's `e.detail || r.statusText`
would print `[object Object]`.
- The 60 s verify window, plus the call-up, plus up to 20 s of lock wait,
exceeds the 60 s Terra-View proxy timeout. A mismatch could never be
delivered through that proxy.
- Nothing marks `pending` rows left by a restart mid-change. Reconcile them at
server start only, never on every `SeismoDb` open.
- **A late `0x69` after a lost ack.** When the ack is lost but the follow-up
read validates, the line is kept, and a late `0x69` then breaks the next
unrelated request with a 502. Safe, but confusing. Hanging up after any lost
ack needs a way to release the line on a path that returns a result.
- **Legacy routes take no per-address lock.** They can interleave with an
audited change on the same address. This belongs with the blind-stop-tools
decision, which is still open.
- **Test and scan gaps.**
- The `protocol.execute(` caller scan does not catch an aliased caller.
- Dropping the S4 ack's `data` field is not caught by any test.
- The fake's `fail` queue is also consumed by `read_unsolicited` on the change
path.
- **Docs nits.**
- `s4.py` says `ChangeUnconfirmed` follows "a link fault or a ring". It also
follows a `calling_home` read.
- The 2026-10-02 CLAUDE.md bullet still says "Read-only".
- The route docstrings' 409 line omits the held-line `WrongUnit`.
- **For the merge to dev.** The changelog states: a new `device_commands` table
(`CREATE TABLE IF NOT EXISTS`) plus a `_migrate` step that adds `sent` and
`states` to tables created from this branch. Prod: no migration, no backfill.
- **The MiniMate bench fixes, for the changelog** (2026-10-25, reviewed).
- **The body builder changed in the codec library** (`blastware_file.py`).
`TOOL_VERSION` is not bumped, because no stored file is affected, so nothing
is owed. The `.h5` regenerated from an `.a5.pkl` *would* change for a
non-first event, but no store holds one (below).
- **Operational consequence: none.** Measured: the dev store holds 0
`.a5.pkl` files. Inferred: prod runs no SFM receivers, and it ingests
Blastware's own files, which these functions never touch.
- The commit `352f694` says ".a5.pkl sidecars can rebuild them". That is
wrong: no tool rewrites the event file.
- **Behaviour change.** A probe timeout in a one-event download was
`502 "no waveform data received"`. It is now `NoAnswer` 504, and over TCP
it is retried once as a whole new session. That is a read, so it is
acceptable.
- **Orphaned diagnostic rows.** `be12599-diag`'s `ach_state.json` and its DB
key BE9557 as `'BE9557\x00G'`, the old serial bug. That is diagnostic data
only. SQLite `GLOB` stops at the NUL, so search with `hex()`.
- **Bench-test first, then decide.** A unit that answers a re-poll more than
2 s late, or answers polls it buffered while booting, could leave an extra A4
that is taken as `POLL_DATA`'s reply. `connect()` then fails at the `0x15`
check: an error, never corruption. A short drain after the re-poll would fix
it if a bench shows it happens.
- **The download check refuses what it cannot classify** (inferred, untested
configurations). A waveform with the geophones disabled (MicL only) leaves
Tran/Vert/Long empty, takes the histogram path and is refused; before
`c32a9e7` it was stored unverified. Histogram+Continuous events have never
been downloaded over 5A either. That is failing safe by design. A bench
check on such a unit decides whether a MicL-only branch (END check, no peaks)
is needed.
## Table 2: to be added later (both series)
| area | item |
|---|---|
| infrastructure | async jobs; auth via Terra-View |
| THOR has it, SFM doesn't | clock set; remote sensor check; scheduler; one setup to many units; restart |
| call-home receiver | hold lines open (S4); "already downloaded" tracking; rules by serial prefix (copy events, monitor log, delete, set clock); detect "Monitor While Calling Home" blocking deletes (⚠ one unexplained 21 → 5 count drop in THOR's log); hand off to `/db/import/*` instead of the watchers |
| settings, the no-PC-files way | intended settings per deployment; drift report (intended vs actual); push then verify |
| notifications | email/SMS by event type and PPV (THOR does it; may belong in Terra-View) |
| emergency tools for S4 | if a Micromate ever needs them |
## Parking lot
- **Deleting events after a call-in is the call-in receiver's job, not 1c's**
(Brian, 2026-10-29). In production Blastware ACH (Series 3) and THOR (Series
4) download, then delete; SFM gets the files afterwards from the watchers. If
SFM ever becomes the receiver, deletion comes with it:
- the protocol is already mapped: erase-all `A3 → 1C → 06 → A2` (S3), and
per-event `0xA8` + `0xAA` (S4);
- "Monitor While Calling Home" silently blocks erase while reporting
success, so the server-side high-water mark is load-bearing;
- `0xA2` means CONFIRM ERASE on S3 and END CALL on S4.
1c touches only Diagnostics' S3 erase-all, which it gates to a confirmed
Series-3 unit, server- and page-side.
- **Speed (Brian's goal: faster than Blastware), after 1c.** Measured on
BE9441, 2026-10-27 23:41, serial cable:
- wake + serial number take 0.16 s;
- `MiniMateClient.connect()` also reads 01 + 1A + 08 on every request, ~3 s;
- a fixed **2.0 s "safety drain"** at the end of `read_compliance_config` runs
on every connect;
- the read-back polls every 2 s.
Ideas, each measured before and after against Blastware's own timings in the
bridge recordings: a light connect (wake + serial) for start/stop, status and
event list; drop or shorten the drain; reuse within a session (MiniMates
reconnect per request). New safeguards must state their time cost
(1c's identity check reuses the serial read connect already does).
**Monitor logs.** Its own piece of work, data side as much as device side.
A unit calls in at least once or twice a day. With no events (e.g. waveform
mode, no blast that day) it still delivers a **monitor log**: "monitoring from
X to Y". The watchers (one for BW-ACH / Series 3, one for THOR-ACH / Series 4)
use the newest file per unit, event or `.MLG`, as SFM's "last heard from" age.
They forward waveform and histogram files but **not** monitor logs. To decide:
- Ingest call-in monitor logs into SFM. SFM's DB **already has** a
`monitor_log` table (one row per interval, deduped by serial + start time),
and `minimateplus/blastware_file.py` already parses Series-3 `.MLG`.
Missing: anything that takes `.MLG` in from the watchers, and knowledge of
THOR's Series-4 monitor-log file format.
- A live monitor-log read over a connection (Series 4: `0x0A` exists, no
wrapper or decoder; Series 3 in SFM: none).
- What it is for: proof of coverage ("was it monitoring when they blasted?")
and visible gaps.
- Related fix-list item: `ach_server.py`'s `seen_keys`.
**How SFM handles setup files and schedules.** This phase only reads and
pushes the unit's *active* setup, with no PC-side library (the `.mmb`
same-name/different-contents gotcha). Still to decide, as one question because
the two are coupled:
- The unit stores up to 25 named `.MMB` files. Should SFM manage them (list,
select, rename, delete, push to a named file), or only ever touch the active
one?
- **Schedules name setup files.** A schedule entry switches the unit to a
setup by name, so a schedule is only as reliable as the files it points to.
What if it points to a file that isn't there? That is untested.
- How "intended settings per deployment" (Table 2) fits with files and
schedules.
- Scheduler read/write is mostly mapped (file transfer + `0x47`); **disable has
never been captured**.
**A modem-side agent on the RX55.** AirLink
OS on the RX55 has "Container Applications (Early Adopter)", and Brian already
runs `slmm-proxy` there. A small program owning the unit's serial port could:
- let THOR and SFM share the line
- dial out to SFM, avoiding the IP whitelist
- handle `RADIO RING` locally
- **Brian's hunch:** make RX55s work with Series 3 by driving DTR/DCD itself
Open questions:
- Can a container open the RS-232 port?
- Can it set the control lines?
- How is it deployed to a fleet, and does it Autostart?
- Will a firmware update keep the beta feature?
## Open questions this design leaves for the bench
- **Ring path and retries: does a Micromate's call-home reach THOR when SFM
holds its line?** (Test designed 2026-10-23; decides whether 1c needs a
cool-down.)
- *Already measured (10-14):* with THOR holding the line, the ring arrived on
THOR's own outbound connection (`TcpClientSystemNet ... RADIO RING IS
RECEIVED FROM IP:...:9034`), so the modem did not divert it to the
destination. Unmeasured: the same with SFM as the holder, and what the
unit does after the holder releases.
- *Known from the firmware strings:* "three attempts and it's over".
🔶 Inferred: 60 s between attempts (`0x2C` content `[120:122]` = `00 3c`,
Series III's "time between retries" offset), and about 21 s of ringing per
attempt (10-14 capture).
- ~~*Setup:* a bench Micromate on a modem whose destination is the office
THOR-ACH server, and a unit THOR is not otherwise watching.~~
**Revised 2026-10-29:** THOR receives a call-home on its *own* connection to
the unit (10-14, measured), so a unit THOR does not watch would not test the
production path. And THOR's watchdog interval is a THOR setting -- every 5 s,
hourly, or never (Brian) -- so the runs vary it on purpose.
- *Setup:* UM20147 added to THOR as a test unit, its modem's destination set to
the office THOR server. SFM runs from the parity branch on a test port with
a scratch DB and a timestamped log (it logs every ring and hang-up). THOR's
ACH log open; note THOR's clock against ours. Run after the 1c bench pass:
the call-home uploads UM20147's events, and may erase them per THOR's
test-unit settings.
- **Run 0, baseline (watchdog never, nobody on the line):** trigger a
call-home. Does it reach THOR -- i.e. does the modem dial out by itself?
- **Run A, one call-up (watchdog never):** SFM calls the unit up and holds
the line (any serial-named read). Trigger a call-home. Record:
- whether SFM logs the RADIO RING and hangs up, with the time;
- whether and when THOR starts a session (its ACH log);
- the number and spacing of rings and attempts.
- **Run A2 (watchdog at the fleet's setting):** as A, with THOR competing for
the line. First: can SFM get on at all, and does a watchdog check hold the
line or drop it? Then: after SFM hangs up on the ring, does THOR get back on
before the unit's next attempt?
- **Run B, a poller (watchdog at the fleet's setting):** as A2, but a script
requests the unit's status every ~10 s throughout. If THOR still gets the
call, no cool-down is needed; if the poller keeps the call from reaching
THOR, build it, sized from Run A.
- *Also settles:* whether the modem routes a call-home to its destination
on its own (Run 0), in which case SFM never sees a ring and THOR gets the call
while SFM is still connected.
- **Results, 2026-10-29** (UM20147 on a fleet-config RX55 at `63.45.161.30`,
added to THOR as a test unit; THOR log `C:\THORDATA\Logs\`; all measured
unless marked):
- **Run A (watchdog off, SFM holding the line).** SFM's stop (`0x97`,
20:21:13.001) was answered by `RADIO RING` instead of its ack (20:21:13.7);
SFM hung up. The page's post-change status read called the unit straight
back up (20:21:13.8 → held to 20:21:47; the reaper listens every 5 s, no
second ring). The unit showed "connecting..." → "call home data
transfer..." for under a minute → idle, **no retry**; THOR logged nothing
for the unit through 20:23:57.
- **Run 0 (watchdog off, nobody on the line, keypad start/stop).** The modem
dialled `50.197.32.91:12345`: `ListenerAchTcp - Connection accepted from
63.45.161.30:36648` (20:37:28.5) → serial → `RADIO RING IS RECEIVED` on that
connection → a full THOR session (count 8, download, **DeleteEventState**
per event, reports, email, Vision). SFM sent nothing 20:22–20:37.
- **A2, step 1 (THOR polling, ~5–15 s).** An SFM status read at 20:44:35.9:
the modem accepted the connection, 0 bytes back in 10 s (504). THOR's reads
of the unit at 20:44:37.4 and 20:44:44.3 were answered; no disconnect.
- **Conclusion:** the risk is confined to when THOR is not holding the line
(watchdog off, THOR down, reconnect gaps), and a cool-down would not fix
it. Run B (a poller) is deprioritised: while THOR polls it only collects
504s; the open point is a reconnect gap.
- Also seen: after a manual THOR Disconnect (19:48:07) the unit answered
nobody until a reset (back 20:16:51); THOR's reconnect logged `Mismatch
connection found`. Cause unknown.
- The ack for start/stop when the unit is already in that state.
✅ **Answered for stop (2026-10-25, UM20147):** a stop sent to an idle unit
is acked `0x68` in 10 ms (twice) and changes nothing: not the state, the
events, memory or the screen. Start while already monitoring has not been
tried. Also measured at that bench: `0x49` reads `0x01` for ~18 s after a
real stop. Its meaning is inferred to be the unit's call-home attempts, and
Run A/B can settle it: the inference predicts `0x01` → `0x03` when the modem
connects.
- The offset rule, and whether `0x68`/`0x82` are required, for the setup push.
- Whether the device ever refuses a write while monitoring. Only THOR's policy
has been seen.
- How a failed write is signalled. It has never been observed.
- MiniMate behaviour with a held session (above).
+647
View File
@@ -0,0 +1,647 @@
"""
client.py — high-level API for a live Micromate (Series IV).
Owns the transport, turns raw payloads into models. Read-only, like the layer
below it: nothing here writes, erases, or changes monitoring state, and the
protocol's opcode gate (`micromate.opcodes`) enforces that in code.
with MicromateClient(TcpTransport("63.45.161.30", 9034)) as mm:
info = mm.connect()
print(info) # UM12947 MM/ISEE/S/IO blastware fw idle
print(mm.get_state()) # idle 2026-09-25 01:14:05 3.80 V memory 0.4% used
for name in mm.list_setups():
print(name)
The response layout, measured rather than assumed
-------------------------------------------------
**Every response carries an 11-byte prefix, and the content starts at
``data[11]``.** That one rule covers every command.
⚠ **``data[0]`` looks like the content length and is only its low byte.** A
2,092-byte setup block (`SUB 0x1A`) reports 44, and a 1,024-byte download chunk
reports 0. It happens to be right for every response shorter than 256 bytes,
which is most of them — so it reads as a working length field right up until it
silently loses 2,048 bytes. There is no high byte anywhere in the prefix; it is
``length & 0xFF`` and nothing more.
This is the same trap as ``MicromateFrame.probe_length``, in a different place,
and it is now the third time a length in this protocol has been read too narrow.
**Take the content as ``data[11:]`` and let the frame's own length bound it.**
"""
from __future__ import annotations
import datetime
import logging
import math
import os
import struct
from typing import Optional
from minimateplus.transport import BaseTransport
from .models import (
MicromateDeviceInfo,
MicromateEventRef,
MicromateRunState,
MicromateSetup,
MicromateState,
)
from .protocol import MicromateProtocol, ProtocolError
from .setup_block import decode_setup
log = logging.getLogger(__name__)
# The content of every response begins here; the first 11 bytes are a prefix
# whose only decoded field is an unreliable low-byte length (see module docstring).
CONTENT = 11
# Field offsets, relative to the start of content. Sources are named because
# two of them disagree with docs/micromate_protocol_reference.md.
_STATE_FLAG = 0 # 0x49: 0x00 idle, 0x02 monitoring
# 0x06 storage range. content[0:4] is the event count: 3/3 against the chain
# walk, and THOR's ReadEventRecordCount agrees. content[4:8] is very likely
# the monitor-log count -- graded a strong candidate, not settled, so not exposed.
_SR_EVENT_COUNT = slice(0, 4)
_MS_FLAG = 1 # 0x1C: monitoring flag — test NON-ZERO
_MS_DAY, _MS_MONTH, _MS_YEAR = 2, 3, slice(4, 6)
_MS_UNKNOWN_6 = 6 # ⚠ sub-second tick (~4020/s, step 4, 64 ms wrap) — NOT the hour
_MS_HOUR, _MS_MIN, _MS_SEC = 7, 8, 9
_MS_BATTERY = slice(34, 36) # uint16 BE, volts × 100
_MS_MEM_TOTAL = slice(36, 40) # uint32 BE
_MS_MEM_FREE = slice(40, 44) # uint32 BE
# `SUB 0x0C` record, relative to content. Established against 7 events across
# both firmware lines.
_REC_DAY, _REC_MONTH, _REC_YEAR = 0, 1, slice(2, 4)
_REC_UNKNOWN_4 = 4 # ⚠ same shape as 0x1C's content[6]; undecoded
_REC_HOUR, _REC_MIN, _REC_SEC = 5, 6, 7
_REC_TYPE = 11 # 0x07 waveform, 0x08 histogram
_REC_LOCATION = 12
_REC_SETUP = 34
_REC_SERIAL = 76
_RECORD_TYPES = {0x07: "waveform", 0x08: "histogram"}
# The channel labels the record carries, in the order they appear. The peak
# float sits `label + 6`; the peak vector sum sits 12 bytes BEFORE "Tran".
_REC_CHANNELS = (b"Tran", b"Vert", b"Long", b"Mic")
_REC_PVS_BACK = 12
# A chain walk terminates on an all-zero key. The ceilings below are guards
# against a device cursor that never advances, not fleet limits.
_NULL_KEY = bytes(4)
_MAX_EVENTS = 4096
# A setup-list walk that does not terminate is a bug, not a big fleet. The
# bench unit holds 22 setups; this is a generous ceiling, not a limit.
_MAX_SETUPS = 512
def _content(data: bytes) -> bytes:
"""Strip the 11-byte response prefix."""
return data[CONTENT:] if len(data) > CONTENT else b""
def _cstring(buf: bytes, offset: int = 0) -> str:
"""A null-terminated ASCII run, stripped."""
return buf[offset:].split(b"\x00")[0].decode("ascii", "replace").strip()
class DecodeMismatch(ProtocolError):
"""Our decoded peak disagrees with the one the device computed itself."""
class MicromateClient:
"""High-level read-only client for one Micromate.
Owns the transport, unlike ``MicromateProtocol``, which borrows it.
"""
def __init__(
self,
transport: BaseTransport,
recv_timeout: float = 10.0,
strict_checksums: bool = True,
) -> None:
self._transport = transport
self._proto = MicromateProtocol(
transport, recv_timeout=recv_timeout, strict_checksums=strict_checksums
)
self._firmware_line: Optional[str] = None
self._serial: Optional[str] = None
# ── Lifecycle ─────────────────────────────────────────────────────────────
def open(self) -> None:
self._transport.connect()
def close(self) -> None:
self._transport.disconnect()
def is_open(self) -> bool:
# `is_connected` is a PROPERTY on BaseTransport. Calling it raised
# TypeError on every real transport; only a test double that defined
# it as a method hid that.
return bool(self._transport.is_connected)
def __enter__(self) -> "MicromateClient":
self.open()
return self
def __exit__(self, *_) -> None:
self.close()
@property
def protocol(self) -> MicromateProtocol:
"""The wire layer, for anything this class does not wrap yet."""
return self._proto
# ── Identity ──────────────────────────────────────────────────────────────
def connect(self, *, with_active_setup: bool = True) -> MicromateDeviceInfo:
"""`POLL → SERIAL → state`, plus the active setup name.
⚠ **This is deliberately not Thor's full preamble.** Thor sends
`POLL → SERIAL → 0x49 → POLL` and the client spec said to copy it
verbatim on the grounds that it is known-good. Measuring all 8 captured
sessions showed the only invariant is that a session **opens with
POLL** — the four-command form appears in 3 of 8 and is Thor's
*connection check*, run where it wants to refresh what it displays. The
trailing POLL is a repeat of the first.
So this sends the three reads that actually gather something. Dropping
the fourth is a judgement call on measured evidence, not a proof that
nothing depends on it; if a unit ever refuses the next command after a
cold connect, put it back and say so in the protocol reference.
`SUB 0x01` (device info) is **not** read. Thor never reads it in any
captured session, its field layout is unmapped beyond eight `1.0f`
floats, and `firmware_line` — the one thing we would want from it — comes
free from the flags byte of any response.
"""
poll = self._proto.poll()
self._firmware_line = poll.firmware_line
manufacturer, model = self._parse_poll(poll.data)
serial = _cstring(_content(self._proto.read_serial()))
self._serial = serial
monitoring = self._parse_state(self._proto.read_state())
info = MicromateDeviceInfo(
serial=serial,
manufacturer=manufacturer,
model=model,
firmware_line=poll.firmware_line,
monitoring=monitoring,
)
if with_active_setup:
try:
info.active_setup = self.get_active_setup()
except ProtocolError as e:
# Not worth failing a connect over: a unit with no setup loaded
# is a real state, and the caller can still read everything else.
log.warning("active setup unreadable: %s", e)
log.info("connected: %s", info)
return info
@staticmethod
def _parse_poll(data: bytes) -> tuple[Optional[str], Optional[str]]:
"""Manufacturer and model out of the POLL block.
`Instantel` sits at content[4] and the model at content[26], with 13
binary bytes between them.
⚠ A generic "find the printable runs" scan does **not** work here, which
cost a test failure before it cost anything worse. content[3] is `0x50`
— printable as `P` — sitting immediately before `Instantel`, so a run
scan returns `PInstantel`. Nothing distinguishes a length or tag byte
from text by inspection.
So: the manufacturer comes from a fixed offset, and the model is found by
searching for `MM/`. That anchor is structural rather than positional,
which matters because the model string **differs by firmware line** —
`MM/ISEE/S/IO` on the Blastware build, `MM/ISEE/S` on the Thor build —
and only its tail changes.
"""
c = _content(data)
manufacturer = _cstring(c, 4) or None
idx = c.find(b"MM/")
model = _cstring(c, idx) if idx >= 0 else None
return manufacturer, model
@staticmethod
def _parse_state(data: bytes) -> Optional[bool]:
"""`SUB 0x49` content[0]: 0x00 idle, 0x02 monitoring.
⚠ Tested for non-zero, never against `0x02`. The sibling flag in
`SUB 0x1C` has read both `0x0E` and `0x0C` while monitoring, so this
family of flags is not a stable enum.
"""
c = _content(data)
return bool(c[_STATE_FLAG]) if c else None
# ── State ─────────────────────────────────────────────────────────────────
def get_state(self) -> MicromateState:
"""`SUB 0x1C` — monitoring, device clock, battery, memory.
⚠ Every offset here is **forward from the start of content**, never
backward from the end. Series III reads battery and memory from the end
of this block, and this block is **4 bytes longer on the Thor firmware
line** — applying from-the-end offsets to a `11.0BD` unit yields a
battery voltage of 577.92 V. The four extra bytes are trailing, so
from-the-start offsets hold for both lines.
✅ **Confirmed on `11.0BD` 2026-09-30.** UM20147 read back 3.55 V and
a clock correct to the second over USB, so the from-the-start offsets do
survive the four extra trailing bytes. Had they not, the battery would
have read 577.92 V — which is what makes this cheap to check.
"""
data = self._proto.read_monitor_status()
c = _content(data)
if len(c) < 44:
raise ProtocolError(
f"monitor status content is {len(c)} B, need at least 44"
)
battery = int.from_bytes(c[_MS_BATTERY], "big") / 100.0
return MicromateState(
monitoring=bool(c[_MS_FLAG]),
device_time=self._parse_clock(c),
battery_volts=battery,
memory_total_bytes=int.from_bytes(c[_MS_MEM_TOTAL], "big"),
memory_free_bytes=int.from_bytes(c[_MS_MEM_FREE], "big"),
raw=data,
)
def get_event_count(self) -> int:
"""`SUB 0x06` -- events stored. One read; no chain walk."""
c = _content(self._proto.read_storage_range())
if len(c) < 4:
raise ProtocolError(f"storage range content is {len(c)} B, need at least 4")
return int.from_bytes(c[_SR_EVENT_COUNT], "big")
def read_unsolicited(self) -> bytes:
"""Whatever the unit sent unprompted. **Sends nothing.**
One transport read. Bytes between commands are noise to the protocol
(every request resets the parser), so reading them here takes nothing
the protocol needs. A session calls this while idle to notice
RADIO RING without waiting for its next keep-alive.
"""
return self._transport.read(4096)
@staticmethod
def _parse_clock(c: bytes) -> Optional[datetime.datetime]:
"""The unit's own clock, in its own local time.
⚠ **content[6] is not part of the time.** The layout is day, month,
year, *one unidentified byte*, then h/m/s — so the hour is at content[7].
The protocol reference's `SUB 0x1C` section has this right and names
`data[17]` as unidentified; its one-line summary in the divergences list
("day/month/year/h/m/s at `data[13:21]`") reads as six contiguous fields
and is the version worth not trusting.
Re-measured here across three captures: content[6] read 32, 100 and 116,
none a valid hour, while content[7:10] gave 19:12:25, 19:13:34 and
01:14:05 against capture filenames stamped 19:12:14, 19:12:14 and
01:14:03 — each seconds to a minute after its session opened, which is
what a device clock should do.
content[6] is undecoded and deliberately not exposed.
"""
try:
return datetime.datetime(
year=int.from_bytes(c[_MS_YEAR], "big"),
month=c[_MS_MONTH],
day=c[_MS_DAY],
hour=c[_MS_HOUR],
minute=c[_MS_MIN],
second=c[_MS_SEC],
)
except ValueError as e:
# A unit with a dead clock battery reports an impossible date. That
# is information, not a reason to fail the whole state read.
log.warning("device clock unreadable (%s): %s", e, c[2:10].hex(" "))
return None
# ── Setups ────────────────────────────────────────────────────────────────
def get_active_setup(self) -> str:
"""`SUB 0x41` — the loaded `.MMB` file name, e.g. `TEST1.mmb`."""
return _cstring(_content(self._proto.read_active_setup_name()))
def get_setup(self, *, verify: bool = True) -> MicromateSetup:
"""`SUB 0x1A` — what the unit is set to, decoded. One read.
Raises ``SetupChecksumError`` if the block's CRC fails, unless
``verify=False``. Offsets and what is deliberately not decoded are in
``micromate/setup_block.py``.
⚠ This reads the keypad's EDIT BUFFER: if someone is in the unit's setup
menu, unsaved values come back.
"""
return decode_setup(_content(self._proto.read_compliance_config()), verify=verify)
def list_setups(self) -> list[str]:
"""`0x3F` then `0x40`… — every setup file stored on the unit.
A cursor walk: the device holds the position, so the same `0x40` request
returns the next name. **An empty name terminates the list** — it is
not an error and not a real setup.
Measured on the bench unit: 23 responses, 22 names then the empty one,
`factory.MMB` first through `TEST1.mmb` last.
"""
names: list[str] = []
raw = self._proto.read_first_setup()
for _ in range(_MAX_SETUPS):
name = _cstring(_content(raw))
if not name:
return names
names.append(name)
raw = self._proto.read_next_setup()
raise ProtocolError(
f"setup list did not terminate after {_MAX_SETUPS} entries — the "
f"device cursor is not advancing"
)
# ── Events ────────────────────────────────────────────────────────────────
def serial(self, *, refresh: bool = False) -> str:
"""The unit's serial, cached from `connect()` or read on demand.
Needed by anything that handles an event, because an event key is
ambiguous without it — see `MicromateEventRef`.
`refresh=True` forces a fresh `0x15` read. A change operation passes it
right before writing, so the identity check never runs against a serial
cached from an earlier call-up (a modem may have moved to another unit).
"""
if refresh or self._serial is None:
self._serial = _cstring(_content(self._proto.read_serial()))
return self._serial
# Anything else reads unknown(0x..): the safe default, which the change path refuses.
_RUN_STATES = {0x00: "idle", 0x02: "monitoring", 0x03: "calling_home"}
def read_run_state(self) -> MicromateRunState:
"""`SUB 0x49` -> the unit's run state, with the in-call-home value kept
(connect()'s `monitoring` bool flattens 0x03 into True)."""
c = _content(self._proto.read_state())
if not c:
raise ProtocolError("0x49 state reply has no content")
code = c[_STATE_FLAG]
return MicromateRunState(code, self._RUN_STATES.get(code, f"unknown(0x{code:02X})"))
def list_events(self, *, with_records: bool = True) -> list[MicromateEventRef]:
"""Walk the event chain. `0x93 → 1E`, then `0x93 → 1F` until the sentinel.
THOR sends `0x93` before **every** chain read, and this mirrors that.
The chain ends on an all-zero key.
⚠ `with_records=True` costs **one extra round trip per event** for the
`0x0C` read, and over cellular a round trip is ~0.65 s regardless of
size. On a unit with 40 events that is the difference between ~52 s and
~78 s. Pass False when you only need "what is here and how big" — but
note the **record is where the type and timestamp live**, so without it
`ref.filename` is None and `get_event()` cannot pick a suffix.
⚠ **To download, prefer `iter_events()`.** This walks the whole chain
first; THOR interleaves, downloading each event before advancing.
`0x5A` addresses an event by key, so downloading afterwards *should*
work — but "should" is doing real work in that sentence, and the
interleaved order is the one with captures behind it. See
`iter_events()`.
"""
serial = self.serial()
refs: list[MicromateEventRef] = []
for i in range(_MAX_EVENTS):
self._proto.arm_event()
raw = (self._proto.read_event_first() if i == 0
else self._proto.read_event_next())
c = _content(raw)
if len(c) < 8:
raise ProtocolError(
f"chain entry {i}: {len(c)} B of content, need 8 (key + size)"
)
key, size = c[0:4], int.from_bytes(c[4:8], "big")
if key == _NULL_KEY:
return refs # the sentinel, not an error
ref = MicromateEventRef(index=i, key=key, size=size, serial=serial)
if with_records:
self._read_record_into(ref)
refs.append(ref)
raise ProtocolError(
f"event chain did not terminate after {_MAX_EVENTS} entries — the "
f"device cursor is not advancing"
)
def iter_events(self, *, with_records: bool = True):
"""Walk the chain, yielding each event **at the cursor position THOR uses.**
for ref in mm.iter_events():
if ref.is_histogram:
continue
data = mm.download_event(ref) # ← safe here
Why this exists alongside `list_events()`: THOR's captured order is
0x93 → 1E → 0C → 5A×n → 0x93 → 1F → 0C → 5A×n → …
— it downloads each event *before* advancing the chain. `list_events()`
walks to the end first, which is fine for browsing (the browse walk is
separately attested) but means a later download happens with the device
cursor parked past the event. `0x5A` is key-addressed, so it very
probably does not care; nothing observed says it does, and nothing
observed says it does not.
Downloading inside this loop reproduces THOR's sequence exactly, so it
is the path to use when it matters. ⚠ Do not advance the generator
before finishing with the event it yielded.
"""
serial = self.serial()
for i in range(_MAX_EVENTS):
self._proto.arm_event()
raw = (self._proto.read_event_first() if i == 0
else self._proto.read_event_next())
c = _content(raw)
if len(c) < 8:
raise ProtocolError(
f"chain entry {i}: {len(c)} B of content, need 8 (key + size)"
)
key, size = c[0:4], int.from_bytes(c[4:8], "big")
if key == _NULL_KEY:
return
ref = MicromateEventRef(index=i, key=key, size=size, serial=serial)
if with_records:
self._read_record_into(ref)
yield ref
raise ProtocolError(
f"event chain did not terminate after {_MAX_EVENTS} entries — the "
f"device cursor is not advancing"
)
def _read_record_into(self, ref: MicromateEventRef) -> None:
"""`SUB 0x0C` — 210 B of content: timestamp, type, names, peaks."""
raw = self._proto.read_event_record(ref.key)
c = _content(raw)
if len(c) <= _REC_SERIAL:
raise ProtocolError(f"event record is {len(c)} B, too short to decode")
ref.raw_record = raw
ref.record_type = _RECORD_TYPES.get(c[_REC_TYPE])
if ref.record_type is None:
# Worth saying out loud rather than filing the event as a waveform:
# the suffix decides which codec runs.
log.warning("event %s: unknown record type 0x%02x at content[%d]",
ref.key_hex, c[_REC_TYPE], _REC_TYPE)
try:
ref.timestamp = datetime.datetime(
year=int.from_bytes(c[_REC_YEAR], "big"),
month=c[_REC_MONTH], day=c[_REC_DAY],
hour=c[_REC_HOUR], minute=c[_REC_MIN], second=c[_REC_SEC],
)
except ValueError as e:
log.warning("event %s: bad timestamp (%s): %s",
ref.key_hex, e, c[:8].hex(" "))
ref.sensor_location = _cstring(c, _REC_LOCATION) or None
ref.setup = _cstring(c, _REC_SETUP) or None
# Prefer the record's own serial over the cached one — they have always
# agreed, but the record is the event's own account of where it came from.
if rec_serial := _cstring(c, _REC_SERIAL):
ref.serial = rec_serial
peaks: dict[str, float] = {}
for label in _REC_CHANNELS:
i = c.find(label)
if i < 0 or i + len(label) + 10 > len(c):
continue
peaks[label.decode()] = struct.unpack(
">f", c[i + len(label) + 2: i + len(label) + 6])[0]
ref.peaks_ips = peaks or None
tran = c.find(b"Tran")
if tran >= _REC_PVS_BACK:
ref.peak_vector_sum_ips = struct.unpack(
">f", c[tran - _REC_PVS_BACK: tran - _REC_PVS_BACK + 4])[0]
def download_event(self, ref: MicromateEventRef, *,
chunk_size: Optional[int] = None) -> bytes:
"""The raw `.IDFW`/`.IDFH` bytes, exactly as THOR would have stored them.
Feeds `micromate.idf_file.read_idf_file()` and `/db/import/idf_file`
unchanged — no new codec work is needed for a directly downloaded event.
`chunk_size` defaults to the measured device ceiling (16,384 B), which is
16x THOR's 1024 and therefore ~14x fewer round trips on a large event.
Pass `THOR_CHUNK_SIZE` to reproduce THOR's wire traffic exactly, or a
smaller value on a link where big responses are not surviving.
"""
kw = {} if chunk_size is None else {"chunk_size": chunk_size}
return self._proto.read_event_file(ref.key, ref.size, **kw)
def get_event(self, ref: MicromateEventRef, *, verify: bool = True,
tolerance: float = 0.01, chunk_size: Optional[int] = None):
"""Download and decode one event.
Returns the codec's `IdfReadResult`. Needs `ref.record_type`, since
`read_idf_file()` dispatches on the filename suffix and there is no
filename on the wire — so call `list_events(with_records=True)` first.
⚠ `verify=True` re-computes the **peak vector sum** from the decoded
samples and compares it against the float the *device* put in the `0x0C`
record. Those are two independent computations over the same samples —
the device's from its own firmware, ours from our codec — so a
disagreement means our decode is wrong. Measured agreement on the bench
events is **0.000%**.
This is cheap insurance in a codebase whose decode failures have
historically been *silent*: unhandled block tags shorten a channel and
nothing raises. ⚠ It is a decode-correctness check, **not** a
truncation detector — a channel cut after its peak still yields the
right PVS.
Histograms are not verified: `samples` is empty for them.
"""
return self.fetch_event(ref, verify=verify, tolerance=tolerance,
chunk_size=chunk_size)[1]
def fetch_event(self, ref: MicromateEventRef, *, verify: bool = True,
tolerance: float = 0.01, chunk_size: Optional[int] = None):
"""`get_event()`, returning the raw bytes too: `(blob, result)`.
For a caller that stores the file AND wants the self-check: the bytes go
to the waveform store unchanged, and a DecodeMismatch stops them being
stored at all.
"""
if not ref.record_type:
raise ValueError(
f"event {ref.key_hex}: record_type is unknown, so the codec "
f"cannot be dispatched. Use list_events(with_records=True)."
)
blob = self.download_event(ref, chunk_size=chunk_size)
import tempfile
from .idf_file import read_idf_file
# read_idf_file dispatches on the suffix, so the bytes need a name.
with tempfile.NamedTemporaryFile(suffix=ref.suffix, delete=False) as f:
f.write(blob)
tmp = f.name
try:
result = read_idf_file(tmp)
finally:
os.unlink(tmp)
if verify and not ref.is_histogram:
err = self.decode_error(ref, result)
if err is not None and abs(err) > tolerance:
raise DecodeMismatch(
f"event {ref.uid}: decoded peak vector sum differs from the "
f"device's own by {100 * err:+.3f}% (tolerance "
f"{100 * tolerance:.1f}%) — the decode is suspect, not the "
f"device. Stored {ref.peak_vector_sum_ips:.5f} in/s."
)
if err is not None:
log.debug("event %s: PVS agrees to %+.4f%%", ref.uid, 100 * err)
return blob, result
@staticmethod
def decode_error(ref: MicromateEventRef, result) -> Optional[float]:
"""Relative error between our decoded PVS and the device's stored one.
None when either side is unavailable. Positive means the device's
figure is higher than ours.
"""
from .idf_file import geo_count_to_ips
stored = ref.peak_vector_sum_ips
if not stored or not getattr(result, "samples", None):
return None
ch = {k.lower(): v for k, v in result.samples.items()}
try:
t, v, l = ch["tran"], ch["vert"], ch["long"]
except KeyError:
return None
n = min(len(t), len(v), len(l))
if not n:
return None
pvs = max(
math.sqrt(geo_count_to_ips(t[i]) ** 2
+ geo_count_to_ips(v[i]) ** 2
+ geo_count_to_ips(l[i]) ** 2)
for i in range(n)
)
return (stored - pvs) / pvs if pvs else None
+330
View File
@@ -0,0 +1,330 @@
"""
framing.py — frame codec for the Instantel Micromate (Series IV) wire protocol.
A Micromate answers Series III *command* frames, so the request side looks
familiar. The framing underneath is not the same, and the differences are all
of the kind that produce a silently-ignored frame rather than an error:
Series III response: [DLE 0x10] [STX 0x02] … [chk] [ETX 0x03]
Micromate response: [STX 0x02] … [chk] [ETX 0x03]
^ no leading DLE
That missing byte is why `minimateplus.framing.S3FrameParser` returns *nothing*
on Micromate traffic — it locates frames by scanning for `DLE STX`, which never
occurs. A capture holding 12 acknowledged writes reads as 12 unanswered
requests.
De-stuffed payload layout (both directions):
request response
[0] CMD 0x10 [0] CMD 0x00
[1] flags 0x00 [1] flags 0xC5 / 0x03 ← firmware line
[2] SUB [2] SUB 0xFF − request_SUB
[3] 0x00 [3] PAGE_HI
[4] offset_hi [4] PAGE_LO
[5] offset_lo [5+] data
[6:16] params (10 bytes)
Everything below was established against the 251 request and 251 response
frames in `bridges/captures/9-24-26 - micromate2/` (UM12947, firmware 11.0CB).
Where a rule is asserted, the number of frames it was checked on is given — the
two rules that look like small details cost 26% and 22% of frames respectively
when guessed wrong, so the counts are the point.
"""
from __future__ import annotations
from dataclasses import dataclass
from typing import Optional
# ── Protocol byte constants ───────────────────────────────────────────────────
DLE = 0x10 # Data Link Escape
STX = 0x02 # Start of text — begins a frame
ETX = 0x03 # End of text — ends a frame
ACK = 0x41 # Frame-start marker on the request side
MM_CMD = 0x10 # payload[0] in a request
MM_RSP_CMD = 0x00 # payload[0] in a response
# payload[1] of a response identifies the firmware line it came from.
# ⚠ Two units, one of each — a strong hypothesis, not a proven encoding.
FLAGS_BLASTWARE = 0xC5 # the 11.0CB line (UM12947)
FLAGS_THOR = 0x03 # the 11.0BD line (UM20147)
# ⚠ THE ESCAPE SET. A Micromate escapes exactly these four byte values,
# prefixing each with a DLE — and nothing else. Established by re-stuffing
# every captured frame and comparing to the wire: 251/251 responses and 251/251
# requests reproduce byte-for-byte with this set, and no other candidate set
# reproduces even 200 of either.
#
# The two near-misses are worth naming, because both look plausible:
# * `{0x10}` alone — the Series III rule — reproduces 130/251 responses and
# 177/251 requests.
# * adding ACK (0x41) reproduces only 196/251 responses: a literal 0x41 in
# the data is NOT escaped.
_ESCAPED = frozenset({STX, ETX, 0x04, DLE})
# A response header is 5 bytes; a frame must also carry its checksum.
_MIN_PAYLOAD = 5
_REQUEST_PAYLOAD_SIZE = 16
# ── Stuffing ──────────────────────────────────────────────────────────────────
def stuff(data: bytes) -> bytes:
"""Escape every byte the Micromate escapes: `XX` → `10 XX` for the four."""
out = bytearray()
for b in data:
if b in _ESCAPED:
out.append(DLE)
out.append(b)
return bytes(out)
def unstuff(data: bytes) -> bytes:
"""Reverse `stuff()`: `10 XX` → `XX`, for any XX.
Uniform, with no inner-frame carve-out — which is a real simplification
over Series III, where `DLE+ETX` inside a frame is literal data that must
survive de-stuffing. Since only four byte values are ever escaped, taking
*any* `10 XX` as `XX` is exact rather than merely convenient.
"""
out = bytearray()
i = 0
while i < len(data):
if data[i] == DLE and i + 1 < len(data):
out.append(data[i + 1])
i += 2
else:
out.append(data[i])
i += 1
return bytes(out)
# ── Checksum ──────────────────────────────────────────────────────────────────
def checksum(payload: bytes) -> int:
"""SUM8 of the **de-stuffed** payload, mod 256. 251/251 both directions.
⚠ Do NOT exclude `0x10` bytes from this sum. The DLE-aware checksum that
Series III uses for its `5A` and write frames is the right answer to a
*different* question: it pairs with Series III de-stuffing, which leaves
escaped bytes in the payload as two bytes. De-stuffing uniformly already
removes the DLE, so excluding `0x10` as well subtracts the correction
twice.
That combination — uniform de-stuffing *and* an exclusive sum — is what
`scratch/mm_frame_parse.py` shipped with. It disagrees with the wire on
**55 of 251** captured response frames, all of them frames whose payload
holds a literal `0x10`. The script only ever looked correct because it
accepts a frame that matches *either* rule, so it reported those 55 as
plain SUM8 and never flagged one bad.
"""
return sum(payload) & 0xFF
# ── Request builder ───────────────────────────────────────────────────────────
def build_request(sub: int, offset: int = 0, params: bytes = bytes(10), data: bytes = b"") -> bytes:
"""Build a host→unit command frame.
⚠ Do **not** substitute `minimateplus.framing.build_bw_frame()` here, even
though the payload layout is identical. That builder escaped only `0x10`,
so it reproduced just **161 of Thor's 218** captured read frames. (Since
2026-10-26 it escapes the same four values -- a MiniMate wants them too -- but
the Micromate framing differs in other ways; keep the two builders apart.) The 57 it
gets wrong are not edge cases:
* every `SUB 0x5A` bulk download — `offset = 0x0400` puts a literal
`0x04` in `offset_hi`, which must go out as `10 04`
* `SUB 0x47` (scheduler enable), whose params carry a `0x03`
An unescaped `0x03` or `0x04` reads as a frame terminator, so the unit sees
a truncated frame and simply does not answer. That is indistinguishable
from a dead unit, and event download would have hit it on the first try.
With the correct escape set this builder reproduces **218/218**.
Args:
sub: command SUB byte.
offset: uint16 at payload[4:5]. Micromate reads are single-step —
Thor asks for `0xFFFF` and gets the whole block — so this is
usually `0xFFFF`, not Series III's probe-then-data pair.
params: exactly 10 bytes at payload[6:16].
data: the write section after params (empty for every read and for
write confirms). Escaped and checksummed exactly like the rest
of the payload -- reproduces all 33 data-carrying THOR frames.
A `0x10` inside `params` is fine and needs no special handling: Thor sends
`SUB 0x5A` with `params = 00 00 10 00 …` and the wire carries `10 10`.
(This was the spec's one open question; five captured frames settle it.)
"""
if len(params) != 10:
raise ValueError(f"params must be exactly 10 bytes, got {len(params)}")
if not 0 <= offset <= 0xFFFF:
raise ValueError(f"offset must fit in uint16, got {offset:#x}")
if not 0 <= sub <= 0xFF:
raise ValueError(f"sub must be a single byte, got {sub:#x}")
payload = (bytes([MM_CMD, 0x00, sub, 0x00, (offset >> 8) & 0xFF, offset & 0xFF])
+ params + bytes(data))
body = payload + bytes([checksum(payload)])
return bytes([ACK, STX]) + stuff(body) + bytes([ETX])
def request_sub(frame: bytes) -> int:
"""The SUB of a built host->unit frame (`41 02 <stuffed body> 03`).
Used by the protocol's send-side opcode gate, which must see exactly what is
about to go on the wire rather than trust the caller's word for it.
"""
if len(frame) < 5 or frame[0] != ACK or frame[1] != STX or frame[-1] != ETX:
raise ValueError(f"not a host->unit request frame: {bytes(frame[:8]).hex()}")
body = unstuff(frame[2:-1])
if len(body) < 17 or body[0] != MM_CMD:
raise ValueError(f"not a host->unit request frame: {bytes(frame[:8]).hex()}")
# Canonical form only: what this check reads must be exactly what the unit
# parses. An unescaped 02/03/04, a `10 XX` outside {02,03,04,10} or a
# trailing lone DLE would be read one way here and another by the unit.
if stuff(body) != frame[2:-1]:
raise ValueError(
f"not a canonical request frame (stuffing differs): {bytes(frame[:8]).hex()}")
return body[2]
# ── Response frame ────────────────────────────────────────────────────────────
@dataclass
class MicromateFrame:
"""A parsed, de-stuffed unit→host response frame."""
sub: int # response SUB; the request was 0xFF − this
flags: int # payload[1] — 0xC5 Blastware line, 0x03 Thor line
page_hi: int
page_lo: int
data: bytes # payload[5:], checksum stripped
checksum_valid: bool
chk_byte: int = 0 # the checksum byte as received
@property
def request_sub(self) -> int:
"""The SUB this is answering. No known exception to `0xFF − SUB`."""
return 0xFF - self.sub
@property
def page_key(self) -> int:
"""payload[3:5] as a uint16 BE — a page/address on `0x5A` responses."""
return (self.page_hi << 8) | self.page_lo
@property
def firmware_line(self) -> str:
return {FLAGS_BLASTWARE: "blastware", FLAGS_THOR: "thor"}.get(self.flags, "unknown")
@property
def probe_length(self) -> Optional[int]:
"""Data length declared by a **probe** response: uint16 BE at data[3:5].
⚠ Only meaningful in the reply to an `offset = 0` probe. Series III
hardcodes a `DATA_LENGTHS` table; a Micromate will tell you instead,
which already caught one divergence (call-home config is `0x7E`, where
Series III has `0x7C`).
⚠ It is a **uint16 BE**, not a byte. Read as `data[3]` alone it is
right only while the high byte is zero, and wrong by 47x for
`SUB 0x1A`: a true `0x082C` (2092) reads as 44.
Returns None on a frame too short to hold the field. Note this reads
as 0 on the single-step reads Thor actually uses — those are not probes,
and `page_key` is the meaningful field there.
"""
if len(self.data) < 5:
return None
return (self.data[3] << 8) | self.data[4]
# ── Streaming parser ──────────────────────────────────────────────────────────
class MicromateFrameParser:
"""Incremental parser for unit→host frames. Mirrors `S3FrameParser`.
Feed bytes with `feed()`; completed frames are returned and also collected
in `.frames`.
IDLE — scanning for a bare STX
IN_FRAME — collecting; bare ETX terminates
AFTER_DLE — the next byte is literal, whatever it is
Request frames are rejected rather than parsed: a frame whose `payload[0]`
is not `0x00` is dropped, so feeding a bidirectional capture yields only
the responses.
"""
_IDLE, _IN_FRAME, _AFTER_DLE = 0, 1, 2
def __init__(self) -> None:
self._state = self._IDLE
self._body = bytearray()
self.frames: list[MicromateFrame] = []
# Distinguishes "no bytes at all" from "bytes but no complete frame" on
# a timeout. That distinction earned its keep during the Series III
# work and costs one integer here.
self.bytes_fed: int = 0
def reset(self) -> None:
self._state = self._IDLE
self._body.clear()
self.bytes_fed = 0
def feed(self, data: bytes) -> list[MicromateFrame]:
self.bytes_fed += len(data)
completed: list[MicromateFrame] = []
for b in data:
frame = self._step(b)
if frame is not None:
completed.append(frame)
self.frames.append(frame)
return completed
def _step(self, b: int) -> Optional[MicromateFrame]:
if self._state == self._IDLE:
if b == STX:
self._body.clear()
self._state = self._IN_FRAME
# Boot strings, modem RING/CONNECT chatter and stray ACKs land here
# and are discarded.
elif self._state == self._IN_FRAME:
if b == DLE:
self._state = self._AFTER_DLE
elif b == ETX:
self._state = self._IDLE
return self._finalise()
else:
self._body.append(b)
elif self._state == self._AFTER_DLE:
# Uniform rule: the escaped byte is itself, including 0x03.
self._body.append(b)
self._state = self._IN_FRAME
return None
def _finalise(self) -> Optional[MicromateFrame]:
body = bytes(self._body)
if len(body) < _MIN_PAYLOAD + 1:
return None
payload, chk_received = body[:-1], body[-1]
if payload[0] != MM_RSP_CMD:
return None # a request frame, or garbage that framed by accident
return MicromateFrame(
sub = payload[2],
flags = payload[1],
page_hi = payload[3],
page_lo = payload[4],
data = payload[5:],
checksum_valid = (chk_received == checksum(payload)),
chk_byte = chk_received,
)
+225 -44
View File
@@ -47,19 +47,24 @@ from dataclasses import dataclass
from pathlib import Path
from typing import Optional, Union
# Thor IDFW bodies are pinned to the SUPERSEDED tag-dispatch decoder.
# Thor IDFW bodies use the series-3 record-chain decoder.
#
# _find_waveform_body_offset() trial-decodes every candidate offset and keeps
# whichever yields the most samples. The series-3 record-chain decoder
# correctly returns None where the legacy walker returned garbage, which
# changes that heuristic's winner on 33 of 577 files. The net effect measured
# 2026-08-25 was positive (all-channels-equal 8/577 -> 506/577, mean abs PPV
# error 0.228 -> 0.173 in/s) but Thor has no ASCII ground truth in the corpus
# and its geo scaling is separately suspect, so the switch is deferred until
# the body-offset search is reworked to use the record chain directly.
from minimateplus.waveform_codec import (
decode_waveform_legacy as decode_waveform_v2,
)
# This was previously pinned to the SUPERSEDED tag-dispatch walker
# (`decode_waveform_legacy`) on the stated grounds that "Thor has no ASCII
# ground truth in the corpus and its geo scaling is separately suspect".
# Both premises were false: Thor writes a per-sample CSV export next to every
# binary (see scratch/verify_thor_against_csv.py), and the scaling is now
# resolved (see _GEO_LSB_IPS). Measured against that ground truth on
# 2026-09-10, the record chain beats the legacy walker outright:
#
# channel truncation 55/153 files -> 3/153
# files exact 98/153 -> 150/153
# per-sample exact 99.781% -> 99.854%
#
# The legacy walker stops at the first unrecognised tag and returns whatever
# channels it had, so its failure mode is silent short channels rather than an
# error. Do not re-pin it.
from minimateplus.waveform_codec import _MODES, decode_waveform_v2, is_record
from .models import IdfEvent, IdfPeaks, IdfReport
@@ -89,23 +94,70 @@ _BODY_MAGIC = b"\x00\x02\x00"
# fixed-header region where the same magic legitimately appears inside
# channel-test records and the compliance block (offsets 0x015d, 0x091c,
# 0x0ae2, 0x0d30 in observed events).
_BODY_SCAN_FLOOR = 0x0E00
# Lowered from 0x0E00 to 0x0C00 (2026-09-10). Three-channel events -- mic
# disabled -- have a shorter fixed header and put their record chain head at
# 0x0dba, below the old floor. The head was therefore invisible to the scan,
# which fell through to the *Vert* segment-0 record and decoded a body shifted
# one position around the channel rotation. 46 of 139 files in the
# 9-10-26-csv-req corpus were affected; all 46 became per-sample exact once
# the head was reachable. The floor still skips the fixed-header region,
# where `is_record()` can match channel-test records (0x015d, 0x091c, 0x0ae2).
_BODY_SCAN_FLOOR = 0x0C00
# Geophone count → in/s, derived from sidecar ground truth: the smallest
# non-zero sample in 1,014-file corpus is 0.0003 in/s.
_GEO_LSB_IPS = 0.0003
# Cap on trial decodes per file. Chain-head detection normally yields one
# or two candidates; the cap only bounds the worst case on a corrupt file.
_MAX_BODY_CANDIDATES = 16
# Geophone count → in/s.
#
# The old value 0.0003 was read off the smallest non-zero sample in the
# sidecar corpus, but that sample is Thor's *4-decimal display rounding* of
# the true LSB, not the LSB itself. It read every series-4 geophone sample
# 3.3% low. The quantisation ladder gives it away: counts 1..6 export as
# 0.0003, 0.0006, 0.0009, 0.0012, 0.0016, 0.0019 — an LSB of exactly 0.0003
# would end 0.0015, 0.0018.
#
# The value below maximises exact 4-dp agreement over 1,046,016 paired
# samples (454 channel-events, 2 units) at 99.854%, versus 50.7% for 0.0003.
# It is a global constant, not a per-unit calibration: all 8 UM units in the
# production store independently agree to within ±0.07% on their
# device-reported PPV. 1/LSB = 3222.6 counts per in/s.
#
# The value is pinned, not guessed. Each exported sample constrains the LSB
# to the window that rounds to the printed 4-dp figure; intersecting 991,415
# such constraints (clean channel-events only) gives
#
# LSB in [0.000310307933, 0.000310308057] width 1.2e-10
#
# 0.000310308 sits at the centre of that window. Equivalent full scale is
# 10.0 in/s / 0.000310308 = 32226.05 counts.
#
# Corroboration from the device: an IDFH interval that never recorded keeps
# its min/max accumulator at its ±full-scale seed, and that seed is
# (min=+32226, max=-32226) — the same magnitude, independently. Note the
# tempting closed form 10.0/32226 is very slightly WRONG: it lands 4.5e-10
# above the feasible window and loses 78 boundary samples to the literal
# value while never winning one. Series-3 uses 32000 counts for the same
# 10.0 in/s, so the two generations do NOT share a scale.
#
# Ground truth + harness: scratch/verify_thor_against_csv.py
_GEO_LSB_IPS = 0.000310308
# Microphone count → psi, derived from sidecar regression on 50 sample
# pairs from UM11719_20231219162723.IDFW (mic-heavy event).
_MIC_LSB_PSI = 2.14e-6
# IDFH histogram constants.
_IDFH_INTERVAL_SIZE = 72 # bytes per per-interval record
# Bytes per interval record = 16 per channel + an 8-byte tail, so a
# 4-channel unit uses 72 and a mic-disabled 3-channel unit uses 56. It is
# NOT a constant: derive it per segment from the interval counter (see
# decode_idfh_body). This value survives only as the 4-channel default.
_IDFH_INTERVAL_SIZE = 72 # bytes per per-interval record (4 channels)
_IDFH_CHANNEL_BLOCK = 16 # bytes per channel inside an interval record
_IDFH_INTERVAL_TAIL = 8 # bytes after the per-channel blocks
_IDFH_SEGMENT_HEADER = 10 # bytes: [len_be 2B][0a 00 00 00 4B][00 NN 2B][05 3f 2B]
_IDFH_SEGMENT_TAIL = 2 # bytes after the interval data block, before next marker
_IDFH_HALFP_FREQ_NUM = 512.0 # freq_hz = NUM / halfp; halfp ≤ 5 means ">100 Hz" sentinel
_IDFH_GEO_FULL_SCALE = 10.0 # in/s — Normal range
_IDFH_INT16_FS = 32768.0
_IDFH_CHANNELS = ("Tran", "Vert", "Long", "MicL")
@@ -223,26 +275,67 @@ def _find_waveform_body_offset(buf: bytes) -> Optional[int]:
"""
if len(buf) < _BODY_SCAN_FLOOR + 8:
return None
best: Optional[tuple[int, int]] = None # (total_samples, offset)
i = _BODY_SCAN_FLOOR
while True:
j = buf.find(_BODY_MAGIC, i)
if j < 0:
break
i = j + 1
# 1. Locate every plausible per-channel record header. A header carries
# [len 2B][channel_id][00][00] at +2..+6, so anchor the search on the
# three-byte ``<cid> 00 00`` signature and validate with is_record().
# Scanning candidate *preambles* instead is not viable: MODE_RAW16 is
# ``00 00``, so every run of three zero bytes would look like a body
# start and each would cost a full trial decode (~0.5 s/file measured).
floor = max(0, _BODY_SCAN_FLOOR - 7)
starts: list = []
for cid in (0x46, 0x47, 0x48, 0x49):
sig = bytes((cid, 0x00, 0x00))
i = floor
while True:
j = buf.find(sig, i)
if j < 0:
break
i = j + 1
q = j - 4
if q >= floor and is_record(buf, q):
starts.append(q)
if not starts:
return None
starts.sort()
# 2. A body begins at the head of a record chain -- a record that no other
# record's length field points at. The head's own payload is the
# implicit segment-0 Tran record, and the body offset is head + 7 (past
# [len 2B][cid][00][00][seg]) so that body[1:3] lands on the mode.
ends = {q + 2 + int.from_bytes(buf[q + 2 : q + 4], "big") for q in starts}
heads = [q for q in starts if q not in ends] or starts[:1]
# 3. Trial-decode each head and keep the best. Prefer a candidate where
# all four channels come out the same length: scoring on raw sample
# count alone picks false positives sitting *inside* a record header,
# which decode a plausible-looking but rotation-shifted body that
# silently drops each channel's segment 0.
best = None
best_off = None
for head in heads[:_MAX_BODY_CANDIDATES]:
j = head + 7
if j + 3 > len(buf) or (buf[j + 1], buf[j + 2]) not in _MODES:
continue
try:
decoded = decode_waveform_v2(buf[j:])
except Exception:
continue
if not decoded:
continue
lengths = [len(v) for v in decoded.values() if v]
total = sum(len(v) for v in decoded.values())
# A "real" body has more than just the 2-sample preamble.
if total <= 2:
continue
if best is None or total > best[0]:
best = (total, j)
return best[1] if best else None
# >= 3 rather than == 4: a mic-disabled event has only the three geo
# channels, and demanding four made `equal` permanently False for
# them, leaving the pick to raw sample count alone.
equal = len(lengths) >= 3 and len(set(lengths)) == 1
score = (equal, total)
if best is None or score > best:
best, best_off = score, j
return best_off
def _decode_waveform_samples(buf: bytes) -> Optional[dict]:
@@ -299,6 +392,12 @@ class IdfhInterval:
micl_min: int
micl_max: int
micl_halfp: int
# 4 on a normal unit; 3 when the microphone is disabled, in which case the
# micl_* fields are absent from the record and read as zero.
n_channels: int = 4
def has_channel(self, channel: str) -> bool:
return channel != "MicL" or self.n_channels >= 4
def peak_count(self, channel: str) -> int:
mn = getattr(self, f"{channel.lower()}_min")
@@ -307,7 +406,11 @@ class IdfhInterval:
def peak_ips(self, channel: str) -> float:
"""Convert peak count to in/s (geo channels only)."""
return self.peak_count(channel) / _IDFH_INT16_FS * _IDFH_GEO_FULL_SCALE
# Same geo LSB as the waveform path — verified independently against
# the IDFH exports: as peak magnitude rises (and 4-dp quantisation
# noise falls) the implied LSB converges on 0.0003103, matching
# _GEO_LSB_IPS. The old 10.0/32768 read histogram peaks 1.7% low.
return self.peak_count(channel) * _GEO_LSB_IPS
def freq_hz(self, channel: str) -> Optional[float]:
halfp = getattr(self, f"{channel.lower()}_halfp")
@@ -316,11 +419,46 @@ class IdfhInterval:
return _IDFH_HALFP_FREQ_NUM / halfp
def _decode_idfh_interval(buf72: bytes, offset: int) -> IdfhInterval:
"""Decode one 72-byte interval record into per-channel min/max/halfp."""
def _is_unwritten_interval(interval: "IdfhInterval") -> bool:
"""True for an interval slot the device reserved but never wrote.
Thor seeds each interval's per-channel accumulators at ``min = +full
scale`` and ``max = -full scale`` and then narrows them as samples
arrive. A slot that never recorded keeps that seed, so ``min > max`` —
impossible for real data. Such a record decodes to a full-scale
10.0 in/s peak on every channel and, being a max-over-intervals, poisons
the whole file's PPV.
Rare but real: exactly 1 of 497,611 corpus intervals, and it inflated
that file's Long PPV from 0.0081 to 10.0 in/s. The inversion is always
all-or-nothing across channels (0 partial cases in the corpus), so
requiring every channel to be inverted keeps this from ever firing on
genuine data.
"""
pairs = [
(interval.tran_min, interval.tran_max),
(interval.vert_min, interval.vert_max),
(interval.long_min, interval.long_max),
]
if interval.has_channel("MicL"):
pairs.append((interval.micl_min, interval.micl_max))
return all(mn > mx for mn, mx in pairs)
def _decode_idfh_interval(buf72: bytes, offset: int,
n_channels: int = 4) -> IdfhInterval:
"""Decode one interval record into per-channel min/max/halfp.
The record is ``n_channels`` × 16-byte blocks plus an 8-byte tail, so it
is 72 bytes on a normal unit and 56 when the microphone is disabled.
Missing channels read as zero.
"""
import struct
fields = []
for i in range(4):
if i >= n_channels:
fields.extend([0, 0, 0])
continue
block = buf72[i * 16 : (i + 1) * 16]
mn = struct.unpack_from(">h", block, 0)[0]
mx = struct.unpack_from(">h", block, 2)[0]
@@ -336,6 +474,7 @@ def _decode_idfh_interval(buf72: bytes, offset: int) -> IdfhInterval:
vert_min=fields[3], vert_max=fields[4], vert_halfp=fields[5],
long_min=fields[6], long_max=fields[7], long_halfp=fields[8],
micl_min=fields[9], micl_max=fields[10], micl_halfp=fields[11],
n_channels=n_channels,
)
@@ -343,36 +482,73 @@ def decode_idfh_body(buf: bytes) -> list:
"""Walk an IDFH file and decode every interval record.
The body has one or more segments; each segment header is 12 bytes:
``[length_be 2B][0a 00 00 00][00 NN_counter][05 3f]`` where ``length``
``[length_be 2B][0a 00 00 00][counter_be 2B][05 3f]`` where ``length``
is bytes from the magic through the end of the interval block
(= 10 + 72 × n_intervals). Segments are separated by a 2-byte tail
+ next-segment 2-byte prefix (the bytes before the next length field).
Confirmed against the 859-file corpus (181,071 intervals decoded; 1
failure is the sig-B BE9439 file).
``counter`` is a **uint16 BE cumulative interval index** — the 0-based
index of the LAST interval in this segment. Segments carry 10
intervals each, so it runs 9, 19, 29, ... across the file.
⚠ This validator used to require ``buf[j + 4] == 0x00``, i.e. that the
counter's high byte was zero. That silently capped every histogram at
**250 intervals**: the moment the cumulative counter passed 255 the high
byte went non-zero and every later segment was rejected, so any
monitoring run longer than ~4 hours lost its tail — frequently the part
holding the event peak, which is why those files' PPV read low. 540 of
858 corpus files were affected. Do not reinstate that check.
"""
intervals: list = []
i = 0
prev_counter = -1 # so the first segment's n = counter + 1
while True:
j = buf.find(b"\x0a\x00\x00\x00", i)
if j < 0 or j < 2:
break
# Validate: [length_be][0a 00 00 00][00 NN][05 3f]
if buf[j + 4] != 0x00 or buf[j + 6 : j + 8] != b"\x05\x3f":
# Validate: [length_be][0a 00 00 00][counter_be][05 3f]. The counter
# is deliberately NOT constrained — see the note above.
if buf[j + 6 : j + 8] != b"\x05\x3f":
i = j + 1
continue
length = int.from_bytes(buf[j - 2 : j], "big")
n = (length - _IDFH_SEGMENT_HEADER) // _IDFH_INTERVAL_SIZE
counter = int.from_bytes(buf[j + 4 : j + 6], "big")
header_start = j - 2
if length < _IDFH_SEGMENT_HEADER or header_start + length > len(buf):
# Truncated / bogus length — not a real segment header.
i = j + 1
continue
# The counter is the cumulative index of this segment's LAST interval,
# so the interval count is its delta from the previous segment. That
# gives the record stride, which is NOT fixed: 16 bytes per channel
# plus an 8-byte tail, so 72 for a 4-channel unit and 56 for a
# mic-disabled 3-channel one. Assuming 72 unconditionally made every
# 3-channel histogram read 7 intervals per 10-interval segment,
# walking off alignment into garbage that decoded as ~10 in/s peaks.
n = counter - prev_counter
if n <= 0:
i = j + 1
continue
header_start = j - 2
stride = (length - _IDFH_SEGMENT_HEADER) // n
n_channels, remainder = divmod(stride - _IDFH_INTERVAL_TAIL,
_IDFH_CHANNEL_BLOCK)
if remainder or not (1 <= n_channels <= 4):
i = j + 1
continue
interval_start = header_start + _IDFH_SEGMENT_HEADER
for k in range(n):
off = interval_start + k * _IDFH_INTERVAL_SIZE
if off + _IDFH_INTERVAL_SIZE > len(buf):
off = interval_start + k * stride
if off + stride > len(buf):
break
chunk = buf[off : off + _IDFH_INTERVAL_SIZE]
intervals.append(_decode_idfh_interval(chunk, off))
chunk = buf[off : off + stride]
interval = _decode_idfh_interval(chunk, off, n_channels)
if _is_unwritten_interval(interval):
# Reserved-but-never-recorded slot: the min/max accumulators
# still hold their ±full-scale seed. Counting it would
# fabricate a 10.0 in/s peak on every channel.
continue
intervals.append(interval)
prev_counter = counter
# Advance past this segment + the 2-byte tail.
i = header_start + length + _IDFH_SEGMENT_TAIL
return intervals
@@ -452,7 +628,12 @@ def read_idf_file(
peak_long = max((iv.peak_ips("Long") for iv in intervals), default=0.0)
# Mic peak in psi — Thor stores per-interval mic ADC counts in the
# binary; convert the max count to psi via the per-count factor.
mic_peak_count = max((iv.peak_count("MicL") for iv in intervals), default=0)
# Skip on a mic-disabled (3-channel) unit: those records carry no mic
# block at all, so peak_count("MicL") would report a synthetic zero.
mic_peak_count = max(
(iv.peak_count("MicL") for iv in intervals if iv.has_channel("MicL")),
default=0,
)
mic_peak_psi = mic_count_to_psi(mic_peak_count) if mic_peak_count else None
rep = IdfReport(
serial_number=md.serial,
+239
View File
@@ -22,6 +22,7 @@ shrink or disappear.
from __future__ import annotations
import datetime
import math
from dataclasses import dataclass, field
from typing import Any, Dict, Optional, Tuple
@@ -154,6 +155,14 @@ class IdfReport:
)
@dataclass(frozen=True)
class MicromateRunState:
"""`SUB 0x49` content[0]. 0x00 idle, 0x02 monitoring, 0x03 calling home
(ten of ten in the 10-14 ACH session); anything else is named, not guessed."""
code: int
name: str
# ── IdfPeaks / IdfProjectInfo / IdfSensorCheck (narrow grouping types) ───────
@@ -396,3 +405,233 @@ class IdfEvent:
)
ev._waveform_key = waveform_key
return ev
# ── Live-device models (2026-09-27) ───────────────────────────────────────────
#
# These describe what a unit reports over the wire, not what Thor wrote to a
# file. Everything above this line came out of Thor's exports; everything below
# came out of Thor's *traffic*. Field offsets are recorded in
# ``micromate/client.py`` next to the code that reads them.
@dataclass
class MicromateDeviceInfo:
"""Identity gathered by ``MicromateClient.connect()``.
Sourced from three reads:
``0x5B`` POLL → manufacturer, model
``0x15`` SERIAL → serial
``0x49`` STATE → monitoring
plus ``firmware_line``, which comes free from the flags byte of any
response and needs no read of its own.
"""
serial: str
manufacturer: Optional[str] = None # "Instantel"
model: Optional[str] = None # "MM/ISEE/S/IO" (CB) / "MM/ISEE/S" (BD)
firmware_line: Optional[str] = None # "blastware" | "thor" | "unknown"
monitoring: Optional[bool] = None
active_setup: Optional[str] = None # e.g. "TEST1.mmb"
def __str__(self) -> str:
bits = [self.serial]
if self.model:
bits.append(self.model)
if self.firmware_line:
bits.append(f"{self.firmware_line} fw")
if self.monitoring is not None:
bits.append("MONITORING" if self.monitoring else "idle")
if self.active_setup:
bits.append(f"setup={self.active_setup}")
return " ".join(bits)
@dataclass
class MicromateState:
"""A unit's live state, from ``SUB 0x1C``.
``device_time`` is the unit's own clock, in its own local timezone — it is
NOT converted. Nothing else this protocol exposes reports the unit's time,
which makes it the only way to detect a drifted clock before it lands in
event timestamps.
"""
monitoring: bool
device_time: Optional[datetime.datetime] = None
battery_volts: Optional[float] = None
memory_total_bytes: Optional[int] = None
memory_free_bytes: Optional[int] = None
raw: Optional[bytes] = field(default=None, repr=False)
@property
def memory_used_bytes(self) -> Optional[int]:
if self.memory_total_bytes is None or self.memory_free_bytes is None:
return None
return self.memory_total_bytes - self.memory_free_bytes
@property
def memory_used_fraction(self) -> Optional[float]:
used = self.memory_used_bytes
if used is None or not self.memory_total_bytes:
return None
return used / self.memory_total_bytes
def __str__(self) -> str:
bits = ["MONITORING" if self.monitoring else "idle"]
if self.device_time:
bits.append(self.device_time.strftime("%Y-%m-%d %H:%M:%S"))
if self.battery_volts is not None:
bits.append(f"{self.battery_volts:.2f} V")
frac = self.memory_used_fraction
if frac is not None:
bits.append(f"memory {frac * 100:.1f}% used")
return " ".join(bits)
_RECORD_MODES = {0x01: "Waveform", 0x02: "Waveform Manual", 0x03: "Histogram", 0x04: "Histogram Combo"}
# The unit's OWN conversion constants, identified bit-exactly from what it
# stored for keypad entries (2026-10-19). Not the textbook 3.28084 / 2.20462:
# convert back with these, or 45 lb entered on the unit reads as 44.89 lb.
_FT_PER_M = 3.2808
_LB_PER_KG = 2.21
_PA_PER_PSI = 6894.757
_P_REF_PA = 20e-6 # dB re 20 µPa
@dataclass
class MicromateSetup:
"""A unit's active setup, from ``SUB 0x1A`` — see ``micromate/setup_block.py``.
**Measured fields only.** Each was located by changing that one setting on a
unit's keypad and watching the bytes; anything graded inferred or unknown in
the protocol reference is left in ``raw`` rather than guessed at here.
⚠ This is what the unit is set to *right now* — including unsaved edits if
someone is in its setup menu, because ``0x1A`` reads the keypad's edit
buffer. Values are in the units the unit stores, whatever it displays:
in/s, psi, metres, kilograms.
"""
name: str # ⚠ ".MMB" after a keypad save, ".mmb" after a load
record_mode: int # see record_mode_name
sample_rate: int # samples per second
histogram_interval_s: int
pretrigger_s: float # positive; the unit stores it negative
auto_record_stop: bool # False = Fixed record time
record_time_s: float
auto_stop_after_s: int # quiet time before an Auto stop
geophones_active: bool
mic_active: bool
trigger_on_geophones: bool
trigger_on_mic: bool
geo_trigger_ips: Tuple[float, float, float] # Tran, Vert, Long
mic_type: str # "linear" | "sound_level" | "unknown (<code>)"
mic_trigger_psi: Optional[float] # linear mic only; SLM units not measured
job_number_enabled: bool
job_number: int # kept while switched off
scaled_distance_enabled: bool
distance_m: float
charge_weight_kg: float
notes: Dict[str, str] # label -> value, in the unit's order
raw: bytes = field(default=b"", repr=False) # the 2,092-byte content
@property
def record_mode_name(self) -> str:
return _RECORD_MODES.get(self.record_mode, f"unknown (0x{self.record_mode:02x})")
@property
def mic_trigger_db(self) -> Optional[float]:
"""dB re 20 µPa. Matches the unit's screen to ±0.001 dB on 131 and 140."""
if not self.mic_trigger_psi:
return None
return 20.0 * math.log10(self.mic_trigger_psi * _PA_PER_PSI / _P_REF_PA)
@property
def distance_ft(self) -> float:
return self.distance_m * _FT_PER_M
@property
def charge_weight_lb(self) -> float:
return self.charge_weight_kg * _LB_PER_KG
@property
def scaled_distance(self) -> Optional[float]:
"""ft / √lb, as the unit computes it for display. It is not stored."""
if self.charge_weight_kg <= 0:
return None
return self.distance_ft / math.sqrt(self.charge_weight_lb)
@dataclass
class MicromateEventRef:
"""One entry in a unit's event chain, from `1E`/`1F` and optionally `0x0C`.
⚠ **`key` is NOT unique across units.** The event counter starts from the
same value on every Micromate — UM12947 and UM20147 both have an event
`055d4a81`, with different sizes and different contents. Use `uid`, or key
on `(serial, key_hex)`, for anything that stores or deduplicates. A store
keyed on the event key alone silently treats one unit's event as a duplicate
of another's, and nothing raises.
"""
index: int
key: bytes # 4-byte event key from the chain walk
size: int # bytes the device will send for this event
serial: Optional[str] = None # the unit, because `key` alone is ambiguous
# From `SUB 0x0C` — one extra round trip per event, so optional.
record_type: Optional[str] = None # "waveform" | "histogram"
timestamp: Optional[datetime.datetime] = None
setup: Optional[str] = None # setup file name, no extension
sensor_location: Optional[str] = None
peak_vector_sum_ips: Optional[float] = None # per-sample PVS, device-computed
peaks_ips: Optional[Dict[str, float]] = None # {"Tran": …, "Vert": …, …}
raw_record: Optional[bytes] = field(default=None, repr=False)
@property
def key_hex(self) -> str:
return self.key.hex()
@property
def uid(self) -> str:
"""`SERIAL:key` — safe to use as a primary key. See the class note."""
return f"{self.serial or '?'}:{self.key_hex}"
@property
def is_histogram(self) -> Optional[bool]:
if self.record_type is None:
return None
return self.record_type == "histogram"
@property
def suffix(self) -> Optional[str]:
return {"waveform": ".IDFW", "histogram": ".IDFH"}.get(self.record_type or "")
@property
def filename(self) -> Optional[str]:
"""The name THOR would have given this event.
`<serial>_<YYYYMMDDHHMMSS>.IDF{W,H}` — e.g.
`UM12947_20260923163319.IDFW`. Verified against the production store
for all five bench events.
⚠ The type comes from the **protocol**, not the payload, so it has to be
carried here from the `0x0C` read. Returns None without it: guessing
the suffix would file a histogram as a waveform, and `read_idf_file()`
dispatches on exactly that.
"""
if not (self.serial and self.timestamp and self.suffix):
return None
return f"{self.serial}_{self.timestamp:%Y%m%d%H%M%S}{self.suffix}"
def __str__(self) -> str:
bits = [self.uid, f"{self.size} B"]
if self.record_type:
bits.append(self.record_type)
if self.timestamp:
bits.append(self.timestamp.strftime("%Y-%m-%d %H:%M:%S"))
if self.peak_vector_sum_ips is not None:
bits.append(f"PVS {self.peak_vector_sum_ips:.4f} in/s")
return " ".join(bits)
+113
View File
@@ -0,0 +1,113 @@
"""Micromate (Series IV) opcode table: which SUBs write, and which collide.
One place, as the parity spec requires. The gate is an ALLOWLIST: a SUB is
transmitted only if it is a catalogued read (READ_SUBS) or a catalogued write
that arrives through `MicromateProtocol.execute` (one call's permission, capped at
ENABLEABLE_WRITES; the connection itself holds none). An unknown SUB is refused -- clock-set
and delete-all have Series-IV opcodes nobody has catalogued yet, and "unknown
means read" is the wrong default. `MicromateProtocol._send` consults it
on every outgoing frame, so a write cannot reach a unit by a path nobody
thought about -- a scratch tool calling `protocol._send`, a hand-built frame, a
method added later.
Every SUB here was seen as a host->unit request in THOR's captures
(`docs/micromate_protocol_reference.md`). The table classifies REQUESTS: a few
of these values are also ACK SUBs of other commands (0x71 acks 0x8E, 0x72 acks
0x8D), which is irrelevant to a send-side check.
"""
from __future__ import annotations
from types import MappingProxyType
from typing import Dict, FrozenSet, Mapping
_WRITE_SUBS: Dict[int, str] = {
0x47: "scheduler enable/disable",
0x68: "setup push: preferences block (0x08)",
0x71: "setup push: setup block (0x1A)",
0x72: "setup push: setup confirm",
0x73: "setup push: preferences confirm",
0x7E: "call-home config write (0x2C)",
0x7F: "call-home config confirm",
0x82: "setup push: trigger block (0x2E)",
0x83: "setup push: trigger confirm",
0x8D: "file open for write",
0x8E: "file body write",
0x96: "start monitoring",
0x97: "stop monitoring",
0xA2: "end call-home",
0xA8: "delete one event",
0xAA: "delete-event confirm",
0xDA: "setup push: file name",
}
# Same SUB, opposite consequence on the other series (not the same bytes:
# Series III's CONFIRM ERASE carries offset 0x0000 and token 0xFE, THOR's 0xA2
# carries offset 0xFFFF). Never transmitted on
# Series IV, allowed or not: if a Series-III unit is at the address (a moved
# modem, a stale IP), it would execute the other meaning. Lifting an entry is
# a spec change, not a parameter.
_CROSS_SERIES_COLLISIONS: Dict[int, str] = {
0xA2: "CONFIRM ERASE on Series III -- erases every stored event; "
"'end call-home' on Series IV",
}
_READ_SUBS: Dict[int, str] = {
0x01: "device info",
0x06: "storage range",
0x08: "event index / preferences block",
0x0A: "monitor log",
0x0C: "event record",
0x15: "serial number",
0x1A: "setup block",
0x1C: "monitor status",
0x1E: "event first",
0x1F: "event next",
0x2C: "call-home config",
0x2E: "trigger config",
0x3F: "setup list first",
0x40: "setup list next",
0x41: "active setup",
0x48: "file read next page",
0x49: "state",
0x5A: "bulk download",
0x5B: "poll",
0x93: "arm event",
0x94: "file open for read",
}
# Read-only views: a stray .pop() anywhere in the process cannot disable a gate.
WRITE_SUBS: Mapping[int, str] = MappingProxyType(_WRITE_SUBS)
CROSS_SERIES_COLLISIONS: Mapping[int, str] = MappingProxyType(_CROSS_SERIES_COLLISIONS)
READ_SUBS: Mapping[int, str] = MappingProxyType(_READ_SUBS)
# The write SUBs any code may transmit at all -- through MicromateProtocol.execute,
# one call at a time. Raising this is a spec change, reviewed like one: delete
# (0xA8/0xAA), raw file writes (0x8D/0x8E -- they could reach the modem
# settings) and 0xA2 never belong here without one.
ENABLEABLE_WRITES = frozenset({0x96, 0x97})
class OpcodeRefused(RuntimeError):
"""A frame was stopped before it reached the wire."""
def check_transmit(sub: int, allowed_writes: FrozenSet[int] = frozenset()) -> None:
"""Raise OpcodeRefused unless `sub` may go on the wire.
Precedence: (1) a cross-series collision is refused always; (2) a
SUB in neither READ_SUBS nor WRITE_SUBS is unknown and refused whatever
`allowed_writes` says; (3) a catalogued write is refused unless in
`allowed_writes`.
"""
if sub in CROSS_SERIES_COLLISIONS:
raise OpcodeRefused(
f"refused to transmit SUB 0x{sub:02X}: {CROSS_SERIES_COLLISIONS[sub]}")
if sub not in READ_SUBS and sub not in WRITE_SUBS:
raise OpcodeRefused(
f"refused to transmit SUB 0x{sub:02X}: unknown opcode -- not in "
"micromate.opcodes; catalogue it first (allowing it does not help)")
if sub in WRITE_SUBS and sub not in allowed_writes:
raise OpcodeRefused(
f"refused to transmit SUB 0x{sub:02X} ({WRITE_SUBS[sub]}): writes are "
"not enabled on this connection")
+635
View File
@@ -0,0 +1,635 @@
"""
protocol.py — one method per Micromate (Series IV) wire command.
Returns raw payload bytes. Interpretation belongs in ``client.py``; this layer
knows frames, offsets and sequencing, and nothing about what a field means.
Scope: **reads, plus start/stop monitoring through `execute()` only --
enforced** (in this package: the Series-3 `minimateplus` stack and raw-socket
bench bridges are outside the gate). Every outgoing frame passes
`micromate.opcodes.check_transmit()` in `_send`: a write opcode is refused
unless it arrives through `execute()` (the connection itself holds no write
permission), `execute()` can permit only SUBs under `ENABLEABLE_WRITES`
(`0x96` / `0x97`), and `0xA2` -- CONFIRM ERASE on Series III -- is refused
always. The one caller of `execute()` is SFM's change path,
`sfm/device_access/s4.py` (a test pins that). The gate is an allowlist: a SUB
not catalogued in `opcodes` (read or write) is refused as unknown. No command
has ever been originated against a unit by this project; every write in ``docs/micromate_protocol_reference.md`` was performed
by THOR while we recorded. The first thing this codebase ever sends to a
customer's instrument should be a decision someone made on purpose, not a side
effect of a client that grew a method. Write frames are *built* in
``micromate.writes`` as reviewable plans; building one sends nothing.
``execute(plan)`` is the only write path: one call's permission, at most
``ENABLEABLE_WRITES``, and only on a connection that has had Micromate-flagged
replies.
Every offset and params layout below was read off THOR's own frames in
``bridges/captures/9-24-26 - micromate2/`` rather than taken from the spec
table, because the same exercise during the framing work found three of that
table's rules wrong. It found three more here:
* ``0x0A`` is the **monitor-log walk** — the same request repeated, the
device advancing its own cursor, terminated by a short response — not the
keyed "event header, 30 B list record" the spec describes.
* ``0x1E``/``0x1F`` carry **token 0xFE** at ``params[7]``. The protocol
reference documents all-zero params for the browse walk; that was our own
probing, and THOR does not do it that way.
* There is **no fixed preamble**. Sessions open with ``POLL`` and go
straight to the operation. ``POLL → SERIAL → 0x49 → POLL`` appears in 3 of
8 captured sessions and is THOR's *connection check*, not a handshake.
And one useful negative: **no ``SESSION_RESET`` (``41 03``).** Series III
needs that 2-byte signal to wake a monitoring unit or it will not answer POLL
over TCP. THOR never sends it — 0 occurrences across all 8 sessions, including
40 frames exchanged with a unit that *was* monitoring.
"""
from __future__ import annotations
import logging
import math
import struct
import time
from typing import TYPE_CHECKING, Optional
from minimateplus.transport import BaseTransport
from .framing import (
FLAGS_BLASTWARE, FLAGS_THOR, MicromateFrame, MicromateFrameParser,
build_request, request_sub,
)
from .opcodes import ENABLEABLE_WRITES, OpcodeRefused, check_transmit
if TYPE_CHECKING:
from .writes import WritePlan
log = logging.getLogger(__name__)
DEFAULT_RECV_TIMEOUT = 10.0
# An acknowledgement carries an 11-byte data section and nothing else. It is
# also how the monitor-log walk says "no more records".
ACK_DATA_LEN = 11
# ── Command SUBs ──────────────────────────────────────────────────────────────
SUB_DEVICE_INFO = 0x01
SUB_STORAGE_RANGE = 0x06
SUB_EVENT_INDEX = 0x08
SUB_MONITOR_LOG = 0x0A
SUB_EVENT_RECORD = 0x0C
SUB_SERIAL = 0x15
SUB_COMPLIANCE_CONFIG = 0x1A
SUB_MONITOR_STATUS = 0x1C
SUB_EVENT_FIRST = 0x1E
SUB_EVENT_NEXT = 0x1F
SUB_CALL_HOME_CONFIG = 0x2C
SUB_TRIGGER_CONFIG = 0x2E
SUB_SETUP_FIRST = 0x3F
SUB_SETUP_NEXT = 0x40
SUB_SETUP_ACTIVE = 0x41
SUB_STATE = 0x49
SUB_BULK_DOWNLOAD = 0x5A
SUB_POLL = 0x5B
SUB_ARM_EVENT = 0x93
# ⚠ Reads are SINGLE-STEP. Series III probes at offset 0 to learn the length,
# then reads again at that length; a Micromate returns the whole block when
# asked for 0xFFFF. THOR never probes, which is why `MicromateFrame.probe_length`
# reads 0 on live traffic.
READ_ALL = 0xFFFF
# The two commands that do NOT use READ_ALL, and the data length each returned
# on UM12947 (firmware 11.0CB).
_OFFSETS = {
SUB_POLL: 0x0030, # 59 B — the one offset THOR treats as a constant
SUB_SERIAL: 0x000A, # 21 B
}
# Data-section lengths observed, for orientation only — deliberately NOT
# asserted. `SUB 0x1C` is 4 bytes longer on the Thor firmware line (0x30 vs
# 0x2C declared), so a length check here would fire spuriously on half the
# fleet. See the protocol reference, "A/B: Blastware build vs Thor build".
OBSERVED_DATA_LEN = {
SUB_STORAGE_RANGE: 47, SUB_EVENT_INDEX: 101, SUB_MONITOR_LOG: 297,
SUB_EVENT_RECORD: 221, SUB_SERIAL: 21, SUB_COMPLIANCE_CONFIG: 2103,
SUB_MONITOR_STATUS: 55, SUB_EVENT_FIRST: 19, SUB_EVENT_NEXT: 19,
SUB_CALL_HOME_CONFIG: 137, SUB_TRIGGER_CONFIG: 39,
SUB_SETUP_FIRST: 266, SUB_SETUP_NEXT: 266, SUB_SETUP_ACTIVE: 266,
SUB_STATE: 16, SUB_POLL: 59, SUB_ARM_EVENT: ACK_DATA_LEN,
}
# `1E`/`1F` carry this at params[7]. Series III uses the same value to arm its
# bulk stream; here THOR sends it on every chain read, browse or download.
EVENT_TOKEN = 0xFE
# `SUB 0x5A` request size, in bytes of file payload per response.
#
# ⚠ **16,384, not THOR's 1024.** Measured on UM20147 (2026-10-02): requests of
# 1024 / 2048 / 4096 / 8192 / 16384 all returned byte-identical data against a
# known-good download, and anything larger is **silently clamped to 16,384** —
# correct bytes, short length, no error.
#
# ⚠ The win is real but MODEST, and smaller than a first reading suggests.
# Measured over an RX55, cost per request is ~0.21 s + bytes/2350 — so a download
# is throughput-bound, not round-trip bound. A 72,560-byte event costs ~46 s at
# THOR's 1024 B and ~32 s at 16,384 B: a **30% saving**, not 14x, because ~31 s of
# it is bytes on the wire and no amount of batching addresses that.
#
# Still worth having: 30% faster, and 14x fewer requests is 14x fewer chances for
# a link to drop mid-download.
#
# ⚠ Measured on ONE unit, over USB. The loop below is driven by bytes received
# rather than chunk index, so a unit that clamps lower simply takes more
# requests instead of failing — which is what makes raising this safe.
CHUNK_SIZE = 16384
# THOR's value. Pass `chunk_size=THOR_CHUNK_SIZE` to reproduce its wire traffic
# exactly; the replay test does.
THOR_CHUNK_SIZE = 1024
# Every `0x5A` response prefixes the file bytes with 11 bytes of header.
_CHUNK_PREFIX = 11
# ── Exceptions ────────────────────────────────────────────────────────────────
class ProtocolError(Exception):
"""The device violated the expected protocol."""
class TimeoutError(ProtocolError):
"""No response arrived within the allowed time."""
class ChecksumError(ProtocolError):
"""A received frame failed its checksum."""
class UnexpectedResponse(ProtocolError):
"""The response SUB did not match the request."""
class ShortRead(ProtocolError):
"""A bulk download returned fewer bytes than the device promised."""
# ── Params builders ───────────────────────────────────────────────────────────
def token_params(token: int = EVENT_TOKEN) -> bytes:
"""`1E`/`1F`: the token sits at params[7]."""
return bytes(7) + bytes([token]) + bytes(2)
def key_params(key4: bytes) -> bytes:
"""`0x0C`: the full 4-byte event key at params[4:8]."""
if len(key4) != 4:
raise ValueError(f"key4 must be 4 bytes, got {len(key4)}")
return bytes(4) + key4 + bytes(2)
def key_lo_params(key4: bytes) -> bytes:
"""`0x0A`: only the key's **low two bytes**, at params[6:8].
⚠ Inferred from a single key value. All nine captured `0x0A` frames carry
`4a 81`, and the event key in play was `055d4a81` — so this is consistent
with "the low half of the current key" and equally consistent with "a
cursor handle that happened to equal it". Both readings produce the same
bytes for that key, so one event cannot separate them.
It does not matter much in practice: the walk works with the same params
repeated, so whichever it is, passing the current key is right.
"""
if len(key4) != 4:
raise ValueError(f"key4 must be 4 bytes, got {len(key4)}")
return bytes(6) + key4[2:4] + bytes(2)
def chunk_params(key4: bytes, byte_offset: int) -> bytes:
"""`0x5A`: the key opens the file, then a byte offset walks it.
Chunk 0 carries the event key at params[0:4] — that is what says "from the
beginning". Later chunks carry the byte offset **in that same 4-byte slot**,
as a uint32 BE.
⚠ **Written as a uint32 deliberately, and this matters above 64 KB.** Every
offset THOR was observed to send fits in two bytes — the largest was `0x3400`
(13,312) — so `params[0:2]` was always `00 00` and the field looks like a
uint16 at `params[2:4]`. Reading it that way caps a download at **65,536
bytes**, and UM20147 currently holds a **72,560-byte** event, so that cap is
not hypothetical.
A uint32 here is **byte-identical for every offset below 65,536**, so it
changes nothing that was verified against THOR's frames (the replay test
asserts all 74 of them) and extends the range to 4 GB.
✅ **Confirmed on hardware 2026-10-01.** UM20147's 72,560-byte event
downloaded in **71 chunks** at the exact promised size, which exercises the
carry into `params[1]` on chunks 64–70. It was inference for one commit and
is now evidence.
⚠ This is the **Series III 64 KB page-boundary bug in a new guise** — there,
`parse_strt_end_offset()` discards the key's page byte and the `5A` walk
crashed once a unit's buffer crossed 64 KB (fixed 2026-10-26: a Blastware
recording showed its 5A address is a plain 32-bit linear one, like this).
The lesson that transfers: an address field whose high bytes are zero
in every capture is not a narrow field, it is an untested one.
"""
if byte_offset == 0:
if len(key4) != 4:
raise ValueError(f"key4 must be 4 bytes, got {len(key4)}")
return key4 + bytes(6)
if not 0 <= byte_offset <= 0xFFFFFFFF:
raise ValueError(f"byte_offset must fit in uint32, got {byte_offset}")
return struct.pack(">I", byte_offset) + bytes(6)
# ── Protocol ──────────────────────────────────────────────────────────────────
class MicromateProtocol:
"""Wire-level command set for one open connection to a Micromate.
Does not own the transport; lifetime belongs to the client.
proto = MicromateProtocol(transport)
proto.poll()
serial = proto.read_serial()
"""
def __init__(
self,
transport: BaseTransport,
recv_timeout: float = DEFAULT_RECV_TIMEOUT,
strict_checksums: bool = True,
) -> None:
"""
Args:
strict_checksums: raise on a bad checksum. **Defaults to True,
unlike the Series III sibling**, which logs and continues
because its parser cannot reliably tell an inner-frame
delimiter from a checksum byte. That excuse does not apply
here: the Micromate rule is plain SUM8 over the de-stuffed
payload and it holds on 251 of 251 captured frames, so a
mismatch means something real — line noise, a desync, or a rule
we have wrong — and all three are worth hearing about.
The lenient Series III default is instructive: it hid the fact
that the documented checksum rule was wrong for two days. Set
False only to get a field diagnosis unstuck.
"""
self._transport = transport
self._recv_timeout = recv_timeout
self._strict = strict_checksums
self._parser = MicromateFrameParser()
self._pending: list[MicromateFrame] = []
self.last_flags: Optional[int] = None
# ── Identity and state ────────────────────────────────────────────────────
def poll(self) -> MicromateFrame:
"""`0x5B` → `0xA4`. Handshake; carries the ID block and model string.
Every captured session opens with this and nothing before it.
"""
return self._exchange(SUB_POLL)
def read_serial(self) -> bytes:
"""`0x15` → `0xEA`. ASCII, null-terminated — e.g. `UM12947`."""
return self._read(SUB_SERIAL)
def read_device_info(self) -> bytes:
"""`0x01` → `0xFE`. Firmware, calibration, per-channel float block.
⚠ THOR never sends this in any captured session, so the `0xFFFF` offset
is from our own 2026-09-23 probes rather than from THOR's behaviour. It
answered correctly on both firmware lines, but it is the one read here
with no THOR frame behind it.
"""
return self._read(SUB_DEVICE_INFO)
def read_state(self) -> bytes:
"""`0x49` → `0xB6`. A cheap state check; 16 B of data.
`data[11]` (content[0]) is the run state. Measured: `0x00` idle,
`0x02` monitoring (every monitoring sample so far), and `0x03` while
calling home (ten reads of ten in the captured 2026-10-14 ACH
session). No other value has been seen.
`MicromateClient.read_run_state` matches those three exactly and names
anything else `unknown(0x..)`, which the change path refuses;
`connect()`'s `monitoring` tests non-zero, so `0x03` reads True there.
⚠ `0x0E` and `0x0C` (both read while monitoring, so "test for
non-zero") belong to `SUB 0x1C` `data[12]`, a separate field -- not to
this byte. See the reference's `0x49` and `0x1C` sections.
"""
return self._read(SUB_STATE)
def read_monitor_status(self) -> bytes:
"""`0x1C` → `0xE3`. Flag, **device clock**, battery, memory.
⚠ Parse **forward** from the declared length, never backward from the
end. This block is 4 bytes longer on the Thor firmware line, and Series
III's relative-to-end offsets yield a battery voltage of 577.92 V on a
`11.0BD` unit.
"""
return self._read(SUB_MONITOR_STATUS)
def read_storage_range(self) -> bytes:
"""`0x06` → `0xF9`. Event storage extent; 47 B."""
return self._read(SUB_STORAGE_RANGE)
def read_event_index(self) -> bytes:
"""`0x08` → `0xF7`. 101 B. Contents not yet mapped."""
return self._read(SUB_EVENT_INDEX)
def read_trigger_config(self) -> bytes:
"""`0x2E` → `0xD1`. 39 B. Series IV only; no Series III equivalent."""
return self._read(SUB_TRIGGER_CONFIG)
def read_compliance_config(self) -> bytes:
"""`0x1A` → `0xE5`. The whole active setup — 2103 B on UM12947.
One response. Series III needs a 4-frame sequence for the same thing.
"""
return self._read(SUB_COMPLIANCE_CONFIG)
def read_call_home_config(self) -> bytes:
"""`0x2C` → `0xD3`. 137 B — Series III's is 124, so do not reuse its map."""
return self._read(SUB_CALL_HOME_CONFIG)
# ── Setups ────────────────────────────────────────────────────────────────
def read_active_setup_name(self) -> bytes:
"""`0x41` → `0xBE`. 266 B; carries the active `.MMB` name."""
return self._read(SUB_SETUP_ACTIVE)
def read_first_setup(self) -> bytes:
"""`0x3F` → `0xC0`. Head of the setup-file list."""
return self._read(SUB_SETUP_FIRST)
def read_next_setup(self) -> bytes:
"""`0x40` → `0xBF`. Repeat until the record carries an empty name.
Stateful: the device holds the cursor, so the same request walks the
list. 22 of these appear back to back in one captured session.
"""
return self._read(SUB_SETUP_NEXT)
# ── Event chain ───────────────────────────────────────────────────────────
def arm_event(self) -> MicromateFrame:
"""`0x93` → `0x6C`. THOR sends this before **every** `1E`/`1F`.
It replaces Series III's `1E(token=0xFE)` arming step. No params, no
offset payload — an 11-byte ack.
⚠ Whether a unit actually requires it is untested. Do it because it is
known-good, not because it is known-necessary.
"""
return self._exchange(SUB_ARM_EVENT, offset=READ_ALL)
def read_event_first(self) -> bytes:
"""`0x1E` → `0xE1`. First event key + size; 19 B."""
return self._read(SUB_EVENT_FIRST, params=token_params())
def read_event_next(self) -> bytes:
"""`0x1F` → `0xE0`. Next key + size, or the all-zero null sentinel."""
return self._read(SUB_EVENT_NEXT, params=token_params())
def read_event_record(self, key4: bytes) -> bytes:
"""`0x0C` → `0xF3`. 221 B — project, client, operator, timestamp, peaks.
⚠ The peak float in here runs 2–5% above `max(T,V,L)` and is **not** the
vector sum; its offset was inferred, not established. Prefer decoded
samples.
"""
return self._read(SUB_EVENT_RECORD, params=key_params(key4))
def read_monitor_log_next(self, key4: bytes) -> Optional[bytes]:
"""`0x0A` → `0xF5`. One monitor-log record, or None at end of list.
⚠ Not the keyed single read the spec describes. This is a **walk**:
the same request repeated, the device advancing its own cursor, each
response a 297-byte record carrying serial, mode and thresholds. The
list ends with a bare 11-byte ack — nine captured frames, eight records
then the terminator.
Series III reaches the same data through a record-type discriminator on
its event walk (`0x2C` partial vs `0x46` full). Here it is a separate
cursor and the event chain does not see it at all.
"""
data = self._read(SUB_MONITOR_LOG, params=key_lo_params(key4))
return None if len(data) <= ACK_DATA_LEN else data
# ── Bulk download ─────────────────────────────────────────────────────────
def read_event_file(self, key4: bytes, size: int, *,
chunk_size: int = CHUNK_SIZE) -> bytes:
"""`0x5A` → `0xA5`. The `.IDFW`/`.IDFH` file, byte for byte.
`size` is the 4 bytes after the key in the `1E`/`1F` response. Returns
exactly that many bytes, or raises `ShortRead`.
A bounded walk — `ceil(size / chunk_size)` requests, each asking for
`min(chunk_size, remaining)` bytes:
offset = the byte count wanted (NOT an address)
params = the key on chunk 0, then a uint16 BE byte offset
response = exactly `offset + 11` bytes; file bytes are data[11:]
Verified against THOR on all six bench events (4,076 → 13,424 B):
`sum(offsets) == size` exactly, every time.
⚠ Do not port the Series III `5A` walk. Its address arithmetic caused a
5x over-read and a `>64 KB` page-boundary bug that is *still open* on
that side. Neither applies here — the cursor is a byte offset into the
file, bounded by a size the device supplied, so it cannot run past the
event.
The result feeds `micromate.idf_file.read_idf_file()` and
`/db/import/idf_file` unchanged; no new codec work is needed.
"""
if size <= 0:
raise ValueError(f"size must be positive, got {size}")
if chunk_size < 1:
raise ValueError(f"chunk_size must be positive, got {chunk_size}")
# ⚠ Driven by BYTES RECEIVED, not by chunk index.
#
# The device silently clamps an over-large request: ask for 32,768 and it
# returns exactly 16,384 — correct bytes, short length, no error. A loop
# that strides by a fixed chunk size would either fail on that or, worse,
# skip the bytes it never collected. Tracking the offset by what actually
# arrived makes the clamp a non-event: it just takes another request.
#
# That also makes this self-correcting against any short response, which
# is the failure mode this codebase has been bitten by repeatedly on the
# Series III side — there, a short read surfaced as a silently truncated
# channel.
out = bytearray()
requests = 0
while len(out) < size:
want = min(chunk_size, size - len(out))
data = self._read(
SUB_BULK_DOWNLOAD,
offset=want,
params=chunk_params(key4, len(out)),
)
requests += 1
if len(data) < _CHUNK_PREFIX:
raise ShortRead(
f"{key4.hex()} at offset {len(out)}: {len(data)} B is too "
f"short to hold a chunk header"
)
body = data[_CHUNK_PREFIX:]
if not body:
# No progress at all — continuing would spin forever.
raise ShortRead(
f"{key4.hex()} at offset {len(out)}: asked for {want} B and "
f"got none; {len(out)} of {size} B assembled"
)
if len(body) < want:
log.debug("%s: asked %d B at offset %d, served %d — clamped",
key4.hex(), want, len(out), len(body))
out += body
if len(out) != size:
raise ShortRead(
f"{key4.hex()}: assembled {len(out)} B, device promised {size}"
)
log.debug("downloaded %s: %d B in %d request(s)",
key4.hex(), len(out), requests)
return bytes(out)
# ── Plumbing ──────────────────────────────────────────────────────────────
def _read(
self,
sub: int,
*,
params: bytes = bytes(10),
offset: Optional[int] = None,
timeout: Optional[float] = None,
) -> bytes:
"""Send one read command, return the response's data section."""
return self._exchange(sub, params=params, offset=offset, timeout=timeout).data
def _exchange(
self,
sub: int,
*,
params: bytes = bytes(10),
offset: Optional[int] = None,
timeout: Optional[float] = None,
) -> MicromateFrame:
if offset is None:
offset = _OFFSETS.get(sub, READ_ALL)
# `_request` starts every exchange clean (drops any half-frame and any
# stashed frame): this is a strict request/response protocol, so anything
# already buffered when we send is stale.
return self._request(build_request(sub, offset, params), 0xFF - sub,
timeout=timeout)
def _request(self, frame: bytes, expected_sub: int, *, timeout: Optional[float] = None,
permit: frozenset = frozenset()) -> MicromateFrame:
"""Clean slate, send one frame, receive its reply. The one sequence
every exchange -- read or execute -- goes through."""
self._parser.reset()
self._pending.clear()
self._send(frame, permit=permit)
return self._recv_one(expected_sub=expected_sub, timeout=timeout,
reset_parser=False)
def execute(self, plan: "WritePlan") -> list[MicromateFrame]:
"""Transmit a `micromate.writes.WritePlan` -- the only write path.
Permission is granted for this call alone, one step at a time, and only
for SUBs under `ENABLEABLE_WRITES`. Refuses unless the last reply on
this connection carried Micromate flags (0xC5 / 0x03). Each step's ack
is awaited before the next is sent. Never retries: a timeout raises,
and what happened is the caller's to find out by reading the unit back.
"""
# Deferred: writes -> setup_block -> protocol would be circular at import.
from .writes import WritePlan
if not isinstance(plan, WritePlan):
raise TypeError(f"execute takes a WritePlan, got {type(plan).__name__}")
beyond = {st.sub for st in plan.steps} - ENABLEABLE_WRITES
if beyond:
raise OpcodeRefused(
"plan holds SUB(s) above the write ceiling: "
+ ", ".join(f"0x{s:02X}" for s in sorted(beyond)))
if self.last_flags not in (FLAGS_BLASTWARE, FLAGS_THOR):
raise OpcodeRefused(
"no Micromate-flagged reply seen on this connection -- "
"refusing to write")
acks = []
for step in plan.steps:
acks.append(self._request(step.frame, step.ack_sub,
permit=frozenset({step.sub})))
return acks
def _send(self, frame: bytes, *, permit: frozenset = frozenset()) -> None:
# The gate sees the bytes about to go out, not the caller's intent.
# `permit` is passed only via _request, from execute(), for one step.
frame = bytes(frame)
# Trust means the most recent request got a validated Micromate reply.
self.last_flags = None
# The ceiling is enforced here, where frames leave, whatever was permitted.
check_transmit(request_sub(frame), permit & ENABLEABLE_WRITES)
log.debug("TX %d bytes: %s", len(frame), frame.hex())
self._transport.write(frame)
def _recv_one(
self,
expected_sub: Optional[int] = None,
timeout: Optional[float] = None,
reset_parser: bool = True,
) -> MicromateFrame:
"""Read until one complete frame is parsed."""
deadline = time.monotonic() + (timeout or self._recv_timeout)
if reset_parser:
self._parser.reset()
self._pending.clear()
if self._pending:
return self._validate(self._pending.pop(0), expected_sub)
while time.monotonic() < deadline:
chunk = self._transport.read(4096)
if not chunk:
time.sleep(0.005)
continue
log.debug("RX %d bytes", len(chunk))
frames = self._parser.feed(chunk)
if frames:
self._pending.extend(frames[1:])
return self._validate(frames[0], expected_sub)
raise TimeoutError(
f"no frame in {timeout or self._recv_timeout:.1f}s"
+ (f" (expected SUB 0x{expected_sub:02X})" if expected_sub is not None else "")
+ f"; {self._parser.bytes_fed} bytes were received"
# That byte count is the whole point: it separates "nothing came
# back at all" from "bytes arrived but never framed", and those have
# completely different causes. It earned its keep on Series III.
)
def _validate(
self, frame: MicromateFrame, expected_sub: Optional[int]
) -> MicromateFrame:
if not frame.checksum_valid:
msg = (
f"SUB 0x{frame.sub:02X}: checksum mismatch "
f"(got 0x{frame.chk_byte:02X}, {len(frame.data)} B data)"
)
if self._strict:
raise ChecksumError(msg)
log.warning("%s — continuing (strict_checksums=False)", msg)
if expected_sub is not None and frame.sub != expected_sub:
raise UnexpectedResponse(
f"expected SUB 0x{expected_sub:02X}, got 0x{frame.sub:02X}"
)
self.last_flags = frame.flags
return frame
+89
View File
@@ -0,0 +1,89 @@
r"""Decode the Thor / Micromate (series-4) sensor self-check waveforms from an
IDFW event binary.
Reverse-engineered 2026-09-15 against 4 UM (Thor) oracle events. The IDFW
binary carries the sensor self-check in its fixed-header region (before the
waveform body), as up to four records tagged ``01 0e 3c/3d/3e/3f`` — the SAME
channel ids as the series-3 MiniMate Plus (Tran / Vert / Long / MicL), which is
the physical self-test:
* 3c / 3d / 3e = Tran / Vert / Long geophone ring-downs (a damped impulse
response — resonant frequency + damping).
* 3f = MicL pulse train (the mic's known-signal gain check). Absent
on three-channel (mic-disabled) units.
Record framing (per record)::
01 0e [id:1] [flags:3] [count:2 BE] [pad:10] [int16-BE samples × count]
\___ 18-byte header ___/
Unlike series-3's delta-coded trailing block, series-4 stores each trace as a
raw int16 big-endian array. ``count`` (the 2-byte field at header offset +8)
is the sample count; the record is padded to a fixed stride after that.
"""
from __future__ import annotations
import struct
from typing import Dict, List
# Record id → channel. Same ids/order as series-3 (minimateplus.sensor_check).
_ID_TO_CHANNEL = {0x3C: "Tran", 0x3D: "Vert", 0x3E: "Long", 0x3F: "MicL"}
_CHAIN_IDS = (0x3C, 0x3D, 0x3E, 0x3F)
_MARKER = b"\x01\x0e" # precedes the 1-byte channel id
_HEADER_LEN = 18 # bytes from the marker start to the first sample
_COUNT_OFF = 8 # 2-byte BE sample count, from the marker start
_MAX_COUNT = 4000 # sanity cap (traces are ~70-200 samples)
def _find_chain(raw: bytes):
"""Locate the sensor-check record chain. Returns a list of
``(offset, id, count)`` for the first run of markers whose ids run
3c, 3d, 3e[, 3f] in order, or ``[]``.
Records are padded to a fixed stride, so the next marker is not at
``header + count*2``; instead collect every ``01 0e [id]`` marker with a
sane count and take the first id-ordered run. Validating the id sequence
(not a lone ``01 0e 3c``) keeps a stray marker in the waveform body from
matching — the real chain sits in the fixed header, ahead of the body.
"""
n = len(raw)
markers = []
for p in range(n - _HEADER_LEN):
if raw[p:p + 2] == _MARKER and raw[p + 2] in _ID_TO_CHANNEL:
count = int.from_bytes(raw[p + _COUNT_OFF:p + _COUNT_OFF + 2], "big")
if 0 < count <= _MAX_COUNT:
markers.append((p, raw[p + 2], count))
for i, (off, rid, _c) in enumerate(markers):
if rid != 0x3C:
continue
run = [markers[i]]
for m in markers[i + 1:]:
if len(run) < len(_CHAIN_IDS) and m[1] == _CHAIN_IDS[len(run)]:
run.append(m)
else:
break
if len(run) >= 3: # 3-channel (mic-disabled) units are valid
return run
return []
def decode_idf_sensor_check(raw: bytes) -> Dict[str, List[int]]:
"""Decode the sensor self-check traces from a Thor/Micromate IDFW binary.
Returns ``{"Tran": [...], "Vert": [...], "Long": [...], "MicL": [...]}`` in
raw int16 ADC counts (MicL omitted on 3-channel units), or ``{}`` if the
binary carries no sensor-check chain (a non-IDF file, or an IDFH histogram).
"""
chain = _find_chain(raw)
if not chain:
return {}
out: Dict[str, List[int]] = {}
for off, rid, count in chain:
start = off + _HEADER_LEN
blob = raw[start:start + count * 2]
if len(blob) < count * 2:
continue
out[_ID_TO_CHANNEL[rid]] = list(struct.unpack(">%dh" % count, blob))
return out
+154
View File
@@ -0,0 +1,154 @@
"""
setup_block.py — the Micromate setup block (`SUB 0x1A`), decoded.
Pure byte interpretation: no I/O, no device. `MicromateClient.get_setup()`
does the read and hands the content here.
Every offset below is into **content** (response data minus its 11-byte prefix)
and was measured on UM20147 (`11.0BD`) by changing one setting on the unit's own
keypad and watching which bytes moved, 2026-10-17/19. Method, grades and the
fields deliberately left out are in docs/micromate_protocol_reference.md, under
*The `0x1A` field map from a keypad pass* and the 2026-10-19 section after it.
"""
from __future__ import annotations
import struct
from .models import MicromateSetup
from .protocol import ProtocolError
class SetupChecksumError(ProtocolError):
"""A config block's trailing CRC does not match its contents."""
_CRC_POLY = 0x1021
_CRC_INIT = 0x1D0F # CRC-16/AUG-CCITT
_CONTENT_SIZE = 2092 # = content[0:2] (2090) + the 2-byte CRC
# ── Head of the block ─────────────────────────────────────────────────────────
_MODE = 5 # 01 Waveform · 02 Manual · 03 Histogram · 04 Combo
_SAMPLE_RATE = slice(6, 8) # uint16 BE ⚠ 4096 puts a literal 0x10 here
_HIST_INTERVAL = slice(8, 10) # uint16 BE seconds
_PRETRIGGER = 12 # f32 BE, NEGATIVE seconds
_STOP_MODE = 17 # 00 Fixed · 01 Auto (u8 or u16 BE [16:18] — unresolved)
_RECORD_TIME = 18 # f32 BE seconds
_AUTO_STOP = 23 # seconds (u8 or u16 BE [22:24] — unresolved)
_SENSORS = 25 # bitmask: 0x07 geophones, 0x08 mic
_TRIGGERS = 29 # same bits: which sensors may trigger
_DISTANCE = 30 # f32 BE metres (keypad: ft / 3.2808)
_CHARGE = 34 # f32 BE kg (keypad: lb / 2.21)
_REPORT_FLAGS = 39 # 0x02 job number on · 0x08 scaled distance on · 0x01 ?
_JOB_NUMBER = slice(40, 42) # uint16 BE
_NAME = slice(42, 86) # setup file name, null-padded
_GEO_BITS, _MIC_BIT = 0x07, 0x08
_JOB_ON, _SCALED_ON = 0x02, 0x08
# ── Notes: four [label 22][value 42] pairs on a 64-byte stride ────────────────
_NOTE_LABEL, _NOTE_VALUE, _NOTE_STRIDE, _NOTES = 122, 144, 64, 4
# ── Channel blocks, 48 bytes each from content[1708] ──────────────────────────
# 1-3 are the geophones. Block 4 is the ACTIVE mic: a byte copy of block 5
# (stored linear settings) or block 6 (stored sound-level settings). Read the
# mic from block 4 only — 5 and 6 describe whichever mic is NOT selected.
_CHANNELS, _CHANNEL_SIZE = 1708, 48
_CH_SENSOR_CODE = slice(4, 8) # uint32 BE: 1 geophone, 2 linear mic, 9 SLM, 0 off
_CH_TRIGGER = 30 # f32 BE: geophone in/s, linear mic psi
_ACTIVE_MIC = 3 # block index (0-based)
_MIC_TYPES = {2: "linear", 9: "sound_level"}
def _crc16_aug_ccitt(data: bytes) -> int:
c = _CRC_INIT
for b in data:
c ^= b << 8
for _ in range(8):
c = ((c << 1) ^ _CRC_POLY) & 0xFFFF if c & 0x8000 else (c << 1) & 0xFFFF
return c
def crc_ok(content: bytes) -> bool:
"""True if a config block's trailing checksum matches its contents.
One rule covers the setup (`0x1A`), preferences (`0x08`) and `0x2E` blocks:
``content[0:2]`` is a uint16 BE length N, and a CRC-16/AUG-CCITT over
``content[0:N-2]`` is stored big-endian at ``content[N:N+2]``. The two bytes
at ``[N-2:N]`` are zero and not covered. `0x2C` (call-home) has no checksum.
A block too short to hold its own declared length reads as bad, not as an
error: a truncated read is exactly what this exists to catch.
"""
if len(content) < 2:
return False
n = int.from_bytes(content[0:2], "big")
if n < 2 or len(content) < n + 2:
return False
return _crc16_aug_ccitt(content[: n - 2]) == int.from_bytes(content[n : n + 2], "big")
def _f32(c: bytes, offset: int) -> float:
return struct.unpack_from(">f", c, offset)[0]
def _ascii(buf: bytes) -> str:
return buf.split(b"\x00")[0].decode("ascii", "replace").strip()
def _channel(c: bytes, index: int) -> bytes:
start = _CHANNELS + index * _CHANNEL_SIZE
return c[start : start + _CHANNEL_SIZE]
def decode_setup(content: bytes, *, verify: bool = True) -> MicromateSetup:
"""Decode a setup block's content (``0x1A`` data minus its 11-byte prefix).
Raises ``SetupChecksumError`` if the trailing CRC does not match — unless
``verify=False``, which decodes anyway, for looking at what a bad read held.
A block shorter than 2,092 bytes raises ``ProtocolError`` either way: the
checksum is optional, the bounds are not.
"""
if len(content) < _CONTENT_SIZE:
raise ProtocolError(f"setup block content is {len(content)} B, need {_CONTENT_SIZE}")
if verify and not crc_ok(content):
raise SetupChecksumError(
"setup block checksum mismatch — a short or corrupt read "
"(decode_setup(..., verify=False) to inspect it anyway)"
)
c = content
mic = _channel(c, _ACTIVE_MIC)
mic_code = int.from_bytes(mic[_CH_SENSOR_CODE], "big")
mic_type = _MIC_TYPES.get(mic_code, f"unknown ({mic_code})")
flags = c[_REPORT_FLAGS]
notes = {}
for n in range(_NOTES):
label = _ascii(c[_NOTE_LABEL + n * _NOTE_STRIDE : _NOTE_VALUE + n * _NOTE_STRIDE])
value = _ascii(c[_NOTE_VALUE + n * _NOTE_STRIDE : _NOTE_LABEL + (n + 1) * _NOTE_STRIDE])
notes[label] = value
return MicromateSetup(
name=_ascii(c[_NAME]),
record_mode=c[_MODE],
sample_rate=int.from_bytes(c[_SAMPLE_RATE], "big"),
histogram_interval_s=int.from_bytes(c[_HIST_INTERVAL], "big"),
pretrigger_s=-_f32(c, _PRETRIGGER),
auto_record_stop=bool(c[_STOP_MODE]),
record_time_s=_f32(c, _RECORD_TIME),
auto_stop_after_s=c[_AUTO_STOP],
geophones_active=bool(c[_SENSORS] & _GEO_BITS),
mic_active=bool(c[_SENSORS] & _MIC_BIT),
trigger_on_geophones=bool(c[_TRIGGERS] & _GEO_BITS),
trigger_on_mic=bool(c[_TRIGGERS] & _MIC_BIT),
geo_trigger_ips=tuple(_f32(_channel(c, i), _CH_TRIGGER) for i in range(3)),
mic_type=mic_type,
mic_trigger_psi=_f32(mic, _CH_TRIGGER) if mic_type == "linear" else None,
job_number_enabled=bool(flags & _JOB_ON),
job_number=int.from_bytes(c[_JOB_NUMBER], "big"),
scaled_distance_enabled=bool(flags & _SCALED_ON),
distance_m=_f32(c, _DISTANCE),
charge_weight_kg=_f32(c, _CHARGE),
notes=notes,
raw=c,
)
+181
View File
@@ -0,0 +1,181 @@
"""Write plans for a Micromate: the exact frames a write would send, in order.
A plan is what a dry run returns. Building one sends nothing; transmitting it
is `MicromateProtocol.execute(plan)` and nothing else: the connection holds no
write permission of its own (see `micromate.opcodes`).
Every input is the unit's OWN read of the block being written (content, i.e.
response data[11:]), and every plan sends back exactly what was read except
the one thing the operation changes. THOR works the same way, and the
reproduction tests hold the plans to THOR's frames byte for byte.
Offsets are THOR's observed constants. 🔶 Each was seen at one block size
only, so a plan refuses a block of any other size rather than guess.
"""
from __future__ import annotations
from dataclasses import dataclass, field
from typing import FrozenSet, List, Tuple
from .framing import build_request
from .opcodes import CROSS_SERIES_COLLISIONS, WRITE_SUBS, OpcodeRefused
from .setup_block import crc_ok
_CONFIRM = 0xFFFF
# block content sizes THOR's offsets were observed at (all on UM12947 / 11.0CB)
_PREFS_LEN, _TRIGGER_LEN, _SETUP_LEN, _CALL_HOME_LEN = 90, 28, 2092, 126
_NAME_FIELD = 256
@dataclass(frozen=True)
class WriteStep:
sub: int
offset: int
data: bytes = b""
params: bytes = field(default=bytes(10))
what: str = ""
def __post_init__(self) -> None:
# Freeze the bytes: a caller's bytearray must not change a validated step.
object.__setattr__(self, "data", bytes(self.data))
object.__setattr__(self, "params", bytes(self.params))
if len(self.params) != 10:
raise ValueError(f"params must be 10 bytes, got {len(self.params)}")
if not 0 <= self.offset <= 0xFFFF:
raise ValueError(f"offset 0x{self.offset:X} does not fit a uint16")
if not 0 <= self.sub <= 0xFF:
raise ValueError(f"SUB {self.sub!r} does not fit a byte")
@property
def ack_sub(self) -> int:
return 0xFF - self.sub
@property
def frame(self) -> bytes:
return build_request(self.sub, self.offset, self.params, self.data)
def describe(self) -> dict:
return {"sub": f"0x{self.sub:02X}", "what": self.what,
"offset": f"0x{self.offset:04X}", "data_len": len(self.data),
"expect_ack": f"0x{self.ack_sub:02X}", "frame": self.frame.hex()}
@dataclass(frozen=True)
class WritePlan:
action: str
steps: Tuple[WriteStep, ...]
warnings: Tuple[str, ...] = ()
def __post_init__(self) -> None:
# Copy: a caller's list must not be able to add a step after validation.
object.__setattr__(self, "steps", tuple(self.steps))
object.__setattr__(self, "warnings", tuple(self.warnings))
for s in self.steps:
if not isinstance(s, WriteStep):
raise TypeError(f"a plan holds WriteStep objects, got {type(s).__name__}")
if s.sub in CROSS_SERIES_COLLISIONS:
raise OpcodeRefused(
f"a plan cannot hold SUB 0x{s.sub:02X}: {CROSS_SERIES_COLLISIONS[s.sub]}")
if s.sub not in WRITE_SUBS:
raise ValueError(f"SUB 0x{s.sub:02X} is not a write opcode")
@property
def subs(self) -> FrozenSet[int]:
return frozenset(s.sub for s in self.steps)
def frames(self) -> List[bytes]:
return [s.frame for s in self.steps]
def describe(self) -> dict:
return {"action": self.action, "sends_nothing": True,
"warnings": list(self.warnings),
"steps": [s.describe() for s in self.steps]}
def plan_start_monitoring() -> WritePlan:
return WritePlan("start monitoring", (WriteStep(0x96, _CONFIRM, what="start monitoring"),))
def plan_stop_monitoring() -> WritePlan:
return WritePlan("stop monitoring", (WriteStep(0x97, _CONFIRM, what="stop monitoring"),))
def plan_call_home_enabled(call_home: bytes, enabled: bool) -> WritePlan:
"""Read `0x2C`, flip bit 0 of content[5], send the rest back byte for byte.
Bit 0 of `[5]` is the enable. 🔶 UM12947 (THOR's unit) read 0x05 enabled /
0x04 disabled, bit 2 set in both; UM20147 reads 0x01 (measured, phase-2 dry
run). So on UM20147 "off" writes 0x00, a value no capture shows being
written: the target value there is unobserved, and the plan's `warnings`
say so. `[118:120]` is unit-maintained and THOR echoes it.
"""
if len(call_home) != _CALL_HOME_LEN:
raise ValueError(f"call-home content must be {_CALL_HOME_LEN} B "
f"(the size THOR's offset was seen at), got {len(call_home)}")
b5 = (call_home[5] | 0x01) if enabled else (call_home[5] & 0xFE)
data = call_home[:5] + bytes([b5]) + call_home[6:]
what = "call-home " + ("enable" if enabled else "disable")
start = call_home[5]
warnings = []
if start not in (0x04, 0x05) or b5 not in (0x04, 0x05):
warnings.append(f"content[5] 0x{start:02X} -> 0x{b5:02X}: THOR was only ever "
"seen writing 0x04/0x05 (UM12947); this value is unobserved")
if b5 == start:
warnings.append(f"the unit is already call-home {'enabled' if enabled else 'disabled'}"
" -- this write changes nothing")
return WritePlan(what, (
WriteStep(0x7E, 0x007E, data, what="call-home config write"),
WriteStep(0x7F, _CONFIRM, what="call-home config confirm"),
), tuple(warnings))
def _checked(block: bytes, size: int, label: str) -> bytes:
if len(block) != size:
raise ValueError(f"{label} block size {len(block)} B is not the {size} B "
"THOR's offset was observed at -- refusing to guess")
if int.from_bytes(block[0:2], "big") != size - 2:
raise ValueError(f"{label} block's own header says "
f"{int.from_bytes(block[0:2], 'big')}, expected {size - 2} -- "
"not the block it claims to be")
if not crc_ok(block):
raise ValueError(f"{label} block failed its checksum -- refusing to write a "
"corrupt read back to the unit")
return block
def plan_setup_push(prefs: bytes, trigger: bytes, setup: bytes, name: str) -> WritePlan:
"""Rewrite a setup as THOR does: read 0x08, 0x2E, 0x1A, send each back.
No field editing here (phase 5). Each block goes back with its length echo
[0:3] zeroed; the unit recomputes the CRCs, so 0x68 and 0x71 drop the CRC
slot and 0x82 sends it zeroed -- exactly THOR's frames.
⚠ `0x1A` reads the keypad's edit buffer live. A setup read taken while
someone is in the unit's menu includes their unsaved edits, and pushing
this plan would commit them.
The name goes out exactly as given. `MicromateClient.get_active_setup()`
strips whitespace, so a setup name with leading or trailing spaces would
not round-trip through it; phase 5 decides whether to take the unstripped
name from the 0x41 read.
"""
_checked(prefs, _PREFS_LEN, "preferences (0x08)")
_checked(trigger, _TRIGGER_LEN, "trigger (0x2E)")
_checked(setup, _SETUP_LEN, "setup (0x1A)")
try:
raw = name.encode("ascii")
except UnicodeEncodeError:
raise ValueError(f"setup name must be ASCII: {name!r}") from None
if not raw or b"\x00" in raw or len(raw) >= _NAME_FIELD:
raise ValueError(f"setup name must be 1-{_NAME_FIELD - 1} ASCII bytes "
f"with no NUL: {name!r}")
return WritePlan(f"setup push: {name}", (
WriteStep(0xDA, 0x0100, raw.ljust(_NAME_FIELD, b"\x00"), what="setup file name"),
WriteStep(0x68, 0x005A, bytes(3) + prefs[3:88], what="preferences block"),
WriteStep(0x73, _CONFIRM, what="preferences confirm"),
WriteStep(0x82, 0x001C, bytes(3) + trigger[3:26] + bytes(2), what="trigger block"),
WriteStep(0x83, _CONFIRM, what="trigger confirm"),
WriteStep(0x71, 0x082C, bytes(3) + setup[3:2090], what="setup block"),
WriteStep(0x72, _CONFIRM, what="setup confirm"),
))
+75
View File
@@ -0,0 +1,75 @@
"""Structural annotation of a Series-3 Blastware waveform binary.
Pure, no I/O: takes the raw file bytes and returns a flat, gap-free tiling of
labelled :class:`Span` regions for a hex viewer to paint. Every byte is
covered — anything the decoder can't account for becomes an ``unknown`` span,
so undecoded regions (e.g. a stored spectral/FFT block, if one exists) stand
out instead of hiding.
File layout (see ``blastware_file.py``): ``[header][21B STRT][body][26B footer]``.
The body is the record chain walked by :func:`waveform_codec.walk_records`.
"""
from __future__ import annotations
from dataclasses import dataclass
from typing import List
from .waveform_codec import walk_records
_STRT_LEN = 21
_FOOTER_LEN = 26
@dataclass
class Span:
start: int # inclusive byte offset
end: int # exclusive byte offset
label: str # human-readable description
kind: str # 'header' | 'strt' | 'sample' | 'footer' | 'unknown'
def _tile(known: List[Span], total: int) -> List[Span]:
"""Sort *known* spans and fill every gap with an ``unknown`` span, so the
result is a contiguous, non-overlapping tiling of ``[0, total)``. Overlaps
are resolved by clamping to the running position (first writer wins)."""
out: List[Span] = []
pos = 0
for s in sorted(known, key=lambda x: (x.start, x.end)):
if s.end <= pos:
continue # fully behind — dropped overlap
start = max(s.start, pos)
if start > pos:
out.append(Span(pos, start, "unknown", "unknown"))
out.append(s if start == s.start else Span(start, s.end, s.label, s.kind))
pos = s.end
if pos < total:
out.append(Span(pos, total, "unknown", "unknown"))
return out
def annotate_blastware_binary(raw: bytes) -> List[Span]:
"""Annotate a Series-3 waveform binary into a gap-free list of spans."""
total = len(raw)
strt_pos = raw.find(b"STRT")
if strt_pos < 0:
return [Span(0, total, "unrecognized — no STRT record", "unknown")]
known: List[Span] = []
if strt_pos > 0:
known.append(Span(0, strt_pos, "File header", "header"))
known.append(Span(strt_pos, strt_pos + _STRT_LEN, "STRT record", "strt"))
body_start = strt_pos + _STRT_LEN
footer_start = total - _FOOTER_LEN
if footer_start >= body_start:
known.append(Span(footer_start, total, "File footer", "footer"))
else:
footer_start = total # file too short for a footer
body = raw[body_start:footer_start]
for rec in walk_records(body):
hi, lo = rec["mode"]
label = f"{rec['channel']} record (seg {rec['segment_index']}, mode {hi:02x} {lo:02x})"
known.append(Span(body_start + rec["offset"], body_start + rec["end"], label, "sample"))
return _tile(known, total)
+37 -21
View File
@@ -552,6 +552,31 @@ def classify_frame(frame: S3Frame) -> str:
# ── Waveform file writer ───────────────────────────────────────────────────────────
_A5_HEADER = 12 # every A5 reply's header after the probe, in stripped bytes
_A5_TERM_HEADER = 11 # the TERM reply's header
def _raw_skip(data, stripped_len: int) -> int:
"""Raw bytes of `data` covering its first `stripped_len` bytes, an inner DLE
pair (10 02 / 10 03 / 10 04) counting as one -- the rule `probe_skip` and
`_strip_inner_frame_dles` already use.
Every A5 header is 12 bytes in that sense (the TERM's 11), but its raw length
varies with the address it echoes: 13 for the metadata pages at 0x1002 and
0x1004, and for a sample chunk that lands there; 12 otherwise. A fixed
"frames 1 and 2 are metadata pages, skip 13" cut two bytes from every
non-first event, which has no metadata pages (BE9441, 2026-10-25).
"""
raw_i = stripped = 0
while stripped < stripped_len and raw_i < len(data):
if data[raw_i] == 0x10 and raw_i + 1 < len(data) and data[raw_i + 1] in (0x02, 0x03, 0x04):
raw_i += 2
else:
raw_i += 1
stripped += 1
return raw_i
def extract_body_bytes(a5_frames):
"""Reconstruct the Blastware-file body bytes from a list of A5 frames.
@@ -614,16 +639,11 @@ def extract_body_bytes(a5_frames):
all_bytes = bytearray()
for fi, frame in enumerate(body_frames):
if fi == 0:
skip = probe_skip
elif fi in (1, 2):
skip = 13 # metadata pages
else:
skip = 12 # sample chunks
skip = probe_skip if fi == 0 else _raw_skip(frame.data, _A5_HEADER)
all_bytes.extend(_frame_body_bytes(frame, skip))
if term_frame is not None:
all_bytes.extend(_frame_body_bytes(term_frame, 11))
all_bytes.extend(_frame_body_bytes(term_frame, _raw_skip(term_frame.data, _A5_TERM_HEADER)))
# Find the first valid `0e 08` footer marker.
footer_pos = -1
@@ -786,9 +806,9 @@ def write_blastware_file(
# Frame contribution loop (v0.14.0 BW-exact walk).
# Skip values:
# probe (fi=0): probe_skip
# meta@0x1002 (fi=1): 13 (6-byte inner header)
# meta@0x1004 (fi=2): 13 (6-byte inner header)
# sample chunks (fi=3+): 12 (5-byte inner header)
# every later frame: 12 stripped bytes (_raw_skip): 13 raw for an
# address with an inner DLE pair (the metadata
# pages 0x1002 / 0x1004, or a chunk there), else 12
last_fi = len(body_frames) - 1
log.debug(
@@ -799,12 +819,7 @@ def write_blastware_file(
all_bytes = bytearray()
for fi, frame in enumerate(body_frames):
if fi == 0:
skip = probe_skip
elif fi in (1, 2):
skip = 13 # metadata pages
else:
skip = 12 # sample chunks
skip = probe_skip if fi == 0 else _raw_skip(frame.data, _A5_HEADER)
contribution = _frame_body_bytes(frame, skip)
log.debug("write_blastware_file: fi=%d skip=%d raw_data=%d contribution=%d",
@@ -812,14 +827,15 @@ def write_blastware_file(
all_bytes.extend(contribution)
# Terminator contributes its content, which ends with the 26-byte footer.
# skip=11 (not 12) because the terminator's inner frame header is 4 bytes,
# one shorter than chunk frames' 5-byte inner header. Confirmed 2026-04-21.
# 11 stripped bytes (not 12): the terminator's inner frame header is one
# shorter than a chunk's. Confirmed 2026-04-21.
if term_frame is not None:
term_contribution = _frame_body_bytes(term_frame, 11)
term_skip = _raw_skip(term_frame.data, _A5_TERM_HEADER)
term_contribution = _frame_body_bytes(term_frame, term_skip)
log.debug(
"write_blastware_file: term_frame data_len=%d skip=11 "
"write_blastware_file: term_frame data_len=%d skip=%d "
"contribution_len=%d first8=%s",
len(term_frame.data),
len(term_frame.data), term_skip,
len(term_contribution),
term_contribution[:8].hex() if len(term_contribution) >= 8 else term_contribution.hex(),
)
+135 -17
View File
@@ -34,7 +34,7 @@ import re
import struct
from typing import Optional
from .framing import S3Frame
from .framing import S3Frame, unescape_reply
from .models import (
CallHomeConfig,
ComplianceConfig,
@@ -60,16 +60,18 @@ from .transport import SerialTransport, BaseTransport
log = logging.getLogger(__name__)
# SUB 0x1C state-flag values measured while a unit was monitoring: 0x10 (BE11529,
# 2026-04-08, 98 frames) and 0x0B (BE9441 recording a histogram, 2026-10-26).
# Idle is 0x00 on both.
S3_MONITORING_FLAGS = frozenset({0x10, 0x0B})
# ── Module-level constants ────────────────────────────────────────────────────
# Trigger config payload hardcoded from 3-11-26 BW TX capture (BW frame 108).
# No SUB 0x22 read exists in the capture — Blastware writes this fixed blob.
# 29 bytes: [00][1A][D5][00][00][10][03][08][0A] + 18×FF + [00][00]
_TRIGGER_DATA_HARDCODED: bytes = bytes.fromhex(
"001ad500001003080a"
"ffffffffffffffffffffffffffffffffffffff"
"0000"
)
# ⚠ RETRACTED 2026-10-27 (#46): a trigger block "hardcoded from 3-11-26 -- no
# read exists, Blastware writes this fixed blob". Blastware reads it first (SUB
# 0x2E), and its byte 5 differs by unit and session (01 / 03 / 04 on record), so
# the copy changed that setting on any unit that differed. apply_config reads
# the unit's own block (MiniMateProtocol.read_trigger_config).
# Compliance ASCII slot format (confirmed from 3-11-26 capture + label search):
# Each label occupies a 64-byte slot.
@@ -450,7 +452,7 @@ class MiniMateClient:
proto.confirm_erase_all()
log.info("delete_all_events: erase confirmed — device memory cleared")
def get_events(self, full_waveform: bool = False, debug: bool = False, stop_after_index: Optional[int] = None, skip_waveform_for_keys: Optional[set] = None, skip_waveform_for_events: Optional[dict] = None, extra_chunks_after_metadata: int = 1) -> list[Event]:
def get_events(self, full_waveform: bool = False, debug: bool = False, stop_after_index: Optional[int] = None, skip_waveform_for_keys: Optional[set] = None, skip_waveform_for_events: Optional[dict] = None, extra_chunks_after_metadata: int = 1, headers_only: bool = False, only_key: Optional[bytes] = None, only_key_timestamp: Optional[str] = None) -> list[Event]:
"""
Download all stored events from the device using the confirmed
1E → 0A → 0C → 5A → 1F event-iterator protocol.
@@ -479,8 +481,26 @@ class MiniMateClient:
Raises:
ProtocolError: on unrecoverable communication failure.
headers_only: never start a 5A -- every event takes the bypass below.
only_key: download only the event with this key (in full, per
full_waveform); walk the others without their 5A, and stop once
that event is read.
only_key_timestamp: with only_key, the ISO timestamp (as
`_event_timestamp_iso` formats it, e.g. "2026-10-01T08:00:00") the
event was listed with. If the 0C at only_key says another time, or
gave none, that event is returned without its 5A -- 1F(arm), POLL
and 5A are not sent -- and the caller reports which.
Strict mode (headers_only, or only_key): a list or a one-event download
must be all or nothing, so a lost 0A or 1F reply re-raises its
ProtocolError instead of skipping an event or ending the walk early,
and a 1F that returns a key already walked raises ProtocolError.
Without those options (legacy) the walk is exactly as it was.
"""
proto = self._require_proto()
strict = headers_only or only_key is not None
# Passed only when on, so the legacy walk's 5A call is unchanged.
strict_5a = {"strict": True} if strict else {}
log.info("get_events: requesting first event (SUB 1E)")
try:
@@ -497,6 +517,7 @@ class MiniMateClient:
events: list[Event] = []
idx = 0
seen: set = set() # strict mode: keys walked, to catch a chain that does not advance
# Legacy bare-key skip set is deprecated: the device's key counter
# resets to 0x01110000 after every memory erase, so a key in this set
@@ -514,6 +535,10 @@ class MiniMateClient:
while data8[4:8] != b"\x00\x00\x00\x00":
cur_key = key4 # key for this event's 0A/1E-arm/0C/5A calls
if strict and cur_key in seen:
raise ProtocolError(
f"event chain did not advance: key {cur_key.hex()} came back twice")
seen.add(cur_key)
log.info("get_events: record %d key=%s", idx, cur_key.hex())
ev = Event(index=idx)
@@ -531,6 +556,8 @@ class MiniMateClient:
)
proceed = False
except ProtocolError as exc:
if strict:
raise
log.warning(
"get_events: 0A failed for key=%s: %s — skipping",
cur_key.hex(), exc,
@@ -577,6 +604,19 @@ class MiniMateClient:
"get_events: key=%s (key, ts=%s) match — skipping 5A bulk download",
cur_key.hex(), actual_ts,
)
elif headers_only or (only_key is not None and cur_key != only_key):
# The same bypass as a (key, ts) match: 0A + 1E(arm) + 0C were
# read; 1F(arm) + POLL + 5A are not sent, and 1F(browse) below is
# safe because no 5A was ever started.
skip_5a = True
elif (only_key is not None and only_key_timestamp is not None
and actual_ts != only_key_timestamp):
# The event at this key is not the one asked for -- erased or
# wrapped since it was listed, or its 0C reply was lost. Do
# not download it; the caller reports which.
log.info("get_events: key=%s is from %r, not %r -- no 5A",
cur_key.hex(), actual_ts, only_key_timestamp)
skip_5a = True
arm_key4: Optional[bytes] = None
a5_ok = False
@@ -617,7 +657,7 @@ class MiniMateClient:
)
a5_frames = proto.read_bulk_waveform_stream(
cur_key, stop_after_metadata=False, max_chunks=128,
include_terminator=True,
include_terminator=True, **strict_5a,
)
if a5_frames:
a5_ok = True
@@ -636,7 +676,7 @@ class MiniMateClient:
cur_key, stop_after_metadata=True,
include_terminator=True,
extra_chunks_after_metadata=extra_chunks_after_metadata,
max_chunks=128,
max_chunks=128, **strict_5a,
)
if a5_frames:
a5_ok = True
@@ -648,6 +688,8 @@ class MiniMateClient:
ev.project_info.operator if ev.project_info else None,
)
except ProtocolError as exc:
if strict:
raise # a one-event download is whole or it is an error
log.warning(
"get_events: 5A failed for key=%s: %s — metadata unavailable",
cur_key.hex(), exc,
@@ -680,6 +722,8 @@ class MiniMateClient:
key4.hex(), data8[4:8].hex(),
)
except ProtocolError as exc:
if strict:
raise
log.warning("get_events: 1F(browse) failed: %s — stopping", exc)
key4 = b"\x00\x00\x00\x00"
data8 = b"\x00\x00\x00\x00\x00\x00\x00\x00"
@@ -713,6 +757,10 @@ class MiniMateClient:
events.append(ev)
idx += 1
if only_key is not None and cur_key == only_key:
log.info("get_events: read key=%s -- stopping", cur_key.hex())
break
# Early exit: if the caller only wants events up to a specific
# index, stop iterating once we've collected it.
if stop_after_index is not None and idx > stop_after_index:
@@ -735,12 +783,44 @@ class MiniMateClient:
key4.hex(), data8[4:8].hex(),
)
except ProtocolError as exc:
if strict:
raise
log.warning("get_events: 1F failed: %s — stopping iteration", exc)
break
log.info("get_events: downloaded %d event(s)", len(events))
return events
def list_event_headers(self) -> list[Event]:
"""Every stored event's 0C record -- timestamp, type, peaks -- without its 5A.
`get_events()` downloads every event in full even for metadata
(`stop_after_metadata` is a no-op), so listing that way costs one
complete download per event. This walks 0A + 1E(arm) + 0C + 1F(browse)
per event -- the bypass `skip_waveform_for_events` already takes -- and
never starts a 5A. The events carry no `_a5_frames`.
"""
return self.get_events(headers_only=True)
def download_event_by_key(self, key4: bytes, *, expected_timestamp: Optional[str] = None) -> Optional[Event]:
"""Download ONE event in full; walk past the events before it without
their 5A. None if no full record has that key.
`get_events(stop_after_index=N)` downloads events 0..N in full and keeps
one; this downloads only the one asked for.
`expected_timestamp` (ISO, as `_event_timestamp_iso` writes it): the
time the event was listed with. If the 0C read at that key says
otherwise -- or could not be read -- the event comes back without its
5A (`_a5_frames` None) and nothing is downloaded; the caller compares
the timestamp and says which.
"""
for ev in self.get_events(full_waveform=True, only_key=key4,
only_key_timestamp=expected_timestamp):
if ev._waveform_key == key4:
return ev
return None
def download_waveform(self, event: Event) -> None:
"""
Download the full raw ADC waveform for a previously-retrieved event
@@ -876,6 +956,17 @@ class MiniMateClient:
"""
proto = self._require_proto()
# Every block is checked before the first frame goes out (review of #46,
# 2026-10-27): a block refused after 68 + 73 had been sent left a partial
# write behind. write_image is the same check each write makes.
from .protocol import (SUB_COMPLIANCE_WRITE, SUB_EVENT_INDEX_WRITE,
SUB_TRIGGER_CONFIG_WRITE, SUB_WAVEFORM_DATA_WRITE, write_image)
for sub, data in ((SUB_EVENT_INDEX_WRITE, event_index_data),
(SUB_COMPLIANCE_WRITE, compliance_data),
(SUB_TRIGGER_CONFIG_WRITE, trigger_data),
(SUB_WAVEFORM_DATA_WRITE, waveform_data)):
write_image(sub, data)
# 68 → 73
log.info("push_config_raw: write event index (SUB 68)")
proto.write_event_index(event_index_data)
@@ -954,7 +1045,7 @@ class MiniMateClient:
Write payloads:
event_index_data : 88 bytes — read live via SUB 08
compliance_data : ~2128 bytes — read live via SUB 1A (~2126 bytes, varies ±1-2) + \\x00\\x00 footer
trigger_data : 29 bytes — hardcoded from 3-11-26 capture
trigger_data : 26 bytes — read live via SUB 2E (was hard-coded; #46)
waveform_data : 204 bytes — read live via SUB 09
Raises:
@@ -974,7 +1065,8 @@ class MiniMateClient:
log.info("apply_config: reading waveform data (SUB 09)")
waveform_data = proto.read_waveform_data_raw() # 204 bytes
trigger_data = _TRIGGER_DATA_HARDCODED # 29 bytes
log.info("apply_config: reading trigger config (SUB 2E)")
trigger_data = proto.read_trigger_config() # 26 bytes, this unit's own
# 2. Patch the compliance buffer and build the 2128-byte write payload
compliance_data = _encode_compliance_config(
@@ -1120,6 +1212,17 @@ class MiniMateClient:
log.debug("poll: startup handshake")
proto.startup()
def read_serial(self) -> str:
"""The unit's own serial (SUB 0x15), on an open, polled session. The
cheap identity read the legacy write routes check before writing."""
return _decode_serial_number(self._require_proto().read(SUB_SERIAL_NUMBER)).serial
def wake(self, attempt_s: float = 5.0, deadline_s: float = 60.0) -> None:
"""SESSION_RESET + POLL, re-sent until the unit answers (see
MiniMateProtocol.wake) -- for a unit that may be busy, e.g. sensor-checking
right after a start."""
self._require_proto().wake(attempt_s=attempt_s, deadline_s=deadline_s)
# ── Monitoring ────────────────────────────────────────────────────────────
def get_monitor_status(self) -> MonitorStatus:
@@ -1231,12 +1334,15 @@ def _decode_serial_number(data: bytes) -> DeviceInfo:
# Actual serial payload starts at data[11].
actual = data[11:] if len(data) > 11 else data
# The serial is a C string: cut at the first NUL. A short serial leaves a
# stray byte after its terminator (BE9441 sends b"BE9441\x00?"), so
# stripping trailing NULs alone is not enough.
if len(actual) < 9:
# Short payload — gracefully degrade
serial = actual.rstrip(b"\x00").decode("ascii", errors="replace")
serial = actual.split(b"\x00", 1)[0].decode("ascii", errors="replace")
return DeviceInfo(serial=serial, firmware_minor=0)
serial = actual[:8].rstrip(b"\x00").decode("ascii", errors="replace")
serial = actual[:8].split(b"\x00", 1)[0].decode("ascii", errors="replace")
trail_0 = actual[8] if len(actual) > 8 else None
fw_minor = actual[9] if len(actual) > 9 else 0
@@ -2601,6 +2707,10 @@ def _decode_monitor_status(data: bytes) -> MonitorStatus:
mem_total 0x000EFFF2 = 983026 bytes ≈ 960 KB
mem_free 0x000E9E52 = 958034 bytes ≈ 935 KB
"""
# Unescape first (2026-10-26): BE9441's free memory 0x000D0E04 arrived as
# `0d 0e 10 04`, and with the parser's kept 10 every field counted from the
# end read one byte off -- 419.84 V and 251,655,168 bytes for 6.76 V and 983,028.
data = unescape_reply(data)
# The data section starts at offset 11 (after the S3 section header).
section = data[11:] if len(data) > 11 else data
@@ -2613,7 +2723,14 @@ def _decode_monitor_status(data: bytes) -> MonitorStatus:
# Confirmed from byte diff of all 144 0xE3 data frames in 4-8-26/2ndtry capture:
# section[1] = 0x00 in all IDLE frames, 0x10 in all MONITORING frames.
# (section[6] also changes but has non-binary values 0xea/0x07 — device-specific.)
is_monitoring = len(section) > 1 and section[1] == 0x10
#
# 2026-10-26: 0x0B on BE9441 recording a HISTOGRAM (confirmed at the unit);
# 0x00 on the same unit idle. Only measured values count as monitoring --
# sfm.device_access.s3.S3_RUN_STATES refuses any other for a change.
is_monitoring = len(section) > 1 and section[1] in S3_MONITORING_FLAGS
# The same byte, raw -- but only from a real section: for data of 11 bytes
# or fewer, `section` above falls back to the header itself.
state_flag = data[12] if len(data) > 12 else None
battery_v = None
memory_total = None
@@ -2639,6 +2756,7 @@ def _decode_monitor_status(data: bytes) -> MonitorStatus:
battery_v=battery_v,
memory_total=memory_total,
memory_free=memory_free,
state_flag=state_flag,
)
+69 -2
View File
@@ -50,7 +50,7 @@ SIDECAR_KIND = "sfm.event"
# bumped without a `pip install` re-run — leading to confusing stale
# version stamps in sidecars. Bump this constant and CHANGELOG.md
# together at release time.
TOOL_VERSION = "0.29.0"
TOOL_VERSION = "0.31.0" # +/sensor_check group (schema v2); gates the backfill regen
try:
# Best-effort: prefer the installed metadata when it's NEWER than the
@@ -296,6 +296,16 @@ def apply_report_to_event(event: Event, report: BwAsciiReport) -> None:
event.sample_rate = report.sample_rate_sps
if report.record_time_s is not None:
event.rectime_seconds = report.record_time_s
# The report's event_datetime is Blastware's exact trigger time (parsed
# from Event Time + Event Date). Prefer it over the binary footer's stop
# time so a report-paired import matches BW to the second.
edt = report.event_datetime
if edt is not None:
event.timestamp = Timestamp(
raw=b"", flag=0x10,
year=edt.year, unknown_byte=0, month=edt.month, day=edt.day,
hour=edt.hour, minute=edt.minute, second=edt.second,
)
def apply_bw_report_dict_to_event(event: Event, bw_report: dict) -> None:
@@ -808,6 +818,30 @@ def derive_record_type_from_filename(filename, default: str = "Waveform") -> str
return _RECORD_TYPE_BY_EXT_SUFFIX.get(ext[-1].upper(), default)
# Marker for the recording-setup config block, and the offset of the record-time
# float32 within it. The configured post-trigger record time (seconds) is a
# big-endian float32 exactly 30 bytes before the "Standard Recording Setup"
# label. Verified across the corpus reading 1.0 / 2.0 / 3.0 s on different
# setups — and ts2 - record_time reproduces Blastware's trigger to the second
# (N844LQHB: stop 10:33:32 - 3.0 = 10:33:29).
_RECSETUP_MARKER = b"Standard Recording Setup"
_RECTIME_OFFSET_BEFORE_MARKER = 30
def _parse_record_time_seconds(raw: bytes) -> Optional[float]:
"""The configured post-trigger record time in seconds, from the recording-
setup config block, or None when absent / implausible."""
a = raw.find(_RECSETUP_MARKER)
if a < _RECTIME_OFFSET_BEFORE_MARKER:
return None
off = a - _RECTIME_OFFSET_BEFORE_MARKER
try:
rt = struct.unpack(">f", raw[off:off + 4])[0]
except struct.error:
return None
return rt if 0.05 <= rt <= 600.0 else None
def read_blastware_file(path: Union[str, Path]) -> Event:
"""
Parse a Blastware waveform file into an Event.
@@ -917,6 +951,10 @@ def read_blastware_file(path: Union[str, Path]) -> Event:
# rest of the event (timestamp, waveform_key, project strings) is
# still recoverable and useful.
decoded = decode_waveform_v2(body)
# Discriminator for the timestamp logic below: a waveform (trigger) event
# vs a histogram window. Keyed on the codec, not the filename — the
# save_imported_bw path passes a tmp ".bw" name whose extension lies.
is_waveform_body = decoded is not None
if decoded is None:
decoded = decode_histogram_body(body)
if decoded is None:
@@ -948,7 +986,31 @@ def read_blastware_file(path: Union[str, Path]) -> Event:
ev.total_samples = strt_fields.get("total_samples")
ev.pretrig_samples = strt_fields.get("pretrig_samples")
if ts1 is not None:
# Event timestamp. The footer's two timestamps mean different things by
# record type:
# * Waveform: ts1 = the monitoring-SESSION start (shared across every
# event that day — a unit arming at 06:00 stamps 06:00 on all of them),
# ts2 = THIS event's recording STOP. Blastware's Date/Time is the
# TRIGGER = ts2 - record time, and the record time is a float32 in the
# recording-setup config block (see _parse_record_time_seconds), so the
# exact trigger is recoverable from the binary alone. Falls back to ts2
# (the stop, within the record duration) if the config block is absent.
# (Stamping ts1 showed the session start, hours off.)
# * Histogram / undecodable: ts1 = the window start, which IS the event
# time — keep it.
# Discriminate by ``is_waveform_body`` (the codec), not the filename.
if is_waveform_body and ts2 is not None:
_stop = datetime.datetime(ts2.year, ts2.month, ts2.day,
ts2.hour, ts2.minute, ts2.second)
_rt = _parse_record_time_seconds(raw)
_trig = _stop - datetime.timedelta(seconds=_rt) if _rt is not None else _stop
ev.timestamp = Timestamp(
raw=footer[10:18],
flag=0x10,
year=_trig.year, unknown_byte=0, month=_trig.month, day=_trig.day,
hour=_trig.hour, minute=_trig.minute, second=_trig.second,
)
elif ts1 is not None:
ev.timestamp = Timestamp(
raw=footer[2:10],
flag=0x10,
@@ -960,6 +1022,11 @@ def read_blastware_file(path: Union[str, Path]) -> Event:
project=project, client=client, operator=user, sensor_location=seisloc,
)
ev.raw_samples = samples
# Sensor self-check traces from the binary's trailing block (waveform
# events only; returns {} for histograms / when absent). Carried on the
# Event so the .h5 writer persists them device-agnostically.
from minimateplus.sensor_check import decode_sensor_check
ev.sensor_check = decode_sensor_check(raw) or None
# Only compute peaks from samples when we actually have samples.
# For events the codec couldn't decode (histogram-mode bodies, until
# the §7.6.2 histogram codec is wired in), samples is an empty dict
+118 -94
View File
@@ -28,6 +28,10 @@ De-stuffed payload layout:
DLE stuffing rule: any 0x10 byte in the payload is doubled on the wire (0x10 → 0x10 0x10).
This applies to the checksum byte too.
⚠ AMENDED 2026-10-26 (measured): a request escapes FOUR values, not one -- every 02, 03,
04 and 10 in payload and checksum gets a DLE in front. Blastware's 748 recorded requests
re-encode byte-identically under that rule (tests/test_5a_blastware_walk.py); a bare 02 or
03 left a request unanswered. See `s3_stuff()`.
Confirmed from live captures (s3_parser.py validation + raw_bw.bin / raw_s3.bin).
"""
@@ -83,6 +87,24 @@ def dle_unstuff(data: bytes) -> bytes:
# ── Checksum ─────────────────────────────────────────────────────────────────
# Every byte value a request DLE-escapes (2026-10-26, measured): Blastware's 748
# requests from a whole download session re-encode byte-identically with this set,
# payload and checksum alike. A bare 0x02 checksum or a 0x03 inside the params left
# BE9441 silent (and the 0x02 made it reset ~11 s later). It is a Micromate's set
# too (micromate.framing._ESCAPED).
_ESCAPED = frozenset({STX, ETX, 0x04, DLE})
def s3_stuff(data: bytes) -> bytes:
"""Escape every byte a request escapes: `XX` → `10 XX` for 02, 03, 04 and 10."""
out = bytearray()
for b in data:
if b in _ESCAPED:
out.append(DLE)
out.append(b)
return bytes(out)
def checksum(payload: bytes) -> int:
"""SUM8: sum of all de-stuffed payload bytes, mod 256."""
return sum(payload) & 0xFF
@@ -90,13 +112,34 @@ def checksum(payload: bytes) -> int:
# ── BW→S3 frame builder ───────────────────────────────────────────────────────
# SUB byte for 5A — used by build_5a_frame below (protocol.py has the full
# constant set; defined here to avoid a circular import).
# SUB byte for 5A (protocol.py has the full constant set; defined here to
# avoid a circular import).
SUB_5A = 0x5A
def build_5a_request(address: int, length: int) -> bytes:
"""A SUB 5A read of `length` bytes at the unit's 32-bit `address`.
Measured 2026-10-26 from Blastware downloading all 8 of BE9441's events (four
crossing a 64 KB page): a 5A request is an ORDINARY 16-byte request --
`[10 00 5A 00][length BE][address BE 4][zeros 6]`, SUM8 checksum, every
02/03/04/10 escaped -- and this rebuilds all 540 of Blastware's 5A requests
byte for byte. The older model below (`build_5a_frame`: a raw "offset_hi
0x10", an "11-byte params", "metadata pages at 0x1002 / 0x1004") was the
same bytes misread: `10 02 00` is the length 0x0200 escaped, and the
"metadata pages" are the first event's chunks at 0x0200 and 0x0400.
"""
if not 0 <= address <= 0xFFFFFFFF:
raise ValueError(f"address must fit in 32 bits, got {address:#x}")
return build_bw_frame(SUB_5A, length, address.to_bytes(4, "big") + bytes(6))
def build_5a_frame(offset_word: int, raw_params: bytes) -> bytes:
"""
⛔ SUPERSEDED 2026-10-26 by `build_5a_request` -- no production caller. Kept
because tests/test_5a_protocol.py pins its bytes against the 5-1-26 captures;
for in-page requests it emits the same bytes. Its model (below) is retracted.
Build a BW→S3 frame for SUB 5A (BULK_WAVEFORM_STREAM) that exactly
matches Blastware's wire output.
@@ -183,7 +226,14 @@ def build_5a_frame(offset_word: int, raw_params: bytes) -> bytes:
chk = (chk + s[i]) & 0xFF
i += 1
return bytes([ACK, STX]) + bytes(s) + bytes([chk, ETX])
# A checksum that is itself a framing byte is DLE-escaped. Sent bare, a
# 0x02 before ETX reads as a new STX: BE9441 never answered chunk 0x7D06
# (`... 02 03`) and rebooted ~11 s later, twice; escaped (`10 02 03`) it
# answered in 28 ms, as did checksums 0x04 and 0x10 (bench, 2026-10-26).
# The set is a Micromate's escape set (251/251 THOR requests); the MiniMate's
# de-stuffing keeps `10 02/03/04` literal and turns `10 10` into 0x10.
tail = bytes([DLE, chk]) if chk in (STX, ETX, 0x04, DLE) else bytes([chk])
return bytes([ACK, STX]) + bytes(s) + tail + bytes([ETX])
def build_bw_frame(sub: int, offset: int = 0, params: bytes = bytes(10)) -> bytes:
@@ -203,7 +253,7 @@ def build_bw_frame(sub: int, offset: int = 0, params: bytes = bytes(10)) -> byte
byte lives at params[6] (= payload[12]). Use waveform_key_params() and
token_params() helpers to build these safely.
Wire output: [ACK] [STX] dle_stuff(payload + checksum) [ETX]
Wire output: [ACK] [STX] s3_stuff(payload + checksum) [ETX]
Args:
sub: SUB command byte (e.g. 0x01 = FULL_CONFIG_READ)
@@ -226,7 +276,7 @@ def build_bw_frame(sub: int, offset: int = 0, params: bytes = bytes(10)) -> byte
offset_lo = offset & 0xFF
payload = bytes([BW_CMD, 0x00, sub, 0x00, offset_hi, offset_lo]) + params
chk = checksum(payload)
wire = bytes([ACK, STX]) + dle_stuff(payload + bytes([chk])) + bytes([ETX])
wire = bytes([ACK, STX]) + s3_stuff(payload + bytes([chk])) + bytes([ETX])
return wire
@@ -234,103 +284,34 @@ def build_bw_write_frame(
sub: int,
data: bytes,
*,
offset: int = 0,
offset: Optional[int] = None,
params: bytes = bytes(10),
) -> bytes:
"""
Build a BW→S3 write-command frame.
"""A write request: the standard 16-byte request followed by `data`, escaped
and checksummed like every other request (s3_stuff, SUM8).
Write frames extend the standard 16-byte read header with a variable-length
data payload. They use a different checksum formula from read frames.
`offset` is the payload's [4:6] field -- the data's LENGTH; it defaults to
len(data), which is what Blastware sends on every write on record.
**CRITICAL: Write frames use minimal DLE stuffing.**
Measured 2026-10-26/27 (issue #46): all of Blastware's requests from February
to October 2026 -- 3,869 frames in the uploaded captures plus BE9441's 26
write frames tonight -- rebuild byte for byte this way, the 77 write frames
that carry data included (event index 68, compliance 71, trigger 82, waveform
data 69).
Unlike read frames (build_bw_frame), write frames do NOT apply full DLE
stuffing to the payload. Only the BW_CMD byte (0x10) at position [0] is
doubled to 0x10 0x10 on the wire. All other bytes — flags, sub, offset,
params, data, and checksum — are written RAW with no stuffing, even if they
contain 0x10 bytes (e.g. offset_hi=0x10 for compliance chunks, or 0x10
bytes in the write data payload).
Confirmed from 3-11-26 BW TX capture (frames 102–112): all 11 write frames
match the rule "double BW_CMD only; everything else raw." ✅ 2026-04-07.
Wire layout:
[41] ACK
[02] STX
[10 10] BW_CMD doubled (the ONLY DLE stuffing applied)
[00] flags
[sub] write command byte (0x68–0x83)
[00] always zero
[hi][lo] offset as uint16 BE (raw; NOT stuffed even if hi=0x10)
[params] 10 bytes (raw)
[data] variable-length write payload (raw; NOT stuffed)
[chk] checksum byte (raw; NOT stuffed even if 0x10)
[03] ETX
De-stuffed payload (for checksum computation):
[0] BW_CMD 0x10
[1] flags 0x00
[2] SUB write command byte
[3] 0x00 always zero
[4] offset_hi
[5] offset_lo
[6:16] params 10 bytes
[16:] data write payload
[-1] chk
**Checksum formula (confirmed 2026-03-12 from 3-11-26 BW TX capture):**
chk = (sum(b for b in payload[2:] if b != 0x10) + 0x10) % 256
where payload = destuffed content BEFORE appending chk.
This skips all 0x10 bytes in payload[2:] (sub onwards), including any
0x10 bytes in the offset, params, data, and the checksum byte itself.
The offset field [4:6] meaning per write SUB:
- SUBs 68, 69, 82 (single-chunk writes): offset = data[1] + 2, where
data[1] is an embedded length field in the write payload.
Confirmed from capture: 68→0x5A (data[1]=0x58+2), 82→0x1C
(data[1]=0x1A+2), 69→0xCA (data[1]=0xC8+2).
- SUB 71 (multi-chunk compliance): 0x1004 for full chunks, 0x002C
for the final partial chunk.
- Confirm frames (72, 73, 74, 83): offset=0, no data.
Args:
sub: Write command SUB byte.
data: Write payload (variable length; empty for confirm frames).
offset: 16-bit value placed at [4:6]. See per-SUB notes above.
params: 10 bytes placed at [6:16]. All-zero for most writes; compliance
chunk writes use chunk-specific values.
Returns:
Complete frame bytes ready to write to the transport.
⚠ RETRACTED: "only BW_CMD is doubled, everything else raw" and the "DLE-aware
checksum" `(sum of payload[2:] skipping 0x10) + 0x10`. That model rebuilt the
March frames only because it was fitted to data that still held its escape
bytes; the "data length 91, offset 90" it explained was 90 bytes plus one
escape. It got 7 of every 13 frames in a config write wrong.
"""
if len(params) != 10:
raise ValueError(f"params must be exactly 10 bytes, got {len(params)}")
if offset > 0xFFFF:
raise ValueError(f"offset must fit in uint16, got {offset:#06x}")
offset_hi = (offset >> 8) & 0xFF
offset_lo = offset & 0xFF
# Destuffed payload (used only for checksum; not sent directly)
payload_no_chk = bytes([BW_CMD, 0x00, sub, 0x00, offset_hi, offset_lo]) + params + data
# Large-frame checksum: sum payload[2:] skipping all 0x10 bytes, add 0x10.
# Applied to the destuffed representation — confirms correctly against
# all 11 write frames in the 3-11-26/170151 BW TX capture. ✅
chk = (sum(b for b in payload_no_chk[2:] if b != 0x10) + 0x10) & 0xFF
# Wire construction: only BW_CMD is doubled; everything else is raw.
# Do NOT use dle_stuff() here — that would incorrectly double 0x10 bytes
# in the offset, params, and data sections.
wire = (
bytes([ACK, STX]) # Frame prefix (not part of payload)
+ bytes([BW_CMD, BW_CMD]) # BW_CMD doubled (only DLE stuffing applied)
+ payload_no_chk[1:] # flags, sub, offset, params, data — RAW
+ bytes([chk]) # checksum — RAW
+ bytes([ETX]) # Frame terminator
)
return wire
length = len(data) if offset is None else offset
if not 0 <= length <= 0xFFFF:
raise ValueError(f"length must fit in 16 bits, got {length:#x}")
payload = bytes([BW_CMD, 0x00, sub, 0x00, (length >> 8) & 0xFF, length & 0xFF]) + params + data
return bytes([ACK, STX]) + s3_stuff(payload + bytes([checksum(payload)])) + bytes([ETX])
def waveform_key_params(key4: bytes) -> bytes:
@@ -389,6 +370,9 @@ def token_params(token: int = 0) -> bytes:
def bulk_waveform_params(key4: bytes, counter: int, *, is_probe: bool = False) -> bytes:
"""
⛔ SUPERSEDED 2026-10-26 by `build_5a_request` / `parse_strt_end_key` -- no
production caller; kept for tests/test_5a_protocol.py. See build_5a_request.
Build the 10-byte params block for SUB 5A (BULK_WAVEFORM_STREAM) requests.
Confirmed 2026-04-02 from 1-2-26 BW TX capture analysis:
@@ -434,6 +418,9 @@ def bulk_waveform_params(key4: bytes, counter: int, *, is_probe: bool = False) -
def bulk_waveform_term_params(key4: bytes, counter: int) -> bytes:
"""
⛔ SUPERSEDED 2026-10-26 by `build_5a_request` / `parse_strt_end_key` -- no
production caller; kept for tests/test_5a_protocol.py. See build_5a_request.
⛔ DEPRECATED — DO NOT USE IN NEW CODE.
This is the v1 termination params helper, paired with the broken
@@ -470,6 +457,9 @@ def bulk_waveform_term_v2(
last_chunk_counter: int,
) -> tuple[int, bytes]:
"""
⛔ SUPERSEDED 2026-10-26 by `build_5a_request` / `parse_strt_end_key` -- no
production caller; kept for tests/test_5a_protocol.py. See build_5a_request.
Compute the SUB 5A TERM frame's offset_word and 10-byte params block.
Confirmed across 3 events (4-27-26 + 5-1-26 captures):
@@ -541,8 +531,42 @@ def bulk_waveform_term_v2(
STRT_MARKER = b"STRT"
def unescape_reply(data: bytes) -> bytes:
"""A reply's data with each kept escape removed: `10 02/03/04` → `02/03/04`.
The unit escapes 02, 03, 04 and 10 in its replies exactly as requests do
(748/748 replies, 2026-10-26). S3FrameParser collapses `10 10` but keeps the
`10` of `10 02/03/04` (inner-frame markers to it), so its `.data` carries an
extra byte before each 02/03/04 value -- harmless for fields read before the
escape, one byte off for any read after it, or counted from the end."""
out, i = bytearray(), 0
while i < len(data):
if data[i] == DLE and i + 1 < len(data) and data[i + 1] in (STX, ETX, 0x04):
i += 1
continue
out.append(data[i])
i += 1
return bytes(out)
def parse_strt_end_key(a5_data: bytes) -> Optional[int]:
"""The event's FULL 32-bit end key from the STRT record in an A5 reply's
data, or None. The page byte is part of it: an event that ends in the next
64 KB page reads e.g. 0x011216C4 here, where `parse_strt_end_offset` gave
0x16C4. Read after `unescape_reply`."""
out = unescape_reply(a5_data)
pos = out.find(STRT_MARKER)
if pos < 0 or pos + 10 > len(out):
return None
return int.from_bytes(out[pos + 6:pos + 10], "big")
def parse_strt_end_offset(a5_data: bytes) -> Optional[int]:
"""
⛔ SUPERSEDED 2026-10-26 by `parse_strt_end_key`: this keeps only the low 16
bits (the 64 KB page bug) and misreads an end whose low bytes hold an escaped
02/03/04. No production caller; kept for tests/test_5a_protocol.py.
Extract the event-end offset from the STRT record in an A5 response payload.
The first A5 response (the probe response, or the first chunk for events
+14
View File
@@ -544,6 +544,15 @@ class Event:
pretrig_samples: Optional[int] = None # from STRT record: pre-trigger sample count
rectime_seconds: Optional[int] = None # from STRT record: record duration (seconds)
# Sensor self-check traces keyed by channel label — the short diagnostic
# waveforms the unit records when it pulses each sensor before monitoring
# (geophone ring-downs + a mic pulse train). Decoded from the binary by
# the per-series decoder (minimateplus.sensor_check / micromate.sensor_check)
# and carried here so the .h5 writer can persist them device-agnostically.
# Raw ADC counts; the source series' scale differs but the trace is a
# shape diagnostic (rendered fit-to-box). None when absent.
sensor_check: Optional[dict] = None # {"Tran": [...], ..., "MicL": [...]}
# ── Debug / introspection ─────────────────────────────────────────────────
# Raw 210-byte waveform record bytes, set when debug mode is active.
# Exposed by the SFM server via ?debug=true so field layouts can be verified.
@@ -651,3 +660,8 @@ class MonitorStatus:
battery_v: Optional[float] = None # Battery voltage in volts ✅
memory_total: Optional[int] = None # Total flash memory in bytes ✅
memory_free: Optional[int] = None # Free flash memory in bytes ✅
# The raw flag byte `is_monitoring` is derived from: section[1] = data[12].
# Measured: 0x00 idle, 0x10 monitoring. None when the section is too short
# to hold it. Kept raw so a caller can refuse a value never measured,
# where `is_monitoring` reads anything but 0x10 as idle.
state_flag: Optional[int] = None
+334 -403
View File
@@ -29,14 +29,12 @@ from .framing import (
S3Frame,
S3FrameParser,
build_bw_frame,
build_5a_frame,
build_bw_write_frame,
waveform_key_params,
token_params,
bulk_waveform_params,
bulk_waveform_term_params,
bulk_waveform_term_v2,
parse_strt_end_offset,
parse_strt_end_key,
unescape_reply,
build_5a_request,
POLL_PROBE,
POLL_DATA,
SESSION_RESET,
@@ -123,23 +121,49 @@ DATA_LENGTHS: dict[int, int] = {
# NOT handled here — requires specialised read logic.
}
# SUB 5A (BULK_WAVEFORM_STREAM) protocol constants.
#
# 2026-05-01 minimal-fix: the chunk-counter walk is now bounded by the event's
# `end_offset` extracted from the STRT record at data[23:27] of the probe
# response. Without this bound the loop kept asking for chunks past the event
# end and the device responded with post-event circular-buffer garbage,
# corrupting reconstructed Blastware files for events ≥ 2 sec.
#
# We keep the OLD 0x0400 chunk step here (BW actually uses 0x0200 — see §7.8.5
# of the protocol reference for the corrected understanding) because the
# existing blastware_file.py builder relies on the 0x0400-step frame structure
# to produce valid files. Switching to BW's 0x0200 step is a separate task
# that also requires updating the file builder.
# BW-exact protocol values (v0.14.0). Verified against 4-27-26 + 5-1-26 captures.
_BULK_CHUNK_OFFSET = 0x1002 # offset_word for probe + all chunk requests
_BULK_TERM_OFFSET = 0x005A # offset_word for the legacy terminator (fallback only)
_BULK_COUNTER_STEP = 0x0200 # chunk counter increment (matches chunk payload size)
# SUB 5A (BULK_WAVEFORM_STREAM) walk constants. A 5A request is a read of a
# LENGTH at a 32-bit ADDRESS (measured 2026-10-26 against Blastware; see
# read_bulk_waveform_stream and framing.build_5a_request).
_BULK_TERM_OFFSET = 0x005A # TERM length when the end is unknown (legacy fallback only)
_BULK_COUNTER_STEP = 0x0200 # bytes per chunk read, and the step between addresses
# A sanity bound on the size STRT claims, not a measured limit: BE units report
# 983,026 bytes of memory (SUB 1C) and the largest archived event is ~850 KB. A
# claim past this is a misread STRT, refused before walking megabytes of garbage.
_BULK_MAX_EVENT_BYTES = 0x400000 # 4 MiB
# Config writes (issue #46, measured on every Blastware write since February 2026).
_COMPLIANCE_CHUNK = 0x0200
# The two bytes after a block's N header bytes, when the read returned only N:
# Blastware's own, constant on record -- event index 02 00, trigger 00 00. The
# unit evidently does not check them (they are no CRC, and the compliance
# image's went out stale, unchanged across two different sends).
_WRITE_TAIL = {SUB_EVENT_INDEX_WRITE: b"\x02\x00", SUB_TRIGGER_CONFIG_WRITE: b"\x00\x00",
SUB_WAVEFORM_DATA_WRITE: b"\x00\x00", SUB_COMPLIANCE_WRITE: b"\x00\x00",
SUB_CALL_HOME_WRITE: b"\x00\x00"}
def write_image(sub: int, data: bytes) -> bytes:
"""The whole block a write sends: `data` unescaped, N + 2 bytes.
A config block starts with its own length N (uint16 BE) and is written as N
bytes plus two -- on every Blastware write on record. `data` may be the
block as a read returned it (N bytes, or N + 2) and may still hold the
parser's kept escape bytes (10 02 / 10 03 / 10 04), which come out here.
Anything else is refused before a byte is sent: a block one byte longer than
its header says is what an edit beside a kept escape byte leaves behind.
"""
image = unescape_reply(bytes(data))
if len(image) < 2:
raise ValueError(f"write SUB 0x{sub:02X}: {len(image)} bytes is not a whole block")
n = int.from_bytes(image[:2], "big")
if len(image) == n:
image += _WRITE_TAIL[sub]
elif len(image) != n + 2:
raise ValueError(
f"write SUB 0x{sub:02X}: {len(image)} bytes, but its header says {n} (+ 2) -- "
"not a whole block (a stray byte?); nothing sent")
return image
# Default timeout values (seconds).
# MiniMate Plus is a slow device — keep these generous.
@@ -212,7 +236,7 @@ class MiniMateProtocol:
ProtocolError: if either POLL step fails.
"""
log.debug("startup: draining boot string")
self._drain_boot_string()
booting = self._drain_boot_string()
# Send session-reset signal (ACK+ETX) before the first POLL probe.
# Confirmed from 4-8-26 BW TX captures: Blastware always sends this
@@ -223,10 +247,17 @@ class MiniMateProtocol:
log.debug("startup: POLL probe")
self._send(POLL_PROBE)
probe_rsp = self._recv_one(
expected_sub=_expected_rsp_sub(SUB_POLL),
timeout=self._recv_timeout,
)
try:
# A banner already drained means the unit is booting: a short wait,
# then the re-poll loop, rather than the full timeout.
probe_rsp = self._await_poll_or_boot(
self._BOOT_POLL_S if booting else self._recv_timeout)
except TimeoutError:
if not booting:
raise
probe_rsp = None
if probe_rsp is None:
probe_rsp = self._poll_until_booted()
log.debug(
"startup: POLL probe response page_key=0x%04X", probe_rsp.page_key
)
@@ -293,6 +324,35 @@ class MiniMateProtocol:
log.debug("read SUB=0x%02X: received %d data bytes", sub, len(data_rsp.data))
return data_rsp.data
def wake(self, attempt_s: float = 5.0, deadline_s: float = 60.0) -> S3Frame:
"""SESSION_RESET + POLL, re-sent every `attempt_s` until the unit answers.
A monitoring unit ignores everything until SESSION_RESET (2026-04-08), and
right after a start it runs its sensor check (~30 s, Brian, 2026-10-26).
BE9441 left a POLL sent 2 s after a start unanswered and never answered
it later, so one try with a long wait is not enough: ask again until the
unit answers or `deadline_s` passes. A read -- nothing but SESSION_RESET
and POLL is sent. Returns the POLL data frame.
"""
deadline = time.monotonic() + deadline_s
while True:
self._parser.reset()
self._send(SESSION_RESET)
self._send(POLL_PROBE)
try:
self._recv_one(expected_sub=_expected_rsp_sub(SUB_POLL), timeout=attempt_s)
break
except TimeoutError:
if time.monotonic() >= deadline:
raise TimeoutError(
f"the unit did not answer a POLL within {deadline_s:.0f} s "
f"(asked every {attempt_s:.0f} s)") from None
self._send(SESSION_RESET)
self._send(POLL_DATA)
rsp = self._recv_one(expected_sub=_expected_rsp_sub(SUB_POLL), timeout=attempt_s)
self._drain_boot_string(drain_ms=300) # a late answer to an earlier try, if any
return rsp
def poll(self) -> S3Frame:
"""
Send a single POLL (SUB 5B) probe+data cycle and return the data response.
@@ -358,7 +418,9 @@ class MiniMateProtocol:
self._send(build_bw_frame(SUB_EVENT_INDEX, length))
data_rsp = self._recv_one(expected_sub=rsp_sub)
raw = data_rsp.data[11 : 11 + length]
# Unescaped first (2026-10-27): a 02/03/04 inside the block arrives as
# 10 0X and the parser keeps both, so a slice by length came up short.
raw = unescape_reply(data_rsp.data)[11 : 11 + length]
log.debug("read_event_index: got %d bytes", len(raw))
return raw
@@ -490,7 +552,7 @@ class MiniMateProtocol:
self._send(build_bw_frame(SUB_WAVEFORM_DATA, length))
data_rsp = self._recv_one(expected_sub=rsp_sub)
raw = data_rsp.data[11:]
raw = unescape_reply(data_rsp.data)[11:] # unescaped, as read_event_index
log.debug("read_waveform_data_raw: got %d bytes", len(raw))
return raw
@@ -538,53 +600,47 @@ class MiniMateProtocol:
max_chunks: int = 256, # safety cap only; loop is bounded by end_offset
include_terminator: bool = False,
extra_chunks_after_metadata: int = 1, # DEPRECATED — no-op
strict: bool = False,
) -> list[S3Frame]:
"""
Download the SUB 5A (BULK_WAVEFORM_STREAM) A5 frames for one event using
Blastware's exact protocol. REWRITTEN 2026-05-02 (v0.14.0).
Algorithm (matches BW captures across 2-sec / 3-sec / event-2):
strict: the stream must arrive whole, or this raises ProtocolError -- a
missing STRT, a metadata page or chunk with no reply, a mid-stream
terminator, the chunk cap, or no TERM reply. The one-event download uses
it: a short event must never be stored (BE9441 rebooted mid-download on
2026-10-25 and its partial event was kept). Without strict the legacy
tolerance stands: an early end proceeds to TERM and returns what arrived.
1. Probe
- For events at start_key[2:4] = 0x0000 (first event after erase
/ wrap): probe at counter=0x0000 with full key in params.
- For continuation events (start_key[2:4] != 0): first chunk at
counter = start_key[2:4] + 0x0046; acts as both probe and
first sample chunk; response carries STRT.
The walk (measured 2026-10-26: Blastware downloading all 8 of BE9441's
events, four crossing a 64 KB page -- tests/test_5a_blastware_walk.py
rebuilds its requests byte for byte):
2. Parse end_offset from STRT record at data[23:27] of the probe response.
1. Read 0x200 bytes at the event's own 32-bit address (the key). The
reply carries STRT, whose end key is the full 32-bit address where
the event ends.
2. Read 0x200 bytes at each next address, +0x200 at a time, as plain
32-bit numbers -- crossing into the next 64 KB page needs nothing
special -- while the whole chunk fits before the end.
3. TERM: read the remainder (end - next boundary) at the next boundary.
Its reply carries the event's tail and the file footer.
3. Read two fixed metadata pages at counter=0x1002 and counter=0x1004
— global session metadata (Project / Client / User Name / Seis Loc
/ Extended Notes ASCII strings). Event 1 only; continuation
events skip these (BW caches them across the session).
4. Walk sample chunks at 0x0200 increments, starting from 0x0600 for
event 1 or `start + 0x0046 + 0x0200` for continuation events.
Stop when `next_chunk + 0x0200 > end_offset`.
5. Send TERM frame with offset_word and params computed by
`bulk_waveform_term_v2(key4, end_offset, last_chunk_counter)`.
The TERM response contains the partial last chunk (residual =
end_offset - next_boundary) including the 26-byte 0e 08 file
footer.
The first event on a unit reads 0x0000, 0x0200, 0x0400, 0x0600, ...: the
"metadata pages at 0x1002 / 0x1004" of the earlier model were its chunks
at 0x0200 and 0x0400, escaped (`10 02 00`, `10 04 00`). That model's
16-bit counter could not leave the key's page -- the 64 KB page bug.
Returns:
List of S3Frame objects from each A5 response (probe, metadata
pages, sample chunks, optional TERM response). Caller passes
`include_terminator=True` (e.g. write_blastware_file) to keep the
TERM response in the list — it's required to reconstruct the
file footer.
The A5 frames in order (first chunk, chunks, and with
`include_terminator=True` the TERM reply, which write_blastware_file
needs for the footer).
Deprecated kwargs:
stop_after_metadata: legacy "Project:"-string-based stop condition.
No-op under the BW-exact walk; the loop is
deterministically bounded by end_offset from
STRT. Accepted for backward compat.
extra_chunks_after_metadata: same.
Deprecated kwargs (no-ops): stop_after_metadata, extra_chunks_after_metadata.
Raises:
ProtocolError: on timeout / bad checksum / unexpected SUB.
ProtocolError: on timeout / bad checksum / unexpected SUB, and in
strict mode on any early end.
"""
if len(key4) != 4:
raise ValueError(f"waveform key must be 4 bytes, got {len(key4)}")
@@ -598,38 +654,15 @@ class MiniMateProtocol:
rsp_sub = _expected_rsp_sub(SUB_BULK_WAVEFORM) # 0xA5
frames_data: list[S3Frame] = []
start = int.from_bytes(key4, "big")
start_offset = (key4[2] << 8) | key4[3]
is_event_1 = (start_offset == 0)
def request(address: int, length: int) -> None:
self._send(build_5a_request(address, length))
self._parser.reset()
# ── Step 1: probe / first chunk ──────────────────────────────────────
if is_event_1:
probe_counter = 0
probe_params = bulk_waveform_params(key4, 0, is_probe=True)
log.debug("5A probe (event-1) key=%s counter=0x0000", key4.hex())
else:
# Continuation events: first 5A request lands at counter = key[2:4]
# (i.e. the address of the off=0x46 WAVEHDR record returned by 1F).
# The probe response carries STRT at byte 17 with end_offset.
#
# Confirmed 2026-05-04 from 5-1-26 "copy 2nd address" capture
# (BW probes counter=0x2238 with key=01112238, STRT@17 end=0x417E)
# and 5-4-26 BW captures (2-sec event probes counter=0x2238).
#
# The earlier "+0x46" formula in the doc came from calling
# start_key the BOUNDARY (off=0x2C) key, but the iteration walk
# uses 1F's off=0x46 key as cur_key, which already incorporates
# the +0x46 offset relative to the boundary. Adding it again
# caused the probe to overshoot, miss STRT, and run uncapped.
probe_counter = start_offset
probe_params = bulk_waveform_params(key4, probe_counter)
log.debug(
"5A probe (event-N) key=%s counter=0x%04X",
key4.hex(), probe_counter,
)
self._send(build_5a_frame(_BULK_CHUNK_OFFSET, probe_params))
self._parser.reset()
# ── Step 1: the event's first chunk; its reply carries STRT ──────────
log.debug("5A first chunk key=%s", key4.hex())
request(start, _BULK_COUNTER_STEP)
try:
rsp = self._recv_one(expected_sub=rsp_sub, reset_parser=False)
except TimeoutError:
@@ -638,102 +671,79 @@ class MiniMateProtocol:
key4.hex(), self._parser.bytes_fed,
)
raise
frames_data.append(rsp)
log.debug("5A A5[0] (probe) page_key=0x%04X %d bytes",
rsp.page_key, len(rsp.data))
log.debug("5A A5[0] (probe) page_key=0x%04X %d bytes", rsp.page_key, len(rsp.data))
# ── Step 2: parse STRT end_offset from probe response ────────────────
end_offset = parse_strt_end_offset(rsp.data)
if end_offset is None:
# ── Step 2: where the event ends -- STRT's full 32-bit end key ───────
end = parse_strt_end_key(rsp.data)
if end is None and strict:
raise ProtocolError(
f"5A probe for {key4.hex()} carried no STRT record, so the event's end "
"is unknown -- not downloaded")
if end is not None and end <= start:
if strict:
raise ProtocolError(
f"5A STRT for {key4.hex()} says the event ends at 0x{end:08X}, at or "
"before its start -- not downloaded")
log.warning("5A STRT end 0x%08X is not after the start 0x%08X -- ignored", end, start)
end = None
if end is not None and end - start < _BULK_COUNTER_STEP:
# The walk's first read is a whole chunk, so a smaller event cannot be
# bounded -- and no event is that small (the header alone is longer).
raise ProtocolError(
f"5A STRT for {key4.hex()} says the event is {end - start} bytes, less than "
"one 0x200 chunk -- a misread STRT; not downloaded")
if end is not None and end - start > _BULK_MAX_EVENT_BYTES:
raise ProtocolError(
f"5A STRT for {key4.hex()} says the event is {end - start:,} bytes, more than "
f"any unit holds ({_BULK_MAX_EVENT_BYTES:,}) -- a misread STRT; not downloaded")
have_end = end is not None
if not have_end:
log.warning(
"5A probe response did not contain a STRT record; "
"5A probe response did not contain a usable STRT record; "
"cannot bound chunk loop — falling back to max_chunks=%d cap",
max_chunks,
)
end_offset = 0xFFFF # impossible value → loop runs to max_chunks
end = start + (max_chunks + 2) * _BULK_COUNTER_STEP # the cap bounds the loop
else:
log.info(
"5A STRT start_offset=0x%04X end_offset=0x%04X size=0x%04X",
start_offset, end_offset, end_offset - start_offset,
)
log.info("5A STRT start=0x%08X end=0x%08X size=0x%X", start, end, end - start)
# With the end known, STRT bounds the walk and the cap must not cut it short:
# a histogram can be several hundred KB (2,545 of 63,500 in the DL2 archive
# exceed the 128-chunk / ~66 KB a caller's cap allowed). The cap still
# bounds a walk whose end is unknown.
chunk_cap = max(max_chunks, (end - start) // _BULK_COUNTER_STEP) if have_end else max_chunks
# ── Step 3: metadata pages 0x1002 + 0x1004 (event 1 only) ────────────
# Confirmed from BW captures: BW reads these two fixed device-buffer
# pages immediately after the probe for events at start_key[2:4]=0.
# Continuation events skip them (BW caches across the session).
# Their content is global compliance-setup metadata: Project, Client,
# User Name, Seis Loc, Extended Notes.
if is_event_1:
for meta_counter in (0x1002, 0x1004):
# Metadata page params have an extra trailing 0x00 byte
# (12-byte params instead of 11) — empirical from BW captures.
# Checksum-neutral but matches BW byte-for-byte.
meta_params = bytes([
0x00,
key4[0], key4[1],
(meta_counter >> 8) & 0xFF,
meta_counter & 0xFF,
0, 0, 0, 0, 0, 0, 0,
])
log.debug("5A metadata page counter=0x%04X", meta_counter)
self._send(build_5a_frame(_BULK_CHUNK_OFFSET, meta_params))
self._parser.reset()
try:
meta_rsp = self._recv_one(
expected_sub=rsp_sub, reset_parser=False, timeout=10.0,
)
except TimeoutError:
log.warning(
"5A metadata page 0x%04X TIMED OUT — continuing",
meta_counter,
)
continue
frames_data.append(meta_rsp)
log.debug(
"5A meta@0x%04X page_key=0x%04X %d bytes",
meta_counter, meta_rsp.page_key, len(meta_rsp.data),
)
# ── Step 4: sample chunk loop, bounded by end_offset ─────────────────
# Sample chunks start at:
# event 1: counter = 0x0600
# event N (>0): counter = probe_counter + 0x0200
# (probe was the first sample chunk)
if is_event_1:
counter = 0x0600
else:
counter = probe_counter + _BULK_COUNTER_STEP
last_chunk_counter: Optional[int] = (
probe_counter if not is_event_1 else None
)
# ── Step 3: chunks at +0x200, plain 32-bit addresses ─────────────────
address = start + _BULK_COUNTER_STEP
last = start
chunks_fetched = 0
while chunks_fetched < max_chunks:
# Stop when next chunk would straddle the event end.
if counter + _BULK_COUNTER_STEP > end_offset:
while chunks_fetched < chunk_cap:
# Stop when the next chunk would straddle the event end.
if address + _BULK_COUNTER_STEP > end:
log.debug(
"5A chunk loop done at counter=0x%04X (end=0x%04X); "
"%d chunks fetched",
counter, end_offset, chunks_fetched,
"5A chunk loop done at 0x%08X (end=0x%08X); %d chunks fetched",
address, end, chunks_fetched,
)
break
params = bulk_waveform_params(key4, counter)
log.debug("5A chunk #%d counter=0x%04X", chunks_fetched + 1, counter)
self._send(build_5a_frame(_BULK_CHUNK_OFFSET, params))
self._parser.reset()
log.debug("5A chunk #%d address=0x%08X", chunks_fetched + 1, address)
request(address, _BULK_COUNTER_STEP)
try:
rsp = self._recv_one(
expected_sub=rsp_sub, reset_parser=False, timeout=10.0,
)
except TimeoutError:
except TimeoutError as exc:
raw = self._parser.bytes_fed
log.warning(
"5A TIMEOUT chunk=%d counter=0x%04X raw_bytes=%d",
chunks_fetched + 1, counter, raw,
"5A TIMEOUT chunk=%d address=0x%08X raw_bytes=%d",
chunks_fetched + 1, address, raw,
)
if strict:
raise TimeoutError(
f"5A stream ended early: no reply for the chunk at 0x{address:08X}; the "
f"event ends at 0x{end:08X} ({chunks_fetched} chunk(s) received) "
"-- the event was not kept") from exc
if raw > 0 and frames_data:
log.warning(
"5A unexpected end-of-stream — proceeding to TERM",
@@ -748,46 +758,53 @@ class MiniMateProtocol:
if rsp.page_key == 0x0000:
# Device terminated mid-stream unexpectedly.
if strict:
raise ProtocolError(
f"5A stream ended early: the unit sent its terminator at 0x{address:08X}, "
f"before the event's end 0x{end:08X} -- the event was not kept")
log.warning(
"5A unexpected page_key=0x0000 mid-stream at counter=0x%04X",
counter,
"5A unexpected page_key=0x0000 mid-stream at address=0x%08X",
address,
)
if include_terminator:
frames_data.append(rsp)
return frames_data
frames_data.append(rsp)
last_chunk_counter = counter
counter += _BULK_COUNTER_STEP
last = address
address += _BULK_COUNTER_STEP
chunks_fetched += 1
else:
if strict:
raise ProtocolError(
f"5A reached the {chunk_cap}-chunk cap at 0x{address:08X} before the "
f"event's end 0x{end:08X} -- the event was not kept")
log.warning(
"5A reached max_chunks=%d at counter=0x%04X (end=0x%04X)",
max_chunks, counter, end_offset,
"5A reached max_chunks=%d at address=0x%08X (end=0x%08X)",
chunk_cap, address, end,
)
# ── Step 5: TERM with proper end_offset-derived formula ──────────────
if last_chunk_counter is None or end_offset == 0xFFFF:
# No STRT or no chunks fetched — fall back to legacy TERM.
log.warning(
"5A using legacy TERM (offset_word=0x005A); "
"end_offset unavailable or no chunks fetched",
)
legacy_counter = (last_chunk_counter or probe_counter) + _BULK_COUNTER_STEP
term_offset_word = _BULK_TERM_OFFSET # 0x005A
term_params = bulk_waveform_term_params(key4, legacy_counter)
# ── Step 4: TERM -- the remainder, from the next boundary ───────────
boundary = last + _BULK_COUNTER_STEP
if have_end:
term_length = end - boundary
if not 0 <= term_length < _BULK_COUNTER_STEP:
# Only after an early end (the legacy tolerance): what is left is not a
# tail but most of the event, and a TERM for it is no TERM at all.
if strict:
raise ProtocolError(
f"5A TERM for {key4.hex()} would read 0x{term_length:X} bytes from "
f"0x{boundary:08X}, not a tail -- the event was not kept")
log.warning("5A stream ended 0x%X bytes before the event's end; no TERM sent",
term_length)
return frames_data
log.debug("5A TERM address=0x%08X length=0x%04X end=0x%08X",
boundary, term_length, end)
else:
term_offset_word, term_params = bulk_waveform_term_v2(
key4, end_offset, last_chunk_counter,
)
log.debug(
"5A TERM offset_word=0x%04X params[2:4]=%s end=0x%04X "
"last_chunk=0x%04X",
term_offset_word, term_params[2:4].hex(),
end_offset, last_chunk_counter,
)
term_length = _BULK_TERM_OFFSET # legacy: no STRT, so no remainder known
log.warning("5A using legacy TERM (length 0x%04X); end unknown", term_length)
self._send(build_5a_frame(term_offset_word, term_params))
self._send(build_5a_request(boundary, term_length))
try:
term_rsp = self._recv_one(expected_sub=rsp_sub, timeout=10.0)
log.info(
@@ -796,7 +813,11 @@ class MiniMateProtocol:
)
if include_terminator:
frames_data.append(term_rsp)
except TimeoutError:
except TimeoutError as exc:
if strict:
raise TimeoutError(
"5A stream ended early: no reply to the TERM request, which carries the "
"event's tail and footer -- the event was not kept") from exc
log.warning("5A no TERM response (timeout)")
return frames_data
@@ -1029,208 +1050,66 @@ class MiniMateProtocol:
self._send(frame)
return self.recv_write_ack(expected_sub=rsp_sub)
def write_event_index(self, data: bytes) -> S3Frame:
"""
Send a SUB 68 (EVENT_INDEX_WRITE) frame and await the confirm ack (SUB 97).
Offset formula: data[1] + 2 — confirmed from 3-11-26 BW TX capture frame 102.
The write payload has a 2-byte header [0x00][length] where data[1] encodes
the length of the meaningful payload; offset = data[1] + 2.
Example from capture:
data[0:4] = 00 58 09 00 (data[1]=0x58=88 → offset=0x5A=90)
data length = 91, offset = 90
Write sequence fragment:
68 (data) → device acks with SUB 0x97
73 (confirm) → device acks with SUB 0x8C
Callers should call write_confirm(SUB_WRITE_CONFIRM_B) after this.
Args:
data: Raw event-index payload bytes to write to the device.
Must be at least 2 bytes. data[1] must contain the length field.
Returns:
The SUB 0x97 ack frame.
Raises:
ProtocolError: on timeout or wrong response SUB.
ValueError: if data is shorter than 2 bytes.
"""
if len(data) < 2:
raise ValueError(f"event index write data must be at least 2 bytes, got {len(data)}")
rsp_sub = _expected_rsp_sub(SUB_EVENT_INDEX_WRITE) # 0xFF - 0x68 = 0x97
offset = data[1] + 2
frame = build_bw_write_frame(SUB_EVENT_INDEX_WRITE, data, offset=offset)
log.debug(
"write_event_index: %d bytes data[1]=0x%02X offset=0x%04X rsp_sub=0x%02X",
len(data), data[1], offset, rsp_sub,
)
def _write_block(self, sub: int, data: bytes, params: bytes = bytes(10)) -> S3Frame:
"""Send one config block as a write and return its ack (0xFF - sub)."""
image = write_image(sub, data)
frame = build_bw_write_frame(sub, image, params=params)
log.debug("write SUB=0x%02X: %d-byte image", sub, len(image))
self._send(frame)
return self.recv_write_ack(expected_sub=rsp_sub)
return self.recv_write_ack(expected_sub=_expected_rsp_sub(sub))
def write_event_index(self, data: bytes) -> S3Frame:
"""SUB 68: write the event-index block (as SUB 08 read it). Ack 0x97;
callers follow with write_confirm(SUB_WRITE_CONFIRM_B). See write_image."""
return self._write_block(SUB_EVENT_INDEX_WRITE, data)
def write_waveform_data(self, data: bytes) -> S3Frame:
"""
Send a SUB 69 (WAVEFORM_DATA_WRITE) frame and await the confirm ack (SUB 96).
Offset formula: data[1] + 2 — same pattern as write_event_index().
Confirmed from 3-11-26 BW TX capture frame 110:
data[0:4] = 00 c8 08 00 (data[1]=0xC8=200 → offset=0xCA=202)
data length = 204, offset = 202
Write sequence fragment:
69 (data) → device acks with SUB 0x96
74 (confirm) → device acks with SUB 0x8B
72 (confirm) → device acks with SUB 0x8D
Callers should call write_confirm(SUB_WRITE_CONFIRM_C) then
write_confirm(SUB_WRITE_CONFIRM_A) after this.
Args:
data: Raw waveform-data payload bytes to write.
Must be at least 2 bytes. data[1] must contain the length field.
Returns:
The SUB 0x96 ack frame.
Raises:
ProtocolError: on timeout or wrong response SUB.
ValueError: if data is shorter than 2 bytes.
"""
if len(data) < 2:
raise ValueError(f"waveform data write payload must be at least 2 bytes, got {len(data)}")
rsp_sub = _expected_rsp_sub(SUB_WAVEFORM_DATA_WRITE) # 0xFF - 0x69 = 0x96
offset = data[1] + 2
frame = build_bw_write_frame(SUB_WAVEFORM_DATA_WRITE, data, offset=offset)
log.debug(
"write_waveform_data: %d bytes data[1]=0x%02X offset=0x%04X rsp_sub=0x%02X",
len(data), data[1], offset, rsp_sub,
)
self._send(frame)
return self.recv_write_ack(expected_sub=rsp_sub)
"""SUB 69: write the waveform-data block (as SUB 09 read it). Ack 0x96;
callers follow with write_confirm C then A. See write_image."""
return self._write_block(SUB_WAVEFORM_DATA_WRITE, data)
def write_compliance_config_raw(self, data: bytes) -> None:
"""SUB 71: write the compliance image in addressed chunks, then confirm (72).
Measured: the image is 2,092 bytes (its header N = 2,090, plus 2), sent as
512-byte chunks with the chunk's address at params[2:4] -- 0x0000, 0x0200,
0x0400, 0x0600, then the 44-byte rest at 0x0800 -- each acked 0x8E, then
SUB 72 (ack 0x8D). Blastware 10.74 on BE9441 (2026-10-26), byte for byte.
March 2026's Blastware sent 1,024-byte chunks the same way; the units took
both. (Retracted: "exactly 3 chunks, offset 0x1004, params 00 00 00 10 04"
-- the length 0x0400 and address 0x0400, read with their escape bytes.)
"""
Send the SUB 71 (COMPLIANCE_WRITE) 3-chunk sequence and final confirm.
The full compliance config payload (~2128 bytes) is split into exactly 3
chunks with hardcoded boundaries and params confirmed from the 3-11-26 BW
TX capture (frames 104–108):
Chunk 1 — first 1027 bytes:
offset=0x1004 params=bytes(10)
device acks SUB 0x8E
Chunk 2 — next 1055 bytes:
offset=0x1004 params=b'\\x00\\x00\\x00\\x00\\x10\\x04' + b'\\x00'*4
device acks SUB 0x8E
Chunk 3 — remaining bytes:
offset=0x002C params=b'\\x00\\x00\\x08' + b'\\x00'*7
device acks SUB 0x8E
Confirm — SUB 72 (zero data):
device acks SUB 0x8D
The total write payload should be at least 1027+1055=2082 bytes; chunk 3
carries everything after offset 2082 (typically ~46 bytes for a 2128-byte
config).
Args:
data: Raw compliance config bytes to write. Must be at least 2082 bytes.
Raises:
ValueError: if data is too short to fill chunks 1 and 2.
ProtocolError: on timeout or wrong response SUB from any chunk.
"""
_CHUNK1_SIZE = 1027
_CHUNK2_SIZE = 1055
_CHUNK1_OFFSET = 0x1004
_CHUNK2_OFFSET = 0x1004
_CHUNK3_OFFSET = 0x002C
_CHUNK1_PARAMS = bytes(10)
_CHUNK2_PARAMS = bytes([0x00, 0x00, 0x00, 0x10, 0x04, 0x00, 0x00, 0x00, 0x00, 0x00])
_CHUNK3_PARAMS = bytes([0x00, 0x00, 0x08, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00, 0x00])
min_size = _CHUNK1_SIZE + _CHUNK2_SIZE
if len(data) < min_size:
raise ValueError(
f"Compliance write data too short: {len(data)} bytes, "
f"need at least {min_size} (chunk1={_CHUNK1_SIZE} + chunk2={_CHUNK2_SIZE})"
)
rsp_sub = _expected_rsp_sub(SUB_COMPLIANCE_WRITE) # 0xFF - 0x71 = 0x8E
chunk1 = data[:_CHUNK1_SIZE]
chunk2 = data[_CHUNK1_SIZE : _CHUNK1_SIZE + _CHUNK2_SIZE]
chunk3 = data[_CHUNK1_SIZE + _CHUNK2_SIZE :]
chunks = [
(1, chunk1, _CHUNK1_OFFSET, _CHUNK1_PARAMS),
(2, chunk2, _CHUNK2_OFFSET, _CHUNK2_PARAMS),
(3, chunk3, _CHUNK3_OFFSET, _CHUNK3_PARAMS),
]
for chunk_num, chunk_data, chunk_offset, chunk_params in chunks:
frame = build_bw_write_frame(
SUB_COMPLIANCE_WRITE,
chunk_data,
offset=chunk_offset,
params=chunk_params,
)
log.debug(
"write_compliance_config_raw: chunk %d %d bytes "
"offset=0x%04X params=%s",
chunk_num, len(chunk_data), chunk_offset, chunk_params.hex(),
)
image = write_image(SUB_COMPLIANCE_WRITE, data)
rsp_sub = _expected_rsp_sub(SUB_COMPLIANCE_WRITE)
for addr in range(0, len(image), _COMPLIANCE_CHUNK):
params = bytes([0x00, 0x00, (addr >> 8) & 0xFF, addr & 0xFF]) + bytes(6)
frame = build_bw_write_frame(SUB_COMPLIANCE_WRITE,
image[addr:addr + _COMPLIANCE_CHUNK], params=params)
log.debug("write_compliance_config_raw: chunk at 0x%04X", addr)
self._send(frame)
self.recv_write_ack(expected_sub=rsp_sub)
log.debug("write_compliance_config_raw: chunk %d acked", chunk_num)
# Final confirm (SUB 72)
log.debug("write_compliance_config_raw: sending confirm (SUB 0x72)")
self.write_confirm(SUB_WRITE_CONFIRM_A)
log.debug("write_compliance_config_raw: done")
def write_trigger_config(self, data: bytes) -> S3Frame:
"""SUB 82: write the trigger block (as SUB 0x2E read it). Ack 0x7D;
callers follow with write_confirm(SUB_TRIGGER_CONFIRM). See write_image."""
return self._write_block(SUB_TRIGGER_CONFIG_WRITE, data)
def read_trigger_config(self) -> bytes:
"""SUB 0x2E two-step read: the 26-byte trigger block that SUB 82 writes.
Blastware reads it before writing it (BE9441, 2026-10-26). Its byte 5
differs by unit and session (01 / 03 / 04 on record) -- so a block copied
from another unit, as apply_config once wrote, changes a setting.
Returns the block unescaped (data[11:] after unescape_reply).
"""
Send a SUB 82 (TRIGGER_CONFIG_WRITE) frame and await the confirm ack (SUB 7D).
Offset formula: data[1] + 2 — same pattern as write_event_index().
Confirmed from 3-11-26 BW TX capture frame 108:
data[0:4] = 00 1a d5 00 (data[1]=0x1A=26 → offset=0x1C=28)
data length = 29, offset = 28
Write sequence fragment:
82 (data) → device acks with SUB 0x7D
83 (confirm) → device acks with SUB 0x7C
Callers should call write_confirm(SUB_TRIGGER_CONFIRM) after this.
Args:
data: Raw trigger-config payload bytes to write.
Must be at least 2 bytes. data[1] must contain the length field.
Returns:
The SUB 0x7D ack frame.
Raises:
ProtocolError: on timeout or wrong response SUB.
ValueError: if data is shorter than 2 bytes.
"""
if len(data) < 2:
raise ValueError(f"trigger config write payload must be at least 2 bytes, got {len(data)}")
rsp_sub = _expected_rsp_sub(SUB_TRIGGER_CONFIG_WRITE) # 0xFF - 0x82 = 0x7D
offset = data[1] + 2
frame = build_bw_write_frame(SUB_TRIGGER_CONFIG_WRITE, data, offset=offset)
log.debug(
"write_trigger_config: %d bytes data[1]=0x%02X offset=0x%04X rsp_sub=0x%02X",
len(data), data[1], offset, rsp_sub,
)
self._send(frame)
return self.recv_write_ack(expected_sub=rsp_sub)
rsp_sub = _expected_rsp_sub(SUB_UNKNOWN_2E)
length = DATA_LENGTHS[SUB_UNKNOWN_2E]
self._send(build_bw_frame(SUB_UNKNOWN_2E, 0))
self._recv_one(expected_sub=rsp_sub)
self._send(build_bw_frame(SUB_UNKNOWN_2E, length))
data_rsp = self._recv_one(expected_sub=rsp_sub)
return unescape_reply(data_rsp.data)[11:11 + length]
# ── Call home config (SUBs 0x2C / 0x7E / 0x7F) ──────────────────────────
@@ -1294,20 +1173,13 @@ class MiniMateProtocol:
ValueError: if data is not exactly 127 bytes or lacks expected header.
ProtocolError: on timeout or wrong response SUB.
"""
if len(data) < 2:
raise ValueError(f"call home write payload must be at least 2 bytes, got {len(data)}")
rsp_sub_write = _expected_rsp_sub(SUB_CALL_HOME_WRITE) # 0xFF - 0x7E = 0x81
rsp_sub_confirm = _expected_rsp_sub(SUB_CALL_HOME_CONFIRM) # 0xFF - 0x7F = 0x80
# Offset formula: data[1] + 2 (same pattern as other single-chunk writes)
offset = data[1] + 2 # 0x7C + 2 = 0x7E = 126
frame = build_bw_write_frame(SUB_CALL_HOME_WRITE, data, offset=offset)
log.debug(
"write_call_home_config: %d bytes data[1]=0x%02X offset=0x%04X",
len(data), data[1], offset,
)
self._send(frame)
self.recv_write_ack(expected_sub=rsp_sub_write)
# 2026-10-27 (#46): the read payload holds the parser's kept escape bytes
# (num_retries 3 arrives as 10 03); write_image removes them, so the
# 127-byte "read + 00 00" goes out as its 126-byte image (N = 0x7C, + 2),
# escaped like every request. No Blastware call-home write is on record
# here to compare against -- inferred from the 77 other write frames.
self._write_block(SUB_CALL_HOME_WRITE, data)
log.debug("write_call_home_config: write acked; sending confirm 0x7F")
confirm_frame = build_bw_write_frame(SUB_CALL_HOME_CONFIRM, b"")
@@ -1523,10 +1395,10 @@ class MiniMateProtocol:
def _validate_frame(frame: S3Frame, expected_sub: Optional[int]) -> None:
"""Validate SUB; log but do not raise on bad checksum.
S3 response checksums frequently fail SUM8 validation due to inner-frame
delimiter bytes being captured as the checksum byte. The original
s3_parser.py deliberately never validates S3 checksums for exactly this
reason. We log a warning and continue.
A reply's checksum is SUM8 of its unescaped payload (748/748, measured
2026-10-26). `checksum_valid` is usually False only because S3FrameParser
sums its output with the `10` of each kept `10 02/03/04` pair still in it
-- the parser's doing, not the unit's. We log and continue.
"""
if not frame.checksum_valid:
# S3 checksums frequently fail SUM8 due to inner-frame delimiter bytes
@@ -1537,7 +1409,59 @@ class MiniMateProtocol:
f"Expected SUB=0x{expected_sub:02X}, got 0x{frame.sub:02X}"
)
def _drain_boot_string(self, drain_ms: int = 200) -> None:
# A MiniMate whose port has just opened may boot: it sends this banner a few
# seconds later and ignores a POLL sent before it. Measured on BE9441 over a
# serial cable (2026-10-25): banner ~3 s after the port opened, twice; after a
# mid-download reboot it answered 8.8 s after the banner.
_BOOT_BANNER = b"Operating System"
_BOOT_GRACE_S = 20.0
_BOOT_POLL_S = 2.0
def _await_poll_or_boot(self, timeout: float) -> Optional[S3Frame]:
"""The first POLL probe's reply -- or None the moment the unit sends its
boot banner, because a POLL sent before the banner is never answered."""
expected = _expected_rsp_sub(SUB_POLL)
self._parser.reset() # as _recv_one(reset_parser=True) did here
self._pending_frames.clear()
deadline = time.monotonic() + timeout
tail = b""
while time.monotonic() < deadline:
chunk = self._transport.read(256)
if not chunk:
time.sleep(0.005)
continue
log.debug("RX %d bytes: %s", len(chunk), chunk.hex())
frames = self._parser.feed(chunk)
if frames:
self._pending_frames.extend(frames[1:])
self._validate_frame(frames[0], expected)
return frames[0]
tail += chunk
if self._BOOT_BANNER in tail:
return None
tail = tail[-64:] # trimmed after the check, so a long read keeps it
raise TimeoutError(
f"No S3 frame received within {timeout:.1f}s (expected SUB 0x{expected:02X})")
def _poll_until_booted(self) -> S3Frame:
"""The unit said it is booting: POLL again until it answers. A read --
nothing is ever sent but SESSION_RESET and POLL."""
log.info("startup: the unit is booting (it sent %r) -- polling again until it answers",
self._BOOT_BANNER.decode())
deadline = time.monotonic() + self._BOOT_GRACE_S
while time.monotonic() < deadline:
self._send(SESSION_RESET)
self._send(POLL_PROBE)
try:
return self._recv_one(expected_sub=_expected_rsp_sub(SUB_POLL),
timeout=self._BOOT_POLL_S)
except TimeoutError:
continue
raise TimeoutError(
f"the unit sent its boot message but did not answer a POLL within "
f"{self._BOOT_GRACE_S:.0f} s")
def _drain_boot_string(self, drain_ms: int = 200) -> bool:
"""
Read and discard any boot-string bytes ("Operating System") the device
may send before entering binary protocol mode.
@@ -1545,14 +1469,21 @@ class MiniMateProtocol:
We simply read with a short timeout and throw the bytes away. The
S3FrameParser's IDLE state already handles non-frame bytes gracefully,
but it's cleaner to drain them explicitly before the first real frame.
Returns whether the boot banner was among them (the unit is booting).
"""
deadline = time.monotonic() + (drain_ms / 1000)
discarded = 0
tail, saw_banner = b"", False
while time.monotonic() < deadline:
chunk = self._transport.read(256)
if chunk:
discarded += len(chunk)
tail += chunk
saw_banner = saw_banner or self._BOOT_BANNER in tail
tail = tail[-len(self._BOOT_BANNER):] # a banner split across reads still matches
else:
time.sleep(0.005)
if discarded:
log.debug("drain_boot_string: discarded %d bytes", discarded)
return saw_banner
+146
View File
@@ -0,0 +1,146 @@
r"""Decode the Blastware sensor self-check waveforms from a series-3 event binary.
Reverse-engineered 2026-09-15 against 7 BE12844 (MiniMate Plus) oracle events.
After the main waveform record-chain and the trailing metadata / per-channel
calibration records, the binary carries four length-prefixed records tagged
0x3c-0x3f: the sensor self-check traces the unit records when it pulses each
sensor before monitoring. Blastware draws these as the little waveforms in the
"Sensor Check" strip on the right of the Event Report.
* 0x3c / 0x3d / 0x3e = Tran / Vert / Long geophone ring-downs (a damped
oscillation at the geophone's resonance, ~7-8 Hz at 1024 sps).
* 0x3f = MicL, a pulse train at the mic self-test frequency
(~20 Hz), whose zero-crossing frequency is BW's mic "Channel Test" freq.
Record framing (per record, all four chained by their length prefix)::
[len:2 BE][id:1][00 00][Nchan:1][12-byte header][delta stream][40 02][6B]
\_________________ payload (len bytes) _______________________________/
The delta stream is ``payload[20 : len-8]`` (the ``40 02`` terminator sits at
``len-8``, followed by 6 trailing bytes). It uses the exact same 10/20/30/00
delta-block tags as the main waveform codec
(:mod:`minimateplus.waveform_codec`), decoded here from an implicit anchor of 0
— so the traces come out in the same 16-count raw units as the main waveform
(LSB = 0.005 in/s at Normal range for the geophones).
"""
from __future__ import annotations
from typing import Dict, List
from minimateplus.waveform_codec import walk_body
# Record id → channel. Order mirrors the trailing per-channel calibration
# records (Tran / Vert / Long / MicL), confirmed against BW's sensor-check
# frequencies on all 7 oracle events.
_ID_TO_CHANNEL = {0x3C: "Tran", 0x3D: "Vert", 0x3E: "Long", 0x3F: "MicL"}
_CHAIN_IDS = (0x3C, 0x3D, 0x3E, 0x3F)
_HEADER_LEN = 20 # payload bytes before the delta stream
_TRAILER_LEN = 8 # 40 02 terminator + 6 trailing bytes after the stream
def _s4(nib: int) -> int:
"""Sign-extend a 4-bit nibble delta."""
return nib - 16 if nib >= 8 else nib
def _i8(byte: int) -> int:
"""Sign-extend an 8-bit int delta."""
return byte - 256 if byte >= 128 else byte
def _decode_delta_stream(buf: bytes) -> List[int]:
"""Accumulate a 10/20/30/00 delta-block stream from an anchor of 0,
stopping at the 0x40 terminator.
Mirrors the block semantics in
:func:`minimateplus.waveform_codec.decode_waveform_v2` (fully decoded &
byte-exact as of 2026-05-11); see that module for the format details.
"""
out: List[int] = []
cur = 0
for blk in walk_body(buf, 0):
fam = blk.tag_hi & 0xF0
if fam == 0x10:
# nibble deltas, high nibble first
for byte in blk.data:
for nib in ((byte >> 4) & 0xF, byte & 0xF):
cur += _s4(nib)
out.append(cur)
elif fam == 0x20:
# int8 deltas
for byte in blk.data:
cur += _i8(byte)
out.append(cur)
elif fam == 0x30:
# 12-bit signed deltas, packed as tag_lo/4 groups of 6 bytes
for g in range(blk.tag_lo // 4):
grp = blk.data[g * 6:(g + 1) * 6]
if len(grp) < 6:
break
high_word = (grp[0] << 8) | grp[1]
for k in range(4):
nib = (high_word >> (12 - 4 * k)) & 0xF
v = (nib << 8) | grp[2 + k]
if v >= 0x800:
v -= 0x1000
cur += v
out.append(cur)
elif fam == 0x00:
# RLE zero-delta run (wide form carries the high nibble in the tag)
run = ((blk.tag_hi & 0x0F) << 8) | blk.tag_lo
out.extend([cur] * run)
elif fam == 0x40:
# segment / record terminator
break
return out
def _find_chain(body: bytes):
"""Locate the four length-prefixed sensor-check records.
Returns a list of ``(offset, id, length)`` or ``None``. The chain is
validated by walking the ids 0x3c → 0x3d → 0x3e → 0x3f via their own length
prefixes, so a stray 0x3c byte in the waveform data cannot match.
"""
for p in range(len(body) - 6):
if body[p + 2] == 0x3C and body[p + 3] == 0 and body[p + 4] == 0:
q = p
recs = []
ok = True
for expect in _CHAIN_IDS:
if q + 3 > len(body) or body[q + 2] != expect:
ok = False
break
length = int.from_bytes(body[q:q + 2], "big")
recs.append((q, expect, length))
q = q + 2 + length
if ok and len(recs) == 4:
return recs
return None
def decode_sensor_check(raw: bytes) -> Dict[str, List[int]]:
"""Decode the four sensor self-check traces from a series-3 event binary.
Returns ``{"Tran": [...], "Vert": [...], "Long": [...], "MicL": [...]}`` in
raw decode units (same 16-count LSB as the main waveform), or ``{}`` if the
binary carries no sensor-check block (a histogram event, a non-series-3
file, or a unit/firmware that doesn't store it).
"""
strt = raw.find(b"STRT")
if strt < 0 or len(raw) < strt + 21 + 26:
return {}
body = raw[strt + 21: len(raw) - 26]
chain = _find_chain(body)
if not chain:
return {}
out: Dict[str, List[int]] = {}
for off, rid, length in chain:
payload = body[off + 2: off + 2 + length]
if len(payload) < _HEADER_LEN + _TRAILER_LEN:
continue
stream = payload[_HEADER_LEN: length - _TRAILER_LEN]
out[_ID_TO_CHANNEL[rid]] = _decode_delta_stream(stream)
return out
+44 -7
View File
@@ -722,7 +722,18 @@ STREAM_END_ID = 0x06
MODE_DELTA = (0x02, 0x00)
MODE_ABSOLUTE = (0x01, 0x00)
MODE_RAW12 = (0x00, 0x03)
_MODES = (MODE_DELTA, MODE_ABSOLUTE, MODE_RAW12)
# Raw int16 BE absolute samples, 10-byte header, no tags — the same shape as
# MODE_RAW12 but two bytes per sample instead of 1.5. Found on Thor/Micromate
# segment-0 records (2026-09-10): a `len=1032` record carries exactly
# (1032 - 8) / 2 = 512 samples and reproduces Thor's own export 512/512
# exactly. Before this mode existed the record fell through the dispatch
# unhandled, so the channel silently lost its first 512 samples.
MODE_RAW16 = (0x00, 0x00)
_MODES = (MODE_DELTA, MODE_ABSOLUTE, MODE_RAW12, MODE_RAW16)
# Preambles whose leading data is untagged and therefore cannot be
# block-walked; find_first_record() must scan for the next record instead.
_UNTAGGED_MODES = (MODE_RAW12, MODE_RAW16)
def _u16(b: bytes, p: int) -> int:
@@ -747,7 +758,18 @@ def data_block_len(body: bytes, p: int) -> Tuple[Optional[int], Optional[int]]:
hi = t0 & 0xF0
nn = ((t0 & 0x0F) << 8) | t1
if hi == 0x40: # int16 BE data block
return (None, None) if (nn == 0 or nn > 0x08) else (2 * nn + 2, nn)
# NN was capped at 0x08 until 2026-09-11. That cap had no basis: the
# two corpora available at the time only ever used NN in {1,2,3,4,8},
# so it was never exercised. Loud UM12947 events use NN of 12, 16,
# 20 ... up to 196, and every value above 8 halted the walk, which
# surfaced as silently short channels (walk_body/run stop at the first
# unrecognised tag rather than raising). Verified against Thor's own
# exports: 22 length-mismatched files -> 0, and the affected corpus
# went to 1,476,242/1,476,249 samples exact. The real bound is the
# buffer; the caller additionally clamps to the record end.
if nn == 0 or p + 2 * nn + 2 > len(body):
return None, None
return 2 * nn + 2, nn
if nn == 0 or nn % 4:
return None, None
if hi == 0x00:
@@ -761,6 +783,11 @@ def data_block_len(body: bytes, p: int) -> Tuple[Optional[int], Optional[int]]:
return None, None
def unpack16(data: bytes) -> List[int]:
"""Raw int16 BE absolute samples (MODE_RAW16)."""
return [_i16(data, 2 * k) for k in range(len(data) // 2)]
def unpack12(data: bytes) -> List[int]:
"""Raw 12-bit packed samples: 6 bytes -> 4 signed values."""
out: List[int] = []
@@ -785,13 +812,17 @@ def find_first_record(body: bytes) -> Optional[int]:
"""Offset of the first record, or None.
Under the normal ``00 02 00`` preamble the leading bytes are segment-0's
Tran blocks, so walk them. Under the ``00 00 03`` preamble that data is
raw 12-bit with no tags at all and cannot be block-walked — scan instead.
Tran blocks, so walk them. Under the untagged preambles (``00 00 03``
raw-12 and ``00 00 00`` raw-16) that data has no tags at all and cannot
be block-walked — scan for the next record header instead.
"""
if len(body) >= 3 and (body[1], body[2]) == MODE_RAW12:
if len(body) >= 3 and (body[1], body[2]) in _UNTAGGED_MODES:
scan_from = 3
else:
i = 7
# Tagged preamble. MODE_DELTA carries a 14-byte record header (two
# int16 anchors), so its blocks start at body[7]; MODE_ABSOLUTE has a
# 10-byte header and starts at body[3].
i = 3 if (len(body) >= 3 and (body[1], body[2]) == MODE_ABSOLUTE) else 7
while i < len(body):
if is_record(body, i):
nxt = i + 2 + _u16(body, i + 2)
@@ -850,7 +881,7 @@ def decode_waveform_v2(body: bytes) -> Optional[dict]:
if len(body) < 8 or body[0] != 0x00:
return None
preamble = (body[1], body[2])
if preamble not in (MODE_DELTA, MODE_RAW12):
if preamble not in (MODE_DELTA, MODE_ABSOLUTE, MODE_RAW12, MODE_RAW16):
return None
first = find_first_record(body)
if first is None:
@@ -895,6 +926,10 @@ def decode_waveform_v2(body: bytes) -> Optional[dict]:
if preamble == MODE_DELTA:
out["Tran"].extend([_i16(body, 3), _i16(body, 5)])
run("Tran", 7, first, absolute=False)
elif preamble == MODE_ABSOLUTE:
run("Tran", 3, first, absolute=True)
elif preamble == MODE_RAW16:
out["Tran"].extend(unpack16(body[3:first]))
else:
out["Tran"].extend(unpack12(body[3:first]))
@@ -908,4 +943,6 @@ def decode_waveform_v2(body: bytes) -> Optional[dict]:
run(ch, off + 10, end, absolute=True)
elif mode == MODE_RAW12:
out[ch].extend(unpack12(body[off + 10:end]))
elif mode == MODE_RAW16:
out[ch].extend(unpack16(body[off + 10:end]))
return out
+1 -1
View File
@@ -4,7 +4,7 @@ build-backend = "setuptools.build_meta"
[project]
name = "seismo-relay"
version = "0.29.0"
version = "0.31.0"
description = "Python client and REST server for MiniMate Plus seismographs"
requires-python = ">=3.10"
dependencies = [
+33
View File
@@ -0,0 +1,33 @@
"""Pretend to be a Micromate on a serial port: log what arrives, reply to POLL.
Proves the modem's return path (serial -> TCP) independently of the real unit.
"""
import os, select, sys, termios, time
path, baud = sys.argv[1], int(sys.argv[2]) if len(sys.argv) > 2 else 115200
B = {9600: termios.B9600, 38400: termios.B38400, 115200: termios.B115200}[baud]
fd = os.open(path, os.O_RDWR | os.O_NOCTTY | os.O_NONBLOCK)
a = termios.tcgetattr(fd)
a[0] = a[1] = a[3] = 0
a[2] = termios.CS8 | termios.CREAD | termios.CLOCAL
a[4] = a[5] = B
a[6] = list(a[6]); a[6][termios.VMIN] = 0; a[6][termios.VTIME] = 0
termios.tcsetattr(fd, termios.TCSANOW, a)
termios.tcflush(fd, termios.TCIOFLUSH)
# A real POLL probe reply, captured from UM12947 on 2026-09-24.
REPLY = bytes.fromhex("0200c5a4000000000000300000000000000099") + b"\x03"
print(f"fake unit on {path} @ {baud}; will answer any inbound frame", flush=True)
while True:
r, _, _ = select.select([fd], [], [], 1.0)
if not r:
continue
data = os.read(fd, 4096)
if not data:
continue
ts = time.strftime("%H:%M:%S")
print(f"{ts} IN {len(data):3} B {data.hex(' ')}", flush=True)
time.sleep(0.02)
os.write(fd, REPLY)
print(f"{ts} OUT {len(REPLY):3} B {REPLY.hex(' ')} <- canned POLL reply", flush=True)
+368
View File
@@ -0,0 +1,368 @@
#!/usr/bin/env python3
"""mm_config_diff.py — snapshot a Micromate's config blocks and diff them.
**Read-only.** Sends only the five config reads plus POLL/SERIAL. It never
writes, never erases, never starts or stops monitoring.
Why it exists
-------------
`docs/micromate_protocol_reference.md` has about a dozen fields read out of
`SUB 0x1A` (2,103 bytes) and *nothing* out of `0x2C`, `0x2E`, `0x08` or `0x01`.
They are fetched and undecoded. The method that mapped the Series III config
was a diff loop: change exactly one setting, re-read, see which bytes moved.
This is that loop for Series IV.
The one thing that loop needs first
-----------------------------------
**Which bytes move on their own.** A config block read twice, thirty seconds
apart, with nothing touched, is not byte-identical — it carries a clock, a free
-memory figure and at least one counter. Diff two snapshots taken either side
of a setting change and those bytes show up alongside the real answer, and
there is no way to tell which is which from a single pair.
So `volatile` runs first: N reads back to back, nothing changed, and every byte
that differs is recorded as noise. `diff` then reports the two sets
separately. Without that baseline a diff is suggestive; with it, it is
evidence.
Usage
-----
# establish the noise floor FIRST -- nothing touched between reads
python3 scratch/mm_config_diff.py /dev/ttyACM0 volatile -n 4
# baseline, then change ONE setting on the unit's keypad, then:
python3 scratch/mm_config_diff.py /dev/ttyACM0 snap before
python3 scratch/mm_config_diff.py /dev/ttyACM0 snap after-rectime-4s
python3 scratch/mm_config_diff.py /dev/ttyACM0 diff before after-rectime-4s
Snapshots live in `scratch/mm_config_snaps/<serial>/<label>/`, which is
gitignored like the other capture artefacts.
"""
from __future__ import annotations
import argparse
import json
import struct
import sys
import time
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
from bridges.mm_client_check import StdlibSerial # noqa: E402
from micromate.client import MicromateClient # noqa: E402
from micromate.setup_block import crc_ok # noqa: E402
from minimateplus.transport import TcpTransport # noqa: E402
SNAP_ROOT = Path(__file__).resolve().parent / "mm_config_snaps"
# Content starts at data[11]; the reference documents fields as content[N], so
# every changed offset is reported both ways to save a subtraction per finding.
CONTENT = 11
# Block name -> the protocol method that reads it. 0x1C is included on purpose:
# it is the one block whose volatility is already known (it carries the clock),
# so it doubles as a positive control that the volatile pass is working.
# Bytes that are KNOWN volatile from the field layout, seeded regardless of
# whether they happened to move during the sample window. An empirical noise
# floor only catches what moves WHILE sampling: a four-read pass over eight
# seconds sees the sub-second tick and the seconds byte and silently misses
# minutes, hours and the date, which then surface later as fake "findings".
# 0x1C content[2:10] is day/month/year/tick/hour/min/sec; content starts at 11.
# Memory-free (content[40:44]) is deliberately NOT masked -- it moves only when
# the unit actually records, which is a thing worth being told about.
KNOWN_VOLATILE = {
"1C_monitor_status": list(range(11 + 2, 11 + 10)),
}
BLOCKS = {
"1A_compliance": "read_compliance_config",
"2C_call_home": "read_call_home_config",
"2E_trigger": "read_trigger_config",
"08_event_index": "read_event_index",
"01_device_info": "read_device_info",
"1C_monitor_status": "read_monitor_status",
}
def _open(target: str, timeout: float):
if ":" in target and not target.startswith("/"):
host, _, port = target.rpartition(":")
return TcpTransport(host, int(port))
return StdlibSerial(target, baud=115200)
def read_all(mm: MicromateClient) -> dict[str, bytes]:
out = {}
for name, meth in BLOCKS.items():
try:
out[name] = bytes(getattr(mm._proto, meth)())
except Exception as e: # noqa: BLE001
print(f" {name}: FAILED {type(e).__name__}: {e}")
return out
def save(serial: str, label: str, blocks: dict[str, bytes]) -> Path:
d = SNAP_ROOT / serial / label
d.mkdir(parents=True, exist_ok=True)
for name, raw in blocks.items():
(d / f"{name}.bin").write_bytes(raw)
(d / "meta.json").write_text(json.dumps({
"serial": serial,
"label": label,
"taken": time.strftime("%Y-%m-%dT%H:%M:%S"),
"sizes": {k: len(v) for k, v in blocks.items()},
}, indent=2))
return d
def load(serial: str, label: str) -> dict[str, bytes]:
d = SNAP_ROOT / serial / label
if not d.is_dir():
sys.exit(f"no snapshot '{label}' for {serial} (looked in {d})")
return {p.stem: p.read_bytes() for p in sorted(d.glob("*.bin"))}
def _interps(a: bytes, b: bytes, off: int, run: int) -> list[str]:
"""How a changed run reads under each plausible field type."""
out = [f"u8 {a[off]:3d} -> {b[off]:3d}"]
if run <= 2 and off + 2 <= len(a):
x, y = struct.unpack_from(">H", a, off)[0], struct.unpack_from(">H", b, off)[0]
out.append(f"u16be {x} -> {y}")
if run <= 4 and off + 4 <= len(a):
x, y = struct.unpack_from(">I", a, off)[0], struct.unpack_from(">I", b, off)[0]
out.append(f"u32be {x} -> {y}")
fx, fy = struct.unpack_from(">f", a, off)[0], struct.unpack_from(">f", b, off)[0]
if all(abs(v) < 1e9 and (v == 0 or abs(v) > 1e-6) for v in (fx, fy)):
out.append(f"f32be {fx:g} -> {fy:g}")
return out
# Blocks that carry the config checksum (micromate.setup_block.crc_ok): N =
# content[0:2], CRC-16/AUG-CCITT over [0:N-2] stored at [N:N+2]. 0x2C has none.
CRC_BLOCKS = {"1A_compliance", "08_event_index", "2E_trigger"}
def crc_status(raw: bytes) -> str:
"""A mismatch means a short or corrupt read -- or a block this rule misses."""
c = raw[CONTENT:]
stored = c[int.from_bytes(c[0:2], "big"):][:2].hex() if len(c) >= 2 else "--"
return f"CRC ok ({stored})" if crc_ok(c) else f"CRC MISMATCH (stored {stored})"
def _runs(a: bytes, b: bytes, ignore: set[int]) -> list[tuple[int, int]]:
"""Contiguous runs of differing offsets, skipping known-volatile ones."""
diff = [i for i in range(min(len(a), len(b)))
if a[i] != b[i] and i not in ignore]
runs, start = [], None
for i, off in enumerate(diff):
if start is None:
start = off
if i + 1 == len(diff) or diff[i + 1] != off + 1:
runs.append((start, off - start + 1))
start = None
return runs
def cmd_volatile(mm: MicromateClient, serial: str, n: int) -> None:
print(f"\n{n} reads back to back, nothing touched between them.")
print("Every byte that moves here is noise and must be excluded from a diff.\n")
snaps = []
for i in range(n):
print(f" read {i + 1}/{n} ...", end="", flush=True)
snaps.append(read_all(mm))
print(" ok")
if i + 1 < n:
time.sleep(2.0)
volatile: dict[str, list[int]] = {}
for name in snaps[0]:
moved = set()
for later in snaps[1:]:
if name not in later:
continue
a, b = snaps[0][name], later[name]
if len(a) != len(b):
print(f" {name}: LENGTH CHANGED {len(a)} -> {len(b)} -- that is itself a finding")
moved |= {i for i in range(min(len(a), len(b))) if a[i] != b[i]}
volatile[name] = sorted(moved | set(KNOWN_VOLATILE.get(name, [])))
print()
for name, offs in volatile.items():
size = len(snaps[0][name])
seeded = set(KNOWN_VOLATILE.get(name, []))
observed = set(offs) - seeded
if not offs:
print(f" {name:20s} {size:5d} B STABLE -- every byte held still")
else:
note = f"{len(observed)} observed"
if seeded:
note += f" + {len(seeded)} seeded from the known clock layout"
print(f" {name:20s} {size:5d} B {len(offs):4d} volatile ({note})")
print(f" {'':20s} {offs[:20]}" + (" ..." if len(offs) > 20 else ""))
out = SNAP_ROOT / serial / "volatile.json"
out.parent.mkdir(parents=True, exist_ok=True)
out.write_text(json.dumps(volatile, indent=2))
print(f"\nwrote {out}")
print("`diff` reads this automatically and reports noise separately.")
def cmd_diff(serial: str, a_label: str, b_label: str) -> None:
A, B = load(serial, a_label), load(serial, b_label)
vpath = SNAP_ROOT / serial / "volatile.json"
vol = json.loads(vpath.read_text()) if vpath.is_file() else {}
if not vol:
print("⚠ no volatile.json -- run `volatile` first, or every clock tick")
print(" below will look like a config field.\n")
for name in sorted(set(A) & set(B)):
a, b = A[name], B[name]
ignore = set(vol.get(name, []))
if len(a) != len(b):
print(f"\n{name}: LENGTH {len(a)} -> {len(b)} (a length change is a finding)")
runs = _runs(a, b, ignore)
noise = sum(1 for i in range(min(len(a), len(b)))
if a[i] != b[i] and i in ignore)
if not runs:
tail = f" ({noise} volatile bytes ignored)" if noise else ""
print(f"\n{name:20s} no non-volatile change{tail}")
continue
print(f"\n{name} — {len(runs)} changed run(s)"
+ (f", {noise} volatile bytes ignored" if noise else ""))
for off, run in runs:
print(f" @{off:5d} (0x{off:04x}) content[{off - CONTENT:d}] {run} B "
f"{a[off:off + run].hex()} -> {b[off:off + run].hex()}")
for line in _interps(a, b, off, run):
print(f" {line}")
def cmd_watch(mm: MicromateClient, serial: str, interval: float,
duration: float, prefix: str | None = None) -> None:
"""Poll the config blocks and report each change as it lands.
A round trip per setting means walking to the unit and back for every
field. This instead lets one person stand at the keypad changing settings
one at a time while every change is timestamped here, so a whole session is
one pass. Each distinct state is also saved as `<prefix>-NNN`, so the
sequence can be re-diffed offline afterwards without the unit.
The prefix defaults to `watch-MMDD-HHMM`, i.e. one per session. It used to
be a fixed `watch-`, so every run silently overwrote the previous run's
snapshots -- harmless while they were clock ticks, data loss once they
were findings.
"""
prefix = prefix or time.strftime("watch-%m%d-%H%M")
vpath = SNAP_ROOT / serial / "volatile.json"
vol = json.loads(vpath.read_text()) if vpath.is_file() else {}
if not vol:
print("⚠ no volatile.json -- run `volatile` first.\n")
print(f"watching every {interval:g}s"
+ (f" for {duration:g}s" if duration else " until Ctrl-C"))
print("change ONE setting at a time on the unit's keypad; each change is")
print(f"timestamped below and saved as {prefix}-NNN.\n")
prev = read_all(mm)
save(serial, f"{prefix}-000", prev)
print(f"[{time.strftime('%H:%M:%S')}] baseline captured ({prefix}-000)")
for k, v in sorted(prev.items()):
print(f" {k:20s} {len(v):5d} B")
print()
n, t0 = 0, time.monotonic()
try:
while not duration or time.monotonic() - t0 < duration:
time.sleep(interval)
cur = read_all(mm)
hits = []
for name in sorted(set(prev) & set(cur)):
a, b = prev[name], cur[name]
ignore = set(vol.get(name, []))
if len(a) != len(b):
hits.append((name, None, len(a), len(b)))
continue
runs = _runs(a, b, ignore)
if runs:
hits.append((name, runs, None, None))
if not hits:
continue
n += 1
label = f"{prefix}-{n:03d}"
save(serial, label, cur)
print(f"[{time.strftime('%H:%M:%S')}] CHANGE #{n} ({label})")
for name, runs, la, lb in hits:
if runs is None:
print(f" {name}: LENGTH {la} -> {lb} (a length change is a finding)")
continue
print(f" {name} — {len(runs)} run(s)")
for off, run in runs:
a, b = prev[name], cur[name]
print(f" @{off:5d} (0x{off:04x}) content[{off - CONTENT:d}] {run} B "
f"{a[off:off + run].hex()} -> {b[off:off + run].hex()}")
for line in _interps(a, b, off, run):
print(f" {line}")
if name in CRC_BLOCKS:
print(f" {crc_status(cur[name])}")
print(flush=True)
prev = cur
except KeyboardInterrupt:
print("\nstopped.")
print(f"{n} change(s) recorded; snapshots {prefix}-000..{prefix}-{n:03d} under")
print(f" {SNAP_ROOT / serial}")
def main() -> int:
p = argparse.ArgumentParser(description=__doc__,
formatter_class=argparse.RawDescriptionHelpFormatter)
p.add_argument("target", help="/dev/ttyACM0 or host:port")
p.add_argument("--timeout", type=float, default=10.0)
sub = p.add_subparsers(dest="cmd", required=True)
s = sub.add_parser("snap", help="read all blocks and save under a label")
s.add_argument("label")
v = sub.add_parser("volatile", help="find bytes that move with nothing changed")
v.add_argument("-n", type=int, default=4)
w = sub.add_parser("watch", help="poll and report each change as it lands")
w.add_argument("--interval", type=float, default=2.0)
w.add_argument("--duration", type=float, default=0.0, help="0 = until Ctrl-C")
w.add_argument("--prefix", help="snapshot label prefix (default: watch-MMDD-HHMM)")
d = sub.add_parser("diff", help="diff two saved snapshots")
d.add_argument("a")
d.add_argument("b")
d.add_argument("--serial", help="override (default: read from the unit)")
a = p.parse_args()
# `diff` is pure offline work on saved files -- do not touch the unit for it.
if a.cmd == "diff" and a.serial:
cmd_diff(a.serial, a.a, a.b)
return 0
transport = _open(a.target, a.timeout)
mm = MicromateClient(transport, recv_timeout=a.timeout)
mm.open() # opens the port; connect() only handshakes
info = mm.connect()
serial = info.serial or "unknown"
print(f"{serial} {info.model} fw={info.firmware_line} "
f"setup={info.active_setup} monitoring={info.monitoring}")
try:
if a.cmd == "snap":
blocks = read_all(mm)
d = save(serial, a.label, blocks)
print(f"\nsaved {len(blocks)} blocks -> {d}")
for k, v2 in sorted(blocks.items()):
print(f" {k:20s} {len(v2):5d} B")
elif a.cmd == "volatile":
cmd_volatile(mm, serial, a.n)
elif a.cmd == "watch":
cmd_watch(mm, serial, a.interval, a.duration, a.prefix)
elif a.cmd == "diff":
cmd_diff(serial, a.a, a.b)
finally:
mm.close()
return 0
if __name__ == "__main__":
raise SystemExit(main())
+223
View File
@@ -0,0 +1,223 @@
#!/usr/bin/env python3
"""
mm_frame_parse.py — parse Micromate (Series IV) frames out of a seismo_lab
raw capture pair.
Why this exists
---------------
`minimateplus.framing.S3FrameParser` cannot see Micromate traffic. It locates
frames by scanning for `DLE STX`, and a Micromate response has **no leading
DLE** — it starts at a bare `STX`. It also expects `payload[1] == 0x10`, where
the Micromate sends `0xC5` (Blastware firmware) or `0x03` (Thor firmware).
The practical consequence, seen on the 9-24-26 setup-push capture: the
Blastware-side requests parse fine (Thor emits Series III request frames), but
**every device response is silently dropped or mis-framed** — so a capture that
actually contains 12 acked writes looks like 12 unanswered requests.
Destuffing
----------
One rule covers both directions: after the leading doubled `BW_CMD`, every
`10 XX` pair on the wire destuffs to `XX`. That includes `10 03` — Thor
escapes literal `0x03` bytes in write data so they are not mistaken for ETX,
exactly as Blastware does.
A Micromate escapes exactly four byte values — `0x02 0x03 0x04 0x10` — and
nothing else, which is what makes the uniform rule exact rather than merely
convenient. Established by re-stuffing all 502 captured frames and comparing
to the wire: 251/251 each direction, where `{0x10}` alone gets 130 and 177.
⚠ Checksum, corrected 2026-09-27
--------------------------------
With uniform destuffing the checksum is **plain SUM8 of the destuffed
payload**. This script used to try SUM8 *and* a "DLE-aware" variant that
excludes `0x10` bytes, and report whichever matched — which is why it never
flagged a bad frame and why the protocol reference carried the wrong rule for
two days. The DLE-aware form belongs with *Series III* destuffing, where an
escaped byte survives as two bytes; applying it after uniform destuffing
subtracts the correction twice and disagrees with the wire on 55 of 251
responses.
The lesson generalises: a tool that accepts any of N candidate rules cannot
falsify any of them. It now validates against SUM8 alone, and reports
`DLE-aware` only to name what a mismatch *would* have been — never as a pass.
See `docs/micromate_protocol_reference.md` → *Checksum*, and
`tests/test_micromate_framing.py`, which pins it.
`micromate/framing.py` is the production implementation; this stays as the
one-shot capture-inspection tool.
Usage
-----
python scratch/mm_frame_parse.py <capture-dir>
python scratch/mm_frame_parse.py <raw_bw.bin> <raw_s3.bin>
python scratch/mm_frame_parse.py <capture-dir> --dump 0x71
"""
from __future__ import annotations
import argparse
import sys
from pathlib import Path
DLE, STX, ETX, ACK = 0x10, 0x02, 0x03, 0x41
# Request SUB -> short name. Series III names where they carry over; the
# Series IV additions are marked.
SUBNAME = {
0x01: "DEVICE_INFO",
0x06: "STORAGE_RANGE",
0x08: "EVENT_INDEX",
0x0A: "WAVEFORM_HDR",
0x0C: "WAVEFORM_REC",
0x15: "SERIAL",
0x1A: "COMPLIANCE_CFG",
0x1C: "MONITOR_STATUS",
0x1E: "EVENT_HDR",
0x2C: "CALLHOME_CFG",
0x2E: "TRIGGER_CFG_READ", # Series IV
0x3E: "OPERATOR",
0x41: "SETUP_NAME_READ", # Series IV
0x5A: "BULK_DOWNLOAD",
0x5B: "POLL",
0x68: "EVENT_INDEX_WRITE",
0x69: "WAVEFORM_WRITE",
0x71: "COMPLIANCE_WRITE",
0x72: "CONFIRM_A",
0x73: "CONFIRM_B",
0x74: "CONFIRM_C",
0x82: "TRIGGER_WRITE",
0x83: "TRIGGER_CONFIRM",
0xDA: "SETUP_FILE_DECL", # Series IV — names the target .MMB
0xFE: "FULL_CFG",
}
def destuff(blob: bytes, start: int, *, is_request: bool) -> tuple[bytes, int, int]:
"""Destuff one frame starting at `start`.
Returns (payload, checksum, index_of_terminating_ETX). `payload` excludes
the trailing checksum byte. A request frame opens `ACK STX 10 10`; a
response opens with a bare `STX`.
"""
i = start + (2 if is_request else 1)
out = bytearray()
if is_request:
# The doubled BW_CMD is the one guaranteed stuffed byte.
if blob[i : i + 2] != bytes([DLE, DLE]):
raise ValueError(f"@0x{start:04x}: request does not open with 10 10")
out.append(DLE)
i += 2
while i < len(blob):
b = blob[i]
if b == DLE and i + 1 < len(blob):
out.append(blob[i + 1])
i += 2
continue
if b == ETX:
break
out.append(b)
i += 1
if len(out) < 2:
raise ValueError(f"@0x{start:04x}: frame too short")
return bytes(out[:-1]), out[-1], i
def frames(blob: bytes, *, is_request: bool):
"""Yield (offset, payload, chk, checksum_kind)."""
i, n = 0, len(blob)
while i < n:
if is_request:
if not (blob[i] == ACK and i + 1 < n and blob[i + 1] == STX):
i += 1
continue
elif blob[i] != STX:
i += 1
continue
try:
payload, chk, end = destuff(blob, i, is_request=is_request)
except ValueError:
i += 1
continue
# SUM8 of the destuffed payload is THE rule -- 502/502 captured frames.
# The DLE-aware variant is reported only to name a near-miss; it is
# never a pass. See the module docstring.
if (sum(payload) & 0xFF) == chk:
kind = "ok"
elif (sum(b for b in payload if b != DLE) & 0xFF) == chk:
kind = "BAD(dle-aware)"
else:
kind = "BAD"
yield i, payload, chk, kind
i = end + 1
def describe(payload: bytes, is_request: bool) -> str:
if len(payload) < 3:
return "??"
sub = payload[2]
if is_request:
return SUBNAME.get(sub, f"SUB_{sub:02X}")
req = 0xFF - sub
return "rsp<-" + SUBNAME.get(req, f"SUB_{req:02X}")
def report(path: Path, *, is_request: bool, dump_sub: int | None) -> None:
blob = path.read_bytes()
side = "Thor" if is_request else "unit"
print(f"== {side:4} {path.name} ({len(blob)} bytes)")
n_bad = 0
for idx, (off, p, chk, kind) in enumerate(frames(blob, is_request=is_request)):
if kind == "BAD":
n_bad += 1
sub = p[2] if len(p) > 2 else -1
flags = p[1] if len(p) > 1 else -1
# Requests carry offset at payload[4:6]; responses page at [3:5].
word = int.from_bytes(p[4:6] if is_request else p[3:5], "big")
data = len(p) - 16 if is_request else max(len(p) - 5, 0)
print(
f" [{idx:2}] @0x{off:04x} payload={len(p):5} data={data:5} "
f"flags=0x{flags:02x} SUB=0x{sub:02x} {describe(p, is_request):18} "
f"{'offset' if is_request else 'page'}=0x{word:04x} chk={kind}"
)
if dump_sub is not None and sub == dump_sub:
body = p[16:] if is_request else p[5:]
print(f" ---- data ({len(body)} bytes) ----")
for o in range(0, len(body), 16):
chunk = body[o : o + 16]
txt = "".join(chr(c) if 32 <= c < 127 else "." for c in chunk)
print(f" {o:06x} {chunk.hex(' '):<47} |{txt}|")
print(f" -- {idx + 1} frames, {n_bad} bad checksum\n")
def main() -> int:
ap = argparse.ArgumentParser(description=__doc__,
formatter_class=argparse.RawDescriptionHelpFormatter)
ap.add_argument("paths", nargs="+",
help="a capture directory, or raw_bw.bin and raw_s3.bin")
ap.add_argument("--dump", default=None,
help="hex-dump the data section of this SUB (e.g. 0x71)")
args = ap.parse_args()
dump_sub = int(args.dump, 0) if args.dump else None
if len(args.paths) == 1 and Path(args.paths[0]).is_dir():
d = Path(args.paths[0])
bw = sorted(d.glob("raw_bw_*.bin"))
s3 = sorted(d.glob("raw_s3_*.bin"))
if not bw or not s3:
print(f"{d}: need one raw_bw_*.bin and one raw_s3_*.bin", file=sys.stderr)
return 2
pairs = [(bw[0], True), (s3[0], False)]
elif len(args.paths) == 2:
pairs = [(Path(args.paths[0]), True), (Path(args.paths[1]), False)]
else:
ap.error("pass a capture directory, or exactly two .bin files")
for path, is_request in pairs:
report(path, is_request=is_request, dump_sub=dump_sub)
return 0
if __name__ == "__main__":
sys.exit(main())
+228
View File
@@ -0,0 +1,228 @@
#!/usr/bin/env python3
"""
mm_stream_probe.py — how many bytes will `SUB 0x5A` serve in one request?
Settled 2026-10-02: there is NO streaming mode
----------------------------------------------
This script started out asking whether `offset_hi = 0x10` meant "stream until
done", because our 2026-09-23 notes recorded a single request appearing to return
an entire 11 KB event. Measured directly on UM20147, it does not:
offset 0x1014 (4116) -> one frame, 4127 B data, 4116 B of file
offset 0x111c (4380) -> one frame, 4391 B data, 4380 B of file
**`offset` is simply a byte count**, and the device returns exactly `offset + 11`
bytes in one frame. `0x1000` is not a marker; it is part of the number. The
2026-09-23 reading was wrong, and the protocol reference now says so.
The useful question it turned up
-------------------------------
**1024 bytes per request is THOR's choice, not the device's limit.** The unit
served 4,380 bytes in a single frame without being asked twice. Since a round
trip over cellular costs ~0.65 s regardless of payload, and UM20147's
72,560-byte event is 71 chunks ≈ 46 seconds, the ceiling on one request is worth
knowing precisely: every doubling halves the dominant cost.
So this now walks ascending request sizes against one event and **checks each
against a known-good chunk-loop download** — a pass means byte-identical output,
not merely a plausible length. The offset field is a uint16, so 65,535 is the
structural maximum.
⚠ **Read-only.** `0x5A` is a read we have sent thousands of times; the only new
thing is a larger value in its offset field. Nothing here writes, erases or
changes monitoring state. It re-POLLs at the end, because the honest risk is
leaving the session in an odd state and the script should say so.
Usage
-----
python3 scratch/mm_stream_probe.py /dev/ttyACM1
python3 scratch/mm_stream_probe.py /dev/ttyACM1 --event largest
"""
from __future__ import annotations
import argparse
import math
import sys
import time
from pathlib import Path
sys.path.insert(0, str(Path(__file__).resolve().parent.parent))
sys.path.insert(0, str(Path(__file__).resolve().parent.parent / "bridges"))
from micromate.client import MicromateClient, _content # noqa: E402
from micromate.framing import MicromateFrameParser, build_request # noqa: E402
from micromate.protocol import SUB_BULK_DOWNLOAD, THOR_CHUNK_SIZE # noqa: E402
from mm_client_check import StdlibSerial # noqa: E402
from minimateplus.transport import TcpTransport # noqa: E402
_CHUNK_PREFIX = 11
def collect(transport, parser, *, idle_gap: float, deadline: float) -> list:
"""Read until `idle_gap` seconds pass with no new bytes, or `deadline`."""
frames, last = [], time.monotonic()
while time.monotonic() < deadline:
chunk = transport.read(4096)
if chunk:
frames += parser.feed(chunk)
last = time.monotonic()
continue
if time.monotonic() - last > idle_gap:
break
time.sleep(0.005)
return frames
def main() -> int:
ap = argparse.ArgumentParser(
description=__doc__, formatter_class=argparse.RawDescriptionHelpFormatter
)
ap.add_argument("target", help="host:port, or a serial device path")
ap.add_argument("--baud", type=int, default=115200)
ap.add_argument("--event", default="smallest",
help="a key in hex, 'smallest' (default — the gentlest "
"first test) or 'largest' (the one that matters)")
ap.add_argument("--idle-gap", type=float, default=3.0,
help="seconds of silence that end a read. A 16 KB response "
"is ~1.4 s of serial time at 115200 BEFORE the modem's "
"~1 s forwarding delay, so this is deliberately roomy; "
"too small and a slow link looks like a clamp.")
ap.add_argument("--timeout", type=float, default=90.0)
a = ap.parse_args()
if ":" in a.target and not Path(a.target).exists():
host, _, port = a.target.rpartition(":")
inner = TcpTransport(host, int(port), connect_timeout=10.0)
label = f"TCP {host}:{port}"
else:
inner = StdlibSerial(a.target, baud=a.baud)
label = f"serial {a.target} @ {a.baud}"
mm = MicromateClient(inner, recv_timeout=20.0)
print(f"\n{label} READ-ONLY: chain walk + two downloads of one event\n")
mm.open()
try:
info = mm.connect(with_active_setup=False)
print(f" {info}\n")
refs = mm.list_events()
if not refs:
print(" no events stored — nothing to download. Record one first.")
return 1
for r in refs:
print(f" {r}")
which = a.event.strip().lower()
if which == "smallest":
ref = min(refs, key=lambda r: r.size)
elif which == "largest":
ref = max(refs, key=lambda r: r.size)
else:
matches = [r for r in refs if r.key_hex.lower() == which]
if not matches:
print(f"\n --event {a.event!r} matched nothing")
return 2
ref = matches[0]
n_chunks = math.ceil(ref.size / THOR_CHUNK_SIZE)
print(f"\n target: {ref.key_hex} {ref.size} B {ref.record_type} "
f"({n_chunks} requests at THOR's chunk size)")
# ── 1. the control: THOR's 1024-byte chunk loop ───────────────────────
# ⚠ Pinned to THOR_CHUNK_SIZE on purpose. The library default is now
# 16,384, and using it here would make the experiment circular -- the
# "known-good" reference would share any fault with the sizes under test.
# 1024 is the size with THOR's own captures behind it and the one proven
# over a modem, so it is the control.
t0 = time.monotonic()
chunked = mm.protocol.read_event_file(ref.key, ref.size,
chunk_size=THOR_CHUNK_SIZE)
dt_chunked = time.monotonic() - t0
print(f"\n [1] control ......... {len(chunked)} B in {dt_chunked:.2f} s "
f"({n_chunks} requests at THOR's 1024 B)")
# ── 2. how many bytes will it serve in ONE frame? ─────────────────
# The streaming hypothesis is dead (see the module docstring): `offset`
# is simply a BYTE COUNT, and the device returns `offset + 11` bytes in
# one frame. So the real question is the ceiling -- because 1024 is
# THOR's choice, not the device's limit, and every doubling halves the
# round trips that dominate a cellular download.
print("\n [2] chunk-size ceiling — ascending single requests")
print(" each asks for N bytes from offset 0 and is checked against")
print(" the known-good download, so a pass means identical bytes.\n")
candidates = [1024, 2048, 4096, 8192, 16384, 32768, 65535]
candidates = [n for n in candidates if n <= ref.size] or [ref.size]
if ref.size not in candidates and ref.size < 65536:
candidates.append(ref.size) # the whole event in one request
best = None
for n in candidates:
frame = build_request(SUB_BULK_DOWNLOAD, n, ref.key + bytes(6))
parser = MicromateFrameParser()
t0 = time.monotonic()
mm.protocol._send(frame)
got = collect(inner, parser, idle_gap=a.idle_gap,
deadline=t0 + a.timeout)
dt = time.monotonic() - t0
if not got:
print(f" {n:6} B no answer ({dt:.2f} s)")
continue
body = b"".join(f.data[_CHUNK_PREFIX:] for f in got)
ok = body == chunked[:n]
flag = "OK " if ok else "MISMATCH"
# ⚠ dt includes the idle gap: collect() waits `idle_gap` after the
# last byte before deciding the response is over. Subtract it to
# compare against the control, which reads to frame completion.
print(f" {n:6} B {len(got)} frame(s) {len(body):6} B back "
f"{dt:5.2f} s ({max(dt - a.idle_gap, 0):4.2f} s net) {flag}"
+ ("" if ok or not body else
f" (first diff at {next((i for i in range(min(len(body), n)) if body[i] != chunked[i]), None)})"))
if ok and len(body) == n:
best = n
print()
if best is None:
print(" VERDICT: nothing above the current chunk size verified.")
else:
now = math.ceil(ref.size / THOR_CHUNK_SIZE)
then = math.ceil(ref.size / best)
print(f" VERDICT: the device serves at least {best} B per request,")
print(f" verified byte-identical. For this {ref.size} B event that")
print(f" is {then} request(s) instead of {now}.")
if best > THOR_CHUNK_SIZE:
# ⚠ cost is ~0.21 s per request PLUS ~2,350 B/s over a modem --
# a download is throughput-bound, so do not promise a saving
# proportional to the drop in request count.
fixed, rate = 0.212, 2348.0
t_now = now * fixed + ref.size / rate
t_then = then * fixed + ref.size / rate
print(f" Modelled over cellular (0.21 s/request + "
f"{rate:.0f} B/s): {t_now:.1f} s -> {t_then:.1f} s, "
f"a {100 * (1 - t_then / t_now):.0f}% saving.")
print(" Throughput-bound, not round-trip bound — most of that is")
print(" bytes on the wire and batching does not touch it.")
if best >= ref.size:
print(" The WHOLE EVENT fits in one request.")
# ── 3. is the unit still healthy? ─────────────────────────────────────
# The real risk of this experiment is leaving the session wedged, so
# check rather than assume.
print()
try:
p = mm.protocol.poll()
print(f" [3] unit still answering POLL (SUB 0x{p.sub:02x}) — "
f"session is healthy")
except Exception as e:
print(f" [3] ⚠ POLL FAILED after the probe: {type(e).__name__}: {e}")
print(" Reconnect; if that does not help, power-cycle the unit.")
return 4
finally:
mm.close()
return 0
if __name__ == "__main__":
raise SystemExit(main())
+98
View File
@@ -0,0 +1,98 @@
#!/usr/bin/env python3
"""Cut Micromate write-session fixtures out of THOR's captures.
bridges/captures/ is gitignored, so the reproduction tests read these instead.
Each fixture is every request (as wire bytes) and every response (as its data
section) of one captured THOR session, paired in order, with the sha256 of the
capture files it came from. Re-run to regenerate:
.venv/bin/python scratch/mm_write_fixtures.py
"""
from __future__ import annotations
import hashlib
import json
import sys
from pathlib import Path
REPO = Path(__file__).resolve().parent.parent
sys.path.insert(0, str(REPO))
from micromate.framing import ACK, DLE, ETX, STX, MicromateFrameParser, request_sub # noqa: E402
CAP = REPO / "bridges" / "captures" / "9-24-26 - micromate2"
OUT = REPO / "tests" / "fixtures" / "micromate-writes"
SESSIONS = {
"setup-push-new-test1": "20260924_181942_send_TEST1_to_unit",
"setup-push-overwrite-test1": "overwritetest/*20260924_185113_test1_overwrite_check",
"setup-push-read-scheduler": "20260924_191835_read_scheduler",
"setup-push-pull-schedule": "20260925_003029_pull_schedule,_turn_off_repeat_daily,_push_schedule",
"setup-push-multiday": "20260925_011907_send_multiday_schedule",
"call-home-enable-disable": "20260925_011620_ACH-change_1_setting",
"monitor-start-stop": "20260924_191214_turn_on_monitormode_then_attempt_to_write_config",
}
def _find(stem: str, kind: str) -> Path:
if "/" in stem:
sub, rest = stem.split("/", 1)
hits = sorted((CAP / sub).glob(f"raw_{kind}_{rest.lstrip('*')}.bin"))
else:
hits = sorted(CAP.glob(f"raw_{kind}_{stem}.bin"))
if len(hits) != 1:
raise SystemExit(f"expected one raw_{kind} file for {stem!r}, found {hits}")
return hits[0]
def requests(blob: bytes) -> list[bytes]:
out, i = [], 0
while i < len(blob):
if not (blob[i] == ACK and i + 1 < len(blob) and blob[i + 1] == STX):
i += 1
continue
j = i + 2
while j < len(blob):
if blob[j] == DLE and j + 1 < len(blob):
j += 2
continue
if blob[j] == ETX:
break
j += 1
out.append(blob[i:j + 1])
i = j + 1
return out
def main() -> None:
OUT.mkdir(parents=True, exist_ok=True)
for slug, stem in SESSIONS.items():
bw, s3 = _find(stem, "bw"), _find(stem, "s3")
reqs = requests(bw.read_bytes())
parser = MicromateFrameParser()
rsps = parser.feed(s3.read_bytes())
if len(reqs) != len(rsps):
raise SystemExit(f"{slug}: {len(reqs)} requests vs {len(rsps)} responses")
exchanges = []
lines = {rp.firmware_line for rp in rsps}
if len(lines) != 1 or lines & {"unknown"}:
raise SystemExit(f"{slug}: responses report firmware lines {sorted(lines)}")
for rq, rp in zip(reqs, rsps):
sub = request_sub(rq)
if rp.sub != 0xFF - sub or not rp.checksum_valid:
raise SystemExit(f"{slug}: response 0x{rp.sub:02X} does not answer 0x{sub:02X}")
exchanges.append({"sub": sub, "request": rq.hex(), "response_sub": rp.sub,
"response_data": rp.data.hex()})
doc = {
"source": str(bw.relative_to(REPO)),
"source_sha256": {"bw": hashlib.sha256(bw.read_bytes()).hexdigest(),
"s3": hashlib.sha256(s3.read_bytes()).hexdigest()},
"unit": "UM12947", "firmware_version": "11.0CB",
"firmware_line": lines.pop(),
"exchanges": exchanges,
}
(OUT / f"{slug}.json").write_text(json.dumps(doc, indent=1) + "\n")
print(f"{slug}: {len(exchanges)} exchanges")
if __name__ == "__main__":
main()
+90
View File
@@ -0,0 +1,90 @@
"""Ring-path bench test, Runs A/B: ask SFM for a Micromate's status on a fixed
interval and log every answer with its time. Read-only on the unit.
python scratch/ring_path_poller.py --sfm http://127.0.0.1:8299 \
--serial UM20147 --host <modem ip> --tcp-port 9034 --interval 10 \
--log <run dir>/poller.jsonl
Run A: --count 1 (one call-up; SFM then holds the line until its 5-minute idle
hang-up or a RADIO RING). Run B: the default, every --interval seconds until
Ctrl-C. Each poll asks for the raw SUB 0x49 code (run_state=true), so a
call-home in progress shows as its own code rather than as "not monitoring".
What the log is for (spec, "Open questions this design leaves for the bench"):
a 503 "call home in progress" is SFM seeing the ring and hanging up; a 503/504
on connect while THOR's watchdog holds the line is contention; THOR's own ACH
log says when the call reached THOR.
"""
from __future__ import annotations
import argparse
import datetime
import json
import time
import urllib.error
import urllib.parse
import urllib.request
def poll_once(sfm: str, serial: str, host: str, tcp_port: int, timeout: float) -> dict:
q = urllib.parse.urlencode({"serial": serial, "host": host, "tcp_port": tcp_port, "run_state": "true"})
t0 = time.monotonic()
started = datetime.datetime.now().isoformat(timespec="milliseconds")
try:
with urllib.request.urlopen(f"{sfm}/device/monitor/status?{q}", timeout=timeout) as r:
code, body = r.status, json.loads(r.read() or b"{}")
except urllib.error.HTTPError as e:
code = e.code
try:
body = json.loads(e.read() or b"{}")
except ValueError:
body = {}
except (urllib.error.URLError, TimeoutError, OSError) as e:
code, body = None, {"error": f"{type(e).__name__}: {e}"}
secs = round(time.monotonic() - t0, 2)
d = body.get("detail") if isinstance(body, dict) else None
rs = d.get("run_state") if isinstance(d, dict) else None # an error's detail is a string
return {"at": started, "secs": secs, "http": code,
"monitoring": body.get("monitoring") if isinstance(body, dict) else None,
"run_state": rs, "device_time": body.get("device_time") if isinstance(body, dict) else None,
"detail": None if code == 200 else (body.get("detail") or body.get("error"))}
def line(rec: dict) -> str:
rs = rec["run_state"]
state = f"0x{rs['code']:02X} {rs['name']}" if rs else "-"
tail = f" {rec['detail']}" if rec["detail"] else ""
return f"{rec['at']} http={rec['http']} {rec['secs']:>6} s 0x49={state} monitoring={rec['monitoring']}{tail}"
def main() -> None:
ap = argparse.ArgumentParser(description=__doc__.splitlines()[0])
ap.add_argument("--sfm", default="http://127.0.0.1:8299")
ap.add_argument("--serial", required=True)
ap.add_argument("--host", required=True)
ap.add_argument("--tcp-port", type=int, default=9034)
ap.add_argument("--interval", type=float, default=10.0, help="seconds between polls (start to start)")
ap.add_argument("--count", type=int, default=0, help="stop after N polls (0 = until Ctrl-C)")
ap.add_argument("--timeout", type=float, default=180.0)
ap.add_argument("--log", required=True, help="JSON lines, appended")
a = ap.parse_args()
if a.sfm.rstrip("/").endswith(":8200"):
raise SystemExit("refusing :8200 -- use the bench SFM")
n = 0
with open(a.log, "a") as f:
while True:
t0 = time.monotonic()
rec = poll_once(a.sfm.rstrip("/"), a.serial, a.host, a.tcp_port, a.timeout)
f.write(json.dumps(rec) + "\n"); f.flush()
print(line(rec), flush=True)
n += 1
if a.count and n >= a.count:
return
time.sleep(max(0.0, a.interval - (time.monotonic() - t0)))
if __name__ == "__main__":
try:
main()
except KeyboardInterrupt:
pass
+119
View File
@@ -0,0 +1,119 @@
#!/usr/bin/env python3
"""
socat_log_split.py — recover a capture pair from a `socat -x` relay log.
Why this exists
---------------
The bench relay that puts Thor in front of a USB-attached Micromate is:
socat -d -d -x TCP-LISTEN:12345,reuseaddr,fork /dev/ttyACM0,raw,echo=0,b115200 \
> ~/mm-captures/socat_<ts>.log 2>&1
`-x` makes socat hex-dump every byte it forwards, in both directions, with
timestamps. That log is therefore a **complete second copy of every capture**
taken through the relay — independent of whether seismo_lab was recording.
On 2026-09-25 that mattered: a capture's `.bin` files never made it off the
Windows machine, and the session was rebuilt from this log instead. When the
real bins turned up later, the reconstruction was **byte-for-byte identical in
both directions** (3,595 and 4,004 bytes). So this is a validated fallback, not
a lossy approximation.
Log format
----------
```
> 2026/09/25 00:30:35.000276659 length=21 from=0 to=20
41 02 10 10 00 5b 00 00 30 00 ...
2026/09/25 00:30:35 socat[32190] N write(5, 0x..., 21) completed
< 2026/09/25 00:30:35.000384100 length=64 from=0 to=63
02 00 c5 a4 00 00 30 00 ...
```
`>` is data heading toward the serial device (Thor → unit). `<` is data coming
back (unit → Thor). Hex lines are space-separated and indented; socat's own
status lines start with a date and carry no payload.
Usage
-----
# whole log
python scratch/socat_log_split.py socat_20260924_181248.log --out-dir ./recovered
# one session — line numbers from the "accepting connection" markers
grep -n "accepting connection" socat_*.log
python scratch/socat_log_split.py socat_*.log --from-line 919 --out-dir ./recovered
Then parse the result as usual:
python scratch/mm_frame_parse.py recovered/raw_bw.bin recovered/raw_s3.bin
⚠ A log spanning several sessions concatenates them. Split by line number using
the `accepting connection` markers, or the frame walk will run sessions together.
"""
from __future__ import annotations
import argparse
import re
from pathlib import Path
_HEX = re.compile(r"\A[0-9a-f]{2}\Z")
_SOCAT_STATUS = re.compile(r"\A\d{4}/\d{2}/\d{2}")
def split(lines) -> tuple[bytes, bytes]:
"""Return (to_device, from_device) byte streams."""
to_dev, from_dev = bytearray(), bytearray()
cur = None
for line in lines:
if line.startswith(">"):
cur = to_dev
continue
if line.startswith("<"):
cur = from_dev
continue
if _SOCAT_STATUS.match(line):
# socat's own status line ends the current dump block.
cur = None
continue
if cur is None or not line.startswith(" "):
continue
toks = line.split()
if toks and all(_HEX.match(t) for t in toks):
cur.extend(int(t, 16) for t in toks)
return bytes(to_dev), bytes(from_dev)
def main() -> int:
ap = argparse.ArgumentParser(
description=__doc__, formatter_class=argparse.RawDescriptionHelpFormatter
)
ap.add_argument("log", help="a socat -x log file")
ap.add_argument("--out-dir", default=".", help="where to write the .bin pair")
ap.add_argument("--from-line", type=int, default=1,
help="first log line to read (1-based) — use the "
"'accepting connection' marker of the session you want")
ap.add_argument("--to-line", type=int, default=None,
help="last log line to read (1-based, inclusive)")
ap.add_argument("--prefix", default="raw", help="output basename prefix")
args = ap.parse_args()
lines = Path(args.log).read_text(errors="replace").splitlines()
lo = max(args.from_line - 1, 0)
hi = args.to_line if args.to_line is not None else len(lines)
to_dev, from_dev = split(lines[lo:hi])
out = Path(args.out_dir)
out.mkdir(parents=True, exist_ok=True)
bw = out / f"{args.prefix}_bw.bin"
s3 = out / f"{args.prefix}_s3.bin"
bw.write_bytes(to_dev)
s3.write_bytes(from_dev)
print(f"Thor -> unit {len(to_dev):>7} bytes {bw}")
print(f"unit -> Thor {len(from_dev):>7} bytes {s3}")
if not to_dev or not from_dev:
print("⚠ one direction is empty — check --from-line / --to-line")
return 0
if __name__ == "__main__":
raise SystemExit(main())
+228
View File
@@ -0,0 +1,228 @@
#!/usr/bin/env python3
"""Verify the Thor / Micromate (series-4) IDF decoder against Thor's own exports.
Sister harness to ``scratch/verify_against_ascii.py`` (series-3 / Blastware).
Ground truth is the ``.IDFW.csv`` / ``.IDFH.csv`` file Thor writes next to each
binary, under a sibling ``CSV/`` directory:
<dir>/UM13981_20220207084555.IDFW
<dir>/CSV/UM13981_20220207084555.IDFW.csv
For waveforms the CSV carries a per-sample block of four columns
(Tran, Vert, Long, Mic) in in/s and psi -- i.e. true per-sample ground truth,
exactly what the BW ASCII exports give us for series-3. The leading 2-column
rows are the report header (PPV, sample rate, geo range, ...).
Usage:
python scratch/verify_thor_against_csv.py [--root DIR] [--lsb FLOAT]
[--limit N] [--kind idfw|idfh|both]
"""
from __future__ import annotations
import argparse
import csv
import os
import statistics
import sys
from collections import Counter, defaultdict
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from micromate import idf_file as M
DEFAULT_ROOT = "/home/serversdown/thor-watcher/example-data"
GEO = ("Tran", "Vert", "Long")
def parse_export(path):
"""Return (header_dict, sample_rows) from a Thor CSV export."""
hdr, rows = {}, []
with open(path, newline="", encoding="utf-8", errors="replace") as fh:
for rec in csv.reader(fh):
if len(rec) == 2:
hdr[rec[0].strip()] = rec[1].strip()
elif len(rec) >= 3:
try:
rows.append([float(x) for x in rec])
except ValueError:
pass
return hdr, rows
def index_corpus(root):
"""Map BASENAME.IDFW -> (binary_path, csv_path) for every paired file."""
exports, binaries = {}, {}
for dirpath, _dirs, files in os.walk(root):
for name in files:
up = name.upper()
full = os.path.join(dirpath, name)
if up.endswith(".IDFW.CSV") or up.endswith(".IDFH.CSV"):
exports.setdefault(name[:-4].upper(), full)
elif up.endswith(".IDFW") or up.endswith(".IDFH"):
binaries.setdefault(up, full)
return {k: (binaries[k], exports[k]) for k in binaries.keys() & exports.keys()}
def hdr_float(hdr, key):
raw = hdr.get(key)
if not raw:
return None
try:
return float(raw.split()[0])
except (ValueError, IndexError):
return None
def verify_waveform(binpath, csvpath, lsb):
"""Compare one IDFW against its export. Returns a result dict."""
out = {"file": os.path.basename(binpath), "status": "ok"}
try:
res = M.read_idf_file(binpath)
except NotImplementedError:
out["status"] = "not-thor"
return out
except Exception as exc: # noqa: BLE001 - harness reports, never raises
out["status"] = "decode-error"
out["detail"] = f"{type(exc).__name__}: {exc}"
return out
hdr, rows = parse_export(csvpath)
if not rows:
out["status"] = "no-gt-samples"
return out
gt = {ch: [r[i] for r in rows] for i, ch in enumerate(GEO)}
out["gt_len"] = len(rows)
out["geo_range"] = hdr.get("GeoRange")
exact = total = 0
lens, chan_status = {}, {}
ppv_err = {}
for ch in GEO:
arr = res.samples.get(ch, [])
ref = gt[ch]
lens[ch] = len(arr)
if len(arr) != len(ref):
chan_status[ch] = "length"
continue
if not arr:
chan_status[ch] = "empty"
continue
hits = sum(1 for c, v in zip(arr, ref) if abs(c * lsb - v) < 5e-5)
exact += hits
total += len(arr)
chan_status[ch] = "exact" if hits == len(arr) else "value"
gp = hdr_float(hdr, f"{ch}PPV")
if gp:
ppv_err[ch] = (max(abs(c) for c in arr) * lsb - gp) / gp
out["lens"] = lens
out["chan_status"] = chan_status
out["exact"] = exact
out["total"] = total
out["ppv_err"] = ppv_err
if all(v == "exact" for v in chan_status.values()):
out["status"] = "exact"
elif any(v == "length" for v in chan_status.values()):
out["status"] = "length-mismatch"
else:
out["status"] = "value-mismatch"
return out
def verify_histogram(binpath, csvpath, lsb):
out = {"file": os.path.basename(binpath), "status": "ok"}
try:
res = M.read_idf_file(binpath)
except NotImplementedError:
out["status"] = "not-thor"
return out
except Exception as exc: # noqa: BLE001
out["status"] = "decode-error"
out["detail"] = f"{type(exc).__name__}: {exc}"
return out
hdr, _rows = parse_export(csvpath)
out["n_intervals"] = len(res.intervals or [])
errs = {}
for ch, attr in (("Tran", "transverse_ips"), ("Vert", "vertical_ips"),
("Long", "longitudinal_ips")):
gp = hdr_float(hdr, f"{ch}PPV")
dv = getattr(res.event.peaks, attr, None)
if gp and dv:
errs[ch] = (dv - gp) / gp
out["ppv_err"] = errs
out["status"] = "peaks" if errs else "no-gt-peaks"
return out
def main():
ap = argparse.ArgumentParser()
ap.add_argument("--root", default=DEFAULT_ROOT)
ap.add_argument("--lsb", type=float, default=M._GEO_LSB_IPS)
ap.add_argument("--limit", type=int, default=0)
ap.add_argument("--kind", choices=("idfw", "idfh", "both"), default="both")
ap.add_argument("--show", type=int, default=15, help="worst-N detail rows")
args = ap.parse_args()
pairs = index_corpus(args.root)
keys = sorted(pairs)
if args.kind != "both":
keys = [k for k in keys if k.endswith(args.kind.upper())]
if args.limit:
keys = keys[: args.limit]
print(f"root: {args.root}")
print(f"geo LSB under test: {args.lsb!r} in/s per count")
print(f"paired files: {len(keys)}\n")
wf, hg = [], []
for k in keys:
binpath, csvpath = pairs[k]
if k.endswith(".IDFW"):
wf.append(verify_waveform(binpath, csvpath, args.lsb))
else:
hg.append(verify_histogram(binpath, csvpath, args.lsb))
if wf:
st = Counter(r["status"] for r in wf)
ex = sum(r.get("exact", 0) for r in wf)
tot = sum(r.get("total", 0) for r in wf)
print("=" * 68)
print(f"WAVEFORM (IDFW): {len(wf)} files")
for s, n in st.most_common():
print(f" {s:16} {n:5d} ({100*n/len(wf):5.1f}%)")
if tot:
print(f" per-sample exact: {ex}/{tot} = {100*ex/tot:.3f}%")
errs = [e for r in wf for e in r.get("ppv_err", {}).values()]
if errs:
print(f" PPV rel-error: median {statistics.median(errs):+.4%} "
f"mean {statistics.mean(errs):+.4%} "
f"max|.| {max(abs(e) for e in errs):.4%}")
bad = [r for r in wf if r["status"] not in ("exact",)]
if bad:
print(f"\n worst {min(args.show, len(bad))} of {len(bad)} non-exact:")
for r in bad[: args.show]:
print(f" {r['file']:42} {r['status']:16} "
f"lens={r.get('lens')} gt={r.get('gt_len')} "
f"{r.get('detail','')}")
if hg:
st = Counter(r["status"] for r in hg)
print("=" * 68)
print(f"HISTOGRAM (IDFH): {len(hg)} files")
for s, n in st.most_common():
print(f" {s:16} {n:5d} ({100*n/len(hg):5.1f}%)")
errs = [e for r in hg for e in r.get("ppv_err", {}).values()]
if errs:
print(f" PPV rel-error: median {statistics.median(errs):+.4%} "
f"mean {statistics.mean(errs):+.4%} "
f"max|.| {max(abs(e) for e in errs):.4%}")
within = lambda t: 100*sum(1 for e in errs if abs(e) <= t)/len(errs)
print(f" within 0.5%: {within(0.005):.1f}% "
f"within 2%: {within(0.02):.1f}% within 5%: {within(0.05):.1f}%")
return 0
if __name__ == "__main__":
raise SystemExit(main())
+5
View File
@@ -305,6 +305,11 @@ def main(argv=None) -> int:
default=0,
)
ev.total_samples = ev.total_samples or n_samp
# Sensor self-check traces from the IDFW fixed
# header, so regenerated .h5 files gain the v2
# /sensor_check group (mirrors save_imported_idf).
from micromate.sensor_check import decode_idf_sensor_check
ev.sensor_check = decode_idf_sensor_check(binary_bytes) or None
event_hdf5.write_event_hdf5(
hdf5_path, ev,
+93
View File
@@ -54,6 +54,7 @@ from s3_analyzer import ( # noqa: E402
write_claude_export,
)
from frame_db import FrameDB # noqa: E402
from minimateplus.binary_annotate import annotate_blastware_binary # noqa: E402
# ── colour palette ────────────────────────────────────────────────────────────
BG = "#1e1e1e"
@@ -2675,6 +2676,95 @@ class DownloadPanel(tk.Frame):
self._on_capture_ready(bw_path, s3_path, label)
# ─────────────────────────────────────────────────────────────────────────────
# Inspector panel — annotated hex view of a Series-3 binary
# ─────────────────────────────────────────────────────────────────────────────
class InspectorPanel(tk.Frame):
"""Load any Series-3 waveform binary and read it as an annotated hex dump.
Regions the decoder understands (header, STRT, per-channel sample records,
footer) are labelled and colour-coded; everything the decoder cannot account
for is flagged UNKNOWN, so undecoded bytes stand out for hand-inspection.
"""
_KIND_COLOR = {
"header": ACCENT,
"strt": YELLOW,
"sample": COL_S3,
"footer": FG_DIM,
"unknown": RED,
}
def __init__(self, parent: tk.Widget, initialdir=None, **kw) -> None:
super().__init__(parent, bg=BG, **kw)
self._path = None
self._initialdir = initialdir
self._build()
def _build(self) -> None:
bar = tk.Frame(self, bg=BG2)
bar.pack(side=tk.TOP, fill=tk.X)
tk.Button(bar, text="Open binary…", command=self._open, bg=BG3, fg=FG,
relief=tk.FLAT, font=MONO, activebackground=ACCENT).pack(side=tk.LEFT, padx=6, pady=6)
self._path_var = tk.StringVar(value="(no file loaded)")
tk.Label(bar, textvariable=self._path_var, bg=BG2, fg=FG_DIM, font=MONO).pack(side=tk.LEFT, padx=6)
self._summary_var = tk.StringVar(value="")
tk.Label(bar, textvariable=self._summary_var, bg=BG2, fg=FG, font=MONO).pack(side=tk.RIGHT, padx=10)
legend = tk.Frame(self, bg=BG2)
legend.pack(side=tk.TOP, fill=tk.X)
tk.Label(legend, text="legend:", bg=BG2, fg=FG_DIM, font=MONO).pack(side=tk.LEFT, padx=(8, 2))
for kind, color in self._KIND_COLOR.items():
tk.Label(legend, text=f"■ {kind}", bg=BG2, fg=color, font=MONO).pack(side=tk.LEFT, padx=5, pady=2)
self._text = scrolledtext.ScrolledText(
self, bg=BG, fg=FG, insertbackground=FG, font=MONO, wrap=tk.NONE, borderwidth=0)
self._text.pack(side=tk.TOP, fill=tk.BOTH, expand=True)
for kind, color in self._KIND_COLOR.items():
self._text.tag_configure(kind, foreground=color)
self._text.tag_configure("label", foreground="#ffffff", font=("Consolas", 9, "bold"))
self._text.tag_configure("dim", foreground=FG_DIM)
self._text.configure(state=tk.DISABLED)
def _open(self) -> None:
p = filedialog.askopenfilename(title="Open a Series-3 binary", initialdir=self._initialdir)
if p:
self.load(Path(p))
def load(self, path: Path) -> None:
try:
raw = path.read_bytes()
spans = annotate_blastware_binary(raw)
except Exception as e: # noqa: BLE001 — surface any read/annotate failure to the user
messagebox.showerror("Inspector", f"Failed to read/annotate:\n{path}\n\n{e}")
return
self._path = path
self._path_var.set(str(path))
self._render(raw, spans)
def _render(self, raw: bytes, spans) -> None:
t = self._text
t.configure(state=tk.NORMAL)
t.delete("1.0", tk.END)
unknown = sum(s.end - s.start for s in spans if s.kind == "unknown")
pct = 100 * unknown / max(1, len(raw))
self._summary_var.set(f"{len(raw)} B · {len(spans)} regions · {pct:.1f}% unknown")
for s in spans:
t.insert(tk.END, f"\n── {s.label} [0x{s.start:04x}:0x{s.end:04x}] {s.end - s.start} B ──\n", ("label",))
self._insert_hex(t, raw, s.start, s.end, s.kind)
t.configure(state=tk.DISABLED)
def _insert_hex(self, t: tk.Text, raw: bytes, start: int, end: int, kind: str) -> None:
for off in range(start, end, 16):
row = raw[off:min(off + 16, end)]
hx = " ".join(f"{b:02x}" for b in row).ljust(16 * 3 - 1)
txt = "".join(chr(b) if 32 <= b < 127 else "." for b in row)
t.insert(tk.END, f" 0x{off:04x} ", ("dim",))
t.insert(tk.END, hx, (kind,))
t.insert(tk.END, f" {txt}\n", ("dim",))
# ─────────────────────────────────────────────────────────────────────────────
# Main application window
# ─────────────────────────────────────────────────────────────────────────────
@@ -2730,6 +2820,9 @@ class SeismoLab(tk.Tk):
)
nb.add(self._download_panel, text=" Download ")
self._inspector_panel = InspectorPanel(nb)
nb.add(self._inspector_panel, text=" Inspector ")
self._nb = nb
self.protocol("WM_DELETE_WINDOW", self._on_close)
+16
View File
@@ -0,0 +1,16 @@
"""The SDM side of the device audit: DeviceAccess calls this sink, which writes
SeismoDb.device_commands. Kept here so sfm.device_access never imports the DB."""
from __future__ import annotations
from typing import Any, Callable
class DbAudit:
def __init__(self, get_db: Callable[[], Any]) -> None:
self._get_db = get_db
def begin(self, **fields: Any) -> str:
return self._get_db().begin_device_command(**fields)
def finish(self, command_id: str, **fields: Any) -> None:
self._get_db().finish_device_command(command_id, **fields)
+133
View File
@@ -0,0 +1,133 @@
"""USBM RI8507 / OSMRE blasting compliance chart.
Renders the velocity-vs-frequency compliance scatter Blastware draws on its Event
Report: each channel's significant waveform cycles as ``(frequency, peak
velocity)`` points on log-log axes against the regulatory limit curve(s). A point
below the curve passes; above fails.
Two pieces, kept separate so both can be reused/extended:
* ``limit_at`` / ``limit_curve`` — the regulatory limit curve(s), as data.
* ``channel_compliance_points`` — the per-cycle (freq, velocity) scatter, by
the zero-crossing method (matches Blastware: each channel's cloud tops out
at that channel's PPV).
Limit curves (USBM RI8507 Figure B-1 / OSM 30 CFR 816.67), drawn CONTINUOUS — a
constant-displacement bound (sloped, ``v = 2πf·d``) meets a constant-velocity
plateau at the frequency where they're equal, so there are no vertical steps
(matching how Blastware draws it). Two lines:
* **Drywall** (modern gypsum board) — 0.75 in/s plateau (solid).
* **Plaster** on wood lath (older homes) — 0.50 in/s plateau (dashed).
Both use a 0.030 in low-frequency displacement bound and rise through a 0.010 in
displacement bound to a 2.0 in/s high-frequency plateau. Values from USBM RI8507
(Appendix B) / 30 CFR 816.67; ⚠ confirm the exact shape against a Blastware
report before trusting for compliance.
"""
from __future__ import annotations
import math
from typing import Dict, Sequence, Tuple
import numpy as np
from matplotlib.ticker import FixedLocator, NullLocator
# curve name → (low-freq "ultimate" displacement in, mid velocity plateau in/s,
# high-freq displacement in, high-freq velocity plateau in/s).
# RI8507 Fig B-1 (p.74): ultimate max displacement 0.030 in (< ~4 Hz), plateau
# 0.75 (Drywall) / 0.50 (plaster), rising diagonal at 0.008 in displacement up to
# a 2.0 in/s plateau reached at ~40 Hz.
_CURVES: Dict[str, Tuple[float, float, float, float]] = {
"Drywall": (0.030, 0.75, 0.008, 2.00),
"Plaster": (0.030, 0.50, 0.008, 2.00),
}
# how each curve is stroked on the chart
_CURVE_STYLE = {"Drywall": {"ls": "-", "lw": 1.0}, "Plaster": {"ls": "--", "lw": 0.9}}
STANDARDS = tuple(_CURVES)
# Blastware's channel markers/colours on the compliance chart.
_CHANNEL_STYLE = {
"Tran": ("+", "#d62728"), # red +
"Vert": ("x", "#2ca02c"), # green x
"Long": ("o", "#1f77b4"), # blue o
}
def limit_at(freq_hz: float, curve: str = "Drywall") -> float:
"""Max allowed PPV (in/s) at ``freq_hz`` for ``curve`` (continuous)."""
d_low, v_mid, d_high, v_high = _CURVES[curve]
f = max(freq_hz, 1.0)
f_a = v_mid / (2.0 * math.pi * d_low) # disp_low → vel_mid
f_b = v_mid / (2.0 * math.pi * d_high) # vel_mid → disp_high
f_c = v_high / (2.0 * math.pi * d_high) # disp_high → vel_high
if f <= f_a:
return 2.0 * math.pi * f * d_low
if f <= f_b:
return v_mid
if f <= f_c:
return 2.0 * math.pi * f * d_high
return v_high
def limit_curve(curve: str = "Drywall", fmin: float = 1.0, fmax: float = 100.0, n: int = 400):
"""(freqs, limits) sampled across the band for plotting one curve."""
freqs = np.logspace(np.log10(fmin), np.log10(fmax), n)
return freqs, np.array([limit_at(f, curve) for f in freqs])
def channel_compliance_points(
samples: Sequence[float], sps: float, fmin: float = 1.0, fmax: float = 100.0,
vmin: float = 0.0,
) -> Tuple[np.ndarray, np.ndarray]:
"""Per-cycle (frequency, peak velocity) scatter for one channel.
Zero-crossing method: split the trace at sign changes; each half-cycle
contributes one point at ``(1/(2·half_period), max|amplitude|)``. Matches
Blastware — the cloud's ceiling is the channel PPV. ``samples`` must be in the
velocity unit you want plotted (in/s). Points outside ``[fmin, fmax]`` or at
or below ``vmin`` are dropped.
"""
x = np.asarray(samples, dtype=float)
if x.size < 3:
return np.empty(0), np.empty(0)
zc = np.where(np.diff(np.signbit(x)))[0]
freqs, vels = [], []
for a, b in zip(zc[:-1], zc[1:]):
half_period = (b - a) / sps
if half_period <= 0:
continue
freqs.append(1.0 / (2.0 * half_period))
vels.append(float(np.abs(x[a:b + 1]).max()))
f = np.array(freqs)
v = np.array(vels)
keep = (f >= fmin) & (f <= fmax) & (v > vmin)
return f[keep], v[keep]
def draw_compliance_chart(ax, channels: Dict[str, Sequence[float]], sps: float) -> None:
"""Draw the compliance chart (both limit curves + per-channel scatter)."""
for name, style in _CURVE_STYLE.items():
cf, cv = limit_curve(name)
ax.plot(cf, cv, color="#333", zorder=3, **style)
for ch, (marker, color) in _CHANNEL_STYLE.items():
samples = channels.get(ch)
if samples is None or len(samples) == 0:
continue
f, v = channel_compliance_points(samples, sps)
ax.scatter(f, v, marker=marker, s=12, c=color, linewidths=0.7, zorder=4, label=ch)
ax.set_xscale("log")
ax.set_yscale("log")
ax.set_xlim(1, 100)
ax.set_ylim(0.0394, 10)
ax.set_box_aspect(1) # square plot box (log-log compliance charts are square)
xt = [1, 2, 5, 10, 20, 50, 100]
yt = [0.0394, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10]
ax.xaxis.set_major_locator(FixedLocator(xt)); ax.xaxis.set_minor_locator(NullLocator())
ax.yaxis.set_major_locator(FixedLocator(yt)); ax.yaxis.set_minor_locator(NullLocator())
ax.set_xticklabels([str(v) for v in xt])
ax.set_yticklabels([("%g" % v) for v in yt])
ax.set_xlabel("Frequency (Hz)", fontsize=7)
ax.set_ylabel("Velocity (in/s)", fontsize=7)
ax.tick_params(labelsize=6)
ax.grid(True, which="both", ls=":", lw=0.4, color="#ccc")
+122
View File
@@ -34,6 +34,7 @@ Usage
from __future__ import annotations
import datetime
import json
import logging
import sqlite3
import uuid
@@ -126,6 +127,27 @@ CREATE TABLE IF NOT EXISTS monitor_log (
CREATE INDEX IF NOT EXISTS idx_monitor_log_serial ON monitor_log(serial);
CREATE INDEX IF NOT EXISTS idx_monitor_log_start ON monitor_log(start_time);
CREATE INDEX IF NOT EXISTS idx_monitor_log_session ON monitor_log(session_id);
CREATE TABLE IF NOT EXISTS device_commands (
id TEXT PRIMARY KEY,
ts TEXT NOT NULL, -- when the attempt began (UTC ISO)
-- ts/finished_ts: tz-aware UTC ISO (+00:00), unlike the naive UTC of older tables
finished_ts TEXT,
serial TEXT NOT NULL,
series INTEGER NOT NULL,
address TEXT NOT NULL,
action TEXT NOT NULL, -- e.g. "start monitoring"
tier TEXT NOT NULL, -- "change" | "destructive"
request TEXT, -- JSON: parameters + the planned frames (hex)
ack TEXT, -- JSON: ack summary
verified TEXT, -- "ok" | "mismatch" | "not_checked"
outcome TEXT NOT NULL, -- "pending" | "sent" | "skipped" | "failed"
error TEXT,
caller TEXT, -- "webapp" | "terra-view" | "script" | ...
sent INTEGER, -- did a frame go out: 1 acknowledged, 0 nothing sent, NULL unknown
states TEXT -- JSON: {"before": ..., "seen": [...], "after": ...}
);
CREATE INDEX IF NOT EXISTS idx_device_commands_serial ON device_commands(serial, ts);
"""
@@ -282,6 +304,17 @@ class SeismoDb:
log.info("_migrate: device_family backfill complete (remaining NULL=%d)",
remaining)
# Migration 1d: device_commands gained `sent` and `states` after the
# table first shipped on feat/series4-sfm-parity. NULLable, so rows
# written before read NULL (= unknown).
existing_cols = {
r[1] for r in conn.execute("PRAGMA table_info(device_commands)").fetchall()
}
for col, ddl in (("sent", "INTEGER"), ("states", "TEXT")):
if col not in existing_cols:
log.info("_migrate: device_commands ADD COLUMN %s %s", col, ddl)
conn.execute(f"ALTER TABLE device_commands ADD COLUMN {col} {ddl}")
# Migration 2: change monitor_log UNIQUE from (serial, waveform_key) to
# (serial, start_time) — same reasoning as events.
row = conn.execute(
@@ -372,6 +405,95 @@ class SeismoDb:
).fetchall()
return [dict(r) for r in rows]
# ── Device command audit ──────────────────────────────────────────────────
def begin_device_command(
self,
*,
serial: str,
series: int,
address: str,
action: str,
tier: str,
request: dict,
caller: str,
) -> str:
"""Write a ``pending`` audit row BEFORE anything is sent. Returns its id."""
cid = self._new_id()
ts = datetime.datetime.now(datetime.timezone.utc).isoformat()
with self._connect() as conn:
conn.execute(
"""
INSERT INTO device_commands
(id, ts, serial, series, address, action, tier,
request, outcome, caller)
VALUES (?, ?, ?, ?, ?, ?, ?, ?, 'pending', ?)
""",
(cid, ts, serial, series, address, action, tier,
json.dumps(request), caller),
)
return cid
def finish_device_command(
self,
command_id: str,
*,
outcome: str,
verified: Optional[str],
ack: Optional[dict],
error: Optional[str],
sent: Optional[int] = None,
states: Optional[dict] = None,
) -> None:
"""Record the result of a command begun with begin_device_command().
`sent`: 1 a frame went out and was acknowledged, 0 nothing was sent,
None unknown (the ack was lost). `states`: what was read from the unit,
``{"before": ..., "seen": [...], "after": ...}``.
"""
ts = datetime.datetime.now(datetime.timezone.utc).isoformat()
with self._connect() as conn:
cur = conn.execute(
"UPDATE device_commands SET finished_ts=?, outcome=?, verified=?, "
"ack=?, error=?, sent=?, states=? WHERE id=? AND outcome='pending'",
(ts, outcome, verified,
json.dumps(ack) if ack is not None else None,
error, sent,
json.dumps(states) if states is not None else None,
command_id),
)
if cur.rowcount == 0:
known = conn.execute(
"SELECT 1 FROM device_commands WHERE id=?",
(command_id,)).fetchone()
raise ValueError(
f"device command {command_id} "
+ ("is already finished" if known else "is unknown"))
def query_device_commands(
self,
serial: Optional[str] = None,
limit: int = 100,
) -> list[dict]:
"""Return audit rows, newest first, with request/ack/states parsed from JSON."""
with self._connect() as conn:
if serial:
rows = conn.execute(
"SELECT * FROM device_commands WHERE serial=? "
"ORDER BY ts DESC LIMIT ?", (serial, limit)).fetchall()
else:
rows = conn.execute(
"SELECT * FROM device_commands ORDER BY ts DESC LIMIT ?",
(limit,)).fetchall()
out = []
for r in rows:
d = dict(r)
for k in ("request", "ack", "states"):
if d[k] is not None:
d[k] = json.loads(d[k])
out.append(d)
return out
# ── Events ────────────────────────────────────────────────────────────────
def insert_events(
+13
View File
@@ -0,0 +1,13 @@
"""One door for every device request -- see the 2026-10-20 parity spec."""
from .errors import (
AuditIncomplete, AuditUnavailable, BadRequest, CallHomeInProgress, ChangeUnconfirmed,
ConnectFailed, DeviceError, EventNotFound, MalformedReply, NoAnswer, NotSupported, StaleEvent,
UnitBusy, UnitStateUnknown, WrongUnit, translate,
)
from .models import (
ChangeResult, DownloadedEvent, EventDownload, EventList, EventRef, UnitAddress, UnitInfo,
UnitSettings, UnitStatus,
)
from .series import normalise_serial, series_for_serial
from .locks import UnitLocks
from .access import DeviceAccess
+233
View File
@@ -0,0 +1,233 @@
"""DeviceAccess -- the one door every device request passes through.
The control surface does not care which series it is talking to; this does.
"""
from __future__ import annotations
import logging
import threading
import time
from typing import Any, Callable, Dict, Optional
from .errors import ConnectFailed, DeviceError, NoAnswer, NotSupported, WrongUnit
from .events import parse_event_id
from .locks import UnitLocks
from .models import ChangeResult, DownloadedEvent, EventList, UnitAddress, UnitInfo, UnitSettings, UnitStatus
from .s3 import Series3Adapter, default_s3_client_factory
from .s4 import (
Series4Session, default_s4_client_factory, s4_change_monitoring, s4_download_event, s4_identify, s4_list_events,
s4_settings, s4_status,
)
from .series import normalise_serial, series_for_serial
log = logging.getLogger("sfm.device_access")
class DeviceAccess:
def __init__(
self, *,
s3_client_factory: Callable[[UnitAddress], Any] = default_s3_client_factory,
s4_client_factory: Callable[[UnitAddress], Any] = default_s4_client_factory,
clock: Callable[[], float] = time.monotonic,
lock_timeout: float = 20.0,
keepalive_s: float = 60.0,
idle_hangup_s: float = 300.0,
reaper_interval_s: float = 5.0,
start_reaper: bool = True,
audit: Any = None,
sleep: Callable[[float], None] = time.sleep,
verify_timeout_s: float = 60.0,
verify_interval_s: float = 2.0,
) -> None:
if verify_interval_s <= 0 or verify_timeout_s < verify_interval_s:
raise ValueError("verify_interval_s must be > 0 and verify_timeout_s >= verify_interval_s")
self._audit = audit
self._sleep = sleep
self._verify_timeout_s = verify_timeout_s
self._verify_interval_s = verify_interval_s
self._locks = UnitLocks(lock_timeout)
self._s3 = Series3Adapter(s3_client_factory)
self._s4_factory = s4_client_factory
self._clock = clock
self._keepalive_s = keepalive_s
self._idle_hangup_s = idle_hangup_s
self._reaper_interval_s = reaper_interval_s
self._start_reaper = start_reaper
self._reaper: Optional[threading.Thread] = None
self._sessions: Dict[str, Series4Session] = {}
self._sessions_guard = threading.Lock()
# ── public operations ─────────────────────────────────────────────────────
def identify(self, address: UnitAddress, serial: str) -> UnitInfo:
return self._dispatch(address, serial, self._s3.identify, s4_identify)
def status(self, address: UnitAddress, serial: str, *, run_state: bool = False) -> UnitStatus:
"""`run_state` adds Series 4's raw SUB 0x49 code to `detail` (one more
round trip); Series 3 has no 0x49 and ignores it."""
return self._dispatch(address, serial, self._s3.status,
lambda client, s: s4_status(client, s, run_state=run_state))
def settings(self, address: UnitAddress, serial: str) -> UnitSettings:
return self._dispatch(address, serial, self._s3.settings, s4_settings)
def list_events(self, address: UnitAddress, serial: str) -> EventList:
return self._dispatch(address, serial, self._s3.list_events, s4_list_events)
def download_event(self, address: UnitAddress, serial: str, event_id: str) -> DownloadedEvent:
"""Read-only on the unit. Holds the unit for the whole download, so
other requests for it wait, then get 423."""
key, stamp = parse_event_id(event_id, serial) # BadRequest before any I/O
return self._dispatch(
address, serial,
lambda a, s: self._s3.download_event(a, s, key, stamp),
lambda c, s: s4_download_event(c, s, key, stamp))
def start_monitoring(self, address: UnitAddress, serial: str, *, dry_run: bool = False,
even_if_already: bool = False, caller: str = "api") -> ChangeResult:
return self._change_monitoring(address, serial, start=True, dry_run=dry_run,
even_if_already=even_if_already, caller=caller)
def stop_monitoring(self, address: UnitAddress, serial: str, *, dry_run: bool = False,
even_if_already: bool = False, caller: str = "api") -> ChangeResult:
return self._change_monitoring(address, serial, start=False, dry_run=dry_run,
even_if_already=even_if_already, caller=caller)
def _change_monitoring(self, address, serial, *, start, dry_run, even_if_already, caller):
serial = normalise_serial(serial)
series_for_serial(serial) # BadRequest (422) before the audit check
if not dry_run and self._audit is None:
raise NotSupported("no audit log is configured -- SFM refuses to change a unit "
"without one (nothing sent)")
kw = dict(start=start, dry_run=dry_run, even_if_already=even_if_already,
audit=self._audit, caller=caller, sleep=self._sleep,
verify_timeout_s=self._verify_timeout_s,
verify_interval_s=self._verify_interval_s)
return self._dispatch(
address, serial,
lambda a, s: self._s3.change_monitoring(a, s, **kw),
lambda c, s: s4_change_monitoring(c, s, address=address, **kw),
change=True)
def held_serial(self, address: UnitAddress) -> Optional[str]:
"""Serial of the OPEN held Series-4 line at this address, else None. No I/O."""
with self._sessions_guard:
session = self._sessions.get(address.key)
if session is not None and session.is_open:
return session.serial
return None
def hang_up(self, address: UnitAddress) -> bool:
with self._locks.hold(address.key):
with self._sessions_guard:
session = self._sessions.pop(address.key, None)
if session is None:
return False
was_open = session.is_open
session.hang_up()
return was_open
# ── dispatch ──────────────────────────────────────────────────────────────
def _dispatch(self, address: UnitAddress, serial: str,
s3_op: Callable[[UnitAddress, str], Any],
s4_op: Callable[[Any, str], Any], *, change: bool = False) -> Any:
serial = normalise_serial(serial)
series = series_for_serial(serial) # raises BadRequest before any I/O
with self._locks.hold(address.key):
if series == 3:
with self._sessions_guard:
held = self._sessions.get(address.key)
if held is not None and held.is_open:
raise WrongUnit(
f"a Series-4 line to {held.serial} is held at {address.key}; "
"a Series-3 unit cannot be there -- POST /device/hangup first "
"if the modem has moved")
return s3_op(address, serial)
session = self._session_for(address, serial)
was_held = session.is_open
try:
return session.run(lambda client: s4_op(client, serial))
except DeviceError as exc:
self._forget_if_closed(address, session)
# A held line the peer dropped still reads open (the transport only
# learns at EOF), so the first request on it times out or fails.
# Call up fresh and retry ONCE. Safe only because every operation
# here is a read (identify, status, settings, list, download -- all
# idempotent). A change (`change=True`) is never retried, by
# construction: a write whose ack was lost must never be sent twice.
if was_held and not change and isinstance(exc, (NoAnswer, ConnectFailed)):
self._drop(address.key, session)
session.hang_up()
session = self._session_for(address, serial)
try:
return session.run(lambda client: s4_op(client, serial))
except DeviceError:
self._forget_if_closed(address, session)
raise
raise
def _forget_if_closed(self, address: UnitAddress, session: Series4Session) -> None:
if not session.is_open:
self._drop(address.key, session)
def _session_for(self, address: UnitAddress, serial: str) -> Series4Session:
with self._sessions_guard:
session = self._sessions.get(address.key)
if session is not None and session.serial != serial:
if session.is_open:
raise WrongUnit(
f"a Series-4 line to {session.serial} is held at {address.key}; "
f"{serial} cannot be reached there -- POST /device/hangup first "
"if the modem has moved")
session = None
if session is None:
session = Series4Session(address, serial, self._s4_factory, clock=self._clock)
self._sessions[address.key] = session
self._ensure_reaper()
return session
# ── the reaper ────────────────────────────────────────────────────────────
def tick(self, now: Optional[float] = None) -> None:
"""Per held line: hang up if idle, else keep alive, else listen for a ring."""
now = self._clock() if now is None else now
with self._sessions_guard:
items = list(self._sessions.items())
for key, session in items:
with self._locks.try_hold(key) as held:
if not held:
continue # mid-request: not idle
if not session.is_open:
self._drop(key, session)
continue
try:
if now - session.last_used >= self._idle_hangup_s:
session.hang_up()
self._drop(key, session)
elif now - session.last_traffic >= self._keepalive_s:
session.keepalive()
else:
session.listen()
except DeviceError as exc:
log.warning("held line %s closed: %s", key, exc)
self._drop(key, session)
def _drop(self, key: str, session: Series4Session) -> None:
with self._sessions_guard:
if self._sessions.get(key) is session:
del self._sessions[key]
def _ensure_reaper(self) -> None:
if not self._start_reaper or self._reaper is not None:
return
self._reaper = threading.Thread(target=self._reaper_loop, name="sfm-held-lines", daemon=True)
self._reaper.start()
def _reaper_loop(self) -> None:
while True:
time.sleep(self._reaper_interval_s)
try:
self.tick()
except Exception: # noqa: BLE001
log.exception("held-line reaper tick failed")
+237
View File
@@ -0,0 +1,237 @@
"""The series-independent core of a start/stop request.
Identity -> state -> (dry run | skip | audit -> pre-send drain -> send once ->
read back -> audit). Each series supplies only its own pieces as callables:
how to read the serial, how to read the run-state name, how to send (returning
the ack record), how to recognise a refusal or a ring, and optionally what to
drain from the line just before sending. Nothing in here retries: `send` is
called at most once, and every path after `audit.begin` calls `audit.finish`
exactly once, through `finish` below.
Once the send has started, a failure is never reported as if nothing went out:
it is a `ChangeUnconfirmed` naming the audit row, carrying the status its cause
would have had. The row's `sent` column says whether a frame went out (1),
did not (0), or may have (NULL), and `states` keeps every state read.
The state names `calling_home` and `unknown*` are Series-4 states, except
`unknown(...)`, which Series 3 also produces for a flag byte never measured.
Series 3 never produces `calling_home` or a ring, so those branches are simply
never taken there.
"""
from __future__ import annotations
from typing import Any, Callable, Dict, List, NoReturn, Optional
from .errors import (
AuditIncomplete, AuditUnavailable, CallHomeInProgress, ChangeUnconfirmed, NotSupported,
UnitStateUnknown, WrongUnit, translate,
)
from .models import ChangeResult, UnitAddress
from .series import normalise_serial
CALL_HOME_MESSAGE = ("the unit started calling home; SFM hung up so the call can "
"reach THOR -- try again in a few minutes")
_HUNG_UP = "SFM hung up so the call can reach THOR"
# The row's `sent` column.
SENT_ACKNOWLEDGED, NOTHING_SENT, SENT_UNKNOWN = 1, 0, None
def _never(exc: BaseException) -> bool:
return False
def run_change(*, serial: str, series: int, start: bool, dry_run: bool, even_if_already: bool,
audit: Any, address: UnitAddress, caller: str,
sleep: Callable[[float], None], verify_timeout_s: float, verify_interval_s: float,
read_serial: Callable[[], str],
read_state: Callable[[], str],
describe_plan: Callable[[], Dict[str, Any]],
send: Callable[[], Dict[str, Any]],
is_refusal: Callable[[BaseException], bool] = _never,
is_ring: Callable[[BaseException], bool] = _never,
pre_send: Optional[Callable[[], None]] = None) -> ChangeResult:
action = "start monitoring" if start else "stop monitoring"
want = "monitoring" if start else "idle"
became = "started" if start else "stopped"
reported = normalise_serial(read_serial())
if reported != serial:
raise WrongUnit(f"asked for {serial} but {reported} answered at {address.key} -- "
"nothing sent")
before = read_state()
if before == "calling_home":
raise CallHomeInProgress(CALL_HOME_MESSAGE)
if before.startswith("unknown") and not dry_run:
raise UnitStateUnknown(f"the unit reports run state {before}, which has never "
"been measured -- nothing sent")
planned = dict(describe_plan(), sends_nothing=dry_run)
base = dict(serial=serial, series=series, action=action, plan=planned, state_before=before)
if dry_run:
return ChangeResult(dry_run=True, sent=False, outcome="dry_run",
verified="not_checked", state_after=None, audit_id=None, **base)
if audit is None:
raise NotSupported("no audit log is configured -- SFM refuses to change a unit "
"without one (nothing sent)")
request = {"plan": planned, "even_if_already": even_if_already}
try:
cid = audit.begin(serial=serial, series=series, address=address.key, action=action,
tier="change", request=request, caller=caller)
except Exception as exc: # noqa: BLE001
raise AuditUnavailable(
f"the audit log could not be written -- nothing sent: {exc}") from exc
def states(seen: List[str], after: Optional[str]) -> Dict[str, Any]:
return {"before": before, "seen": list(seen), "after": after}
def finish(unit: str, *, release_line: bool = False, **fields: Any) -> None:
"""The only way a row is finished. `unit` says what happened to the
unit, so a finish that fails still says it. `release_line` says whether
this path hangs up anyway, so a failed finish does not hold the line."""
try:
audit.finish(cid, **fields)
except Exception as exc: # noqa: BLE001
raise AuditIncomplete(
f"{unit} -- but audit record {cid} could not be finished: {exc}",
release_line=release_line) from exc
def unconfirmed(unit: str, cause: BaseException, *, went_out: str, status: int,
**fields: Any) -> NoReturn:
"""Finish the row, then say the change went out (or may have) and name it.
`went_out` is "acknowledged" or "unknown"; the row's `sent` follows it."""
finish(unit, release_line=True,
sent=SENT_ACKNOWLEDGED if went_out == "acknowledged" else SENT_UNKNOWN,
**fields)
raise ChangeUnconfirmed(f"{unit} -- audit record {cid}", audit_id=cid, sent=went_out,
http_status=status) from cause
def status_of(exc: BaseException) -> int:
return translate(exc, connecting=False).http_status
if before == want and not even_if_already:
finish(f"nothing was sent ({serial} is already {want})",
outcome="skipped", verified="not_checked", ack=None, error=f"already {want}",
sent=NOTHING_SENT, states=states([before], None))
return ChangeResult(dry_run=False, sent=False, outcome="skipped",
verified="not_checked", state_after=before,
audit_id=cid, detail={"reason": f"the unit is already {want}"}, **base)
if pre_send is not None:
try:
pre_send() # sends nothing: drains what is already waiting
except Exception as exc: # noqa: BLE001
if is_ring(exc):
finish("nothing was sent (a call-home began before sending)", release_line=True,
outcome="failed", verified="not_checked", ack=None,
error="a call-home began before sending -- nothing sent",
sent=NOTHING_SENT, states=states([before], None))
raise CallHomeInProgress(CALL_HOME_MESSAGE) from exc
finish(f"nothing was sent (the line failed before sending: {exc})", release_line=True,
outcome="failed", verified="not_checked", ack=None,
error=f"the line failed before sending -- nothing sent: {exc}",
sent=NOTHING_SENT, states=states([before], None))
raise # the link is suspect
try:
ack = send() # the only send; nothing below can reach it again
except Exception as exc: # noqa: BLE001 -- recorded, never retried
if is_refusal(exc): # refused by the gate: nothing went out
finish(f"nothing was sent (refused before sending: {exc})", release_line=True,
outcome="failed", verified="not_checked", ack=None,
error=f"refused before sending: {exc}",
sent=NOTHING_SENT, states=states([before], None))
raise
if is_ring(exc):
unconfirmed(f"{action} was sent, but a call-home began in place of the "
f"acknowledgement -- whether it {became} is unknown; {_HUNG_UP}",
exc, went_out="unknown", status=CallHomeInProgress.http_status,
outcome="failed", verified="not_checked", ack=None,
error=f"a call-home began in place of the ack: {exc}",
states=states([before], None))
try:
after: Optional[str] = read_state()
except Exception as follow: # noqa: BLE001
if is_ring(follow):
unconfirmed(f"{action} was sent but the acknowledgement was lost ({exc}), and "
f"the unit then began calling home -- whether it {became} is "
f"unknown; {_HUNG_UP}",
follow, went_out="unknown", status=CallHomeInProgress.http_status,
outcome="failed", verified="not_checked", ack=None,
error=f"no clean ack: {exc}; a call-home began: {follow}",
states=states([before], None))
unconfirmed(f"{action} was sent but the acknowledgement was lost ({exc}), and "
f"reading the state afterwards failed ({follow}) -- whether it "
f"{became} is unknown",
exc, went_out="unknown", status=status_of(exc),
outcome="failed", verified="not_checked", ack=None,
error=f"no clean ack: {exc}; the follow-up read failed: {follow}",
states=states([before], None))
if after == "calling_home":
unconfirmed(f"{action} was sent but the acknowledgement was lost ({exc}), and "
f"the unit then began calling home -- whether it {became} is "
f"unknown; {_HUNG_UP}",
exc, went_out="unknown", status=CallHomeInProgress.http_status,
outcome="failed", verified="not_checked", ack=None,
error=f"no clean ack: {exc}; the unit is now calling home",
states=states([before], after))
finish(f"{action} was sent but the acknowledgement was lost ({exc}); the unit "
f"now reads {after}",
outcome="failed", verified="not_checked", ack=None,
error=f"no clean ack: {exc}", sent=SENT_UNKNOWN, states=states([before], after))
return ChangeResult(dry_run=False, sent=True, outcome="failed",
verified="not_checked", state_after=after, audit_id=cid,
detail={"error": f"no clean ack: {exc}"}, **base)
seen = [before]
def last_poll() -> Optional[str]:
return seen[-1] if len(seen) > 1 else None
polls = int(verify_timeout_s // verify_interval_s)
try:
for _ in range(polls):
sleep(verify_interval_s)
seen.append(read_state())
if seen[-1] == want or seen[-1] == "calling_home":
break
except Exception as exc: # noqa: BLE001 -- the row must not stay pending
if is_ring(exc):
unconfirmed(f"{action} was sent and acknowledged, but the unit then began "
f"calling home before its state could be read back -- whether it "
f"{became} is unknown; {_HUNG_UP}",
exc, went_out="acknowledged", status=CallHomeInProgress.http_status,
outcome="sent", verified="not_checked", ack=ack,
error=f"sent and acknowledged; a call-home began while reading the "
f"state back: {exc}",
states=states(seen, last_poll()))
unconfirmed(f"{action} was sent and acknowledged, but reading the state back "
f"failed: {exc}",
exc, went_out="acknowledged", status=status_of(exc),
outcome="sent", verified="not_checked", ack=ack,
error=f"sent and acknowledged; reading the state back failed: {exc}",
states=states(seen, last_poll()))
if seen[-1] == "calling_home":
cause = CallHomeInProgress(CALL_HOME_MESSAGE)
unconfirmed(f"{action} was sent and acknowledged, but the unit then began calling "
f"home -- whether it {became} is unknown; {_HUNG_UP}",
cause, went_out="acknowledged", status=cause.http_status,
outcome="sent", verified="not_checked", ack=ack,
error="sent and acknowledged; the unit then began calling home",
states=states(seen, last_poll()))
ok = seen[-1] == want
outcome, verified = ("sent", "ok") if ok else ("failed", "mismatch")
error = None if ok else f"unit reads {seen[-1]}, expected {want}"
detail: Dict[str, Any] = {"states_seen": seen, "ack": ack}
if even_if_already and before == want:
note = (f"the unit was already {want} before sending; the read-back cannot show "
"that this send changed anything")
detail["note"] = note
if error is None:
error = note
finish(f"{action} was sent and verified" if ok else
f"{action} was sent and acknowledged, but the unit reads {seen[-1]}, not {want}",
outcome=outcome, verified=verified, ack=ack, error=error,
sent=SENT_ACKNOWLEDGED, states=states(seen, last_poll()))
return ChangeResult(dry_run=False, sent=True, outcome=outcome, verified=verified,
state_after=seen[-1], audit_id=cid, detail=detail, **base)
+116
View File
@@ -0,0 +1,116 @@
"""Typed device errors, each with the HTTP status the endpoints return."""
from __future__ import annotations
import micromate.protocol as _mm_proto
import minimateplus.protocol as _mmp_proto
class DeviceError(Exception):
http_status = 500
class BadRequest(DeviceError):
http_status = 422
class NotSupported(DeviceError):
http_status = 501
class WrongUnit(DeviceError):
http_status = 409
class UnitStateUnknown(DeviceError):
"""The unit reports a run state that has never been measured."""
http_status = 409
class AuditUnavailable(DeviceError):
"""The audit row could not be written, so nothing was sent."""
http_status = 503
class AuditIncomplete(DeviceError):
"""The unit was dealt with, but its audit row could not be finished. The
message says what happened to the unit first, then names the row.
`release_line` is True when the path would have hung up had the finish
worked (a ring, a link fault, a refusal): the failed write to the audit log
must not turn that into a held line, which would block a call-home."""
http_status = 500
def __init__(self, message: str, *, release_line: bool = False) -> None:
super().__init__(message)
self.release_line = release_line
class ChangeUnconfirmed(DeviceError):
"""A change failed after its frame went out, or may have gone out.
`sent` is "acknowledged" (the ack came back; the read-back failed) or
"unknown" (the ack was lost, or a call-home took its place). The status is
the one the cause would have had, set per instance, and the message names
the audit record. It never means "nothing was sent".
"""
http_status = 500
def __init__(self, message: str, *, audit_id: str, sent: str, http_status: int) -> None:
if sent not in ("acknowledged", "unknown"):
raise ValueError(f"sent must be 'acknowledged' or 'unknown', not {sent!r}")
super().__init__(message)
self.audit_id = audit_id
self.sent = sent
self.http_status = http_status
class UnitBusy(DeviceError):
http_status = 423
class ConnectFailed(DeviceError):
http_status = 503
class CallHomeInProgress(DeviceError):
http_status = 503
class NoAnswer(DeviceError):
http_status = 504
class MalformedReply(DeviceError):
http_status = 502
class EventNotFound(DeviceError):
http_status = 404
class StaleEvent(DeviceError):
"""The event at that key is not the one listed -- the unit was erased, or
its memory wrapped, since the list was read."""
http_status = 409
_TIMEOUTS = (_mm_proto.TimeoutError, _mmp_proto.TimeoutError)
_PROTOCOL = (_mm_proto.ProtocolError, _mmp_proto.ProtocolError)
def translate(exc: BaseException, *, connecting: bool) -> DeviceError:
"""Map a library exception to a typed error.
Order matters: each library's TimeoutError is a ProtocolError subclass, and
the builtin TimeoutError (a failed TCP connect) is an OSError.
"""
if isinstance(exc, DeviceError):
return exc
if isinstance(exc, _TIMEOUTS):
return NoAnswer(f"the unit did not answer: {exc}")
if isinstance(exc, _PROTOCOL):
return MalformedReply(f"bad reply from the unit: {exc}")
if isinstance(exc, OSError):
what = "could not connect" if connecting else "connection lost"
return ConnectFailed(f"{what}: {exc}")
return DeviceError(f"device error: {exc}")
+51
View File
@@ -0,0 +1,51 @@
"""Event identity. An `event_id` is `<serial>:<key hex>:<YYYYmmddHHMMSS>`.
The key alone is not enough: both series reuse keys (a MiniMate restarts at
01110000 after an erase; every Micromate's counter starts at the same value).
The timestamp turns a stale id into a loud StaleEvent instead of a download of
whatever now sits at that key. "-" stands in for an unknown timestamp.
"""
from __future__ import annotations
import datetime
from typing import Optional, Tuple
from .errors import BadRequest
from .series import normalise_serial
_NO_STAMP = "-"
_STAMP_FMT = "%Y%m%d%H%M%S"
def stamp_of(dt: Optional[datetime.datetime]) -> Optional[str]:
return dt.strftime(_STAMP_FMT) if dt is not None else None
def iso_of(dt: Optional[datetime.datetime]) -> Optional[str]:
return dt.isoformat() if dt is not None else None
def make_event_id(serial: str, key: bytes, stamp: Optional[str]) -> str:
return f"{normalise_serial(serial)}:{key.hex()}:{stamp or _NO_STAMP}"
def parse_event_id(event_id: str, serial: str) -> Tuple[bytes, Optional[str]]:
"""(key, stamp) for an id that belongs to `serial`; BadRequest otherwise."""
parts = (event_id or "").strip().split(":")
if len(parts) != 3:
raise BadRequest(f"not an event_id: {event_id!r} -- take it from GET /device/events")
id_serial, key_hex, stamp = parts
if normalise_serial(id_serial) != normalise_serial(serial):
raise BadRequest(f"event_id {event_id!r} belongs to {id_serial}, not {serial}")
try:
key = bytes.fromhex(key_hex)
except ValueError:
key = b""
if len(key) != 4:
raise BadRequest(f"event_id {event_id!r}: the key must be 8 hex digits")
if stamp != _NO_STAMP:
try:
datetime.datetime.strptime(stamp, _STAMP_FMT)
except ValueError:
raise BadRequest(f"event_id {event_id!r}: bad timestamp {stamp!r}") from None
return key, (None if stamp == _NO_STAMP else stamp)
+41
View File
@@ -0,0 +1,41 @@
"""One connection per unit. A modem allows a single TCP session, so two
requests must take turns instead of opening a second connection."""
from __future__ import annotations
import threading
from contextlib import contextmanager
from typing import Dict, Iterator, Optional
from .errors import UnitBusy
class UnitLocks:
def __init__(self, timeout: float = 20.0) -> None:
self._timeout = timeout
self._guard = threading.Lock()
self._locks: Dict[str, threading.Lock] = {}
def _lock_for(self, key: str) -> threading.Lock:
with self._guard:
return self._locks.setdefault(key, threading.Lock())
@contextmanager
def hold(self, key: str, timeout: Optional[float] = None) -> Iterator[None]:
lock = self._lock_for(key)
wait = self._timeout if timeout is None else timeout
if not lock.acquire(timeout=wait):
raise UnitBusy(f"the unit at {key} is busy with another request; try again shortly")
try:
yield
finally:
lock.release()
@contextmanager
def try_hold(self, key: str) -> Iterator[bool]:
lock = self._lock_for(key)
got = lock.acquire(blocking=False)
try:
yield got
finally:
if got:
lock.release()
+153
View File
@@ -0,0 +1,153 @@
"""Series-neutral models. Every operation returns the same shape for both
series; anything only one series has goes under `detail`."""
from __future__ import annotations
import datetime
from dataclasses import dataclass, field
from typing import Any, Dict, List, Optional
from .errors import BadRequest
@dataclass(frozen=True)
class UnitAddress:
host: Optional[str]
tcp_port: Optional[int]
port: Optional[str]
baud: Optional[int]
def __post_init__(self) -> None:
if not self.host and not self.port:
raise BadRequest(
"specify 'host' (TCP, e.g. ?host=10.0.0.5&tcp_port=9034) "
"or 'port' (serial, e.g. ?port=/dev/ttyACM0)"
)
@property
def key(self) -> str:
"""One key per physical link -- what the per-unit lock is keyed on."""
if self.host:
return f"tcp:{self.host}:{self.tcp_port}"
return f"serial:{self.port}"
@dataclass
class UnitInfo:
serial: str
series: int
model: Optional[str]
firmware: Optional[str]
monitoring: Optional[bool]
active_setup: Optional[str]
detail: Dict[str, Any] = field(default_factory=dict)
@dataclass
class UnitStatus:
serial: str
series: int
monitoring: bool
battery_volts: Optional[float]
memory_total_bytes: Optional[int]
memory_free_bytes: Optional[int]
device_time: Optional[str] # ISO, the unit's own local time
event_count: Optional[int] # None where it is not cheap (Series 3)
detail: Dict[str, Any] = field(default_factory=dict)
@dataclass
class UnitSettings:
serial: str
series: int
setup_name: Optional[str]
record_mode: Optional[str] # the unit's own name for its mode
sample_rate: Optional[int]
record_time_s: Optional[float]
histogram_interval_s: Optional[int]
geo_trigger_ips: Optional[float]
notes: Dict[str, str] = field(default_factory=dict)
detail: Dict[str, Any] = field(default_factory=dict)
@dataclass
class EventRef:
"""One stored event, as listed. `event_id` is opaque: pass it back to
download the event. `index` is its position in the list right now; an
erase renumbers it, so it is for display, never identity."""
event_id: str
serial: str
series: int
index: int
timestamp: Optional[str] # ISO, the unit's own local time
record_type: Optional[str] # "waveform" | "histogram"
peak_vector_sum_ips: Optional[float]
peaks_ips: Dict[str, float] # geophones only: tran / vert / long
filename: Optional[str] # the name the vendor's software gives it
detail: Dict[str, Any] = field(default_factory=dict)
@dataclass
class EventList:
serial: str
series: int
events: List[EventRef]
detail: Dict[str, Any] = field(default_factory=dict)
@dataclass
class EventDownload:
"""What a download stored. The file and waveform are then served at
/db/events/{db_event_id}/... ."""
event_id: str
serial: str
series: int
db_event_id: Optional[str]
stored_filename: str
filesize: Optional[int] # None only for a stored row with no file recorded
sha256: Optional[str] # None when the event was already stored
inserted: bool # False: already stored; nothing was written (detail.already_stored)
verified: Optional[bool] # True: decode self-check passed; None: no check exists
detail: Dict[str, Any] = field(default_factory=dict)
@dataclass
class DownloadedEvent:
"""The device side's result, before SFM stores it. Not an HTTP shape: it
carries the payload -- a Series-3 Event + its 5A frames + the compliance
config, or a Series-4 file's bytes -- to sfm.event_ingest.
`timestamp` is the event's time as the unit reported it: the store looks up
an existing row by (serial, timestamp) before writing anything. `record` is
what the unit's own event record said (Series 4's 0x0C), for the fields the
file alone does not give."""
event_id: str
serial: str
series: int
filename: str
verified: Optional[bool]
idf_bytes: Optional[bytes] = field(default=None, repr=False)
event: Any = field(default=None, repr=False)
a5_frames: Optional[list] = field(default=None, repr=False)
compliance: Any = field(default=None, repr=False)
timestamp: Optional[datetime.datetime] = None
record: Dict[str, Any] = field(default_factory=dict)
detail: Dict[str, Any] = field(default_factory=dict)
@dataclass
class ChangeResult:
"""The outcome of a change request. `outcome`: "dry_run" | "skipped" | "sent" |
"failed". `verified`: "ok" | "mismatch" | "not_checked". `plan` is the exact
frames planned (dry run) or sent."""
serial: str
series: int
action: str
dry_run: bool
sent: bool
outcome: str
verified: str
state_before: Optional[str]
state_after: Optional[str]
audit_id: Optional[str]
plan: Dict[str, Any] = field(default_factory=dict)
detail: Dict[str, Any] = field(default_factory=dict)
+387
View File
@@ -0,0 +1,387 @@
"""Series-3 adapter. Connect-per-request, as SFM has always done for
MiniMates -- a held session waits for the bench test in the spec."""
from __future__ import annotations
import datetime
import logging
import struct
from typing import Any, Callable, Optional
from minimateplus import MiniMateClient
from minimateplus.blastware_file import blastware_filename
from minimateplus.event_file_io import _GEO_INT16_FS
from minimateplus.framing import build_bw_write_frame
from minimateplus.protocol import SUB_START_MONITORING, SUB_STOP_MONITORING
from minimateplus.transport import TcpTransport
from .errors import DeviceError, EventNotFound, MalformedReply, NoAnswer, StaleEvent, WrongUnit, translate
from .change import run_change
from .events import iso_of, make_event_id, stamp_of
from .models import ChangeResult, DownloadedEvent, EventList, EventRef, UnitAddress, UnitInfo, UnitSettings, UnitStatus
log = logging.getLogger("sfm.device_access")
S3_DEFAULT_BAUD = 38400
S3_MODES = {0x00: "Single Shot", 0x01: "Continuous", 0x03: "Histogram", 0x04: "Histogram + Continuous"}
S3_EVENT_TIMEOUT = 120.0 # what the legacy event-download routes use
# The 0x1C flag byte (section[1]): the only values ever measured. 0x10 is
# BE11529 monitoring (2026-04-08); 0x0B is BE9441 recording a histogram,
# confirmed at the unit (2026-10-26). Anything else is refused for a change.
S3_RUN_STATES = {0x00: "idle", 0x10: "monitoring", 0x0B: "monitoring"}
def s3_run_state(status: Any) -> str:
"""The change path's state name from the raw 0x1C flag -- never
`is_monitoring`, which reads every byte but 0x10 as idle. A value never
measured is `unknown(0x..)`, and the change core refuses it."""
flag = getattr(status, "state_flag", None)
if flag is None:
return "unknown(short)"
return S3_RUN_STATES.get(flag, f"unknown(0x{flag:02X})")
# A start makes the unit run its sensor check before "Recording..." -- ~30 s
# (Brian, 2026-10-26), ~40 s on BE11529 (2026-04-08). A start's read-back waits
# this long before asking, then wakes the unit with retries (S3_WAKE_*).
S3_SENSOR_CHECK_S = 30.0
S3_WAKE_ATTEMPT_S = 5.0
S3_WAKE_DEADLINE_S = 60.0
def _woken_state(client: Any) -> str:
"""The run state, read after waking the unit: SESSION_RESET + POLL first,
re-sent until it answers.
A monitoring MiniMate ignores a bare request until it is woken (measured
2026-04-08). On 2026-10-26 BE9441 acked a start, then left a bare 0x1C, and
later a single SESSION_RESET + POLL, unanswered for 120 s: both went out 2 s
after the start, inside the sensor check, and were never re-sent."""
client.wake(attempt_s=S3_WAKE_ATTEMPT_S, deadline_s=S3_WAKE_DEADLINE_S)
return s3_run_state(client.get_monitor_status())
def default_s3_client_factory(address: UnitAddress, timeout: Optional[float] = None) -> MiniMateClient:
if address.host:
return MiniMateClient(transport=TcpTransport(address.host, port=address.tcp_port),
timeout=10.0 if timeout is None else timeout)
if timeout is None:
return MiniMateClient(address.port, address.baud or S3_DEFAULT_BAUD)
return MiniMateClient(address.port, address.baud or S3_DEFAULT_BAUD, timeout=timeout)
def _close(client: Any) -> None:
try:
client.close()
except Exception: # noqa: BLE001
log.debug("close failed", exc_info=True)
def _s3_dt(ev: Any) -> Optional[datetime.datetime]:
ts = getattr(ev, "timestamp", None)
if ts is None or ts.hour is None:
return None
try:
return datetime.datetime(ts.year, ts.month, ts.day, ts.hour, ts.minute, ts.second)
except (TypeError, ValueError):
return None
def _s3_filename(ev: Any, serial: str) -> Optional[str]:
try:
return blastware_filename(ev, serial)
except Exception: # noqa: BLE001
return None
S3_RECORD_TYPE_NOTE = "Series 3's event record does not say waveform or histogram; not decoded yet"
def _s3_ref(ev: Any, serial: str) -> EventRef:
"""record_type is always None: minimateplus's 0C decode reports "Waveform"
for every record layout, histograms included, so it cannot be trusted
here. Null rather than wrong until a histogram's 0C is captured."""
dt = _s3_dt(ev)
pv = ev.peak_values
peaks = {}
if pv is not None:
peaks = {k: v for k, v in (("tran", pv.tran), ("vert", pv.vert), ("long", pv.long))
if v is not None}
return EventRef(
event_id=make_event_id(serial, ev._waveform_key, stamp_of(dt)),
serial=serial, series=3, index=ev.index, timestamp=iso_of(dt),
record_type=None,
peak_vector_sum_ips=pv.peak_vector_sum if pv is not None else None,
peaks_ips=peaks, filename=_s3_filename(ev, serial),
detail={"mic_psi": pv.micl if pv is not None else None,
"record_type_note": S3_RECORD_TYPE_NOTE},
)
_GEO_FULL_SCALE_IPS = 10.0 # normal range; one decoder step = 0.005 in/s
_PEAK_TOLERANCE_IPS = 0.0051 # one 0.005 in/s step, plus the 0C's float32 slop
def verify_s3_download(ev: Any, compliance: Any, body: Optional[bytes] = None) -> tuple:
"""Check a downloaded event against itself and the unit's own 0C record: (verified, why).
A short or misassembled event must not reach the store -- BE9441's bench
(2026-10-25) stored two as successes before this existed. `body` is the
event's 5A body (taken from `ev._a5_frames` when not given). In order:
* No waveform decode: it must decode as a histogram (stored unverified --
its peaks are not compared yet), or it is refused. 0 of ~430 fixture
histograms decode as a waveform; a corrupted waveform decodes as neither.
* A waveform's record chain must end on its END record (0x06), as the
file reader requires; a cut-short stream does not.
* All three geophone channels must be the same length.
* Each channel's peak must be the unit's own to one 0.005 in/s step (a
clipped blast -- both at full scale -- counts as a match). Only for a
unit confirmed in normal range: a sensitive-range unit's scale is still
open (the 8x discrepancy), and an unread range is not assumed.
Raises MalformedReply ("not saved") on any failure.
"""
from minimateplus.blastware_file import extract_body_bytes
from minimateplus.histogram_codec import decode_histogram_body
from minimateplus.waveform_codec import STREAM_END_ID, walk_records
if body is None:
frames = getattr(ev, "_a5_frames", None)
body = extract_body_bytes(frames)[1] if frames else b""
samples = getattr(ev, "raw_samples", None) or {}
chans = ("Tran", "Vert", "Long")
if not all(samples.get(c) for c in chans):
if body and decode_histogram_body(body):
return None, "a histogram: stored unverified (its peaks are not compared yet)"
raise MalformedReply(
"the downloaded event decodes as neither a waveform nor a histogram -- the "
"download is incomplete or misassembled; not saved")
try:
recs = walk_records(body)
except Exception: # noqa: BLE001 -- treated as no chain
recs = []
tail = recs[-1]["end"] if recs else None
if tail is None or tail + 5 > len(body) or body[tail + 4] != STREAM_END_ID:
raise MalformedReply(
"the downloaded waveform's record chain has no end record -- the download is "
"cut short; not saved")
lengths = {c: len(samples[c]) for c in chans}
if len(set(lengths.values())) != 1:
raise MalformedReply(
f"the downloaded waveform's channels have different lengths {lengths} -- the "
"download is incomplete or misassembled; not saved")
if getattr(compliance, "geo_range", None) != 0:
return None, ("whole, but peaks not checked: the unit is not confirmed in normal "
"range (a sensitive-range scale is not settled)")
pv = ev.peak_values
unit = {"Tran": pv.tran, "Vert": pv.vert, "Long": pv.long} if pv else {}
clip = _GEO_FULL_SCALE_IPS - _PEAK_TOLERANCE_IPS
for c in chans:
if unit.get(c) is None:
return None, f"whole, but the unit's record gives no {c} peak to check against"
decoded = max(abs(x) for x in samples[c]) * _GEO_FULL_SCALE_IPS / _GEO_INT16_FS
if decoded >= clip and unit[c] >= clip:
continue # both at full scale: a clipped blast
if abs(decoded - unit[c]) > _PEAK_TOLERANCE_IPS:
raise MalformedReply(
f"the downloaded {c} peak is {decoded:.4f} in/s but the unit's own record says "
f"{unit[c]:.4f} -- the download is incomplete or misassembled; not saved")
return True, f"{lengths['Tran']} samples per channel, peaks match the unit's own"
class Series3Adapter:
def __init__(self, client_factory: Callable[..., Any] = default_s3_client_factory) -> None:
self._factory = client_factory
def change_monitoring(self, address: UnitAddress, serial: str, *, start: bool, dry_run: bool,
even_if_already: bool, audit: Any, caller: str,
sleep: Callable[[float], None], verify_timeout_s: float,
verify_interval_s: float) -> ChangeResult:
"""Series-3 pieces for the shared core in change.py. One attempt, never
retried: `retry=False` stops _run's cold-boot second attempt, and the
core calls the write once."""
sub = SUB_START_MONITORING if start else SUB_STOP_MONITORING
ack_sub = 0xFF - sub
def op(client: Any) -> ChangeResult:
def read_serial() -> str:
info = client.connect() # a fresh connection: connect() is the fresh 0x15 read
return info.serial or ""
def describe_plan() -> dict:
what = "start monitoring" if start else "stop monitoring"
return {"action": what, "sends_nothing": True, "warnings": [],
"steps": [{"sub": f"0x{sub:02X}", "what": what, "offset": "0x0000",
"data_len": 0, "expect_ack": f"0x{ack_sub:02X}",
"frame": build_bw_write_frame(sub, b"").hex()}]}
settle: list = []
def send() -> dict:
# The client validates the ack SUB; it returns nothing else, so none is claimed.
(client.start_monitoring if start else client.stop_monitoring)()
if start:
settle.append(S3_SENSOR_CHECK_S) # the first read waits out the check
return {"subs": [f"0x{ack_sub:02X}"]}
def read_state() -> str:
if settle:
sleep(settle.pop())
return _woken_state(client)
return run_change(
serial=serial, series=3, start=start, dry_run=dry_run,
even_if_already=even_if_already, audit=audit, address=address, caller=caller,
sleep=sleep, verify_timeout_s=verify_timeout_s, verify_interval_s=verify_interval_s,
read_serial=read_serial,
read_state=read_state,
describe_plan=describe_plan, send=send)
return self._run(address, op, timeout=S3_EVENT_TIMEOUT, retry=False)
def _run(self, address: UnitAddress, fn: Callable[[Any], Any], timeout: Optional[float] = None,
retry: bool = True) -> Any:
def attempt() -> Any:
client = self._factory(address) if timeout is None else self._factory(address, timeout=timeout)
try:
client.open()
except Exception as exc:
_close(client)
raise translate(exc, connecting=True) from exc
try:
return fn(client)
except DeviceError:
raise
except Exception as exc:
raise translate(exc, connecting=False) from exc
finally:
_close(client)
try:
return attempt()
except NoAnswer:
# A MiniMate that has just had its serial lines asserted can take
# 5-10 s to boot, and shows it as silence; one retry covers it. TCP
# only -- on a serial cable a silence is a real fault. Narrower than
# server._run_with_retry (any protocol error): retrying a
# MalformedReply would also retry "no settings block", which a
# reconnect cannot fix.
if not retry or not address.host:
raise
log.info("Series 3 at %s: no clean answer, retrying once (unit may be cold)", address.key)
return attempt()
@staticmethod
def _check(serial_reported: str, serial: str, address: UnitAddress) -> None:
if (serial_reported or "").strip().upper() != serial:
raise WrongUnit(f"asked for {serial} but {serial_reported} answered at {address.key}")
def identify(self, address: UnitAddress, serial: str) -> UnitInfo:
def op(client: Any) -> UnitInfo:
info = client.connect()
self._check(info.serial, serial, address)
cc = info.compliance_config
return UnitInfo(
serial=info.serial, series=3, model=info.model, firmware=info.firmware_version,
monitoring=None, active_setup=cc.setup_name if cc else None,
detail={"manufacturer": info.manufacturer, "dsp_version": info.dsp_version},
)
return self._run(address, op)
def status(self, address: UnitAddress, serial: str) -> UnitStatus:
def op(client: Any) -> UnitStatus:
client.poll()
ms = client.get_monitor_status()
# The change path's reading, not a guess: an unmeasured flag is None.
monitoring = {"monitoring": True, "idle": False}.get(s3_run_state(ms))
return UnitStatus(
serial=serial, series=3, monitoring=monitoring,
battery_volts=round(ms.battery_v, 2) if ms.battery_v is not None else None,
memory_total_bytes=ms.memory_total, memory_free_bytes=ms.memory_free,
device_time=None, event_count=None,
# Series 3 status reads no serial, so the serial shown is the one requested, not one the unit reported.
detail={"serial_verified": False},
)
return self._run(address, op)
def settings(self, address: UnitAddress, serial: str) -> UnitSettings:
def op(client: Any) -> UnitSettings:
info = client.connect()
self._check(info.serial, serial, address)
cc = info.compliance_config
if cc is None:
raise MalformedReply("could not read the unit's settings (SUB 0x1A)")
mode = None
if cc.recording_mode is not None:
mode = S3_MODES.get(cc.recording_mode, f"unknown (0x{cc.recording_mode:02x})")
notes = {
label: value for label, value in (
("Project", cc.project), ("Client", cc.client), ("User Name", cc.operator),
("Seis Loc", cc.sensor_location), ("Extended Notes", cc.notes),
) if value is not None
}
return UnitSettings(
serial=info.serial, series=3, setup_name=cc.setup_name, record_mode=mode,
sample_rate=cc.sample_rate, record_time_s=cc.record_time,
histogram_interval_s=cc.histogram_interval_sec, geo_trigger_ips=cc.trigger_level_geo,
notes=notes,
detail={"record_mode_code": cc.recording_mode, "alarm_level_geo": cc.alarm_level_geo,
"geo_range": cc.geo_range},
)
return self._run(address, op)
def list_events(self, address: UnitAddress, serial: str) -> EventList:
def op(client: Any) -> EventList:
info = client.connect()
self._check(info.serial, serial, address)
return EventList(serial=serial, series=3,
events=[_s3_ref(ev, serial) for ev in client.list_event_headers()])
# The default timeout: a header walk is small replies only, so a lost
# one costs 10 s (TCP) with the unit locked, not 120 s.
return self._run(address, op)
def download_event(self, address: UnitAddress, serial: str, key: bytes,
stamp: Optional[str]) -> DownloadedEvent:
# The walk compares this with the target's 0C and, on a mismatch, sends
# no 5A: a stale id costs a header walk, not a full download of the
# wrong event.
iso = datetime.datetime.strptime(stamp, "%Y%m%d%H%M%S").isoformat() if stamp is not None else None
def op(client: Any) -> DownloadedEvent:
info = client.connect()
self._check(info.serial, serial, address)
try:
ev = client.download_event_by_key(key, expected_timestamp=iso)
except struct.error as exc:
# Defensive. This once caught the 64 KB page bug (TERM's offset driven
# negative); the walk is 32-bit linear since 2026-10-26 and no longer
# produces it, so reaching here is a new fault.
raise MalformedReply(
f"event {key.hex()}: its download could not be assembled ({exc}); not saved"
) from exc
if ev is None:
raise EventNotFound(f"no event {key.hex()} on {serial} -- list the events again")
found = stamp_of(_s3_dt(ev))
if stamp is not None and found is None:
raise MalformedReply(
f"could not read event {key.hex()}'s record (0C) to confirm it is the one "
"listed -- not downloaded; try again")
if stamp is not None and found != stamp:
raise StaleEvent(
f"the event at {key.hex()} on {serial} is from {found}, not {stamp} -- "
"the unit was erased or wrapped since the list was read; list again")
if not ev._a5_frames:
raise MalformedReply(f"event {key.hex()}: no waveform data received (the 5A download failed)")
filename = _s3_filename(ev, serial)
if filename is None:
raise MalformedReply(f"event {key.hex()} has no usable timestamp, so it cannot be named or stored")
verified, why = verify_s3_download(ev, info.compliance_config)
return DownloadedEvent(
event_id=make_event_id(serial, key, found), serial=serial, series=3,
filename=filename, verified=verified, event=ev, a5_frames=ev._a5_frames,
compliance=info.compliance_config, timestamp=_s3_dt(ev),
detail={"a5_frames": len(ev._a5_frames), "check": why},
)
return self._run(address, op, timeout=S3_EVENT_TIMEOUT)
+371
View File
@@ -0,0 +1,371 @@
"""Series-4 sessions: call up once, stay on the line, hang up when idle.
⚠ **This module hosts a write path.** `s4_change_monitoring` is the Series-4
wrapper of the shared change core (`change.run_change`): it sends `0x96` /
`0x97` through `MicromateProtocol.execute()`, and it is the only caller of
`.protocol.execute(` in the codebase (a test pins that). Everything else here
is a read.
⚠ Imports only minimateplus.transport from the Series-3 package. Nothing
here may build or send a Series-3 frame -- SESSION_RESET (41 03) has never
been sent to a Micromate.
"""
from __future__ import annotations
import logging
import time
from typing import Any, Callable, Optional, TypeVar
from micromate.client import MicromateClient
from micromate.opcodes import OpcodeRefused
from micromate.protocol import THOR_CHUNK_SIZE
from micromate.writes import plan_start_monitoring, plan_stop_monitoring
from minimateplus.transport import BaseTransport, SerialTransport, TcpTransport
from .errors import (
AuditIncomplete, CallHomeInProgress, ChangeUnconfirmed, DeviceError, EventNotFound,
MalformedReply, StaleEvent, WrongUnit, translate,
)
from .change import CALL_HOME_MESSAGE, run_change
from .events import iso_of, make_event_id, stamp_of
from .models import ChangeResult, DownloadedEvent, EventList, EventRef, UnitAddress, UnitInfo, UnitSettings, UnitStatus
from .series import normalise_serial
log = logging.getLogger("sfm.device_access")
T = TypeVar("T")
RING = b"RADIO RING"
S4_DEFAULT_BAUD = 115200
class RingDetected(Exception):
"""The unit sent RADIO RING: it is calling home up this connection."""
class RingWatchTransport(BaseTransport):
"""Passes bytes through; raises RingDetected the moment RADIO RING appears
OUTSIDE a frame, including when it is split across two reads.
Inside a frame the bytes are data: the 0x2C call-home config block's dial
string is literally "RADIO RING". A frame runs from STX to an unescaped
ETX; inside it DLE escapes the next byte.
"""
_STX, _ETX, _DLE = 0x02, 0x03, 0x10
def __init__(self, inner: BaseTransport) -> None:
self._inner = inner
self._tail = b""
self._in_frame = False
self._escaped = False
def connect(self) -> None:
self._inner.connect()
def disconnect(self) -> None:
self._inner.disconnect()
@property
def is_connected(self) -> bool:
return self._inner.is_connected
def write(self, data: bytes) -> None:
# A request starts a new exchange (MicromateProtocol resets its parser
# here too), so a stray STX on an idle line cannot hide the next ring.
self._in_frame = self._escaped = False
self._inner.write(data)
def read(self, n: int) -> bytes:
data = self._inner.read(n)
for b in data:
if self._in_frame:
if self._escaped:
self._escaped = False
elif b == self._DLE:
self._escaped = True
elif b == self._ETX:
self._in_frame = False
elif b == self._STX:
self._in_frame = True
self._tail = b""
else:
self._tail = (self._tail + bytes([b]))[-len(RING):]
if self._tail == RING:
self._tail = b""
raise RingDetected("RADIO RING")
return data
def default_s4_client_factory(address: UnitAddress, recv_timeout: float = 10.0) -> MicromateClient:
if address.host:
inner: BaseTransport = TcpTransport(address.host, port=address.tcp_port)
else:
inner = SerialTransport(address.port, address.baud or S4_DEFAULT_BAUD)
return MicromateClient(RingWatchTransport(inner), recv_timeout=recv_timeout)
def _close(client: Any) -> None:
try:
client.close()
except Exception: # noqa: BLE001
log.debug("close failed", exc_info=True)
_RING_MESSAGE = CALL_HOME_MESSAGE
class Series4Session:
"""One held line to one Micromate.
`last_used` is the last *user* request: the idle hang-up measures it.
`last_traffic` is any exchange, keep-alives included: the keep-alive
schedule measures it. If keep-alives counted as use, the line would never
go idle.
Invariant -- which errors keep the line. An operation raises a
`DeviceError` only for a verdict reached over a healthy link: the event is
not there, the id is stale, the record cannot be named. `_exchange` keeps
the line for those. Anything the library raises means the link is
suspect, and `_exchange` hangs up. `DecodeMismatch` is a library error,
so it hangs up too -- conservative, since the link may be fine. Operations
added in later phases must keep to this: never wrap a link failure in a
`DeviceError` inside an op, or the line stays open on a broken link.
The exceptions: `CallHomeInProgress` and `WrongUnit` release the line,
because the line itself is the problem; so does `ChangeUnconfirmed`, which
the change core raises only after a link fault or a ring, once the frame
has gone out. `AuditIncomplete` keeps the line unless its `release_line`
says the path would have hung up anyway (a ring, a link fault, a refusal).
"""
def __init__(self, address: UnitAddress, serial: str,
client_factory: Callable[[UnitAddress], Any],
clock: Callable[[], float] = time.monotonic) -> None:
self.address = address
self.serial = normalise_serial(serial)
self._factory = client_factory
self._clock = clock
self._client: Optional[Any] = None
self.info = None
self.last_used = clock()
self.last_traffic = self.last_used
@property
def is_open(self) -> bool:
client = self._client # one read: held_serial() calls this without the unit lock
return client is not None and client.is_open()
def call_up(self):
client = self._factory(self.address)
try:
client.open()
info = client.connect()
except RingDetected as exc:
_close(client)
log.warning("RADIO RING from %s during call-up -- released the line", self.address.key)
raise CallHomeInProgress(_RING_MESSAGE) from exc
except Exception as exc:
_close(client)
raise translate(exc, connecting=True) from exc
if normalise_serial(info.serial) != self.serial:
_close(client)
raise WrongUnit(f"asked for {self.serial} but {info.serial} answered at {self.address.key}")
self._client, self.info = client, info
self.last_used = self.last_traffic = self._clock()
log.info("call-up: %s at %s, staying on the line", self.serial, self.address.key)
return info
def _exchange(self, op: Callable[[Any], T]) -> T:
try:
return op(self._client)
except RingDetected as exc:
self.hang_up()
log.warning("RADIO RING from %s -- released the line so the call reaches THOR",
self.address.key)
raise CallHomeInProgress(_RING_MESSAGE) from exc
except (CallHomeInProgress, WrongUnit, ChangeUnconfirmed) as exc:
# The line itself is the problem: a call-home rides whatever holds the
# modem's single TCP session, and a line held for X that answers as Y
# must not stay held. ChangeUnconfirmed always follows a link fault
# or a ring (the core converts those itself, so the RingDetected
# clause above never sees them). All three are DeviceErrors, so this
# clause must stay above `except DeviceError`.
self.hang_up()
log.warning("%s at %s -- released the line: %s", type(exc).__name__,
self.address.key, exc)
raise
except AuditIncomplete as exc:
# A finish that failed on a path that hangs up anyway (ring, link
# fault, refusal) must still hang up; on a healthy path, keep the line.
if exc.release_line:
self.hang_up()
log.warning("AuditIncomplete at %s -- released the line: %s",
self.address.key, exc)
raise
except DeviceError:
# The operation's own verdict (event not found, stale id): the line
# is healthy, so keep it. Library errors still hang up below.
raise
except Exception as exc:
self.hang_up()
raise translate(exc, connecting=False) from exc
def run(self, op: Callable[[Any], T]) -> T:
"""A user request. Calls up first if the line is not open."""
if not self.is_open:
self.call_up()
result = self._exchange(op)
self.last_used = self.last_traffic = self._clock()
return result
def keepalive(self) -> None:
"""A POLL so the modem's idle timer does not drop the line. Not use."""
if not self.is_open:
return
self._exchange(lambda c: c.protocol.poll())
self.last_traffic = self._clock()
def listen(self) -> None:
"""Read anything the unit sent unprompted; send nothing. Not use."""
if not self.is_open:
return
self._exchange(lambda c: c.read_unsolicited())
def hang_up(self) -> None:
if self._client is not None:
_close(self._client)
self._client = None
log.info("hang-up: %s at %s", self.serial, self.address.key)
# ── Operations (each runs inside Series4Session.run) ──────────────────────────
def s4_identify(client: Any, serial: str) -> UnitInfo:
info = client.connect()
return UnitInfo(
serial=info.serial, series=4, model=info.model,
firmware=None, # the version string lives in 0x01, undecoded
monitoring=info.monitoring, active_setup=info.active_setup,
detail={"manufacturer": info.manufacturer, "firmware_line": info.firmware_line},
)
def s4_status(client: Any, serial: str, run_state: bool = False) -> UnitStatus:
st = client.get_state()
count = client.get_event_count()
detail = {}
if run_state: # one more round trip, so only when asked (the ring-path bench test)
rs = client.read_run_state()
detail["run_state"] = {"code": rs.code, "name": rs.name}
return UnitStatus(
serial=serial, series=4, monitoring=st.monitoring, battery_volts=st.battery_volts,
memory_total_bytes=st.memory_total_bytes, memory_free_bytes=st.memory_free_bytes,
device_time=st.device_time.isoformat() if st.device_time else None,
event_count=count, detail=detail,
)
def s4_settings(client: Any, serial: str) -> UnitSettings:
s = client.get_setup()
return UnitSettings(
serial=serial, series=4, setup_name=s.name, record_mode=s.record_mode_name,
sample_rate=s.sample_rate, record_time_s=s.record_time_s,
histogram_interval_s=s.histogram_interval_s,
geo_trigger_ips=s.geo_trigger_ips[0], # the keypad writes all three the same
notes=dict(s.notes),
detail={
"pretrigger_s": s.pretrigger_s,
"auto_record_stop": s.auto_record_stop,
"auto_stop_after_s": s.auto_stop_after_s,
"geophones_active": s.geophones_active,
"mic_active": s.mic_active,
"trigger_on_geophones": s.trigger_on_geophones,
"trigger_on_mic": s.trigger_on_mic,
"geo_trigger_ips_per_channel": list(s.geo_trigger_ips),
"mic_type": s.mic_type,
"mic_trigger_psi": s.mic_trigger_psi,
"mic_trigger_db": s.mic_trigger_db,
"job_number_enabled": s.job_number_enabled,
"job_number": s.job_number,
"scaled_distance_enabled": s.scaled_distance_enabled,
"distance_ft": s.distance_ft,
"charge_weight_lb": s.charge_weight_lb,
"scaled_distance": s.scaled_distance,
},
)
def _s4_ref(ref: Any, serial: str) -> EventRef:
peaks = ref.peaks_ips or {}
return EventRef(
event_id=make_event_id(serial, ref.key, stamp_of(ref.timestamp)),
serial=serial, series=4, index=ref.index, timestamp=iso_of(ref.timestamp),
record_type=ref.record_type, peak_vector_sum_ips=ref.peak_vector_sum_ips,
peaks_ips={k.lower(): v for k, v in peaks.items() if k in ("Tran", "Vert", "Long")},
filename=ref.filename,
detail={"size_bytes": ref.size, "mic": peaks.get("Mic"), "setup": ref.setup,
"sensor_location": ref.sensor_location},
)
def s4_list_events(client: Any, serial: str) -> EventList:
return EventList(serial=serial, series=4,
events=[_s4_ref(r, serial) for r in client.list_events(with_records=True)])
def s4_download_event(client: Any, serial: str, key: bytes, stamp: Optional[str]) -> DownloadedEvent:
"""Walk to the event and download it there -- the order THOR uses, the only
one captured. Downloading at a parked cursor has never been tried."""
for ref in client.iter_events(with_records=True):
if ref.key != key:
continue
found = stamp_of(ref.timestamp)
if stamp is not None and found is None:
raise MalformedReply(
f"could not read event {key.hex()}'s record (0C) timestamp to confirm it "
"is the one listed -- not downloaded; try again")
if stamp is not None and found != stamp:
raise StaleEvent(
f"the event at {key.hex()} on {serial} is from {found}, not {stamp} -- "
"the unit was erased or wrapped since the list was read; list again")
if ref.filename is None:
raise MalformedReply(
f"event {key.hex()}: its record gave no type or timestamp, so it cannot be named or stored")
# THOR's chunk size. A 16 KB chunk takes ~7 s on cellular against the
# 10 s receive deadline; 1 KB is what THOR itself sends.
blob, result = client.fetch_event(ref, chunk_size=THOR_CHUNK_SIZE)
err = client.decode_error(ref, result)
return DownloadedEvent(
event_id=make_event_id(serial, key, found), serial=serial, series=4,
filename=ref.filename, verified=True if err is not None else None,
idf_bytes=blob, timestamp=ref.timestamp,
record={"peak_vector_sum_ips": ref.peak_vector_sum_ips,
"sensor_location": ref.sensor_location, "setup": ref.setup},
detail={"size_bytes": ref.size, "pvs_error": err},
)
raise EventNotFound(f"no event {key.hex()} on {serial} -- list the events again")
def s4_change_monitoring(client: Any, serial: str, *, start: bool, dry_run: bool,
even_if_already: bool, audit: Any, address: UnitAddress,
caller: str, sleep: Callable[[float], None],
verify_timeout_s: float, verify_interval_s: float) -> ChangeResult:
"""Series-4 pieces for the shared core in change.py."""
plan = plan_start_monitoring() if start else plan_stop_monitoring()
def send() -> dict:
acks = client.protocol.execute(plan)
return {"subs": [f"0x{a.sub:02X}" for a in acks], "data": [bytes(a.data).hex() for a in acks]}
return run_change(
serial=serial, series=4, start=start, dry_run=dry_run, even_if_already=even_if_already,
audit=audit, address=address, caller=caller, sleep=sleep,
verify_timeout_s=verify_timeout_s, verify_interval_s=verify_interval_s,
read_serial=lambda: client.serial(refresh=True),
read_state=lambda: client.read_run_state().name,
describe_plan=plan.describe, send=send,
is_refusal=lambda e: isinstance(e, OpcodeRefused),
is_ring=lambda e: isinstance(e, RingDetected),
# A RADIO RING already buffered is caught here, before 0x96/0x97 goes
# out. One transport read: RingWatchTransport over Tcp/SerialTransport,
# each with a 10 ms read timeout, so it returns at once on a quiet line.
pre_send=lambda: client.read_unsolicited())
+20
View File
@@ -0,0 +1,20 @@
"""Which series a unit is, from its serial prefix (decided with Brian, 2026-10-20)."""
from __future__ import annotations
from .errors import BadRequest
SERIES_BY_PREFIX = {"UM": 4, "BE": 3, "BA": 3}
def normalise_serial(serial: str) -> str:
return (serial or "").strip().upper()
def series_for_serial(serial: str) -> int:
s = normalise_serial(serial)
for prefix, series in SERIES_BY_PREFIX.items():
if s.startswith(prefix) and len(s) > len(prefix):
return series
raise BadRequest(
f"unknown serial {serial!r}: expected UM... (Series 4) or BE.../BA... (Series 3)"
)
+44 -4
View File
@@ -12,8 +12,11 @@ Layout written to `<filename>.h5`:
├─ samples_int16/ (optional)
│ ├─ Tran (int16, raw ADC counts) shape: (N,)
│ └─ ... per channel (only when present in the source)
├─ sensor_check/ (optional, schema v2+)
│ ├─ Tran (int32, raw counts) shape: (M,) M ≪ N
│ └─ ... per channel present in the source (MicL absent on 3-channel units)
└─ root attrs (event metadata):
schema_version int = 1
schema_version int = 2
kind str = "sfm.event.hdf5"
serial str
waveform_key str (8-hex)
@@ -64,7 +67,7 @@ from minimateplus.models import Event
log = logging.getLogger(__name__)
SCHEMA_VERSION = 1
SCHEMA_VERSION = 2 # v2 adds the optional /sensor_check group
HDF5_KIND = "sfm.event.hdf5"
# Geophone full-scale velocity per range (in/s). Confirmed in CLAUDE.md
@@ -270,6 +273,22 @@ def write_event_hdf5(
)
igrp.attrs["mic_psi_per_count"] = float(mic_factor)
# /sensor_check — optional short diagnostic self-check traces (schema
# v2+). Raw ADC counts (a shape diagnostic; the per-series count scale
# differs, and the renderer fits each trace to its box). Only channels
# the decoder found are written — 3-channel units carry no MicL.
sc = event.sensor_check or {}
if sc:
scgrp = f.create_group("sensor_check")
for ch in ("Tran", "Vert", "Long", "MicL"):
vals = sc.get(ch)
if vals:
scgrp.create_dataset(
ch, data=np.asarray(vals, dtype=np.int32),
compression="gzip", compression_opts=4, shuffle=True,
)
scgrp.attrs["units"] = "raw_counts"
import os
os.replace(tmp, path)
@@ -334,6 +353,16 @@ def read_event_hdf5(path: Union[str, Path]) -> dict:
if mic_attr is not None:
mic_psi = float(mic_attr)
# /sensor_check — optional (schema v2+); absent on older files.
sensor_check = None
scgrp = f.get("sensor_check")
if scgrp is not None:
sensor_check = {}
for ch in ("Tran", "Vert", "Long", "MicL"):
ds = scgrp.get(ch)
if ds is not None:
sensor_check[ch] = np.asarray(ds[()])
return {
"schema_version": sv,
"kind": attrs.get("kind"),
@@ -341,6 +370,7 @@ def read_event_hdf5(path: Union[str, Path]) -> dict:
"samples": samples,
"samples_int16": samples_int16,
"mic_psi_per_count": mic_psi,
"sensor_check": sensor_check,
}
@@ -431,11 +461,16 @@ def plot_json_from_hdf5(
event_id: Optional[str] = None,
index: Optional[int] = None,
) -> dict:
"""Build a `sfm.plot.v1` JSON dict from a stored .h5 file."""
"""Build a `sfm.plot.v1` JSON dict from a stored .h5 file.
The dict also carries a top-level ``sensor_check`` key (the raw self-check
traces as ``{ch: [int]}``, or None) beyond the plot schema, so report
generation can read the traces from the same single .h5 load.
"""
data = read_event_hdf5(path)
a = data["attrs"]
s = data["samples"]
return _build_plot_dict(
out = _build_plot_dict(
n_samples=len(s["Tran"]) if "Tran" in s else 0,
sample_rate=int(a.get("sample_rate", 1024) or 1024),
pretrig_samples=int(a.get("pretrig_samples", 0) or 0),
@@ -463,6 +498,11 @@ def plot_json_from_hdf5(
event_id=event_id,
index=index,
)
scd = data.get("sensor_check")
out["sensor_check"] = (
{ch: v.tolist() for ch, v in scd.items()} if scd else None
)
return out
def _build_plot_dict(
+128
View File
@@ -0,0 +1,128 @@
"""Store an event SFM downloaded from a unit -- the SDM side of
POST /device/events/download.
Both series end in the two writes every other ingest path makes: the waveform
store (file + sidecar + .h5) and SeismoDb.insert_events().
An event already stored -- by an earlier download, or by THOR's watcher or
Blastware's ACH -- is returned as it is and NOTHING is written. The watcher's
copy is the richer one (its paired report carries PVS, project strings and ZC
frequencies a bare download does not), so a download never merges into it or
replaces it.
"""
from __future__ import annotations
import datetime
from pathlib import Path
from typing import Any, Optional
from sfm.device_access.models import DownloadedEvent, EventDownload
class IngestError(Exception):
"""Downloaded from the unit, but could not be stored."""
def backfill_series3_event(ev: Any, cc: Any) -> None:
"""Compliance-config values that supersede what the 5A stream decoded.
Some STRT fields have ambiguous semantics (STRT[20] is rectime, but
STRT[8:10] / STRT[16:18] are device-specific scratch, not reliable sample or
pre-trigger counts). Shared with GET /device/event/{i}/blastware_file.
"""
if not cc:
return
if ev.sample_rate is None and cc.sample_rate:
ev.sample_rate = cc.sample_rate
if cc.record_time:
# Authoritative: the user-set value the unit followed when recording.
ev.rectime_seconds = cc.record_time
# Derive total_samples from sample_rate x rectime when we can; the
# STRT-derived value can land at a buffer offset rather than a count.
if ev.sample_rate and ev.rectime_seconds:
derived = int(round(ev.sample_rate * ev.rectime_seconds))
if (ev.total_samples is None
or ev.total_samples > derived * 2
or ev.total_samples < derived // 4):
ev.total_samples = derived
def _event_dt(ev: Any) -> Optional[datetime.datetime]:
ts = getattr(ev, "timestamp", None)
try:
return datetime.datetime(ts.year, ts.month, ts.day, ts.hour, ts.minute, ts.second)
except Exception: # noqa: BLE001
return None
def _already_stored(dl: DownloadedEvent, row: dict) -> EventDownload:
return EventDownload(
event_id=dl.event_id, serial=dl.serial, series=dl.series, db_event_id=row["id"],
stored_filename=row.get("blastware_filename") or "",
filesize=row.get("blastware_filesize"),
sha256=None, # the events table does not keep one
inserted=False, verified=dl.verified,
detail={**dl.detail, "already_stored": True},
)
def _overlay_s4_record(ev: Any, record: dict) -> None:
"""Fill, where the file left them empty, what the unit's 0x0C said.
Without Thor's TXT report the IDF file gives only the three PPVs. The
vector sum matters beyond display: find_twins matches on it. Not the mic:
its 0x0C decode reads a denormal (parked).
"""
from minimateplus.models import PeakValues, ProjectInfo
pvs = record.get("peak_vector_sum_ips")
if pvs is not None:
if ev.peak_values is None:
ev.peak_values = PeakValues()
if ev.peak_values.peak_vector_sum is None:
ev.peak_values.peak_vector_sum = pvs
location = record.get("sensor_location")
if location is not None:
if ev.project_info is None:
ev.project_info = ProjectInfo()
if ev.project_info.sensor_location is None:
ev.project_info.sensor_location = location
def persist_download(dl: DownloadedEvent, *, store: Any, db: Any) -> EventDownload:
# Never merge: a row for (serial, timestamp) means the event is stored, and
# whoever stored it first keeps it. No store call, no insert, no sidecar.
if dl.timestamp is not None:
rows = db.query_events(serial=dl.serial, from_dt=dl.timestamp, to_dt=dl.timestamp, limit=1)
if rows:
return _already_stored(dl, rows[0])
if dl.series == 4:
ev, rec = store.save_imported_idf(dl.idf_bytes, source_path=Path(dl.filename),
serial_hint=dl.serial)
if ev is not None:
_overlay_s4_record(ev, dl.record)
family = "series4"
else:
ev = dl.event
if ev is None:
raise IngestError(f"{dl.filename}: the download carried no event; nothing was stored")
backfill_series3_event(ev, dl.compliance)
geo_range = getattr(dl.compliance, "geo_range", None) if dl.compliance else None
rec = store.save(ev, serial=dl.serial, a5_frames=dl.a5_frames,
geo_range=geo_range if geo_range is not None else "normal")
family = "series3"
if ev is None or ev._waveform_key is None:
raise IngestError(f"{dl.filename}: stored the file but could not build a database row")
inserted, _skipped = db.insert_events(
[ev], serial=dl.serial,
waveform_records={ev._waveform_key.hex(): rec}, device_family=family)
row_id = None
dt = _event_dt(ev)
if dt is not None:
rows = db.query_events(serial=dl.serial, from_dt=dt, to_dt=dt, limit=1)
row_id = rows[0]["id"] if rows else None
return EventDownload(
event_id=dl.event_id, serial=dl.serial, series=dl.series, db_event_id=row_id,
stored_filename=rec["filename"], filesize=rec["filesize"], sha256=rec.get("sha256"),
inserted=inserted > 0, verified=dl.verified, detail=dict(dl.detail),
)
+181 -45
View File
@@ -121,6 +121,13 @@ class ReportData:
t0_ms: Optional[float] = None
dt_ms: Optional[float] = None
# Sensor self-check traces — {ch: [samples]} in raw counts, read from the
# standardized .h5 (/sensor_check group, schema v2+) where the per-series
# decoder stored them at ingest. The little diagnostic waveforms BW draws
# in its "Sensor Check" strip. Empty when absent (pre-v2 .h5, histogram,
# or 3-channel unit's MicL).
sensor_check_waveforms: dict = field(default_factory=dict)
# Record-type discriminator
record_type: Optional[str] = None
is_histogram: bool = False
@@ -246,6 +253,8 @@ def gather_report_data(
"peak_accel_g": ch.get("peak_accel_g"),
"peak_disp_in": ch.get("peak_disp_in"),
"sensor_check": sc_ch.get("result"),
"sc_freq_hz": sc_ch.get("freq_hz"),
"sc_ratio": sc_ch.get("ratio"),
"peak_date": peak_date,
"peak_time": peak_time,
})
@@ -287,6 +296,12 @@ def gather_report_data(
rd.pretrig_samples = ta.get("pretrig_samples")
rd.t0_ms = ta.get("t0_ms")
rd.dt_ms = ta.get("dt_ms")
# Sensor self-check traces — read from the standardized .h5 (schema
# v2+). Device-agnostic: whichever decoder produced the event
# stored them at ingest, so SFM reads them here without knowing or
# caring about the source instrument series. Empty on pre-v2 files
# (until backfilled) and on 3-channel / histogram events.
rd.sensor_check_waveforms = wf.get("sensor_check") or {}
except Exception as exc:
log.warning("gather_report_data: hdf5 read failed: %s", exc)
@@ -396,9 +411,34 @@ def _render_waveform_layout(fig, rd: ReportData) -> None:
ax_stats = fig.add_subplot(gs[2]); ax_stats.axis("off")
_draw_channel_stats_waveform(ax_stats, rd)
_draw_compliance_panel(fig, rd)
_draw_waveform_subplot(fig, gs[3], rd)
# Compliance-chart placement, in figure fractions. Measured directly off a
# Blastware Event Report PDF (ref-stuff/n844lqhbzt0w_bw_pdf.pdf) so the chart
# matches BW's size and position: it spans from just under the header down
# through the stats band, hard against the right page margin. The left edge
# leaves room for the y-axis tick labels + "Velocity (in/s)" title, which the
# compacted stats table (see _draw_channel_stats_waveform) is sized to clear.
_COMPLIANCE_BOX = (0.489, 0.502, 0.951, 0.867) # x0, y0, x1, y1
def _draw_compliance_panel(fig, rd: ReportData) -> None:
"""Large USBM RI8507 compliance chart in the upper-right, sized and
positioned to match Blastware's Event Report (see _COMPLIANCE_BOX)."""
x0, y0, x1, y1 = _COMPLIANCE_BOX
fig.text((x0 + x1) / 2, y1 + 0.006, "USBM RI8507 And OSMRE", fontsize=9,
weight="bold", color="#333", ha="center", va="bottom")
if rd.channels and rd.sample_rate_sps:
from sfm.compliance import draw_compliance_chart
ax = fig.add_axes([x0, y0, x1 - x0, y1 - y0])
draw_compliance_chart(ax, rd.channels, rd.sample_rate_sps)
else:
fig.text((x0 + x1) / 2, (y0 + y1) / 2, "(no waveform data)", fontsize=8,
color="#bbb", ha="center", va="center", style="italic")
def _render_histogram_layout(fig, rd: ReportData) -> None:
"""Histogram layout: header / mic-only / per-channel stats / bar plot.
@@ -477,11 +517,11 @@ def _split_iso_to_date_time(iso: Optional[str]) -> tuple[Optional[str], Optional
return (None, None)
def _kv(ax, x, y, label, value, *, label_w=0.18):
def _kv(ax, x, y, label, value, *, label_w=0.18, fontsize=8):
"""Render a 'Label Value' row at axes-coordinates (x, y)."""
ax.text(x, y, label, fontsize=8, color="#555", ha="left", va="top",
ax.text(x, y, label, fontsize=fontsize, color="#555", ha="left", va="top",
transform=ax.transAxes)
ax.text(x + label_w, y, _fmt(value), fontsize=8, ha="left", va="top",
ax.text(x + label_w, y, _fmt(value), fontsize=fontsize, ha="left", va="top",
transform=ax.transAxes, family="monospace")
@@ -544,14 +584,17 @@ def _draw_header_columns(ax, rows_left, rd: ReportData) -> None:
("File Name", rd.file_name),
("Post Event Notes", rd.post_event_notes),
]
# fontsize 7.5 (BW's header is a touch smaller than our body text) + a
# tighter right-column value indent so the long serial+firmware line
# ("BE##### V ##.##-#.## MiniMate Plus") fits without running off the page.
y = 0.95
dy = 0.095
for label, value in rows_left:
_kv(ax, 0.0, y, label, value, label_w=0.18)
_kv(ax, 0.0, y, label, value, label_w=0.18, fontsize=7.5)
y -= dy
y = 0.95
for label, value in rows_right:
_kv(ax, 0.55, y, label, value, label_w=0.20)
_kv(ax, 0.55, y, label, value, label_w=0.14, fontsize=7.5)
y -= dy
@@ -574,19 +617,14 @@ def _draw_mic_and_usbm(ax, rd: ReportData) -> None:
transform=ax.transAxes, va="top")
rows = _mic_rows(rd)
y = 0.80
# Tighter label indent + slightly smaller font so the long "Channel Test
# Passed (Freq = … Amp = … mv)" line clears the enlarged compliance chart's
# left edge (_COMPLIANCE_BOX) instead of running behind it.
for label, value in rows:
_kv(ax, 0.0, y, label, value, label_w=0.18)
_kv(ax, 0.0, y, label, value, label_w=0.13, fontsize=7)
y -= 0.15
# USBM chart placeholder — upper-right. Real piecewise compliance
# curves are a separate work item; for now this just shows the title
# + a "see report" message so the layout is correct.
ax.text(0.72, 0.97, "USBM RI8507 And OSMRE",
fontsize=9, weight="bold", color="#333", ha="center", va="top",
transform=ax.transAxes)
ax.text(0.72, 0.50, "[compliance chart\ncoming soon]",
fontsize=8, color="#bbb", ha="center", va="center",
transform=ax.transAxes, style="italic")
# The USBM compliance chart is drawn as its own large square panel spanning
# the mic + stats rows on the right — see _draw_compliance_panel().
def _mic_rows(rd: ReportData) -> list[tuple[str, Optional[str]]]:
@@ -636,8 +674,18 @@ def _draw_channel_stats_waveform(ax, rd: ReportData) -> None:
("Peak Acceleration", "peak_accel_g", "g"),
("Peak Displacement", "peak_disp_in", "in"),
("Sensor Check", "sensor_check", ""),
# Sensor-check sub-rows (indented under "Sensor Check", like BW): the
# geophone ring-down frequency + overswing ratio from the self-check.
(" Frequency", "sc_freq_hz", "Hz"),
(" Overswing Ratio", "sc_ratio", ""),
]
_draw_stats_table(ax, rd, rows_spec)
# Compacted to the left half so the enlarged compliance chart (BW-sized,
# right against the page margin) has room — see _COMPLIANCE_BOX.
_draw_stats_table(
ax, rd, rows_spec,
bbox_width=0.42, fontsize=7.5,
col_widths=[0.185, 0.065, 0.065, 0.065, 0.040],
)
_draw_pvs_summary(ax, rd, n_data_rows=len(rows_spec))
@@ -698,19 +746,39 @@ def _draw_pvs_summary(
table_bottom_y = getattr(ax, "_stats_table_bottom", -0.10)
pvs_y = table_bottom_y - 0.04 # small gap below the table border
# Centered for visual balance — looks intentional rather than offset.
# The original BW-replica had a "NA: Not Applicable" caption below
# this line; dropped because we use "—" for missing values and the
# legend was always squished against the PVS line.
ax.text(0.5, pvs_y, line, fontsize=9, weight="bold",
ha="center", va="top", transform=ax.transAxes)
# Centered under the stats table for visual balance — looks intentional
# rather than offset. When the table is compacted (waveform layout), it
# occupies only the left portion of the axes, so center on the table's
# width rather than the full axes (which would push the line under the
# compliance chart). The original BW-replica had a "NA: Not Applicable"
# caption below this line; dropped because we use "—" for missing values.
table_w = getattr(ax, "_stats_table_width", 0.80)
if table_w < 0.79:
# Compacted (waveform) layout: left-align under the table, one point
# smaller, so the line clears the enlarged compliance chart's
# bottom-left tick labels on the right.
ax.text(0.0, pvs_y, line, fontsize=8, weight="bold",
ha="left", va="top", transform=ax.transAxes)
else:
ax.text(0.5, pvs_y, line, fontsize=9, weight="bold",
ha="center", va="top", transform=ax.transAxes)
def _draw_stats_table(ax, rd: ReportData, rows_spec: list[tuple[str, str, str]]) -> None:
def _draw_stats_table(
ax, rd: ReportData, rows_spec: list[tuple[str, str, str]],
*, bbox_width: float = 0.80, fontsize: float = 8,
col_widths: Optional[list[float]] = None,
) -> None:
"""Render a per-channel stats table (Tran/Vert/Long).
rows_spec: list of (label, field_name_in_channel_stats, unit_string)
``bbox_width`` / ``col_widths`` / ``fontsize`` let a caller compact the
table (the waveform layout packs it into the left half to clear the
compliance chart; the histogram layout keeps the wider defaults).
"""
if col_widths is None:
col_widths = [0.28, 0.14, 0.14, 0.14, 0.10]
headers = ["", "Tran", "Vert", "Long", ""]
ch_lookup = {c["name"]: c for c in rd.channel_stats}
@@ -726,6 +794,8 @@ def _draw_stats_table(ax, rd: ReportData, rows_spec: list[tuple[str, str, str]])
if field == "zc_freq_hz":
prefix = ">" if ch_rec.get("zc_freq_above_range") else ""
return f"{prefix}{val:.0f}"
if field in ("sc_freq_hz", "sc_ratio"):
return f"{val:.1f}" # BW shows 1 decimal (7.5 Hz, 3.6)
return f"{val:.3f}"
return str(val)
@@ -750,16 +820,17 @@ def _draw_stats_table(ax, rd: ReportData, rows_spec: list[tuple[str, str, str]])
table_bottom = 1.0 - table_height
tbl = ax.table(
cellText=table_data,
colWidths=[0.28, 0.14, 0.14, 0.14, 0.10],
colWidths=col_widths,
cellLoc="left", edges="open",
bbox=[0.0, table_bottom, 0.80, table_height],
bbox=[0.0, table_bottom, bbox_width, table_height],
)
tbl.auto_set_font_size(False)
tbl.set_fontsize(8)
tbl.set_fontsize(fontsize)
for j in range(5):
tbl[(0, j)].set_text_props(weight="bold", color="#555")
# Stash the bottom Y so _draw_pvs_summary can position itself below.
# Stash the bottom Y + width so _draw_pvs_summary can position itself.
ax._stats_table_bottom = table_bottom
ax._stats_table_width = bbox_width
def _channel_axis_color(ch: str) -> str:
@@ -769,27 +840,59 @@ def _channel_axis_color(ch: str) -> str:
def _draw_waveform_subplot(fig, gridspec_cell, rd: ReportData) -> None:
"""4-channel stacked waveform plot — Instantel printout order
(MicL on top, Tran on bottom), shared x-axis in SECONDS, trigger
triangle markers at t=0, '0.0' baseline label on right of each."""
inner = gridspec_cell.subgridspec(4, 1, hspace=0.0)
triangle markers at t=0, '0.0' baseline label on right of each.
When sensor self-check traces are present (rd.sensor_check_waveforms), a
narrow "Sensor Check" strip of per-channel mini-plots is drawn to the right,
aligned to the lanes — matching Blastware's Event Report.
"""
from matplotlib.ticker import MaxNLocator
order = ["MicL", "Long", "Vert", "Tran"]
has_sc = bool(rd.sensor_check_waveforms)
if has_sc:
# main lanes + a narrow sensor-check strip column, flush against the
# main panel (BW shares the border — no gap), with the "0.0" baseline
# labels moved to the right of the strip. Proportions match BW's
# Event Report (main ~0.75 / strip ~0.10 of the panel width).
inner = gridspec_cell.subgridspec(4, 2, width_ratios=[1.0, 0.13],
wspace=0.0, hspace=0.0)
else:
inner = gridspec_cell.subgridspec(4, 1, hspace=0.0)
sr = rd.sample_rate_sps or 1024
# Convert ms-based time axis to seconds for the x-axis
dt_s = (rd.dt_ms or (1000.0 / sr)) / 1000.0
t0_s = (rd.t0_ms if rd.t0_ms is not None else 0.0) / 1000.0
# Shared geo scale across Long/Vert/Tran (matches the event modal + BW's
# single amp/div): all three geo lanes use ONE Y scale = the max |sample|
# across them (padded, floored), so relative amplitudes stay honest instead
# of each lane auto-zooming to its own peak. Mic keeps its own (psi) scale.
GEO_FLOOR_INS = 0.05
_geo_amax = 0.0
for _gch in ("Long", "Vert", "Tran"):
for _x in (rd.channels.get(_gch) or []):
_a = abs(_x)
if _a > _geo_amax:
_geo_amax = _a
geo_shared = max(_geo_amax * 1.10, GEO_FLOOR_INS)
main_axes = []
sc_axes = []
last_idx = len(order) - 1
for i, ch in enumerate(order):
ax = fig.add_subplot(inner[i])
ax = fig.add_subplot(inner[i, 0] if has_sc else inner[i])
main_axes.append(ax)
values = rd.channels.get(ch) or []
times = [t0_s + j * dt_s for j in range(len(values))]
if values:
color = _channel_axis_color(ch)
ax.plot(times, values, color=color, linewidth=0.5)
# Symmetric y-axis for geo; zero-anchored for mic.
# Geo: one shared symmetric scale (honest relative amplitudes).
# Mic: symmetric on its own psi scale (different unit).
if ch != "MicL":
amax = max((abs(v) for v in values), default=0.001)
ax.set_ylim(-amax * 1.10, amax * 1.10)
ax.set_ylim(-geo_shared, geo_shared)
else:
amax = max((abs(v) for v in values), default=0.001)
ax.set_ylim(-amax * 1.10, amax * 1.10)
@@ -797,9 +900,12 @@ def _draw_waveform_subplot(fig, gridspec_cell, rd: ReportData) -> None:
# Channel label on the LEFT (matches BW)
ax.set_ylabel(ch, fontsize=8, rotation=0, ha="right", va="center",
color=_channel_axis_color(ch), weight="bold", labelpad=14)
# "0.0" on the RIGHT (BW convention)
ax.text(1.005, 0.5, "0.0", transform=ax.transAxes,
fontsize=7, color="#555", va="center", ha="left")
# "0.0" baseline label on the RIGHT (BW convention). With the sensor-
# check strip attached, it goes to the right of the STRIP (drawn below);
# otherwise just outside the main lane.
if not has_sc:
ax.text(1.005, 0.5, "0.0", transform=ax.transAxes,
fontsize=7, color="#555", va="center", ha="left")
ax.grid(True, linestyle="--", linewidth=0.3, color="#bbb", alpha=0.6)
# Vertical dashed trigger line at t=0
@@ -814,23 +920,53 @@ def _draw_waveform_subplot(fig, gridspec_cell, rd: ReportData) -> None:
else:
ax.tick_params(axis="x", labelsize=7)
ax.tick_params(axis="y", labelsize=6)
# Stacked lanes touch, so the top/bottom y-tick labels of adjacent lanes
# would overprint at the shared boundary. Prune the extreme ticks so
# each boundary shows clean interior ticks (0.5 / 0.0 / -0.5) only.
ax.yaxis.set_major_locator(MaxNLocator(nbins=4, prune="both"))
# Sensor self-check mini-plot in the right strip (aligned to this lane).
if has_sc:
scx = fig.add_subplot(inner[i, 1])
sc_axes.append(scx)
sc_vals = rd.sensor_check_waveforms.get(ch) or []
if sc_vals:
_col = _channel_axis_color(ch)
# Faint zero baseline (BW draws the channel baseline through the
# strip) — reference for the one-sided geophone ring-downs.
scx.axhline(0.0, color=_col, linewidth=0.3, alpha=0.4)
scx.plot(range(len(sc_vals)), sc_vals, color=_col, linewidth=0.5)
# Fit the trace to the box (BW-style) rather than a symmetric
# scale: the geo self-checks are one-sided dips, so a symmetric
# scale would strand them in the bottom half with an empty top.
_lo, _hi = min(sc_vals), max(sc_vals)
_pad = 0.10 * ((_hi - _lo) or 1.0)
scx.set_ylim(_lo - _pad, _hi + _pad)
scx.set_xticks([]); scx.set_yticks([])
for _s in scx.spines.values():
_s.set_linewidth(0.4); _s.set_color("#999")
# "0.0" baseline label to the RIGHT of the strip (BW convention)
scx.text(1.10, 0.5, "0.0", transform=scx.transAxes,
fontsize=7, color="#555", va="center", ha="left")
# Trigger triangle marker ▼ above the top channel at t=0
top_ax = fig.axes[-4] # MicL is the first added in this gridspec
top_ax = main_axes[0] # MicL
top_ax.plot([0], [top_ax.get_ylim()[1]], marker="v", color="black",
markersize=8, clip_on=False, zorder=10)
# "Sensor Check" caption under the strip (BW convention)
if has_sc and sc_axes:
pos = sc_axes[-1].get_position()
fig.text((pos.x0 + pos.x1) / 2, pos.y0 - 0.012, "Sensor Check",
fontsize=7, color="#555", ha="center", va="top")
# Compute scale-per-division for the footer (10 divs across the chart)
# and find peak geo amplitude for the geo amp/div setting.
total_s = times[-1] - times[0] if values else 0
div_s = total_s / 10 if total_s > 0 else 0
geo_amp_div = "—"
for ch in ("Tran", "Vert", "Long"):
v = rd.channels.get(ch) or []
if v:
amax = max(abs(x) for x in v)
geo_amp_div = f"{(amax * 1.1 * 2) / 10:.3f}"
break
# Footer div value reflects the SHARED geo scale (so it's correct for all
# three lanes, not just whichever one happened to be checked first).
geo_amp_div = f"{(geo_shared * 2) / 10:.3f}" if _geo_amax > 0 else "—"
fig.text(
0.11, 0.030,
f"Time(Seconds) {div_s:.2f} sec/div Amplitude Geo: {geo_amp_div} in/s/div Mic: 0.001 psi(L)/div",
+342 -35
View File
@@ -13,6 +13,14 @@ GET /device/info POLL + serial number + full config read
GET /device/events Download all stored events (headers + peak values)
POST /device/connect Explicit connect/identify (same as /device/info)
GET /device/event/{idx} Single event by index (header + waveform record)
GET /device/settings Recording settings (requires serial)
POST /device/hangup Hang up a held Series-4 line
`serial` on /device/info, /device/connect, /device/monitor/status and
/device/settings names the unit (UM... = Series 4, BE.../BA... = Series 3) and
returns the shared model. Without it, the legacy Series-3 behaviour is
unchanged. Series-4 lines are held open between requests and hung up after
5 idle minutes, on POST /device/hangup, or the moment the unit calls home.
Transport query params (supply one set):
Serial (direct RS-232 cable):
@@ -42,7 +50,7 @@ import tempfile
import threading
import time
from pathlib import Path
from typing import Optional
from typing import Mapping, Optional
# FastAPI / Pydantic
try:
@@ -74,6 +82,12 @@ from sfm.database import SeismoDb
from sfm.live_cache import LiveCache as _LiveCache
from sfm.waveform_store import WaveformStore
from sfm import db_snapshot
from sfm.event_ingest import backfill_series3_event, persist_download
import dataclasses
from sfm.device_access import DeviceAccess, DeviceError, UnitAddress
from sfm.device_access.errors import BadRequest
from sfm.device_access.series import normalise_serial, series_for_serial
from sfm.audit import DbAudit
logging.basicConfig(
level=logging.INFO,
@@ -340,6 +354,119 @@ def _run_with_retry(fn, *, is_tcp: bool):
return fn() # let any second failure propagate normally
# ── Device access (serial-named requests) ─────────────────────────────────────
# A request that names the unit by `serial` goes through sfm.device_access:
# same contract for Series 3 and 4. Without `serial`, handlers run their
# legacy Series-3 path unchanged (spec 2026-10-20).
# Constructing it does no I/O and starts no thread until a Series-4 session exists.
# The audit sink is mandatory for live changes: without one they are refused.
_device_access_instance: DeviceAccess = DeviceAccess(audit=DbAudit(_get_db))
def _device_access() -> DeviceAccess:
return _device_access_instance
def _unit_address(port: Optional[str], baud: Optional[int], host: Optional[str],
tcp_port: int) -> UnitAddress:
return UnitAddress(host=host, tcp_port=tcp_port if host else None,
port=None if host else port, baud=baud)
def _via_device_access(fn) -> dict:
try:
result = fn()
except DeviceError as exc:
raise HTTPException(status_code=exc.http_status, detail=str(exc)) from exc
return dataclasses.asdict(result) if dataclasses.is_dataclass(result) else result
def _change_response(fn) -> JSONResponse:
"""Run a start/stop; the ChangeResult is the body, its outcome picks the status.
DeviceError mapping is _via_device_access's -- not repeated here.
"""
body = _via_device_access(fn)
# An allow-list: only a dry run, a skip, or a change read back as made is a 200.
ok = (body["outcome"] in ("dry_run", "skipped")
or (body["outcome"] == "sent" and body["verified"] == "ok"))
status = 200 if ok else (409 if body["verified"] == "mismatch" else 502)
return JSONResponse(status_code=status, content=body)
_SERIAL_AWARE_PATHS = frozenset({
"/device/info", "/device/connect", "/device/monitor/status", "/device/settings",
"/device/events", "/device/events/download",
"/device/monitor/start", "/device/monitor/stop",
})
def _device_guard(path: str, query: Mapping[str, str]) -> Optional[tuple]:
"""Refuse a /device/* request that would reach the wrong series' code.
FastAPI drops query params a route does not declare, so `?serial=UM...` on
a Series-3 route would silently run Series-3 bytes against a Micromate
(0xA2 is CONFIRM ERASE there). Returns (status, detail) to refuse, or None.
/device/hangup is always allowed: it must always be able to release a line.
"""
if not path.startswith("/device/") or path == "/device/hangup":
return None
serial = normalise_serial(query.get("serial") or "")
if serial and path in _SERIAL_AWARE_PATHS:
return None # DeviceAccess routes by series and checks held lines itself
if serial.startswith("UM"):
return 501, f"not supported for Series 4 yet: {path}"
# Everything else runs the legacy Series-3 handler -- whatever serial it
# carried, FastAPI drops it -- so it must not reach a held Series-4 line.
if not (query.get("host") or query.get("port")):
return None
try:
tcp_port = int(query.get("tcp_port") or DEFAULT_TCP_PORT)
# baud is not part of the address key, so it is not parsed here.
addr = _unit_address(query.get("port") or None, None, query.get("host") or None, tcp_port)
except (BadRequest, ValueError):
return None
held = _device_access().held_serial(addr)
if held is not None:
return 409, (f"a Series-4 line to {held} is held at {addr.key}; "
"POST /device/hangup first")
return None
@app.middleware("http")
async def _device_guard_middleware(request, call_next):
refusal = _device_guard(request.url.path, request.query_params)
if refusal is not None:
return JSONResponse(status_code=refusal[0], content={"detail": refusal[1]})
return await call_next(request)
_SERIAL_DOC = "Unit serial -- UM... (Series 4) or BE.../BA... (Series 3). Returns the shared model."
_SERIAL_CHECK_DOC = ("Expected unit serial (BE.../BA...). The unit's own serial is read before "
"any write; a different unit, or one that is not Series 3, is refused (409).")
def _require_series3(unit_serial: Optional[str], expected: Optional[str]) -> None:
"""Refuse (409) a legacy Series-3 write or erase unless the unit at the address
answers as Series 3 -- and as `expected`, when one was named.
0xA2 is CONFIRM ERASE on a MiniMate and ends a call-home on a Micromate, and
these routes had no identity check (phase 1c, 2026-10-29). The serial comes
from connect() where a route already makes it, else one SUB 0x15 read.
"""
try:
series = series_for_serial(unit_serial or "")
except BadRequest:
series = None
if series != 3:
raise HTTPException(status_code=409, detail=(
f"the unit at this address answers as {unit_serial!r}, not a Series-3 unit -- nothing sent"))
if expected and normalise_serial(expected) != normalise_serial(unit_serial):
raise HTTPException(status_code=409, detail=(
f"the unit at this address is {unit_serial}, not {expected} -- nothing sent"))
# ── Helpers ────────────────────────────────────────────────────────────────────
def _backfill_events(events: list, info: "DeviceInfo") -> None:
@@ -404,10 +531,11 @@ def event_browser():
@app.get("/device/info")
def device_info(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5, /dev/ttyUSB0)"),
baud: int = Query(38400, description="Serial baud rate (default 38400)"),
baud: Optional[int] = Query(None, description="Serial baud (default 38400; 115200 for a Micromate)"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay (e.g. 203.0.113.5)"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
force: bool = Query(False, description="Bypass cache and re-read from device"),
serial: Optional[str] = Query(None, description=_SERIAL_DOC),
) -> dict:
"""
Connect to the device, perform the POLL startup handshake, and return
@@ -421,6 +549,10 @@ def device_info(
and re-read directly from the device (e.g. after a config push).
The cache is also automatically invalidated after POST /device/config.
"""
if serial:
return _via_device_access(
lambda: _device_access().identify(_unit_address(port, baud, host, tcp_port), serial))
baud = 38400 if baud is None else baud
log.info("GET /device/info port=%s host=%s tcp_port=%d force=%s", port, host, tcp_port, force)
cache = get_cache()
@@ -459,27 +591,39 @@ def device_info(
@app.post("/device/connect")
def device_connect(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: int = Query(38400, description="Serial baud rate"),
baud: Optional[int] = Query(None, description="Serial baud (default 38400; 115200 for a Micromate)"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
serial: Optional[str] = Query(None, description=_SERIAL_DOC),
) -> dict:
"""
Connect to the device and return identity. POST variant for terra-view
compatibility with the SLMM proxy pattern.
"""
return device_info(port=port, baud=baud, host=host, tcp_port=tcp_port)
# force=True PRESERVES today's behaviour: the old call omitted `force`, so it
# received FastAPI's Query(False) object, which is truthy -- /device/connect
# has always bypassed the cache. Passing False here would quietly change that.
return device_info(port=port, baud=baud, host=host, tcp_port=tcp_port,
force=True, serial=serial)
@app.get("/device/events")
def device_events(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: int = Query(38400, description="Serial baud rate"),
baud: Optional[int] = Query(None, description="Serial baud (default 38400; 115200 for a Micromate)"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
debug: bool = Query(False, description="Include raw record hex for field-layout inspection"),
force: bool = Query(False, description="Bypass cache and re-download all events from device"),
serial: Optional[str] = Query(None, description=_SERIAL_DOC),
) -> dict:
"""
**With `serial`** (UM... or BE.../BA...): the unit's events in the shared
shape for either series, read from headers only -- no event is downloaded
to list it -- and not cached. Each carries an `event_id` for
POST /device/events/download. Without `serial`, the legacy Series-3
behaviour below.
Connect to the device, read the event index, and download all stored
events (event headers + full waveform records with peak values).
@@ -502,6 +646,10 @@ def device_events(
If new events exist on the device, only the new ones are downloaded and merged.
Pass *force=true* to bypass the cache entirely and re-download everything.
"""
if serial:
return _via_device_access(
lambda: _device_access().list_events(_unit_address(port, baud, host, tcp_port), serial))
baud = 38400 if baud is None else baud
log.info("GET /device/events port=%s host=%s debug=%s force=%s", port, host, debug, force)
cache = get_cache()
@@ -903,28 +1051,7 @@ def device_event_blastware_file(
if serial != "UNKNOWN" and ev._waveform_key is not None:
try:
cc = info.compliance_config
# Backfill authoritative compliance-config values onto the
# Event before persisting. These supersede whatever
# _decode_a5_waveform read from the STRT bytes (some of which
# have ambiguous semantics — e.g. STRT[20] is rectime but
# STRT[8:10] / STRT[16:18] are device-specific scratch fields
# that aren't reliable sample/pretrig counts).
if cc:
if ev.sample_rate is None and cc.sample_rate:
ev.sample_rate = cc.sample_rate
if cc.record_time:
# record_time from compliance is authoritative — the
# user-set value the device followed when recording.
ev.rectime_seconds = cc.record_time
# Derive total_samples from sample_rate × rectime when
# we can; the STRT-derived value can land at a buffer-
# offset rather than a sample count.
if ev.sample_rate and ev.rectime_seconds:
derived = int(round(ev.sample_rate * ev.rectime_seconds))
if (ev.total_samples is None
or ev.total_samples > derived * 2
or ev.total_samples < derived // 4):
ev.total_samples = derived
backfill_series3_event(ev, cc)
geo_range = getattr(cc, "geo_range", None) if cc else None
rec = _get_store().save(
ev, serial=serial, a5_frames=a5_frames,
@@ -1006,6 +1133,7 @@ def device_config(
baud: int = Query(38400, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
serial: Optional[str] = Query(None, description=_SERIAL_CHECK_DOC),
) -> dict:
"""
Read the current device config, apply any supplied changes to the compliance
@@ -1044,7 +1172,8 @@ def device_config(
try:
def _do():
with _build_client(port, baud, host, tcp_port) as client:
client.connect()
info = client.connect()
_require_series3(info.serial, serial)
client.apply_config(
recording_mode=body.recording_mode,
sample_rate=body.sample_rate,
@@ -1089,9 +1218,10 @@ def device_config_project(
baud: int = Query(38400, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
serial: Optional[str] = Query(None, description=_SERIAL_CHECK_DOC),
) -> dict:
"""Deprecated alias for POST /device/config — use that instead."""
return device_config(body=body, port=port, baud=baud, host=host, tcp_port=tcp_port)
return device_config(body=body, port=port, baud=baud, host=host, tcp_port=tcp_port, serial=serial)
# ── Monitoring endpoints ───────────────────────────────────────────────────────
@@ -1099,10 +1229,13 @@ def device_config_project(
@app.get("/device/monitor/status")
def device_monitor_status(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: int = Query(38400, description="Serial baud rate"),
baud: Optional[int] = Query(None, description="Serial baud (default 38400; 115200 for a Micromate)"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
force: bool = Query(False, description="Bypass cache and re-read from device"),
serial: Optional[str] = Query(None, description=_SERIAL_DOC),
run_state: bool = Query(False, description="With a UM serial: also read SUB 0x49 "
"(one more round trip) and return its raw code in detail.run_state"),
) -> dict:
"""
Read monitoring status from the device.
@@ -1118,6 +1251,11 @@ def device_monitor_status(
**Caching**: status is cached for 30 seconds to reduce cellular polling overhead.
Pass *force=true* to bypass the cache for an immediate fresh read.
"""
if serial:
return _via_device_access(
lambda: _device_access().status(_unit_address(port, baud, host, tcp_port), serial,
run_state=run_state))
baud = 38400 if baud is None else baud
cache = get_cache()
conn_key = SFMCache.make_conn_key(host, tcp_port, port, baud)
@@ -1160,6 +1298,64 @@ def device_monitor_status(
return result
@app.get("/device/settings")
def device_settings(
serial: str = Query(..., description=_SERIAL_DOC),
port: Optional[str] = Query(None, description="Serial port (e.g. /dev/ttyACM0)"),
baud: Optional[int] = Query(None, description="Serial baud (default by series)"),
host: Optional[str] = Query(None, description="TCP host -- modem IP"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
) -> dict:
"""The unit's recording settings, in the shared shape for either series."""
return _via_device_access(
lambda: _device_access().settings(_unit_address(port, baud, host, tcp_port), serial))
@app.post("/device/events/download")
def device_events_download(
serial: str = Query(..., description=_SERIAL_DOC),
event_id: str = Query(..., description="From GET /device/events?serial=..."),
port: Optional[str] = Query(None, description="Serial port (e.g. /dev/ttyACM0)"),
baud: Optional[int] = Query(None, description="Serial baud (default by series)"),
host: Optional[str] = Query(None, description="TCP host -- modem IP"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
) -> dict:
"""Download one event, check it, and store it in SFM's database.
Read-only on the unit. The stored file and waveform are then at
/db/events/{db_event_id}/... . An event already stored -- by an earlier
download, or by THOR's watcher -- comes back as its existing row and
nothing is written (`inserted: false`, `detail.already_stored: true`).
The unit is busy for the whole download: other requests for it wait,
then get 423.
"""
try:
dl = _device_access().download_event(_unit_address(port, baud, host, tcp_port), serial, event_id)
except DeviceError as exc:
raise HTTPException(status_code=exc.http_status, detail=str(exc)) from exc
try:
out = persist_download(dl, store=_get_store(), db=_get_db())
except Exception as exc:
log.error("events/download: %s downloaded but not stored: %s", dl.event_id, exc, exc_info=True)
raise HTTPException(
status_code=500,
detail=f"downloaded {dl.filename} from the unit but could not store it: {exc}") from exc
return dataclasses.asdict(out)
@app.post("/device/hangup")
def device_hangup(
port: Optional[str] = Query(None, description="Serial port"),
baud: Optional[int] = Query(None, description="Serial baud"),
host: Optional[str] = Query(None, description="TCP host -- modem IP"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
) -> dict:
"""Hang up a held line now instead of waiting for the idle timeout.
`hung_up` is false if nothing was being held."""
return _via_device_access(
lambda: {"hung_up": _device_access().hang_up(_unit_address(port, baud, host, tcp_port))})
@app.get("/device/events/storage_range")
def device_events_storage_range(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
@@ -1262,6 +1458,7 @@ def device_events_erase(
baud: int = Query(38400, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
serial: Optional[str] = Query(None, description=_SERIAL_CHECK_DOC),
) -> dict:
"""
Erase ALL stored events from the device memory.
@@ -1281,7 +1478,8 @@ def device_events_erase(
try:
def _do():
with _build_client(port, baud, host, tcp_port) as client:
client.connect()
info = client.connect()
_require_series3(info.serial, serial)
client.delete_all_events()
_run_with_retry(_do, is_tcp=_is_tcp(host))
except HTTPException:
@@ -1330,6 +1528,7 @@ def device_stop_monitoring_blind(
Returns the number of bytes sent. A 503 means the TCP connect failed
(device busy in another session — caller should retry).
"""
# Not identity-checked (phase 1c): it sends only 0x97/0x96, which mean the same on both series (measured 2026-10-25/27), and it must reach a unit too wedged to answer.
log.info(
"POST /device/stop_monitoring_blind host=%s tcp_port=%s connect_timeout=%.1fs repeat=%d",
host, tcp_port, connect_timeout, repeat,
@@ -1402,6 +1601,7 @@ def device_stop_monitoring_slow_drip(
Compared to spam mode: ~40× fewer bytes/sec on the wire, but each
byte has a much higher chance of actually being parsed.
"""
# Not identity-checked (phase 1c): it sends only 0x97/0x96, which mean the same on both series (measured 2026-10-25/27), and it must reach a unit too wedged to answer.
log.info(
"POST /device/stop_monitoring_slow_drip host=%s tcp_port=%s duration=%.1fs interval=%.2fs connect_timeout=%.1fs",
host, tcp_port, duration_s, interval_s, connect_timeout,
@@ -1531,6 +1731,7 @@ def device_stop_monitoring_spam(
when it finishes. No streaming; if you want live progress, watch
SFM logs.
"""
# Not identity-checked (phase 1c): it sends only 0x97/0x96, which mean the same on both series (measured 2026-10-25/27), and it must reach a unit too wedged to answer.
log.info(
"POST /device/stop_monitoring_spam host=%s tcp_port=%s duration=%.1fs connect_timeout=%.3fs repeat=%d",
host, tcp_port, duration_s, connect_timeout, repeat,
@@ -1602,6 +1803,7 @@ def device_rescue(
recv_timeout: float = Query(5.0, description="Per-frame S3 recv timeout in seconds (default 5)"),
disable_ach: bool = Query(True, description="Disable Auto Call Home on the device before erasing"),
erase: bool = Query(True, description="Erase all stored events after disabling ACH"),
serial: Optional[str] = Query(None, description=_SERIAL_CHECK_DOC),
) -> dict:
"""
Rescue an uncooperative unit by squeezing all maintenance work into a
@@ -1652,6 +1854,11 @@ def device_rescue(
client.poll()
steps.append({"step": "poll", "ok": True, "elapsed_s": round(time.monotonic() - t0, 2)})
if disable_ach or erase:
# One SUB 0x15 read: this route writes call-home and erases.
_require_series3(client.read_serial(), serial)
steps.append({"step": "identify", "ok": True, "elapsed_s": round(time.monotonic() - t0, 2)})
if disable_ach:
client.set_call_home_config(auto_call_home_enabled=False)
steps.append({"step": "disable_ach", "ok": True, "elapsed_s": round(time.monotonic() - t0, 2)})
@@ -1660,6 +1867,8 @@ def device_rescue(
client.delete_all_events()
steps.append({"step": "erase", "ok": True, "elapsed_s": round(time.monotonic() - t0, 2)})
except HTTPException:
raise
except ProtocolError as exc:
steps.append({"step": "error", "ok": False, "detail": f"protocol: {exc}"})
raise HTTPException(status_code=502, detail={"message": f"Protocol error: {exc}", "steps": steps}) from exc
@@ -1686,16 +1895,56 @@ def device_rescue(
@app.post("/device/monitor/start")
def device_monitor_start(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: int = Query(38400, description="Serial baud rate"),
baud: Optional[int] = Query(None, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
) -> dict:
serial: Optional[str] = Query(None, description=_SERIAL_DOC),
dry_run: bool = Query(False, description="Return the planned frames; send nothing"),
even_if_already: bool = Query(False, description="Send even if the unit is already in the target state"),
caller: Optional[str] = Query(None, description="Who is asking (recorded in the audit row)"),
):
"""
Command the device to start monitoring (recording triggered events).
Sends SUB 0x96 and waits for ack SUB 0x69.
With `serial`: the unit's identity is read first (a different unit is a 409,
nothing sent), then its state; `dry_run` returns the planned frames and sends
nothing; a live change is audited (`GET /db/device_commands`), verified by
reading the state back, and never retried. `even_if_already` sends even
when the unit is already in the target state.
Statuses with `serial`:
200 the ChangeResult: a dry run, a skip (already in the state), or a send
read back as made
409 ChangeResult: sent and acknowledged, but the unit never reached the
state (`verified: mismatch`, every state seen kept); or, as an
error, a different unit answered or its state was never measured
(nothing sent either way)
502 ChangeResult: the ack was lost but the unit could be read afterwards
422 a malformed serial or address; 423 the unit is busy;
501 no audit log is configured (nothing sent)
503 the unit is calling home, or a call-home was already waiting before
sending (nothing sent); or the audit log could not be written
(nothing sent)
500 the audit row could not be finished -- the detail says first what
happened to the unit (sent and verified, nothing sent, ...)
504 / 502 / 503 a link failure before anything was sent
A failure AFTER the frame went out (or may have) -- the read-back failed,
the ack was lost and the unit could not be read, or a call-home began --
takes the status its cause would have had (503 for a call-home, 504 for
silence, 502 for a bad reply, 503 for a lost connection), and its detail
says the frame was sent and names the audit record.
Without `serial`: the legacy behaviour above, unchanged.
"""
if serial:
return _change_response(lambda: _device_access().start_monitoring(
_unit_address(port, baud, host, tcp_port), serial, dry_run=dry_run,
even_if_already=even_if_already, caller=caller or "api"))
baud = 38400 if baud is None else baud
conn_key = _live_cache.make_conn_key(host, tcp_port, port, baud)
# Legacy branch, not identity-checked: 0x96/0x97 mean the same on both series (measured).
with _build_client(port=port, baud=baud, host=host, tcp_port=tcp_port) as client:
try:
client.poll()
@@ -1712,16 +1961,56 @@ def device_monitor_start(
@app.post("/device/monitor/stop")
def device_monitor_stop(
port: Optional[str] = Query(None, description="Serial port (e.g. COM5)"),
baud: int = Query(38400, description="Serial baud rate"),
baud: Optional[int] = Query(None, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
) -> dict:
serial: Optional[str] = Query(None, description=_SERIAL_DOC),
dry_run: bool = Query(False, description="Return the planned frames; send nothing"),
even_if_already: bool = Query(False, description="Send even if the unit is already in the target state"),
caller: Optional[str] = Query(None, description="Who is asking (recorded in the audit row)"),
):
"""
Command the device to stop monitoring.
Sends SUB 0x97 and waits for ack SUB 0x68.
With `serial`: the unit's identity is read first (a different unit is a 409,
nothing sent), then its state; `dry_run` returns the planned frames and sends
nothing; a live change is audited (`GET /db/device_commands`), verified by
reading the state back, and never retried. `even_if_already` sends even
when the unit is already in the target state.
Statuses with `serial`:
200 the ChangeResult: a dry run, a skip (already in the state), or a send
read back as made
409 ChangeResult: sent and acknowledged, but the unit never reached the
state (`verified: mismatch`, every state seen kept); or, as an
error, a different unit answered or its state was never measured
(nothing sent either way)
502 ChangeResult: the ack was lost but the unit could be read afterwards
422 a malformed serial or address; 423 the unit is busy;
501 no audit log is configured (nothing sent)
503 the unit is calling home, or a call-home was already waiting before
sending (nothing sent); or the audit log could not be written
(nothing sent)
500 the audit row could not be finished -- the detail says first what
happened to the unit (sent and verified, nothing sent, ...)
504 / 502 / 503 a link failure before anything was sent
A failure AFTER the frame went out (or may have) -- the read-back failed,
the ack was lost and the unit could not be read, or a call-home began --
takes the status its cause would have had (503 for a call-home, 504 for
silence, 502 for a bad reply, 503 for a lost connection), and its detail
says the frame was sent and names the audit record.
Without `serial`: the legacy behaviour above, unchanged.
"""
if serial:
return _change_response(lambda: _device_access().stop_monitoring(
_unit_address(port, baud, host, tcp_port), serial, dry_run=dry_run,
even_if_already=even_if_already, caller=caller or "api"))
baud = 38400 if baud is None else baud
conn_key = _live_cache.make_conn_key(host, tcp_port, port, baud)
# Legacy branch, not identity-checked: 0x96/0x97 mean the same on both series (measured).
with _build_client(port=port, baud=baud, host=host, tcp_port=tcp_port) as client:
try:
client.poll()
@@ -1824,6 +2113,7 @@ def device_call_home_set(
baud: int = Query(38400, description="Serial baud rate"),
host: Optional[str] = Query(None, description="TCP host — modem IP or ACH relay"),
tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"),
serial: Optional[str] = Query(None, description=_SERIAL_CHECK_DOC),
) -> dict:
"""
Read the current call home config, apply supplied changes, and write back.
@@ -1847,6 +2137,7 @@ def device_call_home_set(
def _do():
with _build_client(port, baud, host, tcp_port) as client:
client.poll()
_require_series3(client.read_serial(), serial) # one SUB 0x15 read
client.set_call_home_config(
auto_call_home_enabled=body.auto_call_home_enabled,
after_event_recorded=body.after_event_recorded,
@@ -2928,6 +3219,22 @@ def db_sessions(
return {"count": len(rows), "sessions": rows}
@app.get("/db/device_commands")
def db_device_commands(
serial: Optional[str] = Query(None, description="Filter by unit serial"),
limit: int = Query(100, ge=1, le=1000, description="Max rows to return"),
) -> dict:
"""
The audit trail of changes SFM attempted on units, newest first.
Each row's `sent` says whether a frame went out (1 acknowledged, 0 nothing
sent, null unknown) and `states` holds every state read (before / seen /
after). `serial` is matched case-insensitively.
"""
serial = normalise_serial(serial) if serial else None
return {"commands": _get_db().query_device_commands(serial or None, limit)}
# ── Entry point ────────────────────────────────────────────────────────────────
if __name__ == "__main__":
+756 -82
View File
File diff suppressed because it is too large. Load diff
+18 -2
View File
@@ -595,8 +595,19 @@ class WaveformStore:
)
# Binary-derived peaks fill in when the .txt didn't supply them.
# They're ~3% low vs the device-authoritative .txt values (residual
# codec drift), so .txt always wins when present.
#
# The old justification for this precedence -- "binary peaks are ~3%
# low vs the .txt" -- was a decoder bug (geo LSB 0.0003 instead of
# 0.000310308) and was fixed 2026-09-10; the binary now agrees with
# Thor's own export per-sample. The .txt still wins when present
# because it is what the operator sees in Thor's report.
#
# ⚠ One case where the .txt is the *less* accurate of the two:
# Thor floors displayed histogram PPV at 0.0050 in/s, so on quiet
# IDFH events the .txt reports 0.0050 while the binary decodes the
# true ~0.0025. 41.4% of prod IDFH sidecars carry a component PPV
# larger than their own vector sum because of it. Left as-is
# deliberately, so stored peaks keep matching Thor's report.
if binary_peaks is not None:
if binary_peaks.transverse_ips and not report_dict.get("tran_ppv"):
report_dict["tran_ppv"] = binary_peaks.transverse_ips
@@ -651,6 +662,11 @@ class WaveformStore:
ev.raw_samples = idf_samples
n_samples = max((len(idf_samples.get(ch, [])) for ch in ("Tran", "Vert", "Long", "MicL")), default=0)
ev.total_samples = ev.total_samples or n_samples
# Sensor self-check traces from the IDFW fixed header (waveform
# events only; {} on histograms / when absent). Carried on the
# bridged Event so the .h5 writer persists them like series-3.
from micromate.sensor_check import decode_idf_sensor_check
ev.sensor_check = decode_idf_sensor_check(idf_bytes) or None
# For IDFH histograms there are no per-sample waveform arrays — the
# device stores one peak ADC count per interval per channel. Synthesise
+290
View File
@@ -0,0 +1,290 @@
"""Fakes of both device clients for sfm.device_access tests.
They return the libraries' real dataclasses, and FakeMicromateClient's setup
is decoded from a real UM20147 read. `fail` is a queue of exceptions; each
call pops one, if any, and raises it.
"""
from __future__ import annotations
import copy
import datetime
from pathlib import Path
from micromate.models import MicromateDeviceInfo, MicromateEventRef, MicromateState
from micromate.setup_block import decode_setup
from minimateplus.models import ComplianceConfig, DeviceInfo, Event, MonitorStatus, PeakValues, Timestamp
SETUP_FIXTURE = Path(__file__).parent / "fixtures" / "micromate-setup" / "um20147_baseline.bin"
THOR_IDF = Path(__file__).parent / "fixtures" / "thor-idf"
class _Base:
def __init__(self, fail=None, open_error=None):
self.fail = list(fail or [])
self.open_error = open_error
self.calls: list[str] = []
self.opened = 0
self.closed = 0
self._open = False
def _step(self, name):
self.calls.append(name)
if self.fail:
raise self.fail.pop(0)
def open(self):
self.opened += 1
if self.open_error is not None:
raise self.open_error
self._open = True
def close(self):
self.closed += 1
self._open = False
def s3_event(index, key_hex, when, *, record_type="Waveform", pvs=0.12, frames=True):
ev = Event(index=index)
ev._waveform_key = bytes.fromhex(key_hex)
ev.timestamp = Timestamp(raw=b"", flag=0x10, year=when.year, unknown_byte=0,
month=when.month, day=when.day, hour=when.hour,
minute=when.minute, second=when.second)
ev.record_type = record_type
ev.peak_values = PeakValues(tran=0.05, vert=0.08, long=0.03, micl=0.0001,
peak_vector_sum=pvs)
if frames:
ev._a5_frames = ["frame"]
return ev
def _iso(ev):
"""minimateplus.client._event_timestamp_iso's format; "" with no timestamp."""
ts = ev.timestamp
if ts is None:
return ""
return datetime.datetime(ts.year, ts.month, ts.day, ts.hour or 0, ts.minute or 0,
ts.second or 0).isoformat()
def default_s3_events():
return [
s3_event(0, "01110000", datetime.datetime(2026, 10, 1, 8, 0, 0)),
s3_event(1, "0111245a", datetime.datetime(2026, 10, 2, 9, 30, 15)),
]
class FakeMiniMateClient(_Base):
def __init__(self, serial="BE18193", *, monitoring=False, compliance="default", events=None,
monitor_states=None, write_error=None, **kw):
super().__init__(**kw)
self.serial = serial
self.monitoring = monitoring
self.monitor_states = list(monitor_states) if monitor_states else [monitoring]
self.write_error = write_error
self.writes: list = []
if compliance == "default":
compliance = ComplianceConfig(
recording_mode=0x01, sample_rate=1024, histogram_interval_sec=300,
record_time=3.0, trigger_level_geo=0.5, alarm_level_geo=1.0, geo_range=0,
setup_name="BRIDGE-A", project="Bridge job", client="Acme",
operator="BH", sensor_location="Loc 1", notes=None,
)
self.compliance = compliance
self.events = default_s3_events() if events is None else events
self.download_requests: list = [] # (key4, expected_timestamp) per download
self.last_download = None
def connect(self) -> DeviceInfo:
self._step("connect")
return DeviceInfo(
serial=self.serial, firmware_minor=17, firmware_version="S338.17",
dsp_version="10.72", manufacturer="Instantel", model="MiniMate Plus",
compliance_config=self.compliance,
)
def poll(self) -> None:
self._step("poll")
def wake(self, **kw) -> None:
self._step("wake")
def get_monitor_status(self) -> MonitorStatus:
self._step("get_monitor_status")
state = self.monitor_states.pop(0) if len(self.monitor_states) > 1 else self.monitor_states[0]
# A bool is a measured state; an int (or None: a short section) is the raw 0x1C flag byte.
flag = (0x10 if state else 0x00) if isinstance(state, bool) else state
return MonitorStatus(
is_monitoring=flag == 0x10, battery_v=6.8,
memory_total=983026, memory_free=900000, state_flag=flag,
)
def _write(self, name):
self._step(name)
self.writes.append(name)
if self.write_error is not None:
raise self.write_error
def start_monitoring(self) -> None:
self._write("start_monitoring")
def stop_monitoring(self) -> None:
self._write("stop_monitoring")
def list_event_headers(self):
self._step("list_event_headers")
out = []
for ev in self.events:
h = copy.copy(ev)
h._a5_frames = None
out.append(h)
return out
def download_event_by_key(self, key4, *, expected_timestamp=None):
"""As the real walk: an event whose 0C time is not the expected one comes
back without its 5A."""
self._step("download_event_by_key")
self.download_requests.append((key4, expected_timestamp))
self.last_download = None
for ev in self.events:
if ev._waveform_key == key4:
if expected_timestamp is not None and _iso(ev) != expected_timestamp:
ev = copy.copy(ev)
ev._a5_frames = None
elif ev._a5_frames:
_as_downloaded(ev)
self.last_download = ev
return ev
return None
_REAL = {}
def _as_downloaded(ev):
"""Give a fake event what a real one-event download carries: BE9441 event 1's
recorded A5 frames, their decoded waveform, and the unit's own 0C peaks for it
-- so the download check sees a whole, matching event."""
if not _REAL:
from minimateplus.framing import S3FrameParser
from minimateplus.waveform_codec import decode_a5_frames
raw = (Path(__file__).parent / "fixtures" / "minimate-bench-10-25-26"
/ "BE9441_event1_0111646a_rx.bin").read_bytes()
_REAL["frames"] = [f for f in S3FrameParser().feed(raw) if f.sub == 0xA5]
_REAL["samples"] = decode_a5_frames(_REAL["frames"])
ev._a5_frames = _REAL["frames"]
ev.raw_samples = _REAL["samples"]
pv = ev.peak_values
ev.peak_values = PeakValues(tran=0.030, vert=0.095, long=0.020, micl=pv.micl if pv else None,
peak_vector_sum=pv.peak_vector_sum if pv else None)
def s4_ref(index, key_hex, when, record_type, *, pvs=0.2):
"""Fixture-backed: the filename it produces names a real file in thor-idf/."""
ref = MicromateEventRef(index=index, key=bytes.fromhex(key_hex), size=0, serial="UM20147",
record_type=record_type, timestamp=when, peak_vector_sum_ips=pvs,
peaks_ips={"Tran": 0.1, "Vert": 0.15, "Long": 0.05, "Mic": 0.0002})
ref.size = (THOR_IDF / ref.filename).stat().st_size
return ref
def default_s4_refs():
return [
s4_ref(0, "055d4a81", datetime.datetime(2025, 5, 31, 13, 59, 1), "waveform"),
s4_ref(1, "055d4a83", datetime.datetime(2025, 3, 30, 7, 1, 10), "histogram"),
]
class _FakeProtocol:
def __init__(self, owner):
self._owner = owner
def poll(self):
self._owner._step("poll")
def execute(self, plan):
self._owner._step("execute")
self._owner.executed.append(plan)
if self._owner.execute_error is not None:
raise self._owner.execute_error
return [type("Ack", (), {"sub": s.ack_sub, "data": bytes(11)})() for s in plan.steps]
class FakeMicromateClient(_Base):
def __init__(self, serial="UM20147", *, monitoring=False, events=5,
unsolicited=b"", event_refs=None, run_states=None,
serial_reported=None, execute_error=None, **kw):
super().__init__(**kw)
self.unit_serial = serial # not `serial`: that is the client's method
self.run_states = list(run_states) if run_states else [0x00]
self.serial_reported = serial if serial_reported is None else serial_reported
self.execute_error = execute_error
self.executed = []
self.monitoring = monitoring
self.events = events
self.unsolicited = unsolicited
self.protocol = _FakeProtocol(self)
self.event_refs = default_s4_refs() if event_refs is None else event_refs
self.cursor = None
self.fetched: list = []
def is_open(self) -> bool:
return self._open
def connect(self) -> MicromateDeviceInfo:
self._step("connect")
return MicromateDeviceInfo(
serial=self.unit_serial, manufacturer="Instantel", model="MM/ISEE/S",
firmware_line="thor", monitoring=self.monitoring, active_setup="test2.MMB",
)
def serial(self, *, refresh=False):
self._step("serial")
return self.serial_reported if refresh else self.unit_serial
def read_run_state(self):
from micromate.models import MicromateRunState
self._step("read_run_state")
code = self.run_states.pop(0) if len(self.run_states) > 1 else self.run_states[0]
names = {0x00: "idle", 0x02: "monitoring", 0x03: "calling_home"}
return MicromateRunState(code, names.get(code, f"unknown(0x{code:02X})"))
def get_state(self) -> MicromateState:
self._step("get_state")
return MicromateState(
monitoring=self.monitoring,
device_time=datetime.datetime(2026, 10, 20, 18, 7, 58),
battery_volts=3.8, memory_total_bytes=15_000_000, memory_free_bytes=14_799_296,
)
def get_event_count(self) -> int:
self._step("get_event_count")
return self.events
def get_setup(self):
self._step("get_setup")
return decode_setup(SETUP_FIXTURE.read_bytes()[11:])
def read_unsolicited(self) -> bytes:
self._step("read_unsolicited")
data, self.unsolicited = self.unsolicited, b""
return data
def list_events(self, *, with_records=True):
self._step("list_events")
return list(self.event_refs)
def iter_events(self, *, with_records=True):
self._step("iter_events")
for ref in self.event_refs:
self.cursor = ref.index
yield ref
def fetch_event(self, ref, *, verify=True, tolerance=0.01, chunk_size=None):
self._step("fetch_event")
self.fetched.append((ref.key_hex, chunk_size))
return (THOR_IDF / ref.filename).read_bytes(), object()
@staticmethod
def decode_error(ref, result):
return None if ref.record_type == "histogram" else 0.0
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
@@ -0,0 +1,96 @@
{
"source": "bridges/captures/9-24-26 - micromate2/raw_bw_20260925_011620_ACH-change_1_setting.bin",
"source_sha256": {
"bw": "e44ce87a1e8638a9346386d5182a97ea142c8486fb17b7de2d1c67d1266be9df",
"s3": "5b15f219ff58a64e61c8b2123034dfcc766465534479a61c1447ea6d66ffd878"
},
"unit": "UM12947",
"firmware_version": "11.0CB",
"firmware_line": "blastware",
"exchanges": [
{
"sub": 91,
"request": "41021010005b000030000000000000000000009b03",
"response_sub": 164,
"response_data": "300000000000000000000000000050496e7374616e74656c000600c3f04a00e4194f0074024d4d2f495345452f532f494f00001f603e7657603e76"
},
{
"sub": 21,
"request": "41021010001500000a000000000000000000002f03",
"response_sub": 234,
"response_data": "0a00000000000000000000554d3132393437003100"
},
{
"sub": 73,
"request": "41021010004900ffff000000000000000000005703",
"response_sub": 182,
"response_data": "050000000000000000000000e8000b00"
},
{
"sub": 91,
"request": "41021010005b000030000000000000000000009b03",
"response_sub": 164,
"response_data": "300000000000000000000000000050496e7374616e74656c000600c3f04a00e4194f0074024d4d2f495345452f532f494f00001f603e7657603e76"
},
{
"sub": 44,
"request": "41021010002c00ffff000000000000000000003a03",
"response_sub": 211,
"response_data": "7e00000000000000000000007cdc000004524144494f2052494e470000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000010000000000000000000000000000000000000000000000000000000000034323003c00000000"
},
{
"sub": 126,
"request": "41021010007e00007e00000000000000000000007cdc000005524144494f2052494e47000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000001000000000000000000000000000000000000000000000000000000000010034323003c00000000ce03",
"response_sub": 129,
"response_data": "0000000000000000000000"
},
{
"sub": 127,
"request": "41021010007f00ffff000000000000000000008d03",
"response_sub": 128,
"response_data": "0000000000000000000000"
},
{
"sub": 91,
"request": "41021010005b000030000000000000000000009b03",
"response_sub": 164,
"response_data": "300000000000000000000000000050496e7374616e74656c000600c3f04a00e4194f0074024d4d2f495345452f532f494f00001f603e7657603e76"
},
{
"sub": 21,
"request": "41021010001500000a000000000000000000002f03",
"response_sub": 234,
"response_data": "0a00000000000000000000554d3132393437003100"
},
{
"sub": 73,
"request": "41021010004900ffff000000000000000000005703",
"response_sub": 182,
"response_data": "050000000000000000000000e8000b00"
},
{
"sub": 91,
"request": "41021010005b000030000000000000000000009b03",
"response_sub": 164,
"response_data": "300000000000000000000000000050496e7374616e74656c000600c3f04a00e4194f0074024d4d2f495345452f532f494f00001f603e7657603e76"
},
{
"sub": 44,
"request": "41021010002c00ffff000000000000000000003a03",
"response_sub": 211,
"response_data": "7e00000000000000000000007cdc000005524144494f2052494e470000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000010000000000000000000000000000000000000000000000000000000000032e5e003c00000000"
},
{
"sub": 126,
"request": "41021010007e00007e00000000000000000000007cdc00001004524144494f2052494e47000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000001000000000000000000000000000000000000000000000000000000000010032e5e003c00000000f303",
"response_sub": 129,
"response_data": "0000000000000000000000"
},
{
"sub": 127,
"request": "41021010007f00ffff000000000000000000008d03",
"response_sub": 128,
"response_data": "0000000000000000000000"
}
]
}
+252
View File
@@ -0,0 +1,252 @@
{
"source": "bridges/captures/9-24-26 - micromate2/raw_bw_20260924_191214_turn_on_monitormode_then_attempt_to_write_config.bin",
"source_sha256": {
"bw": "f65dd3b3260eb1fe034169a276e29f631e73fff69c65861d7281718fdbc2d999",
"s3": "dd78a64ac15d1d93492d0db7e3bafceddc1533ad0b6e7f8a5d19bffd83ecce66"
},
"unit": "UM12947",
"firmware_version": "11.0CB",
"firmware_line": "blastware",
"exchanges": [
{
"sub": 91,
"request": "41021010005b000030000000000000000000009b03",
"response_sub": 164,
"response_data": "300000000000000000000000000050496e7374616e74656c000600c3f04a00e4194f0074024d4d2f495345452f532f494f00001f603e7657603e76"
},
{
"sub": 21,
"request": "41021010001500000a000000000000000000002f03",
"response_sub": 234,
"response_data": "0a00000000000000000000554d3132393437003100"
},
{
"sub": 73,
"request": "41021010004900ffff000000000000000000005703",
"response_sub": 182,
"response_data": "050000000000000000000000e8000b00"
},
{
"sub": 91,
"request": "41021010005b000030000000000000000000009b03",
"response_sub": 164,
"response_data": "300000000000000000000000000050496e7374616e74656c000600c3f04a00e4194f0074024d4d2f495345452f532f494f00001f603e7657603e76"
},
{
"sub": 150,
"request": "41021010009600ffff00000000000000000000a403",
"response_sub": 105,
"response_data": "0000000000000000000000"
},
{
"sub": 28,
"request": "41021010001c00ffff000000000000000000002a03",
"response_sub": 227,
"response_data": "2c00000000000000000000000e180907ea20130c19000000000001000000000000000000000000000000000000017c00e4e1c000e3f1c0"
},
{
"sub": 91,
"request": "41021010005b000030000000000000000000009b03",
"response_sub": 164,
"response_data": "300000000000000000000000000050496e7374616e74656c000600c3f04a00e4194f0074024d4d2f495345452f532f494f00001f603e7657603e76"
},
{
"sub": 21,
"request": "41021010001500000a000000000000000000002f03",
"response_sub": 234,
"response_data": "0a00000000000000000000554d3132393437003100"
},
{
"sub": 73,
"request": "41021010004900ffff000000000000000000005703",
"response_sub": 182,
"response_data": "050000000000000000000002e8000b00"
},
{
"sub": 91,
"request": "41021010005b000030000000000000000000009b03",
"response_sub": 164,
"response_data": "300000000000000000000000000050496e7374616e74656c000600c3f04a00e4194f0074024d4d2f495345452f532f494f00001f603e7657603e76"
},
{
"sub": 151,
"request": "41021010009700ffff00000000000000000000a503",
"response_sub": 104,
"response_data": "0000000000000000000000"
},
{
"sub": 28,
"request": "41021010001c00ffff000000000000000000002a03",
"response_sub": 227,
"response_data": "2c000000000000000000000000180907ea64130d22000000000001000000000000000000000000000000000000017c00e4e1c000e3e1c0"
},
{
"sub": 91,
"request": "41021010005b000030000000000000000000009b03",
"response_sub": 164,
"response_data": "300000000000000000000000000050496e7374616e74656c000600c3f04a00e4194f0074024d4d2f495345452f532f494f00001f603e7657603e76"
},
{
"sub": 21,
"request": "41021010001500000a000000000000000000002f03",
"response_sub": 234,
"response_data": "0a00000000000000000000554d3132393437003100"
},
{
"sub": 73,
"request": "41021010004900ffff000000000000000000005703",
"response_sub": 182,
"response_data": "050000000000000000000000e8000b00"
},
{
"sub": 91,
"request": "41021010005b000030000000000000000000009b03",
"response_sub": 164,
"response_data": "300000000000000000000000000050496e7374616e74656c000600c3f04a00e4194f0074024d4d2f495345452f532f494f00001f603e7657603e76"
},
{
"sub": 63,
"request": "41021010003f00ffff000000000000000000004d03",
"response_sub": 192,
"response_data": "ff00000000000000000000666163746f72792e4d4d4200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff00000000000000000000544553542e4d4d4200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff0000000000000000000042555320544553542e4d4d42000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff0000000000000000000057616c7368204a56203234312e6d6d620000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff0000000000000000000057616c7368204a56203030382e6d6d620000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff0000000000000000000048617762616b6572203332322e6d6d620000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff0000000000000000000048617762616b65722033323220626c617374696e672e6d6d620000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff000000000000000000006d696e2e6d6d620000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff00000000000000000000506c6179686f757365204c6f6320312e6d6d620000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff0000000000000000000056616c6c657920526f636b20536f6c7574696f6e2e4d4d42000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff000000000000000000005265636f7264696e6753657475702e6d6d62000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff0000000000000000000055504d432e6d6d6200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff0000000000000000000055504d43204c6f6320332e6d6d6200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff000000000000000000005265736964656e636520496e6e2e6d6d6200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff000000000000000000004d6963726f6d6174652065787420747269676765722e6d6d620000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff000000000000000000004d6963726f6d6174652072656d6f727420616c61726d2e6d6d6200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff0000000000000000000054726565206f66204c696665202d204c6f632031202d203538363120536f6c7761792e6d6d6200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff000000000000000000004d656c652d505753412d436172726f6c6c202d4c6f6320342e6d6d620000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff000000000000000000004d6963726f6d617465206d696e2074726967676572206d6d622e6d6d6200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff00000000000000000000466179202d204c6179746f6e204272696467652050726f6a6563742e6d6d620000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff0000000000000000000044656661756c74204d6963726f6d61746520495345452e6d6d6200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff0000000000000000000054455354312e6d6d62000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 64,
"request": "41021010004000ffff000000000000000000004e03",
"response_sub": 191,
"response_data": "ff00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 65,
"request": "41021010004100ffff000000000000000000004f03",
"response_sub": 190,
"response_data": "ff0000000000000000000054455354312e6d6d62000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
}
]
}
+156
View File
@@ -0,0 +1,156 @@
{
"source": "bridges/captures/9-24-26 - micromate2/raw_bw_20260925_011907_send_multiday_schedule.bin",
"source_sha256": {
"bw": "1884a47bc25ac20f44b5aef4a0f92da6625ce1c809a8794aa2bb5da483ae4bf5",
"s3": "f26370a1bc880dfb08afdf1f3199f9f2811f49bc43ca9d4c9d3dc2b3cabfdbef"
},
"unit": "UM12947",
"firmware_version": "11.0CB",
"firmware_line": "blastware",
"exchanges": [
{
"sub": 91,
"request": "41021010005b000030000000000000000000009b03",
"response_sub": 164,
"response_data": "300000000000000000000000000050496e7374616e74656c000600c3f04a00e4194f0074024d4d2f495345452f532f494f00001f603e7657603e76"
},
{
"sub": 65,
"request": "41021010004100ffff000000000000000000004f03",
"response_sub": 190,
"response_data": "ff0000000000000000000054455354312e6d6d62000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 91,
"request": "41021010005b000030000000000000000000009b03",
"response_sub": 164,
"response_data": "300000000000000000000000000050496e7374616e74656c000600c3f04a00e4194f0074024d4d2f495345452f532f494f00001f603e7657603e76"
},
{
"sub": 65,
"request": "41021010004100ffff000000000000000000004f03",
"response_sub": 190,
"response_data": "ff0000000000000000000054455354312e6d6d62000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 8,
"request": "41021010000800ffff000000000000000000001603",
"response_sub": 247,
"response_data": "5a0000000000000000000000580900000000000000000000000000000000000000000000000000000000000000000000000000000100010001000100000000000000010001000000000000000000000000000000000002000000000000000200000000b42f"
},
{
"sub": 46,
"request": "41021010002e00ffff000000000000000000003c03",
"response_sub": 209,
"response_data": "1c00000000000000000000001ad50000010000000000000000000000000000000000000000141a"
},
{
"sub": 26,
"request": "41021010001a00ffff000000000000000000002803",
"response_sub": 229,
"response_data": "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"
},
{
"sub": 218,
"request": "4102101000da0001000000000000000000000054455354312e6d6d6200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000c603",
"response_sub": 37,
"response_data": "0000000000000000000000"
},
{
"sub": 104,
"request": "41021010006800005a00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000001000100010001000000000000000100010000000000000000000000000000000000100200000000000000100200000000dc03",
"response_sub": 151,
"response_data": "0000000000000000000000"
},
{
"sub": 115,
"request": "41021010007300ffff000000000000000000008103",
"response_sub": 140,
"response_data": "0000000000000000000000"
},
{
"sub": 130,
"request": "41021010008200001c0000000000000000000000000000000100000000000000000000000000000000000000000000af03",
"response_sub": 125,
"response_data": "0000000000000000000000"
},
{
"sub": 131,
"request": "41021010008300ffff000000000000000000009103",
"response_sub": 124,
"response_data": "0000000000000000000000"
},
{
"sub": 113,
"request": "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",
"response_sub": 142,
"response_data": "0000000000000000000000"
},
{
"sub": 114,
"request": "41021010007200ffff000000000000000000008003",
"response_sub": 141,
"response_data": "0000000000000000000000"
},
{
"sub": 91,
"request": "41021010005b000030000000000000000000009b03",
"response_sub": 164,
"response_data": "300000000000000000000000000050496e7374616e74656c000600c3f04a00e4194f0074024d4d2f495345452f532f494f00001f603e7657603e76"
},
{
"sub": 141,
"request": "41021010008d000018000000000000000000005c73797374656d5c7365747570735c74657374322e6d6d626e03",
"response_sub": 114,
"response_data": "0000000000000000000000"
},
{
"sub": 142,
"request": "41021010008e0008900000000000000000000000011004000010020000bf800000000040400000001003000f053e000f00000000000000000001000074657374322e6d6d6200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000004c6f636174696f6e0000000000000000000000000000746573743200000000000000000000000000000000000000000000000000000000000000000000000000436c69656e7400000000000000000000000000000000746573743200000000000000000000000000000000000000000000000000000000000000000000000000436f6d70616e7900000000000000000000000000000074657374320000000000000000000000000000000000000000000000000000000000000000000000000047656e6572616c204e6f746573000000000000000000746573743200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000015472616e00000001004a000a002800151004fb10020d0010030000404698dd00003f000000696e2e003f8000002f732e0000015665727400000001004a000a002800151004fb10020d0010030000404698dd00003f000000696e2e003f8000002f732e0000014c6f6e6700000001004a000a002800151004fb10020d0010030000404698dd00003f000000696e2e003f8000002f732e0000004d696300000000100200c80032000a000a05dc01f4000500003cb8583600003c289d8f707369003ca8b5e4284c290000004c4d6963000000100200c80032000a000a05dc01f4000500003cb8583600003c289d8f707369003ca8b5e4284c29000000534d69630000000900014e4c000a005a0055012c000c00100242920000000042480000644200004270000028412900000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000100010000000100000000000000010001000000000000000000000000000000000000000000000000000000000000000100000000000000000000000000000000000000008d03",
"response_sub": 113,
"response_data": "0000000000000000000000"
},
{
"sub": 91,
"request": "41021010005b000030000000000000000000009b03",
"response_sub": 164,
"response_data": "300000000000000000000000000050496e7374616e74656c000600c3f04a00e4194f0074024d4d2f495345452f532f494f00001f603e7657603e76"
},
{
"sub": 141,
"request": "41021010008d00001d000000000000000000005c73797374656d5c7363686564756c655c7363686564756c652e6461747403",
"response_sub": 114,
"response_data": "0000000000000000000000"
},
{
"sub": 142,
"request": "41021010008e0010040000000000000000000000100400000010100010020954455354312e6d6d620000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000010100110020974657374322e6d6d62000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000001010100210020954455354312e6d6d62000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000001010100310020974657374322e6d6d6200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000008603",
"response_sub": 113,
"response_data": "0000000000000000000000"
},
{
"sub": 142,
"request": "41021010008e001003200000000000000000000000000000000000000000000000000000000000001010100410020954455354312e6d6d620000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000010100510020974657374322e6d6d620000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000010100610020954455354312e6d6d62000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000003303",
"response_sub": 113,
"response_data": "0000000000000000000000"
},
{
"sub": 91,
"request": "41021010005b000030000000000000000000009b03",
"response_sub": 164,
"response_data": "300000000000000000000000000050496e7374616e74656c000600c3f04a00e4194f0074024d4d2f495345452f532f494f00001f603e7657603e76"
},
{
"sub": 71,
"request": "41021010004700ffff000000000000000100005603",
"response_sub": 184,
"response_data": "040000000000000001000000000001"
},
{
"sub": 71,
"request": "41021010004700ffff00000000000000100300005803",
"response_sub": 184,
"response_data": "040000000000000003000000000001"
}
]
}
@@ -0,0 +1,84 @@
{
"source": "bridges/captures/9-24-26 - micromate2/raw_bw_20260924_181942_send_TEST1_to_unit.bin",
"source_sha256": {
"bw": "ad6d47ab8602e1435360fa979d1b4aaf9bbf3bd37ada2f64bafe8c19b7317e18",
"s3": "0fc85cd78df4002d97d9e9a1e6e94d9c1d99bc22935e3b2d1e72a552032c1b84"
},
"unit": "UM12947",
"firmware_version": "11.0CB",
"firmware_line": "blastware",
"exchanges": [
{
"sub": 91,
"request": "41021010005b000030000000000000000000009b03",
"response_sub": 164,
"response_data": "300000000000000000000000000050496e7374616e74656c000600c3f04a00e4194f0074024d4d2f495345452f532f494f00001f603e7657603e76"
},
{
"sub": 65,
"request": "41021010004100ffff000000000000000000004f03",
"response_sub": 190,
"response_data": "ff00000000000000000000556e6976206f6620506974742d3173742059722e20486f7573696e672d4c6f6331205275736b696e2e6d6d6200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 8,
"request": "41021010000800ffff000000000000000000001603",
"response_sub": 247,
"response_data": "5a0000000000000000000000580900000000000000000000000000000000000000000000000000000000000000000000000000000100010001000100000000000000010001000000000000000000000000000000000002000000000000000200000000b42f"
},
{
"sub": 46,
"request": "41021010002e00ffff000000000000000000003c03",
"response_sub": 209,
"response_data": "1c00000000000000000000001ad50000010000000000000000000000000000000000000000141a"
},
{
"sub": 26,
"request": "41021010001a00ffff000000000000000000002803",
"response_sub": 229,
"response_data": "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"
},
{
"sub": 218,
"request": "4102101000da0001000000000000000000000054455354312e6d6d6200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000c603",
"response_sub": 37,
"response_data": "0000000000000000000000"
},
{
"sub": 104,
"request": "41021010006800005a00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000001000100010001000000000000000100010000000000000000000000000000000000100200000000000000100200000000dc03",
"response_sub": 151,
"response_data": "0000000000000000000000"
},
{
"sub": 115,
"request": "41021010007300ffff000000000000000000008103",
"response_sub": 140,
"response_data": "0000000000000000000000"
},
{
"sub": 130,
"request": "41021010008200001c0000000000000000000000000000000100000000000000000000000000000000000000000000af03",
"response_sub": 125,
"response_data": "0000000000000000000000"
},
{
"sub": 131,
"request": "41021010008300ffff000000000000000000009103",
"response_sub": 124,
"response_data": "0000000000000000000000"
},
{
"sub": 113,
"request": "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",
"response_sub": 142,
"response_data": "0000000000000000000000"
},
{
"sub": 114,
"request": "41021010007200ffff000000000000000000008003",
"response_sub": 141,
"response_data": "0000000000000000000000"
}
]
}
@@ -0,0 +1,84 @@
{
"source": "bridges/captures/9-24-26 - micromate2/overwritetest/raw_bw_20260924_185113_test1_overwrite_check.bin",
"source_sha256": {
"bw": "7008231ce9ffadd0f56dfda00cfe030b8721ef928911b72ee58ce11f4ea9146e",
"s3": "d35497ca0ccf554e7bacd464723f3db1c052e2768785ef00b3689784b6e346bd"
},
"unit": "UM12947",
"firmware_version": "11.0CB",
"firmware_line": "blastware",
"exchanges": [
{
"sub": 91,
"request": "41021010005b000030000000000000000000009b03",
"response_sub": 164,
"response_data": "300000000000000000000000000050496e7374616e74656c000600c3f04a00e4194f0074024d4d2f495345452f532f494f00001f603e7657603e76"
},
{
"sub": 65,
"request": "41021010004100ffff000000000000000000004f03",
"response_sub": 190,
"response_data": "ff0000000000000000000054455354312e6d6d62000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000"
},
{
"sub": 8,
"request": "41021010000800ffff000000000000000000001603",
"response_sub": 247,
"response_data": "5a0000000000000000000000580900000000000000000000000000000000000000000000000000000000000000000000000000000100010001000100000000000000010001000000000000000000000000000000000002000000000000000200000000b42f"
},
{
"sub": 46,
"request": "41021010002e00ffff000000000000000000003c03",
"response_sub": 209,
"response_data": "1c00000000000000000000001ad50000010000000000000000000000000000000000000000141a"
},
{
"sub": 26,
"request": "41021010001a00ffff000000000000000000002803",
"response_sub": 229,
"response_data": "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"
},
{
"sub": 218,
"request": "4102101000da0001000000000000000000000054455354312e6d6d6200000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000c603",
"response_sub": 37,
"response_data": "0000000000000000000000"
},
{
"sub": 104,
"request": "41021010006800005a00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000001000100010001000000000000000100010000000000000000000000000000000000100200000000000000100200000000dc03",
"response_sub": 151,
"response_data": "0000000000000000000000"
},
{
"sub": 115,
"request": "41021010007300ffff000000000000000000008103",
"response_sub": 140,
"response_data": "0000000000000000000000"
},
{
"sub": 130,
"request": "41021010008200001c0000000000000000000000000000000100000000000000000000000000000000000000000000af03",
"response_sub": 125,
"response_data": "0000000000000000000000"
},
{
"sub": 131,
"request": "41021010008300ffff000000000000000000009103",
"response_sub": 124,
"response_data": "0000000000000000000000"
},
{
"sub": 113,
"request": "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",
"response_sub": 142,
"response_data": "0000000000000000000000"
},
{
"sub": 114,
"request": "41021010007200ffff000000000000000000008003",
"response_sub": 141,
"response_data": "0000000000000000000000"
}
]
}
Loaded 100 of 184 files, more files were not shown because too many files have changed in this diff. Show more